'SSRC FORM 366 - OMLZdLOA2 RMTTRY COMMISSION

-(7 771 LICENSEE EVENT REPORT COBOL BL,0CK- c l 1

l l l l l lh 6

(PLEASE PRINT CR TYPE ALL REQUIRED INFORMATICN) 8 IM8 9I YI 11 7

PIS I 21@l n I ol-10101 LICENSEE COGE 14 15 ol o I 91 b in l@l 41LICENSE LICENSE NLMBER 2$ 26

'411TYPE 1 ll@l Jo

! l

. 57 4AT $8 @

CON'T

.!60 L hl l5 l0go l0g 2l4 l7tidgl 1l 1l 1l 1l 8 l1 gl1 l 2 l 2l 1 l 8lJ@

Q7 8 S uRC 61 DOCKET NUMBER 69 EVENT OATE 14 75 REPORT DATE

  • 80 EVENT DESCRIPTION AND PROB ABLE CONSEQUENCES h g lDURI?!G t'OICIAL OPERATION, TIIP '!O . 1 SFAL RETUPli FLOrt Ppn't 'TO , 23 Pcp l g lIt! CREASED TO GREATER THAM 5 GPM. THE AFFECTFD RCD WAS RF?tOVFD FRn?! l n y l SERVICE AMD THE UMIT WAS SHUTDOUM TO ALLOW INVESTIGATIO!I AND REPAIRS l g ;TO BE ACCOMPLISHED. NO OTHER RCPs UERE AFFECTED. l EI I fliTTII I 10181l I E CODE SUSC E COMPCNENT CODE SUSC O'E SU E O 9 l Cl El@ lE l@ l q @ l P l Ul M l Pl X l Xl@ lB l @ lZ l @ ~

7 8 9 10 11 12 13 18 19 20

,_ SEQUENTIAL OCCURRENCE REPORT REVISION EV ENT YE A R REPORT NO. CODE TYPE NO.

h RE gU LE R1RO l0l1l l--l l0 l3l 0l y l q j l Xl g l 0l

_ 28 22 23 24 26 27 23 29 JJ 31 32 N ON PLA T TET O WOURS 22 53 1 FOR' B. S *PLIE MA LFACTLRER l^

AC2N lA l@ Z@ l 0 12 l8 lm l lY l g lMl g l!T l g lMl 1l2ln g M l@l34 I I 1@ 35 ^6 37 40 44 42 43 44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS g lIMSPECTION OF THE FESTI!!GHOUSE RCP, f tODEL V 11002-Al, CO'TTROLLPD LrAEAGP ]

, , - ; SEAL REVEALPD SCORE IUmKS O!I THE SEAL RIMG A'TD A BPOKEM SEAL RU?"1FR l

, yA!!TI-ROTATION PIM. IT IS ??OT CFRTAIM MFFTHER 'mF DI?! FBILURF MAS TFP  ;

, g CAUSE OR THE EFFECT OF THE SEAL FAILURE. A ?iEM SET OF SEALS IUCLUDII'G l

, , ,A PIM OF MODIFIED DESIGM T6AS IMSTALLED. g 7 8 9 80 A  % POWER OTHER STATUS 015 0 RY DISCOVERY DESCRIPTION

,l,.5,1,5,,J b h I ll q 0l@ l MA OPERATOR OBSERVATIO'T l lAl@l l

AETiviTY COSTENT RETE ASEO cF RELEASE AMOUNT OF ACTIVITY LOCATION OF RELEASE NA NA 7

1 6 8 3 h l Zl to l

11 44 l l 45 80 l

PERSONNEL EXPOSURES NUve t a TYPF DESCRIPT?ON MAI! M: MAIMT. - 10.25, ELECT. SUPPORT = 1.43 Q l '0 *l 3 l 0 l@l El@l" l

PERSONNE L iN3u' dies NuusER DESCRtPTiONh y l 08 9l 0 l 0 lgl 7

tiA 80 l

11 12

'7P r

r 8201060324 911221" Es[RPYO b '

I PDR ADOCK 05000247 60 6 PDR NRC USE ONLY g7 g 9

@f"# iSk 30 P RELEASE TO UPI & AP OM 11/.11/81 l 68 63 lllllllll1Illh 60 2

_ _._____ _. _ _ _______ __ _ __ ____ _ 3RETMN W.WX%Sm; @86-@l70 _

o _

~

(

i  :

e O j

~

Attachment I

j c Docket No. 05000247 Consolidated Edison Co. Of N.Y., Inc.

Ler No.-81-030/99x-0 Indian Point Station, Unit 2

'During normal operation, the No. 1 seal: flow from 'i No. 23 RCP increased to greater than 5 GP:t and the thermal barrier differential pressure decreased from 70 psi to 10 psi.

The RCP was shut down and the unit brought to a shut down condition for repairs to the RCP.

The disassembly of the 23 RCP seal package revealed score marks on the seal ring and a broken seal runner anti-rotation pin. It is probable that foreign material got into the seals and caused the

-failure. The seal ring was difficult to remove during disassembly.

It is not certain whether the anti-rotation pin failure was a cause or effect of the seal failure. A new set of seals was installed.

The replacement anti-rotation pin was of the newer, modified design.

(cross-section and material change from 304ss to 17-4 ph steel).

4 Y

3 i

l-I s

r-. ' ,

. - .- -M+ (

l .

3 $.

-r 4 t'

-}