ry-OFFICIAL COPY TINNESSZZ VALLE': /-.UTH C R ;~Y d)

CH ATTANOCGA. TENN ES3EE 3740:

400 Chestnut Street Tower II b%

July 8, 1

\\

d N(L U L L Mr. James P. O'Reilly, Director LL Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission LE JUL 31981 ~

Region II - Suite 3100 101 Marietta Street C

u.s. g l3 7,

j Atlanta, Georgia 30303

.s D-('

Dear Mr. O'Reilly:

'%fff l OFFICE OF INSPECTION AND ENFORCEMENT BULLETIN 81 RII:JP0 50-518,

-519, -520, -521, -553, -554 - HARTSVILLE AND PHIPPS BEND NUCLEAR PLANTS Please reference your letter dated April 9, 1981 to H. G. Parris which transmitted OIE Bulletin 81-02 for TVA action.

This letter constitutes our first interim response to the subject bulletin.

Bulletin 81-02 requested a review of safety-related components to determine if certain models of Westinghouse-EMD and Borg-Warner-NVD, three-or four-inch valves are planned for use in plants with a construction permit.

EN DES has determined that none of'the potentially deficient valves are being supplied under,the NSSS contract for Hartsville or Phipps Bend Nuclear Plants. TVA is still investigating the applicability of this bulletin to the remainder of the valves not furnished under the NSSS contract. TVA anticipates transmitting an additional report on or before October 16, 1981.

If you have any questions, please call Jim Domer at FTS 857-2014.

To the best of my knowledge, I declare the statements contained herein are complete and true.

Very truly yours, TENNESSEE VALLEY AUTHORITY L.

M.' Mills, Manage'r Nuclear Regulation and Safety cc: Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Division of Reactor Operations Inspection i

Washington, DC 20555 sett s

IO 8107240307 810708 PDR ADOCK 05000518 G