Text

4 I "Cl III' 7'/l,'I.'I",<G~// ////"7l'h",',I /l l////7/,'71]~'/", /'7 JJ~///Ilail" IIII/l2 ROCH ESTER GAS AND ELEC TRI C CORPORATION ~ 89 EAST AVENUE, ROCHESTER, N.Y. 14649 LEON D. WHITE. JR. TCLCP<04C VICC PRCSIDCNT e~cA cooc 7ie 546.2700 January 22, 1980 Mr. Boyce H. Grier, Director U. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region I 631 Park Avenue King of Prussia, Pennsylvania 19406

Subject:

LER 79-025/03L-O, Omission of testing air lock door seals R. E. Ginna Nuclear Power Plant, Unit No. 1 Docket No. 50-244

Dear Mr. Grier:

In accordance with Technical Specifications, Article 6.9.2.b(3)

(observed inadequacies in the implementation of administrative or proce-dural controls which threaten to cause reduction of degree of redundancy provided in reactor protection systems or engineered safety feature systems) the attached Licensee Event Report LER 79-025/03L-0 is hereby submitted. Two additional copies of this letter and the report are enclosed.

Attachment cc: Mr. Victor Stello, Jr. (30) gyOS Mr. Norman Hailer (3)

H