05000272/LER-1982-010, Forwards LER 82-010/03X-1.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-010/03X-1.Detailed Event Analysis Encl
ML20041F749
Person / Time
Site: Salem 
Issue date: 03/03/1982
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20041F740 List:
References
NUDOCS 8203170381
Download: ML20041F749 (3)


LER-1982-010, Forwards LER 82-010/03X-1.Detailed Event Analysis Encl
Event date:
Report date:
2721982010R00 - NRC Website

text

O PSIEG Public Service Electric and Gas Company P.O. Box E. Hancocks Bridge, New Jersey 08038 Salem Generating Station March 3, 1982 Mr.

R. C. Ilaynes Regional Administrator USNRC Region 1 631 Park Avenue King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

LICENSE NO. DPR-70 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 82-10/03X-1 Pursuant to the requirements of Salem Generating Station Unit No. 1, Technical Specifications, Section 6.9.1.9.d, we are submitting Licensee Event Report for Reportable Occurrence 82-10/03X-1.

This report is required within thirty (30) days of the occurrence.

Sincerely yours,

}l, fc fc'LeJ H.

J. Midura General Manager -

Salem Operations 1

FD:al CC:

Distribution i

The Enerav People i

8203170381 820305 l

PDR ADOCK 05000272 waeum u st :

i

Report Number:

82-10/03X-1 Report Date:

03-03-82 Occurrence Date:

02-01-82 Facility:

Salem Generating Station, Unit 1 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Temporary Spent Fuel Cooling Crosstic - Leak.

This report was initiated by Incident Report 82-027.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 6 - Rx Power 0% - Unit Load 0 MWe DESCRIPTION OF OCCURRENCE:

At 0915 hours0.0106 days <br />0.254 hours <br />0.00151 weeks <br />3.481575e-4 months <br />, February 1,[1982, a temporary hose connection from No. 1 Unit Spent Fuel Pool to No. 2 Unit Spent Fuel Pool Heat Exchanger developed a leak on the 84' Elevation, No. 1 Auxiliary Building, at the hose connection.

At 0927 hours0.0107 days <br />0.258 hours <br />0.00153 weeks <br />3.527235e-4 months <br /> the leak was isolated.

At 0935 hours0.0108 days <br />0.26 hours <br />0.00155 weeks <br />3.557675e-4 months <br /> the Spent Fuel Pit level was verified to be greater than 23 feet above the top of the fuel assemblies.

The volume of the spill was estimated at 23,000 gallons.

At 1600 hours0.0185 days <br />0.444 hours <br />0.00265 weeks <br />6.088e-4 months <br /> an unusual event was declared and the Emergency Procedure EPI-l was complied with.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The temporary hose leaked at the hose connection due to improper installation of the clamp.

ANALYSIS OF OCCURRENCE:

The low level radioactive water was contained by the Unit 1 Auxiliary Building, and recovered by the Plant Radioactive Liquid Waste System. Sixteen workmen had their shoes, socks, and lower trousers contaminated.

The workmen were decontaminated, and returned to work.

They received no measurable radiation exposure from the incident.

The contaminated floor area was properly decontaminated.

LER 82-10/03X-1 -

CORRECTIVE ACTION

At 1230 hours0.0142 days <br />0.342 hours <br />0.00203 weeks <br />4.68015e-4 months <br />,, the cooling flow for No. 1 Spent Fuel Pool was returned to the No. 1 Spent Fuel Pool Heat Exchanger.

The temporary hose to No. 2 Spent Fuel Pool Heat Exchanger was disconnected.

Later, it was reconnected utilizing double hose clamps and calculated torque specifications.

Safety evaluation S-1-N300-MSE-ll6 established that fuel integrity and plant safety was insured for any instance of pool drainage, loss of cooling, reactivity addition, or radiological consequences.

FAILURE DATA:

Not Applicable Prepared By F.

Dickey e [oWV General Manager -

SORC Meeting No.

82-24