Text
UNITED STATES
NUCLEAR REGULATORY COMMISSION
REGION II
245 PEACHTREE CENTER AVENUE NE, SUITE 1200
ATLANTA, GEORGIA 30303-1257
October 28, 2010
Mr. Jon A. Franke
Vice President, Crystal River Nuclear Plant
Crystal River Nuclear Plant (NA2C)
15760 W. Power Line Street
Crystal River, FL 34428-6708
SUBJECT: CRYSTAL RIVER UNIT 3 NUCLEAR GENERATING PLANT - NOTIFICATION
OF INSPECTION AND REQUEST FOR INFORMATION 05000302/2010005
Dear Mr. Franke:
During the period of December 6 - 10, 2010, the NRC will conduct baseline radiation safety
inspection activities at the Crystal River 3 Nuclear Plant. The inspection will focus on both the
Occupational and Public Radiation Safety Inspection cornerstones using NRC Inspection
Procedure (IP) 71124.01, IP 71124.04, and IP 71124.06. IP 71124.07, IP 71124.08, and
Temporary Instruction (TI) 2515/179. The inspection also will evaluate Occupational and Public
Cornerstone Radiation Safety sections of IP 711551 associated with Performance Indicator (PI)
verification.
Experience has shown that this inspection is resource intensive both for the NRC inspectors
and your staff. In order to minimize the impact to your on-site resources and to conduct a
productive inspection, we have enclosed a request for documents needed for this inspection. It
is important that all of these documents are up to date and complete, in order to minimize the
number of additional documents requested during the preparation and/or the onsite portions of
the inspection. The lead inspector has requested that the subject informational material be
made available to the NRC staff by November 26, 2010, to allow preparation for the upcoming
inspection
We have discussed the schedule for these inspection activities with your staff and understand
that our regulatory on-site contact for this inspection will be Mr. Dennis Herrin of your
organization. If there are any questions about this inspection or the material requested, please
contact the lead inspector, George B. Kuzo at (404) 997-4658.
In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its
enclosure will be available electronically for public inspection in the NRC Public Document
FPC 2
Room or from the Publicly Available Records (PARS) component of NRC's document system
(ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/ reading-
rm/adams.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Brian Bonser, Chief
Plant Support Branch 1
Division of Reactor Safety
Docket No.: 50-302
License No.: DPR-72
Enclosure: Radiation Protection Inspection Document Request
cc w/encl.: (See page 3)
FPC 3
cc w/encl:
R. J. Duncan, II Jack E. Huegel
Vice President Manager, Nuclear Oversight
Nuclear Operations Crystal River Nuclear Plant
Carolina Power & Light Company Electronic Mail Distribution
Electronic Mail Distribution
David T. Conley
Brian C. McCabe Associate General Counsel
Manager, Nuclear Regulatory Affairs Legal Dept.
Progress Energy Carolinas, Inc. Progress Energy Service Company, LLC
Electronic Mail Distribution Electronic Mail Distribution
James W. Holt Mark Rigsby
Plant General Manager Manager, Support Services - Nuclear
Crystal River Nuclear Plant (NA2C) Crystal River Nuclear Plant (NA2C)
Electronic Mail Distribution Electronic Mail Distribution
Stephen J. Cahill Senior Resident Inspector
Engineering Manager U.S. Nuclear Regulatory Commission
Crystal River Nuclear Plant (NA2C) Crystal River Nuclear Generating Plant
Electronic Mail Distribution U.S. NRC
6745 N Tallahassee Rd
R. Alexander Glenn Crystal River, FL 34428
Associate General Counsel
(MAC - BT15A) Attorney General
Florida Power Corporation Department of Legal Affairs
Electronic Mail Distribution The Capitol PL-01
Tallahassee, FL 32399-1050
Christos Kamilaris
Director Ruben D. Almaguer
Fleet Support Services Director
Carolina Power & Light Company Division of Emergency Preparedness
Electronic Mail Distribution Department of Community Affairs
Electronic Mail Distribution
William A. Passetti
Chief Chairman
Florida Bureau of Radiation Control Board of County Commissioners
Department of Health Citrus County
Electronic Mail Distribution 110 N. Apopka Avenue
Inverness, FL 36250
Daniel R. Westcott
Supervisor
Licensing & Regulatory Programs
Crystal River Nuclear Plant (NA1B)
Electronic Mail Distribution
Joseph W. Donahue
Vice President
Nuclear Oversight
Carolina Power and Light Company
Electronic Mail Distribution
_________________________ G SUNSI REVIEW COMPLETE
OFFICE RII: DRS RII:DRS
NAME G. KUZO B. BONSER
DATE 10/28/2010 10/28/2010 10/ /2010 10/ /2010 10/ /2010 10/ /2010 10/ /2010
E-MAIL COPY? YES NO YES NO YES NO YES NO YES NO YES NO YES NO
PUBLIC RADIATION PROTECTION INSPECTION
DOCUMENT REQUEST
SITE: Crystal River Unit 3 (CR3) Report Number: 05000302/2010005
INSPECTION DATES: December 6 - 10, 2010
NRC INSPECTORS: George B. Kuzo, George.Kuzo@NRC.GOV (404) 997-4658
Ruben Hamilton, Ruben.Hamilton@NRC.GOV (404) 997-4672
Wade Loo Wade.Loo@NRC.GOV (404) 997-4727
Carmen Dykes, Carmen.Dykes@NRC.GOV (404) 997-4401
PRELIMINARY LICENSEE CONTACTS: Radiation Controls - Bryan Akins, 352 464-7964[C];
ALARA - Kenny Young , 352 464-7462[C]; Transportation & Radioactive Waste Processing,
Randy Macko, [352 795-6486 X3610]; Effluents/ Process Monitors/Groundwater Monitoring -
Lee Hughes (352-563-4715/352-464-7421[C] and/or Rudy Pinner [352 795-6486 X3141]; and
Licensing - D. Herrin, 352-563-4633
Inspection Procedures: IP 71124.01 Radiological Hazard Assessment and Exposure
Controls
IP 71124.04 Occupational Dose Assessment
IP 71124.06 Radioactive Gaseous and Liquid Effluent Treatment
IP 71124.07 Radiological Environmental Monitoring Program
IP 71124.08 Radioactive Solid Waste Processing and
Radioactive Material Handling, Storage, and
Transportation
IP 71151 Performance Indicator Verification
TI 2515/179 Verification of Licensee Responses to NRC
Requirement for Inventories of Materials Tracked in
the National Source Tracking System Pursuant to
Title 10, Code of Federal Regulations, Part 20.2207
Note: This is a broad list of the documents the lead NRC inspector will be interested in
reviewing and obtaining during the pre-inspection visit. The current version of these documents
is expected unless specified otherwise. Electronic media is preferred, if readily available. (The
preferred file format is Word, WordPerfect, or searchable pdf files on electronic media, e.g.
CD-ROM. Please provide 3 copies of each electronic device that is submitted.) Information in
the document lists should contain enough information to be easily understood by someone
who has knowledge of the subject. During the inspection, the inspectors may request additional
documents.
Enclosure
2
GENERAL INFORMATION NEEDED
Organization Charts and Contact Phone Numbers for:
Radiation Protection
Chemistry
Procedure for issuing Condition Report (CR) documents and assessing issues for risk
significance and follow-up actions.
Updated Final Safety Analysis Report Chapter 11, Effluents/Radwaste; and Chapter 12
Radiation Protection
Current version/revision of the Offsite Dose Calculation Manual (ODCM)
Annual Radiological Environmental Operating Report (AREOR) for Calendar Year (CY) 08
and CY 09
Annual Radiological Effluent Release Report (ARERR) documents for CY 2008 and CY 2009
Current Part 61 Analysis Results for Dry Active Waste (DAW)
Schedule of major maintenance / operational activities during onsite inspection (Gantt chart
if available).
RADIOLOGICAL HAZARD ASSESSMENT AND EXPOSURE CONTROL [71124.01]
Provide Procedures/Guidance Documents for:
external dose monitoring, i.e., dosimetry issuance and use. The documents should
include: guidance for multi-badging; monitoring in steep/highly variable dose rate
gradients; high radiation area (HRA), locked-HRA (LHRA) and very high radiation area
(VHRA) controls for select operational / outage activities; personnel contamination events;
storage/care of personal dosimeters; use of electronic dosimeters including evaluation of
set-point determination; biases identified relative to TLD monitoring; remote monitoring
procedures; post shutdown, fuel movement, and/or diving operations
internal dose assessment, i.e., both in vivo and in vitro bioassay and air sampling
capabilities. The documents should include guidance for calibration/QC and use of whole
body counter (WBC); release of contaminated individuals, use of passive monitoring as
screening method for evaluations, and special in vitro sample collection and analysis, and
suspect alpha particle exposures.
contamination control, i.e., procedures for release of contaminated individuals or
potentially contaminated materials from the radiologically controlled area (RCA)
Posting of areas, labeling of containers, and inventories of non-SNM materials maintained
within the spent fuel pools
List five highest cumulative exposures or exposure rate tasks for current outage activities.
Provide associated radiation work permit documents, if available
List current outage tasks with significant potential for significant release of airborne
radioactive particulates
List of all positive whole body count (WBC), in vitro, or air sampling analyses since October
1, 2009, which resulted in an assigned CEDE equal to or exceeding 10 millirem [Note, a
listing should be provided for use by the inspectors to select a sample of issues for in-
depth review during the on-site inspection]
List of all personnel contamination events, dispersed contamination/discrete particles,
identified since October 1, 2009. [Note: only a listing should be provided for use by the
inspectors to select a sample of issues for in- depth review during the onsite inspection]
Copies of all audits, self-assessments, and/or reviews related to internal or external
dosimetry issues generated since October 1, 2009. The documents provided should to
include any reviews/evaluations conducted of vendor facilities, e.g., corporate or outside
vendor/ or corporate calibration facilities.
Enclosure
3
Provide a list of CR documents generated since October 1, 2009, for internal or external
dosimetry issues/events. [Note: only titles/summary statement should be provide for use by
the inspectors to select a sample of issues for in-depth review]
OCCUPATIONAL DOSE ASSESSMENT [71124.04]
Provide Procedures/Guidance Documents for:
external dose monitoring, i.e., dosimetry issuance and use. The documents should
include: guidance for multi-badging; monitoring in steep/highly variable dose rate
gradients; personnel contamination events; storage/care of personal dosimeters; use of
electronic dosimeters including evaluation of any biases identified relative to TLD
monitoring
internal dose assessment, i.e., both in vivo and in vitro bioassay and air sampling
capabilities. The documents should include guidance for calibration/QC and use of whole
body counter (WBC); release of contaminated individuals, use of passive monitoring as
screening method for evaluations, and special in vitro sample collection and analysis,
and actions for declared pregnant workers.
NVLAP accreditation documentation for current dosimetry used by site
List of all positive whole body count (WBC), in vitro, or air sampling analyses which resulted
in an assigned CEDE equal to or exceeding 10 millirem since October 1, 2009. [Note: only
a listing should be provided for use by the inspectors to select a sample of issues for in-
depth review during the onsite inspection]
List of all personnel contamination events, dispersed contamination/discrete particles,
identified since October 1, 2009. [Note: only a listing should be provided for use by the
inspectors to select a sample of issues for in- depth review during the onsite inspection]
List of declared pregnant workers [Note: do not provide this data - the documents will be
reviewed on-site, only have the data readily available during the onsite inspection]
Copies of all audits, self-assessments, and/or reviews related to internal or external
dosimetry issues generated since October 1, 2009. The documents provided should to
include any reviews/evaluations conducted of vendor facilities, e.g., corporate or outside
vendor/ or corporate calibration facilities.
Provide a list of Condition Report (CR) documents generated since October 1, 2009, for
Internal or external dosimetry issues/events. [Note: only titles/summary statement
should be provide for use by the inspectors to select a sample of issues for in-depth review]
RADIOACTIVE GASEOUS AND LIQUID TREATMENT [IP 71124.06]
Provide site and/or corporate procedures associated with implementing the effluents and
the groundwater monitoring program. Procedures should include those that address:
Effluent sampling
Effluent monitor set-point determinations
Dose calculations
Groundwater monitoring and reporting of spills/leaks
Methodology for determining effluent stack/vent flow rates
ARERRs for CYs 2008 and 2009. [Note: provided as part of the General Information
Request and do not need to be duplicated
List of all unmonitored spills, leaks, or unexpected liquid/gaseous discharges since
October 1, 2008. If applicable, provide the LER, event report, and/or special report.
List of non-radioactive systems that have become contaminated and any 10 CFR 50.59
evaluations performed. [Data since October 1, 2008]
List of any changes to the effluent release points or effluent treatment systems and
Enclosure
4
associated 50.59 documentation. [Data since October 1, 2008]
Material condition surveillance records for effluent system components not readily
accessible, including those inaccessible due to radiological conditions
Effluent release permits for continuous gaseous, batch gaseous, continuous liquid, and/or
batch liquid releases. Only provide permits for last releases for September 2010 within each
category.
Results of inter-laboratory comparison program for count lab for CY 2009 to 2010 YTD
The last two surveillance results for ESF ventilation systems (e.g. system flow, HEPA, and
charcoal filter tests)
Groundwater monitoring results since October 1, 2008.
List of changes to written ground water monitoring program for identifying/controlling
contaminated spills/leaks since October 1, 2008.
List of onsite surface water bodies (e.g. ponds, retention basins, lakes) that contain or
potentially contain radioactivity
List of CAP condition report (CR) and audit documents generated since October 2009
related to liquid and gaseous effluent treatment and monitoring, unmonitored spills, leaks,
or effluent discharges, or the groundwater monitoring program.
RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM [IP 71124.07]
Site and corporate procedures associated with radiological environmental monitoring,
including:
Collection, preparation, and analysis of environmental samples including air samples,
TLD stations, ground and surface water, sediment, vegetation, milk, fish, etc.
Calibration and maintenance of air/water sampling equipment
Calibration and QC activities for sample counting instruments
Sampling and monitoring program to detect leaks from contaminated or potentially
contaminated systems, structures, or components
Meteorological instrument calibration, operation, and routine surveillances
AREOR CYs 2008 and 2009. [Note: provided as part of the General Information Request
and do not need to be duplicated].
List of structures, systems, or components that contain or could contain licensed material for
which there is a credible mechanism for the radioactive material to reach ground water
Summary of leaks and/or spills since October 1, 2008, i.e. additions to the 50.75(g) file
Calibration and maintenance records for REMP air and composite water samplers since
October 1, 2008.
Inter-laboratory comparison program results for the past two years (in-house or vendor
laboratory).
Last two calibration /surveillance/maintenance records for the meteorological monitoring
instruments since October 1, 2008.
List of CAP CR and audit documents generated since October 1, 2008, related to
environmental monitoring activities.
RADIOACTIVE SOLID WASTE PROCESSING AND RADIOACTIVE MATERIAL HANDLING
STORAGE AND TRANSPORTATION [IP 71124.08]
Provide Copy of Current Process Control Program (PCP)
Radioactive waste (Radwaste) Information Input into the ARERRs for CYs 08 & 09
Procedures/Guidance/Data Related to:
o transportation of radioactive material/radwaste
o radwaste processing analysis, resin sluicing, and HIC dewatering
Enclosure
5
o Part 61 Sampling and Analysis
o Development/Evaluation of Scaling Factors and Application to Hard to Detect
Radionuclides
o Procedures for evaluation of Reactor Coolant System (RCS)/radioactive waste chemistry
to verify stability of waste stream radionuclide composition
Provide the following:
o List of shipments made since October 1, 2009. Highlight 5 hottest shipments and any
Type A Shipments made since October 1, 2009, using Type A containers
o List of changes made to solid radwaste processing systems since October 1, 2009
o List all permanently abandoned radwaste processing equipment or systems
o The two most recent 10 CFR Part 61 analyses for each waste stream. Note: only need
to provide appropriate onsite contact or location where Part 61 waste stream analysis
data are maintained
o Any data on indication of failed-fuel since October 1, 2009
o List of CAP CR and audit documents related to shipping or radwaste since October 1,
2009. Note: only provide titles/ summaries
o Any self-assessments/audits of shipping/radwaste processing program since 2009
Transport Cask CoCs and associated documents for frequently used transport casks
o Note: Copies not required prior to onsite inspection but listing of responsible staff/on-
site document location and availability requested
Licensee procedures for cask loading and/or closure
PERFORMANCE INDICTOR VERIFICATION [71151]
Procedure/Guidance for collection and reporting of PI data.
Provide the following records:
CRs related to occupational and public radiation safety PI occurrences issued since
October 1, 2009
Monthly/Quarterly Occupation and Public Radiation Safety PI reports since October 1,
2009
List of Out of Service (OOS) Effluent Monitors and Length of Inoperability since October 1,
2009. [Note these data are part of the data requested under Inspection Procedure
7112405 above and do not have to be duplicated]
Procedure for issuing CRs and assessing issues for significance and action.
Updated Final Safety Analysis Report Chapters 11 (Effluents/Radwaste) and 12 (Radiation
Protection)
VERIFICATION OF LICENSEE RESPONSES TO NRC REQUIREMENT FOR INVENTORIES
OF MATERIALS TRACKED IN THE NATIONAL SOURCE TRACKING SYSTEM PURSUANT
TO TITLE 10, CODE OF FEDERAL REGULATIONS, PART 20.2207 (10 CFR 20.2207) [TI
2515/179]
Provide inventory NSTS records of nationally tracked sources, including radionuclide
quantities, make, model number and serial number for each
Provide records of leak tests and required maintenance, as applicable, for the NSTS listed
devices. Records should go back to January 1, 2008, or receipt of subject source(s).
Provide records of any transfer of NSTS devices.
Enclosure