ML17250B180

From kanterella
Jump to navigation Jump to search
Responds to NRC Bulletin 90-001, Loss of Fill-Oil in Transmitters Mfg by Rosemount. Util Does Not Need to Develop Enhanced Surveillance Program to Monitor Currently Installed Transmitter Based Upon Limited Installed Quantity
ML17250B180
Person / Time
Site: Ginna 
Issue date: 05/29/1990
From: Mecredy R
ROCHESTER GAS & ELECTRIC CORP.
To: Andrea Johnson
Office of Nuclear Reactor Regulation
References
REF-PT21-90 IEB-90-001, IEB-90-1, NUDOCS 9006080228
Download: ML17250B180 (3)


Text

ACCELERATED DQTRJBUTION DEMONSTRATION SYSTEM REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9006080228 DOC.DATE: 90/05/29 NOTARIZED: YES FACIL:50-244 Robert Emmet Ginna Nuclear Plant, Unit 1, Rochester AUTH.NAME AUTHOR AFFILIATION MECREDY,R.C.

Rochester Gas 6 Electric Corp.

RECIP.NAME RECIPIENT AFFILIATION JOHNSON,A.R.

Project Directorate I-3

SUBJECT:

Responds to NRC Bulletin 90-001, "Loss of Fill-Oil in Transmitters Mfg by Rosemount."

DISTRIBUTION CODE:

IE39D COPIES RECEIVED:LTR 2 ENCL 4 SIZE:

TITLE: NRC Bulletin 90-001, Loss of Fill Oil in Transmitters Mfg NOTES:License Exp date in accordance with 10CFR2,2.109(9/19/72).

DOCKET

'G 05000244 by Rosemoun 05000244 RECIPIENT ID CODE/NAME PD1-3 LA JOHNSON,A INTERNAL: NRR LE,N NRR RAMSEY,J REC Fly@

02 G

ILE 01 COPIES LTTR ENCL RECIPIENT ID CODE/NAME PD1-3 PD NRR PERCH,R NRR/DRIS/RVIB RES FARMER,W COPIES LTTR ENCL EXTERNAL: LPDR NSIC I

pgpos (9 ~ i NRC PDR NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACT THE DOCUMENT CONTROL DESK, ROOM P 1-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

TOTAL NUMBER OF COPIES REQUIRED:

LTTR 14 ENCL

ROCHESTER GAS AND ELECTRIC CORPORATION

~ 89 EAST AVENUE. ROCHESTER, N.Y.

14649.0001 May 29, 1990 U.S. Nuclear Regulatory Commission Document Control Desk Attention:

Allen R. Johnson Project Directorate I-3 Washington, D.C.

20555

Subject:

Response

to Bulletin 90-01 Loss of Fill-Oil in Transmitters Manufactured by Rosemount R.E.

Ginna Nuclear Power Plant Docket, Number 50-244

Dear Mr. Johnson:

NRC Bulletin 90-01 requested that licensees promptly 'identify and take appropriate corrective actions for Model

1153, Series B;

Model 1153, Series D; and Model 1154 transmitters manufactured by Rosemount that may be leaking fill-oil.

This letter provides the response required by NRC Bulletin 90-01.

Rochester Gas and Electric, in accordance with requested Action Item 1, confirms that the R.E.

Ginna Nuclear Power Plant does not have any Rosemount transmitters installed in either safety-related systems or systems installed in accordance with 10CFR50.62 (ATWS Rule).

Requested Action Items 2, 3, 4, and 5 are, therefore, not applicable.

tions, (nine Model 1151) and (two Model 1153D),

have not exhibited symptoms indicative of loss of fill-oil.

Rochester Gas and Electric does not need to develop an enhanced surveillance program to monitor currently installed Rosemount transmitters based upon the limited installed quantity (11), the low differential pressure and the non-safety related applications.

gr ep22:'app,,2'+

PDR ADOCK p~ip(ip244 C<

PDC

( ygzg68'4f

Page 2

NRC Bulletin 90-01 May 29, 1990 Very truly yours, Robert C.

ecr y

Division Manager Nuclear Production Subscribed and Sworn before me on this

- 'ay, of xc'otary Pubbc rrr the Strrte ol New York MONROECOVNTY Cororohsioo Expires Nov. 30, 19.~

U.S. Nuclear Regulatory Commission Region 1

475 Allendale Road King of Prussia, PA 19406 NRC Senior Resident Inspector Ginna Station