Dec. 12, 2003 Page 1

of 1 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2003-58852 USER TNFORMATTO G

ACH*R M

EMPL#:28401 CA#: 0363 Addre UCSA2 Pho

  1. 25 194 TRANSMITTAL INFORMATION:

TO:

D 14 12/12/2003 LOCATION:

DOCUMENT CONTROL DESK FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER NUCSA-2)

\\-,iHE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU:

212 -

212 -

EOF COMMUNICATOR: EMERGENCY PLAN-POSITION SPECIFIC PROCEDURE REMOVE MANUAL TABLE OF CONTENTS DATE: 10/30/2003 ADD MANUAL TABLE OF CONTENTS DATE: 12/11/2003 CATEGORY: PROCEDURES TYPE: EP ID:

EP-PS-212 REPLACE:

REV:18 REPLACE:

REV:18 REMOVE: PCAF 2003-1637 REV: N/A ADD: PCAF 2003-1637 REV: N/A UPDATES FOR HARD COPY MANUALS WILL BE DISTRIBUTED WITHIN 5 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON RECEIPT OF HARD COPY. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

S-'

Tab 6

_ EP-PS-212-6 Control #

I EMERGENCY NOTIFICATION REPORT I

1.

Call Status:

El THIS IS A DRILL El THIS IS AN ACTUAL EVENT

2.

This is:

(Communicator's Name)

My telephone number is:

at Susquehanna Steam Electric Station.

Notification time is:

(Callback telephone number)

(Time notification initiated)

3.

EMERGENCY CLASSIFICATION:

[1 UNUSUAL EVENT E1 ALERT

[E The event has been terminated.

El SITE AREA EMERGENCY Ex GENERAL EMERGENCY UNIT:

El ONE E Two El ONE & TWO THIS REPRESENTS AIAN:

Declaration Time:

(Time classification!

termination declared)

DATE:

(Date classification/

termination declared)

El INITIAL DECLARATION El ESCALATION El No CHANGE

} IN CLASSIFICATION STATUS

4.

The Emergency Action Level (EAL) Number is:_

0 BRIEF NON-TECHNICAL DESCRIPTION OF THE EVENT:

l For initial declaration, static update, or escalation, provide current classification EAL number only.

For significant events, or when directed by the ED, RM, or EOFSS, provide a brief description.

For termination, write emergency has been terminated.

5.

THERE IS: El No E1 AN AIRBORNE NON-ROUTINE RADIOLOGICAL RELEASE IN PROGRESS

[1 A LIQUID

6.

WIND DIRECTION IS FROM:

WIND SPEED IS:

mph.

(Data from 10 meter meteorological tower, available on PICSY.)

7.

==

Conclusion:==

E THIS IS A DRILL El THIS IS AN ACTUAL EVENT APPROVED:

Time:

Date:

(ED, RM, or EOFSS)

(Time form approved)

(Date form approved)

EP-AD-000-310, Revision 6, Page 1 of 1

Tab 6 EP-PS-212-6 Affected Unit Control No.

PROTECTIVE ACTION RECOMMENDATION FORM SUSQUEHANNA STEAM ELECTRIC STATION El This is a Drill E This is an Actual Event Preparer The EMERGENCY CLASSIFICATION is:

[3 Unusual Event El Alert El Site Area Emergency E General Emergency Basis: EAL #

This represents:

0 Initial Classification n Escalation E Reduction 0 No Change in the Classification Status Emergency Action(s) implemented onsite:

El None El Local Area Evacuation El Site Accountability Bases:

E Evacuation of non-essential personnel E KI to onsite personnel E Otber The PROTECTIVE ACTION RECOMMENDATION is:

E No Protective Action Recommendation Required O Evacuate -2 miles and Shelter 2-10 miles and advise E ODivert Danville Drinking Water*

citizens to take KI in accordance with the State's E Relocation emergency plans.

0 Control of Access E Evacuate 0-10 miles and advise citizens to take KI E Contamination Controls/Decon in accordance with the State's emergency plans Other

  • Expected arrival of release at Danville:

This represents:

El Initial E Change E No Change in the Protective Action Recommendation EP-AD-000-1 10, Revision 11, Page 1 of 2

Tab 6.

EP-PS-212-6 The BASIS for the Protective Action Recommendation is:

Plant Status Status of Radioactive Release: Event-related release in progress? 3 Yes 0 No Total Site Release Rate

<Tech Requirements Limit.

2 Tech Requirements Limit I

aI Airborne 0

0 Liquid 0l 03 NOTE:

TRM Limits (gCfmin): Noble Gas 1.OOE+6; Iodine 1.04E+2; Particulate 7.72 E+2 (Airborne releases)

Based on:

0 Effluent Monitors 03 Field Measurements 0 Engineering Judgement Data measured in the field confirm release rate estimations: 0 Yes 0 No 03 NIA Weather Conditions:

Wind Speed Wind Direction Dose Projections: 0 TEDE>i 1 rem or thyroid CDE > 5 rem at 2 miles 11 TEDE > 1 rem or thyroid CDE > 5 rem at EPB U TEDE < 1 rem and thyroid CDE < 5 rem at EPB--.

Other:

Approval:

Date/Time:

Emergency Director or Recovery Manager approval required if change in Classification or Protective Action Recommendation.

RPC or DASU approval if no change in the Classification or Protective Action Recommendation.

Transmittal:

0 Verbal 0 Electronic El Both Communicated To:

NAME AGENCY DATEITIME EP-AD-000-1 10, Revision 11, Page 2 of 2