ML20062E565

From kanterella
Revision as of 17:28, 24 March 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Deficiency Rept for Subj Facils:Use of non-ASME Components on Primary Containment Personnel Access Airlocks
ML20062E565
Person / Time
Site: Hartsville, Phipps Bend  Tennessee Valley Authority icon.png
Issue date: 11/02/1978
From: Gilleland J
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20062E568 List:
References
NUDOCS 7812080213
Download: ML20062E565 (1)


Text

.

TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374o1 ~

r - .

830 Power Building -

o ,

4GV i 1979 3[

Mr. James P. O'Reilly, Director f Office of Inspection and Enforcement [h ([ g U.S. Nuclear Regulatory Commission Region II - Suite 3100 } ) , y L/

101 Marietta Street $(up4/

Atlanta, Georgia 30303

Dear Mr. O'Reilly:

/

h)

[...lHARTSVILLE AND HIPPS BEND $ CLEAR PLANTS, ALL UNITS - REPORTABLE DEFICIENCY - USE . N-ASME COMPONENTS ON PRIMARY CONTAINMEhT PERSONNEL ACCESS AIRLOCKS (NCR CHT/PB-78-1)

Initial report of the subject deficiency was made to Tom Burdette, NRC-0IE, Region II, on October 6, 1978. In compliance with paragraph 50.55(e) of 10 CF" Part 50, we are enclosing the first interim report of the subject deficiency. It is anticipated that another report will be transmitted to you on or before February 15, 1979. If you have any questions on this matter, please call Tish Jenkins at FTS 854-2014.

Very truly pours, A

. )-[ .<l'YC s<h- '.

,! J. E. Gilleland f'N Assistant Manager of Power C1 _

Enclosure ,

l 9