June 2002 Monthly Operating Report for Palisades Plant
ML022040652
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/12/2002
From: Lahti L
Nuclear Management Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML022040652 (4)


Text

NMCla en Committed to Nuclear Excellence

  • Palisades Nuclear Plant Operated by Nuclear Management Company, LLC July 12, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 DOCKET 50-255 - LICENSE DPR PALISADES NUCLEAR PLANT LICENSEE REPORT OF MONTHLY OPERATING DATA Attached are the Monthly Operating Data and Summary of Operating Experience for the Palisades Nuclear Plant for the month of June 2002.

If you have any questions, please contact Mr. Scott Hawn at (616) 764-3179.

Laurie A. Lahti Manager, Licensing CC Regional Administrator, USNRC, Region III NRC Resident Inspector, Palisades LBrandon, Michigan Department of Environmental Quality RJAben, Michigan Department of Labor RDWhale, Michigan Public Service Commission Records Center, INPO SMMclntyre, P-26-204 Attachment 27780 Blue Star Memorial Highway 0 Covert, MI 49043 Telephone: 616.764.2000

SUMMARY

OF OPERATING EXPERIENCE FOR JUNE 2002 The plant operated at essentially full power until June 11, when power was reduced to approximately 50%

due to a trip of one of the Plant's Cooling Tower Pumps. Power was restored on June 14. Turbine Intercept Valve CV-0540 position fluctuations prompted a power reduction to about 90% on June 14 starting at 14:57 hrs. Troubleshooting of the Turbine Intercept Valve control was completed and power restored on June 15. The plant continued power operation at greater than 99% for the remainder of the month.

OPERATING DATA REPORT DOCKET NO: 50-255 DATE (Mo-Da-Yr): 07-03-02 COMPLETED BY: SFPierce TELEPHONE (616) 764-2239 OPERATING STATUS: NOTES:

1. UNIT NAME Palisades
2. REPORTING PERIOD (YrMoDa-YrMoDa): 020601-020630
3. LICENSED THERMAL POWER (Mwt) 2530
4. NAMEPLATE RATING (GROSS Mwe) 811.7
5. DESIGN ELECTRICAL RATING (NET Mwe) 805
6. MAXIMUM DEPENDABLE CAPACITY (GROSS Mwe) 770
7. MAXIMUM DEPENDABLE CAPACITY (NET Mwe) ** 730
8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEM NUMBERS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
10. REASONS FOR RESTRICTIONS, IF ANY:

This Month Yr-to-Date Cumulative

11. HOURS IN REPORTING PERIOD 720.0 4343.0 267638.0
12. NUMBER OF HOURS REACTOR WAS CRITICAL 720.0 3951.4 165178.1
13. REACTOR RESERVE SHUTDOWN HOURS -...
14. HOURS GENERATOR ON-LINE 720.0 3857.6 159648.1
15. UNIT RESERVE SHUTDOWN HOURS .......
16. GROSS THERMAL ENERGY GENERATED (MWH) 1741560 9540502 360665079
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 564842 3152991 114912019
18. NET ELECTRICAL ENERGY GENERATED (MWH) 537795 3007739 108701554
19. UNIT SERVICE FACTOR 100.0% 88.8% 59.7%
20. UNIT AVAILABILITY FACTOR 100.0% 88.8% 59.7%
21. UNIT CAPACITY FACTOR (USING MDC NET)
  • 102.3% 94.9% 58.6%
22. UNIT CAPACITY FACTOR (USING DER NET) 92.8% 86.0% 50.5%
23. UNIT FORCED OUTAGE RATE 0.0% 11.2% 25.8%
    • Based on condenser backpressure Weighted Average (635 MWe used as MDC Net prior to October 1985)

REPORT MONTH June 2002 DOCKET NO. 50-255 UNIT NAME Palisades DATE(Mo/Da/Yr) 07/03/02 COMPLETED BY SFPierce TELEPHONE 616-764-2239 UNIT SHUTDOWNS No. Date Type Duration Reason' Method of Cause / Corrective 2

(YrMoDa) F: Forced (Hours) Shutting Down Actions Comments S: Scheduled NO SHUTDOWNS THIS MONTH

1. 2.

Reason: Method:

A-Equipment Failure (Explain) 1-Manual B-Maintenance or Test 2-Manual Trip/Scram C-Refueling 3-Automatic Trip/Scram D-Regulatory Restriction 4-Other (Explain)

E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)

H-Other (Explain)