IR 05000348/1980023

From kanterella
Jump to navigation Jump to search
IE Insp Repts 50-348/80-23 & 50-364/80-30 on 800814-15. No Noncompliance Noted.Major Areas Inspected:Followup of Noncompliances & Inspector Followup Items Re Part 21 Evaluation & Reporting Matters
ML20008E358
Person / Time
Site: Farley  
Issue date: 09/09/1980
From: Brownlee V, Conlon T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20008E357 List:
References
50-348-80-23, 50-364-80-30, NUDOCS 8010240663
Download: ML20008E358 (3)


Text

mj

>R CE:?

s

4g 4,

UNITED STATES

i NUCLEAR REGULATORY COMMISSION

$

)

REGION 11 e

e

101 MARIETTA sT., N.W., sulTE 3100 ATLANTA, GEORGIA 30303 s

Report Nos. 50-348/80-23 and 50-364/80-30 Licensee: Alabama Power Company 600 North 18th Street Birmingham, AL 35202 Facility Name: Farley Nuclear Plant No. I and 2 Docket Nos. 50-348 and 50-364 License Nos. NPF-2 and CPPR-86 Inspection at Alabama Power Company General Offices, Birmingham, Alabama and Farley Nuclear Plant near Ashford, Alabama Inspector:

[

_f 8' fro w9

V. L. Qownlee D4te' Signed Approved

'

m f - 9 - 70

'7. E. Conlon, Section Chief, RCES Branch Date Signed

)

,

SUMMARY Inspection on August 14-15, 1980 Areas Inspected This special, unannounced inspection involved 9 inspector-hours onsite in the areas of followup of items of noncompliance and inspector followup items relative to Part 21 evaluation and reporting matters.

Results Noncompliance 364/79-19-01, "Part 21 Evaluation" and Inspector Followup Item 348/79-35-01, "Part 21 Procedures Revision" are closed.

i

!

O

.

-

..

-...

.

~4 DETAILS 1.

Persons Contacted Licensee Employees W. C. Petty, Manager, Design and Construction QA J. W. McGowan, Manager Operations QA G. M. Grover, Operations QA Engineer L. L. Bailey, Oper3tions QA Engineer

  • J. D. Woodard, Assistant Plant Manager
  • R. M. Coleman, Engineering Supervisor, Licensing Group
  • H. McClellat, Generating Plant Engineer R. H. Marlow, Reactor Engineering Group
  • L. M. Stinson, Systems Performance Supervisor
  • W. C. Carr, QA Engineer
  • J. W. Kale, Jr., QA Engineer NRC Resident Inspector W. Bradford
  • Attended exit interview 2.

Exit Interview The inspection scope and f.indings were summarized on August 15, 1980 with those persons indicated in Paragraph 1 above.

3.

Licensee Action on Previous Inspection Findings (Clused) Infraction 364/79-19-01 "Part 21 Evaluation".

The inspector reviewed APCO's letter of response dated January 4, 1980, reviewed the revised procedures as identified in the letter of response and held discussions with the responsible design and construction QA personnel regarding Part 21 evaluation and reporting requirements.

The previously identified items of noncompliance related to Part 21 con-trolling procedures and procedure implementation are adequately resolved and responsible personnel are knowledgeable of Part 21 evaluation and reporting requirements. The inspector has no further questions regarding this matter.

4.

Unresolved Items Unresolved items were not identified during this inspection.

5.

(Closed) Inspector Followup Item 348/79-35-01, "Part 21 Procedures Revision".

Farley Nuclear Plant Administrative Procedure FNP-0-AP-62, " Evaluations of Defects and Noncompliances Potentially keportable Under 10 CFR 21" has been

,

-.

.

.

-2-a developed and issued.

The inspector held discussions with responsible General Office and site personnel, reviewed the company policy, geaeral office and site procedures, reviewed Part 21 evaluation records and concluded the following:

Responsible personnel are quite knowledgeable of Part 21 requirements.

a.

b.

Responsible personnel understand the company Part 21 procedures.

The procedures are adequate.

c.

The inspector has no further questions regarding this matter.

,

l

.

"-'M*

wMaMw-6w-4,

.,,%,

,,.,

,