Hematite Decommissioning Project Procedure HDP-PR-HP-311, Radiolo l

FORM HDP-PR-HP-311-3 Revision 1 I

I RADIOLOGICAL SURVEY REPORT - WALKOVER SURVEYS SURVEY LOCATION:

LSA 10-05 DATE:

1/ 18/2014 TIME:

8:00 RWP:

RP-14-G009 LOG NUMBER:

0179 C 140119 PURPOSE OF SURVEY: Manual GWS ofLSA 10-05 Side Walls for FSS Serial Number Cal Due Date:

Back2;round Efficiency(%)

Instrument Tvnes{s)

{meter/detector)

(meter-detector)

(CPM a/lw)

(af6'Y)

Lud 2221 44-10 DD 299540 I PR 321895 7/3/2014 3,972 NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA NIA REMARKS:

Perfonned Manual GWS of LSA I 0-05 Side Walls.

All readings given in gcpm.

See attached map for locatios surveyed.

General area background was 12,000 gcpm.

Maximum reading while perfonning GWS was 14,865 gcpm.

TECHNIC!AN(S):

( -t;..u~ c ~11/p( k,,, ~]uL J.. J!.;/</

Print Name/Sign/DP' REVIEWER:

Print Name/Sign/Date

I

~-.-1 E /s FSS N

\\