ML17214A572

From kanterella
Revision as of 18:31, 7 July 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Engineering Evaluation of Instrumentation Sys for Reg Guide 1.97,Rev 3.
ML17214A572
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 11/20/1983
From:
FLORIDA POWER & LIGHT CO.
To:
Shared Package
ML17214A571 List:
References
RTR-REGGD-01.097, RTR-REGGD-1.097 NUDOCS 8312050353
Download: ML17214A572 (86)


Text

ST.LUCIE PLANT UNIT NO.2.ENGINEERING EVALUATION OF INSTRUMENTATION S YSTEM FOR REGULATORY GUIDE 1.97, REV.3 DATE: November 1983 8312050353 831130 PDR ADOCK 05000389 A PDR TABLE OP CONTENTS SECTION III.IV.V.VI.VII.VIII.DESCRIPTION Regulatory Guide 1.97, Rev.3 Requirements Evaluation Criteria Methodology of Equipment Evaluation Type A Variable List of Parameters Parameter Listing Summary Sheets List of Systems Requiring Additions, Modifications or Analysis References Conclusions PAGE NO.2g 3 4,5

SECTION I REGULATORY GUIDE 1.9?, REV.3 REQUIREMENTS Regulatory Guide 1.97, Rev.3, titled"Instrumentation for Light-Water-Cooled Nuclear Power Plants to Assess Plant and Environs Conditions During and Following an Accident", divides all instrumentation used for Post Accident Monitoring into five functional types as shown below: Type A Variables:

those variables to be monitored that provide the primary information required to permit the control room operator to take specific manually controlled actions for which no automatic control is provided and that are required for safety systems to accomplish their safety function for design basis accident events.Primary information is information that is essential for the direct accomplishment of the specified safety functions; it does not include those variables that are associated with contingency actions that may also be identified in written procedures.

Type B Variables:

those variables that provide information to indicate whether plant safety functions are being accomplished, Plant safety functions are (1)reactivity control, (2)core cooling, (3)maintaining reactor coolant system integrity, and (4)maintaining containment integrity (including radioactive effluent control).Type C Variables:

those variables that provide information to indicate the potential for being breached or the actual breach of the barriers to fission product releases.The barriers are (1)fuel cladding, (2)primary coolant pressure boundary, and (3)containment.

Type D Variables:

those variables that provide information to indicate the operation of individual safety systems and other systems important to safety.These variables are to help the operator make appropriate decisions in using the individual systems important to safety in mitigating the consequences of an accident..Type E Variables:

those variables to be monitored as required for use in determining the magnitude of the release of radioactive materials and'ontinually assessing such releases.Post Accident Monitoring Instrumentation is divided into three categories based on the degree of equipment qualification requirements, redundancy, power sources, channel availability, quality assurance, and display and recording requirements.

In general, Category 1 provides for fuD qualification, redundancy, and continuous real-time display and requires onwite (standby)power.Category 2 provides for qualification but is less stringent in that it does not (of itself)include seismic qualification, redundancy, or continuous display and requires only a high-reliability power source (not necessarily standby power).Category 3 is the least stringent.

It provides for high~uality commercial grade equipment that requires only offsite power.

SECTION II EVALUATION CRITERIA Our review of RG 1.97, Rev.3 requirements applicable to operating plants shows that the requirements of this guide cover the requirements of 10 CFR 50.49 and NUREG 0737 and its subsequent clarification and generic letter 82-33.The following is the evaluation criteria used in this report for the three different categories as defined in the Regualtory Guide 1.97, Rev.3, Table l.1.ENVIRONMENTAL UALIFICATION CRITERIA a.Cate o 1 Instrumentation (a).Instrumentation located in harsh environment should comply with 10 CFR 50.49 requirements and NUREG 0588'Category 1 (IEEE-323, 1974).(b).Instrumentation located in mild environments do not have to be upgraded if they withstand their service location conditions under normal and emergency conditions., b.Cate or 2 Instrumentation (a).(b).For safety related instrumentation, follow the same criteria used for category 1 instrumentation.

Non-nuclear safety related instrumentation located in harsh environment has to be qualified per NUREG 0588 category 1.(c).Instrumentation located in mild environment should follow the same criteria used for category 1 instrumentation.

c.Cate or 3 Instrumentation Non-nuclear safety related instrumentation has to withstand its service location conditions.

2.SEISMIC UALIFICATION CRITERIA Category 1 and Safety Related Category 2 instrumentation:

The equipment shall comply with IEEE-344, 1975.(Reg.Guide 1.100)Category 3 and non safety related related category 2 instrumentation:

No specific provision required.3.REDUNDANCE Only category 1 instrumentation should be provided with redundant or diverse channels, electrically independent, and physically separated from each other, and from nonwafety equipment,'in accordance with Reg.Guide , 1.75"Physical independence of electric systems", up to and including any isolation device.Category 2 and 3 instrumentation do not require redundancy.

0 4.POWER SOURCES a.~Cate o 1'nstrumentation to be supplied from 120 VAC uninterruptible power source, or from 120 VAC Offsite Power supply, backed up by an Emergency Diesel Generator if momentary interruption of power is acceptable.

b.~Cate or 2 Instrumentation to be supplied from high reliability power source which can be either from: 1.2.3.4, 120 VAC uninterruptible, or 120 VAC Offsite Power backed by an Emergency Diesel Generator, or 125 VDC safety-related battery, or 125 VDC nonwafety related battery e.~Cate or 3 No specific provisions required.5.UALITY ASSURANCE-Qualified equipment (category 1 and safety related category 2 should comply with the Regulatory Guides listed in Table 1 of Reg.Guide 1.97 Rev.3.6.DISPLAY AND RECORDING Category 1 Instrumentation should be displayed on a real-time display.The indicator may be on a dial, digital display, CRT or strip chart recorder.Recording of instrumentation readout should be provided for at least one redundant channeL Where dedicated strip chart recorder is not provided, recording will be accomplished in the SAS computer where it will be stored on magnetic tape and saved for 14 days.This data can be retrieved and analyzed for that period.Category 2 Instrumentation should be displayed on an individual instrument or it may be processed for display on demand.Signal from effluent radioactivity and area monitors should be recorded.Category 3 Instrumentation.(Same as Category 2).Signal from effluent radioactivity, area and meteorology monitors should be recorded.r SECTION III METHODOLOGY OF EQUIPMENT EVALUATION We have evaluated existing system arrangements and identified components for variables Types A thru Z and their conformance to Reg.Guide 1.97, Rev.3 requirements applicable to existing plant.Based on our interpretation of Reg.Guide 1.97, Rev.3 all Post Accident Monitoring instrumentation can be divided into two groups as shown below: 1.ORIGINAL SAFETY RELATED INSTRUMENTATION The original safety related instrumentation located in harsh environment generally comply with 10 CFR 50.49 and NUREG 0588 Category 1 (IEEE-323, 1974).The instruments located in mild environment do not require specific qualification until revision of the Regulatory Guide 1.89 is published.

The original safety related instrumentation should comply with Reg.Guide 1.100 (IEEE-344, 1975).2.NON SAFETY INSTRUMENTATION These instruments are high quality commercial grade equipment that require no specific qualification, however if the instrument is category 2 located in harsh environment, should be environmentally qualified.

Once the evaluation of all the instrumentation has been completed, a schedule for the implementation of the required modification to comply with the Reg.Guide requirements has been included.,Section V of this report is the Parameter Listing Summary Sheets which includes all the plant instrumentation by tag numbers, grouped in the same order as the Reg.Guide 1.97, by type and categories.

The listing summarizes all the required information to perform the evalution and the results of the evaluation are shown on the column justification/schedule.

If this column is blank, it means that the instrument complies with the requirements of the Reg.Guide 1.97.The Parameter Listing Summmary Sheets provide the following information:

Item, tag number, variable description, type and category, instrument existing and required ranges, Q.A.requirements, environmental and seismic qualification, redundance, power supply, display location, schedule for implementation or justifications.

Variable description column, described the variable as listed in the Reg.Guide 1.97, Rev.3.

~~The tag number column, lists all the sensors, indicators, displays and recorders associated with variable described.

In the column-"Display Locations, Control Room C.R.", Yes, means that the indicator is located in the control room;SAS/SPDS means that the data is available in SAS/SPDS.In the Column"Display Location TSC and EOF", Yes, means that the data is available on the computer display in the TSC and EOF.Finally, section VI, lists all systems requiring modification, additions or analysis to comply with the Regulatory requirements.

SECTION IV TYPE A VARIABLE LIST OF PARAMETERS The type A variable list of.parameters, the basis for which is given in Reg.1.97, Rev.3, was established.

The following Emergency Operational Procedures (EOPS)wer e reviewed: F a.Main Steam Line Break b.Loss of Reactor Coolant c.Loss of Feedwater or Steam Generator Level d.Steam Generator Tube Leak/Failure As a result of these reviews the following parameters were designated as Type A variables:

l.2.3.4, 5.Pressurizer Pressure RCS Hot Leg Temperature RCS Cold Leg Temperature Steam Generator Level Narrow Range Containment Hydrogen Concentration SECTION V PARAMETER LISTING

SUMMARY

SHEETS FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY E 1.97 REV 3"PARA Y SHEET" TYP IABLFS'cFR 7'4, 1483 I ITEMI TAG NO.Al IPT-1107 I I I PT-1108 I I Izcc IMsplay A I Ilcc IDisplay B I IPI-1107-1 I I I PI-1108-1 I I I PR-1108/I LR-1110Z I Preesurizerl I Pressure 0 to 3000 psia IPlant ISpecific I comply Note 9 Note 9 Note 11 Note ll Note 18 Note 13 Note 18 Note 11 Note 18 Note ll Note 18 Note 11 Note l8 Note ll VARIABLE INSTRUHENT RANCE Oh I CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC IDESCRIPTION ITYPE I GORY I IRISTING REQUIRED I MENT IQUALIFICATION IOUALIFICATION I Fv-lion I I I PT-1107 I I I Tr.r.I Display B I I rcc I Displav A I I FT-1108-1 I I I PI-1107-1 I uote F ISD I INote 2 Ich I Imote 1 ISA I INote 1 ISB I INote 7 ISB I INote 7 lcA I INote>ISA I I I FOWFR.I I RFDUNDANCEI S1TPPLVI veal veal cAS HFnc HAS cpng Ves Yes~Ves Yee I veal I I I I I-I I I-I I I-I I I I I I I veal DTHFTAY LorhvTDN I gram.F I vsr FDFI THSVTFTrhvTou A2 TE-1112CB I RCS Cold I Leg Water Temp (Loop 2A1)Izcc IDisplay B I I TE-1112CA I RCS Cold Leg Water Temp (Loop 2A2)Zcc Display A ITR-1112CA/I Hh I I TE-1122CA I RCS Cold I Leg Water IICC I Temp IMsplay h l(Loop 281)I TE-1122CB I RCS Cold I Leg Water IICC I Temp IDisplay B l(Loop 282)I YR-1 122CB/I HB I I 1 I 50 F to IPlant I 750'F ISpecific I Comply 1 50'F to IPlant I 750'F ISpecific Comply 1 I 50'F to Iplant I 750'F ISpecific Comply 1 I 50'F to IPlant I Comply I 750'F ISpecific Note 1O Note 18 Note lO Note 18 Note 18 Note 10 Note 18 Note 10 Note 18 Note 18 Note ll Note 11 Note 31 Note 11 Note ll Note ll Note ll Note ll Note 11 Note ll I TF;1112CA I I zcr.I nisplav A I I'TF.-1 112m I I ZCC I Display B I I I" I I TF-)12ors I I Trr.I Display B I I TE-1122CA I I zcr.I Displav A INote I IMD INote 1 Icn I INote 1 I MA Imote 1 ISA I INote 1 Ich I l>ote 1 IMA INote 1 ISA I INote 1 I Nn INote 1 I ISD I I I>ote 1, I ISB I I SAS Song Yee SAS SFDS Ves Vee SAS gcpnS Ves SAS cpnc Yes'Yes vesI I-I I I ves I I-I I I-I I I veal I-I I I ves I I-I I I-I I I Yes I Justified for I Tntar4m nner-lation fnefer itn F>F~ePapo I$34.1 Huh@i t-VesIted with linrpnSn.44 IF4ninnent Ir.let).ITF.-111orA anR-ITE-1177m are I racorde~.I veal I I I I vesI I-I I I--t I I 1 C'\4M FLORIDA POWER AND LIGHT ST LUCIE UNIT NO 2 REGULATORY 1 97 REV 3"PARAMET Y SHEFT" TYPE A V (Continued)

N 23, loRS ITEM TAG NO VARIABLE INSTRUMENT RANGE Oh GATE-I I REOUIRE-tENvIRONMENTAL I sEIsMIc I DESCRIPTION ITYPE I GORY I EXISTING I UIRED I MENT IQUALIPICATION lOUALIFICATION I I PowER I DIsPLAv LrxavrnN I scnFDTIT.v/

REDUNDANCRI SUFPLYI CR Tgr.FnF I JIIsrTFTrATTnN A3 ITE-1112HA I I ITE-1112MB Icc Display A IRCS Hot Leg I IWater Temp I (Loop 2A)I I I I I IICC IDisplay B I I TR-1112CA/

I I HA(I I ITE-1122HA IRCS Hot Leg I (Water Temp I (Loop 2B)TE-1122HB I Icc Display A Icc Display B I I I TR-1122CB/

I HB I LT-9013D ILIC-9013A I I I I LIC&013B I I A4 ILT-9013A Steam I Generator I ILevel 2A1 I LT&013B I (Narrow IRange)LT-9013C 50'F to I 750 F I Plant I Comply Specific I Plant I Comply Specific 50'P to I 750 P I 0 to 100XI 1 I 0 to 183 IPlant l Comply I Inches I Specific I wc Note 10 Note 30 Note 18 Note 18 Note 18 Note 10 Note 10 Note 18 Note 18 Note 18 Note 9 Note 9 Note 9 Note 9 Note 18 Note 18 Note ll Note 11 Note ll Note ll Note 11 Note ll Note 11 Note 31 Note ll Note 11 Note 11 I Note ll Note 11 Note ll Note 11 Note'Il I TE-1112HR I I TF-I 1 l1NA I I I ICC I nisplav n I I Tcc I Display A I I I I I TF.-112>HR I I I TE-1122HA I I I Tr.r.I Display R I I ICc I Display A I LT-9013D T,v-9n13r.

LT-90138 Lv-9013A LIC-901~D T,Tr;9013r INote l IMA I Iwnte l IMR I INote 1 ISA I INote l (SR I INote 1 I SA I (Note l IMA I INote 1 INR I Iwote l ISA I INote 1)SR I INote I tSR I INote 1 l>h I INote l (MR I INote 1 IMr.I INote l IMD I INote I IMA I!Note l IMR I SAS spns SAS RPDS SAS SPns Yes Yes ves Yes Yes SAS SPDS SAR SPDS SAS SPng HAS SPDS*Yes Vos Veal Veal I I I I vesl vosl I I I I--I--I I I I I I I I I I-I-I I I I veaI vosl I I I I Yesl YesI I I I I-I-I I I I I-I-I I I I I I-I I I I Veal Yesl I I I I I I I veal veal I I I I I I I Veal VesI I I I I I I I<esl vosl I I I I I I-I-I I I I I I--I--I I I I I I.Tustl FleiI fnr Tntorln npora-tlon Tne<er tn Fn>ac'kaso ted wltIi lnrFRSn.4o

>qu(pm>nt T.istl.'rI'-'l 111RA aniI VF.-11110m are rocnMo8.1SBAM FLORIDA PONER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY 1.97 REV 3"PARAMET RY SHEET" TYPE A VARI (Continuerl)

N R P3, lnR3 ITEMI TAG NO.I DESCRIPTION ITYPE GORY I EXISTING I REQUIRED I MENT I UALIFICATION IOUALIFICATION I VARIABLE INSTRUMENT RANGE Oh I CATE-I I REQUIRE-I ENVIRONMENTAL I SFISMIC I PONER REDUNDANGE I s<TPPLY I F.opl vsr.I nispT>v LochvTnw I SrNPnnT.EI TUSTTFTCATTON ILIC&013C I I ILIC-9013D I I IIR-9013D/

ILR<023D I ILT&023A I I I LT&023B I I I LT<023C I I I LT&023D I I ILIC&023A'I I ILIC 9023B I.I ILIC&023C I I I LIC&023D LR-9013D/IR-9023D ISteam IGenerator ILevel 2Al l(Narrow IRange)I I I I ISteam IGenerator ILevel 281 I(Narrow IRange)I A 1 IO to 100X IPlant I Comply ISpecific 1 I 0 to 183 IPlant I Comply I Inches ISpecific I NC I 0 to 100XI Note lg Note l8 Note 18 Note 9 Note o Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 Note 18 I Note 11 I I I Note ll Note 11 Note ll Note 31 Note ll I I Note,ll Note 11 I I Note 11 Note 11 Note 11 Note'll T.rr.-on>Bs T TC-9013A Iwote 1 I Vcr I Iwote 1 I lwote 1 IMn I INote 1 LT-9023D I INote 1 LT-90230 IMC I lwote 1 INn I INote 1 l>A I l>ote 1 IMB I INote 1 IMC I lÃote T IMD I INote 1'IMn I LT-9023A LIC-9023D T,Tr;nnnr.

LIC-90238 LTr.-9npsh IMA I I I LT-90p3r.INote I I IMB I Vefi Ves ves SAS spns SAR spns SAS spns SAS spns Yes ves Ves ves Yes I I-I I I-I I I ves I I I ves I I I Yes I I I ves I I I-I I I-I I I-l I I-I I I-I I I veal I I vpsl I I I I veal I I I ves 1 I I-I I I-I-I I I-I I I-I I 1 S34'M F LORIDA PORE AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"P TYPE A VAR 1.97 REV 3 Y SHEET" (Continued)

Nn~pR v~, 1on~VARIABLE INSTRUMENT RANGE 5IA ITEM TAG NO.IDESCRIPTION ITYPE GORY I EIISTING I UIRED I MENT IQUALIPICATION IOUALIFICATION I PGNER I DIspLAY LocATIoN I scNRDULRI I REDUNDANGEI sUPPLYI GR Tsr.ROFI JUBTTPTrAvrnN A5 IHydrogen I I Sampling I land I I Analyzer I I Cubicle I l(Unit 2A)I I IHydrogen I Sampling land IAnalyzer I I Cubicle l(Unit 28)I I IHydrogen IAnalyzer IIndicatingl land I IRecording I Cubicle Sh Hydrogen I Analyzer I Indicating l and Recording Cubicle SB Contain-ment Hydrogen Concen-tration 1 I 0 to 10K IPlant I I (Capable ISpecific I of Oper-I I ating I from-5 I psig to I 44 psig)I Comply Note 18 Note 18 Note 18 Note 18 Note 11 Note ll Note 11 Note ll Il'ydropen I Samplinp land I Analyzer I Cubic1e 1(Unit 2R)I IHydrogen Igampl5np land IAnalvzer I Cubicl e I (lbt5.t 7A>I INVdronen I Analyzer I ind teat 5 np land IRecordlnp Irublcle ISB I Ipydrogen I Analyzer ITndicating land IRecordine ICubicle Ish I INote P I ISA l I I I I I I I I I INote 2 I isa I I I I I I,I I I I I l<ote p I ISA I I I I I I I I I I I I I INote 2 I ISB I I I I I I I I I I SAS I Yes l veal Sang I I l I I I I I I I~I I I I I I.I SAS I vesl Yesl spns I I I I I 1 I I l I I I I I I I I ves I-I-I I I I I I I I I'I I I I I I I I I Yes I-l"-I I I I I I I I I I I I I I I I I I I I I I FLORIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"P TYPE 1.97 RFV 3 Y SHEE1'" IABLFS PR 93 lcR3 I 1OHER ITEM TAG NO.I DESCRIPTION I TYPE GORY EXISTIHG IR UIRED I MENT I UALIFICATION I UALIFICATION I REDUNDANCF.I SUPPLY I VARIABLE INSTRUMENT RANGE QA I CATE-I I REQUIRE-I EHVIRONMENTAL I SEISMIC I VSC FOP I JUSTIFICATION DISPLAY IA1chvIOH I srHFnULF/Bl IDetector I I A.I IDetector I hx I I Detector I 43 I I Detector f12 Jl&01A Jl-001B Jl&010 Jl&01D JR-001B JR&01C JR-001D Neutron Flux l B 1 2X I 10~X I I 10~X I to 100X I I to 200X I Full I Full I Power I Power Comply IFor the De-I Itectora refer I Ito Justifica-ltion.Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note 11 Note ll Note 11 Note ll Note ll Note 11 Note ll Note 11 Note ll Note 11 Note ll I Four I Separate IChannels lof wea-Isurement INotr 1 I I MA I I I INote 1 I IMR I I I INote 1 I lw: I I I INote 1 IMD I I,I INote 1 I lych I I I INote l I IMB I I INote 1 I INC I I I INote 1 I IMD I I I INote 1 I IMA I I I I+ote 1 I IMR I I I INote 1 I lw: I I I INote 1 I IMD I I I Ves Yes Yes Vea SAS SpnS SAS SPDS SAS SPDS SAS SPDS Ves Ves Veal I I Veal I I Yes I I I ver I I I-I I I-I I I-I I I-I I I-I I I-I I I-I I I Voslehr neutron If4ux 4nstrnmrn-Itation was not veal1ncluRrR as lpart of the Ilnrpnsn.ho VeslFqu4nment Liat.ITt 4a qna14f1oa lfor short-term veal post-1oca an~I per forms I ts linten~rd safatv Ifunctlon fRPS lhrtuatfon1 Iwithin this lahott t4me Iperlod.I-I I I-I I I-I I I-I I I-I I I B2 l91 Reed I Control Rodl I Switches I Position I I DDPS CEA Display IADS I I B 3 I Full in I Full in I N/A I or not I or not I I full in I full in I N/A N/A N/A INote INS I I Note INS I I Note INS I Iwote INS I h I I I r I I I h~I I I h I I I Yes SAS Ves Vea I I Ve a I HAS Call 1 n Ior not all in)I-I I I-I I I FLORIDA POWER AND LIGHT ST LUCIE UNIT NO 2 REGULATORY Np TYPE B V 1.97 REV 3 Y SHEET" (Continued)

RR 23, 1aRS VARIABLE INSTRUMENT RANCE QA ITEN TAC NO.DESCRIPTION I TYPE CATE-I I REQUIRE-I ENVIRONMENTAL I SEISNIC I I POWER I DISPLAY LOCATION I SCHFDUT,R/

GORY I EXISTINC I REQUIRED I NENT I UALIFICATION I QUALIFICATION I REDUNDANCF I SUPPLY I CR TSC ROF I JUSTIFICATION AT-2203 I AR"2203 RCS Solublel Boron Con-centration I 0 to I 6000 3 IOto I 1250/5000 ppm I ppm N/A N/A N/A INote 4 I INS I I I I INote 4 I INS SAS Yes yes I I I I--I I I I I I I I I I I I yeslThere are two I add 5 t5 one 1 lhoron con-lcentrat5on lmessurement.

lpossil 51 (ties, I 1-Nanual I grsh I sample I primary I means.I see P1s I 2-Post hcc5-dent I Sampling I B4 TE-1115 TI-1115 TE-1125 TI-1125 I RCS Cold I Le8 water I Temp I (Loop 2hl)I I I I RCS Cold I Le8 water I Temp I (Loop 2B1)I 3 I 0 to I 50'F to I 600 F I 400 F N/A B 3 I 0 to I 50'F to I N/A I 600 F I 400'F N/A N/A N/A N/A N/A INote 7 I SAS i@A I I INote 7 I Yes ISA I I I INote 2 I SAS I I INote 7 I Yes ISB I I I I Yesl yesl I I I I I I I-I-I I I I I I I I veal veal I I I I I I I-I-I I I I I I I B5 ITE-1112HA IRCS Hot Le8 I I IWater Temp I I (Loop 2A)ITE-1112HB I I I Izcc IDisplay A I I Ircc Display B TR-1112CA/

HA B I 1 I 50'F to I50'P to I Comply I I 750'F I700'F Note 10 Note 10 Note 18 Note 18 Note 18 Note 11 Note ll Note 11 Note ll Note 11 I TE-1112ND I I I TF.-1112HA I I I zcc I Display B I I Irc I Display A INote 1 I INA I I I INote 1 I INR I I I INote 1 ISA I I I INote 1 I ISB I I I INote 1 I I Sh I I I SAS SPDS SAS SPDS Yes yes Yes I yesl Yesl I I l I l I I Yesl Veal I I I I I I I-I-l I I I I I I I-I-I I I I l l I I-I-l I I I I I I Justified ear Tnter5m opera-tion (Refer to RA packaee$3a.1 Suhmit-tpfl+5th incFRsn.4a Fau5pment I.ist).TF-1117PA and TF.-1122HR are recorded.1S34H P LORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"PARAMET TYPE B V 1.97 REV 3 Y SHEET" (Continued)

N FR 73~19g3 VARIABLE INSTRUMENT RANGE gh I CATE-I I RE/DIRE-I ENVIRONMENTAL I SF ISMIC ITEMI TAG NO.IDESCRIPTION ITYPE GORY I EXISTING IR UIRED I MENT I UALIPICATION IOUALIFICATION I REDUNDANCE I SUPPLY I FOF I JUSTIPIrhTION Tsr.I PowER I DISPLAY IAKATIDN I srwmoI.F/I TE-1122HA I I ITE-1122HB I I IIcc IDisplay A I Ilcc IDisplay B I I'IR-1122CB/

HB IRCS Hot Leg I IWater Temp l(Loop 2B)I 1 I 50'P go I50'F to I I 750 F I 700 F Comply Note IO Note 10 Note 18 Note 18 Note I8 Note 11 Note ll Note 11 Note 11 Note 11 TF.-1171WB I I TE-1122HA Ir.r.Display B ICC Display A INote 1 IMA I I<ote I IMB I I<ore I I sh I INote 1 isa I lwote I Isn I I I~I I I I Yes ves SAS spns I I SAR I spns I vp.$ve$I I I vesl I I-I I-I I I-I I I veslJnstIFIe~

For l Interim Opera-Ition<>o<er veslto Fn Package l>%4,1 Suhmlt-lted w5th-IInrr4sn.ho IFcuipment I Id$t>.ITF.-I 1.17NA an~ITv-117>nn are lrecorded.-I I I B6 ITE-1112CB I I Icc I Display B I I I TE-1112CA I RCS Cold Leg Water Temp (Loop 2A1)RCS Cold Leg Water Temp (Loop 2A2)I I IIcc I IDisplay A I I I I TR-1112CA/

I HA I I TE-1122CA I I IIcc I Display A RCS Cold Leg Water Temp (Loop 2Bl)TE-1122CB RCS Cold Leg Water IICC I Temp IDisplay B l(Loop 2B2)I I ITR-1122CB/I I HB I I I 1 I 50'F to I50'F to I Comply I 750'P I700 P I 1 I 50'F to I50'F to I Comply I 750'F l700'P 50'P to I50'P to 750'F I700 F I rumply I I 1 I 50'P to l50'P to I Comply I 750 F I700'F Note 10 Note 18 Note 10 Note 18 Note 18 Note 10 Note 18 Note 10 Note 78 Note 18 Note 11 Note ll Note ll Note ll Note 11 Note ll Hote II Note 11 Note 11 Note ll I TE-1112CA I I Irc I Display 4 I I TF.-1112m I I Irc I Display B I I TF.-1177m I I Ir.r.I Display B I I TE-1122cA I I Icc I Display A I I I I INote 1 IMB INote 1 ISB I INote 1 IMA INote 1 Ish I INote 1 lsh I INote I IMA INote I lsh I INote I INB INote i lsn I INote 1 ISB I shs I Spns I Yes SAS SPDS Yes Yes SAS Sr DS yes SAS spns Yes Yes Yes I I-I I I ves I I-I I-I I I ves I I-I I I Yes I I--I I I--I I I YeslJustffied For l Interim nner--lation (gefer Ito FO package I834.1 suhmlt-vealted w4tb IIOCFRSO.ho lFauinment II.1st).I>F.-111och and-ITF.-I lpycn are lrecorded.

I yes I I I I I veal I-I I I-I I I FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATOR"P TYPE B V E 1 97 REV 3 Y SHEET" S (Continued)

FR 73, lag3 YeslFxistlng range Icnnslrlorod laccentahle Veslpen>lng An<8 I disposition.

I--1 I I-I I I-I I I--, I I I-I I I I veal I=I I I I veal I I I I I-I I I I I I I I I I-I I I I I I I I I I-I I 1 I I INote 7 I I PT-1108 I I W'-1 107 I I I Icc I Display n I I rr.r.I Display A I I PI-1108-1 I I I 1 r-1 107-1 0 to 3000 I psia I B7 I PT-1107 I I I PT-1108 I I IICC (Display A I I I lice I!Display B I I I IPI-1107-1 I I I I I I PI-1108-1 I I Pressurizerl I Pressure I (Rcs I Pressure)Note 11 Note 9 SAS SPDS 0 to 4000I Comply psig INote 7 ISA Note 9 Note ll SAS SPDS I I INote l.I I SA I I I Note 11 Note 18 Yes INote 1 Note 18 Note 11 Ves ISB I I~I INote 2 Isn Note 18 Note 11 Yes I Iwote 2 Ves Note 11 Note 18 ISA I INote 7 I SA I Yee Note ll Note 18 PR-1108/IR-1110X VARIABLE INSTRUMENT RANGE Qh I CATE-I I REQUIRE-I ENvIRUNMENTAL I sEIEMIc I I PowER I DlsPLAY LochvroN I srnPDlrLFI ITEM TAG No IDEscRIPTIDN ITYPE I G0RY I ExlsTING IRE UIRED t MENT I UALIFIchTIDN loUALIFIGATIGN I REDUNDANGEI sUPPLvl cR Tso Fop'rrsrlprrhvrow I Display A I I I ICC I Display B 56 Core I Core Exit Exit'Iher I Temp mocouplee I I ICC t I B 3 l32'F to 12300 F IZOO'F to I I2300'F N/A NIA N/A INote 1 ISA lsn I lwote l ISA I I I INote 1 Isp I I Ves SAS SPDS Ves SAS SPDS I-I-I I I I I I I I I I 1 veal vesl I I I I I I I I I veal vel I I I I I I I I B9 16 Heated Junction Ihermo-couples ICC I Display A I RLEV-HA RLEV-PA IICC I Display 8 I RLEV-HB IRLEV-PB I Coolant I Inventory I B I 1 Bottom of Bottom of IHot Leg IHot Leg (to Top of Ito Top of IVessel.)Vessel Comply Note 10 Note 18 Note 18 Note 11 Note ll Note ll gSA and 8SB ICr.Disp1 ay RLEV-HB RLFV-PD Ir.C Display RLFV-nh RLFV-PA INote l Ish ISB I I INote 1 B ISA I I I I Note A ISB I I I I ves I.SAS SPDS I ves I~SAS SPDS I I-I I I I I I I I I Veal I I I I I I I I Veal I I I I I I I I IJust1fle<

far!interim onera-ltlon (ne<er tn IFA)Package Iwo, 71~7 suh-Yeslmitted with l10rFnsn.ha I Fquipmen t Irdst>.karen~l information is veslavallahle in ISAS.I I I 1S>4w

FLORIDA PONER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY G Np TYPE B VARI 1.97 REV 3 Y SHFET" (Continued) 1983 VARIABLE INSTRUMENT RANGE QA I I pOTTER ITEMI TAG No IDEscRIPTIQN ITYPE I G0RY I EzisTING IREQUIRED I MENT I UALIFIchTI0N IQUALIFIcATIGN I RFDUNDANGFI sUPPIYI nlspLAY LorhvroN I Tsr.Fop I SrnpwrLE/JTLsTTPTrATTON B10 IICC IDegrees of I Display A ISubcooling ITMARHEAD-Al ITMARRCS-A I TMARCET-A I TMARUR-A Ilcc IDisplay B I ITMARHEAD-SI ITMARRCS-s I ITMARCET-B I TMARUR-B I700 F I sub-Icooling Ito 2100'F ISuperheat 1200'F I Comply I sub-I cooling Ito 35'F ISuperheatl IRefer to IFQ for Al, IA2, A3, 89 lanfl Cl.IRefer to IEO for Al, IA2, A3, p9 land Cl.Note 11 Note'll N/A INote 1 I ISA I I I I I I I I I I INote 1 I ISB I I I I I I,I I I I I Ves spns Ves SAS SPng I Veal Yesl I I I I I I I!I I I I I I I I I~I I veal veal I I I I I l I I I I'I I I I I I I Bll IPT-1107 I I I PT-1108 I I IIcc I Display A I IIcc I Display B I IPI-1107-1 PI-1108-1 PR-1108/IR-1110X I Pressurizerl I Pressure I (RCS I Pressure)B 1 IO to 3000 IO to 4000I I psia I psig Comply Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note ll Note ll Note 1l Note 11 Note 11-Note 11 I PT-1108 I I I PT-1107 I I I Icc I Displav 8 I I Ir.r.I Display A I I Pi-1108-1 I I I PT-1107-1 INote 7 I lgn I I I INote 2 I ISA I I INote 3 I ISA I I I INote I Iss I INote 2 I Isn I I I INote 7 I ISA I I I INote 7 I ISA I I I SAS Spns SAS Spns Ves Yes Ves Yes ves I I I veal I I-I I I I I I-I I I-I I I-I I I veslpxistinR range lconsidere<

lacceptable Veal pending A~S Idisposition.

I-I I I-I I I-I I I I I I-I I I 1S34N PLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY Np TYPE B V 1.97 RFV 3 Y SHEET" (Continued)

FR 73i lo83 VARIABLE INS1RUMEHT RANGE QA I I CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I PowFR l DTHPLAY McATTnH I srwvDDLv/ITEMI TAG NO.I DESCRIPTION 1TPE I GORY I EXISTING IR UIRED I MENT IOUALIFICATION IOUALIPICATION I REDUNDANCEI SUPPLY I CR TSr.FOF I JUSVIVTrA'rTON B12AILE&7-14A IContainment I I Sump Water I I uvel I LI-07-14A I (Narrow I I Range)I I I IR-07-13A/

I 14A I I 2 l-7 ft El INarrow I Comply Ito 0 ft El Range (Sump)Note o I Note 18 Note 18 Note 11 Note 11 Note 11 N/A Iwote 7 I SAs IsA I Song I I INote 7 I Ves I SA I I I INote>I vea ISA I veal I I-I I I I I veal B12BILE&7-13A IContainment B I IWater Level I I I(Wide Range)I I LE&7-13B I LI&7-13A LI&7-13B I LR&7-13A/14A 1 I-l ft El IWide I Comply Ito 26 ft IRange I I El I (Plant I ISpecific)I Note 9 Note 9 Note 18 Note 18 Note 18 Note ll Note ll Note ll Note ll Note 11 I LF;07-13H I I LF~7-13A I I I Ll-07-13B I I I LT~7-13A INote>I ISA,I I I Iwote 2 I Isn I I I INote 2 I ISA I I I lwote 7 I ISB I I I INote 2 l I SA I I I SAS SPDS HAS Spj)$Ves Ves Yes I Yesl Yesl I I I I I I l Veal Veal I I I I I-I-I I I I I-I-I I I I I-I-I I I I B13 PT&7&A IPT&7&B PI&7-4A/I 5A.I PR&7-4B/I SB I I Containment Pressure-(Mid Range)1 IOto60 psig I I IO to I Comply IDesign I IPressure I I(psig)Note 18 Note 18 I Note 18 I I Note 18 Note ll Note ll Note 11 Note 11 I Pv-07-4H I I PT"07-4A I I I PR-07-4H/I SH I I Pi-07-4A/I 5A I lwote>I IsA I I I INote 7 I I Iwote 7 l ISA I I I IHote 2 I Isn I I I SAs SPDS SAS SPDS Yes Yes I Veal Vealneaian Pressure I I lis 44 naia I I I I Veal Yesl I I I I I I I-I-I I I I I I I I-I-I I I I I I I-10-1s34+

FMRIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY G~97 RFV 3"PARAMETH<

Y SHEET" TYPE B VARI Continued) lose VARIABLE INSTRUMENT RANGE Qh I I CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I PQNER I DIHPLAY LocATIDN I SONFnnT,E/

ITEMI TAG NO.IDESCRIPTION ITYPE I GORY I EXISTING IR UIRED I MENT IQUALIFICATION IOUALIFICATION I REDUNDANCFI SUPPLYI CR TSC EOFI JITSTTPIlATTON B14 ISee FSAR IContainment ITable IIsolation l6.2-52 IValve IPosition'1 IClosed-IClosed-I Comply INot INot I Closed I Closed Note 9&Note 10 Note 11 ICatesory T Iredundancv ldoes not lapply he-Icause a Isecnndarv Iwote 7 ISA,SB I I, I I SAS I vesl I I Yes l sseetv Rrsr1e lrR nositinn I indi cs t i oo i s I provided as Irenuired.

nnav Ithe valves Icontainmentl lisolation Ivalve is Inormally lavai>alle lon each lline pene-I trating the l Icontain-I lment.Fm-I Iceotions tol Ithe rule lare ex" I Iplained in I IFSAR Sec-I Ition 6.2.4.I I I~Irereivinp CTS lare in SAS, lvSC&Rnv.IFor valves I iustifieS fnr l interim opera-Ition refer tn l)OCFRSn.4o I'Fun(nmeot T.est~I I I I I I I I B15 I PT-07-4A I I I IPTW7-4B Pr-07-4A/5A PR-07-4B/I 5B I I Containment Pressure (Mid Range)I B 1 IO to 60 I-5 psig I Comply I psig I to I I Design I IPressure I Note 18 Note 18 Note 18 Note 18 Note ll Note ll Note ll Note 11 I PT-07MB I I I PT&7&A I I I PR-07-4B/I 5B I I PT~7WA/I SA I INote 7 I I Sh I I I INote 2 I ISB I I I INote 2 I ISA I I I IMote 7 I ISR I I I SAS SPDS SAS SPDS Yes Yes I Yesl I I I I I vesl I I I I I--I I I I I I-I I I I I Yes Ves IRanse provided Idnes not rnver lthe lower end lof the reouired Iranse (-<nsiR Ito 44 psisi.I Additinna1 lpressu e trans-lmitters covers I-S to 17<ps<R I<see Item 0111.I 1 a%4M PLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY

.97 REV 3"PARAMETHt Y SHEET" TYPE ABLES NO 73, log3 VARIABLE I CATE-ITEN TAG NO IDESCRIPTION ITYPE I GORY INSTRUMENT RANGE I REQUIRE-I ENVIRONMENTAL I SEISNIC I I PowER I DIsPLAY LochTIAN I srwFDULv/ICore Exit I Temp Display B I Cl I56 Core I Exit I'Ihermo-Icouples I IIcc IDisplay A I I I IIcc 1 l32'F to I I2300'F 200 F to I 2300 F Comply Note 10 Note 18 Note 18 Note 11 Note ll Note ll I 7SA and I 7SR per I Ouadrant I I'I Tr.r.I Display B I I I Icr.I Display A INote 1 ISA Isn I I Iwote 1 IsA I I INote 1 ISR I I I I I I ves I SAS I spns I l ves I SAS I, spns I I--I I l I I I I I I veal I I I I I I I veal I I I I I I--IJustified for I4nter<m opera-ltlon fRefer to l RA Packaee INo.71.1 suh-veslmltterl with I1ArFRSA,4o Ipquipment IList).>rend Veslinfnrmatlon ls lavailahle in I SAS.I C2 None ICirculating IPrimary ICoolant Radioactiv-C lity Concen-Itration or IRadiation I&ve1 in I Il/2 Tech I ISpec I Ilimit to I I100 timesI JTech SpecI Ilimit I I I I I.I I I I I I Ipending the Iresults of the Istu~v regarR5no lequipment Iavailahilltv, lto b>>completed lhv nec>on~.I I C3 Primary Coolant (Gamma Spectrum)Pc-Xe-133 Pc-co-60 I PC-CS-134 IPT-1107 IPressurlzer I IPressure I(RCS PT-1108 IPressure)

Icc Display A I I IIcc I IDisplay B I I I Pc-I-131 Analysis of I C 3 Il uci/ml Ito I10 Ci/ml I 10 uci/ml I N/A Ito I I10 Ci/ml I lor I ITID-14844I Isource ITerm in ICoolant I Volume I 1 IO to 3000 IO to 40001 Comply Ipsia Ipsig N/A Note 9 Note 9 Note 18 Note 18 N/A I I Note ll I I Note ll I I Note ll Note ll I I N/A I N/A I I I I I I I I I INote 2 I Isa I I I INote 2 I ISA I I I INote 1 I ISA l I I~INote l.I Isn I, I I I PT-1108 I I I Pv-1107 I I I Icc I Display R I I Irc I Display A I SAS SAS SAS spng SAS spns Ves Yes I veal veal I I I I Yesl Veal I I I I Yesl Yesl I I veal veal I I I I I I I I I I veal I I I I I veal I I I I I-I I I I I I-I I I I I Yesl Fxisting range Iconsi<ere~

lacceptahle veslpend5ng AVOWS ldisposition.

I-I I I-I I l-12-1S34H e

'FIORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATr UIDE 1.97 REV 3"P UMMARY SHEET" TYPE C LES (Continued)

FNAFH>3, lqns TAG NO.VARIABLE INSTRUMENT RANGE QA I CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I POWER I I DESCRIPTION TYPE I GORY I EXISTING UIRED I MENT IOUALIFICATION IQUALIFICATION I REDUNDANCEI SUPPLYI DISPLAY LocATTUN I scHFDTILF/

CR TSC FOF I JUSTIPTCATION IPI-1107-1 I I IPI-1108-1 I I I PR-1108/LR-1110X Ipressurizer I C IPressure I (RCS IPressure) 1 IO to 3000 IO to 4000I Comply Ipsia Ipsig Note 18 Note 18 Note 18 Note 11 Note 11 Note 11 I PI-1108-I I I I Pj-1107-1 INote 7 ISB I I I INote 2 I lsh I I I Iwote'>l ISA I Yes Yes veA I-I I I I I I--I I I I l I-I I I I I lpx1AtlnR ranae Iconsidere>

laccoptahle l pend 1nR h'rWS I dispos1 t inn.I I I I C5 I PT7-4A I I I PT-07-4B IContainment I C Ipressure I l(Mid Range)I PI-07-4A/5A PR-07-4B 5B C6A ILE-07-14A I Containment.

I ISump Water I ILevel I LI&7-14A I (Narrow I IRange)I I I LR&7-13A/I 14A I I IO to 60-5 psig (Comply I I psig Ito IDesign I Ipressure I 2 I-7 ft FJ.INarrow I Comply Ito 0 ft FJ.IRange l(Sump)Note 18 Note 18 Note 18 Note 18 Note 9 Note 18 Note 18 Note ll Note 11 Note ll Note 11 Note ll Note 11 Note 11 INote 2 I Ish ,I I I INote 7 l ISB I I I INote 7 I Ish I I Iwote 2 l ISB I I PT-07-4H I I I PT-07-4A INote 7 ISA I INote 2 IsA I INote 2 ISA I N/h FR&7&8/5B I PI&7-4A/Hh SAS SAS SPDS SAS spns Yes Yes Yes I I I Yes I I I-I I I-I I I Yes I Yesl I I I I I-I I I I I I-I I I I I YeslnanRe prnvlded Idoes nnt cover lthe lower end Yeslof the require~lranae f-S psiR Ito 4<pATRi.lhddi tional l pressure trans-lmitters covers I-S to 17'A<R l Csee Ttem C]ll, I C6B ILE&7-13A I I I LE~7-13B I I I LI&7-13A I I ILI&7-13B IR-07"13A/

14A IContainment C IWater Level I l(Wide Range)l 1 I-1 ft El IWide I Comply Ito 26 ft IRange I I El I (Plant I I Specific)I'ote 9 Note 9 Note 18 Note 18 Note 18 Note 11 Note ll Note 11 Note ll Note 11 I LE&7-13B I I I LE&7-13A I I I LT~7-13B I I.I LI~7-13A Iwote 2 I Ish I I I I Note 2 I Isn I I I INote 7 I ISA I I I INote 7 I isa I I I Iwote 7 I lsh.I I I SAS spnS SAS spns Yes Yes I I I I I-I-I I I I I-I-I I I I I-I-I I I I I Yesl vesl I I I I I I Yesl Yes!-13-1 S%4M

~~~'LORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY GU 97 REV 3"PARAMETER SHEET" TYPE C VARIA ontinued)NOV'73, 1983 VARIABLE INSTRUMENT RANGE Qh ITEM TAG NO.DESCRIPTION I TYPE I PowER I DIHPLAY LocATJoN I scHRrnrr,R/

GORY I ExIsTING I UIRED I MENT IQUALIPIGATIQN IQUALIFIchTIQN I RFDUNDANGEI sUPPLvl cR Tsc Fopl JUSTJPJOATToN C7 IRD-26&0 IContainment I C 3 Il R/hr Il R/hr N/A I I Area Ito Ito I IRadiation I10 R/hr I10 R/hr I IRD-26-41 I I I RC-26-40 I I I RC-26-41 I I I RR-26-40 RR-26-41 IRMS Console N/A N/A N/A INote?I ISA I I I INote?I lsR I I I INote?I Ish I I I INote?I ISR I I I INote?I Ish I I INote 2 I ISR I I I INote 6 I INS I SAS SRng SAR Sr ng Ves Yes Yes Yes Ves I veal I I I I I Veal I I I I I-I I I I I I-I I I I I I-I I I I I I-I I I I.I I-I I I I I RMS Console I Radioactiv-Ii ty-Noble IGas Effluentl I from Conden-I Iser Air Re-Imoval System IExhaust I C8 I RE-26-11 I Ef fluent 3 I10"7 Iuci/cc I10-2 I Iuci/cc I I I10 6 N/A I I to uCi/cc to 110 2 luCi/cc I I N/A N/A N/A INote 4 INs I INote 6 INs SAS SPDS Yes I Yesl Veal I I I I I I I-I-I I I I C9 IPT-1107 IPressurizer IPressure (RCS Pressure)IPT-1108 I I IICC Display A ICC Display B I c I 1 IO to 3000 IO to 4000 I Ipsia Ipsig I Comply I Note 9 I I r I Note 9 I I Note 11 I I I Note 11 I Note 18 I Note ll I PT-1108 I I I I PT-1107 I I I ICC I Display R Note 18 Note ll ICC Display A INote?I Isn I I I I I INote?I ISA I I I INote 1 I ISA I I I INote 1 I lSR I I SAS spns SAS spns Yes Ves I Yesl I I I I I I I Yesl I I I I I-I I I I I I-l I I I I YesIFxtsting range Icnnalrlerea lacceptahle IrM naming Amrs Vealdlsnositinn.

I I-I I I-I I I PLORIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY

.1.97 REV 3"P Y SHEET" TYPE C V (Continued

)N FR W3, 1983 ITEN TAG NO.VARIABLE INSTRUMENT ROOSE QA CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I POWER I DESCRIPTION I TYPE I GORY I EXISTING UIRED I MENT I UALIFICATION I QUALIFICATION I REDUNDANCP.I SUPPLYI DIsPLAY LocATIQN I scHFDIKRI.cR vsc Fnpl JUrnplrhvynN IPI-1107-1 IPressurirer I C I IPressure I I(RCS IPI-1108-1 IPressure)

PR-1108/LR-1110 X C10 IHydrogen IContain-I ISampling lment land IHydrogen IAnalyzer IConcen-I Cubicle I tration l(Unit 2A)I I IHydrogen ISampling land IAnalyzer I Cubic1e l(Unit 2B)I I IHydrogen Analyzer Indicating and Recording I Cubic1e I Sh I IHydrogen IAnalyzer I Indicating I and I Recording I Cubicle SB I psia Ipsig I Comply I I I I 1 I0 to 10X IO to 10 I (Capable IVol-X I of Oper I (Capable lating lof Oper-I from-5 lating Ipsig to Ifrom-5 l44 psig)Ipsig to I Maximum I De sign IPressure)l 1 IO to 3000 IO to 40001 Comply Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 11 Note ll Note 11 Note 11 Note ll Note ll Note 11 I PI-1108-1 I I-I PJ-1107-1 IHydrogen Isampling land I Analyzer Icubicle l(Unit 2B)I IHydrogen Isampling land lhnalvzer I Cubicle I (Unit 7A)I IHydrogen IAnalyzer I Indicating land Inecording I Cubicle Igg I Igydrogen IAnalyzer IIndicating land IRecording I Cubicle I SA I INote 2 Yes I INote 2 I SA Yes INote 2 I I sA,I I I I I I INote 7 I Ign I I I I I I I I I I I INote 7 I ISA I I SAS SPDS SAS SPDS Yes INote 7 I Yea ISB I I I Isn I I I INote 7 I Yea ISA I I I I I I I veal I I I I I I veal I I I I-I I I I IFxistkno rango I cnnsi~erod lscceptable I pending Aou<Idiaposition.

I I I I Yes I nesign Prosaure Iis 66 psig.I I I I I Yes I-15-I S34H FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P TYPE C V E 1.97 REV 3 Y SHEE1'" (Continued)

FR 73, lo83 ITEN VARIABLE INSTRUMENT RANGE CATE-I TAG NO DESCRIPTION ITYPE I GORY I EXISTING IRE UIRED QA , REQUIRE-IENvIRGNMENTAL I sEIsMIc I I POWER I NENT IQUALIFICATION IOUALIPICATION I REDUNDANCEI SUPPLYI DIsPLAY McATIGN I scNFnnLE/cR Ysc Hopi JUsviprcAvroN'll IPT&7-4hl I I IPT&7-4Bl I I IPI-07-4hl I I IPI&7-4B1 I I I PR-07-'4A1 IContainment C IPress'ure l(Wide Range)l 1 I"5 psig Ito 175 I psig I-5 psig I lto 4 Itimes Inesign IPressure Ifor Steel I Contain-Iment Comply Note 9 Note 9 Note 18 Note 18 Note 18 Note 11 Note 11 Note 11 Note ll Note ll PTW7-481 I I I PT&7-4hl I I I Pr-07-48'I I PI-07-4A1 INote 2 I I sh I I I INote 2 I Isn I I I INote 7 I ISA I I I!Note 2 I Isa I SAS spns SAS spns Ves Yes I.I INote>l'es ISA I I l I veal I I I I I veal I I I I I-I I I I I I-I I I I I I-I I I I I veal near an>reswire lis 44 osis.I vesl I I-I I I--I I I I I I RC-26-14 I RR-26"13 I RR-26-14 I I IRNS IConsole I I I I-I I C12 IRK-26-13C IContainment I I Effluent IRadioactiv-RE-26-14C lity Noble IGases from , IIdentified I Release IPoints RC-26-13 I I I I I 10 7 I10~I Comply uCi/cc to luCi/cc tol llO 2 I10 2 luCi/cc luCi/cc.N/A Note 18 Note 18 Note 18 Note 18 I I Note 18 I I I Note 18 N/A Note ll Note ll Note ll I I Note ll I I I Note 11 I I I I" I N/A., Note ll I N/A N/A INote 7 ISA I I I INote 2 I ISB I I I I I I I INote 2 I I SA I I I INore 2 I ISB I I I INote 2 I I SA I I I INote 7 I Isn I I I INote 6 I lNS I I I SAS I Veal>esl spns I I l I I I SAS I Veal Yesl spns I I I I l I I I I I I I I I I Yes~I.-I-I I I I I I I Yes I-I-I I I l I I I ves I--I-I I I I I I I ves I I I I l I I ves I-I-I I I I I I I-16-1534M

FLORIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGUIATOR Np TYPE C V E 1.97 REV 3 Y SHEET" (Continued) 73>14A3 ITEM TAG NO, VARIABLE TYPE GORY I I DESCRIPTION INSlRUMEHT RANCE OA I REQUIRE-ENVIRONMENTAL I SEISMIC I I POWER I DISPLAY LOCATTON I SCHHOHT,H/

ExisTING RE HIRED I MENT OUALIFIGATIGN loUALIFIcATI0N I REDUNDANGFI sUPPLYI cH vsc FoFI JnsvTPTOATToN C13 IRE-26-90A I I IRE-26-90B I I I RE-26-90C I I I RE-26&9A I I I RE-26-69B I I I RE-26%9C I I I RE-26-70A I I IRE-26-70B I I I RE"26-70C I I I RC-26%0 I I I RC-26-69 I I IRC-26-70'I I RR-26-90 RR"26&9 RR-26-70 IEffluent C IRadioactiv-Iity-Noble IGases (from I Ibuildings Ior areas Iwhere pene-I trations and I Ihatches are I I located, Ieg, second-I Iary contain-I Iment and lauxiliary Ibuildings land fuel Ihandling Ibuildings Ithat are Iin direct Icontact withl Iprimary con-I Itainment) 2 I I I I 10 I 10 I uCi/cc to IuCi/cc tol 106 I 103 uci/cc I uci/cc Comply Note 18 I I Note 11 N/A INotp 6 I INS I I I INote 6 I INs I I INote 6 I INS I I I INote 2 I ISA I I.I INote 2 I IsA I I I INote 7 I I SA I I I INote 7 I Isg I I.I INote 2 I Ign I I I INote 2 I ISH I I I I Note 6 I I I I IHote 2 I ISA I I I INote 2 I ISP I I I INote 6 I IHs I I INote 2 I I SA I I I IÃote 7 I ISB~I SAS spns SAS spns SAS SAS SPDS SAS sr ns SAS SAS spns SAS spns SAS'es Yes Yes Yes Yes I vp>>l vpsl I I I I I I I Yesl Veal I I I I I I I vpsl vesl I I I I I I I Yesl veal I I I I I I I Yesl veal I I I I I I veal vesl I I I I I I I veal veal I I I I I I I Yesl veal I I I I I I I veal vpsl I I I I I I I-I-I I I I I I I I--I-I I I I I I I I-I-I I I I I I I I-I-I I I I I I I I-I-I I I I I I I-I-I I I I FLORIDA POKER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P TYPE C V E 1.97 REV 3 Y SHEET" S (Continued)

RR 73 lo83 VARIABLE INSTRUMENT RANGE gh GiTE-I I REQUIRE-IENVIRONMENTAL I SEISMIC I I PDHER I DIspLAY LocATIoN I srHFDIlLF/

TAG No DEscRIPTI0N ITYPE I G0RY I EzisTING I UIRED I MENT I UALIFIchTIDN

'I UALIFIchTIDN I REDUNDANrFI HUPPLYI CR Tsr.FoF I JUHTIFlrhvroN RRR-26-90 RRR-26&9 RRR-26-70 RMS-Console RE-26-12C IEffluent I Radioactiv-lity-Noble I IGases (from I Ibuildings lor areas lwhere pene-Itrations andi Ihatches are I I located, I leg, second" I lary contain-I Iment and C lauxiliary Ibuildings land fuel Ihandling Ibuildings Ithat are in direct contact with primary con-I tainment)I I~2 (10 6 luci/cc to I IOS luci/cc 110 2 luci/cc to ll0-2 Iuci/cc I10-6 luci/cc tol I103 luci/cc 10-6 luci/cc to I 103 luci/cc Comply N/A N/A Note 18 N/A Note 18 Note 11 N/A N/A N/A N/A N/A lwote 6 I INS I I I INote 2 I ISA I I I INote>I ISH I I I INote 6 I INH I I.I INote 4 I INS I I I I I Yes Ves Yes Yes SAS SPDS I--I I I I I I-I I I I I I-I I I I I I-I I I I I Veal I I I I I I I I I I I I I I I I I I I I I-I I I-I I I-I I I-I I I Ves I Ff fluent I (Noble r~<1 Itar1latlon from Ithe contaln-Iment will not lbe released Ithrouah the Ifuel handllna I hull dl na, I I I-18-1$34l4

FLORIDA PONER AND LIGHT ST LUCIE UNIT NO.2 RECULATORY"P TYPE Ii97 REV 3 Y SHEET" ABLES ITEM TAC NO, VARIABLE I I DESCRIPTION I TYPE INSTRUMENT RANGE QA CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I Penm I GORY I EXISTING I UIRED I MENT IOUALIPICATION IOUALIFICATION I REDUNDANCEI SUPPLY I DIsPLAv LOchvTow I srNRnm.E/vsr.Popl JosvzprrhvmN Dl IFT-3306 I I IFIC-3306 I I IFR-3306 I I IFT-3301 I I I FIC-3301 I I IFR-3301 D2 ITE-3303M TE-3303X TI-3303X TR-3303M TE-3303Y TE-3303Z TI-3303Y TR-33032 I Shutdown D I Cooling ISystem Flow Ifrom LPSI Ipump 2A l(RHR System I I Flow)I I IShutdown D ICooling ISystem Flow I Ifrom LPSI I I pump 2B I l(RHR System I I Plow)2 IO to 5000 IO to llOXI Igpm, I Design I Flow 2 IO to 5000 IO to 110XI Igpm IDesign I I Flow I Shutdown I Cooling IHeat Ex-Ichanger 2A loutlet Temp I I (RHR Heat Exchanger) 2 IO'F to l40'F to I l350'F l350'F I Shutdown I Cooling IHeat Ex-Ichanger 2B IOutlet Temp I I (RHR Heat I Exchanger)

D 2 IO'F to l40'F to I I3500F I350'F Comply Comply Comply Comply Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 9 Note 9 Note 18 Note 18 Note 9 Note 9 Note 18 Note 18 Note 11 Note 11 Note ll Note 11 I Note ll Note ll Note 11 Note ll Note ll Note ll Note ll Note 11 Note ll Note ll NIA N/A N/A N/A lwote>I ISA I I I INote 2 I ISA I I I INot.e 9 I ISA I I I INote 7 I lsn I I I.INote 2 I IsB I I I INote 2 I ISB I I I INote y I ISB I I I'Note 2 I I sh I I I INote~I ISA I I INote 2 I Isn I I INote 2 I ISB I I I INote 2 I Ish I I I Iwote 2 I ISB I I I INote 2 I ISA I I I SAS SPDS ves Ves SAS SPDS Yes Yes SAS SPDS SAS S1 nS Ves SAS SPDS SAS SPDS ves Yes vesl I I I I I-I I I Yes I I I-I I I-I I I I vesl vesl I I I I I I I Yesl veal I I I I I I I-I-I I I I I I I I-I-I I I I I I I veal vesI I I I I I I I Yesl Vesl I I I I I I I-I-I I I I I I I-I-I I I I I Veslnen1sm

<4ow 4s I>300 ppm,~>or contn<nnnnt Isnrav flow Isnn 1tnm n~~.I--.I I I vest I I-I I I-I I I-19-1534M PMRIDA POWER AND LICHT ST LUCIE UNIT NO, 2 REGULATORY Np TYPE D VAR 1.97 REV 3 Y SHEEP" (Continued) 73,]SA3 VARIABLE INSTRUMENT RANGE QA I CATE-I I REQUIRE-IENVIRONNENTAL I SEISNIC I I PowER I nlsPLAY LocATIQN I FQFI TSC ITEMI TAG No IDEscRIPTIQN I TYPE GQRY I ExlsTING I UIREn I NENT IQUALIPIcATIQN IQUALIFIGATIQN I REDUNDANcEI sm PLYI SCHEDULE/JUSTIPICATZON I I IPIA-3321 I I ILT-3311 I I ILIA-3311 I Safety Iingection I Tank 2A2 ILevel and IPressure l(Accumula-PT-3311 Itor Tank)PIA-3311 LT-3331 LIA-3331 IPT-3331 I I I PIA-3331 ISafety lin)ection ITank 2B1 ILevel and IPressure l(Accumula-Itor Tank)I LT-3341 ISafety IInjection ITank 282 LIA-3341 ILevel and PT-3341 Pressure (Accumula-tor Tank)IPIA-3341 I I D3 ILT-3321 ISafety I I Injection I I Tank 2A1.I LIA-3321 I Level and I IPressure I l(Accumula-IPT-3321 Itor Tank)I 2 I6.5X to lloX to l93.5X l90X I Volume I Volume lo to 7oo lo to 750 I Ipsig Ipsig Io to 700 Io to 750 I Ipsig Ipsig 2 l6.5X to I93.5X I Volume lloX to I90X I Volume lo to 700 Io to 750 Ipsig Ipsig 2 I6.5X to lloX to I93.5X I90X IVolume IVolume 0 to 700 Io to 750 I psig Ipsig D 2 l6.5X to I10X to l93.5X l90X I Volume I Volume N/A N/A N/A Note 15 N/A Note 18 Note 15 N/A Note 18 Note 15 I I Note 18 I Note 15 I N/A Note 18 I Note 15 I Note 18 I Note 15 I-N/h Note 18 Note 15 Note 18 Note 15 I I Note 18 N/A N/A N/A N/A INote 4 I INs I I INote 4 I I I INote 4 I INS I INote 4 I INS I I I INote 4 I INS I I I INote 4 I INS I I INote 4 INs I I I INote 4 I INS I I I INote 4 I INS I I INote 4 I INS I I I INote 4 I INS I I I INote 4 I INS I I I INote 4 I INS I I INote 4 I INS I I=I INote 4 I INs I I I INote 4 I INS I I SAS Ves SAS Yes SAN Ves SAS Yes SAS Ves SAS Yes SAS Ves SAS Yes Vosl vesl7nn ns<R I lexceeds tank I Idesian pressure-I-land tank safetv Iva1ve set I lpoint.veal veRI I I I I-I-I I I I I Yesl Veal I I I I-I-I I I I I VesI Vesl I I I I-I-I I I I I Yesl Veal I I I I-I-I I I I I Yesl Veal I I I I-I-I I I I I Yesl Veal I I I I-I-I I I I I Veal Yesl I I I I-I-I I I I I-20-1S34M

PLORIDA POHER AND LIGHT ST LUCIE UNIT NO+2 REGULA~tp TYPE D IDE 1.97 REV 3 Y SHEET" ES (Continued)

ER 23, 1483 I ITEMI TAG NO.VARIABLE INSTRUMEHT RANGE OA I P0%%I DISPLAY LOCATION I SCHEDTlT,P/

I DESCRIPTION ITYPE I GORY I EZISTING I UIRED I MENT I UALIFICATION I UALIPICATION I REDUNDANCE I SUPPLYI CR YSC EOF I JUCI'TPTCA'rTON D4 IV-3624 I I IZI-3624 IV-3614 I I I ZI-3614 V-3634 ZI-3634 V-3644 I ZI-3644 ISafety Iingection ITank 2Al IIsolation IValve IPosition I(hccuiula-Itor Tank)I ISafety Iinjection I Tank 2A2 IIsolation I Valve IPosition l(Accumula-Itor Tank)I I Safety lin)ection ITank 2B1 I Isolation I Valve I Position l(hccumula-Itor Tank)I I Safety Iingection ITank 282 IIsolation I Valve IPosition l(Accumula-Itor Tank)I 2 IClosed lor Open I IClosed I Comply lor Open 2 IClosed lor Open I I I IClosed I lor Open Comply 2 I Closed I Closed I lor Open lor Open Comply 2 I Closed I Closed I Comply lor Open lor Open Note 4 Note 18 Note 9 Note 18 Note 9 Note 18 Note 9 Note 18 Note 1 I Note 11 Note ll Note 11 Note 11 Note ll Note ll I Note 11 N/A N/A N/A N/A INote y l ISA I I I Iwote 2 I I SA I I I I I INote 2 I I sh I I, I INote y'I lsA I I I I I I I I I INote y I ISB I I I INote 2 I ISB I I I I I I INote 2 I isa I I I INote 2 I Isg SAS Yes SAS Yes SAS Yes SAS Yes I Yesl Yesl I I I l I I I-I--I I I I I I I I I I Yesl Yesl I I I I I I I-I-I I I I I I I I I I I I I I I I I Yesl veal I I I I I I I-I-I I I I I I I I I I I I I I I I I Yesl veal I I I I l I I-l-I I I I I I I I I I I I I I I D5 FT-2212 PIA-2212 IBoric Acid ICharging I Plow D 2 IO to 150 IO to 110ZI Comply Igpm!Design I Flow Note 9 Note 18 Note 31 Note ll N/A INote 2 I ISA I I I INote 2 I I sh I I I SAS SPDS Yes veal I I-I I I Yes lnesian fIow lis 132 sum.I-I I I-21-I S34w FLORIDA POHER AND LIGHT ST LUCIE UNIT,NO.2 REGULATO"P TYPE D V DE 1.97 REV 3 Y SHEET" S (Continued)

FR 73, 1981 I PONER ITENI TAG NO.I DESCRIPTION ITYPE GORY I EXISTING IR UIRED I MENT I UALIPICATION IQUALIFICATION I REDUNDANCEI SUPPLYI VARIABLE INSTRUMENT RANGE QA I CATE-I I RFA}UIRE-I ENVIRONMENTAL I SEISMIC I DISPLAv ux;ATION I HOPI SCHFDHLR/JUSTZFXCAVTON D6 I FT-3321 I I IFT-3323 I I I FI-3321 I I I PR-3313/IFR-3323 I IPT-3311 I I I PT-3313 I I IFI-3311 I I I PR-3313/IFR-3323 I IFT-3331 I I IFT-3333 IHPSI Flow I Loop 2A1 l(Cold Leg)HPSI Flow Loop 2A2 (Cold Leg)IHPSI FLow ILoop 281 I (Cold Leg)FI-3331 PI-3341 FR-3333/I FR-3343 I IFR-3333/IFR-3343 PT-3341 IHPSI Flow ILoop 282 I (Cold Leg)IPT-3343 2 IO to 400 gpm I IO to 110XI Design I Flow I I I Comply 2 IO to 400 IO to 110XI Comply gpm IDesign IFlow D 2 IO to 400 IO to llOZI I gpm I Design I Flow Comply 2 IO to 400 IO to 110XI Comply I gpm I Design I Flow Note 18 Note ll Note 18 Note 11 Note 18 Note 11 Note 18 Note 11 Note 18 Note 11 Note 18 I Note 11 I Note 18 Note ll Note 18 Note 11 Note 18 Note 11 Note 18 Note ll Note 18 Note 11 Note JH Note 11 Note 18 Note 11 Note 18 Note 11 Note 18 Note 11 Note 18 I Note 11 N/A N/A N/A N/A INote 7 I ISA I I I INote 2 I Isn I I I lwote>I Ish I I I INote 2 I ISB I INote y I IsA I I I INote 2 I lgn I I I INote 7 I Ish I I I INote 2 I isa I I I INote 7 I ISB I I I INote 2 I'gh I I INote 2 I ISB I I I INote 7 I ISA'I I INote>ISB I I I I I Iwote 7 I ISA I I INote 2~I I gs I I INote 2 I ISA I I I SAS vea Yes SAS SAS vee Yes SAS SAS vea Yes SAS SAS Yes Vea I veal I I I I Yesl I I I I I-I I I I I I-I I I I I I veal I I I I I veal I I I I I-l I I I I I--I I I I I I>eel I I I I I veal I I I I I--I I I I I I-I I I I I veal I I I I I I veal I I I I-I I I I I I-I I I I I Yes I I I I I I-I I I veal I I veal I I--I I I-I I I veal l I veal I I-I I I-I I vea I I I I veal I I-I I I-I I I Veal peat an f1ow lis 3m asm.-22-1 S%414 FLORIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGUIhTOR"P TYPE D V E 1.97 REV 3 Y SHEET" (Continued)

]SA3 VARIABLE ITEM I TAG NO I DESCRIPTION TYPE GORY I EXISTIHG I I REQUIRE-I ENvIRQNMENTAL I sEIsMIc I I PONER I UIRED I MENT I UALIPICATION IQUALIPICATION I REDUNDANCEI SUPPLY I DISPLAY LochTIGN I scHFDULE/I FI-3315 I I IFR-3317 I I IFT-3325 I I I IFT-3327 I I I FI-3325 I I IFR-3327 HPSI Plow Loop 2B (Hot Leg)IFT-3315 IHPSI Flow ILoop 2A I (Hot Leg)FT-3317 D 2 IO to 400 10 to 110XI Igpm Inesign I Flow D 2 IO to 400 IO to 110ZI Igpm IDesign I Flow Comply Comply Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note 11 Note ll Note ll Note 11 Note 11 Note ll Note ll N/A N/A INote>I ISA I I I INote 2 I Isn I I I INote 7 I Ish I I I INote 2 I ISB I I I INote 2 I ISB I I I INote 2 I I SA I I I INote 2 I ISB I I I INote 2 I ISA I I I SAS SAS Yes Ves SAS SAS Yes Yes I veal I I I I I Yesl I I I I I-I I I I I I-I I I I I I veal I I I I I veal I I I I I-I I I I I I-I I I I I VeaIneaian f1ow lis 37n pnm.I ves I I I-I I I-I I I veal I I ves I D7 I FT-3322 I LPSI Flow I I Loop 2A1 I IFI-3322 FT-3312 ILPSI Flow ILoop 2A2 PI-3312 FT-3332 ILPSI Plow ILoop 2B1 FI-3332 IPT-3342 ILPSI Plow I Loop 2B2 I IFI-3342 I I I Design Igpm I Flow 2 10 to 2500 IO to 110XI Igpm lneeign I Flow Comply 2 IO to 2500 IO to 110XI Comply I gpm I ne sign I Plow D 2 IO to 2500 IO to 110XI Comply I gpm I Design I Flow D 2 IO to 2500 IO to 110XI Comply Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note ll Note ll Note 11 Note ll, Note ll Note 11 Note ll N/A N/A N/A N/A INote 7 I I Sh I I I INote 7 I I Sh I I I INote 7 I ISA I I I INote 2 I ISA I I I INote 2 I ISB I I I INote 2 I ISB I I I INote 7 I SAS Yes SAS Yes SAS Yes SAS ISB I I I INote 2 I Yes ISB I'I I Yesl I I I I I-I I I I I I veaI I I I I I-I I I I I I veal I I I I I-I I I I I I vesl I I I I I-I I I I I veslnesisn flow lis 7763 cpm.I-I I I vea I I I-I I I veal I I-I I I vea I I I-I I I-23-I s34M PIORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY

~>p TYPE D V 1.97 REV 3 Y SHEET" (Continued) 23 1 o83 INSTRUMENT RANCE QA I CATE-I TAC NO IDESCRIPTION TYPE I GORY I EZISTING I I REQUIRE-IENVIRoNMENTAL I sEIsMIc I I POWER I UIRED I MENT I QUALIPICATION I QUALIFICATION I REDUNDANCE I SUPPLY I DIsPLAY LochTIoN I'scNFDULE/

cR Tsc EOPI JUsvIPzrATION D8 LT&7-2A IRefueling I Water IStorage ILT&7-2B ITank Leve 1 I I ILT&7-2C I I ILT&7-2D I I ILIS-07-2A I I I LIS&7-2B I LIS-07-2C LIS&7-2D IR&7-2D 2 I 0 to 50 ftl I Top to I Comply Bottom Note 18 Note 18 Note 18 I'ote 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note 11 Note ll Note 11 Note ll Note 11 Note ll Note ll Note 11 N/A INote 1 IMA I I INote 1 I I I INote 1 INC I I I INote 1 I IMD I I I INote 1 I IMA I I I INote I I IMB I I I INote 1 I Iw: I I I Note I I I Nn I I I INote 1 I IMD SAS SPng SAS SI ng SAS Ves Ves ves ves Yes I vosl I I I I I vesl I I I I I veal I I I I I wo I I I I I I-I I I I I I-I I I I.I I I I-I I I-I I I Voslvhe ranoo nrn-Ivfded covers I the useful Veslvolume of the Itank f>.<X tn llnny-of total veal tank holnht).I I No I I I-I I I-I I I-I I I-I I I-I I I D9 AM-101 I AM-109 I AM-10S Reactor Coolant IPump 2A1 Istatus I I Reactor.I Coolant IPump 2A2 I Status I IReactor I Coolant Pump 2Bl Status Reactor ICoolant IPump 2B2 IStatus I D I I I I I D ,I I I 3 I I I 0 to 800 amps Motor Current I 3 IOto800 I lamps I IMotor ICurrent 3 0 to 800 Motor la~ps Icurrent D 3 IO to 800 IMotor lamps Icurrent I N/h I I I I I N/A I I I NIA N/A I N/A I I I I I N/A I I I N/A I N/A I N/A I I I I I N/A I I I N/h N/A I N/A I I I I I Nlh I I I N/A I N/A NS I I I I I NS I NS NS Ves SAS Ves SAS Ves SAS I I.I.I SAS I I ves I veal veal I I I I I I I I I I I.I I veal veal I I I I I I I I I I I I I Yesl Yesl I I I I I I I I I I I vosl veal I I I I I I I I I I-24-1 S 3414 0

FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P.TYPE D DE 1 97 REV 3 Y SHEET" ES (Continued) 1?R 73, 1qg3 ITEM VARIABLE I cATz-TAG NO IDESCRIPTION ITYPE I GORY INSTRUMENT RANGE Oh I REQUIRE-I ENvIRUNMENTAL

'EIsMIc I I PowzR I DlsPLAY LocATIDN I scHFDULF/zxisTING I UIRED I MENT IoUALIFIcATIDN UALIFIcATIDN I REDUNDANczl sUP PLYI cg Tsc FQF I JnsTIFTlATIDN FT-01-4 IFlow Throuzhl D ISRV (V1201)I IFI&1-4 I I I FT-01-'5 I I IFI-01-5 I I IFT-01-1 I I I F1&1-I I I IPT-01-2 I I I FI&l-2 I Flow lhroushl D ISRV (V1202)I I Flow'Ihrouzhl D IPORV (V1474)I IFlow Throuzhl D IPORV (V1475)I Dll ILT-1110X Ipressuriser I I I Level I I (Narrow ILT-1110Y IRanse)LI-1110X LI-1110Y PR-1108/LR-1110X D10 I FT-01-3 I Flow'Ihroush I D I ISRV (V1200)I I I F1&1-3 2 IO to 100X IClosed-I I (Closed I Not Ito Open)IClosed 2 IO to 100X IClosed-I I (Closed INot Ito Open)IClosed 2 IO to 100X IClosed-I I (Closed I Not Ito Open)IClosed 2 IO to 100X IClosed-I I (Closed INot Ito Open)IClosed 2 IO to 100X IClosed-I I (Closed I Not I to Open)I Closed 1 I145.6 to ITop to I l331.8 IBottom linches WC 0 to 100X I Comply Comply Comply Comply Comply Comply Note 9 Note 18 Note 9 Note 18 Note 9 Note 18 Note 9 Note 18 Note 9 Note 18 Note 9 Note 9 Note 18 Note 18 Note 18 Note 11 Note 11 Note 11 Note 11 Note ll Note ll Note ll Note ll Note ll Note ll Note 11 Note I 1 Note ll Note ll Note ll N/A N/A N/A N/A N/A I LT-1110Y I I I LT-1110X I I I LI-1110Y I I I LT-J1.10X Iwote 6 INs I I I INote 6 I INS I I I INote 6 INS I INote 6 I INcl I I~I INote 6 I INs I I I INote 6 INs I I INote 6 lws I I INote 6 I INS I INote 6 I INS I I INote 6 INs I INote 2 I I SA I I I INote 2 I Isg I I I INote 2 I ISA I I I INote 2 I Isn I I I INote 2~I I sh I I I Yes Yes Yes SAS spns SAS spns Yes spns SAS SPDS SAS spns SAS SPDS SAS spns Ves I vesl I I I I-I I I I veal I (I I I-I I I I I I vesl I I I I I-I I I I I I veal I I I I I-I I I I I I veal I I I I-I I I I I veal'ro achieve a Ihigh quaittv lmeasuremenl

-Iqnalified lequinment was lused for tbts veslnonsafetv Imeasurement.

I-I I I Yes I I I-I I ves I I I-I I I ves I I I-I I I Yesl VeslIn addttion to I Ithe redundant I Isafetv grade veal Yeslnarrnw range, I la wide range I Innn-safetv

-I-Ichanne1 ts also lavailalle.

the I lwide range Ichannei meets I Itive requtred I Irange<cold--I-IcaIibrated).

I I I I-25-I S34w FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULA"P TYPE D HIDE 1.97 REV 3 Y SHEET" LFS (Continued)

VPPeRR 23, 1q83 VARIABLE INSTRUMENT RANGE QA CATE-I I REQUIRE-TAG NO DESCRIPTION TYPE GORY I EXISTING IRE UIRED I MENT ENVIRONMENTAL QUALIFICATION SEISMIC I I POwER I DisPLAY LorATIUN I srnpnmR/UALIFIcATIUN I REDUNDANcE I sUPPLY I~cR Tsr.EOF I JURYIFIrhvmN D12 IAM-943 I I I IAM-944 Heater Status Pressuriser I D 2 IO to 150 IElectric I Comply Current amps Note 18 Note 18 Note 11 Note ll N/A ARA ASH Yes RAS Yes RAR l veal veal I I I I I I Yes I Yes I I I I, I I I D13 I LT-1116 I Quench Tank I I Level LIA-1116 3 IO to 48 ITop to linches WC I Bottom I 0 to 100X I N/A N/A N/A N/h INote 4 l RAS INS I I I INote 4 I Yes INS I I I-I I lq.5X to qo.sx lof tnp tn Ibottom oe Iquench tank.I I Yesl YeslSbe range is D14 I I I I I I TE-1116 I Quench Tank I I Temp TIA-1116 3 IO'F to I350'F I I I50'F to l750'F N/A N/A INote 4 I SAS INS I I I INote 4 I Yes INR I Veal Yes I I I-I I I l I-I I I.I I I I I I I I I I'%e quench tank Idesign pressure lis Inn psig.lprior to lattaining this Ipressure, the Ilg inch rupture ldisc wil1 Iprnvide a Irelief path to lthe cnntain-lment Avm.Ilberefnre, anv Irelief from Ithe pressutiter Isafetv valves Iwil]be main-Itained belnw l10n psig and a Isaturation temp l less than the I3504p temp lrange of tbe Itank.I I I I I 0

FLORIDA PORE AND LIGHT ST LUCIS UNIT NO.2 REGULA IDE 1.97 REV 3"P UMMARY SHEET" TYPE D LES (Continued)

FR 23, 1qg3 ITEM TAG NO VARIABLE INSTRUMENT RANGE QA I PONER I DESCRIPTION I TYPE I GORY I EXISTING IRFRUIRED I MENT IOUALIPICATION I QUALIFICATION I REDUNDANCE I SUPPLY DIsPLAY LocATI0N I scHEDTlLF/

D15 IPT-1116 IQuench Tank I D I IPressure I I PIA-1116 3 IO to 100 IO to N/A I psig I Design IPressure I N/A N/A N/A INote 4 INS I INote 4 INS I SAS spns Ves I Yesl Veslnesign pressure I I its inn psig.I I I I-I--I I I I I l I D16 ILT-9013A ISteam I ICenerator I I Level 2Al I LT-9013B I (Narrow IRange)LT-9013C LT<013D LIC-9013A ILIC&013B I LIC&013C LIC-9013D LE&013D/IR-9023D 1 I 0 to 183 IFrom Tubel Comply I Inches ISheet to I I NC ISepara-Itors I 0 to 100X Note 9 Note 9 Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 Note 18 Note 11 Note ll Note ll Note ll Note 11 Note 11.Note ll Note 11.Note ll I LT-9n13D I I I LT-qnLBr.I I I LT-9ni3B I I I LV-qn13A I I I Lic-qnLBD I I I LIr.-9013r.

I I I LIC-9013B I I I LTc-9013A SAS Spns SAS SPDS SAS SPDS SAS SPDS Yes Ves Yes Yes INote 1 I IMA I I I INote 1 I IMB , I I I INote 1 IMr.I I I INote 1 I IMD I-I I INote 1 I IMA I I I INoto 1 I IMB I I I INote 1 I IMC I I'I INote 1 I V IMD I I I INote 1 I IMD I I I Veal I I I I I Veal I I I I I veal I I I I I Veal I-I I I I-I I I-I I I I-I I I I I Veal'ddition to Ithe redundant Isafetv grado Veslnarrow rance, la wide range Inon-safetv Veslchannel per lsteam renerator lis also avai1-Veslahle.Tho Iwide range Ichannel moets-lthe require~lrange (co1d Icalihrated).

-I I I-I I--I I I-I I l-27-1634M

FLORIDA PONER AND LIGHT ST LUCIE UNIT NO 2 REGULATOR~ep TYPE D V 1.97 REV 3 Y SHEET" (Continued)

FR 73,]983 ITEH TAG NO VARIABLE INSTRUMENT RA1CE?Ih chTE-I I REQUIRE-IENviRUNHENTAL I SEISHIc I I PONER I DESCRIPTION TYPE I GORY I EXISTING I UIRED I MENT IOUALIFICATION IOUALIFICATION I REDUNDANCE I SUppLY DIsPLAY LQRTIGN I scHFRHLl?/

cR Tsr.Eopl zosTIFIrATloN ILT&023A ISteem IGenerator ILevel 281 LT9023B l(Narrow Range)LT<023C ILT<023D I I ILIC&023A I I I I I I LIC"90238 I LIC<023C LIC-9023D LR-9013D/IR-9023D 1 I 0 to 183 Iprom Tubel I Inches ISheete tol I Nc ISepara-I tore I 0 to 100XI Comply Note 9 Note 9 Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 Note 18 Note ll Note ll Note ll Note ll Note ll Note Il Note 11 Note ll Note ll I LT-9023n I I I LT-sopsr.LT-9023R I LT-9023A I I=I LIC-9023D I I I LIr.-9023r.

I I I LIc-9023R I I I LIr-9023A INote 1 INA I INote 1 IHR I INote 1 Iw;I INote 1 IHD I INote 1 IHA I INote 1 IHR I INote 1 IHC I INote 1 IHn I INote 1 IHn I SAS spns SAS spn$SAS spns SAS SPDS Yee Ves Yes I, I Yes I-I I I I I I-I I I I I-I I I I I I-I I I I I<<-I I I-I I I IVee I VesITn addition to I I 1th'edundant I I lsafetv grade Ives I vealnarrnw range, I I Ia wide range I I Inon-sapetv IYee I Yeslchannel ner I I ISteam Generator I I lis also avail-IVes I Vealahle.The I I Iwide range I I Ichannel meets I-I--Ithe recurred I I Irange (cnld I I I calibrated)

.D17 PT-8013A ISteam IGenerator I l2Al Preesurel IPT&013B I I I PT&013C PT&013D IPI~013A PI&013B D 2 0 to 1200 IFrom ATH psia IPressure Ito 20X labove the ILowest ISafety I Valve ISetting Comply Note 9 I Note 9 I I Note 9 Note 9 Note 18 Note 18 Note ll Note ll I Note 11 Note 11 Note 11 Note 11 N/A INote 1 I IHA I I I INote 1 I INR I I I INote 1 I IHC I I I INote 1 I IHn I I I SAS spns SAS spns SAS SPDS INote 1 I IHA I I I'Note 1 I'es IHR I'Veal Veal I I I I I I I Yesl Yeel I I I I I I I Veal Veal I I I I I I I No I No I I I I I I I I-I-I I I I I I I I-I-I I I I 1534M PLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P TYPE D IDE 1.97 REV 3 Y SHEET" ES (Continued)

EH%FR 73 1SAB I ITEMI TAG NO.VARIABLE INSTRUMENT RANGE QA I POWER I DISPLAY LOCATTON I SCHFDULP/DESCRIPTION TYPE I GORY I EXISTING f UIRED I MENI'UALIFICATION IOUALIFICATION I REDUNDANCEI SUPPLYI CR TSC FOFI JUSTIFIChTION I P I&013C I I I PI&013D I IPR-8013D/

I 8023D I I PT-802 3A I I I PT&023B PT&023C PT&023D IPI&023A I I I PI&023B I I I PI 8023 C PI&023D PR&013D/I 8023D I I I Steam IGenerator l2A1 Pressurel I I I I I I I Steam IGenerator l2B1 Pressurel Ito 20X I labove thel ILowest ISafety IValve ISetting I I From ATM I 2 IO to 1200 Comply Ipsia IPressure I lto 20X I labove thel ILowest ISafety I Valve ISetting D I 2 IO to 1200 IFrom A'N I Comply I Ipsia Ipressure I Note 18 Note 18 Note 18 Note 9 Note 9 Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 Note 18 Note 11 Note ll Note 11 Note ll Note ll Note 11 Note 11 Note 11 Note 11 Note 11 Note 11 Note ll N/A N/A INote I I INC I I INote 1 I I I INote 1 I IHD I I I INote 1 I IMA I I~I INote 1'I f I I INote 1 I INC I I I INote l I IMD I I INote 1 I fxh I I I INote 1 I IMB I I I INote 1 I INC I I I INote 1 I IMD I I INote 1 I IND I Ves Yes Yea SAS SPDS SAS spns SAS SPDS Yes Ves Yes Yes Yes I--I-I I I I I--I-I l I I I-I-I I I I Vesl Yes!I f I I I I Veal Veaf I I I I I I I No I No I I I I I I I Veal Yesl I--I-I I I I-I-I I I I I--I-I I I I I I-I-I I I I I I I-I-I I I I I I I D18 FTWB-IB F1&8-IB Main Steam D Flow SG f2B1 (Safety Relief Valvel Positions)

I I PT&8-lh I Hain Steam D IPlow SG$2hlf l(safety I F1&8-lh IRelief Valvel IPositions) 2 IO to Closed-16 x 106 INot lib/hr IClosed 2 0 to Closed-6 x 106 Not lib/hr I Closed N/A N/A Note 17 Note 18 Note 17 Note 18 N/A N/A N/A N/A INote 6 I INS I I I INote 6 INR I I I INote B.I INS I I'I INote 6 I INs I I I SAS SPDS Yea SAS SPDS Yea Yeat I I--I I I Yes f I I-I I I vesfThe main steam fsafetv relieF Ivalve position-findication is fmonitored 4v lmoaaurina main Vealsteam I4ow.I I-I I 1-29-1 SHAH FLORIDA POHER AND LIGHT ST LUCIE UNIT NO 2 REGULATORY"P TYPE D V 1 97 REV3 Y SHEET" (Continued)

PR 2:4, 19A3 ITEM TAG NO VARIABLE CATE-DESCRIPTION TYPE I GORY INSTRUMENT RANGE Qh I REQUIRE-IEHVIROHMEHTAL I SEISMIC I I POHER I DISPLAY LOCATION I SCAHDULP/ExlsTING IREQUIRED I MENT IQUALIFIchTIQN IQUALIFIcATIQN I REDUHMNGEI sUPPLYI cR Tsc POFI JURTJPI5%YTON Main Feed-water Flow SG 42hl Hain Feed-water Flow SG f2B1 9021 D19 I FT<011 I I I I FIC-9011 I I I I FR-8011/I 9011 I I FT&021 I I I I PIC-9021 I I I FR&021/3 IO to IO to 110XI l6 x 106 IDesixn I lb/hr I Flow 3 IO to IO to 110XI 6 x 106 Design lb/hr Flow N/A N/A N/A N/A N/A N/A N/A N/A INote 6 IVS I INote 6 INS I INote 6 INS I INote 6 I INote 6 INS I INote 6 I SAS SPDS Yes Yes SAS I Sing I.Yes Yes Yes I I I-I I I-I I I Yes I I I-I I I-I I I Yes Yes ISince the ex-I5st5nX renal 5s Iclose to the Ireouire~rinse lof n to

>12-11HINote 2 I I sh I I I LIS-12-llA INote 2 Isn I INote 2 I SH a SAS SPDS SAS SPTIS Yes Yes Yes I vesl I I I I I vesl I I I I I-I I I I I I-I I I I-I I I I YeslThe range pro-lvlded covers 11.1Z to lnnt Yeslof bottom to ltop of the lstorsse tan>.-I I I-I I I-I I I D22 FT&7"lhl I Fr-07-lh I I I FR&7-lh I I Containment Spray Plow from Shut-down Cooling I Heat Ex-Ichanger 2A 2 I 0 to 5000 0 to 110Z IDesign IFlow gpm Comply Note 18 Note 18 Note 18 Note 18 Note ll Note ll'Note 11 Note ll INote 7 ISA I INote 2 I ISH I I I INote'2 I ISA I I I INote 2 I ISB I I I SAS ves Ves I vesl I.I I I I veal I I I I I-I I I I I-I I I I I Yeslnesign flow is l360n gpm.I Yes I I I-I I I-I I I-31-lS3hw 'PLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATO<

TON I FT&7-IBl I I I FT&7-1B2 I I I FI7-IB I I IFR-07-1B IContainment ISpray Flow Ifrom Shut-I down Cooling l Heat Ex-changer 2B 2 IO to 5000 IO to 110XI Igpm IDeeign I Flow Comply Note 18 Note 18 Note 18 Note 18 Note 11 Note ll Note ll Note ll N/A INote 2 lgn I INote 7 Ish I I INote 2 I I I I INote 7 I ISA I I I SAS SAS Yes ves I Yesl I I I I I veal I I I I I-I I I I I I-I I I I I Yes lnesign flow I is 36on gum.I Yes I I I-~I I I-I I I D23 ITE-25-1 I I ITE-25-2 TR-25-lA TE-25-3 TE-25-4 I TR-25-1A I I ITE-2s-s I I ITE-2s-6 I I I TR-25-1B TE-25-7 TE-25&I TR-25-1B I I 2 IO;F to I300 F IHeat Re-I D Imoval by thel Plant Specific I Containment IFan Cooler I2HVS-1A I I I I I Heat Re-Imoval by thel IContainment I Fan Cooler 2HVS-1B IHeat Re-D lmoval by thel IConteinment I I Fan Cooler l2HVS-1C 2 IO'F to IPlent I l300'F I Specific Heat Re-moval by the IConteinment I Fan Cooler l2HVS-1D 0 F to 300'F Plant Specific D 2 10'F to I Plant l300'F ISpecific N/A IRefer to IJustification I I I IRefer to I IJustification I Note 18 N/A N/A N/A N/A N/A I I I IRefer to IJustification I IRefer to IJustification I N/A N/A I I I I I I.I I Note 18 N/A IRefer to IJuetification I IRefer to IJustification Note 18 N/A I I I I I N/A N/A IRefer to I IJuetification I I I IRefer to I IJustification I Note 18 I ASA I I I ASA I I INote 2 ISA I I ASA I I I ASA I I INote 2 ISA I I ASB I I I ASH I I INote 2 ISB.I I ASH I I I ASB I I INote 2 ISB I Yes SAS Yes SAS Yes SAS I Yes I SAS I I-I I I I I I-I I.I I I I Yesl I I I I I-I I I I I I-I I I I I I Yesl I I I I I-I I I I I I-1 I I I I I Yesl I I-I I I Yesl I I I I-I The thermo-I couple ssssm-Ihlies have been-Ipurchesed as Inonsafetv leouipment. YeslThev do not I perform s Isafety function-Irluring or after lan accirlent. IAfter en-laccirlent, a11 I four contaln-Iment fan cool-Yesl ere ere starterl land remain op-Ieretional ~'ro-lachieve a high lquslltv mess-lurement, t>ese-llnons are wirerl Ias aseociaterl Issfetv CASA 4 YeslASB)~I I SAS CAlarm"-Ipoints onlv)Yes l I-32-1S34w PLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P TYPE D IDE 1.97 REV 3 Y SHEET" ES (Continued) FR 73, 1983 ITEM TAG NO VARIABLE INSTRUMENT RQSE Qh DEscRIPTI0N ITYPE I GQRY I EzIsTIHG IRE UIRED I MENT I UALIFIcATI0N IQUALIFIchTIQN I REDUNDANGEI sUPPLYI cR Tsr.EQFI JUsvIPIrh'%TAN D24 TE&7-3A IContainment I IAtmosphere ITemp TH&7-3B TI&7-3A 1R-07-3B/I 5B 2 IO'F to I450 F l40Fto I I400 F Comply Note 10 Note 10 Note 18 Note 18 Note ll Note ll Note ll Note ll N/A INote 2 I SA I INote 2 Isn I INote 2 ISA I INote 2 ISB I SAS SPDS Yes Yes I wo I I I I I I veal No IJustlfied for I interim nnera-ltinn (Sefer to Ves~Fn Packase I 139.)Subml t-Ited with-I inr FR~0.4o I Fquinment I List.--I I I D25 TE&7-5A I TEN 7-5B TI&7-5A I TR-07-3BI I 5B Containment Sump Water Temp O'P to 450 F 50'P to I 250 F Comply Note 9 Note 9 Note 18 Note 18 Note 11 Note 11 Note ll Note 13 NIA INote ISA I INote ISB I I Note ISA I INote ISB I I I 7 I I I 2 I I I SAR Ves 2 I~Ves I I I No I No I I I I I I I Vesl Yesl I I I I I-I I I I I I-I I I I D26 I PT-2212 I Charging I Flow l(Makeup PIA-2212 I Plow-in)2 0 to 150 IO to 110Z Igpm IDesign IFlow Comply Note 9 Note 18 Note 11 Note I]N/A INote 7 ISA I INote 2 ISA I SAS I Yesl Yes Design flow SPDS I I Iis 137 gnm.I I I Yes I-I-I I I I I I I D27 IPT-2202 ILetdown Flow-out FIA-2202 2 I 0 to 150 IO to 110ZI gpm IDesign I Flow Note 15 Note 18 NIA N/A INote 4 INS I INote 4 INS I SAS I Yesl Yeslnesign Flow SPDS I I Iis 13>gnm.I I I Ves I-I-I I I I I I-33-l 594M FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 RECULATO"P TYPE D V DE 1.97 REV 3 Y SHEET S (Continued) FR 23, Io83 ITEN TAC NO VARIABLE DESCRIPTION I TYPE INSTRUMENT EQR'E Qh I POWER I DISPLAY LOCATION I SCHEDTILR/ D28 ILT-2226 IVolume I IControl I ITank Level I LIC-2226 2 IO to 100 ITop to linches WC IBottom I I IO to 100X I N/A Note 15 Note 18 N/A N/A I Note 4 I SAS lws I I I INote 4 I Ves INS I I veal Yeslvbe ranee I I-Icnvers 14.1X tn I I IAS.qZ nf top tn I-I-Ibottom oF tan>.I I I I I I D29 TE-14-3A Component Cooling IWater Tem P TR-25-2A Ito ESF Sys-Item (CCW IHeat Ex-Ichanger 2A)I I TE-14-3B I Component I Cooling IWater Temp'IR-25-2B Ito ESF Sys-Item (CCW IHeat Rc-Ichanger 28)I I D 2 O'F to 300'P 2 10'F to l300'F l40'P to I200'F l40'F to I200 F N/A N/A Note 18 Note 18 N/A N/A N/A N/A I ASH I I INote 2 ISB I I I I ves I SAS I I I I ASA I I I I I INote 2 I Yes ISA 848 I-I I I I I I veal I I I I I--I I I veal I I I I I SAR Ca1arm I points onlv)I ves I I I I I-I I I ves I I I I I D30 IFT-14-lh I I I PIS-14-1A I FT-14-1B I I I PIS-14-1B IComponent I Cooling IWater Plow Ito ESP Sye-Item (CCW IHeat Ex" Ichanger 2A)I I I Component I Cooling IWater Plow Ito ESF Sys-Item (CCW IHeat Ex-I changer 28)I I 2 lo to I15,000 2 IO to I 115,000 IO to 110ZI gpmlDeeign I Flow IO to llOXI gpm I Design I Flow Comply Comply Note 18 Note 18 I I I I Note 18 I I I Note 18 I I Note 11 N/A I Note 11 I I Note ll I I I I N/A I I I I I Note ll I INote 2 I ISA I I I INote 2 I ISA I Note 2 I I SB I I I lwote 2 I ISB I I I I SAS SAS I Yesl I I I I I-I I I'I I I I I I I Yesl I I I I I-I I I I I I Yeslpesian flow is lg,sno np.I-I I I I I Yes I I I-I I I I I-34-1634M 0 FMRIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGUIATO"P TYPE D UIDE 1.97 REV 3 UMMARY SHEET" ES (Continued) FR 23, 1983 I ITEMI TAG No.VARIABLE I CATE-I DESCRIPTION IITPE I GORY INSTRUMENT JUICE Oh I REOUIRE-I ENVIRONMENTAL I SEISMIC I I PowER I DIsPLAY LochTIDN I scNFDULF/EXISTINC I UIRED I MENT I UALIFICATION I UALIPICATION I REDUNDANCEI SUPPLYI CR TSC FOP I JUSTIFICATION D31 ILT&610 I I I LIA&610 I I ILT&609 I I I LIAM 609 LT&608 ILIA&608 I I I LT&607 I I I LIA&607 IHigh Level D I Radioactive ILiquid Tank ILevel (Hold-I lup Tank 2A)I High Level I D Radioactive I ILiquid Tank I ILevel (Hold-I lup Tank 2B)I I I IHigh Level I D IRadioactive I ILiquid Tank I=ILevel (Hold-I lup Tank 2C)I I I High Level I D IRadioactive I ILiquid Tank I ILevel (Hold-I up Tank 2D)3 Io to 525 ITop to lunches WC IBotton I I IO to 100X I 0 to 525 inches WC I I ITop to IBottom I Io to 100X I I I I I 3 lo to 525 ITop to linches WC IBottom I I lo to loox I I I I I 3 Io to 525 ITop to linches WC IBottoa I I Io to 100X I N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A INote 4 I SAS INS I I I INote 4 I Yes INS I I I INote 4 I SAS I I INote 4 I Yes INS I I,I INote 4 I SAS INS I I I INote 4 I Yes I NB I I I INote 4 I SAS INs I I I INote 4 I Yes INS*I vesl I I I I-I I I I,I I Veal I I I I-I I I I I I Yesl I I I I I-I I I I I I Yesl I I-I I I Veslrhe range pro-Ivided covers IS.7X to oBX lof Tank Vn1ume.I I-ves I I I-I I I Yes I I-I-I I I Yes l I I-I I I D32 IPI-665o PI-6651 PI&652 IRadioactive I IGas Holdup I Tank Pres" Isure (Gas I Decay Tank I2A)I IRadioactive I IGas Holdup ITank Pres-lsure (Gas I Decay Tank I2B)I IRadioactive IGas Holdup ITank Pres-Isure (Gas Decay Tank 2C)0 to 300 psig 0 to 150XI N/A Design I Pressure I psig Design IPressure 3 Io to 300 Ipsig lo to 150XI I Design IPressure N/A 3 IO to 300 0 to 150XI N/A N/A I N/A N/A N/A I N/A N/A N/A N/A'/A N/A No I N/A I No N/A I No I No I I I I I I I I I I I I No I No I I I I I I I I I I I I I No I No I I I I I l I I I I I I ILocal indica-It4on is pro-Ivided.netai1s I<or this svstev lare provident 1n IChapter TT o<Ithe FSAR.I I I I I I I I I I I I I-35-1534M 0 FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATOR"P TYPE D V E 1.97 REV 3 RY SHEET" (Continued) PR 23, leR3 VARIABLE INSIUMEHT RANGE Oh I I GATE-I I REQUIRE-IEHYIRUNMEHTAL I sEIsNIG I'PowER I DIsPLAY LocATI0N I scH pDULH/D33 IVarious (See Note 7)IEmergency IVentilation IDamper IPosition Closed Status Closed Status 2 IOpen-IOpen-I Comply Note 7 Note ll Icatinn is nrn-Ivided in the lcnntrnl room, lsee Note 7 for lexcentlnns. I I I I I I I I I I I I I N/A INote 7 INote 7 INotelNntelnpen -Cloned Ish, sg I I7 I 7 I posit5on indi-D34 I Various (See Note 8)IStatus of IStandby IPower and IOther Energyl ISources I Important Ito Safety (Electric, Hydraulic, Pneumatic)(Voltages, ICurrents, IPressures) I 2 I Various IPlant I Note 8 IndicatorslSpecific Note 18 I Note 8 N/A N/A INote R INntelNotel IR IR I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I-36-IS34u FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY 1.97 REV 3"PARAMET Y SHEET" TYPE ABLES N 23, 1983 ITEM VARIABLE INSTRUMENT RANGE QA I POWER I DISPLAY LOCATION I SCHEDULE/El IRD-26~0 IContainment I=E I IArea Radia-I I Ition-High I I RD-26-41 I Range I I IRC-26-40 I I I RC-26-41 I I I RR-26-40 I I I RR-26-41 I I IRMs I Console I 1 Il R/hr ll R/hr I Comply Ito Ito I 108 R/hr I107 R/hr I N/A Note 9 Note 9 Note 18 Note 18 Note 18 Note 18 N/A Note 11 Note 11 Note ll Note 11 Note ll Note 11 N/A I RD-26&1 I I I RD-26%0 I I I RC-26-41 I I I RC-26%0 I I I RR-26-41 I I I RR-26%0 N/A INote 2 ISA I INote 2 ISB I INote 2 ISA I INote 2 ISB I INote 2 IsA I INote 2 ISB I INote 6 INS I SAS I Yesl Yesl I sPDs I I I I I I I I SAS I Yesl Yesl I SFDS I I Yes I I I Yes I I, I Yes I I Yes I I I Yes E2 I None IRadiation IExposure IRate (in-Iside build-Iings or lareas where I laccess is Irequired Ito service equipment important to safety)E 3 110 1 R/hrl N/A I to I I104 R/hr I N/A N/A N/A IFixed high Irange area I radiation mon-litors located lin areas im-Iportant to Isafety will not Ibe useful to an loperator. He Iwill be carry-ling a portable Ihigh range area Idetector on the Itrip to,at, and Ifrom the area limportant to Isafety.There lis a complete liow range area Iradiation mon-litoring system lin the RAB.I-37-1534M FLORIDA PONER AND LIGHT ST LUCIE UNIT NO.2 REGULATO"P TYPE E V E 1.97 REV 3 Y SHEET" S (Continued) FR 23, 1on3 ITEM VARIABLE INSTRUMENT RANGE Oh I CATE-I I REQUIRE-I ENVIRONMENTAL I SEISMIC I I POmm I DISPLAY LOCATION I SCNFDnLF/TAG N0 I DESCRIPTION ITYPE I GORY I EXISTING IRFA}UIRED I MENT I UALIFICATION IOUALIFICATION I REDUNDANCEI SUPPLYI CR.TSC FOF I JUSTIFICA>ION RE-26-90A I Containnent I lor Purge I Ef fluent-RE-26-90B I Noble Gas RE-26-90C IFY-26-90L IVent Flow I IRate I I I FY-26-90H I I I I RC-26-90 RR-26-90 RRR-26%0 RMS Console lo to I 150,000 Icfm IO to llOXI I Vent IDesign I Flow 2 I 10~I 10~luCi/cc to luCi/cc to ll05 ll05 luci/cc luci/cc N/A N/A Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 I N/A N/A N/A N/A N/A INote 6 I INS I I I INote 6 I INS I I I INote 6 I INs I I I INote 6 I INS I I I, INote 6 I INs I I I INote 6 I INS I I I lwote 6 I INS I I I INote 6 I INS I I I INote 6 I INs I I I Ves Yes-I-I I-I-I Yes Ves I I I I SAS I Veal Yesl SPDS I I I I I I SAS I Yesl Veal 81DS I I I I I I SAS I Veal Yesl I I I I I I SAS I Yesl Veal I I I I I I sAs I Yesl veal I I I I E4 IRE-26-90A IReactor I I Shield I I Building I RE-26&08 I Annulus-INoble Gas RE-26-90C FY-26&OL Vent Plow Rate I FY-26-90H I I I I I lo to I 150,000 Icfm IO to 110XI I Vent IDesign I Flow I I 2 I106 I10-6 N/A luCi/cc to luCi/cc tol I105 I104 I I uci/cc I uci/cc Note 18 I I Note 18 I I I Note 18 Note 18 I Note 18 N/A N/A INote 6 I INS I I I INote 6 I INs I I I INote 6 I INs I I I INote 6 I INS I I I Iwote 6 I INs'I I SAS I Yesl Veal SPDS I I I I I I SAS I Yesl Yesl SPDH I I I I I I S I Veal Veal I I I I I I SAS I Vesl Veal I I I I I I SAS I Veal Veal I I I I I I 1S34M PLORIDA POWER AND LIGHT ST LUCIE UNIT No.2 REGULATORY E 1.97 REV 3"P Y SHEET" TYPE E V (Continued) BER 23, 1983 TAG No.VARIABLE INSTRUMENT RANGE (IA I REqUIRE-I ENVIRONMENTAL I MENT I VALI FICATION IDESCRIPTION ITYPE I GORY I EXISTING sEIsMIc I I POWER,I UALIFICATION I REDUNDANCEI SUPPLYI DISPLAY LOCATION I SCHEDULE/CR TSC EOFI JUSTIFICATION IRC-26<<90 I I IRR-26-90 I I IRRR-26-9o I I IRMS IConsole I IReactor I Shield I Building I Annulus I I I N/A N/A Note 18 Note 18 Note 18 N/A N/A N/A N/A N/A INote 6 I INs I I I INote 6 I INS I I I INote 6 I INS I I I INote 6 I INS I Yes Yes Yes Yes E5 I RE-26-90A RE-26+OB I RE-26-90C I I IFY-26-90L I I I FY-26-90H Rc-26-90 IRR-26-90 I I I RRR-26-90 I I IRMs I Console I I Auxiliary E IBuilding. l(including lany Building Icontaining I Primary Sys-I Item Gases, I le.g., waste I Idecay tank)I INoble Gas 6 I IVent Flow IRate I Ilo 6 llo-6 uci/cc uci/cc lo to IO to 110XI I 150,000 I Vent Icfm I Design I Flow 2 luCi/cc to luci/cc tol I105 I103 N/A N/A Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 Note 18 N/A N/A N/A N/A N/A SAS SPDS SAS SAS SAS Yes Yes Yes Yes INote 6 I INs I I I INote 6 I INs I I I INote 6 I INS I I I INote 6 I INS I I I INote 6 I INS I I Note 6 I Ns I I INote 6 I INS I I I INote 6 I INS I INote 6'AS INS SPDS I I Yes I I I Yesl I I I I I Yesl I"I I I I Yesl I I I I I Yesl Yes l I I Yes I I I Yesl I I Yes I I I Yes I E6 I RE-26-11 I I IRMs!I Console ICondenser I Air I Removal I system IExhaust l(Noble Gas)I 2 Ilo 7 Ilo 6 luci/cc to luci/cc tol llo-2 llo5 I uci/cc I uci/cc N/A Note 18 Note 18 N/A N/A INote 4 INS I INote 6 INs I I SAS I SPDS Yes Yesl YeslVent flow lis normally Idirected to-Ithe plant Istack.I I-39-1534M FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATOR 1.97 REV 3"PARAMET Y SHEET" TYPE E V (Continued) ER 23, 1983 ITEM TAG NO.VARIABLE INSTRUMENT RANGE QA I powER I DESCRIPTION TYPE I GORY I EXISTING I UIRED MENT I UALIFICATION I UALIFICATION I REDUNDANCE I SUPPLY I DISPLAY LOCATION I SCHEDULE/E7 IRE-26-90A I I I RE-26&OB I I I RE-26-9 0C I Common Plant l E IVent or I IMultipurposel IVent Dis-I Icharging anyl lof above I Releases I l(if contain"I Iment purge I lie included)I I Noble Ges 2 I 10&I 10-6 N/A luCi/cc to luCi/cc tol I IOS I 103 I luCi/cc luCi/cc 10-6 luci/cc tol 104 uCi/cc Note 18 Note 18 Note 18 N/A N/A INote 6 INS I INote 6 INS I INote 6 INS SAS I Yesl Yesl sPDs I I I I I I SAS I Yesl Yesl sPDs I I I I I I SAS I Yesl Yesl'FY-26-90L I I I FY-26-90H I I IRC-26-90 I I I RR-26-90 RRR-26-90 IRMs I Console I Vent Flow Rate IO to ISO,OOO Icfm IO to 110X I Vent IDesign I Flow N/A Note 18 Note 18 Note 18 Note 18 Note 18 N/A N/A N/A INote 6 I INS I I I INote 6 I INs I I I INote 6 I INs I I I INote 6 I INs I I I INote 6 I INs I I I INote 6 I INS I SAS SAS Yes Yes Yes Yes I I Yesl I I I I I Yesl Yes I I I Yes I E8 I RE-26-71 I I.I RE-26-72 RE-26-73 RMS Console IVent from E'I Steam Gen-lerator I Safety I Relief Valves or Atmospheric Dump Valves I (Noble Gas)I Il mR/hr tol10 1 IIOS mR/hr luCi/cc tol Ilo'luCi/cc l(Dura-Ition of Ireleases I lin sec-I londs and I Imase of I steam per unit time)N/A Note 16 Note 16 Note 16 Note 18 N/A N/A INote 4 I INs I I I INote 4 INS I I I INote 4 I INS I INote 6 INS SAS I I I SAS I I I SAS I Yes Yes l Yes l Existing range I Icomplies with I Ithe required Yesl Yeslrange. I I In operation, I Ithe radiation Yesl Yeslemanating from Ithe main steam lline is mea"-Isured in mR/hr, Iwith hand Icalculations Iconverting the Ireadings to the lappropriate luCi/cc reading.I-40-1534M FLORIDA PONER AND LIGHT ST LUCIE UNIT NO 2 i REGULATO"P TYPE E DE 1.97 REV 3 Y SHEET" ES (Continued) FR 23~JoR3 INSTRUMENT RANGE Qh VARIABLE I I ITEM I TAG NO I DESCRIPTION CATE-I TYPE I GORY I EXISTING I REqUIRE-I ENVIRONMENTAL I SEISMIC I I POWER I DISPLAY LOCATION I SCHFDHLl?/ UIRED I MENT I UALIFICATION 'I UALIFICATION I REDUNDANCEI SUPPLYI CR TSC EOF I JUSTIFICA'TJON E9 IRE-26&9A IAll Other I IIdentified I I Release IRE-2669B IPoints~I INoble Gas I IRE-26-69C I I I FY-26&9 I Vent Flow I IRate I I I RE-26-70A I I I RE-26-70B I I RE-26-70C I I I PY-26-70 I I I RC-2~9 I I IRC-26-70 I I I RR-26-69 RR-26-70'RRR-26-69 I I I.I I I RRR-26-70 I RMS Console I RE-26-12C I 10-6 I 10-6 luCi/cc to luCi/cc tol IXO6 I102 luCi/cc luCi/cc IO to IO to 110XI l36,000 cfmlVent IDesi8n I FLow 10 6 I10-6 2 luCifcc to luCi/cc tol llo-2 1102 luCi/cc Iuci/cc I I I I Comply N/A N/A Note 18 Note 11 N/A Note 18 Note 11 Note 18 Note 11 Note 18 Note ll Note 18 Note ll Note 18 Note 11 Note 18 Note 11 Note 18 Note ll Note 18 I Note ll Note 18 Note 18 I Note 18 Note 11 Note 18 Note ll I Note 18 Note 11 I N/A I I Note 18 I N/A I I N/A I.N/A I I N/A-41-Note ll I I I Note 11 Iwote p I I sh I I I INote 7 I ISA I I INote 2 I IsA I I I INote 2 I I SA I I INote 7 I ISB I I I INote 2 I I I I INote P I ISB I I I INote 2 I ISB I I INote 2 I IsA I I I INote 7 I ISB I I I INote 7 I ISA I I I INote 2 I ISH I I I INote>I ISA I I I INote 2 I ISB I INote 6 I INS I INote 4 INS I I I I SAS SPDS SAS SPDS SAS SPDS SAS SPDS SAS SAS Yes Yes Yes Yes SAS SPDS Veal Veal I I I I I I I Veal Vesl I I I I I I I veal veal I I I I I I I Veal Veal I I I I I I I Veal Veal I I I I I I I Yesl Veal I I I I I I I Yesl Veal I I I I I I I Yesl Yesl I I I I I I I-I-I I I I I I I I-I-I I I I I I I I-I-I I I I I I I I-I-I I I I I I I I-I-I I I I I I I I-I-I I.I-I I I I-I-I I I I I I I I VesI VesIFHR stack is I I?diverted to I I Ip1ant stack I I Ion hinh I I Irad?ation. I I I I s34+ FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"P TYPE E V 1.97 REV 3 Y SHEET" (Continued) N.y3, loR3 TAG NO.VARIABLE I I DESCRIPTION I TYPE INSTRUMENT RANGE Qh CATE-I I REQUIRE-IEHVIRONMENTAL I SEISMIC I I PowER I DIsPLAY LochTIoN I srHFDHLE/G0RY I ExlsTING IRE UIRED I MENT I UALIFIcATI0N IQUALIFIcATIUN I REDUNDANGEI sUPPLYI cR Tsr.FoFI JUm'IFlrATTON Elo I EFF-PART EFF-HALO IParticulatesl E land Halogensl I I I All identi-Ified Plant IRelease IPoints (ex-Icept steam Igenerator Isafety re-llief valves I lor atmo-Ispheric leteam dump Ivalves and Icondenser I lair removal I system ex-haust).Sampling with Onsite I Analysis ICapability I 3 I10 3 I10 3 I luCi/cc to luCi/cc tol l102 l102 luci/cc luci/cc IO to 110XI I Vent I Design I Flow N/A N/A N/A N/A N/A I No I I No I I I I I I No I I No I I I I I I I I I I I I I I I I I I I I I No I I No I Igee other I Ff fluent I Pa thwave I I I I I I I I I I I I I Ell!Portable Iby FP&L I Airborne I Radio-halo-Igene and Particulateel (portable sampling with oneite I I analysis I Icapability) I I 3 I10 9 I10 9 luCi/cc to luCi/cc tol I10 3 I10 3 luCi/cc luCi/cc N/A N/A I-N/A N/h I I I I I I I I I I N/A I I I I I I I I I I I I I I I I N/A I N/Al N/AI I I I I I I I I I I I I I I I I I I I I I I I I I I I E12 IPortable Iby PP&L I I IPlant and I Environs IRadiation l(portable linetrumen-Itation)I10 R/hr I10 3 R/hrl lto lto I ll04 R/hr I104 R/hr,l Iphotons llo-3 Irads/hr lto 104 Irads/hr, Ibeta ra-Idiatione I land low lenergy Iphotons I N/A I N/A I N/A I N/A I I I I I N/A I I I I I N/A I I I I I I I N/Al I I I I I I I I I I I I I N/A I I I I I I I I I I l S34N FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATOR"P TYPE E V E 1.97 REV 3 Y SHEET" (Continued) PR 23'qgg N VARIABLE I TAG NO I DESCRIPTION I TYPE INSIRUMENT RANGE Qh CATE-I I REQUIRE-IENVIRONNEHTAL I SEISNIC I I POWER I DISPLAY LOCATION I SCNpDULE/GORY I EXISTING I UIRED I NEHT I UALIFICATION I UALIFICATION I REDUNDANCEI SUPPLYI CR TSC EOFI JUSTIFICATION E13 IPortable IPlant and Iby PP&L IEnvirons I Radioactiv lity (por-I table linstrumen-I tation)I E 3 I Isotopic IAnalysis I Isotopic I N/A IAnalysis I N/A N/A N/A I N/A I N/A I N/A~N/Al I I I I I I WD10-DL llO-meter I Wind IDirection WD10-HW I I I I I WD60-DL 60-meter IWind Direc-I tion IWD60-HW I I I IO to 540'accuracy I Iwit?I&Ide flec-Ition of I 10').I Starting I ISpeed I Iless thanl I0.4 mpe l(1.0 lmph).I Damping Iratio Igreater Ithan or lequal to I l0.4, I Idelay I Idietance I llese thanl lor equal I lto I l2 meters.l I I Same ae IAbove N/A 3 IO'o 540'IO to 360'I N/A I (+.5'N/A N/A N/A N/A N/A I I I I I I INote 4 I SAS INS I I I INote 4 I SAS INS I I I N/A INote 4 I SAS INS I I I, INote 4 I SAS INS-I>eel Yeslsee Note>4.I I I I I I I Yesl Yesl I I I I I I I I I I I I I I I I I I I I I I I, I I I I I I'I I I I I I I I I I I I I I I I I I I I I I I I Yeel veeISee Note 14.I I I I I I I Yeel Teel I I I I I I-43-1S34+ FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 RECULATOR"P TYPE E V E 1.97 REV 3 Y SHEET" (Continued) ER 23, loH3 VARIABLE INSTRUMENT RANGE Qh I CATE-)I REQUIRE-IENVIRONMENTAL I SEISMIC I I POWER.I DISPLAY rachel UIRED I MENT I QUALIFICATION I QUALIFICATION I REDUNDANCE I SUPPLY I CR ITEM I TAG NO I DESCRIPTION I TYPE GORY I EZISTING TSC ON I EOFI ZnSVIFrCAVION SCmmULE/WS60-DL IWS60-HW l60~eter Wind Speed E15 WS10-DL I 10meter Wind Speed IWS10-HW I I I I I I 3 IO to 120 mph I 3 lo to I I120 mph I lo to I I22 mps I l(50 mph)I I+0.2 mpsl l70.5 mph)l Iaccuracy I I for I Ispeeds I Iless thanl l2 mps I l(5 mph), I IIOZ for I lspeeds inl lexcess ofl l2 mps I l(5 mph), I I@1th a I Istarting I I threshold I lof less I Ithan 0.4 I Imps (1.0 I lmph)and la dis-Itance Iconstant Inot to I lexceed l2 meters.I ISame as lhbove N/A N/A N/A I N/A I I N/A I I I N/h N/A I N/A INote 4 I INS I I I INote 4 I INS I I I I, I'.I I I I I I I I I I I I I INote 4 I INS I I I INote 4 I INS I I I I I I SAS SAS I Yesl YeslSee ante>4.I I I I I I I YesI Yesl I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I SAS I I I I I I I Yesl Yesl I I I I I I I I I I I I I I-I SAS I Yesl YesISee Note 14.-44-I S%4M F LORIDA POHER AND LIGHT ST LUCIE UNIT NO 2 REGULATOR"P TYPE E V E 1.97 REV 3 Y SHEET" ,S (Continued) FR 23, ln83 ITZH VARIABLE INSTRUMENT RANGE Oh I POHER I nlsPLAY LochTIDN I scHPDULP/TAG No IDEscRIPTIUN ITYPE I G0RY I ExIsTIHG I UIRED I HEHT I UALIFIchTIoN IQUALIFIcATI0N I REDUNDANcFI sUPPLY cR Tsc Popl Jlib'JPIIÃrIDN E16 I Inmet ICentral lnata I Station I Estimation lof Atmo-Ispheric IStability I-15'F to ll5'F-IThis is lacquired Iby taking Ithe dif-Iference Ibetween Ithe 60-Imeter tern land the I10~eter Itemp.IBased on I Ivertical I Itempera-I Iture dif-I I ference Ifrom Iprimary Imeteoro-llogical plsystem, I-5 C to I 10'C l(-9'F to I I18'F)andi I+0.15 C I laccuracy I Iper 50-I Imeter I lintervals I I(+0.3'F I laccuracy I Iper 164-I foot linter-Ivals)or lanalogousl Irange forl lalterna-I Itive I lstabilityl lestimatesl N/A N/A N/A N/A I I Note 4 I MS SAS I Yesl Yeslgee Nnte l~.I I I I I I I I I I I I I I I I I I I I I I I E17hl I I IPC&h Primary I Coolant I IGross Activity PC-XE-133 Xenon PC-I-131 Iodine Il uCi/ml Ito 110 Ci/ml I ll uCi/ml Ito I10 Ci/ml I ll uCi/ml Ito I10 Ci/ml I Il uCi/ml Ito ll0 Ci/ml I I Isotopic I Analysis I I IIsotopic IAnalysis I I N/A N/A N/A N/A N/A N/A N/A NIA N/A NIA I N/A NIA I NIA N/A I N/A SAS SAS I I I<ariel les for I I I Item F174 are I I lmanuall v 1nput-I Yesl Yeslted tn SAS.I I I I I I I I I I Yesl veal I I I I I I I I I I Yesl Yesl I I I I I I I I I-45-1$94'k FLORIDA POWER AND LIGHT ST LUCIE IJNIT No.2 RZGULATO"P TYPE E V DE 1.97 REV 3 Y SHEET" S (Continued) ER 23, l,og3 VARIABLE TAG No DESCRIPTION CATE-GORY EXISTING I vIRED INSTRUMENT RANGE OA Rzqvizz-IENYIRONNENTAL I szrsNIC I I POWER I DISPLAY LOTION I SCHFDULF/HENT I UALIFICATION 'IOUALIFICATION I RFDUNDANCEI SUPPLYI CR TSC EOF I.lUSTIFDWHON PC-CS-134 Cesium IPC-B IPCWL I Boron IContent I I I Chloride IContent PC-H2 PCS Dissolved Hydrogen Dissolved loxygen PC-PH PH PC-C~O ICobalt 3 3 E 3 Il uCi/ml Ito 110 Ci/ml I Isotopic I Analysis I N/A 1 uCi/ml to Ilo Ci/ml I IO to 25 N/A Isotopic Analysis lo 0 to 100X Total Gas lo to 2000 A Icc (STP)/I N/Ikg IO to 20=Ippm Iby Volume IO to 5 Ippm Io to 10 Ippm IO to 20 Ippm 0 to 100Z I I 1 to 13 Il to 13 PH IPH N/A N/A x to N/A llo ppm l6000 ppm I I I I I I15 to Inf Io to 20 N/A Ippm Ippm I I I N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A I N/A I N/h N/A N/A N/A N/A N/A N/A I N/A N/A N/A N/A N/A N/A N/A I SAS SAS SAS SAS SAS SAS I Yesl Veslvarlables for I I Ttem F37A aro I I Imanual l v innut-I I Iron tn sAS.I Yesl Yesl I I I I I I I.I I Yesl Yesl I I I I I I I I I I Yesl Yesl I I I I I I I I I Yesl Yesl I I I I I I I Veal Yesl I I I I I I-I I I I I I I I I I Yesl Yesl I I I I I E17B S-GA I Sump Gross Activity S-I-131 IIodine S-XE-133 IXenon I S-Co-60 I Cobalt I I I 3 ll uCi/ml to 10 Ci/ml ll uCi/ml Ito Ilo Ci/ml I ll uCi/ml to 10 Ci/ml ll uCi/ml Ito llo Ci/ml I 1 uCi/ml Ito 110 Ci/ml I IIsotopic IAnalysis I I IIsotopic IAnalysis I I I Isotopic IAnalysis I I I N/A I I I I N/A I N/A I I I I N/A I I I I I I N/A I N/A I N/A N/A I I I N/A I I N/A I N/A I N/A I I I N/A I N/A N/A I NIA I I I N/A N/A N/A I N/A I SAS SAS I I IVariables for I I IItem R17n are I Yesl veslmanusllv innut-I I Ited tn SAS.I I I I I I I Yesl Yesl I I I I I I I I I I Yesl Veal I I I I I I I I I I Yesl Veal I I I I I I I I I-46-J a%4M FLORIDA POHER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY E 1.97 REV 3"P Y SHEET" TYPE E V (Continued) FR 73, 1cR3 ITEN VARIABLE INSTRUNEHT RANGE QA I CATE-I I REQUIRE-IENVIRONMENTAL I SEISNIC I I POWER I DISPLAY LOCATION I SCHFDULF/TAG No, IDEscRIPTIDN ITYPE I GQRY I EzlsTING I UIRED I HENT I UALIFIcATI0N I UALIFIcATIDN I REDUNDANcEI sUPPLYI GR vsc Fovl JUsrIFTchvTON S-B I S-CL I S-PH IBoron IContent I I IChloride IContent I I IPH I S-CS-134 I Cesium ll uCi/ml I Isotopic Ito IAnalysis I10 Ci/ml I I I IOto25x IOto I 10 ppm l6000 ppm I I I I I15 to Inf IO to 20 lppm Ippm I I I I Il to 13 ll to 13 IPH IPH I N/A I I I I N/A I N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A SAS SAS SAS HAS I veal I I I I I I veal I I I I I I I veal I I I I I.I I veal I I I I Vesluarlahles for ITtem v17R are Imanually (nnut-Ite<to RAS.ves 1 I.I I Yes I I I I ves 1 I I CA-H2 Containment IAir Hydrogen Content CAW2 Oxygen Content CA-ZE-133 I Xenon I CA-I"131 I iodine ICARUS Cesium I CA&TH I Others E 3 0 to 10 Vol-Z 0 to 30 Vol-Z 10 6 to 106 luCi/ml I ll0-10 to I 105 luCi/ml 10-10 to 103 luCi/ml I I10-6 to I103 luCi/ml I 0 to 10 IVol-Z IO to 30 IVol-X I I IIsoto i p C I Analysis I I I Isotopic IAnalysis I I I Isotopic IAnalysis I I IIsotopic IAnalysis I I N/A N/A N/A I N/A I N/A I N/A I I I N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A.N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A I I N/A I N/A I I I N/A I N/A SAS SAS No I I I.I I I I veal I I I I I veal I I I I I I vesl I I I I I I I veal I I I I I I I veal I I I I I I I No I I I I I I I'1Variahles fnr ITtem F1R are lmanuallv lnnut-Yeslted to SAS.I I veal I I I veal ves I I I I veal I I I No I I I I PLORIDA PONER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"P E i+97 REV 3 Y SHEET" S FR 23, I'N3 Note 1: 120 VAC, Class 1E, uninterruptable power supply.Note 2: 120 VAC, Class 1E, offsite power backed by an emergency diesel generator. Note 3: 125 VDC, Class 1E battery.Note 4: 120 VAC, non-Class 1E offsite power.Note 5: 125 VDC, non-Class lE battery.Note 6: 120 VAC, non-Class 1E, uninterruptable power supply.Note 7: Emergency ventilation dampers: TAG NUMBER ZS>>25-18, 19 ZS-25-120, 121 ZS-25-122, 123 ZS-25-118, 119 ZS-25-36, 37 ZS"25-38, 39 ZS-25%0, 41 ZS-25-42, 43 ZS-25%6, 87 ZS-25-90, 91 ZS-25%4, 95 ZS-25-116, 117 ZS-25&4, 45 ZS-2~6, 47 ZS-25%8, 49 ZS-25-50, 51 D-1 (No CR indication, see Note 19)D-2 (No CR indication, see Note 19)D-3 (No CR indication, see Not'e 19)D-4 (No CR indication, see Note 19)D-5A D-5B D-6B D-7A (No CR indication, see Note 19)D-7B (No CR indication, see Note l9)D-BA (No CR indication, see Note 19)D-8B (No CR indication, see Note 19)D-9A D-9B D-12A D-12B Note 9 Note 9 Note 9 Note 9 Note 9 Note 9 Note 9 Note 9 Note 18 Note 18 Note 9 Note o Note 9 Note 9 Note 18 Note 18 SAS TSC RAP No No No No Yes Yes No No No Yes Yes Yes-48-JS34w FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 RECULATO"P N DE 1~97 REV 3 Y SHEET" ntinued)FR 23>>loA3 Note 7: Emergency Ventilation Dampers: (Continued) TAG NUMBER ZS-25-52, 53 ZS-25-54, 55 ZS-25-56, 57 ZS-25-58, 59 ZS-25-24, 25 ZS-25-72, 73 ZS-25-26, 27 ZS-25-28, 29 D-13 D-14 D-15 D-16 D-17A D-17B D-18 D-19 Note 9 Note 9 Note 18 Note 1A Note 18 Note 18 Note 18 Note 18 SAS vSC Fnp No No No Yes Yes Yes Note 8s Ihe following status of Standby.Power and Other Energy Sources Important to Safety are monitored in the control room: 1-Startup/Standby Tranaformers-a-Transformer primary winding voltage (230kV East-Vest Bus)-249 kV Recorder/888**, DVM/AAA**()b-Primary and Secondary breakers-status lights (closed-open) <<(SSB-2Al, SSB-281)*"(.)c-Transformer secondary winding (4160V Bus 2A2&2B2)voltage (VS-916, VS-917)e*, Bus energizeR lights~Ter 916>>TT;917)**, current (AS-916, AS-917)**, Watt hours (WHM-916, WHM-917)** 2-Emergency onsite 4160V 2A3, 2B3&2AB Buses-a-Bus Tie Breakers Status light (BT2A3-2AB, BT2B3-2AB)*(2) b-4160V Bus 2AB voltage, current&status (VM-942, AM-942, IL<<942)*(2) c-4160V Bus 2A3&283 voltage, current&status (VM-954, VM-964, IL-954, IL-964, AM936, AM937)"()3-Emergency onsite 480V Bus 2A2, 2B2&2AB a-Incoming feeder breaker status lights (open-close)(FB2A1, pB2A2, FB2A5, FB7B1>>FBZB2, FAZB5, BT7A7-7AA>> nvyA7-7AA, BT2AB 2A2,BT2AB 282)*(2)-49-15 94M FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY"p N 1,97 REV 3 Y SHEET" inued)N FR 23, Iqn3 C Note 8: 4-Emergency onsite DieselWenerators 2A&2B (Continued) a-Current (~55, AH-965)*()b-Voltage (VM-1606D, VH-1616D)*()c-Frequency (FH-1606, FH-1616)*d-Vers (VARM-1606, VARH-1616)* e-Watts (W-REC-1606, W-REC-1616)* f-Watt hours (WHH-955D, WHH-965D)" g-Diesel generator loading lights-4160V feeders (IL-996 A,-B,-C,-D,-F.,-P,-G,-N,-I, IL-9q7A,-B,-C,-D,-E,-N,-P, IT;qq<,-C)* 480V feeders (IL-996K,-L,-M,-P,-Q,-R,-T, IL-9978,-T,-U,-V,-Q,-R,-H,-N, IL-998D,-E)* 5-125V dc Batteries a-Voltage (VH-1001, VH-1002, VM999, VM1805)*()(IL-1001, IL-1002)*b-Battery charges current (AM-1001, AH-1002)*c-Battery high discharge rate alarms (AM-1801, AM-1802)*(1) (2)d-Battery breakers in open positions alarms (BCB2A, BCB2B)**()()e-Ground alarms (BGS2A, BGS2B, BGS2C, BGS2D, BGS2AB)**(1) (2)6-120V ac non-interruptible instrument buses MA, MB, MC&MD control room annunciation via local annunciator**(1) a-Low dc voltage b-High dc voltage c-Low ac voltage d-Out of frequency e-Ground f-dc breaker trip g-Status indication for SAS (bus-MA, bus-HB, bus-MC, bus-HD)()*-Comply with IEEE-344-1975 for seismic qualification, also comply with OA requirement.

-the isolation devices are provided between annunciators and an associated Class lg actuating devices.(>>-SAS, TSC, EOF-50-)534M FLORIDA POWER AND LIGHT ST LUCIE UNIT NO.2 REGULATORY Wp NOTES 1+97 REV 3 Y SHEET" inued)N 73, lqg3 Note 9: Comply with 10CFRSOA9 and NUREG-0588 Category 1 (IEEE-323-1974) for environmental qualification. Note 10: Will comply with 10CFR50.49 and NUREG&588 Category 1 (IREE-323-1974) for environmental qual tficatton. Note ll: Comply with IEEE-344-1975 for seismic qualification. Note 12: Will comply with IEEE-344-1975 for seismic qualification. Note 13: 6~eter temperature and 10~eter temperature is fed to the Inmet Central Data Station (Untt J Control Room)vta FN stgnal.transmtsston (Analog signal provided to SAS).Also, a future telephone line link will provide a redundant input to SAS.A differential amp]ifter accepts the two signals and produces a voltage which represents differential temperature. This differential temperature ts recorded in the Central Data Station (Unit 1 Control Roon).Note 14: wind direction and speed is fed to the Inmet central Data station (Unit 1 control Room)via FN stgnal transmission (Analog stgnal provided to SAS).Also, a future telephone line link will provide a redundant input to SAS.At the Central Data Station (Unit 1 Control Room), wind direction and speed are recorded on analog recorders. Note 15: The sensor is located in a harsh environment post accident.However, it is not required to perform a safetv function oi mitigate the consequences of an accident.It is only provided for plant surveillance during normal operation. High quality instrumentatton is utilized.Note 16: The sensor is located in a harsh environment only during MSLH-trestle. However, it is not reuulred to perform a safetv hmctton or mitigate the consequences of an accident.It is only provided for plant surveillance. Note 17: The sensor is located in a harsh environment post accident.The equipment is provided for plant surveillance during nnrma1 oneration and non-accident transients. The type of equipment utilized has been generically qualified to a lesser environment than lnmontainment accident environment for this plant.Note 18: The equipment is located in a mild environment and will withstand its service location conditions. Note 19: The damper limit switches will be installed to provide Control Room indication by the end of the first refueling outage.-51-]5'44H SECTION VI LIST OP SYSTEMS REQUIRING ADDITIONS, MODIPICATIONS OR ANALYSIS The following is a list of the St.Lucie 2 instrument system, which as a result of this evaluation, requires addition, modification or analysis.1.The following items will be qualified by the end of the first refueling outage.r Item A-2 Reactor Coolant System Cold Leg Water Temperature RTD's Item A-3 Reactor Coolant System Hot Leg Water Temperature RTD's Item B-9 Heated Junction Thermocouples (ICCS)Item B-14 Containment Isolation valve position indication (only for valves justified for interim operation) Item C-1 Core Exit Thermocouples (IGCS)Item D-24 Containment Atmosphere Temperature RTD's.These items have been justified for interim operation.(Refer to packages submitted with 10 CFR 50.49 equipment list).2.Item D-33 The following emergency ventilation damper limit switches will be wired to the existing control room indicating lights by the end of the first refueling outage.D-1, D-2, D-3, D-4, D-VA, D-7B, D-8A and D-8B.The limit switches are fully qualified and the wiring will be routed in safety related cable tray system.3.Item C-2 Radioactivity Concentration Level in Primary Coolant.A study regarding equipment availability wiD be completed by-December 1983. SECTION VII REPERENCES REFERENCES Regulatory Guide 1.97, Rev.3 10 CFR 50.49 Regulatory Guide 1.89 Regulatory Guide 1.100 NUREG 0737, Supplement 1 NUREG 0588 IEEE-323, 1974 IEEE-344, 1975 SECTION VIII CONCLUSIONS CONCLUSIONS 1.Based on the information presented in this report, St.Lucie Plant Unit 02 will conform with the requirements of Reg.Guide 1.97 Rev.3 by~rend of the first refueling outage.2.For some instrumentation which does not fully comply with the requirement of Reg.Guide 1.97, Rev.3, a justification has been provided (Section V). ~E/e