Final Status Survey Final Report Volume 3, Chapter 6, Survey Area Release Record for Land Survey Area 10, Analytical Report, 160-4779-1
ML18010A308
Person / Time
Site: 07000036
(SNM-0033)
Issue date: 12/16/2013
From:
TestAmerica Labs - St. Louis, Westinghouse
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18010A247 List: ... further results
References
HEM-17-72 160-4779-1
Download: ML18010A308 (22)


Text

ANALYTICAL REPORT TestAmerica Laboratories, Inc.

TestAmerica St. Louis 13715 Rider Trail North Earth City, MO 63045 Tel: (314)298-8566 TestAmerica Job ID: 160-4779-1 Client Project/Site: RFP-CBA-022 (7 DAY TAT)

For:

Westinghouse Electric Company LLC 3300 State Road P Festus, Missouri 63028 Attn: Martin Swanson Authorized for release by:

12/16/2013 2:42:56 PM Ivan Vania, Project Manager II (314)298-8566 ivan.vania@testamericainc.com This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature.

Results relate only to the items tested and the sample(s) as received by the laboratory.

1 2

3 4

5 6

7 8

9 10 11 12

Table of Contents Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

TestAmerica Job ID: 160-4779-1 Page 2 of 22 Cover Page..............................................

1 Table of Contents.........................................

2 Case Narrative...........................................

3 Chain of Custody..........................................

5 Receipt Checklists.........................................

7 Definitions/Glossary.......................................

8 Method Summary.........................................

9 Sample Summary.........................................

10 Client Sample Results......................................

11 QC Sample Results........................................

16 QC Association Summary...................................

19 Tracer Carrier Summary....................................

22 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4779-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4779-1 Laboratory: TestAmerica St. Louis Narrative CASE NARRATIVE Client: Westinghouse Electric Company LLC Project: RFP-CBA-022 (7 DAY TAT)

Report Number: 160-4779-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In some cases, due to interference or analytes present at high concentrations, samples were diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required.

TestAmerica St. Louis attests to the validity of the laboratory data generated by TestAmerica facilities reported herein. All analyses performed by TestAmerica facilities were done using established laboratory SOPs that incorporate QA/QC procedures described in the application methods. TestAmericas operations groups have reviewed the data for compliance with the laboratory QA/QC plan, and data have been found to be compliant with laboratory protocols unless otherwise noted below.

The test results in this report meet all NELAP requirements for parameters for which accreditation is required or available. Any exceptions to NELAP requirements are noted in this report. Pursuant to NELAP, this report may not be reproduced, except in full, without the written approval of the laboratory.

Calculations are performed before rounding to avoid round-off errors in calculated results.

All holding times were met and proper preservation noted for the methods performed on these samples, unless otherwise detailed in the individual sections below.

All solid sample results for Chemistry analyses are reported on an "as received" basis unless otherwise indicated by the presence of a %

solids value in the method header. All soil/sediment sample results for radiochemistry analyses are based upon sample as dried and disaggregated with the exception of tritium, carbon-14, and iodine-129 by gamma spectroscopy unless requested as wet weight by the client.

This laboratory report is confidential and is intended for the sole use of TestAmerica and its client.

RECEIPT The samples were received on 12/05/2013; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 18.0 C.

TECHNETIUM-99 (ICPMS)

Samples L101001BRS00 (160-4779-1), L101002BES00 (160-4779-2), L101003BRS00 (160-4779-3), L101005BRS00 (160-4779-4),

L101006BES00 (160-4779-5), L101007BRS00 (160-4779-6), L101008BES00 (160-4779-7), L101009BSS00 (160-4779-8),

L101010BRS00 (160-4779-9), L101011BSQ00 (160-4779-10), L101011BSS00 (160-4779-11), L101012BRS00 (160-4779-12),

L101013BSS00 (160-4779-13), L101014BRS00 (160-4779-14) and L101015BES00 (160-4779-15) were analyzed for Technetium-99 (ICPMS) in accordance with EPA SW-846 Method 6020A. The samples were prepared on 12/10/2013 and 12/13/2013 and analyzed on 12/11/2013 and 12/15/2013.

No difficulties were encountered during the Tc-99 analysis. All quality control parameters were within the acceptance limits.

PERCENT SOLIDS TestAmerica St. Louis Page 3 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Case Narrative Client: Westinghouse Electric Company LLC TestAmerica Job ID: 160-4779-1 Project/Site: RFP-CBA-022 (7 DAY TAT)

Job ID: 160-4779-1 (Continued)

Laboratory: TestAmerica St. Louis (Continued)

Samples L101001BRS00 (160-4779-1), L101002BES00 (160-4779-2), L101003BRS00 (160-4779-3), L101005BRS00 (160-4779-4),

L101006BES00 (160-4779-5), L101007BRS00 (160-4779-6), L101008BES00 (160-4779-7), L101009BSS00 (160-4779-8),

L101010BRS00 (160-4779-9), L101011BSQ00 (160-4779-10), L101011BSS00 (160-4779-11), L101012BRS00 (160-4779-12),

L101013BSS00 (160-4779-13), L101014BRS00 (160-4779-14) and L101015BES00 (160-4779-15) were analyzed for percent solids in accordance with EPA Method 160.3 MOD. The samples were analyzed on 12/07/2013.

No difficulties were encountered during the % solids analysis. All quality control parameters were within the acceptance limits.

TestAmerica St. Louis Page 4 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Page 5 of 22 1

2 3

4 5

6 7

8 9

10 11 12 Procedure HDP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I

Page 1 ofl Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each time the container is transferred to another organization, a person from each organization should sign the Coe. The Laboratory/End User must verify tha1 the sample is correctly identified before the sample is released for use or analysis and send the completed Coe to EDP.

Chain of Cutod:v ID No.

F-120513-01 Pa2e 1/2 Requested Analysis Laboratorv Name:

Project Name:

TA-MO

'!:)

N Westinghouse Electric Company N

r**

~...*.

I Contact Person:

Laboratory Address:

Gerald Rood

.* :- ]

13715 Rider Trail North

~

i Phone Number:

  • e Phone No.

314-810-3382 8 314-298-8566 s

Sampler Name

-a Laboratory Contact Person:

"Cl

§ Scott Jenkins

§:

s Joe Walker

.a

-- ~

Phone No-ci o.

§ 0

. OJ..

OJ 708-870-8453

~

  • f:i;
i b5' I 0

00.**

Turn Around Time Q

.o:i.*

0 d

l * -~ 8:: s Rush (7 days)

0.

s E

  • . b*

Sample ID Date Time Matrix 0

0 Remarks u

d

~ b 0

I LIO l 00 lBRSOO 12/4/2013 10:15 s C

X X

1 LSA-10-10 Sys. Samples LIO 1002BESOO 12/4/2013 10:20 s

C..

X X

1 LSA-10-10 Sys. Samples LIOI003BRSOO 12/4/2013 10:45 s

C X

X 1 LSA-10-10 Sys. Samples LI01005BRSOO 12/4/2013 11:00 s C

X X

I LSA-10-10 Sys. Samples L 101006BESOO 12/4/2013 11 :05 s

C X

X 1 LSA-10-10 Sys. Samples LIO I 007BRSOO 12/4/2013 13:55 s

C X

X 1 LSA-10-10 Sys. Samples LI01008BESOO 12/4/2013 14:00 s C

X X

1 LSA-10-10 Sys. Samples LIO 1009BSSOO 12/4/2013 14:10 s C

X X

1 LSA-10-10 Sys. Samples Ll01010BRSOO 12/4/2013 14:25 s

C X

X 1 LSA-10-10 Sys. Samples LI01011BSQOO 12/4/2013 14:45 s

C X

X 1 LSA-10-10 QC Sample Ll01011BSSOO 12/4/2013 14:45 s

C X

X 1 LSA-10-10 Sys. Samples LI01012BRSOO 12/4/2013 14:55 s

C X

X I LSA-10-10 Sys. Samples Relinquished b?

r-Date/Time Ref~by: /?£}_

Date/Time Total Cooler Temperature:

r-2:1 A.,Q

{1/s ff:;e; l'i 4 nP.DTP.f>S: ('_

Company Namet..c) Et _

,2.-s-0/ Company Name:,

Cooler ID: Shipper and Number:

1<<5 n~foad.5 1?0-<i.O?

Received by:

Daterfime

~~d~y2/,.

DatelTime Comments: Please analyze the samples for Tc-99 on a 7 day 1,:'? i,;C; TAT. Please analyze the samples for gamma spec after a 21 day Company Name:

tompany Name:f

\\ \\'1.

ingrowth period.

/? h>,e.-e;:,v- -

'~

Relinquished by:

DatelTime Received by:

lvv, Date/Time

\\'l,{*\\.'3 Verified By:

Company Name:

Company Name: 1 Pr

~

\\ 600

~

~

N >

Page 6 of 22 1

2 3

4 5

6 7

8 9

10 11 12 Procedure HDP-PR-QA-006, Chain of Custody Hematite Decommissioning Project Revision: 3 I

Page 1 of 1 Westinghouse Non-Proprietary Class 3 FORM HDP-PR-QA-006-1 CHAIN OF CUSTODY Instructions: Each tirne the container is transferred to another organization, a person frorn each organization should sign the Coe. The Laboratory/End User must verify that the sample is correctly identified before the sample is released for use or analysis and send the completed CoC to HDP.

Chain of Cutodv ID No.

F-120513-01 Pa~e 2/2 Reauested Analvsis Laboratorv Name:

Project Name:

TA-MO

N I

o:j Contact Person:

~ Ji-Laboratory Address:

Gerald Rood

. c8 13715 Rider Trail North

~. *.

~.,

0 C

Phone Number:

IS Phone No.

bl) *.*..

1*

.5 C

314-810-3382 0

314-298-8566 u

Sampler Name o:j

'B Laboratory Contact Person:

-0 Scott Jenkins 8

s -

~ Joe Walker

I

~

~

' Q "ij *

~ I I

Phone No.

d

<U 708-870-8453

~

0.
0.

0

' 17.l 00 Turn Around Time g:

  • --~.. -.. =!

ro

0. "'. a Rush (7 days)

§

~ "'

~

E Sample ID Date Time Matrix Q

Remarks 0

C, E-<

0 u

L101013BSSOO 12/4/2013 15:05 s C

X X I LSA-10-10 Sys. Samples L101014BRSOO 12/4/2013 15:15 s

C X

X 1 LSA-10-10 Sys. Samples L101015BESOO 12/4/2013 9:45 s

C X

X 1 LSA-10-10 Sys. Samples Relinquished by{"'"~

Date/Time ~nh~

Date/Time Total Cooler Temperature:

15 4 nporpp<, C r~

~

,1:'"',(:;'77 Company Name; I l 2..-&-R>-

lftompan~d:

Cooler ID: Shipper and Number:

-" JC/

I °?'

1r:m~

(

l')()<;_fl?

Received by:

Date/Time l~q~~by;a_d,,,,

D0/Tim.e Comments: Please analyze the samples for Tc-99 on a 7 day Company Name:

,1 to~anyName~.?

,i,,.,1~i TAT. Please analyze the samples for gamma spec after a 21 day Cl ~~V"'a ingrowth period.

Relinquished by:

Date/Time Received by: ~

Date/Time J'l* t;-\\3 Verified By:

Company Name:

CompanyName: i'ft

\\~ti

/'"

~

  • Login Sample Receipt Checklist Client: Westinghouse Electric Company LLC Job Number: 160-4779-1 Login Number: 4779 Question Answer Comment Creator: Daniels, Brian J List Source: TestAmerica St. Louis List Number: 1 True Radioactivity wasn't checked or is </= background as measured by a survey meter.

True The cooler's custody seal, if present, is intact.

N/A Sample custody seals, if present, are intact.

True The cooler or samples do not appear to have been compromised or tampered with.

False Samples were received on ice.

True Cooler Temperature is acceptable.

True Cooler Temperature is recorded.

True COC is present.

True COC is filled out in ink and legible.

True COC is filled out with all pertinent information.

True Is the Field Sampler's name present on COC?

True There are no discrepancies between the containers received and the COC.

True Samples are received within Holding Time.

True Sample containers have legible labels.

True Containers are not broken or leaking.

True Sample collection date/times are provided.

True Appropriate sample containers are used.

True Sample bottles are completely filled.

True Sample Preservation Verified.

True There is sufficient vol. for all requested analyses, incl. any requested MS/MSDs N/A Containers requiring zero headspace have no headspace or bubble is

<6mm (1/4").

True Multiphasic samples are not present.

True Samples do not require splitting or compositing.

N/A Residual Chlorine Checked.

TestAmerica St. Louis Page 7 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Definitions/Glossary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Qualifiers Metals Qualifier Description J

Result is less than the RL but greater than or equal to the MDL and the concentration is an approximate value.

Qualifier Rad Qualifier Description U

Indicates the analyte was analyzed for but not detected.

Qualifier Glossary These commonly used abbreviations may or may not be present in this report.

Listed under the "D" column to designate that the result is reported on a dry weight basis Abbreviation

%R Percent Recovery CNF Contains no Free Liquid DER Duplicate error ratio (normalized absolute difference)

Dil Fac Dilution Factor DL, RA, RE, IN Indicates a Dilution, Re-analysis, Re-extraction, or additional Initial metals/anion analysis of the sample DLC Decision level concentration MDA Minimum detectable activity EDL Estimated Detection Limit MDC Minimum detectable concentration MDL Method Detection Limit ML Minimum Level (Dioxin)

NC Not Calculated ND Not detected at the reporting limit (or MDL or EDL if shown)

PQL Practical Quantitation Limit QC Quality Control RER Relative error ratio RL Reporting Limit or Requested Limit (Radiochemistry)

RPD Relative Percent Difference, a measure of the relative difference between two points TEF Toxicity Equivalent Factor (Dioxin)

TEQ Toxicity Equivalent Quotient (Dioxin)

TestAmerica St. Louis Page 8 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Method Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method Method Description Laboratory Protocol SW846 6020A Metals (ICP/MS), Tc-99 TAL SL EPA Moisture Percent Moisture TAL SL SW846 6020A Metals (ICP/MS), Tc-99 in Activity TAL SL Protocol

References:

EPA = US Environmental Protection Agency SW846 = "Test Methods For Evaluating Solid Waste, Physical/Chemical Methods", Third Edition, November 1986 And Its Updates.

Laboratory

References:

TAL SL = TestAmerica St. Louis, 13715 Rider Trail North, Earth City, MO 63045, TEL (314)298-8566 TestAmerica St. Louis Page 9 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Sample Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID Client Sample ID Received Collected Matrix 160-4779-1 L101001BRS00 Solid 12/04/13 10:15 12/05/13 18:00 160-4779-2 L101002BES00 Solid 12/04/13 10:20 12/05/13 18:00 160-4779-3 L101003BRS00 Solid 12/04/13 10:45 12/05/13 18:00 160-4779-4 L101005BRS00 Solid 12/04/13 11:00 12/05/13 18:00 160-4779-5 L101006BES00 Solid 12/04/13 11:05 12/05/13 18:00 160-4779-6 L101007BRS00 Solid 12/04/13 13:55 12/05/13 18:00 160-4779-7 L101008BES00 Solid 12/04/13 14:00 12/05/13 18:00 160-4779-8 L101009BSS00 Solid 12/04/13 14:10 12/05/13 18:00 160-4779-9 L101010BRS00 Solid 12/04/13 14:25 12/05/13 18:00 160-4779-10 L101011BSQ00 Solid 12/04/13 14:45 12/05/13 18:00 160-4779-11 L101011BSS00 Solid 12/04/13 14:45 12/05/13 18:00 160-4779-12 L101012BRS00 Solid 12/04/13 14:55 12/05/13 18:00 160-4779-13 L101013BSS00 Solid 12/04/13 15:05 12/05/13 18:00 160-4779-14 L101014BRS00 Solid 12/04/13 15:15 12/05/13 18:00 160-4779-15 L101015BES00 Solid 12/04/13 09:45 12/05/13 18:00 TestAmerica St. Louis Page 10 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4779-1 Client Sample ID: L101001BRS00 Matrix: Solid Date Collected: 12/04/13 10:15 Percent Solids: 83.9 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 14:26 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.239 (2+/-)

0.0770 (2+/-)

1 12/11/13 14:26 12/10/13 13:58 pCi/g 0.226 1.32 RL MDC 0.0666 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 14:26 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 91 Lab Sample ID: 160-4779-2 Client Sample ID: L101002BES00 Matrix: Solid Date Collected: 12/04/13 10:20 Percent Solids: 83.5 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 14:38 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.0714 U

(2+/-)

0.0432 (2+/-)

1 12/11/13 14:38 12/10/13 13:58 pCi/g 0.224 1.31 RL MDC 0.0389 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 14:38 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 91 Lab Sample ID: 160-4779-3 Client Sample ID: L101003BRS00 Matrix: Solid Date Collected: 12/04/13 10:45 Percent Solids: 83.5 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000022 J

0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 14:42 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.381 (2+/-)

0.0716 (2+/-)

1 12/11/13 14:42 12/10/13 13:58 pCi/g 0.226 1.32 RL MDC 0.0544 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 14:42 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 TestAmerica St. Louis Page 11 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4779-4 Client Sample ID: L101005BRS00 Matrix: Solid Date Collected: 12/04/13 11:00 Percent Solids: 83.0 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000026 J

0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 14:53 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.444 (2+/-)

0.106 (2+/-)

1 12/11/13 14:53 12/10/13 13:58 pCi/g 0.227 1.33 RL MDC 0.0873 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 14:53 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 91 Lab Sample ID: 160-4779-5 Client Sample ID: L101006BES00 Matrix: Solid Date Collected: 12/04/13 11:05 Percent Solids: 83.8 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000052 J

0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 14:57 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.886 (2+/-)

0.193 (2+/-)

1 12/11/13 14:57 12/10/13 13:58 pCi/g 0.226 1.32 RL MDC 0.154 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 14:57 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-6 Client Sample ID: L101007BRS00 Matrix: Solid Date Collected: 12/04/13 13:55 Percent Solids: 89.6 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000062 0.000019 mg/Kg

12/10/13 13:58 12/11/13 15:01 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.103 U

(2+/-)

0.0688 (2+/-)

1 12/11/13 15:01 12/10/13 13:58 pCi/g 0.213 1.24 RL MDC 0.0614 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:01 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-7 Client Sample ID: L101008BES00 Matrix: Solid Date Collected: 12/04/13 14:00 Percent Solids: 83.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000066 0.000020 mg/Kg

12/13/13 10:09 12/15/13 19:29 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier TestAmerica St. Louis Page 12 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4779-7 Client Sample ID: L101008BES00 Matrix: Solid Date Collected: 12/04/13 14:00 Percent Solids: 83.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.0778 U

(2+/-)

0.0417 (2+/-)

1 12/15/13 19:29 12/13/13 10:09 pCi/g 0.227 1.33 RL MDC

-0.0369 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/13/13 10:09 12/15/13 19:29 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-8 Client Sample ID: L101009BSS00 Matrix: Solid Date Collected: 12/04/13 14:10 Percent Solids: 85.1 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000064 0.000019 mg/Kg

12/10/13 13:58 12/11/13 15:09 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.124 U

(2+/-)

0.0348 (2+/-)

1 12/11/13 15:09 12/10/13 13:58 pCi/g 0.219 1.28 RL MDC 0.0299 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:09 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 92 Lab Sample ID: 160-4779-9 Client Sample ID: L101010BRS00 Matrix: Solid Date Collected: 12/04/13 14:25 Percent Solids: 86.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000065 0.000019 mg/Kg

12/10/13 13:58 12/11/13 15:13 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.0419 U

(2+/-)

0.0706 (2+/-)

1 12/11/13 15:13 12/10/13 13:58 pCi/g 0.221 1.29 RL MDC 0.0637 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:13 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-10 Client Sample ID: L101011BSQ00 Matrix: Solid Date Collected: 12/04/13 14:45 Percent Solids: 86.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000022 J

0.000064 0.000019 mg/Kg

12/10/13 13:58 12/11/13 15:17 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier TestAmerica St. Louis Page 13 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4779-10 Client Sample ID: L101011BSQ00 Matrix: Solid Date Collected: 12/04/13 14:45 Percent Solids: 86.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.381 (2+/-)

0.0637 (2+/-)

1 12/11/13 15:17 12/10/13 13:58 pCi/g 0.221 1.29 RL MDC 0.0456 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:17 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-11 Client Sample ID: L101011BSS00 Matrix: Solid Date Collected: 12/04/13 14:45 Percent Solids: 86.8 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 0.000029 J

0.000064 0.000019 mg/Kg

12/10/13 13:58 12/11/13 15:20 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.502 (2+/-)

0.0937 (2+/-)

1 12/11/13 15:20 12/10/13 13:58 pCi/g 0.218 1.27 RL MDC 0.0707 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:20 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 Lab Sample ID: 160-4779-12 Client Sample ID: L101012BRS00 Matrix: Solid Date Collected: 12/04/13 14:55 Percent Solids: 84.2 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000067 0.000020 mg/Kg

12/10/13 13:58 12/11/13 15:24 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.0606 U

(2+/-)

0.0881 (2+/-)

1 12/11/13 15:24 12/10/13 13:58 pCi/g 0.228 1.33 RL MDC 0.0780 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:24 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 89 Lab Sample ID: 160-4779-13 Client Sample ID: L101013BSS00 Matrix: Solid Date Collected: 12/04/13 15:05 Percent Solids: 82.8 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000066 0.000020 mg/Kg

12/10/13 13:58 12/11/13 15:28 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier TestAmerica St. Louis Page 14 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Client Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Lab Sample ID: 160-4779-13 Client Sample ID: L101013BSS00 Matrix: Solid Date Collected: 12/04/13 15:05 Percent Solids: 82.8 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.223 U

(2+/-)

0.0429 (2+/-)

1 12/11/13 15:28 12/10/13 13:58 pCi/g 0.225 1.31 RL MDC 0.0337 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:28 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 92 Lab Sample ID: 160-4779-14 Client Sample ID: L101014BRS00 Matrix: Solid Date Collected: 12/04/13 15:15 Percent Solids: 85.3 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000067 0.000020 mg/Kg

12/10/13 13:58 12/11/13 15:40 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99 0.00822 U

(2+/-)

0.0341 (2+/-)

1 12/11/13 15:40 12/10/13 13:58 pCi/g 0.228 1.33 RL MDC 0.0302 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:40 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 88 Lab Sample ID: 160-4779-15 Client Sample ID: L101015BES00 Matrix: Solid Date Collected: 12/04/13 09:45 Percent Solids: 80.6 Date Received: 12/05/13 18:00 Method: 6020A - Metals (ICP/MS), Tc-99 RL MDL Technetium 99 ND 0.000070 0.000021 mg/Kg

12/10/13 13:58 12/11/13 15:44 1

Analyte Dil Fac Analyzed Prepared Unit D

Result Qualifier Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Analyte Technetium 99

-0.00833 U

(2+/-)

0.0348 (2+/-)

1 12/11/13 15:44 12/10/13 13:58 pCi/g 0.238 1.39 RL MDC

-0.0312 Dil Fac Analyzed Prepared Unit Result Qualifier Count Total Uncert.

Uncert.

Re 30 - 110 Carrier 12/10/13 13:58 12/11/13 15:44 1

Dil Fac Analyzed Prepared Qualifier Limits

%Yield 90 TestAmerica St. Louis Page 15 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 Client Sample ID: Method Blank Lab Sample ID: MB 160-90986/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 91401 Prep Batch: 90986 RL MDL Technetium 99 ND 0.000053 0.000016 mg/Kg 12/10/13 13:58 12/11/13 14:18 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-90986/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 91401 Prep Batch: 90986 Technetium 99 0.00234 0.00239 mg/Kg 102 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: L101001BRS00 Lab Sample ID: 160-4779-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 91401 Prep Batch: 90986 Technetium 99 ND 0.00278 0.00291 mg/Kg 105 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: L101001BRS00 Lab Sample ID: 160-4779-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 91401 Prep Batch: 90986 Technetium 99 ND 0.00279 0.00282 mg/Kg 101 75 - 125 3

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD Client Sample ID: Method Blank Lab Sample ID: MB 160-91733/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 92196 Prep Batch: 91733 RL MDL Technetium 99 ND 0.000054 0.000016 mg/Kg 12/13/13 10:09 12/15/13 17:44 1

MB MB Analyte Dil Fac Analyzed Prepared D

Unit Result Qualifier Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-91733/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 92196 Prep Batch: 91733 Technetium 99 0.00233 0.00236 mg/Kg 101 80 - 120 Analyte LCS LCS D

Unit Result Qualifier

%Rec Spike Added

%Rec.

Limits Client Sample ID: Matrix Spike Lab Sample ID: 160-4881-A-1-B MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 92196 Prep Batch: 91733 Technetium 99 0.00022 0.00260 0.00274 mg/Kg 97 75 - 125

Analyte MS MS D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4881-A-1-C MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 92196 Prep Batch: 91733 Technetium 99 0.00022 0.00259 0.00266 mg/Kg 94 75 - 125 3

30

Analyte MSD MSD D

Unit Result Qualifier

%Rec Spike Added Sample Result Sample Qualifier

%Rec.

Limits Limit RPD RPD TestAmerica St. Louis Page 16 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Client Sample ID: Method Blank Lab Sample ID: MB 160-90986/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 91402 Prep Batch: 90986 Technetium 99 Analyte U

1 12/11/13 14:18 12/10/13 13:58 pCi/g 0.181 MDC 1.06 RL 0.0440

-0.0417 (2+/-)

(2+/-)

MB

-0.02880 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total Carrier Re 30 - 110 12/10/13 13:58 12/11/13 14:18 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 95 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-90986/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 91402 Prep Batch: 90986 Technetium 99 Analyte 120 80 102 40.97 40.1 3.95 1.03 0.176 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 97 LCS Client Sample ID: L101001BRS00 Lab Sample ID: 160-4779-1 MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 91402 Prep Batch: 90986 Technetium 99 Analyte 125 75 104 49.84 47.6 0.239 5.26 1.28 0.218 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 93 MS Client Sample ID: L101001BRS00 Lab Sample ID: 160-4779-1 MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 91402 Prep Batch: 90986 Technetium 99 Analyte 1

0.16 125 75 100 48.24 47.8 0.239 4.81 1.29 0.221 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 93 MSD Client Sample ID: Method Blank Lab Sample ID: MB 160-91733/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 92197 Prep Batch: 91733 Technetium 99 Analyte U

1 12/15/13 17:44 12/13/13 10:09 pCi/g 0.184 MDC 1.07 RL 0.0289

-0.0262 (2+/-)

(2+/-)

MB

-0.07048 MB Dil Fac Prepared Analyzed Unit Result Qualifier Uncert.

Count Uncert.

Total TestAmerica St. Louis Page 17 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Sample Results TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity (Continued)

Client Sample ID: Method Blank Lab Sample ID: MB 160-91733/1-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 92197 Prep Batch: 91733 Carrier Re 30 - 110 12/13/13 10:09 12/15/13 17:44 1

Dil Fac Prepared Analyzed Qualifier Limits

%Yield 93 MB MB Client Sample ID: Lab Control Sample Lab Sample ID: LCS 160-91733/2-A Matrix: Solid Prep Type: Total/NA Analysis Batch: 92197 Prep Batch: 91733 Technetium 99 Analyte 120 80 101 40.37 39.9 4.16 1.07 0.184 RL MDC (2+/-)

LCS LCS pCi/g Unit Result Qual

%Rec Added Spike Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 LCS Qualifier Limits

%Yield 93 LCS Client Sample ID: Matrix Spike Lab Sample ID: 160-4881-A-1-B MS Matrix: Solid Prep Type: Total/NA Analysis Batch: 92197 Prep Batch: 91733 Technetium 99 Analyte 125 75 97 46.95 44.6 3.84 5.67 1.30 0.222 RL MDC (2+/-)

MS MS pCi/g Unit Result Qual

%Rec Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total Re Carrier 30 - 110 MS Qualifier Limits

%Yield 86 MS Client Sample ID: Matrix Spike Duplicate Lab Sample ID: 160-4881-A-1-C MSD Matrix: Solid Prep Type: Total/NA Analysis Batch: 92197 Prep Batch: 91733 Technetium 99 Analyte 1

0.14 125 75 94 45.54 44.3 3.84 4.77 1.23 0.210 RL MDC (2+/-)

MSD MSD pCi/g Unit Result Qual

%Rec Limit Added Spike Result Sample Sample Qual Limits

%Rec.

Uncert.

Total RER RER Re Carrier 30 - 110 MSD Qualifier Limits

%Yield 90 MSD TestAmerica St. Louis Page 18 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Metals Prep Batch: 90986 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4779-1 L101001BRS00 Total/NA Solid None 160-4779-1 MS L101001BRS00 Total/NA Solid None 160-4779-1 MSD L101001BRS00 Total/NA Solid None 160-4779-2 L101002BES00 Total/NA Solid None 160-4779-3 L101003BRS00 Total/NA Solid None 160-4779-4 L101005BRS00 Total/NA Solid None 160-4779-5 L101006BES00 Total/NA Solid None 160-4779-6 L101007BRS00 Total/NA Solid None 160-4779-8 L101009BSS00 Total/NA Solid None 160-4779-9 L101010BRS00 Total/NA Solid None 160-4779-10 L101011BSQ00 Total/NA Solid None 160-4779-11 L101011BSS00 Total/NA Solid None 160-4779-12 L101012BRS00 Total/NA Solid None 160-4779-13 L101013BSS00 Total/NA Solid None 160-4779-14 L101014BRS00 Total/NA Solid None 160-4779-15 L101015BES00 Total/NA Solid None LCS 160-90986/2-A Lab Control Sample Total/NA Solid None MB 160-90986/1-A Method Blank Total/NA Analysis Batch: 91401 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 90986 160-4779-1 L101001BRS00 Total/NA Solid 6020A 90986 160-4779-1 MS L101001BRS00 Total/NA Solid 6020A 90986 160-4779-1 MSD L101001BRS00 Total/NA Solid 6020A 90986 160-4779-2 L101002BES00 Total/NA Solid 6020A 90986 160-4779-3 L101003BRS00 Total/NA Solid 6020A 90986 160-4779-4 L101005BRS00 Total/NA Solid 6020A 90986 160-4779-5 L101006BES00 Total/NA Solid 6020A 90986 160-4779-6 L101007BRS00 Total/NA Solid 6020A 90986 160-4779-8 L101009BSS00 Total/NA Solid 6020A 90986 160-4779-9 L101010BRS00 Total/NA Solid 6020A 90986 160-4779-10 L101011BSQ00 Total/NA Solid 6020A 90986 160-4779-11 L101011BSS00 Total/NA Solid 6020A 90986 160-4779-12 L101012BRS00 Total/NA Solid 6020A 90986 160-4779-13 L101013BSS00 Total/NA Solid 6020A 90986 160-4779-14 L101014BRS00 Total/NA Solid 6020A 90986 160-4779-15 L101015BES00 Total/NA Solid 6020A 90986 LCS 160-90986/2-A Lab Control Sample Total/NA Solid 6020A 90986 MB 160-90986/1-A Method Blank Total/NA Prep Batch: 91733 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4779-7 L101008BES00 Total/NA Solid None 160-4881-A-1-B MS Matrix Spike Total/NA Solid None 160-4881-A-1-C MSD Matrix Spike Duplicate Total/NA Solid None LCS 160-91733/2-A Lab Control Sample Total/NA Solid None MB 160-91733/1-A Method Blank Total/NA Analysis Batch: 92196 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 91733 160-4779-7 L101008BES00 Total/NA TestAmerica St. Louis Page 19 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Metals (Continued)

Analysis Batch: 92196 (Continued)

Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid 6020A 91733 160-4881-A-1-B MS Matrix Spike Total/NA Solid 6020A 91733 160-4881-A-1-C MSD Matrix Spike Duplicate Total/NA Solid 6020A 91733 LCS 160-91733/2-A Lab Control Sample Total/NA Solid 6020A 91733 MB 160-91733/1-A Method Blank Total/NA General Chemistry Analysis Batch: 90314 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid Moisture 160-4779-1 L101001BRS00 Total/NA Solid Moisture 160-4779-1 DU L101001BRS00 Total/NA Solid Moisture 160-4779-2 L101002BES00 Total/NA Solid Moisture 160-4779-3 L101003BRS00 Total/NA Solid Moisture 160-4779-4 L101005BRS00 Total/NA Solid Moisture 160-4779-5 L101006BES00 Total/NA Solid Moisture 160-4779-6 L101007BRS00 Total/NA Solid Moisture 160-4779-7 L101008BES00 Total/NA Solid Moisture 160-4779-8 L101009BSS00 Total/NA Solid Moisture 160-4779-9 L101010BRS00 Total/NA Solid Moisture 160-4779-10 L101011BSQ00 Total/NA Solid Moisture 160-4779-11 L101011BSS00 Total/NA Solid Moisture 160-4779-12 L101012BRS00 Total/NA Solid Moisture 160-4779-13 L101013BSS00 Total/NA Solid Moisture 160-4779-14 L101014BRS00 Total/NA Solid Moisture 160-4779-15 L101015BES00 Total/NA Solid Moisture 680-96831-A-4 MS Matrix Spike Total/NA Solid Moisture 680-96831-A-4 MSD Matrix Spike Duplicate Total/NA Rad Prep Batch: 90986 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4779-1 L101001BRS00 Total/NA Solid None 160-4779-1 MS L101001BRS00 Total/NA Solid None 160-4779-1 MSD L101001BRS00 Total/NA Solid None 160-4779-2 L101002BES00 Total/NA Solid None 160-4779-3 L101003BRS00 Total/NA Solid None 160-4779-4 L101005BRS00 Total/NA Solid None 160-4779-5 L101006BES00 Total/NA Solid None 160-4779-6 L101007BRS00 Total/NA Solid None 160-4779-8 L101009BSS00 Total/NA Solid None 160-4779-9 L101010BRS00 Total/NA Solid None 160-4779-10 L101011BSQ00 Total/NA Solid None 160-4779-11 L101011BSS00 Total/NA Solid None 160-4779-12 L101012BRS00 Total/NA Solid None 160-4779-13 L101013BSS00 Total/NA Solid None 160-4779-14 L101014BRS00 Total/NA Solid None 160-4779-15 L101015BES00 Total/NA Solid None LCS 160-90986/2-A Lab Control Sample Total/NA Solid None MB 160-90986/1-A Method Blank Total/NA TestAmerica St. Louis Page 20 of 22 1

2 3

4 5

6 7

8 9

10 11 12

QC Association Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Rad (Continued)

Prep Batch: 91733 Lab Sample ID Client Sample ID Prep Type Matrix Method Prep Batch Solid None 160-4779-7 L101008BES00 Total/NA Solid None 160-4881-A-1-B MS Matrix Spike Total/NA Solid None 160-4881-A-1-C MSD Matrix Spike Duplicate Total/NA Solid None LCS 160-91733/2-A Lab Control Sample Total/NA Solid None MB 160-91733/1-A Method Blank Total/NA TestAmerica St. Louis Page 21 of 22 1

2 3

4 5

6 7

8 9

10 11 12

Tracer/Carrier Summary TestAmerica Job ID: 160-4779-1 Client: Westinghouse Electric Company LLC Project/Site: RFP-CBA-022 (7 DAY TAT)

Method: 6020A - Metals (ICP/MS), Tc-99 in Activity Prep Type: Total/NA Matrix: Solid Lab Sample ID Client Sample ID (30-110)

Re 91 160-4779-1 Percent Yield (Acceptance Limits)

L101001BRS00 93 160-4779-1 MS L101001BRS00 93 160-4779-1 MSD L101001BRS00 91 160-4779-2 L101002BES00 90 160-4779-3 L101003BRS00 91 160-4779-4 L101005BRS00 90 160-4779-5 L101006BES00 90 160-4779-6 L101007BRS00 90 160-4779-7 L101008BES00 92 160-4779-8 L101009BSS00 90 160-4779-9 L101010BRS00 90 160-4779-10 L101011BSQ00 90 160-4779-11 L101011BSS00 89 160-4779-12 L101012BRS00 92 160-4779-13 L101013BSS00 88 160-4779-14 L101014BRS00 90 160-4779-15 L101015BES00 86 160-4881-A-1-B MS Matrix Spike 90 160-4881-A-1-C MSD Matrix Spike Duplicate 97 LCS 160-90986/2-A Lab Control Sample 93 LCS 160-91733/2-A Lab Control Sample 95 MB 160-90986/1-A Method Blank 93 MB 160-91733/1-A Method Blank Tracer/Carrier Legend Re = Re TestAmerica St. Louis Page 22 of 22 1

2 3

4 5

6 7

8 9

10 11 12