Part 21 Report - Crane Nuclear Pressure Seal Valve with Retaining Rings
ML15223B266
Person / Time
Site: Hatch, Browns Ferry, San Onofre  
Issue date: 08/07/2015
From: Klein J
Crane Nuclear
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
51296
Download: ML15223B266 (5)


Text

08/07/2015 U.S. Nuclear Regulatory Commission Overations Center Event Renort Pfi*rp 7 Part 21 (PAR)

Event #

51296 Rep Org: CRANE NUCLEAR, INC Notification Date I Time: 08/06/2015 20:00 (EDT)

Supplier: CRANE NUCLEAR, INC Event Date / Time: 02/20/2015 (CDT)

Last Modification: 08/06/2015 Region:

3 Docket #:

City:

BOLINGBROOK Agreement State:

Yes County:

License #:

State:

IL NRC Notified by: JASON KLEIN Notifications: ANTHONY MASTERS R200 HQ Ops Officer: JEFF ROTTON RAY AZUA R4DO Emergency Class: NON EMERGENCY PART 21/50.55 REACTORS EMAIL 10 CFR Section:

21.21 (d)(3)(i)

DEFECTS AND NONCOMPLIANCE PART 21 - CRANE NUCLEAR PRESSURE SEAL VALVE WITH RETAINING RINGS The following summary was excerpted from a facsimile received from Crane Nuclear:

"This letter provides interim notification of Crane Nuclear's investigation into ASME Boiler and Pressure Vessel Section III Code design Pressure Seal Valve orders for yokes with integral hubs acting as retaining rings.

"The information required for this notification is provided below:

"Name and address of the individual or individuals informing the Commission: Jason Klein, Sustaining Engineering Manager and Rosalie Nava, Director Safety and Quality, Crane Nuclear, 860 Remington Blvd.,

Bolingbrook, IL 60440 "Identification of the basic component supplied for such facility or such activity within the United States which may fail to comply or contains a potential defect: Pressure Seal Valve orders may potentially have misclassified material and non-destructive examination requirements for Yokes with integral hub retaining ring designs.

"Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply: Crane Nuclear 'Classification of Valve Parts', Procedure 03-107, provides guidance for appropriate material and NDE requirements for processing valve and valve part orders. The procedure is based on the ASME Code Case N-62, which is ASME B&PV Section III, 2015 Edition, Non-Mandatory Appendix HH

'Rules for Valve Internal and External Items'. A yoke incorporating a threaded hub should be treated in the same manner as a threaded retaining ring requiring the material to be purchased Safety Related, ASME B&PV Section II, Part D materials, and required NDE (reference Category 3 valve items per N-62). However, yokes with integral hubs acting as retaining rings may have been processed to material requirements for a yoke per Procedure 03-

08/07/2015 U.S. Nuclear Regulatory Commission Operations Center Event Report Page 2 107 and not a threaded retaining ring resulting in the incorrect material specification and non-destructive examination specified.

"Crane Nuclear has completed the sales orders search of the ASME Section III Code Pressure Seal Valve designs with retaining rings from 1992 to present. We identified a total of 112 orders that required review. Of these orders, three orders were supplied with non-compliant retaining ring material for the valve assemblies. The three orders are as follows:

"CNI SO# 24237-011, TVA, Browns Ferry, P.O. 00031943 - Quantity shipped = 1, Chapman, 8 inch, Figure L953, Class 900, ASME Class 2, 95 Ed., 96 Add., no N stamp "CNI SO# 39501-01, Georgia Power, Hatch, P.O. SNG10016537 - Quantity shipped = 3, Crane,. 3 inch, Figure 776U, Class 600, ASME Class 3, 71 Ed., W71 Add.

"CNI SO# 39745-01, Southern California Edison, San Onofre, P.O. 4500456451 - Quantity shipped = 1, Aloyco, 4 inch, Figure N5247PSB, Class 900, ASME Class 3, 71 Ed., S73 Add.

"Crane Nuclear is currently investigating sales orders from 1968 to 1992. We require an additional 30-60 days to complete our review.

"Corrective action being taken by Crane Nuclear is to review documentation of the supplied material on the affected orders to determine if the yokes can be recertified as currently supplied, amend Crane Nuclear Procedure 03-1 07 to add figures reflecting configurations and clarify classifications, and train Engineering personnel by August 24, 2015.

"Crane Nuclear has notified the respective customers for the [three] orders that have been identified to date.

Crane will notify the respective customers for any additional orders that are identified.

"Should you have any questions regarding this matter, please contact Jason Klein, Sustaining Engineering Manager at (630) 226-4953 or Rosalie Nava, Director of Safety and Quality at (630) 226-4940."

TEIEFI0NE (630) 226=4900 I""*

  • N...

' '* ' 'I "FA

  • X (630)226 -4646

~~WWw,(crpnen1ticlear, om]*

NUCLEAR CRANE NUCLEAR., iNC, 860 R*EMINGTON BOULEVARD BOLINGBRQOK, IL. 60440 Date:

Augiast 6,20X5 Attn: Document Control Desk U.S. NUclear Regulatory Commission.*.

Washington, D.C. 20555-001 Subject t.0 CFR Part 21 Investigation Report Notification of Pressure Seal Valve Yoke Material Compliance

Dear Sir or Madam:

This letter provides interim notification of Crane Nuclear's investigation into ASME Boiler and Pressure Vessel Section III Code design Pressure Seal Valve orders for yokes with integral hubs acting as retaining rings. The information required for this notification is provided below:

(i) Name and address of the individual or individuals informing the Comm ission.

Jason KI~in Sustaining Engineering Manager Rosalie Nava Director Safety and Quality Crane Nuclear 860 Remington Blvd Rolingbrook, IL 60440 (ii) Identification of the basic component supplied for such facility or such activity within the S:i..*. United States which may fail to comply or contains a potential defect

,i -.

Pressure Seal Valve orders may potentially have misclassified material and non-destructive examination requirements for Yokes with integral hub retaining ring designs.'

(JOi Identification of the firm supplying the basic component which falls to comply or contains a defect..

Crane Nuclear 860 Remington Blvd Bolingbrook, IL 60440 (iv) Nature of the defect or failure to comply and the safety hazard which is created or could be created by such defect or failure to comply.

Page 1 of S

MUU.I b ZU.

2 O:bUh*VI

[U, 512 V. 2 TELEPHONE (0ivj 220-4900

~tft~ kj NUTCLEARw~tneul~o CRANE NUCLEAR, INC.

860 REMINGTON BOULEVARD BOLINGBROOIK IL. 60440 Crane Nuclear "Classification of Valve.Parts", Procedure 03-1]07, provides guidance for appropriate material and NDE requirements for processing valve and valve part orders. The procedure is based on the ASME Code Case N-62, which is ASME B&PV Section III, 201.5 Edition, Non-Mandatory Appendix H H "Rules for Valve Internal and External Items".

A yoke incorporating a threaded hub should be treated in the same manner as a threaded retaining ringtequiring the material to be purchased Safety Related, ASM E B&PV Section II, Part 0 materials, and required NDE (reference Category 3 valve items per N-62). However, yokes with integral hubs acting as retaining rings may have been processed to material requirements for a yoke per Procedure 03-107 and not a threaded retaining ring resulting in the incorrect material specification and non-destructive examination specified.

(',) The dote on which the information of such defect or failure to comply was obtained.

Crane Nuclear Engineering initiated investigation correspondence to Crane Nuclear Director of Safety and Quality via email correspondence dated Feb 2ot 201!5.

(vii) In the case of a basic component which contains a defect or falls to comply, the number and (ocation of these components in use at, supplle'd for, being supplied for, or may be supplied for, manufactured, or being manufactured for one or more facilities or activities subject to the regulations in this part.

Crane Nuclear has completed the sales orders search of the ASME Section III Code Pressure Seal Valve designs with retaining rings from 1.992 to present. We identified a total of :112 orders that required review. Of these orders, three orders were supplied with non-compliant retaining ring material for the valve assemblies. The three orders are as follows:

1.

CNI SQ# 24237-01, TVA, Browns Ferry, P.O. 00031943 - Qua-ntity shipped = 1, Chapman, 8", Figure L953, Class 900, ASME* Class 2, 95 Ed., 96 Add., no N stamp

2. CNI SO#l 39501I-0:1, Georgia Power, Hatch, P.O.. SNG10016537 - Quantity shipped 3,

Crane, 3"', Figure 776U, Class 600, ASMEiiClass 3, 7: Ed., W7:1 Add.

3. CNI SO#l 39745-01, Southern California Edison, San Onofre, P.O. 4500456451%) - Quantity shipped --1, Aloyco, 4", Figure N5247P5B, Class 900, ASME Class 3, 71 Ed., 573 Add.

Crane Nuclear is currently investigating sales orders from 1968 to 1992. We require an additional 30-60 days to complete our review.

(vii) The corrective action which has been, is being, or will be taken; the name of the individual or organization responsible for the action; and the length of time that has been or will be taken to complete the action.

Corrective action being taken by Crane Nuclear is to review documentation of the supplied material on the affected orders to determine if the yokes can be recertified as currently supplied, amend Crane Nuclear Procedure 03-107 to add figures reflecting configurations and clarify classifications, and train Engineering personnel by August 24, 2015.

Page 2 off 3

MUU.O 0, 1U15 O*inviV I'Ju, i1/

TEL-FI*ONE (630O) 226A4900

]FAX (630)226-4*64 ww-w~crannulcarIvo1xn

r.

j CRA*NE NUCLEAR, INC NUCLEAR 860 REMINGTON BOULEVARD BOL1NGBROOK, IL. 80440 (viiih Any advice related to the defect or failure to comply about the facility, activity, or basic component that has been, is being, or will be given to purchasers or llcensee&.

Crane Nuclear has notified the respective customers for the four orders that have been identified to date. Crane will notify the respective customers for any additional orders that are identified.

(ix) In t~he case of an early site permit, the entities to whom an early site permit was transferred.

Not applicable.

Should you have any questions regarding this matter, please contact Jason Klein, Sustaining Engineering Manager at (630) 226-4953 or Rosalie Nava, Director of Safety and Qua lity/at (630) 226-4940.

Klein Page 3 of 3