Special Rept SR-86-002-00:on 860423,wide Range Gas Monitor Declared Inoperable.Caused by Broken Resistance Wire within General Atomic Sample Velocity Probe.Alternate Monitoring Procedure EP-2-050 Established.Probe Replaced
ML20155J577
Person / Time
Site: Waterford Entergy icon.png
Issue date: 05/12/1986
From: Barkhurst R
LOUISIANA POWER & LIGHT CO.
To: Martin R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SR-86-002-00, SR-86-2, W3A86-0047, W3A86-47, NUDOCS 8605270024
Download: ML20155J577 (3)