Submittal of Part 21 Final Report: Non-conservative SLMCPR
ML042800267
Person / Time
Site: Hatch, Monticello, Dresden, Peach Bottom, Browns Ferry, Nine Mile Point, Perry, Fermi, Oyster Creek, Hope Creek, Cooper, Pilgrim, Brunswick, Limerick, Vermont Yankee, Duane Arnold, Clinton, Quad Cities, FitzPatrick, LaSalle
(DPR-016, DPR-019, DPR-022, DPR-025, DPR-029, DPR-030, DPR-035, DPR-044, DPR-046, DPR-049, DPR-056, DPR-057, DPR-059, DPR-062, DPR-063, DPR-071, NPF-005, NPF-011, NPF-018, NPF-037, NPF-039, NPF-043, NPF-057, NPF-058, NPF-062, NPF-066, NPF-069, NPF-085)
Issue date: 09/29/2004
From: Post J
General Electric Co
To:
Document Control Desk, NRC/NSIR/PMDA
References
MFN 04-108
Download: ML042800267 (3)


Text

vr GENuclearEnergy General Electric Company 3901 Castle Hayne Road. Wilmington, NC 28401 September 29, 2004 MFN 04-108 U.S. Nuclear Regulatory Commission Document Control Desk Rockville, Maryland 20852-2738 Attention:

Chief, Information Management Branch Program Management Policy Development and Analysis Staff

Subject:

Part 21 Final Report: Non-conservative SLMCPR

Reference:

GENE letter, "Part 21 Reportable Condition and 60-Day Interim Report Notification: Non-conservative SLMCPR," MFN 04-081, August 24, 2004 Global Nuclear Fuel (GNF) and GE Nuclear Energy (GENE) previously notified the NRC in the reference letter that the current GNF process for determination of the Safety Limit Minimum Critical Power Ratio (SLMCPR) can result in a non-conservative SLMCPR. A preliminary screening calculation had been completed to identify the plants that were potentially affected. The evaluation was completed for the plants that had been determined to be potentially affected and these plants were identified as a reportable condition under IOCFR21.21(d) in MFN 04-081. The evaluation was not completed for the plants that had been determined to be potentially unaffected and these plants were identified as a 60-Day Interim Report notification under IOCFR21.21(a)(2) in MFN 04-081.

The evaluation for the potentially unaffected plants has now been completed. The results of the screening calculation have been confirmed: this is not a reportable condition for the plants that were previously identified as a 60-Day Interim Report notification in MFN 04-081.

GENE has historically used a non-conservative SLMCPR impact of 0.01 as the threshold for reportability under IOCFR21. The identified non-conservative SLMCPR change only slightly exceeded the threshold for a Reportable Condition and would not lead to a substantial safety hazard due to the large margin to fuel failure associated with the SLMCPR and the multiple automatic and passive protection features of a BWR.

The plants for which GNF calculates the SLMCPR are identified in Attachment 1. Those plants for which the current SLMCPR is conservative are identified as Not Reportable.

September 29, 2004 MFN 04-108 The plants for which the current SLMCPR is non-conservative by 0.01 or greater were previously identified as a Reportable Condition under IOCFR21.2I(d) in MFN 04-081.

Discussion During performance of SLMCPR calculations for an extended operating domain condition, GNF discovered an apparent flow impact where a lower flow condition at rated power had a more limiting SLMCPR than the rated flow condition.

Current procedures specify that the SLMCPR be calculated on the upper boundary of the power/flow operating map only at 100% power/I 00% flow (rated P/rated F).

The SLMCPR is calculated at 3 operating points in the cycle: (1) Beginning of Cycle (BOC),

(2) Peak Hot Excess (PHE), and (3) End of Cycle (EOC) at rated P/rated F conditions.

The SLMCPR calculation is dependent upon many fuel and cycle parameters and the most limiting SLMCPR may occur at any of the analyzed points. The SLMCPR is the most limiting bundle MCPR from these calculations that corresponds to 0.1 % of fuel rods in the core being susceptible to boiling transition due to the postulated occurrence of the limiting Abnormal Operating Occurrence (AOO) event.

In the instances where this concern was discovered, the control rod patterns used at the off-rated flow/rated power condition created a more limiting bundle-by-bundle MCPR distribution than the control rod patterns used at rated power/rated flow, even though both control rod patterns met the criterion defined in the SLMCPR calculation process, and it produced a more limiting SLMCPR.

GENE/GNF previously notified the affected plants as identified in MFN 04-081, August 24, 2004.

There are no actions necessary for the plants that are confirmed to be unaffected as identified in Attachment 1.

If you have any questions, please call me at (910) 675-6608.

Sincerely, Jason. S. Post, Manager Engineering Quality & Safety Evaluations cc: S. D. Alexander (NRC-NRR/DIPM/IPSB) Mail Stop 6 F2 M. B. Fields (NRC-NRR/DLPM/LPD4) Mail Stop 7 El C. V. Hodge (NRC-NRR/DIPM/IROB) Mail Stop 12 H2 J. F. Klapproth (GENE)

H. J. Neems (GENE)

L. M. Quintana (GENE)

T. Rumsey (GENE)

PRC File 2

September 29, 2004 MFN 04-108 Attachment I - Plants Previously Identified in MFN04-081 Not Reportable Utility Reportable Condition (per MFN04-081)

Plant X

X X

X X

x(2)

X X

X X

X X

X X

X X

X X

X X

2 x

X X

X X

Noes X

X X(2 )

x AmnerGen Energy Co.

AmerGen Energy Co.

Carolina Power & Light Co.

Carolina Power & Light Co.

Constellation Nuclear Constellation Nuclear.

Detroit Edison Co.

Dominion Generation Energy Northwest Entergy Nuclear Northeast Entergy Nuclear Northeast Entergy Operations, Inc.

Entergy Operations, Inc.

Entergy Nuclear Northeast Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

Exelon Generation Co.

FirstEnergy Nuclear Operating Co.

Nebraska Public Power District Nuclear Management Co.

Nuclear Management Co.

Pooled Equipment Inventory Co.

PPL Susquehanna LLC.

PPL Susquehanna LLC PSEG Nuclear Southern Nuclear Operating Co.

Southern Nuclear Operating Co.

Tennessee Valley Authority Tennessee Valley Authority Tennessee Valley Authority Clinton Oyster Creek Brunswick I Brunswick 2 Nine Mile Point I Nine Mile Point 2 Fermi 2 Millstone I()'

Columbia FitzPatrick Pilgrim Grand Gulf River Bend Vermont Yankee CRIT Facility Dresden 2 Dresden 3 LaSalle I LaSalle 2 Limerick I Limerick 2 Peach Bottom 2 Peach Bottom 3 Quad Cities I Quad Cities 2 Perry I Cooper Duane Arnold Monticello PIM Susquehanna I Susquehanna 2 Hope Creek Hatch I Hatch 2 Browns Ferry I (

Browns Ferry 2 Browns Ferry 3

1. Plant is in an extended shutdown
2. Not reportable for current operation, Reportable Condition for SLMCPR licensing submittal 3