05000272/LER-1982-006, Forwards LER 82-006/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 82-006/03L-0.Detailed Event Analysis Encl
ML20041A699
Person / Time
Site: Salem 
Issue date: 02/10/1982
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20041A700 List:
References
NUDOCS 8202220418
Download: ML20041A699 (3)


LER-1982-006, Forwards LER 82-006/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
2721982006R00 - NRC Website

text

-

D PSEG Public Servict Electric and Gas Company P.O. Box E Hancocks Bridge, New Jersey 08 '38 Salem Generating Station February 10, 1932 Mr.

R. C. Haynes Regional Administrator USNRC

/'

Y Region 1 f

k, 631 Park Avenue

' //

'Si,

\\

/

King of Prussia, Pennsylvania 19406

'9IE

Dear Mr. Haynes:

01

  1. 1 t$ldfp D k, A LICENSE-NO. DPR-70 ij*;

3 _.

6 DOCKET NO. 50-272 REPORTABLE OCCURRENCE 82-06/03L

/%

  • v q

-, 39 Pursuant to the requirements of Salem Generating Station ~

Unit No.

1, Technical Specifications, Section 6.9.1.9.b, we are submitting Licensee Event Report for Reportable Occurrence 82-06/03L..This report is required within thirty (30) days of the occurrence.

Sincerely yours, y

t. f. $

D H.-

J. Midura General Manager -

Salem Operations

@ FD:al CC:

Distribution The Fnornv Ponnto _

ggp s-8202220418 B20210 m m xw nai -

PDR ADOCK 05000272

/ j'

"--- J

_ _P DR __ __

Report Number:

82-06/03L Report'Date:

02-10-82 Occurrence Date:

01-13-82 Facility:

Salem Generating Station, Unit-1 Public Service Electric & Gas Company Hancocks Bridge,-New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Air Particulate Detector Pump - Inoperable.

This report was initiated by Incident Report _82-011.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 6 - Rx Power 0% - Unit Load 0 MWe DESCRIPTION OF OCCURRENCE:

On January 13, 1982 an operator discovered that the Air Particulate Detector (APD) Pump had failed.

An attempt to restart-it was un-successful.

Therefore, at 0001 hours1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, the APD Pump was declared inoperable, rendering radiation monitors 1RllA, 1R12A, and 1R12B inoperable, and Action Statements 3.3.3.1.b Action 22 and 3.9.9 were entered.

This occurrence constituted operation in a degraded mode in accordance with Technical Specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

The high speed and low speed filter paper drives had failed.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.3.3.1.b Action 22 requires:

With the number of channels operable less than required by the minimum channels operable requirement, comply with the action requirements of Specification 3.9.9.

Technical Specification 3.9.9 requires:

With the containment purge and pressure-vacuum relief isolation system inoperable, close each of the purge and pressure-vacuum relief penetrations providing direct access from the containment atmosphere to the outside atmosphere.

i I

LER-82-06/03L. 'CORhECTIVE' ACTION:

All of the required containment purge and pressure-vacuum relief penetrations were isolated.

The high speed and low speed filter paper drives were replaced and the APD-was tested satisfactorily.

At 0030 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />,-January 14, 1982,- Action Statements 3.3.3.1.b Action 22_and 3.9.9 were terminated.

FAILURE DATA:

LFE Corporation

' Filter Paper Drives Prepared By-F.

Dickey

/

D[d *W Ge'neral Manager -

Salem Operations SORC Meeting No.82-16A