ML20009G127

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re High Pressure Core Spray Component Wiring Discrepancies.Corrective Action Date for Hardware & Software Will Be 810730 Instead of 810630. Revised Vendor Drawings Have Not Been Received
ML20009G127
Person / Time
Site: Hartsville, Phipps Bend  
Issue date: 07/15/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, HNP-A-084, HNP-A-085, HNP-A-086, HNP-A-090, HNP-A-84, HNP-A-85, HNP-A-86, HNP-A-90, PBNP-033, PBNP-33, NUDOCS 8108030354
Download: ML20009G127 (1)


Text

.

@- T f 7 OFFICIAL COPY 400 Chestnut Street Tower IT

,f.,u>,f w\\

/ Q3

, f B.

'g July 15, 1981 e

c; p c.

11931 #'-

6 Mr. James P. O'Reilly, Director

(~

,,,.p!!joo 3..

~

Office of Inspection and Enforcement ca U.S. Nuclear Regulatory Commission S,,

7 Region II - Suite 3100

\\(xc 101 Marietta Street N9[j7 p Atlanta, Georgia 30303

Dear Mr. O'Reilly:

HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS - REPORTABLE DEFICIENCIES -

HIGH PRESSURE CORE SPRAY COMPONENT WIRING DISCREPANCIES (HNP-A-084, HNP-A-085, HNP-A-086, -HNP-A-090, AND PBNP-033)

Our report dated February 10, 1981 on these three nonconforming conditions previously identified to your office indicated that hardware and software corrections would be completed by June 30, 1981,, As discussed with Pete Taylor on July 1,.1981, TVA cannot meet this date because revised vendor drawings have not been received.

The date when corrective actions will be completed is now September 30, 1981.

If you have any questions, please call Jim Domer at FTS 857-2014.

Very truly yours, TENNESSEE VALLEY AUTHORITY l

L. M. Mills, Manager Nuclear Regulation and Safety cc:

Mr. Victor Stello, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 s.9 8108030354 810715 PDR ADOCK 05000518 s

PDR


,-.-v w

rw&-w-t

-w-

,-r-


v--

--m

. - - -. - - -