ML19347E005

From kanterella
Jump to navigation Jump to search
Forwards Response to IE Bulletin 80-23, Failures of Solenoid Valves Mfg by Valcor Engineering Corp. Valcor Valves Cited in Bulletin Are Not in Use at Plants
ML19347E005
Person / Time
Site: Hartsville, Phipps Bend  Tennessee Valley Authority icon.png
Issue date: 04/01/1981
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-80-23, NUDOCS 8104140604
Download: ML19347E005 (2)


Text

_ _ _ .

s' TENNESSEE VALLEY AUTHORITY. ; P

b

{

CHATTANOOGA, TENNESSEE 37401 400 Chestnut Street Tower II

,. tl 0 April 1, 1981 e- S Mr. James P. O'Reilly, Director g O>

(tC Office of Inspection and Enforcement . .

U.S. Nuclear Regulatory Commission ~ y Region II - Suite 3100 E Apg '

101 Marietta Street --

O ~

'II Atlanta, Georgia 30303

{ kgg/Sg 7

Dear Mr. O'Reilly:

$.* i 4'

0 0F INSPECTION AND ENFORCEMENT BULLETIN 80-23 -

0-5 -51 @ @ -553, -554 - HARTSVILLE AND PHIPPS BEND NUCLEAR P NTS In response to your November 14, 1980, letter to H. G. Parris which transmitted OIE Bulletin 80-23, we are enclosing the final report on ,

our investigations for the Hartsville and Phipps Bend Nuclear Plants If you have any questions, please call Jim Domer at FTS 857-2014.

To the best of my knowledge, I declare the statements contained herein are complete and true.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure ec: Office of Inspection and Enforcement (Enclosure)

U.S. Nuclear Regulatory Commission Division of Reactor Operations Inspection Washington, DC 20555 Sie414 An Ecual Opportunity Employer

ENCLOSURE FINAL RESPONSE TO IE BULLETIN 80-23 HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS (DOCKET NOS. STN 50-518, -519, -520 -521, -553, -554)

TVA has completed its investigation of items addressed in OIE Bulletin 80-23 and has determined that the subject Valcor solenoid

- valves having part Nos. V70900-21-1 or 3 are not used at Hartsville or Phipps Bend.

Approximately 10 man-hours were expended in the review of these facilities.

9 e

e e

9 1

l l

1