September 23, 2019 MEMORANDUM TO:

Samuel S. Lee, Chief Licensing Branch 1 Division of Licensing, Siting, and Environmental Analysis Office of New Reactors FROM:

Cayetano Santos, Jr., Project Manager /RA/

Licensing Branch 1 Division of Licensing, Siting, and Environmental Analysis Office of New Reactors

SUBJECT:

SUMMARY

OF THE SEPTEMBER 4, 2019, PUBLIC TELECONFERENCE REGARDING THE INSPECTIONS, TESTS, ANALYSES, AND ACCEPTANCE CRITERIA IN NUSCALE POWER, LLCS DESIGN CERTIFICATION APPLICATION On September 4, 2019, a Category 1 public teleconference was held between the U.S. Nuclear Regulatory Commission (NRC) staff and NuScale Power, LLC (NuScale). The purpose of the meeting was to discuss proposed inspections, tests, analyses and acceptance criteria described in NuScales design certification application.

The meeting notice was posted on the NRC website and is also in the NRCs Agencywide Documents Access and Management System under Accession Number ML19217A096. The Meeting Summary is provided as Enclosure 1, which captures the summary of topics discussed.

The Meeting Agenda and List of Attendees are provided as Enclosures 2 and 3, respectively.

Docket No.52-048

Enclosures:

1. Meeting Summary
2. Meeting Agenda
3. List of Attendees cc w/encl: DC NuScale Power, LLC Listserv CONTACT: Cayetano Santos, Jr., NRO/DLSE 301-415-7270

ML19260G538

  • via email NRO-002 OFFICE DLSE/LB1: PM DLSE/LB1: LA DLSE/LB1: PM NAME CSantos MMoore*

CSantos (signed)

DATE 09/23/2019 09/20/2019 09/23/2019

U.S. NUCLEAR REGULATORY COMMISSION PROPOSED INSPECTIONS, TESTS, ANALYSES, AND ACCEPTANCE CRITERIA MEETING

SUMMARY

September 4, 2019 In response to Request for Additional Information (RAI) No. 9681 dated July 19, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19200A248), NuScale Power, LLC (NuScale), proposed relocating the following inspections, tests, analyses, and acceptance criteria (ITAAC) from Design Certification Application (DCA),

Tier 1, Chapter 2, Unit Specific Structures, Systems, and Components Design Descriptions and Inspections, Tests, Analyses, and Acceptance Criteria, to Tier 1, Chapter 3, Shared Structures, Systems, and Components and Non-Structures, Systems, and Components Design Descriptions and Inspections, Tests, Analyses, and Acceptance Criteria.

1. ITAAC #22 from Table 2.1-4 was relocated to ITAAC #4 in Table 3.14-2
2. ITAAC #3 from Table 2.8-2 was relocated to ITAAC #5 in Table 3.14-2
3. ITAAC #5 from Table 2.8-2 was relocated to ITAAC #6 in Table 3.14-2
4. ITAAC #6 from Table 2.8-2 was relocated to ITAAC #7 in Table 3.14-2
5. ITAAC #8 from Table 2.8-2 was relocated to ITAAC #8 in Table 3.14-2 The U.S. Nuclear Regulatory Commission (NRC) staff asked NuScale to explain the basis for these changes. NuScale stated that these five ITAAC meet the Tier 1 definition of Common or Shared ITAAC so NuScale proposed to relocate them to Tier 1, Section 3.14. With respect to ITAAC #6, the staff discussed the provisions for valve qualification in the American Society of Mechanical Engineers (ASME) Standard QME-1-2007, Qualification of Active Mechanical Equipment Used in Nuclear Power Plants, which is addressed by the Qualification Report specified in the ITAAC with more detail in Tier 2 of the DCA Part 2. Per this standard, the staff indicated that all safety-related valves are required by the ITAAC and Tier 2 to satisfy ASME Standard QME-1-2007, although different levels of testing may be applied to the first valve and all subsequent valves. Upon consideration of this information, NuScale indicated that these five ITAAC will be moved back to their original location in Tier 1, Chapter 2.

There was an opportunity for members of the public to provide comments and ask questions.

No comments or questions were received.

U.S. NUCLEAR REGULATORY COMMISSION PROPOSED INSPECTIONS, TESTS, ANALYSES, AND ACCEPTANCE CRITERIA MEETING AGENDA September 4, 2019 12:00 p.m. - 1:00 p.m.

The purpose of this teleconference was for the U.S. Nuclear Regulatory Commission (NRC) and NuScale Power, LLC, (NuScale) to discuss proposed inspections, tests, analyses, and acceptance criteria (ITAAC).

Time Topic Speaker 12:00 p.m. - 12:05 p.m.

Introductions

All 12:05 p.m. - 12:45 p.m.

Proposed ITAAC NRC/NuScale 12:45 p.m. - 1:00 p.m.

Public Comments Public 1:00 p.m.

Adjourn All

U.S. NUCLEAR REGULATORY COMMISSION PROPOSED INSPECTIONS, TESTS, ANALYSES, AND ACCEPTANCE CRITERIA LIST OF ATTENDEES September 4, 2019 12:00 p.m. - 1:00 p.m.

Name Organization Cayetano Santos U.S. Nuclear Regulatory Commission (NRC)

Nicholas Hansing NRC Nadim Khan NRC Sheila Ray NRC John Budzynski NRC Alexandra Siwy NRC Clinton Ashley NRC Thomas Scarbrough NRC Nadja Joergensen NuScale Power, LLC (NuScale)

Chris Maxwell NuScale Edan Engstrom NuScale Spain Abney NuScale Dustin Greenwood NuScale