ML20042A246

From kanterella
Revision as of 07:02, 13 March 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
LER 82-005/03L-0:on 820206,main Steam Isolation Valve Dwg 20728-B for Loop 23 Failed to Close During Isolation of Secondary Plant for Maint.Caused by Insufficient Packing Lubrication.Packing Lubricated & Valve Stroked
ML20042A246
Person / Time
Site: Indian Point Entergy icon.png
Issue date: 03/08/1982
From: Hinrichs G
CONSOLIDATED EDISON CO. OF NEW YORK, INC.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20042A238 List:
References
LER-82-005-03L, LER-82-5-3L, NUDOCS 8203230243
Download: ML20042A246 (1)


Text

.. ........

L77)

LICENSEE EVENT REPORT CONTROL BLOCK: l I

l l l l l lh e

(PLEASE PRINT OR TYPE ALL REQUIRED llVFORMATIOR) iT l I Nl Y l Il P l Sj 2 l@l C i 0l -l Cl 0 l Cl 0 l 0l -l 0l 0 25l@l264 l1 l 1 l 1l 1l@l51 GAl T Sdl@

8 9 LICENSEE CODE 14 15 LICENSE NUMdER LICENSL TYPE JO

OM'T olil $

% 1 Ll@D 15 101 01 G i 21417 l@l of 21 al 61s i 21@l7d o l ,1 el al n I ,1@ 44 d3 8 60 61 DOCK ET NU'.'8 E R td 69 EVENT O ATE HEPCRT DATE EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h TTT1 I While in the hot shutdown condition, the Main Steam Isolation valve I vl3l l (MS-1) for Looo 23 failed to c1cse daring thn procnnn nf i nni nH m I O 14 i l the secondary olant for maintenance. The valve was u.. ally closed. I y is, ; All other MSIV's closed as designed (Tech Spec. 3.4.A (5)). Previous l 0 l6 l l events R.O. 74-2-24 and LER 78-021. I Ol7ll l I

O la l l 80 89 E CODE SUSC E COMPONENT CODE SU8 COD'E

  • Ol9l l Hj B lg gg l Blg l Vl Ij LlV l ElX jQ lClg ]g '

8 9 to 1i 12 13 18 19 .O SEQUENTIAL OCCUR RE NCE REPORT REVISION LER!RO EVENT YEAR R EPORT NO. COOE TYPE N O.

@ ,at u g l a 12 I l-l 101 Ol s i I/I I 0131 I3011 1-1 Id

.,21 22 23 24 26 27 28 29 31 32 K N AC ON ON PLANT TET HOURS S8 IT FOR 8. SUPPLIE MANUFACTURER

(_B 33 jglJ4Zl@ lJ5Z l@ l36Z[@ l 0l 0 l q 0l J/ 40

@@ l Nl@ l Nl@

41 42 43 l44A l 5 l 8l 541l@

CAUSE DESCRIPTION AND CORRECTIVE ACTIONS @

[i l0 l l A 28" Atwood and Morrill Co. Valve Mark No. 28 x P 36 (DWG 20728-B) l l

ml failed to close due to insufficient lubrication of the valve packing I l

[, i y l The packing was lubricated with Nuclear Grade cocoer crachite anti- l l

isl3l l seize lubricant. The valve was stroked three times and closed each I t i i41 I time well within the recuired time limit of 5 seconds.

80 I

P 8 9 ST S  % POWER OTHER STATUS IS RY OISOOVERY OESCRIPTION I5l5l lG l @ l 0j q 0l@l NA l lAl@l Ocerator Observation l A TlVITY CO TENT RELEASED OF RELE ASE AMOUNT OF ACTIVITY LOCATION OF RELEASE l1l6l8 9J @ l Zl@ l NA l l NA l 7 10 11 44 45 80 PERSONNEL EXPOSURES NUMBER DESCRIPTION 11 l 7 l l 010 l 0l@lTYPE @lNA l l I ' ' '

PERSONNE't iNauNIES l NuuSER oESCniPriON@

!iIRII0l0Iol@l l 8 9 11 12 un 80 I

, LOSS OF OR D AVAGE TO FACll!TY ',

TUPE DESCRIPTION l

11 l 9 l P 8 9

@l10 NA 80 Pu8uCiTY e NRC USE ONLY l

l210l[__Njhl ISSUEO DESC R' e20323024392030k7 050002PDR l llllllllll((l7 PDR ADOCW P 8 9 10 6 68 69 80 3 NAME OF PREPARER Gary Hinrichs pgoys; 526-5475 2