ML092990026

From kanterella
Jump to navigation Jump to search

RAI Re. Associated Circuit Analysis for the Proposed Extended Power Uprate Amendment
ML092990026
Person / Time
Site: Monticello 
Issue date: 10/25/2009
From: Tam P
Plant Licensing Branch III
To: Gunderson L, Salamon G
Northern States Power Co, Xcel Energy
Tam P
References
TAC MD9990
Download: ML092990026 (2)


Text

Accession No. ML092990026 From:

Tam, Peter Sent:

Sunday, October 25, 2009 5:44 PM To:

'Gunderson, Lynne'; Salamon, Gabor Cc:

Dennig, Robert; Lobel, Richard

Subject:

Monticello EPU amendment - Draft technical position on NSPM's 7/13/09 response (TAC MD9990)

Lynne:

By letter dated July 13, 2009, NSPM responded to Question 38, among other things, of the NRC staff's RAIs regarding the containment system. NSPM stated that the associated circuits analyses conducted previous to 2004 did not include a loss of containment overpressure. The response stated that this finding was entered into the Monticello corrective action program for evaluation at CLTP and EPU conditions. The NRC staff does not find this approach acceptable. Since use of containment accident pressure is predicated upon containment integrity, this issue needs to be resolved as a regulatory issue prior to approval of the EPU amendment.

Please let me know if you want to discuss in a phone call this NRC staff position. Also, let me know if you want this position be formally conveyed to you by letter.

Peter S. Tam Senior Project Manager (for Kewaunee and Monticello)

Plant Licensing Branch III-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Tel. 301-415-1451 E-mail Properties Mail Envelope Properties (0A64B42AAA8FD4418CE1EB5240A6FED102BDCE21EB)

Subject:

Monticello EPU amendment - Draft technical position on NSPM's 7/13/09 response (TAC MD9990)

Sent Date: 10/25/2009 5:44:29 PM Received Date: 10/25/2009 5:44:00 PM From: Tam, Peter Created By: Peter.Tam@nrc.gov Recipients:

Lynne.Gunderson@xenuclear.com ('Gunderson, Lynne')

Tracking Status: None

Gabor.Salamon@xenuclear.com (Salamon, Gabor)

Tracking Status: None Robert.Dennig@nrc.gov (Dennig, Robert)

Tracking Status: None Richard.Lobel@nrc.gov (Lobel, Richard)

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 9837 10/25/2009 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: