WCAP-17252-NP, Rev. 2, Acoustic Loads Definition for the Monticello Steam Dryer Replacement Project
ML12207A544
Person / Time
Site: Monticello Xcel Energy icon.png
Issue date: 05/31/2012
From: Longoni G
Westinghouse
To:
Office of Nuclear Reactor Regulation
References
L-MT-12-056, TAC MD9990 WCAP-17252-NP, Rev 2
Download: ML12207A544 (26)


Text

L-MT-12-056ENCLOSURE 11WESTINGHOUSE REPORT, WCAP-17252-NP, REVISION 2ACOUSTIC LOADS DEFINITION FORTHE MONTICELLO STEAM DRYER REPLACEMENT PROJECT25 pages follow Westinghouse Non-Proprietary Class 3WCAP-17252-NP May 201,Revision 2Acoustic Loads Definition forthe Monticello Steam DryerReplacement ProjectWestinghouse WESTINGHOUSE NON-PROPRIETARY CLASS 3WCAP-17252-NPRevision 2Acoustic Loads Definition for the Monticello Steam DryerReplacement ProjectAuthor: Gianluca Longoni,Acoustics & Structural AnalysisReviewer: David A. Suddaby*Acoustics & Structural AnalysisMay 2012Approved: David R. Forsyth*, ManagerAcoustics & Structural Analysis*Electronically approved records are authenticated in the electronic document management system.Westinghouse Electric Company LLC1000 Westinghouse DriveCranberry Township, PA 16066© 2012 Westinghouse Electric Company LLCAll Rights ReservedWCAP- I7252-NP.doc-052512 ivTABLE OF CONTENTSLIST OF TABLES ........................................................................................................................................ vLIST OF FIGURES ..................................................................................................................................... viACRONYM S .............................................................................................................................................. vii1 EXECUTIVE SUM M A RY ........................................................................................................... 1-12 [ ]a ............................... 2-12.1 INTRODUCTION ........................................................................................................... 2-12.2 [] .............................................. 2-22.3 [A .................................................................................................................. 2-53 [........................................................................................ 3 -13.1 INTRODUCTION ........................................................................................................... 3-13.2 [] .................................... 3-23.3 [] ........................................................................ 3-24 [ ] .... 4-15 RE FERENCES ............................................................................................................................. 5-1WCAP- 17252-NPMay 2012Revision 2 VTable 3-1Table 3-2Table 3-3Table 3-4Table 4-1I[LIST OF TABLESp] b,.. .................................................................................. 3-2] b,c .......................................................... 3-3]p. b, c ......................................................... 3-3]ab, c ..................................................... 4-] cb, ....................................................................... 4 -1WCAP-17252-NPMay 2012Revision 2 viLIST OF FIGURESFigure 2-1Figure 2-2Figure 2-3Figure 2-4Figure 2-5Figure 2-6 [Figure 3-1Figure 4-1 [Figure 4-2Figure 4-3 [Figure 4-4 []b .................................................................... 2 -2.b ..................................................................... 2-3]b ....................................................................... 2 -4]b ............................................................................. 2 -4......................................................................... 2 -5]a, b .................................................................. 2 -933 ........................................................................................... 3 -1]a ................................... 4-2]V ................................. 4-3]a ............................. 4-412 ................................... 4-5WCAP- 17252-NPMay 2012Revision 2 viiACRONYMS3-D[CLTPEPUFEMMSLPSDRMSSNRSRVthree-dimensional]ccurrent licensed thermal powerextended power upratefinite element modelmain steam linepower spectral densityroot mean squaresignal-to-noise ratiosafety relief valveWCAP-17252-NPMay 2012Revision 2 1-11 EXECUTIVE SUMMARY]aIjaI]I"c In conclusion, based on a detailed pressure load definition obtained using []a it was determined that []a~bcI]aWCAP- 17252-NPMay 2012Revision 2 2-12 12.1 INTRODUCTIONII aSab, cWCAP- I 7252-NP May 2012WCAP- 17252-NPMay 2012Revision 2 2-22.2I aII abFigure 2-1 [II aWCAP- 17252-NPMay 2012Revision 2 2-372-3Figure 2-2 [ibIIa.,bWCAP- 17252-NPMay 2012Revision 2 2-4_bFigure 2-3 [Figure 2-4 [IbWCAP- 17252-NPMay 2012Revision 2 2-52.3[ l[iaa[] aaFigure 2-5WCAP- 17252-NP May 2012Revision 2 2-6] ala[ ]LI I'a[aWCAP- 17252-NP May 2012Revision 2 2-7]aa[K a]aaWCAP-1725 2-NP May 2012Revision 2 2-8ja]aa[WCAP-17252-NP May 2012Revision 2 2-9a, bFigure 2-6 [a, bII[]a, bI a, cWCAP- 17252-NPMay 2012Revision 2 3-13I a3.1 INTRODUCTIONIIIa* II* 1IaII aFigure 3-1 1inIWCAP-17252-NPMay 2012Revision 2 3-2]a3.2 [ Table 3-1 ] b,a, b, c3.3 [a[WCAP-17252-NP May 2012Revision 2 3-3Table 3-2 ]i, b, ca, b, cTable 3-3 [ la, b, cTable 3-4 ca,b,c abca, b, cWCAP-17252-NPMay 2012Revision 2 4-14]aTable 4-1 a, ,bc -a,bcWCAP-17252-NP May 2012Revision 2 4-2a, cFigure 4-1 1JWCAP-17252-NPMay 2012Revision 2 4-3a, cFigure 4-2 1aWCAP- 17252-NPMay 2012Revision 2 4-4Fa, cFigure 4-3]aWCAP-17252-NPMay 2012Revision 2 4-5a, cFigure 4-4 []aWCAP-17252-NPMay 2012Revision 2 5-15 REFERENCES1. 1]a, b, c2. [la, b, c3.ab,cWCAP- 17252-NP May 2012Revision 2