Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Issue dateTitleTopic
ML20056C96623 July 1993Notice of Violation from Insp on 930614-18.Violation Noted: Licensee Failed to Follow Commitment in TS in Performance of Reload Fuel Analysis for Cycle 5
ML20056C96719 July 1993Insp Rept 50-458/93-17 on 930614-18.Violations Noted.Major Areas inspected:10CFR50.59 Safety Evaluation ProgramUltimate heat sink
Offsite Dose Calculation Manual
Temporary Modification
Process Control Program
ML20056D8143 August 1993Insp Rept 50-458/93-21 on 930621-0716.No Violations Noted. Major Areas Inspected:Licensee self-assessment Capability, Licensee Feedback of Operational Experience Info & Followup on Previous Insp ItemsCommercial Grade Dedication
ML20056G79331 August 1993Notice of Violation from Insp on 930726-30.Violation Noted: Four Zones Defeated During Testing of Protected Area Detection Sys
ML20056G79630 August 1993Partially Withheld Insp Rept 50-458/93-24 on 930726-30 (Ref 10CFR73.21).Violation Noted.Major Areas Inspected: Licensee Physical Security Program Including Records & Repts
ML20057C89724 September 1993Insp Rept 50-458/93-23 on 930718-0821.Violations Noted. Major Areas Inspected:Plant Status,Onsite Response to Events,Operational Safety Verification,Hurricane Preparedness & Maint & Surveillance Observations
ML20058A54617 October 1990Insp Rept 50-458/90-23 on 900910-14.No Violations or Deviations Noted.Major Areas Inspected:Engineering Evaluation in Response to NRC Bulletin 88-004,action of Previously Identified Items & Review of Root Cause Analysis
ML20058J8439 November 1993Errata to Notice of Violation from Insp on 930822-0925, Reflecting Editorial Changes Made to Violations
ML20058P7499 August 1990Notice of Violation from Insp on 891023-27 & 1113-17. Violations Noted:Nuclear Licensing Failed to Take Actions Necessary to Assure Timely Response for 76 Examples of Regulatory Correspondence Classified Response RequiredCondition Adverse to Quality
ML20059D64728 August 1990Insp Rept 50-458/90-15 on 900611-15.No Violations or Deviations Noted.Major Areas Inspected:Operational Status of Emergency Preparedness Program,Including Followup to Previous Insp Findings & Equipment
ML20059F4417 January 1994Insp Rept 50-458/93-25 on 931025-1112.No Violations Noted. Major Areas Inspected:Operations,Maintenance,Mgt Oversight, Surveillance & Testing,Safety Assessment & Engineering & Technical SupportCoatings
Temporary Modification
Emergency Lighting
ML20059G99820 January 1994Notice of Violation from Insp on 931107-1218.Violation Noted:Maint That Affected Performance of safety-related Equipment Was Not Performed in Accordance W/Written ProceduresEnforcement Discretion
ML20059K4739 November 1993Notice of Violation from Insp on 930822-0925.Violation Noted:Mcr Radiation Monitoring Panel RM-11 safety-related Annuciators Did Not Have Alarm Response Procedure
ML20059K4904 November 1993Insp Rept 50-458/93-26 on 930822-0925.Violations Noted.Major Areas Inspected:Plant Status,Onsited Response to Events, Operation Safety Verification,Employee Concerns Program, Maintenance & Surveillance ObservationsSafe Shutdown
Grab sample
Enforcement Discretion
Continuous fire watch
ML20125A8365 June 1985Notice of Deviation from Insp on 850225-0503
ML20125D30210 December 1992Notice of Violation from Insp on 920927-1107.Violation Noted:Both Trains of Standby Gas Treatment Not Operable When Standby Gas Treatment Was in Containment Purge Mode
ML20125D3368 December 1992Insp Rept 50-458/92-32 on 920927-1107.Violations Noted. Major Areas Inspected:Operational Safety Verification, Maint & Surveillance Observations & Review of Complex Surveillance TestEnforcement Discretion
Weak link
ML20126B5546 June 1985Insp Rept 50-458/85-35 on 850429-0503.No Violation or Deviation Identified.Major Areas Inspected:Tech Specs & Implementing Procedures.Tech Spec Review Data Sheets Encl
ML20126F69421 December 1992EN-92-101:on 921228,notice of Proposed Imposition of Civil Penalty in Amount of $100,000 Issued to Licensee.Action Based on Violations in Which Radiation Surveys Were Not Performed as Required
ML20126G16028 December 1992Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $100,000.Noncompliance Noted:Licensee Did Not Make Adequate Surveys to Assure That Individauls Were Exposed to Airborne Concentrations Exceeding in 10CFR20.103High Radiation Area
ML20127C9898 January 1993Notice of Violation from Insp on 921108-1219.Violation Noted:On 921125,licensee Entered Specified Condition When LCO Not Met,In That Reactor Pressure Increased to Greater than 150 Psig W/Rcics Inoperable
ML20127C9978 January 1993Insp Rept 50-458/92-34 on 921108-1219.Violations Noted.Major Areas Inspected:Onsite Response to Events,Operational Safety Verification,Maintenance & Surveillance Observations,Open Item Followup & Onsite Review of LERReactor Vessel Water Level
Condition Adverse to Quality
ML20127D41810 September 1992Notice of Violation from Insp on 920705-0815.Violation Noted:Licensee Testing of Safety Relief Valve Accumulator Check Valves Did Not Verify That Disk Traveled to Seat Promptly
ML20128G7997 October 1996Notice of Violation from Insp on 960811-0921.Violation Noted:Procedure RSP-0203 Was Not Properly Implemented in That Individual Entered Radiologically Controlled Area W/Out Functional Direct Reading Dosimeter
ML20128G8807 October 1996Insp Rept 50-458/96-14 on 960811-0921.Violations Noted.Major Areas Inspected:Operations,Maint,Engineering & Plant SupportMissed surveillance
Foreign Material Exclusion
ML20128N05229 May 1985Notice of Violation from Insp on 850301-0430
ML20128N07224 May 1985Insp Rept 50-458/85-23 on 850301-0430.Violation Noted: Failure to Monitor Temp During HVAC Leak Testing,To Calibr Test Instrument in Range of Use & to Stamp Procedure for Notification of QATemporary Modification
Battery sizing
ML20128N27928 May 1985Notice of Violation from Insp on 850415-19 & 29-0503
ML20128N49011 October 1996Notice of Violation from Insp on 960506-21.Violation Noted: on 960214,while in Mode 1,instrument & Control Technicians Found Valve A4-B21*N094E Closed When Valve Should Have Been Open,Which Rendered Drywell Pressure Transmitter Inoperable
ML20128P28028 May 1985Insp Rept 50-458/85-40 on 850415-19 & 29-0503.Violations Noted:Failure of High Strength Steel Bolts & Failure to Maintain Records & Furnish Evidence of Activities Affecting Quality
ML20128P69215 April 1991Notice of Violation from Insp on 910225-26.Violation Noted:Inspectors Observed on 910225,insufficient Numbers of Trained Security Officers on Second Shift to Meet Contingency Plan & Procedural Commitments
ML20129D3395 July 1985Notice of Violation from Insp on 850415-0627.Results of General Clearances on 850612 Insp Rept P5400381 Changed on 850613 from Not Applicable to Satisfactory by Reviewer Who Had Not Performed Insp.Response Requested in 30 Days
ML20129J56219 July 1985Notice of Violation from Insp on 850603-07
ML20129J56717 July 1985Insp Rept 50-458/85-42 on 850603-07.Violation Noted:Failure to Tag Lifted Leads in Panel 821 in Main Control Room
ML20133B8381 August 1985Notice of Violation from Insp on 850617-21
ML20133B8512 August 1985Notice of Violation from Insp on 850403-08
ML20133B8631 August 1985Insp Rept 50-458/85-31 on 850403-08.Violation Noted:Failure to Provide Adequate Procedure to Conduct Integrated Leak Rate Test
ML20133B8881 August 1985Insp Rept 50-458/85-49 on 850617-21.Violation Noted:Failure to Perform Adequate Review of Preoperational Test Results for CRD Hydraulic Sys
ML20133B9091 August 1985Insp Rept 50-458/85-43 on 850501-0615.Violation Noted: Failure to Obtain NRC Approval of QA Program ChangeHydrostatic
Scram Discharge Volume
ML20133F1627 January 1997Notice of Violation from Insp on 961103-1214.Violation Noted:Procedure SOP-0040, Hydrogen Mixing,Purge,Recombiners & Igniters, Rev 9,was Not Properly Maintained
ML20133F1737 January 1997Insp Rept 50-458/96-16 on 961103-1214.Violations Noted.Major Areas Inspected:Licensee Operations,Maint,Engineering & Plant SupportUnanalyzed Condition
High Radiation Area
Locked High Radiation Area
ML20133L7969 October 1985Insp Rept 50-458/85-62 on 850816-0915.Violation Noted: Administrative Procedure ADM-003 Requirements Not Fully Implemented for Surveillance Test Procedures for Semiannual Calibr of Source Range Monitor Channels A,B,C & D
ML20134G4547 November 1996Notice of Violation from Insp on 960729-0827.Violations Noted:Licensee Failed to Perform SR 3.8.4.8 within 18 Month Required Frequency
ML20134H1488 November 1996Notice of Violation from Insp on 960826-30 & 0909-13. Violation Noted:From 950331 Until 960912,design Basis for Operation of SSW CT Fans Was Not Correctly Translated Into ARP ARP-870-55, P870-55 Alarm Response
ML20135A46320 February 1997Notice of Violation from Insp on 961215-970201.Violation Noted:Activities Affecting Quality Were Not Accomplished IAW Instructions in That All Gaps in Floor Were Not Covered During Work to Preclude Dropping Intems in SSW
ML20135A46820 February 1997Insp Rept 50-458/96-17 on 961215-970201.Violations Noted. Major Areas Inspected:Operations,Maint,Engineering & Plant SupportLoop seal
Missed surveillance
ML20135B5752 December 1996Notice of Violation from Insp on 960922-1102.Violation Noted:Listed Instances Where Written Procedures Not Properly Implemented
ML20135H78212 September 1985Exam Rept 50-458/OL-85-03 on 850729.Exam Results:Two of Five Reactor Operator Candidates & 9 of 12 Senior Reactor Operator Candidates Passed ExamsReactor Vessel Water Level
Half scram
Slow transfer
Overtravel
ML20136E48830 December 1985Insp Rept 50-458/85-67 on 850923.Violations Noted:Failure to Provide Proper Escort,Failure to Control Badge/Key Cards & Failure to Make Timely Notification.Details Withheld (Ref 10CFR73.21)
ML20136G5015 November 1985Notice of Violation from Insp on 851007-11