April 24, 2018 MEMORANDUM TO: Samuel S. Lee, Chief Licensing Branch 1 Division of New Reactor Licensing Office of New Reactors FROM: Omid Tabatabai, Senior Project Manager /RA/

Licensing Branch 1 Division of New Reactor Licensing Office of New Reactors

SUBJECT:

SUMMARY

OF THE APRIL 10, 2018, PUBLIC MEETING WITH NUSCALE POWER, LLC, TO DISCUSS U.S. NUCLEAR REGULATORY COMMISSION STAFFS REQUESTS FOR ADDITIONAL INFORMATION AND NUSCALES APPROACH TO PIPE BREAK ANALYSIS On April 10, 2018, representatives of the U.S. Nuclear Regulatory Commission (NRC) and NuScale Power, LLC (NuScale) held a public teleconference meeting to discuss staffs questions regarding NuScales approach to pipe break analysis as well as the status of NuScales response to staffs requests for additional information (RAI). The NRC staffs RAIs are publicly available in Agencywide Documents Access and Management System (ADAMS) under Accession Nos. ML17335A111 (RAI 9221) and ML17153A065 (RAI 8836) respectively. captures the summary of the topics discussed during the teleconference. The agenda and list of meeting attendees are included in Enclosures 2 and 3, respectively. The meeting notice for this meeting is available in ADAMS under Accession No. ML18047A108.

Docket No.52-048

Enclosures:

1. Meeting Summary
2. Agenda
3. Attendees CONTACT: Omid Tabatabai, NRO/DNRL 301-415-6616

ML18113A104 *via email NRC-001 OFFICE NRO/DNRL/LB1: PM NRO/DNRL/LB1: LA* NRO/DEI/MEB : BC* NRO/DNRL/LB1: PM NAME OTabatabai MMoore TLupold OTabatabai DATE 4/24/2018 4/23/2018 4/24/2018 4/24/2018 U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE APRIL 10, 2018, TELECONFERENCE WITH NUSCALE POWER, LLC TO DISCUSS NUSCALES APPROACH TO PIPE BREAK ANALYSIS AND STAFFS REQUEST FOR ADDITIONAL INFORMATION The U.S. Nuclear Regulatory Commission (NRC) staff requested this public meeting to discuss staffs questions related to NuScales approach to pipe break analysis. The NRC staffs request for additional information (RAI) are publicly available in Agencywide Documents Access and Management System (ADAMS) under Accession Nos. ML17335A111 (RAI 9221) and ML17153A065 (RAI 8836). The majority of the discussions between the NRC staff and NuScale contained proprietary information and were closed to the public.

During the open and closed portions of the meeting NuScale summarized the discussions and actions from the November 2017 meeting and provided a status on the action items. NuScale provided an overview of its approach to analyzing various postulated pipe breaks based on the location and environment. NuScale also described how the following events are considered in their overall pipe break analysis:

  • Blasts,
  • Pipe whip,
  • Jet impingement,
  • Subcompartment pressurization, and
  • Flooding.

NuScale informed the NRC staff that the target date for submitting its responses to RAIs 8836 and 9221 is August 24, 2018.

Enclosure 1

U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE APRIL 10, 2018, TELECONFERENCE WITH NUSCALE POWER, LLC MEETING AGENDA 1:00 - 1:10 Meeting Introductions NuScale/NRC 1:10 - 1:45 Pipe Break Analysis and Staff RAIs NuScale/NRC 1:45 - 1:55 Questions from the public Public 1:55 - 2:00 Break (end of public portion of the meeting) 2:00 - 2:55 Pipe Break Analysis and Staff RAIs NuScale/NRC 2:55 - 3:00 Meeting Conclusion NRC Enclosure 2

U.S. NUCLEAR REGULATORY COMMISSION

SUMMARY

OF THE APRIL 10, 2018, TELECONFERENCE WITH NUSCALE POWER, LLC LIST OF ATTENDEES NuScale Power, LLC JJ Arthur Storm Kauffman Daniel Diefendorf Nadja Paulman Marty Bryan Marwan Charrouf Wayne Massie U.S. Nuclear Regulatory Commission Staff Omid Tabatabai Renee Li Chang Li Clint Ashley Antonio Dias Tim Lupold Raul Hernandez Greg Cranston Eric Reichelt Jason Huang Other Attendees (Public Session)

Sarah Fields (Uranium Watch)

Enclosure 3