Text
Aug. 23, 2002 7
Page 1 of I MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2002-39474 USER INFORMATION:
F-LAI41LAURL EMPL#:23244 CA#: 0363 Adddrpcc- TJTTCSA2 Phone#: 254-3658 TRANSMITTAL INFORMATION:
To: FLAII1+LAUfEL P 08/23/2002 LOCATION: DOCUMENT CONTROL DESK FROM: NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
,__,/THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:
100 - 100 - EMERGENCY DIRECTOR/CONTROL ROOM:
EMERGENCY PLAN-POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE: 08/08/2002 ADD MANUAL TABLE OF CONTENTS DATE: 08/22/2002 CATEGORY: PROCEDURES TYPE: EP ID: EP-PS-100 REMOVE: REV:15 ADD: REV: 16 REMOVE: PCAF 2002-1436 REV: N/A UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES. PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
PROCEDURE COVER SHEET PPL SUSQUEHANNA, LLC NUCLEAR DEPARTMENT PROCEDURE EMERGENCY DIRECTOR, CONTROL ROOM: EP-PS-100 Emergency-Plan-Position Specific Instruction Revision 16 Page 1 of 4 QUALITY CLASSIFICATION: APPROVAL CLASSIFICATION:
( ) QA Program (X) Non-QA Program ( ) Plant 1/ /.,( ) Non-Plant (X) ,lnstruction',',"
EFFECTIVE DATE,, _______________
PERIODIC REVIEW FREQUENCY:%* Two Years PERIODIC REVIEW DUE'DATE: _-___"____
RECOMMENDED REVIEWS:, .
All Procedure Owner Nuclear Emergency Planning Responsible Supervisor: Manager-Nuclear Operations Responsible FUM: Supv.-Nuclear Emergency Planning Responsible Approver: V.P.-Nuclear Operations FORM NDAP-QA-0002-1, Rev. 3, Page 1 of 1
EP-PS-1 00 Revision 16 Page 2 of 4 EMERGENCY DIRECTOR (ED) - CONTROL ROOM: Emergency Plan-Position Specific Procedure WHEN: Anytime an abnormal event is occurring HOW NOTIFIED: On shift REPORT TO: Duty Manager WHERE TO REPORT: Control Room OVERALL DUTY:
Take charge of the plant from the Control Room during an emergency condition, assigning duties and directing operations as necessary to return to a safe plant condition (NDAP-QA-300).
MAJOR TASKS: TAB: REVISION:
Classify the emergency as conditions TAB A 8 indicate.
Manage the UNUSUAL EVENT. TAB B 12 Manage the ALERT EMERGENCY. TAB C 10 Manage the SITE AREA EMERGENCY. TAB D 12 Manage the GENERAL EMERGENCY. TAB E 9 Manage the Security Threat or Event TAB G 1 EAL series 16.
EP-PS-1 00 Revision 16 Page 3 of 4 SUPPORTING INFORMATION: TAB:
Emergency Telephone Instructions TAB 1 Emergency Organization TAB 2 Brief Non-Technical Description of EAUs TAB 3 Emergency Classification TAB 4 Public Protective Action Recommendation Guide TAB 5 PPL Emergency Personnel Dose'Assessment and TAB 6 Protective Action Recommendation (PAR) Guide j Personnel Accountability TAB 7 Restoration Organization Guidelines TAB 8 Emergency Forms TAB 9 o Potassium Iodine (KI) Tracking Form o Emergency Notification Report 0o Protective Action Recommendation Form o Protective Action Recommendation State Notification Form
EP-PS-100 Revision 16 Page 4 of 4
REFERENCES:
ICRP Publication 28, The Principles and General Procedures for Handling Emergency and Accidental Exposures of Workers. International Commission on Radiation Protection. (1978)
NCRP Report 39, Basic Radiation Protection Criteria, National Council on Radiation Protection and Measurements. (1971)
NCRP Report 55, Protection of the Thyroid Gland in the Event of Releases of Radioiodine, National Council on Radiation Protection and Measurements. (1977)
SSES Emergency Plan Environmental Protection Agency Manual of Protective Action Guides and Protective Actions for Nuclear Incidents. (1979)
NDAP-QA-1 190, Nuclear Department Radiation Protection Program and Policies NDAP-QA-1191, ALARA Policy and Program IE Notice, 83-28 NUMARC Graded Response Study NUREG-0654, Planning Standards and Evaluation Criteria NUREG-0731, Guidelines for Utility Management Structure and Technical Resources, September 1980 SP-00-308, Emergency Medical Response, Search/Rescue Letter dated February 25, 2002, from Samuel J. Collins, Director, Office of Nuclear Reactor Regulations, to Robert G. Byram, Senior Vice President and Chief Nuclear Officer.
TAB 5 EP-PS-100-5 PAR AIRBORNE RELEASES EP ENTERED MONITOR CONDITIONS:
- PLANT STATUS/PROCEDURES
- ONSITE RAD CONDITIONS CONTINUE
- STATUS OF RELEASE
- DOSE PROJECTIONS PAP PA-1 PA-1 AS GENERI EERGENCY, BEEN NO DELARED?
YES EPROJECTIONS IDOOTINC RECOMMEND TEDOSES O E TO GROUNYES EVACUATION 4 CREM -COMMIED DSE UALT T 0-10 MILES PPA-5 PPA-i NO OR UNKNOWN 1.TER PA CANLBE USDTORERTOSECIN41O RCDR O OEDTIE NOMO NTEATO 0-2 MILES............................' M AND SHELTERING "*.ASSESSMENT 2-10 MILES PA-1 PA-4 NOTES:
- 1. PA-0 CAN BE USED TO REFER TO SECTION 4.1 OF THE PROCEDURE FOR MORE DETAILED INFORMATION ON THE ACT10N TO BE TAKEN.
- 2. DOSE PROJECTIONS DO NOT INCLUDE DOSE ALREADY RECEIVED.
3 TFDE - WHOLE BODY (TED)E) IS THE SUM OF EFFECTIVE DOSE EQUIVALENT RESULTING FROM EXPOSURE TO EXTERNAL SOURCES THE COMMITTED EFFECTIVE DOSE EQUIVALENT (CEDE) FROM ALL SIGNIFICANT INHALATION PAT-HWAYS AND THE DOSE DUE TO GROUND DEPOSITION.
- 4. CDE - COMMITTED DOSE EQUIVALENT TO THE CHILD THYROID.
EP-AD-000-126, Revision 9, Page 1 of 6
TAB 5 EP-PS-1 00-5 PAR LIQUID RELEASES ENTRY:
INDICATIONS OF A POTENTIAL LIQUID RELEASE
- UNISOLABLE RADWASTE TANK RELEASE
- LEAK TO COOLING TOWER BASIN
- LEAK TO SPRAY POND PL-1 Isotopic Umit ENSURE CHEMIESD RADIONUCLIDE (uCdmi) TAKES AND ANALYZES Ag-110m 1.1E"6 SAMPLES As-76 7.2E"7 PL-2 6
Ba-1 40 1.1 E" Ce-1 41 3.6E"6 Co-58 1.1 E-4
> R=EC o NO ACTION CONTINUE Co-60 1.2E-6 REQUIREMENTS (AT REQUIRED MONITORING Cr-51 7.2E,5 Cs-134 2.4E 4 Cs-137 2.4E"6 Fe-55 2.4E 5 Yes Fe-59 2.4E" H-3 2.4E4 RAD PERSONNEL 1-129 1.2E-8 NOTIFY DANVILLE AND 1-131 3.6E-8 BRP THAT A RELEASE La-140 7.2E-7 HAS OCCURRED Mn-54 3.6E,6 PL-4 Mo-99 7.2E-6 Na-22 4.8E"6 CHEMIFTD EVALUATES Nb-95 3.6E6 RELEASE vs PAG Ni-59 3.6E-6 Ni-63 6.0E"7 P-32 3.6E-7 Ru-1 03 2.4E6 Ru-106 3.6E-7 EXCE RAD PERSONNEL Sb-1 24 7.2E-7 ANY OFRELEASE PP-ES THE TABLE LIMITS NOTIFY DANVILLE 3.6E"6 OR DOES THE SUM OF Sb-1 25 'ýFRACTInONS EFXCEEDL1.0 AT -No THAT NO PAR IS Sr-89 2.4E"7 DANVILLE? REQUIRED 8
Sr-90 9.6E- PL-8 Tc-99m 1.1 E,5 7.2E"7 Y-90 T Yes Zn-65 3.6E~e Zr-95 2.4E6 RAD PERSONNEL NOTIFY DEPIBRP FOR DANVILLE TO DIVERT DRINKING WATER SUPPLY & ESTIMATED TIME OF ARRIVAL OF RELEASE AT DANVILLE PL-7 NOTES:
- 1. PL-# CAN BE USED TO REFER TO SECTION 4.2 OF THE PROCEDURE FOR MORE DETAILED INFORMATION ON THE ACTION TO BE TAKEN.
- 2. CALLS TO DANVILLE ARE COURTESY INFORMATION CALLS ONLY. PROTECTIVE ACTION RECOMMENDATION CALLS MUST BE MADE BY DEPIBRP.
EP-AD-OOD-126, Revision 9, Page 2 of 6
TAB 5 EP-PS-1 00-5 PUBLIC PROTECTIVE ACTION RECOMMENDATION GUIDE AIRBORNE RELEASES E- PA-1 MONITOR CONDITIONS FOR PAR APPLICATION The following conditions should be continuously evaluated to determine if a PAR should be implemented or changed:
"* Plant status and prognosis for changes in conditions
"* Onsite radiological conditions
"* Status of actual or potential radioactive releases
"* Offsite dose projections or actual offsite radiological conditions
"* Escalation in Emergency Classification (i.e., General)
(Go to PA-2)
PA-2 HAS A GENERAL EMERGENCY BEEN DECLARED?
E- YES - Ifa GENERAL EMERGENCY has been declared, a PAR must be made within 15 minutes of the emergency declaration. The PAR requirement is found in K>NUREG-0654. (Go to PA-3)
El NO - If a GENERAL EMERGENCY has not been declared, continue to monitor plant status, parameter trends, and prognosis for termination-or escalation of the event. (Go to PA-1)
PA-3 IS THERE A VALID DOSE PROJECTION INDICATING DOSES OF Ž 1 REM TEDE OR>
5 REM CDE CHILD THYROID AT A DISTANCE OF
> 2 MILES?
El YES - Ifthe projected doses at 2 miles are > 1 REM TEDE or 25 REM CDE child thyroid, then full evacuation (0-10 miles) is recommended.
(Go to PA-5)
El NO/UNKNOWN - (Go to PA-4)
EP-AD-000-126, Revision 9, Page 3 of 6
TAB 5 EP-PS-1 00-5 "0 PA-4 RECOMMEND EVACUATION 0-2 MILES; SHELTER 2-10 MILES Limited Evacuation (0-2 miles) and sheltering is appropriate for events that are significant enough to cause a General Emergency classification and dose projections are low, unknown, or below full evacuation guidelines.
"0 PA-5 EVACUATE 0-10 MILES Full evacuation of members of the general public is recommended at this point based on the emergency classification and dose projections.
EP-AD-O00-126, Revision 9, Page 4 of 6
TAB 5 EP-PS-1 00-5 LIQUID "0 PL-1 ENTRY This section is entered when there are indications of a potential radioactive liquid release.
Indications of potential releases include:
"* an unisolable radwaste tank release.
"* leaks to cooling tower basin
"* leak to spray pond (Go to PL-2)
O PL-2 CHEMISTRY/ENVIRONMENTAL SAMPLING DIRECTOR (ESD) TAKES AND ANALYZES SAMPLE (Go to PL-3)
PL-3 IS RELEASE > TECHNICAL REQUIREMENTS LIMITS (AT THE RELEASE POINT)?
o1 YES --Releases are at or greater than Technical Requirements limits when Chemistry determines that the limits are exceeded based on methodologies described in the ODCM and applicable Chemistry procedures.
EO NO - If the release is < Technical Requirements limits, then no notifications are required and monitoring should continue.
(Go to PL-4)
O PL-4 RAD PERSONNEL NOTIFY DANVILLE AND BRP THAT A RELEASE HAS OCCURRED Depending on which facility is activated, the notification to Danville and BRP will be made by the RPC (TSC) or the Radiological Liaison (EOF).
DO NOT MAKE ANY PROTECTIVE ACTIONS RECOMMENDATIONS AT THIS TIME.
EP-AD-000-126, Revision 9, Page 5 of 6
TAB 5 EP-PS-1 00-5 0 PL-5 CHEM/FTD EVALUATES RELEASE VERSUS PAGs The results of the sample analysis are compared to the PAGs for radionuclides in drinking water. The analysis calculates the expected concentration at Danville, taking into account the dilution afforded by the river.
PL-6 DOES RELEASE EXCEED PAGs (AT DANVILLE)?
o YES - Ifa single isotope exceeds the PAG or the sum of the fractions exceeds 1.0, then a protective action recommendation should be made for Danville to DIVERT its DRINKING WATER supply to a backup supply until the release has passed.
(Go to PL-7) o NO - If the PAGs are not exceeded, monitoring should continue and the State should be notified that no PAR for the liquid release is required. (Go to PL-8)
"O PL-7 RAD PERSONNEL NOTIFY DEP/BRP OF PAR Depending on which facility is activated, the PAR notification to DEP/BRP will be made by the RPC (TSC) or the Radiological Liaison (EOF). The PAR FORM shall be used to document the PAR.
DO NOT COMMUNICATE THE PROTECTIVE ACTION RECOMMENDATION TO DANVILLE. THE DEP/BRP IS RESPONSIBLE FOR THIS COMMUNICATION.
"0 PL-8 RAD PERSONNEL NOTIFY DEP/BRP No PAR is required. Depending on which facility is activated, the RPC (TSC) or the Radiological Liaison (EOF) shall notify DEP/BRP that no PAR is required.
EP-AD-000-126, Revision 9, Page 6 of 6
TAB 9 "EP-PS-100-9 PROTECTIVE ACTION RECOMMENDATION STATE NOTIFICATION FORM 0l THIS IS A DRILL D THIS IS NOT A DRILL (This form is to be used to communicate PPL's Protective Action to the senior state official at 717-651-2148.)
- 1. This is of the Susquehanna Steam Electric Station.
(Fill in your name)
- 2. I am the: El Emergency Director at the Susquehanna SES Control Room o Emergency Director at the Technical Support Center O Recovery Manager at the Emergency Operations Facility
- 3. I am about to provide a Protective Action Recommendation. Do I have the Senior State Official on the line?
Name
- 4. A General Emergency has been declared as of
- 5. This declaration was made due to:
- 6. The PPL Susquehanna Protective Action Recommendation is:
ol Evacuate 0-10 miles o1 Evacuate 0-2 miles and shelter 2-10 miles El Divert Danville drinking water supply from the Susquehanna River D Evacuate beyond 10 miles (specify distance .)
- 7. Date/Time:
EP-AD-000-077, Revision 0, Page 1 of I
TAB,9 EP-PS-100-9 Affected Unit Control No.
PROTECTIVE ACTION RECOMMENDATION FORM SUSQUEHANNA STEAM ELECTRIC STATION 0l This is a Drill 0l This is NOT a Drill Preparer:
The EMERGENCY CLASSIFICATION is:
0l Unusual Event 0l Alert 0l Site Area Emergency El General Emergency Basis: EAL #
This represents:
E Initial Classification El Escalation El Reduction El No Change in the Classification Status Emergency Action(s) implemented onsite:
El None 0l Evacuation of non-essential personnel "El Local Area Evacuation 0l KI to onsite personnel "El Site Accountability El Other Bases:
The PROTECTIVE ACTION RECOMMENDATION is:
El No Protective Action Recommendation Required El Evacuate 0-2 miles and Shelter 2-10 miles El Relocation o Evacuate 0-10 miles El Control of Access El Contamination Controls/Decon El Divert Danville Drinking Water* El Other
- Expected arrival of release at Danville:
This represents: El Initial El Change El No Change in the Protective Action Recommendation EP-AD-000-110, Revision 7, Page 1 of 2 (duplex)
TAB%9 EP-PS-1 00-9 The BASIS for the Protective Action Recommendation is:
Plant Status Radioactive Release: 0 Monitored El Unmonitored Status Airborne Liquid
< Tech Requirements Limit (Routine) 10
> Tech Requirements Limit (Event Related) 0 Note: TRM Limits (lCi/min): Noble Gas 8.51 E+5; Iodine 1.04E+2; Particulate 7.72 E+2 (Airborne releases)
Data measured in the field confirm release rate estimations: 0 Yes 0 No Weather Conditions: Wind Speed Wind Direction Dose Projections: 0 TEDE > 1 rem or thyroid CDE > 5 rem at 2 miles o1 TEDE > 1 rem or thyroid CDE > 5 rem at EPB O TEDE *1 rem and thyroid CDE <5 rem at EPB Other:
Approval: Date/Time:
Emergency Director or Recovery Manager approval required if change in Classification or Protective Action Recommendation.
RPC or DASU approval if no change in the Classification or Protective Action Recommendation.
Transmittal: [I Verbal 0 Electronic 0 Both Communicated To:
NAME AGENCY DATE/TIME EP-AD-000-1 10, Revision 7, Page 2 of 2 (duplex)
TABA EP-PS-1 00-A Revision 8 Page 1 of I MAJOR TASK:
Classify the emergency as conditions indicate.
SPECIFIC TASKS: HOW:
- 1. Evaluate information. 1a. Obtain updated information from:
(1) STA for rad release (2) US for plant status.
(3) US/AUS for status of Damage Control Teams and plant rad conditions.
(4) SCC for security events.
- 2. Choose most appropriate Emergency HELP Classification level from Emergency Emergency Classifications Classification Matrix. See TAB 4 I 3. Manage all Security EAL's. 3a. Go to Tab "G."
- 4. Immediately go to appropriate 4a. "EMERGENCY CLASSIFICATION LEVELS" classification TAB for all other EALs. UNUSUAL EVENT TAB "B" ALERT TAB "C" _
SITE AREA TAB "D"1 GENERAL TAB "E"l
- 5. If a release is in progress, but the 5a. Notify HP at Unit 2 Control criteria for entry to an emergency Point. Request that OSCAR classification is not exceeded, initiate and a Dose Calculator report to off-site Dose Calculations. the Control Room.
TAB B EP-PS-1 00-B Revision 12 Page 1 of 3 MAJOR TASK:
Manage the UNUSUAL EVENT.
SPECIFIC TASKS: HOW:
- 1. Document and communicate the la. Announce to Control Room personnel:
Emergency Classification.
(1) You are assuming the duties of Emergency Director.
(2) Emergency classification.
(3) Time of classification.
lb. Appoint a Control Room Communicator and instruct him to immediately perform EP-PS-126 CR Communicator.
lc. Have the Control Room Communicator perform Local Evacuation/Radiologically Controlled Area Evacuation. If warranted, consider accountability.
Id. If a radiological release is in progress, complete the Protective Action Recommendation Form.
HELP Public Protective Action Recommendation Guide Form See TAB 5 I
- 2. Generate and approve forms 2a. Generate and approve the following:
transmitted by the Control Room (1) Emergency Notification Communicator.
Report (2) Protective Action Recommendation Form 2b. Verbal approval required for Press Releases.
TAB B EP-PS-100-B Revision 12 Page 2 of 3 SPECIFIC TASKS: HOW:
- 3. Notify the Duty Manager/Emergency 3a. Reference the "On-Call Roster" Director of Emergency Event(s). for pager and telephone numbers.
3b. Ensure the Control Room Communicator notifies the SCC, (X 3114), to page key managers.
- 4. Direct US or AUS to assume 4a. US or AUS notified to assume responsibility of OSC Coordinator per OSC responsibilities.
EP-PS-1 32.
- 5. Manage the emergency. 5a. Establish priorities and monitor (1) Plant Status (2) Plant priorities (3) Corrective actions (4) Radiological releases
- 6. Initiate emergency medical response, 6a. Reference SP-00-308 search and rescue when required. (Emergency Medical Response, Search/Rescue)
- 7. If radiological release is suspected/in 7a. Notify HP Dose Calculator that progress, initiate off-site dose off-site dose calculations are calculations. required.
- 8. When contacted, brief the PUBLIC 8a. Brief the PIM on:
INFO. MANAGER, (if time permits). (1) Plant status (2) Radiological condition (3) Emergency Classification Level
TAB B EP-PS-1 00-B Revision 12 Page 3 of 3 SPECIFIC TASKS: HOW:
- 9. Ifplant conditions change reclassify HELP emergency and enter appropriate tab Emergency Classifications for classification level. See TAB 4
- FOR UPGRADING EMERGENCY ALERT TAB "C" SITE AREA TAB "D" GENERAL TAB"E"
- 10. IF a decision to downgrade or 10a. Confirm with (if possible):
terminate the emergency is made, (1) VP-Nuclear Operations perform the following: (2) Duty Manager (3) NRC (optional for UE)
(4) DEP/BRP (optional for UE) 1Ob. Obtain approval from Senior Management prior to implementation.
- 11. Emergency termination: Ila. (1) Instruct OSC (1) Return OPS to normal Coordinator to recall all organization. teams for debriefing.
(2) Deactivate OSC.
(3) Instruct STA to collect and organize paperwork for reconstructing the emergency and its management.
TAB C EP-PS-100-C Revision 10 Page 1 of 3 MAJOR TASK:
Manage the ALERT EMERGENCY.
SPECIFIC TASKS: HOW:
- 1. Document and communicate the la. Announce to Control Room personnel:
Emergency Classification. (1) You are assuming the duties of Emergency Director.
(2) Emergency classification.
(3) Time of classification.
1b. Appoint a Control Room Communicator and instruct him to immediately perform EP-PS-126 CR Communicator.
I 2. Generate and approve forms transmitted by the Control Room 2a. Generate and approve the following::
(1) Emergency Notification Communicator. Report (2) Protective Action Recommendation Form 2b. Verbal approval required for Press Releases.
- 3. Direct US/AUS to assume 3a. US/AUS notified to assume responsibility of OSC Coordinator per OSC responsibilities.
- 4. Manage the emergency until relieved 4a. Establish priorities and monitor:
by TSC Emergency Director. (1) Plant Status (2) Plant priorities (3) Corrective actions (4) Radiological releases
- 5. Initiate emergency medical response, 5a. Reference SP-00-308 search and rescue when required. (Emergency Medical Response, SearchlRescue)
- 6. Initiate Core Damage Assessment. 6a. Notify OSC Coordinator to obtain a Rx Coolant sample.
TAB C EP-PS-1 00-C Revision 10 Page 2 of 3 SPECIFIC TASKS: HOW:
- 7. If Rad release is suspectedfin 7a. Notify OSC Coordinator that progress, initiate off-site dose off-site dose calculations are calculations. required.
- 8. When contacted, brief the following 8a. Brief Managers on:
managers of events: (1) Plant status
- Duty Manager (2) Radiological condition
- Public Info Manager (Iftime (3) Emergency Classification Level permits)
- 9. If plant conditions change reclassify HELP emergency and enter appropriate tab Emergency Classifications for classification level. See TAB 4
- For DOWNGRADING Emergency UNUSUAL TAB "B" EVENT
- For UPGRADING Emergency:
SITE AREA TAB "D" GENERAL TAB "E"
- 10. IF a decision to downgrade or 10a. Confirm with (if possible):
terminate the emergency is made, (1) VP-Nuclear Operations perform the following: (2) Duty Manager (3) NRC (optional for UE)
(4) DEP/BRP (optional for UE) 1Ob. Obtain approval from Senior Management prior to implementation.
- 11. Transfer Emergency Management 11 a. Review the following with TSC duties to TSC Emergency Director. Emergency Director.
(1) Classification of Emergency (2) Radiological conditions in-plant/offsite/projected (3) Priorities and corrective actions taken (4) Plant status (5) Offsite Notifications (PAR's - TAB 5)
TAB C EP-PS-1 00-C Revision 10 Page 3 of 3 SPECIFIC TASKS: HOW:
- 12. Emergency Termination 12a. (1) Instruct OSC (1) Return Ops to normal Coordinator to recall all organization teams for debriefing.
OR (2) Deactivate OSC (2) Recommend creating a (3) Instruct STA to collect restoration organization and organize paperwork for reconstructing the emergency and its management.
12b. Recommend to TSC Emergency Director or Recovery Manager to establish a restoration organization
- See TAB 8 "Restoration Organization Guide" HELP Restoration Organization Guidelines See TAB 8
TAB D EP-PS-1 00-D Revision 12 Page 1 of 3 MAJOR TASK:
Manage the SITE AREA EMERGENCY.
SPECIFIC TASKS: HOW:
- 1. Document and communicate the la. Announce to Control Room personnel:
Emergency Classification. (1) You are assuming the duties of Emergency Director.
(2) Emergency classification.
(3) Time and date of classification.
lb. Appoint a Control Room Communicator and instruct him to immediately perform EP-PS-126 CR Communicator.
- 2. Generate and approve forms transmitted by the Control Room 2a. Generate and approve the following:
(1) Emergency Notification I
Communicator. Report (2) Protective Action Recommendation Form
- 3. Consider the need for emergency HELP exposure considerations/KI tablet PPL Emergency Personnel Dose Assessment issuance. and Protective Action Recommendation Guide See TAB 5
- 4. Direct AUS to assume responsibility 4a. AUS notified to assumne OSC of OSC Coordinator per EP-PS-1 32. responsibility.
- 5. Manage the emergency until relieved 5a. Establish priorities and monitor by TSC Emergency Director. (1) Plant Status (2) Plant priorities (3) Corrective actions (4) Radiological releases
TAB D EP-PS-1 00-D Revision 12 Page 2 of 3 SPECIFIC TASKS: HOW:
Initiate SPECIFIC
- 6. emergency medical response, TASKS:
- 6. Initiate emergency medical response, 6a. Reference SP-00-308 search and rescue when required. (Emergency Medical Response, Search/Rescue)
- 7. Initiate Core Damage Assessment. 7a. Notify OSC Coordinator to obtain a Rx Coolant sample.
- 8. If Rad release suspected/in progress, 8a. Notify OSC Coordinator that initiate off-site dose calculations. off-site dose calculations required.
- 9. When contacted, brief the following 9a. Brief Managers on:
managers of events: (1) Plant status Duty Manager (2) Radiological condition Recovery Manager (3) Emergency Public Info Manager (if time classification level permits)
- 10. If plant conditions change reclassify HELP emergency and enter appropriate tab Emergency Classifications for classification level: See TAB 4
- For DOWNGRADING emergency:
UNUSUAL EVENT TAB "B" ALERT TAB "C"
- For UPGRADING emergency:
GENERAL TAB "E"
- 11. If conditions indicate that the emergency can be downgraded or terminated, provide a recommendation to the TSC/ED or EOF/RM as appropriate.
- 12. Transfer Emergency Management 123a Review the following with TSC duties to TSC Emergency Director. Emergency Director:
(1) Classification of Emergency (2) Radiological conditions in-plant/
offsite/projected (3) Priorities and corrective actions taken (4) Plant status (5) Offsite Notifications
TAB D EP-PS-1 00-D Revision 12 Page 3 of 3 SPECIFIC TASKS: HOW:
12b. Announce to Control Room personnel - TSC has control of emergency - when transfer is complete.
- 13. Emergency Termination 13a. (1) Instruct OSC (1) Return Ops to normal Coordinator to recall all organization teams for debriefing.
OR (2) Deactivate OSC (2) Recommend creating a restoration organization (3) Instruct STA to collect and organize paperwork for reconstructing the emergency and its management.
HELP Restoration Organization Guidelines See TAB 8
TAB E EP-PS-1 00-E Revision 9 Page 1 of 4 MAJOR TASK:
Manage the GENERAL EMERGENCY.
SPECIFIC TASKS: HOW:
- 1. Document and communicate the la. Announce to Control Room personnel:
Emergency Classification.
(1) You are assuming the duties of Emergency Director.
(2) Emergency classification.
(3) Time and date of classification.
lb. Appoint a Control Room Communicator and instruct him to immediately perform EP-PS-126 CR Communicator.
HELP Protective Action Recommendation Form See TAB 9
- 2. When General Emergency declared 2a. Go to TAB 5 "Public Protective make Protective Action Action Recommendation Recommendation (PAR) within 15 Guide" minutes.
2b. Choose appropriate PAR.
2c. Shift Manager shall notify the Senior State Official, using the PAR State Notification Form, at 717-651-2148.
HELP Protective Action Recommendation State Notification Form See TAB 9
TAB E EP-PS-1 00-E Revision 9 Page 2 of 4 SPECIFIC TASKS: HOW:
I 3. Generate and approve forms transmitted by the Control Room 3a. Generate and approve the following:
Communicator. (1) Emergency Notification Report (2) Protective Action Recommendation Form 3b. Verbal approval required for Press Releases.
- 4. Communicate the need for employee NOTE:
emergency exposure Twelve vials of Potassium considerations/KI tablet issuance. Iodide, (KI), are stored in the cabinet outside the Control Room kitchen area and one hundred vials are stored in the Health Physics Instrument Shop.
HELP PPL Emergency Personnel Dose Assessment And Protective Action Recommendation Guide See TAB 6
- 5. Direct US/AUS to assume 5a. AUS notified to assume OSC responsibility of OSC Coordinator per responsibilities.
EP-PS-1 32.
- 6. Manage the emergency until relieved 6a. Monitor and obtain updates on:
by TSC Emergency Director. (1) Plant Status (2) Plant priorities (3) Corrective actions (4) Radiological releases
- 7. Initiate emergency medical response, 7a. Reference SP-00-308 search and rescue when required. (Emergency Medical Response, Search/Rescue)
- 8. Initiate Core Damage Assessment. 8a. Notify OSC Coordinator to obtain a Rx Coolant sample.
TAB E EP-PS-1 00-E Revision 9 Page 3 of 4 SPECIFIC TASKS: HOW:
- 9. If Rad release suspectedlin progress, 9a. Notify HP Dose Calculator/OSC initiate off-site dose calculations. that off-site dose calculations required.
- 10. When contacted, brief the following 10a. Brief Manager on:
managers of events: (1) Plant status
- Duty Manager (2) Radiological condition
- Recovery Manager (3) Emergency
- Public Info Manager (if time classification level permits)
- 11. If plant conditions change reclassify HELP emergency and enter appropriate tab Emergency Classifications I for classification level: See TAB 4
- For DOWNGRADING emergency:
UNUSUAL EVENT TAB "B" ALERT TAB "C" SITE AREA TAB "D"
- 12. If conditions indicate that the emergency can be downgraded or terminated, provide a recommendation to the TSC/ED or EOF/RM as appropriate.
- 13. Transfer Emergency Management 13a. Review the following with TSC duties to TSC Emergency Director. Emergency Director.
(1) Classification of Emergency (2) Radiological conditions in-plant/offsite/projected (3) Priorities and corrective actions taken (4) Plant status (5) Offsite Notifications
TAB E EP-PS-1 00-E Revision 9 Page 4 of 4 SPECIFIC TASKS: HOW:
- 14. Emergency Termination 14a. Instruct STA to collect and (1) Return Ops to normal organize paperwork for organization reconstructing the emergency OR and its management.
(2) Recommend creating a restoration organization HELP Restoration Organization Guidelines See TAB 8
TAB G EP-PS-1 00-G Revision 1 Page 1 of 4 MAJOR TASK:
Manage Site Specific Security Threat or Event EAL series 16.
SPECIFIC TASKS: HOW:
- 1. Determine, document, and la. Determine classification based communicate emergency on EAL.
classification.
lb. Determine appropriate actions based on guidance in this tab.
lc. Announce to Control Room personnel:
(1) I am assuming duties of Emergency Director.
(2) Emergency Classification is (3) Time of classification is Id. Generate and approve ENR K>. and PAR forms to be transmitted by the Control Room Communicator.
I e. Appoint Control Room Communicator.
I
- 2. If security declares condition 4, site 2a. Have Communicator enter specific CREDIBLE threat. EP-PS-126, Tab F.
2b. Activate ALTERNATE NERO per Task 9.
2c. Evacuate site, initiate accountability per Task 10.
2d. Implement Tab B (at Task 4).
- 3. If security declares condition 4, site 3a. Have Communicator enter specific CREDIBLE INSIDER threat. EP-PS-126, Tab F.
3b. Activate ALTERNATE NERO per Task 9.
TAB G EP-PS-100-G Revision 1 Page 2 of 4 SPECIFIC TASKS: HOW:
3c. Evacuate site, initiate accountability per Task 10.
3d. Activate two-man rule per Task 11.
3e. Implement Tab B (at Task 4).
- 4. If security declares condition 4, site 4a. Have Communicator enter specific CREDIBLE IMMINENT threat. EP-PS-126, Tab F.
4b. Activate ALTERNATE NERO per Task 9.
4c. Evacuate site, initiate accountability per Task 10.
4d. Implement Tab C (at Task 3).
- 5. If security declares condition 4, site 5a. Have Communicator enter specific CREDIBLE IMMINENT EP-PS-126, Tab F.
INSIDER threat.
5b. Activate ALTERNATE NERO per Task 9.
5c. Evacuate site, initiate accountability per Task 10.
5d. Activate two-man rule per Task 11.
5e. Implement Tab C (at Task 3).
- 6. If security enters code Blue, Red, or 6a. Declare appropriate Black. emergency classification.
6b. Enter appropriate Tab C, D, or E.
- 7. For any act of sabotage. 7a. Review security EAL series 16.
7b. Declare appropriate Emergency Classification.
TAB G EP-PS-1 00-G Revision 1 Page 3 of 4 SPECIFIC TASKS: HOW:
7c. Enter appropriate Tab B, C, D, orE.
- 8. If Security declares other actual 8a. Review event with security.
security condition 2/4/5.
8b. Declare emergency classification if required.
8c. Enter appropriate Tab B, C, D, or E.
- 9. Activate ALTERNATE NERO (all 9a. Activate 99999 page.
on-call to EOF) when specified by (1) Obtain password from SM Task 2, 3, 4, or 5. key locker.
(2) Dial 1-570-440-1014.
(3) When prompted, enter password XXXX.
(4) When-prompted (voice or rapid three tone signal),
enter "99999."
(5) Return password to SM key locker.
9b. Instruct Security-to:
(1) Validate "99999" pager activation.
(2) Activate the NERO using TNS.
- 10. Evacuate non-essential personnel 10a. Make page announcement from site and initiate accountability twice: "Attention all personnel, when specified in Task 2, 3, 4, or 5. a security emergency has been declared. All non-essential personnel evacuate the site, NERO personnel report to the Emergency Operations Facility."
IOb. Repeat 10a. in five minutes.
1Oc. Initiate accountability in about fifteen minutes or when evacuation is determined complete.
TAB G EP-PS-100-G Revision 1 Page 4 of 4 SPECIFIC TASKS: HOW:
- 11. Activate two-person rule for vital area 11a. Call-out complete second shift access when specified by Task 3 or 5 of personnel:
as personnel become available unless (1) Operations.
doing so will adversely impact (2) Chemistry personnel or plant or security as (3) Health Physics determined by the SSS or SM. (4) Security 1lb. Establish two-person teams (line of sight)
(1) Instruct Unit Supervisor and OSC Coordinator to establish two-person teams.
(2) Instruct Security to establish two-man teams at gatehouse for facility access.
(3) Instruct Accountability Area Leaders to establish two-person teams to report to the TSC.