{{#Wiki_filter:Feb. 20, 2014Page1 of 2MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2014-6725 USER INFORMATION:
{{#Wiki_filter:Feb. 20, 2014 Page 1 of 2 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2014-6725 USER INFORMATION:
GERLACH*ROSEY MEMPL#:028401 CA#: 0363Address:
GERLACH*ROSEY M EMPL#:028401 CA#: 0363 Address: NUCSA2 Phone#: 254-3194 TRANSMITTAL INFORMATION:
NUCSA2Phone#: 254-3194TRANSMITTAL INFORMATION:
TO: GERLACH*ROSEY M LOCATION:
TO: GERLACH*ROSEY MLOCATION:
USNRC 02/20/2014 FROM: NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU. HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.
USNRC02/20/2014 FROM: NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE.UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL. TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.TSB1 -TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 12/10/2013 ADD MANUAL TABLE OF CONTENTS DATE: 02/19/2014 CATEGORY:
THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNEDTO YOU. HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ONTHIS TRANSMITTAL.
DOCUMENTS TYPE: TSBI Feb. 20, 2014 Page 2 of 2 ID: TEXT 3.4.6 REMOVE: REV:3 ADD: REV: 4 CATEGORY:
WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE.UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL. TOOLSFROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OFERRORS.ATTENTION:  
DOCUMENTS TYPE: TSB1 ID: TEXT LOES ADD: REV: 113 REMOVE: REV:112 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.
"REPLACE" directions do not affect the Table of Contents, Therefore noTOC will be issued with the updated material.
UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.
TSB1 -TECHNICAL SPECIFICATION BASES UNIT 1 MANUALREMOVE MANUAL TABLE OF CONTENTS DATE: 12/10/2013 ADD MANUAL TABLE OF CONTENTS DATE: 02/19/2014 CATEGORY:
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.
DOCUMENTS TYPE: TSBI Feb. 20, 2014Page 2 of 2ID: TEXT 3.4.6REMOVE: REV:3ADD: REV: 4CATEGORY:
SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents'Issue Date: 02/19/2014 Procedure Name Rev TEXT LOES 113 Title: LIST OF EFFECTIVE SECTIONS CO N T OLLPD Issue Date 02/19/2014 Change ID Change Number TEXT TOC Title: TABLE OF CONTENTS 22 03/28/2013 TEXT 2.1.1 5 Title: SAFETY LIMITS (SLS) REACTOR TEXT 2.1.2 1 Title: SAFETY LIMITS (SLS) REACTOR 05/06/2009 CORE SLS 10/04/2007 COOLANT SYSTEM (RCS) PRESSURE S TEXT 3.0 3 08/20/2009 Title: LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY TEXT 3.1.1 Title: REACTIVITY TEXT 3.1.2 Title: REACTIVITY TEXT 3.1.3 Title: REACTIVITY TEXT 3.1.4 Title: REACTIVITY TEXT 3.1.5 Title: REACTIVITY TEXT 3.1.6 Title: REACTIVITY 1 04/18/2006 CONTROL SYSTEMS SHUTDOWN MARGIN (SDM)0 11/15/2002 CONTROL SYSTEMS REACTIVITY ANOMALIES 2 CONTROL SYSTEMS 4 CONTROL SYSTEMS 1 CONTROL SYSTEMS 2 CONTROL SYSTEMS 01/19/2009 CONTROL ROD OPERABILITY 01/30/2009 CONTROL ROD SCRAM TIMES 07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 04/18/2006 ROD PATTERN CONTROL Page 1 of 8 Report Date: 02/20/14 Page I of 8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 4 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.1.7 3 04/23/2008 Title: REACTIVITY CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC) SYSTEM TEXT 3.1.8 3 05/06/2009 Title: REACTIVITY CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV) VENT AND DRAIN VALVES TEXT 3.2.1 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)TEXT 3.2.2 3 05/06/2009 Title: POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)TEXT 3.2.3 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)TEXT 3.3.1.1 5 07/23/2013 Title: INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT 3.3.1.2 2 01/19/2009 Title: INSTRUMENTATION SOURCE RANGE MONITOR (SRM) INSTRUMENTATION TEXT 3.3.2.1 3 04/23/2008 Title: INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 2 04/05/2010 Title: INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 9 02/28/2013 Title: INSTRUMENTATION POST ACCIDENT MONITORING (PAM) INSTRUMENTATION TEXT 3.3.3.2 1 04/18/2005 Title: INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 Title: INSTRUMENTATION 1 04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)
DOCUMENTS TYPE: TSB1ID: TEXT LOESADD: REV: 113REMOVE: REV:112ANY DISCREPANCIES WITH THE MATERIAL  
INSTRUMENTATIO W Pager of 8 Report Date: 02/20/14 Page 2 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.4.2 0 11/15/2002 Title: INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)
: PROVIDED, CONTACT DCS @ X3107 OR X3136 FORASSISTANCE.
INSTRUMENTATION TEXT 3.3.5.1 Title: INSTRUMENTATION TEXT 3.3.5.2 Title: INSTRUMENTATION 3 08/20/2009 EMERGENCY CORE COOLING SYSTEM (ECCS) INSTRUMENTATION 0 11/15/2002 REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION TEXT 3.3.6.1 5 07/23/2013 Title: INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 Title: INSTRUMENTATION TEXT 3.3.7.1 Title: INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1 Title: INSTRUMENTATION TEXT 3.3.8.2 Title: INSTRUMENTATION TEXT 3.4.1 Title: REACTOR COOLANT 4 09/01/2010 SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 2 10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM 2 12/17/2007 LOSS OF POWER (LOP) INSTRUMENTATION 0 11/15/2002 REACTOR PROTECTION SYSTEM (RPS) ELECTRIC POWER MONITORING 4 04/27/2010 SYSTEM (RCS) RECIRCULATION LOOPS OPERATING TEXT 3.4.2 3 10/23/2013 Title: REACTOR COOLANT SYSTEM (RCS) JET PUMPS TEXT 3. 4.3 Title: REACTOR COOLANT TEXT 3.4.4 Title: REACTOR COOLANT 3 01/13/2012 SYSTEM RCS SAFETY RELIEF VALVES S/RVS 0 11/15/2002 SYSTEM (RCS) RCS OPERATIONAL LEAKAGE Page3 of 8 Report Date: 02/20/14 Page 3 of 8 Report Date: 02/20/14 SSES M4A.NUAL Manual Name: TSBI Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.4.5 1 01/16/2006 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 4 02/19/2014 Title: REACTOR COOLANT SYSTEM (RCS) RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2 10/04/2007 Title: REACTOR COOLANT SYSTEM (RCS) RCS SPECIFIC ACTIVITY TEXT 3.4.8 Title: REACTOR COOLANT-HOT SHUTDOWN TEXT 3.4.9 Title: REACTOR COOLANT-COLD SHUTDOWN 2 SYSTEM (RCS)1 SYSTEM (RCS)03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING SYSTEM 03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING SYSTEM 0 TEXT 3.4.10 3 04/23/2008 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.11 0 11/15/2002 Title: REACTOR COOLANT SYSTEM (RCS) REACTOR STEAM DOME PRESSURE TEXT 3.5.1 2 01/16/2006 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM ECCS -OPERATING TEXT 3.5.2 0 11/15/2002 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM ECCS -SHUTDOWN TEXT 3.5.3 2 07/09/2010 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM RCIC SYSTEM CORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)TEXT 3.6.1.1 Title: PRIMARY CONTAINMENT 4 11/09/2011 TEXT 3.6.1.2 1 04/23/2008 Title: CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK Page4 of 8 Report Date: 02/20/14 Page 4 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSBl Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.1.3 Title: CONTAINMENT TEXT 3.6.1.4 Title: CONTAINMENT TEXT 3.6.1.5 Title: CONTAINMENT TEXT 3.6.1.6 Title: CONTAINMENT TEXT 3.6.2.1 Title: CONTAINMENT TEXT 3.6.2.2 Title: CONTAINMENT TEXT 3.6.2.3 Title: CONTAINMENT TEXT 3.6.2.4 Title: CONTAINMENT TEXT 3.6.3.1 Title: CONTAINMENT TEXT 3.6.3.2 Title: CONTAINMENT TEXT 3.6.3.3 Title: CONTAINMENT TEXT 3.6.4.1 Title: CONTAINMENT 10 05/23/2012 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)1 04/23/2008 SYSTEMS CONTAINMENT PRESSURE 1 10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 2 04/23/2008 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 1 01/16/2006 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL COOLING 0 11/15/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL SPRAY 2 06/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1 04/18/2005 SYSTEMS DRYWELL AIR FLOW SYSTEM 1 02/28/2013 SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION 9 12/10/2013 SYSTEMS SECONDARY CONTAINMENT Page 5 of 8 Report Date: 02/20/14 Page 5 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.4.2 8 03/28/2013 Title: CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)TEXT 3.6.4.3 4 09/21/2006 Title: CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT) SYSTEM TEXT 3.7.1 4 04/05/2010 Title: PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW) SYSTEM AND THE ULTIMATE HEAT SINK (UHS)TEXT 3.7.2 Title: PLANT 2 02/11/2009 SYSTEMS EMERGENCY SERVICE WATER (ESW) SYSTEM TEXT 3.7.3 Title: PLANT SYSTEMS 1 01/08/2010 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM TEXT 3.7.4 Title: PLANT TEXT 3.7.5 Title: PLANT TEXT 3.7.6 Title: PLANT TEXT 3.7.7 Title: PLANT 0 11/15/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1 10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS 2 04/23/2008 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1 10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL TEXT 3.7.8 Title: PLANT SYSTEMS 0 04/23/2008 TEXT 3.8.1 6 05/06/2009 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -OPERATING TEXT 3.8.2 0 11/15/2002 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -SHUTDOWN Page~ of 8 Report Date: 02/20/14 Page 6 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.3 Title: ELECTRICAL TEXT 3.8.4 Title: ELECTRICAL TEXT 3.8.5 Title: ELECTRICAL TEXT 3.8.6 Title: ELECTRICAL TEXT 3.8.7 Title: ELECTRICAL TEXT 3.8.8 Title: ELECTRICAL TEXT 3.9.1 Title: REFUELING TEXT 3.9.2 Title: REFUELING TEXT 3.9.3 Title: REFUELING C TEXT 3.9.4 Title: REFUELING C TEXT 3.9.5 Title: REFUELING C TEXT 3.9.6 Title: REFUELING C 4 10/23/2013 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3 01/19/2009 POWER SYSTEMS DC SOURCES -OPERATING 1 12/14/2006 POWER SYSTEMS DC SOURCES -SHUTDOWN POWER SYST POWER SYST POWER SYST)PERATIONS)PERATIONS)PERATIONS)PERATIONS)PERATIONS)PERATIONS 1 12/14/2006
UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS INACCORDANCE WITH DEPARTMENT PROCEDURES.
PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.
FOR ELECTRONIC MANUALUSERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE INYOUR NIMS INBOX.
SSES MANUALManual Name: TSB1Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTable Of Contents'Issue Date: 02/19/2014 Procedure Name RevTEXT LOES 113Title: LIST OF EFFECTIVE SECTIONSCO N T OLLPDIssue Date02/19/2014 Change ID Change NumberTEXT TOCTitle: TABLE OF CONTENTS22 03/28/2013 TEXT 2.1.1 5Title: SAFETY LIMITS (SLS) REACTORTEXT 2.1.2 1Title: SAFETY LIMITS (SLS) REACTOR05/06/2009 CORE SLS10/04/2007 COOLANT SYSTEM (RCS) PRESSURE STEXT 3.0 3 08/20/2009 Title: LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY TEXT 3.1.1Title: REACTIVITY TEXT 3.1.2Title: REACTIVITY TEXT 3.1.3Title: REACTIVITY TEXT 3.1.4Title: REACTIVITY TEXT 3.1.5Title: REACTIVITY TEXT 3.1.6Title: REACTIVITY 1 04/18/2006 CONTROL SYSTEMS SHUTDOWN MARGIN (SDM)0 11/15/2002 CONTROL SYSTEMS REACTIVITY ANOMALIES 2CONTROL SYSTEMS4CONTROL SYSTEMS1CONTROL SYSTEMS2CONTROL SYSTEMS01/19/2009 CONTROL ROD OPERABILITY 01/30/2009 CONTROL ROD SCRAM TIMES07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 04/18/2006 ROD PATTERN CONTROLPage 1 of 8 Report Date: 02/20/14Page Iof 8Report Date: 02/20/14 SSES MANUALManual Name: TSB14Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.1.7 3 04/23/2008 Title: REACTIVITY CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC) SYSTEMTEXT 3.1.8 3 05/06/2009 Title: REACTIVITY CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV) VENT AND DRAIN VALVESTEXT 3.2.1 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)TEXT 3.2.2 3 05/06/2009 Title: POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)TEXT 3.2.3 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)TEXT 3.3.1.1 5 07/23/2013 Title: INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT 3.3.1.2 2 01/19/2009 Title: INSTRUMENTATION SOURCE RANGE MONITOR (SRM) INSTRUMENTATION TEXT 3.3.2.1 3 04/23/2008 Title: INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 2 04/05/2010 Title: INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 9 02/28/2013 Title: INSTRUMENTATION POST ACCIDENT MONITORING (PAM) INSTRUMENTATION TEXT 3.3.3.2 1 04/18/2005 Title: INSTRUMENTATION REMOTE SHUTDOWN SYSTEMTEXT 3.3.4.1Title: INSTRUMENTATION 1 04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)
INSTRUMENTATIO WPager of 8 Report Date: 02/20/14Page 2 of .8Report Date: 02/20/14 SSES MANUALManual Name: TSB1Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.3.4.2 0 11/15/2002 Title: INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP(ATWS-RPT)
INSTRUMENTATION TEXT 3.3.5.1Title: INSTRUMENTATION TEXT 3.3.5.2Title: INSTRUMENTATION 3 08/20/2009 EMERGENCY CORE COOLING SYSTEM (ECCS) INSTRUMENTATION 0 11/15/2002 REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION TEXT 3.3.6.1 5 07/23/2013 Title: INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2Title: INSTRUMENTATION TEXT 3.3.7.1Title: INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1Title: INSTRUMENTATION TEXT 3.3.8.2Title: INSTRUMENTATION TEXT 3.4.1Title: REACTOR COOLANT4 09/01/2010 SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 2 10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEM2 12/17/2007 LOSS OF POWER (LOP) INSTRUMENTATION 0 11/15/2002 REACTOR PROTECTION SYSTEM (RPS) ELECTRIC POWER MONITORING 4 04/27/2010 SYSTEM (RCS) RECIRCULATION LOOPS OPERATING TEXT 3.4.2 3 10/23/2013 Title: REACTOR COOLANT SYSTEM (RCS) JET PUMPSTEXT 3. 4.3Title: REACTOR COOLANTTEXT 3.4.4Title: REACTOR COOLANT3 01/13/2012 SYSTEM RCS SAFETY RELIEF VALVES S/RVS0 11/15/2002 SYSTEM (RCS) RCS OPERATIONAL LEAKAGEPage3 of 8 Report Date: 02/20/14Page 3 of 8Report Date: 02/20/14 SSES M4A.NUALManual Name: TSBIManual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.4.5 1 01/16/2006 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGETEXT 3.4.6 4 02/19/2014 Title: REACTOR COOLANT SYSTEM (RCS) RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2 10/04/2007 Title: REACTOR COOLANT SYSTEM (RCS) RCS SPECIFIC ACTIVITYTEXT 3.4.8Title: REACTOR COOLANT-HOT SHUTDOWNTEXT 3.4.9Title: REACTOR COOLANT-COLD SHUTDOWN2SYSTEM (RCS)1SYSTEM (RCS)03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING SYSTEM03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLINGSYSTEM0TEXT 3.4.10 3 04/23/2008 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE AND TEMPERATURE (P/T) LIMITSTEXT 3.4.11 0 11/15/2002 Title: REACTOR COOLANT SYSTEM (RCS) REACTOR STEAM DOME PRESSURETEXT 3.5.12 01/16/2006 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTORSYSTEM ECCS -OPERATING TEXT 3.5.2 0 11/15/2002 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTORSYSTEM ECCS -SHUTDOWNTEXT 3.5.3 2 07/09/2010 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTORSYSTEM RCIC SYSTEMCORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)TEXT 3.6.1.1Title: PRIMARY CONTAINMENT 4 11/09/2011 TEXT 3.6.1.2 1 04/23/2008 Title: CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCKPage4 of 8 Report Date: 02/20/14Page 4 of .8Report Date: 02/20/14 SSES MANUALManual Name: TSBlManual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.6.1.3Title: CONTAINMENT TEXT 3.6.1.4Title: CONTAINMENT TEXT 3.6.1.5Title: CONTAINMENT TEXT 3.6.1.6Title: CONTAINMENT TEXT 3.6.2.1Title: CONTAINMENT TEXT 3.6.2.2Title: CONTAINMENT TEXT 3.6.2.3Title: CONTAINMENT TEXT 3.6.2.4Title: CONTAINMENT TEXT 3.6.3.1Title: CONTAINMENT TEXT 3.6.3.2Title: CONTAINMENT TEXT 3.6.3.3Title: CONTAINMENT TEXT 3.6.4.1Title: CONTAINMENT 10 05/23/2012 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)1 04/23/2008 SYSTEMS CONTAINMENT PRESSURE1 10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS2 04/23/2008 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL1 01/16/2006 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL COOLING0 11/15/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL SPRAY2 06/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1 04/18/2005 SYSTEMS DRYWELL AIR FLOW SYSTEM1 02/28/2013 SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION 9 12/10/2013 SYSTEMS SECONDARY CONTAINMENT Page 5 of 8 Report Date: 02/20/14Page 5 of .8Report Date: 02/20/14 SSES MANUALManual Name: TSB1Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.6.4.2 8 03/28/2013 Title: CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)TEXT 3.6.4.3 4 09/21/2006 Title: CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT) SYSTEMTEXT 3.7.1 4 04/05/2010 Title: PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW) SYSTEM AND THEULTIMATE HEAT SINK (UHS)TEXT 3.7.2Title: PLANT2 02/11/2009 SYSTEMS EMERGENCY SERVICE WATER (ESW) SYSTEMTEXT 3.7.3Title: PLANT SYSTEMS1 01/08/2010 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS)
SYSTEMTEXT 3.7.4Title: PLANTTEXT 3.7.5Title: PLANTTEXT 3.7.6Title: PLANTTEXT 3.7.7Title: PLANT0 11/15/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM1 10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS2 04/23/2008 SYSTEMS MAIN TURBINE BYPASS SYSTEM1 10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVELTEXT 3.7.8Title: PLANT SYSTEMS0 04/23/2008 TEXT 3.8.16 05/06/2009 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -OPERATING TEXT 3.8.2 0 11/15/2002 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -SHUTDOWNPage~ of 8 Report Date: 02/20/14Page 6 of .8Report Date: 02/20/14 SSES MANUALManual Name: TSB1Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.8.3Title: ELECTRICAL TEXT 3.8.4Title: ELECTRICAL TEXT 3.8.5Title: ELECTRICAL TEXT 3.8.6Title: ELECTRICAL TEXT 3.8.7Title: ELECTRICAL TEXT 3.8.8Title: ELECTRICAL TEXT 3.9.1Title: REFUELING TEXT 3.9.2Title: REFUELING TEXT 3.9.3Title: REFUELING CTEXT 3.9.4Title: REFUELING CTEXT 3.9.5Title: REFUELING CTEXT 3.9.6Title: REFUELING C4 10/23/2013 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR3 01/19/2009 POWER SYSTEMS DC SOURCES -OPERATING 1 12/14/2006 POWER SYSTEMS DC SOURCES -SHUTDOWNPOWER SYSTPOWER SYSTPOWER SYST)PERATIONS
)PERATIONS
)PERATIONS
)PERATIONS
)PERATIONS
)PERATIONS 1 12/14/2006
'EMS BATTERY CELL PARAMETERS 1 10/05/2005
'EMS BATTERY CELL PARAMETERS 1 10/05/2005
'EMS DISTRIBUTION SYSTEMS -OPERATING 0 11/15/2002 PEMS DISTRIBUTION SYSTEMS -SHUTDOWN0 11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1 09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0 11/15/2002 CONTROL ROD POSITION0 11/15/2002 CONTROL ROD POSITION INDICATION 0 11/15/2002 CONTROL ROD OPERABILITY  
'EMS DISTRIBUTION SYSTEMS -OPERATING 0 11/15/2002 PEMS DISTRIBUTION SYSTEMS -SHUTDOWN 0 11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1 09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0 11/15/2002 CONTROL ROD POSITION 0 11/15/2002 CONTROL ROD POSITION INDICATION 0 11/15/2002 CONTROL ROD OPERABILITY  
-REFUELING 1 10/04/2007 REACTOR PRESSURE VESSEL (RPV) WATER LEVELPage7 of 8 Report Date: 02/20/14Page 7 of 8Report Date: 02/20/14 SSES MANUALManual Name: TSB1Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUALTEXT 3.9.7 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -HIGH WATER LEVELTEXT 3.9.8 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -LOW WATER LEVELTEXT 3.10.1Title: SPECIALTEXT 3.10.2Title: SPECIALTEXT 3.10.3Title: SPECIALTEXT 3.10.4Title: SPECIALTEXT 3.10.5Title: SPECIALTEXT 3.10.6Title: SPECIALTEXT 3.10.7Title: SPECIALTEXT 3.10.8Title: SPECIALOPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1 01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0 11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL  
-REFUELING 1 10/04/2007 REACTOR PRESSURE VESSEL (RPV) WATER LEVEL Page7 of 8 Report Date: 02/20/14 Page 7 of 8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.9.7 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -HIGH WATER LEVEL TEXT 3.9.8 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -LOW WATER LEVEL TEXT 3.10.1 Title: SPECIAL TEXT 3.10.2 Title: SPECIAL TEXT 3.10.3 Title: SPECIAL TEXT 3.10.4 Title: SPECIAL TEXT 3.10.5 Title: SPECIAL TEXT 3.10.6 Title: SPECIAL TEXT 3.10.7 Title: SPECIAL TEXT 3.10.8 Title: SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1 01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0 11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL  
-HOT SHUTDOWN0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL  
-HOT SHUTDOWN 0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL  
-COLD SHUTDOWN0 11/15/2002 SINGLE CONTROL ROD DRIVE (CRD) REMOVAL -REFUELING 0 11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL  
-COLD SHUTDOWN 0 11/15/2002 SINGLE CONTROL ROD DRIVE (CRD) REMOVAL -REFUELING 0 11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL  
-REFUELING 1 04/18/2006 CONTROL ROD TESTING -OPERATING 1 04/12/2006 SHUTDOWN MARGIN (SDM) TEST -REFUELING Page~ of 8 Report Date: 02/20/14Page 8 of .8Report Date: 02/20/14 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionTOC Table of Contents 22B 2.0 SAFETY LIMITS BASESPage B 2.0-1 0Page TS / B 2.0-2 3Page TS / B 2.0-3 5Page TS / B 2.0-4 3Page TS / B 2.0-5 5Page TS / B 2.0-6 1Pages TS / B 2.0-7 through TS / B 2.0-9 1B 3.0 LCO AND SR APPLICABILITY BASESPage TS / B 3.0-1 1Pages TS I B 3.0-2 through TS / B 3.0-4 0Pages TS / B 3.0-5 through TS / B 3.0-7 1Page TS / B 3.0-8 3Pages TS / B 3.0-9 through TS / B 3.0-11 2Page TS / B 3.0-1 Ia 0Page TS / B 3.0-12 1Pages TS / B 3.0-13 through TS / B 3.0-15 2Pages TS / B 3.0-16 and TS / B 3.0-17 0B 3.1 REACTIVITY CONTROL BASESPages B 3.1-1 through B 3.1-4 0Page TS / B 3.1-5 1Pages TS / B 3.1-6 and TS / B 3.1-7 2Pages B 3.1-8 through B 3.1-13 0Page TS / B 3.1-14 1Page B 3.1-15 0Page TS / B 3.1-16 1Pages B 3.1-17 through B 3.1-19 0Pages TS / B 3.1-20 and TS / B 3.1-21 1Page TS / B 3.1-22 0Page TS / B 3.1-23 1Page TS / B 3.1-24 0Pages TS / B 3.1-25 through TS / B 3.1-27 1Page TS / B 3.1-28 2Page TS / B 3.1-29 1Pages B 3.1-30 through B 3.1-33 0Pages TS / B 3.3-34 through TS / B 3.3-36 1Pages TS / B 3.1-37 and TS / B 3.1-38 2Pages TS / B 3.1-39 and TS / B 3.1-40 2Page TS / B 3.1-40a 0Pages TS / B 3.1-41 and TS / B 3.1-42 2SUSQUEHANNA
-REFUELING 1 04/18/2006 CONTROL ROD TESTING -OPERATING 1 04/12/2006 SHUTDOWN MARGIN (SDM) TEST -REFUELING Page~ of 8 Report Date: 02/20/14 Page 8 of .8 Report Date: 02/20/14 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision TOC Table of Contents 22 B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0 Page TS / B 2.0-2 3 Page TS / B 2.0-3 5 Page TS / B 2.0-4 3 Page TS / B 2.0-5 5 Page TS / B 2.0-6 1 Pages TS / B 2.0-7 through TS / B 2.0-9 1 B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1 Pages TS I B 3.0-2 through TS / B 3.0-4 0 Pages TS / B 3.0-5 through TS / B 3.0-7 1 Page TS / B 3.0-8 3 Pages TS / B 3.0-9 through TS / B 3.0-11 2 Page TS / B 3.0-1 Ia 0 Page TS / B 3.0-12 1 Pages TS / B 3.0-13 through TS / B 3.0-15 2 Pages TS / B 3.0-16 and TS / B 3.0-17 0 B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0 Page TS / B 3.1-5 1 Pages TS / B 3.1-6 and TS / B 3.1-7 2 Pages B 3.1-8 through B 3.1-13 0 Page TS / B 3.1-14 1 Page B 3.1-15 0 Page TS / B 3.1-16 1 Pages B 3.1-17 through B 3.1-19 0 Pages TS / B 3.1-20 and TS / B 3.1-21 1 Page TS / B 3.1-22 0 Page TS / B 3.1-23 1 Page TS / B 3.1-24 0 Pages TS / B 3.1-25 through TS / B 3.1-27 1 Page TS / B 3.1-28 2 Page TS / B 3.1-29 1 Pages B 3.1-30 through B 3.1-33 0 Pages TS / B 3.3-34 through TS / B 3.3-36 1 Pages TS / B 3.1-37 and TS / B 3.1-38 2 Pages TS / B 3.1-39 and TS / B 3.1-40 2 Page TS / B 3.1-40a 0 Pages TS / B 3.1-41 and TS / B 3.1-42 2 SUSQUEHANNA
-UNIT 1 TS I B LOES-1 Revision 113SUSQUEHANNA
-UNIT 1 TS I B LOES-1 Revision 113 SUSQUEHANNA
-UNIT 1TS / B LOES-1Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPage TS / B 3.1.43 1Page TS / B 3.1-44 0Page TS / B 3.1-45 3Pages TS / B 3.1-46 t hrough TS / B 3.1-49 1Page TS / B 3.1-50 0Page TS / B 3.1-51 3B 3.2 POWER DISTRIBUTION LIMITS BASESPage TS / B 3.2-1 2Pages TS / B 3.2-2 and TS / B 3.2-3 3Pages TS / B 3.2-4 and TS / B 3.2-5 2Page TS / B 3.2-6 3Page B 3.2-7 1Pages TS / B 3.2-8 and TS / B 3.2-9 3Page TS / B 3.2.10 2Page TS / B 3.2-11 3Page TS / B 3.2-12 1Page TS / B 3.2-13 2B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1Page TS / B 3.3-5 2Page TS / B 3.3-6 1Page TS / B 3.3-7 3Page TS / B 3.3-7a 1Page TS / B 3.3-8 5Pages TS / B 3.3-9 through TS / B 3.3-12 3Pages TS / B 3.3-12a 1Pages TS / B 3.3-12b and TS / B 3.3-12c 0Page TS / B 3.3-13 1Page TS / B 3.3-14 3Pages TS / B 3.3-15 and TS / B 3.3-16 1Pages TS / B 3.3-17 and TS / B 3.3-18 4Page TS / B 3.3-19 1Pages TS / B 3.3-20 through TS / B 3.3-22 2Page TS / B 3.3-22a 0Pages TS / B 3.3-23 and TS / B 3.3-24 2Pages TS / B 3.3-24a and TS / B 3.3-24b 0Page TS / B 3.3-25 3Page TS / B 3.3-26 2Page TS / B 3.3-27 1Pages TS / B 3.3-28 through TS / B 3.3-30 3Page TS / B 3.3-30a 0SUSQUEHANNA
-UNIT 1 TS / B LOES-1 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.1.43 1 Page TS / B 3.1-44 0 Page TS / B 3.1-45 3 Pages TS / B 3.1-46 t hrough TS / B 3.1-49 1 Page TS / B 3.1-50 0 Page TS / B 3.1-51 3 B 3.2 POWER DISTRIBUTION LIMITS BASES Page TS / B 3.2-1 2 Pages TS / B 3.2-2 and TS / B 3.2-3 3 Pages TS / B 3.2-4 and TS / B 3.2-5 2 Page TS / B 3.2-6 3 Page B 3.2-7 1 Pages TS / B 3.2-8 and TS / B 3.2-9 3 Page TS / B 3.2.10 2 Page TS / B 3.2-11 3 Page TS / B 3.2-12 1 Page TS / B 3.2-13 2 B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1 Page TS / B 3.3-5 2 Page TS / B 3.3-6 1 Page TS / B 3.3-7 3 Page TS / B 3.3-7a 1 Page TS / B 3.3-8 5 Pages TS / B 3.3-9 through TS / B 3.3-12 3 Pages TS / B 3.3-12a 1 Pages TS / B 3.3-12b and TS / B 3.3-12c 0 Page TS / B 3.3-13 1 Page TS / B 3.3-14 3 Pages TS / B 3.3-15 and TS / B 3.3-16 1 Pages TS / B 3.3-17 and TS / B 3.3-18 4 Page TS / B 3.3-19 1 Pages TS / B 3.3-20 through TS / B 3.3-22 2 Page TS / B 3.3-22a 0 Pages TS / B 3.3-23 and TS / B 3.3-24 2 Pages TS / B 3.3-24a and TS / B 3.3-24b 0 Page TS / B 3.3-25 3 Page TS / B 3.3-26 2 Page TS / B 3.3-27 1 Pages TS / B 3.3-28 through TS / B 3.3-30 3 Page TS / B 3.3-30a 0 SUSQUEHANNA
-UNIT 1 TS I B LOES-2 Revision 113SUSQUEHANNA
-UNIT 1 TS I B LOES-2 Revision 113 SUSQUEHANNA
-UNIT 1TS / B LOES-2Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPage TS / B 3.3-31 4Page TS / B 3.3-32 5Pages TS / B 3.3-32a 0Page TS / B 3.3-32b 1Page TS / B 3.3-33 5Page TS / B 3.3-33a 0Page TS / B 3.3-34 1Pages TS / B 3.3-35 and TS / B 3.3-36 2Pages TS / B 3.3-37 and TS / B 3.3-38 1Page TS / B 3.3-39 2Pages TS / B 3.3-40 through TS / B 3.3-43 1Page TS / B 3.3-44 4Pages TS / B 3.3-44a and TS / B 3.3-44b 0Page TS / B 3.3-45 3Pages TS / B 3.3-45a and TS / B 3.3-45b 0Page TS / B 3.3-46 3Pages TS / B 3.3-47 2Pages TS / B 3.3-48 through TS / B 3.3-51 3Pages TS / B 3.3-52 and TS / B 3.3-53 2Page TS / B 3-3-53a 0Page TS / B 3.3-54 4Page TS / B 3.3-55 2Pages TS / B 3.3-56 and TS / B 3.3-57 1Page TS / B 3.3-58 0Page TS / B 3.3-59 1Page TS / B 3.3-60 0Page TS / B 3.3-61 1Pages TS / B 3.3-62 and TS / B 3.3-63 0Pages TS / B 3.3-64 and TS / B 3.3-65 2Page TS / B 3.3-66 4Page TS / B 3.3-67 3Page TS / B 3.3-68 4Page TS / B 3.3-69 5Pages TS / B 3.3-70 4Page TS / B 3.3-71 3Pages TS / B 3.3-72 and TS / B 3.3-73 2Page TS / B 3.3-74 3Page TS / B 3.3-75 2Page TS / B 3.3-75a 6Page TS / B 3.3-75b 7Page TS / B 3.3-75c 6SUSQUEHANNA
-UNIT 1 TS / B LOES-2 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.3-31 4 Page TS / B 3.3-32 5 Pages TS / B 3.3-32a 0 Page TS / B 3.3-32b 1 Page TS / B 3.3-33 5 Page TS / B 3.3-33a 0 Page TS / B 3.3-34 1 Pages TS / B 3.3-35 and TS / B 3.3-36 2 Pages TS / B 3.3-37 and TS / B 3.3-38 1 Page TS / B 3.3-39 2 Pages TS / B 3.3-40 through TS / B 3.3-43 1 Page TS / B 3.3-44 4 Pages TS / B 3.3-44a and TS / B 3.3-44b 0 Page TS / B 3.3-45 3 Pages TS / B 3.3-45a and TS / B 3.3-45b 0 Page TS / B 3.3-46 3 Pages TS / B 3.3-47 2 Pages TS / B 3.3-48 through TS / B 3.3-51 3 Pages TS / B 3.3-52 and TS / B 3.3-53 2 Page TS / B 3-3-53a 0 Page TS / B 3.3-54 4 Page TS / B 3.3-55 2 Pages TS / B 3.3-56 and TS / B 3.3-57 1 Page TS / B 3.3-58 0 Page TS / B 3.3-59 1 Page TS / B 3.3-60 0 Page TS / B 3.3-61 1 Pages TS / B 3.3-62 and TS / B 3.3-63 0 Pages TS / B 3.3-64 and TS / B 3.3-65 2 Page TS / B 3.3-66 4 Page TS / B 3.3-67 3 Page TS / B 3.3-68 4 Page TS / B 3.3-69 5 Pages TS / B 3.3-70 4 Page TS / B 3.3-71 3 Pages TS / B 3.3-72 and TS / B 3.3-73 2 Page TS / B 3.3-74 3 Page TS / B 3.3-75 2 Page TS / B 3.3-75a 6 Page TS / B 3.3-75b 7 Page TS / B 3.3-75c 6 SUSQUEHANNA
-UNIT I TS/BLOES-3 Revision 113SUSQUEHANNA
-UNIT I TS/BLOES-3 Revision 113 SUSQUEHANNA
-UNIT 1TS / B LOES-3Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPages B 3.3-76 through 3.3-77 0Page TS / B 3.3-78 1Pages B 3.3-79 through B 3.3-81 0Page B 3.3-82 1Page B 3.3-83 0Pages B '3.3-84 and B 3.3-85 1Page B 3.3-86 0Page B 3.3-87 1Page B 3.3-88 0Page B 3.3-89 1Page TS / B 3.3-90 1Page B 3.3-91 0Pages TS / B 3.3-92 through TS / B 3.3-100 1Pages TS / B 3.3-101 through TS / B 3.3-103 0Page TS / B 3.3-104 2Pages TS / B 3.3-105 and TS / B 3.3-106 0Page TS / B 3.3-107 1Page TS I B 3.3-108 0Page TS / B 3.3-109 1Pages TS / B 3.3-110 and TS/B 3.3-111 0Pages TS / B 3.3-112 and TS / B 3.3-112a 1Pages TS / B 3.3-113 through TS / B 3.3-115 1Page TS / B 3.3-116 3Page TS / B 3.3-117 1Pages TS / B 3.3-118 through TS / B 3.3-122 0Pages TS / B 3.3-123 and TS / B 3.3-124 1Page TS / B 3.3-124a 0Page TS / B 3.3-125 0Pages TS / B 3.3-126 and TS / B 3.3-127 1Pages TS I B 3.3-128 through TS/ B 3.3-130 0Page TS / B 3.3-131 1Pages TS / B 3.3-132 through TS / B 3.3-134 0Pages B 3.3-135 through B 3.3-137 0Page TS / B 3.3-138 1Pages B 3.3-139 through B 3.3-149 0Pages TS / B 3.3-150 and TS / B 3.3-151 1Pages TS / B 3.3-152 through TS / B 3.3-154 2Page TS / B 3.3-155 1Pages TS / B 3.3-156 through TS / B 3.3-158 2Pages TS / B 3.3-159 through TS / B 3.3-162 1Page TS / B 3.3-163 2Page TS / B 3.3-164 1Pages TS / B 3.3-165 through TS / B 3.3-167 2SUSQUEHANNA-UNITI TSIBLOES-4 Revision 113SUSQUEHANNA
-UNIT 1 TS / B LOES-3 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages B 3.3-76 through 3.3-77 0 Page TS / B 3.3-78 1 Pages B 3.3-79 through B 3.3-81 0 Page B 3.3-82 1 Page B 3.3-83 0 Pages B '3.3-84 and B 3.3-85 1 Page B 3.3-86 0 Page B 3.3-87 1 Page B 3.3-88 0 Page B 3.3-89 1 Page TS / B 3.3-90 1 Page B 3.3-91 0 Pages TS / B 3.3-92 through TS / B 3.3-100 1 Pages TS / B 3.3-101 through TS / B 3.3-103 0 Page TS / B 3.3-104 2 Pages TS / B 3.3-105 and TS / B 3.3-106 0 Page TS / B 3.3-107 1 Page TS I B 3.3-108 0 Page TS / B 3.3-109 1 Pages TS / B 3.3-110 and TS/B 3.3-111 0 Pages TS / B 3.3-112 and TS / B 3.3-112a 1 Pages TS / B 3.3-113 through TS / B 3.3-115 1 Page TS / B 3.3-116 3 Page TS / B 3.3-117 1 Pages TS / B 3.3-118 through TS / B 3.3-122 0 Pages TS / B 3.3-123 and TS / B 3.3-124 1 Page TS / B 3.3-124a 0 Page TS / B 3.3-125 0 Pages TS / B 3.3-126 and TS / B 3.3-127 1 Pages TS I B 3.3-128 through TS/ B 3.3-130 0 Page TS / B 3.3-131 1 Pages TS / B 3.3-132 through TS / B 3.3-134 0 Pages B 3.3-135 through B 3.3-137 0 Page TS / B 3.3-138 1 Pages B 3.3-139 through B 3.3-149 0 Pages TS / B 3.3-150 and TS / B 3.3-151 1 Pages TS / B 3.3-152 through TS / B 3.3-154 2 Page TS / B 3.3-155 1 Pages TS / B 3.3-156 through TS / B 3.3-158 2 Pages TS / B 3.3-159 through TS / B 3.3-162 1 Page TS / B 3.3-163 2 Page TS / B 3.3-164 1 Pages TS / B 3.3-165 through TS / B 3.3-167 2 SUSQUEHANNA-UNITI TSIBLOES-4 Revision 113 SUSQUEHANNA
-UNIT 10TS / B LOES-4Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPages TS / B 3.3-168 and TS / B 3.3-169 1Page TS / B 3.3-170 2Pages TS / B 3.3-171 through TS / B 3.3-177 1Pages TS / B 3.3-178 through TS / B 3.3-179a 2Pages TS / B 3.3-179b and TS / B 3.3-179c 0Page TS / B 3.3-180 1Page TS / B 3.3-181 3Page TS / B 3.3-182 1Page TS / B 3.3-183 2Page TS / B 3.3-184 1Page TS / B 3.3-185 4Page TS / B 3.3-186 1Pages TS / B 3.3-187 and TS / B 3.3-188 2Pages TS / B 3.3-189 through TS / B 3.3-191 1Page TS / B 3.3-192 0Page TS / B 3.3-193 1Pages TS / B 3.3-194 and TS / B 3.3-195 0Page TS / B 3.3-196 2Pages TS / B 3.3-197 through TS / B 3.3-204 0Page TS / B 3.3-205 1Pages B 3.3-206 through B 3.3-209 0Page TS / B 3.3-210 1Pages B 3.3-211 through B 3.3-219 0B 3.4 REACTOR COOLANT SYSTEM BASESPages B 3.4-1 and B 3.4-2 0Pages TS / B 3.4-3 and Page TS / B 3.4-4 4Page TS / B 3.4-5 3Pages TS / B 3.4-6 through TS / B 3.4-9 2Page TS / B 3.4-10 1Pages TS / 3.4-11 and TS / B 3.4-12 0Page TS / B 3.4-13 2Page TS / B 3.4-14 1Page TS / B 3.4-15 2Pages TS / B 3.4-16 and TS / B 3.4-17 4Page TS / B 3.4-18 2Pages B 3.4-19 through B 3.4-27 0Pages TS / B 3.4-28 and TS / B 3.4-29 1Page TS / B 3.4-30 2Page TS / B 3.4-31 1Pages TS / B 3.4-32 and TS / B 3.4-33 2Page TS / B 3.4-34 1Page TS / B 3.4-34a 0Pages TS / B 3.4-35 and TS / B 3.4-36 1SUSQUEHANNA
-UNIT 1 0 TS / B LOES-4 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages TS / B 3.3-168 and TS / B 3.3-169 1 Page TS / B 3.3-170 2 Pages TS / B 3.3-171 through TS / B 3.3-177 1 Pages TS / B 3.3-178 through TS / B 3.3-179a 2 Pages TS / B 3.3-179b and TS / B 3.3-179c 0 Page TS / B 3.3-180 1 Page TS / B 3.3-181 3 Page TS / B 3.3-182 1 Page TS / B 3.3-183 2 Page TS / B 3.3-184 1 Page TS / B 3.3-185 4 Page TS / B 3.3-186 1 Pages TS / B 3.3-187 and TS / B 3.3-188 2 Pages TS / B 3.3-189 through TS / B 3.3-191 1 Page TS / B 3.3-192 0 Page TS / B 3.3-193 1 Pages TS / B 3.3-194 and TS / B 3.3-195 0 Page TS / B 3.3-196 2 Pages TS / B 3.3-197 through TS / B 3.3-204 0 Page TS / B 3.3-205 1 Pages B 3.3-206 through B 3.3-209 0 Page TS / B 3.3-210 1 Pages B 3.3-211 through B 3.3-219 0 B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0 Pages TS / B 3.4-3 and Page TS / B 3.4-4 4 Page TS / B 3.4-5 3 Pages TS / B 3.4-6 through TS / B 3.4-9 2 Page TS / B 3.4-10 1 Pages TS / 3.4-11 and TS / B 3.4-12 0 Page TS / B 3.4-13 2 Page TS / B 3.4-14 1 Page TS / B 3.4-15 2 Pages TS / B 3.4-16 and TS / B 3.4-17 4 Page TS / B 3.4-18 2 Pages B 3.4-19 through B 3.4-27 0 Pages TS / B 3.4-28 and TS / B 3.4-29 1 Page TS / B 3.4-30 2 Page TS / B 3.4-31 1 Pages TS / B 3.4-32 and TS / B 3.4-33 2 Page TS / B 3.4-34 1 Page TS / B 3.4-34a 0 Pages TS / B 3.4-35 and TS / B 3.4-36 1 SUSQUEHANNA
-UNIT I TSIBLOES-5 Revision 113SUSQUEHANNA
-UNIT I TSIBLOES-5 Revision 113 SUSQUEHANNA
-UNIT 1TS / B LOES-5Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPage TS / B 3.4-37 2Page TS / B 3.4-38 1Pages B 3.4-39 and B 3.4-40 0Page TS / B 3.4-41 2Pages TS / B 3.4-42 through TS / B 3.4-45 0Page TS / B 3.4-46 1Pages TS B 3.4-47 and TS / B 3.4-48 0Page TS / B 3.4-49 3Page TS / B 3.4-50 1Page TS / B 3.4-51 3Page TS / B 3.4-52 2Page TS / B 3.4-53 1Pages TS / B 3.4-54 through TS / B 3.4-56 2Page TS / B 3.4-57 3Pages TS / B 3.4-58 through TS / B 3.4-60 1B 3.5 ECCS AND RCIC BASESPages B 3.5-1 and B 3.5-2 0Page TS / B 3.5-3 2Page TS / B 3.5-4 1Page TS / B 3.5-5 2Page TS / B 3.5-6 1Pages B 3.5-7 through B 3.5-10 0Page TS / B 3.5-11 1Page TS / B 3.5-12 0Page TS / B 3.5-13 1Pages TS / B 3.5-14 and TS / B 3.5-15 0Pages TS / B 3.5-16 through TS / B 3.5-18 1Pages B 3.5-19 through B 3.5-24 0Page TS / B 3.5-25 through TS / B 3.5-27 1Page TS / B 3.5-28 0Page TS I B 3.5-29 1Pages TS / B 3.5-30 and TS / B 3.5-31 0B 3.6 CONTAINMENT SYSTEMS BASESPage TS / B 3.6-1 2Page TS / B 3.6-1a 3Page TS / B 3.6-2 4Page TS / B 3.6-3 3Page TS / B 3.6-4 4Pages TS / B 3.6-5 and TS I B 3.6-6 3Page TS / B 3.6-6a 2Page TS / B 3.6-6b 3Page TS / B 3.6-6c 0Page B 3.6-7 0SUSQUEHANNA
-UNIT 1 TS / B LOES-5 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.4-37 2 Page TS / B 3.4-38 1 Pages B 3.4-39 and B 3.4-40 0 Page TS / B 3.4-41 2 Pages TS / B 3.4-42 through TS / B 3.4-45 0 Page TS / B 3.4-46 1 Pages TS B 3.4-47 and TS / B 3.4-48 0 Page TS / B 3.4-49 3 Page TS / B 3.4-50 1 Page TS / B 3.4-51 3 Page TS / B 3.4-52 2 Page TS / B 3.4-53 1 Pages TS / B 3.4-54 through TS / B 3.4-56 2 Page TS / B 3.4-57 3 Pages TS / B 3.4-58 through TS / B 3.4-60 1 B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0 Page TS / B 3.5-3 2 Page TS / B 3.5-4 1 Page TS / B 3.5-5 2 Page TS / B 3.5-6 1 Pages B 3.5-7 through B 3.5-10 0 Page TS / B 3.5-11 1 Page TS / B 3.5-12 0 Page TS / B 3.5-13 1 Pages TS / B 3.5-14 and TS / B 3.5-15 0 Pages TS / B 3.5-16 through TS / B 3.5-18 1 Pages B 3.5-19 through B 3.5-24 0 Page TS / B 3.5-25 through TS / B 3.5-27 1 Page TS / B 3.5-28 0 Page TS I B 3.5-29 1 Pages TS / B 3.5-30 and TS / B 3.5-31 0 B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2 Page TS / B 3.6-1a 3 Page TS / B 3.6-2 4 Page TS / B 3.6-3 3 Page TS / B 3.6-4 4 Pages TS / B 3.6-5 and TS I B 3.6-6 3 Page TS / B 3.6-6a 2 Page TS / B 3.6-6b 3 Page TS / B 3.6-6c 0 Page B 3.6-7 0 SUSQUEHANNA
-UNIT 1 TS/BLOES-6 Revision 113SUSQUEHANNA
-UNIT 1 TS/BLOES-6 Revision 113 SUSQUEHANNA
-UNIT 1TS / B LOES-6Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPage B 3.6-8 1Pages B 3.6-9 through B 3.6-14 0Page TS / B 3.6-15 3Page TS / B 3.6-15a 0Page TS / B 3.6-15b 2Pages TS / B 3.6-16 and TS / B 3.6-17 2Page TS J B 3.6-17a I 1Pages TS / B 3.6-18 and TS / B 3.6-19 0Page TS / B 3.6-20 1Page TS / B 3.6-21 2Page TS I B 3.6-22 1Page TS / B 3.6-22a 0Page TS / B 3.6-23 1Pages TS / B 3.6-24 and TS / B 3.6-25 0Pages TS / B 3.6-26 and TS / B 3.6-27 2Page TS / B 3.6-28 7Page TS / B 3.6-29 2Page TS / B 3.6-30 1Page TS / B 3.6-31 3Pages TS / B 3.6-32 and TS / B 3.6-33 1Pages TS / B 3.6-34 and TS / B 3.6-35 0Page TS / B 3.6-36 1Page TS / B 3.6-37 0Page TS / B 3.6-38 3Page TS / B 3.6-39 2Page TS / B 3.6-40 6Page TS / B 3.6-40a 0Page B 3.6-41 1Pages B 3.6-42 and B 3.6-43 3Pages TS / B 3.6-44 and TS / B 3.6-45 1Page TS / B 3.6-46 2Pages TS / B 3.6-47 through TS / B 3.6-51 1Page TS / B 3.6-52 2Pages TS / B 3.6-53 through TS / B 3.6-56 0Page TS / B 3.6-57 1Page TS / 3.6-58 2Pages B 3.6-59 through B 3.6-63 0Pages TS / B 3.6-64 and TS / B 3.6-65 1Pages B 3.6-66 through B 3.6-69 0Pages TS / B 3.6-70 through TS / B 3.6-72 1Page TS / B 3.6-73 2Pages TS / B 3.6-74 and TS / B 3.6-75 1Pages B 3.6-76 and B 3.6-77 0SUSQUEHANNA
-UNIT 1 TS / B LOES-6 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page B 3.6-8 1 Pages B 3.6-9 through B 3.6-14 0 Page TS / B 3.6-15 3 Page TS / B 3.6-15a 0 Page TS / B 3.6-15b 2 Pages TS / B 3.6-16 and TS / B 3.6-17 2 Page TS J B 3.6-17a I 1 Pages TS / B 3.6-18 and TS / B 3.6-19 0 Page TS / B 3.6-20 1 Page TS / B 3.6-21 2 Page TS I B 3.6-22 1 Page TS / B 3.6-22a 0 Page TS / B 3.6-23 1 Pages TS / B 3.6-24 and TS / B 3.6-25 0 Pages TS / B 3.6-26 and TS / B 3.6-27 2 Page TS / B 3.6-28 7 Page TS / B 3.6-29 2 Page TS / B 3.6-30 1 Page TS / B 3.6-31 3 Pages TS / B 3.6-32 and TS / B 3.6-33 1 Pages TS / B 3.6-34 and TS / B 3.6-35 0 Page TS / B 3.6-36 1 Page TS / B 3.6-37 0 Page TS / B 3.6-38 3 Page TS / B 3.6-39 2 Page TS / B 3.6-40 6 Page TS / B 3.6-40a 0 Page B 3.6-41 1 Pages B 3.6-42 and B 3.6-43 3 Pages TS / B 3.6-44 and TS / B 3.6-45 1 Page TS / B 3.6-46 2 Pages TS / B 3.6-47 through TS / B 3.6-51 1 Page TS / B 3.6-52 2 Pages TS / B 3.6-53 through TS / B 3.6-56 0 Page TS / B 3.6-57 1 Page TS / 3.6-58 2 Pages B 3.6-59 through B 3.6-63 0 Pages TS / B 3.6-64 and TS / B 3.6-65 1 Pages B 3.6-66 through B 3.6-69 0 Pages TS / B 3.6-70 through TS / B 3.6-72 1 Page TS / B 3.6-73 2 Pages TS / B 3.6-74 and TS / B 3.6-75 1 Pages B 3.6-76 and B 3.6-77 0 SUSQUEHANNA
-UNIT 1TS / B LOES-7Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPage TS / B 3.6-78 1Pages B 3.6-79 and B 3.3.6-80 0Page TS / B 3.6-81 1Pages TS / B 3.6-82 and TS / B 3.6-83 0Page TS / B 3.6-84 4Page TS / B 3.6-85 2Page TS / B 3.6-86 4Pages TS / B 3.6-87 through TS / B 3.6-88a 2Page TS / B 3.6-89 5Page TS / B 3.6-90 3Page TS [ B 3.6-90a 0Pages TS / B 3.6-91 and TS / B 3.6-92 3Page TS / B 3.6-93 2Pages TS / B 3.6-94 through TS / B 3.6-96 1Page TS / B 3.6-97 2Page TS / 8 3.6-98 1Page TS / B 3.6-99 2Pages TS / B 3.6-100 and TS / B 3.6-100a 5Page TS / B 3.6-100b 3Pages TS / B 3.6-101 and TS / B 3.6-102 1Pages TS / B 3.6-103 and TS / B 3.6-104 2Page TS / B 3.6-105 3Page TS / B 3.6-106 2Page TS / B 3.6-107 3B 3.7 PLANT SYSTEMS BASESPages TS / B 3.7-1 3Page TS /B 3.7-2 4Pages TS / B 3.7-3 through TS / B 3.7-5 3Page TS / B 3.7-5a IPage TS / B 3.7-6 3Page TS / B 3.7-6a 2Page TS / B 3.7-6b 1Page TS / B 3.7-6c 2Page TS / B 3.7-7 3Page TS / B 3.7-8 2Pages TS / B 3.7-9 through TS / B 3.7-11 1Pages TS / B 3.7-12 and TS / B 3.7-13 2Pages TS / B 3.7-14 through TS / B 3.7-18 3Page TS / B 3.7-18a 1Pages TS I B 3.7-18b through TS / B 3.7-18e 0Pages TS / B 3.7-19 through TS / B 3.7-23 1Page TS / B 3.7-24 1SUSQUEHANNA
-UNIT 1 TS / B LOES-7 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.6-78 1 Pages B 3.6-79 and B 3.3.6-80 0 Page TS / B 3.6-81 1 Pages TS / B 3.6-82 and TS / B 3.6-83 0 Page TS / B 3.6-84 4 Page TS / B 3.6-85 2 Page TS / B 3.6-86 4 Pages TS / B 3.6-87 through TS / B 3.6-88a 2 Page TS / B 3.6-89 5 Page TS / B 3.6-90 3 Page TS [ B 3.6-90a 0 Pages TS / B 3.6-91 and TS / B 3.6-92 3 Page TS / B 3.6-93 2 Pages TS / B 3.6-94 through TS / B 3.6-96 1 Page TS / B 3.6-97 2 Page TS / 8 3.6-98 1 Page TS / B 3.6-99 2 Pages TS / B 3.6-100 and TS / B 3.6-100a 5 Page TS / B 3.6-100b 3 Pages TS / B 3.6-101 and TS / B 3.6-102 1 Pages TS / B 3.6-103 and TS / B 3.6-104 2 Page TS / B 3.6-105 3 Page TS / B 3.6-106 2 Page TS / B 3.6-107 3 B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 3 Page TS /B 3.7-2 4 Pages TS / B 3.7-3 through TS / B 3.7-5 3 Page TS / B 3.7-5a I Page TS / B 3.7-6 3 Page TS / B 3.7-6a 2 Page TS / B 3.7-6b 1 Page TS / B 3.7-6c 2 Page TS / B 3.7-7 3 Page TS / B 3.7-8 2 Pages TS / B 3.7-9 through TS / B 3.7-11 1 Pages TS / B 3.7-12 and TS / B 3.7-13 2 Pages TS / B 3.7-14 through TS / B 3.7-18 3 Page TS / B 3.7-18a 1 Pages TS I B 3.7-18b through TS / B 3.7-18e 0 Pages TS / B 3.7-19 through TS / B 3.7-23 1 Page TS / B 3.7-24 1 SUSQUEHANNA
-UNIT 1TS / B LOES-8Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionPages TS / B 3.7-25 and TS / B 3.7-26 0Pages TS / B 3.7-27 through TS / B 3.7-29 5Page TS / B 3.7-30 2Page TS / B 3.7-31 1Page TS / B 3.7-32 0Page TS / B 3.7-33 1Pages TS / B 3.7-34 through TS / B 3.7-37 0B 3.8 ELECTRICAL POWER SYSTEMS BASESPage TS / B 3.8-1 3Pages TS / B 3.8-2 and TS / B 3.8-3 2Page TS / B 3.8-4 3Pages TS / B 3.8-4a and TS / B 3.8-4b 0Page TS / B 3.8-5 5Page TS / B 3.8-6 3Pages TS / B 3.8-7 through TS/B 3.8-8 2Page TS / B 3.8-9 4Page TS / B 3.8-10 3Pages TS / B 3.8-11 and TS / B 3.8-17 2Page TS / B 3.8-18 3Pages TS / B 3.8-19 through TS / B 3.8-21 2Pages TS / B 3.8-22 and TS / B 3.8-23 3Pages TS / B 3.8-24 through TS / B 3.8-37 2Pages B 3.8-38 through B 3.8-44 0Page TS / B 3.8-45 3Pages TS / B 3.8-46 through TS / B 3.8-48 0Pages TS / B 3.8-49 and TS / B 3.8-50 3Page TS / B 3.8-51 1Page TS / B 3.8-52 0Page TS / B 3.8-53 1Pages TS / B 3.8-54 through TS / B 3.8-57 2Pages TS / B 3.8-58 through TS / B 3.8-61 3Pages TS / B 3.8-62 and TS / B 3.8-63 5Page TS / B 3.8-64 4Page TS / B 3.8-65 5Pages TS / B 3.8-66 through TS / B 3.8-77 1Pages TS / B 3.8-77A through TS / B 3.8-77C 0Pages B 3.8-78 through B 3.8-80 0Page TS / B 3.8-81 1Pages B 3.8-82 through B 3.8-90 0SUSQUEHANNA
-UNIT 1 TS / B LOES-8 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages TS / B 3.7-25 and TS / B 3.7-26 0 Pages TS / B 3.7-27 through TS / B 3.7-29 5 Page TS / B 3.7-30 2 Page TS / B 3.7-31 1 Page TS / B 3.7-32 0 Page TS / B 3.7-33 1 Pages TS / B 3.7-34 through TS / B 3.7-37 0 B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 3 Pages TS / B 3.8-2 and TS / B 3.8-3 2 Page TS / B 3.8-4 3 Pages TS / B 3.8-4a and TS / B 3.8-4b 0 Page TS / B 3.8-5 5 Page TS / B 3.8-6 3 Pages TS / B 3.8-7 through TS/B 3.8-8 2 Page TS / B 3.8-9 4 Page TS / B 3.8-10 3 Pages TS / B 3.8-11 and TS / B 3.8-17 2 Page TS / B 3.8-18 3 Pages TS / B 3.8-19 through TS / B 3.8-21 2 Pages TS / B 3.8-22 and TS / B 3.8-23 3 Pages TS / B 3.8-24 through TS / B 3.8-37 2 Pages B 3.8-38 through B 3.8-44 0 Page TS / B 3.8-45 3 Pages TS / B 3.8-46 through TS / B 3.8-48 0 Pages TS / B 3.8-49 and TS / B 3.8-50 3 Page TS / B 3.8-51 1 Page TS / B 3.8-52 0 Page TS / B 3.8-53 1 Pages TS / B 3.8-54 through TS / B 3.8-57 2 Pages TS / B 3.8-58 through TS / B 3.8-61 3 Pages TS / B 3.8-62 and TS / B 3.8-63 5 Page TS / B 3.8-64 4 Page TS / B 3.8-65 5 Pages TS / B 3.8-66 through TS / B 3.8-77 1 Pages TS / B 3.8-77A through TS / B 3.8-77C 0 Pages B 3.8-78 through B 3.8-80 0 Page TS / B 3.8-81 1 Pages B 3.8-82 through B 3.8-90 0 SUSQUEHANNA
-UNIT 1 TSIB LOES-9 Revision 113.SUSQUEHANNA  
-UNIT 1 TSIB LOES-9 Revision 113.SUSQUEHANNA  
-UNIT 1TS I B LOES-9Revision 113 SUSQUEHANNA STEAM ELECTRIC STATIONLIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title RevisionB 3.9 REFUELING OPERATIONS BASESPages TS / B 3.9-1 and TS / B 3.9-1a IPages TS / B 3.9-2 through TS / B 3.9-5 1Pages TS / B 3.9-6 through TS / B 3.9-8 0Pages B 3.9-9 through B 3.9-18 0Pages TS / B 3.9-19 through TS / B 3.9-21 1Pages B 3.9-22 through B 3.9-30 0B 3.10 SPECIAL OPERATIONS BASESPage TS / B 3.10-1 2Pages TS / B 3.10-2 through TS I B 3.10-5 1Pages B 3.10-6 through B 3.10-31 0Page TS / B 3.10-32 2Page B 3.10-33 0Page TS / B 3.10-34 1Pages B 3.10-35 and B 3.10-36 0Page TS / B 3.10-37 1Page TS / B 3.10-38 2TSB1 Text LOES.doc2/11/2014 SUSQUEHANNA  
-UNIT 1 TS I B LOES-9 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a I Pages TS / B 3.9-2 through TS / B 3.9-5 1 Pages TS / B 3.9-6 through TS / B 3.9-8 0 Pages B 3.9-9 through B 3.9-18 0 Pages TS / B 3.9-19 through TS / B 3.9-21 1 Pages B 3.9-22 through B 3.9-30 0 B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2 Pages TS / B 3.10-2 through TS I B 3.10-5 1 Pages B 3.10-6 through B 3.10-31 0 Page TS / B 3.10-32 2 Page B 3.10-33 0 Page TS / B 3.10-34 1 Pages B 3.10-35 and B 3.10-36 0 Page TS / B 3.10-37 1 Page TS / B 3.10-38 2 TSB1 Text LOES.doc 2/11/2014 SUSQUEHANNA  
-UNIT 1TS / B LOES-10Revision 113 PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6B 3.4 REACTOR COOLANT SYSTEM (RCS)B 3.4.6 RCS Leakage Detection Instrumentation BASESBACKGROUND GDC 30 of 10 CFR 50, Appendix A (Ref. 1), requires means for detecting and, to the extent practical, identifying the location of the source of RCSLEAKAGE.
-UNIT 1 TS / B LOES-10 Revision 113 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 B 3.4 REACTOR COOLANT SYSTEM (RCS)B 3.4.6 RCS Leakage Detection Instrumentation BASES BACKGROUND GDC 30 of 10 CFR 50, Appendix A (Ref. 1), requires means for detecting and, to the extent practical, identifying the location of the source of RCS LEAKAGE. Regulatory Guide 1.45, Revision 0, (Ref. 2) describes acceptable methods for selecting leakage detection systems.Limits on LEAKAGE from the reactor coolant pressure boundary (RCPB)are required so that appropriate action can be taken before the integrity of the RCPB is impaired (Ref. 2). Leakage detection systems for the RCS are provided to alert the operators when leakage rates above normal background levels are detected and also to supply quantitative measurement of leakage rates. The Bases for LCO 3.4.4, "RCS Operational LEAKAGE," discuss the limits on RCS LEAKAGE rates.Systems for separating the LEAKAGE of an identified source from an unidentified source are necessary to provide prompt and quantitative information to the operators to permit them to take immediate corrective action.LEAKAGE from the RCPB inside the drywell is detected by at least one of two or three independently monitored variables, such as sump level changes and drywell gaseous and particulate radioactivity levels. The primary means of quantifying LEAKAGE in the drywell is the drywell floor drain sump monitoring system which consists of two drywell floor drain sump level Channels.
Regulatory Guide 1.45, Revision 0, (Ref. 2) describes acceptable methods for selecting leakage detection systems.Limits on LEAKAGE from the reactor coolant pressure boundary (RCPB)are required so that appropriate action can be taken before the integrity ofthe RCPB is impaired (Ref. 2). Leakage detection systems for the RCSare provided to alert the operators when leakage rates above normalbackground levels are detected and also to supply quantitative measurement of leakage rates. The Bases for LCO 3.4.4, "RCSOperational LEAKAGE,"
Both Channels are required to be Operable to satisfy the LCO.The drywell floor drain sump monitoring system monitors the LEAKAGE collected in the floor drain sump. This unidentified LEAKAGE consists of LEAKAGE from control rod drives, valve flanges or packings, floor drains, the Closed Cooling Water System, and drywell air cooling unit condensate drains, and any LEAKAGE not collected in the drywell equipment drain tank.The level of each drywell sump is continuously recorded in the Main Control Room. The change in (continued)
discuss the limits on RCS LEAKAGE rates.Systems for separating the LEAKAGE of an identified source from anunidentified source are necessary to provide prompt and quantitative information to the operators to permit them to take immediate corrective action.LEAKAGE from the RCPB inside the drywell is detected by at least one oftwo or three independently monitored variables, such as sump levelchanges and drywell gaseous and particulate radioactivity levels. Theprimary means of quantifying LEAKAGE in the drywell is the drywell floordrain sump monitoring system which consists of two drywell floor drainsump level Channels.
Both Channels are required to be Operable tosatisfy the LCO.The drywell floor drain sump monitoring system monitors the LEAKAGEcollected in the floor drain sump. This unidentified LEAKAGE consists ofLEAKAGE from control rod drives, valve flanges or packings, floor drains,the Closed Cooling Water System, and drywell air cooling unit condensate drains, and any LEAKAGE not collected in the drywell equipment draintank.The level of each drywell sump is continuously recorded in the MainControl Room. The change in(continued)
SUSQUEHANNA  
SUSQUEHANNA  
-UNIT 1TS I B 3.4-30Revision 2
-UNIT 1 TS I B 3.4-30 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES BACKGROUND (continued) sump level per unit time determines the leak rate and is calculated from the recorder.The floor drain sump level indicators have switches that start and stop the sump pumps when required.
PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6BASESBACKGROUND (continued) sump level per unit time determines the leak rate and is calculated fromthe recorder.
If the sump fills to the high high level setpoint, an alarm sounds in the control room.The primary containment air monitoring systems continuously monitor the primary containment atmosphere for airborne particulate and gaseous radioactivity.
The floor drain sump level indicators have switches that start and stop thesump pumps when required.
A sudden increase of radioactivity, which may be attributed to RCPB steam or reactor water LEAKAGE, is annunciated in the control room.APPLICABLE SAFETY ANALYSES A threat of significant compromise to the RCPB exists if the barrier contains a crack that is large enough to propagate rapidly. LEAKAGE rate limits are set low enough to detect the LEAKAGE emitted from a single crack in the RCPB (Refs. 3 and 4). The allowed LEAKAGE rates are well below the rates predicted for critical crack sizes (Ref. 5).Therefore, these limits provide adequate response before a significant break in the RCPB can occur.RCS leakage detection instrumentation satisfies Criterion 1 of the NRC Policy Statement (Ref. 7).LCO This LCO requires instruments of diverse monitoring principles to be OPERABLE to provide confidence that small amounts of unidentified-LEAKAGE are detected in time to allow actions to place the plant in a safe condition, when RCS LEAKAGE indicates possible RCPB degradation.
If the sump fills to the high high levelsetpoint, an alarm sounds in the control room.The primary containment air monitoring systems continuously monitor theprimary containment atmosphere for airborne particulate and gaseousradioactivity.
The LCO requires two instruments to be OPERABLE.The drywell floor drain sump monitoring system is required to quantify the unidentified LEAKAGE rate from the RCS. Thus, for the system to be considered OPERABLE, the sump level monitoring portion of the system must be OPERABLE and capable of determining the leakage rate. The identification of an increase in unidentified LEAKAGE will be delayed by the time required for the unidentified LEAKAGE to travel to the drywell floor drain sump and it may take longer than one hour to detect a 1 gpm increase in unidentified LEAKAGE, depending on the origin and magnitude of the LEAKAGE. This sensitivity is acceptable for primary containment sump monitor OPERABILITY.(continued)
A sudden increase of radioactivity, which may be attributed to RCPB steam or reactor water LEAKAGE, is annunciated in the controlroom.APPLICABLE SAFETYANALYSESA threat of significant compromise to the RCPB exists if the barriercontains a crack that is large enough to propagate rapidly.
LEAKAGErate limits are set low enough to detect the LEAKAGE emitted from asingle crack in the RCPB (Refs. 3 and 4). The allowed LEAKAGE ratesare well below the rates predicted for critical crack sizes (Ref. 5).Therefore, these limits provide adequate response before a significant break in the RCPB can occur.RCS leakage detection instrumentation satisfies Criterion 1 of the NRCPolicy Statement (Ref. 7).LCOThis LCO requires instruments of diverse monitoring principles to beOPERABLE to provide confidence that small amounts of unidentified
-LEAKAGE are detected in time to allow actions to place the plant in a safecondition, when RCS LEAKAGE indicates possible RCPB degradation.
The LCO requires two instruments to be OPERABLE.
The drywell floor drain sump monitoring system is required to quantify theunidentified LEAKAGE rate from the RCS. Thus, for the system to beconsidered
: OPERABLE, the sump level monitoring portion of the systemmust be OPERABLE and capable of determining the leakage rate. Theidentification of an increase in unidentified LEAKAGE will be delayed bythe time required for the unidentified LEAKAGE to travel to the drywellfloor drain sump and it may take longer than one hour to detect a 1 gpmincrease in unidentified  
: LEAKAGE, depending on the origin andmagnitude of the LEAKAGE.
This sensitivity is acceptable for primarycontainment sump monitor OPERABILITY.
(continued)
SUSQUEHANNA  
SUSQUEHANNA  
-UNIT 1TS / B 3.4-31Revision 1
-UNIT 1 TS / B 3.4-31 Revision 1 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES LCO (continued)
PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6BASESLCO(continued)
The reactor coolant contains radioactivity that, when released to the primary containment, can be detected by the gaseous or particulate primary containment atmospheric radioactivity monitor. Only one of the two detectors is required to be OPERABLE.
The reactor coolant contains radioactivity that, when released to theprimary containment, can be detected by the gaseous or particulate primary containment atmospheric radioactivity monitor.
Radioactivity detection systems are included for monitoring both particulate and gaseous activities because of their sensitivities and rapid responses to RCS LEAKAGE, but have recognized limitations.
Only one of thetwo detectors is required to be OPERABLE.
Reactor coolant radioactivity levels will be low during initial reactor startup and for a few weeks thereafter, until activated corrosion products have been formed and fission products appear from fuel element cladding contamination or cladding defects. If there are few fuel element cladding defects and low levels of activation products, it may not be possible for the gaseous or particulate primary containment atmospheric radioactivity monitors to detect a 1 gpm increase within 1 hour during normal operation.
Radioactivity detection systems are included for monitoring both particulate and gaseousactivities because of their sensitivities and rapid responses to RCSLEAKAGE, but have recognized limitations.
However, the gaseous or particulate containment primary atmospheric radioactivity monitor is OPERABLE when it is capable of detecting a 1 gpm increase in unidentified LEAKAGE within 1 hour given an RCS activity equivalent to that assumed in the design calculations for the monitors (Reference 6).The LCO is satisfied when monitors of diverse measurement means are available.
Reactor coolant radioactivity levels will be low during initial reactor startup and for a few weeksthereafter, until activated corrosion products have been formed and fissionproducts appear from fuel element cladding contamination or claddingdefects.
Thus, the drywell floor drain sump monitoring system, in combination with a gaseous or particulate primary containment atmospheric radioactivity monitor provides an acceptable minimum.APPLICABILITY In MODES 1, 2, and 3, leakage detection systems are required to be OPERABLE to support LCO 3.4.4. This Applicability is consistent with that for LCO 3.4.4.ACTIONS A.1 With the drywell floor drain sump monitoring system inoperable, the primary containment atmospheric activity monitor will provide indication of changes in leakage.With the drywell floor drain sump monitoring system inoperable, operation may continue for 30 days. However, RCS unidentified and total LEAKAGE is still required to be determined every 12 hours (SR 3.4.4.1).The 30 day Completion Time of Required Action A.1 is acceptable, based on operating experience, considering the multiple forms of leakage detection that are still available.(continued)
If there are few fuel element cladding defects and low levels ofactivation
: products, it may not be possible for the gaseous or particulate primary containment atmospheric radioactivity monitors to detect a 1 gpmincrease within 1 hour during normal operation.  
: However, the gaseous orparticulate containment primary atmospheric radioactivity monitor isOPERABLE when it is capable of detecting a 1 gpm increase inunidentified LEAKAGE within 1 hour given an RCS activity equivalent tothat assumed in the design calculations for the monitors (Reference 6).The LCO is satisfied when monitors of diverse measurement means areavailable.
Thus, the drywell floor drain sump monitoring system, incombination with a gaseous or particulate primary containment atmospheric radioactivity monitor provides an acceptable minimum.APPLICABILITY In MODES 1, 2, and 3, leakage detection systems are required to beOPERABLE to support LCO 3.4.4. This Applicability is consistent withthat for LCO 3.4.4.ACTIONSA.1With the drywell floor drain sump monitoring system inoperable, theprimary containment atmospheric activity monitor will provide indication ofchanges in leakage.With the drywell floor drain sump monitoring system inoperable, operation may continue for 30 days. However, RCS unidentified and totalLEAKAGE is still required to be determined every 12 hours (SR 3.4.4.1).
The 30 day Completion Time of Required Action A.1 is acceptable, basedon operating experience, considering the multiple forms of leakagedetection that are still available.
(continued)
SUSQUEHANNA  
SUSQUEHANNA  
-UNIT 1TS / B 3.4-32Revision 2
-UNIT 1 TS / B 3.4-32 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES ACTIONS B.1 and B.2 (continued)
PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6BASESACTIONS B.1 and B.2(continued)
With both gaseous and particulate primary containment atmospheric monitoring channels inoperable, grab samples of the primary containment atmosphere must be taken and analyzed to provide periodic leakage information.
With both gaseous and particulate primary containment atmospheric monitoring channels inoperable, grab samples of the primary containment atmosphere must be taken and analyzed to provide periodic leakageinformation.
Provided a sample is obtained and analyzed once every 12 hours, the plant may be operated for up to 30 days to allow restoration of at least one of the required monitors.The 12 hour interval provides periodic information that is adequate to detect LEAKAGE. The 30 day Completion Time for restoration recognizes that at least one other form of leakage detection is available.
Provided a sample is obtained and analyzed once every12 hours, the plant may be operated for up to 30 days to allow restoration of at least one of the required monitors.
C.1 and C.2 and C.3 With the drywell floor drain sump monitoring system inoperable, the only means of detecting LEAKAGE is the primary containment atmospheric gaseous radiation monitor. A Note clarifies this applicability of the Condition.
The 12 hour interval provides periodic information that is adequate todetect LEAKAGE.
The primary containment atmospheric gaseous radiation monitor typically cannot detect a 1 gpm leak within one hour when RCS activity is low. In addition, this configuration does not provide the required diverse means of leakage detection.
The 30 day Completion Time for restoration recognizes that at least one other form of leakage detection is available.
Indirect methods of monitoring RCS leakage must be implemented.
C.1 and C.2 and C.3With the drywell floor drain sump monitoring system inoperable, the onlymeans of detecting LEAKAGE is the primary containment atmospheric gaseous radiation monitor.
Grab samples of the primary containment atmosphere must be taken and analyzed and monitoring of RCS leakage by administrative means must be performed every 12 hours to provide alternate periodic information.
A Note clarifies this applicability of theCondition.
Administrative means of monitoring RCS leakage include monitoring and trending parameters that may indicate an increase in RCS leakage. There are diverse alternative mechanisms from which appropriate indicators may be selected based on plant conditions.
The primary containment atmospheric gaseous radiation monitor typically cannot detect a 1 gpm leak within one hour when RCSactivity is low. In addition, this configuration does not provide the requireddiverse means of leakage detection.
It is not necessary to utilize all of these methods, but a method or methods should be selected considering the current plant conditions and historical or expected sources of unidentified leakage. The administrative methods are primary containment pressure, temperature, Component Cooling Water System outlet temperatures and makeup, Reactor Recirculation System pump seal pressure and temperature and motor cooler temperature indications, Drywell cooling fan outlet temperatures, Reactor Building Chiller amperage, Control Rod Drive System flange temperatures, Safety Relief Valve tailpipe temperature, flow, pressure, or other approved methods.These indications, coupled with the atmospheric grab samples, are sufficient to alert the operating staff to an unexpected increase in unidentified LEAKAGE.(continued)
Indirect methods of monitoring RCSleakage must be implemented.
Grab samples of the primary containment atmosphere must be taken and analyzed and monitoring of RCS leakageby administrative means must be performed every 12 hours to providealternate periodic information.
Administrative means of monitoring RCS leakage include monitoring andtrending parameters that may indicate an increase in RCS leakage.
Thereare diverse alternative mechanisms from which appropriate indicators maybe selected based on plant conditions.
It is not necessary to utilize all ofthese methods, but a method or methods should be selected considering the current plant conditions and historical or expected sources ofunidentified leakage.
The administrative methods are primarycontainment
: pressure, temperature, Component Cooling Water Systemoutlet temperatures and makeup, Reactor Recirculation System pumpseal pressure and temperature and motor cooler temperature indications, Drywell cooling fan outlet temperatures, Reactor Building Chilleramperage, Control Rod Drive System flange temperatures, Safety ReliefValve tailpipe temperature, flow, pressure, or other approved methods.These indications, coupled with the atmospheric grab samples, aresufficient to alert the operating staff to an unexpected increase inunidentified LEAKAGE.(continued)
SUSQUEHANNA  
SUSQUEHANNA  
-UNIT ITS / B 3.4-33Revision 2
-UNIT I TS / B 3.4-33 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES ACTIONS C.1, C.2 and C.3 (continued)
PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6BASESACTIONS C.1, C.2 and C.3 (continued)
The 12 hour interval is sufficient to detect increasing RCS leakage. The Required Action provides 7 days to restore another RCS leakage monitor to OPERABLE status to regain the intended leakage detection diversity.
The 12 hour interval is sufficient to detect increasing RCS leakage.
The 7 day Completion Time ensures that the plant will not be operated in a degraded configuration for a lengthy time period.D.1 and D.2 If any Required Action of Condition A, B or C cannot be met within the associated Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours and MODE 4 within 36 hours.The allowed Completion Times are reasonable, based on operating experience, to perform the actions in an orderly manner and without challenging plant systems.E. 1 With all required monitors inoperable, no required automatic means of monitoring LEAKAGE are available, and immediate plant shutdown in accordance with LCO 3.0.3 is required.SURVEILLANCE SR 3.4.6.1 REQUIREMENTS This SR is for the performance of a CHANNEL CHECK of the required primary containment atmospheric monitoring system. The check gives reasonable confidence that the channel is operating properly.
TheRequired Action provides 7 days to restore another RCS leakage monitorto OPERABLE status to regain the intended leakage detection diversity.
The Frequency of 12 hours is based on instrument reliability and is reasonable for detecting off normal conditions.
The 7 day Completion Time ensures that the plant will not be operated ina degraded configuration for a lengthy time period.D.1 and D.2If any Required Action of Condition A, B or C cannot be met within theassociated Completion Time, the plant must be brought to a MODE inwhich the LCO does not apply. To achieve this status, the plant must bebrought to at least MODE 3 within 12 hours and MODE 4 within 36 hours.The allowed Completion Times are reasonable, based on operating experience, to perform the actions in an orderly manner and withoutchallenging plant systems.E. 1With all required monitors inoperable, no required automatic means ofmonitoring LEAKAGE are available, and immediate plant shutdown inaccordance with LCO 3.0.3 is required.
SR 3.4.6.2 This SR is for the performance of a CHANNEL FUNCTIONAL TEST of the required RCS leakage detection instrumentation.
SURVEILLANCE SR 3.4.6.1REQUIREMENTS This SR is for the performance of a CHANNEL CHECK of the requiredprimary containment atmospheric monitoring system. The check givesreasonable confidence that the channel is operating properly.
The test ensures that the monitors can perform their function in the desired manner. The Frequency of 31 days considers instrument reliability, and operating experience has shown it proper for detecting degradation.(continued)
TheFrequency of 12 hours is based on instrument reliability and is reasonable for detecting off normal conditions.
SR 3.4.6.2This SR is for the performance of a CHANNEL FUNCTIONAL TEST of therequired RCS leakage detection instrumentation.
The test ensures thatthe monitors can perform their function in the desired manner. TheFrequency of 31 days considers instrument reliability, and operating experience has shown it proper for detecting degradation.
(continued)
SUSQUEHANNA  
SUSQUEHANNA  
-UNIT 1TS / B 3.4-34Revision 1
-UNIT 1 TS / B 3.4-34 Revision 1 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES SURVEILLANCE REQUIREMENTS (continued)
PPL Rev. 4RCS Leakage Detection Instrumentation B 3.4.6BASESSURVEILLANCE REQUIREMENTS (continued)
This SR is for the performance of a CHANNEL CALIBRATION of required leakage detection instrumentation channels.
This SR is for the performance of a CHANNEL CALIBRATION of requiredleakage detection instrumentation channels.
The calibration verifies the accuracy of the instrument string, including the instruments located inside containment.
The calibration verifies theaccuracy of the instrument string, including the instruments located insidecontainment.
The Frequency of 24 months is a typical refueling cycle and considers channel reliability.
The Frequency of 24 months is a typical refueling cycle andconsiders channel reliability.
REFERENCES  
REFERENCES  
: 1. 10 CFR 50, Appendix A, GDC 30.2. Regulatory Guide 1.45, Revision 0, "Reactor Coolant PressureBoundary Leakage Detection Systems,"
: 1. 10 CFR 50, Appendix A, GDC 30.2. Regulatory Guide 1.45, Revision 0, "Reactor Coolant Pressure Boundary Leakage Detection Systems," May 1973.3. GEAP-5620, April 1968.4. NUREG-75/067, October 1975.5. FSAR Section 5.2.5.4.6. FSAR, Section 5.2.5.1.2.
May 1973.3. GEAP-5620, April 1968.4. NUREG-75/067, October 1975.5. FSAR Section 5.2.5.4.6. FSAR, Section 5.2.5.1.2.
: 7. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).SUSQUEHANNA  
: 7. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).SUSQUEHANNA  
-UNIT ITS / B 3.4-34aRevision 0}}
-UNIT I TS / B 3.4-34a Revision 0}}

Revision as of 22:53, 9 July 2018

Susquehanna, Unit 1, Revision to Technical Specifications Bases Manual
ML14063A429
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 02/20/2014
From: Gerlach R M
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
2014-6725
Download: ML14063A429 (26)


Text

Feb. 20, 2014 Page 1 of 2 MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2014-6725 USER INFORMATION:

GERLACH*ROSEY M EMPL#:028401 CA#: 0363 Address: NUCSA2 Phone#: 254-3194 TRANSMITTAL INFORMATION:

TO: GERLACH*ROSEY M LOCATION:

USNRC 02/20/2014 FROM: NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU. HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE.UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL. TOOLS FROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF ERRORS.ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.TSB1 -TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL REMOVE MANUAL TABLE OF CONTENTS DATE: 12/10/2013 ADD MANUAL TABLE OF CONTENTS DATE: 02/19/2014 CATEGORY:

DOCUMENTS TYPE: TSBI Feb. 20, 2014 Page 2 of 2 ID: TEXT 3.4.6 REMOVE: REV:3 ADD: REV: 4 CATEGORY:

DOCUMENTS TYPE: TSB1 ID: TEXT LOES ADD: REV: 113 REMOVE: REV:112 ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS @ X3107 OR X3136 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL Table Of Contents'Issue Date: 02/19/2014 Procedure Name Rev TEXT LOES 113 Title: LIST OF EFFECTIVE SECTIONS CO N T OLLPD Issue Date 02/19/2014 Change ID Change Number TEXT TOC Title: TABLE OF CONTENTS 22 03/28/2013 TEXT 2.1.1 5 Title: SAFETY LIMITS (SLS) REACTOR TEXT 2.1.2 1 Title: SAFETY LIMITS (SLS) REACTOR 05/06/2009 CORE SLS 10/04/2007 COOLANT SYSTEM (RCS) PRESSURE S TEXT 3.0 3 08/20/2009 Title: LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY TEXT 3.1.1 Title: REACTIVITY TEXT 3.1.2 Title: REACTIVITY TEXT 3.1.3 Title: REACTIVITY TEXT 3.1.4 Title: REACTIVITY TEXT 3.1.5 Title: REACTIVITY TEXT 3.1.6 Title: REACTIVITY 1 04/18/2006 CONTROL SYSTEMS SHUTDOWN MARGIN (SDM)0 11/15/2002 CONTROL SYSTEMS REACTIVITY ANOMALIES 2 CONTROL SYSTEMS 4 CONTROL SYSTEMS 1 CONTROL SYSTEMS 2 CONTROL SYSTEMS 01/19/2009 CONTROL ROD OPERABILITY 01/30/2009 CONTROL ROD SCRAM TIMES 07/06/2005 CONTROL ROD SCRAM ACCUMULATORS 04/18/2006 ROD PATTERN CONTROL Page 1 of 8 Report Date: 02/20/14 Page I of 8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 4 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.1.7 3 04/23/2008 Title: REACTIVITY CONTROL SYSTEMS STANDBY LIQUID CONTROL (SLC) SYSTEM TEXT 3.1.8 3 05/06/2009 Title: REACTIVITY CONTROL SYSTEMS SCRAM DISCHARGE VOLUME (SDV) VENT AND DRAIN VALVES TEXT 3.2.1 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS AVERAGE PLANAR LINEAR HEAT GENERATION RATE (APLHGR)TEXT 3.2.2 3 05/06/2009 Title: POWER DISTRIBUTION LIMITS MINIMUM CRITICAL POWER RATIO (MCPR)TEXT 3.2.3 2 04/23/2008 Title: POWER DISTRIBUTION LIMITS LINEAR HEAT GENERATION RATE (LHGR)TEXT 3.3.1.1 5 07/23/2013 Title: INSTRUMENTATION REACTOR PROTECTION SYSTEM (RPS) INSTRUMENTATION TEXT 3.3.1.2 2 01/19/2009 Title: INSTRUMENTATION SOURCE RANGE MONITOR (SRM) INSTRUMENTATION TEXT 3.3.2.1 3 04/23/2008 Title: INSTRUMENTATION CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.3.2.2 2 04/05/2010 Title: INSTRUMENTATION FEEDWATER MAIN TURBINE HIGH WATER LEVEL TRIP INSTRUMENTATION TEXT 3.3.3.1 9 02/28/2013 Title: INSTRUMENTATION POST ACCIDENT MONITORING (PAM) INSTRUMENTATION TEXT 3.3.3.2 1 04/18/2005 Title: INSTRUMENTATION REMOTE SHUTDOWN SYSTEM TEXT 3.3.4.1 Title: INSTRUMENTATION 1 04/23/2008 END OF CYCLE RECIRCULATION PUMP TRIP (EOC-RPT)

INSTRUMENTATIO W Pager of 8 Report Date: 02/20/14 Page 2 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.3.4.2 0 11/15/2002 Title: INSTRUMENTATION ANTICIPATED TRANSIENT WITHOUT SCRAM RECIRCULATION PUMP TRIP (ATWS-RPT)

INSTRUMENTATION TEXT 3.3.5.1 Title: INSTRUMENTATION TEXT 3.3.5.2 Title: INSTRUMENTATION 3 08/20/2009 EMERGENCY CORE COOLING SYSTEM (ECCS) INSTRUMENTATION 0 11/15/2002 REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM INSTRUMENTATION TEXT 3.3.6.1 5 07/23/2013 Title: INSTRUMENTATION PRIMARY CONTAINMENT ISOLATION INSTRUMENTATION TEXT 3.3.6.2 Title: INSTRUMENTATION TEXT 3.3.7.1 Title: INSTRUMENTATION INSTRUMENTATION TEXT 3.3.8.1 Title: INSTRUMENTATION TEXT 3.3.8.2 Title: INSTRUMENTATION TEXT 3.4.1 Title: REACTOR COOLANT 4 09/01/2010 SECONDARY CONTAINMENT ISOLATION INSTRUMENTATION 2 10/27/2008 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM 2 12/17/2007 LOSS OF POWER (LOP) INSTRUMENTATION 0 11/15/2002 REACTOR PROTECTION SYSTEM (RPS) ELECTRIC POWER MONITORING 4 04/27/2010 SYSTEM (RCS) RECIRCULATION LOOPS OPERATING TEXT 3.4.2 3 10/23/2013 Title: REACTOR COOLANT SYSTEM (RCS) JET PUMPS TEXT 3. 4.3 Title: REACTOR COOLANT TEXT 3.4.4 Title: REACTOR COOLANT 3 01/13/2012 SYSTEM RCS SAFETY RELIEF VALVES S/RVS 0 11/15/2002 SYSTEM (RCS) RCS OPERATIONAL LEAKAGE Page3 of 8 Report Date: 02/20/14 Page 3 of 8 Report Date: 02/20/14 SSES M4A.NUAL Manual Name: TSBI Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.4.5 1 01/16/2006 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE ISOLATION VALVE (PIV) LEAKAGE TEXT 3.4.6 4 02/19/2014 Title: REACTOR COOLANT SYSTEM (RCS) RCS LEAKAGE DETECTION INSTRUMENTATION TEXT 3.4.7 2 10/04/2007 Title: REACTOR COOLANT SYSTEM (RCS) RCS SPECIFIC ACTIVITY TEXT 3.4.8 Title: REACTOR COOLANT-HOT SHUTDOWN TEXT 3.4.9 Title: REACTOR COOLANT-COLD SHUTDOWN 2 SYSTEM (RCS)1 SYSTEM (RCS)03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING SYSTEM 03/28/2013 RESIDUAL HEAT REMOVAL (RHR) SHUTDOWN COOLING SYSTEM 0 TEXT 3.4.10 3 04/23/2008 Title: REACTOR COOLANT SYSTEM (RCS) RCS PRESSURE AND TEMPERATURE (P/T) LIMITS TEXT 3.4.11 0 11/15/2002 Title: REACTOR COOLANT SYSTEM (RCS) REACTOR STEAM DOME PRESSURE TEXT 3.5.1 2 01/16/2006 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM ECCS -OPERATING TEXT 3.5.2 0 11/15/2002 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM ECCS -SHUTDOWN TEXT 3.5.3 2 07/09/2010 Title: EMERGENCY CORE COOLING SYSTEMS (ECCS) AND REACTOR SYSTEM RCIC SYSTEM CORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)CORE ISOLATION COOLING (RCIC)TEXT 3.6.1.1 Title: PRIMARY CONTAINMENT 4 11/09/2011 TEXT 3.6.1.2 1 04/23/2008 Title: CONTAINMENT SYSTEMS PRIMARY CONTAINMENT AIR LOCK Page4 of 8 Report Date: 02/20/14 Page 4 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSBl Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.1.3 Title: CONTAINMENT TEXT 3.6.1.4 Title: CONTAINMENT TEXT 3.6.1.5 Title: CONTAINMENT TEXT 3.6.1.6 Title: CONTAINMENT TEXT 3.6.2.1 Title: CONTAINMENT TEXT 3.6.2.2 Title: CONTAINMENT TEXT 3.6.2.3 Title: CONTAINMENT TEXT 3.6.2.4 Title: CONTAINMENT TEXT 3.6.3.1 Title: CONTAINMENT TEXT 3.6.3.2 Title: CONTAINMENT TEXT 3.6.3.3 Title: CONTAINMENT TEXT 3.6.4.1 Title: CONTAINMENT 10 05/23/2012 SYSTEMS PRIMARY CONTAINMENT ISOLATION VALVES (PCIVS)1 04/23/2008 SYSTEMS CONTAINMENT PRESSURE 1 10/05/2005 SYSTEMS DRYWELL AIR TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKERS 2 04/23/2008 SYSTEMS SUPPRESSION POOL AVERAGE TEMPERATURE 0 11/15/2002 SYSTEMS SUPPRESSION POOL WATER LEVEL 1 01/16/2006 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL COOLING 0 11/15/2002 SYSTEMS RESIDUAL HEAT REMOVAL (RHR) SUPPRESSION POOL SPRAY 2 06/13/2006 SYSTEMS PRIMARY CONTAINMENT HYDROGEN RECOMBINERS 1 04/18/2005 SYSTEMS DRYWELL AIR FLOW SYSTEM 1 02/28/2013 SYSTEMS PRIMARY CONTAINMENT OXYGEN CONCENTRATION 9 12/10/2013 SYSTEMS SECONDARY CONTAINMENT Page 5 of 8 Report Date: 02/20/14 Page 5 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.6.4.2 8 03/28/2013 Title: CONTAINMENT SYSTEMS SECONDARY CONTAINMENT ISOLATION VALVES (SCIVS)TEXT 3.6.4.3 4 09/21/2006 Title: CONTAINMENT SYSTEMS STANDBY GAS TREATMENT (SGT) SYSTEM TEXT 3.7.1 4 04/05/2010 Title: PLANT SYSTEMS RESIDUAL HEAT REMOVAL SERVICE WATER (RHRSW) SYSTEM AND THE ULTIMATE HEAT SINK (UHS)TEXT 3.7.2 Title: PLANT 2 02/11/2009 SYSTEMS EMERGENCY SERVICE WATER (ESW) SYSTEM TEXT 3.7.3 Title: PLANT SYSTEMS 1 01/08/2010 CONTROL ROOM EMERGENCY OUTSIDE AIR SUPPLY (CREOAS) SYSTEM TEXT 3.7.4 Title: PLANT TEXT 3.7.5 Title: PLANT TEXT 3.7.6 Title: PLANT TEXT 3.7.7 Title: PLANT 0 11/15/2002 SYSTEMS CONTROL ROOM FLOOR COOLING SYSTEM 1 10/04/2007 SYSTEMS MAIN CONDENSER OFFGAS 2 04/23/2008 SYSTEMS MAIN TURBINE BYPASS SYSTEM 1 10/04/2007 SYSTEMS SPENT FUEL STORAGE POOL WATER LEVEL TEXT 3.7.8 Title: PLANT SYSTEMS 0 04/23/2008 TEXT 3.8.1 6 05/06/2009 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -OPERATING TEXT 3.8.2 0 11/15/2002 Title: ELECTRICAL POWER SYSTEMS AC SOURCES -SHUTDOWN Page~ of 8 Report Date: 02/20/14 Page 6 of .8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.8.3 Title: ELECTRICAL TEXT 3.8.4 Title: ELECTRICAL TEXT 3.8.5 Title: ELECTRICAL TEXT 3.8.6 Title: ELECTRICAL TEXT 3.8.7 Title: ELECTRICAL TEXT 3.8.8 Title: ELECTRICAL TEXT 3.9.1 Title: REFUELING TEXT 3.9.2 Title: REFUELING TEXT 3.9.3 Title: REFUELING C TEXT 3.9.4 Title: REFUELING C TEXT 3.9.5 Title: REFUELING C TEXT 3.9.6 Title: REFUELING C 4 10/23/2013 POWER SYSTEMS DIESEL FUEL OIL, LUBE OIL, AND STARTING AIR 3 01/19/2009 POWER SYSTEMS DC SOURCES -OPERATING 1 12/14/2006 POWER SYSTEMS DC SOURCES -SHUTDOWN POWER SYST POWER SYST POWER SYST)PERATIONS)PERATIONS)PERATIONS)PERATIONS)PERATIONS)PERATIONS 1 12/14/2006

'EMS BATTERY CELL PARAMETERS 1 10/05/2005

'EMS DISTRIBUTION SYSTEMS -OPERATING 0 11/15/2002 PEMS DISTRIBUTION SYSTEMS -SHUTDOWN 0 11/15/2002 REFUELING EQUIPMENT INTERLOCKS 1 09/01/2010 REFUEL POSITION ONE-ROD-OUT INTERLOCK 0 11/15/2002 CONTROL ROD POSITION 0 11/15/2002 CONTROL ROD POSITION INDICATION 0 11/15/2002 CONTROL ROD OPERABILITY

-REFUELING 1 10/04/2007 REACTOR PRESSURE VESSEL (RPV) WATER LEVEL Page7 of 8 Report Date: 02/20/14 Page 7 of 8 Report Date: 02/20/14 SSES MANUAL Manual Name: TSB1 Manual Title: TECHNICAL SPECIFICATION BASES UNIT 1 MANUAL TEXT 3.9.7 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -HIGH WATER LEVEL TEXT 3.9.8 0 11/15/2002 Title: REFUELING OPERATIONS RESIDUAL HEAT REMOVAL (RHR) -LOW WATER LEVEL TEXT 3.10.1 Title: SPECIAL TEXT 3.10.2 Title: SPECIAL TEXT 3.10.3 Title: SPECIAL TEXT 3.10.4 Title: SPECIAL TEXT 3.10.5 Title: SPECIAL TEXT 3.10.6 Title: SPECIAL TEXT 3.10.7 Title: SPECIAL TEXT 3.10.8 Title: SPECIAL OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS OPERATIONS 1 01/23/2008 INSERVICE LEAK AND HYDROSTATIC TESTING OPERATION 0 11/15/2002 REACTOR MODE SWITCH INTERLOCK TESTING 0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL

-HOT SHUTDOWN 0 11/15/2002 SINGLE CONTROL ROD WITHDRAWAL

-COLD SHUTDOWN 0 11/15/2002 SINGLE CONTROL ROD DRIVE (CRD) REMOVAL -REFUELING 0 11/15/2002 MULTIPLE CONTROL ROD WITHDRAWAL

-REFUELING 1 04/18/2006 CONTROL ROD TESTING -OPERATING 1 04/12/2006 SHUTDOWN MARGIN (SDM) TEST -REFUELING Page~ of 8 Report Date: 02/20/14 Page 8 of .8 Report Date: 02/20/14 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision TOC Table of Contents 22 B 2.0 SAFETY LIMITS BASES Page B 2.0-1 0 Page TS / B 2.0-2 3 Page TS / B 2.0-3 5 Page TS / B 2.0-4 3 Page TS / B 2.0-5 5 Page TS / B 2.0-6 1 Pages TS / B 2.0-7 through TS / B 2.0-9 1 B 3.0 LCO AND SR APPLICABILITY BASES Page TS / B 3.0-1 1 Pages TS I B 3.0-2 through TS / B 3.0-4 0 Pages TS / B 3.0-5 through TS / B 3.0-7 1 Page TS / B 3.0-8 3 Pages TS / B 3.0-9 through TS / B 3.0-11 2 Page TS / B 3.0-1 Ia 0 Page TS / B 3.0-12 1 Pages TS / B 3.0-13 through TS / B 3.0-15 2 Pages TS / B 3.0-16 and TS / B 3.0-17 0 B 3.1 REACTIVITY CONTROL BASES Pages B 3.1-1 through B 3.1-4 0 Page TS / B 3.1-5 1 Pages TS / B 3.1-6 and TS / B 3.1-7 2 Pages B 3.1-8 through B 3.1-13 0 Page TS / B 3.1-14 1 Page B 3.1-15 0 Page TS / B 3.1-16 1 Pages B 3.1-17 through B 3.1-19 0 Pages TS / B 3.1-20 and TS / B 3.1-21 1 Page TS / B 3.1-22 0 Page TS / B 3.1-23 1 Page TS / B 3.1-24 0 Pages TS / B 3.1-25 through TS / B 3.1-27 1 Page TS / B 3.1-28 2 Page TS / B 3.1-29 1 Pages B 3.1-30 through B 3.1-33 0 Pages TS / B 3.3-34 through TS / B 3.3-36 1 Pages TS / B 3.1-37 and TS / B 3.1-38 2 Pages TS / B 3.1-39 and TS / B 3.1-40 2 Page TS / B 3.1-40a 0 Pages TS / B 3.1-41 and TS / B 3.1-42 2 SUSQUEHANNA

-UNIT 1 TS I B LOES-1 Revision 113 SUSQUEHANNA

-UNIT 1 TS / B LOES-1 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.1.43 1 Page TS / B 3.1-44 0 Page TS / B 3.1-45 3 Pages TS / B 3.1-46 t hrough TS / B 3.1-49 1 Page TS / B 3.1-50 0 Page TS / B 3.1-51 3 B 3.2 POWER DISTRIBUTION LIMITS BASES Page TS / B 3.2-1 2 Pages TS / B 3.2-2 and TS / B 3.2-3 3 Pages TS / B 3.2-4 and TS / B 3.2-5 2 Page TS / B 3.2-6 3 Page B 3.2-7 1 Pages TS / B 3.2-8 and TS / B 3.2-9 3 Page TS / B 3.2.10 2 Page TS / B 3.2-11 3 Page TS / B 3.2-12 1 Page TS / B 3.2-13 2 B 3.3 INSTRUMENTATION Pages TS / B 3.3-1 through TS / B 3.3-4 1 Page TS / B 3.3-5 2 Page TS / B 3.3-6 1 Page TS / B 3.3-7 3 Page TS / B 3.3-7a 1 Page TS / B 3.3-8 5 Pages TS / B 3.3-9 through TS / B 3.3-12 3 Pages TS / B 3.3-12a 1 Pages TS / B 3.3-12b and TS / B 3.3-12c 0 Page TS / B 3.3-13 1 Page TS / B 3.3-14 3 Pages TS / B 3.3-15 and TS / B 3.3-16 1 Pages TS / B 3.3-17 and TS / B 3.3-18 4 Page TS / B 3.3-19 1 Pages TS / B 3.3-20 through TS / B 3.3-22 2 Page TS / B 3.3-22a 0 Pages TS / B 3.3-23 and TS / B 3.3-24 2 Pages TS / B 3.3-24a and TS / B 3.3-24b 0 Page TS / B 3.3-25 3 Page TS / B 3.3-26 2 Page TS / B 3.3-27 1 Pages TS / B 3.3-28 through TS / B 3.3-30 3 Page TS / B 3.3-30a 0 SUSQUEHANNA

-UNIT 1 TS I B LOES-2 Revision 113 SUSQUEHANNA

-UNIT 1 TS / B LOES-2 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.3-31 4 Page TS / B 3.3-32 5 Pages TS / B 3.3-32a 0 Page TS / B 3.3-32b 1 Page TS / B 3.3-33 5 Page TS / B 3.3-33a 0 Page TS / B 3.3-34 1 Pages TS / B 3.3-35 and TS / B 3.3-36 2 Pages TS / B 3.3-37 and TS / B 3.3-38 1 Page TS / B 3.3-39 2 Pages TS / B 3.3-40 through TS / B 3.3-43 1 Page TS / B 3.3-44 4 Pages TS / B 3.3-44a and TS / B 3.3-44b 0 Page TS / B 3.3-45 3 Pages TS / B 3.3-45a and TS / B 3.3-45b 0 Page TS / B 3.3-46 3 Pages TS / B 3.3-47 2 Pages TS / B 3.3-48 through TS / B 3.3-51 3 Pages TS / B 3.3-52 and TS / B 3.3-53 2 Page TS / B 3-3-53a 0 Page TS / B 3.3-54 4 Page TS / B 3.3-55 2 Pages TS / B 3.3-56 and TS / B 3.3-57 1 Page TS / B 3.3-58 0 Page TS / B 3.3-59 1 Page TS / B 3.3-60 0 Page TS / B 3.3-61 1 Pages TS / B 3.3-62 and TS / B 3.3-63 0 Pages TS / B 3.3-64 and TS / B 3.3-65 2 Page TS / B 3.3-66 4 Page TS / B 3.3-67 3 Page TS / B 3.3-68 4 Page TS / B 3.3-69 5 Pages TS / B 3.3-70 4 Page TS / B 3.3-71 3 Pages TS / B 3.3-72 and TS / B 3.3-73 2 Page TS / B 3.3-74 3 Page TS / B 3.3-75 2 Page TS / B 3.3-75a 6 Page TS / B 3.3-75b 7 Page TS / B 3.3-75c 6 SUSQUEHANNA

-UNIT I TS/BLOES-3 Revision 113 SUSQUEHANNA

-UNIT 1 TS / B LOES-3 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages B 3.3-76 through 3.3-77 0 Page TS / B 3.3-78 1 Pages B 3.3-79 through B 3.3-81 0 Page B 3.3-82 1 Page B 3.3-83 0 Pages B '3.3-84 and B 3.3-85 1 Page B 3.3-86 0 Page B 3.3-87 1 Page B 3.3-88 0 Page B 3.3-89 1 Page TS / B 3.3-90 1 Page B 3.3-91 0 Pages TS / B 3.3-92 through TS / B 3.3-100 1 Pages TS / B 3.3-101 through TS / B 3.3-103 0 Page TS / B 3.3-104 2 Pages TS / B 3.3-105 and TS / B 3.3-106 0 Page TS / B 3.3-107 1 Page TS I B 3.3-108 0 Page TS / B 3.3-109 1 Pages TS / B 3.3-110 and TS/B 3.3-111 0 Pages TS / B 3.3-112 and TS / B 3.3-112a 1 Pages TS / B 3.3-113 through TS / B 3.3-115 1 Page TS / B 3.3-116 3 Page TS / B 3.3-117 1 Pages TS / B 3.3-118 through TS / B 3.3-122 0 Pages TS / B 3.3-123 and TS / B 3.3-124 1 Page TS / B 3.3-124a 0 Page TS / B 3.3-125 0 Pages TS / B 3.3-126 and TS / B 3.3-127 1 Pages TS I B 3.3-128 through TS/ B 3.3-130 0 Page TS / B 3.3-131 1 Pages TS / B 3.3-132 through TS / B 3.3-134 0 Pages B 3.3-135 through B 3.3-137 0 Page TS / B 3.3-138 1 Pages B 3.3-139 through B 3.3-149 0 Pages TS / B 3.3-150 and TS / B 3.3-151 1 Pages TS / B 3.3-152 through TS / B 3.3-154 2 Page TS / B 3.3-155 1 Pages TS / B 3.3-156 through TS / B 3.3-158 2 Pages TS / B 3.3-159 through TS / B 3.3-162 1 Page TS / B 3.3-163 2 Page TS / B 3.3-164 1 Pages TS / B 3.3-165 through TS / B 3.3-167 2 SUSQUEHANNA-UNITI TSIBLOES-4 Revision 113 SUSQUEHANNA

-UNIT 1 0 TS / B LOES-4 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages TS / B 3.3-168 and TS / B 3.3-169 1 Page TS / B 3.3-170 2 Pages TS / B 3.3-171 through TS / B 3.3-177 1 Pages TS / B 3.3-178 through TS / B 3.3-179a 2 Pages TS / B 3.3-179b and TS / B 3.3-179c 0 Page TS / B 3.3-180 1 Page TS / B 3.3-181 3 Page TS / B 3.3-182 1 Page TS / B 3.3-183 2 Page TS / B 3.3-184 1 Page TS / B 3.3-185 4 Page TS / B 3.3-186 1 Pages TS / B 3.3-187 and TS / B 3.3-188 2 Pages TS / B 3.3-189 through TS / B 3.3-191 1 Page TS / B 3.3-192 0 Page TS / B 3.3-193 1 Pages TS / B 3.3-194 and TS / B 3.3-195 0 Page TS / B 3.3-196 2 Pages TS / B 3.3-197 through TS / B 3.3-204 0 Page TS / B 3.3-205 1 Pages B 3.3-206 through B 3.3-209 0 Page TS / B 3.3-210 1 Pages B 3.3-211 through B 3.3-219 0 B 3.4 REACTOR COOLANT SYSTEM BASES Pages B 3.4-1 and B 3.4-2 0 Pages TS / B 3.4-3 and Page TS / B 3.4-4 4 Page TS / B 3.4-5 3 Pages TS / B 3.4-6 through TS / B 3.4-9 2 Page TS / B 3.4-10 1 Pages TS / 3.4-11 and TS / B 3.4-12 0 Page TS / B 3.4-13 2 Page TS / B 3.4-14 1 Page TS / B 3.4-15 2 Pages TS / B 3.4-16 and TS / B 3.4-17 4 Page TS / B 3.4-18 2 Pages B 3.4-19 through B 3.4-27 0 Pages TS / B 3.4-28 and TS / B 3.4-29 1 Page TS / B 3.4-30 2 Page TS / B 3.4-31 1 Pages TS / B 3.4-32 and TS / B 3.4-33 2 Page TS / B 3.4-34 1 Page TS / B 3.4-34a 0 Pages TS / B 3.4-35 and TS / B 3.4-36 1 SUSQUEHANNA

-UNIT I TSIBLOES-5 Revision 113 SUSQUEHANNA

-UNIT 1 TS / B LOES-5 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.4-37 2 Page TS / B 3.4-38 1 Pages B 3.4-39 and B 3.4-40 0 Page TS / B 3.4-41 2 Pages TS / B 3.4-42 through TS / B 3.4-45 0 Page TS / B 3.4-46 1 Pages TS B 3.4-47 and TS / B 3.4-48 0 Page TS / B 3.4-49 3 Page TS / B 3.4-50 1 Page TS / B 3.4-51 3 Page TS / B 3.4-52 2 Page TS / B 3.4-53 1 Pages TS / B 3.4-54 through TS / B 3.4-56 2 Page TS / B 3.4-57 3 Pages TS / B 3.4-58 through TS / B 3.4-60 1 B 3.5 ECCS AND RCIC BASES Pages B 3.5-1 and B 3.5-2 0 Page TS / B 3.5-3 2 Page TS / B 3.5-4 1 Page TS / B 3.5-5 2 Page TS / B 3.5-6 1 Pages B 3.5-7 through B 3.5-10 0 Page TS / B 3.5-11 1 Page TS / B 3.5-12 0 Page TS / B 3.5-13 1 Pages TS / B 3.5-14 and TS / B 3.5-15 0 Pages TS / B 3.5-16 through TS / B 3.5-18 1 Pages B 3.5-19 through B 3.5-24 0 Page TS / B 3.5-25 through TS / B 3.5-27 1 Page TS / B 3.5-28 0 Page TS I B 3.5-29 1 Pages TS / B 3.5-30 and TS / B 3.5-31 0 B 3.6 CONTAINMENT SYSTEMS BASES Page TS / B 3.6-1 2 Page TS / B 3.6-1a 3 Page TS / B 3.6-2 4 Page TS / B 3.6-3 3 Page TS / B 3.6-4 4 Pages TS / B 3.6-5 and TS I B 3.6-6 3 Page TS / B 3.6-6a 2 Page TS / B 3.6-6b 3 Page TS / B 3.6-6c 0 Page B 3.6-7 0 SUSQUEHANNA

-UNIT 1 TS/BLOES-6 Revision 113 SUSQUEHANNA

-UNIT 1 TS / B LOES-6 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page B 3.6-8 1 Pages B 3.6-9 through B 3.6-14 0 Page TS / B 3.6-15 3 Page TS / B 3.6-15a 0 Page TS / B 3.6-15b 2 Pages TS / B 3.6-16 and TS / B 3.6-17 2 Page TS J B 3.6-17a I 1 Pages TS / B 3.6-18 and TS / B 3.6-19 0 Page TS / B 3.6-20 1 Page TS / B 3.6-21 2 Page TS I B 3.6-22 1 Page TS / B 3.6-22a 0 Page TS / B 3.6-23 1 Pages TS / B 3.6-24 and TS / B 3.6-25 0 Pages TS / B 3.6-26 and TS / B 3.6-27 2 Page TS / B 3.6-28 7 Page TS / B 3.6-29 2 Page TS / B 3.6-30 1 Page TS / B 3.6-31 3 Pages TS / B 3.6-32 and TS / B 3.6-33 1 Pages TS / B 3.6-34 and TS / B 3.6-35 0 Page TS / B 3.6-36 1 Page TS / B 3.6-37 0 Page TS / B 3.6-38 3 Page TS / B 3.6-39 2 Page TS / B 3.6-40 6 Page TS / B 3.6-40a 0 Page B 3.6-41 1 Pages B 3.6-42 and B 3.6-43 3 Pages TS / B 3.6-44 and TS / B 3.6-45 1 Page TS / B 3.6-46 2 Pages TS / B 3.6-47 through TS / B 3.6-51 1 Page TS / B 3.6-52 2 Pages TS / B 3.6-53 through TS / B 3.6-56 0 Page TS / B 3.6-57 1 Page TS / 3.6-58 2 Pages B 3.6-59 through B 3.6-63 0 Pages TS / B 3.6-64 and TS / B 3.6-65 1 Pages B 3.6-66 through B 3.6-69 0 Pages TS / B 3.6-70 through TS / B 3.6-72 1 Page TS / B 3.6-73 2 Pages TS / B 3.6-74 and TS / B 3.6-75 1 Pages B 3.6-76 and B 3.6-77 0 SUSQUEHANNA

-UNIT 1 TS / B LOES-7 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Page TS / B 3.6-78 1 Pages B 3.6-79 and B 3.3.6-80 0 Page TS / B 3.6-81 1 Pages TS / B 3.6-82 and TS / B 3.6-83 0 Page TS / B 3.6-84 4 Page TS / B 3.6-85 2 Page TS / B 3.6-86 4 Pages TS / B 3.6-87 through TS / B 3.6-88a 2 Page TS / B 3.6-89 5 Page TS / B 3.6-90 3 Page TS [ B 3.6-90a 0 Pages TS / B 3.6-91 and TS / B 3.6-92 3 Page TS / B 3.6-93 2 Pages TS / B 3.6-94 through TS / B 3.6-96 1 Page TS / B 3.6-97 2 Page TS / 8 3.6-98 1 Page TS / B 3.6-99 2 Pages TS / B 3.6-100 and TS / B 3.6-100a 5 Page TS / B 3.6-100b 3 Pages TS / B 3.6-101 and TS / B 3.6-102 1 Pages TS / B 3.6-103 and TS / B 3.6-104 2 Page TS / B 3.6-105 3 Page TS / B 3.6-106 2 Page TS / B 3.6-107 3 B 3.7 PLANT SYSTEMS BASES Pages TS / B 3.7-1 3 Page TS /B 3.7-2 4 Pages TS / B 3.7-3 through TS / B 3.7-5 3 Page TS / B 3.7-5a I Page TS / B 3.7-6 3 Page TS / B 3.7-6a 2 Page TS / B 3.7-6b 1 Page TS / B 3.7-6c 2 Page TS / B 3.7-7 3 Page TS / B 3.7-8 2 Pages TS / B 3.7-9 through TS / B 3.7-11 1 Pages TS / B 3.7-12 and TS / B 3.7-13 2 Pages TS / B 3.7-14 through TS / B 3.7-18 3 Page TS / B 3.7-18a 1 Pages TS I B 3.7-18b through TS / B 3.7-18e 0 Pages TS / B 3.7-19 through TS / B 3.7-23 1 Page TS / B 3.7-24 1 SUSQUEHANNA

-UNIT 1 TS / B LOES-8 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision Pages TS / B 3.7-25 and TS / B 3.7-26 0 Pages TS / B 3.7-27 through TS / B 3.7-29 5 Page TS / B 3.7-30 2 Page TS / B 3.7-31 1 Page TS / B 3.7-32 0 Page TS / B 3.7-33 1 Pages TS / B 3.7-34 through TS / B 3.7-37 0 B 3.8 ELECTRICAL POWER SYSTEMS BASES Page TS / B 3.8-1 3 Pages TS / B 3.8-2 and TS / B 3.8-3 2 Page TS / B 3.8-4 3 Pages TS / B 3.8-4a and TS / B 3.8-4b 0 Page TS / B 3.8-5 5 Page TS / B 3.8-6 3 Pages TS / B 3.8-7 through TS/B 3.8-8 2 Page TS / B 3.8-9 4 Page TS / B 3.8-10 3 Pages TS / B 3.8-11 and TS / B 3.8-17 2 Page TS / B 3.8-18 3 Pages TS / B 3.8-19 through TS / B 3.8-21 2 Pages TS / B 3.8-22 and TS / B 3.8-23 3 Pages TS / B 3.8-24 through TS / B 3.8-37 2 Pages B 3.8-38 through B 3.8-44 0 Page TS / B 3.8-45 3 Pages TS / B 3.8-46 through TS / B 3.8-48 0 Pages TS / B 3.8-49 and TS / B 3.8-50 3 Page TS / B 3.8-51 1 Page TS / B 3.8-52 0 Page TS / B 3.8-53 1 Pages TS / B 3.8-54 through TS / B 3.8-57 2 Pages TS / B 3.8-58 through TS / B 3.8-61 3 Pages TS / B 3.8-62 and TS / B 3.8-63 5 Page TS / B 3.8-64 4 Page TS / B 3.8-65 5 Pages TS / B 3.8-66 through TS / B 3.8-77 1 Pages TS / B 3.8-77A through TS / B 3.8-77C 0 Pages B 3.8-78 through B 3.8-80 0 Page TS / B 3.8-81 1 Pages B 3.8-82 through B 3.8-90 0 SUSQUEHANNA

-UNIT 1 TSIB LOES-9 Revision 113.SUSQUEHANNA

-UNIT 1 TS I B LOES-9 Revision 113 SUSQUEHANNA STEAM ELECTRIC STATION LIST OF EFFECTIVE SECTIONS (TECHNICAL SPECIFICATIONS BASES)Section Title Revision B 3.9 REFUELING OPERATIONS BASES Pages TS / B 3.9-1 and TS / B 3.9-1a I Pages TS / B 3.9-2 through TS / B 3.9-5 1 Pages TS / B 3.9-6 through TS / B 3.9-8 0 Pages B 3.9-9 through B 3.9-18 0 Pages TS / B 3.9-19 through TS / B 3.9-21 1 Pages B 3.9-22 through B 3.9-30 0 B 3.10 SPECIAL OPERATIONS BASES Page TS / B 3.10-1 2 Pages TS / B 3.10-2 through TS I B 3.10-5 1 Pages B 3.10-6 through B 3.10-31 0 Page TS / B 3.10-32 2 Page B 3.10-33 0 Page TS / B 3.10-34 1 Pages B 3.10-35 and B 3.10-36 0 Page TS / B 3.10-37 1 Page TS / B 3.10-38 2 TSB1 Text LOES.doc 2/11/2014 SUSQUEHANNA

-UNIT 1 TS / B LOES-10 Revision 113 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 B 3.4 REACTOR COOLANT SYSTEM (RCS)B 3.4.6 RCS Leakage Detection Instrumentation BASES BACKGROUND GDC 30 of 10 CFR 50, Appendix A (Ref. 1), requires means for detecting and, to the extent practical, identifying the location of the source of RCS LEAKAGE. Regulatory Guide 1.45, Revision 0, (Ref. 2) describes acceptable methods for selecting leakage detection systems.Limits on LEAKAGE from the reactor coolant pressure boundary (RCPB)are required so that appropriate action can be taken before the integrity of the RCPB is impaired (Ref. 2). Leakage detection systems for the RCS are provided to alert the operators when leakage rates above normal background levels are detected and also to supply quantitative measurement of leakage rates. The Bases for LCO 3.4.4, "RCS Operational LEAKAGE," discuss the limits on RCS LEAKAGE rates.Systems for separating the LEAKAGE of an identified source from an unidentified source are necessary to provide prompt and quantitative information to the operators to permit them to take immediate corrective action.LEAKAGE from the RCPB inside the drywell is detected by at least one of two or three independently monitored variables, such as sump level changes and drywell gaseous and particulate radioactivity levels. The primary means of quantifying LEAKAGE in the drywell is the drywell floor drain sump monitoring system which consists of two drywell floor drain sump level Channels.

Both Channels are required to be Operable to satisfy the LCO.The drywell floor drain sump monitoring system monitors the LEAKAGE collected in the floor drain sump. This unidentified LEAKAGE consists of LEAKAGE from control rod drives, valve flanges or packings, floor drains, the Closed Cooling Water System, and drywell air cooling unit condensate drains, and any LEAKAGE not collected in the drywell equipment drain tank.The level of each drywell sump is continuously recorded in the Main Control Room. The change in (continued)

SUSQUEHANNA

-UNIT 1 TS I B 3.4-30 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES BACKGROUND (continued) sump level per unit time determines the leak rate and is calculated from the recorder.The floor drain sump level indicators have switches that start and stop the sump pumps when required.

If the sump fills to the high high level setpoint, an alarm sounds in the control room.The primary containment air monitoring systems continuously monitor the primary containment atmosphere for airborne particulate and gaseous radioactivity.

A sudden increase of radioactivity, which may be attributed to RCPB steam or reactor water LEAKAGE, is annunciated in the control room.APPLICABLE SAFETY ANALYSES A threat of significant compromise to the RCPB exists if the barrier contains a crack that is large enough to propagate rapidly. LEAKAGE rate limits are set low enough to detect the LEAKAGE emitted from a single crack in the RCPB (Refs. 3 and 4). The allowed LEAKAGE rates are well below the rates predicted for critical crack sizes (Ref. 5).Therefore, these limits provide adequate response before a significant break in the RCPB can occur.RCS leakage detection instrumentation satisfies Criterion 1 of the NRC Policy Statement (Ref. 7).LCO This LCO requires instruments of diverse monitoring principles to be OPERABLE to provide confidence that small amounts of unidentified-LEAKAGE are detected in time to allow actions to place the plant in a safe condition, when RCS LEAKAGE indicates possible RCPB degradation.

The LCO requires two instruments to be OPERABLE.The drywell floor drain sump monitoring system is required to quantify the unidentified LEAKAGE rate from the RCS. Thus, for the system to be considered OPERABLE, the sump level monitoring portion of the system must be OPERABLE and capable of determining the leakage rate. The identification of an increase in unidentified LEAKAGE will be delayed by the time required for the unidentified LEAKAGE to travel to the drywell floor drain sump and it may take longer than one hour to detect a 1 gpm increase in unidentified LEAKAGE, depending on the origin and magnitude of the LEAKAGE. This sensitivity is acceptable for primary containment sump monitor OPERABILITY.(continued)

SUSQUEHANNA

-UNIT 1 TS / B 3.4-31 Revision 1 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES LCO (continued)

The reactor coolant contains radioactivity that, when released to the primary containment, can be detected by the gaseous or particulate primary containment atmospheric radioactivity monitor. Only one of the two detectors is required to be OPERABLE.

Radioactivity detection systems are included for monitoring both particulate and gaseous activities because of their sensitivities and rapid responses to RCS LEAKAGE, but have recognized limitations.

Reactor coolant radioactivity levels will be low during initial reactor startup and for a few weeks thereafter, until activated corrosion products have been formed and fission products appear from fuel element cladding contamination or cladding defects. If there are few fuel element cladding defects and low levels of activation products, it may not be possible for the gaseous or particulate primary containment atmospheric radioactivity monitors to detect a 1 gpm increase within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> during normal operation.

However, the gaseous or particulate containment primary atmospheric radioactivity monitor is OPERABLE when it is capable of detecting a 1 gpm increase in unidentified LEAKAGE within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> given an RCS activity equivalent to that assumed in the design calculations for the monitors (Reference 6).The LCO is satisfied when monitors of diverse measurement means are available.

Thus, the drywell floor drain sump monitoring system, in combination with a gaseous or particulate primary containment atmospheric radioactivity monitor provides an acceptable minimum.APPLICABILITY In MODES 1, 2, and 3, leakage detection systems are required to be OPERABLE to support LCO 3.4.4. This Applicability is consistent with that for LCO 3.4.4.ACTIONS A.1 With the drywell floor drain sump monitoring system inoperable, the primary containment atmospheric activity monitor will provide indication of changes in leakage.With the drywell floor drain sump monitoring system inoperable, operation may continue for 30 days. However, RCS unidentified and total LEAKAGE is still required to be determined every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> (SR 3.4.4.1).The 30 day Completion Time of Required Action A.1 is acceptable, based on operating experience, considering the multiple forms of leakage detection that are still available.(continued)

SUSQUEHANNA

-UNIT 1 TS / B 3.4-32 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES ACTIONS B.1 and B.2 (continued)

With both gaseous and particulate primary containment atmospheric monitoring channels inoperable, grab samples of the primary containment atmosphere must be taken and analyzed to provide periodic leakage information.

Provided a sample is obtained and analyzed once every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, the plant may be operated for up to 30 days to allow restoration of at least one of the required monitors.The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> interval provides periodic information that is adequate to detect LEAKAGE. The 30 day Completion Time for restoration recognizes that at least one other form of leakage detection is available.

C.1 and C.2 and C.3 With the drywell floor drain sump monitoring system inoperable, the only means of detecting LEAKAGE is the primary containment atmospheric gaseous radiation monitor. A Note clarifies this applicability of the Condition.

The primary containment atmospheric gaseous radiation monitor typically cannot detect a 1 gpm leak within one hour when RCS activity is low. In addition, this configuration does not provide the required diverse means of leakage detection.

Indirect methods of monitoring RCS leakage must be implemented.

Grab samples of the primary containment atmosphere must be taken and analyzed and monitoring of RCS leakage by administrative means must be performed every 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> to provide alternate periodic information.

Administrative means of monitoring RCS leakage include monitoring and trending parameters that may indicate an increase in RCS leakage. There are diverse alternative mechanisms from which appropriate indicators may be selected based on plant conditions.

It is not necessary to utilize all of these methods, but a method or methods should be selected considering the current plant conditions and historical or expected sources of unidentified leakage. The administrative methods are primary containment pressure, temperature, Component Cooling Water System outlet temperatures and makeup, Reactor Recirculation System pump seal pressure and temperature and motor cooler temperature indications, Drywell cooling fan outlet temperatures, Reactor Building Chiller amperage, Control Rod Drive System flange temperatures, Safety Relief Valve tailpipe temperature, flow, pressure, or other approved methods.These indications, coupled with the atmospheric grab samples, are sufficient to alert the operating staff to an unexpected increase in unidentified LEAKAGE.(continued)

SUSQUEHANNA

-UNIT I TS / B 3.4-33 Revision 2 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES ACTIONS C.1, C.2 and C.3 (continued)

The 12 hour1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> interval is sufficient to detect increasing RCS leakage. The Required Action provides 7 days to restore another RCS leakage monitor to OPERABLE status to regain the intended leakage detection diversity.

The 7 day Completion Time ensures that the plant will not be operated in a degraded configuration for a lengthy time period.D.1 and D.2 If any Required Action of Condition A, B or C cannot be met within the associated Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.The allowed Completion Times are reasonable, based on operating experience, to perform the actions in an orderly manner and without challenging plant systems.E. 1 With all required monitors inoperable, no required automatic means of monitoring LEAKAGE are available, and immediate plant shutdown in accordance with LCO 3.0.3 is required.SURVEILLANCE SR 3.4.6.1 REQUIREMENTS This SR is for the performance of a CHANNEL CHECK of the required primary containment atmospheric monitoring system. The check gives reasonable confidence that the channel is operating properly.

The Frequency of 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> is based on instrument reliability and is reasonable for detecting off normal conditions.

SR 3.4.6.2 This SR is for the performance of a CHANNEL FUNCTIONAL TEST of the required RCS leakage detection instrumentation.

The test ensures that the monitors can perform their function in the desired manner. The Frequency of 31 days considers instrument reliability, and operating experience has shown it proper for detecting degradation.(continued)

SUSQUEHANNA

-UNIT 1 TS / B 3.4-34 Revision 1 PPL Rev. 4 RCS Leakage Detection Instrumentation B 3.4.6 BASES SURVEILLANCE REQUIREMENTS (continued)

This SR is for the performance of a CHANNEL CALIBRATION of required leakage detection instrumentation channels.

The calibration verifies the accuracy of the instrument string, including the instruments located inside containment.

The Frequency of 24 months is a typical refueling cycle and considers channel reliability.

REFERENCES

1. 10 CFR 50, Appendix A, GDC 30.2. Regulatory Guide 1.45, Revision 0, "Reactor Coolant Pressure Boundary Leakage Detection Systems," May 1973.3. GEAP-5620, April 1968.4. NUREG-75/067, October 1975.5. FSAR Section 5.2.5.4.6. FSAR, Section 5.2.5.1.2.
7. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).SUSQUEHANNA

-UNIT I TS / B 3.4-34a Revision 0