IR 05000298/2021002
ML21221A019 | |
Person / Time | |
---|---|
Site: | Cooper |
Issue date: | 08/09/2021 |
From: | Jason Kozal NRC Region 4 |
To: | Dent J Nebraska Public Power District (NPPD) |
References | |
IR 2021002 | |
Download: ML21221A019 (20) | |
Text
August 9, 2021
SUBJECT:
COOPER NUCLEAR STATION - INTEGRATED INSPECTION REPORT 05000298/2021002
Dear Mr. Dent:
On June 30, 2021, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Cooper Nuclear Station. On July 7, 2021, the NRC inspectors discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.
Two findings of very low safety significance (Green) are documented in this report. One of these findings involved a violation of NRC requirements. We are treating this violation as a non-cited violation (NCV) consistent with Section 2.3.2 of the Enforcement Policy.
A licensee-identified violation which was determined to be of very low safety significance is also documented in this report. We are treating this violation as a non-cited violation (NCV)
consistent with Section 2.3.2 of the Enforcement Policy.
If you contest the violations or the significance of the violations documented in this inspection report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement; and the NRC Resident Inspector at Cooper Nuclear Station.
If you disagree with a cross-cutting aspect assignment or a finding not associated with a regulatory requirement in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; and the NRC Resident Inspector at Cooper Nuclear Station.
J. Dent, Jr. 2 This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.
Sincerely, Signed by Kozal, Jason on 08/09/21 Jason W. Kozal, Chief Reactor Projects Branch C Division of Reactor Projects Docket No. 05000298 License No. DPR-46
Enclosure:
As stated
Inspection Report
Docket Number: 05000298 License Number: DPR-46 Report Number: 05000298/2021002 Enterprise Identifier: I-2021-002-0034 Licensee: Nebraska Public Power District Facility: Cooper Nuclear Station Location: Brownville, NE Inspection Dates: April 1, 2021, to June 30, 2021 Inspectors: R. Alexander, Senior Emergency Preparedness Inspect S. Hedger, Emergency Preparedness Inspector R. Lanfear, Physical Security Specialist A. Siwy, Senior Resident Inspector M. Stafford, Resident Inspector Approved By: Jason W. Kozal, Chief Reactor Projects Branch C Division of Reactor Projects Enclosure
SUMMARY
The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting an integrated inspection at Cooper Nuclear Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information. A licensee-identified non-cited violation is documented in the Results section under Inspection Procedure (IP) 71111.1
List of Findings and Violations
Failure to Maintain in Effect all Provisions of the Fire Protection Program Cornerstone Significance Cross-Cutting Report Aspect Section Mitigating Green [P.1] - 71111.05 Systems NCV 05000298/2021002-01 Identification Open/Closed The inspectors identified a Green finding and associated non-cited violation of Facility Operating License Condition 2.C(4) for failure to maintain in effect all provisions of the approved fire protection program. Specifically, the firefighting foam carts were not maintained in a condition to be effective in mitigating the effects of oil fires.
Failure to Establish Emergency Notification Procedures Consistent with Regulatory Guidance Cornerstone Significance Cross-Cutting Report Aspect Section Emergency Green None (NPP) 71114.01 Preparedness FIN 05000298/2021002-02 Open/Closed The inspectors identified a Green finding for the licensees failure to establish procedures for notification of State and local response organizations for which the content of initial and follow-up messages is consistent with regulatory guidance. The licensee is committed to NRC and industry guidance including NUREG-0654,Section II.E.3, which states, in part, that the established contents of the emergency messages shall contain information about "whether a release is taking place," and similar guidance in NEI 99-02, "Regulatory Assessment Performance Indicator Guideline."
Additional Tracking Items
None.
PLANT STATUS
Cooper Nuclear Station began the inspection period at rated thermal power. On May 7, 2021, power was lowered to approximately 70 percent for a control rod sequence exchange. The plant was returned to rated thermal power on May 8, 2021. On May 9, 2021, power was lowered to approximately 84 percent for a control rod sequence exchange. The plant was returned to rated thermal power on May 10, 2021. The unit remained at rated thermal power for the remainder of the inspection period.
INSPECTION SCOPES
Inspections were conducted using the appropriate portions of the IPs in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.
Starting on March 20, 2020, in response to the National Emergency declared by the President of the United States on the public health risks of the coronavirus (COVID-19), resident and regional inspectors were directed to begin telework and to remotely access licensee information using available technology. During this time, the resident inspectors performed periodic site visits each week, increasing the amount of time on site as local COVID-19 conditions permitted.
As part of their onsite activities, resident inspectors conducted plant status activities as described in IMC 2515, Appendix D; observed risk significant activities; and completed on site portions of IPs. In addition, resident and regional baseline inspections were evaluated to determine if all or a portion of the objectives and requirements stated in the IP could be performed remotely. If the inspections could be performed remotely, they were conducted per the applicable IP. In some cases, portions of an IP were completed remotely and on site. The inspections documented below met the objectives and requirements for completion of the IP.
REACTOR SAFETY
71111.01 - Adverse Weather Protection
Seasonal Extreme Weather Sample (IP Section 03.01) (1 Sample)
- (1) The inspectors evaluated readiness for seasonal extreme weather conditions prior to the onset of seasonal high temperatures for the following systems:
Heating, ventilation, and air conditioning for the diesel generator building on May 14, 2021 Heating, ventilation, and air conditioning for the reactor building on May 14, 2021
71111.04 - Equipment Alignment
Complete Walkdown Sample (IP Section 03.02) (1 Sample)
- (1) The inspectors evaluated system configurations during a complete walkdown of the residual heat removal service water booster pump D on April 16, 2021.
71111.06 - Flood Protection Measures
Inspection Activities - Internal Flooding (IP Section 03.01) (1 Sample)
The inspectors evaluated internal flooding mitigation protections in the:
- (1) Service water booster pump room on May 14, 2021
71111.11Q - Licensed Operator Requalification Program and Licensed Operator Performance
Licensed Operator Performance in the Actual Plant/Main Control Room (IP Section 03.01)
(1 Sample)
- (1) The inspectors observed and evaluated licensed operator performance in the control room during downpower activities and rod pattern adjustment on May 8, 2021.
Licensed Operator Requalification Training/Examinations (IP Section 03.02) (1 Sample)
- (1) The inspectors observed and evaluated the licensed operator requalification scenario on April 20, 2021.
71111.12 - Maintenance Effectiveness
Maintenance Effectiveness (IP Section 03.01) (1 Sample)
The inspectors evaluated the effectiveness of maintenance to ensure the following structures, systems, and components (SSCs) remain capable of performing their intended function:
- (1) Reactor equipment cooling system near A(1) on May 5, 2021
Quality Control (IP Section 03.02) (1 Sample)
The inspectors evaluated the effectiveness of maintenance and quality control activities to ensure the following SSC remains capable of performing its intended function:
- (1) Emergency diesel generator 1 quality control inspections during maintenance window on April 15, 2021.
71111.13 - Maintenance Risk Assessments and Emergent Work Control
Risk Assessment and Management Sample (IP Section 03.01) (5 Samples)
The inspectors evaluated the accuracy and completeness of risk assessments for the following planned and emergent work activities to ensure configuration changes and appropriate work controls were addressed:
- (1) Yellow risk during emergency diesel generator Division 1 maintenance on April 8, 2021
- (2) Yellow risk during high-pressure coolant injection maintenance on April 20, 2021
- (3) Emergent jacket water leak repair of emergency diesel generator 2 on April 29, 2021
- (4) Work Week 2118, residual heat removal, residual heat removal service water, and 4160 undervoltage testing on May 6, 2021
- (5) Yellow risk during reactor equipment cooling B maintenance on May 21, 2021
71111.15 - Operability Determinations and Functionality Assessments
Operability Determination or Functionality Assessment (IP Section 03.01) (4 Samples)
The inspectors evaluated the licensee's justifications and actions associated with the following operability determinations and functionality assessments:
- (1) High-pressure coolant injection minimum flow switch out of tolerance on April 30, 2021
- (2) Fire cart foam concentration results on May 13, 2021
- (3) Planned limiting condition of operation not entered during reactor equipment cooling maintenance on May 20, 2021
- (4) Emergency diesel generator 2 jacket water leak on June 29, 2021
71111.19 - Post-Maintenance Testing
Post-Maintenance Test Sample (IP Section 03.01) (6 Samples)
The inspectors evaluated the following post-maintenance test activities to verify system operability and functionality:
- (1) Control rod drive 111 (42-11) instrument block valve repair on April 7, 2021
- (2) Emergency diesel generator 1 lube oil and jacket water heat exchanger inspections on April 8, 2021
- (3) Emergency diesel generator 1 jacket water check valve repairs on April 9, 2021
- (4) Emergency diesel generator 1 startup air valve replacements on April 13, 2021
- (5) Residual heat removal service water booster pump C on April 14, 2021
- (6) High-pressure coolant injection system valves on April 21, 2021
71111.22 - Surveillance Testing
The inspectors evaluated the following surveillance tests:
Surveillance Tests (other) (IP Section 03.01)
- (1) Emergency diesel generator 2 surveillance following jacket water leak repair on May 3, 2021
- (2) Core spray pump A surveillance on May 7, 2021
Inservice Testing (IP Section 03.01) (1 Sample)
- (1) Division 1 service water booster pumps A and C on April 8, 2021
71114.01 - Exercise Evaluation
Inspection Review (IP Section 02.01-02.11) (1 Sample)
- (1) The inspectors evaluated the biennial emergency plan exercise conducted on May 25 and 26, 2021. The exercise scenario simulated a rapidly escalating series of seismic events of increasing severity resulting a loss of coolant accident, fuel clad damage, and ultimately failure of both primary and secondary containment leading to an unmonitored release to the environment. Additionally, the inspectors evaluated an out of sequence drill which continued the scenario from the prior day and demonstrated the use of extensive damage mitigation strategies consistent with Title 10 of the Code of Federal Regulations (10 CFR) 50.155(b)(2), to mitigate the spent fuel pool leakage, caused by an additional simulated seismic aftershock.
71114.04 - Emergency Action Level and Emergency Plan Changes
Inspection Review (IP Section 02.01-02.03) (1 Sample)
- (1) The inspectors evaluated the following submitted Emergency Plan and Risk Significant Implementing Procedure changes:
CNS 10 CFR Part 50, Appendix E, On-Shift Staffing Analysis, Revision 3 Emergency Plan Implementing Procedure 5.7.6, Notifications, Revision 78 This evaluation does not constitute NRC approval.
71114.06 - Drill Evaluation
Drill/Training Evolution Observation (IP Section 03.02) (1 Sample)
The inspectors evaluated:
- (1) Emergency preparedness drill on April 6,
OTHER ACTIVITIES - BASELINE
===71151 - Performance Indicator Verification The inspectors verified licensee performance indicators submittals listed below:
BI01: Reactor Coolant System (RCS) Specific Activity Sample (IP Section 03.10) ===
- (1) April 1, 2020, through March 31, 2021
BI02: RCS Leak Rate Sample (IP Section 03.11) (1 Sample)
- (1) April 1, 2020, through March 31, 2021
EP01: Drill/Exercise Performance (IP Section 03.12) (1 Sample)
- (1) July 1, 2020, through March 31, 2021
EP02: ERO Drill Participation (IP Section 03.13) (1 Sample)
- (1) July 1, 2020, through March 31, 2021
EP03: Alert & Notification System Reliability (IP Section 03.14) (1 Sample)
- (1) July 1, 2020, through March 31, 2021
71152 - Problem Identification and Resolution
Annual Follow-up of Selected Issues (IP Section 02.03) (1 Sample)
The inspectors reviewed the licensees implementation of its corrective action program related to the following issues:
- (1) Operating experience smart sample (OpESS) 2020/01 (ADAMS Accession No. ML20220A261) on May 28,
INSPECTION RESULTS
Failure to Maintain in Effect all Provisions of the Fire Protection Program Cornerstone Significance Cross-Cutting Report Aspect Section Mitigating Green [P.1] - 71111.05 Systems NCV 05000298/2021002-01 Identification Open/Closed The inspectors identified a Green finding and associated non-cited violation of Facility Operating License 2.C(4) for failure to maintain in effect all provisions of the approved fire protection program. Specifically, the firefighting foam carts were not maintained in a condition to be effective in mitigating the effects of oil fires.
Description:
On March 2, 2021, the inspectors conducted a walkdown of a pre-fire plan, which included one of the portable firefighting foam carts credited in the licensees NFPA 805 fire protection program. The inspectors questioned the frequency of the preventive maintenance (PM) for the foam concentrate in those carts, which consisted of a biennial analysis of the foam concentrate. The licensee canceled the PM in 2006 with the inaccurate technical basis that National Fire Protection Association (NFPA) 11 standard was not applicable because they are not systems and that the shelf life of the foam concentrate in the carts is 20-25 years.
The portable firefighting foam carts are covered as portable systems by the NFPA 11 standard because they are, "foam-producing equipment, materials, hose, and so forth, that are transported by hand." Additionally, the NFPA 11 standard also provides a list of firefighting systems that the standard is not applicable to and these portable firefighting foam carts do not fall under any of those categories, which are: "chemical foams and systems (considered obsolete), deluge foam-water sprinkler or spray systems (see NFPA 16), foam-water closed-head sprinkler systems (see NFPA 16), combined agent systems, mobile foam apparatus (see NFPA 1901), Class A foam and systems (see NFPA 1150)." The shelf life of 20-25 years that was quoted by the licensee from the vendor technical sheets applies only to foam concentrate in unopened manufacturer containers, which does not include the foam concentrate poured into in the licensee carts. The NFPA 11 standard requires testing the foam concentration and the foam carts on an annual basis and the vendor technical datasheets recommend the NFPA 11 standard. There is no other standard or industry guidance for the testing and maintenance of firefighting foam and foam delivery systems such as portable firefighting foam carts.
The applicable procedure for canceling the PM in 2006 was Procedure 7.0.2, Preventative Maintenance Program Implementation, Revision 37. It requires, in part, that a PM change notification has accurate information and that the technical bases of the PM process is maintained current and accurate. The current applicable Procedure 3-CNS-DC-324, Preventative Maintenance Program, has the same requirements. In 2017, the licensee initiated reinstatement of the performance of the PM on a yearly basis based on feedback from an industry review. In July 2019, the PM was performed and in 2020, the licensee changed the annual PM to biennial with the same inaccurate basis that was used to remove the PM in 2006.
On September 24, 2019, the vendor completed the analyses of the foam concentrate samples from each of the foam carts as required by the PM. As a result of the analyses, the licensee entered a condition report into their corrective action program to replace the foam concentrate in the carts because of the vendor comments: "Based on physical properties and lack of viscosity, this sample doesn't appear to be Thunderstorm 1x3 ATC F601A.
Replacement is recommended." The licensee determined that the foam in the carts was functional based on their erroneous assumption that the test results were invalid due to the licensee not following the recommended guidance for taking samples. The work order to replace the foam concentrate was originally scheduled for 1 year after the samples were removed from the carts but was later rescheduled to 2 years after the removal of the samples.
The 2019 results of the foam concentrate analyses compared to the manufacturer datasheet show that for appearance, density, pH, and viscosity all the samples were outside of the manufacturer's specifications. Additionally, the reports for each sample listed "N/A" for the first and second fire extinguishment time, while the fire application time was listed as 90 seconds with application on 1000 milliliters of acetone.
The NFPA 11 standard, Section D.3, provides guidance for the interpretation of foam test results. It states, in part, "where the intent of conducting the tests is to check the operating efficiency or standby condition, it is necessary only to compare the results with the manufacturers' standards. The manufacturers should be consulted if any appreciable deviations occur." The licensee did not compare the physical properties of the samples to the vendor datasheets and did not discuss the results with the vendor or the manufacturer.
As a result of the inspectors initial questioning, the licensee reclassified the work order to replace the foam concentrate in the carts from the lowest priority to the highest. The work order was performed 14 weeks earlier than it was scheduled, which would have been 2 years after the samples were taken. The licensee discovered the contents of one of the carts was partially congealed. They entered this condition into the corrective action program, took the cart out of service, and staged a foam eductor in its place. After the foam concentrate in the carts was replaced, the vendor clarified their 2019 results to more clearly state that the samples did not extinguish fires.
Corrective Actions: The licensee replaced the foam concentrate in all portable firefighting foam carts and staged a foam eductor for the cart that was removed from service. The licensee initiated a condition report to revise the PM to be performed yearly, as required by the NFPA 11 standard.
Corrective Action References: Condition Reports CR-CNS-2021-01477, CR-CNS-2021-01583, CR-CNS-2021-01787, and CR-CNS-2021-01858
Performance Assessment:
Performance Deficiency: The inspectors determined that failure to follow the requirements of Procedure 7.0.2, Preventative Maintenance Program Implementation, and Procedure 3-CNS-DC-324, Preventative Maintenance Program, was a performance deficiency that was within the licensees ability to foresee and prevent. Specifically, the licensee did not provide accurate technical bases for canceling the PM or for extending the reinstated PM from yearly to biennial, which resulted in the foam concentrate in the carts being unable to extinguish a fire.
Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the Protection Against External Factors attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the delay in the extinguishment of a fire would allow more time for a fire to damage plant equipment.
Significance: The inspectors assessed the significance of the finding using Appendix F, Fire Protection and Post - Fire Safe Shutdown SDP. The inspectors assessed the significance of the finding using Inspection Manual Chapter (IMC) 0609.04, Initial Characterization of Findings, and IMC 0609, Appendix F, Attachment 1, and determined the finding to be of very low safety significance (Green) because the foam carts are classified as portable fire extinguishers not used for hot work fire watches.
Cross-Cutting Aspect: P.1 - Identification: The organization implements a corrective action program with a low threshold for identifying issues. Individuals identify issues completely, accurately, and in a timely manner in accordance with the program. Specifically, the licensee did not completely and accurately assess the vendor lab results of the foam concentrate analysis in a timely manner to identify that the foam concentrate would not extinguish fires.
Enforcement:
Violation: The Facility Operating License Condition 2.C(4) requires, in part, that the licensee maintain in effect all provisions of the approved fire protection program. The licensee included the foam carts as part of their Engineering Evaluations EE-12-013 and EE-15-011, which supported the basis for their License Amendment Request (ML121220216) dated April 24, 2012, to revise their fire protection licensing basis to NFPA 805. The foam carts are specifically listed in the bases sections of Table B-3, Fire Area Transition, for Fire Areas RB-V, RB-P, and RB-T of the License Amendment Request. The foam carts are also listed as part of the licensees fire protection program in Chapter X, Section 9.3.2.7, Portable Extinguishers, of the Updated Safety Analysis Report. Contrary to the above, between September 2019, and March 2021, the licensee failed to maintain in effect all provisions of the approved fire protection program. Specifically, the licensee failed to maintain the foam carts, which were required for implementation of the fire protection program, in a condition to be available to perform the required functions.
Enforcement Action: This violation is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
Licensee-Identified Non-Cited Violation 71111.13 This violation of very low safety significance was identified by the licensee and has been entered into the licensee corrective action program and is being treated as a non-cited violation, consistent with Section 2.3.2 of the Enforcement Policy.
Violation: Title 10 CFR 50.65(a)(4), Requirements for monitoring the effectiveness of maintenance at nuclear power plants, requires, in part, that the licensee shall manage the increase in risk that may result from maintenance activities.
Contrary to the above, on May 18, 2021, the licensee failed to manage the increase in risk associated with planned maintenance activities. Specifically, maintenance personnel performed hot work activities in an area that was specifically posted to prohibit hot work as part of a fire risk management action for a separate system unavailability. The licensee identified this after the hot work activity had been completed while operations personnel were reviewing narrative logs.
Significance/Severity: Green. The inspectors assessed the significance of the finding using IMC 0609, Appendix K, Maintenance Risk Assessment and Risk Management Significance Determination Process, and determined the finding to be of very low safety significance (Green) because the issue was associated with risk management actions only, and the associated incremental core damage probability was 5.1E-10, less than 1E-6.
Corrective Action References: Condition Report CR-CNS-2021-02419 Failure to Establish Emergency Notification Procedures Consistent with Regulatory Guidance Cornerstone Significance Cross-Cutting Report Aspect Section Emergency Green None (NPP) 71114.01 Preparedness FIN 05000298/2021002-02 Open/Closed The inspectors identified a Green finding for the licensees failure to establish procedures for notification of State and local response organizations for which the content of initial and follow-up messages is consistent with regulatory guidance. The licensee is committed to NRC and industry guidance including NUREG-0654,Section II.E.3, which states, in part, that the established contents of the emergency messages shall contain information about "whether a release is taking place," and similar guidance in NEI 99-02, "Regulatory Assessment Performance Indicator Guideline."
Description:
As a part of the May 25, 2021, biennial emergency preparedness exercise, the scenario included simulated conditions where a series of seismic events caused all three Fission Product Barriers to be lost as well as a breach in the secondary containment building siding. This resulted in a direct release path for gaseous radioactive materials from the plant to the environment which could not be directly monitored by installed instrumentation (i.e., an unmonitored release). In the scenario, the Fuel Clad and Reactor Coolant System Fission Product Barriers had been lost, resulting in the licensee declaring a Site Area Emergency at 8:57 a.m. At 10:20 a.m., a subsequent, larger seismic event was simulated to occur which resulted in the loss of the Containment Fission Product Barrier, and this seismic event also caused a portion of the reactor building (secondary containment) siding to fall off at the 1001 foot elevation.
With the loss of the third Fission Product Barrier, the licensee declared a General Emergency (GE) at 10:29 a.m. The licensee subsequently developed a Protective Action Recommendation (PAR) to evacuate the Emergency Planning Zone Sectors corresponding with a 2-mile radius around the plant and 5 miles downwind, and provided the official notification of the GE and PAR information to the Offsite Response Organizations (OROs),including the States of Nebraska and Missouri, at 10:38 a.m.. At the time at which the GE was declared and PAR developed, the licensee's Emergency Response Organization (ERO)representatives in the Emergency Operations Facility were aware of the simulated additional failure of the reactor building siding and unmonitored release path for gaseous radioactive materials to the environment. However, in that notification to the OROs, the licensee did not communicate that there was a "release in progress" attributable to the simulated events.
Specifically, the licensee's notification form to the OROs had been established such that the section would only be marked indicating a release of liquid or gaseous radioactive materials was occurring if the release was quantified and was in excess of the limits associated with the Notice of Unusual Event (NOUE) thresholds. Because the release was from an unmonitored point from the station at the time of the GE, the licensee's notification form transmitted at 10:38 a.m. indicated, "There is No Release of Radioactive Material Greater than NOUE Limits," despite the EROs awareness that there was a release attributable to the event ongoing at the time, with no basis for determining it was below NOUE Limits. Subsequently, at 11:32 a.m., the licensee provided a periodic update notification to the OROs which still included the statement, "There is No Release of Radioactive Material Greater than NOUE Limits;" however, the licensee's Emergency Director handwrote into the form prior to transmittal the following statement, "An unmonitored release path exists. It is not yet quantified."
Therefore, for a period of approximately 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after the GE was declared, the licensee had not provided the information to the States' emergency decision makers that an unmonitored release of radioactive materials attributable to the (simulated) events was ongoing (whether quantified or not). As such, the States' emergency decisionmakers were not afforded all of the relevant information regarding the release associated with the event to support the States' protective action decision making for the protection of the public and the States' emergency responders who were deploying to the immediate areas around the plant.
The content of the offsite notification form had been established and accepted by the licensee since 1995. Specifically, in follow-up inspection it was revealed that the licensee's notification form had originally included the statement to correctly mark that, "There is / is not a release associated with this event" (without including any thresholds for release levels), but the licensee had changed the form in consultation with the OROs (using the change process described in 10 CFR 50.54(q)) as a corrective action for an NRC-identified weakness in exercise performance in 1994. The associated 1994 inspection report (ADAMS Accession Nos. ML20077F356 and ML20077F361) and subsequent documentation/communications between the licensee and NRC Region IV (ADAMS Accession Nos. ML20077M675, ML20083L075, and ML20083L080) on the exercise weakness showed that the weakness identified was related to inconsistent communications from the licensee to all OROs (States and NRC). Specifically, the 1994 inspection report documented that during that exercise, in the licensee's notification of an Alert to the State/Locals, they indicated there was an airborne radioactive release in progress; however, in the licensee's subsequent notification to the NRC a few minutes later, no information regarding the airborne release was included. The conversations and other aspects discussed between the NRC and the licensee on the corrective actions at the time were not further documented, but a subsequent 1995 inspection report (ADAMS Accession No. ML20083L080) described that the licensee made changes to the applicable emergency procedures to include a definition of release and updated training materials. While the 1995 inspection report indicated that the licensee's corrective actions were satisfactory, such statements included in Regional Inspection Reports do not constitute NRC approval of an Emergency Plan change because the authority to approve operating reactor license changes has been delegated by the Commission to the Office of Nuclear Reactor Regulation from the Commission, and not to NRC regional offices.
The inspectors determined that the NRC guidance relative to ORO notification forms and the required information regarding the status of any release has been well established over the years. Specifically, in NUREG-0654, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants,"
Revision 1 (published November 1980),Section II.E.3 states, in part, that the established contents of the emergency messages shall contain information about "whether a release is taking place." The inspectors found that the Cooper Emergency Plan, in Appendix B, Section E.3, includes the identical wording from NUREG-0654,Section II.E.3, relative to "whether a release is taking place" in the Plan's cross-reference with NUREG-654. Additional NRC guidance amplifying that the content of ORO notification messages shall include whether "radioactive release attributable to the event is taking place" has been described in all revisions of NEI 99-02, "Regulatory Assessment Performance Indicator Guideline," after it was endorsed by the NRC in Regulatory Issue Summary (RIS) 2000-08, Voluntary Submission of Performance Indicator Data, Revision 1. This document, and its guidance, are integrated into the licensees procedures and defined in part the content of these notifications relative to the Drill and Exercise Performance (DEP) Performance Indicator (PI).
Such notifications shall include appropriate information as to "whether a release is taking place" for an "Accurate" notification message to receive DEP PI opportunity success credit.
Based on their search, the inspectors determined that NRC guidance has been consistent in requiring that ORO notification forms include whether a release attributable to the event is occurring/has occurred. While NRC guidance has acknowledged that the information on the magnitude of the release attributed to the event may be included as part of the notification forms, such information is always expected to be secondary and distinct from the "release is occurring" determination.
Corrective Actions: The licensee entered this issue into the corrective action program and initiated discussions with the OROs to modify the notification form to ensure the status of a release and the quantity of any such release are two separate elements on the negotiated notification form.
Corrective Action References: CR-CNS-2021-03275
Performance Assessment:
Performance Deficiency: The licensee failed to establish procedures for notification of State and local response organizations for which the content of initial and follow-up messages are consistent with regulatory guidance, including NUREG-0654, Revision 1, and NEI 99-02, the guidance of both which the licensee has integrated into its processes and procedures.
Screening: The inspectors determined the performance deficiency was more than minor because it was associated with the ERO Performance attribute of the Emergency Preparedness cornerstone and adversely affected the cornerstone objective to ensure that the licensee is capable of implementing adequate measures to protect the health and safety of the public in the event of a radiological emergency. Specifically, the failure to provide complete information to the OROs regarding the release status associated with an emergency directly impacts the ORO decision maker's ability to make the most informed protective action decisions for the protection of the public and relative to the ORO's emergency workers responding to the event.
Significance: The inspectors assessed the significance of the finding using Inspection Manual Chapter 0609, Appendix B, Emergency Preparedness SDP. The finding was determined to be of very low safety significance (Green). Specifically, the inspectors determined that while the performance deficiency was related to a risk significant planning standard (RSPS), 10 CFR 50.47(b)(5), the failure did not result in a loss or degradation of the RSPS function, in that the notification process in which the licensee communicated the GE and PAR to all of the applicable OROs was completed in a timely manner, and most aspects of the information were accurate. However, the inspectors determined that the content of the message related to the release status for the notification was inconsistent with well-established NRC guidance. Consistent with IMC 0609, Appendix B, Attachment 2, for those performance deficiencies where a RSPS function is not found to be lost or degraded, the significance of such issues is Green.
Cross-Cutting Aspect: Not Present Performance. No cross-cutting aspect was assigned to this finding because the inspectors determined the finding did not reflect present licensee performance. Specifically, the licensee made the change to the offsite notification form in 1995, and despite many opportunities in demonstrating its appropriate use in subsequent exercises, it appears the combination of a challenging scenario and other issues with ERO performance during the 2021 exercise only now revealed the inadequacies of the form.
Enforcement:
Inspectors did not identify a violation of regulatory requirements associated with this finding.
EXIT MEETINGS AND DEBRIEFS
The inspectors verified no proprietary information was retained or documented in this report.
On July 7, 2021, the inspectors presented the integrated inspection results to Mr. J. Dent, Jr., and other members of the licensee staff.
On July 14, 2021, the inspectors presented the emergency preparedness exercise inspection results to Mr. K. Dia, General Manager - Plant Operations, and other members of the licensee staff.
DOCUMENTS REVIEWED
Inspection Type Designation Description or Title Revision or
Procedure Date
71111.01 Procedures 2.1.14 Seasonal Weather Preparations 36
71111.04 Procedures 2.2A.RHRSW.DIV2 RHR Service Water Booster Pump System Component 11
Checklist (Div 2)
71111.06 Miscellaneous NEDC 09-102 Internal Flooding - HELB, MELB, and Feedwater Line 3
Break
71111.11Q Procedures 10.13 Control Rod Sequence and Movement Control 77
10.9 Control Rod Scram Time Evaluation 72
2.1.10 Station Power Changes 120
2.2.6 Condensate System 100
Work Orders WO 5266938
71111.12 Corrective Action CR-CNS- 2020-00744, 2020-02917, 2020-05737, 2021-01024
Documents
Miscellaneous Maintenance Rule Function REC-F01 Performance Criteria 6
Basis
Procedures 7.3.26.9 Essential 3M Tape Installation 9
7.3.28.1 Lead Removal/Installation and Lug Installation 32
Work Orders WO 5210671, 5337005, 5346586
71111.13 Corrective Action CR-CNS- 2021-02091, 2021-02100, 2021-02145, 2021-02263, 2021-
Documents 02265, 2021-02266, 2021-02419
Miscellaneous Protected Equipment Posting for REC Maintenance
Window
Protected Equipment Posting for Diesel Generator Division
Work W
Protected Equipment Posting for High-Pressure Coolant
Injection System Work Week
Protected Equipment Posting for Emergent Diesel
Generator Division 2 Work
Protected Equipment Posting for RHR and RHRSW Work
FP21-FP-SD-16 Fire Impairment Log
(1-8)
Procedures 0-CNS-WM-104A On-Line Fire Risk Management Actions 7
0-Protect-EQP Protected Equipment Program 57, 58
Inspection Type Designation Description or Title Revision or
Procedure Date
Work Orders WO 5396090, 5396180, 5399040
71111.15 Corrective Action CR-CNS- 2021-02033, 2021-02034, 2021-02061, 2021-02091, 2021-
Documents 02100, 2021-02145, 2021-02439
71111.19 Procedures 14.17.1 DG-1 Annual Calibration 41
2.2.70 RHR Service Water Booster Pump System 95
6.1DG.101 Diesel Generator 31 Day Operability Test 92
Work Orders WO 5288700, 5296094, 5336948, 5346632, 5368019
71111.22 Procedures 6.1CS.101 Core Spray Test Mode Surveillance Operation 34
6.1SWBP.101 RHR Service Water Booster Pump Flow Test and Valve 38
Operability Test
6.2DG.101 Diesel Generator 31 Day Operability Test 88
Work Orders WO 5295275, 5296906, 5396090
71114.01 Corrective Action CR-CNS- 2018-04629, 2018-04662, 2018-04855, 2018-08663, 2019-
Documents 01246, 2019-03881, 2019-03882, 2020-00007, 2020-
00929, 2020-01015, 2020-01179, 2020-01341, 2020-
2747, 2021-00911
Corrective Action CR-CNS- 2021-03275, 2021-03276, 2021-03277
Documents
Resulting from
Inspection
Miscellaneous Cooper Nuclear Station - 2021 NRC Biennial Exercise 06/01/2021
Management Debrief
Exercise Participant Logs and Records from the EOF, TSC, 05/25/2021
OSC, JIC, and Control Room Simulator
21 May IPX Exercise Scenario (Rev. 0) 05/14/2021
Procedures 0-EN-EP-306 Drills and Exercises 10C0
2.4FPC Fuel Pool Cooling Trouble 39
5.3ALT- Alternate Core Cooling Mitigating Strategies 64
STRATEGY
5.7.1 Emergency Classification 67
5.7.1.1 Emergency Classification Process 0
5.7.17 CNS-Dose Assessment 52
5.7.18 Off-Site and Site Boundary Monitoring 25
5.7.19 On-Site Radiological Monitoring 15
Inspection Type Designation Description or Title Revision or
Procedure Date
5.7.2 Emergency Director EPIP 40
5.7.6 Notification 78
5.7ENS ENS Communicator 11
71114.04 Miscellaneous 50.54(q) Screen On-Shift Staffing Analysis, Rev. 3 04/01/2021
No. 2021-08
50.54(q) Screen EPIP 5.7.6, Notification, Rev. 78 03/23/2021
No. 2021-14
71151 Corrective Action CR-CNS- 2020-02902, 2020-03004, 2020-03613, 2020-04543, 2021-
Documents 02253
Miscellaneous DEP PI Opportunity Data Packages - Emergency
Response Organization Watchbill Turnover Opportunities
(7/13/20, 7/27/20, 12/14/20, 1/18/21, 3/29/21) and Full
Team Drill (2/2/21)
DEP PI Opportunity Data Packages - Licensed Operator
Requalification Opportunities (7/1/20, 7/8/20, 11/25/20, &
2/18/20)
0-EN-LI-114, ERO Drill Participation Performance Indicator and Data
Att. 9.3 Review Forms - 3Q/2020, 4Q/2020, & 1Q/2021
0-EN-LI-114, ANS Performance Indicator Documentation & Data Form -
Att. 9.3 July, August, September, October, November, & December
20
0-EN-LI-114, ANS Performance Indicator Documentation & Data Form -
Att. 9.3 January, February, & March 2021
Procedures 0-EN-FAP-EP-005 Emergency Preparedness Performance Indicators 14C0
0-EN-LI-114 Regulatory Performance Indicator Process 17C0
6.LOG.601 Daily Surveillance Log - Modes 1, 2, and 3 141
EPDG 2, Att. C-1 Semi-Monthly Alert and Notification System Siren Testing 21
71152 Corrective Action CR-CNS- 2020-02436
Documents
17