'J l

l THE FORT ST. VRAIN INITIAL APPROACH TO POWER (B-SERIES)

INTERIM REPORT 44 Report For Period Ending August 13, 1987

~J T

lo SF R88ea 8?88$g7

,Y P

\\\\

e

., > +

'e Interim Report 21 covering the 90-day period from August 23, 1981, to November 22, 1981, reported the completion of the majority of tests at 100% of plant load.

Significant power levels or appropriate plant conditions required for remaining tests have not been achieved since then. During the period covered by this report, the reactor was taken critical on April 17, 1987.

The reactor is currently limited to 82% power by the Nuclear Regulatory Commission.

No further initial approach to power tests were performed during the 90-day period ending August 13, 1987.

Further interim reports will report the results of any startup tests which will remain in the "open" status.

E

O rubiic service-

=: <= -

16805 WCR 19 1/2, Platteville, Colorado 80651 September 14, 1987 Fort St. Vrain l'

Unit No. 1 P-87312 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk e

Washington, D.C.

20555 Docket No. 50-267

SUBJECT:

STARTUP REPORT #44 FOR FORT ST. VRAIN NUCLEAR GENERATING STATION, UNIT NO. 1

REFERENCE:

Facility Operating License Number DPR-34

Dear Sir:

Enclosed, please find a copy of the torty-fourth Startup Report for Fort St. Vrain Nuclear Generating Station, Unit No. 1.

This report covers the period from May 16, 1987, through August 13, 1987. This report is being submitted i t, fulfillment of the requirements of Section 7.5.la of the Fort St. Vrain Technical Specifications.

If you have any questions, please contact Mr.

M. H. Holmes at (303) 480-6960.

Sincerely, r ggg p

& /Ll RMd5'Adm SEP 211987 I

R. O. Williams, Jr.

Vice President j

Nuclear Operations Enclosure I

cc: Regional Administrator, Region IV ATTN: Mr. J. E. Gagliardo, Chief Reactor Projects Branch l

Mr. Robert Farrell l

Sen'or Resident Inspector Fort St. Vrain ROW:djm

' M-ML

~