LER 83-052/03L-0:on 830411,while Reviewing Vessel Head Installation Work Package,Discovered Head Flange/Vessel Flange Thermocouples Not Physically Reinstalled During Insulation Installation.Cause Under Evaluation
ML20023D477
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 05/11/1983
From: Rohrer M
MISSISSIPPI POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20023D466 List:
References
LER-83-052-03L, LER-83-52-3L, NUDOCS 8305200532
Download: ML20023D477 (1)


Text

~ ~

NRC eoRM aos u. s. seUCLEAm REGULATORY COMME 354000 T".. LICENSEE EVENT REPORT Attachment to AECM-83/0275 Page 1 of 1 CONTROL SLOCK: l 9

l l l l l 6

lh (PLEAM PRINT OR TYM ALL RE2UIRED INFOIMATIOfel O i 7 8 9 l #4 LICENSEE SI d sI CODE d il@l oiS I ol -I ol oLICENSE 14 I d oNuMSER I ol -I d o l@l 426l 11LICENSE 2S 1 l 11 1l@l57 CAT TYPE JO I

sel@

CON'T

' 7 O i 8

l'"C'I 60Ll@l El01 $ 01 0101 4 11 6E @l DOCKET NUMDER 89 014 l 1l 11 d 3l@LolREPORT EVENT DATE 74 75 d ilDATE il 81 3l@ 80 EVENT DESCRIPTION AND PROSABLE CONSEQUENCES h O 2 lun Anril 11. 1983. while reviewina the vessel head installation work

~

I l

l O 3 loackage the 18cc Superintendent discovered that the head flance/ vessel l O 4 fflance thermocouples had not been physically reinstalled durina the 1 ITTiG linsulation installation. Consequently, for approximately a 30 day l O 6 leeriod the emerators were monitorina ambient air temmeratures. The i O 7 laurVe111ance requires verification that these temperatures are areater 1 O u Ithan cr soual to 70 decrees F in mode 4. I 7 89 80 COOE SU8C E COMPONENT CODE Sus ode SU E O 9 7 8 I Cl a l@ LD_J@ LzJ@ l zi z i zi z i zi r l@ W@ L2.J @

9 to 11 12 13 13 9 20

_ SEQUENTIAL OCCURRENCE REPORT REVISION LER RO EVENT YE AR REPORT NO. CODE TYPE N O.

@ ,ag 181 31 [-_J l oisi 21 L/_j i ol 3 1 L'_J L-J Lo_J

_ 21 22 23 24 26 27 3 a 30 38 32 K N AC N L NT HOURS SS IT FORM 8. SV L1 MANUF CTURER lG_J@L.zJ@

33 34 @5 3

L 36

_zJ @ 37l o I of o I of lY_j@

de 4i Wg 42 LZj@

43 l Z l 9l 9 l 9l@

44 47 CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h M IThe cause is still under evaluation. The flance thermocouples have beeni i i treinstalled. A follow-up report is expected to be submitted by May 30. I l i 2 11983. This is considered an interim report submittea pursuant to T.S. l l

i 3 l 6.9.1.1.3.b as the surveillance requiremerats of Technical Specification l l i 4 14.4.6.1.4 were not actually met. I 7 8 9 30 STA S  % POWER OTHER STATUS SO R JeSCOVERY DESCRIPTION E LsJ@ loIoIel@l"

m I La

_ l@l nrt Packai wie=

l

!' "JnviTY CanNT AMOuNTO,ACuviTY. @ i LOCA00N OF REuASE @

i

'i s REu' L.z_l ASE@o OP REu ASEL_z )@l m

' nRSO~~a n ,053ES "

Ie

~u,,.E R Tvn OESCRi,T,0 @

i 7 I o l o l el@L_J@l" =

I

,ERSO~~E L i~;u'R$ ES "

~uM.ER OESCRe,TiO~@

' 8 lololol@lm 7 8 9 n $2 8305200532 830511 80 1

', 5,5,0' g7,^,yg C'LITY @ PDR ADOCK 05000416 S " "

r 8 Lu@la 7 H 9 to 80 I

DE RIPTBON 2 o L ISSUUE@lm i lllll11lll111 A N 9 80 68 69 80 E

~~

0 i

NAME OF PREPARER M- V. Rnbror PHONE' "3 J