ML20216A636

From kanterella
Jump to navigation Jump to search
Summary of a Public Meeting with Southern Nuclear Operating Company on July 23, 2020
ML20216A636
Person / Time
Site: Vogtle  
Issue date: 08/10/2020
From: Alina Schiller
NRC/NRR/VPOB
To: Victor Hall
NRC/NRR/VPOB
Alina Schiller EX. 8177
References
Download: ML20216A636 (8)


Text

August 10, 2020 MEMORANDUM TO:

Victor E. Hall, Chief Vogtle Project Office Office of Nuclear Reactor Regulation FROM:

Alina Schiller, Project Manager /RA/

Vogtle Project Office Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF A PUBLIC MEETING WITH SOUTHERN NUCLEAR OPERATING COMPANY ON JULY 23, 2020 The U.S. Nuclear Regulatory Commission (NRC) staff held a Category 1 public meeting with Southern Nuclear Operating Company (SNC) on July 23, 2020. The purpose of the meeting was to discuss the draft revision of the request for alternative regarding requirements for preservice inspection acceptance of volumetric examination flaws for Vogtle Electric Generating Plant (VEGP), Units 3 and 4 (VEGP 3&4-PSI/ISI-ALT-14).

The meeting notice can be found in the Agencywide Documents Access and Management System (ADAMS) Accession No. ML20167A026. The meeting notice is also posted on the NRC public website. Enclosures 1 and 2 are the meeting agenda and attendance list for the meeting, respectively. The draft revision of the request for alternative, referenced during the discussion, can be found at the ADAMS Accession No. ML20203M222.

CONTACT: Alina Schiller, NRR/VPO (301) 415-8177

V. Hall Summary of Meeting:

On July 23, 2020, staff from the NRC conducted a public meeting with representatives from SNC to discuss the draft revision of alternative request VEGP 3&4-PSI/ISI-ALT-14. As previously discussed during the public meeting on July 16, 2020 (ADAMS Accession No. ML20205L431), SNC prepared a draft revision and provided it to NRC for discussion. The draft revision can be found under ADAMS Accession No. ML20203M222. The NRC staff noted that that SNC had made substantial changes to address NRC concerns. The NRC did ask clarifying questions. The NRC staff requested clarification on the table showing the total number of welds of a specific flaw depth. SNC stated that the table shows that the proposed revision is limited to a total of 12 Class 1 welds and 7 Class 2 welds. In addition, only one out of the 12 Class 1 welds can have a flaw depth 55% to 60% through wall and only two out of the 12 Class 1 welds can have a flaw depth 50% to 55% through wall. SNC would provide further clarification on these numbers in the final revised alternative. The NRC staff also asked whether there were currently any welds with a flaw that would exceed 50% or 55% through wall. SNC responded that there are currently no welds with flaws that exceed 55% through wall, although there are flaws that exceed 50% through wall within the limits of the proposed revised alternative request.

Finally, the NRC staff asked how SNC would address multiple flaws up to 60% through wall in one weld. SNC stated that they would include additional information for addressing for multiple flaws, including the use of proximity rules in Section XI of the American Society of Mechanical Engineers Boiler and Pressure Vessel (ASME B&PV), where two adjacent flaws within the proximity limits would be bounded by a single flaw encompassing the multiple flaws to be conservative.

NRC staff concluded that the revisions SNC made to the alternative request would enable staff to complete the review and that a request for additional information would no longer be needed.

Based on discussions, SNC stated they would submit the revision of the request for alternative VEGP 3&4-PSI/ISI-ALT-14 as soon as possible.

At the conclusion of the discussion, there was an opportunity for the public to provide comments and ask questions. There were no comments or questions from the public.

Docket Nos.: 52-025 52-026

Enclosures:

As stated cc w/encls: See next page

ML20216A636

  • via e-mail NRC-001 OFFICE PM: NRR/VPO LA: NRR/VPO PM: NRR/VPO BC: NRR/VPO NAME ASchiller* (c)

RButler*

CSantos*

VHall*

DATE 8/4/20 8/4/20 8/7/20 8/10/20 OFFICE PM: NRR/VPO NAME ASchiller (s)

DATE 8/10/20

AGENDA FOR PUBLIC MEETING U.S. NUCLEAR REGULATORY COMMISSION (NRC)

Thursday, July 23, 2020 Teleconference 9:00 a.m. - 12:00 p.m.

PURPOSE:

To discuss issues associated with the safety review of licensing actions for Southern Nuclear Operating Companys (SNC) Vogtle Electric Generating Plant (VEGP) Units 3 and 4.

OPEN Time Topic Led By 9:00 a.m.

Opening Remarks NRC 9:10 a.m.

Discussion of Identified Topics NRC/SNC Opportunity for Public Comment Open Portion Concludes NRC/Public CLOSED 12:00 p.m.

(If needed)

Adjourn NRC/SNC

PUBLIC MEETING U.S. NUCLEAR REGULATORY COMMISSION Thursday, July 23, 2020 Teleconference 9:00 a.m. - 12:00 p.m.

List of Attendees Name Organization Representing the Nuclear Regulatory Commission Mike King Billy Gleaves Omar Lopez-Santiago Christopher Welch James Gaslevic Cayetano Santos Alina Schiller NRR/VPO Matthew Mitchell John Honcharik Robert Caldwell NRR/DNRL Stephen Smith NRR/DSS Robert Taylor NRR Nicole Coovert Patrick Heher Brendan Collins Region II Representing Industry Kelli Roberts Curtis Castell Amy Chamberlain Kyle Caver Mark Humphrey Justin Sciulli Stephanie Agee Warren Bamford Jason Hurst Mark Wilson Nathan Chapman Adam Quarles Ken Beatty Anees Udyawar Southern Nuclear Operating Company Westinghouse Electric Company Representing Public Yan Peng China Institute of Atomic Energy Note: All participated via teleconference.

Enclosure 2

Vogtle Mailing List (Revised 4/7/2020) cc:

Resident Manager Resident Inspector Oglethorpe Power Corporation Vogtle Plant Units 3 & 4 Alvin W. Vogtle Nuclear Plant 8805 River Road 7821 River Road Waynesboro, GA 30830 Waynesboro, GA 30830 Mr. Barty Simonton Office of the Attorney General Team Leader 40 Capitol Square, SW Environmental Radiation Program Atlanta, GA 30334 Air Protection Branch Environmental Protection Division Southern Nuclear Operating Company 4244 International Parkway, Suite 120 Document Control Coordinator Atlanta, GA 30354-3906 3535 Colonnade Parkway Birmingham, AL 35243 Brian H. Whitley Regulatory Affairs Director Anne F. Appleby Southern Nuclear Operating Company Olgethorpe Power Corporation 3535 Colonnade Parkway, BIN N-226-EC 2100 East Exchange Place Birmingham, AL 35243 Tucker, GA 30084 Mr. Michael Yox County Commissioner Site Regulatory Affairs Director Office of the County Commissioner Vogtle Units 3 & 4 Burke County Commission 7825 River Road, Building 302 (ESB)

Waynesboro, GA 30830 Bin 6031 Waynesboro, GA 30830 Mr. Wayne Guilfoyle Commissioner District 8 Augusta-Richmond County Commission 4940 Windsor Spring Rd Hephzibah, GA 30815 Gwendolyn Jackson Burke County Library 130 Highway 24 South Waynesboro, GA 30830 Mr. Reece McAlister Executive Secretary Georgia Public Service Commission Atlanta, GA 30334 Page 1 of 3

Vogtle Mailing List Email aagibson@southernco.com (Amanda Gibson) acchambe@southernco.com (Amy Chamberlian) gam@nei.org (Gia Montserrat)

Lindsay@georgiawand.org (Lindsay Harper) bhwhitley@southernco.com (Brian Whitley)

Bill.Jacobs@gdsassociates.com (Bill Jacobs) corletmm@westinghouse.com (Michael M. Corletti) crpierce@southernco.com (C.R. Pierce) dahjones@southernco.com (David Jones) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis) dlfulton@southernco.com (Dale Fulton) ed.burns@earthlink.net (Ed Burns) edavis@pegasusgroup.us (Ed David)

G2NDRMDC@southernco.com (SNC Document Control)

George.Taylor@opc.com (George Taylor) harperzs@westinghouse.com (Zachary S. Harper) james1.beard@ge.com (James Beard)

JHaswell@southernco.com (Jeremiah Haswell) jim@ncwarn.org (Jim Warren)

John.Bozga@nrc.gov (John Bozga)

Joseph_Hegner@dom.com (Joseph Hegner) karlg@att.net (Karl Gross) kmstacy@southernco.com (Kara Stacy) kroberts@southernco.com (Kelli Roberts)

KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) markus.popa@hq.doe.gov (Markus Popa) mdmeier@southernco.com (Mike Meier) media@nei.org (Scott Peterson)

Melissa.Smith@Hq.Doe.Gov (Melissa Smith) mike.price@opc.com (M.W. Price)

MKWASHIN@southernco.com (MKWashington) mphumphr@southernco.com (Mark Humphrey)

MSF@nei.org (Marvin Fertel) nirsnet@nirs.org (Michael Mariotte)

Nuclaw@mindspring.com (Robert Temple)

Paul@beyondnuclear.org (Paul Gunter) pbessette@morganlewis.com (Paul Bessette) ppsena@southernco.com (Peter Sena,III) r.joshi15@comcast.net (Ravi Joshi) rwink@ameren.com (Roger Wink) sabinski@suddenlink.net (Steve A. Bennett)

Michelle@cleanenergy.org (Michelle Powell)

Page 2 of 3

Vogtle Mailing List sblanton@balch.com (Stanford Blanton)

Shiva.Granmayeh@hq.doe.gov (Shiva Granmayeh) sjackson@meagpower.org (Steven Jackson) sjones@psc.state.ga.us (Shemetha Jones) skauffman@mpr.com (Storm Kauffman) slieghty@southernco.com (Steve Leighty) sroetger@psc.state.ga.us (Steve Roetger) syagee@southernco.com (Stephanie Agee)

TomClements329@cs.com (Tom Clements)

Vanessa.quinn@dhs.gov (Vanessa Quinn) vcsummer2n3@gmail.com (Brian McIntyre) wayne.marquino@gmail.com (Wayne Marquino) weave1dw@westinghouse.com (Doug Weaver)

William.Birge@hq.doe.gov (William Birge)

X2edgran@southernco.com (Eddie R. Grant)

X2hagge@southern.com (Neil Haggerty)

X2dwwill@southernco.com (Daniel Williamson)

Page 3 of 3