Enclosure 25 AREVA Report ANP-3139(NP)
Nuclear Fuel Design Report Monticello Cycle 28 ATRIUM 1OXM Fuel Revision 1 203 pages follow
~Uontrolleci Uocument ANP-3139(NP)
Revision 1 Nuclear Fuel Design Report Monticello Cycle 28 ATRIUM TM 1OXM Fuel May 2013 A
AREVA NP Inc. AREVA
Uontroiied uocument AREVA NP Inc.
ANP-3139(NP)
Revision 1 Nuclear Fuel Design Report Monticello Cycle 28 ATRIUM TM 1OXM Fuel sja
Lontrolled Document AREVA NP Inc.
ANP-3139(NP)
Revision 1 Copyright @ 2013 AREVA NP Inc.
All Rights Reserved
u.ontrolle:: uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page i Nature of Changes Item .Page Description and Justification
- 1. Throughout Placed proprietary brackets ( []) throughout the document.
AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page ii Contents 1 .0 Intro d u c tio n .................................................................................................................. 1-1 2 .0 Ne utro n ic D e s ig n .......................................................................................................... 2-1 2.1 Neutronic Design Description ....................................................................... 2-1 2.2 Lattice Control Blade Worths and Kinetics Parameters ..................................... 2-2 2.3 Enriched Lattice Uncontrolled Reactivities and Isotopic Data ............................ 2-2 2 .4 C riticality C om pliance ....................................................................................... 2-2 3 .0 R efe re n c e s ................................................................................................................... 3 -1 Appendix A Enriched Lattice Hot Uncontrolled Reactivity and LPF Plots ...................... A-1 Appendix B Enriched Lattice Hot Uncontrolled Reactivity and LPF Tables .................. B-1 Appendix C Enriched Lattice Isotopic Data Tables ...................................................... C-1 Appendix D Lattice Enrichment Distribution Maps ........................................................ D-1 Tables 2.1 Neutronic Design Parameters ....................................................................................... 2-3 2.2 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment .............................................................................. 2-8 2.3 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ............................................................... 2-9 2.4 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .......................................................... 2-10 2.5 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .......................................................... 2-11 2.6 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ................................................................... 2-12 2.7 Lattice [ ] Kinetics Parameters at BOL ........................................ 2-12 2.8 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ....................................................................... 2-13 2.9 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ............................................................. 2-14 2.10 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) ............................................................... 2-15 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page iii 2.11 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) ................................................................ 2-16 2.12 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ................................................................... 2-17 2.13 Lattice [ ] Kinetics Parameters at BOL ........................................ 2-17 2.14 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-18 2.15 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-19 2.16 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-20 2.17 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-21 2.18 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-22 2.19 Lattice [ ] Kinetics Parameters at BOL .................................. 2-22 2.20 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-23 2.21 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-24 2.22 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-25 2.23 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-26 2.24 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-27 2.25 Lattice [ ] Kinetics Parameters at BOL .................................. 2-27 2.26 Lattice ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-28 2.27 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-29 2.28 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-30 2.29 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-31 2.30 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-32 2.31 Lattice [ ] Kinetics Parameters at BOL .................................. 2-32 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page iv 2.32 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-33 2.33 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-34 2.34 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-35 2.35 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-36 2.36 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-37 2.37 Lattice [ ] Kinetics Parameters at BOL .................................. 2-37 2.38 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE Original Equipment ............................................................................ 2-38 2.39 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ............................................................. 2-39 2.40 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) ............................................................... 2-40 2.41 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) ................................................................ 2-41 2.42 Lattice f ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ................................................................... 2-42 2.43 Lattice [ ] Kinetics Parameters at BOL ........................................ 2-42 2.44 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-43 2.45 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-44 2.46 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-45 2.47 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-46 2.48 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-47 2.49 Lattice [ ] Kinetics Parameters at BOL .................................. 2-47 2.50 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-48 2.51 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-49 2.52 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-50 AREVA NP Inc.
u;ontrollea uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page v 2.53 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-51 2.54 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-52 2.55 Lattice [ Kinetics Parameters at BOL .................................. 2-52 2.56 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-53 2.57 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-54 2.58 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-55 2.59 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-56 2.60 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-57 2.61 Lattice [ ] Kinetics Parameters at BOL .................................. 2-57 2.62 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-58 2.63 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-59 2.64 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-60 2.65 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-61 2.66 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-62 2.67 Lattice [ ] Kinetics Parameters at BOL .................................. 2-62 2.68 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-63 2.69 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-64 2.70 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-65 2.71 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-66 2.72 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-67 2.73 Lattice [ ] Kinetics Parameters at BOL .................................. 2-67 AREVA NP Inc.
Uontrollea Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page vi 2.74 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-68 2.75 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-69 2.76 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) ............................ 2-70 2.77 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-71 2.78 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-72 2.79 Lattice [ ] Kinetics Parameters at BOL .................................. 2-72 2.80 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-73 2.81 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-74 2.82 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-75 2.83 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-76 2.84 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-77 2.85 Lattice [ ] Kinetics Parameters at BOL .................................. 2-77 2.86 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment ................................................................ 2-78 2.87 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section) ................................................. 2-79 2.88 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) .................................................. 2-80 2.89 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section) .................................................... 2-81 2.90 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section) ....................................................... 2-82 2.91 Lattice [ ] Kinetics Parameters at BOL .................... 2-82 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page vii Figures 2.1 Assembly Type [ ]................................................................... 2-83 2.2 Assembly Type [ ]................................................................... 2-84 2.3 Assembly Type [ ]................................................................... 2-85 2.4 [ ] Fuel Rod Distribution .......................................................... 2-86 2.5 [ Fuel Rod Distribution .......................................................... 2-87 2.6 [ ] Fuel Rod Distribution .......................................................... 2-88 2.7 Fuel Rod Axial Descriptions ........................................................................................ 2-89 AREVA NP Inc.
uontroIled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page viii Nomenclature BOL beginning of life BWR boiling water reactor EVC plenum region in a fuel pin modeled as an evacuated section GWd/MTU gigawatt days per metric ton of initial uranium kg/MTU kilograms per metric ton of initial uranium LHGR linear heat generation rate LPF local peaking factor MCPR minimum critical power ratio MWd/MTU megawatt days per metric ton of initial uranium NRC Nuclear Regulatory Commission, U.S.
AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 1-1 1.0 Introduction This report provides results of the neutronic design analyses performed by AREVA NP Inc.
(AREVA) for the Monticello Cycle 28 transition ATRIUM TM* 1OXM boiling water reactor (BWR) fuel assemblies scheduled to be loaded in Cycle 28. The mechanical and thermal-hydraulic analysis results for the fuel are summarized in References 1 and 8.
Applicable neutronic design criteria are provided in the approved topical report ANF-89-98(P)(A)
Revision 1 and Supplement 1 (Reference 2). Neutronic design analysis methodology used to determine conformance to design criteria has been reviewed and approved by the NRC in the topical report EMF-2158(P)(A) (Reference 3).
The fuel design includes AREVA NP advanced fuel channels. Mechanical design criteria applicable to the design of these channels have been reviewed and approved by the NRC.
Reference 1 provides details of the application of the advanced channel for Monticello.
The neutronic design for the fabrication batch includes axially-varying enrichment and gadolinia designs with natural U0 2 blankets at the top and bottom of the assembly. The fabrication batch consists of [ 1] [ ], and [
] assemblies (Reference 5). Pertinent fuel and reactor core design information associated with this fabrication batch is given in Section 2.0 and in Appendices A through D.
- ATRIUM is a trademark of AREVA NP.
AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-1 2.0 Neutronic Design The results of the Monticello Cycle 28 transition ATRIUM 1OXM neutronic design analyses are presented in this section. The fuel was designed to meet applicable design criteria, as well as reactivity and control requirements. Reactor core loading patterns and the number of assemblies to be loaded will depend upon final cycle energy requirements as specified by the utility. Applicable neutronic design criteria outlined in Reference 2 are summarized below:
Power Distribution. The local power distribution in the fuel assembly combined with the core power distribution shall result in Linear Heat Generation Rate (LHGR) and Minimum Critical Power Ratio (MCPR) values that are within the limits established for each fuel design.
Kinetics Parameters. The moderator void reactivity coefficient due to boiling in the active channels and the Doppler fuel temperature reactivity coefficient shall be negative.
The negative void and Doppler reactivity coefficients ensure a negative power coefficient during reactor operation. Additional calculations were performed to show that the assembly average Doppler and void reactivity coefficients remain negative for the life of the assembly. These results demonstrate that the Reference 2 kinetics criteria are met on a bundle average basis.
Control Blade Reactivity. The design of the fuel assembly and the reactor core loading shall be such that the technical specification shutdown margin requirement is met for all reactor conditions.
2.1 Neutronic Design Description The neutronic design parameters are presented in Table 2.1. The key XM reload assembly nuclear design characteristics are summarized below:
- The fuel assembly contains [
]. The water channel also serves the function of the spacer capture rod.
- Each fuel assembly has top and bottom natural uranium blankets.
0 The enrichments are designed to yield a local power distribution which results in a balanced design relative to MCPR, LHGR, and other reactor operating requirements, e.g., power peaking.
0 Gadolinia (Gd 2 0 3 blended with U0 2 ) rods are designed to control assembly reactivity in order to meet reactivity control requirements in the reactor, e.g. cold shutdown margin.
- The reload batch consists of 3 assembly designs which vary axially in enrichment and/or gadolinia. The axial distributions of the lattices in the assemblies are shown in Figures 2.1, 2.2, and 2.3. The fuel rod distribution and axial descriptions are presented in Figures 2.4 through 2.7. The enrichment and gadolinia distribution maps for each of the reload assembly lattices are displayed in Appendix D.
AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-2 The fuel assembly incorporates the AREVA NP advanced fuel channel which improves uranium utilization. For D-lattice plants, the fuel assembly is offset [ ] mils toward the control blade.
2.2 Lattice Control Blade Worths and Kinetics Parameters Beginning of life (BOL) lattice reactivities (k,) have been calculated for moderator and fuel conditions ranging from cold to hot operating conditions. From these reactivities, BOL control blade worths and kinetics parameters have been determined based on GE Original Equipment, GE Duralife 140a, and GE Marathon control blades. Kinetics parameters are calculated for fuel temperature (Doppler), moderator void, and moderator temperature. The Doppler reactivity was calculated over a fuel temperature range from hot standby to hot operating. The moderator void reactivity was evaluated between the 0% and 40% voided hot operating cases, and the moderator temperature reactivity was calculated from the cold to hot standby condition. The calculations neglect the spacer material and assume zero void in the coolant outside the fuel assembly channel as well as inside the internal water channel. The results of these calculations are presented in Tables 2.2 through 2.91.
2.3 Enriched Lattice UncontrolledReactivities and Isotopic Data The enriched lattice exposure-dependent uncontrolled reactivities calculated at three void fractions are presented graphically in Appendix A, and in tabular format in Appendix B. The enriched lattice exposure-dependent isotopic data calculated at three void fractions are presented in Appendix C.
2.4 CriticalityCompliance The Monticello Cycle 28 transition ATRIUM 1OXM fuel assemblies satisfy the fuel design critical safety limits established for new and spent fuel storage at the Monticello facility per Reference
- 4. Additionally, these reload assemblies conform to the nuclear criticality requirements as provided to the NRC for the References 6 and 7 shipping container.
AREVA NP Inc.
uontrolied uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-3 Table 2.1 Neutronic Design Parameters
[
I
- [ I t [
I AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-4 Table 2.1 Neutronic Design Parameters (Continued)
I I
AREVA NP Inc.
T ontroniesi 2 Pocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-5 Table 2.1 Neutronic Design Parameters (Continued)
[
I
[
t [ I AREVA NP Inc.
Uontrollea Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-6 Table 2.1 Neutronic Design Parameters (Continued)
[
I AREVA NP Inc.
Controlled Documerit Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-7 Table 2.1 Neutronic Design Parameters (Continued)
]
Core Data*
Number of fuel assemblies in the core 484 Rated thermal power level, MWt 2004.0 Rated core flow, Mlbm/hr 57.60 Inlet subcooling, Btu/Ibm 23.37 Dome pressure, psia 1025.0 Boron concentration, PPM 660.0 Intermediate temperature, OF 200.00 Warm temperature, OF 360.00
- Some values are representative of rated conditions and may vary depending on the core statepoint.
AREVA NP Inc.
ControEiled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-8 Table 2.2 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator=68 0 F TFuel=68 0 F 0.65725 0.81345 -0.1920 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFueI=200 0 F 0.64913 0.82100 -0.2093 0% Void, No xenon 0
Hot Standby TModerator=55 F TFue=55 0 ° F 0.61871 0.85838 -0.2792 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=995 0 F 0.61514 0.85399 -0.2797 0% Void, No xenon Hot Operatingo TModerator=550 F TFuej=995 0 F 0.61519 0.85399 -0.2796 0% Void Hot Operating 4o TModerator=550° F TFueI=995 0 F 0.58852 0.87738 -0.3292 40% Void Hot Operating 80 TModerator=550° F TFueI=995° F 0.53537 0.89408 -0.4012 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-9 Table 2.3 Lattice[ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontrolled - kUnc.ntrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 80 Cold TModerator=6 F TFueI=68 0 F 0.65915 0.81345 -0.1897 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel=200 0 F 0.65141 0.82100 -0.2066 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550 0 F 0.62209 0.85838 -0.2753 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFueI=995 0 F 0.61852 0.85399 -0.2757 0% Void, No xenon Hot Operatingo TModerator=550° F TFel=995° F 0.61856 0.85399 -0.2757 0% Void Hot Operating 4o TModerator=550° F TFue=995 0 F 0.59231 0.87738 -0.3249 40% Void Hot Operating 80 TModerator=550 F TFue=995 0 F 0.53963 0.89408 -0.3964 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-10 Table 2.4 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kuncntrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator=68 0 F TFuel=68 0 F 0.65565 0.81345 -0.1940 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200 0 F 0.64784 0.82100 -0.2109 0% Void, No xenon Hot Standby TModerator-550° F TFuel=550 0 F 0.61740 0.85838 -0.2807 0% Void, No xenon Hot OperatingNoxe TModerator-550° F TFuel=995 0 F 0.61389 0.85399 -0.2812 0% Void, No xenon Hot Operatingo TModerator-550° F TFueI=995 0 F 0.61389 0.85399 -0.2812 0% Void Hot Operating 4o TModerator"550° F TFueI=995 0 F 0.58585 0.87738 -0.3323 40% Void Hot Operating 80 TModerator"550 F TFuel= 9 95 0 F 0.53057 0.89408 -0.4066 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-11 Table 2.5 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = 'kcontrolled - kUncontrolled Worth kUncontro~led kcontrolled kUncontrolled (Ak/k) 6 8 0 Cold TModerator= F TFuel=68 0 F 0.65467 0.81345 -0.1952 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFuel=200 0 F 0.64677 0.82100 -0.2122 0% Void, No xenon Hot Standby TModerator= 5 5 0 0 F TFueI=550 0 F 0.61639 0.85838 -0.2819 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFueI=995 0 F 0.61285 0.85399 -0.2824 0% Void, No xenon Hot Operatingo TModerator=5500 F TFuel=995 0 F 0.61289 0.85399 -0.2823 0% Void Hot Operating 40 TModerator=55 0
° F TFuel=995 0 F 0.58507 0.87738 -0.3332 40% Void Hot Operating 80 TModerator=550° F TFuel=995 0 F 0.53047 0.89408 -0.4067 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-12 Table 2.6 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = Ikcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.65239 0.81345 -0.1980 0% Void, No xenon TModerator= 2 0 00 Intermediate F TFuel=200 0 F 0.64445 0.82100 -0.2150 0% Void, No xenon Hot Standby TMederator=550 F TFuel=55 0 ° F 0.61338 0.85838 -0.2854 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuei=995 0 F 0.60988 0.85399 -0.2858 0% Void, No xenon 0
Hot Operatingo TModerator=550° F TFuel=995 F 0.60991 0.85399 -0.2858 0% Void Hot Operating 40 TModerator=550° F TFuel=995 0 F 0.58107 0.87738 -0.3377 40% Void Hot Operating 80 TModerator=55 0
° F TFuei=995 0 F 0.52501 0.89408 -0.4128 80% Void Table 2.7 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = k.a- 13 Parameter ko k. ko (Ak/k)
Doppler kHotOperatingNoXe - 'kHotStandby 0.85399 0.85838 -0.0051 kHotStandby 0.87738 0.85399 0.0274 Moderatorv~id kHotOperafing - kHotOperaungO (kHotOperatingo kHotStandby kCold 0.85838 0.81345 0.0552 Moderatorremperture - -
kc-old AREVA NP Inc.
Controlled Documnent Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM IOXM Fuel Page 2-13 Table 2.8 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kControlled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
TModerator= 6 80 Cold F TFuel= 6 8 0 F 0.68755 0.84096 -0.1824 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFuel= 2 0 00 F 0.67889 0.84687 -0.1983 0% Void, No xenon Hot Standby TModerator=
5 5 0
° F TFuel=550 0 F 0.64491 0.87554 -0.2634 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel= 93 50 F 0.64145 0.87134 -0.2638 0% Void, No xenon 93 0 Hot Operating 0 TModerator=550 F TFueI= 5 F 0.64150 0.87134 -0.2638 0% Void Hot Operating 4o TModerator=550° F TFue=9350 F 0.61180 0.88779 -0.3109 40% Void Hot Operating 80 TModerator=550° F TFu1=935 0 F 0.55633 0.89608 -0.3791 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-14 Table 2.9 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kControlled - kuncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.68936 0.84096 -0.1803 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFuel=200 0 F 0.68104 0.84687 -0.1958 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.64805 0.87554 -0.2598 0% Void, No xenon Hot OperatingNoxe TMiderator=55 0 0 F TFueI=935 0 F 0.64459 0.87134 -0.2602 0% Void, No xenon Hot Operatingo TModerator=5500 F TFuel=935 0 F 0.64463 0.87134 -0.2602 0% Void Hot Operating 4o TModerator=550 0 F TFue,=935 0 F 0.61529 0.88779 -0.3069 40% Void Hot Operating 80 Tmoderator=550 F TFuel=935 0 F 0.56025 0.89608 -0.3748 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-15 Table 2.10 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = - kuncontrolled Worth kuncontro,,ed kcontrolled kUncontrolled (Ak/k) 0 Cold TModerator= 6 8 F TFuel=68 0 F 0.68585 0.84096 -0.1844 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFueI=200 0 F 0.67743 0.84687 -0.2001 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550 0 F 0.64325 0.87554 -0.2653 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel=935 0 F 0.63985 0.87134 -0.2657 0% Void, No xenon Hot Operating 0 TModerator=5500 F TFuel= 9 35 0 F 0.63985 0.87134 -0.2657 0% Void Hot Operating 4o TModerator=550° F TFue1=935 0 F 0.60872 0.88779 -0.3143 40% Void 0
Hot Operating 80 TModerator=550 F TFueI935 0 F 0.55117 0.89608 -0.3849 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-16 Table 2.11 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 680 F TFuel= 6 8 0 F 0.68503 0.84096 -0.1854 0% Void, No xenon Intermediate Tmoderater=
2 0 0 0 F TFuel=200 0 F 0.67658 0.84687 -0.2011 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.64250 0.87554 -0.2662 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TFuel=935 0 F 0.63908 0.87134 -0.2666 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=935° F 0.63911 0.87134 -0.2665 0% Void Hot Operating 40 TFuel=935 0 0
TModerator=55 ° F F 0.60825 0.88779 -0.3149 40% Void 9 0 Hot Operating 80 TModerator=55 0
F TFUeI= 35 F 0.55136 0.89608 -0.3847 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-17 Table 2.12 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantrolled - kUncontroI1ed Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerato= 6 80 F TFuel=68 0 F 0.68273 0.84096 -0.1882 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFuel=200 0 F 0.67423 0.84687 -0.2039 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.63946 0.87554 -0.2696 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuej=935 0 F 0.63606 0.87134 -0.2700 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel=935 0 F 0.63609 0.87134 -0.2700 0% Void Hot Operating 40 TModerator=550° F TFuel=935 0 F 0.60422 0.88779 -0.3194 40% Void Hot Operating 80 TModerator=55 0
° F TFueI=935 0 F 0.54590 0.89608 -0.3908 80% Void Table 2.13 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter -kk k Parameter ko k,. k5 (Ak/k)
Doppler kHotOperatingNoXe - kHotStandby 0.87134 0.87554 -0.0048 DkHotStandby Moderatorvcd =kHotOperating40 - kHotOperatingO 0.88779 0.87134 0.0189 kHotOperatingo kHotStandby - kc0ld 0.87554 0.84096 0.0411 ModeratorTemprture = kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-18 Table 2.14 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kContmlled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel= 6 8 0 F 0.93110 1.10798 -0.1596 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel= 2 00 0 F 0.91649 1.10000 -0.1668 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550° F 0.86015 1.06920 -0.1955 0% Void, No xenon Hot OperatingNaxe TModerator=550° F TFueI=935a F 0.85630 1.06448 -0.1956 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=9 350 F 0.85637 1.06448 -0.1955 0% Void Hot Operating 40 TModerator=5500 F TFueI=935 0 F 0.81640 1.04583 -0.2194 40% Void Hot Operating 80 TModerator=550° F TFuel=935 0 F 0.76827 1.02214 -0.2484 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTm 1OXM Fuel Page 2-19 Table 2.15 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth Wo=
kuncontrolled kControlled kUncontrolled (Ak/k)
Cold TModerator=68 0
F TFuel=68 0 F 0.93246 1.10798 -0.1584 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.91797 1.10000 -0.1655 0% Void, No xenon Hot Standby TModerator= 5 5 0
° F TFuel=550 0 F 0.86168 1.06920 -0.1941 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0 0 F TFuel=9350 F 0.85784 1.06448 -0.1941 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=935 0 F 0.85791 1.06448 -0.1941 0% Void Hot Operating 4o TFueI=935 0 5 5 0 TModerator= ° F F 0.81766 1.04583 -0.2182 40% Void TFuel=935 0 0
Hot Operating 80 TModerator=55 0 F F 0.76895 1.02214 -0.2477 80% Void AREVA NP Inc.
Controlled Docume~nt Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-20 Table 2.16 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontralled - kuncontraled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.92717 1.10798 -0.1632 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFuel=200 0 F 0.91237 1.10000 -0.1706 0% Void, No xenon Hot Standby TModerator=550 F TFue=550 0 F 0.85373 1.06920 -0.2015 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=935 F 0
0.84994 1.06448 -0.2015 0% Void, No xenon Hot Operatingo TModeratro=550 F TFuel=935 0 F 0.84994 1.06448 -0.2015 0% Void Hot Operating 4O TModerator=550° F TFueI=935 0 F 0.80762 1.04583 -0.2278 40% Void Hot Operating 8 0 TModerator=550° F TFue=935 0 F 0.75618 1.02214 -0.2602 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-21 Table 2.17 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcontrolled - kuncontrolled Worth kuncontrolled kContold kUncontrotled (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.92704 1.10798 -0.1633 0% Void, No xenon 2 000 Intermediate TModerator= F TFueI=2 00 0 F 0.91248 1.10000 -0.1705 0% Void, No xenon Hot Standby TModerator=55 0
° F TFueI-550 0 F 0.85500 1.06920 -0.2003 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFueI=9 350 F 0.85119 1.06448 -0.2004 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=935 0 F 0.85125 1.06448 -0.2003 0% Void Hot Operating 4o TModerator=550° F TFueI=935 0 F 0.80992 1.04583 -0.2256 40% Void Hot Operating 80 TModerator=550° F TFuel=935 0 F 0.76032 1.02214 -0.2561 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-22 Table 2.18 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
TModerator= 6 8 0 80 6
Cold F TFuel= F 0.92339 1.10798 -0.1666 0% Void, No xenon 0 00 Intermediate TModerator=2 F TFuel= 2 0 00 F 0.90874 1.10000 -0.1739 0% Void, No xenon Hot Standby TModerator=550 F TFueI=550- F 0.85027 1.06920 -0.2048 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TF,,eI=9 35° F 0.84649 1.06448 -0.2048 0% Void, No xenon Hot Operatingo TFuel=935 0 0
TModerator=55 ° F F 0.84655 1.06448 -0.2047 0% Void Hot Operating 40 TModerator=550 F TFuel= 9 35 0 F 0.80396 1.04583 -0.2313 40% Void 50 93 Hot Operating 80 TModerator=550° F TFuel= F 0.75243 1.02214 -0.2639 80% Void Table 2.19 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter k.
-Parameter ko k. ko (Ak/k)
Doppler =kHotOperatingNoXe - kHotStandby 1.06448 1.06920 -0.0044 DkHotStandby Moderatorvoid =kHotOperaUng40 - kHotOperatingO 1.04583 1.06448 -0.0175 kHotOperatingO kHotStandby - kCold 1.06920 1.10798 -0.0350 ModeratorTemperature - kcold AREVA NP Inc.
Controlled Docurment Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-23 Table 2.20 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kControlled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k) 6 80 0 Cold TModerator= F TFuel=68 F 0.91138 1.08334 -0.1587 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFueI=200 0 F 0.89666 1.07471 -0.1657 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.84181 1.04381 -0.1935 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFueI=935 0 F 0.83809 1.03924 -0.1935 0% Void, No xenon Hot Operatingo TModerator--550 F TFueI=935 0 F 0.83816 1.03924 -0.1935 0% Void Hot Operating 40 TModerator=550 F TFuei=935 0 F 0.80136 1.02258 -0.2163 40% Void 0
Hot Operating 80 TModerator=550° F TFuel=935 F 0.75734 1.00098 -0.2434 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTm 10XM Fuel Page 2-24 Table 2.21 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kCntrolled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.91286 1.08334 -0.1574 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.89826 1.07471 -0.1642 0% Void, No xenon Hot Standby TModerator=
5 5 0
° F TFueI=550 0 F 0.84343 1.04381 -0.1920 0% Void, No xenon Hot OperatingNoxe TModerator= 5 5 0
° F TFuel=935 0 F 0.83972 1.03924 -0.1920 0% Void, No xenon Hot Operating 0 TModerator=5500 F TFuel= 9 35 0 F 0.83978 1.03924 -0.1919 0% Void Hot Operating 40 TModeratoO=550 F TFuel= 9 3 50 F 0.80265 1.02258 -0.2151 40% Void Hot Operating 80 TModerator"5500 F TFueI=935 0 F 0.75796 1.00098 -0.2428 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-25 Table 2.22 Lattice[ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcantrolled - kUncontrolled Worth kunconr*t ld kcontrolled kUncontrolled (Ak/k)
Cold TMderator=6 80 F TFuel= 6 8 0 F 0.90788 1.08334 -0.1620 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFuel=200 0 F 0.89298 1.07471 -0.1691 0% Void, No xenon Hot Standby TModerator=550 F TFueI=550 0 F 0.83593 1.04381 -0.1992 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=935 0 F 0.83227 1.03924 -0.1992 0% Void, No xenon Hot Operating 0 0 TModerator=55 ° F TFueI=935° F 0.83227 1.03924 -0.1992 0% Void Hot Operating 40 TModerator=550 F TFuel=935 0 F 0.79312 1.02258 -0.2244 40% Void Hot Operating 80 TModerator=5500 F TFuej=935 0 F 0.74572 1.00098 -0.2550 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-26 Table 2.23 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcantrolled - kUncontmlled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold Taoderalto= F TFueI=68 0 F 0.90768 1.08334 -0.1621 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.89300 1.07471 -0.1691 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.83709 1.04381 -0.1980 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=935 0 F 0.83341 1.03924 -0.1981 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel=935 0 F 0.83346 1.03924 -0.1980 0% Void Hot Operating 40 TModerator=550° F TFuel=935 0 F 0.79533 1.02258 -0.2222 40% Void Hot Operating 80 TModerator=550° F TFueI=935 0 F 0.74978 1.00098 -0.2510 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-27 Table 2.24 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantralled - kuncontmlled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.90426 1.08334 -0.1653 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200° F 0.88949 1.07471 -0.1723 0% Void, No xenon Hot Standby TModertor=5500 F TFueI=550 0 F 0.83261 1.04381 -0.2023 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFueI=935 0 F 0.82897 1.03924 -0.2023 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel=935 0 F 0.82902 1.03924 -0.2023 0% Void Hot Operating 4 o TModerator=5500 F TFuel=935 0 F 0.78961 1.02258 -0.2278 40% Void Hot Operating 80 TModerator=5500 F TFue,=935 0 F 0.74212 1.00098 -0.2586 80% Void Table 2.25 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter Kk k Parameter ko k. ko (Ak/k)
Doppler kHotOperatingNoXe - kHotStandby 1.03924 1.04381 -0.0044 kHotStandby Moderatorvlid kHotOperajngQo - kHotOperafingo 1.02258 1.03924 -0.0160 okHotOperatingO kHotStandby - kCold 1.04381 1.08334 -0.0365 ModeratorTemerlure = k(cold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-28 Table 2.26 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kcontrolled - kuncontrolled Worth kunmontroied kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=6 8 0 F 0.87398 1.04891 -0.1668 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.86131 1.04340 -0.1745 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550° F 0.81510 1.02386 -0.2039 0% Void, No xenon 9 9 Hot OperatingNoXe TModerator=550 F TFue1= 50 F 0.81142 1.01928 -0.2039 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel= 9 9 50 F 0.81148 1.01928 -0.2039 0% Void Hot Operating 40 TModerator=550° F TFueI=9 950 F 0.77722 1.00778 -0.2288 40% Void Hot Operating 80 TModerator=5500 F TFuel=995° F 0.73165 0.98971 -0.2607 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-29 Table 2.27 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kControlled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 0 Cold TModerator=68 F TFuel=68 0 F 0.87562 1.04891 -0.1652 0% Void, No xenon 2 000 Intermediate TModerator= F TFueI=2 00 0 F 0.86310 1.04340 -0.1728 0% Void, No xenon Hot Standby TModerator= 5 5 0
° F TFuel=550 0 F 0.81703 1.02386 -0.2020 0% Void, No xenon Hot OperatingNoxe TModerator'550 F TFuel=995° F 0.81336 1.01928 -0.2020 0% Void, No xenon Hot Operatingo TModerator=5500 F TFuej=995 0 F 0.81341 1.01928 -0.2020 0% Void Hot Operating 4o TModerator=550° F TFueI=995 0 F 0.77889 1.00778 -0.2271 40% Void 50 99 Hot Operating 80 TModerator=550° F TFuel= F 0.73272 0.98971 -0.2597 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-30 Table 2.28 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
Cold TModerator=68 0 F TFue==6 80 F 0.87059 1.04891 -0.1700 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.85782 1.04340 -0.1779 0% Void, No xenon Hot Standby TModerator= 5 50° F TFue=550 0 F 0.80965 1.02386 -0.2092 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=995° F 0.80603 1.01928 -0.2092 0% Void, No xenon 0
Hot Operating 0 TModerator=550 F TFuel= 9 9 5 0
F 0.80603 1.01928 -0.2092 0% Void Hot Operating 40 TModerator= 5 50
° F TFueI=9 9 5 0 F 0.76940 1.00778 -0.2365 40% Void Hot Operating 80 TModerator=5500 F TFueI=9 9 5 0
F 0.72024 0.98971 -0.2723 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-31 Table 2.29 Lattice[ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 6 80 Cold TModerator= F TFuel= F 0.86990 1.04891 -0.1707 0% Void, No xenon Intermediate TModerator 2 000 F TFuel=200 0 F 0.85733 1.04340 -0.1783 0% Void, No xenon Hot Standby TModerator=55 0
° F TFuel=5500 F 0.81028 1.02386 -0.2086 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TF,et=995 0 F 0.80663 1.01928 -0.2086 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=995 0 F 0.80669 1.01928 -0.2086 0% Void 0
Hot Operating 40 TModerator=55 ° F TFueI=995° F 0.77103 1.00778 -0.2349 40% Void Hot Operating 80 TModerator=550° F TFuel=995 0 F 0.72384 0.98971 -0.2686 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-32 Table 2.30 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel=68 0 F 0.86652 1.04891 -0.1739 0% Void, No xenon Intermediate TModertor= 2 000 F TFueI=200 0 F 0.85387 1.04340 -0.1817 0% Void, No xenon Hot Standby TModerator=
5 5 0
° F TFueI=550 0 F 0.80590 1.02386 -0.2129 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFuel=995 0 F 0.80229 1.01928 -0.2129 0% Void, No xenon Hot Operatingo TFuel=995 0 5 5 0 TModerator= 0 F F 0.80235 1.01928 -0.2128 0% Void 5 5 Hot Operating 40 TModerator= O0 F TFueI=995° F 0.76542 1.00778 -0.2405 40% Void Hot Operating 80 TModerator=550° F TFel= 9 95 0 F 0.71619 0.98971 -0.2764 80% Void Table 2.31 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter - ko Parameter ko k. ko (Ak/k)
Doppler - kHotOperatingNoXe - kHotStandby 1.01928 1.02386 -0.0045 kHotStandby Moderatorvoid = kHotOperating40- kHotOperatingO 1.00778 1.01928 -0.0113 kHotOperatingO Moderator-remture - kHotStandby - kCold 1.02386 1.04891 -0.0239 kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Repo -t ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMT'M 10XM Fuel Page 2-33 Table 2.32 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kcontroaled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
Cold FT 0 F
=ue=68 TModeratorS68 0.91470 1.08373 -0.1560 0% Void, No xenon 0 00 Intermediate TModerator= 2 F TFuel=200 0 F 0.90308 1.07951 -0.1634 0% Void, No xenon Hot Standby TModerator=55 0
° F TFueI=550 0 F 0.85903 1.06545 -0.1937 0% Void, No xenon Hot OperatingNoxe TModerator-550 F TFueI=995 0 F 0.85523 1.06077 -0.1938 0% Void, No xenon Hot Operating 0 TModerator'550 F TFueI=9 9 5 0 F 0.85530 1.06077 -0.1937 0% Void Hot Operating 40 TModerator"550° F TFuel=995 0 F 0.81960 1.05090 -0.2201 40% Void Hot Operating 80 TModerator"550° F TFueI=995 0 F 0.77080 1.03402 -0.2546 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-34 Table 2.33 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth kUncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModeratr= 6 80 F TFuel=68 0 F 0.91621 1.08373 -0.1546 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFuel=200 0 F 0.90473 1.07951 -0.1619 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.86084 1.06545 -0.1920 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFueI=995 0 F 0.85704 1.06077 -0.1921 0% Void, No xenon Hot Operating0 TModerator=5500 F TFue=995 0 F 0.85710 1.06077 -0.1920 0% Void Hot Operating 4o TModerator--550 F TFuel=995 0 F 0.82108 1.05090 -0.2187 40% Void Hot Operating 80 TModerator=5500 F TFueI=995 0 F 0.77162 1.03402 -0.2538 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-35 Table 2.34 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kuncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
Cold TModertor=68 0 F TFuel= 6 80 F 0.91147 1.08373 -0.1590 0% Void, No xenon 2 0 0 0 Intermediate TModerator= F TFuel=200° F 0.89983 1.07951 -0.1664 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.85360 1.06545 -0.1988 0% Void, No xenon Hot OperatingNoxe TModerator=550- F TFuel=995° F 0.84985 1.06077 -0.1988 0% Void, No xenon Hot Operating 0 TModerator'-550° F TFuel=995 0 F 0.84985 1.06077 -0.1988 0% Void Hot Operating 40 TModerator-550 F TFueI=995 0 F 0.81153 1.05090 -0.2278 40% Void Hot Operating 80 TModerator=5500 F TFueI=995° F 0.75872 1.03402 -0.2662 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-36 Table 2.35 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kContmlled - kuncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 0 Cold TModerator=68 F TFuel=68 0 F 0.91086 1.08373 -0.1595 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=200° F 0.89931 1.07951 -0.1669 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.85431 1.06545 -0.1982 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel=995 0 F 0.85055 1.06077 -0.1982 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=995 0 F 0.85060 1.06077 -0.1981 0% Void 0
Hot Operating 40 TModerator=55 ° F TFueI=995° F 0.81333 1.05090 -0.2261 40% Void Hot Operating 80 Tmoderator=550° F TFu 6=995° F 0.76263 1.03402 -0.2625 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-37 Table 2.36 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k)
Cold TModerator=
6 80 F TFuel=68O F 0.90755 1.08373 -0.1626 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFueI=200° F 0.89592 1.07951 -0.1701 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550 0 F 0.84991 1.06545 -0.2023 0% Void, No xenon Hot OperatingNoxe TModerator-550 F TFueI=995 0 F 0.84619 1.06077 -0.2023 0% Void, No xenon Hot Operating 0 TModerator=5500 F TFueI=995 0 F 0.84624 1.06077 -0.2022 0% Void Hot Operating 40 TModerator=5500 F TFue1=995 0 F 0.80758 1.05090 -0.2315 40% Void Hot Operating 80 TModerator=550 F TFuel=995° F 0.75465 1.03402 -0.2702 80% Void Table 2.37 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = - Parameter ko k. ko (Ak/k)
Doppler kHotOperatjngNoXe- kHotStandby 1.06077 1.06545 -0.0044 kHotStandby ModeratorvO~d = kHotOperating40 - kHotOperatingo 1.05090 1.06077 -0.0093 kHotOperafingO Moderatorrempmture - kHotStandby - kCold 1.06545 1.08373 -0.0169 okCold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-38 Table 2.38 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kControlled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.65527 0.80192 -0.1829 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel=200 0 F 0.64834 0.81033 -0.1999 0% Void, No xenon Hot Standby TModerator=5500 F TFue=550 0 F 0.62354 0.85266 -0.2687 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFueI=995 0 F 0.62009 0.84847 -0.2692 0% Void, No xenon Hot Operatingo TModerator=5500 F TFueI=995 0 F 0.62013 0.84847 -0.2691 0% Void Hot Operating 40 TModerator=5500 F TFuel=995 0 F 0.59641 0.87674 -0.3197 40% Void Hot Operating 80 TModerator=5500 F TFuel=995 0 F 0.54242 0.89716 -0.3954 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-39 Table 2.39 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 80 Cold TModerator=6 F TFuel=68 0 F 0.65696 0.80192 -0.1808 0% Void, No xenon Intermediate TModerator= 2 000 F TFueI=200 0 F 0.65054 0.81033 -0.1972 0% Void, No xenon 5 50 Hot Standby TModerator= 0 F TFueI=550 0 F 0.62684 0.85266 -0.2648 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFue==995- F 0.62340 0.84847 -0.2653 0% Void, No xenon 0
Hot Operatingo TModerator=550 F TFuel=995 0 F 0.62343 0.84847 -0.2652 0% Void Hot Operating 4o TModerator=5500 F TFuel=995 0 F 0.60016 0.87674 -0.3155 40% Void Hot Operating 80 TModerator=5500 F TFueI=995 0 F 0.54669 0.89716 -0.3906 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-40 Table 2.40 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcantrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 8 Cold TModerator= ° F TFuel=68° F 0.65376 0.80192 -0.1848 0% Void, No xenon Intermediate TModerator=2 0 00 F TFu 01=200 0 F 0.64728 0.81033 -0.2012 0% Void, No xenon Hot Standby TModerator=550 F TFueI=55 0 ° F 0.62258 0.85266 -0.2698 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel=995 0 F 0.61918 0.84847 -0.2702 0% Void, No xenon Hot Operatingo TModerator=550° F TFueI=995 0 F 0.61918 0.84847 -0.2702 0% Void Hot Operating 40 TModerator=550 F TFueI=995 0 F 0.59410 0.87674 -0.3224 40% Void Hot Operating 80 TModerator=5500 F TFuel=995 0 F 0.53784 0.89716 -0.4005 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-41 Table 2.41 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kCantrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.65274 0.80192 -0.1860 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFuel=200 0 F 0.64615 0.81033 -0.2026 0% Void, No xenon Hot Standby TModerator=
5 5 0 0 F TFuel=550 0 F 0.62142 0.85266 -0.2712 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=995 0 F 0.61800 0.84847 -0.2716 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuei=995 0 F 0.61803 0.84847 -0.2716 0% Void Hot Operating 40 TModerator=550° F TFueI=995 0 F 0.59314 0.87674 -0.3235 40% Void Hot Operating 80 TModerator=550 F TFueI=995 0 F 0.53758 0.89716 -0.4008 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-42 Table 2.42 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantroed - kuncontrolled Worth kuncontrolled kControlled kuncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel=68 0 F 0.65066 0.80192 -0.1886 0% Void, No xenon Intermediate TModerator=
2 0 0
° F TFueI=200 0 F 0.64403 0.81033 -0.2052 0% Void, No xenon Hot Standby TModerator-550 F TFuel=550 0 F 0.61864 0.85266 -0.2745 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=995 0 F 0.61525 0.84847 -0.2749 0% Void, No xenon 0 F TFueI=995 0 0
Hot Operating 0 TModerator=55 F 0.61528 0.84847 -0.2748 0% Void Hot Operating 40 TModerator=550 F TFuel=995 0 F 0.58934 0.87674 -0.3278 40% Void Hot Operating 80 TModerator=550 F TFuel=995° F 0.53221 0.89716 -0.4068 80% Void Table 2.43 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter =ka-ko Parameter kp k. ký (Ak/k)
Doppler kHotOperatingNoXe - kHotStandby 0.84847 0.85266 -0.0049 kHotStandby Moderatorv0 1 d kHotOperaUng4O - kHotOpera 0ng0 0.87674 0.84847 0.0333 kHotOperatbngo kHotStandby - kcold 0.85266 0.80192 0.0633 ModeratorTemerture = kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-43 Table 2.44 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth =kcontrolled - kUncontrolled Worth kuncontraolle kControlled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68° F 0.95490 1.12686 -0.1526 0% Void, No xenon Intermediate TModerator=2 0 00 F TFueI=200 0 F 0.94096 1.11951 -0.1595 0% Void, No xenon Hot Standby TModertor=550 0
F TFuel=5500 F 0.88441 1.08985 -0.1885 0% Void, No xenon Hot OperatingNoxe TModerator=55 0
0 F TFuel=935 0 F 0.88045 1.08504 -0.1886 0% Void, No xenon Hot Operating 0 TModerator=550 0
F TFueI=935 0 F 0.88052 1.08504 -0.1885 0% Void Hot Operating 40 TModerator=550 F TFuel=935 0
F 0.83870 1.06587 -0.2131 40% Void Hot Operating 80 TModerator=550 F TFueI=935 0 F 0.78796 1.04110 -0.2432 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM M T 1OXM Fuel Page 2-44 Table 2.45 Lattice [ ] Control Blade Worths at
. BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
Cold TModerator=
6 8
° F TFuel=68 0 F 0.95617 1.12686 -0.1515 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFuej=200 0 F 0.94234 1.11951 -0.1583 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550° F 0.88584 1.08985 -0.1872 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFueI=935 0 F 0.88189 1.08504 -0.1872 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=935 0 F 0.88196 1.08504 -0.1872 0% Void Hot Operating 40 TModerator=5500 F TFuel=935° F 0.83982 1.06587 -0.2121 40% Void Hot Operating 80 TModerator=5500 F TFuel=935 0 F 0.78846 1.04110 -0.2427 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-45 Table 2.46 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth kcontrlled - kUncantrolled Worth kUncontrolled kControlled kUncontrolled (Ak/k) 6 8 0 Cold TModerator= F TFue1=68) F 0.95113 1.12686 -0.1560 0% Void, No xenon 2 0 0 0 Intermediate TModerator= F TFuel=200 0 F 0.93701 1.11951 -0.1630 0% Void, No xenon Hot Standby TModerator=550° F TFueI=5500 F 0.87809 1.08985 -0.1943 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=935 0 F 0.87419 1.08504 -0.1943 0% Void, No xenon 93 0 Hot Operating 0 TModerator- 5 5
0 0 F TFuer= 5 F 0.87419 1.08504 -0.1943 0% Void Hot Operating 40 TModerator=550° F TFueI=935 0 F 0.82990 1.06587 -0.2214 40% Void Hot Operating 80 TModerater-550 F TFueI=935 0 F 0.77567 1.04110 -0.2550 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM IOXM Fuel Page 2-46 Table 2.47 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade o
kcontrolled - kUncontroled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 8 0 F TFuel= 6 80 F 0.95105 1.12686 -0.1560 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFuel=200 0 F 0.93713 1.11951 -0.1629 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550 0 F 0.87942 1.08985 -0.1931 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
° F TFuel=935 0 F 0.87550 1.08504 -0.1931 0% Void, No xenon Hot Operatingo TModerator=550° F TFu~e=935 0 F 0.87556 1.08504 -0.1931 0% Void Hot Operating 40 TModerator=5500 F TFueI=9 35 0 F 0.83232 1.06587 -0.2191 40% Void Hot Operating 80 TModerator=550° F TF.u*= 9 3 5
0 F 0.77999 1.04110 -0.2508 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-47 Table 2.48 Lattice [ ] Control Blade Worths at
.BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantrolled - kuncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFueI=68 0 F 0.94748 1.12686 -0.1592 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFeI=200 0 F 0.93347 1.11951 -0.1662 0% Void, No xenon Hot Standby TModerator=
5 5 0
° F TFuel=550 0 F 0.87473 1.08985 -0.1974 0% Void, No xenon Hot OperatingNoXe TModerator-=550 F TFue,=935 0 F 0.87085 1.08504 -0.1974 0% Void, No xenon Hot Operatingo TModerator=550° F TFuel=935 0 F 0.87091 1.08504 -0.1973 0% Void Hot Operating 4o TModerator=550° F TFuel=935° F 0.82634 1.06587 -0.2247 40% Void Hot Operating 80 TModerator-550 F TFuel=935 0 F 0.77202 1.04110 -0.2585 80% Void Table 2.49 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter - ko Parameter ko k. ko (Ak/k)
Doppler kHotOperatingNoXe- kHotStandby 1.08504 1.08985 -0.0044 kHotStandby Moderatorvoid =kHotOperating40 - kHotOperatingo 1.06587 1.08504 -0.0177 kHotOperatingo kHotStandby - kCold 1.08985 1.12686 -0.0328 ModeratorTemerture = kcoCjd AREVA NP Inc.
Contro[led Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-48 Table 2.50 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = 'kControlled - kUncontrolled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k)
Cold TModerator= 6 80 F TFel=68 0 F 0.93517 1.10220 -0.1515 0% Void, No xenon 2 0 0 0 Intermediate TModerator= F TFuei=200° F 0.92110 1.09417 -0.1582 0% Void, No xenon Hot Standby TModerator=550 F TFuel=550 0 F 0.86576 1.06417 -0.1865 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=935 0 F 0.86194 1.05951 -0.1865 0% Void, No xenon Hot Operatingo TModerator=550° F TFueI=935 0 F 0.86200 1.05951 -0.1864 0% Void Hot Operating 4o TModerator=550° F TFuel=935° F 0.82318 1.04216 -0.2101 40% Void Hot Operating 80 TModerator=5500 F TFuel=935 0 F 0.77644 1.01931 -0.2383 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-49 Table 2.51 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kCantrolled - kuncontralled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k)
Cold TModerator=
6 8 0 F TFuel=68 0 F 0.93655 1.10220 -0.1503 0% Void, No xenon 00 Intermediate TModerator=2 0 F TFuel=200 0 F 0.92258 1.09417 -0.1568 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550 0 F 0.86727 1.06417 -0.1850 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TFue=935° F 0.86346 1.05951 -0.1850 0% Void, No xenon 0
Hot Operating 0 TModerator=550 F TFuel=935° F 0.86352 1.05951 -0.1850 0% Void Hot Operating 40 TModerato'-550° F TFuel=935 0 F 0.82433 1.04216 -0.2090 40% Void Hot Operating 80 TModerator=5500 F TFuel=935 0 F 0.77689 1.01931 -0.2378 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-50 Table 2.52 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator=
6 8 0 F TFuel=68 0 F 0.93181 1.10220 -0.1546 0% Void, No xenon Intermediate TModerator= 20 00 F TFue=200 0 F 0.91755 1.09417 -0.1614 0% Void, No xenon Hot Standby TModerator=550° F TFU 8l=550° F 0.85997 1.06417 -0.1919 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFueI=935 0 F 0.85620 1.05951 -0.1919 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel=935 0 F 0.85620 1.05951 -0.1919 0% Void Hot Operating 4o TModerator=550 F TFueI=935 0 F 0.81492 1.04216 -0.2180 40% Void TFueI=935 0 0
Hot Operating 80 TModerator=55 0 F F 0.76462 1.01931 -0.2499 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-51 Table 2.53 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcontrolled - kuncontrolled Worth kUncontrolled kControlled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.93166 1.10220 -0.1547 0% Void, No xenon 20 00 Intermediate TModerator= F TFuej=200° F 0.91763 1.09417 -0.1613 0% Void, No xenon Hot Standby TModerator=
5 5 0 0 F TFueI=550° F 0.86119 1.06417 -0.1907 0% Void, No xenon Hot OperatingNoXe TModerator=5500 F TFuel=935° F 0.85740 1.05951 -0.1908 0% Void, No xenon Hot Operatingo TModerator=55 0
° F TFuel=935 0 F 0.85745 1.05951 -0.1907 0% Void 0 F TFuel=935 0 0
Hot Operating 40 TModerator=55 F 0.81723 1.04216 -0.2158 40% Void 0
Hot Operating 80 TModerator=550 F TFuel=935 0 F 0.76886 1.01931 -0.2457 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-52 Table 2.54 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 80 Cold TModeramtor=6 F TFuel=68 0 F 0.92832 1.10220 -0.1578 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFue,=200 0 F 0.91420 1.09417 -0.1645 0% Void, No xenon Hot Standby TModerator=550 0
F TFuel=550 0 F 0.85675 1.06417 -0.1949 0% Void, No xenon Hot OperatingNoxe TModerator-550° F TFuel=935° F 0.85300 1.05951 -0.1949 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=935 0 F 0.85305 1.05951 -0.1949 0% Void Hot Operating 40 TModerator=5500 F TFue,=935 0 F 0.81151 1.04216 -0.2213 40% Void Hot Operating 80 TModerator=550 F TFueI=9 35° F 0.76111 1.01931 -0.2533 80% Void Table 2.55 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter -k ko Parameter ko k. ko (Ak/k)
Doppler = kHotOperafingNoXe - kHotStandby 1.05951 1 .06417 -0.0044 kHotStandby Moderatorvid = IkHotOperating40 - kHatOperafingo 1.04216 1.05951 -0.0164 kHotOperatingO kcold 1.06417 1.10220 -0.0345 moderatorTempmture - kHotStandby -
kCold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-53 Table 2.56 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kCantrolled - kuncontrfled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 8 0 0 Cold Tmoderator= F TFueI=68 F 0.90472 1.07296 -0.1568 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel=200 0 F 0.89247 1.06791 -0.1643 0% Void, No xenon Hot Standby TModerator=
5 5 0
° F TFuel=550 0 F 0.84507 1.04920 -0.1946 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TFuel=995 0 F 0.84127 1.04451 -0.1946 0% Void, No xenon Hot Operating 0 TModerator=550 F TFue=995 0 F 0.84133 1.04451 -0.1945 0% Void Hot Operating 4o TModerator=550 F TFuel=995 0 F 0.80430 1.03218 -0.2208 40% Void Hot Operating 80 TModerator--550 F TFue=995 0 F 0.75443 1.01204 -0.2545 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-54 Table 2.57 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontmlled - kuncontrolled Worth kUncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 8 0 F TFuel=68 0 F 0.90624 1.07296 -0.1554 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFuej=200° F 0.89414 1.06791 -0.1627 0% Void, No xenon 5 5 0 Hot Standby TModerator= ° F TFuel=550 0 F 0.84688 1.04920 -0.1928 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=995 0 F 0.84308 1.04451 -0.1928 0% Void, No xenon Hot Operating 0 TModerator=5500 F TFueI=995 0 F 0.84314 1.04451 -0.1928 0% Void Hot Operating 40 TModerator=5500 F TFuel=995 0 F 0.80580 1.03218 -0.2193 40% Void 9 0 Hot Operating 80 TModerator=550° F TFuel=9 5 F 0.75529 1.01204 -0.2537 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-55 Table 2.58 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip) kcantrolled - kunoonlfrolled Blade Worth Blade Worth =
kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.90154 1.07296 -0.1598 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=200 0 F 0.88917 1.06791 -0.1674 0% Void, No xenon Hot Standby TModerator=550° F TFue=5500 F 0.83975 1.04920 -0.1996 0% Void, No xenon Hot OperatingNox, TModerator=550° F TFue,=995 0 F 0.83600 1.04451 -0.1996 0% Void, No xenon Hot Operating 0 TModerator= 5 5 0 0 F TFueI=9956 F 0.83600 1.04451 -0.1996 0% Void Hot Operating 40 TModerator=550 F TFue,=995 0 F 0.79645 1.03218 -0.2284 40% Void Hot Operating 80 TModerator=550° F TFuei=995 0 F 0.74276 1.01204 -0.2661 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-56 Table 2.59 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade kControlled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (AkWk)
Cold TModerator=6 80 F TFueI=6 8 0 F 0.90093 1.07296 -0.1603 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel= 2 0 0 0 F -0.1678 0% Void, No xenon 5 5 0 0 Hot Standby TModerator= F TFuel=550° F -0.1990 0% Void, No xenon Hot OperatingNoxe TModerator=
5 5 0
- F TFuel= 9 9 5 ' F -0.1990 0% Void, No xenon 5 5 Hot Operating 0 TModerator= O0 F TFueI=995° F -0.1989 0% Void Hot Operating 40 TModerator=
5 5 0 0 F TFueI=995° F -0.2267 40% Void Hot Operating 80 TModerator=
5 5 O
0 F TFuej=995 0 F -0.2623 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-57 Table 2.60 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantrolled - kUncontrolled Worth kuncontroaied kcontrolled kuncontrolled (Ak/k)
Cold TModerator=6 8 0 F TFuel= 6 80 F 0.89767 1.07296 -0.1634 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=2 00 0 F 0.88542 1.06791 -0.1709 0% Void, No xenon Hot Standby TModerator= 5 500 F TFuel-5500 F 0.83613 1.04920 -0.2031 0% Void, No xenon Hot OperatingNoxe TModerator= 5 50
° F TFueI=9 9 5° F 0.83240 1.04451 -0.2031 0% Void, No xenon Hot Operatingo TModerator=550° F TFueI=995° F 0.83245 1.04451 -0.2030 0% Void 0 99 Hot Operating 4o TModerator550 F TFuel= 50 F 0.79259 1.03218 -0.2321 40% Void Hot Operating 80 TModerator=550° F TFueI=995 0 F 0.73881 1.01204 -0.2700 80% Void Table 2.61 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter- k.-ký Parameter ko ký ko (Ak/k)
=kHotOperatingNoXe - kHotStandby 1.04451 1.04920 -0.0045 Doppler kHotStandby kHotOperating40 - kHotOperatingo 1.03218 1.04451 -0.0118 Moderatorvoid MkHotOperatingO kHotStandby - kcold 1.04920 1.07296 -0.0221 ModeratorTemture = kold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 10XM Fuel Page 2-58 Table 2.62 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth kcontrolled - kUncontrolled Worth Wot kuncontrolled kcontrolled kUncontrolied (Ak/k)
Cold TModerator= 6 80 F TFuel=68 0 F 0.91545 1.08432 -0.1557 0% Void, No xenon 2 000 Intermediate TModerator= F TFuel= 2 00 0 F 0.90385 1.08011 -0.1632 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.85979 1.06608 -0.1935 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFue,=995 0 F 0.85599 1.06140 -0.1935 0% Void, No xenon Hot Operating 0 TModerator=550° F TFue,=9 95 0 F 0.85605 1.06140 -0.1935 0% Void Hot Operating 40 TModerator=550 F TFue,=995 0 F 0.82028 1.05150 -0.2199 40% Void Hot Operating 80 TModerator=55 0 F TFue,=995 0 F 0.77141 1.03458 -0.2544 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-59 Table 2.63 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontrojed - kuncontoI&ed Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerto*= F TFueI=68 0 F 0.91695 1.08432 -0.1543 0% Void, No xenon Intermediate TModerator= 2 000 F TFuel=200 0 F 0.90550 1.08011 -0.1617 0% Void, No xenon Hot Standby TModerator=550° F TFue,=550 0 F 0.86159 1.06608 -0.1918 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TFuel=995 0 F 0.85779 1.06140 -0.1918 0% Void, No xenon Hot Operatingo TModerator=55 0 F TFue,=995 0 F 0.85785 1.06140 -0.1918 0% Void Hot Operating 40 TModerator=550° F TFul,=995 0
F 0.82176 1.05150 -0.2185 40% Void Hot Operating 80 TModerator=550 F TFeI=995' F 0.77222 1.03458 -0.2536 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-60 Table 2.64 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kuncntjrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator=68 0 F TFueI=68 0 F 0.91222 1.08432 -0.1587 0% Void, No xenon Intermediate TModerator=2 000 F TFuel=200 0 F 0.90061 1.08011 -0.1662 0% Void, No xenon Hot Standby TModerator=55 0
° F TFuel=550 0 F 0.85436 1.06608 -0.1986 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=995° F 0.85061 1.06140 -0.1986 0% Void, No xenon Hot Operating 0 TModerator=5500 F TFueI=995 0 F 0.85061 1.06140 -0.1986 0% Void Hot Operating 40 TModerator=550° F TFuel=995 0 F 0.81222 1.05150 -0.2276 40% Void Hot Operating 80 TModerator=5500 F TF,,e=995 0 F 0.75933 1.03458 -0.2661 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-61 Table 2.65 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth= kc-ontrolled - kUncntolled Worth kuncontr°lled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68° F 0.91162 1.08432 -0.1593 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFueI=200 0 F 0.90009 1.08011 -0.1667 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.85507 1.06608 -0.1979 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFueI=995 0 F 0.85131 1.06140 -0.1979 0% Void, No xenon Hot Operating0 TModerator=550° F TFueI=995 0 F 0.85136 1.06140 -0.1979 0% Void Hot Operating 40 TModerator=550 F TFuej=995) F 0.81402 1.05150 -0.2258 40% Void Hot Operating 8 0 TModerator=550 0 F TFuel=995 0 F 0.76324 1.03458 -0.2623 80% Void AREVA NP Inc.
Controlled Document ANP-3139(NP)
Nuclear Fuel Design Report Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-62 Table 2.66 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade kcantrolled - kUncntr.lled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFueI=68 0 F 0.90831 1.08432 -0.1623 0% Void, No xenon Intermediate TModerator=
2 0 0 0 F TFueI=200 0 F 0.89670 1.08011 -0.1698 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.85068 1.06608 -0.2021 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFue=995 0 F 0.84695 1.06140 -0.2020 0% Void, No xenon Hot Operating 0 TModerator=550 0
F TFuel=995 0 F 0.84700 1.06140 -0.2020 0% Void Hot Operating 4o TModerator--550 F TFuel=995 0 F 0.80827 1.05150 -0.2313 40% Void Hot Operating 80 TModerator=550° F TFueI=995 0 F 0.75526 1.03458 -0.2700 80% Void Table 2.67 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter -k Parameter ko k. ko (Ak/k) 1.06140 1.06608 -0.0044 Doppler kHotOperatjngNoXe - kHotStandby kHotStandby 1.05150 1.06140 -0.0093 Moderatorvoid = kHotOperafingO - kHotOperatingO kHotOperang 0 O kcold 1.06608 1.08432 -0.0168 Moderator rTemperature = kcold-kHotStandby AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-63 Table 2.68 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade o
kcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 80 Cold TModerator= 6 F TFueI=68 0 F 0.97632 1.14764 -0.1493 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200 0 F 0.96298 1.14104 -0.1560 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550° F 0.90645 1.11247 -0.1852 0% Void, No xenon Hot OperatingNoxe TModeeator=5500 F TFuel=935° F 0.90238 1.10755 -0.1852 0% Void, No xenon Hot Operatingo TModerator=550° F TFueI=935° F 0.90245 1.10755 -0.1852 0% Void Hot Operating 4o TModerator=5500 F TFueI=935 0 F 0.85847 1.08726 -0.2104 40% Void Hot Operating 80 TModerator=5500 F TFuel=935 0 F 0.80446 1.06087 -0.2417 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-64 Table 2.69 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontrolled - kUncontrmlled Worth kuncontrolled kControlled kUncontrolled (Ak/k)
Cold TModerator= 6 8 0 F TFuel=68 0 F 0.97754 1.14764 -0.1482 0% Void, No xenon Intermediate TModerator=
2 0 00 F TFueI=200 0 F 0.96431 1.14104 -0.1549 0% Void, No xenon Hot Standby TModerator=550 F TFuel=550 0 F 0.90786 1.11247 -0.1839 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuej=935° F 0.90381 1.10755 -0.1840 0% Void, No xenon Hot Operatingo TModerator=5500 F TFuel=935° F 0.90387 1.10755 -0.1839 0% Void Hot Operating 40 TModerator=550° F TFueI=935 0 F 0.85958 1.08726 -0.2094 40% Void 0
Hot Operating 80 TModerator=550 F TFuel=935° F 0.80497 1.06087 -0.2412 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 10XM Fuel Page 2-65 Table 2.70 Lattice[ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kControlled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68 0 F 0.97251 1.14764 -0.1526 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFuel=200 0 F 0.95895 1.14104 -0.1596 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550 0 F 0.90001 1.11247 -0.1910 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFueI=935 0 F 0.89600 1.10755 -0.1910 0% Void, No xenon Hot Operatingo TModerator=550° F TFuel=935 0 F 0.89600 1.10755 -0.1910 0% Void Hot Operating 40 TModerator=550 F TFueI=935 0 F 0.84946 1.08726 -0.2187 40% Void Hot Operating 80 TModerator=550° F TFuel=935 0 F 0.79187 1.06087 -0.2536 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-66 Table 2.71 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = IkControlled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel=68 0 F 0.97252 1.14764 -0.1526 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFuel=200 0 F 0.95920 1.14104 -0.1594 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550 0 F 0.90145 1.11247 -0.1897 0% Void, No xenon Hot OperatingNoxe TModerator"550° F TFue =935 1
0 F 0.89743 1.10755 -0.1897 0% Void, No xenon Hot Operating 0 TModerator=55 0
° F TFuel=935 0 F 0.89748 1.10755 -0.1897 0% Void Hot Operating 40 TModerator=550 F TFuel=935° F 0.85200 1.08726 -0.2164 40% Void Hot Operating 80 TModerator=5500 F TFu.1=935° F 0.79630 1.06087 -0.2494 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-67 Table 2.72 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kcantrolled - kuncontrlled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 80 Cold TModerator= 6 F TFuel=68a F 0.96892 1.14764 -0.1557 0% Void, No xenon 0 00 Intermediate TModerator= 2 F TFueI=200° F 0.95550 1.14104 -0.1626 0% Void, No xenon Hot Standby TModerator=550° F TFuel=5500 F 0.89669 1.11247 -0.1940 0% Void, No xenon Hot OperatingNoxe TModerator=-550 F TFuel=935 0 F 0.89270 1.10755 -0.1940 0% Void, No xenon Hot Operating 0 TModerator=550° F TFuel=935 0 F 0.89276 1.10755 -0.1939 0% Void Hot Operating 4o TModerator=550 F TFuel=935 0 F 0.84591 1.08726 -0.2220 40% Void Hot Operating 80 TModerator=550 F TFueI=935 0 F 0.78815 " 1.06087 -0.2571 80% Void Table 2.73 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = - Parameter ko k. ko (Ak/k) 1.10755 1.11247 -0.0044 Doppler kHotOperatingNoXe - kHotStandby kHotStandby 1.08726 1.10755 -0.0183 Moderatorvld kHotOperating4O - kHotOperatingo okHotOperatingO
_ kHotStandby - kCold 1.11247 1.14764 -0.0307 ModeratorTemprature - kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-68 Table 2.74 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kcontrolled - kuncontrolled Worth kuncontr-lled kControlled kuncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel= 6 8 0 F 0.95600 1.12248 -0.1483 0% Void, No xenon Intermediate TModerator=2 0 0 0 F TFuel=200 0 F 0.94246 1.11515 -0.1549 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550° F 0.88701 1.08599 -0.1832 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel=935° F 0.88308 1.08123 -0.1833 0% Void, No xenon Hot Operatingo TModerator=550° F TFueI=935 0 F 0.88314 1.08123 -0.1832 0% Void Hot Operating 40 TModerator=550 F TFUel=935 0 F 0.84210 1.06260 -0.2075 40% Void Hot Operating 80 TModerator=550 F TFue=935 0 F 0.79208 1.03797 -0.2369 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-69 Table 2.75 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontroled - kUncCntrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68° F 0.95734 1.12248 -0.1471 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFueI=2 00 0 F 0.94392 1.11515 -0.1535 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550° F 0.88850 1.08599 -0.1819 0% Void, No xenon Hot OperatingNoxe TModerator=55 0
° F TFue=935 0 F 0.88458 1.08123 -0.1819 0% Void, No xenon Hot Operating 0 TModerator=550 F TFue1=935 0 F 0.88464 1.08123 -0.1818 0% Void Hot Operating 40 TModerator=550 F TFue=935 0 F 0.84324 1.06260 -0.2064 40% Void Hot Operating 80 TModerator=5500 F TFuel=935 0 F 0.79253 1.03797 -0.2365 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-70 Table 2.76 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kCntrled - kUnc°ntrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator=6 80 F TFuel=68 0 F 0.95258 1.12248 -0.1514 0% Void, No xenon 2 0 0 0 Intermediate TModerator= F TFuel=200 0 F 0.93886 1.11515 -0.1581 0% Void, No xenon Hot Standby TModerator=5500 F TFueI=550 0 F 0.88109 1.08599 -0.1887 0% Void, No xenon Hot OperatingNoxe TModerator=5500 F TFue=935° F 0.87721 1.08123 -0.1887 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=935- F 0.87721 1.08123 -0.1887 0% Void Hot Operating 40 TModerator=550 F TFue=935° F 0.83363 1.06260 -0.2155 40% Void Hot Operating 80 TModerator=550° F TFueI=935 0 F 0.77998 1.03797 -0.2485 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-71 Table 2.77 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcaCntmoled - kUncontmled Worth kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 8 0 Cold TModerator= F TFueI=68 0 F 0.95253 1.12248 -0.1514 0% Void, No xenon 0 00 Intermediate TModerator=2 F TFue1=200 0 F 0.93903 1.11515 -0.1579 0% Void, No xenon Hot Standby TModerator=5500 F TFuel=550 0 F 0.88243 1.08599 -0.1874 0% Void, No xenon Hot OperatingNoxe TModerator=55 0
° F TFueI=935° F 0.87853 1.08123 -0.1875 0% Void, No xenon Hot Operatingo TModerator=550° F TFue=935° F 0.87858 1.08123 -0.1874 0% Void 0
Hot Operating 40 TModerator=550 F TFue,=935 0 F 0.83607 1.06260 -0.2132 40% Void Hot Operating 80 TModerator=550° F TFueI=935 0 F 0.78431 1.03797 -0.2444 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM' 10XM Fuel Page 2-72 Table 2.78 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kaCntrlled - kUncntrdlled Worth kuncontroned kControlled kUncontrolled (Ak/k)
Cold TModerator= 6 8
° F TFuel=68 0 F 0.94915 1.12248 -0.1544 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200 0 F 0.93557 1.11515 -0.1610 0% Void, No xenon Hot Standby TModerator=550 F TFuel=550 0 F 0.87792 1.08599 -0.1916 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFueI=935° F 0.87406 1.08123 -0.1916 0% Void, No xenon Hot Operatingo TModerator=550° F TFue=935 0 F 0.87411 1.08123 -0.1916 0% Void Hot Operating 4o TModerator=550° F TFueI=935 0 F 0.83024 1.06260 -0.2187 40% Void Hot Operating 80 TModerator=550° F TFueI=935° F 0.77641 1.03797 -0.2520 80% Void Table 2.79 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter =k - ký Parameter kK k. ko (Ak/k)
Doppler kHotOperatingNoXe - kHotStandby 1.08123 1.08599 -0.0044 kHotStandby Moderatorvoid kHotOperating4O - kHotOperatingO 1.06260 1.08123 -0.0172 kHotOperatbngO
_ kHotStandby - kCold 1.08599 1.12248 -0.0325 ModeratorTemerture - kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-73 Table 2.80 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kcontrolled - kuncntrolled Worth kuncontrolled kControlled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFuel=68- F 0.92550 1.09369 -0.1538 0% Void, No xenon 000 Intermediate TModerator=2 F TFuel=200 0 F 0.91409 1.08961 -0.1611 0% Void, No xenon Hot Standby TModerator-55O 0
F TFuel=5500 F 0.86760 1.07275 -0.1912 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=995 0 F 0.86367 1.06794 -0.1913 0% Void, No xenon.
Hot Operating 0 TModerator=550° F TFue=995 0 F 0.86374 1.06794 -0.1912 0% Void Hot Operating 40 TModerator=550° F TFuel=995° F 0.82507 1.05501 -0.2180 40% Void Hot Operating 80 TModerator--550 F TFueI=995 0 F 0.77268 1.03416 -0.2528 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-74 Table 2.81 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFueI=68 0 F 0.92700 1.09369 -0.1524 0% Void, No xenon 2 0 00 Intermediate TModerator= F TFuel=200 0 F 0.91575 1.08961 -0.1596 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.86941 1.07275 -0.1895 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFueI=995- F 0.86549 1.06794 -0.1896 0% Void, No xenon Hot Operatingo TModerator= 55 0 F TFuI=9950 F 0.86556 1.06794 -0.1895 0% Void Hot Operating 40 TModerator=550 F TFueI=995 0 F 0.82658 1.05501 -0.2165 40% Void Hot Operating 80 TModerator=550° F TFueI=995 0 F 0.77356 1.03416 -0.2520 80% Void AREVA NP Inc.
Contro~led Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-75 Table 2.82 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcontrolled - kUncontrolled Worth kUncontrolled kcontrolled kUncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68° F 0.92227 1.09369 -0.1567 0% Void, No xenon Intermediate TModeato,=2 0 0 0 F TFueI=200 0 F 0.91074 1.08961 -0.1642 0% Void, No xenon Hot Standby TModerator=550 F TFueI=550° F 0.86215 1.07275 -0.1963 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFueI=995 0 F 0.85829 1.06794 -0.1963 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=995 0 F 0.85829 1.06794 -0.1963 0% Void Hot Operating 40 TModerator=550° F TFueI=995° F 0.81701 1.05501 -0.2256 40% Void Hot Operating 80 TModerator=550 F TFuel=995° F 0.76069 1.03416 -0.2644 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-76 Table 2.83 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcontroled - kuncontrotled Worth kuncontrolled kControlled kuncontrolled (Ak/k)
Cold TModerator=68 0 F TFuel= 6 8 ° F 0.92175 1.09369 -0.1572 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel= 2 0 00 F 0.91043 1.08961 -0.1644 0% Void, No xenon 0
Hot Standby TModerator=550° F TFuel=55 ° F 0.86296 1.07275 -0.1956 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel= 9 9 5° F 0.85908 1.06794 -0.1956 0% Void, No xenon Hot Operating 0 TModeator=5500 F TFuel=995' F 0.85913 1.06794 -0.1955 0% Void Hot Operating 40 TModerator=550° F TFuel= 9 9 50 F 0.81889 1.05501 -0.2238 40% Void Hot Operating 80 TModerator=5500 F TFuel= 9 9 5° F 0.76462 1.03416 -0.2606 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-77 Table 2.84 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth = kControlled - kuncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFuel=68 0 F 0.91844 1.09369 -0.1602 0% Void, No xenon Intermediate TModerator=2 0 00 F TFuel=200° F 0.90703 1.08961 -0.1676 0% Void, No xenon 0
Hot Standby TMod..ato.,=55 F TFuei=550° F 0.85857 1.07275 -0.1997 0% Void, No xenon Hot OperatingNoXe TModerator=550° F TFuel=995 0 F 0.85472 1.06794 -0.1997 0% Void, No xenon Hot Operating 0 TModerator=550° F TFueI=995° F 0.85477 1.06794 -0.1996 0% Void Hot Operating 40 TModerator=550° F TFueI=995 0 F 0.81314 1.05501 -0.2293 40% Void Hot Operating 80 TModerator=550° F TFue,=995 0 F 0.75666 1.03416 -0.2683 80% Void Table 2.85 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter -kk k Parameter ko k. ko (Ak/k) 1.06794 1.07275 -0.0045 Doppler kHotOperatingNoXe - kHotStandby kHotStandby Moderatorvoid kHotOperating4O - kHotOperatingo 1.05501 1.06794 -0.0121 kHotOperatingO kHotStandby - kcoad 1.07275 1.09369 -0.0192 Moderatorremprture = kcold AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-78 Table 2.86 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Original Equipment Blade Blade Worth = kControlled - kUncontrolled Worth kUncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerato= 6 8 0 F TFueI=6 80 F 0.96582 1.12874 -0.1443 0% Void, No xenon Intermediate TModerator= 2 0 0 0 F TFueI=200 0 F 0.95555 1.12602 -0.1514 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550 0 F 0.91125 1.11442 -0.1823 0% Void, No xenon Hot OperatingNexe TModerator-550° F TFuel= 9 95° F 0.90721 1.10951 -0.1823 0% Void, No xenon 50 9 9 Hot Operating 0 TModerator=550° F TFuel= F 0.90728 1.10951 -0.1823 0% Void Hot Operating 4o TModerator=550° F TFuel=995 0 F 0.86717 1.09804 -0.2103 40% Void 0
Hot Operating 80 TModerator=550° F TFueI=9 9 5 F 0.81153 1.07822 -0.2473 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-79 Table 2.87 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Main Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth kuncontrolled kcontrolled kUncontrolled (Ak/k)
Cold TModerator= 6 80 F TFueI=68 0 F 0.96719 1.12874 -0.1431 0% Void, No xenon 2 000 Intermediate TModerator= F TFueI=200 0 F 0.95708 1.12602 -0.1500 0% Void, No xenon Hot Standby TModerator=
5 500 F TFuel=550 0 F 0.91294 1.11442 -0.1808 0% Void, No xenon Hot OperatingNoXe TModerator=
5 5 0
° F TFuel=995 0 F 0.90891 1.10951 -0.1808 0% Void, No xenon Hot Operating 0 TModerator=550 F TFueI=995 0 F 0.90897 1.10951 -0.1807 0% Void Hot Operating 40 TModerator=550 0
F TFueI=995 0 F 0.86851 1.09804 -0.2090 40% Void Hot Operating 80 TModerator=5500 F TFueI=995° F 0.81218 1.07822 -0.2467 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-80 Table 2.88 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Duralife 140a (Hafnium Tip)
Blade Blade Worth = kcantrolled - kUncontralled Worth ot kuncontrolled kcontrolled kuncontrolled (Ak/k) 6 80 Cold TModerator= F TFueI=68 0 F 0.96270 1.12874 -0.1471 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFueI=200 0 F 0.95231 1.12602 -0.1543 0% Void, No xenon Hot Standby TModerator=550° F TFuel=550 0 F 0.90580 1.11442 -0.1872 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel=995° F 0.90181 1.10951 -0.1872 0% Void, No xenon Hot Operatingo TModerator=550 F TFuel=995 0 F 0.90181 1.10951 -0.1872 0% Void Hot Operating 4o TModerator=550° F TFueI=995° F 0.85886 1.09804 -0.2178 40% Void Hot Operating 80 Tmoderator=5500 F TFueI=995 0 F 0.79887 1.07822 -0.2591 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page 2-81 Table 2.89 Lattice [ ] Control Blade Worths at BOL for Control Blade Type GE Marathon (Bottom Section)
Blade Blade Worth = kcontrolled - kUnlcontroled Worth kuncontroed kcontrolled kUncontrolled (Ak/k) 80 Cold TModerator= 6 F TFuel=68 0 F 0.96226 1.12874 -0.1475 0% Void, No xenon Intermediate TMderator=200 0 F TFueI=200 0 F 0.95207 1.12602 -0.1545 0% Void, No xenon Hot Standby TModerator=550° F TFueI=550 0 F 0.90669 1.11442 -0.1864 0% Void, No xenon Hot OperatingNoxe TModerator=550° F TFuel= 9 95 0 F 0.90269 1.10951 -0.1864 0% Void, No xenon 0
Hot Operating 0 TModerator=55 0
° F TFuel= 9 9 5 F 0.90274 1.10951 -0.1864 0% Void Hot Operating 4o TModerator=
5 5 0
° F TFue=995 0 F 0.86091 1.09804 -0.2160 40% Void Hot Operating 80 TModerator=550° F TFue=995 0 F 0.80310 1.07822 -0.2552 80% Void AREVA NP Inc.
Controlled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-82 Table 2.90 Lattice [ I Control Blade Worths at BOL for Control Blade Type GE Marathon (Main Section)
Blade Blade Worth kcontrolled - kuncontrolled Worth
'kUncontrolled kcontrolled kUncontrolled (A'(k) 80 Cold TModerator=6 F TFueI=68 0 F 0.95901 1.12874 -0.1504 0% Void, No xenon Intermediate TModerator= 2 0 00 F TFuel=200 0 F 0.94873 1.12602 -0.1575 0% Void, No xenon Hot Standby TModerator=550 F TFuel'550 0 F 0.90227 1.11442 -0.1904 0% Void, No xenon Hot OperatingNoxe TModerator=550 F TFuel=995° F 0.89830 1.10951 -0.1904 0% Void, No xenon Hot Operating 0 TModerator=550 F TFuel=995 0 F 0.89836 1.10951 -0.1903 0% Void Hot Operating 40 TModerator=5500 F TFuel=995 0 F 0.85502 1.09804 -0.2213 40% Void Hot Operating 80 TModerator=5500 F TFuel=995° F 0.79482 1.07822 -0.2628 80% Void Table 2.91 Lattice [ ] Kinetics Parameters at BOL Kinetics Kinetics Parameter = k' Parameter ko k. ký (Ak/k)
Doppler kHotOperatingNoXe - kHotStandby 1.10951 1.11442 -0.0044 (kHotStandby (kHotOperating4O- kHotOperatingO 1.09804 1.10951 -0.0103 Moderatorvoid = (kHotOperatingo S-(kHotStandby - kcold 1.11442 1.12874 -0.0127 ModeratorTemperature = (kcold AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-83
[
I Figure 2.1 Assembly Type [ I AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-84
[
I Figure 2.2 Assembly Type [ I AREVA NP Inc.
Luontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UMTM1 1OXM Fuel Page 2-85
[
I Figure 2.3 Assembly Type [
AREVA NP Inc.
uontroiled uocument Nucle.ar FueIl Desian Renort ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-86 1 2 3 4 5 5 6 4 3 7 IiL 2 3 8 6 9 10 9 10 5 3 3 8 5 6 11 12 11 10 9 13 4 6 6 13 10 10 14 15 10 6 5 9 11 10 11 9 10 5 10 12 10 Water Channel 5 10 10 6 9 11 14 11 9 6 4 10 10 15 11 5 11 16 10 5 3 5 9 10 9 10 9 10 5 3 7 3 13 6 10 10 6 5 3 7 Fuel Rod Type Quantity Fuel Rod Type Quantity 1 1 9 10 2 2 10 20 3 9 11 8 4 4 12 2 5 12 13 3 6 10 14 2 7 3 15 2 8 2 16 1 Figure 2.4 [ ] Fuel Rod Distribution AREVA NP Inc.
(Jontrolled uocument Nuclear FueI r1loesinn RPonnrt ANP-3139(NP)
Monticello Cycle 28 Revision I ATRIUM TM 1OXM Fuel Page 2-87 JLJ 1 2 3 4 5 5 6 4 3 7 2 3 8 6 9 10 9 10 5 3 3 8 5 6 11 12 11 10 9 13 4 6 6 13 10 10 14 15 10 6 5 9 11 10 11 9 10 5 10 12 10 Water Channel 5 10 10 6 9 11 14 11 9 6 4 10 10 15 11 5 11 10 10 5 3 5 9 10 9 10 9 10 5 3 7 3 13 6 10 10 6 5 3 7 Fuel Rod Type Quantity Fuel Rod Type Quantity 1 1 9 10 2 2 10 21 3 9 11 8 4 4 12 2 5 12 13 3 6 10 14 2 7 3 15 2 8 2 Figure 2.5 [ ] Fuel Rod Distribution AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UMTM 1OXM Fuel Page 2-88 I1 1 2 3 4 5 5 6 4 3 7 2 3 8 6 9 10 9 10 5 3 3 8 5 6 11 12 11 10 9 13 4 6 6 13 10 10 14 15 10 6 5 9 11 10 11 10 10 5 10 12 10 Water Channel 5 10 10 6 9 11 14 11 9 6 4 10 10 15 11 5 11 16 10 5 3 5 9 10 10 10 9 10 5 3 7 3 13 6 10 10 6 5 3 7 Fuel Rod Type Quantity Fuel Rod Twye Quantity 1 1 9 8 2 2 10 22 3 9 11 8 4 4 12 2 5 12 13 3 6 10 14 2 7 3 15 2 8 2 16 1 Figure 2.6 [ ] Fuel Rod Distribution AREVA NP Inc.
Uontroiled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-89 Figure 2.7 Fuel Rod Axial Descriptions AREVA NP Inc.
Uontrolled Uooument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 2-90
[
I Figure 2.7 Fuel Rod Axial Descriptions (Continued)
AREVA NP Inc.
Uontrolled Vocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 3-1 3.0 References M
T
- 1. ANP-3092(P) Revision 0, Monticello Thermal-HydraulicDesign Report for A TRIUM IOXM Fuel Assemblies, AREVA NP, July 2012.
- 2. ANF-89-98(P)(A) Revision 1 and Supplement 1, Generic Mechanical Design Criteriafor BWR Fuel Designs, Advanced Nuclear Fuels Corporation, May 1995.
- 3. EMF-2158(P)(A), Revision 0, Siemens Power CorporationMethodology for Boiling Water Reactors: Evaluation and Validation of CASMO-4/MICROBURN-B2, Siemens Power Corporation, October 1999.
- 4. ANP-3113(P) Revision 0, Monticello Nuclear Plant Spent Fuel Storage Pool Criticality Safety Analysis for ATRIUM TM IOXM Fuel, AREVA NP, August 2012.
- 5. Letter, D. J. Mienke (Xcel Energy) to A. W. Will (AREVA), "Transmittal of Requested Monticello Cycle 28 Reload Design Information," OC-FAB-ARV-MN-XX-2012-013, March 26, 2012.
- 6. USNRC, "CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES," Certificate Number 9309, Revision 9, Docket Number 71-9309.
- 7. USNRC, "CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES," Certificate Number 9248, Revision 19, Docket Number 71-9248.
- 8. ANP-3119P Revision 0, MechanicalDesign Report for Monticello ATRIUM TM IOXM Fuel Assemblies, AREVA NP, October 2012.
AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-1 Appendix A Enriched Lattice Hot Uncontrolled Reactivity and LPF Plots The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA NP Inc.
uontroiied Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-2 1.20 1.15 1.10
"* 1.05 2 1.00 C
0 o 0.95 0.90 0.85 0.80 0.75 0 10 20 30 40 50 60 70 Lattice Exposure (GWdIMTU)
Figure A.1 [ ] Hot Uncontrolled k.
1.40 1.35 C
- 0) 1.30 (L
1.25
-J
" 1.20
)
C 1.15 0
1.10 1.05 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.2 [ ] Hot Uncontrolled LPF AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-3 1.20 1.15 1.10 1.05 750.91.00 C
0 0.90 0.85 0.75 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.3 [ ] Hot Uncontrolled k.
1.40 o61.35 U-C
- - 1.30 M 1.25 m
0.
_1.20 S1.15 0
= 1.10 1.05 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.4 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontroiied Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-4 1.30 1.20 "O 1.10 75 C1.00 0
0.90 0.80 0,70 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.5 [ ] Hot Uncontrolled k.
1.34 U. 1.29 1.24 a)
- 7. 1.19
- 0 1.14 1.09 1.04 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.6 [ ] Hot Uncontrolled LPF AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-5 1.30 1.20 0
a0 I.I0 S100 0
0.90 0.80 0.70 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.7 [ ] Hot Uncontrolled k.
1.29 r 1.24 1
S1.19 0
g
-J
-- 1.14 0
C C 1.09 1.04 10 20 30 40 so 60 70 Lattice Exposure (GWd/MTU)
Figure A.8 [ ] Hot Uncontrolled LPF AREVA NP Inc.
uontrolieci Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM MT 1OXM Fuel Page A-6 1.20 1.15 1.10 "0 1.05 I-~
0 u 0.95 C
0.90 0.85 0.80 0.75 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.9 [ ] Hot Uncontrolled k.
1.35 1.30
" 1.25 1.20
-J
,0 1.15 C
0U 1.10 LOS0 10 20 30 40 50 60 70 Lattice Exposure (GWdIMTU)
Figure A.10 [ ] Hot Uncontrolled LPF AREVA NP Inc.
u6ontroiied Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-7 1.20 1.15 1.10 "0 1.05 m 1.00 0
u 0.95 0.90 0.85 0.80 0.75 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.11 [ ] Hot Uncontrolled k, 1.40 0
1.35 L-
"*1.30 0
" 1.10 0
m 1.10 L.05 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.12 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontrolied Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-8 1.30 1.20 "O 1.10 C 1.00 0
0.90 0.80 0.70 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.13 [ ] Hot Uncontrolled k.
1.29 1.24
,u 0
1.1 0
,-J
_O 1.14 C
r 1.09 1.04 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.14 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontrollecl uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM MT 1OXM Fuel Page A-9 1.30 1.20 2
0 1.00 0
0.90 0.80 0.70 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.15 [ ] Hot Uncontrolled k, 1.29 18 1.24
'U "0
. 1.19
-J 0 1
,_ 1.14 0
0 C 1.09 1,04 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.16 [ ] Hot Uncontrolled LPF AREVA NP Inc.
uontroileci Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-10 1.20 1.15 1.10 11.05 0
o 0.95 0.90 0.85 0.75 0.75 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.17 [ ] Hot Uncontrolled k.
1.35 1.30 C
,m 1.25 (L
1.20 8 1.15 0
1.10 1.05 10 20 30 40 50 60 70 Lattice Expos u re (GWdlMTU)
Figure A.18 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontroiled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-11 1.20 1.15 1.10 1.05 2 1.00 0
o 0.95 0.90 0.85 0.80 0.75 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.19 [ ] Hot Uncontrolled k.
1.35 0
1.30 c 1.25 0)
~
- 0. 1.15 C
3 1.10 I.05 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.20 [ ] Hot Uncontrolled LPF AREVA NP Inc.
uontrollecl Uccument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page A-12 1.30 1.20
- O 1.10 S1.00 0
0.
0.90 0.80 0.70 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.21 [ ] Hot Uncontrolled k.
1.29 0
. 1.24 I. 1.19 1.
0
_0 1,14 U
r 1.09 1.04 0 10 20 30 40 50 60 70 Lattice Exposure (GWd/MTU)
Figure A.22 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontroliecl Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page A-13 1.30 1.20
- 1.10 0
C 1.00 0
U
.0.90 0.70 0 10 20 30 40 so 60 70 Lattice Exposure (GWd/MTU)
Figure A.23 [ ] Hot Uncontrolled k.
1.29 0
1.24 1.19 8
-J
- 1.14 C
0 C 1.09 1.04 0 10 20 30 40 50 60 70 Lattice Exposure (GWdlMTU)
Figure A.24 [ ] Hot Uncontrolled LPF AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-1 Appendix B Enriched Lattice Hot Uncontrolled Reactivity and LPF Tables The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA NP Inc.
(Jontrollea ULocument Niinclear Fiu I neinn Rennrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-2 Table B.1 ] Hot Uncontrolled k,,
Exposure 0.00 Void 0.40 Void 0.80 Void MfWd/MTrU History History History
- 0. 1.06448 1.04583 1.02214 100. 1.04139 1.02454 1.00341 500. 1.03895 1.02303 1.00297 1000. 1.03986 1.02464 1.00522 1500. 1.04174 1.02703 1.00796 2000. 1.04390 1.02957 1.01072 2500. 1.04608 1.03208 1.01334 3000. 1.04822 1.03448 1.01579 3500. 1.05038 1.03682 1.01810 4000. 1.05261 1.03915 1.02032 4500. 1.05492 1.04150 1.02248 5000. 1.05734 1.04390 1.02463 5500. 1.05987 1.04636 1.02678 6000. 1.06252 1.04891 1.02894 6500. 1.06531 1.05154 1.03114 7000. 1.06822 1.05426 1.03338 7500. 1.07127 1.05707 1.03568 8000. 1.07445 1.05997 1.03803 8500. 1.07776 1.06295 1.04044 9000. 1.08121 1.06602 1.04290 9500. 1.08481 1.06918 1.04541 10000. 1.08857 1.07245 1.04796 10500. 1.09248 1.07582 1.05055 11000. 1.09658 1.07931 1.05319 11500. 1.10086 1.08293 1.05587 12000. 1.10537 1.08668 1.05861 12500. 1.11014 1.09058 1.06140 13000. 1.11521 1.09465 1.06427 13500. 1.12060 1.09891 1.06722 14000. 1.12628 1.10337 1.07024 14500. 1.13229 1.10801 1.07335 15000. 1.13848 1.11280 1.07654 15500. 1.14459 1.11763 1.07978 16000. 1.15028 1.12235 1.08302 16500. 1.15529 1.12674 1.08620 17000. 1.15933 1.13058 1.08920 17500. 1.16216 1.13373 1.09192 18000. 1.16366 1.13604 1.09425 18500. 1.16381 1.13741 1.09613 19000. 1.16270 1.13782 1.09749 19500. 1.16052 1.13729 1.09827 20000. 1.15751 1.13590 1.09846 20500. 1.15389 1.13378 1.09804 21000. 1.14988 1.13105 1.09707 21500. 1.14538 1.12787 1.09559 22000. 1.14087 1.12436 1.09366 22500. 1.13637 1.12062 1.09135 23000. 1.13176 1.11656 1.08873 23500. 1.12715 1.11250 1.08585 24000. 1.12253 1.10845 1.08277 24500. 1.11792 1.10439 1.07955 25000. 1.11331 1.10033 1.07622 25500. 1.10869 1.09626 1.07282 26000. 1.10407 1.09219 1.06937 27500. 1.09020 1.07997 1.05880 30000. 1.06707 1.05979 1.04147 32500. 1.04390 1.03984 1.02450 35000. 1.02071 1.02012 1.00794 37500. 0.99754 1.00066 0.99180 40000. 0.97446 0.98147 0.97609 42500. 0.95156 0.96261 0.96083 45000. 0.92892 0.94413 0.94606 47500. 0.90669 0.92607 0.93178 50000. 0.88502 0.90851 0.91803 52500. 0.86407 0.89152 0.90483 55000. 0.84402 0.87517 0.89219 57500. 0.82503 0.85955 0.88013 60000. 0.80726 0.84471 0.86867 62500. 0.79083 0.83071 0.85780 65000. 0.77584 0.81761 0.84754 67500. 0.76234 0.80545 0.83790 70000. 0.75033 0.79423 0.82885 AREVA NP Inc.
Uontrolled uocument Mi P, ,i nfl*inn Piznnrt
,Indacr ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-3 Table B.2 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.366 1.360 1.340 100. 1.364 1.358 1.339 500. 1.360 1.353 1.335 1000. 1.355 1.348 1.330 1500. 1.349 1.343 1.325 2000. 1.343 1.337 1.321 2500. 1.338 1.332 1.316 3000. 1.332 1.326 1.311 3500. 1.327 1.321 1.307 4000. 1.321 1.316 1.302 4500. 1.316 1.310 1.298 5000. 1.310 1.305 1.293 5500. 1.305 1.299 1.288 6000. 1.299 1.294 1.284 6500. 1.293 1.288 1.279 7000. 1.287 1.283 1.275 7500. 1.281 1.277 1.270 8000. 1.275 1.272 1.265 8500. 1.268 1.266 1.261 9000. 1.262 1.260 1.256 9500. 1.256 1.255 1.251 10000. 1.249 1.249 1.247 10500. 1.243 1.243 1.242 11000. 1.236 1.238 1.237 11500. 1.229 1.232 1.232 12000. 1.222 1.226 1.228 12500. 1.216 1.220 1.223 13000. 1.209 1.214 1.218 13500. 1.202 1.209 1.213 14000. 1.195 1.203 1.209 14500. 1.188 1.197 1.204 15000. 1.180 1.191 1.199 15500. 1.173 1.185 1.194 16000. 1.166 1.179 1.190 16500. 1.159 1.173 1.185 17000. 1.153 1.167 1.181 17500. 1.147 1.161 1.176 18000. 1.142 1.156 1.172 18500. 1.137 1.151 1.167 19000. 1.133 1.147 1.163 19500. 1.129 1.143 1.159 20000. 1.126 1.139 1.156 20500. 1.124 1.136 1.152 21000. 1.121 1.133 1.149 21500. 1.119 1.131 1.146 22000. 1.116 1.128 1.144 22500. 1.114 1.126 1.141 23000. 1.112 1.124 1.139 23500. 1.110 1.122 1.137 24000. 1.108 1.120 1.135 24500. 1.106 1.118 1.134 25000. 1.104 1.116 1.132 25500. 1.103 1.114 1.130 26000. 1.102 1.112 1.129 27500. 1.100 1.106 1.124 30000. 1.096 1.097 1.117 32500. 1.093 1.088 1.109 35000. 1.090 1.085 1.102 37500. 1.088 1.083 1.096 40000. 1.086 1.080 1.090 42500. 1.083 1.077 1.084 45000. 1.080 1.073 1.078 47500. 1.075 1.070 1.074 50000. 1.071 1.067 1.076 52500. 1.066 1.064 1.088 55000. 1.060 1.060 1.101 57500. 1.055 1.057 1.113 60000. 1.049 1.055 1.126 62500. 1.052 1.072 1.138 65000. 1.073 1.089 1.151 67500. 1.093 1.105 1.163 70000. 1.112 1.121 1.175 AREVA NP Inc.
Uontrolled uocument Niucle.a*lr FueIl rlp..inn Rpnnrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-4 Table B.3 ] Hot Uncontrolled k Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.03924 1.02258 1.00098 100. 1.01733 1.00247 0.98345 500. 1.01579 1.00187 0.98395 1000. 1.01777 1.00453 0.98725 1500. 1.02071 1.00793 0.99098 2000. 1.02392 1.01149 0.99469 2500. 1.02717 1.01500 0.99824 3000. 1.03041 1.01842 1.00160 3500. 1.03371 1.02180 1.00482 4000. 1.03709 1.02519 1.00796 4500. 1.04060 1.02862 1.01105 5000. 1.04426 1.03213 1.01412 5500. 1.04809 1.03574 1.01719 6000. 1.05208 1.03945 1.02030 6500. 1.05623 1.04326 1.02346 7000. 1.06055 1.04718 1.02667 7500. 1.06506 1.05121 1.02995 8000. 1.06976 1.05535 1.03330 8500. 1.07469 1.05963 1.03671 9000. 1.07982 1.06405 1.04018 9500. 1.08518 1.06862 1.04372 10000. 1.09078 1.07336 1.04733 10500. 1.09665 1.07826 1A05101 11000. 1.10284 1.08335 1.05477 11500. 1.10939 1.08865 1.05862 12000. 1.11630 1.09418 1.06257 12500. 1.12358 1.09995 1.06661 13000. 1.13117 1.10592 1.07076 13500. 1.13891 1.11204 1.07499 14000. 1.14649 1.11817 1.07928 14500. 1.15351 1.12414 1.08356 15000. 1.15968 1.12965 1.08776 15500. 1.16475 1.13453 1.09176 16000. 1.16858 1.13861 1.09542 16500. 1.17101 1.14179 1.09863 17000. 1.17200 1.14400 1.10131 17500. 1.17165 1.14518 1.10339 18000. 1.17018 1.14534 1.10482 18500. 1.16785 1.14455 1.10561 19000. 1.16486 1.14297 1.10572 19500. 1.16139 1.14072 1.10521 20000. 1.15755 1.13797 1.10412 20500. 1.15345 1.13483 1.10250 21000. 1.14915 1.13138 1.10045 21500. 1.14474 1.12772 1.09803 22000. 1.14012 1.12390 1.09532 22500. 1.13549 1.11997 1.09237 23000. 1.13086 1.11597 1.08923 23500. 1.12622 1.11184 1.08597 24000. 1.12159 1.10772 1.08260 24500. 1.11695 1.10359 1.07917 25000. 1.11232 1.09946 1.07570 25500. 1.10770 1.09539 1.07219 27500. 1.08924 1.07909 1.05802 30000. 1.06613 1.05894 1.04069 32500. 1.04298 1.03901 1.02375 35000. 1.01980 1.01932 1.00721 37500. 0.99665 0.99987 0.99109 40000. 0.97359 0.98071 0.97540 42500. 0.95070 0.96187 0.96017 45000. 0.92810 0.94341 0.94541 47500. 0.90590 0.92538 0.93116 50000. 0.88426 0.90784 0.91743 52500. 0.86336 0.89088 0.90424 55000. 0.84336 0.87456 0.89163 57500. 0.82442 0.85896 0.87959 60000. 0.80669 0.84415 0.86814 62500. 0.79032 0.83019 0.85730 65000. 0.77538 0.81713 0.84706 67500. 0.76193 0.80499 0.83743 70000. 0.74997 0.79381 0.82841 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM M T
1OXM Fuel Page B-5 Table B.4 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.381 1.371 1.347 100. 1.378 1.369 1.345 500. 1. 374 1.364 1.341 1000. 1.368 1.358 1.335 1500. 1.362 1.352 1.330 2000. 1.355 1.346 1.325 2500. 1.349 1.340 1.320 3000. 1.342 1.334 1.315 3500. 1.336 1.328 1.310 4000. 1.329 1.321 1.305 4500. 1.323 1.315 1.300 5000. 1.316 1.309 1.295 5500. 1.310 1.303 1.290 6000. 1.303 1.297 1.285 6500. 1.296 1.290 1.279 7000. 1.289 1.284 1.274 7500. 1.281 1.278 1.269 8000. 1.274 1.271 1.264 8500. 1.267 1.265 1.259 9000. 1.259 1.258 1.254 9500. 1.252 1.252 1.249 10000. 1.244 1.245 1.243 10500. 1.236 1.239 1.238 11000. 1.229 1.232 1.233 11500. 1.221 1.226 1.228 12000. 1.213 1.219 1.222 12500. 1.205 1.212 1.217 13000. 1.196 1.206 1.212 13500. 1.188 1.199 1.207 14000. 1.180 1.192 1.202 14500. 1.173 1.186 1.196 15000. 1.166 1.179 1.191 15500. 1.159 1.173 1.186 16000. 1.154 1.167 1.181 16500. 1.148 1.162 1.177 17000. 1.144 1.158 1.172 17500. 1.140 1.153 1.168 18000. 1.137 1.149 1.164 18500. 1.134 1.146 1.161 19000. 1.131 1.143 1.157 19500. 1.129 1.140 1.155 20000. 1.126 1.138 1.152 20500. 1.124 1.135 1.149 21000. 1.122 1.133 1.147 21500. 1.120 1.131 1.145 22000. 1.118 1.129 1.143 22500. 1.115 1.127 1.141 23000. 1.113 1.125 1.140 23500. 1. 111 1.123 1.138 24000. 1.109 1.121 1.136 24500. 1.107 1.119 1.135 25000. 1.105 1.117 1.133 25500. 1.103 1.115 1.132 27500. 1.096 1.107 1.126 30000. 1.093 1.098 1.118 32500. 1.089 1.088 1. 111 35000. 1.085 1.082 1.104 37500. 1.083 1.080 1.097 40000. 1.081 1.077 1.091 42500. 1.078 1.074 1.085 45000. 1.074 1.070 1.080 47500. 1.070 1.068 1.078 50000. 1.069 1.066 1.077 52500. 1.068 1.063 1.089 55000. 1.065 1.060 1.101 57500. 1.061 1.057 1.114 60000. 1.054 1.055 1.126 62500. 1.053 1.073 1.139 65000. 1.074 1.090 1.151 67500. 1.094 1.106 1.164 70000. 1.112 1.122 1.175 AREVA NP Inc.
Uontrolled Uocument NI nclear Fiu11 Iefinn Rpnnrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-6 Table B.5 ] Hot Uncontrolled k0.
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.01928 1.00778 0.98971 100. 0.99639 0.98649 0.97088 500. 0 . 99440 0.98544 0.97095 1000. 0.99609 0.98789 0.97412 1500. 0.99904 0.99140 0.97801 2000. 1.00238 0.99521 0.98206 2500. 1.00581 0.99904 0.98602 3000. 1.00933 1.00286 0.98984 3500. 1.01299 1.00671 0.99356 4000. 1.01683 1.01064 0.99725 4500. 1.02085 1.01468 1.00095 5000. 1.02508 1.01886 1.00468 5500. 1.02953 1.02319 1.00845 6000. 1.03420 1.02768 1.01228 6500. 1.03909 1.03234 1.01619 7000. 1.04420 1.03715 1.02019 7500. 1.04953 1.04212 1.02429 8000. 1.05508 1.04723 1.02849 8500. 1.06087 1.05249 1.03279 9000. 1.06690 1.05792 1.03717 9500. 1.07320 1.06353 1.04164 10000. 1.07979 1.06934 1.04620 10500. 1.08670 1.07537 1.05086 11000. 1.09396 1.08162 1.05563 11500. 1.10164 1.08814 1.06050 12000. 1.10980 1.09495 1.06551 12500. 1.11854 1.10210 1.07066 13000. 1.12789 1.10965 1.07598 13500. 1.13769 1.11762 1.08147 14000. 1.14764 1.12592 1.08716 14500. 1.15740 1.13439 1.09303 15000. 1.16640 1.14264 1.09903 15500. 1.17408 1.15030 1.10504 16000. 1.18003 1.15695 1.11086 16500. 1.18409 1.16228 1.11622 17000. 1.18624 1.16611 1.12089 17500. 1.18651 1.16834 1.12471 18000. 1.18512 1.16900 1.12760 18500. 1.18243 1.16823 1.12949 19000. 1.17884 1.16628 1.13034 19500. 1.17436 1.16345 1.13020 20000. 1.16988 1.16001 1.12915 20500. 1.16496 1.15615 1.12733 21000. 1.16004 1.15177 1.12489 21500. 1.15511 1.14739 1.12199 22000. 1.15019 1.14300 1.11875 22500. 1.14527 1.13862 1.11528 23000. 1.14025 1.13416 1.11166 25000. 1.12018 1.11634 1.09629 27500. 1.09468 1.09399 1.07718 30000. 1.06876 1.07158 1.05830 32500. 1.04238 1.04910 1.03967 35000. 1.01556 1.02656 1.02128 37500. 0.98836 1.00397 1.00317 40000. 0.96089 0.98139 0.98534 42500. 0.93330 0.95889 0.96782 45000. 0.90579 0.93657 0.95068 47500. 0.87864 0.91456 0.93396 50000. 0.85216 0.89298 0.91771 52500. 0.82670 0.87203 0.90197 55000. 0.80261 0.85186 0.88681 57500. 0.78024 0.83267 0.87227 60000. 0.75989 0.81461 0.85841 62500. 0.74174 0.79783 0.84527 65000. 0.72588 0.78245 0.83288 67500. 0.71230 0.76852 0.82129 70000. 0.70085 0.75608 0.81051 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-7 Table B.6 [ J Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.328 1.307 1.299 100. 1.322 1.303 1.297 500. 1.314 1.299 1.293 1000. 1.305 1.294 1.288 1500. 1.294 1.289 1.283 2000. 1.286 1.283 1.278 2500. 1.277 1.277 1.273 3000. 1.270 1.272 1.268 3500. 1.264 1.266 1.263 4000. 1.258 1.261 1.258 4500. 1.253 1.255 1.253 5000. 1.247 1.249 1.249 5500. 1.241 1.243 1.244 6000. 1.234 1.237 1.238 6500. 1.228 1.231 1.233 7000. 1.221 1.225 1.228 7500. 1.215 1.219 1.223 8000. 1.208 1.213 1.218 8500. 1.201 1.207 1.213 9000. 1.194 1.200 1.208 9500. 1.187 1.194 1.202 10000. 1.183 1.188 1.197 10500. 1.179 1.182 1.192 11000. 1.176 1.175 1.187 11500. 1.172 1.169 1.181 12000. 1.169 1.162 1.176 12500. 1.165 1.156 1.171 13000. 1.162 1.149 1.166 13500. 1.158 1.143 1.160 14000. 1.154 1.136 1.155 14500. 1.150 1.129 1.150 15000. 1.146 1.124 1.145 15500. 1.142 1.122 1.139 16000. 1.138 1.119 1.134 16500. 1.133 1.117 1.130 17000. 1.130 1.115 1.125 17500. 1.126 1.113 1.121 18000. 1.123 1.111 1.117 18500. 1.120 1.109 1.113 19000. 1.117 1.107 1.110 19500. 1.115 1.105 1.108 20000. 1.112 1.104 1.105 20500. 1.110 1.102 1.103 21000. 1.108 1.101 1.101 21500. 1.105 1.099 1.100 22000. 1.103 1.098 1.098 22500. 1.101 1.097 1.097 23000. 1.100 1.096 1.096 25000. 1.095 1.090 1.093 27500. 1.092 1.087 1.092 30000. 1.089 1.086 1.091 32500. 1.086 1.084 1.091 35000. 1.085 1.083 1.089 37500. 1.086 1.081 1.088 40000. 1.086 1.079 1.087 42500. 1.086 1.077 1.086 45000. 1.083 1.075 1.085 47500. 1.079 1.072 1.084 50000. 1.077 1.070 1.082 52500. 1.072 1.067 1.081 55000. 1.065 1.065 1.079 57500. 1.057 1.062 1.077 60000. 1.047 1.059 1.075 62500. 1.044 1.057 1.074 65000. 1.050 1.054 1.072 67500. 1.058 1.057 1.073 70000. 1.065 1.061 1.074 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Desion Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-8 Table B.7 [ ] Hot Uncontrolled kI Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.06077 1.05090 1.03402 100. 1.03698 1.02866 1.01421 500. 1.03601 1.02853 1.01499 1000. 1.03947 1.03256 1.01939 1500. 1.04437 1.03786 1.02469 2000. 1.04967 1.04347 1.03015 2500. 1.05516 1.04914 1.03552 3000. 1.06089 1.05490 1.04080 3500. 1.06691 1.06082 1.04606 4000. 1.07324 1.06692 1.05135 4500. 1.07987 1.07322 1.05671 5000. 1.08681 1.07971 1.06215 5500. 1.09407 1.08642 1.06768 6000. 1.10166 1.09336 1.07330 6500. 1.10963 1.10054 1.07904 7000. 1.11799 1.10799 1.08491 7500. 1.12676 1.11572 1.09095 8000. 1.13596 1.12374 1.09714 8500. 1.14565 1.13206 1.10351 9000. 1.15584 1.14069 1.11003 9500. 1.16648 1.14962 1.11670 10000. 1.17738 1.15875 1.12348 10500. 1.18814 1.16787 1.13032 11000. 1.19827 1.17664 1.13706 11500. 1.20729 1.18466 1.14349 12000. 1.21479 1.19164 1.14938 12500. 1.22043 1.19739 1.15452 13000. 1.22405 1.20174 1.15882 13500. 1.22562 1.20455 1.16221 14000. 1.22528 1.20581 1.16466 14500. 1.22335 1.20563 1.16611 15000. 1.22026 1.20421 1.16656 15500. 1.21639 1.20177 1.16607 16000. 1.21166 1.19858 1.16478 16500. 1.20692 1.19486 1.16278 17000. 1.20219 1.19061 1.16022 17500. 1.19745 1.18636 1.15721 18000. 1.19252 1.18187 1.15385 18500. 1.18759 1.17738 1.15026 19000. 1.18265 1.17288 1.14650 20000. 1.17279 1.16390 1.13860 22500. 1.14784 1.14137 1.11873 25000. 1.12252 1.11885 1.09911 27500. 1.09679 1.09627 1.07978 30000. 1.07060 1.07364 1.06071 32500. 1.04395 1.05093 1.04189 35000. 1.01686 1.02814 1.02331 37500. 0.98940 1.00532 1.00500 40000. 0.96168 0.98252 0.98698 42500. 0.93386 0.95981 0.96930 45000. 0.90617 0.93731 0.95200 47500. 0.87888 0.91513 0.93514 50000. 0.85232 0.89344 0.91876 52500. 0.82684 0.87241 0.90293 55000. 0.80281 0.85221 0.88770 57500. 0.78057 0.83303 0.87311 60000. 0.76039 0.81504 0.85922 62500. 0.74245 0.79836 0.84608 65000. 0.72683 0.78312 0.83372 67500. 0.71349 0.76935 0.82218 70000. 0.70228 0.75710 0.81147 AREVA NP Inc.
Jontrolled Uocument Mh"rloIr FIl DcslpcAinn PRnnrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-9 Table B.8 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void Wd/MTEu History History History
- 0. 1.267 1.267 1.266 100. 1.268 1.265 1.265 500. 1.263 1.261 1.261 1000. 1.256 1.256 1.256 1500. 1.248 1.250 1.251 2000. 1. 240 1.244 1.246 2500. 1.237 1.239 1.240 3000. 1.234 1.233 1.235 3500. 1.231 1.227 1.230 4000. 1.228 1.221 1.225 4500. 1.224 1.215 1.220 5000. 1.221 1.209 1.215 5500. 1.217 1.203 1.209 6000. 1.213 1.197 1.204 6500. 1.209 1.190 1.199 7000. 1.205 1.184 1.193 7500. 1.200 1.178 1.188 8000. 1.196 1.171 1.183 8500. 1.191 1.165 1.177 9000. 1.186 1.158 1.172 9500. 1,181 1.152 1.167 10000. 1.176 1.146 1.161 10500. 1.171 1.140 1.156 11000. 1.165 1.135 1.151 11500. 1.160 1.132 1.146 12000. 1.154 1.128 1.141 12500. 1.149 1.125 1.137 13000. 1.144 1.122 1.133 13500. 1.140 1.119 1.129 14000. 1.137 1.116 1.126 14500. 1.133 1.114 1.123 15000. 1.130 1.112 1.120 15500. 1.128 1.110 1.118 16000. 1.125 1.108 1.116 16500. 1.123 1.107 1.114 17000. 1.121 1.105 1.112 17500. 1.118 1.104 1.111 18000. 1.116 1.103 1.109 18500. 1.113 1.101 1.108 19000. 1. 111 1.100 1.107 20000. 1.106 1.097 1.105 22500. 1.100 1.092 1.099 25000. 1.097 1.090 1.094 27500. 1.094 1.088 1.091 30000. 1.091 1.087 1.091 32500. 1.088 1.085 1.090 35000. 1.085 1.083 1.089 37500. 1.081 1.082 1.087 40000. 1.077 1.080 1.086 42500. 1.076 1.077 1.085 45000. 1.074 1.075 1.084 47500. 1.073 1.072 1.082 50000. 1.070 1.069 1.081 52500. 1.065 1.067 1.079 55000. 1.058 1.064 1.077 57500. 1.050 1.061 1.075 60000. 1.045 1.058 1.073 62500. 1.042 1.055 1.072 65000. 1.046 1.052 1.070 67500. 1.054 1.053 1.068 70000. 1.062 1.057 1.069 AREVA NP Inc.
Uontrolled uocument M, ir"lr ,i m1 flneinn Pmnnrf ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-10 Table B.9 ] Hot Uncontrolled k.
EXposure 0.00 Void 0.40 Void 0.80 Void MWd/DTU History History History
- 0. 1.08504 1.06587 1.04110 100. 1.06116 1.04379 1.02161 500. 1.05835 1.04189 1.02075 1000. 1.05892 1.04312 1.02259 1500. 1.06049 1.04515 1.02496 2000. 1.06232 1.04734 1.02735 2500. 1.06416 1.04950 1.02961 3000. 1.06597 1.05154 1.03170 3500. 1.06779 1.05352 1.03364 4000. 1.06967 1.05549 1.03550 4500. 1.07163 1.05748 1.03732 5000. 1.07370 1.05952 1.03911 5500. 1.07587 1.06163 1.04092 6000. 1.07817 1.06382 1.04274 6500. 1.08060 1.06609 1.04459 7000. 1.08314 1.06845 1.04649 7500. 1.08579 1.07088 1.04845 8000. 1.08856 1.07339 1.05047 8500. 1.09145 1.07598 1.05254 9000. 1.09446 1.07864 1.05465 9500. 1.09762 1.08140 1.05681 10000. 1.10092 1.08425 1.05901 10500. 1.10436 1.08720 1.06125 11000. 1.10795 1.09026 1.06353 11500. 1.11172 1.09343 1.06585 12000. 1.11568 1.09672 1.06822 12500. 1.11988 1.10014 1.07064 13000. 1.12436 1.10371 1.07313 13500. 1.12914 1.10747 1.07569 14000. 1.13420 1.11142 1.07833 14500. 1.13957 1.11554 1.08104 15000. 1.14515 1.11982 1.08384 15500. 1.15066 1.12414 1.08669 16000. 1.15573 1.12838 1.08956 16500. 1.16011 1.13226 1.09238 17000. 1.16354 1.13559 1.09503 17500. 1.16581 1.13822 1.09741 18000. 1.16679 1.14003 1.09938 18500. 1.16645 1.14094 1.10087 19000. 1.16491 1.14091 1.10181 19500. 1.16237 1.13996 1.10219 20000. 1.15908 1.13819 1.10199 20500. 1.15528 1.13574 1.10121 21000. 1.15114 1.13274 1.09989 21500. 1.14659 1.12937 1.09809 22000. 1.14204 1.12571 1.09588 22500. 1.13749 1.12187 1.09331 23000. 1.13286 1.11778 1.09047 23500. 1.12824 1.11368 1.08741 24000. 1.12361 1.10959 1.08420 24500. 1.11899 1.10549 1.08086 25000. 1.11436 1.10140 1.07745 25500. 1.10973 1.09732 1.07399 27500. 1.09122 1.08099 1.05985 30000. 1.06804 1.06077 1.04247 32500. 1.04483 1.04077 1.02546 35000. 1.02159 1.02101 1.00886 37500. 0.99838 1.00151 0.99268 40000. 0.97526 0.98228 0.97693 42500. 0.95230 0.96338 0.96164 45000. 0.92962 0.94485 0.94683 47500. 0.90735 0.92676 0.93252 50000. 0.88565 0.90917 0.91874 52500. 0.86468 0.89214 0.90550 55000. 0.84460 0.87577 0.89284 57500. 0.82559 0.86011 0.88075 60000. 0.80779 0.84525 0.86926 62500. 0.79135 0.83124 0.85838 65000. 0.77636 0.81813 0.84810 67500. 0.76285 0.80595 0.83844 70000. 0.75084 0.79473 0.82939 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-11 Table B.1O ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.334 1.332 1.317 100. 1.333 1.331 1.316 500. 1.330 1.327 1.313 1000. 1.325 1.323 1.309 1500. 1.321 1.318 1.305 2000. 1.316 1.313 1.301 2500. 1.311 1.308 1.296 3000. 1.306 1.304 1.292 3500. 1.302 1.299 1.288 4000. 1.297 1.294 1.284 4500. 1.292 1.290 1.280 5000. 1.287 1.285 1.276 5500. 1.282 1.280 1.272 6000. 1.277 1.275 1.268 6500. 1.272 1.271 1.264 7000. 1.267 1.266 1.260 7500. 1.262 1.261 1.256 8000. 1.256 1.256 1.252 8500. 1.251 1.251 1.248 9000. 1.245 1.246 1.244 9500. 1.240 1.241 1.240 10000. 1.234 1.236 1.235 10500. 1.228 1.231 1.231 11000. 1.222 1.226 1.227 11500. 1.216 1.221 1.223 12000. 1.210 1.215 1.218 12500. 1.204 1.210 1.214 13000. 1.198 1.205 1.210 13500. 1.192 1.200 1.206 14000. 1.186 1.194 1.201 14500. 1.180 1.189 1.197 15000. 1.173 1.184 1.193 15500. 1.167 1.178 1.188 16000. 1.161 1.173 1.184 16500. 1.155 1.168 1.180 17000. 1.150 1.163 1.176 17500. 1.145 1.158 1.172 18000. 1.141 1.154 1.168 18500. 1.137 1.150 1.164 19000. 1.134 1.146 1.161 19500. 1.131 1.143 1.157 20000. 1.129 1.140 1.154 20500. 1.126 1.137 1.151 21000. 1.124 1.135 1.149 21500. 1.122 1.132 1.146 22000. 1.119 1.130 1.144 22500. 1.117 1.128 1.142 23000. 1.115 1.126 1.140 23500. 1.113 1.124 1.138 24000. 1. 111 1.122 1.136 24500. 1.109 1.120 1.135 25000. 1.107 1.118 1.133 25500. 1.105 1.116 1.131 27500. 1.099 1.108 1.125 30000. 1.096 1.099 1.118 32500. 1.093 1.089 1.111 35000. 1.088 1.085 1.104 37500. 1.084 1.082 1.097 40000. 1.079 1,079 1.091 42500. 1.074 1.076 1.085 45000. 1.069 1.073 1.079 47500. 1.067 1.069 1.074 50000. 1.063 1.065 1.076 52500. 1.063 1.062 1.088 55000. 1. 060 1.058 1.100 57500. 1.056 1.055 1.113 60000. 1.050 1.054 1.125 62500. 1.052 1.072 1.138 65000. 1.073 1.089 1.150 67500. 1.093 1.105 1.163 70000. 1 . 111 1.121 1.174 AREVA NP Inc.
Uontrollea Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-12 Table B.11 ] Hot Uncontrolled ko Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.05951 1.04216 1.01931 100. 1.03678 1.02125 1.00102 500. 1.03484 1.02022 1.00109 1000. 1.03643 1.02246 1.00394 1500. 1.03899 1.02546 1.00727 2000. 1.04182 1.02862 1.01058 2500. 1.04468 1.03173 1.01373 3000. 1.04753 1.03476 1.01670 3500. 1.05043 1.03774 1.01954 4000. 1.05341 1.04072 1.02229 4500. 1.05652 1.04375 1.02500 5000. 1.05978 1.04686 1.02769 5500. 1.06319 1.05006 1.03039 6000. 1.06675 1.05336 1.03313 6500. 1.07046 1.05676 1.03591 7000. 1.07431 1.06025 1.03875 7500. 1.07833 1.06384 1.04166 8000. 1.08254 1.06752 1.04462 8500. 1.08694 1.07133 1.04764 9000. 1.09154 1.07528 1.05073 9500. 1.09635 1.07937 1.05387 10000. 1.10137 1.08361 1.05708 10500. 1.10663 1.08800 1.06035 11000. 1.11217 1.09255 1.06371 11500. 1.11805 1.09731 1.06714 12000. 1.12426 1.10227 1.07066 12500. 1.13081 1.10745 1.07428 13000. 1.13762 1.11282 1.07798 13500. 1.14454 1.11832 1.08177 14000. 1.15129 1.12382 1.08561 14500. 1.15751 1.12913 1.08946 15000. 1.16291 1.13401 1.09322 15500. 1.16731 1.13827 1.09677 16000. 1.17054 1.14177 1.09998 16500. 1.17250 1.14444 1.10274 11000. 1.17316 1.14620 1.10497 17500. 1.17261 1.14701 1.10662 18000. 1.17104 1.14687 1.10768 18500. 1.16867 1.14587 1.10812 19000. 1.16569 1.14413 1.10795 19500. 1.16225 1.14179 1.10718 20000. 1.15845 1.13898 1.10586 20500. 1.15439 1.13582 1.10406 21000. 1.15013 1.13236 1.10186 21500. 1.14572 1.12871 1.09932 22000. 1.14111 1.12489 1.09652 22500. 1.13650 1.12097 1.09351 23000. 1.13186 1.11697 1.09033 23500. 1.12723 1.11292 1.08703 24000. 1.12259 1.10877 1.08365 24500. 1.11796 1.10461 1.08020 25000. 1.11332 1.10046 1.07671 25500. 1.10870 1.09637 1.07319 26000. 1.10408 1.09229 1.06967 27500. 1.09021 1.08003 1.05899 30000. 1.06706 1.05985 1.04162 32500. 1.04387 1.03989 1.02464 35000. 1.02066 1.02016 1.00807 37500. 0.99747 1.00068 0.99192 40000. 0.97437 0.98149 0.97620 42500. 0.95144 0.96261 0.96093 45000. 0.92880 0.94411 0.94614 47500. 0.90657 0.92605 0.93186 50000. 0.88490 0.90848 0.91810 52500. 0.86398 0.89149 0.90489 55000. 0.84395 0.87515 0.89225 57500. 0.82499 0.85952 0.88019 60000. 0.80724 0.84470 0.86872 62500. 0.79085 0.83072 0.85786 65000. 0.77590 0.81764 0.84760 67500. 0.76244 0.80549 0.83796 70000. 0.75047 0.79430 0.82892 AREVA NP Inc.
Gontrolled uocument NrIlmlr Pil In"1c inn RPnnrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-13 Table B.12 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History 1.343 1.323
- 0. 1.348 1.342 1.322 100. 1.347 1.338 1.319 500. 1.343 1.333 1.314 1000. 1.338 1500. 1.333 1.327 1.310 2000. 1.327 1.322 1.305 2500. 1.322 1.317 1.301 3000. 1.316 1.311 1.296 3500. 1.311 1.306 1.292 4000. 1.305 1.301 1.288 4500. 1.300 1.295 1.283 5000. 1.294 1.290 1.279 5500. 1.288 1.285 1.274 6000. 1.282 1.279 1.270 6500. 1.276 1.273 1.265 7000. 1.270 1.268 1.261 7500. 1.264 1.262 1.256 8000. 1.257 1.257 1.252 8500. 1.251 1.251 1.247 9000. 1.244 1.245 1.243 9500. 1.238 1.239 1.238 10000. 1.231 1.234 1.233 10500. 1.224 1.228 1.229 11000. 1.217 1.222 1.224 11500. 1.210 1.216 1.219 12000. 1.203 1.210 1.215 12500. 1.196 1.204 1.210 13000. 1.189 1.198 1.205 13500. 1.182 1.192 1.200 14000. 1.175 1.187 1.196 14500. 1.169 1.181 1.191 15000. 1.163 1.175 1.187 15500. 1.158 1.170 1.182 16000. 1.153 1.165 1.178 16500. 1.149 1.161 1.174 17000. 1.145 1.157 1.170 17500. 1.142 1.153 1.166 18000. 1.139 1.150 1.163 18500. 1.136 1.147 1.160 19000. 1.134 1.144 1.157 19500. 1.131 1.142 1.154 20000. 1.129 1.139 1.152 20500. 1.127 1.137 1.150 21000. 1.125 1.135 1.148 21500. 1.122 1.133 1.146 22000. 1.120 1.131 1.144 22500. 1.118 1.129 1.142 23000. 1.116 1.127 1.141 23500. 1.114 1.125 1.139 24000. 1.111 1.123 1.137 24500. 1.109 1.121 1.136 25000. 1.107 1.119 1.134 25500. 1.105 1.117 1.133 26000. 1.103 1.115 1.131 27500. 1.096 1.109 1.127 30000. 1.092 1.100 1.120 32500. 1.089 1.090 1.112 35000. 1.085 1.082 1.105 37500. 1.080 1.079 1.098 40000. 1.075 1.076 1.092 42500. 1.072 1.073 1.086 45000. 1.070 1.070 1.080 47500. 1.069 1.068 1.078 50000. 1.070 1.066 1.077 52500. 1.069 1.063 1.089 55000. 1.066 1.060 1.101 57500. 1.061 1.057 1.113 60000. 1.055 1.055 1.126 62500. 1.052 1.072 1.139 65000. 1.074 1.089 1.151 67500. 1.093 1.106 1.163 70000. 1.112 1.121 1.175 AREVA NP Inc.
Gontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page B-14 Table B.13 [ ] Hot Uncontrolled k.
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.04451 1.03218 1.01204 100. 1.02073 1.00999 0.99235 500. 1.01835 1.00852 0.99200 1000. 1.01965 1.01055 0.99473 1500. 1.02220 1.01365 0.99823 2000. 1.02513 1.01703 1.00188 2500. 1.02813 1.02044 1.00544 3000. 1.03121 1.02381 1.00885 3500. 1.03442 1.02721 1.01217 4000. 1.03779 1.03069 1.01545 4500. 1.04135 1.03428 1.01874 5000. 1.04510 1.03799 1.02206 5500. 1.04905 1.04185 1.02542 6000. 1.05320 1.04586 1.02885 6500. 1.05753 1.05000 1.03234 7000. 1.06206 1.05428 1.03593 7500. 1.06676 1.05869 1.03960 8000. 1.07166 1.06322 1.04335 8500. 1.07676 1.06789 1.04719 9000. 1.08207 1.07269 1.05111 9500. 1.08761 1.07766 1.05510 10000. 1.09338 1.08279 1.05918 10500. 1.09942 1.08811 1.06334 11000. 1.10577 1.09362 1.06760 11500. 1.11248 1.09935 1.07194 12000. 1.11961 1.10535 1.07640 12500. 1.12722 1.11164 1.08098 13000. 1.13536 1.11828 1.08571 13500. 1.14390 1.12527 1.09061 14000. 1.15257 1.13256 1.09568 14500. 1.16107 1.13998 1.10091 15000. 1.16903 1.14723 1.10626 15500. 1.17590 1.15397 1.11161 16000. 1.18125 1.15983 1.11676 16500. 1.18491 1.16454 1.12146 17000. 1.18686 1.16788 1.12549 17500. 1.18714 1.16979 1.12872 18000. 1.18588 1.17026 1.13106 18500. 1.18333 1.16942 1.13246 19000. 1.17986 1.16746 1.13291 19500. 1.17544 1.16463 1.13242 20000. 1.17102 1.16120 1.13110 20500. 1.16611 1.15735 1.12907 21000. 1.16120 1.15297 1.12647 21500. 1.15628 1.14859 1.12345 22000. 1.15137 1.14421 1.12013 22500. 1.14646 1.13983 1.11661 25000. 1.12134 1.11752 1.09751 27500. 1.09581 1.09513 1.07838 30000. 1.06985 1.07268 1.05945 32500. 1.04343 1.05016 1.04077 35000. 1.01657 1.02758 1.02234 37500. 0.98934 1.00495 1.00418 40000. 0.96183 0.98233 0.98630 42500. 0.93421 0.95979 0.96874 45000. 0.90667 0.93743 0.95156 47500. 0.87949 0.91538 0.93480 50000. 0.85298 0.89377 0.91851 52500. 0.82750 0.87279 0.90274 55000. 0.80338 0.85260 0.88755 57500. 0.78100 0.83338 0.87298 60000. 0.76063 0.81531 0.85909 62500. 0.74246 0.79851 0.84593 65000. 0.72659 0.78311 0.83352 67500. 0.71299 0.76918 0.82192 70000. 0.70153 0.75673 0.81113 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Desion Reoort ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-15 Table B.14 [ ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void tlWd/MTUi History History History
- 0. 1.282 1.272 1.272 100. 1.277 1.271 1.271 500. 1.274 1.268 1.268 1000. 1.268 1.264 1.264 1500. 1.262 1.259 1.260 2000. 1.255 1.254 1.255 2500. 1.247 1.249 1.251 3000. 1.239 1.245 1.247 3500. 1.235 1.240 1.242 4000. 1.232 1.235 1.238 4500. 1.230 1.230 1.234 5000. 1.227 1.225 1.230 5500. 1.224 1.220 1.225 6000. 1.221 1.215 1.221 6500. 1.218 1.210 1.216 7000. 1.214 1.205 1.212 7500. 1.211 1.200 1.207 8000. 1.207 1.195 1.203 8500. 1.204 1.189 1.198 9000. 1.200 1.184 1.194 9500. 1.196 1.179 1.189 10000. 1.192 1.173 1.185 10500. 1.187 1.168 1.180 11000. 1.183 1.162 1.175 11500. 1.179 1.157 1.171 12000. 1.175 1.152 1.166 12500. 1.170 1.146 1.162 13000. 1.166 1.140 1.157 13500. 1.161 1.135 1.152 14000. 1.156 1.131 1.148 14500. 1.151 1.128 1.143 15000. 1.146 1.124 1.139 15500. 1.140 1.121 1.134 16000. 1.135 1.118 1.130 16500. 1.130 1.114 1.126 17000. 1.125 1.111 1.122 17500. 1.121 1.108 1.119 18000. 1.117 1.106 1.115 18500. 1.115 1.103 1.112 19000. 1.114 1.101 1.110 19500. 1.113 1.099 1.108 20000. 1.112 1.098 1.106 20500. 1.111 1.096 1.104 21000. 1.110 1. 095 1.102 21500. 1.110 1.093 1.101 22000. 1.109 1.092 1.100 22500. 1.108 1.091 1.099 25000. 1.104 1.089 1.093 27500. 1.100 1.088 1.092 30000. 1.095 1.086 1.091 32500. 1.090 1.085 1.091 35000. 1.085 1.083 1.090 37500. 1.082 1.081 1.088 40000. 1.082 1.080 1.087 42500. 1.081 1.078 1.086 45000. 1.080 1.075 1.085 47500. 1.079 1.073 1.084 50000. 1.077 1.070 1.082 52500. 1.072 1.068 1.081 55000. 1.065 1.065 1.079 57500. 1.057 1.062 1.077 60000. 1.047 1.059 1.075 62500. 1.044 1.057 1.074 65000. 1.048 1.054 1.072 67500. 1.056 1.055 1.070 70000. 1.063 1.059 1.072 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-16 Table B.15 [ ] Hot Uncontrolled k.
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.06140 1.05150 1.03458 100. 1.03759 1.02925 1.01475 500. 1.03661 1.02910 1.01552 1000. 1.04004 1.03311 1.01989 1500. 1.04493 1.03838 1.02517 2000. 1.05021 1.04397 1.03061 2500. 1.05567 1.04962 1.03596 3000. 1.06138 1.05536 1.04122 3500. 1.06737 1.06125 1.04646 4000. 1.07367 1.06732 1.05173 4500. 1. 08027 1.07359 1.05706 5000. 1.08719 1.08007 1.06248 5500. 1.09442 1.08675 1.06798 6000. 1.10198 1.09365 1.07358 6500. 1.10991 1.10080 1.07930 7000. 1.11824 1. 10822 1.08515 7500. 1.12696 1. 11592 1.09115 8000. 1.13613 1.12390 1.09733 8500. 1.14577 1.13218 1.10366 9000. 1.15592 1.14078 1.11016 9500. 1.16652 1.14967 1.11680 10000. 1.17740 1.15877 1.12356 10500. 1.18816 1.16788 1.13037 11000. 1.19830 1.17665 1.13709 11500. 1.20735 1.18468 1.14352 12000. 1.21490 1.19169 1.14941 12500. 1.22061 1.19748 1.15457 13000. 1.22430 1.20188 1.15888 13500. 1.22592 1.20473 1.16230 14000. 1.22564 1.20604 1.16477 14500. 1.22375 1.20591 1.16625 15000. 1.22069 1.20453 1.16673 15500. 1.21685 1.20212 1.16629 16000. 1.21213 1.19895 1.16502 16500. 1.20740 1.19525 1.16306 17000. 1.20267 1.19102 1.16052 17500. 1.19795 1.18678 1.15752 18000. 1.19303 1.18229 1.15418 18500. 1.18810 1.17780 1.15060 19000. 1.18318 1.17332 1.14686 20000. 1.17333 1.16434 1.13897 22500. 1.14841 1.14184 1.11910 25000. 1.12312 1.11934 1.09950 27500. 1.09741 1.09679 1.08018 30000. 1.07126 1.07417 1.06112 32500. 1.04464 1.05148 1.04231 35000. 1.01758 1.02871 1.02374 37500. 0.99014 1.00591 1.00544 40000. 0.96244 0.98312 0.98742 42500. 0.93463 0.96042 0.96974 45000. 0.90694 0.93792 0.95244 47500. 0.87965 0.91575 0.93558 50000. 0.85307 0.89405 0.91920 52500. 0.82755 0.87300 0.90336 55000. 0.80347 0.85278 0.88812 57500. 0.78117 0.83358 0.87352 60000. 0.76092 0.81555 0.85962 62500. 0.74291 0.79883 0.84645 65000. 0.72722 0.78353 0.83408 67500. 0.71381 0.76972 0.82252 70000. 0.70253 0.75742 0.81178 AREVA NP Inc.
Gontrolledi Uccument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-17 Table B.16 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History 1.266 1.265
- 0. 1.265 1.264 1.264 100. 1.267 500. 1.262 1.260 1.260 1000. 1.256 1.255 1.255 1500. 1.247 1.249 1.250 2000. 1.238 1.244 1.245 2500. 1.234 1.238 1.240 3000. 1.231 1.232 1.235 3500. 1.228 1.226 1.230 4000. 1.225 1.220 1.224 4500. 1.222 1.214 1.219 5000. 1.218 1.208 1.214 5500. 1.214 1.202 1.209 6000. 1.211 1.196 1.203 6500. 1.206 1.190 1.198 1.183 1.193 7000. 1.202 1.177 1.188 7500. 1.198 1.171 1.182 8000. 1.193 8500. 1.189 1.164 1.177 9000. 1.184 1.158 1.172 9500. 1.179 1.152 1.166 10000. 1.174 1.146 1.161 10500. 1.169 1.140 1.156 11000. 1.163 1.134 1.151 11500. 1.158 1.130 1.146 12000. 1.152 1.126 1.141 12500. 1.147 1.123 1.137 13000. 1.143 1.120 1.133 13500. 1.139 1.117 1.129 14000. 1.135 1.115 1.125 14500. 1.132 1.113 1.122 15000. 1.129 1.110 1.120 15500. 1.126 1.109 1.117 16000. 1.124 1.107 1.115 16500. 1.121 1.105 1.113 17000. 1.118 1.104 1.112 17500. 1.116 1.102 1.110 18000. 1.115 1.101 1.109 18500. 1.114 1.099 1.107 19000. 1.113 1.098 1.106 20000. 1.111 1.095 1.104 22500. 1.108 1.091 1.099 25000. 1.104 1.089 1.093 27500. 1.100 1.088 1.091 30000. 1.095 1.086 1.090 32500. 1.090 1.084 1.089 35000. 1.084 1.083 1.088 37500. 1.080 1.081 1.087 40000. 1.077 1.079 1.086 42500. 1.075 1.077 1.084 45000. 1.074 1.074 1.083 47500. 1.072 1.072 1.082 50000. 1.069 1.069 1.080 52500. 1.065 1.066 1.078 55000. 1.058 1.063 1.077 57500. 1.050 1.060 1.075 60000. 1.045 1.057 1.073 62500. 1.042 1.055 1.071 65000. 1.046 1.052 1.069 67500. 1.054 1.053 1.068 70000. 1.062 1.057 1.069 AREVA NP Inc.
(Jontrolled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-18 Table B.17 [ ] Hot Uncontrolled k.
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.10755 1.08726 1. 06087 100. 1.08273 1.06427 1.04051 500. 1.07950 1.06192 1.03919 1000. 1.07965 1.06271 1.04056 1500. 1.08083 1.06435 1.04253 2000. 1.08227 1.06616 1.04453 2500. 1.08371 1.06792 1.04641 3000. 1.08511 1.06957 1.04812 3500. 1.08651 1.07115 1.04968 4000. 1.08796 1.07270 1.05116 4500. 1.08947 1.07428 1.05259 5000. 1.09107 1.07589 1.05401 5500. 1.09277 1.07756 1.05543 6000. 1.09457 1.07931 1.05687 6500. 1.09649 1.08112 1.05834 7000. 1.09851 1.08302 1.05986 7500. 1.10064 1.08500 1.06144 8000. 1.10289 1.08704 1.06307 8500. 1.10525 1.08917 1.06476 9000. 1.10773 1.09137 1.06649 9500. 1.11034 1.09365 1.06828 10000. 1.11308 1.09603 1.07010 10500. 1.11596 1.09851 1.07197 11000. 1.11899 1.10108 1.07387 11500. 1.12217 1.10377 1.07582 12000. 1.12555 1.10657 1.07781 12500. 1.12915 1.10950 1.07986 13000. 1.13301 1.11258 1.08198 13500. 1.13714 1.11583 1.08416 14000. 1.14154 1.11925 1.08643 14500. 1.14621 1.12284 1.08877 15000. 1.15105 1.12657 1.09118 15500. 1.15584 1.13035 1.09365 16000. 1.16023 1.13401 1.09613 16500. 1.16393 1.13730 1.09854 17000. 1.16672 1.14004 1.10076 17500. 1.16842 1.14210 1.10267 18000. 1.16893 1.14336 1.10417 18500. 1.16822 1.14377 1.10518 19000. 1.16639 1.14330 1.10566 19500. 1.16364 1.14198 1.10558 20000. 1.16019 1.13989 1.10495 20500. 1.15627 1.13718 1.10378 21000. 1.15176 1.13400 1.10211 21500. 1.14725 1.13046 1.10000 22000. 1.14275 1.12669 1.09752 22500. 1.13824 1.12271 1.09474 23000. 1.13361 1.11860 1.09172 23500. 1.12898 1.11448 1.08852 24000. 1.12435 1.11037 1.08519 24500. 1.11972 1.10625 1.08177 25000. 1.11509 1.10214 1.07829 27500. 1.09188 1.08166 1.06057 30000. 1.06864 1.06138 1.04312 32500. 1.04536 1.04134 1.02606 35000. 1.02205 1.02152 1.00941 37500. 0.99877 1.00196 0.99319 40000. 0.97558 0.98268 0.97740 42500. 0.95256 0.96373 0.96207 45000. 0.92983 0.94515 0.94722 47500. 0.90750 0.92702 0.93288 50000. 0.88576 0.90939 0.91908 52500. 0.86475 0.89233 0.90582 55000. 0.84466 0.87593 0.89313 57500. 0.82564 0.86026 0.88103 60000. 0.80785 0.84539 0.86953 62500. 0.79143 0.83138 0.85864 65000. 0.77646 0.81827 0.84836 67500. 0.76299 0.80611 0.83870 70000. 0.75102 0.79491 0.82965 AREVA NP Inc.
(Jontroiieci Locument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM 1OXM Fuel M
T Page B-19 Table B.18 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.312 1.312 1.301 100. 1.312 1.312 1.301 500. 1.309 1.309 1.298 1000. 1.305 1.305 1.294 1500. 1.301 1.300 1.291 2000. 1.296 1.296 1.287 2500. 1.292 1.292 1.283 3000. 1.288 1.288 1.280 3500. 1.284 1.283 1.276 4000. 1.280 1.279 1.272 4500. 1.276 1.275 1.269 5000. 1.271 1.271 1.265 5500. 1.267 1.267 1.262 6000. 1.263 1.263 1.258 6500. 1.258 1.258 1.254 7000. 1.254 1.254 1.251 7500. 1.249 1.250 1.247 8000. 1.244 1.245 1.243 8500. 1.240 1.241 1.240 9000. 1.235 1.236 1.236 9500. 1.230 1.232 1.232 10000. 1.225 1.227 1.228 10500. 1.220 1.223 1.224 11000. 1.214 1.218 1.220 11500. 1.209 1.214 1.217 12000. 1.204 1.209 1.213 12500. 1.199 1.204 1.209 13000. 1.193 1.200 1.205 13500. 1.188 1.195 1.201 14000. 1.182 1.190 1.197 14500. 1.176 1.185 1.193 15000. 1.171 1.181 1.189 15500. 1.165 1.176 1.185 16000. 1.160 1.171 1.181 16500. 1.155 1.166 1.177 17000. 1.150 1.162 1.174 17500. 1.146 1.158 1.170 18000. 1.142 1.154 1.166 18500. 1.139 1.150 1.163 19000. 1.136 1.147 1.160 19500. 1.133 1.144 1.157 20000. 1.131 1.141 1.154 20500. 1.128 1.138 1.151 21000. 1.126 1.136 1.149 21500. 1.124 1.134 1.146 22000. 1.122 1.132 1.144 22500. 1.120 1.130 1.142 23000. 1.118 1.128 1.141 23500. 1.116 1.126 1.139 24000. 1.113 1.124 1.137 24500. 1.111 1.122 1.136 25000. 1.109 1.120 1.134 27500. 1.098 1.110 1.126 30000. 1.090 1.100 1.119 32500. 1.089 1.091 1.112 35000. 1.088 1.081 1.104 37500. 1.086 1.075 1.098 40000. 1.084 1.073 1.091 42500. 1.081 1.071 1.085 45000. 1.077 1.069 1.080 47500. 1.073 1.067 1.074 50000. 1.068 1.064 1.076 52500. 1.063 1.061 1.088 55000. 1.060 1.058 1.100 57500. 1.055 1.054 1.113 60000. 1.049 1.055 1.126 62500. 1.052 1.072 1.138 65000. 1.073 1.089 1.150 67500. 1.093 1.105 1.163 70000. 1. 111 1.121 1.174 AREVA NP Inc.
Controlled Uocument Nuclear Fuel Desion Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page 6-20 Table B.19 [ J Hot Uncontrolled ko Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.08123 1.06260 1.03797 100. 1.05758 1.04080 1.01885 500. 1.05518 1.03932 1.01844 1000. 1.05631 1.04109 1.02083 1500. 1.05844 1.04367 1.02374 2000. 1.06082 1.04641 1.02665 2500. 1.06322 1.04909 1.02940 3000. 1.06561 1.05167 1.03198 3500. 1.06803 1.05420 1.03441 4000. 1.07051 1.05673 1.03676 4500. 1.07310 1.05930 1.03907 5000. 1.07581 1.06193 1.04135 5500. 1.07866 1.06464 1.04365 6000. 1.08166 1.06745 1.04598 6500. 1.08479 1.07034 1.04835 7000. 1.08807 1.07333 1.05079 7500. 1.09150 1.07641 1.05329 8000. 1.09511 1.07960 1.05585 8500. 1.09890 1.08290 1.05847 9000. 1.10288 1.08633 1.06116 9500. 1.10705 1.08990 1.06391 10000. 1.11143 1.09361 1.06672 10500. 1.11604 1.09747 1.06960 11000. 1.12092 1.10149 1.07256 11500. 1.12611 1.10570 1.07559 12000. 1.13161 1.11011 1.07872 12500. 1.13741 1.11473 1.08193 13000. 1.14346 1.11951 1.08524 13500. 1.14962 1.12441 1.08862 14000. 1.15561 1.12930 1.09204 14500. 1.16110 1.13401 1.09546 15000. 1.16583 1.13830 1.09878 15500. 1.16965 1.14198 1.10187 16000. 1.17239 1.14493 1.10461 16500. 1.17397 1.14711 1.10689 17000. 1.17434 1.14842 1.10866 17500. 1.17358 1.14886 1.10988 18000. 1.17188 1.14842 1.11053 18500. 1.16943 1.14718 1.11059 19000. 1.16641 1.14525 1.11009 19500. 1.16295 1.14277 1.10902 20000. 1.15914 1.13986 1.10745 20500. 1.15508 1.13663 1.10544 21000. 1.15082 1.13314 1.10307 21500. 1.14642 1.12945 1.10039 22000. 1.14192 1.12562 1.09748 22500. 1.13728 1.12167 1.09439 23000. 1.13262 1.11766 1.09115 23500. 1.12795 1.11360 1.08780 24000. 1.12329 1.10944 1.08438 24500. 1.11862 1.10528 1.08090 25000. 1.11396 1.10112 1.07738 25500. 1.10933 1.09702 1.07385 26000. 1.10469 1.09293 1.07031 27500. 1.09079 1.08064 1.05960 30000. 1.06758 1.06041 1.04219 32500. 1.04433 1.04040 1.02517 35000. 1.02106 1.02062 1.00856 37500. 0.99781 1.00110 0.99237 40000. 0.97466 0.98185 0.97662 42500. 0.95168 0.96293 0.96132 45000. 0.92898 0.94439 0.94650 47500. 0.90670 0.92629 0.93219 50000. 0.88501 0.90869 0.91841 52500. 0.86405 0.89167 0.90518 55000. 0.84400 0.87530 0.89252 57500. 0.82504 0.85967 0.88044 60000. 0.80730 0.84483 0.86896 62500. 0.79092 0.83085 0.85810 65000. 0.77600 0.81777 0.84784 67500. 0.76257 0.80564 0.83820 70000. 0.75063 0.79446 0.82916 AREVA NP Inc.
Uontrolled Luocument ANP-3139(NP)
Nuclear Fuel Design Report Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-21 Table B.20 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.326 1.324 1.308 100. 1.325 1.323 1.307 500. 1.322 1.319 1.304 1000. 1.318 1.315 1.300 1500. 1.313 1.310 1.296 2000. 1.308 1.305 1.292 2500. 1.303 1.301 1.288 3000. 1.298 1.296 1.284 3500. 1.294 1.291 1.280 4000. 1.289 1.286 1.276 4500. 1.284 1.282 1.272 5000. 1.279 1.277 1.268 5500. 1.274 1.272 1.264 6000. 1.269 1.267 1.260 6500. 1.263 1.262 1.256 7000. 1.258 1.257 1.252 7500. 1.252 1.252 1.248 8000. 1.247 1.247 1.244 8500. 1.241 1.242 1.240 9000. 1.235 1.237 1.235 9500. 1.230 1.232 1.231 10000. 1.224 1.227 1.227 10500. 1.217 1.221 1.223 11000. 1.211 1.216 1.219 11500. 1.205 1.211 1.214 12000. 1.199 1.206 1.210 12500. 1.192 1.200 1.206 13000. 1.186 1.195 1.201 13500. 1.180 1.189 1.197 14000. 1.174 1.184 1.193 14500. 1.168 1.179 1.188 15000. 1.163 1.174 1.184 15500. 1.158 1.169 1.180 16000. 1.153 1.165 1.176 16500. 1.150 1.161 1.172 17000. 1.146 1.157 1.169 17500. 1.143 1.154 1.166 18000. 1.141 1.151 1.162 18500. 1.138 1.148 1.160 19000. 1.136 1.145 1.157 19500. 1.133 1.143 1.155 20000. 1.131 1.141 1.152 20500. 1.129 1.138 1.150 21000. 1.126 1.136 1.148 21500. 1.124 1.134 1.146 22000. 1.122 1.132 1.145 22500. 1.120 1.130 1.143 23000. 1.118 1.128 1.141 23500. 1.116 1.126 1.140 24000. 1.113 1.124 1.138 24500. 1.111 1.122 1.137 25000. 1.109 1.120 1.135 25500. 1.107 1.118 1.134 26000. 1.105 1.116 1.132 27500. 1.098 1. 111 1.128 30000. 1.087 1.101 1.120 32500. 1.084 1.091 1.113 35000. 1.083 1.082 1.106 37500. 1.081 1.076 1.099 40000. 1.079 1.074 1.092 42500. 1.076 1.073 1.086 45000. 1.072 1.071 1.081 47500. 1.069 1.068 1.078 50000. 1.070 1.066 1.077 52500. 1A069 1.063 1.089 55000. 1.066 1.060 1.101 57500. 1.061 1.057 1.113 60000. 1.054 1.055 1.126 62500. 1.053 1.073 1.139 65000. 1.074 1.089 1.151 67500. 1.094 1.106 1.163 70000. 1.112 1.121 1.175 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-22 Table B.21 [ ] Hot Uncontrolled k.
Exposure 0.00 Void 0.40 Void 0.80 Void WAd/MTU History History History
- 0. 1.06794 1.05501 1.03416 100. 1.04315 1.03183 1.01348 500. 1.04037 1.02993 1.01267 1000. 1.04128 1.03154 1.01494 1500. 1.04349 1.03428 1.01804 2000. 1.04606 1.03731 1.02129 2500. 1.04870 1.04034 1.02446 3000. 1.05140 1.04334 1.02748 3500. 1.05423 1.04636 1.03041 4000. 1.05719 1.04944 1.03329 4500. 1.06031 1.05261 1.03617 5000. 1.06360 1.05590 1.03907 5500. 1.06708 1.05931 1.04202 6000. 1.07075 1.06287 1.04501 6500. 1.07461 1.06656 1.04808 7000. 1.07865 1.07039 1.05123 7500. 1.08287 1.07434 1.05447 8000. 1.08728 1.07842 1.05780 8500. 1.09188 1.08263 1.06121 9000. 1.09670 1.08697 1.06470 9500. 1.10174 1.09147 1.06827 10000. 1.10704 1.09614 1.07191 10500. 1.11259 1.10100 1.07565 11000. 1.11844 1.10605 1.07947 11500. 1.12465 1.11133 1.08339 12000. 1.13128 1.11686 1.08742 12500. 1.13841 1.12268 1.09158 13000. 1.14605 1.12885 1.09588 13500. 1.15404 1.13537 1.10035 14000. 1.16207 1.14215 1.10497 14500. 1.16988 1.14903 1.10976 15000. 1.17696 1.15563 1.11464 15500. 1.18279 1.16162 1.11951 16000. 1.18702 1.16664 1.12412 16500. 1.18960 1.17043 1.12823 17000. 1.19055 1.17285 1.13161 17500. 1.18996 1.17386 1.13415 18000. 1.18800 1.17351 1.13582 18500. 1.18496 1.17196 1.13657 19000. 1.18116 1.16944 1.13640 19500. 1.17658 1.16621 1.13535 20000. 1.17201 1.16249 1.13353 20500. 1.16706 1.15812 1.13108 21000. 1.16211 1.15375 1.12814 21500. 1.15716 1.14939 1.12487 22500. 1.14726 1.14065 1.11755 25000. 1.12207 1.11830 1.09835 27500. 1.09648 1.09585 1.07914 30000. 1.07044 1.07333 1.06015 32500. 1.04395 1.05075 1.04142 35000. 1.01701 1.02809 1.02294 37500. 0.98969 1.00539 1.00473 40000. 0.96211 0.98270 0.98680 42500. 0.93440 0.96010 0.96919 45000. 0.90680 0.93768 0.95197 47500. 0.87956 0.91557 0.93516 50000. 0.85301 0.89392 0.91884 52500. 0.82749 0.87290 0.90304 55000. 0.80338 0.85269 0.88782 57500. 0.78101 0.83346 0.87323 60000. 0.76067 0.81539 0.85933 62500. 0.74255 0.79861 0.84616 65000. 0.72673 0.78324 0.83376 67500. 0.71319 0.76934 0.82216 70000. 0.70179 0.75693 0.81138 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM 1OXM Fuel M
T Page B-23 Table B.22 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void M*d/MTIU History History History
- 0. 1.260 1.253 1.255 100. 1.262 1.252 1.254 500. 1.259 1.249 1.251 1000. 1.254 1.245 1.248 1500. 1.250 1.241 1.244 2000. 1.248 1.237 1.240 2500. 1.245 1.232 1.236 3000. 1.243 1.228 1.232 3500. 1.240 1.224 1.229 4000. 1.237 1.220 1.225 4500. 1.234 1.215 1.221 5000. 1.231 1.211 1.217 5500. 1.228 1.207 1.213 6000. 1.225 1.202 1.209 6500. 1.221 1.198 1.205 7000. 1.217 1. 193 1.201 7500. 1.214 1.188 1.197 8000. 1.210 1.184 1.193 8500. 1.206 1.179 1.189 9000. 1.202 1.174 1.185 9500. 1.197 1.169 1.181 10000. 1.193 1.164 1.177 10500. 1.189 1.159 1.173 11000. 1.184 1.155 1.169 11500. 1.180 1.150 1.164 12000. 1.175 1.145 1.160 12500. 1.171 1.140 1.156 13000. 1.166 1.137 1.152 13500. 1.162 1.134 1.147 14000. 1.157 1.131 1.143 14500. 1.151 1.128 1.139 15000. 1.146 1.125 1.135 15500. 1.140 1.121 1.131 16000. 1.135 1.118 1.127 16500. 1.129 1.114 1.123 17000. 1.124 1.111 1.120 17500. 1.119 1.107 1.117 18000. 1.115 1.104 1.114 18500. 1.112 1.102 1.111 19000. 1.109 1.100 1.109 19500. 1.106 1.098 1.107 20000. 1.103 1.096 1.106 20500. 1.102 1.095 1.104 21000. 1.101 1.094 1.103 21500. 1.101 1.093 1.102 22500. 1.099 1.091 1.100 25000. 1.096 1.090 1.094 27500. 1.094 1.088 1.092 30000. 1.091 1.087 1.091 32500. 1.088 1.085 1.090 35000. 1.085 1.084 1.089 37500. 1.084 1.082 1.088 40000. 1.081 1.080 1.087 42500. 1.077 1.078 1.086 45000. 1.077 1.076 1.085 47500. 1.076 1.073 1.083 50000. 1.073 1.070 1.082 52500. 1.068 1.068 1.080 55000. 1.061 1.065 1.079 57500. 1.054 1.062 1.077 60000. 1.047 1.059 1.075 62500. 1.043 1.057 1.073 65000. 1.047 1.054 1.072 67500. 1.055 1.054 1.070 70000. 1.063 1.059 1.071 AREVA NP Inc.
Gontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page B-24 Table B.23 [ J Hot Uncontrolled k,.
Exposure 0.00 Void 0.40 Void 0.80 Void MWd/MTU History History History
- 0. 1.10951 1.09804 1.07822 100. 1.08364 1.07371 1.05637 500. 1.08162 1.07249 1.05603 1000. 1.08393 1.07535 1.05924 1500. 1.08770 1.07952 1.06344 2000. 1.09181 1.08395 1.06779 2500. 1.09607 1.08843 1.07203 3000. 1.10053 1.09296 1.07617 3500. 1.10523 1.09762 1.08027 4000. 1.11019 1.10243 1.08440 4500. 1.11538 1.10740 1.08858 5000. 1.12082 1.11251 1.09281 5500. 1.12651 1.11779 1.09712 6000. 1.13247 1.12325 1.10149 6500. 1.13873 1.12891 1.10596 7000. 1.14530 1.13479 1.11054 7500. 1.15219 1.14089 1.11526 8000. 1.15942 1.14720 1.12011 8500. 1.16703 1.15375 1.12509 9000. 1.17500 1.16054 1.13020 9500. 1.18329 1.16753 1.13542 10000. 1.19171 1.17464 1.14073 10500. 1.19998 1.18170 1.14604 11000. 1.20778 1.18843 1.15123 11500. 1.21474 1.19453 1.15612 12000. 1.22047 1.19977 1.16049 12500. 1.22471 1.20399 1.16419 13000. 1.22730 1.20703 1.16715 13500. 1.22821 1.20879 1.16935 14000. 1.22750 1.20927 1.17073 14500. 1.22537 1.20853 1.17124 15000. 1.22216 1.20672 1.17091 15500. 1.21824 1.20403 1.16979 16000. 1.21348 1.20067 1.16799 16500. 1.20872 1.19684 1.16561 17000. 1.20397 1.19253 1.16275 17500. 1.19921 1.18822 1.15951 18000. 1.19427 1.18371 1.15600 18500. 1.18932 1.17919 1.15229 19000. 1.18438 1.17468 1.14845 20000. 1.17449 1.16565 1.14045 22500. 1.14948 1.14305 1.12047 25000. 1.12409 1.12045 1.10078 27500. 1.09828 1.09780 1.08137 30000. 1.07202 1.07509 1.06223 32500. 1.04530 1.05231 1.04333 35000. 1.01813 1.02945 1.02468 37500. 0.99060 1.00656 1.00630 40000. 0.96280 0.98368 0.98821 42500. 0.93491 0.96090 0.97046 45000. 0.90715 0.93833 0.95310 47500. 0.87980 0.91609 0.93618 50000. 0.85319 0.89434 0.91975 52500. 0.82767 0.87325 0.90387 55000. 0.80360 0.85302 0.88859 57500. 0.78133 0.83381 0.87397 60000. 0.76114 0.81579 0.86004 62500. 0.74321 0.79910 0.84687 65000. 0.72759 0.78385 0.83450 67500. 0.71425 0.77009 0.82295 70000. 0.70305 0.75784 0.81223 AREVA NP Inc.
Uontrolledi Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM M T
1OXM Fuel Page B-25 Table B.24 ] Hot Uncontrolled LPF Exposure 0.00 Void 0.40 Void 0.80 Void MI~d/MTU History History History 1.223 1.225
- 0. 1.275 1.221 1.225 100. 1.278 500. 1.276 1.217 1.222 1000. 1.273 1.212 1.218 1500. 1.269 1.207 1.215 2000. 1.265 1.203 1.211 2500. 1.261 1.201 1.207 3000. 1.257 1.198 1.204 3500. 1.252 1.194 1.200 4000. 1.248 1.191 1.196 4500. 1.243 1.188 1.192 5000. 1.238 1.185 1.188 5500. 1.233 1.181 1.185 6000. 1.227 1.178 1.181 6500. 1.222 1.174 1.177 7000. 1.217 1.170 1.173 7500. 1.211 1.166 1.169 8000. 1.205 1.162 1.165 8500. 1.199 1.158 1.161 9000. 1.193 1.154 1.157 9500. 1.187 1.150 1.153 10000. 1.180 1.146 1.149 10500. 1.173 1.141 1.145 11000. 1.166 1.137 1.142 11500. 1.159 1.132 1.138 12000. 1.153 1.127 1.135 12500. 1.146 1.123 1.132 13000. 1.141 1.119 1.129 13500. 1.135 1.115 1.126 14000. 1.131 1.112 1.124 14500. 1.128 1.109 1.122 15000. 1.124 1.107 1.120 15500. 1.121 1.105 1.118 16000. 1.119 1.103 1.116 16500. 1.117 1.102 1.115 17000. 1.114 1.100 1.113 17500. 1.112 1.099 1.112 18000. 1.110 1.098 1.111 18500. 1.109 1.097 1.109 19000. 1.107 1.096 1.108 20000. 1.104 1.094 1.106 22500. 1.101 1.092 1.101 25000. 1.098 1.091 1.095 27500. 1.095 1.089 1.091 30000. 1.092 1.087 1.090 32500. 1.089 1.086 1.089 35000. 1.086 1.084 1.088 37500. 1.082 1.082 1.087 40000. 1.078 1.080 1.086 42500. 1.074 1.078 1.085 45000. 1.073 1.075 1.083 47500. 1.072 1.073 1.082 50000. 1.069 1.070 1.080 52500. 1.064 1.067 1.079 55000. 1.058 1.064 1.077 57500. 1.051 1.061 1.075 60000. 1.045 1.058 1.073 62500. 1.042 1.055 1.071 65000. 1.044 1.052 1.069 67500. 1.052 1.051 1.068 70000. 1.061 1.056 1.067 AREVA NP Inc.
uontrollea uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-1 Appendix C Enriched Lattice Isotopic Data Tables The results in this appendix are based on hot operating and equilibrium xenon conditions.
AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-2 Table C.1 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.086 0.000 956.569 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.966 0.022 956.516 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.343 42.490 0.112 956.301 0.002 0.000 0.197 0.002 0.000 0.000 1000.0 0.341 41.903 0.222 956.032 0.003 0.000 0.419 0.007 0.000 0.000 1500.0 0.339 41.325 0.330 955.763 0.006 0.000 0.631 0.016 0.001 0.000 2000.0 0.337 40.755 0.436 955.494 0.008 0.000 0.832 0.028 0.003 0.000 2500.0 0.335 40.193 0.541 955.225 0.011 0.000 1.024 0.042 0.005 0.000 3000.0 0.333 39.639 0.643 954.955 0.013 0.000 1.206 0.059 0.008 0.000 3500.0 0.331 39.092 0.745 954.686 0.016 0.001 1.380 0.078 0.012 0.000 4000.0 0.329 38.552 0.844 954.416 0.019 0.001 1.545 0.098 0.017 0.000 4500.0 0.327 38.019 0.943 954.146 0.023 0.001 1.703 0.120 0.023 0.001 5000.0 0.325 37.492 1.040 953.877 0.026 0.001 1.853 0.143 0.030 0.001 5500.0 0.323 36.971 1.135 953.607 0.030 0.001 1.997 0.167 0.038 0.002 6000.0 0.322 36.456 1.229 953.337 0.034 0.002 2.134 0.193 0.047 0.002 6500.0 0.320 35.947 1.322 953.066 0.037 0.002 2.264 0.219 0.057 0.003 7000.0 0.318 35.444 1.413 952.796 0.041 0.002 2.388 0.246 0.068 0.004 7500.0 0.316 34.946 1.503 952.526 0.046 0.003 2.506 0.274 0.079 0.004 8000.0 0.314 34.453 1.592 952.256 0.050 0.003 2.619 0.303 0.091 0.006 8500.0 0.312 33.965 1.680 951.986 0.054 0.004 2.726 0.332 0.104 0.007 9000.0 0.311 33.482 1.767 951.716 0.059 0.004 2.828 0.362 0.117 0.008 9500.0 0.309 33.005 1.852 951.446 0.063 0.005 2.925 0.392 0.131 0.010 10000.0 0.307 32.531 1.936 951.175 0.068 0.006 3.017 0.422 0.146 0.011 10500.0 0.305 32.063 2.019 950.905 0.073 0.006 3.104 0.453 0.161 0.013 11000.0 0.303 31.598 2.101 950.636 0.078 0.007 3.187 0.485 0.176 0.015 11500.0 0.302 31.139 2.182 950.366 0.083 0.008 3.265 0.516 0.192 0.018 12000.0 0.300 30.683 2.262 950.096 0.088 0.009 3.340 0.548 0.208 0.020 12500.0 0.298 30.231 2.341 949.827 0.093 0.010 3.410 0.580 0.224 0.023 13000.0 0.296 29.783 2.419 949.557 0.099 0.011 3.476 0.612 0.241 0.025 13500.0 0.295 29.340 2.496 949.288 0.104 0.011 3.539 0.645 0.258 0.028 14000.0 0.293 28.900 2.572 949.020 0.110 0.013 3.597 0.677 0.274 0.032 14500.0 0.291 28.463 2.647 948.751 0.115 0.014 3.652 0.710 0.291 0.035 15000.0 0.290 28.031 2.721 948.483 0.121 0.015 3.704 0.743 0.308 0.039 15500.0 0.288 27.601 2.794 948.215 0.126 0.016 3.752 0.776 0.326 0.042 16000.0 0.286 27.176 2.867 947.948 0.132 0.017 3.798 0.808 0.343 0.046 16500.0 0.285 26.753 2.938 947.681 0.138 0.018 3.840 0.841 0.360 0.051 17000.0 0.283 26.334 3.009 947.413 0.143 0.020 3.879 0.874 0.377 0.055 17500.0 0.281 25.918 3.079 947.146 0.149 0.021 3.916 0.907 0.394 0.060 18000.0 0.280 25.505 3.147 946.879 0.155 0.023 3.950 0.940 0.411 0.064 18500.0 0.278 25.096 3.216 946.610 0.161 0.024 3.983 0.972 0.428 0.069 19000.0 0.276 24.690 3.283 946.342 0.167 0.026 4.013 1.005 0.445 0.075 19500.0 0.275 24.287 3.349 946.072 0.173 0.027 4.041 1.037 0.462 0.080 20000.0 0.273 23.888 3.415 945.801 0.179 0.029 4.068 1.070 0.478 0.086 20500.0 0.271 23.492 3.480 945.529 0.185 0.031 4.092 1.102 0.495 0.091 21000.0 0.270 23.099 3.544 945.256 0.191 0.033 4.116 1.134 0.512 0.098 22500.0 0.265 21.943 3.732 944.427 0.210 0.038 4.177 1.229 0.563 0.117 25000.0 0.257 20.084 4.028 943.017 0.242 0.050 4.254 1.382 0.645 0.154 27500.0 0.249 18.312 4.304 941.568 0.275 0.063 4.303 1.531 0.725 0.197 30000.0 0.241 16.627 4.561 940.078 0.310 0.077 4.327 1.673 0.799 0.245 32500.0 0.233 15.028 4.798 938.545 0.345 0.094 4.330 1.809 0.867 0.300 35000.0 0.225 13.517 5.015 936.967 0.380 0.113 4.316 1.937 0.929 0.359 37500.0 0.217 12.092 5.213 935.341 0.415 0.133 4.288 2.058 0.984 0.425 40000.0 0.209 10.757 5.391 933.665 0.451 0.155 4.248 2.170 1.032 0.495 42500.0 0.201 9.510 5.549 931.936 0.485 0.178 4.200 2.273 1.074 0.570 45000.0 0.193 8.353 5.688 930.151 0.519 0.202 4.144 2.368 1.109 0.651 47500.0 0.186 7.287 5.808 928.309 0.552 0.228 4.084 2.453 1.138 0.735 50000.0 0.178 6.311 5.908 926.408 0.584 0.254 4.022 2.529 1.160 0.823 52500.0 0.170 5.425 5.989 924.446 0.615 0.280 3.958 2.596 1.177 0.915 55000.0 0.163 4.628 6.051 922.422 0.644 0.307 3.895 2.654 1.190 1.010 57500.0 0.156 3.917 6.096 920.338 0.670 0.333 3.834 2.704 1.198 1.108 60000.0 0.149 3.290 6.124 918.194 0.695 0.358 3.777 2.745 1.202 1.207 62500.0 0.142 2.743 6.135 915.991 0.718 0.382 3.722 2.778 1.203 1.308 65000.0 0.135 2.270 6.131 913.733 0.739 0.405 3.672 2.804 1.202 1.410 67500.0 0.128 1.866 6.114 911.423 0.757 0.426 3.627 2.825 1.199 1.511 70000.0 0.122 1.525 6.085 909.067 0.773 0.446 3.586 2.839 1.195 1.613 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-3 Table C.2 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.000 0.000 0.0 0.345 43.086 0.000 956.569 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.967 0.023 956.509 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.342 42.492 0.116 956.265 0.002 0.000 0.222 0.002 0.000 0.000 1000.0 0.340 41.909 0.230 955.960 0.004 0.000 0.473 0.008 0.001 0.000 1500.0 0.338 41.335 0.342 955.655 0.007 0.000 0.711 0.018 0.003 0.000 2000.0 0.336 40.771 0.451 955.350 0.009 0.000 0.937 0.031 0.006 0.000 2500.0 0.334 40.215 0.559 955.045 0.012 0.000 1.153 0.047 0.010 0.000 3000.0 0.332 39.668 0.665 954.741 0.016 0.000 1.358 0.065 0.015 0.000 3500.0 0.329 39.129 0.768 954.436 0.019 0.001 1.554 0.085 0.022 0.001 4000.0 0.327 38.597 0.871 954.131 0.023 0.001 1.741 0.107 0.029 0.001 4500.0 0.325 38.073 0.971 953.827 0.027 0.001 1.919 0.131 0.038 0.001 5000.0 0.323 37.556 1.070 953.522 0.031 0.001 2.089 0.156 0.048 0.002 5500.0 0.321 37.045 1.167 953.217 0.035 0.002 2.252 0.182 0.058 0.003 6000.0 0.319 36.541 1.263 952.913 0.040 0.002 2.407 0.209 0.070 0.003 6500.0 0.317 36.043 1.358 952.608 0.044 0.003 2.555 0.237 7000.0 0.315 35.551 1.450 952.303 0.049 0.003 2.696 0.266 0.083 0.004 7500.0 0.313 35.065 1.542 951.999 0.054 0.004 2.831 0.295 0.097 0.005 8000.0 0.311 34.585 1.632 951.694 0.059 0.004 2.960 0.325 0.111 0.007 8500.0 0.309 34.110 1.721 951.390 0.064 0.005 3.083 0.356 0.126 0.008 9000.0 0.307 33.641 1.808 951.086 0.070 0.006 3.200 0.387 0.142 0.010 9500.0 0.305 33.176 1.894 950.782 0.075 0.007 3.311 0.419 0.158 0.011 10000.0 0.303 32.717 1.979 950.478 0.081 0.007 3.418 0.451 0.175 0.013 10500.0 0.301 32.263 2.062 950.174 0.087 0.008 3.519 0.484 0.193 0.015 11000.0 0.299 31.813 2.145 949.870 0.092 0.009 3.616 0.517 0.211 0.018 11500.0 0.297 31.368 2.226 949.567 0.098 0.010 3.708 0.550 0.229 0.020 12000.0 0.295 30.928 2.306 949.264 0.104 0.011 3.795 0.583 0.248 0.023 12500.0 0.293 30.492 2.385 948.961 0.111 0.012 3.878 0.617 0.267 0.026 13000.0 0.291 30.060 2.463 948.658 0.117 0.014 3.956 0.651 0.286 0.029 13500.0 0.290 29.632 2.539 948.356 0.123 0.015 4.031 0.685 0.305 0.032 14000.0 0.288 29.209 2.615 948.054 0.129 0.016 4.101 0.719 0.325 0.036 14500.0 0.286 28.789 2.690 947.752 0.136 0.018 4.168 0.753 0.344 0.039 15000.0 0.284 28.373 2.764 947.450 0.142 0.019 4.231 0.788 0.364 0.043 15500.0 0.282 27.961 2.836 947.149 0.149 0.021 4.290 0.822 0.384 0.047 16000.0 0.280 27.553 2.908 946.849 0.155 0.022 4.346 0.857 0.404 0.052 16500.0 0.279 27.148 2.979 946.548 0.162 0.024 4.398 0.892 0.423 0.056 17000.0 0.277 26.747 3.049 946.248 0.168 0.026 4.448 0.926 0.443 0.061 17500.0 0.275 26.349 3.118 945.948 0.175 0.027 4.494 0.961 0.462 0.066 18000.0 0.273 25.954 3.186 945.648 0.182 0.029 4.538 0.995 0.482 0.071 18500.0 0.272 25.563 3.253 945.348 0.189 0.031 4.579 1.030 0.501 0.076 19000.0 0.270 25.175 3.319 945.048 0.195 0.033 4.618 1.064 0.521 0.082 19500.0 0.268 24.791 3.385 944.747 0.202 0.035 4.655 1.098 0.540 0.088 20000.0 0.266 24.410 3.449 944.445 0.209 0.037 4.690 1.132 0.559 0.094 20500.0 0.265 24.032 3.513 944.142 0.216 0.040 4.722 1.166 0.578 0.100 21000.0 0.263 23.658 3.576 943.839 0.223 0.042 4.753 1.200 0.598 0.106 21500.0 0.261 23.287 3.638 943.534 0.230 0.044 4.783 1.234 0.617 0.113 22000.0 0.259 22.920 3.699 943.228 0.237 0.047 4.811 1.267 0.636 0.120 22500.0 0.258 22.556 3.760 942.921 0.244 0.049 4.837 1.300 0.655 0.127 25000.0 0.249 20.789 4.049 941.365 0.281 0.063 4.948 1.463 0.749 0.165 27500.0 0.241 19.107 4.318 939.773 0.318 0.079 5.029 1.619 0.839 0.208 30000.0 0.233 17.508 4.567 938.145 0.356 0.098 5.083 1.770 0.925 0.257 32500.0 0.225 15.994 4.797 936.480 0.395 0.118 5.115 1.914 1.005 0.311 35000.0 0.217 14.561 5.007 934.776 0.433 0.140 5.127 2.051 1.078 0.369 37500.0 0.209 13.210 5.197 933.032 0.472 0.165 5.123 2.180 1.145 0.432 40000.0 0.201 11.939 5.370 931.247 0.510 0.191 5.104 2.301 1.206 0.499 42500.0 0.194 10.748 5.523 929.419 0.547 0.219 5.075 2.414 1.260 0.570 45000.0 0.186 9.636 5.659 927.548 0.583 0.248 5.036 2.519 1.307 0.645 47500.0 0.179 8.602 5.777 925.633 0.618 0.279 4.991 2.616 1.347 0.724 50000.0 0.172 7.645 5.877 923.673 0.652 0.310 4.939 2.703 1.382 0.805 52500.0 0.165 6.764 5.961 921.667 0.685 0.342 4.885 2.783 1.411 0.889 55000.0 0.158 5.956 6.028 919.617 0.716 0.375 4.828 2.854 1.434 0.976 57500.0 0.152 5.221 6.080 917.521 0.745 0.407 4.770 2.917 1.453 1.064 60000.0 0.145 4.555 6.116 915.380 0.772 0.439 4.713 2.972 1.467 1.154 62500.0 0.139 3.955 6.138 913.196 0.797 0.470 4.657 3.019 1.477 1.245 65000.0 0.133 3.419 6.146 910.971 0.820 0.500 4.602 3.060 1.484 1.337 67500.0 0.128 2.943 6.141 908.705 0.841 0.528 4.550 3.094 1.488 1.429 70000.0 0.122 2.522 6.126 906.401 0.860 0.556 4.501 3.122 1.489 1.521 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-4 Table C.3 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.086 0.000 956.569 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.967 0.024 956.499 0.000 0.000 0.027 0.000 0.000 0.000 500.0 0.342 42.497 0.122 956.218 0.002 0.000 0.254 0.002 0.000 0.000 1000.0 0.340 41.919 0.241 955.866 0.005 0.000 0.540 0.009 0.001 0.000 1500.0 0.337 41.352 0.357 955.514 0.008 0.000 0.812 0.020 0.002 0.000 2000.0 0.335 40.795 0.471 955.162 0.011 0.000 1.072 0.034 0.004 0.000 2500.0 0.332 40.248 0.583 954.811 0.015 0.000 1.319 0.051 0.008 0.000 3000.0 0.330 39.710 0.693 954.460 0.019 0.001 1.555 0.071 0.013 0.000 3500.0 0.327 39.181 0.800 954.109 0.023 0.001 1.780 0.093 0.020 0.000 4000.0 0.325 38.660 0.906 953.759 0.028 0.001 1.996 0.116 0.028 0.001 4500.0 0.322 38.146 1.010 953.408 0.033 0.002 2.202 0.141 0.037 0.001 5000.0 0.320 37.641 1.112 953.057 0.038 0.002 2.399 0.167 0.048 0.002 5500.0 0.318 37.142 1.212 952.707 0.043 0.003 2.589 0.195 0,059 0.002 6000.0 0.315 36.651 1.310 952.357 0.048 0.003 2.770 0.223 0.073 0.003 6500.0 0.313 36.166 1.407 952.007 0.054 0.004 2.943 0.252 0.087 0.004 7000.0 0.311 35.688 1.502 951.657 0.060 0.005 3.110 0.283 0.102 0.005 7500.0 0.308 35.216 1.596 951.307 0.066 0.005 3.269 0.314 0.118 0.006 8000.0 0.306 34.750 1.688 950.957 0.072 0.006 3.422 0.345 0.135 0.007 8500.0 0.304 34.290 1.778 950.607 0.079 0.007 3.569 0.377 0.152 0.009 9000.0 0.302 33.835 1.867 950.258 0.085 0.008 3.709 0.410 0.171 0.011 9500.0 0.299 33.387 1.955 949.909 0.092 0.009 3.844 0.444 0.190 0.013 10000.0 0.297 32.943 2.042 949.560 0.099 0.010 3.973 0.478 0.209 0.015 10500.0 0.295 32.505 2.127 949.211 0.105 0.012 4.096 0.512 0.229 0.017 11000.0 0.293 32.071 2.210 948.862 0.112 0.013 4.215 0.546 0.250 0.020 11500.0 0.291 31.643 2.293 948.514 0.119 0.014 4.328 0.581 0.271 0.022 12000.0 0.289 31.220 2.374 948.166 0.127 0.016 4.436 0.617 0.292 0.025 12500.0 0.287 30.801 2.454 947.818 0.134 0.017 4.540 0.652 0.314 0.028 13000.0 0.284 30.387 2.532 947.470 0.141 0.019 4.639 0.688 0.335 0.031 13500.0 0.282 29.977 2.610 947.123 0.149 0.021 4.734 0.725 0.357 0.035 14000.0 0.280 29.571 2.686 946.776 0.156 0.023 4.825 0.761 0.379 0.039 14500.0 0.278 29.170 2.761 946.429 0.164 0.025 4.911 0.798 0.402 0.042 15000.0 0.276 28.773 2.835 946.083 0.172 0.027 4.994 0.834 0.424 0.046 15500.0 0.274 28.380 2.908 945.737 0.179 0.029 5.072 0.871 0.446 0.051 16000.0 0.272 27.991 2.980 945.391 0.187 0.031 5.147 0.908 0.469 0.055 16500.0 0.270 27.606 3.051 945.046 0.195 0.033 5.218 0.945 0.491 0.060 17000.0 0.268 27.224 3.121 944.701 0.203 0.035 5.286 0.982 0.514 0.065 17500.0 0.266 26.847 3.190 944.356 0.210 0.038 5.351 1.020 0.536 0.070 18000.0 0.265 26.472 3.257 944.011 0.218 0.040 5.412 1.057 0.558 0.075 18500.0 0.263 26.102 3.324 943.666 0.226 0.043 5.470 1.094 0.580 0.080 19000.0 0.261 25.735 3.390 943.322 0.234 0.046 5.526 1.131 0.602 0.086 19500.0 0.259 25.371 3.455 942.977 0.242 0.049 5.579 1.169 0.624 0.091 20000.0 0.257 25.011 3.519 942.632 0.250 0.051 5.630 1.206 0.646 0.097 20500.0 0.255 24.654 3.582 942.286 0.258 0.054 5.678 1.243 0.668 0.104 21000.0 0.253 24.301 3.644 941.940 0.266 0.058 5.724 1.280 0.690 0.110 21500.0 0.252 23.951 3.706 941.593 0.274 0.061 5.768 1.316 0.711 0.116 22000.0 0.250 23.604 3.766 941.246 0.282 0.064 5.810 1.353 0.733 0.123 22500.0 0.248 23.261 3.826 940.897 0.290 0.067 5.851 1.389 0.754 0.130 23000.0 0.246 22.921 3.884 940.548 0.299 0.071 5.890 1.426 0.776 0.137 23500.0 0.244 22.585 3.942 940.197 0.307 0.074 5. 927 1.462 0.797 0.144 24000.0 0.243 22.252 3.999 939.846 0.315 0.078 5. 962 1.498 0.818 0.152 24500.0 0.241 21.923 4.055 939.493 0.323 0.082 5.996 1.534 0.839 0.159 25000.0 0.239 21.596 4.111 939.139 0.331 0.086 6.029 1.569 0.860 0.167 25500.0 0.237 21.273 4.165 938.784 0.340 0.090 6.060 1.605 0.881 0.175 26000.0 0.236 20.954 4.219 938.428 0.348 0.094 6.090 1.640 0.902 0.183 27500.0 0.230 20.015 4.375 937.351 0.373 0.107 6.173 1.744 0.963 0.208 30000.0 0.222 18.514 4.619 935.530 0.415 0.130 6.289 1.913 1.063 0.254 32500.0 0.214 17.094 4.843 933.677 0.456 0.156 6.379 2.075 1.159 0.304 35000.0 0.206 15.750 5.048 931.791 0.498 0.184 6.447 2.231 1.249 0.357 37500.0 0.198 14.483 5.234 929.872 0.539 0.215 6.495 2.381 1.333 0.414 40000.0 0.190 13.289 5.401 927.920 0.580 0.248 6.527 2.523 1.411 0.475 42500.0 0.183 12.167 5.551 925.935 0.620 0.283 6.544 2.658 1.484 0.538 45000.0 0.176 11.116 5.684 923.916 0.658 0.319 6.549 2.786 1.551 0.605 47500.0 0.169 10.132 5.799 921.864 0.696 0.357 6.543 2.906 1.612 0.674 50000.0 0.162 9.215 5.899 919.780 0.732 0.397 6.529 3.019 1.667 0.745 52500.0 0.156 8.361 5.984 917.663 0.767 0.437 6.508 3.124 1.717 0.819 55000.0 0.150 7.569 6.053 915.515 0.800 0.478 6.481 3.221 1.761 0.894 57500.0 0.144 6.837 6.109 913.335 0.831 0.519 6.449 3.311 1.801 0.972 60000.0 0.139 6.161 6.151 911.125 0.860 0.561 6.415 3.394 1.836 1.051 62500.0 0.133 5.540 6.180 908.886 0.887 0.602 6.377 3.470 1.866 1.131 65000.0 0.128 4.971 6.198 906.619 0.913 0.643 6.339 3.539 1.893 1.213 67500.0 0.124 4.451 6.204 904.325 0.936 0.683 6.299 3.601 1.916 1.296 70000.0 0.119 3.978 6.200 902.006 0.957 0.722 6.260 3.658 1.935 1.380 AREVA NP Inc.
Lontrolled Vocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-5 Table C.4 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU u-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0,000 0.000 0.0 0.344 43.029 0.000 956.627 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.909 0.023 956.573 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.342 42.433 0.112 956.354 0.002 0.000 0.200 0.002 0.000 0.000 1000.0 0.340 41.846 0.223 956.082 0.004 0.000 0.426 0.007 0.001 0.000 1500.0 0.338 41.269 0.331 955.809 0.006 0.000 0.640 0.016 0.003 0.000 2000.0 0.336 40.700 0.437 955.536 0.008 0.000 0.844 0.028 0.005 0.000 2500.0 0.334 40.139 0.542 955.263 0.011 0.000 1.037 0.043 0.008 0.000 3000.0 0.332 39.586 0.645 954.990 0.014 0.000 1.221 0.060 0.012 0.000 3500.0 0.330 39.040 0.746 954.718 0.017 0.001 1.397 0.079 0.018 0.001 4000.0 0.329 38.501 0.846 954.445 0.020 0.001 1.564 0.100 0.024 0.001 4500.0 0.327 37.969 0.944 954.173 0.023 0.001 1.722 0.122 0.031 0.001 5000.0 0.325 37.443 1.041 953.900 0.027 0.001 1.873 0.146 0.039 0.002 5500.0 0.323 36.924 1.137 953.628 0.030 0.001 2.017 0.170 0.048 0.002 6000.0 0.321 36.410 1.231 953.356 0.034 0.002 2.154 0.196 0.058 0.003 6500.0 0.319 35.903 1.323 953.084 0.038 0.002 2.285 0.223 7000.0 0.317 35.401 1.415 952.813 0.042 0.003 2.409 0.250 0.069 0.004 7500.0 0.315 34.904 1.505 952.541 0.046 0.003 2.527 0.278 0.081 0.005 8000.0 0.314 34.412 1.593 952.270 0.051 0.003 2.639 0.307 0.093 0.006 8500.0 0.312 33.926 1.681 951.999 0.055 0.004 2.745 0.337 0.106 0.007 9000.0 0.310 33.444 1.768 951.728 0.059 0.005 2.846 0.367 0.120 0.008 9500.0 0.308 32.967 1.853 951.458 0.064 0.005 2.942 0.397 0.134 0.010 10000.0 0.306 32.495 1.937 951.188 0.069 0.006 3.033 0.428 0.148 0.012 10500.0 0.305 32.027 2.020 950.918 0.074 0.006 3.119 0.459 0.163 0.014 11000.0 0.303 31.564 2.102 950.649 0.079 0.007 3.200 0.490 0.179 0.016 11500.0 0.301 31.104 2.183 950.381 0.084 0.008 3.277 0.522 0.194 0.018 12000.0 0.299 30.649 2.262 950.112 0.089 0.009 3.349 0.554 0.210 0.021 12500.0 0.298 30.198 2.341 949.845 0.094 0.010 3.417 0.586 0.227 0.023 13000.0 0.296 29.750 2.419 949.578 0.099 0.011 3.482 0.619 0.243 0.026 13500.0 0.294 29.307 2.496 949.311 0.104 0.012 3.542 0.651 0.260 0.029 14000.0 0.292 28.866 2.572 949.045 0.110 0.013 3.598 0.684 0.276 0.032 14500.0 0.291 28.430 2.647 948.780 0.115 0.014 3.651 0.716 0.293 0.036 15000.0 0.289 27.996 2.721 948.515 0.121 0.015 3.701 0.749 0.310 0.039 15500.0 0.287 27.566 2.794 948.250 0.126 0.016 3.747 0.782 0.326 0.043 16000.0 0.286 27.139 2.866 947.986 0.132 0.017 3.791 0.815 0.343 0.047 16500.0 0.284 26.716 2.937 947.721 0.137 0.018 3.832 0.847 0.360 0.051 17000.0 0.282 26.296 3.008 947.456 0.143 0.020 3.870 0.880 0.377 0.056 17500.0 0.281 25.880 3.078 947.190 0.149 0.021 3.907 0.913 0.394 0.060 18000.0 0.279 25.466 3.147 946.923 0.155 0.023 3.941 0.945 0.411 0.065 18500.0 0.278 25.057 3.215 946.656 0.160 0.024 3.973 0.978 0.428 0.070 19000.0 0.276 24.650 3.282 946.387 0.166 0.026 4.003 1.010 0.445 0.075 19500.0 0.274 24.248 3.349 946.118 0.172 0.027 4.031 1.042 0.462 0.081 20000.0 0.273 23.848 3.414 945.847 0.178 0.029 4.058 1.074 0.479 0.086 20500.0 0.271 23.453 3.479 945.575 0.184 0.031 4.083 1.106 0.496 0.092 21000.0 0.269 23.060 3.543 945.301 0.190 0.033 4.106 1.138 0.513 0.098 21500.0 0.268 22.671 3.606 945.026 0.197 0.034 4.129 1.170 0.530 0.104 22500.0 0.265 21.904 3.730 944.472 0.209 0.038 4.169 1.233 0.563 0.118 25000.0 0.256 20.047 4.026 943.060 0.242 0.050 4.247 1.386 0.646 0.155 27500.0 0.248 18.276 4.303 941.610 0.275 0.063 4.296 1.533 0.725 0.198 30000.0 0,240 16.592 4.559 940.118 0.309 0.077 4.321 1.675 0.799 0.246 32500.0 0,232 14.995 4.796 938.584 0.344 0.094 4.325 1.811 0.867 0.301 35000.0 0,224 13.485 5.012 937.004 0.380 0.113 4.312 1.939 0.929 0.361 37500.0 0.216 12.063 5.210 935.376 0.415 0.133 4.284 2.059 0.984 0.426 40000.0 0,208 10.730 5.387 933.698 0.450 0.155 4.245 2.171 1.033 0.497 42500.0 0,201 9.485 5.545 931.966 0.485 0.178 4.196 2.274 1.074 0.572 45000.0 0,193 8.331 5.684 930.180 0.519 0.203 4.141 2.369 1.109 0.652 47500.0 0.185 7.267 5.803 928.336 0.552 0.228 4.081 2.454 1.137 0.737 50000.0 0,178 6.293 5.902 926.432 0.584 0.254 4.019 2.530 1.160 0.825 52500.0 0.170 5.409 5.983 924.468 0.614 0.280 3.956 2.597 1.177 0.917 55000.0 0.163 4.614 6.045 922.443 0.643 0.307 3.893 2.655 1.189 1.012 57500.0 0.155 3.905 6.090 920.357 0.670 0.333 3.833 2.704 1.197 1.110 60000.0 0.148 3.280 6.117 918.211 0.695 0.358 3.775 2.745 1.202 1.209 62500.0 0.141 2.735 6.128 916.007 0.718 0.382 3.721 2.778 1.203 1.310 65000.0 0.135 2.263 6.124 913.747 0.738 0.405 3.671 2.805 1.202 1.411 67500.0 0.128 1.861 6.107 911.436 0.756 0.426 3.626 2.825 1.199 1.513 70000.0 0.122 1.521 6.077 909.078 0.772 0.445 3.585 2.840 1.195 1.614 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-6 Table C.5 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU u-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.344 43.029 0.000 956.627 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.910 0.023 956.565 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.342 42.435 0.116 956.318 0.002 0.000 0.226 0.002 0.000 0.000 1000.0 0.340 41.852 0.231 956.009 0.004 0.000 0.480 0.008 0.000 0.000 1500.0 0.338 41.279 0.343 955.699 0.007 0.000 0.721 0.018 0.001 0.000 2000.0 0.335 40.715 0.453 955.391 0.010 0.000 0.950 0.032 0.003 0.000 2500.0 0.333 40.161 0.560 955.082 0.013 0.000 1.168 0.048 0.006 0.000 3000.0 0.331 39.615 0.666 954.774 0.016 0.000 1.375 0.066 0.011 0.000 3500.0 0.329 39.077 0.770 954.466 0.020 0.001 1.573 0.087 0.016 0.000 4000.0 0.327 38.546 0.873 954.158 0.023 0.001 1.761 0.109 0.022 0.001 4500.0 0.325 38.023 0.973 953.851 0.027 0.001 1.940 0.133 0.030 0.001 5000.0 0.322 37.507 1.072 953.543 0.031 0.002 2.111 0.158 0.039 0.001 5500.0 0.320 36.998 1.169 953.236 0.036 0.002 2.274 0.185 0.049 0.002 6000.0 0.318 36.495 1.265 952.929 0.040 0.002 2.430 0.212 0.060 0.003 6500.0 0.316 35.999 1.359 952.623 0.045 0.003 2.578 0.240 0.072 0.003 7000.0 0.314 35.508 1.452 952.316 0.050 0.003 2.719 0.269 0.085 0.004 7500.0 0.312 35.023 1.544 952.010 0.055 0.004 2.854 0.299 0.099 0.006 8000.0 0.310 34.544 1.633 951.705 0.060 0.005 2.982 0.330 0.113 0.007 8500.0 0.308 34.071 1.722 951.399 0.065 0.005 3.104 0.361 0.129 0.008 9000.0 0.306 33.603 1.809 951.095 0.070 0.006 3.220 0.392 0.145 0.010 9500.0 0.304 33.140 1.895 950.790 0.076 0.007 3.331 0.424 0.161 0.012 10000.0 0.302 32.681 1.980 950.486 0.081 0.008 3.436 0.456 0.178 0.014 10500.0 0.300 32.228 2.063 950.182 0.087 0.008 3.536 0.489 0.196 0.016 11000.0 0.298 31.779 2.145 949.879 0.093 0.009 3.631 0.522 0.214 0.018 11500.0 0.296 31.335 2.226 949.577 0.099 0.010 3.722 0.556 0.232 0.021 12000.0 0.295 30.896 2.306 949.275 0.105 0.012 3.807 0.589 0.251 0.023 12500.0 0.293 30.460 2.385 948.973 0.111 0.013 3.888 0.623 0.270 0.026 13000.0 0.291 30.029 2.463 948.672 0.117 0.014 3.964 0.657 0.289 0.029 13500.0 0.289 29.601 2.539 948.372 0.123 0.015 4.037 0.691 0.308 0.033 14000.0 0,287 29.178 2.615 948.073 0.130 0.016 4.105 0.726 0.327 0.036 14500.0 0,285 28.758 2.689 947.774 0.136 0.018 4.169 0.760 0.347 0.040 15000.0 0,283 28.342 2.763 947.475 0.142 0.019 4.230 0.795 0.366 0.044 15500.0 0,282 27.930 2.836 947.177 0.149 0.021 4.287 0.829 0.385 0.048 16000.0 0,280 27.521 2.907 946.880 0.155 0.022 4.341 0.864 0.405 0.052 16500.0 0,278 27.115 2.978 946.582 0.162 0.024 4.392 0.898 0.424 0.057 17000.0 0,276 26.713 3.048 946.284 0.168 0.026 4.440 0.933 0.444 0.062 17500.0 0,275 26.315 3.117 945.986 0.175 0.028 4.485 0.967 0.463 0.067 18000.0 0.273 25.920 3.185 945.688 0.182 0.029 4.528 1.001 0.482 0.072 18500.0 0,271 25.528 3.252 945.389 0.188 0.031 4.569 1.036 0.502 0.077 19000.0 0.269 25.140 3.318 945.090 0.195 0.033 4.607 1.070 0.521 0.083 19500.0 0,268 24.755 3.384 944.790 0.202 0.035 4.644 1.104 0.540 0.088 20000.0 0.266 24.374 3.448 944.488 0.209 0.038 4.679 1.138 0.560 0.094 20500.0 0.264 23.996 3.512 944.186 0.216 0.040 4.711 1.171 0.579 0.101 21000.0 0.262 23.622 3.575 943.882 0.223 0.042 4.743 1.205 0.598 0.107 21500.0 0.261 23.251 3.637 943.577 0.230 0.044 4.772 1.238 0.617 0.114 22000.0 0.259 22.884 3.698 943.271 0.237 0.047 4.800 1.272 0.636 0.120 22500.0 0.257 22.521 3.758 942.964 0.244 0.049 4.827 1.305 0.655 0.127 23000.0 0.256 22.160 3.818 942.655 0.251 0.052 4.852 1.338 0.674 0.135 25000.0 0.249 20.754 4.048 941.407 0.280 0.063 4.939 1.467 0.749 0.166 27500.0 0.241 19.072 4.317 939.814 0.318 0.079 5.021 1.623 0.840 0.209 30000.0 0.232 17.475 4.565 938.185 0.356 0.098 5.076 1.773 0.925 0.258 32500.0 0.224 15.962 4.794 936.518 0.395 0.118 5.109 1.916 1.005 0.312 35000.0 0.216 14.531 5.004 934.812 0.433 0.141 5.122 2.052 1.079 0.370 37500.0 0.208 13.181 5.194 933.067 0.471 0.165 5.118 2.181 1.146 0.433 40000.0 0.201 11.912 5.366 931.280 0.509 0.191 5.100 2.303 1.206 0.501 42500.0 0.193 10.723 5.519 929.451 0.547 0.219 5.071 2.416 1.260 0.572 45000.0 0.186 9.613 5.655 927.578 0.583 0.249 5.033 2.520 1.307 0.647 47500.0 0.179 8.581 5.772 925.661 0.618 0.279 4.987 2.616 1.347 0.725 50000.0 0.171 7.626 5.872 923.699 0.652 0.310 4.936 2.704 1.382 0.807 52500.0 0.165 6.746 5.956 921.692 0.684 0.342 4.882 2.783 1.410 0.891 55000.0 0.158 5.940 6.023 919.640 0.715 0.375 4.825 2.854 1.434 0.977 57500.0 0.151 5.206 6.074 917.542 0.744 0.407 4.768 2.917 1.452 1.066 60000.0 0.145 4.542 6.109 915.400 0.771 0.439 4.711 2.972 1.466 1.155 62500.0 0.139 3.944 6.131 913.215 0.797 0.470 4.655 3.019 1.477 1.246 65000.0 0.133 3.410 6.139 910.988 0.820 0.500 4.601 3.060 1.483 1.338 67500.0 0.127 2.935 6.134 908.721 0.841 0.528 4.549 3.094 1.487 1.430 70000.0 0.122 2.516 6.118 906.416 0.860 0.556 4.500 3.122 1.489 1.523 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM 1OXM Fuel M
T Page C-7 Table C.6 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.344 0.000 0.000 0.000 100.0 0.344 43.029 0.000 956.627 0.000 0.000 0.000 0.000 0.000 0.000 500.0 0.342 42.910 0.025 956.556 0.000 0.000 0.027 0.002 0.000 0.000 42.439 0.122 956.270 0.002 0.000 0.258 0.009 0.001 0.000 1000.0 0.339 41.862 0.242 955.913 0.005 0.000 0.548 0.020 0.002 0.000 1500.0 0.336 41.295 0.358 955.557 0.008 0.000 0.824 0.035 0.005 0.000 2000.0 0.334 40.739 0.473 955.201 0.012 0.000 1.086 0.052 0.008 0.000 2500.0 0.331 40.193 0.585 954.846 0.015 0.000 1.336 0.072 0.014 0.000 3000.0 0.329 39.656 0.695 954.491 0.019 0.001 1.574 0.094 0.020 0.000 3500.0 0.326 39.128 0.802 954.137 0.024 0.001 1.801 0.118 0.029 0.001 4000.0 0.324 38.608 0.908 953.783 0.028 0.001 2.018 0.143 0.038 0.001 4500.0 0.322 38.096 1.012 953.429 0.033 0.002 2.226 0.170 0.049 0.002 5000.0 0.319 37.592 1.114 953.076 0.038 0.002 2.424 0.197 0.061 0.002 5500.0 0.317 37.095 1.214 952.723 0.043 0.003 2.614 0.226 0.074 0.003 6000.0 0.315 36.605 1.313 952.370 0.049 0.003 2.796 0.256 0.089 0.004 6500.0 0.312 36.122 1.409 952.018 0.055 0.004 2.970 7000.0 0.310 35.645 1.504 951.666 0.061 0.005 3.136 0.286 0.104 0.005 7500.0 0.308 35.174 1.598 951.314 0.067 0.005 3.295 0.317 0.120 0.006 8000.0 0.305 34.709 1.690 950.963 0.073 0.006 3.448 0.349 0.137 0.008 8500.0 0.303 34.251 1.780 950.612 0.079 0.007 3.594 0.382 0.155 0.009 9000.0 0.301 33.798 1.869 950.262 0.086 0.008 3.734 0.415 0.174 0.011 9500.0 0.299 33.350 1.957 949.912 0.093 0.009 3.868 0.448 0.193 0.013 10000.0 0.296 32.908 2.043 949.563 0.099 0.011 3.995 0.483 0.213 0.015 10500.0 0.294 32.471 2.128 949.214 0.106 0.012 4.118 0.517 0.233 0.017 11000.0 0.292 32.038 2.211 948.866 0.113 0.013 4.235 0.552 0.253 0.020 11500.0 0.290 31.611 2.293 948.518 0.120 0.015 4.347 0.587 0.274 0.023 12000.0 0.288 31.188 2.374 948.170 0.127 0.016 4.453 0.623 0.296 0.026 12500.0 0.286 30.771 2.454 947.823 0.135 0.018 4.555 0.659 0.317 0.029 13000.0 0.284 30.357 2.532 947.477 0.142 0.019 4.653 0.695 0.339 0.032 13500.0 0.282 29.948 2.610 947.131 0.149 0.021 4.745 0.731 0.361 0.035 14000.0 0.280 29.543 2.686 946.786 0.157 0.023 4.834 0.768 0.383 0.039 14500.0 0.278 29.142 2.761 946.441 0.164 0.025 4.918 0.805 0.405 0.043 15000.0 0.276 28.745 2.835 946.097 0.172 0.027 4.998 0.841 0.427 0.047 15500.0 0.274 28.352 2.908 945.754 0.180 0.029 5.074 0.878 0.449 0.051 16000.0 0.272 27.963 2.979 945.411 0.187 0.031 5.147 0.915 0.471 0.056 16500.0 0.270 27.578 3.050 945.068 0.195 0.033 5.216 0.953 0.493 0.060 17000.0 0.268 27.196 3.120 944.726 0.203 0.036 5.282 0.990 0.515 0.065 17500.0 0.266 26.818 3.188 944.383 0.210 0.038 5.345 1.027 0.537 0.070 18000.0 0.264 26.443 3.256 944.041 0.218 0.041 5.404 1.064 0.559 0.076 18500.0 0.262 26.072 3.323 943.699 0.226 0.043 5.461 1.101 0.581 0.081 19000.0 0.260 25.705 3.389 943.356 0.234 0.046 5.516 1.138 0.603 0.086 19500.0 0.258 25.341 3.453 943.013 0.242 0.049 5.568 1.175 0.625 0.092 20000.0 0.257 24.980 3.517 942.669 0.250 0.052 5.618 1.212 0.647 0.098 20500.0 0.255 24.623 3.580 942.325 0.258 0.055 5.666 1.249 0.669 0.104 21000.0 0.253 24.270 3.643 941.979 0.266 0.058 5.711 1.286 0.690 0.111 21500.0 0.251 23.920 3.704 941.633 0.274 0.061 5.755 1.322 0.712 0.117 22000.0 0.249 23.573 3.764 941.286 0.282 0.064 5.797 1.359 0.733 0.124 22500.0 0.247 23.230 3.824 940.938 0.290 0.067 5.838 1.395 0.755 0.131 23000.0 0.246 22.890 3.882 940.588 0.298 0.071 5.877 1.431 0.776 0.138 23500.0 0.244 22.554 3.940 940.238 0.306 0.074 5.914 1.467 0.798 0.145 24000.0 0.242 22.221 3.997 939.886 0.315 0.078 5.950 1.503 0.819 0.152 24500.0 0.240 21.891 4.053 939.533 0.323 0.082 5.984 1.538 0.840 0.160 25000.0 0.239 21.565 4.109 939.179 0.331 0.086 6.017 1.574 0.861 0.168 25500.0 0.237 21.242 4.163 938.824 0.339 0.090 6.049 1.609 0.882 0.176 27500.0 0.230 19.984 4.373 937.390 0.372 0.107 6.163 1.748 0.965 0.209 30000.0 0.221 18.484 4.616 935.567 0.414 0.130 6.280 1.916 1.065 0.255 32500.0 0.213 17.065 4.840 933.713 0.456 0.156 6.371 2.077 1.160 0.305 35000.0 0.205 15.723 5.045 931.826 0.498 0.184 6.440 2.233 1.250 0.358 37500.0 0.197 14.456 5.230 929.905 0.539 0.215 6.489 2.382 1.334 0.416 40000.0 0.190 13.264 5.398 927.952 0.580 0.248 6.521 2.524 1.412 0.476 42500.0 0.183 12.143 5.547 925.965 0.619 0.283 6.539 2.659 1.485 0.540 45000.0 0.176 11.093 5.679 923.946 0.658 0.319 6.545 2.787 1.551 0.606 47500.0 0.169 10.111 5.795 921.893 0.696 0.357 6.539 2.907 1.612 0.675 50000.0 0.162 9.195 5.894 919.807 0.732 0.397 6.526 3.019 1.667 0.747 52500.0 0.156 8.343 5.978 917.689 0.766 0.437 6.505 3.124 1.717 0.820 55000.0 0.150 7.552 6.047 915.539 0.799 0.478 6.478 3.221 1.761 0.896 57500.0 0.144 6.821 6.103 913.358 0.830 0.519 6.447 3.311 1.801 0.973 60000.0 0.138 6.147 6.145 911.147 0.859 0.561 6.412 3.394 1.836 1.052 62500.0 0.133 5.527 6.174 908.907 0.887 0.602 6.375 3.470 1.866 1.133 65000.0 0.128 4.960 6.191 906.639 0.912 0.643 6.337 3.538 1.893 1.214 67500.0 0.123 4.441 6.197 904.344 0.935 0.683 6.298 3.601 1.915 1.297 70000.0 0.119 3.968 6.193 902.024 0.956 0.722 6.258 3.657 1.935 1.381 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-8 Table C.7 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 u-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.563 0.000 956.089 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.348 43.443 0.022 956.040 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.347 42.965 0.110 955.844 0.001 0.000 0.176 0.001 0.000 0.000 1000.0 0.345 42.376 0.218 955.598 0.003 0.000 0.379 0.006 0.000 0.000 1500.0 0.343 41.794 0.324 955.353 0.005 0.000 0.573 0.014 0.001 0.000 2000.0 0.341 41.220 0.429 955.107 0.007 0.000 0.758 0.025 0.002 0.000 2500.0 0.339 40.653 0.533 954.862 0.010 0.000 0.934 0.038 0.004 0.000 3000.0 0.338 40.094 0.634 954.616 0.012 0.000 1.101 0.053 0.006 0.000 3500.0 0.336 39.540 0.735 954.371 0.015 0.000 1.261 0.070 0.010 0.000 4000.0 0.334 38.993 0.833 954.125 0.018 0.001 1.413 0.088 0.014 0.000 4500.0 0.332 38.452 0.931 953.880 0.021 0.001 1.558 0.109 0.019 0.001 5000.0 0.330 37.917 1.027 953.635 0.024 0.001 1.695 0.130 0.025 0.001 5500.0 0.329 37.387 1.122 953.390 0.027 0.001 1.826 0.153 0.032 0.001 6000.0 0.327 36.863 1.216 953.145 0.030 0.001 1.951 0.176 0.039 0.002 6500.0 0.325 36.344 1.308 952.901 0.034 0.002 2.070 0.201 0.047 0.002 7000.0 0.323 35.830 1.399 952.656 0.037 0.002 2.182 0.226 0.056 0.003 7500.0 0.322 35.321 1.490 952.412 0.041 0.002 2.289 0.252 0.066 0.004 8000.0 0.320 34.817 1.579 952.169 0.045 0.003 2.391 0.279 0.076 0.004 8500.0 0.318 34.317 1.666 951.925 0.049 0.003 2.487 0.307 0.087 0.005 9000.0 0.317 33.822 1.753 951.682 0.053 0.004 2.579 0.335 0.099 0.007 9500.0 0.315 33.331 1.839 951.439 0.057 0.004 2.665 0.363 0.111 0.008 10000.0 0.313 32.845 1.924 951.196 0.061 0.005 2.747 0.392 0.123 0.009 10500.0 0.312 32.362 2.007 950.954 0.065 0.005 2.824 0.421 0.136 0.011 11000.0 0.310 31.883 2.090 950.712 0.070 0.006 2.897 0.451 0.150 0.013 11500.0 0.308 31.409 2.172 950.471 0.074 0.006 2.966 0.481 0.163 0.014 12000.0 0.307 30.938 2.252 950.230 0.079 0.007 3.030 0.511 0.177 0.017 12500.0 0.305 30.471 2.332 949.990 0.083 0.008 3.090 0.542 0.191 0.019 13000.0 0.303 30.007 2.411 949.750 0.088 0.009 3.147 0.572 0.205 0.021 13500.0 0.302 29.547 2.489 949.511 0.092 0.009 3.200 0.603 0.220 0.024 14000.0 0.300 29.090 2.566 949.273 0.097 0.010 3.249 0.634 0.234 0.026 14500.0 0.298 28.636 2.642 949.035 0.102 0.011 3.295 0.665 0.249 0.029 15000.0 0.297 28.185 2.717 948.798 0.107 0.012 3.338 0.697 0.264 0.032 15500.0 0.295 27.737 2.792 948.561 0.112 0.013 3.377 0.728 0.278 0.036 16000.0 0.294 27.293 2.866 948.325 0.117 0.014 3.414 0.759 0.293 0.039 16500.0 0.292 26.851 2.939 948.088 0.121 0.015 3.448 0.791 0.308 0.043 17000.0 0.291 26.412 3.011 947.851 0.126 0.016 3.480 0.822 0.322 0.046 17500.0 0.289 25.977 3.083 947.614 0.131 0.017 3.510 0.853 0.337 0.050 18000.0 0.288 25.545 3.153 947.375 0.137 0.018 3.538 0.885 0.352 0.054 18500.0 0.286 25.116 3.223 947.136 0.142 0.019 3.564 0.916 0.367 0.059 19000.0 0.284 24.690 3.292 946.896 0.147 0.021 3.588 0.947 0.382 0.063 20000.0 0.281 23.849 3.429 946.411 0.157 0.023 3.632 1.009 0.412 0.073 22500.0 0.273 21.804 3.756 945.174 0.185 0.031 3.718 1.161 0.487 0.101 25000.0 0.266 19.844 4.063 943.899 0.214 0.040 3.773 1.310 0.561 0.135 27500.0 0.258 17.969 4.352 942.583 0.244 0.050 3.801 1.454 0.632 0.174 30000.0 0.250 16.181 4.622 941.224 0.275 0.062 3.807 1.593 0.697 0.220 32500.0 0.242 14.481 4.871 939.817 0.307 0.076 3.794 1.725 0.757 0.272 35000.0 0.234 12.872 5.101 938.359 0.339 0.091 3.765 1.851 0.811 0.330 37500.0 0.226 11.357 5.311 936.845 0.372 0.108 3.723 1.969 0.858 0.394 40000.0 0.217 9.938 5.500 935.271 0.405 0.127 3.672 2.079 0.899 0.464 42500.0 0.209 8.620 5.668 933.633 0.437 0.146 3.613 2.180 0.933 0.540 45000.0 0.201 7.403 5.815 931.926 0.469 0.167 3.550 2.272 0.961 0.622 47500.0 0.193 6.293 5.939 930.145 0.500 0.189 3.485 2.354 0.982 0.710 50000.0 0.184 5.290 6.042 928.288 0.530 0.211 3.419 2.426 0.998 0.803 52500.0 0.176 4.396 6.123 926.351 0.559 0.233 3.354 2.488 1.009 0.900 55000.0 0.168 3.610 6.182 924.333 0.586 0.255 3.293 2.540 1.016 1.002 57500.0 0.159 2.930 6.220 922.235 0.610 0.277 3.236 2.583 1.019 1.108 60000.0 0.151 2.350 6.239 920.058 0.633 0.297 3.184 2.617 1.019 1.216 62500.0 0.143 1.865 6.239 917.808 0.653 0.317 3.137 2.643 1.017 1.326 65000.0 0.136 1.466 6.223 915.490 0.672 0.335 3.097 2.662 1.013 1.436 67500.0 0.128 1.142 6.193 913.112 0.687 0.351 3.062 2.675 1.009 1.547 70000.0 0.121 0.883 6.150 910.682 0.700 0.365 3.032 2.684 1.004 1.657 AREVA NP Inc.
controlled Uocument Kh Inlor FIueI Design Renrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-9 Table C.8 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 43.563 0.000 956.089 0.000 0.000 0.000 0.000 0.000 0.000 0.0 0.349 43.443 0.023 956.033 0.000 0.000 0.020 0.000 0.000 0.000 100.0 0.348 500.0 0.346 42.967 0.114 955.808 0.002 0.000 0.200 0.002 0.000 0.000 1000.0 0.344 42.381 0.226 955.527 0.004 0.000 0.432 0.007 0.000 0.000 1500.0 0.342 41.803 0.336 955.246 0.006 0.000 0.653 0.016 0.001 0.000 2000.0 0.340 41.234 0.445 954.965 0.009 0.000 0.863 0.028 0.003 0.000 2500.0 0.338 40.674 0.551 954.684 0.011 0.000 1.063 0.042 0.005 0.000 3000.0 0.336 40.120 0.656 954.404 0.014 0.000 1.253 0.059 0.008 0.000 3500.0 0.334 39.574 0.759 954.124 0.018 0.001 1.434 0.078 0.013 0.000 4000.0 0.332 39.035 0.860 953.844 0.021 0.001 1.607 0.098 0.018 0.000 4500.0 0.330 38.503 0.960 953.565 0.025 0.001 1.771 0.120 0.025 0.001 5000.0 0.328 37.977 1.058 953.286 0.028 0.001 1.928 0.143 0.032 0.001 5500.0 0.326 37.458 1.155 953.007 0.032 0.002 2.078 0.168 0.040 0.002 6000.0 0.324 36.944 1.250 952.728 0.036 0.002 2.220 0.193 0.050 0.002 6500.0 0.322 36.436 1.344 952.450 0.040 0.002 2.355 0.220 0.060 0.003 7000.0 0.320 35.934 1.437 952.172 0.045 0.003 2.484 0.247 0.071 0.003 7500.0 0.318 35.437 1.528 951.894 0.049 0.003 2.607 0.275 0.083 0.004 8000.0 0.317 34.945 1.618 951.617 0.054 0.004 2.723 0.303 0.096 0.005 8500.0 0.315 34.459 1.707 951.341 0.058 0.004 2.834 0.333 0.109 0.007 9000.0 0.313 33.977 1.794 951.064 0.063 0.005 2.939 0.362 0.123 0.008 9500.0 0.311 33.500 1.881 950.789 0.068 0.006 3.039 0.393 0.138 0.009 10000.0 0.309 33.028 1.966 950.513 0.073 0.006 3.134 0.423 0.153 0.011 10500.0 0.307 32.560 2.050 950.238 0.078 0.007 3.224 0.454 0.168 0.013 11000.0 0.305 32.097 2.132 949.964 0.083 0.008 3.308 0.486 0.184 0.015 11500.0 0.304 31.637 2.214 949.690 0.089 0.009 3.388 0.518 0.201 0.017 12000.0 0.302 31.182 2.295 949.417 0.094 0.010 3.464 0.550 0.217 0.019 12500.0 0.300 30.731 2.374 949.145 0.100 0.010 3.535 0.582 0.234 0.022 13000.0 0.298 30.284 2.453 948.873 0.105 0.011 3.602 0.614 0.251 0.025 13500.0 0.297 29.840 2.531 948.602 0.111 0.012 3.665 0.647 0.268 0.028 14000.0 0.295 29.401 2.607 948.332 0.116 0.014 3.724 0.680 0.285 0.031 14500.0 0.293 28.964 2.683 948.062 0.122 0.015 3.780 0.713 0.303 0.034 15000.0 0.291 28.531 2.758 947.793 0.128 0.016 3.831 0.746 0.320 0.037 15500.0 0.290 28.101 2.832 947.525 0.133 0.017 3.879 0.779 0.337 0.041 16000.0 0.288 27.675 2.905 947.257 0.139 0.018 3.924 0.812 0.355 0.045 16500.0 0.286 27.252 2.977 946.990 0.145 0.020 3.966 0.845 0.372 0.049 17000.0 0.285 26.832 3.048 946.723 0.151 0.021 4.005 0.879 0.389 0.053 17500.0 0.283 26.415 3.119 946.455 0.157 0.023 4.041 0.912 0.407 0.058 18000.0 0.281 26.001 3.188 946.188 0.162 0.024 4.076 0.945 0.424 0.062 18500.0 0.280 25.591 3.257 945.919 0.168 0.026 4.108 0.978 0.441 0.067 19000.0 0.278 25.184 3.325 945.650 0.174 0.027 4.138 1.010 0.458 0.072 19500.0 0.276 24.780 3.392 945.380 0.181 0.029 4.166 1.043 0.476 0.077 20000.0 0.275 24.380 3.459 945.109 0.187 0.031 4.193 1.076 0.493 0.083 20500.0 0.273 23.983 3.524 944.837 0.193 0.032 4.218 1.108 0.510 0.088 22500.0 0.266 22.429 3.779 943.733 0.218 0.040 4.305 1.236 0.579 0.113 25000.0 0.258 20.562 4.078 942.323 0.252 0.052 4.383 1.392 0.664 0.149 27500.0 0.250 18.780 4.359 940.876 0.286 0.065 4.433 1.542 0.745 0.190 30000.0 0.242 17.082 4.619 939.390 0.321 0.080 4.458 1.687 0.821 0.237 32500.0 0.234 15.470 4.860 937.863 0.357 0.097 4.462 1.826 0.892 0.289 35000.0 0.226 13.942 5.081 936.292 0.392 0.116 4.448 1.957 0.956 0.347 37500.0 0.218 12.500 5.283 934.676 0.428 0.136 4.420 2.081 1.013 0.410 40000.0 0.210 11.146 5.465 933.012 0.464 0.158 4.379 2.197 1.063 0.478 42500.0 0.202 9.878 5.628 931.297 0.499 0.182 4.329 2.304 1.107 0.551 45000.0 0.194 8.699 5.772 929.528 0.533 0.207 4.272 2.402 1.143 0.629 47500.0 0.187 7.609 5.896 927.704 0.567 0.233 4.209 2.491 1.173 0.711 50000.0 0.179 6.608 6.001 925.822 0.599 0.259 4.144 2.571 1.197 0.797 52500.0 0.171 5.696 6.087 923.881 0.629 0.286 4.078 2.641 1.216 0.886 55000.0 0.164 4.873 6.154 921.879 0.659 0.313 4.011 2.702 1.229 0.979 57500.0 0.157 4.137 6.202 919.817 0.686 0.340 3.947 2.754 1.237 1.075 60000.0 0.149 3.485 6.233 917.696 0.711 0.366 3.885 2.798 1.242 1.172 62500.0 0.142 2.913 6.248 915.515 0.734 0.391 3.827 2.834 1.244 1.272 65000.0 0.135 2.418 6.247 913.279 0.755 0.415 3.773 2.862 1.242 1.372 67500.0 0.129 1.993 6.233 910.991 0.774 0.437 3.724 2.884 1.239 1.473 70000.0 0.122 1.632 6.205 908.654 0.790 0.458 3.680 2.900 1.235 1.573 AREVA NP Inc.
Uontroiled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-10 Table C.9 [ JExposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.563 0.000 956.089 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.348 43.444 0.024 956.023 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.346 42.971 0.120 955.758 0.002 0.000 0.233 0.002 0.000 0.000 1000.0 0.344 42.390 0.238 955.427 0.005 0.000 0.503 0.008 0.000 0.000 1500.0 0.341 41.819 0.353 955.097 0.008 0.000 0.760 0.018 0.002 0.000 2000.0 0.339 41.257 0.466 954.767 0.011 0.000 1.005 0.031 0.004 0.000 2500.0 0.336 40.705 0.577 954.438 0.014 0.000 1.238 0.048 0.007 0.000 3000.0 0.334 40.161 0.686 954.109 0.018 0.001 1.460 0.066 0.011 0.000 3500.0 0.332 39.626 0.793 953.780 0.022 0.001 1.673 0.086 0.017 0.000 4000.0 0.329 39.098 0.898 953.452 0.026 0.001 1.875 0.109 0.024 0.001 4500.0 0.327 38.577 1.001 953.125 0.031 0.001 2.068 0.132 0.033 0.001 5000.0 0.325 38.064 1.103 952.797 0.035 0.002 2.253 0.157 0.042 0.001 5500.0 0.322 37.557 1.203 952.471 0.040 0.002 2.430 0.183 0.053 0.002 6000.0 0.320 37.058 1.301 952.144 0.045 0.003 2.598 0.211 0.065 0.003 6500.0 0.318 36.564 1.398 951.818 0.050 0.003 2.759 0.239 0.078 0.003 7000.0 0.316 36.077 1.493 951.493 0.056 0.004 2.913 0.268 0.092 0.004 7500.0 0.314 35.595 1.586 951.168 0.061 0.005 3.060 0.298 0.107 0.005 8000.0 0.311 35.119 1.678 950.844 0.067 0.005 3.201 0.328 0.122 0.007 8500.0 0.309 34.649 1.769 950.520 0.073 0.006 3.334 0.359 0.138 0.008 9000.0 0.307 34.184 1.858 950.197 0.079 0.007 3.462 0.391 0.156 0.009 9500.0 0.305 33.725 1.946 949.874 0.085 0.008 3.584 0.423 0.173 0.011 10000.0 0.303 33.270 2.032 949.551 0.092 0.009 3.701 0.456 0.191 0.013 10500.0 0.301 32.820 2.118 949.230 0.098 0.010 3.811 0.489 0.210 0.015 11000.0 0.299 32.375 2.202 948.909 0.104 0.011 3.917 0.522 0.229 0.017 11500.0 0.297 31.935 2.285 948.588 0.111 0.012 4.017 0.556 0.249 0.020 12000.0 0.295 31.500 2.366 948.268 0.117 0.014 4.113 0.590 0.268 0.022 12500.0 0.293 31.068 2.446 947.949 0.124 0.015 4.203 0.625 0.288 0.025 13000.0 0.291 30.641 2.526 947.630 0.131 0.017 4.289 0.659 0.309 0.028 13500.0 0.289 30.219 2.604 947.312 0.138 0.018 4.371 0.695 0.329 0.031 14000.0 0.287 29.800 2.681 946.995 0.145 0.020 4.448 0.730 0.349 0.035 14500.0 0.285 29.385 2.757 946.679 0.152 0.021 4.521 0.765 0.370 0.038 15000.0 0.283 28.974 2.831 946.363 0.159 0.023 4.590 0.801 0.391 0.042 15500.0 0.281 28.567 2.905 946.048 0.166 0.025 4.655 0.837 0.411 0.046 16000.0 0.279 28.163 2.978 945.734 0.173 0.027 4.717 0.872 0.432 0.050 16500.0 0.277 27.763 3.050 945.420 0.180 0.029 4.774 0.908 0.452 0.055 17000.0 0.276 27.366 3.120 945.107 0.187 0.031 4.829 0.944 0.473 0.059 17500.0 0.274 26.972 3.190 944.794 0.194 0.033 4.880 0.980 0.493 0.064 18000.0 0.272 26.583 3.259 944.482 0.201 0.035 4.929 1.016 0.514 0.069 18500.0 0.270 26.196 3.327 944.169 0.209 0.037 4.974 1.052 0.534 0.074 19000.0 0.268 25.813 3.394 943.856 0.216 0.039 5.018 1.088 0.554 0.079 19500.0 0.266 25.433 3.460 943.543 0.223 0.042 5.059 1.124 0.574 0.085 20000.0 0.265 25.056 3.526 943.230 0.231 0.044 5.097 1.159 0.595 0.090 20500.0 0.263 24.683 3.590 942.915 0.238 0.047 5.134 1.195 0.615 0.096 21000.0 0.261 24.313 3.654 942.600 0.245 0.049 5.169 1.230 0.635 0.102 21500.0 0.259 23.946 3.716 942.283 0.253 0.052 5.203 1.265 0.655 0.108 22000.0 0.258 23.583 3.778 941.966 0.260 0.055 5.234 1.300 0.675 0.115 22500.0 0.256 23.223 3.839 941.647 0.268 0.057 5.265 1.335 0.695 0.122 23000.0 0.254 22.867 3.900 941.328 0.275 0.060 5.293 1.370 0.714 0.128 25000.0 0.247 21.475 4.132 940.035 0.306 0.073 5.395 1.507 0.793 0.157 27500.0 0.239 19.809 4.405 938.390 0.345 0.091 5.494 1.673 0.889 0.198 30000.0 0.230 18.226 4.658 936.712 0.385 0.111 5.566 1.833 0.981 0.244 32500.0 0.222 16.723 4.891 934.998 0.424 0.133 5.613 1.987 1.067 0.294 35000.0 0.214 15.300 5.104 933.250 0.464 0.158 5.640 2.135 1.148 0.348 37500.0 0.206 13.955 5.298 931.464 0.504 0.184 5.649 2.275 1.222 0.407 40000.0 0.198 12.688 5.474 929.642 0.543 0.213 5.643 2.408 1.290 0.469 42500.0 0.191 11.498 5.631 927.781 0.581 0.243 5.624 2.533 1.352 0.535 45000.0 0.183 10.384 5.769 925.881 0.619 0.275 5.594 2.650 1.407 0.605 47500.0 0.176 9.344 5.890 923.942 0.655 0.309 5.556 2.759 1.456 0.678 50000.0 0.169 8.377 5.994 921.963 0.690 0.343 5.511 2.859 1.498 0.754 52500.0 0.162 7.482 6.081 919.943 0.724 0.378 5.461 2.951 1.535 0.832 55000.0 0.156 6.656 6.153 917.883 0.756 0.414 5.407 3.035 1.566 0.913 57500.0 0.149 5.899 6.208 915.784 0.786 0.449 5.351 3.110 1.592 0.997 60000.0 0.143 5.208 6.249 913.645 0.814 0.485 5.294 3.177 1.613 1.082 62500.0 0.137 4.580 6.275 911.468 0.840 0.520 5.237 3.236 1.630 1.169 65000.0 0.131 4.013 6.288 909.253 0.865 0.555 5.181 3.288 1.643 1.257 67500.0 0.126 3.503 6.289 907.003 0.887 0.588 5.127 3.333 1.653 1.346 70000.0 0.120 3.047 6.278 904.718 0.906 0.620 5.074 3.371 1.660 1.436 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-11 Table C.10 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.578 0.000 956.074 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.348 43.458 0.022 956.026 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.347 42.980 0.109 955.834 0.001 0.000 0.172 0.001 0.000 0.000 1000.0 0.345 42.390 0.217 955.594 0.003 0.000 0.371 0.006 0.000 0.000 1500.0 0.343 41.807 0.323 955.355 0.005 0.000 0.561 0.014 0.001 0.000 2000.0 0.341 41.232 0.428 955.115 0.007 0.000 0.741 0.024 0.002 0.000 2500.0 0.340 40.665 0.531 954.876 0.009 0.000 0.912 0.037 0.004 0.000 3000.0 0.338 40.103 0.632 954.637 0.012 0.000 1.075 0.052 0.006 0.000 3500.0 0.336 39.548 0.733 954.399 0.014 0.000 1.230 0.068 0.009 0.000 4000.0 0.334 38.999 0.831 954.161 0.017 0.001 1.378 0.087 0.013 0.000 4500.0 0.333 38.456 0.928 953.923 0.020 0.001 1.518 0.106 0.018 0.001 5000.0 0.331 37.918 1.024 953.686 0.023 0.001 1.651 0.127 0.024 0.001 5500.0 0.329 37.386 1.119 953.449 0.026 0.001 1.777 0.149 0.030 0.001 6000.0 0.327 36.859 1.213 953.213 0.029 0.001 1.897 0.173 0.037 0.002 6500.0 0.326 36.337 1.305 952.977 0.032 0.002 2.011 0.197 0.045 0.002 7000.0 0.324 35.820 1.396 952.742 0.036 0.002 2.119 0.222 0.053 0.003 7500.0 0.322 35.307 1.486 952.508 0.039 0.002 2.221 0.247 0.062 0.003 8000.0 0.321 34.799 1.575 952.274 0.043 0.003 2.318 0.273 0.072 0.004 8500.0 0.319 34.295 1.663 952.041 0.047 0.003 2.410 0.300 0.082 0.005 9000.0 0.317 33.796 1.750 951.808 0.050 0.003 2.497 0.328 0.093 0.006 9500.0 0.316 33.300 1.836 951.577 0.054 0.004 2.578 0.356 0.104 0.007 10000.0 0.314 32.808 1.920 951.346 0.058 0.004 2.655 0.384 0.116 0.009 10500.0 0.313 32.320 2.004 951.115 0.062 0.005 2.728 0.412 0.128 0.010 11000.0 0.311 31.835 2.087 950.886 0.066 0.005 2.797 0.441 0.140 0.012 11500.0 0.309 31.354 2.169 950.657 0.070 0.006 2.861 0.471 0.153 0.013 12000.0 0.308 30.877 2.250 950.428 0.075 0.007 2.922 0.500 0.166 0.015 12500.0 0.306 30.403 2.330 950.200 0.079 0.007 2.979 0.530 0.179 0.017 13000.0 0.305 29.932 2.409 949.971 0.083 0.008 3.033 0.559 0.192 0.019 13500.0 0.303 29.465 2.488 949.742 0.088 0.009 3.084 0.589 0.206 0.022 14000.0 0.301 29.002 2.565 949.513 0.092 0.009 3.133 0.619 0.220 0.024 14500.0 0.300 28.541 2.642 949.282 0.097 0.010 3.179 0.650 0.234 0.027 15000.0 0.298 28.085 2.718 949.051 0.101 0.011 3.222 0.680 0.248 0.030 15500.0 0.297 27.631 2.793 948.819 0.106 0.012 3.264 0.710 0.262 0.033 17500.0 0.290 25.854 3.085 947.878 0.126 0.016 3.409 0.832 0.321 0.047 20000.0 0.283 23.711 3.433 946.671 0.152 0.022 3.550 0.984 0.398 0.069 22500.0 0.275 21.656 3.762 945.429 0.180 0.029 3.651 1.135 0.474 0.096 25000.0 0.267 19.688 4.070 944.149 0.210 0.038 3.718 1.283 0.548 0.129 27500.0 0.259 17.808 4.360 942.827 0.240 0.049 3.756 1.428 0.619 0.169 30000.0 0.251 16.017 4.629 941.461 0.272 0.061 3.770 1.568 0.685 0.214 32500.0 0.243 14.317 4.879 940.048 0.304 0.074 3.763 1.702 0.745 0.265 35000.0 0.234 12.709 5.108 938.582 0.337 0.090 3.739 1.830 0.800 0.323 37500.0 0.226 11.197 5.317 937.060 0.370 0.107 3.701 1.950 0.848 0.387 40000.0 0.218 9.783 5.504 935.477 0.403 0.125 3.652 2.062 0.889 0.457 42500.0 0.210 8.471 5.671 933.828 0.435 0.145 3.596 2.165 0.924 0.533 45000.0 0.201 7.263 5.815 932.110 0.468 0.166 3.535 2.258 0.952 0.615 47500.0 0.193 6.163 5.938 930.318 0.499 0.187 3.471 2.342 0.974 0.703 50000.0 0.185 5.171 6.038 928.448 0.529 0.210 3.406 2.416 0.991 0.797 52500.0 0.176 4.288 6.117 926.498 0.558 0.232 3.343 2.479 1.003 0.895 55000.0 0.168 3.515 6.173 924.467 0.584 0.254 3.283 2.532 1.010 0.997 57500.0 0.159 2.847 6.209 922.355 0.609 0.276 3.227 2.576 1.013 1.103 60000.0 0.151 2.280 6.225 920.166 0.632 0.297 3.176 2.611 1.014 1.211 62500.0 0.143 1.806 6.224 917.904 0.652 0.316 3.131 2.638 1.012 1.321 65000.0 0.135 1.417 6.206 915.575 0.670 0.334 3.091 2.658 1.010 1.432 67500.0 0.128 1.103 6.174 913.187 0.686 0.350 3.057 2.672 1.006 1.543 70000.0 0.121 0.852 6.130 910.748 0.699 0.364 3.028 2.681 1.001 1.653 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-12 Table C.ll [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.578 0.000 956.074 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.348 43.458 0.023 956.019 0.000 0.000 0.019 0.000 0.000 0.000 500.0 0.347 42.982 0.114 955.799 0.002 0.000 0.196 0.002 0.000 0.000 1000.0 0.345 42.395 0.225 955.525 0.004 0.000 0.422 0.007 0.000 0.000 1500.0 0.342 41.816 0.335 955.251 0.006 0.000 0.637 0.016 0.001 0.000 2000.0 0.340 41.246 0.443 954.978 0.008 0.000 0.841 0.027 0.003 0.000 2500.0 0.338 40.684 0.549 954.705 0.011 0.000 1.036 0.041 0.005 0.000 3000.0 0.336 40.130 0.653 954.433 0.014 0.000 1.220 0.058 0.008 0.000 3500.0 0.334 39.582 0.756 954.161 0.017 0.001 1.396 0.076 0.012 0.000 4000.0 0.333 39.041 0.857 953.890 0.020 0.001 1.563 0.096 0.017 0.000 4500.0 0.331 38.507 0.956 953.619 0.024 0.001 1.722 0.118 0.023 0.001 5000.0 0.329 37.978 1.054 953.349 0.027 0.001 1.873 0.141 0.030 0.001 5500.0 0.327 37.456 1.151 953.080 0.031 0.002 2.016 0.165 0.039 0.001 6000.0 0.325 36.940 1.246 952.811 0.035 0.002 2.153 0.190 0.047 0.002 6500.0 0.323 36.429 1.340 952.543 0.039 0.002 2.282 0.216 0.057 0.003 7000.0 0.321 35.923 1.432 952.276 0.043 0.003 2.406 0.243 0.068 0.003 7500.0 0.319 35.422 1.523 952.009 0.047 0.003 2.522 0.270 0.079 0.004 8000.0 0.317 34.927 1.613 951.743 0.051 0.003 2.633 0.298 0.091 0.005 8500.0 0.316 34.436 1.702 951.478 0.056 0.004 2.738 0.327 0.104 0.006 9000.0 0.314 33.950 1.789 951.214 0.060 0.005 2.838 0.356 0.117 0.007 9500.0 0.312 33.468 1.875 950.951 0.065 0.005 2.932 0.386 0.130 0.009 10000.0 0.310 32.990 1.961 950.688 0.070 0.006 3.021 0.416 0.144 0.010 10500.0 0.308 32.517 2.044 950.426 0.075 0.006 3.105 0.446 0.159 0.012 11000.0 0.307 32.047 2.127 950.166 0.079 0.007 3.185 0.477 0.174 0.014 11500.0 0.305 31.582 2.209 949.905 0.084 0.008 3.260 0.508 0.189 0.016 12000.0 0.303 31.120 2.290 949.646 0.090 0.009 3.331 0.539 0.204 0.018 12500.0 0.301 30.662 2.370 949.386 0.095 0.010 3.398 0.571 0.220 0.020 13000.0 0.300 30.208 2.449 949.127 0.100 0.011 3.461 0.603 0.236 0.023 13500.0 0.298 29.757 2.527 948.868 0.105 0.011 3.521 0.634 0.252 0.026 14000.0 0.296 29.310 2.604 948.609 0.111 0.012 3.578 0.666 0.268 0.029 14500.0 0.295 28.867 2.680 948.349 0.116 0.014 3.632 0.698 0.285 0.032 15000.0 0.293 28.427 2.755 948.088 0.121 0.015 3.684 0.730 0.301 0.035 15500.0 0.291 27.991 2.830 947.827 0.127 0.016 3.733 0.762 0.318 0.038 16000.0 0.290 27.558 2.903 947.565 0.133 0.017 3.779 0.794 0.335 0.042 16500.0 0.288 27.129 2.976 947.301 0.13a 0.018 3.823 0.826 0.352 0.046 17500.0 0.285 26.282 3.119 946.771 0.150 0.021 3.906 0.891 0.387 0.054 20000.0 0.276 24.229 3.461 945.423 0.180 0.029 4.079 1.050 0.475 0.078 22500.0 0.268 22.264 3.783 944.041 0.213 0.038 4.209 1.208 0.562 0.108 25000.0 0.260 20.388 4.084 942.624 0.246 0.050 4.303 1.362 0.648 0.143 27500.0 0.251 18.600 4.365 941.171 0.281 0.063 4.365 1.513 0.729 0.184 30000.0 0.243 16.898 4.625 939.678 0.317 0.078 4.401 1.659 0.806 0.230 32500.0 0.235 15.283 4.866 938.143 0.353 0.095 4.413 1.798 0.876 0.282 35000.0 0.227 13.756 5.087 936.565 0.389 0.113 4.406 1.931 0.941 0.340 37500.0 0.219 12.316 5.288 934.940 0.425 0.134 4.383 2.057 0.999 0.403 40000.0 0.211 10.965 5.469 933.266 0.461 0.156 4.347 2.174 1.049 0.471 42500.0 0.203 9.703 5.630 931.541 0.496 0.180 4.300 2.283 1.094 0.544 45000.0 0.195 8.531 5.772 929.762 0.531 0.205 4.246 2.384 1.131 0.621 47500.0 0.187 7.449 5.894 927.926 0.565 0.231 4.186 2.474 1.162 0.704 50000.0 0.179 6.458 5.997 926.032 0.597 0.257 4.122 2.556 1.186 0.790 52500.0 0.172 5.557 6.080 924.079 0.628 0.285 4.058 2.628 1.205 0.880 55000.0 0.164 4.745 6.145 922.064 0.657 0.312 3.993 2.690 1.219 0.973 57500.0 0.157 4.021 6.191 919.989 0.684 0.339 3.930 2.744 1.228 1.069 60000.0 0.149 3.381 6.220 917.854 0.709 0.365 3.870 2.789 1.234 1.167 62500.0 0.142 2.821 6.232 915.661 0.733 0.390 3.814 2.826 1.236 1.266 65000.0 0.135 2.337 6.229 913.412 0.754 0.414 3.761 2.855 1.235 1.367 67500.0 0.129 1.923 6.212 911.112 0.772 0.436 3.714 2.877 1.233 1.468 70000.0 0.122 1.573 6.183 908.764 0.788 0.457 3.671 2.894 1.229 1.569 AREVA NP Inc.
uontroiied uocument Kh i-"lnr Fiue Desinn Pannrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-13 Table C.12 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 956.074 0.000 0.0 0.349 43.578 0.000 956.010 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.348 43.459 0.024 0.000 0.023 0.000 0.000 0.000 500.0 0.346 42.986 0.119 955.751 0.002 0.000 0.228 0.002 0.000 0.000 1000.0 0.344 42.404 0.236 955.429 0.005 0.000 0.490 0. 008 0.000 0.000 1500.0 0.341 41.832 0.351 955.107 0.007 0.000 0. 740 0.018 0.002 0.000 2000.0 0.339 41 .269 0.464 954.786 0.010 0.000 0.978 0.031 0.004 0.000 2500.0 0.337 40.716 0.574 954.466 0.014 0.000 1.204 0.047 0.007 0.000 3000.0 0.334 40.171 0.682 954.147 0.017 0.001 1.419 0.065 0.011 0.000 3500.0 0.332 39.633 0.789 953.828 0.021 0.001 1.624 0.085 0.017 0.000 4000.0 0.330 39.104 0.894 953.510 0.025 0.001 1.819 0.107 0.023 0.001 4500.0 0.328 38.581 0. 996 953.193 0.029 0.001 2.006 0.131 0.031 0.001 5000.0 0.325 38.066 1.098 952.877 0.034 0.002 2.183 0.155 0.041 0.001 5500.0 0.323 37.557 1.197 952.561 0.039 0.002 2.352 0.181 0.051 0.002 6000.0 0.321 37.054 1.295 952.246 0.043 0.003 2.514 0.208 0.062 0.002 6500.0 0.319 36.558 1.391 951.932 0.048 0.003 2.667 0.236 0.075 0.003 7000.0 0.317 36.067 1.486 951.618 0.054 0.004 2.814 0.265 0.088 0.004 7500.0 0.315 35.582 1.579 951.306 0.059 0.004 2.954 0.294 0.102 0.005 8000.0 0.312 35.103 1.671 950.994 0.065 0.005 3.087 0. 324 0.117 0.006 8500.0 0.310 34.629 1.761 950.683 0.070 0.006 3.214 0.355 0.132 0.007 9000.0 0.308 34.160 1.850 950.372 0.076 0.007 3.334 0.386 0.149 0.009 9500.0 0.306 33.695 1.938 950.063 0.082 0.008 3.449 0.418 0.165 0.011 10000.0 0.304 33.236 2.024 949.755 0.088 0.008 3.558 0.450 0.182 0.012 10500.0 0.302 32.781 2.109 949.447 0.094 0.009 3.662 0.483 0.200 0.014 11000.0 0.300 32.331 2.193 949.140 0.100 0.011 3.761 0.516 0.218 0.016 11500.0 0.298 31.885 2.276 948.834 0.106 0.012 3.855 0.549 0.236 0.019 12000.0 0.296 31.443 2. 357 948.529 0.112 0.013 3.944 0.583 0.255 0.021 12500.0 0.294 31.005 2.438 948.224 0.119 0.014 4.028 0.617 0.273 0.024 13000.0 0.292 30.571 2.517 947.920 0.125 0.015 4.109 0.651 0.292 0.027 13500.0 0.291 30.142 2.596 947.616 0.132 0.017 4.186 0.685 0.312 0.030 14000.0 0.289 29.716 2.673 947.313 0.138 0.018 4.259 0.719 0.331 0.033 14500.0 0.287 29.294 2.749 947.009 0.145 0.020 4.329 0.754 0.350 0.036 15000.0 0.285 28.876 2.824 946.704 0.151 0.021 4.395 0.788 0.370 0.040 15500.0 0.283 28.461 2.898 946.400 0.158 0.023 4.459 0.823 0.390 0.044 16000.0 0.281 28.051 2.972 946.095 0.165 0.025 4.520 0.857 0.409 0.048 16500.0 0.279 27.644 3.044 945.789 0.172 0.026 4.578 0.892 0.429 0.052 17000.0 0.277 27.241 3.115 945.482 0.179 0.028 4.634 0.927 0.449 0.056 17500.0 0.276 26.841 3.186 945.174 0.186 0.030 4.687 0.962 0.469 0.061 18000.0 0.274 26.446 3.255 944.865 0.193 0.032 4.739 0.996 0.490 0.065 18500.0 0.272 26.054 3.324 944.555 0.201 0.034 4.788 1.031 0.510 0.070 19000.0 0.270 25.666 3.391 944.244 0.208 0.037 4.835 1.066 0.530 0.075 20000.0 0.267 24.900 3.524 943.618 0.223 0.041 4.923 1.135 0.571 0.086 22500.0 0.258 23.050 3.840 942.031 0.260 0.054 5.114 1.306 0.672 0.117 25000.0 0.249 21.289 4.135 940.412 0.299 0.070 5.264 1.475 0.772 0.152 27500.0 0.240 19.614 4.408 938.760 0.339 0.088 5.380 1.639 0.869 0.192 30000.0 0.232 18.024 4.661 937.074 0.379 0.108 5.466 1.799 0.961 0.238 32500.0 0.223 16.517 4.894 935.352 0.419 0.130 5.526 1.954 1.047 0.287 35000.0 0.215 15.092 5.107 933.595 0.459 0.154 5.563 2.102 1.128 0.341 37500.0 0.207 13.747 5.301 931.801 0.499 0.181 5.580 2.244 1.203 0.400 40000.0 0.199 12.482 5.475 929.969 0.539 0.209 5.581 2.378 1.271 0.462 42500.0 0.192 11.295 5.631 928.099 0.577 0.240 5.568 2.505 1.333 0.528 45000.0 0.184 10.186 5.768 926.189 0.615 0.272 5.543 2.624 1.388 0.598 47500.0 0.177 9.152 5.887 924.239 0.652 0.305 5.509 2.734 1.438 0.671 50000.0 0.170 8.192 5.989 922.248 0.687 0.340 5.467 2.836 1.481 0.747 52500.0 0.163 7.306 6.074 920.217 0.721 0.375 5.420 2.930 1.518 0.826 55000.0 0.156 6.489 6.143 918.146 0.753 0.411 5.369 3.015 1.550 0.907 57500.0 0.149 5.742 6.196 916.034 0.784 0.446 5.316 3.091 1.576 0.990 60000.0 0.143 5.061 6.234 913.883 0.812 0.482 5.261 3.160 1.598 1.076 62500.0 0.137 4.443 6.258 911.693 0.838 0.517 5.207 3.220 1.616 1.163 65000.0 0.131 3.887 6.269 909.466 0.862 0.552 5.153 3.273 1.629 1.251 67500.0 0.126 3.387 6.267 907.204 0.884 0.585 5.100 3.319 1.640 1.341 70000.0 0.120 2.942 6.254 904.907 0.904 0.617 5.049 3.358 1.647 1.431 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-14 Table C.13 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.146 0.000 956.506 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.345 43.029 0.022 956.454 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.343 42.552 0.112 956.241 0.002 0.000 0.195 0.002 0.000 0.000 1000.0 0.341 41.965 0.221 955.976 0.003 0.000 0.415 0.007 0.000 0.000 1500.0 0.339 41.386 0.329 955.710 0.006 0.000 0.624 0.016 0.001 0.000 2000.0 0.337 40.816 0.435 955.444 0.008 0.000 0.823 0.027 0.002 0.000 2500.0 0.335 40.253 0.540 955.177 0.010 0.000 1.012 0.042 0.005 0.000 3000.0 0.334 39.698 0.643 954.911 0.013 0.000 1.193 0.058 0.008 0.000 3500.0 0.332 39.150 0.744 954.644 0.016 0.001 1.365 0.077 0.012 0.000 4000.0 0.330 38.609 0.843 954.377 0.019 0.001 1.529 0.097 0.017 0.000 4500.0 0.328 38.075 0.942 954.110 0.022 0.001 1.686 0.118 0.023 0.001 5000.0 0.326 37.547 1.038 953.843 0.026 0.001 1.835 0.141 0.029 0.001 5500.0 0.324 37.025 1.134 953.576 0.029 0.001 1.978 0.165 0.037 0.001 6000.0 0.322 36.509 1.228 953.309 0.033 0.002 2.113 0.191 0.046 0.002 6500.0 0.320 35.999 1.321 953.041 0.037 0.002 2.243 0.217 0.056 0.003 7000.0 0.319 35.494 1.412 952.773 0.041 0.002 2.366 0.244 0.066 0.003 7500.0 0.317 34.994 1.503 952.505 0.045 0.003 2.484 0.271 0.077 0.004 8000.0 0.315 34.500 1.592 952.237 0.049 0.003 2.596 0.300 0.089 0.005 8500.0 0.313 34.011 1.679 951.969 0.054 0.004 2.703 0.329 0.102 0.007 9000.0 0.311 33.527 1.766 951.701 0.058 0.004 2.804 0.358 0.115 0.008 9500.0 0.310 33.048 1.852 951.433 0.063 0.005 2.901 0.388 0.129 0.009 10000.0 0.308 32.573 1.936 951.165 0.067 0.006 2.992 0.419 0.143 0.011 10500.0 0.306 32.103 2.019 950.897 0.072 0.006 3.080 0.449 0.158 0.013 11000.0 0.304 31.637 2.101 950.629 0.077 0.007 3.162 0.480 0.173 0.015 11500.0 0.302 31.176 2.183 950.361 0.082 0.008 3.241 0.512 0.189 0.017 12000.0 0.301 30.719 2.263 950.093 0.087 0.009 3.315 0.543 0.205 0.020 12500.0 0.299 30.266 2.342 949.825 0.093 0.009 3.385 0.575 0.221 0.022 13000.0 0.297 29.817 2.420 949.557 0.098 0.010 3.452 0.607 0.237 0.025 13500.0 0.295 29.372 2.497 949.289 0.103 0.011 3.514 0.640 0.254 0.028 14000.0 0.294 28.930 2.573 949.021 0.109 0.012 3.573 0.672 0.271 0.031 14500.0 0.292 28.493 2.648 948.754 0.114 0.013 3.629 0.705 0.288 0.034 15000.0 0.290 28.059 2.723 948.487 0.120 0.014 3.681 0.737 0.305 0.038 15500.0 0.289 27.628 2.796 948.220 0.125 0.016 3.730 0.770 0.322 0.042 16000.0 0.287 27.201 2.868 947.953 0.131 0.017 3.776 0.803 0.339 0.045 16500.0 0.285 26.778 2.940 947.687 0.137 0.018 3.818 0.835 0.356 0.050 17000.0 0.284 26.357 3.011 947.420 0.142 0.019 3.858 0.868 0.373 0.054 17500.0 0.282 25.940 3.081 947.153 0.148 0.021 3.896 0.901 0.390 0.058 18000.0 0.280 25.526 3.150 946.886 0.154 0.022 3.931 0.933 0.407 0.063 18500.0 0.279 25.116 3.218 946.618 0.160 0.024 3.964 0.966 0.424 0.068 19000.0 0.277 24.709 3.285 946.349 0.166 0.025 3.994 0.998 0.441 0.073 19500.0 0.275 24.306 3.352 946.080 0.172 0.027 4.023 1.031 0.458 0.079 20000.0 0.274 23.905 3.418 945.809 0.178 0.029 4.050 1.063 0.475 0.084 20500.0 0.272 23.509 3.483 945.537 0.184 0.030 4.076 1.095 0.491 0.090 21000.0 0.271 23.115 3.547 945.264 0.190 0.032 4.100 1.127 0.508 0.096 22500.0 0.266 21.957 3.735 944.436 0.209 0.038 4.163 1.222 0.559 0.116 25000.0 0.258 20.095 4.032 943.025 0.241 0.049 4.243 1.376 0.642 0.152 27500.0 0.249 18.321 4.309 941.576 0.275 0.062 4.294 1.524 0.721 0.195 30000.0 0.241 16.633 4.566 940.087 0.309 0.077 4.319 1.667 0.795 0.243 32500.0 0.233 15.033 4.803 938.554 0.344 0.094 4.324 1.803 0.864 0.297 35000.0 0.225 13.519 5.020 936.975 0.379 0.112 4.312 1.931 0.926 0.357 37500.0 0.217 12.094 5.218 935.349 0.415 0.132 4.284 2.052 0.981 0.422 40000.0 0.209 10.757 5.396 933.673 0.450 0.154 4.245 2.165 1.030 0.492 42500.0 0.202 9.509 5.555 931.943 0.485 0.177 4.197 2.269 1.072 0.568 45000.0 0.194 8.352 5.694 930.158 0.519 0.202 4.142 2.364 1.107 0.648 47500.0 0.186 7.285 5.813 928.316 0.552 0.228 4.082 2.450 1.136 0.732 50000.0 0.178 6.308 5.913 926.414 0.584 0.254 4.020 2.526 1.158 0.821 52500.0 0.171 5.422 5.994 924.451 0.615 0.280 3.957 2.593 1.176 0.912 55000.0 0.163 4.625 6.057 922.428 0.644 0.307 3.894 2.652 1.188 1.007 57500.0 0.156 3.914 6.101 920.343 0.671 0.333 3.834 2.701 1.196 1.105 60000.0 0.149 3.287 6.129 918.198 0.696 0.358 3.776 2.743 1.201 1.204 62500.0 0.142 2.740 6.140 915.994 0.718 0.382 3.722 2.776 1.202 1.305 65000.0 0.135 2.268 6.136 913.736 0.739 0.405 3.672 2.803 1.201 1.407 67500.0 0.129 1.864 6.119 911.425 0.757 0.426 3.627 2.823 1.199 1.509 70000.0 0.122 1.523 6.090 909.068 0.773 0.446 3.586 2.838 1.195 1.610 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-15 Table C.14 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43. 148 0.000 956.506 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.345 43.029 0.023 956.447 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.343 42.554 0. 116 956.206 0.002 0.000 0.220 0.002 0.000 0.000 1000.0 0.341 41.971 0.229 955.904 0.004 0.000 0.467 0.008 0.000 0.000 1500.0 0.339 41.396 0.341 955.603 0.007 0.000 0. 703 0.018 0.001 0.000 2000.0 0.336 40.831 0.450 955.302 0.009 0.000 0.927 0.031 0.003 0.000 2500.0 0.334 40.275 0.558 955.000 0.012 0.000 1.140 0.046 0.006 0.000 3000.0 0.332 39.727 0.663 954.699 0.016 0.000 1.343 0.064 0.010 0.000 3500.0 0.330 39.187 0.767 954.397 0.019 0.001 1.537 0.084 0.015 0.000 4000.0 0.328 38.654 0.869 954.096 0.023 0.001 1.723 0.106 0.021 0.001 4500.0 0.326 38.129 0.970 953.794 0.026 0.001 1.899 0.129 0.028 0.001 5000.0 0. 324 37.611 1.069 953.492 0.030 0.001 2.068 0.154 0.037 0.001 5500.0 0. 322 37.099 1.166 953.191 0.035 0.002 2.229 0.180 0.047 0.002 6000.0 0. 320 36.593 1.262 952.889 0.039 0.002 2.383 0.207 0.057 0.002 6500.0 0.318 36.094 1.356 952.587 0.044 0.003 2.530 0.234 0.069 0.003 7000.0 0.316 35.601 1.449 952.285 0.048 0.003 2.670 0.263 0.081 0.004 7500.0 0.314 35.114 1.541 951.983 0.053 0.004 2.804 0.292 0.095 0.005 8000.0 0.312 34.632 1.631 951.681 0.058 0.004 2.932 0.322 0.109 0.006 8500.0 0.310 34.156 1.719 951.379 0.063 0.005 3.054 0.353 0.124 0.008 9000.0 0.308 33.685 1.807 951.077 0.069 0.006 3.171 0.384 0.140 0.009 9500.0 0.306 33.219 1.893 950.775 0.074 0.006 3.282 0.415 0.156 0.011 10000.0 0.304 32.759 1.978 950.474 0.080 0.007 3.388 0.447 0.173 0.013 10500.0 0.302 32.303 2.062 950.172 0.086 0.008 3.489 0.480 0.190 0.015 11000.0 0.300 31.852 2.144 949.870 0.091 0.009 3.586 0.513 0.208 0.017 11500.0 0.298 31.405 2.226 949.569 0.097 0.010 3.677 0.545 0.226 0.020 12000.0 0.296 30.963 2.306 949.267 0.103 0.011 3.764 0.579 0.244 0.022 12500.0 0.294 30.526 2.385 948.966 0.110 0.012 3.847 0.612 0.263 0.025 13000.0 0.292 30.093 2.463 948.665 0.116 0.013 3.926 0.646 0.282 0.028 13500.0 0.290 29.664 2.540 948.364 0.122 0.015 4.001 0.680 0.301 0.032 14000.0 0.288 29.239 2.616 948.063 0.128 0.016 4.071 0.714 0.321 0.035 14500.0 0.287 28.818 2.691 947.763 0.135 0.017 4.138 0.748 0.340 0.039 15000.0 0.285 28.401 2.764 947.462 0.141 0.019 4.201 0.782 0.360 0.043 15500.0 0.283 27.987 2.837 947.163 0.148 0.020 4.261 0.817 0.379 0.047 16000.0 0.281 27.578 2.909 946.863 0.154 0.022 4.317 0.851 0.399 0.051 16500.0 0.279 27.172 2.980 946.563 0.161 0.024 4.370 0.886 0.419 0.055 17000.0 0.278 26.769 3.050 946.264 0.167 0.025 4.420 0.920 0.438 0.060 17500.0 0.276 26.370 3.119 945.965 0.174 0.027 4.467 0.955 0.458 0.065 18000.0 0.274 25.974 3.188 945.665 0.181 0.029 4.512 0.989 0.477 0.070 18500.0 0.272 25.582 3.255 945.366 0.187 0.031 4.554 1.023 0.497 0.075 19000.0 0.271 25.193 3.321 945.065 0.194 0.033 4.593 1.057 0.516 0.081 19500.0 0.269 24.808 3.387 944.765 0.201 0.035 4.631 1.092 0.535 0.087 20000.0 0.267 24.426 3.452 944.463 0.208 0.037 4.666 1.126 0.555 0.092 20500.0 0.265 24.047 3.516 944.161 0.215 0.039 4.700 1.159 0.574 0.099 21000.0 0.264 23.672 3.579 943.857 0.222 0.042 4.731 1.193 0.593 0.105 21500.0 0.262 23.301 3.641 943.553 0.229 0.044 4.761 1.227 0 612 0.111 22000.0 0.260 22.933 3.702 943.247 0.236 0.046 4.790 1.260 0.631 0.118 22500.0 0.259 22.568 3.763 942.940 0.243 0.049 4. 817 1.293 0.650 0.125 25000.0 0.250 20.797 4.053 941.383 0.280 0.063 4.931 1.455 0.744 0.163 27500.0 0.242 19.112 4.322 939.792 0.317 0.079 5.015 1.612 0.835 0.206 30000.0 0.233 17.511 4.572 938.164 0.356 0.097 5.071 1.763 0.921 0.255 32500.0 0.225 15.994 4.801 936.498 0.394 0.117 5.105 1.907 1.001 0.308 35000.0 0.217 14.560 5.012 934.794 0.433 0.140 5.118 2.044 1.075 0.367 37500.0 0.209 13.207 5.203 933.050 0.471 0.164 5.115 2.174 1.142 0.430 40000.0 0.202 11.935 5.375 931.264 0.509 0.191 5.098 2.295 1.202 0.497 42500.0 0.194 10.743 5.529 929.436 0.547 0.218 5.070 2.409 1.256 0.568 45000.0 0.187 9.630 5.664 927.565 0.583 0.248 5.032 2.514 1.304 0.643 47500.0 0.179 8.596 5.782 925.649 0.618 0.278 4.986 2.611 1.344 0.721 50000.0 0.172 7.638 5.883 923.688 0.652 0.310 4.936 2.699 1.379 0.802 52500.0 0.165 6.757 5.966 921.682 0.685 0.342 4.882 2.779 1.408 0.886 55000.0 0.159 5.949 6.034 919.630 0.716 0.374 4.825 2.850 1.432 0.973 57500.0 0.152 5.214 6.085 917.533 0.745 0.406 4.768 2.913 1.450 1.061 60000.0 0.146 4.548 6.121 915.392 0.772 0.438 4.711 2.969 1.465 1.151 62500.0 0.140 3.949 6.142 913.208 0.797 0.469 4.655 3.017 1.475 1.242 65000.0 0.134 3.413 6.151 910.981 0.821 0.499 4.600 3.057 1.482 1.334 67500.0 0.128 2.937 6.146 908.714 0.842 0.528 4.549 3.092 1.486 1.426 70000.0 0.122 2.517 6.130 906.410 0.861 0.556 4.500 3.120 1.488 1.519 AREVA NP Inc.
Lontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-16 Table C.15 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 0.000 0.000 100.0 0.345 43.148 0.000 956.506 0.000 0.000 0.000 0.000 0.000 0.000 500.0 0.343 43.030 0.024 956.437 0.000 0.000 0.027 0.000 0.000 0.000 1000.0 0.340 42.559 0.121 956.159 0.002 0.000 0.251 0.002 0.001 0.000 1500.0 0.338 41.980 0.240 955.811 0.005 0.000 0.534 0.009 0.002 0.000 41.413 0.356 955.463 0.008 0.000 0.803 0.020 0.004 0.000 2000.0 0.335 40.855 0.470 955.116 0.011 0.000 1.060 0.034 0.008 0.000 2500.0 0.333 40.308 0.582 954.768 0.015 0.000 1.304 0.051 0.013 0.000 3000.0 0.330 39.769 0.691 954.421 0.019 0.001 1.538 0.070 3500.0 0.328 39.239 0.799 954.074 0.023 0.001 1.761 0.092 0.019 0.000 4000.0 0.325 38.717 0.904 953.726 0.028 0.001 1.974 0.115 0.027 0.001 4500.0 0.323 38.203 1.008 953.379 0.032 0.002 2.179 0.140 0.036 0.001 5000.0 0.321 37.696 1.110 953.032 0.037 0.002 2.374 0.166 0.047 0.002 5500.0 0.318 37.196 1.210 952.684 0.042 0.003 2.562 0.193 0.058 0.002 6000.0 0.316 36.704 1.308 952.337 0.048 0.003 2.742 0.221 0.071 0.003 6500.0 0.314 36.218 1.405 951.990 0.053 0.004 2.914 0.250 0.085 0.004 7000.0 0.311 35.738 1.500 951.643 0.059 0.004 3.079 0.280 0.100 0.005 7500.0 0.309 35.265 1.594 951.296 0.065 0.005 3.237 0.311 0.116 0.006 8000.0 0.307 34.798 1.686 950.949 0.071 0.006 3.389 0.343 0.133 0.007 8500.0 0.305 34.337 1.777 950.602 0.078 0.007 3.535 0.375 0.150 0.009 9000.0 0.302 33.881 1.866 950.255 0.084 0.008 3.674 0.407 0.168 0.011 9500.0 0.300 33.430 1.954 949.908 0.091 0.009 3.808 0.440 0.187 0.012 10000.0 0.298 32.986 2.040 949.562 0.098 0.010 3.936 0.474 0.206 0.014 10500.0 0.296 32.546 2.125 949.215 0.104 0.011 4.059 0.508 0.226 0.017 11000.0 0.294 32.111 2.209 948.869 0.111 0.013 4.177 0.543 0.247 0.019 11500.0 0.292 31.681 2.291 948.523 0.118 0.014 4.290 0.578 0.267 0.022 12000.0 0.289 31.257 2.373 948.177 0.126 0.016 4.398 0.613 0.288 0.025 12500.0 0.287 30.836 2.453 947.831 0.133 0.017 4.502 0.648 0.310 0.028 13000.0 0.285 30.421 2.532 947.485 0.140 0.019 4.601 0.684 0.331 0.031 13500.0 0.283 30.010 2.609 947.139 0.147 0.020 4.695 0.720 0.353 0.034 14000.0 0.281 29.603 2.686 946.794 0.155 0.022 4.786 0.756 0.375 0.038 14500.0 0.279 29.200 2.761 946.449 0.163 0.024 4.872 0.793 0.397 0.042 15000.0 0.277 28.802 2.835 946.104 0.170 0.026 4.955 0.829 0.419 0.046 15500.0 0.275 28.407 2.908 945.759 0.178 0.028 5.034 0.866 0.442 0.050 16000.0 0,273 28.017 2.980 945.415 0.186 0.030 5.109 0. 903 0,464 0.054 16500.0 0.271 27.630 3.051 945.070 0.193 0.033 5.180 0.940 0.486 0.059 17000.0 0.269 27.248 3.121 944.726 0.201 0.035 5.248 0.977 0.508 0.064 17500.0 0.267 26.869 3.190 944.382 0.209 0.037 5.313 1.014 0.531 0.069 18000.0 0.265 26.493 3.258 944.039 0.217 0.040 5.375 1.051 0.553 0.074 18500.0 0.263 26.121 3.325 943.695 0.225 0.043 5.434 1.088 0.575 0.079 19000.0 0.262 25.753 3.391 943.351 0.233 0.045 5.490 1.125 0.597 0.085 19500.0 0.260 25.388 3.456 943.007 0.241 0.048 5.544 1.162 0.619 0.090 20000.0 0.258 25.027 3.521 942.662 0.249 0.051 5.595 1.199 0.641 0.096 20500.0 0.256 24.669 3.584 942.317 0.257 0.054 5.644 1.236 0.662 0.102 21000.0 0.254 24.315 3.646 941.971 0.265 0.057 5.691 1.273 0.684 0.109 21500.0 0.252 23.964 3.708 941.625 0.273 0.060 5.735 1.309 0.706 0.115 22000.0 0.250 23.617 3.768 941.278 0.281 0.063 5.778 1.346 0.727 0.122 22500.0 0.249 23.272 3.828 940.929 0.289 0.067 5.820 1.382 0.749 0.129 23000.0 0.247 22.932 3.887 940.580 0.297 0.070 5.859 1.418 0.770 0.136 23500.0 0.245 22.595 3.945 940.229 0.305 0.074 5.897 1.455 0.791 0.143 24000.0 0.243 22.261 4.002 939.878 0.314 0.077 5.933 1.490 0.813 0.150 24500.0 0.242 21.931 4.058 939.525 0.322 0.081 5.968 1.526 0.834 0.158 25000.0 0.240 21.604 4.114 939.171 0.330 0.085 6.001 1.562 0.855 0.165 25500.0 0.238 21.280 4.168 938.816 0.338 0.089 6.033 1.597 0.876 0.173 27500.0 0.231 20.018 4.378 937.383 0.372 0.106 6.149 1.736 0.958 0.207 30000.0 0.223 18.515 4.623 935.562 0.414 0.129 6.267 1.905 1.058 0.252 32500.0 0.214 17.092 4.847 933.708 0.456 0.155 6.360 2.067 1.154 0.302 35000.0 0.206 15.747 5.052 931.822 0.497 0.183 6.430 2.223 1.244 0.355 37500.0 0.198 14.477 5.239 929.902 0.539 0.214 6.480 2.373 1.328 0.412 40000.0 0.191 13.282 5.406 927.950 0.579 0.247 6.513 2.516 1.407 0.472 42500.0 0.183 12.159 5.556 925.964 0.619 0.282 6.532 2.651 1.480 0.536 45000.0 0.176 11.106 5.689 923.945 0.658 0.318 6.538 2.779 1.546 0.602 47500.0 0.169 10.122 5.805 921.893 0.696 0.356 6.534 2.900 1.607 0.671 50000.0 0.163 9.204 5.904 919.808 0.732 0.396 6.520 3.013 1.663 0.743 52500.0 0.157 8.350 5.989 917.690 0.767 0.436 6.500 3.118 1.713 0.816 55000.0 0.150 7.558 6.058 915.541 0.800 0.477 6.473 3.216 1.757 0.892 57500.0 0.145 6.825 6.114 913.360 0.831 0.519 6.442 3.306 1.797 0.969 60000.0 0.139 6.150 6.156 911.149 0.860 0.560 6.408 3.390 1.832 1.048 62500.0 0.134 5.529 6.185 908.909 0.887 0.602 6.371 3.466 1.863 1.129 65000.0 0.129 4.960 6.202 906.641 0.913 0.643 6.333 3.535 1.890 1.211 67500.0 0.124 4.441 6.209 904.346 0.936 0.683 6.294 3.598 1.913 1.293 70000.0 0.119 3.968 6.204 902.026 0.957 0.722 6.255 3.654 1.932 1.377 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-17 Table C.16 [ ] Exposure-Dependent 0% Void Isotopics (kgIMTU Initial)
Exposure MWd/MTU U-234 u-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.091 0.000 956.564 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.971 0.023 956.511 0.000 0.000 0.021 0.000 0.000 0.000 500.0 0.343 42.495 0.112 956.295 0.002 0.000 0.198 0.002 0.000 0.000 1000.0 0.341 41.908 0.222 956.026 0.004 0.000 0.421 0.007 0.000 0.000 1500.0 0.339 41.330 0.330 955.756 0.006 0.000 0.633 0.016 0.001 0.000 2000.0 0.337 40.760 0.437 955.486 0.008 0.000 0.834 0.028 0.003 0.000 2500.0 0.335 40.199 0.541 955.216 0.011 0.000 1.026 0.043 0.005 0.000 3000.0 0.333 39.645 0.644 954.947 0.013 0.000 1.208 0.059 0.008 0.000 3500.0 0.331 39.098 0.745 954.677 0.016 0.001 1.382 0.078 0.012 0.000 4000.0 0.329 38.558 0.845 954.407 0.019 0.001 1.547 0.098 0.017 0.001 4500.0 0.327 38.025 0.943 954.137 0.023 0.001 1.705 0.120 0.023 0.001 5000.0 0.325 37.498 1.040 953.868 0.026 0.001 1.855 0.144 0.030 0.001 5500.0 0.323 36.977 1.136 953.598 0.030 0.001 1.998 0.168 0.038 0.002 6000.0 0.322 36.463 1.230 953.328 0.034 0.002 2.134 0.194 0.047 0.002 6500.0 0.320 35.954 1.322 953.059 0.037 0.002 2.264 0.220 0.057 0.003 7000.0 0.318 35.450 1.414 952.789 0.041 0.002 2.387 0.247 0.068 0.004 7500.0 0.316 34.952 1.504 952.520 0.046 0.003 2.504 0.275 0.079 0.005 8000.0 0.314 34.459 1.593 952.251 0.050 0.003 2.616 0.304 0.091 0.006 8500.0 0.312 33.972 1.680 951.982 0.054 0.004 2.722 0.333 0.104 0.007 9000.0 0.311 33.489 1.767 951.713 0.059 0.004 2.823 0.363 0.117 0.008 9500.0 0.309 33.010 1.852 951.445 0.063 0.005 2.919 0.393 0.131 0.010 10000.0 0.307 32.537 1.937 951.177 0.068 0.006 3.009 0.424 0.146 0.011 10500.0 0.305 32,068 2.020 950.909 0.073 0,006 3A095 0.455 0,161 0.013 11000.0 0.304 31.603 2.102 950.641 0.078 0.007 3.177 0.486 0.176 0.015 11500.0 0.302 31.142 2.183 950.373 0.083 0.008 3.254 0.517 0.191 0.018 12000.0 0.300 30.686 2.263 950.107 0.088 0.009 3.326 0.549 0.207 0.020 12500.0 0.298 30.233 2.342 949.840 0.093 0.010 3.395 0.581 0.223 0.023 13000.0 0.297 29.785 2.420 949.574 0.098 0.010 3.459 0.613 0.240 0.025 13500.0 0.295 29.340 2.496 949.308 0.104 0.011 3.520 0.646 0.256 0.028 14000.0 0.293 28.898 2.573 949.043 0.109 0.012 3.577 0.678 0.273 0.032 14500.0 0.291 28.460 2.648 948.778 0.114 0.013 3.631 0.711 0.289 0.035 15000.0 0.290 28.026 2.722 948.514 0.120 0.015 3.681 0.743 0.306 0.038 15500.0 0.288 27.595 2.795 948.249 0.125 0.016 3.728 0.776 0.323 0.042 16000.0 0.286 27.167 2.867 947.985 0.131 0.017 3.772 0.809 0.340 0.046 16500.0 0.285 26.743 2.939 947.720 0.137 0.018 3.814 0.841 0.357 0.050 17000.0 0.283 26.323 3.010 947.455 0.142 0.020 3.853 0.874 0.374 0.055 17500.0 0.282 25.905 3.080 947.189 0.148 0.021 3.890 0.906 0.391 0.059 18000.0 0.280 25.491 3.149 946.923 0.154 0.022 3.925 0.939 0.407 0.064 18500.0 0.278 25.081 3.217 946.655 0.160 0.024 3.957 0.971 0.424 0.069 19000.0 0.277 24.674 3.284 946.387 0.165 0.025 3.988 1.004 0.441 0.074 19500.0 0.275 24.270 3.351 946.117 0.171 0.027 4.017 1.036 0.458 0.079 20000.0 0.273 23.870 3.417 945.846 0.177 0.029 4.044 1.068 0.475 0.085 20500.0 0.272 23.474 3.482 945.574 0.184 0.030 4.070 1.100 0.492 0.091 21000.0 0.270 23.081 3.546 945.301 0.190 0.032 4.094 1.132 0.509 0.097 21500.0 0.268 22.691 3.609 945.026 0.196 0.034 4.117 1.163 0.526 0.103 22500.0 0.265 21.923 3.733 944.472 0.208 0.038 4.158 1.226 0.560 0.116 25000.0 0.257 20.063 4.030 943.060 0.241 0.049 4.238 1.379 0.643 0.153 27500.0 0.249 18.290 4.306 941.610 0.275 0.062 4.289 1.527 0.722 0.196 30000.0 0.241 16.604 4.563 940.118 0.309 0.077 4.316 1.669 0.796 0.245 32500.0 0.233 15.005 4.800 938.584 0.344 0.094 4.321 1.805 0.865 0.299 35000.0 0.225 13.493 5.017 937.004 0.379 0.112 4.308 1.933 0.927 0.359 37500.0 0.217 12.070 5.215 935.377 0.415 0.132 4.281 2.054 0.982 0.424 40000.0 0.209 10.735 5.392 933.698 0.450 0.154 4.243 2.166 1.030 .0.494 42500.0 0.201 9.489 5.551 931.967 0.485 0.178 4.195 2.270 1.072 0.570 45000.0 0.193 8.334 5.689 930.180 0.519 0.202 4.140 2.365 1.107 0.650 47500.0 0.186 7.269 5.808 928.336 0.552 0.228 4.080 2.451 1.136 0.734 50000.0 0.178 6.295 5.908 926.433 0.584 0.254 4.018 2.527 1.158 0.823 52500.0 0.170 5.410 5.989 924.469 0.614 0.280 3.955 2.594 1.176 0.915 55000.0 0.163 4.615 6.051 922.443 0.643 0.307 3.893 2.653 1.188 1.010 57500.0 0.156 3.906 6.095 920.357 0.670 0.333 3.832 2.702 1.196 1.107 60000.0 0.149 3.281 6.122 918.210 0.695 0.358 3.775 2.743 1.201 1.206 62500.0 0.142 2.735 6.133 916.006 0.718 0.382 3.721 2.777 1.202 1.307 65000.0 0.135 2.264 6.130 913.746 0.738 0.405 3.671 2.803 1.201 1.409 67500.0 0.128 1.861 6.112 911.435 0.757 0.426 3.626 2.824 1.199 1.510 70000.0 0.122 1.521 6.083 909.077 0.773 0.445 3.585 2.839 1.194 1.612 AREVA NP Inc.
c;ontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-18 Table C.17 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.091 0.000 956.564 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.972 0.023 956.503 0.000 0.000 0.024 0.000 0.000 0.000 500.0 0.342 42.497 0.116 956.259 0.002 0.000 0.223 0.002 0.000 0.000 1000.0 0.340 41.914 0.230 955.953 0.004 0.000 0.474 0.008 0.000 0.000 1500.0 0.338 41.340 0.342 955.648 0.007 0.000 0.713 0.018 0.001 0.000 2000.0 0.336 40.776 0.452 955.342 0.009 0.000 0.939 0.031 0.003 0.000 2500.0 0.334 40.220 0.559 955.037 0.012 0.000 1.155 0.047 0.006 0.000 3000.0 0.332 39.674 0.665 954.732 0.016 0.000 1.360 0.065 0.010 0.000 3500.0 0.329 39.134 0.769 954.427 0.019 0.001 1.556 0.086 0.015 0.000 4000.0 0.327 38.603 0.871 954.123 0.023 0.001 1.743 0.108 0.022 0.001 4500.0 0.325 38.079 0.972 953.818 0.027 0.001 1.920 0.131 0.029 0.001 5000.0 0.323 37.562 1.071 953.514 0.031 0.002 2.090 0.156 0.038 0.001 5500.0 0.321 37.051 1.168 953.209 0.035 0.002 2.252 0.183 0.048 0.002 6000.0 0.319 36.547 1.264 952.905 0.040 0.002 2.406 0.210 0.059 0.003 6500.0 0.317 36.049 1.358 952.601 0.044 0.003 2.553 0.238 0.071 0.003 7000.0 0.315 35.558 1.451 952.298 0.049 0.003 2.694 0.267 0.083 0.004 7500.0 0.313 35.072 1.542 951.994 0.054 0.004 2.828 0.296 0.097 0.005 8000.0 0.311 34.591 1.632 951.691 0.059 0.004 2.955 0.326 0.111 0.007 8500.0 0.309 34.117 1.721 951.388 0.064 0.005 3.077 0.357 0.126 0.008 9000.0 0.307 33.647 1.808 951.085 0.069 0.006 3.193 0.389 0.142 0.010 9500.0 0.305 33.182 1.894 950.783 0.075 0.007 3.303 0.420 0.159 0.011 10000.0 0.303 32.723 1.979 950.480 0.081 0.007 3.408 0.453 0.176 0.013 10500.0 0.301 32.268 2.063 950.179 0.086 0.008 3.508 0.485 0.193 0.015 11000.0 0.299 31.818 2.145 949.877 0.092 0.009 3.603 0.518 0.211 0.018 11500.0 0.297 31.373 2.226 949.576 0.098 0.010 3.693 0.551 0.229 0.020 12000.0 0.295 30.932 2.306 949.276 0.104 0.011 3.779 0.585 0.247 0.023 12500.0 0.293 30.495 2.385 948.975 0.110 0.012 3.860 0.618 0.266 0.026 13000.0 0.292 30.062 2.463 948.676 0.116 0.014 3.937 0.652 0.285 0.029 13500.0 0.290 29.634 2.539 948.377 0.122 0.015 4.009 0.686 0.304 0.032 14000.0 0.288 29.209 2.615 948.078 0.129 0.016 4.078 0.720 0.323 0.036 14500.0 0.286 28.788 2.690 947.780 0.135 0.018 4.143 0.755 0.343 0.039 15000.0 0.284 28.371 2.764 947.482 0.141 0.019 4.204 0.789 0.362 0.043 15500.0 0.282 27.957 2.836 947.185 0.148 0.021 4.262 0.823 0.381 0.047 16000.0 0.281 27.547 2.908 946.887 0.154 0.022 4.317 0.858 0.401 0.052 16500.0 0.279 27.141 2.979 946.590 0.161 0.024 4.368 0.892 0.420 0.056 17000.0 0.277 26.738 3.049 946.293 0.167 0.025 4.417 0.927 0.440 0.061 17500.0 0.275 26.338 3.118 945.995 0.174 0.027 4.463 0.961 0.459 0.066 18000.0 0.274 25.942 3.186 945.697 0.180 0.029 4.507 0.995 0.478 0.071 18500.0 0.272 25.550 3.254 945.398 0.187 0.031 4.548 1.029 0.498 0.076 19000.0 0.270 25.161 3.320 945.099 0.194 0.033 4.587 1.063 0.517 0.082 19500.0 0.268 24.776 3.386 944.799 0.201 0.035 4.624 1.097 0.536 0.087 20000.0 0.267 24.394 3.450 944.497 0.208 0.037 4.660 1.131 0.556 0.093 20500.0 0.265 24.015 3.514 944.195 0.215 0.039 4.693 1.165 0.575 0.099 21000.0 0.263 23.640 3.577 943.891 0.222 0.042 4.725 1.198 0.594 0.106 21500.0 0.261 23.269 3.639 943.586 0.229 0.044 4.755 1.232 0.613 0.112 22000.0 0.260 22.901 3.701 943.280 0.236 0.046 4.784 1.265 0.632 0.119 22500.0 0.258 22.537 3.761 942.973 0.243 0.049 4.811 1.298 0.651 0.126 23000.0 0.256 22.176 3.821 942.664 0.250 0.052 4.836 1.331 0.670 0.133 23500.0 0.255 21.818 3.879 942.355 0.257 0.054 4.861 1.363 0.689 0.141 25000.0 0.250 20.767 4.051 941.416 0.280 0.063 4.926 1.460 0.745 0.164 27500.0 0.241 19.083 4.320 939.823 0.317 0.079 5.010 1.616 0.836 0.208 30000.0 0.233 17.483 4.569 938.194 0.355 0.097 5.067 1.766 0.922 0.256 32500.0 0.225 15.968 4.799 936.528 0.394 0.118 5.101 1.910 1.002 0.310 35000.0 0.217 14.535 5.008 934.822 0.433 0.140 5.115 2.047 1.076 0.368 37500.0 0.209 13.184 5.199 933.076 0.471 0.164 5.112 2.176 1.143 0.431 40000.0 0.201 11.913 5.371 931.289 0.509 0.191 5.095 2.297 1.203 0.498 42500.0 0.194 10.723 5.525 929.460 0.546 0.219 5.067 2.411 1.257 0.569 45000.0 0.186 9.612 5.660 927.587 0.583 0.248 5.029 2.516 1.304 0.644 47500.0 0.179 8.579 5.778 925.670 0.618 0.279 4.984 2.612 1.345 0.723 50000.0 0.172 7.623 5.878 923.708 0.652 0.310 4.934 2.700 1.379 0.804 52500.0 0.165 6.743 5.961 921.700 0.684 0.342 4.880 2.780 1.408 0.888 55000.0 0.158 5.937 6.028 919.648 0.715 0.374 4.823 2.851 1.432 0.975 57500.0 0.152 5.203 6.079 917.550 0.744 0.406 4.766 2.914 1.450 1.063 60000.0 0.145 4.539 6.115 915.407 0.772 0.438 4.709 2.969 1.465 1.153 62500.0 0.139 3.941 6.136 913.221 0.797 0.469 4.653 3.017 1.475 1.244 65000.0 0.133 3.406 6.144 910.993 0.820 0.499 4.599 3.058 1.482 1.336 67500.0 0.128 2.932 6.139 908.726 0.841 0.528 4.548 3.092 1.486 1.428 70000.0 0.122 2.513 6.123 906.421 0.860 0.555 4.499 3.120 1.488 1.520 AREVA NP Inc.
uontroiled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-19 Table C.18 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.000 0.000 0.0 0.345 43.091 0.000 956.564 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.972 0.024 956.494 0.000 0.000 0.027 0.000 0.000 0.000 500.0 0.342 42.502 0.122 956.212 0.002 0.000 0.255 0.002 0.001 0.000 1000.0 0.340 41.924 0.241 955.859 0.005 0.000 0.542 0.009 0.002 0.000 1500.0 0.337 41.357 0.357 955.507 0.008 0.000 0.814 0.020 0.004 0.000 2000.0 0.335 40.800 0.472 955.155 0.012 0.000 1.074 0.034 0.008 0.000 2500.0 0.332 40.253 0.583 954.803 0.015 0.000 1.321 0.052 0.013 0.000 3000.0 0.330 39.715 0.693 954.452 0.019 0.001 1.557 0.071 0.020 0.000 3500.0 0.327 39.186 0.801 954.101 0.023 0.001 1.782 0.093 0.028 0.001 4000.0 0.325 38.666 0.906 953.750 0.028 0.001 1.997 0.117 0.037 0.001 4500.0 0.322 38.153 1.010 953.400 0.033 0.002 2.203 0.142 0.048 0.002 5000.0 0.320 37.647 1.112 953.050 0.038 0.002 2.399 0.168 0.060 0.002 5500.0 0.318 37.149 1.212 952.700 0.043 0.003 2.588 0.195 6000.0 0.315 36.658 1.311 952.350 0.048 0.003 2.768 0.224 0.073 0.003 6500.0 0.313 36.173 1.407 952.001 0.054 0.004 2.941 0.253 0.087 0.004 7000.0 0.311 35.695 1.503 951.652 0.060 0.005 3.106 0.284 0.102 0.005 7500.0 0.308 35.223 1.596 951.303 0.066 0.005 3.264 0.315 0.118 0.006 8000.0 0.306 34.757 1.688 950.954 0.072 0.006 3.416 0.346 0.135 0.008 8500.0 0.304 34.297 1.778 950.606 0.079 0.007 3.561 0.379 0.153 0.009 9000.0 0.302 33.843 1.867 950.258 0.085 0.008 3.700 0.412 0.171 0.011 9500.0 0.299 33.394 1.955 949.910 0.092 0.009 3.833 0.445 0.190 0.013 10000.0 0.297 32.950 2.041 949.563 0.098 0.010 3.961 0.479 0.210 0.015 10500.0 0.295 32.512 2.126 949.216 0.105 0.012 4.083 0.513 0.230 0.017 11000.0 0.293 32.078 2.210 948.870 0.112 0.013 4.200 0.548 0.250 0.020 11500.0 0.291 31.649 2.292 948.524 0.119 0.014 4.311 0.583 0.271 0.022 12000.0 0.289 31.226 2.373 948.178 0.126 0.016 4.418 0.619 0.292 0.025 12500.0 0.287 30.806 2.453 947.833 0.134 0.017 4.520 0.654 0.313 0.028 13000.0 0.285 30.391 2.532 947.488 0.141 0.019 4.617 0.690 0.335 0.031 13500.0 0.282 29.981 2.609 947.143 0.148 0.021 4.710 0.726 0.357 0.035 14000.0 0.280 29.575 2.686 946.799 0.156 0.023 4.798 0.763 0.378 0.039 14500.0 0.278 29.173 2.761 946.456 0.163 0.024 4.883 0.799 0.400 0.042 15000.0 0.276 28.775 2.835 946.113 0.171 0.026 4.963 0.836 0.422 0.046 15500.0 0.274 28.380 2.908 945.770 0.178 0.028 5.040 0.873 0.445 0.051 16000.0 0.273 27.990 2.980 945.428 0.186 0.031 5.113 0.910 0.467 0.055 16500.0 0.271 27.604 3.050 945.087 0.194 0.033 5.183 0.947 0.489 0.060 17000.0 0.269 27.221 3.120 944.745 0.201 0.035 5.249 0.984 0.511 0.064 17500.0 0.267 26.841 3.189 944.403 0.209 0.038 5.312 1.021 0.533 0.069 18000.0 0.265 26.466 3.257 944.061 0.217 0.040 5.373 1.058 0.555 0.075 18500.0 0.263 26.094 3.324 943.719 0.225 0.043 5.430 1.095 0.577 0.080 19000.0 0.261 25.726 3.390 943.377 0.233 0.045 5.486 1.132 0.599 0.085 19500.0 0.259 25.361 3.455 943.034 0.241 0.048 5.538 1.169 0.620 0.091 20000.0 0.257 24.999 3.519 942.690 0.249 0.051 5.589 1.206 0.642 0.097 20500.0 0.255 24.641 3.582 942.346 0.257 0.054 5.638 1.242 0.664 0.103 21000.0 0.254 24.287 3.644 942.001 0.265 0.057 5.684 1.279 0.686 0.109 21500.0 0.252 23.936 3.706 941.655 0.273 0.060 5.729 1.315 0.707 0.116 22000.0 0.250 23.589 3.766 941.307 0.281 0.063 5.772 1.352 0.729 0.123 22500.0 0.248 23.244 3.826 940.959 0.289 0.067 5.813 1.388 0.750 0.129 23000.0 0.246 22.904 3.885 940.610 0.297 0.070 5.852 1.424 0.772 0.136 23500.0 0.245 22.567 3.943 940.259 0.305 0.074 5.890 1.460 0.793 0.144 24000.0 0.243 22.233 4.000 939.908 0.314 0.077 5.927 1.496 0.814 0.151 24500.0 0.241 21.903 4.056 939.555 0.322 0.081 5.962 1.531 0.835 0.159 25000.0 0.239 21.576 4.111 939.201 0.330 0.085 5.995 1.567 0.856 0.166 25500.0 0.238 21.253 4.166 938.845 0.338 0.089 6.027 1.602 0.877 0.174 26000.0 0.236 20.933 4.220 938.489 0.347 0.093 6.058 1.637 0.898 0.182 27500.0 0.231 19.992 4.376 937.411 0.372 0.106 6.143 1.741 0.960 0.208 30000.0 0.222 18.490 4.620 935.589 0.413 0.129 6.262 1.908 1.060 0.253 32500.0 0.214 17.068 4.844 933.734 0.455 0.155 6.356 2.070 1.155 0.303 35000.0 0.206 15.724 5.049 931.847 0.497 0.184 6.426 2.226 1.245 0.356 37500.0 0.198 14.456 5.235 929.927 0.538 0.214 6.477 2.376 1.330 0.414 40000.0 0.190 13.262 5.402 927.973 0.579 0.247 6.511 2.518 1.408 0.474 42500.0 0.183 12.140 5.552 925.986 0.619 0.282 6.529 2.653 1.481 0.537 45000.0 0.176 11.089 5.684 923.966 0.658 0.319 6.536 2.781 1.547 0.604 47500.0 0.169 10.106 5.800 921.913 0.695 0.357 6.532 2.901 1.608 0.673 50000.0 0.163 9.189 5.899 919.827 0.732 0.396 6.518 3.014 1.664 0.744 52500.0 0.156 8.336 5.983 917.708 0.766 0.436 6.498 3.119 1.713 0.818 55000.0 0.150 7.545 6.053 915.558 0.799 0.477 6.472 3.217 1.758 0.893 57500.0 0.144 6.814 6.108 913.376 0.830 0.519 6.441 3.307 1.798 0.971 60000.0 0.139 6.140 6.150 911.165 0.860 0.560 6.407 3.390 1.833 1.050 62500.0 0.133 5.520 6.179 908.924 0.887 0.602 6.371 3.466 1.863 1.130 65000.0 0.128 4.952 6.196 906.655 0.912 0.643 6.332 3.535 1.890 1.212 67500.0 0.124 4.434 6.202 904.359 0.935 0.683 6.294 3.598 1.913 1.295 70000.0 0.119 3.961 6.198 902.038 0.957 0.722 6.254 3.654 1.933 1.378 AREVA NP Inc.
Uontrolled Vocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-20 Table C.19 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure NWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.634 0.000 956.017 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.514 0.022 955.969 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.347 43.036 0.110 955.776 0.001 0.000 0.173 0.001 0.000 0.000 1000.0 0.345 42.446 0.217 955.534 0.003 0.000 0.374 0.006 0.000 0.000 1500.0 0.344 41.864 0.324 955.292 0.005 0.000 0.565 0.014 0.001 0.000 2000.0 0.342 41.290 0.428 955.050 0.007 0.000 0.747 0.024 0.002 0.000 2500.0 0.340 40.722 0.532 954.808 0.009 0.000 0.921 0.037 0.004 0.000 3000.0 0.338 40.161 0.633 954.566 0.012 0.000 1.086 0.052 0.006 0.000 3500.0 0.336 39.606 0.733 954.324 0.015 0.000 1.244 0.068 0.009 0.000 4000.0 0.335 39.058 0.832 954.082 0.017 0.001 1.394 0.087 0.013 0.000 4500.0 0.333 38.516 0.930 953.840 0.020 0.001 1.538 0.107 0.018 0.001 5000.0 0.331 37.979 1.026 953.598 0.023 0.001 1.674 0.128 0.024 0.001 5500.0 0.329 37.448 1.121 953.356 0.026 0.001 1.804 0.150 0.031 0.001 6000.0 0.328 36.923 1.214 953.114 0.030 0.001 1.928 0.173 0.038 0.002 6500.0 0.326 36.402 1.307 952.872 0.033 0.002 2.045 0.198 0.046 0.002 7000.0 0.324 35.887 1.398 952.630 0.037 0.002 2.157 0.223 0.055 0.003 7500.0 0.322 35.376 1.488 952.389 0.040 0.002 2.264 0.249 0.064 0.003 8000.0 0.321 34.871 1.578 952.147 0.044 0.003 2.365 0.275 0.074 0.004 8500.0 0.319 34.369 1.665 951.906 0.048 0.003 2.461 0.302 0.085 0.005 9000.0 0.317 33.873 1.752 951.665 0.052 0.004 2.552 0.330 0.097 0.006 9500.0 0.316 33.380 1.838 951.424 0.056 0.004 2.638 0.358 0.108 0.008 10000.0 0.314 32.892 1.923 951.183 0.060 0.005 2.720 0.387 0.121 0.009 10500.0 0.312 32.408 2.007 950.943 0.064 0.005 2.797 0.416 0.133 0.011 11000.0 0.311 31.928 2.090 950.703 0.069 0.006 2.870 0.445 0.146 0.012 11500.0 0.309 31.452 2.171 950.463 0.073 0.006 2.939 0.475 0.160 0.014 12000.0 0.307 30.980 2.252 950.223 0.078 0.007 3.004 0.505 0.174 0.016 12500.0 0.306 30.511 2.332 949.984 0.082 0.008 3.065 0.536 0.188 0.018 13000.0 0.304 30.046 2.411 949.746 0.087 0.008 3.122 0.566 0.202 0.021 13500.0 0.303 29.584 2.489 949.507 0.091 0.009 3.176 0.597 0.216 0. 023 14000.0 0.301 29.126 2.567 949.270 0.096 0.010 3.226 0.628 0.231 0.026 14500.0 0.299 28.671 2.643 949.032 0.101 0.011 3.272 0.659 0.245 0. 028 15000.0 0.298 28.219 2.719 948.796 0.106 0.012 3.316 0.690 0.260 0.032 15500.0 0.296 27.771 2.793 948.559 0.111 0.013 3.356 0.721 0.274 0.035 16000.0 0.295 27.325 2.867 948.322 0.116 0.014 3.394 0.752 0.289 0.038 16500.0 0.293 26.882 2.940 948.086 0.120 0.015 3.429 0.783 0.304 0.042 17000.0 0.291 26.443 3.013 947.849 0.125 0.016 3.462 0.815 0.319 0.045 17500.0 0.290 26.007 3.084 947.611 0.130 0.017 3.492 0.846 0.333 0.049 18000.0 0.288 25.574 3.155 947.373 0.136 0.018 3.521 0.877 0.348 0.053 18500.0 0.287 25.144 3.225 947.133 0.141 0.019 3.548 0.908 0.363 0.058 19000.0 0.285 24.718 3.295 946.893 0.146 0.020 3.573 0.939 0.378 0.062 20000.0 0.282 23.875 3.431 946.408 0.157 0.023 3.618 1.001 0.408 0.072 22500.0 0.274 21.827 3.759 945.171 0.184 0.031 3.707 1.153 0.484 0.100 25000.0 0.266 19.864 4.067 943.897 0.213 0.040 3.764 1.302 0.558 0.133 27500.0 0.258 17.986 4.356 942.581 0.243 0.050 3.795 1.446 0.628 0.173 30000.0 0.250 16.196 4.626 941.222 0.275 0.062 3.802 1.586 0.694 0.218 32500.0 0.242 14.494 4.876 939.814 0.307 0.076 3.790 1.719 0.754 0.270 35000.0 0.234 12.884 5.106 938.356 0.339 0.091 3.762 1.845 0.808 0 .327 37500.0 0.226 11.367 5.316 936.842 0.372 0.108 3.721 1.964 0.856 0.391 40000.0 0.218 9.947 5.505 935.268 0.405 0.126 3.670 2.074 0.897 0.461 42500.0 0.210 8.627 5.673 933.630 0.437 0.146 3.612 2.175 0.931 0.537 45000.0 0.201 7.410 5.820 931.923 0.469 0.167 3.549 2.268 0.959 0.619 47500.0 0.193 6.299 5.945 930.142 0.500 0.188 3.484 2.350 0.981 0.707 50000.0 0.185 5.296 6.047 928.284 0.530 0.210 3.418 2.422 0.997 0.800 52500.0 0.176 4.401 6.128 926.347 0.559 0.233 3.354 2.485 1.008 0.897 55000.0 0.168 3.614 6.187 924.330 0.586 0.255 3.293 2.537 1.015 0.999 57500.0 0.160 2.933 6.226 922.231 0.610 0.277 3.236 2.581 1.018 1.105 60000.0 0.152 2.353 6.244 920.055 0.633 0.297 3.184 2.615 1.018 1.213 62500.0 0.144 1.868 6.245 917.805 0.654 0.317 3.138 2.641 1.016 1.322 65000.0 0.136 1.468 6.229 915.487 0.672 0.335 3.097 2.661 1.013 1.433 67500.0 0.128 1.144 6.199 913.109 0.687 0.351 3.062 2.674 1.009 1.544 70000.0 0.121 0.885 6.156 910.679 0.701 0.365 3.032 2.683 1.004 1.654 AREVA NP Inc.
(ontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-21 Table C.20 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 u-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.634 0.000 956.017 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.514 0.023 955.962 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.347 43.038 0.114 955.741 0.002 0.000 0.197 0.002 0.000 0.000 1000.0 0.345 42.451 0.226 955.464 0.004 0.000 0.426 0.007 0.000 0.000 1500.0 0.343 41.873 0.335 955.187 0.006 0.000 0.643 0.016 0.001 0.000 2000.0 0.341 41.304 0.443 954.910 0.009 0.000 0.850 0.027 0.003 0.000 2500.0 0.339 40.742 0.550 954.633 0.011 0.000 1.048 0.042 0.005 0.000 3000.0 0.337 40.188 0.654 954.357 0.014 0.000 1.236 0.058 0.008 0.000 3500.0 0.335 39.641 0.757 954.080 0.017 0.001 1.415 0.076 0.012 0.000 4000.0 0.333 39.100 0.858 953.804 0.021 0.001 1.585 0.097 0.018 0.000 4500.0 0.331 38.567 0.958 953.528 0.024 0.001 1.748 0.118 0.024 0.001 5000.0 0.329 38.040 1.056 953.252 0.028 0.001 1.903 0.141 0.031 0.001 5500.0 0.327 37.519 1.153 952.977 0.032 0.002 2.051 0.165 0.039 0.001 6000.0 0.325 37.004 1.248 952.701 0.035 0.002 2.192 0.191 0.048 0.002 6500.0 0.323 36.494 1.342 952.426 0.040 0.002 2.327 0.217 0.059 0.003 7000.0 0.321 35.991 1.435 952.151 0.044 0.003 2.455 0.244 0.069 0.003 7500.0 0.319 35.492 1.526 951.877 0.048 0.003 2.576 0.271 0.081 0.004 8000.0 0.317 34.999 1.617 951.602 0.053 0.004 2.692 0.300 0.094 0.005 8500.0 0.316 34.511 1.705 951.328 0.057 0.004 2.803 0.329 0.107 0.006 9000.0 0.314 34.028 1.793 951.054 0.062 0.005 2.907 0.358 0.121 0.008 9500.0 0.312 33.549 1.879 950.781 0.067 0.005 3.007 0.388 0.135 0.009 10000.0 0.310 33.075 1.965 950.508 0.072 0.006 3.101 0.418 0.150 0.011 10500.0 0.308 32.606 2.049 950.235 0.077 0.007 3.191 0.449 0.165 0.013 11000.0 0.306 32.141 2.132 949.963 0.082 0.008 3.276 0.480 0.181 0.015 11500.0 0.305 31.680 2.214 949.691 0.088 0.008 3.356 0.512 0.197 0.017 12000.0 0.303 31.223 2.294 949.419 0.093 0.009 3.432 0.544 0.213 0.019 12500.0 0.301 30.771 2.374 949.148 0.098 0.010 3.504 0.576 0.230 0.021 13000.0 0.299 30.322 2.453 948.878 0.104 0.011 3.571 0.608 0.247 0.024 13500.0 0.297 29.877 2.531 948.608 0.110 0.012 3.634 0.641 0.264 0.027 14000.0 0.296 29.435 2.608 948.338 0.115 0.013 3.694 0.673 0.281 0.030 14500.0 0.294 28.998 2.683 948.069 0.121 0.014 3.750 0.706 0.298 0.033 15000.0 0.292 28.563 2.758 947.801 0.126 0.016 3.802 0.739 0.315 0.037 15500.0 0.290 28.132 2.832 947.533 0.132 0.017 3.851 0.772 0.333 0.040 16000.0 0.289 27.705 2.906 947.266 0.138 0.018 3.897 0.805 0.350 0.044 16500.0 0.287 27.281 2.978 946.999 0.144 0.019 3.940 0.838 0.367 0.048 17000.0 0.285 26.860 3.049 946.732 0.150 0.021 3.980 0.871 0.385 0.052 17500.0 0.284 26.442 3.120 946.464 0.155 0.022 4.017 0.904 0.402 0.057 18000.0 0.282 26.027 3.190 946.197 0.161 0.024 4.052 0.937 0.419 0.061 18500.0 0.280 25.616 3.259 945.928 0.167 0.025 4.085 0.970 0.436 0.066 19000.0 0.279 25.208 3.327 945.659 0.173 0.027 4.117 1.002 0.454 0.071 19500.0 0.277 24.803 3.394 945.389 0.179 0.029 4.146 1.035 0.471 0.076 20000.0 0.275 24.402 3.461 945.118 0.186 0.030 4.173 1.068 0.488 0.081 20500.0 0.274 24.004 3.526 944.845 0.192 0.032 4.199 1.100 0.506 0.087 22500.0 0.267 22.447 3.781 943.742 0.217 0.040 4.288 1.228 0.575 0.112 25000.0 0.259 20.577 4.082 942.332 0.251 0.051 4.370 1.383 0.660 0.147 27500.0 0.251 18.792 4.362 940.884 0.285 0.064 4.422 1.534 0.741 0.188 30000.0 0.243 17.092 4.623 939.398 0.320 0.079 4.449 1.679 0.817 0.235 32500.0 0.235 15.477 4.864 937.871 0.356 0.096 4.455 1.818 0.888 0.287 35000.0 0.227 13.948 5.086 936.300 0.392 0.115 4.442 1.950 0.952 0.344 37500.0 0.218 12.505 5.288 934.684 0.428 0.136 4.415 2.074 1.009 0.407 40000.0 0.211 11.148 5.471 933.019 0.464 0.158 4.375 2.190 1.060 0.475 42500.0 0.203 9.880 5.634 931.304 0.499 0.181 4.326 2.298 1.104 0.548 45000.0 0.195 8.700 5.777 929.535 0.533 0.206 4.269 2.397 1.141 0.626 47500.0 0.187 7.609 5.902 927.710 0.566 0.232 4.207 2.486 1.171 0.708 50000.0 0.179 6.608 6.006 925.828 0.599 0.259 4.142 2.566 1.195 0.794 52500.0 0.172 5.696 6.092 923.886 0.629 0.286 4.076 2.637 1.214 0.883 55000.0 0.164 4.872 6.159 921.884 0.659 0.313 4.010 2.699 1.227 0.976 57500.0 0.157 4.136 6.208 919.821 0.686 0.340 3.946 2.752 1.236 1.072 60000.0 0.150 3.484 6.239 917.699 0.711 0.366 3.884 2.796 1.241 1.169 62500.0 0.143 2.912 6.253 915.518 0.734 0.391 3.826 2.832 1.242 1.269 65000.0 0.136 2.417 6.253 913.281 0.755 0.415 3.773 2.860 1.242 1.369 67500.0 0.129 1.992 6.238 910.992 0.774 0.437 3.724 2.882 1.239 1.470 70000.0 0.123 1.631 6.210 908.655 0.791 0.458 3.680 2.899 1.234 1.570 AREVA NP Inc.
Uontrolled Document Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-22 Table C.21 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 0.000 0.000 0.000 100.0 0.349 43.634 0.000 956.017 0.000 0.000 0.000 0.000 0.000 0.000 500.0 0.347 43.515 0.024 955.952 0.000 0.000 0.023 0.002 0.000 0.000 43.042 0.120 955.691 0.002 0.000 0.230 0.008 0.000 0.000 1000.0 0.344 42.460 0.237 955.365 0.005 0.000 0.496 0.018 0.002 0.000 1500.0 0.342 41.889 0.352 955.039 0.007 0.000 0.749 0.031 0.004 0.000 2000.0 0.339 41.327 0.465 954.714 0.011 0.000 0.991 0.047 0.007 0.000 2500.0 0.337 40.774 0.575 954.389 0.014 0.000 1.221 0.065 0.011 0.000 3000.0 0.335 40.229 0.684 954.064 0.018 0.001 1.441 0.085 0.017 0.000 3500.0 0.332 39.692 0.791 953.740 0.022 0.001 1.650 0.107 0.024 0.001 4000.0 0.330 39.163 0.896 953.415 0.026 0.001 1.850 4500.0 0.328 38.642 0.999 953.092 0.030 0.001 2.042 0.131 0.032 0.001 5000.0 0.326 38.127 1.101 952.768 0.035 0.002 2.224 0.155 0.041 0.001 5500.0 0.323 37.619 1.200 952.445 0.039 0.002 2.399 0.181 0.052 0.002 6000.0 0.321 37.118 1.299 952.122 0.044 0.003 2.566 0.208 0.063 0.002 6500.0 0.319 36.623 1.395 951.800 0.050 0.003 2.726 0.236 0.076 0.003 7000.0 0.317 36.134 1.490 951.478 0.055 0.004 2.878 0.265 0.090 0.004 7500.0 0.314 35.651 1.584 951.156 0.061 0.005 3.024 0.294 0.104 0.005 8000.0 0.312 35.174 1.676 950.835 0.066 0.005 3.163 0.325 0.120 0.006 8500.0 0.310 34.702 1.766 950.514 0.072 0.006 3.296 0.356 0.136 0.008 9000.0 0.308 34.236 1.856 950.193 0.078 0.007 3.423 0.387 0.153 0.009 9500.0 0.306 33.774 1.944 949.873 0.084 0.008 3.544 0.419 0.170 0.011 10000.0 0.304 33.318 2.030 949.554 0.090 0.009 3.660 0.451 0.188 0.013 10500.0 0.302 32.867 2.116 949.235 0.097 0.010 3.770 0.484 0.206 0.015 11000.0 0.300 32.420 2.200 948.916 0.103 0.011 3.876 0.517 0.225 0.017 11500.0 0.298 31.979 2.283 948.597 0.110 0.012 3.976 0.551 0.244 0.019 12000.0 0.296 31.541 2.365 948.280 0.116 0.014 4.071 0.585 0.264 0.022 12500.0 0.294 31.109 2.445 941.962 0.123 0.015 4.162 0.619 0.284 0.025 13000.0 0.292 30.680 2.525 947.646 0.130 0.016 4.248 0.654 0.304 0.028 13500.0 0.290 30.255 2.603 947.329 0.136 0.018 4.329 0.689 0.324 0.031 14000.0 0.288 29.835 2.680 947.013 0.143 0.019 4.407 0.724 0.344 0.034 14500.0 0.286 29.419 2.756 946.698 0.150 0.021 4.480 0.759 0.365 0.038 15000.0 0.284 29.006 2.831 946.384 0.157 0.023 4.550 0.794 0.385 0.041 15500.0 0.282 28.597 2.905 946.070 0.164 0.024 4.615 0.830 0.406 0.045 16000.0 0.280 28.192 2.978 945.757 0.171 0.026 4.677 0.865 0.426 0.049 16500.0 0.278 27.791 3.050 945.444 0.178 0.028 4.736 0.901 0.447 0.054 17000.0 0.276 27.393 3.121 945.132 0.186 0.030 4.791 0.937 0.467 0.058 17500.0 0.275 26.998 3.191 944.819 0.193 0.032 4.843 0.973 0.488 0.063 18000.0 0.273 26.607 3.260 944.507 0.200 0.034 4.893 1.008 0.508 0.068 18500.0 0.271 26.219 3.328 944.195 0.207 0.036 4.939 1.044 0.528 0.073 19000.0 0.269 25.834 3.395 943.883 0.214 0.039 4.983 1.080 0.549 0.078 19500.0 0.267 25.453 3.462 943.570 0.222 0.041 5.025 1.115 0.569 0.083 20000.0 0.266 25.076 3.527 943.256 0.229 0.043 5.065 1.151 0.589 0.089 20500.0 0.264 24.701 3.592 942.942 0.237 0.046 5.103 1.186 0.609 0.095 21000.0 0.262 24.330 3.656 942.626 0.244 0.049 5.139 1.221 0.629 0.101 21500.0 0.260 23.963 3.718 942.310 0.251 0.051 5.173 1.257 0.649 0.107 22000.0 0.258 23.599 3.781 941.993 0.259 0.054 5.206 1.292 0.669 0.113 22500.0 0.257 23.238 3.842 941.674 0.267 0.057 5.237 1.326 0.689 0.120 25000.0 0.248 21.486 4.135 940.061 0.305 0.072 5.371 1.497 0.788 0.156 27500.0 0.239 19.817 4.409 938.416 0.344 0.090 5.474 1.663 0.884 0.196 30000.0 0.231 18.230 4.662 936.737 0.384 0.110 5.548 1.823 0.976 0.242 32500.0 0.223 16.725 4.895 935.023 0.423 0.133 5.598 1.978 1.062 0.292 35000.0 0.215 15.300 5.109 933.274 0.463 0.157 5.627 2.126 1.143 0.346 37500.0 0.207 13.953 5.303 931.489 0.503 0.184 5.638 2.267 1.217 0.404 40000.0 0.199 12.685 5.479 929.666 0.542 0.212 5.633 2.400 1.286 0.467 42500.0 0.191 11.493 5.636 927.804 0.581 0.243 5.616 2.526 1.347 0.533 45000.0 0.184 10.378 5.775 925.904 0.618 0.274 5.587 2.643 1.403 0.602 47500.0 0.177 9.337 5.896 923.964 0.655 0.308 5.549 2.753 1.452 0.675 50000.0 0.170 8.369 6.000 921.984 0.690 0.342 5.505 2.853 1.494 0.751 52500.0 0.163 7.474 6.087 919.964 0.724 0.377 5.456 2.946 1.531 0.829 55000.0 0.156 6.648 6.158 917.903 0.756 0.413 5.402 3.030 1.563 0.910 57500.0 0.150 5.891 6.213 915.803 0.786 0.449 5.347 3.105 1.589 0.994 60000.0 0.143 5.200 6.254 913.663 0.814 0.485 5.290 3.173 1.610 1.079 62500.0 0.137 4.572 6.280 911.485 0.841 0.520 5.234 3.232 1.628 1.166 65000.0 0.132 4.005 6.293 909.269 0.865 0.554 5.178 3.285 1.641 1.254 67500.0 0.126 3.495 6.293 907.018 0.887 0.587 5.123 3.330 1.651 1.343 70000.0 0.121 3.040 6.282 904.732 0.907 0.619 5.071 3.368 1.657 1.434 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-23 Table C.22 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.648 0.000 956.003 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.528 0.022 955.955 0.000 0.000 0.017 0.000 0.000 0.000 500.0 0.347 43.050 0.110 955.763 0.001 0.000 0.172 0.001 0.000 0.000 1000.0 0.344 42.460 0.217 955.524 0.003 0.000 0.371 0.006 0.000 0.000 1500.0 0.344 41.878 0.324 955.284 0.005 0.000 0.560 0.014 0.001 0.000 2000.0 0.342 41.303 0.428 955.045 0.007 0.000 0.740 0.024 0.002 0.000 2500.0 0.340 40.734 0.531 954.806 0.009 0.000 0.912 0.037 0.004 0.000 3000.0 0.338 40.173 0.633 954.567 0.012 0.000 1.075 0.052 0.006 0.000 3500.0 0.337 39.618 0.733 954.329 0.014 0.000 1.229 0.068 0.009 0.000 4000.0 0.335 39.069 0.831 954.091 0.017 0.001 1.377 0.086 0.013 0.000 4500.0 0.333 38.525 0.929 953.854 0.020 0.001 1.517 0.106 0.018 0.001 5000.0 0.331 37.988 1.025 953.617 0.023 0.001 1.650 0.127 0.024 0.001 5500.0 0.330 37,455 1.120 953.380 0.026 0.001 1.776 0.149 0.030 0.001 6000.0 0.328 36.928 1.213 953.144 0.029 0.001 1.896 0.172 0.037 0.002 6500.0 0.326 36.406 1.306 952.909 0.032 0.002 2.010 0.196 0.045 0.002 7000.0 0.325 35.888 1.397 952.674 0.036 0.002 2.118 0.221 0.053 0.003 7500.0 0.323 35.375 1.487 952.440 0.039 0.002 2.221 0.247 0.062 0.003 8000.0 0.321 34.867 1.576 952.206 0.043 0.003 2.318 0.273 0.072 0.004 8500.0 0.320 34.363 1.664 951.973 0.047 0.003 2.409 0.300 0.082 0.005 9000.0 0.318 33.863 1.751 951.741 0.050 0.003 2.496 0.327 0.093 0.006 9500.0 0.316 33.367 1.836 951.509 0.054 0.004 2.578 0.355 0.104 0.007 10000.0 0.315 32.875 1.921 951.278 0.058 0.004 2.655 0.383 0.116 0.009 10500.0 0.313 32.387 2.005 951.048 0.062 0.005 2.728 0.412 0.128 0.010 11000.0 0.311 31.902 2.088 950.819 0.066 0.005 2.796 0.441 0.140 0.012 11500.0 0.310 31.421 2.170 950.590 0.070 0.006 2.861 0.470 0.153 0.013 12000.0 0.308 30.943 2.251 950.362 0.074 0.007 2.922 0.499 0.166 0.015 12500.0 0.307 30.469 2.331 950.133 0.079 0.007 2.979 0.529 0.179 0.017 13000.0 0.305 29.998 2.410 949.905 0.083 0.008 3.033 0.559 0.192 0.019 13500.0 0.304 29.531 2.489 949.676 0.088 0.009 3.084 0.588 0.205 0.022 14000.0 0.302 29.067 2.566 949.447 0.092 0.009 3.133 0.618 0.219 0.024 14500.0 0.300 28.607 2.643 949.217 0.097 0.010 3.179 0.649 0.233 0.027 15000.0 0.299 28.149 2.719 948.986 0.101 0.011 3.222 0.679 0.247 0.030 15500.0 0.297 27.696 2.794 948.754 0.106 0.012 3.264 0.709 0.262 0.033 17500.0 0.291 25.917 3.087 947.813 0.126 0.016 3.410 0.831 0.321 0.047 20000.0 0.283 23.773 3.435 946.608 0.152 0.022 3.551 0.983 0.397 0.069 22500.0 0.275 21.716 3.764 945.367 0.180 0.029 3.652 1.133 0.473 0.096 25000.0 0.267 19.746 4.073 944.088 0.210 0.038 3.720 1.282 0.548 0.129 27500.0 0.259 17.864 4.363 942.768 0.240 0.049 3.758 1.426 0.618 0.168 30000.0 0.251 16.071 4.633 941.404 0.272 0.061 3.772 1.566 0.684 0.213 32500.0 0.243 14.368 4.883 939.992 0.304 0.074 3.765 1.701 0.745 0.264 35000.0 0.235 12.758 5.112 938.528 0.337 0.090 3.741 1.828 0.799 0.322 37500.0 0.227 11.244 5.322 937.008 0.370 0.107 3.703 1.948 0.848 0.386 40000.0 0.218 9.827 5.510 935.427 0.403 0.125 3.655 2.060 0.889 0.456 42500.0 0.210 8.512 5.677 933.781 0.436 0.145 3.599 2.163 0.924 0.532 45000.0 0.202 7.301 5.822 932.066 0.468 0.165 3.538 2.257 0.952 0.614 47500.0 0.193 6.197 5.945 930.276 0.499 0.187 3.473 2.341 0.975 0.702 50000.0 0.185 5.201 6.046 928.409 0.529 0.209 3.409 2.415 0.991 0.795 52500.0 0.177 4.315 6.125 926.462 0.558 0.232 3.345 2.478 1.003 0.893 55000.0 0.168 3.538 6.183 924.434 0.585 0.254 3.285 2.532 1.010 0.995 57500.0 0.160 2.867 6.219 922.325 0.610 0.276 3.229 2.576 1.014 1.100 60000.0 0.152 2.296 6.236 920.139 0.632 0.297 3.178 2.611 1.014 1.209 62500.0 0.144 1.820 6.235 917.879 0.653 0.316 3.132 2.638 1.013 1.319 65000.0 0.136 1.428 6.217 915.553 0.671 0.334 3.093 2.658 1.010 1.430 67500.0 0.128 1.112 6.185 913.167 0.686 0.350 3.059 2.672 1.006 1.541 70000.0 0.121 0.859 6.142 910.730 0.700 0.365 3.029 2.681 1.002 1.651 AREVA NP Inc.
Uontronled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-24 Table C.23 [ ] Exposure-Dependent 40% Void Isotopics (kglMTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.000 0.000 0.000 0.000 0.0 0.349 43.648 0.000 956.003 0.000 0.000 0.019 0.000 0.000 0.000 100.0 0.349 43.528 0.023 955.948 0.000 0.000 0.195 0.002 0.000 0.000 500.0 0.347 43.052 0.114 955.729 0.002 0.000 0.422 0.007 0.000 0.000 1000.0 0.345 42.465 0.225 955.455 0.004 0.000 1500.0 0.343 41.887 0.335 955.181 0.006 0.000 0.636 0.016 0.001 0.000 2000.0 0.341 41.316 0.443 954.908 0.008 0.000 0.841 0.027 0.003 0.000 2500.0 0.339 40.754 0.549 954.635 0.011 0.000 1.035 0.041 0.005 0.000 3000.0 0.337 40.199 0.653 954.363 0.014 0.000 1.219 0.058 0.008 0.000 3500.0 0.335 39.652 0.756 954.092 0.017 0.001 1.395 0.076 0.012 0.000 4000.0 0.333 39.111 0.857 953.821 0.020 0.001 1.562 0.096 0.017 0.000 4500.0 0.331 38.576 0.957 953.550 0.024 0.001 1.721 0.118 0.023 0.001 5000.0 0.329 38.048 1.055 953.280 0.027 0.001 1.872 0.141 0.030 0.001 5500.0 0.327 37.525 1.151 953.011 0.031 0.001 2.015 0.165 0.038 0.001 6000.0 0.325 37.008 1.246 952.743 0.035 0.002 2.152 0.190 0.047 0.002 6500.0 0.324 36.497 1.340 952.475 0.039 0.002 2.282 0.215 0.057 0.003 7000.0 0.322 35.991 1.433 952.208 0.043 0.003 2.405 0.242 0.068 0.003 7500.0 0.320 35.491 1.524 951.941 0.047 0.003 2.522 0.270 0.079 0.004 8000.0 0.318 34.995 1.614 951.676 0.051 0.003 2.632 0.298 0.091 0.005 8500.0 0.316 34.504 1.703 951.411 0.056 0.004 2.738 0.326 0.103 0.006 9000.0 0.314 34.017 1.790 951.147 0.060 0.005 2.837 0.356 0.117 0.007 9500.0 0.313 33.535 1.876 950.883 0.065 0.005 2.931 0.385 0.130 0.009 10000.0 0.311 33.057 1.962 950.621 0.070 0.006 3.020 0.415 0.144 0.010 10500.0 0.309 32.584 2.046 950.359 0.075 0.006 3.105 0.446 0.159 0.012 11000.0 0.307 32.114 2.129 950.099 0.079 0.007 3.184 0.476 0.174 0.014 11500.0 0.305 31.648 2.210 949.839 0.084 0.008 3.259 0.507 0.189 0.016 12000.0 0.304 31.186 2.291 949.579 0.090 0.009 3.330 0.539 0.204 0.018 12500.0 0.302 30.728 2.371 949.320 0.095 0.010 3.398 0.570 0.220 0.020 13000.0 0.300 30.273 2.450 949.061 0.100 0.011 3.461 0.602 0.235 0.023 13500.0 0.299 29.822 2.528 948.802 0.105 0.011 3.521 0.633 0.252 0.026 14000.0 0.297 29.375 2.605 948.543 0.111 0.012 3.578 0.665 0.268 0.028 14500.0 0.295 28.931 2.682 948.283 0.116 0.014 3.633 0.697 0.284 0.031 15000.0 0.293 28.491 2.757 948.023 0.121 0.015 3.684 0.729 0.301 0.035 15500.0 0.292 28.055 2.831 947.762 0.127 0.016 3.733 0.761 0.318 0.038 16000.0 0.290 27.622 2.905 947.500 0.133 0.017 3.780 0.793 0.335 0.042 16500.0 0.288 27.193 2.978 947.236 0.138 0.018 3.824 0.825 0.352 0.046 17500.0 0.285 26.346 3.121 946.706 0.150 0.021 3.907 0.889 0.386 0.054 20000.0 0,277 24.291 3.464 945.359 0.180 0.029 4.080 1.049 0.474 0.078 22500.0 0.268 22.325 3.786 943.979 0.213 0.038 4.211 1.206 0.562 0.108 25000.0 0.260 20.447 4.087 942.563 0.246 0.050 4.305 1.361 0.647 0.143 27500.0 0.252 18.656 4.368 941.111 0.281 0.063 4.367 1.511 0.729 0.183 30000.0 0,244 16.952 4.629 939.620 0.317 0.078 4.403 1.657 0.805 0.230 32500.0 0,235 15.335 4.870 938.087 0.353 0.094 4.416 1.797 0.876 0.282 35000.0 0,227 13.806 5.092 936.510 0.389 0.113 4.409 1.930 0.940 0.339 37500.0 0,219 12.364 5.293 934.887 0.425 0.134 4.386 2.055 0.998 0.402 40000.0 0,211 11.010 5.475 933.215 0.461 0.156 4.350 2.173 1.049 0.470 42500.0 0,203 9.745 5.637 931.492 0.497 0.180 4.303 2.282 1.093 0.542 45000.0 0.195 8.570 5.779 929.715 0.531 0.205 4.249 2.382 1.131 0.620 47500.0 0.187 7.485 5.902 927.881 0.565 0.231 4.189 2.473 1.162 0.702 50000.0 0,180 6.491 6.005 925.990 0.597 0.257 4.126 2.555 1.186 0.788 52500.0 0.172 5.587 6.089 924.038 0.628 0.284 4.061 2.627 1.206 0.878 55000.0 0,164 4.773 6.154 922.026 0.657 0.312 3.996 2.690 1.219 0.971 57500.0 0.157 4.045 6.201 919.954 0.685 0.339 3.933 2.743 1.229 1.067 60000.0 0.150 3.402 6.230 917.821 0.710 0.365 3.873 2.788 1.234 1.165 62500.0 0.143 2.840 6.243 915.630 0.733 0.390 3.816 2.825 1.236 1.264 65000.0 0,136 2.353 6.240 913.384 0.754 0.414 3.764 2.855 1.236 1.365 67500.0 0.129 1.937 6.223 911.085 0.773 0.436 3.716 2.877 1.234 1.466 70000.0 0.123 1.585 6.194 908.739 0.789 0.457 3.673 2.894 1.230 1.567 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-25 Table C.24 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/bMTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 43.648 0.000 956.003 0.000 0.000 0.000 0.000 0.000 0.000 0.0 0.349 43.529 0.024 955.939 0.000 0.000 0.023 0.000 0.000 0.000 100.0 0.349 500.0 0.347 43.056 0.119 955.681 0.002 0.000 0.227 0.002 0.000 0.000 1000.0 0.344 42.474 0.237 955.359 0.005 0.000 0.490 0.008 0.000 0.000 1500.0 0.342 41.902 0.351 955.037 0.007 0.000 0.740 0.018 0.002 0.000 2000.0 0.340 41.340 0.464 954.716 0.010 0.000 0.977 0.031 0.004 0.000 2500.0 0.337 40.786 0.574 954.397 0.014 0.000 1.203 0.047 0.007 0.000 3000.0 0.335 40.241 0.683 954.077 0.017 0.001 1.418 0.065 0.011 0.000 3500.0 0.333 39.703 0.789 953.759 0.021 0.001 1.623 0.085 0.017 0.000 4000.0 0.330 39.173 0.894 953.441 0.025 0.001 1.819 0.107 0.023 0.001 4500.0 0.328 38.651 0.997 953.124 0.029 0.001 2.005 0.130 0.031 0.001 5000.0 0.326 38.135 1.098 952.808 0.034 0.002 2.182 0.155 0.041 0.001 5500.0 0.324 37.626 1.197 952.492 0.039 0.002 2.351 0.181 0.051 0.002 6000.0 0.322 37.123 1.295 952.178 0.043 0.003 2.513 0.208 0.062 0.002 6500.0 0.319 36.626 1.392 951.864 0.048 0.003 2.666 0.236 0.075 0.003 7000.0 0.317 36.135 1.486 951.550 0.054 0.004 2.813 0.264 0.088 0.004 7500.0 0.315 35.650 1.580 951.238 0.059 0.004 2.953 0.294 0.102 0.005 8000.0 0.313 35.171 1.671 950.926 0.065 0.005 3.086 0.324 0.117 0.006 8500.0 0.311 34.696 1.762 950.615 0.070 0.006 3.213 0.354 0.132 0.007 9000.0 0.309 34.227 1.851 950.305 0.076 0.007 3.334 0.386 0.148 0.009 9500.0 0.307 33.763 1.939 949.996 0.082 0.008 3.449 0.417 0.165 0.011 10000.0 0.305 33.303 2.025 949.688 0.088 0.008 3.558 0.449 0.182 0.012 10500.0 0.303 32.848 2.110 949.380 0.094 0.009 3.662 0.482 0.200 0.014 11000.0 0.301 32.397 2.194 949.073 0.100 0.011 3.761 0.515 0.218 0.016 11500.0 0.299 31.951 2.277 948.768 0.106 0.012 3.854 0.548 0.236 0.019 12000.0 0.297 31.509 2.359 948.463 0.112 0.013 3.944 0.582 0.254 0.021 12500.0 0.295 31.071 2.439 948.158 0.119 0.014 4.028 0.616 0.273 0.024 13000.0 0.293 30.637 2.519 947.854 0.125 0.015 4.109 0.650 0.292 0.027 13500.0 0.291 30.207 2.597 947.550 0.132 0.017 4.186 0.684 0.311 0.030 14000.0 0.289 29.781 2.674 947.247 0.138 0.018 4.259 0.718 0.330 0.033 14500.0 0.287 29.358 2.751 946.943 0.145 0.020 4.329 0.753 0.350 0.036 15000.0 0.285 28.940 2.826 946.639 0.151 0.021 4.396 0.787 0.369 0.040 15500.0 0.284 28.525 2.900 946.334 0.158 0.023 4.459 0.822 0.389 0.044 16000.0 0.282 28.114 2.974 946.029 0.165 0.025 4.520 0.856 0.409 0.047 16500.0 0.280 27.707 3.046 945.724 0.172 0.026 4.579 0.891 0.429 0.052 17000.0 0.278 27.304 3.117 945.417 0.179 0.028 4.635 0.926 0.449 0.056 17500.0 0.276 26.904 3.188 945.109 0.186 0.030 4.688 0.961 0.469 0.060 18000.0 0.274 26.508 3.257 944.801 0.193 0.032 4.739 0.995 0.489 0.065 18500.0 0.272 26.116 3.326 944.491 0.201 0.034 4.789 1.030 0.509 0.070 19000.0 0.271 25.728 3.394 944.180 0.208 0.037 4.836 1.065 0.530 0.075 20000.0 0.267 24.962 3.527 943.554 0.223 0.041 4.925 1.134 0.570 0.086 22500.0 0.258 23.110 3.843 941.969 0.260 0.054 5.115 1.305 0.672 0.116 25000.0 0.249 21.347 4.138 940.351 0.299 0.070 5.266 1.473 0.772 0.152 27500.0 0.241 19.670 4.412 938.700 0.339 0.087 5.383 1.638 0.868 0.192 30000.0 0.232 18.078 4.666 937.015 0.379 0.107 5.469 1.798 0.960 0.237 32500.0 0.224 16.569 4.899 935.295 0.419 0.130 5.529 1.952 1.047 0.287 35000.0 0.216 15.142 5.113 933.539 0.459 0.154 5.566 2.101 1.127 0.341 37500.0 0.207 13.795 5.307 931.747 0.499 0.181 5.583 2.242 1.202 0.399 40000.0 0.200 12.528 5.481 929.916 0.539 0.209 5.584 2.377 1.271 0.461 42500.0 0.192 11.339 5.637 928.047 0.578 0.240 5.571 2.503 1.333 0.527 45000.0 0.184 10.227 5.775 926.139 0.615 0.272 5.547 2.622 1.388 0.597 47500.0 0.177 9.190 5.895 924.190 0.652 0.305 5.513 2.733 1.438 0.670 50000.0 0.170 8.228 5.997 922.201 0.688 0.340 5.472 2.835 1.481 0.746 52500.0 0.163 7.339 6.082 920.172 0.722 0.375 5.425 2.929 1.518 0.824 55000.0 0.156 6.521 6.152 918.103 0.754 0.411 5.374 3.014 1.550 0.905 57500.0 0.150 5.771 6.205 915.993 0.784 0.446 5.320 3.091 1.577 0.989 60000.0 0.144 5.087 6.244 913.843 0.812 0.482 5.266 3.159 1.599 1.074 62500.0 0.138 4.468 6.269 911.656 0.839 0.517 5.211 3.220 1.616 1.161 65000.0 0.132 3.909 6.280 909.430 0.863 0.552 5.156 3.273 1.630 1.249 67500.0 0.126 3.407 6.278 907.169 0.885 0.585 5.104 3.319 1.640 1.339 70000.0 0.121 2.960 6.265 904.874 0.904 0.617 5.053 3.358 1.648 1.429 AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-26 Table C.25 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.151 0.000 956.504 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.345 43.031 0.022 956.452 0.000 0.000 0.020 0.000 0.000 0.000 500.0 0.343 42.554 0.111 956.243 0.002 0.000 0.193 0.002 0.000 0.000 1000.0 0.341 41.966 0.221 955.980 0.003 0.000 0.410 0.007 0.000 0.000 1500.0 0.339 41.387 0.329 955.718 0.005 0.000 0.616 0.015 0.001 0.000 2000.0 0.337 40.816 0.434 955.455 0.008 0.000 0.813 0.027 0.002 0.000 2500.0 0.336 40.253 0.539 955.191 0.010 0.000 1.001 0.041 0.004 0.000 3000.0 0.334 39.697 0.641 954.928 0.013 0.000 1.180 0.057 0.007 0.000 3500.0 0.332 39.148 0.742 954.664 0.016 0.000 1.350 0.075 0.011 0.000 4000.0 0.330 38.606 0.842 954.400 0.019 0.001 1.513 0.095 0.016 0.000 4500.0 0.328 38.071 0.940 954.136 0.022 0.001 1.668 0.117 0.022 0.001 5000.0 0.326 37.542 1.037 953.872 0.025 0.001 1.816 0.139 0.029 0.001 5500.0 0.324 37.019 1.132 953.607 0.029 0.001 1.958 0.163 0.036 0.001 6000.0 0.322 36.502 1.226 953.342 0.033 0.002 2.093 0.188 0.045 0.002 6500.0 0.321 35.990 1.319 953.077 0.036 0.002 2.221 0.214 0.054 0.003 7000.0 0.319 35.484 1.411 952.812 0.040 0.002 2.344 0.241 0.065 0.003 7500.0 0.317 34.983 1.501 952.546 0.044 0.003 2.461 0.268 0.076 0.004 8000.0 0.315 34.488 1.590 952.280 0.049 0.003 2.572 0.297 0.087 0.005 8500.0 0.313 33.998 1.678 952.014 0.053 0.004 2.679 0.325 0.100 0.006 9000.0 0.312 33.512 1.765 951.748 0.057 0.004 2.780 0.355 0.113 0.008 9500.0 0.310 33.031 1.850 951.482 0.062 0.005 2.876 0.384 0.127 0.009 10000.0 0.308 32.556 1.935 951.216 0.067 0.005 2.968 0.414 0.141 0.011 10500.0 0.306 32.084 2.018 950.949 0.071 0.006 3.055 0.445 0.155 0.013 11000.0 0.304 31.617 2.101 950.683 0.076 0.007 3.137 0.476 0.170 0.015 11500.0 0.303 31.154 2.182 950.416 0.081 0.008 3.216 0.507 0.186 0.017 12000.0 0.301 30.696 2.262 950.150 0.086 0.008 3.290 0.539 0.202 0.019 12500.0 0.299 30.242 2.341 949.883 0.092 0.009 3.361 0.570 0.218 0.022 13000.0 0.298 29.792 2.419 949.616 0.097 0.010 3.427 0.602 0.234 0.024 13500.0 0.296 29.345 2.497 949.350 0.102 0.011 3.490 0.635 0.251 0.027 14000.0 0.294 28.903 2.573 949.083 0.108 0.012 3.550 0.667 0.267 0.030 14500.0 0.292 28.464 2.648 948.816 0.113 0.013 3.605 0.699 0.284 0.034 15000.0 0.291 28.029 2.723 948.550 0.119 0.014 3.658 0.732 0.301 0.037 15500.0 0.289 27.597 2.796 948.284 0.124 0.015 3.707 0.764 0.318 0.041 16000.0 0.287 27.169 2.869 948.018 0.130 0.017 3.753 0.797 0.335 0.045 16500.0 0.286 26.745 2.940 947.751 0.136 0.018 3.797 0.830 0.352 0.049 17000.0 0.284 26.324 3.011 947.485 0.141 0.019 3.837 0.862 0.369 0.053 17500.0 0.282 25.906 3.081 947.218 0.147 0.021 3.875 0.895 0.386 0.057 18000.0 0.281 25.492 3.150 946.951 0.153 0.022 3.911 0.927 0.403 0.062 18500.0 0.279 25.080 3.219 946.683 0.159 0.023 3.944 0.960 0.420 0.067 19000.0 0.277 24.673 3.286 946.415 0.165 0.025 3.976 0.992 0.437 0.072 19500.0 0.276 24.269 3.353 946.145 0.171 0.027 4.005 1.025 0.454 0.078 20000.0 0.274 23.868 3.419 945.874 0.177 0.028 4.033 1.057 0.471 0.083 20500.0 0.272 23.471 3.484 945.602 0.183 0.030 4.059 1.089 0.488 0.089 22500.0 0.266 21.917 3.736 944.500 0.208 0.038 4.149 1.215 0.556 0.114 25000.0 0.258 20.054 4.033 943.089 0.240 0.049 4.231 1.369 0.639 0.151 27500.0 0.250 18.278 4.310 941.639 0.274 0.062 4.283 1.518 0.718 0.193 30000.0 0.242 16.590 4.567 940.148 0.308 0.076 4.311 1.661 0.792 0.242 32500.0 0.233 14.989 4.804 938.614 0.343 0.093 4.317 1.797 0.861 0.296 35000.0 0.225 13.475 5.022 937.034 0.379 0.112 4.305 1.926 0.923 0.355 37500.0 0.217 12.050 5.219 935.407 0.414 0.132 4.278 2.048 0.979 0.420 40000.0 0.210 10.714 5.397 933.728 0.450 0.154 4.240 2.161 1.027 0.491 42500.0 0.202 9.468 5.555 931.997 0.485 0.177 4.192 2.265 1.069 0.566 45000.0 0.194 8.312 5.694 930.210 0.519 0.202 4.137 2.361 1.105 0.646 47500.0 0.186 7.247 5.813 928.365 0.552 0.227 4.078 2.447 1.134 0.730 50000.0 0.178 6.273 5.913 926.461 0.584 0.253 4.016 2.524 1.156 0.819 52500.0 0.171 5.389 5.993 924.496 0.615 0.280 3.953 2.591 1.174 0.911 55000.0 0.163 4.594 6.055 922.470 0.643 0.306 3.891 2.650 1.187 1.006 57500.0 0.156 3.886 6.099 920.382 0.670 0.332 3.830 2.700 1.195 1.104 60000.0 0.149 3.262 6.126 918.234 0.695 0.358 3.773 2.741 1.199 1.203 62500.0 0.142 2.718 6.137 916.028 0.718 0.382 3.719 2.775 1.201 1.304 65000.0 0.135 2.248 6.132 913.766 0.739 0.405 3.669 2.802 1.200 1.406 67500.0 0.129 1.848 6.115 911.453 0.757 0.426 3.624 2.822 1.197 1.508 70000.0 0.122 1.509 6.085 909.093 0.773 0.445 3.584 2.837 1.193 1.609 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-27 Table C.26 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 u-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.151 0.000 856.504 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.345 43.031 0.023 856.445 0.000 0.000 0.023 0.000 0.000 0.000 500.0 0.343 42.556 0.115 956.208 0.002 0.000 0.217 0.002 0.000 0.000 1000.0 0.341 41.972 0.229 955.910 0.004 0.000 0.462 0.008 0.000 0.000 1500.0 0.339 41.397 0.340 955.612 0.006 0.000 0.694 0.017 0.001 0.000 2000.0 0.337 40.832 0.449 955.314 0.009 0.000 0.916 0.030 0.003 0.000 2500.0 0.334 40.275 0.556 955.016 0.012 0.000 1.127 0.046 0.006 0.000 3000.0 0.332 39.726 0.662 954.718 0.015 0.000 1.328 0.063 0.010 0.000 3500.0 0.330 39.185 0.766 954.420 0.019 0.001 1.520 0.083 0.015 0.000 4000.0 0.328 38.652 0.868 954.121 0.022 0.001 1.704 0.105 0.021 0.001 4500.0 0.326 38.125 0.968 953.823 0.026 0.001 1.879 0.128 0.028 0.001 5000.0 0.324 37.606 1.067 953.524 0.030 0.001 2.046 0.152 0.036 0.001 5500.0 0.322 37.093 1.164 953.225 0.034 0.002 2.206 0.178 0.046 0.002 6000.0 0.320 36.586 1.260 952.926 0.039 0.002 2.359 0.204 0.056 0.002 6500.0 0.318 36.086 1.354 952.627 0.043 0.003 2.505 0.232 0.067 0.003 7000.0 0.316 35.591 1.447 952.327 0.048 0.003 2.644 0.260 0.080 0.004 7500.0 0.314 35.103 1.539 952.028 0.053 0.004 2.777 0.289 0.093 0.005 8000.0 0.312 34.620 1.629 951.729 0.058 0.004 2.905 0.319 0.107 0.006 8500.0 0.310 34.142 1.718 951.429 0.063 0.005 3.026 0.350 0.122 0.008 9000.0 0.308 33.670 1.805 951.129 0.068 0.006 3.142 0.380 0.137 0.009 9500.0 0.306 33.203 1.891 950.830 0.073 0.006 3.253 0.412 0.153 0.011 10000.0 0.304 32.741 1.976 950.530 0.079 0.007 3.359 0.444 0.170 0.013 10500.0 0.302 32.284 2.060 950.230 0.085 0.008 3.459 0.476 0.187 0.015 11000.0 0.300 31.831 2.143 949.930 0.090 0.009 3.555 0.508 0.205 0.017 11500.0 0.298 31.384 2.224 949.630 0.096 0.010 3.647 0.541 0.223 0.019 12000.0 0.296 30.940 2.304 949.331 0.102 0.011 3.734 0.574 0.241 0.022 12500.0 0.294 30.502 2.384 949.031 0.108 0.012 3.817 0.608 0.260 0.025 13000.0 0.293 30.067 2.462 948.731 0.115 0.013 3.896 0.641 0.278 0.028 13500.0 0.291 29.637 2.539 948.432 0.121 0.014 3.970 0.675 0.298 0.031 14000.0 0.289 29.211 2.615 948.132 0.127 0.016 4.041 0.709 0.317 0.034 14500.0 0.287 28.789 2.690 947.833 0.133 0.017 4.108 0.743 0.336 0.038 15000.0 0.285 28.370 2.764 947.534 0.140 0.019 4.172 0.777 0.356 0.042 15500.0 0.283 27.956 2.837 947.235 0.146 0.020 4.232 0.811 0.375 0.046 16000.0 0.282 27.545 2.909 946.936 0.153 0.022 4.289 0.846 0.395 0.050 16500.0 0.280 27.138 2.980 946.637 0.159 0.023 4.342 0.880 0.414 0.054 17000.0 0.278 26.735 3.050 946.338 0.166 0.025 4.393 0.914 0.434 0.059 17500.0 0.276 26.334 3.119 946.040 0.173 0.027 4.440 0.949 0.453 0.064 18000.0 0.274 25.938 3.188 945.740 0.179 0.029 4.485 0.983 0.473 0.069 18500.0 0.273 25.545 3.255 945.441 0.186 0.030 4.528 1.017 0.492 0.074 19000.0 0.271 25.155 3.322 945.141 0.193 0.032 4.568 1.051 0.512 0.080 19500.0 0.269 24.769 3.387 944.840 0.200 0.034 4.606 1.085 0.531 0.085 20000.0 0.267 24.386 3.452 944.539 0.207 0.037 4.642 1.119 0.550 0.091 20500.0 0.266 24.007 3.516 944.236 0.214 0.039 4.676 1.153 0.570 0.097 21000.0 0.264 23.632 3.579 943.933 0.221 0.041 4.709 1.187 0.589 0.104 21500.0 0.262 23.260 3.641 943.628 0.228 0.043 4.739 1.220 0.608 0.110 22000.0 0.261 22.891 3.703 943.322 0.235 0.046 4.768 1.253 0.627 0.117 22500.0 0.259 22.526 3.763 943.015 0.242 0.048 4.796 1.287 0.646 0.124 25000.0 0.250 20.753 4.054 941.457 0.279 0.062 4.913 1.449 0.740 0.162 27500.0 0.242 19.066 4.323 939.865 0.316 0.078 4.999 1.606 0.831 0.205 30000.0 0.234 17.464 4.573 938.236 0.355 0.096 5.058 1.756 0.917 0.253 32500.0 0.226 15.947 4.803 936.569 0.393 0.117 5.093 1.901 0.997 0.307 35000.0 0.218 14.512 5.013 934.863 0.432 0.139 5.108 2.038 1.071 0.365 37500.0 0.210 13.160 5.203 933.117 0.471 0.164 5.106 2.168 1.139 0.428 40000.0 0.202 11.888 5.376 931.330 0.509 0.190 5.089 2.290 1.199 0.495 42500.0 0.194 10.697 5.529 929.500 0.546 0.218 5.061 2.404 1.253 0.566 45000.0 0.187 9.586 5.664 927.627 0.582 0.247 5.024 2.510 1.301 0.641 47500.0 0.179 8.553 5.782 925.709 0.618 0.278 4.979 2.607 1.342 0.719 50000.0 0.172 7.597 5.882 923.746 0.652 0.309 4.929 2.696 1.376 0.801 52500.0 0.165 6.717 5.965 921.737 0.684 0.341 4.875 2.776 1.405 0.885 55000.0 0.159 5.912 6.032 919.683 0.715 0.374 4.819 2.847 1.429 0.971 57500.0 0.152 5.179 6.082 917.584 0.744 0.406 4.762 2.911 1.448 1.060 60000.0 0.146 4.516 6.118 915.440 0.772 0.438 4.705 2.966 1.462 1.150 62500.0 0.140 3.919 6.139 913.253 0.797 0.469 4.649 3.014 1.473 1.241 65000.0 0.134 3.386 6.146 911.023 0.820 0.499 4.596 3.055 1.480 1.333 67500.0 0.128 2.913 6.141 908.754 0.841 0.528 4.544 3.089 1.484 1.425 70000.0 0.122 2.495 6.125 906.447 0.860 0.555 4.496 3.118 1.486 1.518 AREVA NP Inc.
Lontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-28 Table C.27 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.151 0-000 956.504 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.345 43.032 0.024 956.436 0.000 0.000 0.026 0.000 0.000 0.000 500.0 0.343 42.561 0.121 956.161 0.002 0.000 0.248 0.002 0.000 0.000 1000.0 0.340 41.982 0.239 955.817 0.005 0.000 0.528 0.009 0.001 0.000 1500.0 0.338 41.414 0.355 955.473 0.008 0.000 0.794 0.019 0.002 0.000 2000.0 0.335 40.856 0.469 955.129 0.011 0.000 1.048 0.033 0.004 0.000 2500.0 0.333 40.308 0.580 954.786 0.015 0.000 1.290 0.050 0.008 0.000 3000.0 0.330 39.768 0.689 954.442 0.019 0.001 1.521 0.070 0.013 0.000 3500.0 0.328 39.237 0.797 954.098 0.023 0.001 1.742 0.091 0.019 0.000 4000.0 0.326 38.714 0.902 953.754 0.027 0.001 1.953 0.114 0.027 0.001 4500.0 0.323 38.199 1.006 953.410 0.032 0.002 2.156 0.138 0.036 0.001 5000.0 0.321 37.692 1.108 953.066 0.037 0.002 2.350 0.164 0.046 0.002 5500.0 0.318 37.191 1.208 952.722 0.042 0.002 2.535 0.191 0.057 0.002 6000.0 0.316 36.697 1.306 952.378 0.047 0.003 2.714 0.219 0.070 0.003 6500.0 0.314 36.210 1.403 952.034 0.053 0.004 2.885 0.248 0.084 0.004 7000.0 0.312 35.729 1.498 951.689 0.058 0.004 3.048 0.278 0.098 0.005 7500.0 0.309 35.255 1.591 951.345 0.064 0.005 3.206 0.309 0.114 0.006 8000.0 0.307 34.787 1.683 951.001 0.071 0.006 3.356 0.340 0.130 0.007 8500.0 0.305 34.324 1.774 950.656 0.077 0.007 3.501 0.372 0.148 0.009 9000.0 0.303 33.867 1.863 950.312 0.083 0.008 3.640 0.404 0.166 0.010 9500.0 0.300 33.415 1.951 949.968 0.090 0.009 3.773 0.437 0.184 0.012 10000.0 0.298 32.969 2.038 949.623 0.097 0.010 3.901 0.471 0.203 0.014 10500.0 0.296 32.528 2.123 949.279 0.103 0.011 4.023 0.505 0.223 0.016 11000.0 0.294 32.092 2.207 948.935 0.110 0.012 4.140 0.539 0.243 0.019 11500.0 0.292 31.661 2.289 948.590 0.117 0.014 4.253 0.574 0.264 0.021 12000.0 0.290 31.235 2.371 948.246 0.124 0.015 4.361 0.609 0.285 0.024 12500.0 0.288 30.814 2.451 947.902 0.132 0.017 4.464 0.644 0.306 0.027 13000.0 0.286 30.397 2.530 947.558 0.139 0.018 4.563 0.680 0.327 0.030 13500.0 0.284 29.984 2.607 947.214 0.146 0.020 4.657 0.716 0.349 0.034 14000.0 0.282 29.576 2.684 946.870 0.154 0.022 4.748 0.752 0.371 0.037 14500.0 0.279 29.173 2.759 946.526 0.161 0.024 4.834 0.788 0.393 0.041 15000.0 0.277 28.773 2.834 946.183 0.169 0.026 4.917 0.824 0.415 0.045 15500.0 0.275 28.377 2.907 945.839 0.176 0.028 4.996 0.861 0.437 0.049 16000.0 0.274 27.986 2.979 945.496 0.184 0.030 5.071 0.898 0.459 0.053 16500.0 0.272 27.598 3.050 945.153 0.192 0.032 5.143 0.935 0.482 0.058 17000.0 0.270 27.215 3.120 944.810 0.200 0.035 5.211 0.971 0.504 0.063 17500.0 0.268 26.834 3.189 944.467 0.208 0.037 5.276 1.008 0.526 0.068 18000.0 0.266 26.458 3.257 944.124 0.215 0.039 5.338 1.045 0.548 0.073 18500.0 0.264 26.085 3.324 943.781 0.223 0.042 5.398 1.082 0.570 0.078 19000.0 0.262 25.716 3.391 943.437 0.231 0.045 5.454 1.119 0.592 0.084 19500.0 0.260 25.350 3.456 943.094 0.239 0.047 5.509 1.156 0.614 0.089 20000.0 0.258 24.988 3.520 942.749 0.247 0.050 5.560 1.193 0.636 0.095 20500.0 0.256 24.630 3.583 942.404 0.255 0.053 5.610 1.230 0.657 0.101 21000.0 0.255 24.275 3.646 942.059 0.263 0.056 5.657 1.266 0.679 0.107 21500.0 0.253 23.923 3.707 941.712 0.271 0.059 5.703 1.303 0.701 0.114 22000.0 0.251 23.575 3.768 941.365 0.280 0.063 5.746 1.339 0.722 0.121 22500.0 0.249 23.230 3.828 941.017 0.288 0.066 5.788 1.376 0.744 0.127 23000.0 0.247 22.889 3.887 940.667 0.296 0.069 5.828 1.412 0.765 0.134 23500.0 0.245 22.551 3.945 940.317 0.304 0.073 5.867 1.448 0.787 0.141 24000.0 0.244 22.217 4.002 939.965 0.312 0.077 5.904 1.484 0.808 0.149 24500.0 0.242 21.886 4.058 939.612 0.320 0.080 5.939 1.519 0.829 0.156 25000.0 0.240 21.559 4.114 939.258 0.329 0.084 5.973 1.555 0.850 0.164 27500.0 0.231 19.972 4.379 937.468 0.370 0.105 6.124 1.729 0.954 0.205 30000.0 0.223 18.467 4.623 935.645 0.412 0.128 6.245 1.897 1.054 0.251 32500.0 0.215 17.043 4.848 933.790 0.454 0.154 6.340 2.060 1.150 0.300 35000.0 0.206 15.697 5.053 931.903 0.496 0.183 6.412 2.216 1.240 0.354 37500.0 0.199 14.428 5.239 929.982 0.538 0.213 6.464 2.366 1.324 0.411 40000.0 0.191 13.233 5.407 928.027 0.579 0.246 6.498 2.509 1.403 0.471 42500.0 0.184 12.111 5.556 926.040 0.618 0.281 6.518 2.645 1.476 0.534 45000.0 0.176 11.059 5.688 924.019 0.657 0.317 6.525 2.774 1.542 0.601 47500.0 0.170 10.075 5.804 921.964 0.695 0.356 6.521 2.895 1.603 0.670 50000.0 0.163 9.159 5.903 919.877 0.731 0.395 6.508 3.008 1.659 0.741 52500.0 0.157 8.306 5.987 917.758 0.766 0.435 6.488 3.114 1.709 0.815 55000.0 0.151 7.516 6.056 915.606 0.799 0.476 6.463 3.212 1.754 0.890 57500.0 0.145 6.785 6.111 913.423 0.830 0.518 6.432 3.302 1.793 0.968 60000.0 0.139 6.112 6.153 911.210 0.860 0.560 6.398 3.386 1.828 1.047 62500.0 0.134 5.493 6.182 908.968 0.887 0.601 6.362 3.462 1.859 1.128 65000.0 0.129 4.926 6.198 906.697 0.912 0.642 6.324 3.532 1.886 1.210 67500.0 0.124 4.409 6.204 904.400 0.936 0.682 6.286 3.594 1.909 1.293 70000.0 0.119 3.938 6.199 902.077 0.957 0.721 6.247 3.651 1.929 1.377 AREVA NP Inc.
Uontroiled Ulocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-29 Table C.28 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 43.092 0.000 956.563 0.000 0.000 0.000 0.000 0.000 0.0 0.345 42.972 0.022 956.510 0.000 0.000 0.021 0.000 0.000 0.000 100.0 0.344 0.000 500.0 0.343 42.496 0.112 956.297 0.002 0.000 0.196 0.002 0.000 0.000 1000.0 0.341 41.908 0.222 956.031 0.003 0.000 0.416 0.007 0.000 0.000 1500.0 0.339 41.330 0.329 955.765 0.006 0.000 0.625 0.016 0.001 0.000 2000.0 0.337 40.760 0.436 955.498 0.008 0.000 0.825 0.028 0.002 0.000 2500.0 0.335 40.198 0.540 955.231 0.010 0.000 1.014 0.042 0.005 0.000 3000.0 0.333 39.643 0.643 954.965 0.013 0.000 1.195 0.058 0.008 0.000 3500.0 0.331 39.095 0.744 954.698 0.016 0.001 1.367 0.077 0.012 0.000 4000.0 0.329 38.554 0.844 954.431 0.019 0.001 1.531 0.097 0.017 0.000 4500.0 0.327 38.020 0.942 954.164 0.022 0.001 1.687 0.119 0.023 0.001 5000.0 0.326 37.492 1.039 953.897 0.026 0.001 1.836 0.142 0.030 0.001 5500.0 0.324 36.970 1.134 953.630 0.029 0.001 1.978 0.166 0.038 0.002 6000.0 0.322 36.454 1.228 953.362 0.033 0.002 2.114 0.191 0.046 0.002 6500.0 0.320 35.944 1.321 953.095 0.037 0.002 2.243 0.218 0.056 0.003 7000.0 0.318 35.440 1.412 952.828 0.041 0.002 2.365 0.245 0.066 0.003 7500.0 0.316 34.940 1.502 952.561 0.045 0.003 2.482 0.272 0.078 0.004 8000.0 0.314 34.446 1.591 952.294 0.049 0.003 2.593 0.301 0.089 0.005 8500.0 0.313 33.957 1.679 952.027 0.054 0.004 2.699 0.330 0.102 0.007 9000.0 0.311 33.473 1.766 951.759 0.058 0.004 2.800 0.359 0.115 0.008 9500.0 0.309 32.994 1.851 951.493 0.063 0.005 2.895 0.389 0.129 0.009 10000.0 0.307 32.519 1.935 951.226 0.067 0.006 2.986 0.420 0.143 0.011 10500.0 0.306 32.049 2.019 950.959 0.072 0.006 3.072 0.450 0.158 0.013 11000.0 0.304 31.583 2.101 950.693 0.077 0.007 3.154 0.482 0.173 0.015 11500.0 0.302 31.121 2.182 950.426 0.082 0.008 3.231 0.513 0.189 0.017 12000.0 0.300 30.663 2.262 950.161 0.087 0.009 3.304 0.545 0.204 0.020 12500.0 0.299 30.210 2.341 949.895 0.092 0.009 3.373 0.576 0.220 0.022 13000.0 0.297 29.760 2.419 949.630 0.097 0.010 3.438 0.609 0.237 0.025 13500.0 0.295 29.314 2.496 949.365 0.103 0.011 3.499 0.641 0.253 0.028 14000.0 0.293 28.872 2.572 949.100 0.108 0.012 3.556 0.673 0.270 0.031 14500.0 0.292 28.433 2.647 948.835 0.113 0.013 3.610 0.706 0.286 0.034 15000.0 0.290 27.998 2.722 948.571 0.119 0.014 3.661 0.738 0.303 0.038 15500.0 0.288 27.566 2.795 948.307 0.124 0.016 3.709 0.771 0.320 0.041 16000.0 0.287 27.138 2.868 948.043 0.130 0.017 3.754 0.803 0.337 0.045 16500.0 0.285 26.713 2.939 947.778 0.136 0.018 3.796 0.836 0.353 0.049 17000.0 0.283 26.292 3.010 947.513 0.141 0.019 3.836 0.868 0.370 0.054 17500.0 0.282 25.874 3.080 947.247 0.147 0.021 3.873 0.901 0.387 0.058 18000.0 0.280 25.459 3.149 946.981 0.153 0.022 3.908 0.933 0.404 0.063 18500.0 0.278 25.048 3.217 946.713 0.159 0.024 3.942 0.966 0.421 0.068 19000.0 0.277 24.641 3.285 946.444 0.165 0.025 3.973 0.998 0.438 0.073 19500.0 0.275 24.237 3.351 946.175 0.171 0.027 4.003 1.030 0.455 0.078 20000.0 0.274 23.836 3.417 945.904 0.177 0.028 4.030 1.062 0.472 0.084 20500.0 0.272 23.440 3.482 945.631 0.183 0.030 4.057 1.094 0.489 0.090 21000.0 0.270 23.046 3.546 945.358 0.189 0.032 4.081 1.126 0.506 0.096 21500.0 0.269 22.656 3.610 945.083 0.195 0.034 4.104 1.158 0.523 0.102 22000.0 0.267 22.270 3.672 944.806 0.201 0.036 4.126 1.189 0.540 0.108 22500.0 0.265 21.887 3.734 944.529 0.208 0.038 4.146 1.221 0.557 0.115 25000.0 0.257 20.025 4.031 943.116 0.240 0.049 4.228 1.374 0.640 0.152 27500.0 0.249 18.252 4.307 941.665 0.274 0.062 4.281 1.522 0.719 0.195 30000.0 0.241 16.565 4.564 940.173 0.308 0.077 4.308 1.665 0.794 0.243 32500.0 0.233 14.966 4.801 938.637 0.343 0.093 4.314 1.801 0.862 0.297 35000.0 0.225 13.454 5.018 937.056 0.379 0.112 4.303 1.929 0.924 0.357 37500.0 0.217 12.031 5.215 935.427 0.414 0.132 4.276 2.050 0.980 0.422 40000.0 0.209 10.697 5.393 933.748 0.450 0.154 4.238 2.163 1.028 0.493 42500.0 0.201 9.453 5.551 932.015 0.485 0.177 4.190 2.267 1.070 0.568 45000.0 0.193 8.299 5.689 930.226 0.519 0.202 4.136 2.362 1.105 0.648 47500.0 0.186 7.236 5.808 928.380 0.552 0.227 4.076 2.448 1.134 0.733 50000.0 0.178 6.263 5.907 926.475 0.584 0.254 4.015 2.525 1.157 0.821 52500.0 0.171 5.381 5.987 924.508 0.614 0.280 3.952 2.593 1.174 0.913 55000.0 0.163 4.588 6.049 922.480 0.643 0.306 3.890 2.651 1.187 1.008 57500.0 0.156 3.881 6.093 920.392 0.670 0.332 3.829 2.701 1.195 1.106 60000.0 0.149 3.259 6.119 918.242 0.695 0.358 3.772 2.742 1.199 1.205 62500.0 0.142 2.715 6.130 916.035 0.718 0.382 3.718 2.776 1.201 1.306 65000.0 0.135 2.247 6.126 913.773 0.738 0.405 3.669 2.802 1.200 1.408 67500.0 0.128 1.846 6.108 911.460 0.756 0.426 3.624 2.823 1.197 1.510 70000.0 0.122 1.508 6.078 909.100 0.772 0.445 3.584 2.838 1.193 1.611 AREVA NP Inc.
Uontroiled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-30 Table C.29 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU 0-234 0-235 U-236 U-238 NP-237 PU-238 P0-239 PU-240 PU-241 PU-242 956.563 0.000 0.0 0.345 43.092 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.973 0.000 0.023 956.503 0.000 0.023 0.000 0.000 0.000 500.0 0.343 42.498 0.116 956.262 0.002 0.000 0.220 0.002 0.000 0.000 1000.0 0.340 41.914 0.230 955.960 0.004 0.000 0.468 0.008 0.000 0.000 1500.0 0.338 41.340 0.341 955.658 0.007 0.000 0.704 0.018 0.001 0.000 2000.0 0.336 40.775 0.450 955.356 0.009 0.000 0.928 0.031 0.003 0.000 2500.0 0.334 40.219 0.558 955.054 0.012 0.000 1.142 0.046 0.006 0.000 3000.0 0.332 39.672 0.664 954.752 0.016 0.000 1.345 0.065 0.010 0.000 3500.0 0.330 39.132 0.767 954.451 0.019 0.001 1.539 0.085 0.015 0.000 4000.0 0.327 38.599 0.870 954.149 0.023 0.001 1.724 0.107 0.021 0.001 4500.0 0.325 38.074 0.970 953.847 0.026 0.001 1.900 0.130 0.029 0.001 5000.0 0.323 37.556 1.069 953.546 0.031 0.001 2.069 0.155 0.037 0.001 5500.0 0.321 37.044 1.166 953.244 0.035 0.002 2.229 0.181 0.047 0.002 6000.0 0.319 36.539 1.262 952.943 0.039 0.002 2.383 0.207 0.057 0.002 6500.0 0.317 36.040 1.356 952.641 0.044 0.003 2.529 0.235 0.069 0.003 7000.0 0.315 35.547 1.449 952.340 0.048 0.003 2.669 0.264 0.082 0.004 7500.0 0.313 35.060 1.540 952.039 0.053 0.004 2.802 0.293 0.095 0.005 8000.0 0.311 34.578 1.630 951.738 0.058 0.004 2.929 0.323 0.109 0.006 8500.0 0.309 34.102 1.719 951.437 0.063 0.005 3.050 0.354 0.124 0.008 9000.0 0.307 33.631 1.806 951.136 0.069 0.006 3.166 0.385 0.140 0.009 9500.0 0.305 33.166 1.893 950.835 0.074 0.006 3.276 0.417 0.156 0.011 10000.0 0.303 32.705 1.977 950.535 0.080 0.007 3.380 0.449 0.173 0.013 10500.0 0.301 32.249 2.061 950.235 0.085 0.008 3.480 0.481 0.190 0.015 11000.0 0.299 31.798 2.143 949.935 0.091 0.009 3.575 0.514 0.208 0.017 11500.0 0.297 31.351 2.225 949.635 0.097 0.010 3.665 0.547 0.226 0.020 12000.0 0.296 30.909 2.305 949.336 0.103 0.011 3.751 0.580 0.244 0.022 12500.0 0.294 30.471 2.384 949.037 0.109 0.012 3.832 0.614 0.263 0.025 13000.0 0.292 30.037 2.462 948.738 0.115 0.013 3.909 0.648 0.282 0.028 13500.0 0.290 29.607 2.539 948.440 0.121 0.015 3.982 0.681 0.301 0.032 14000.0 0.288 29.181 2.614 948.142 0.128 0.016 4.051 0.715 0.320 0.035 14500.0 0.286 28.760 2.689 947.845 0.134 0.017 4.117 0.750 0.339 0.039 15000.0 0.285 28.342 2.763 947.548 0.140 0.019 4.178 0.784 0.358 0.042 15500.0 0.283 27.927 2.836 947.251 0.147 0.020 4.237 0.818 0.378 0.047 16000.0 0.281 27.516 2.908 946.954 0.153 0.022 4.292 0.852 0.397 0.051 16500.0 0.279 27.109 2.979 946.657 0.160 0.023 4.344 0.887 0.416 0.055 17000.0 0.277 26.705 3.049 946.360 0.166 0.025 4.393 0.921 0.436 0.060 17500.0 0.276 26.305 3.118 946.062 0.173 0.027 4.440 0.955 0.455 0.065 18000.0 0.274 25.909 3.186 945.764 0.179 0.029 4.484 0.989 0.474 0.070 18500.0 0.272 25.515 3.254 945.465 0.186 0.031 4.526 1.023 0.494 0.075 19000.0 0.270 25.126 3.320 945.166 0.193 0.033 4.566 1.057 0.513 0.081 19500.0 0.269 24.740 3.386 944.865 0.200 0.035 4.604 1.091 0.533 0.086 20000.0 0.267 24.358 3.451 944.564 0.207 0.037 4.640 1.125 0.552 0.092 20500.0 0.265 23.979 3.514 944.261 0.214 0.039 4.674 1.159 0.571 0.098 21000.0 0.263 23.603 3.577 943.958 0.221 0.041 4.706 1.192 0.590 0.105 21500.0 0.262 23.231 3.640 943.653 0.228 0.044 4.737 1.226 0.610 0.111 22000.0 0.260 22.863 3.701 943.347 0.235 0.046 4.766 1.259 0.629 0.118 22500.0 0.258 22.498 3.762 943.039 0.242 0.049 4.794 1.292 0.648 0.125 23000.0 0.257 22.137 3.821 942.730 0.249 0.051 4.820 1. 325 0.667 0.132 23500.0 0.255 21.779 3.880 942.420 0.257 0.054 4.845 1.357 0.686 0.139 25000.0 0.250 20.727 4.052 941.481 0.279 0.062 4.911 1.454 0.742 0.163 27500.0 0.241 19.042 4.321 939.888 0.316 0.078 4.997 1.610 0.832 0.206 30000.0 0.233 17.441 4.570 938.257 0.355 0.097 5.055 1.761 0.918 0.255 32500.0 0.225 15.926 4.799 936.589 0.393 0.117 5.091 1.905 0.999 0.308 35000.0 0.217 14.493 5.009 934.883 0.432 0.139 5.106 2.042 1.072 0.366 37500.0 0.209 13.142 5.200 933.136 0.471 0.164 5.104 2.171 1.140 0.429 40000.0 0.201 11.872 5.371 931.347 0.509 0.190 5.088 2.293 1.200 0.497 42500.0 0.194 10.682 5.525 929.516 0.546 0.218 5.060 2.407 1.254 0.568 45000.0 0.186 9.573 5.660 927.642 0.582 0.248 5.023 2.512 1.301 0.643 47500.0 0.179 8.541 5.777 925.723 0.618 0.278 4.978 2.609 1.342 0.721 50000.0 0.172 7.587 5.877 923.759 0.652 0.310 4.928 2.697 1.377 0.803 52500.0 0.165 6.709 5.959 921.749 0.684 0.342 4.874 2.777 1.406 0.887 55000.0 0.158 5.905 6.026 919.694 0.715 0.374 4.818 2.849 1.430 0.973 57500.0 0.152 5.173 6.076 917.594 0.744 0.406 4.761 2.912 1.448 1.062 60000.0 0.145 4.511 6.112 915.449 0.771 0.438 4.704 2.967 1.463 1.152 62500.0 0.139 3.915 6.133 913.261 0.797 0.469 4.649 3.015 1.473 1.243 65000.0 0.133 3.383 6.140 911.031 0.820 0.499 4.595 3.056 1.480 1.335 67500.0 0.128 2.910 6.135 908.761 0.841 0.528 4.544 3.090 1.484 1.427 70000.0 0.122 2.493 6.118 906.454 0.860 0.555 4.496 3.119 1.486 1.520 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-31 Table C.30 [ J Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 u-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.345 43.092 0.000 956.563 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.344 42.973 0.024 956.494 0.000 0.000 0.027 0.000 0.000 0.000 500.0 0.342 42.502 0.121 956.215 0.002 0.000 0.252 0.002 0.000 0.000 1000.0 0.340 41.924 0.240 955.966 0.005 0.000 0.535 0.009 0.001 0.000 1500.0 0.337 41.357 0.356 955.51: 0.008 0.000 0.805 0.020 0.002 0.000 2000.0 0.335 40.800 0.470 955.169 0.011 0.000 1.062 0.034 0.004 0.000 2500.0 0.332 40.252 0.582 954.821 0.015 0.000 1.306 0.051 0.008 0.000 3000.0 0.330 39.714 0.691 954.474 0.019 0.001 1.540 0.071 0.013 0.000 3500.0 0.327 39.184 0.799 954.126 0.023 0.001 1.763 0.092 0.019 0.000 4000.0 0.325 38.662 0.904 953.779 0.028 0.001 1.976 0.115 0.027 0.001 4500.0 0.322 38.148 1.008 953.431 0.032 0.002 2.180 0.140 0.037 0.001 5000.0 0.320 37.642 1.110 953.084 0.037 0.002 2.375 0.166 0.047 0.002 5500.0 0.318 37.143 1.210 952.738 0.042 0.003 2.562 0.194 0.059 0.002 6000.0 0.315 36.650 1.308 952.390 0.048 0.003 2.741 0.222 0.072 0.003 6500.0 0.313 36.165 1.405 952.044 0.053 0.004 2.913 0.251 0.086 0.004 7000.0 0.311 35.685 1.500 951.697 0.059 0.004 3.077 0.281 0.101 0.005 7500.0 0.309 35.212 1.594 951.351 0.065 0.005 3.234 0.312 0.116 0.006 8000.0 0.306 34.745 1.686 951.005 0.071 0.006 3.385 0.344 0.133 0.007 8500.0 0.304 34.284 1.776 950.659 0.078 0.007 3.530 0.376 0.151 0.009 9000.0 0.302 33.828 1.865 950.313 0.084 0.008 3.668 0.409 0.169 0.011 9500.0 0.300 33.378 1.953 949.968 0.091 0.009 3.801 0.442 0.187 0.012 10000.0 0.298 32.933 2.039 949.623 0.097 0.010 3.928 0.476 0.207 0.015 10500.0 0.295 32.494 2.124 949.278 0,104 0.011 4.049 0.510 0,227 0.017 11000.0 0.293 32.059 2.208 948.933 0.111 0.013 4.165 0.545 0.247 0.019 11500.0 0.291 31.629 2.290 948.588 0.118 0.014 4.277 0.579 0.267 0.022 12000.0 0.289 31.204 2.371 948.244 0.125 0.016 4.383 0.615 0.288 0.025 12500.0 0.287 30.784 2.451 947.900 0.132 0.017 4.485 0.650 0.310 0.028 13000.0 0.285 30.368 2.530 947.557 0.140 0.019 4.582 0.686 0.331 0.031 13500.0 0.283 29.956 2.607 947.214 0.147 0.020 4.675 0.722 0.353 0.034 14000.0 0.281 29.549 2.684 946.871 0.154 0.022 4.764 0.758 0.375 0.038 14500.0 0.279 29.146 2.759 946.529 0.162 0.024 4.849 0.795 0.396 0.042 15000.0 0.277 28.747 2.833 946.187 0.169 0.026 4.929 0.831 0.418 0.046 15500.0 0.275 28.351 2.906 945.845 0.177 0.028 5.006 0.868 0.440 0.050 16000.0 0.273 27.960 2.978 945.504 0.185 0.030 5.080 0.905 0.462 0.054 16500.0 0.271 27.573 3.049 945.163 0.192 0.032 5.150 0.942 0.484 0.059 17000.0 0.269 27.189 3.119 944.821 0.200 0.035 5.216 0.979 0.506 0.064 17500.0 0.267 26.809 3.188 944.480 0.208 0.037 5.280 1.016 0.528 0.069 18000.0 0.265 26.433 3.256 944.139 0.216 0.040 5.341 1.053 0.550 0.074 18500.0 0.263 26.060 3.323 943.797 0.224 0.042 5.400 1.090 0.572 0.079 19000.0 0.261 25.691 3.389 943.454 0.231 0.045 5.455 1.126 0.594 0.085 19500.0 0.260 25.325 3.454 943.111 0.239 0.048 5.509 1.163 0.616 0.090 20000.0 0.258 24.963 3.518 942.768 0.247 0.051 5.560 1.200 0.638 0.096 20500.0 0.256 24.604 3.582 942.424 0.255 0.053 5.609 1.237 0.659 0.102 21000.0 0.254 24.249 3.644 942.078 0.263 0.057 5.656 1.273 0.681 0.108 21500.0 0.252 23.898 3.706 941.732 0.271 0.060 5.701 1.309 0.703 0.115 22000.0 0.250 23.550 3.766 941.385 0.280 0.063 5.745 1.346 0.724 0.122 22500.0 0.249 23.206 3.826 941.037 0.288 0.066 5.787 1.382 0.746 0.128 23000.0 0.247 22.865 3.885 940.687 0.296 0.070 5.827 1.418 0.767 0.135 23500.0 0.245 22.527 3.943 940.336 0.304 0.073 5.865 1.454 0.789 0.143 24000.0 0.243 22.193 4.000 939.985 0.312 0.077 5.902 1.489 0.810 0.150 24500.0 0.241 21.863 4.056 939.632 0.321 0.081 5.938 1.525 0.831 0.157 25000.0 0.240 21.535 4.112 939.277 0.329 0.084 5.972 1.560 0.852 0.165 25500.0 0.238 21.212 4.166 938.922 0.337 0.088 6.005 1.596 0.873 0.173 26000.0 0.236 20.891 4.220 938.565 0.345 0.092 6.036 1.631 0.894 0.181 27500.0 0.231 19.950 4.376 937.487 0.370 0.105 6.123 1.734 0.956 0.206 30000.0 0.222 18.447 4.620 935.664 0.412 0.129 6.244 1.902 1.056 0.252 32500.0 0.214 17.024 4.845 933.807 0.454 0.155 6.339 2.064 1.151 0.302 35000.0 0.206 15.680 5.049 931.919 0.496 0.183 6.411 2.220 1.242 0.355 37500.0 0.198 14.412 5.235 929.997 0.538 0.214 6.463 2.370 1.326 0.412 40000.0 0.191 13.218 5.402 928.042 0.578 0.246 6.497 2.513 1.405 0.472 42500.0 0.183 12.097 5.552 926.053 0.618 0.281 6.517 2.648 1.477 0.536 45000.0 0.176 11.046 5.684 924.031 0.657 0.318 6.524 2.776 1.544 0.602 47500.0 0.169 10.064 5.799 921.976 0.695 0.356 6.521 2.897 1.605 0.671 50000.0 0.163 9.149 5.898 919.888 0.731 0.395 6.508 3.010 1.660 0.743 52500.0 0.156 8.298 5.982 917.768 0.766 0.436 6.488 3.115 1.710 0.817 55000.0 0.150 7.508 6.051 915.616 0.799 0.477 6.463 3.213 1.755 0.892 57500.0 0.144 6.779 6.105 913.432 0.830 0.518 6.432 3.304 1.794 0.970 60000.0 0.139 6.106 6.147 911.219 0.859 0.560 6.399 3.387 1.829 1.049 62500.0 0.133 5.488 6.175 908.976 0.886 0.601 6.363 3.463 1.860 1.129 65000.0 0.128 4.922 6.192 906.705 0.912 0.642 6.325 3.532 1.887 1.211 67500.0 0.124 4.405 6.198 904.407 0.935 0.682 6.286 3.595 1.910 1.294 70000.0 0.119 3.935 6.193 902.084 0.956 0.721 6.247 3.652 1.930 1.378 AREVA NP Inc.
Lontronled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page C-32 Table C.31 ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 P0-240 PU-241 PU-242 0.000 0.000 0.000 0.0 0.349 43.636 0.000 956.015 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.516 0.022 955.968 0.000 0.000 0.017 0.001 0.000 0.000 500.0 0.347 43.038 0.109 955.777 0.001 0.000 0.171 0.006 0.000 0.000 1000.0 0.345 42.448 0.217 955.539 0.003 0.000 0.369 0.013 0.001 0.000 1500.0 0.344 41.865 0.323 955.300 0.005 0.000 0.558 0.024 0.002 0.000 2000.0 0.342 41.290 0.427 955.061 0.007 0.000 0.738 0.036 0.004 0.000 2500.0 0.340 40.722 0.530 954.822 0.009 0.000 0.910 0.051 0.006 0.000 3000.0 0.338 40.160 0.632 954.583 0.012 0.000 1.074 0.067 0.009 0.000 3500.0 0.337 39.604 0.732 954.343 0.014 0.000 1.230 0.085 0.013 0.000 4000.0 0.335 39.055 0.831 954.104 0.017 0.001 1.379 0.105 0.018 0.001 4500.0 0.333 38.512 0.928 953.864 0.020 0.001 1.521 0.126 0.023 0.001 5000.0 0.331 37.974 1.024 953.625 0.023 0.001 1.656 0.148 0.030 0.001 5500.0 0.330 37.442 1.119 953.385 0.026 0.001 1.785 0.171 0.037 0.002 6000.0 0.328 36.916 1.213 953.146 0.029 0.001 1.908 0.195 0.045 0.002 6500.0 0.326 36.394 1.306 952.907 0.033 0.002 2.025 0.220 0.053 0.003 7000.0 0.324 35.877 1.397 952.667 0.036 0.002 2.136 0.246 0.063 0.003 7500.0 0.323 35.366 1.487 952.428 0.040 0.002 2.242 0.272 0.073 0.004 8000.0 0.321 34.858 1.576 952.189 0.043 0.003 2.343 0.299 0.083 0.005 8500.0 0.319 34.356 1.664 951.949 0.047 0.003 2.438 9000.0 0.318 33.858 1.751 951.710 0.051 0.004 2.529 0.326 0.094 0.006 9500.0 0.316 33.364 1.837 951.471 0.055 0.004 2.615 0.354 0.106 0.007 10000.0 0.314 32.875 1.922 951.232 0.059 0.004 2.697 0.383 0.118 0.009 10500.0 0.313 32.390 2.006 950.994 0.064 0.005 2.774 0.412 0.131 0.010 11000.0 0.311 31.908 2.089 950.755 0.068 0.006 2.847 0.441 0.144 0.012 11500.0 0.309 31.431 2.171 950.517 0.072 0.006 2.916 0.471 0.157 0.014 12000.0 0.308 30.957 2.252 950.279 0.077 0.007 2.981 0.501 0.171 0.016 12500.0 0.306 30.487 2.332 950.041 0.081 0.008 3.042 0.531 0.185 0.018 13000.0 0.304 30.021 2.411 949.803 0.086 0.008 3.099 0.561 0.199 0.020 13500.0 0.303 29.558 2.489 949.566 0.090 0.009 3.153 0.592 0.213 0.022 14000.0 0.301 29.099 2.567 949.330 0.095 0.010 3.203 0.622 0.227 0.025 14500.0 0.300 28.642 2.643 949.093 0.100 0.011 3.250 0.653 0.242 0.028 15000.0 0.298 28.190 2.719 948.857 0.105 0.012 3.294 0.684 0.256 0.031 15500.0 0.296 27.740 2.794 948.621 0.110 0.012 3.335 0.715 0.271 0.034 16000.0 0.295 27.293 2.868 948.385 0.114 0.013 3.373 0.746 0.285 0.037 16500.0 0.293 26.850 2.941 948.149 0.119 0.014 3.409 0.778 0.300 0.041 17000.0 0.292 26.410 3.013 947.912 0.124 0.015 3.442 0.809 0.315 0.044 17500.0 0.290 25.973 3.085 947.675 0.129 0.017 3.473 0.840 0.330 0.048 18000.0 0.289 25.539 3.156 947.437 0.135 0.018 3.503 0.871 0.345 0.052 18500.0 0.287 25.109 3.226 947.197 0.140 0.019 3.530 0.902 0.360 0.057 19000.0 0.285 24.682 3.296 946.957 0.145 0.020 3.556 0.933 0.375 0.061 20000.0 0.282 23.838 3.432 946.472 0.156 0.023 3.602 0.995 0.405 0.071 22500.0 0.274 21.787 3.760 945.234 0.183 0.030 3.694 1.147 0.480 0.098 25000.0 0.267 19.822 4.069 943.958 0.212 0.039 3.754 1.296 0.554 0.132 27500.0 0.259 17.943 4.358 942.642 0.243 0.050 3.786 1.440 0.625 0.171 30000.0 0.251 16.152 4.627 941.281 0.274 0.062 3.794 1.580 0.691 0.216 32500.0 0.243 14.450 4.878 939.873 0.306 0.075 3.784 1.713 0.751 0.268 35000.0 0.234 12.840 5.108 938.413 0.338 0.091 3.756 1.840 0.806 0.325 37500.0 0.226 11.324 5.317 936.898 0.371 0.108 3.716 1.959 0.853 0.389 40000.0 0.218 9.905 5.506 935.322 0.404 0.126 3.666 2.070 0.895 0.459 42500.0 0.210 8.587 5.674 933.682 0.437 0.146 3.608 2.172 0.929 0.535 45000.0 0.202 7.372 5.820 931.972 0.469 0.166 3.546 2.265 0.957 0.617 47500.0 0.193 6.263 5.944 930.188 0.500 0.188 3.481 2.347 0.979 0.705 50000.0 0.185 5.262 6.047 928.328 0.530 0.210 3.415 2.420 0.995 0.798 52500.0 0.176 4.370 6.127 926.388 0.559 0.233 3.351 2.483 1.007 0.896 55000.0 0.168 3.587 6.185 924.367 0.585 0.255 3.290 2.536 1.013 0.998 57500.0 0.160 2.909 6.223 922.265 0.610 0.276 3.233 2.579 1.017 1.103 60000.0 0.152 2.333 6.241 920.085 0.633 0.297 3.182 2.614 1.017 1.211 62500.0 0.144 1.850 6.241 917.832 0.654 0.317 3.136 2.640 1.015 1.321 65000.0 0.136 1.453 6.224 915.511 0.672 0.334 3.095 2.660 1.012 1.432 67500.0 0.128 1.132 6.194 913.130 0.687 0.351 3.061 2.673 1.008 1.543 70000.0 0.121 0.875 6.151 910.698 0.701 0.365 3.031 2.682 1.003 1.653 AREVA NP Inc.
Uontrolled uocument MirIaor Fi m, nmcinn Pmonnrt ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-33 Table C.32 [ ] Exposure-Dependent 40% Void Isotopics (kgIMTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.636 0.000 956.015 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.516 0.023 955.961 0.000 0.000 0.019 0.000 0.000 0.000 500.0 0.347 43.040 0.113 955.743 0.002 0.000 0.194 0.001 0.000 0.000 1000.0 0.345 42.453 0.225 955.469 0.004 0.000 0.420 0.007 0.000 0.000 1500.0 0.343 41.874 0.334 955.196 0.006 0.000 0.635 0.015 0.001 0.000 2000.0 0.341 41.304 0.442 954.922 0.008 0.000 0.840 0.027 0.002 0.000 2500.0 0.339 40.741 0.548 954.649 0.011 0.000 1.035 0.041 0.005 0.000 3000.0 0.337 40.186 0.653 954.376 0.014 0.000 1.220 0.057 0.008 0.000 3500.0 0.335 39.639 0.755 954.103 0.017 0.001 1.398 0.075 0.012 0.000 4000.0 0.333 39.097 0.856 953.830 0.020 0.001 1.567 0.095 0.017 0.000 4500.0 0.331 38.563 0.956 953.557 0.024 0.001 1.728 0.117 0.023 0.001 5000.0 0.329 38.035 1.054 953.284 0.027 0.001 1.882 0.139 0.030 0.001 5500.0 0.327 37.513 1.151 953.011 0.031 0.002 2.028 0.163 0.038 0.001 6000.0 0.325 36.996 1.246 952.739 0.035 0.002 2.168 0.188 0.047 0.002 6500.0 0.323 36.486 1.340 952.466 0.039 0.002 2.302 0.214 0.057 0.003 7000.0 0.321 35.981 1.433 952.194 0.043 0.003 2.429 0.241 0.068 0.003 7500.0 0.320 35.481 1.524 951.922 0.048 0.003 2.550 0.268 0.079 0.004 8000.0 0.318 34.986 1.615 951.650 0.052 0.004 2.665 0.296 0.092 0.005 8500.0 0.316 34.497 1.703 951.378 0.057 0.004 2.775 0.325 0.105 0.006 9000.0 0.314 34.012 1.791 951.107 0.061 0.005 2.879 0.354 0.118 0.007 9500.0 0.312 33.532 1.878 950.835 0.066 0.005 2.978 0.384 0.132 0.009 10000.0 0.310 33.057 1.963 950.564 0.071 0.006 3.072 0.414 0.147 0.010 10500.0 0.308 32.586 2.047 950.293 0.076 0.007 3.161 0.445 0.162 0.012 11000.0 0.307 32.120 2.130 950.023 0.081 0.007 3.246 0.476 0.178 0.014 11500.0 0.305 31.658 2.212 949.753 0.087 0.008 3.326 0.507 0.194 0.016 12000.0 0.303 31.200 2.293 949.483 0.092 0.009 3.402 0.539 0.210 0.018 12500.0 0.301 30.746 2.373 949.213 0.097 0.010 3.474 0.571 0.226 0.021 13000.0 0.300 30.296 2.452 948.944 0.103 0.011 3.541 0.603 0.243 0.024 13500.0 0.298 29.849 2.530 948.676 0.108 0.012 3.605 0.635 0.260 0.026 14000.0 0.296 29.407 2.607 948.407 0.114 0.013 3.665 0.668 0.277 0.029 14500.0 0.294 28.968 2.683 948.140 0.120 0.014 3.721 0.701 0.294 0.032 15000.0 0.293 28.532 2.758 947.873 0.125 0.015 3.774 0.733 0.311 0.036 15500.0 0.291 28.100 2.832 947.606 0.131 0.017 3.823 0.766 0.328 0.039 16000.0 0,289 27A671 2A905 947.339 0.137 0.018 3.869 0,799 0.346 0.043 16500.0 0.287 27.246 2.978 947.073 0.142 0.019 3.912 0.832 0.363 0.047 17000.0 0.286 26.824 3.049 946.806 0.148 0.020 3.953 0.865 0.380 0.051 17500.0 0.284 26.405 3.120 946.539 0.154 0.022 3.991 0.898 0.397 0.056 18000.0 0.282 25.990 3.190 946.272 0.160 0.023 4.027 0.930 0.415 0.060 18500.0 0.281 25.578 3.259 946.004 0.166 0.025 4.061 0.963 0.432 0.065 19000.0 0.279 25.169 3.327 945.734 0.172 0.026 4.093 0.996 0.449 0.070 19500.0 0.277 24.764 3.395 945.464 0.178 0.028 4.123 1.028 0.467 0.075 20000.0 0.276 24.362 3.461 945.193 0.184 0.030 4.151 1.061 0.484 0.080 22500.0 0.268 22.404 3.782 943.816 0.216 0.039 4.270 1.221 0.571 0.110 25000.0 0.259 20.532 4.083 942.404 0.250 0.051 4.354 1.376 0.656 0.145 27500.0 0.251 18.746 4.364 940.956 0.284 0.064 4.409 1.527 0.737 0.186 30000.0 0.243 17.045 4.624 939.468 0.319 0.079 4.438 1.673 0.814 0.233 32500.0 0.235 15.429 4.866 937.940 0.355 0.096 4.445 1.812 0.884 0.285 35000.0 0.227 13.900 5.087 936.368 0.391 0.115 4.434 1.944 0.949 0.343 37500.0 0.219 12.457 5.289 934.750 0.427 0.135 4.407 2.069 1.006 0.405 40000.0 0.211 11.102 5.471 933.083 0.463 0.157 4.368 2.185 1.057 0.473 42500.0 0.203 9.834 5.634 931.365 0.498 0.181 4.319 2.294 1.101 0.546 45000.0 0.195 8.656 5.777 929.594 0.533 0.206 4.263 2.393 1.138 0.624 47500.0 0.187 7.567 5.901 927.767 0.566 0.232 4.202 2.483 1.168 0.706 50000.0 0.179 6.568 6.005 925.882 0.598 0.258 4.137 2.563 1.193 0.792 52500.0 0.172 5.658 6.090 923.937 0.629 0.286 4.071 2.634 1.211 0.882 55000.0 0.164 4.838 6.157 921.932 0.658 0.313 4.006 2.696 1.225 0.974 57500.0 0.157 4.104 6.205 919.867 0.686 0.339 3.942 2.749 1.234 1.070 60000.0 0.150 3.455 6.235 917.741 0.711 0.366 3.880 2.794 1.239 1.168 62500.0 0.143 2.887 6.249 915.557 0.734 0.391 3.823 2.830 1.241 1.267 65000.0 0.136 2.394 6.248 913.317 0.755 0.415 3.770 2.859 1.240 1.368 67500.0 0.129 1.972 6.232 911.025 0.774 0.437 3.721 2.881 1.237 1.469 70000.0 0.123 1.615 6.204 908.685 0.790 0.458 3.677 2.897 1.233 1.569 AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1QXM Fuel Page C-34 Table C.33 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.636 0.000 956.015 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.517 0.024 955.951 0.000 0.000 0.022 0.000 0.000 0.000 500.0 0.347 43.044 0.119 955.694 0.002 0.000 0.227 0.002 0.000 0.000 1000.0 0.344 42.462 0.236 955.372 0.005 0.000 0.489 0.00: 0.000 0.000 1500.0 0.342 41.890 0.351 955.050 0.007 0.000 0.740 0.018 0.002 0.000 2000.0 0.340 41.327 0.463 954.729 0.010 0.000 0.978 0.031 0.004 0.000 2500.0 0.337 40.773 0.574 954.408 0.014 0.000 1.205 0.046 0.007 0.000 3000.0 0.335 40.228 0.682 954.087 0.017 0.001 1.422 0.064 0.011 0.000 3500.0 0.333 39.690 0.789 953.767 0.021 0.001 1.630 0.084 0.016 0.000 4000.0 0.330 39.160 0.894 953.446 0.025 0.001 1.828 0.106 0.023 0.001 4500.0 0.328 38.638 0.997 953.126 0.030 0.001 2.017 0.129 0.031 0.001 5000.0 0.326 38.122 1.098 952.806 0.034 0.002 2.198 0.154 0.040 0.001 5500.0 0.324 37.613 1.198 952.486 0.039 0.002 2.371 0.179 0.051 0.002 6000.0 0.321 37.110 1.296 952.167 0.044 0.003 2.536 0.206 0.062 0.002 6500.0 0.319 36.614 1.392 951.848 0.049 0.003 2.694 0.234 0.075 0.003 7000.0 0.317 36.124 1.487 951.529 0.054 0.004 2.845 0.262 0.088 0.004 7500.0 0.315 35.640 1.581 951.210 0.060 0.004 2.990 0.292 0.102 0.005 8000.0 0.313 35.161 1.673 950.891 0.065 0.005 3.128 0.322 0.117 0.006 8500.0 0.311 34.688 1.764 950.573 0.071 0.006 3.260 0.352 0.133 0.007 9000.0 0.308 34.220 1.853 950.255 0.077 0.007 3.386 0.384 0.150 0.009 9500.0 0.306 33.758 1.941 949.938 0.083 0.008 3.507 0.415 0.167 0.011 10000.0 0.304 33.300 2.028 949.620 0.089 0.009 3.622 0.448 0.185 0.012 10500.0 0.302 32.847 2.113 949.303 0.096 0.010 3.732 0.480 0.203 0.014 11000.0 0.300 32.400 2.197 948.987 0.102 0.011 3.837 0.513 0.222 0.017 11500.0 0.298 31.956 2.281 948.671 0.108 0.012 3.936 0.547 0.241 0.019 12000.0 0.296 31.518 2.362 948.355 0.115 0.013 4.032 0.581 0.260 0.022 12500.0 0.294 31.083 2.443 948.039 0.121 0.015 4.122 0.615 0.280 0.024 13000.0 0.292 30.654 2.522 947.724 0.128 0.016 4.208 0.649 0.300 0.027 13500.0 0.290 30.228 2.601 947.409 0.135 0.017 4.290 0.684 0.320 0.030 14000.0 0.288 29.806 2.678 947.095 0.142 0.019 4.367 0.719 0.340 0.034 14500.0 0.286 29.388 2.754 946.782 0.149 0.021 4.441 0.754 0.360 0.037 15000.0 0.284 28.975 2.829 946.469 0.156 0.022 4.510 0.789 0.381 0.041 15500.0 0.283 28.565 2.903 946.156 0.163 0.024 4.576 0.824 0.401 0.045 16000.0 0.281 28.158 2.976 945.844 0.170 0.026 4.639 0.860 0.421 0.049 16500.0 0.279 27.755 3.049 945.532 0.177 0.028 4.697 0.895 0.442 0.053 17000.0 0.277 27.356 3.120 945.220 0.184 0.030 4.753 0.931 0.462 0.057 17500.0 0.275 26.960 3.190 944.909 0.191 0.032 4.806 0.967 0.482 0.062 18000.0 0.273 26.568 3.259 944.597 0.198 0.034 4.856 1.002 0.503 0.067 18500.0 0.271 26.179 3.327 944.286 0.206 0.036 4.903 1.038 0.523 0.072 19000.0 0.270 25.794 3.395 943.974 0.213 0.038 4.948 1.073 0.543 0.077 19500.0 0.268 25.412 3.461 943.661 0.220 0.040 4.990 1.109 0.563 0.082 20000.0 0.266 25.033 3.527 943.347 0.228 0.043 5.031 1.144 0.583 0.088 20500.0 0.264 24.658 3.591 943.033 0.235 0.045 5.070 1.179 0.604 0.094 21000.0 0.262 24.287 3.655 942.718 0.242 0.048 5.106 1.214 0.624 0.100 21500.0 0.261 23.919 3.718 942.401 0.250 0.051 5.142 1.249 0.644 0.106 22500.0 0.257 23.193 3.842 941.765 0.265 0.056 5.207 1.319 0.684 0.119 25000.0 0.248 21.437 4.136 940.151 0.304 0.072 5.345 1.490 0.783 0.154 27500.0 0.240 19.767 4.409 938.504 0.343 0.089 5.451 1.655 0.879 0.195 30000.0 0.231 18.179 4.662 936.823 0.382 0.109 5.528 1.816 0.971 0.240 32500.0 0.223 16.673 4.895 935.108 0.422 0.132 5.580 1.971 1.058 0.290 35000.0 0.215 15.247 5.109 933.358 0.462 0.156 5.611 2.119 1.138 0.344 37500.0 0.207 13.901 5.303 931.570 0.502 0.183 5.623 2.260 1.213 0.402 40000.0 0.199 12.632 5.479 929.745 0.541 0.211 5.620 2.394 1.281 0.465 42500.0 0.191 11.442 5.635 927.882 0.580 0.242 5.603 2.520 1.343 0.531 45000.0 0.184 10.327 5.774 925.979 0.618 0.274 5.575 2.638 1.398 0.600 47500.0 0.177 9.288 5.895 924.037 0.654 0.307 5.538 2.747 1.448 0.673 50000.0 0.170 8.322 5.998 922.054 0.690 0.341 5.495 2.848 1.490 0.749 52500.0 0.163 7.429 6.085 920.032 0.723 0.377 5.446 2.941 1.528 0.828 55000.0 0.156 6.606 6.155 917.969 0.755 0.412 5.393 3.025 1.559 0.909 57500.0 0.150 5.851 6.210 915.865 0.786 0.448 5.338 3.101 1.585 0.992 60000.0 0.143 5.162 6.250 913.723 0.814 0.484 5.282 3.169 1.607 1.077 62500.0 0.137 4.537 6.276 911.542 0.840 0.519 5.226 3.229 1.624 1.164 65000.0 0.132 3.972 6.288 909.323 0.864 0.554 5.170 3.281 1.637 1.253 67500.0 0.126 3.465 6.288 907.069 0.886 0.587 5.116 3.327 1.647 1.342 70000.0 0.121 3.012 6.276 904.780 0.906 0.619 5.065 3.366 1.654 1.433 AREVA NP Inc.
Lontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM 1OXM Fuel M
T Page C-35 Table C.34 [ ] Exposure-Dependent 0% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.000 0.000 0.000 0.0 0.349 43.647 0.000 956.003 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.527 0.022 955.957 0.000 0.000 0.017 0.001 0.000 0.000 500.0 0.347 43.049 0.109 955.770 0.001 0.000 0. 167 0.006 0.000 0.000 1000.0 0.346 42.458 0.216 955.537 0.003 0.000 0.362 0.001 0.000 1500.0 0.344 41.875 0.322 955.303 0.005 0.000 0.546 0.013 0.023 0.002 0.000 2000.0 0.342 41.299 0.426 955.070 0.007 0.000 0.723 0.035 0.003 0.000 2500.0 0.340 40.730 0.529 954.837 0.009 0.000 0.890 0.050 0.006 0.000 3000.0 0.339 40.167 0.630 954.603 0.011 0.000 1.050 0.066 0.009 0.000 3500.0 0.337 39.610 0.730 954.370 0.014 0.000 1.202 0.084 0.012 0.000 4000.0 0.335 39.059 0.829 954.137 0.016 0.001 1.347 0.103 0.017 0.000 4500.0 0.333 38.514 0.926 953.904 0.019 0.001 1.485 0.124 0.022 0.001 5000.0 0.332 37.975 1.022 953.672 0.022 0.001 1.616 0.145 0.028 0.001 5500.0 0.330 37.440 1.117 953.440 0.025 0.001 1.741 6000.0 0.328 36.911 1.210 953.207 0.028 0.001 1.860 0.168 0.035 0.001 6500.0 0.327 36.387 1.302 952.976 0.031 0.002 1.973 0.191 0.043 0.002 7000.0 0.325 35.867 1.394 952.744 0.035 0.002 2.080 0.216 0.051 0.002 7500.0 0.323 35.352 1.484 952.513 0.038 0.002 2.182 0.241 0.060 0.003 8000.0 0.322 34.842 1.573 952.282 0.042 0.003 2.279 0.267 0.069 0.004 8500.0 0.320 34.336 1.661 952.052 0.045 0.003 2.371 0.293 0.079 0.005 9000.0 0.318 33.834 1.748 951.822 0.049 0.003 2.458 0.320 0.090 0.006 9500.0 0.317 33.337 1.834 951.592 0.053 0.004 2.540 0.348 0.101 0.007 10000.0 0.315 32.843 1.919 951.362 0.057 0.004 2.618 0.376 0.112 0.008 10500.0 0.313 32.353 2.003 951.134 0.061 0.005 2.691 0.404 0.124 0.009 11000.0 0.312 31.866 2.086 950.905 0.065 0.005 2.760 0.433 0.136 0.011 11500.0 0.310 31.384 2.168 950.677 0.069 0.006 2.826 0.462 0.148 0.013 12000.0 0.309 30.905 2.249 950.449 0.073 0.006 2.888 0.491 0.161 0.014 12500.0 0.307 30.429 2.330 950.221 0.077 0.007 2.946 0.520 0.174 0.016 13000.0 0.306 29.957 2.409 949.993 0.082 0.008 3.002 0.550 0.187 0.019 13500.0 0.304 29.489 2.488 949.764 0.086 0.008 3.054 0.580 0.201 0.021 14000.0 0.302 29.024 2.565 949.534 0.091 0.009 3.104 0.609 0.215 0.023 14500.0 0.301 28.562 2.642 949.304 0.095 0.010 3.151 0.639 0.229 0.026 15000.0 0.299 28.104 2.718 949.073 0.100 0.011 3.196 0.670 0.243 0.029 15500.0 0.298 27.650 2.794 948.841 0.105 0.012 3.238 0.700 0.257 0.032 17500.0 0.291 25.868 3.087 947.899 0.125 0.016 3.388 0.821 0.316 0.045 20000.0 0.283 23.721 3.436 946.693 0.151 0.022 3.533 0.973 0.393 0.067 22500.0 0.276 21.662 3.765 945.451 0.179 0.029 3.637 1.125 0.469 0.094 25000.0 0.268 19.690 4.074 944.170 0.209 0.038 3.707 1.273 0.543 0.127 27500.0 0.260 17.807 4.363 942.849 0.239 0.048 3.748 1.418 0.614 0.166 30000.0 0.251 16.014 4.633 941.483 0.271 0.060 3.763 1.559 0.680 0.211 32500.0 0.243 14.312 4.883 940.068 0.303 0.074 3.757 1.694 0.741 0.262 35000.0 0.235 12.702 5.112 938.602 0.336 0.089 3.734 1.822 0.796 0.320 37500.0 0.227 11.189 5.321 937.080 0.369 0.106 3.697 1.943 0.844 0.383 40000.0 0.219 9.775 5.509 935.496 0.402 0.124 3.650 2.056 0.886 0.453 42500.0 0.210 8.462 5.676 933.847 0.435 0.144 3.594 2.159 0.921 0.530 45000.0 0.202 7.254 5.820 932.128 0.467 0.165 3.533 2.253 0.950 0.612 47500.0 0.193 6.153 5.943 930.334 0.499 0.187 3.469 2.338 0.972 0.700 50000.0 0.185 5.161 6.043 928.463 0.529 0.209 3.405 2.412 0.989 0.793 52500.0 0.177 4.279 6.121 926.512 0.558 0.232 3.341 2.476 1.001 0.891 55000.0 0.168 3.506 6.178 924.480 0.584 0.254 3.281 2.530 1.008 0.993 57500.0 0.160 2.839 6.213 922.367 0.609 0.276 3.226 2.574 1.012 1.099 60000.0 0.152 2.273 6.229 920.176 0.632 0.296 3.175 2.609 1.013 1.208 62500.0 0.144 1.800 6.227 917.913 0.653 0.316 3.130 2.636 1.012 1.318 65000.0 0.136 1.412 6.209 915.582 0.671 0.334 3.091 2.656 1.009 1.429 67500.0 0.128 1.099 6.177 913.193 0.686 0.350 3.057 2.671 1.005 1.540 70000.0 0.121 0.849 6.133 910.753 0.699 0.364 3.028 2.680 1.001 1.650 AREVA NP Inc.
Lontrolned Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-36 Table C.35 [ ] Exposure-Dependent 40% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.647 0.000 956.003 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.528 0.023 955.950 0.000 0.000 0.019 0.000 0.000 0.000 500.0 0.347 43.051 0.113 955.737 0.002 0.000 0.190 0.001 0.000 0.000 1000.0 0.345 42.463 0.224 955.470 0.004 0.000 0.411 0.007 0.000 0.000 1500.0 0.343 41.884 0.333 955,203 0.006 0.000 0.620 0.015 0.001 0.000 2000.0 0.341 41.313 0.441 954,936 0.008 0.000 0.820 0.026 0.002 0.000 2500.0 0.339 40.749 0.546 954.670 0.011 0.000 1.010 0.040 0.005 0.000 3000.0 0.337 40.193 0.650 954.404 0.014 0.000 1.191 0.056 0.008 0.000 3500.0 0.335 39.644 0.753 954.138 0.016 0.001 1.363 0.074 0.011 0.000 4000.0 0.333 39.101 0.853 953,873 0.020 0.001 1.527 0.094
- 0.016 0.000 4500.0 0.331 38.564 0.953 953.608 0.023 0.001 1.683 0.115 0.022 0.001 5000.0 0.330 38.034 1.051 953.343 0.026 0.001 1.832 0.137 0.029 0.001 5500.0 0.328 37.510 1.147 953.079 0.030 0.001 1.974 0.161 0.037 0.001 6000.0 0.326 36.991 1.242 952.815 0.034 0.002 2.109 0.185 0.045 0.002 6500.0 0.324 36.478 1.336 952.551 0.038 0.002 2.237 0.211 0.055 0.002 7000.0 0.322 35.969 1.429 952.288 0.042 0.002 2.359 0.237 0.065 0.003 7500.0 0.320 35.466 1.520 952.025 0.046 0.003 2.475 0.264 0.076 0.004 8000.0 0.318 34.968 1.610 951,763 0.050 0.003 2.586 0.292 0.087 0.005 8500.0 0.317 34.475 1.699 951.501 0.054 0.004 2.691 0.320 0.100 0.006 9000.0 0.315 33.987 1.786 951.240 0.059 0.004 2.790 0.349 0.112 0.007 9500.0 0.313 33.503 1.873 950.979 0.063 0.005 2.885 0.378 0.126 0.008 10000.0 0.311 33.023 1.958 950.718 0.068 0.006 2.974 0.408 0.140 0.010 10500.0 0.309 32.547 2.042 950.459 0.073 0.006 3.059 0.438 0.154 0.011 11000.0 0.308 32.076 2.125 950.199 0.078 0.007 3.139 0.468 0.168 0.013 11500.0 0.306 31.608 2.207 949.940 0.083 0.008 3.215 0.499 0.183 0.015 12000.0 0.304 31.145 2.289 949.682 0.088 0.008 3.287 0.530 0.199 0.017 12500.0 0.303 30.685 2.369 949.423 0.093 0.009 3.356 0.561 0.214 0.020 13000.0 0.301 30.229 2.448 949.165 0.098 0.010 3.420 0.592 0.230 0.022 13500.0 0.299 29.776 2.526 948.906 0.104 0.011 3.482 0.624 0.246 0.025 14000.0 0.297 29.328 2.603 948.647 0.109 0.012 3.540 0.656 0.262 0.027 14500.0 0.296 28.883 2.680 948.387 0.114 0.013 3.596 0.687 0.279 0.030 15000.0 0.294 28.442 2.755 948.127 0.120 0.014 3.648 0.719 0.295 0.034 15500.0 0.292 28.004 2.830 947.865 0.125 0.015 3.699 0.751 0.312 0.037 16000.0 0.291 27.571 2.904 947.603 0.131 0.017 3.746 0.783 0.329 0.041 16500.0 0.289 27.141 2.976 947.340 0.137 0.018 3.792 0.815 0.346 0.044 17500.0 0.286 26.291 3.120 946.809 0.149 0.021 3.877 0.879 0.380 0.052 20000.0 0.277 24.233 3.463 945.461 0.179 0.028 4.055 1.039 0.468 0.076 22500.0 0.269 22.264 3.785 944.079 0.211 0.038 4.189 1.196 0.556 0.106 25000.0 0.260 20.384 4.087 942.662 0.245 0.049 4.287 1.351 0.642 0.141 27500.0 0.252 18.592 4.368 941.208 0.280 0.062 4.352 1.502 0.723 0.181 30000.0 0.244 16.887 4.629 939.714 0.316 0.077 4.389 1.648 0.800 0.227 32500.0 0.236 15.271 4.870 938.179 0.352 0.094 4.404 1.789 0.871 0.279 35000.0 0.228 13.741 5.091 936.600 0.388 0.113 4.398 1.922 0.936 0.336 37500.0 0.219 12.300 5.292 934.975 0.425 0.133 4.376 2.049 0.994 0.399 40000.0 0.211 10.948 5.473 933.300 0.461 0.155 4.341 2.167 1.045 0.467 42500.0 0.203 9.686 5.635 931.574 0.496 0.179 4.295 2.277 1.090 0.540 45000.0 0.195 8.513 5.777 929.793 0.531 0.204 4.241 2.377 1.127 0.618 47500.0 0.188 7.432 5.899 927.956 0.564 0.230 4.182 2.469 1.158 0.700 50000.0 0.180 6.441 6.001 926.061 0.597 0.257 4.119 2.551 1.183 0.786 52500.0 0.172 5.540 6.084 924.106 0.628 0.284 4.054 2.623 1.203 0.876 55000.0 0.164 4.730 6.149 922.089 0.657 0.311 3.990 2.687 1.217 0.969 57500.0 0.157 4.006 6.194 920.013 0.684 0.338 3.927 2.741 1.226 1.065 60000.0 0.150 3.367 6.223 917.876 0.710 0.364 3.868 2.786 1.232 1.163 62500.0 0.143 2.809 6.235 915.681 0.733 0.390 3.811 2.823 1.234 1.263 65000.0 0.136 2.327 6.231 913.430 0.754 0.413 3.759 2.852 1.234 1.364 67500.0 0.129 1.914 6.214 911.128 0.772 0.436 3.712 2.875 1.232 1.465 70000.0 0.123 1.565 6.184 908.778 0.789 0.456 3.669 2.892 1.228 1.566 AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page C-37 Table C.36 [ ] Exposure-Dependent 80% Void Isotopics (kg/MTU Initial)
Exposure MWd/MTU U-234 U-235 U-236 U-238 NP-237 PU-238 PU-239 PU-240 PU-241 PU-242 0.0 0.349 43.647 o.oob 956.003 0.000 0.000 0.000 0.000 0.000 0.000 100.0 0.349 43.528 0.024 955.941 0.000 0.000 0.022 0.000 0.000 0.000 500.0 0.347 43.055 0.119 955.690 0.002 0.000 0.221 0.002 0.000 0.000 1000.0 0.344 42.472 0.235 955.376 0.004 0.000 0.478 0.008 0.000 0.000 1500.0 0.342 41.900 0.349 955.062 0.007 0.000 0.721 0.017 0.001 0.000 2000.0 0.340 41.336 0.461 954.749 0.010 0.000 0.953 0.030 0.003 0.000 2500.0 0.338 40.781 0.571 954.436 0.013 0.000 1.174 0.046 0.006 0.000 3000.0 0.335 40.234 0.679 954.124 0.017 0.001 1.385 0.063 0.010 0.000 3500.0 0.333 39.695 0.785 953.812 0.021 0.001 1.586 0.083 0.016 0.000 4000.0 0.331 39.164 0.889 953.501 0.025 0.001 1.777 0.105 0.022 0.001 4500.0 0.329 38.639 0.992 953.190 0.029 0.001 1.960 0.127 0.030 0.001 5000.0 0.326 38.121 1.093 952.880 0.033 0.002 2.135 0.152 0.039 0.001 5500.0 0.324 37.610 1.192 952.570 0.038 0.002 2.301 0.177 0.049 0.002 6000.0 0.322 37.105 1.290 952.260 0.042 0.003 2.461 0.204 0.060 0.002 6500.0 0.320 36.606 1.386 951.951 0.047 0.003 2.612 0.231 0.072 0.003 7000.0 0.318 36.114 1.481 951.642 0.052 0.004 2.757 0.259 0.084 0.004 7500.0 0.316 35.626 1.574 951.334 0.058 0.004 2.896 0.288 0.098 0.005 8000.0 0.314 35.144 1.666 951.026 0.063 0.005 3.028 0.318 0.113 0.006 8500.0 0.311 34.668 1.756 950.720 0.069 0.006 3.154 0.348 0.128 0.007 9000.0 0.309 34.196 1.846 950.413 0.074 0.006 3.274 0.379 0.144 0.009 9500.0 0.307 33.729 1.933 950.107 0.080 0.007 3.389 0.410 0.160 0.010 10000.0 0.305 33.268 2.020 949.801 0.086 0.008 3.498 0.442 0.177 0.012 10500.0 0.303 32.811 2.105 949.496 0.092 0.009 3.602 0.474 0.194 0.014 11000.0 0.301 32.358 2.190 949.192 0.098 0.010 3.701 0.507 0.212 0.016 11500.0 0.299 31.910 2.273 948.888 0.104 0.011 3.796 0.540 0.230 0.018 12000.0 0.297 31.465 2.354 948.585 0.110 0.012 3.885 0.573 0.248 0.020 12500.0 0.296 31.026 2.435 948.282 0.117 0.014 3.971 0.607 0.266 0.023 13000.0 0.294 30.590 2.515 947.979 0.123 0.015 4.053 0.641 0.285 0.026 13500.0 0.292 30.158 2.593 947.676 0.130 0.016 4.131 0.674 0.304 0.029 14000.0 0.290 29.731 2.671 947.373 0.136 0.018 4.205 0.709 0.323 0.032 14500.0 0.288 29.307 2.747 947.069 0.143 0.019 4.276 0.743 0.343 0.035 15000.0 0.286 28.887 2.823 946.766 0.149 0.021 4.344 0.777 0.362 0.039 15500.0 0.284 28.471 2.897 946.461 0.156 0.022 4.409 0.811 0.382 0.042 16000.0 0.282 28.059 2.971 946.156 0.163 0.024 4.471 0.846 0.402 0.046 16500.0 0.280 27.650 3.043 945.850 0.170 0.026 4.531 0.880 0.422 0.050 17000.0 0.279 27.246 3.115 945.544 0.177 0.028 4.588 0.915 0.442 0.055 17500.0 0.277 26.845 3.185 945.236 0.184 0.030 4.643 0.950 0.462 0.059 18000.0 0.275 26.448 3.255 944.927 0.191 0.032 4.696 0.984 0.482 0.064 18500.0 0.273 26.055 3.324 944.617 0.199 0.034 4.746 1.019 0.502 0.069 19000.0 0.271 25.666 3.392 944.306 0.206 0.036 4.794 1.053 0.522 0.074 20000.0 0.268 24.898 3.525 943.680 0.221 0.041 4.885 1.123 0.563 0.084 22500.0 0.259 23.042 3.842 942.093 0.259 0.054 5.081 1.294 0.665 0.114 25000.0 0.250 21.277 4.137 940.473 0.298 0.069 5.236 1.462 0.765 0.150 27500.0 0.241 19.598 4.411 938.820 0.337 0.087 5.356 1.627 0.861 0.190 30000.0 0.233 18.005 4.665 937.133 0.377 0.107 5.445 1.787 0.953 0.235 32500.0 0.224 16.496 4.898 935.411 0.418 0.129 5.507 1.942 1.040 0.284 35000.0 0.216 15.068 5.111 933.653 0.458 0.153 5.546 2.091 1.121 0.338 37500.0 0.208 13.722 5.305 931.858 0.498 0.180 5.565 2.233 1.196 0.397 40000.0 0.200 12.456 5.479 930.025 0.538 0.208 5.567 2.368 1.265 0.459 42500.0 0.192 11.268 5.635 928.153 0.577 0.239 5.555 2.496 1.327 0.525 45000.0 0.185 10.158 5.772 926.242 0.615 0.271 5.532 2.615 1.383 0.594 47500.0 0.177 9.124 5.891 924.290 0.652 0.304 5.498 2.726 1.432 0.667 50000.0 0.170 8.165 5.993 922.298 0.687 0.339 5.458 2.829 1.476 0.743 52500.0 0.163 7.279 6.077 920.265 0.721 0.374 5.411 2.923 1.513 0.822 55000.0 0.156 6.463 6.146 918.192 0.753 0.410 5.361 3.009 1.545 0.903 57500.0 0.150 5.717 6.199 916.079 0.784 0.446 5.308 3.086 1.572 0.987 60000.0 0.144 5.037 6.237 913.926 0.812 0.481 5.254 3.155 1.594 1.072 62500.0 0.138 4.421 6.260 911.734 0.838 0.517 5.200 3.216 1.612 1.159 65000.0 0.132 3.865 6.271 909.505 0.862 0.551 5.146 3.269 1.626 1.248 67500.0 0.126 3.368 6.269 907.240 0.884 0.584 5.094 3.315 1.636 1.338 70000.0 0.121 2.924 6.255 904.941 0.904 0.616 5.044 3.355 1.644 1.428 AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-1 Appendix D Lattice Enrichment Distribution Maps AREVA NP Inc.
uontronled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page D-2 I
I Figure D.1 [ ] Enrichment Distribution AREVA NP Inc.
Lontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM 1OXM Fuel M
T Page D-3
[
I Figure D.2 [ ] Enrichment Distribution AREVA NP Inc.
uontroiied uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page D-4 I
I Figure D.3 [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UM TM 1OXM Fuel Page D-5 I
I Figure D.4 [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-6
[
Figure D.5 [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-7 I
I Figure D.6 [ ] Enrichment Distribution AREVA NP Inc.
(Jontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-8
[
I Figure D.7 [ ] Enrichment Distribution AREVA NP Inc.
uontrolied Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Pacge D-9 I
I Figure D.8 [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UM TM 1OXM Fuel Page D-10
[
I Figure D.9 [ ] Enrichment Distribution AREVA NP Inc.
L;ontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-11
[
I Figure D.1O [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-12 I
I Figure D.11 [ ] Enrichment Distribution AREVA NP Inc.
Luontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-13 I
I Figure D.12 [ ] Enrichment Distribution AREVA NP Inc.
u;ontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-14 I
I Figure D.13 [ ] Enrichment Distribution AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM IOXM Fuel Page D-15 I
I Figure D.14 [ ] Enrichment Distribution AREVA NP Inc.
Lontrollec uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-16
[
I Figure D.15 [ ] Enrichment Distribution AREVA NP Inc.
uontrollecd uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UM TM 1OXM Fuel Page D-17
[
I Figure D.16 [ ] Enrichment Distribution AREVA NP Inc.
Uontrollea uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-18
[
I Figure D.17 [ ] Enrichment Distribution AREVA NP Inc.
uontronled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-19
[
I Figure D.18 [ ] Enrichment Distribution AREVA NP Inc.
uontrolled uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-20
[
I Figure D.19 [ ] Enrichment Distribution AREVA NP Inc.
uJontrollea uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-21 I
Figure D.20 [ ] Enrichment Distribution AREVA NP Inc.
Uontroiled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-22 I
I Figure D.21 [ ] Enrichment Distribution AREVA NP Inc.
uontrolled Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRI UM TM 1OXMV Fuel Page D-23
[
I Figure D.22 [ ] Enrichment Distribution AREVA NP Inc.
Uontrolled uocument ANP-3139(NP)
Nuclear Fuel Design Report Monticello Cycle 28 Revision 1 ATRIUMTM 1OXM Fuel Page D-24 I
I Figure D.23 [ ] Enrichment Distribution AREVA NP Inc.
Uontrollea Uocument Nuclear Fuel Design Report ANP-3139(NP)
Monticello Cycle 28 Revision 1 ATRIUM TM 1OXM Fuel Page D-25
[
I Figure D.24 [ ] Enrichment Distribution AREVA NP Inc.