ML18010A282

From kanterella
Jump to navigation Jump to search
Final Status Survey Final Report Volume 3, Chapter 6, Survey Area Release Record for Land Survey Area 10, Analytical Report: 160-5228-2
ML18010A282
Person / Time
Site: 07000036
(SNM-0033)
Issue date: 12/13/2017
From: Swanson M, Vania I
TestAmerica Labs - St. Louis, Westinghouse
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18010A247 List: ... further results
References
160-5228-2, HEM-17-72
Download: ML18010A282 (29)


Text

ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-5228-2 Client Project/Site: RFP-CBA-022 (21 DAY TAT)

For:

Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:

2/21/2014 11:24:30 AM Ivan Vania, Project Manager II (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT)

TestAmerica Job ID: 160-5228-2 Page 2 of 29 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

9 Definitions/Glossary.......................................

10 Method Summary.........................................

11 Sample Summary.........................................

12 Client Sample Results......................................

13 QC Sample Results........................................

26 QC Association Summary...................................

28 1

2 3

4 5

6 7

8 9

10 11

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-5228-2 Project/Site: RFP-CBA-022 (21 DAY TAT)

Job ID: 160-5228-2 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (21 DAY TAT)

Report Number: 160-5228-2 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 01/20/2014; the samples arrived in good condition, properly preserved and on ice. The temperatures of the 2 coolers at receipt time were 18.0º C and 18.0º C.

RADIUM-226 BY GAMMA SPEC (21 DAY INGROWTH)

Samples L100525BUB00 (160-5228-1), L100526BUB00 (160-5228-2), L100527BUB00 (160-5228-3), L100528BUB00 (160-5228-4),

L100501BES00 (160-5228-5), L100502BEQ00 (160-5228-6), L100502BES00 (160-5228-7), L100503BES00 (160-5228-8),

L100504BES00 (160-5228-9), L100505BES00 (160-5228-10), L100506BES00 (160-5228-11), L100507BES00 (160-5228-12),

L100508BES00 (160-5228-13), L100509BSS00 (160-5228-14), L100510BSS00 (160-5228-15), L100511BSS00 (160-5228-16),

L100512BSS00 (160-5228-17), L100513BSS00 (160-5228-18), L100514BSS00 (160-5228-19), L100515BSS00 (160-5228-20),

L100516BSS00 (160-5228-21), L100517BSS00 (160-5228-22), L100518BSS00 (160-5228-23), L100519BSS00 (160-5228-24),

L100520BSS00 (160-5228-25), L100521BSS00 (160-5228-26), L100522BSS00 (160-5228-27), L100523BSS00 (160-5228-28) and L100524BSS00 (160-5228-29) were analyzed for Radium-226 by gamma spec (21 day ingrowth) in accordance with EPA GA_01_R. The samples were leached on 01/21/2014, prepared on 01/23/2014 and analyzed on 02/13/2014 and 02/18/2014.

TestAmerica St. Louis Page 3 of 29 1

2 3

4 5

6 7

8 9

10 11

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-5228-2 Project/Site: RFP-CBA-022 (21 DAY TAT)

Job ID: 160-5228-2 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

No difficulties were encountered during the Radium 226 analysis. All other quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 4 of 29 1

2 3

4 5

6 7

8 9

10 11

Page 5 of 29 1

2 3

4 5

6 7

8 9

10 11

!Procedure HDP-PR-QA-006, Chain of Custody Page 1 ofl Hematite Decommissioning Project §"evision: 3 I

I Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed Coe to HDP.

Chain ofCutody ID No. I F-011914-02 Pa2e Project Name:

Westinghouse Electric Company Contact Person:

Gerald Rood Phone Number; 314-810-3382 Sampler Name Scott Jenkins 1/1

~

~f' c3 :*

~ '

0 R.equeste:d Aaiifysisi.

,....._ t'_.,,.*d Pf-;"

~ *-":

N

~

~

~

61*

. SI

~

-0 8

. 2

~r~~I

§ 0

8.

s,..,

0. \\'*

""ls-am-pl_e_lD _______

~ID_a_t_e ____

....,..IT_im_e ~I-M-atnx

- -~1 ~ i ::~5 i ti<

~ ~

;, C, fut;,

Ll00525BUBOO 1/19/2014 I 12:50 L100526BUBOO 1/19/2014 I 13:oo L100527BUBOO l/19/2014 I 13:10 L100528BUBOO 1/19/2014 I 13:15 Relinquished be:::::._:

. Date_ /Ti?e J-;}...o...,

1u1 Company Name: we.c..--

Received by:

Date/Time Company Name:

Relinquished by:

Date/Time Company Name:

s CI; ':Y XIX,.

I, s

s s

c ~

i;:"

-,,I C I\\,.'"'"!.*:,

Cl~~'

L;., "'j

~

I~~~=

kX IX X1X

,~XI X

.I L

I:*~~,*

1*.a; l

l~~I Da~rrne

,,l\\ \\:!' 7

~

Name:JI roao>'

Do/Time

\\"i \\it°'

Date?rrne r/v-t_l{

1Co~Name:

r"&~

Total

.4_

Laboratory Name:

ITA-MO Laboratory Address, 13715 Rider Trail North t o:t---------------------1

-~ PhoneNo.

8 314-298-8566

'E Laboratory Contact Person:

~ Joe Walker Phone No.

708-870-8453_

Turn Around Time Rush (7 days)

Remarks 1 ILSA-10-05 Bias Samples 1 ILSA-10-05 Bias Samples 1 ILSA-10-05 Bias Samples 1 ILSA-10-05 Bias Samples Cooler Temperature:

AmhiP.nt Cooler ID: I Shipper and Number:

_OJ 20-=1l4 Comments: Please analyze samples on a 7 day TAT for Tc-99.

Please analyze samples for gamma spec after a 21 day ingrowth period.

iVc'B" _ C....-1+1 Wi IJj-<,

~

f'i ti oG

- - ---------~ --- -----:---:--:----~~~: *-----

Page 6 of 29 1

2 3

4 5

6 7

8 9

10 11 Procedure HDP-PR-QA-006, Chain of Custody Hematite Decommissioning I>roject Revision: 3 I

Page 1 ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time 1he container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify 1hat the sample is correctly identified before 1he sample is released for use or analysis and send the completed CoC to HDP.

Chain of Cutodv ID No.

F-011914-01 Pae:e 1/3

,. *..,,,,. Reciii~te.d::Mfalv.s1s

  • Laboratorv Name:

Project Name:

. *~.}~

I' 11 Fl

( ! 1("?

TA-MO Westinghouse Electric Company

,J\\,. r Contact Person:

},,.

[~

C

+~

Laboratory Address:

f'.i fi r't1tf Gerald Rood c8 13715 Rider Trail North j

~

r, *:.,.;

~ "

0

,a Phone Number:

~:,{,1;1(

-~

,...cr:,

  • --* *s Phone No.

314-810-3382

,a f~1 0

314-298-8566

~ ;-....

u Sampler Name ii I

~ Laboratory Contact Person:

  • .) "O 0

Scott Jenkins a -

E--

Joe Walker

.2 N

r\\;

Phone No_

§ 0

~

~ ;:i,.

) 708-870-8453 .**. rn I Turn Around Time Q i~ 0 ~Jii a

  • a

.i ~ Rush (7 days) c..

  • B

§ Sample ID Date Time Matrix E 0

'B Remarks 8

,:!l C;J u***** L100501BESOO 1/16/2014 8:55 s C

  • -,.,:~

X X

  • i

(... 1 LSA-10-05 Sys samples L100502BEQOO 1/16/2014 9:15 s C

  • c:r.

i:X X i 1 LSA-10-05 QC samples L100502BESOO 1/16/2014 9:15 s C rn-.;.fa X. X 1 LSA-10-05 Sys samples L100503BESOO 1/14/2014 11:05 s C ?{y~ X

  • x 1 LSA-10-05 Sys samples L100504BESOO 1/14/2014 14:20 s

C *Jt:*' X

  • x 1 LSA-10-05 Sys samples L100505BESOO 1/14/2014 10:50 s C

1 1','}1~

x x,

1 LSA-10-05 Sys samples L100506BESOO 1/14/2014 14:00 s C X X 1 LSA-10-05 Sys samples Ll00507BESOO 1/14/2014 14:15 s C l'T~'%,\\: X X 1 LSA-10-05 Sys samples L100508BESOO 1/14/2014 10:35 s C ~; X X 1 LSA-10-05 Sys samples L100509BSSOO 1/17/2014 14:30 s C i'l\\~ X X 1 LSA-10-05 Sidewall Samples L100510BSSOO 1/17/2014 11:10 s C >i~i ,X x l 1 LSA-10-05 Sidewall Samples L10051IBSSOO 1/17/2014 10:45 s C

    • - C;~*,'

X X 1 LSA-10-05 Sidewall Samples Relinquished b'("" _;_..!:,,,- ~ Date/Tim~ ~"l: /'J/J. Date/Time Total Cooler Temperature: 9,.0" \\ "NT .A. o,_4 0 ')<; Amhient ./t ~~ Company-Name: \\A),..... < l<'.;ompany~ Cooler ID: Shipper and Number: r....L.----" I Jl/'1/ o.ciss, \\ 0 1 ?.OJH /04 Received by: Date/Time Relin~ishe<P')'iJ,,,. Date/Time Comments: Please analyze samples on a 7 TAT for Tc-99. 1/-J.,,,z, * ~,.. , a,....._;,,.1-~i~ Please analyze samples for gamma spec after a 21 day ingrowth Company Name: .Company Name: period. /">'(°"'A.~'(',.,<:::) c\\ <; Relinquished by: Date/Time Re~ Date0e VerifiedBy: tv-c-J~..S Lu~ L &-.v,- t/2.;; ti/ Company Name: Colllf.fl-Y Name: cin L.

Page 7 of 29 1 2 3 4 5 6 7 8 9 10 11 Procedure 8DP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I Pagel ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP. Chain of Cutodv ID No. F-011914-01 Paee 2/3 ..,.. i\\,. .. ReanestedAnal"vsis-Laboratorv Name: Project Name: [~

  • 1;v G',!\\! ~:

~;i;-~ [;~ TA-MO Westinghouse Electric Company ~ ffi fl ~ Contact Person: ~ >' ~f Laboratory Address: Gerald Rood

f ii '8

\\.,'. ",. 13715 Rider Trail North ~ L*t,,.. ~ 0 tJ

f;;;

,,,... C Phone Number: fl), 5b :;;': ".§ Phone No. 314-810-3382 .s 11,. C 314-298-8566 1;:{.

  • ' 8 Sampler Name

~

/'

~ Laboratory Contact Person: ~ \\+:{~;:) -0 r,t~. Scott Jenkins s .... I l/"1-,, ~ Joe Walker

l N

.§ !fg II Phone No. ~ () 0 (\\) I 708-870-8453

3 ii.

c.. 0 [fl Turn Around Time ~,,. () t~ o:I i ~I

  • a s

t;. Rush (7 days) .8 § -~@ Sample ID Date Time Matrix 0 r,;;!E f~, Remarks 8 ti, ~ c::, L100512BSSOO 1/17/2014 10:50 s C (Gf X X 1 LSA-10-05 Sidewall Samples L100513BSSOO 1/17/2014 14:20 s C \\\\ ,X X 1 LSA-10-05 Sidewall Samples L100514BSSOO 1/17/2014 13:50 s C (,.. X. X 1 LSA-10-05 Sidewall Samples L100515BSSOO 1/17/2014 14:10 s C

  • x X *,.

1 LSA-10-05 Sidewall Samples

j.

L100516BSSOO 1/17/2014 11:00 s C . ? X X 1 LSA-10-05 Sidewall Samples L1005 l 7BSSOO 1/16/2014 15:35 s C X X, 1 LSA-10-05 Sidewall Samples Ll00518BSSOO 1/16/2014 15:10 s C ~ - X 1 LSA-10-05 Sidewall Samples L1005 l 9BSSOO 1/17/2014 14:55 s C X X 1 LSA-10-05 Sidewall Samples L100520BSSOO 1/17/2014 14:45 s C c.. rx X (. 1 LSA-10-05 Sidewall Samples L100521BSSOO 1/16/2014 14:15 s C X X 1 LSA-10-05 Sidewall Samples Ll 00522BSSOO 1/16/2014 14:20 s C X X 1 LSA-10-05 Sidewall Samples Ll 00523BSSOO 1/16/2014 14:35 s C,...., .::X X l LSA-10-05 Sidewall Samples Relinquished r =- J-Date/Tim'-\\ ~by: r1/J~..- Date/Time Total Cooler Temperature: 9-0"' \\ \\'1...,0 \\'-7 ?"i Aml-.ie,nt Company Name: \\.l)f/1 - \\',{ 5' Company Name: Cooler ID: Shipper and Number: I I>/ Cvoss.--c,a&-5 \\ le 0120-0,/0tl Received by: Date/Time ~!n~~~~~- Date/Time Comments: Please analyze samples on a 7 TAT for Tc-99. 0 ~ Please analyze samples for gamma spec after a 21 day ingrowth Company Name: Company ~~e: \\"'(JJ \\(? period. C'<'c:::%"'o 4 W~l~r Relinquished by: Date/Time Rec~ D/t/Iime C:.)>,..,~;- ~ l 2.P{'( Verified By: Company Name: Company Name: {; rt:t C ~

Page 8 of 29 1 2 3 4 5 6 7 8 9 10 11 Procedure HDP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I Page 1 ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the CoC The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP. Chain of Cutodv ID No. F-011914-01 Pa!!e 3/3 R).()Jlci;ted.~alvsrs. Laboratorv Name: Project Name: r'cc-

oc i;*; I TA-MO 11

'D

  • ~

N

.*/1 Westinghouse Electric Company N ;:f>.

Contact Person: ~;l~ ~ ij ~) i:li.. Laboratory Address:

r,\\t;

'8 ,/ 4, Gerald Rood it 13715 Rider Trail North

\\
:::

c' ['; 'c

~

~ .i ~ Phone Number: tit f . -rg Phone No. f h 314-810-3382

tiF/

t,. 8 314-298-8566 Sampler Name ~ ?t t*~ "i'l Laboratory Contact Person: -0 Scott Jenkins s E ,'{fy~ ~ Joe Walker e

l

~ I?( Phone No. ,~ . § :**%: (.) 0 (l) ,~, 708-870-8453 ~

i

!J P. 0 CZl

1 Turn Around Time Q

(.) ro [~:t t>

  • 5.

E Rush (7 days)

0.

2 § Sample ID Date Time Matrix 8 0 0 ~ 0 + Remarks u 1.- Ll 00524BSSOO 1/16/2014 15:00 s C *"'* 'X X 1 LSA-10"05 Sidewall Samples .3!1~: )] ~1 *;;:. \\,i,,i ~ I* *.. : ' imtt',* l*_,;c Relinauishedf y: Date/Time ~i~y~~ Date/Time Total Cooler Temperature: _;,;- ~,-o, li 0 ?." AmhiP.n-t Company Nmne: ,'6,.-[ l-r itJ,Y Company Name-: \\'v \\Co,'? Cooler ID: Shipper and Number: vO c('~,c,oao5 0120-fn/04 Received by: Date/Time Relinquished~ ('J_ Date/Time Comments: Please analyze samples on a 7 TAT forTc-99. 2-),,.,h~.*= '\\. OtS;A. Please analyze samples for gamma spec after a21 day ingrowth Company Name: Company~~: \\,.2, \\<f? period. CYo~5m' C.-.. Relinquished by: Date/Time Rece~ Date/Time C: (,t. I"',l;t -Wi \\J,µ-- t {u/1¥ VerifiedB~ Company Name: Comp~Name: clJ,1


~~~~~~~~---*!-----

Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-5228-2 Login Number: 5228 Question Answer Comment Creator: Daniels, Brian J List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter. True The cooler's custody seal, if present, is intact. N/A Sample custody seals, if present, are intact. True The cooler or samples do not appear to have been compromised or tampered with. False Samples were received on ice. True Cooler Temperature is acceptable. True Cooler Temperature is recorded. True COC is present. True COC is filled out in ink and legible. True COC is filled out with all pertinent information. True Is the Field Sampler's name present on COC? True There are no discrepancies between the containers received and the COC. True Samples are received within Holding Time. True Sample containers have legible labels. True Containers are not broken or leaking. True Sample collection date/times are provided. True Appropriate sample containers are used. True Sample bottles are completely filled. True Sample Preservation Verified. True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is <6mm (1/4"). True Multiphasic samples are not present. True Samples do not require splitting or compositing. N/A Residual Chlorine Checked. TestAmerica St. Louis Page 9 of 29 1 2 3 4 5 6 7 8 9 10 11

Definitions/Glossary TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Qualifiers Rad Qualifier Description U Result is less than the sample detection limit. Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation %R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference) Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin) NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown) PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry) RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin) TEQ Toxicity Equivalent Quotient (Dioxin) TestAmerica St. Louis Page 10 of 29 1 2 3 4 5 6 7 8 9 10 11

Method Summary TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Method Method Description Laboratory Protocol DOE GA-01-R Radium-226 & Other Gamma Emitters (GS) TAL SL Protocol

References:

DOE = U.S. Department of Energy Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 11 of 29 1 2 3 4 5 6 7 8 9 10 11

Sample Summary TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID Client Sample ID Received Collected Matrix 160-5228-1 L100525BUB00 Solid 01/19/14 12:50 01/20/14 18:30 160-5228-2 L100526BUB00 Solid 01/19/14 13:00 01/20/14 18:30 160-5228-3 L100527BUB00 Solid 01/19/14 13:10 01/20/14 18:30 160-5228-4 L100528BUB00 Solid 01/19/14 13:15 01/20/14 18:30 160-5228-5 L100501BES00 Solid 01/16/14 08:55 01/20/14 18:30 160-5228-6 L100502BEQ00 Solid 01/16/14 09:15 01/20/14 18:30 160-5228-7 L100502BES00 Solid 01/16/14 09:15 01/20/14 18:30 160-5228-8 L100503BES00 Solid 01/14/14 11:05 01/20/14 18:30 160-5228-9 L100504BES00 Solid 01/14/14 14:20 01/20/14 18:30 160-5228-10 L100505BES00 Solid 01/14/14 10:50 01/20/14 18:30 160-5228-11 L100506BES00 Solid 01/14/14 14:00 01/20/14 18:30 160-5228-12 L100507BES00 Solid 01/14/14 14:15 01/20/14 18:30 160-5228-13 L100508BES00 Solid 01/14/14 10:35 01/20/14 18:30 160-5228-14 L100509BSS00 Solid 01/17/14 14:30 01/20/14 18:30 160-5228-15 L100510BSS00 Solid 01/17/14 11:10 01/20/14 18:30 160-5228-16 L100511BSS00 Solid 01/17/14 10:45 01/20/14 18:30 160-5228-17 L100512BSS00 Solid 01/17/14 10:50 01/20/14 18:30 160-5228-18 L100513BSS00 Solid 01/17/14 14:20 01/20/14 18:30 160-5228-19 L100514BSS00 Solid 01/17/14 13:50 01/20/14 18:30 160-5228-20 L100515BSS00 Solid 01/17/14 14:10 01/20/14 18:30 160-5228-21 L100516BSS00 Solid 01/17/14 11:00 01/20/14 18:30 160-5228-22 L100517BSS00 Solid 01/16/14 15:35 01/20/14 18:30 160-5228-23 L100518BSS00 Solid 01/16/14 15:10 01/20/14 18:30 160-5228-24 L100519BSS00 Solid 01/17/14 14:55 01/20/14 18:30 160-5228-25 L100520BSS00 Solid 01/17/14 14:45 01/20/14 18:30 160-5228-26 L100521BSS00 Solid 01/16/14 14:15 01/20/14 18:30 160-5228-27 L100522BSS00 Solid 01/16/14 14:20 01/20/14 18:30 160-5228-28 L100523BSS00 Solid 01/16/14 14:35 01/20/14 18:30 160-5228-29 L100524BSS00 Solid 01/16/14 15:00 01/20/14 18:30 TestAmerica St. Louis Page 12 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-1 Client Sample ID: L100525BUB00 Matrix: Solid Date Collected: 01/19/14 12:50 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.11 (2+/-) 0.170 (2+/-) 1 02/13/14 10:01 01/23/14 09:31 pCi/g 0.103 RL MDC 0.126 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.404 0.448 0.427 1.30 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.0817 0.170 0.120 1.16 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.0793 0.160 0.0788 1.07 Lead 212 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.0717 0.167 0.0965 1.31 Lead 214 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.471 2.41 1.23 20.2 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 10:01 1 1.17 0.231 0.227 U 0.356 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.0817 1.00 0.170 0.120 1.16 Radium 226 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.103 0.170 0.126 1.11 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.956 0.742 0.731 1.20 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.228 0.207 0.201 0.512 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 10:01 1 0.118 0.0704 0.0704 U -0.0188 Americium 241 pCi/g 01/23/14 09:31 02/13/14 10:01 1 5.85 1.67 1.62 U 3.72 Protactinium 234m Lab Sample ID: 160-5228-2 Client Sample ID: L100526BUB00 Matrix: Solid Date Collected: 01/19/14 13:00 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.26 (2+/-) 0.198 (2+/-) 1 02/13/14 10:00 01/23/14 09:31 pCi/g 0.119 RL MDC 0.152 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.395 0.451 0.429 1.35 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.0858 0.169 0.117 1.17 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.0649 0.171 0.0836 1.15 Lead 212 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.0840 0.165 0.0993 1.27 Lead 214 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.253 2.48 1.37 20.2 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 10:00 1 1.41 0.263 0.256 U 0.520 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.0858 1.00 0.169 0.117 1.17 Radium 226 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.119 0.198 0.152 1.26 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.897 0.369 0.358 U 0.862 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.262 0.143 0.143 U 0.0895 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 10:00 1 0.120 0.0329 0.0329 U 0.000 Americium 241 pCi/g 01/23/14 09:31 02/13/14 10:00 1 6.34 3.67 3.67 U 1.44 Protactinium 234m Lab Sample ID: 160-5228-3 Client Sample ID: L100527BUB00 Matrix: Solid Date Collected: 01/19/14 13:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.30 (2+/-) 0.201 (2+/-) 1 02/13/14 10:15 01/23/14 09:31 pCi/g 0.0835 RL MDC 0.151 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.543 0.582 0.565 1.32 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.0593 0.178 0.125 1.22 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.0820 0.162 0.0889 1.04 Lead 212 TestAmerica St. Louis Page 13 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-3 Client Sample ID: L100527BUB00 Matrix: Solid Date Collected: 01/19/14 13:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Lead 214 1.32 (2+/-) 0.182 (2+/-) 1 02/13/14 10:15 01/23/14 09:31 pCi/g 0.103 RL MDC 0.118 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.596 2.49 1.54 19.1 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.771 0.474 0.472 U 0.404 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.0593 1.00 0.178 0.125 1.22 Radium 226 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.0835 0.201 0.151 1.30 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 10:15 1 1.24 0.450 0.437 U 1.01 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.230 0.146 0.145 U 0.208 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 10:15 1 0.124 0.0730 0.0730 U -0.000505 Americium 241 pCi/g 01/23/14 09:31 02/13/14 10:15 1 6.67 4.02 4.01 U 2.84 Protactinium 234m Lab Sample ID: 160-5228-4 Client Sample ID: L100528BUB00 Matrix: Solid Date Collected: 01/19/14 13:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.45 (2+/-) 0.208 (2+/-) 1 02/13/14 14:45 01/23/14 09:31 pCi/g 0.0829 RL MDC 0.154 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.522 0.405 0.390 1.12 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.0883 0.190 0.132 1.40 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.0911 0.154 0.0896 1.16 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.0965 0.190 0.112 1.59 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.524 2.20 1.30 18.4 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:45 1 1.43 0.875 0.872 U -0.786 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.0883 1.00 0.190 0.132 1.40 Radium 226 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.0829 0.208 0.154 1.45 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 14:45 1 1.16 0.403 0.391 U 0.985 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.292 0.177 0.177 U 0.156 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:45 1 0.109 0.0646 0.0646 U -0.00149 Americium 241 pCi/g 01/23/14 09:31 02/13/14 14:45 1 5.33 3.11 3.11 U 1.40 Protactinium 234m Lab Sample ID: 160-5228-5 Client Sample ID: L100501BES00 Matrix: Solid Date Collected: 01/16/14 08:55 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.18 (2+/-) 0.203 (2+/-) 1 02/13/14 14:46 01/23/14 09:31 pCi/g 0.0706 RL MDC 0.168 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.581 0.643 0.630 1.33 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.0845 0.179 0.134 1.21 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.0698 0.170 0.0939 1.31 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.0800 0.166 0.115 1.25 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.413 2.19 1.39 17.5 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:46 1 1.47 0.275 0.271 U 0.501 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.0845 1.00 0.179 0.134 1.21 Radium 226 TestAmerica St. Louis Page 14 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-5 Client Sample ID: L100501BES00 Matrix: Solid Date Collected: 01/16/14 08:55 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Thorium 232 1.18 (2+/-) 0.203 (2+/-) 1 02/13/14 14:46 01/23/14 09:31 pCi/g 0.0706 RL MDC 0.168 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:46 1 1.05 0.849 0.833 1.64 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.283 0.170 0.169 U 0.110 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:46 1 0.111 0.0661 0.0660 U -0.0190 Americium 241 pCi/g 01/23/14 09:31 02/13/14 14:46 1 7.63 3.69 3.65 U 5.35 Protactinium 234m Lab Sample ID: 160-5228-6 Client Sample ID: L100502BEQ00 Matrix: Solid Date Collected: 01/16/14 09:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.43 (2+/-) 0.246 (2+/-) 1 02/13/14 14:47 01/23/14 09:31 pCi/g 0.149 RL MDC 0.204 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.901 0.689 0.667 1.77 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.146 0.275 0.212 1.81 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.112 0.197 0.121 1.44 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.138 0.251 0.166 1.94 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.793 2.56 1.78 19.1 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:47 1 2.04 0.358 0.353 U 0.604 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.146 1.00 0.275 0.212 1.81 Radium 226 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.149 0.246 0.204 1.43 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 14:47 1 1.24 0.499 0.482 1.32 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.390 0.230 0.230 U 0.0448 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:47 1 0.157 0.0933 0.0933 U -0.0138 Americium 241 pCi/g 01/23/14 09:31 02/13/14 14:47 1 9.02 5.16 5.16 U 1.68 Protactinium 234m Lab Sample ID: 160-5228-7 Client Sample ID: L100502BES00 Matrix: Solid Date Collected: 01/16/14 09:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 2.11 (2+/-) 0.374 (2+/-) 1 02/13/14 14:43 01/23/14 09:31 pCi/g 0.148 RL MDC 0.306 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:43 1 1.59 1.04 1.03 U 1.27 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.264 0.363 0.314 1.76 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.235 0.298 0.220 1.55 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.258 0.365 0.306 1.92 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:43 1 1.02 3.17 2.49 19.3 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:43 1 3.58 0.655 0.646 U 0.967 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.264 1.00 0.363 0.314 1.76 Radium 226 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.148 0.374 0.306 2.11 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 14:43 1 3.29 2.49 2.47 U 2.86 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.726 0.441 0.441 U 0.282 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:43 1 0.273 0.158 0.158 U -0.0219 Americium 241 TestAmerica St. Louis Page 15 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-7 Client Sample ID: L100502BES00 Matrix: Solid Date Collected: 01/16/14 09:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Protactinium 234m -4.00 U (2+/-) 160 (2+/-) 1 02/13/14 14:43 01/23/14 09:31 pCi/g 21.1 RL MDC 160 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. Lab Sample ID: 160-5228-8 Client Sample ID: L100503BES00 Matrix: Solid Date Collected: 01/14/14 11:05 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.15 (2+/-) 0.178 (2+/-) 1 02/13/14 14:48 01/23/14 09:31 pCi/g 0.150 RL MDC 0.134 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.526 0.586 0.563 1.56 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.0715 0.173 0.119 1.20 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.0634 0.178 0.0818 1.23 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.0786 0.170 0.102 1.31 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.255 2.29 1.21 19.0 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:48 1 1.26 0.378 0.372 U 0.620 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.0715 1.00 0.173 0.119 1.20 Radium 226 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.150 0.178 0.134 1.15 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.952 0.734 0.724 1.18 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.212 0.163 0.162 U 0.162 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:48 1 0.0882 0.0645 0.0641 U 0.0716 Americium 241 pCi/g 01/23/14 09:31 02/13/14 14:48 1 5.50 3.17 3.16 U 1.67 Protactinium 234m Lab Sample ID: 160-5228-9 Client Sample ID: L100504BES00 Matrix: Solid Date Collected: 01/14/14 14:20 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.28 (2+/-) 0.228 (2+/-) 1 02/13/14 14:50 01/23/14 09:31 pCi/g 0.0983 RL MDC 0.186 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.520 0.667 0.633 2.04 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.0583 0.193 0.136 1.31 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.0858 0.185 0.0990 1.21 Lead 212 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.0999 0.186 0.138 1.21 Lead 214 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.409 2.54 1.57 19.6 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 14:50 1 1.55 0.261 0.257 U 0.410 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.0583 1.00 0.193 0.136 1.31 Radium 226 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.0983 0.228 0.186 1.28 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 14:50 1 1.35 0.392 0.381 U 0.858 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.269 0.148 0.147 U 0.153 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 14:50 1 0.131 0.0773 0.0773 U 0.000395 Americium 241 pCi/g 01/23/14 09:31 02/13/14 14:50 1 8.47 4.44 4.43 U 3.52 Protactinium 234m TestAmerica St. Louis Page 16 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-10 Client Sample ID: L100505BES00 Matrix: Solid Date Collected: 01/14/14 10:50 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.19 (2+/-) 0.182 (2+/-) 1 02/13/14 15:43 01/23/14 09:31 pCi/g 0.107 RL MDC 0.135 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.407 0.481 0.455 1.50 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.0754 0.161 0.107 1.16 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.0587 0.170 0.0760 1.18 Lead 212 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.0816 0.180 0.104 1.42 Lead 214 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.312 2.39 1.18 20.3 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.958 0.564 0.564 U 0.181 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.0754 1.00 0.161 0.107 1.16 Radium 226 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.107 0.182 0.135 1.19 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.815 0.332 0.316 0.966 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.208 0.151 0.148 0.312 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:43 1 0.120 0.0713 0.0713 U -0.00690 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:43 1 5.15 3.14 3.04 7.93 Protactinium 234m Lab Sample ID: 160-5228-11 Client Sample ID: L100506BES00 Matrix: Solid Date Collected: 01/14/14 14:00 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.20 (2+/-) 0.207 (2+/-) 1 02/13/14 15:44 01/23/14 09:31 pCi/g 0.118 RL MDC 0.172 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.396 0.448 0.429 1.35 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.0736 0.163 0.117 1.17 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.0801 0.139 0.0818 1.04 Lead 212 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.0838 0.161 0.112 1.19 Lead 214 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.417 2.40 1.30 21.0 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:44 1 1.37 0.832 0.829 U -0.645 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.0736 1.00 0.163 0.117 1.17 Radium 226 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.118 0.207 0.172 1.20 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.857 0.350 0.339 0.905 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.179 0.115 0.114 U 0.170 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:44 1 0.113 0.0675 0.0675 U 0.0149 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:44 1 5.54 3.31 3.31 U 2.11 Protactinium 234m Lab Sample ID: 160-5228-12 Client Sample ID: L100507BES00 Matrix: Solid Date Collected: 01/14/14 14:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.13 (2+/-) 0.224 (2+/-) 1 02/13/14 15:45 01/23/14 09:31 pCi/g 0.168 RL MDC 0.195 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.408 0.491 0.472 1.41 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.0872 0.183 0.138 1.23 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.0702 0.144 0.0860 1.07 Lead 212 TestAmerica St. Louis Page 17 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-12 Client Sample ID: L100507BES00 Matrix: Solid Date Collected: 01/14/14 14:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Lead 214 1.18 (2+/-) 0.155 (2+/-) 1 02/13/14 15:45 01/23/14 09:31 pCi/g 0.102 RL MDC 0.104 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.281 2.24 1.38 18.2 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:45 1 1.01 0.375 0.369 U 0.653 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.0872 1.00 0.183 0.138 1.23 Radium 226 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.168 0.224 0.195 1.13 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.992 0.379 0.369 U 0.891 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.276 0.0593 0.0591 U 0.0572 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:45 1 0.106 0.0626 0.0626 U 0.000655 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:45 1 7.14 3.09 3.08 U 0.656 Protactinium 234m Lab Sample ID: 160-5228-13 Client Sample ID: L100508BES00 Matrix: Solid Date Collected: 01/14/14 10:35 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.12 (2+/-) 0.185 (2+/-) 1 02/13/14 15:46 01/23/14 09:31 pCi/g 0.158 RL MDC 0.145 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.633 0.436 0.428 0.779 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.0970 0.191 0.147 1.18 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.0813 0.159 0.0862 1.03 Lead 212 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.0684 0.171 0.112 1.24 Lead 214 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.454 2.33 1.41 18.2 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:46 1 1.38 0.241 0.236 U 0.445 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.0970 1.00 0.191 0.147 1.18 Radium 226 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.158 0.185 0.145 1.12 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 15:46 1 1.07 0.363 0.353 U 0.792 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.279 0.164 0.164 U 0.00198 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:46 1 0.114 0.0679 0.0678 U 0.0198 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:46 1 6.36 1.72 1.72 U 0.133 Protactinium 234m Lab Sample ID: 160-5228-14 Client Sample ID: L100509BSS00 Matrix: Solid Date Collected: 01/17/14 14:30 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.15 (2+/-) 0.171 (2+/-) 1 02/13/14 15:47 01/23/14 09:31 pCi/g 0.0814 RL MDC 0.124 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.364 0.447 0.421 1.43 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.0715 0.151 0.106 1.03 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.0563 0.172 0.0752 1.19 Lead 212 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.0688 0.159 0.0946 1.24 Lead 214 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.433 2.38 1.23 19.9 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.914 0.294 0.288 U 0.566 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.0715 1.00 0.151 0.106 1.03 Radium 226 TestAmerica St. Louis Page 18 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-14 Client Sample ID: L100509BSS00 Matrix: Solid Date Collected: 01/17/14 14:30 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Thorium 232 1.15 (2+/-) 0.171 (2+/-) 1 02/13/14 15:47 01/23/14 09:31 pCi/g 0.0814 RL MDC 0.124 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.835 0.635 0.623 1.15 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.231 0.122 0.122 U 0.0897 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:47 1 0.105 0.0622 0.0622 U 0.00124 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:47 1 4.89 2.82 2.81 U 1.49 Protactinium 234m Lab Sample ID: 160-5228-15 Client Sample ID: L100510BSS00 Matrix: Solid Date Collected: 01/17/14 11:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.11 (2+/-) 0.245 (2+/-) 1 02/13/14 15:48 01/23/14 09:31 pCi/g 0.141 RL MDC 0.217 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.768 0.518 0.510 0.891 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.0724 0.187 0.135 1.24 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.0810 0.167 0.0897 1.09 Lead 212 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.100 0.176 0.117 1.27 Lead 214 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.360 2.39 1.44 18.7 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 15:48 1 1.48 0.261 0.257 U 0.395 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.0724 1.00 0.187 0.135 1.24 Radium 226 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.141 0.245 0.217 1.11 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 15:48 1 1.04 0.814 0.798 1.53 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.284 0.168 0.168 U 0.0328 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 15:48 1 0.110 0.0649 0.0649 U 0.00328 Americium 241 pCi/g 01/23/14 09:31 02/13/14 15:48 1 8.01 0.781 0.781 U -0.116 Protactinium 234m Lab Sample ID: 160-5228-16 Client Sample ID: L100511BSS00 Matrix: Solid Date Collected: 01/17/14 10:45 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.17 (2+/-) 0.161 (2+/-) 1 02/13/14 16:26 01/23/14 09:31 pCi/g 0.0969 RL MDC 0.108 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.341 0.479 0.438 1.88 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.0608 0.170 0.103 1.30 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.0622 0.167 0.0721 1.16 Lead 212 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.0740 0.166 0.0843 1.38 Lead 214 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.314 2.29 1.09 19.7 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 16:26 1 1.11 0.682 0.679 U -0.606 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.0608 1.00 0.170 0.103 1.30 Radium 226 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.0969 0.161 0.108 1.17 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.943 0.828 0.804 1.90 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.163 0.101 0.0996 U 0.155 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 16:26 1 0.108 0.0645 0.0645 U -0.00558 Americium 241 TestAmerica St. Louis Page 19 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-16 Client Sample ID: L100511BSS00 Matrix: Solid Date Collected: 01/17/14 10:45 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Protactinium 234m 4.96 U (2+/-) 2.13 (2+/-) 1 02/13/14 16:26 01/23/14 09:31 pCi/g 6.38 RL MDC 2.07 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. Lab Sample ID: 160-5228-17 Client Sample ID: L100512BSS00 Matrix: Solid Date Collected: 01/17/14 10:50 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.20 (2+/-) 0.202 (2+/-) 1 02/13/14 16:27 01/23/14 09:31 pCi/g 0.0907 RL MDC 0.160 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.423 0.509 0.484 1.54 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.0684 0.171 0.110 1.26 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.0786 0.162 0.0786 1.10 Lead 212 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.0769 0.180 0.108 1.38 Lead 214 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.357 2.47 1.19 21.1 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 16:27 1 1.19 0.726 0.723 U -0.639 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.0684 1.00 0.171 0.110 1.26 Radium 226 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.0907 0.202 0.160 1.20 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.897 0.737 0.715 1.69 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.187 0.117 0.116 U 0.152 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 16:27 1 0.112 0.0672 0.0671 U -0.0180 Americium 241 pCi/g 01/23/14 09:31 02/13/14 16:27 1 4.80 2.97 2.96 U 2.81 Protactinium 234m Lab Sample ID: 160-5228-18 Client Sample ID: L100513BSS00 Matrix: Solid Date Collected: 01/17/14 14:20 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.31 (2+/-) 0.191 (2+/-) 1 02/13/14 16:28 01/23/14 09:31 pCi/g 0.114 RL MDC 0.137 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.610 0.422 0.414 0.790 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0735 0.186 0.125 1.33 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0638 0.176 0.0839 1.20 Lead 212 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.111 0.201 0.143 1.35 Lead 214 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.246 2.50 1.36 20.4 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.931 0.398 0.387 U 0.860 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0735 1.00 0.186 0.125 1.33 Radium 226 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.114 0.191 0.137 1.31 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.926 0.357 0.343 0.958 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.264 0.145 0.145 U 0.0902 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.107 0.0639 0.0638 U -0.0214 Americium 241 pCi/g 01/23/14 09:31 02/13/14 16:28 1 6.01 3.86 3.83 U 4.51 Protactinium 234m TestAmerica St. Louis Page 20 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-19 Client Sample ID: L100514BSS00 Matrix: Solid Date Collected: 01/17/14 13:50 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.04 (2+/-) 0.203 (2+/-) 1 02/13/14 16:28 01/23/14 09:31 pCi/g 0.169 RL MDC 0.173 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.436 0.461 0.448 1.05 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0821 0.172 0.127 1.12 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0854 0.162 0.0899 1.05 Lead 212 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0923 0.179 0.129 1.19 Lead 214 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.472 2.42 1.47 18.8 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 16:28 1 1.41 0.296 0.293 U 0.374 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.0821 1.00 0.172 0.127 1.12 Radium 226 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.169 0.203 0.173 1.04 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.943 0.705 0.690 1.38 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.306 0.176 0.175 U 0.144 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 16:28 1 0.123 0.0735 0.0735 U 0.0227 Americium 241 pCi/g 01/23/14 09:31 02/13/14 16:28 1 9.75 2.78 2.78 U 0.592 Protactinium 234m Lab Sample ID: 160-5228-20 Client Sample ID: L100515BSS00 Matrix: Solid Date Collected: 01/17/14 14:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.21 (2+/-) 0.190 (2+/-) 1 02/13/14 16:29 01/23/14 09:31 pCi/g 0.108 RL MDC 0.144 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.343 0.394 0.371 1.28 Bismuth 212 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.0760 0.166 0.117 1.12 Bismuth 214 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.0578 0.169 0.0758 1.16 Lead 212 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.0708 0.169 0.104 1.29 Lead 214 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.310 2.29 1.18 19.2 Potassium 40 pCi/g 01/23/14 09:31 02/13/14 16:29 1 1.22 0.743 0.740 U -0.554 Protactinium 231 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.0760 1.00 0.166 0.117 1.12 Radium 226 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.108 0.190 0.144 1.21 Thorium 232 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.907 0.710 0.696 1.35 Thorium 234 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.165 0.121 0.119 0.182 Uranium 235 pCi/g 01/23/14 09:31 02/13/14 16:29 1 0.110 0.0655 0.0655 U -0.0207 Americium 241 pCi/g 01/23/14 09:31 02/13/14 16:29 1 5.52 2.67 2.67 U 0.324 Protactinium 234m Lab Sample ID: 160-5228-21 Client Sample ID: L100516BSS00 Matrix: Solid Date Collected: 01/17/14 11:00 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.13 (2+/-) 0.178 (2+/-) 1 02/13/14 19:10 01/23/14 11:51 pCi/g 0.133 RL MDC 0.140 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.377 0.466 0.444 1.45 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.104 0.179 0.140 1.15 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.0938 0.151 0.0909 1.12 Lead 212 TestAmerica St. Louis Page 21 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-21 Client Sample ID: L100516BSS00 Matrix: Solid Date Collected: 01/17/14 11:00 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Lead 214 1.41 (2+/-) 0.178 (2+/-) 1 02/13/14 19:10 01/23/14 11:51 pCi/g 0.0791 RL MDC 0.114 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.478 2.39 1.36 20.4 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 19:10 1 1.38 0.278 0.275 U 0.416 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.104 1.00 0.179 0.140 1.15 Radium 226 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.133 0.178 0.140 1.13 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.957 0.776 0.765 1.30 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.260 0.168 0.168 U 0.161 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.113 0.0667 0.0667 U -0.00285 Americium 241 pCi/g 01/23/14 11:51 02/13/14 19:10 1 6.10 2.96 2.96 U 0.951 Protactinium 234m Lab Sample ID: 160-5228-22 Client Sample ID: L100517BSS00 Matrix: Solid Date Collected: 01/16/14 15:35 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.25 (2+/-) 0.213 (2+/-) 1 02/13/14 19:11 01/23/14 11:51 pCi/g 0.134 RL MDC 0.170 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.479 0.597 0.571 1.67 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.0732 0.188 0.126 1.35 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.0697 0.186 0.0868 1.27 Lead 212 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.0950 0.182 0.114 1.37 Lead 214 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.240 2.32 1.29 18.9 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 19:11 1 1.32 0.801 0.798 U -0.643 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.0732 1.00 0.188 0.126 1.35 Radium 226 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.134 0.213 0.170 1.25 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.992 0.791 0.771 1.69 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.249 0.149 0.149 U 0.0371 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 19:11 1 0.110 0.0649 0.0649 U 0.00137 Americium 241 pCi/g 01/23/14 11:51 02/13/14 19:11 1 6.13 2.92 2.86 U 5.66 Protactinium 234m Lab Sample ID: 160-5228-23 Client Sample ID: L100518BSS00 Matrix: Solid Date Collected: 01/16/14 15:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.37 (2+/-) 0.177 (2+/-) 1 02/18/14 12:32 01/23/14 11:51 pCi/g 0.0807 RL MDC 0.117 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.279 0.335 0.302 1.48 Bismuth 212 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.0480 0.176 0.0778 1.62 Bismuth 214 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.0363 0.154 0.0467 1.37 Lead 212 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.0460 0.178 0.0616 1.72 Lead 214 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.243 1.96 0.692 19.1 Potassium 40 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.732 0.455 0.451 U -0.629 Protactinium 231 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.0480 1.00 0.176 0.0778 1.62 Radium 226 TestAmerica St. Louis Page 22 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-23 Client Sample ID: L100518BSS00 Matrix: Solid Date Collected: 01/16/14 15:10 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Thorium 232 1.37 (2+/-) 0.177 (2+/-) 1 02/18/14 12:32 01/23/14 11:51 pCi/g 0.0807 RL MDC 0.117 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.514 0.423 0.398 1.45 Thorium 234 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.115 0.0735 0.0709 0.200 Uranium 235 pCi/g 01/23/14 11:51 02/18/14 12:32 1 0.0610 0.0367 0.0367 U -0.0105 Americium 241 pCi/g 01/23/14 11:51 02/18/14 12:32 1 3.54 1.72 1.57 7.26 Protactinium 234m Lab Sample ID: 160-5228-24 Client Sample ID: L100519BSS00 Matrix: Solid Date Collected: 01/17/14 14:55 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.37 (2+/-) 0.197 (2+/-) 1 02/13/14 19:10 01/23/14 11:51 pCi/g 0.147 RL MDC 0.146 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.488 0.511 0.494 1.35 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.0804 0.239 0.147 1.94 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.0701 0.190 0.0937 1.54 Lead 212 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.101 0.231 0.131 1.97 Lead 214 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.380 2.41 1.34 20.8 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 19:10 1 1.43 0.267 0.263 U 0.455 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.0804 1.00 0.239 0.147 1.94 Radium 226 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.147 0.197 0.146 1.37 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.871 0.641 0.625 1.45 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.274 0.178 0.178 U 0.0992 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 19:10 1 0.119 0.0708 0.0708 U -0.00350 Americium 241 pCi/g 01/23/14 11:51 02/13/14 19:10 1 6.56 3.90 3.89 U 2.94 Protactinium 234m Lab Sample ID: 160-5228-25 Client Sample ID: L100520BSS00 Matrix: Solid Date Collected: 01/17/14 14:45 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.41 (2+/-) 0.244 (2+/-) 1 02/13/14 20:11 01/23/14 11:51 pCi/g 0.0910 RL MDC 0.197 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.521 0.623 0.587 2.01 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.0829 0.246 0.167 1.75 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.0910 0.217 0.107 1.46 Lead 212 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.112 0.221 0.131 1.71 Lead 214 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.567 2.35 1.53 17.5 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 20:11 1 1.70 0.352 0.345 U 0.629 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.0829 1.00 0.246 0.167 1.75 Radium 226 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.0910 0.244 0.197 1.41 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 20:11 1 1.37 0.385 0.380 U 0.604 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.311 0.190 0.189 U 0.137 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 20:11 1 0.0958 0.0570 0.0569 U 0.0213 Americium 241 TestAmerica St. Louis Page 23 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-25 Client Sample ID: L100520BSS00 Matrix: Solid Date Collected: 01/17/14 14:45 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Analyte Protactinium 234m -0.267 U (2+/-) 3.71 (2+/-) 1 02/13/14 20:11 01/23/14 11:51 pCi/g 9.51 RL MDC 3.71 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. Lab Sample ID: 160-5228-26 Client Sample ID: L100521BSS00 Matrix: Solid Date Collected: 01/16/14 14:15 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.32 (2+/-) 0.228 (2+/-) 1 02/13/14 20:06 01/23/14 11:51 pCi/g 0.151 RL MDC 0.189 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.624 0.706 0.683 1.84 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.112 0.243 0.167 1.81 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.105 0.173 0.103 1.30 Lead 212 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.112 0.231 0.145 1.85 Lead 214 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.592 2.35 1.43 19.4 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 20:06 1 1.54 0.332 0.328 U 0.525 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.112 1.00 0.243 0.167 1.81 Radium 226 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.151 0.228 0.189 1.32 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 20:06 1 1.09 0.390 0.386 U 0.545 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.324 0.188 0.187 U 0.142 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 20:06 1 0.132 0.0793 0.0793 U -0.0289 Americium 241 pCi/g 01/23/14 11:51 02/13/14 20:06 1 7.77 4.49 4.49 U -1.19 Protactinium 234m Lab Sample ID: 160-5228-27 Client Sample ID: L100522BSS00 Matrix: Solid Date Collected: 01/16/14 14:20 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.63 (2+/-) 0.286 (2+/-) 1 02/13/14 20:07 01/23/14 11:51 pCi/g 0.124 RL MDC 0.240 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.470 0.528 0.510 1.41 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.0802 0.206 0.147 1.49 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.0776 0.167 0.0968 1.26 Lead 212 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.0922 0.199 0.127 1.58 Lead 214 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.479 2.47 1.55 19.9 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 20:07 1 1.39 0.412 0.405 U 0.730 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.0802 1.00 0.206 0.147 1.49 Radium 226 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.124 0.286 0.240 1.63 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.960 0.724 0.709 1.51 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.301 0.202 0.201 U 0.160 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 20:07 1 0.111 0.0655 0.0655 U -0.0142 Americium 241 pCi/g 01/23/14 11:51 02/13/14 20:07 1 6.74 4.10 4.09 U 3.20 Protactinium 234m TestAmerica St. Louis Page 24 of 29 1 2 3 4 5 6 7 8 9 10 11

Client Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Lab Sample ID: 160-5228-28 Client Sample ID: L100523BSS00 Matrix: Solid Date Collected: 01/16/14 14:35 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.22 (2+/-) 0.235 (2+/-) 1 02/13/14 20:08 01/23/14 11:51 pCi/g 0.195 RL MDC 0.203 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.439 0.713 0.660 2.76 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.0936 0.210 0.158 1.43 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.0989 0.177 0.108 1.31 Lead 212 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.104 0.197 0.133 1.50 Lead 214 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.382 2.40 1.55 18.9 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 20:08 1 1.75 0.310 0.307 U 0.446 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.0936 1.00 0.210 0.158 1.43 Radium 226 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.195 0.235 0.203 1.22 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 20:08 1 1.11 0.402 0.389 U 1.03 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.268 0.164 0.164 U 0.117 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 20:08 1 0.141 0.0833 0.0833 U 0.000189 Americium 241 pCi/g 01/23/14 11:51 02/13/14 20:08 1 7.84 4.39 4.39 U 0.809 Protactinium 234m Lab Sample ID: 160-5228-29 Client Sample ID: L100524BSS00 Matrix: Solid Date Collected: 01/16/14 15:00 Date Received: 01/20/14 18:30 Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Analyte Actinium 228 1.27 (2+/-) 0.210 (2+/-) 1 02/13/14 20:09 01/23/14 11:51 pCi/g 0.167 RL MDC 0.171 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert. Uncert. pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.331 0.454 0.419 1.79 Bismuth 212 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.0640 0.224 0.135 1.84 Bismuth 214 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.0765 0.180 0.0918 1.44 Lead 212 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.0911 0.237 0.127 2.06 Lead 214 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.265 2.51 1.33 22.2 Potassium 40 pCi/g 01/23/14 11:51 02/13/14 20:09 1 1.35 0.263 0.259 U 0.420 Protactinium 231 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.0640 1.00 0.224 0.135 1.84 Radium 226 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.167 0.210 0.171 1.27 Thorium 232 pCi/g 01/23/14 11:51 02/13/14 20:09 1 1.03 0.401 0.391 U 0.890 Thorium 234 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.278 0.166 0.165 U 0.151 Uranium 235 pCi/g 01/23/14 11:51 02/13/14 20:09 1 0.113 0.0669 0.0669 U -0.00122 Americium 241 pCi/g 01/23/14 11:51 02/13/14 20:09 1 8.42 28.3 28.3 U -0.707 Protactinium 234m TestAmerica St. Louis Page 25 of 29 1 2 3 4 5 6 7 8 9 10 11

QC Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) Client Sample ID: Method Blank Lab Sample ID: MB 160-100838/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 105155 Prep Batch: 100838 Actinium 228 Analyte U 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0935 MDC RL 0.0503 0.0503 (2+/-) (2+/-) MB -0.01195 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert. Count Uncert. Total 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.222 0.106 0.106 U -0.0007132 Bismuth 212 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0413 0.0197 0.0197 U 0.003746 Bismuth 214 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0259 0.0137 0.0137 U 0.006725 Lead 212 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0268 0.0174 0.0173 U 0.01265 Lead 214 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.311 4.76 4.76 U -0.1189 Potassium 40 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.414 0.217 0.217 U -0.003736 Protactinium 231 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0413 1.00 0.0197 0.0197 U 0.003746 Radium 226 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0935 0.0503 0.0503 U -0.01195 Thorium 232 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.256 0.0939 0.0934 U 0.09929 Thorium 234 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0696 0.0358 0.0358 U 0.01131 Uranium 235 1 02/13/14 09:59 01/23/14 09:31 pCi/g 0.0232 0.0132 0.0132 U 0.005261 Americium 241 1 02/13/14 09:59 01/23/14 09:31 pCi/g 2.09 0.0291 0.0290 U -0.01358 Protactinium 234m Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-100838/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 105158 Prep Batch: 100838 Americium 241 Analyte 116 87 99 99.98 101 10.4 0.518 RL MDC (2+/-) LCS LCS pCi/g Unit Result Qual %Rec Added Spike Limits %Rec. Uncert. Total Cesium 137 35.8 34.79 3.64 0.174 pCi/g 97 87 - 120 Cobalt 60 42.0 40.08 4.04 0.0967 pCi/g 96 87 - 115 Client Sample ID: L100525BUB00 Lab Sample ID: 160-5228-1 DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 105158 Prep Batch: 100838 Actinium 228 Analyte 1 0.35 1.236 1.11 0.193 0.119 RL MDC (2+/-) DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert. Total RER RER Bismuth 212 1.30 1.269 0.475 0.420 pCi/g 0.03 1 Bismuth 214 1.16 1.221 0.175 0.0828 pCi/g 0.17 1 Lead 212 1.07 1.205 0.174 0.0587 pCi/g 0.39 1 Lead 214 1.31 1.377 0.177 0.0889 pCi/g 0.19 1 Potassium 40 20.2 22.19 2.60 0.417 pCi/g 0.39 1 Protactinium 231 0.356 U 0.2240 U 0.557 0.941 pCi/g 0.17 1 Radium 226 1.16 1.221 0.175 1.00 0.0828 pCi/g 0.17 1 Thorium 232 1.11 1.236 0.193 0.119 pCi/g 0.35 1 Thorium 234 1.20 2.100 0.820 0.960 pCi/g 0.58 1 Uranium 235 0.512 0.6002 0.216 0.223 pCi/g 0.21 1 Americium 241 -0.0188 U 0.03552 U 0.0661 0.110 pCi/g 0.40 1 Protactinium 234m 3.72 U 6.402 3.50 5.47 pCi/g 0.52 1 TestAmerica St. Louis Page 26 of 29 1 2 3 4 5 6 7 8 9 10 11

QC Sample Results TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Method: GA-01-R - Radium-226 & Other Gamma Emitters (GS) (Continued) Client Sample ID: Method Blank Lab Sample ID: MB 160-100878/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 106111 Prep Batch: 100878 Actinium 228 Analyte U 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0741 MDC RL 0.0393 0.0393 (2+/-) (2+/-) MB -0.006739 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert. Count Uncert. Total 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.147 0.0672 0.0672 U 0.001231 Bismuth 212 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0292 0.00214 0.00213 U 0.0009563 Bismuth 214 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0278 0.0282 0.0282 U -0.003682 Lead 212 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0352 0.0178 0.0178 U 0.002858 Lead 214 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.198 2.23 2.23 U -0.05587 Potassium 40 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.400 0.216 0.216 U -0.01080 Protactinium 231 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0292 1.00 0.00214 0.00213 U 0.0009563 Radium 226 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0741 0.0393 0.0393 U -0.006739 Thorium 232 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.217 0.0792 0.0792 U 0.03976 Thorium 234 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0715 0.00222 0.00222 U -0.0007164 Uranium 235 1 02/19/14 20:42 01/23/14 11:51 pCi/g 0.0229 0.0143 0.0143 U 0.01364 Americium 241 1 02/19/14 20:42 01/23/14 11:51 pCi/g 1.21 0.329 0.329 U 0.0000 Protactinium 234m Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-100878/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 105821 Prep Batch: 100878 Americium 241 Analyte 116 87 93 93.96 101 9.32 0.277 RL MDC (2+/-) LCS LCS pCi/g Unit Result Qual %Rec Added Spike Limits %Rec. Uncert. Total Cesium 137 35.8 35.25 3.44 0.110 pCi/g 99 87 - 120 Cobalt 60 41.9 41.01 3.93 0.0821 pCi/g 98 87 - 115 Client Sample ID: L100516BSS00 Lab Sample ID: 160-5228-21 DU Matrix: Solid Prep Type: Total/NA Analysis Batch: 105158 Prep Batch: 100878 Actinium 228 Analyte 1 0.56 1.357 1.13 0.218 0.169 RL MDC (2+/-) DU DU pCi/g Unit Result Qual Limit Result Sample Sample Qual Uncert. Total RER RER Bismuth 212 1.45 1.046 0.446 0.609 pCi/g 0.44 1 Bismuth 214 1.15 1.191 0.181 0.100 pCi/g 0.10 1 Lead 212 1.12 1.351 0.224 0.0717 pCi/g 0.62 1 Lead 214 1.41 1.551 0.206 0.0918 pCi/g 0.37 1 Potassium 40 20.4 20.07 2.35 0.404 pCi/g 0.08 1 Protactinium 231 0.416 U -0.7475 U 0.859 1.40 pCi/g 1.02 1 Radium 226 1.15 1.191 0.181 1.00 0.100 pCi/g 0.10 1 Thorium 232 1.13 1.357 0.218 0.169 pCi/g 0.56 1 Thorium 234 1.30 1.083 U 0.420 1.17 pCi/g 0.18 1 Uranium 235 0.161 U 0.1387 U 0.177 0.290 pCi/g 0.07 1 Americium 241 -0.00285 U 0.000026 84 U 0.0621 0.105 pCi/g 0.02 1 Protactinium 234m 0.951 U 5.758 U 3.44 6.49 pCi/g 0.75 1 TestAmerica St. Louis Page 27 of 29 1 2 3 4 5 6 7 8 9 10 11

QC Association Summary TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Rad Leach Batch: 100327 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Dry and Grind 160-5228-1 L100525BUB00 Total/NA Solid Dry and Grind 160-5228-1 DU L100525BUB00 Total/NA Solid Dry and Grind 160-5228-2 L100526BUB00 Total/NA Solid Dry and Grind 160-5228-3 L100527BUB00 Total/NA Solid Dry and Grind 160-5228-4 L100528BUB00 Total/NA Solid Dry and Grind 160-5228-5 L100501BES00 Total/NA Solid Dry and Grind 160-5228-6 L100502BEQ00 Total/NA Solid Dry and Grind 160-5228-7 L100502BES00 Total/NA Solid Dry and Grind 160-5228-8 L100503BES00 Total/NA Solid Dry and Grind 160-5228-9 L100504BES00 Total/NA Solid Dry and Grind 160-5228-10 L100505BES00 Total/NA Solid Dry and Grind 160-5228-11 L100506BES00 Total/NA Solid Dry and Grind 160-5228-12 L100507BES00 Total/NA Solid Dry and Grind 160-5228-13 L100508BES00 Total/NA Solid Dry and Grind 160-5228-14 L100509BSS00 Total/NA Solid Dry and Grind 160-5228-15 L100510BSS00 Total/NA Solid Dry and Grind 160-5228-16 L100511BSS00 Total/NA Solid Dry and Grind 160-5228-17 L100512BSS00 Total/NA Solid Dry and Grind 160-5228-18 L100513BSS00 Total/NA Solid Dry and Grind 160-5228-19 L100514BSS00 Total/NA Solid Dry and Grind 160-5228-20 L100515BSS00 Total/NA Solid Dry and Grind 160-5228-21 L100516BSS00 Total/NA Solid Dry and Grind 160-5228-21 DU L100516BSS00 Total/NA Solid Dry and Grind 160-5228-22 L100517BSS00 Total/NA Solid Dry and Grind 160-5228-23 L100518BSS00 Total/NA Solid Dry and Grind 160-5228-24 L100519BSS00 Total/NA Solid Dry and Grind 160-5228-25 L100520BSS00 Total/NA Solid Dry and Grind 160-5228-26 L100521BSS00 Total/NA Solid Dry and Grind 160-5228-27 L100522BSS00 Total/NA Solid Dry and Grind 160-5228-28 L100523BSS00 Total/NA Solid Dry and Grind 160-5228-29 L100524BSS00 Total/NA Prep Batch: 100838 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 100327 160-5228-1 L100525BUB00 Total/NA Solid Fill_Geo-21 100327 160-5228-1 DU L100525BUB00 Total/NA Solid Fill_Geo-21 100327 160-5228-2 L100526BUB00 Total/NA Solid Fill_Geo-21 100327 160-5228-3 L100527BUB00 Total/NA Solid Fill_Geo-21 100327 160-5228-4 L100528BUB00 Total/NA Solid Fill_Geo-21 100327 160-5228-5 L100501BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-6 L100502BEQ00 Total/NA Solid Fill_Geo-21 100327 160-5228-7 L100502BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-8 L100503BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-9 L100504BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-10 L100505BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-11 L100506BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-12 L100507BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-13 L100508BES00 Total/NA Solid Fill_Geo-21 100327 160-5228-14 L100509BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-15 L100510BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-16 L100511BSS00 Total/NA TestAmerica St. Louis Page 28 of 29 1 2 3 4 5 6 7 8 9 10 11

QC Association Summary TestAmerica Job ID: 160-5228-2 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (21 DAY TAT) Rad (Continued) Prep Batch: 100838 (Continued) Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 100327 160-5228-17 L100512BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-18 L100513BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-19 L100514BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-20 L100515BSS00 Total/NA Solid Fill_Geo-21 LCS 160-100838/2-A Lab Control Sample Total/NA Solid Fill_Geo-21 MB 160-100838/1-A Method Blank Total/NA Prep Batch: 100878 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Fill_Geo-21 100327 160-5228-21 L100516BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-21 DU L100516BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-22 L100517BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-23 L100518BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-24 L100519BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-25 L100520BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-26 L100521BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-27 L100522BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-28 L100523BSS00 Total/NA Solid Fill_Geo-21 100327 160-5228-29 L100524BSS00 Total/NA Solid Fill_Geo-21 LCS 160-100878/2-A Lab Control Sample Total/NA Solid Fill_Geo-21 MB 160-100878/1-A Method Blank Total/NA TestAmerica St. Louis Page 29 of 29 1 2 3 4 5 6 7 8 9 10 11}}