Initial Approach to Power Tests (B-Series),Interim Startup Rept 13 for 790823-1122
ML19211A955
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 11/22/1979
From:
PUBLIC SERVICE CO. OF COLORADO
To:
Shared Package
ML19211A954 List:
References
NUDOCS 7912210376
Download: ML19211A955 (2)


Text

...THE FORT ST. VRAIN INITIAL APPROACH TO POWER TESTS (B-SERIES)

.INTERIM REPORT 13 Report for Period Ending November 22, 1979 1637 123 7912210 3 76 .,.Inr.erim Report 8 covering the 90 day period ending August 22, 1978, re-ported the completion of all tests up to 70% of plant load. Since the Nuclear Regulatory Commission did not release the plant for operation at power levels in excess of 70%, no further Initial Approach to Power Tests were performed during the 90 days ending Novecher 22, 1979.

The Fort S t.

Vrain Nuclear Generating Station was accepted for commercial operation at 70% power by Public Service Company of Colorado on July 1,1979.

Future interim reports will report the results of any startup tests at power levels above 70%.

.

..-.'GE FORT ST. VPE N INITIAL APPROACH TO POWER TESTS (B-SERIES)

.INTERIM REPORT 13 Report for Period Ending November 22, 1979

, s 9 1637 125 ,.A Interim Report 8 covering the 90 day period ending August 22, 1978, re-ported the completion of all tests up to 70% of plant load.

Since the Nuclear Regulatory Commission did not release the plant for operation at power levels in excess of 70%, no further Initial Approach to Power Tests were performed during the 90 days ending November 22, 1979.

The Fort St. Vrain Nuclear Generating Station was accepted for commercial operation at 70% power by Public Service Company of Colorado on July 1,1979.

Future interim reports will report the results of any startup tests at power levels above 70%.

.%1637 126