ML100070073

From kanterella
Jump to navigation Jump to search

USNRC 10CFR Part 21 Notification - Flowserve Figure 848 Disk/Disk Nut Separation
ML100070073
Person / Time
Site: Beaver Valley, Millstone, Hatch, Monticello, Calvert Cliffs, Davis Besse, Nine Mile Point, Palisades, Palo Verde, Perry, Indian Point, Fermi, Kewaunee, Catawba, Harris, Wolf Creek, Point Beach, Oyster Creek, Cooper, Pilgrim, Susquehanna, Prairie Island, Columbia, Seabrook, Brunswick, Vermont Yankee, Crystal River, Haddam Neck, Ginna, Diablo Canyon, Vogtle, Duane Arnold, Farley, Robinson, Clinton, South Texas, San Onofre, Cook, Comanche Peak, Yankee Rowe, Big Rock Point, Fort Calhoun, FitzPatrick, Waltz Mill, Washington Public Power Supply System  DTE Energy icon.png
Issue date: 11/19/2009
From: Sherman R
Flowserve Corp
To:
AmerenUE, Constellation Energy Group, Detroit Edison, Dominion Energy Kewaunee, Dominion Nuclear Connecticut, Dominion Resources Services, Duke Energy Carolinas, Energy Northwest, FitzPatrick, Entergy Nuclear Generation Co, Entergy Nuclear Operations, Entergy Nuclear Vermont Yankee, Entergy Operations, Exelon Corp, FirstEnergy Corp, Florida Power & Light Co, Indiana Michigan Power Co, Luminant Generation Co, Nebraska Public Power District (NPPD), NextEra Energy Seabrook, Division of Inspection and Regional Support, Omaha Public Power District, Pacific Gas & Electric Co, Susquehanna, Progress Energy Carolinas, Public Service Enterprise Group, South Texas, Southern Nuclear Operating Co, Tennessee Valley Authority, Union Electric Co, Wolf Creek, Xcel Energy
Dave Garmon -415-3512
References
FOIA/PA-2011-0115
Download: ML100070073 (8)


Text

...,

FLOWSERVE November 19, 2009

Subject:

USNRC 10CFR Part 21 Notification

Reference:

Flowserve Figure 848 Disk/Disk Nut Separation

Attachment:

USNRC Notice 11 0609

Dear U.S. Nuclear Utility customers:

Flow Control Division Anchor/Oarlillg Valves BW/IP Valves Edward Valves VaJlek Conlrol Producls Worcester Valves Please find the attached USNRC Notice 11 0609 that has been filed with US Nuclear Regulatory Commission in accordance with the provisions of 10CFR-Part 21.

The subject valves are Flowserve Figure 848 (threaded ends) or 848Y (socket weld ends) V-pattern bolted bonnet stop valves. The disk nut of the valve in the attached notice separated from the disk. In this case the safety function of the valve was not affected by the separation of the disk nut from the disk.

However, other Figure 848 or 848Y valves may have different safety related functions that could be affected by this type of failure.

These valves would have been manufactured and shipped from our Sulphur Springs, Texas facility until 1987, when it was then transferred to our Raleigh, North Carolina facility. The old design valves were then manufactured at our Raleigh facility from 1987 through late 1992, when the current Figure A848 or A848Y design transition was finalized. These valves may have manufacturer's nameplates identified with "Rockwell", "Rockwell Edward" or "Edward".

The current design Flowserve Figure A848 or A848Y valves manufactured in Raleigh, NC are not affected by this notice as the disk nut was eliminated and the disk is now secured to the stem using a Stellite retaining wire configuration.

In summary there is no impact if the valve nameplate indicates a model that includes an "A" prefix (6848 or 6848Y) signifying the current design configuration.

Due to the volume, age and relocation of this product, we can not identify the specific utilities that may potentially be affected, as such we are providing this general notice for information to all utilities. Per the attached notice we would encourage that any of the old design Figure 848 or 848Y valves be inspected for proper operation for safety related concerns. Should you find it necessary, replacement parts are available for a simple retrofit without removing the valve body from the installed application.

If you have any questions concerning this notification, please contact our customer service in Raleigh, NC at 800-225-6989 or your Flowserve Area Sales Manager.

~~~~~~

Manager, Inside Sales & Application Engineering Flowserve U S Inc Flow Control Division Raleigh Operations PO Box 1961 1900 South Saunders Street Raleigh, NC 27603 Toll Free:

1-800-225-6989 Phone:

1-919-832-0525 Facsimile: 1-919-831-3369 W\\'N/.ftowserve.com

10CFR Part 21 - Nuclear Utility Contacts Exelon Corporation 4300 Winfield Road Warrenville, IL 60555 Attn: Ted Thygesen NextEra Energy Seabrook, LLC Seabrook Station P.O. Box 300 Seabrook, NH 03874 Attn: Richard Swain The Detroit Edison Company Enrico Fermi Power Plant 2 6400 North Dixie Hwy Newport, MI 48166 Attn: Pamela Key Dominion Nuclear Ct., Inc.

Dominion Rope Ferry Road Waterford, CT 06385 Attn: Kim Swaney PSEG Nuclear LLC P.O. Box 236 Hancocks Bridge, NJ 08038 Attn: Frank Smith Indiana Michigan Power Company Donald C. Cook Nuclear Plant 9970 Red Arrow Highway Bridgman, MI 49106 Attn: John Moline First Energy Perry Nuclear Power Plant 10 Center Road Perry, OH 44081 Attn: Pam Ensell Davis Besse Nuclear Power Plant 5501 N. State Route 2 Oak Harbor, OH 43449 Attn: Darlene Paul

First Energy Beaver Valley Power Station Route 168 Shippingport, PA 15077 Attn: Betsy Schoeneman Eileen Rizzo PPL Susquehanna LLC 769 Salem Boulevard Berwick, PA 18603-0467 Attn: Clem Perluke Constellation Energy Group (CEG)

Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, MD 20657-4702 Attn: William M. Hill Wayne Carroll Constellation Energy Group (CEG)

Nine Mile Point Nuclear Station 348 Lake Road Oswego, NY 13126 Attn: Michael Flood Holly Beall Constellation Energy Group (CEG)

R,E. Ginna Nuclear Power Plant 1503 Lake Road Ontario, NY 14519 Attn: James Martin Joseph Prytyskach Entergy Nuclear Vermont Yankee, LLC 320 Governor Hunt Road Vernon, VT 05354 Attn: Patty Thayer Entergy Nuclear Fitzpatrick, LLC 277 Lake Road Oswego, NY 13126 Attn: Pat Larson Entergy Nuclear Operations, Inc.

Indian Point Energy Center 450 Broadway Buchanan, NY 10511 Attn: Ken Bailey Michael Cook

Entergy Nuclear Generation Co.

Pilgrim Nuclear Power Station 600 Rocky Hill Road Plymouth, MA 02360 Attn: Deborah Martin Palisades Nuclear Power Plant 27780 Blue Star Memorial Covert, MI 49043 Attn: John Kasishke George Kelly FPL Nuclear Assurance Department, JNA/JB 700 Universe Blvd Juno Beach, FL 33408 Attn: Manager Performance Assessment Duke Energy Carolinas, LLC Nuclear Performance & Strategy Division Mail Code EC05N PO Box 1006 Charlotte, NC 28201-1006 Attn: Manager Performance Improvement Dominion Resources Services, Inc.

Innsbrook Technical Center 5000 Dominion Blvd Glen Allen, VA 23060 Attn: Director, Nuclear Licensing & Operations Support Entergy Operations, Inc.

M-ECH-595 P. O. Box 31995 Jackson, MS 39286-1995 Attn: Manager, Operating Experience Southern Nuclear Operating Company P. O. Box 1295 Birmingham, AL 352021 Attn: Licensing Manager

Southern Nuclear Operating Company Hatch Electric Generating Plant 11028 Hatch Parkway North Baxley, GA 31513 Attn: Plant Supply Chain Superintendent Vogtle Electric Generating Plant 7821 River Road Waynesboro, GA 30830 Attn: Plant Supply Chain Superintendent Southern Nuclear Operating Company Farley Nuclear Plant P. O. Drawer 470 Ashford, AL 36212 Attn: Plant Supply Chain Superintendent TVA 1101 Market Street Chatonooga, TN 37402 Attn: Mr. Ron J. Bruno - Licensing Office Progress Energy Harris Nuclear Plant State Road 1134, Box 165 New Hill, NC 27562 Attn: Site Vice President Progress Energy Harris Nuclear Plant State Road 1134, Box 165 New Hill, NC 27562 Attn: Site Supv-Lic/Reg Prog Progress Energy Brunswick Nuclear Plant NC Hwy 87, Box 10429 Southport, NC 28461 Attn: Site Vice President

Progress Energy Brunswick Nuclear Plant NC Hwy 87, Box 10429 Southport, NC 28461 Attn: Site Supv-Lic/Reg Prog Progress Energy Robinson Nuclear Plant SC Hwy. 151 & 23, Box 790 Hartsville, SC 29550 Attn: Site Vice President Progress Energy Robinson Nuclear Plant SC Hwy. 151 & 23, Box 790 Hartsville, SC 29550 Attn: Site Supv-Lic/Reg Prog Progress Energy Crystal River 3 Nuclear Plant 15760 W Power Line St.

Crystal River, FL 34428 Attn: Site Vice President Progress Energy Crystal River 3 Nuclear Plant 15760 W Power Line St.

Crystal River, FL 34428 Attn: Site Supv-Lic/Reg Prog APS Palo Verde 5801 South Wintersburg Road Tonopah, AZ 85354 Attn: Phillip Smyth Edison SONGS 14300 Mesa Road San Clemente, CA 92672 Attn: Cheryl Downe

Energy Northwest Columbia Generating Station Snake River Warehouse Complex 76 North Power Plan Loop Richland, WA 99354 Attn: Michael J. Woodruff Pacific Gas Electric company Diablo Canyon Power Plant 9 Mi. Northwest of Avila Beach Avila Beach, CA 93424 Attn: Thomas J. Head FPL - Point Beach 6610 nuclear Road Two Rivers, WI 54241-9516 Attn: Denise Schmidt FPL - Duane Arnold 3277 DAEC Road Palo, IA 52324 Attn: Pat Phipps Dominion Energy Kewaunee N490 Highway 42 Kewaunee, WI 54216 Attn: Carol Torgersen Xcel Energy-Monicello 2807 West County Road 75 Monticello, MN 55362-9637 Attn: Vicki Bestgen Xcel Energy-Praire Island 1717 Wakonade Drive, East Welch, MN 55089-9642 Attn: Rhonda J. Beck

Luminant Generation Co LLc Comanche Peak 6322 North FM 56 Glen Rose, TX 76043 Attn: Michael Ware Omaha Public Power District Fort Calhoun Station FC 1-5 PO Box 550 Fort Calhoun, NE 68023 Attn: Jay Costello Union Electric Company Accounts Payable d/b/a Ameren UE PO Box 66892 St. Louis, MO 63166-6892 Attn: Lewis (Will) Armstrong NPPD Cooper Nuclear Station 72676 648A Avenue Brownville, NE 68321 Attn: Kim Perry South Texas Project Nuclear Operating Company PO Box 289 8 Mi. West of Wadsworht on FM 521 Wadsworth, TX 77483 Attn: Madelyn M. Ressman Wolf Creek Nuclear Operating Company PO Box 411 1550 Oxen Lane, NE Burlington, NS 66839 Attn: Betty Sayler