MONTHYEARAEP-NRC-2015-46, License Amendment Request to Adopt TSTF-425-A, Rev. 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force Initiative 5B2015-11-19019 November 2015 License Amendment Request to Adopt TSTF-425-A, Rev. 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force Initiative 5B Project stage: Request AEP-NRC-2016-17, Supplement to License Amendment Request to Adopt TSTF-425-A, Revision 3, Relocate Surveillance Frequencies to License Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5B.2016-02-0404 February 2016 Supplement to License Amendment Request to Adopt TSTF-425-A, Revision 3, Relocate Surveillance Frequencies to License Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5B. Project stage: Supplement ML16127A0792016-05-11011 May 2016 Request for Additional Information Regarding License Amendment Request to Relocate Surveillance Frequencies to Licensee Control Project stage: RAI ML16154A1822016-06-0909 June 2016 Request for Additional Information Regarding License Amendment Request to Relocate Surveillance Frequencies to Licensee Control (CAC Nos. MF7114 and MF7115) Project stage: RAI AEP-NRC-2016-48, Unit 2 - Response to Request for Additional Information Regarding the License Amendment Request to Adopt TSTF-425, Relocate Surveillance Frequencies Program to Licensee-Control...2016-06-16016 June 2016 Unit 2 - Response to Request for Additional Information Regarding the License Amendment Request to Adopt TSTF-425, Relocate Surveillance Frequencies Program to Licensee-Control... Project stage: Response to RAI ML16211A0152016-08-0101 August 2016 Follow-Up Request for Additional Information Regarding License Amendment Request to Relocate Surveillance Frequencies to Licensee Control Project stage: RAI AEP-NRC-2016-69, Follow-up Response to Request for Additional Information Regarding License Amendment Request to Adopt TSTF-425, Relocate Surveillance Frequencies Program to License Control-Risk Informed Technical Specification Task Force.2016-09-0909 September 2016 Follow-up Response to Request for Additional Information Regarding License Amendment Request to Adopt TSTF-425, Relocate Surveillance Frequencies Program to License Control-Risk Informed Technical Specification Task Force. Project stage: Response to RAI AEP-NRC-2016-88, Withdrawal of Emergency License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source- Operating2016-10-13013 October 2016 Withdrawal of Emergency License Amendment Request for One-Time Extension of Completion Time for Inoperable AC Source- Operating Project stage: Withdrawal ML16308A1132016-11-16016 November 2016 Summary of October 27, 2016, Public Meeting with Indiana Michigan Power Company Regarding the Donald C. Cook Nuclear Plant, Units 1 and 2 Project stage: Meeting ML17045A1502017-03-31031 March 2017 Issuance of Amendments Adopting of TSTF0425-A, Revision 3, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B Project stage: Approval 2016-05-11
[Table View] |
Similar Documents at Cook |
---|
Category:Meeting Summary
MONTHYEARML23215A1662023-08-17017 August 2023 Summary of July 31, 2023, Meeting with Indiana Michigan Power Company Regarding Operating Power Sources for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML23199A2402023-07-19019 July 2023 Summary of the July 13, 2023, Public Outreach to Discuss the NRC 2022 End-of-Cycle Plant Performance Assessment of Donald C. Cook Nuclear Plant, Units 1 and 2 ML22355A6022023-01-0303 January 2023 Summary of December 14, 2022, with Indiana Michigan Power Company to Discuss Potential Changes to the Emergency Plan for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML22318A1992022-11-21021 November 2022 Summary of November 7, 2022, Meeting with Indiana Michigan Power Company Regarding Neutron Flux Instrumentation for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML22154A5342022-06-0909 June 2022 Summary of the June 1, 2022, Public Outreach to Discuss the NRC 2021 End-Of-Cycle Plant Performance Assessment of Donald C. Cook Nuclear Plant ML22011A2732022-01-13013 January 2022 Summary of Meeting with Indiana Michigan Power Company to Discuss Planned Final Response to Generic Letter 2004-02 for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML21349B3092022-01-0303 January 2022 Summary of Meeting with Indiana Michigan Power Company to Discuss Potential Changes to the Quality Assurance Program for Donald C. Cook Nuclear Plant, Units 1 and 2 ML21202A1072021-07-23023 July 2021 Summary of July 20, 2021, with Indiana Michigan Power Company to Discuss Potential Changes to the Emergency Plan for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML21196A5182021-07-15015 July 2021 July 8, 2021, Summary of Public Webinar to Discuss the NRC 2020 End-Of-Cycle Plant Performance Assessment of the Donald C. Cook Nuclear Plant ML21082A0052021-03-24024 March 2021 Summary of March 19, 2021, with Indiana Michigan Power Company Regarding Containment Water Level Channels for Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML20349A0152020-12-17017 December 2020 Summary of November 30, 2020, Teleconference with Indiana Michigan Power Company Regarding a Planned License Amendment Request to Extend the Containment Integrated Leak Rate Testing Interval for Donald C. Cook Nuclear Plant, Unit No. 2 ML20282A2712020-10-14014 October 2020 Summary of October 2, 2020, Teleconference with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit No. 1 ML20248H4752020-09-10010 September 2020 Summary of August 6, 2020, Teleconference with Indian Michigan Power Company Related to Steam Generator Eddy Current Testing License Amendment Request ML20209A6032020-07-27027 July 2020 Summary of the July 21, 2020, Public Webinar to Discuss the NRC 2019 End-of-Cycle Plant Performance Assessment of the Donald C. Cook Nuclear Plant, Units 1 and 2 ML20133K1282020-05-21021 May 2020 Summary of May 4, 2020, Teleconference with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML20121A0692020-05-0404 May 2020 Summary of Teleconference with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML20041C9492020-02-13013 February 2020 Summary of February 6, 2020, Teleconference with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML19350A0552019-12-30030 December 2019 Summary of 12/12/2019 Meeting with Indiana Michigan Power Company, License Amendment Request for D.C. Cook Nuclear Plant, Units 1 and 2 to Delete Surveillance Requirement Related to Diesel Generator Load Test Resistor Banks ML19212A5652019-07-30030 July 2019 Summary of Public Open House to Discuss NRC Activities and the 2018 End-Of-Cycle Performance Assessment of Donald C. Cook Nuclear Generating Plant, Units 1 and 2 ML19141A0622019-06-0606 June 2019 Summary of November 19, 2018, Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML19099A3262019-04-16016 April 2019 Summary of Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML19067A0482019-03-12012 March 2019 Summary of Public Teleconference with Indiana Michigan Power Co. (I&M) Review of LAR for Approval of Leak-Before-Break Methodology for Reactor Coolant System Small Diameter Piping (EPID-2019-LLA-0054) ML18334A0402018-12-13013 December 2018 Summary of Meeting with Indian Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit No. 1 ML18109A0692018-04-26026 April 2018 Summary of April 10, 2018, Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML18052B0542018-02-26026 February 2018 Summary of February 15, 2018, Meeting with Indian Michigan Power Company Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 (EPID L-2018-LRM-0008 ML18018B1382018-01-22022 January 2018 Summary of Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit No. 1 ML17265A4922017-10-0404 October 2017 Summary of Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 2 ML17235B1232017-08-23023 August 2017 Summary of the July 27, 2017, Open House to Discuss the 2016 End-of-Cycle Plant Performance Assessment of Donald C. Cook Nuclear Plant ML17082A0762017-03-27027 March 2017 Summary of March 20, 2017, Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Unit Nos. 1 and 2 ML16308A1132016-11-16016 November 2016 Summary of October 27, 2016, Public Meeting with Indiana Michigan Power Company Regarding the Donald C. Cook Nuclear Plant, Units 1 and 2 ML16244A7062016-08-30030 August 2016 Summary of the August 22, 2016, Donald C. Cook Public Meeting ML16193A5912016-07-15015 July 2016 Summary of Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Units 1 and 2 ML15271A0462015-10-0505 October 2015 Summary of Public Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Units 1 and 2 ML15237A3362015-09-0202 September 2015 Summary of August 24, 2015, Telephone Call to Provide Verbal Authorization of Relief Request ISIR-4-06, Alternate Repair of Socket Weld ML15107A0982015-04-24024 April 2015 April 14, 2015, Summary of Meeting with Indiana Michigan Power Company Regarding Donald C. Cook Nuclear Plant, Units 1 and 2 ML14311A3182014-11-14014 November 2014 Summary of Conference Call with Donald C. Cook Nuclear Plant, Unit 1 Regarding the Fall 2014 Steam Generator Inspections ML14231A0752014-08-27027 August 2014 Summary of the August 8, 2014, Pre-Application Meeting with American Electric Power Company to Discuss a Future License Amendment Request for Alternative Source Term and TSTF-490 ML14209A9422014-07-30030 July 2014 July 9, 2014, Summary of Category 1, Public Meeting with Indiana Michigan Power Company to Discuss Seismic Hazard Reevaluations Associated with Implementation of Japan Lessons-Learned Near-Term Task Force Recommendation 2.1 ML14199A0802014-07-18018 July 2014 Summary of July 8, 2014 Donald C. Cook Public Annual Assessment Meeting ML14023A3872014-01-30030 January 2014 Summary of Joint Steering Committee Meeting to Discuss Activities Related to Lessons-Learned from the Fukushima Dai-Ichi Nuclear Power Plant Event ML13210A2272013-08-0202 August 2013 6/26/13, Summary of Pre-Application Meeting to Discuss Pending License Amendment Request to Modify the CNP Unit 1 Normal Operating Pressure and Temperature ML13189A2322013-07-15015 July 2013 Summary of Conference Telephone Call Regarding the 2013 Steam Generator Tube Inspections ML13154A4062013-06-0303 June 2013 5/30/2013 - Summary of the D.C. Cook Public Meeting ML12159A4022012-06-0707 June 2012 May 31, 2012 Summary of Public Meeting to Discuss the 2011 Annual Assessment Results for D.C. Cook ML1133307782011-11-29029 November 2011 Record of Discussion by Phone on 10/5/11 Regarding Steam Generator Inspection ML11129A2422011-06-0808 June 2011 Summary of Meeting with Indiana Michigan Power Company to Discuss Issues Related to a Future Submittal Using NFPA 805 ML0931305572009-11-0909 November 2009 Summary of Public Meeting with Staff from the D.C. Cook Nuclear Power Plant Regarding the September 2008 Unit 1 Turbine Vibration Event ML0915905922009-06-0808 June 2009 Summary of Open House to Discuss NRC Activities, Nuclear Power Issues, and the Donald C. Cook Nuclear Power Plant 2008 End-Of-Cycle Plant Performance Assessment ML0809200582008-04-18018 April 2008 Summary of Phone Call with Licensees Concerning Sump Strainer Head Loss Testing ML0811203302008-04-18018 April 2008 EOC Public Meeting Summary 2023-08-17
[Table view] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 November 16, 2016 LICENSEE: Indiana Michigan Power Company, LLC FACILITY: Donald C. Cook Nuclear Plant, Units 1 and 2
SUBJECT:
SUMMARY
OF OCTOBER 27, 2016, PUBLIC MEETING WITH INDIANA MICHIGAN POWER COMPANY REGARDING THE DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 (CAC NOS. MF7114 AND MF7115)
On October 27, 2016, a Category I public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Indiana Michigan Power Company (l&M, the licensee) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. This meeting was open to members of the public. The meeting notice and agenda, dated October 21, 2016, are available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML16295A375. A list of attendees is provided as . The licensee's presentation is provided as Enclosure 2.
Purpose The purpose of the meeting was to discuss the license amendment request (LAR) dated November 19, 2015, for the Donald C. Cook Nuclear Plant, Units 1 and 2 (ADAMS Accession No. ML15328A469). The proposed amendment is consistent with the NRG-approved Technical Specifications Task Force (TSTF) Traveler, TSTF-425, Revision 3, "Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative Sb." The proposed change would relocate surveillance frequencies to a licensee-controlled program, the Surveillance Frequency Control Program. The meeting focused on a recent upgrade to the licensee's probabilistic risk assessment (PRA), which was performed in support of the LAR.
Background
During the meeting, the NRC staff presented a background of the LAR review thus far. A summary of the background follows.
The NRC staff's review of the licensee's LAR to adopt TSTF-425 has included two requests for additional information (RAls) related to PRA. The NRC staff issued the first RAI by letter dated May 11, 2016 (ADAMS Accession No. ML16127A079). In the first RAI, the NRC requested that the licensee explain the disposition of certain facts and observations (F&Os) for pre-initiator human failure events. The licensee responded by letter dated June 16, 2016 (ADAMS Accession No. ML16173A256). In the June 16, 2016, letter, the licensee stated that it had performed a new pre-initiator Human Reliability Analysis (HRA) to resolve the F&O.
The NRC staff issued the second RAI by letter dated August 1, 2016 (ADAMS Accession No. ML16211A015). In the August 1, 2016, letter, the NRC stated that if the new analysis constituted a PRA upgrade, the licensee would need to perform a focused scope peer review and provide the F&Os to the NRC, along with their dispositions and impact on the LAR. The
licensee responded to the second RAI by letter dated September 9, 2016 (ADAMS Accession No. ML16258A145). In the September 9, 2016, letter, the licensee stated that the new pre-initiator analysis does constitute a PRA upgrade, and that a focused-scope peer review would be scheduled for the fourth quarter of 2016.
On October 11, 2016, the licensee submitted an emergency LAR (ADAMS Accession No. ML16287A615) that was unrelated to the TSTF-425 review, but that included discussion about the HRA focused scope peer review that had been recently performed. The NRC staff reviewed the information that was submitted and issued an RAI on October 13, 2016, related to the scope of review and applicability of Supporting Requirements from the PRA Standard (ADAMS Accession No. ML16291A011). The licensee then determined that it did not need the emergency amendment, and the LAR was withdrawn by letter dated October 13, 2016 (ADAMS Accession No. ML16291A496), before an RAI response was submitted to the NRC.
On October 21, 2016, a telephone conference was held to inform the licensee that the NRC staff was prepared to deny the TSTF-425 LAR, as submitted. The basis for denial was that the LAR lacked an analysis that was necessary for the NRC staff's review. Specifically, the licensee incorporated a new method into its PRA model without performing a focused scope peer review and providing the F&Os and impact assessments to the NRC. Additionally, the licensee did not fully respond to the NRC RAI dated August 1, 2016, rather the response only contained a promise for future information. On the October 21, 2016, phone call, the NRC staff offered the licensee the opportunity to withdraw the TSTF-425 LAR, or to request a public meeting for further discussion of the issues. The licensee requested a public meeting.
Technical Discussion During the meeting, the licensee presented information regarding the status of the focused scope peer review on HRA pre-initiators. The presentation given by the licensee is included as of this meeting summary. The licensee stated that it had completed a focused scope peer review of its pre-initiator HRA. The licensee provided a table of the high level requirements (HLRs) from the PRA standard, ASME/ANS RA-Sa-2009, "Standard for Level 1/Large Early Release Frequency Probabilistic Risk Assessment for Nuclear Power Plant Applications," along with the result of the focused scope peer review for each applicable HLR.
The licensee stated that the documentation for the focused scope peer review was finalized on October 11, 2016, and that a full response to the August 1, 2016, RAI could be provided by November 4, 2016. The licensee stated that it would provide a copy of the complete focused scope peer review report with the RAI response.
The NRC staff asked the licensee if the focused scope peer review had been influenced by the F&Os from the previously performed peer review. The licensee stated that the focused scope peer review was complete and independent, and had not been biased by the previous review.
The NRC staff requested that the licensee's RAI response include an explanation for any HLRs that had not been evaluated as part of the focused scope peer review.
The NRC staff stated that, following the meeting, a determination would be made whether or not to continue with the denial of the LAR. No regulatory decisions were made during the meeting.
Public Participation Members of the public were in attendance via telephone, but had no comments. Public Meeting Feedback forms were not received.
Please direct any inquiries to me at 301-415-2846, or Allison.Dietrich@nrc.gov.
Sincerely,
~()/ :ifl Allison W. Dietrich, Project Manager Plant Licensing Branch 111-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-315 and 50-316
Enclosure:
- 1. List of Attendees
- 2. Licensee Presentation cc w/encl: Distribution via Listserv
LIST OF ATTENDEES OCTOBER 27. 2016, PUBLIC MEETING WITH l&M. LLC REGARDING LICENSE AMENDMENT REQUEST TO RELOCATE SURVEILLANCE FREQUENCIES TO LICENSEE CONTROL DONALD C. COOK NUCLEAR PLANT, UNITS 1 AND 2 CAC NOS. MF7114 AND MF7115 Name Organization Eric Benner U.S. Nuclear Regulatory Commission (NRC)
David Wrona NRC Allison Dietrich NRC CJ Fong NRC Jonathan Evans NRC Leslie Fields NRC Mihaela Biro NRC John Ellegood* NRC Garill Coles* Pacific Northwest National Laboratory (PNNL)
Steve Short* PNNL Michael Scarpello Indiana Michigan Power Company (l&M)
James Heyeck l&M Helen Kish* l&M Danielle Burgoyne* l&M Brandon Irvin Jensen Huqhes Eric Thornsbury Jensen Hughes Victoria Anderson* Nuclear Enerav Institute
- Participated by phone Enclosure 1
Enclosure 2 Licensee Presentation
An Overview of the D.C. Cook 0
Focused Scope Peer Review - HRA Pre-Initiators October 27, 2016 NRC Headquarters - Rockville, MD Presented by Brandon Irvin - D.C. Cook PRA Team Eric Thornsbury - D.C. Cook PRA Team Michael Scarpello - D.C. Cook Regulatory Affairs Manager James Heyeck - D.C. Cook PRA Engineer
'-"' INOIANA iiilMICHIGAN D.C. Cook Nuclear Power Plant A unitofAmerican Elsctric Power
TSTF-425 License Amendment Request
- A License Amendment request submitted in late 2015 for adoption of Risk Informed Initiative Sb/ TSTF-425
- RAls received related to Pre-Initiators 0
RAl-PRA Noted F&Os received on pre-initiators from 2015 PRA Peer Review and questioned the intent to disposition these F&Os with PRA Sensitivities 0
RAl-PRA-1-0 I - Focus of RAI shifted to understanding if the "new analysis" was considered as a "PRA Upgrade" liiMMICHHMN
'-"' .lllDIAIU&
Annitof American Electric Power D.C. Cook Nuclear Power Plant
Focused Scope Follow-On Peer Review
- A review of NEI 05-04 and guidance provided directly from the PRA Standard RA-Sa-2009 was performed to determine the appropriate scope and level of review required.
0 As a result, the scope of the review was limited to Cook Pre-Initiator Methods against HLRs HR-A, HR-Band HR-C 0
SRs HR-A I through HR-C3 reviewed
~.llDIANA iliilil.MICHIMN D.C. Cook Nuclear Power Plant l'fJl'lm**
Aunit ofAmerican Elttctric Power
Focused Scope Follow-On Peer Review
- A Focused Scope Peer Review was performed and completed in October 2016 based on the identification of an upgrade.
° Changes made to Identification, Screening, and Definition methodology used in PRA for pre-initiators.
0 No change made to the method of quantification or documentation.
~.llDIANA
. . . MICHIGAN A unit ofAmerican Electric Pawer D.C. Cook Nuclear Power Plant
High Level Requirement Overview HLR-HR-B Screening of Pre-Initiators Upgraded- Focused Scope Peer Required Review Review Complete -
SRs Met at CC-II
.!*~'Jd~,
E~tG~~: ~~"
HLR~HR..C R~~lred Review impact of Pre-4(\ltiators SR.s. Met ltCC~U HLR-HR-D Assessment and Quantification Not Upgraded (I) N/A of Pre-Initiators HLR-HR-1 Documentation NdtUpgraded (2) NIA.
(I) Pre-initiator quantification methodologies (TH ERP and ASEP) were not changed (2) No changes made to the documentation approach as a result of changing identification and screening
~ lllDIAllA iiiil MICHIGAN D.C. Cook Nuclear Power Plant IOtllfS**
A unit ofAmerican Electric Power
Finalizing the RAI Responses
- Pre-Initiator Focused Scope PRA Peer Review was completed and final documentation approved on October I Ith 2016.
- Final RAI responses agreed to be provided by mid November can be provided as early as November 4th.
""'INOIANA
. . . MICHIGAN D.C. Cook Nuclear Power Plant
~**
A anit ofAmerican Electric Power
What will we provide
- A copy of the complete Focused Scope PRA Peer Review report
- Dispositioning of a finding received 0
Single Finding received related to documentation and verification of process used for screening however the SR was graded as Met Cat II
, . INDIAllll
. . . MICHIGAN D.C. Cook Nuclear Power Plant l'Olllfl**
A llnit of American Electric Power
ML16308A113 OFFICE DORULPL3-1 /PM DORULPL3-1/LA DRNAPLA/BC DORULPL3-1/BC DORULPL3-1 /PM NAME A Dietrich SRohrer SRosenberg DWrona A Dietrich DATE 11/3/16 11/3/16 11/14/16 11/15/16 11/16/16