Text
NMClea Committed to Nuclear Excellence
- Palisades Nuclear Plant Operated by Nuclear Management Company, LLC February 15, 2002 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 DOCKET 50-255 - LICENSE DPR PALISADES NUCLEAR PLANT LICENSEE REPORT OF MONTHLY OPERATING DATA Attached are the Monthly Operating Data and Summary of Operating Experience for the Palisades Nuclear Plant for the month of January 2002.
If you have any questions, please contact Mr. Rich Schmidt at (616) 764-2185.
Laurie A. Lahti Manager, Licensing CC Regional Administrator, USNRC, Region III NRC Resident Inspector, Palisades LBrandon, Michigan Department of Environmental Quality RJAben, Michigan Department of Labor RDWhale, Michigan Public Service Commission Records Center, INPO SMMclntyre, P-26-204 Attachment 7
.7, 27780 Blue Star Memorial Highway
- Covert, MI 49043 Telephone: 616.764.2000
AVERAGE DAILY UNIT POWER LEVEL DOCKET NO 50-255 UNIT Palisades DATE 2/07/02 COMPLETED BY SFPierce TELEPHONE (616)764-2239 MONTH January 2002 DAY AVERAGE DAILY POWER LEVEL (MWe Net)
- 1.
0
- 2.
0
- 3.
0
- 4.
0
- 5.
0
- 6.
0
- 7.
0
- 8.
0
- 9.
0
- 10.
0
- 11.
0
- 12.
0
- 13.
0
- 14.
0
- 15.
0
- 16.
0 DAY AVERAGE DAILY POWER LEVEL (MWe Net)
- 17.
0
- 18.
0
- 19.
0
- 20.
0
- 21.
134
- 22.
236
- 23.
645
- 24.
788
- 25.
796
- 26.
796
- 27.
795
- 28.
796
- 29.
796
- 30.
797
- 31.
796 INSTRUCTIONS:
On this format, list the average daily unit power level in MWe-NET for each day in the reporting month.
Compute to the nearest whole megawatt.
SUMMARY
OF OPERATING EXPERIENCE FOR JANUARY 2002 The Plant began the month of January 2002, in mode 5 (cold shutdown), to complete repairs to the primary coolant system at the control rod drive housings.
The reactor was brought critical on January 17, at 0734 hrs, and the plant placed on line and synchronized to the electric grid on January 21, at 0524 hrs. Power was gradually increased until full power was reached on January 24, at 1200 hrs. The plant operated at full power for the remainder of the month.
OPERATING DATA REPORT DOCKET NO:
50-255 DATE (Mo-Da-Yr): 02-07-02 COMPLETED BY: SFPierce TELEPHONE (616) 764-2239 OPERATING STATUS:
NOTES:
- 1. UNIT NAME Palisades
- 2. REPORTING PERIOD (YrMoDa-YrMoDa):
020101-020131
- 3. LICENSED THERMAL POWER (Mwt) 2530
- 4. NAMEPLATE RATING (GROSS Mwe) 811.7
- 5. DESIGN ELECTRICAL RATING (NET Mwe) 805
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS Mwe) 770
- 7. MAXIMUM DEPENDABLE CAPACITY (NET Mwe) 730
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEM NUMBERS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
- 10. REASONS FOR RESTRICTIONS, IF ANY:
This Month Yr-to-Date Cumulative
- 11.
HOURS IN REPORTING PERIOD 744.0 744.0 264039.0
- 12.
NUMBER OF HOURS REACTOR WAS CRITICAL 352.4 352.4 161579.1
- 13.
REACTOR RESERVE SHUTDOWN HOURS
- 14.
HOURS GENERATOR ON-LINE 258.6 258.6 156049.1
- 15.
UNIT RESERVE SHUTDOWN HOURS
- 16.
GROSS THERMAL ENERGY GENERATED (MWH) 575063 575063 351699640
- 17.
GROSS ELECTRICAL ENERGY GENERATED (MWH) 186594 186594 111945622
- 18.
NET ELECTRICAL ENERGY GENERATED (MWH) 176982 176982 105870797
- 19.
UNIT SERVICE FACTOR 34.8%
34.8%
59.1%
- 20.
UNIT AVAILABILITY FACTOR 34.8%
34.8%
59.1%
- 21.
UNIT CAPACITY FACTOR (USING MDC NET)
- 32.6%
32.6%
57.9%
- 22.
UNIT CAPACITY FACTOR (USING DER NET) 29.6%
29.6%
49.8%
- 23.
UNIT FORCED OUTAGE RATE 65.2%
65.2%
26.2%
- 24. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE AND DURATION OF EACH):
- 25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):
Forecast Achieved INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIAL OPERATION
- Based on condenser backpressure
- Weighted Average (635 MWe used as MDC Net prior to October 1985)
REPORT MONTH January 2002 DOCKET NO 50-255 UNIT Palisades DATE(Mo/Da/Yr) 02/07/02 COMPLETED BY SFPierce TELEPHONE 616-764-2239 UNIT SHUTDOWNS AND POWER REDUCTIONS No.
Date (YrMoDa)
Type 1 Duration Reason 2 (Hours)
Method of Shutting Down Reactor 3 Licensee Event Report #
System Component Code 4 Code 5 Cause & Corrective Action to Prevent Recurrence 1
02/01/01 F
485.4 hrs A
LER 01-004 AA DRIV Primary Coolant System leakage, repairs consisted of CRDM Upper Housing replacements
- 2.
Reason:
A-Equipment Failure (Explain)
B-Maintenance or Test C-Refueling D-Regulatory Restriction E-Operator Training & License Examination F-Administrative G-Operational Error (Explain)
H-Other (Explain)
- 3.
Method:
1-Manual 2-Manual Scram 3-Automatic Scram 4-Other (Explain)
- 4.
Exhibit G - Instructions for Preparation of Data Entry Sheets for Licensee Event Report (LER) File (NUREG-0161)
- 5.
Exhibit I - Same Source
- 1.
F: Forced S: Scheduled I