Enclosure 4 of PLA-7625 Marked-Up Technical Specification Bases Pages Revised Technical Specifications Bases Pages Unit 1 TS Bases Pages TOC-1, TOC-2, 3.3-108, 3.3-110, 3.3-112, 3.3-113, 3.3-11 5, 3.3-124a, 3.3-126, 3.3-134A, 3.3-134B, 3.3-134C, 3.3-134D, 3.3-134E, 3.3-134F, 3.3-134G, 3.3-134H, 3.3-1341, 3.3-135, 3.3-136, 3.3-137, 3.3-138, 3.3-139, 3.3-140, 3.3-141, 3.3-142, 3.3-143, 3.3-144, 3.3-145, 3.3-146, 3.3-169, 3.3-170, 3.3-176, 3.3-183, 3.3-185, 3.3-186, 3.3-194, 3.3-196, 3.3-197, 3.5-1, 3.5-6, 3.5-19, 3.5-20, 3.5-21, 3.5-22, 3.5-23, 3.5-24, 3.5-25, 3.5-26, 3.5-30, 3.6-16, 3.6-l 7a, 3.6-18, 3.6-22a, 3.6-23, 3.6-26, 3.6-28, 3.6-29, 3.6-60, 3.6-86, 3.6-87, 3.6-93, 3.6-96, 3.6-97, 3.6-103, 3.6-104, 3.6-105, 3.6-106, 3.7-16, 3.7-18A, 3.7-18B, 3.7-20, 3.7-21, 3.7-22, 3.7-23, 3.8-38, 3.8-40, 3.8-41, 3.8-42, 3.8-43, 3.8-66, 3.8-67, 3.8-68, 3.8-86, 3.8-87, 3.8-88, 3.8-89, and 3.10-3 Unit 2 TS Bases Pages TOC-1, TOC-2, 3.3-108, 3.3-110, 3.3-112, 3.3-113, 3.3-116, 3.3-124a, 3.3-126, 3.3-134A, 3.3-134B, 3.3-134C, 3.3-134D, 3.3-134E, 3.3-134F, 3.3-134G, 3.3-134H, 3.3-1341, 3.3-135, 3.3-136, 3.3-137, 3.3-138, 3.3-139, 3.3-140, 3.3-141, 3.3-142, 3.3-143, 3.3-144, 3.3-145, 3.3-146, 3.3-168, 3.3-1 69, 3.3-175, 3.3-183, 3.3-185, 3.3-186, 3.3-194, 3.3-196, 3.3-197, 3.5-1, 3.5-6, 3.5-19, 3.5-20, 3.5-21, 3.5-22, 3.5-23, 3.5-24, 3.5-25, 3.5-26, 3.5-30, 3.6-16, 3.6-17a, 3.6-18, 3.6-22, 3.6-23, 3.3-26, 3.3-28, 3.3-29, 3.6-59, 3.6-85, 3.6-86, 3.6-92, 3.6-95, 3.6-96, 3.6-102, 3.6-103, 3.6-104, 3.6-105, 3.7-16, 3.7-18A, 3.7-18B, 3.7-20, 3.7-21, 3.7-22, 3.7-23, 3.8-39, 3.8-41, 3.8-42, 3.8-43, 3.8-44, 3.8-70, 3.8-71, 3.8-72, 3.8-74, 3.8-94, 3.8-95, 3.8-96, 3.8-97, 3.8-98, and 3.10-3
TABLE OF CONTENTS (TECHNICAL SPECIFICATIONS BASES)
B2.0 B2.1.1 B2.1.2 B3.0 B3.1 B3.1.1 B3.1.2 B3.1.3 B3.1.4 B3.1.5 B3.1.6 B3.1.7 B3.1.8 B3.2 B3.2.1 B3.2.2 B3.2.3 B3.3 B3.3.1.1 B3.3.1.2 B3.3.2.1 B3.3.2.2 B3.3.3.1 B3.3.3.2 B3.3.4.1 B3.3.4.2 B3.3.5.1 B3.3.5.2 B3. 3. 5.~~
B3.3.6.1 B3.3.6.2 B3.3.7.1 SAFETY LIMITS (SLs)............................................................................. TS/B2.0-1 Reactor Core SLs...................................................................... TS/B2.0-1 Reactor Coolant System (RCS) Pressure SL............................ TS/B2.0-7 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY........ TS/B3.0-1 REACTIVITY CONTROL SYSTEMS..................................................... B3.1-1 Shutdown Margin (SOM)................................................................. B3.1-1 Reactivity Anomalies....................................................................... B3.1-8 Control Rod OPERABILITY............................................................. B3.1-13 Control Rod Scram Times......................................................... TS/B3.1-22 Control Rod Scram Accumulators............................................. TS/B3.1-29 Rod Pattern Control................................................................... TS/B3.1-34 Standby Liquid Control (SLC) System....................................... TS/B3.1-39 Scram Discharge Volume (SDV) Vent and Drain Valves.......... TS/B3.1-47 POWER DISTRIBUTION LIMITS.................................................... TS/B3.2-1 Average Planar Linear Heat Generation Rate (APLHGR)......... TS/B3.2-1 Minimum Critical Power Ratio (MCPR)...................................... TS/B3.2-5 Linear Heat Generation Rate (LHGR)....................................... TS/B3.2-10 INSTRUMENTATION...................................................................... TS/B3.3-1 Reactor Protection System (RPS) Instrumentation................... TS/B3.3-1 Source Range Monitor (SRM) Instrumentation.......................... TS/B3.3-35 Control Rod Block Instrumentation............................................ TS/B3.3-44 Feedwater - Main Turbine High Water Level Trip Instrumentation.................................................................... TS/B3.3-55 Post Accident Monitoring (PAM) Instrumentation...................... TS/B3.3-64 Remote Shutdown System.............................................................. B3.3-76 End of Cycle Recirculation Pump Trip (EOC-RPT)
Instrumentation.......................................................................... B3.3-81 Anticipated Transient Without Scram Recirculation Pump Trip (A TWS-RPT) Instrumentation.............................. TS/B3.3-92 Emergency Core Cooling System (ECCS)
Instrumentation.................................................................... TS/B3.3-101 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation....................................................................... B3.3-134A Reactor Core Isolation Cooling (RCIC) System Instrumentation.......................................................................... B3.3-135 Primary Containment Isolation Instrumentation......................... TS/B3.3-147 Secondary Containment Isolation Instrumentation.................... TS/B3.3-180 Control Room Emergency Outside Air Supply (CREOAS)
System Instrumentation....................................................... TS/B3.3-192 (continued)
SUSQUEHANNA - UNIT 1 B TOC - 1 Revision~
TABLE OF CONTENTS (TECHNICAL SPECIFICATIONS BASES)
B3.3 B3.3.8.1 B3.3.8.2 B3.4 B3.4.1 B3.4.2 B3.4.3 B3.4.4 B3.4.5 B3.4.6 B3.4.7 B3.4.8 B3.4.9 B3.4.10 B3.4.11 B3.5 B3.5.1 B3.5.2 B3.5.3 B3.6 B3.6.1.1 B3.6.1.2 B3.6.1.3 B3.6.1.4 B3.6.1.5 B3.6.1.6 B3.6.2.1 B3.6.2.2 B3.6.2.3 B3.6.2.4 B3.6.3.1 B3.6.3.2 B3.6.3.3 B3.6.4.1 B3.6.4.2 B3.6.4.3 INSTRUMENTATION (continued)
Loss of Power (LOP) Instrumentation....................................... TS/B3.3-205 Reactor Protection System (RPS) Electric Power Monitoring.................................................................................. B3.3-213 REACTOR COOLANT SYSTEM (RCS)............................................ TS/B3.4-1 Recirculation Loops Operating.................................................... TS/B3.4-1 Jet Pumps.................................................................................. TS/B3.4-10 Safety/Relief Valves (S/RVs)..................................................... TS/B3.4-15 RCS Operational LEAKAGE........................................................... B3.4-19 RCS Pressure Isolation Valve (PIV) Leakage................................. B3.4-24 RCS Leakage Detection Instrumentation.................................. TS/B3.4-30 RCS Specific Activity................................................................. TS/B3.4-35 Residual Heat Removal (RHR) Shutdown Cooling System - Hot Shutdown............................................................ B3.4-39 Residual Heat Removal (RHR) Shutdown Cooling System - Cold Shutdown.................................................... TS/B3.4-44 RCS Pressure and Temperature (PIT) Limits............................ TS/B3.4-49 Reactor Steam Dome Pressure................................................. TS/B3.4-58 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM.................................. B3.5-1 ECCS - Operating........................................................................... B3.5-1 EGGS ShutdovmReactor Pressure Vessel (RPV) Water Inventory Control B3.5-19 RCIC System............................................................................. TS/B3.5-25 CONTAINMENT SYSTEMS............................................................ TS/B3.6-1 Primary Containment................................................................. TS/B3.6-1 Primary Containment Air Lock......................................................... B3.6-7 Primary Containment Isolation Valves (PCIVs)......................... TS/B3.6-15 Containment Pressure..................................................................... B3.6-41 Drywell Air Temperature............................................................ TS/B3.6-44 Suppression Chamber-to-Drywell Vacuum Breakers................ TS/B3.6-47 Suppression Pool Average Temperature.................................. TS/B3.6-53 Suppression Pool Water Level........................................................ B3.6-59 Residual Heat Removal (RHR) Suppression Pool Cooling....................................................................................... B3.6-62 Residual Heat Removal (RHR) Suppression Pool Spray................ B3.6-66 Not Used.................................................................................... TS/B3.6-70 Drywell Air Flow System.................................................................. B3.6-76 Primary Containment Oxygen Concentration............................ TS/B3.6-81 Secondary Containment............................................................ TS/B3.6-84 Secondary Containment Isolation Valves (SC IVs).................... TS/B3.6-91 Standby Gas Treatment (SGT) System.................................... TS/B3.6-101 (continued)
SUSQUEHANNA - UNIT 1 B TOC - 2 Revision~
BASES (continued)
APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 The actions of the ECCS are explicitly assumed in the safety analyses of References 1 and 2. The ECCS is initiated to preserve the integrity of the fuel cladding by limiting the post LOCA peak cladding temperature to less than the 10 CFR 50.46 limits.
ECCS instrumentation satisfies Criterion 3 of the NRC Policy Statement (Ref.
4). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
The OPERABILITY of the ECCS instrumentation is dependent upon the OPERABILITY of the individual instrumentation and channel Functions specified in Table 3.3.5.1-1. Each Function must have a required number of OPERABLE channels, with their setpoints within the specified Allowable Values, where appropriate. The actual setpoint is calibrated consistent with applicable setpoint methodology assumptions. Each ECCS subsystem must also respond within its assumed response time. Table 3.3.5.1-1,
footnotes (b.§) and (GQ), are added to show that certain ECCS instrumentation Functions are also required to be OPERABLE to perform DG initiation and actuation of other Technical Specifications (TS) function.
Allowable Values are specified for each ECCS Function specified in the table. Nominal trip setpoints are specified in the setpoint calculations. The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS. Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. Trip setpoints are those predetermined values of output at which an action should take place. The setpoints are compared to the actual process parameter (e.g., reactor vessel water level), and when the measured output value of the process parameter reaches the setpoint, the associated device changes state. The analytic limits are derived from the limiting values of the process parameters obtained from the safety analysis. The Allowable Values are derived from the analytic limits, corrected for calibration, process, and some of the instrument errors.
The trip setpoints are then determined, accounting for the remaining instrument errors (e.g., drift). The trip setpoints derived in this manner (continued)
SUSQUEHANNA - UNIT 1 TS/B3.3-108 Revision G
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 1.a, 2.a. Reactor Vessel Water Level-Low Low Low, Level 1 (continued)
Reactor Vessel Water Level-Low Low Low, Level 1 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-Low Low Low, Level 1 Allowable Value is chosen to allow time for the low pressure core flooding systems to activate and provide adequate cooling The initiation logic for LPCI pumps and injection valves is cross connected such that either division's start signal will start all four pumps and open both loop's injection valves. This cross division logic is required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the initiation circuitry is not required. Therefore, in MODES 4 and 5 for LPCI, only one division of initiation logic is required.
DGs C and D which are initiated from the LPCI LOCA initiation are cross connected such that both DGs receive an initiation signal from both Divisions of the LPCI LOCA initiation circuitry. This cross connected logic is only required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the DG initiation circuitry is not required. Therefore, in MODES 4 and 5 for DGs C and D only one division of EGGS initiation logic is required.
Four channels of Reactor Vessel Water Level-Low Low Low, Level 1 Function are only required to be OPERABLE when the ECCS or DG(s) are required to be OPERABLE to ensure that no single instrument failure can preclude ECCS and DG initiation. Refer to LCO 3.5.1 and LCO 3.5.2, "EGGS Shutdown," for Applicability Bases for the low pressure EGGS subsystems; LCO 3.8.1, "AC Sources Operating"; and LCO 3.8.2, "AC Sources Shutdown," for Applicability Bases for the DGs.
1.b, 2.b. Drywell Pressure-High High pressure in the drywell could indicate a break in the reactor coolant pressure boundary (RCPB). The low pressure ECCS (provided a concurrent low reactor pressure signal is (continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-110 Revision tl
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 1.c, 1.d, 2.c, 2.d Reactor Steam Dome Pressure-Low (continued)
(Ref. 1 ). The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 1 O CFR 50.46.
The Reactor Steam Dome Pressure-Low signals are initiated from four pressure instruments that sense the reactor dome pressure.
The pressure instruments are set to actuate between the Upper and Lower Allowable Values on decreasing reactor dome pressure.
The Upper Allowable Value is low enough to ensure that the reactor dome pressure has fallen to a value below the Core Spray and RHR/LPCI maximum design pressures to preclude piping overpressurization.
The Lower Allowable Value is high enough to ensure that the ECCS injection prevents the fuel peak cladding temperature from exceeding the limits of 10 CFR 50.46.
DGs C and D which are initiated from the LPCI LOCA initiation are cross connected such that both DGs receive an initiation signal from both Divisions of the LPCI LOCA initiation circuitry. This cross connected logic is only required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the DG initiation circuitry is not required. Therefore, in MODES 4 and 5 for DGs C and D only one division of ECCS initiation logic is required.
Four channels of Reactor Steam Dome Pressure-Low Function are required to be OPERABLE only when the ECCS is required to be OPERABLE to ensure that no single instrument failure can preclude ECCS initiation. Refer to LGO 3.5.1 and LGO 3.5.2 for Applicability Bases for the low pressure EGGS subsystems.
1.e, 2.f. Manual Initiation The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to provide manual initiation capability and are redundant to the automatic protective instrumentation. There is one push button for each of the CS and LPCI subsystems (i.e., two for CS and two for LPCI).
The Manual Initiation Function is not assumed in any accident or transient analyses in the FSAR. However, the Function is (continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-112 Revision 4-
I l
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY 1.e, 2.f. Manual Initiation (continued)
ECCS Instrumentation B 3.3.5.1 There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
Each channel of the Manual Initiation Function (one channel per subsystem) is required to be OPERABLE only when the associated ECCS is required to be OPERABLE. Refer to LGO 3.5.1 and LGO 3.5.2 f-Or Applicability Bases f-Or the low pressure EGGS subsystems.
2.e. Reactor Steam Dome Pressure-Low (Recirculation Discharge Valve Permissive)
Low reactor steam dome pressure signals are used as permissives for recirculation discharge and bypass valves closure. This ensures that the LPCI subsystems inject into the proper RPV location assumed in the safety analysis. The Reactor Steam Dome Pressure-Low is one of the Functions assumed to be OPERABLE and capable of closing the valves during the transients analyzed in Reference 2. The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46. The Reactor Steam Dome Pressure-Low Function is directly assumed in the analysis of the recirculation line break (Ref. 1 ).
The Reactor Steam Dome Pressure-Low signals are initiated from four pressure instruments that sense the reactor dome pressure.
The Allowable Value is chosen to ensure that the valves close prior to commencement of LPCI injection flow into the core, as assumed in the safety analysis.
Four channels of the Reactor Steam Dome Pressure-Low Function are only required to be OPERABLE in MODES 1, 2, and 3 with the associated recirculation pump discharge valve open. With the valve(s) closed, the function instrumentation has been performed; thus, the Function is not required. In MODES 4 and 5, the loop injection location is not critical since LPCI injection through the recirculation loop in either direction will still ensure that LPCI flow reaches the core (i.e., there is no significant reactor steam dome back pressure).
(continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-113 Revision-+
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY 3.b. Drvwell Pressure-High (continued)
ECCS Instrumentation B 3.3.5.1 RPS, ensures that the fuel peak cladding temperature remains below the limits of 1 O CFR 50.46.
High drywell pressure signals are initiated from four pressure instruments that sense drywell pressure. The Allowable Value was selected to be as low as possible to be indicative of a LOCA inside primary containment.
Four channels of the Drywell Pressure-High Function are required to be OPERABLE when HPCI is required to be OPERABLE to ensure that no single instrument failure can preclude HPCI initiation. Refer to LCO 3.5.1 for the Applicability Bases for the HPCI System.
3.c. Reactor Vessel Water Level-High, Level 8 High RPV water level indicates that sufficient cooling water inventory exists in the reactor vessel such that there is no danger to the fuel. Therefore, the Level 8 signal is used to trip the HPCI turbine to prevent overflow into the main steam lines (MSLs). The Reactor Vessel Water Level-High, Level 8 Function is not assumed in the accident and transient analyses. It was retained since it is a potentially significant contributor to risk.
Reactor Vessel Water Level-High, Level 8 signals for HPCI are initiated from two level instruments. Both Level 8 signals are required in order to trip HPCI. This ensures that no single instrument failure can preclude an HPCI initiation or trip. The Reactor Vessel Water Level-High, Level 8 Allowable Value is chosen to prevent flow from the HPCI System from overflowing into the MSLs.
Two channels of Reactor Vessel Water Level-High, Level 8 Function are required to be OPERABLE only when HPCI is required to be OPERABLE.
Refer to LCO 3.5.1 and LCO 3.5.2 for HPCI Applicability Bases.
3.d. Condensate Storage Tank Level-Low The Condensate Storage Tank-Low signal indicates that a conservatively calculated NPSH-available limit is being approached.
(continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-115 Revision-+
BASES ACTIONS 8.1, 8.2, and B.3 (continued)
ECCS Instrumentation B 3.3.5.1 channels must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. As noted (Note 1 to Required Action B.1 ), Required Action B.1 is only applicable in MODES 1, 2, and 3. In MODES 4 and 5, the specific initiation time of the loi.\\' pressure EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of initiation capability for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (as allowed by Required Action B.3) is allowed during MODES 4 and 5. There is no similar Note provided for Required Action B.2 since HPGI instrumentation is not required in MODES 4 and 5; thus, a Note is not necessary. Notes are also provided (the Note--2 to Required Action B.1 and the Note to Required Action 8.2) to delineate which Required Action is applicable for each Function that requires entry into Condition B if an associated channel is inoperable. This ensures that the proper loss of initiation capability check is performed.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action B.1, the Completion Time only begins upon discovery that a redundant feature in both Divisions (e.g., both CS subsystems) cannot be automatically (continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-124a Revision G
BASES ECCS Instrumentation B 3.3.5.1 ACTIONS C.1 and C.2 (continued) capability), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Action C.2 is not appropriate and the feature(s) associated with the inoperable channels must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Since each inoperable channel would have Required Action C.1 applied separately (refer to ACTIONS Note), each inoperable channel would only require the affected portion of the associated system to be declared inoperable.
However, since channels for both low pressure ECCS subsystems are inoperable (e.g., both CS subsystems), and the Completion Times started concurrently for the channels in both subsystems, this results in the affected portions in both subsystems being concurrently declared inoperable. For Functions 1.d, 2.d, and 2.e, the affected portions are the associated low pressure ECCS pumps. As noted (Note 1),
Required Action G.1 is only applicable in MODES 1, 2, and 3. In MODES 4 and 5, the specific initiation time of the EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of automatic initiation capability for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (as allowed by Required Action G.2) is allowed during MODES 4 and 5.
The Note--2 states that Required Action C.1 is only applicable for Functions 1.d, 2.d, and 2.e. Required Action C.1 is not applicable to Functions 1.e, 2.f, and 3.e (which also require entry into this Condition if a channel in these Functions is inoperable),
since they are the Manual Initiation Functions and are not assumed in any accident or transient analysis. Thus, a total loss of manual initiation capability for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (as allowed by Required Action C.2) is allowed. Required Action C.1 is also not applicable to Function 3.c (which also requires entry into this Condition if a channel in this Function is inoperable), since the loss of one channel results in a loss of the Function (two-out-of-two logic). This loss was considered during the development of Reference 3 and considered acceptable for the 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed by Required Action C.2.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action C.1, the Completion Time only begins upon discovery that the same feature in both subsystems (e.g., both CS subsystems) cannot be automatically initiated (continued)
SUSQUEHANNA - UNIT 1 TS I B 3.3-126 Revision Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 B 3.3 INSTRUMENTATION B 3.3.5.2 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation BASES BACKGROUND The RPV contains penetrations below the top of the active fuel (T AF) that have the potential to drain the reactor coolant inventory to below the TAF.
If the water level should drop below the TAF, the ability to remove decay heat is reduced, which could lead to elevated cladding temperatures and clad perforation. Safety Limit 2.1.1.3 requires the RPV water level to be above the top of the active irradiated fuel at all times to prevent such elevated cladding temperatures.
Technical Specifications are required by 1 O CFR 50.36 to include limiting safety system settings (LSSS) for variables that have significant safety functions. LSSS are defined by the regulation as "Where a LSSS is specified for a variable on which a safety limit has been placed. the setting must be chosen so that automatic protective actions will correct the abnormal situation before a Safety Limit (SL) is exceeded." The Analytical Limit is the limit of the process variable at which a safety action is initiated to ensure that a SL is not exceeded. Any automatic protection action that occurs on reaching the Analytical Limit therefore ensures that the SL is not exceeded. However. in practice. the actual settings for automatic protection channels must be chosen to be more conservative than the Analytical Limit to account for instrument loop uncertainties related to the setting at which the automatic protective action would actually occur. The actual settings for the automatic isolation channels are the same as those established for the same functions in MODES 1, 2, and 3 in LCO 3.3.5.1, "Emergency Core Cooling System (ECCS)
Instrumentation," or LCO 3.3.6.1, "Primary Containment Isolation Instrumentation".
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses.
RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur. Under the definition of DRAIN TIME. some penetration flow paths may be excluded from the DRAIN TIME calculation if they will be isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the T AF when actuated by RPV water level isolation instrumentation.
SUSQUEHANNA - UNIT 1 B 3.3-134A
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.
5.2 BACKGROUND
(continued)
APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY The purpose of the RPV Water Inventory Control Instrumentation is to support the requirements of LCO 3.5.2, "Reactor Pressure Vessel (RPV)
Water Inventory Control," and the definition of DRAIN TIME. There are functions that are required for manual initiation or operation of the ECCS injection/spray subsystem required to be OPERABLE by LCO 3.5.2 and other functions that support automatic isolation of Residual Heat Removal subsystem and Reactor Water Cleanup system penetration flow path(s) on low RPV water level.
The RPV Water Inventory Control Instrumentation supports operation of core spray (CS) and low pressure coolant injection (LPCI). The equipment involved with each of these systems is described in the Bases for LCO 3.5.2.
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses. RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure.
reduced piping stresses. and ductile piping systems. Instead. an event is postulated in which a single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate. or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g.,
seismic event, loss of normal power. single human error). It is assumed, based on engineering judgment, that while in MODES 4 and 5. one low pressure ECCS injection/spray subsystem can be manually initiated to maintain adequate reactor vessel water level.
As discussed in References 1. 2. 3. 4. and 5. operating experience has shown RPV water inventory to be significant to public health and safety.
Therefore. RPV Water Inventory Control satisfies Criterion 4 of 1 O CFR 50.36( c)(2)(ii).
Permissive and interlock setpoints are generally considered as nominal values without regard to measurement accuracy.
The specific Applicable Safety Analyses. LCO. and Applicability discussions are listed below on a Function by Function basis.
SUSQUEHANNA - UNIT 1 B 3.3-134B
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
Core Spray and Low Pressure Coolant Injection Systems 1.a, 2.a. Reactor Steam Dome Pressure - Low (Injection Permissive)
Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. This function ensures that. prior to opening the injection valves of the low pressure ECCS subsystems, the reactor pressure has fallen to a value below these subsystems' maximum design pressure. While it is assured during MODES 4 and 5 that the reactor steam dome pressure will be below the ECCS maximum design pressure. the Reactor Steam Dome Pressure - Low signals are assumed to be OPERABLE and capable of permitting initiation of the ECCS.
The Reactor Steam Dome Pressure - Low signals are initiated from four pressure transmitters that sense the reactor dome pressure. The transmitters are connected to four trip units. The outputs of the trip units are connected to relays whose contacts are arranged in a one-out-of-two taken twice logic.
The Allowable Value is low enough to prevent overpressuring the equipment in the low pressure ECCS.
The four channels of Reactor Steam Dome Pressure - Low Function are required to be OPERABLE in MODES 4 and 5 when ECCS manual initiation is required to be OPERABLE by LCO 3.5.2.
SUSQUEHANNA - UNIT 1 B 3.3-134C
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued) 1.b, 2.b. Manual Initiation The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to provide manual initiation capability. There is one push button for each of the CS and LPCI subsystems (i.e., two for CS and two for LPCI).
There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
A channel of the Manual Initiation Function (one channel per subsystem) is required to be OPERABLE in MODES 4 and 5 when the associated ECCS subsystems are required to be OPERABLE per LCO 3.5.2.
RHR System Isolation 3.a - Reactor Vessel Water Level - Low, Level 3 The definition of DRAIN TIME allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the T AF when actuated by RPV water level isolation instrumentation. The Reactor Vessel Water Level - Low, Level 3 Function associated with RHR System isolation may be credited for automatic isolation of penetration flow paths associated with the RHR System.
Reactor Vessel Water Level - Low. Level 3 signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level - Low, Level 3 Function are available, only two channels Call in the same trip system) are required to be OPERABLE.
The Reactor Vessel Water Level - Low. Level 3 Allowable Value was chosen to be the same as the Primary Containment Isolation Instrumentation Reactor Vessel Water Level - Low. Level 3 Allowable Value (LCO 3.3.6.1), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low. Level 3 Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
SUSQUEHANNA - UNIT 1 B 3.3-134D
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
Reactor Water Cleanup (RWCU) System Isolation 4.a - Reactor Vessel Water level - Low Low, Level 2 The definition of DRAIN TIME allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation. The Reactor Vessel Water Level - Low Low. Level 2 Function associated with RWCU System isolation may be credited for automatic isolation of penetration flow paths associated with the RWCU System.
Reactor Vessel Water Level - Low Low, Level 2 signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level -
Low Low, Level 2 Function are available, only two channels (all in the same trip system) are required to be OPERABLE.
The Reactor Vessel Water Level - Low Low, Level 2 Allowable Value was chosen to be the same as the ECCS Reactor Vessel Water Level - Low Low. Level 2 Allowable Value (LCO 3.3.5.1). since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low Low, Level 2 Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
SUSQUEHANNA - UNIT 1 B 3.3-134E
BASES ACTIONS Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 A Note has been provided to modify the ACTIONS related to RPV Water Inventory Control instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions continue to apply for each additional failure. with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable RPV Water Inventory Control instrumentation channels provide appropriate compensatory measures for separate inoperable Condition entry for each inoperable RPV Water Inventory Control instrumentation channel.
Required Action A.1 directs entry into the appropriate Condition referenced in Table 3.3.5.2-1. The applicable Condition referenced in the Table is Function dependent. Each time a channel is discovered inoperable. Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
B.1 and B.2 RHR System Isolation, Reactor Vessel Water Level - Low Level 3, and Reactor Water Cleanup System, Reactor Vessel Water Level - Low Low, Level 2 functions are applicable when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME. If the instrumentation is inoperable, Required Action B.1 directs an immediate declaration that the associated penetration flow path(s) are incapable of automatic isolation. Required Action B.2 directs calculation of DRAIN TIME. The calculation cannot credit automatic isolation of the affected penetration flow paths.
SUSQUEHANNA - UNIT 1 B 3.3-134F
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 ACTIONS (continued)
Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. If the permissive is inoperable, manual initiation of ECCS is prohibited. Therefore, the permissive must be placed in the trip condition within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. With the permissive in the trip condition, manual initiation may be performed. Prior to placing the permissive in the tripped condition. the operator can take manual control of the pump and the injection valve to inject water into the RPV.
The Completion Time of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is intended to allow the operator time to evaluate any discovered inoperabilities and to place the channel in trip.
If a manual initiation function is inoperable, the ECCS subsystem pumps can be started manually and the valves can be opened manually, but this is not the preferred condition.
The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time was chosen to allow time for the operator to evaluate and repair any discovered inoperabilities. The Completion Time is appropriate given the ability to manually start the ECCS pumps and open the injection valves.
With the Required Action and associated Completion Time of Condition C or D not met. the associated low pressure ECCS injection/spray subsystem may be incapable of performing the intended function. and must be declared inoperable immediately.
SUSQUEHANNA - UNIT 1 B 3.3-134G
BASES SURVEILLANCE REQUIREMENTS Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 As noted in the beginning of the SRs, the SRs for each RPV Water Inventory Control instrument Function are found in the SRs column of Table 3.3.5.2-1.
SR 3.3.5.2.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a similar parameter on other channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK guarantees that undetected outright channel failure is limited; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL FUNCTIONAL TEST.
Agreement criteria are determined by the plant staff, based on a combination of the channel instrument uncertainties. including indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The CHANNEL CHECK supplements less formal. but more frequent.
checks of channels during normal operational use of the displays associated with the channels required by the LCO.
SR 3.3.5.2.2 A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function.
This SR is modified by a Note that provides a general exception to the definition of CHANNEL FUNCTIONAL TEST. This exception is necessary because the design of instrumentation does not facilitate functional testing of all required contacts of the relay which input into the combinational logic.
Performance of such a test could result in a plant transient or place the plant in an undue risk situation. Therefore. for this SR, the CHANNEL FUNCTIONAL TEST verifies acceptable response by verifying the change of state of the relay which inputs into the combinational logic. The required contacts not tested during the CHANNEL FUNCTIONAL TEST are tested under the LOGIC SYSTEM FUNCTIONAL TEST. SR 3.3.5.2.3. This is acceptable because operating experience shows that the contacts not tested during the CHANNEL FUNCTIONAL TEST normally pass the SUSQUEHANNA - UNIT 1 B 3.3-134H
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 SURVEILLANCE REQUIREMENTS (continued)
SR 3.3.5.2.2 (Continued)
REFERENCES LOGIC SYSTEM FUNCTIONAL TEST, and the testing methodology minimizes the risk of unplanned transients.
Any setpoint adjustment shall be consistent with the assumptions of the current plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.3.5.2.3 The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic for a specific channel. The system functional testing performed in LCO 3.5.2 overlaps this Surveillance to complete testing of the assumed safety function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
- 1.
Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup,"
November 1984.
- 2.
Information Notice 86-74, "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves." August 1986.
- 3.
Generic Letter 92-04. "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10 CFR 50.54(F). "August 1992.
- 4.
NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs," May 1993.
- 5.
Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1." July 1994.
SUSQUEHANNA - UNIT 1 B 3.3-1341
RCIC System Instrumentation B 3.3.5.~~
B 3.3 INSTRUMENTATION B 3. 3. 5.~~
Reactor Core Isolation Cooling (RCIC) System Instrumentation BASES BACKGROUND The purpose of the RCIC System instrumentation is to initiate actions to ensure adequate core cooling when the reactor vessel is isolated from its primary heat sink (the main condenser) and normal coolant makeup flow from the Reactor Feedwater System is unavailable, such that initiation of the low pressure Emergency Core Cooling Systems (ECCS) pumps does not occur.
A more complete discussion of RCIC System operation is provided in the Bases of LCO 3.5.3, "RCIC System."
The RCIC System may be initiated by either automatic or manual means.
Automatic initiation occurs for conditions of reactor vessel Low Low water level. The variable is monitored by four instruments. The outputs of the trip units are connected to relays whose contacts are arranged in a one-out-of-two taken twice logic arrangement. Once initiated, the RCIC logic seals in and can be reset by the operator only when the reactor vessel water level signals have cleared.
The RCIC test line isolation valve is closed on a RCIC initiation signal to allow full system flow and maintain primary containment isolated in the event RCIC is not operating.
The RCIC System also monitors the water levels in the condensate storage tank (CST) which is the normal suction source of reactor grade water for RCIC. Upon receipt of a RCIC initiation signal, the CST suction valve is automatically signaled to open (it is normally in the open position) unless the pump suction from the suppression pool valve is open. If the water level in the CST falls below a preselected level, first the suppression pool suction valve automatically opens, and then the CST suction valve automatically closes. Two level switches are used to detect low water level in the CST.
Either switch can cause the suppression pool suction valve to open and the CST suction valve to close.
The RCIC System provides makeup water to the reactor until the reactor vessel water level reaches the high water level (continued)
SUSQUEHANNA - UNIT 1 B3.3-135 Revision 0
BASES BACKGROUND (continued)
APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY RCIC System Instrumentation B 3.3.5.'2~
(Level 8) trip (two-out-of-two logic), at which time the RCIC steam supply and cooling water supply valves close (the injection valve also closes due to the closure of the steam supply valves). The RCIC System restarts if vessel level again drops to the low level initiation point (Level 2).
The function of the RCIC System to provide makeup coolant to the reactor is used to respond to transient events. The RCIC System is not an Engineered Safety Feature System and no credit is taken in the safety analyses for RCIC System operation. Based on its contribution to the reduction of overall plant risk, however, the system, and therefore its instrumentation, are included in the Technical Specifications as required by the NRC Policy Statement (Ref. 2). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
The OPERABILITY of the RCIC System instrumentation is dependent upon the OPERABILITY of the individual instrumentation channel Functions specified in Table 3. 3. 5.'2~- 1
. Each Function must have a required number of OPERABLE channels with their setpoints within the specified Allowable Values, where appropriate. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. The actual setpoint is calibrated consistent with applicable setpoint methodology assumptions.
Allowable Values are specified for each RCIC System instrumentation Function specified in the Table. Nominal trip setpoints are specified in the setpoint calculations. The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS. Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable. Each Allowable Value specified accounts for instrument uncertainties appropriate to the Function. These uncertainties are described in the setpoint methodology.
An exception to the methodology described to derive the Allowable Value is the methodology used to determine the Allowable Value for the Condensate Storage Tank Low Level. This Allowable Value is based on a system calculation and (continued)
SUSQUEHANNA - UNIT 1 B3.3-136 Revision G
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
RCIC System Instrumentation B 3.3. 5.2~
and engineering judgement which establishes a conservative limit at which the Function should occur.
The individual Functions are required to be OPERABLE in MODE 1, and in MODES 2 and 3 with reactor steam dome pressure > 150 psig since this is when RCIC is required to be OPERABLE. (Refer to LCO 3.5.3 for Applicability Bases for the RCIC System.)
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
- 1. Reactor Vessel Water Level-Low Low. Level 2 Low reactor pressure vessel (RPV) water level indicates that normal feedwater flow is insufficient to maintain reactor vessel water level and that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, the RCIC System is initiated at Level 2 to assist in maintaining water level above the top of the active fuel.
Reactor Vessel Water Level-Low Low, Level 2 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-Low Low, Level 2 Allowable Value is set high enough such that for complete loss of feedwater flow, the RCIC System flow with high pressure coolant injection assumed to fail will be sufficient to avoid initiation of low pressure ECCS at Level 1.
Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
(continued)
SUSQUEHANNA - UNIT 1 B 3.3-137 Revision G
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
- 2. Reactor Vessel Water Level-High. Level 8 RCIC System Instrumentation B 3.3.5.2;2 High RPV water level indicates that sufficient cooling water inventory exists in the reactor vessel such that there is no danger to the fuel. Therefore, the Level 8 signal is used to close the RCIC steam supply and cooling water supply valves to prevent overflow into the main steam lines (MSLs). (The injection valve also closes due to the closure of the steam supply valve.)
Reactor Vessel Water Level-High, Level 8 signals for RCIC are initiated from two level instruments, which sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-High, Level 8 Allowable Value is high enough to preclude isolating the injection valve of the RCIC during normal operation, yet low enough to trip the RCIC System prior to water overflowing into the MSLs.
Two channels of Reactor Vessel Water Level-High, Level 8 Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
- 3. Condensate Storage Tank Level-Low The Condensate Storage Tank-Low signal indicates that a conservatively calculated NPSH-available limit is being approached. Normally, the suction valve between the RCIC pump and the CST is open and, upon receiving a RCIC initiation signal, water for RCIC injection would be taken from the CST.
However, if the water level in the CST falls below a preselected level, first the suppression pool suction valve automatically opens, and then the CST suction valve automatically closes. This ensures that an adequate suction head for the pump and an uninterrupted supply of makeup water is available to the RCIC pump. This logic also has a manual override function initiated by manual closure of the suppression pool suction valve should it be desired to realign the suction to the remaining reserve volume in the CST. To prevent losing suction to the pump, the suction valves are interlocked so that the suppression pool suction valves must be open before the CST suction valve automatically closes.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-138 Revision-+
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ACTIONS RCIC System Instrumentation B 3.3.5.2~
- 3. Condensate Storage Tank Level-Low (continued)
Two level switches are used to detect low water level in the CST. The Condensate Storage Tank Level-Low Function Allowable Value is set high enough to ensure adequate pump suction head while water is being taken from the CST.
Two channels of Condensate Storage Tank Level-Low Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC swap to suppression pool source. Refer to LCO 3.5.3 for RCIC Applicability Bases.
- 4. Manual Initiation The Manual Initiation push button switch introduces a signal into the RCIC System initiation logic that is redundant to the automatic protective instrumentation and provides manual initiation capability. There is one push button for the RCIC System resulting in a single channel trip Function.
The Manual Initiation Function is not assumed in any accident or transient analyses in the FSAR. However, the Function is retained for overall redundancy and diversity of the RCIC function as required by the NRC in the plant licensing basis.
There is no Allowable Value for this Function since the channel is mechanically actuated based solely on the position of the push button. One channel of Manual Initiation is required to be OPERABLE when RCIC is required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to RCIC System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for (continued)
SUSQUEHANNA - UNIT 1 B3.3-139 Revision Q
BASES ACTIONS (continued)
RCIC System Instrumentation B 3. 3. 5.2~
inoperable RCIC System instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable RCIC System instrumentation channel.
Required Action A.1 directs entry into the appropriate Condition referenced in Table 3. 3. 5.2~- 1
. The applicable Condition referenced in the Table is Function dependent. Each time a channel is discovered to be inoperable, Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
B.1 and B.2 Required Action B.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in a complete loss of automatic initiation capability for the RCIC System. In this case, automatic initiation capability is lost if two Function 1 channels in the same trip system are inoperable and untripped. In this situation (loss of automatic initiation capability), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Action B.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after discovery of loss of RCIC initiation capability.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action B.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically initiated due to two inoperable, untripped Reactor Vessel Water Level-Low Low, Level 2 channels in the same trip system. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time from discovery of loss of initiation capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
(continued)
SUSQUEHANNA - UNIT 1 B 3.3-140 Revision G
BASES ACTIONS B.1 and B.2 (continued)
RCIC System Instrumentation B 3. 3. 5.~~
Because of the redundancy of sensors available to provide initiation signals and the fact that the RCIC System is not assumed in any accident or transient analysis, an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed in the tripped condition per Required Action B.2. Placing the inoperable channel in trip would conservatively compensate for the inoperability, restore capability to accommodate a single failure, and allow operation to continue. Alternately, if it is not desired to place the channel in trip (e.g., as in the case where placing the inoperable channel in trip would result in an initiation), Condition E must be entered and its Required Action taken.
A risk based analysis was performed and determined that an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (Ref. 1) is acceptable to permit restoration of any inoperable channel to OPERABLE status (Required Action C.1). A Required Action (similar to Required Action B.1) limiting the allowable out of service time, if a loss of automatic RCIC initiation capability exists, is not required.
This Condition applies to the Reactor Vessel Water Level-High, Level 8 Function whose logic is arranged such that any inoperable channel will result in a loss of automatic RCIC trip protection capability. As stated above, this loss of automatic RCIC trip protection capability was analyzed and determined to be acceptable. This Condition also applies to the Manual Initiation Function. Since this Function is not assumed in any accident or transient analysis, a total loss of manual initiation capability (Required Action C.1) for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is allowed. The Required Action does not allow placing a channel in trip since this action would not necessarily result in a safe state for the channel in all events.
(continued)
SUSQUEHANNA - UNIT 1 B 3.3-141 Revision G
BASES ACTIONS (continued)
D.1. D.2.1. and D.2.2 RCIC System Instrumentation B 3.3. 5.~~
Required Action D.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in automatic component initiation capability being lost for the feature(s). For Required Action D.1, the RCIC System is the only associated feature. In this case, automatic initiation capability is lost if two Function 3 channels are inoperable and untripped. In this situation (loss of automatic suction swap),
the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Actions D.2.1 and D.2.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from discovery of loss of RCIC initiation capability. A note identifies that required Action D.1 is only applicable if the RCIC pump suction is not aligned to the suppression pool since, if aligned, the Function is already performed. This allows the RCIC pump suction to be realigned to the suppression pool within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, if desired.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action D.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically aligned to the suppression pool due to two inoperable, untripped channels in the same Function. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time from discovery of loss of initiation capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
Because of the redundancy of sensors available to provide initiation signals and the fact that the RCIC System is not assumed in any accident or transient analysis, an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed in the tripped condition per Required Action D.2.1, which performs the intended function of the channel (shifting the suction source to the suppression pool). Alternatively, Required Action D.2.2 allows the manual alignment of the RCIC suction (continued)
SUSQUEHANNA - UNIT 1 B 3.3-142 Revision G
BASES ACTIONS SURVEILLANCE REQUIREMENTS D.1, D.2.1, and D.2.2 (continued)
RCIC System Instrumentation B 3. 3. 5.2~
to the suppression pool, which also performs the intended function. If it is not desired to perform Required Actions D.2.1 and D.2.2, Condition E must be entered and its Required Action taken.
With any Required Action and associated Completion Time not met, the RCIC System may be incapable of performing the intended function, and the RCIC System must be declared inoperable immediately As noted in the beginning of the SRs, the SRs for each RCIC System instrumentation Function are found in the SRs column of Table 3.3. 5.2~-1 The Surveillances are modified by a Note to indicate that when a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for Function 2 and 4; and (b) for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for Functions other than Function 2 and 4, provided the associated Function maintains trip capability. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken. This Note is based on the reliability analysis (Ref. 1) assumption of the average time required to perform channel surveillance. That analysis demonstrated that the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> testing allowance does not significantly reduce the probability that the RCIC will initiate when necessary.
SR 3.3.5.23.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a parameter on other similar (continued)
SUSQUEHANNA - UNIT 1 B 3.3-143 Revision G
BASES RCIC System Instrumentation B 3. 3.5.2~
SURVEILLANCE SR 3.3.5.23.1 (continued)
REQUIREMENTS channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.
Agreement criteria which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties, may be used to support this parameter comparison and include indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit, and does not necessarily indicate the channel is Inoperable.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program. The CHANNEL CHECK supplements less formal checks of channels during normal operational use of the displays associated with the channels required by the LCO.
SR 3.3.5.23.2 A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program..
This SR is modified by a Note that provides a general exception to the definition of CHANNEL FUNCTIONAL TEST. This exception is necessary because the design of instrumentation does not facilitate functional testing of all required contacts of the relay which input into the combinational logic.
(Reference 3) Performance of such a test could result in a plant transient or place the plant in an undo risk situation. Therefore, for this SR, the CHANNEL FUNCTIONAL TEST verifies acceptable response by verifying (continued)
SUSQUEHANNA - UNIT 1 B 3.3-144 Revision Q
BASES RCIC System Instrumentation B 3. 3. 5.2~
SURVEILLANCE SR 3.3.5.23.2 (continued)
REQUIREMENTS the change of state of the relay which inputs into the combinational logic. The required contacts not tested during the CHANNEL FUNCTIONAL TEST are tested under the LOGIC SYSTEM FUNCTIONAL TEST, SR 3. 3.5.2~. 5. This is acceptable because operating experience shows that the contacts not tested during the CHANNEL FUNCTIONAL TEST normally pass the LOGIC SYSTEM FUNCTIONAL TEST, and the testing methodology minimizes the risk of unplanned transients.
SR 3.3.5.23.3 and SR 3.3.5.23.4 A CHANNEL CALIBRATION verifies that the channel responds to the measured parameter within the necessary range and accuracy. CHANNEL CALIBRATION leaves the channel adjusted to account for instrument drifts between successive calibrations consistent with the plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program..
SR 3.3.5.23.5 The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic for a specific channel. The system functional testing performed in LCO 3.5.3 overlaps this Surveillance to provide complete testing of the safety function.
(continued)
SUSQUEHANNA - UNIT 1 B 3.3-145 Revision G
BASES RCIC System Instrumentation B 3.3.5.2~
SURVEILLANCE SR 3.3.5.23.5 (continued)
REQUIREMENTS REFERENCES The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
- 1. NEDE-770-06-2, "Addendum to Bases for Changes to Surveillance Test Intervals and Allowed Out-of-Service Times for Selected Instrumentation Technical Specifications," February 1991.
- 2. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 32193).
- 3. NRC Inspection and Enforcement Manual, Part 9900: Technical Guidance, Standard Technical Specification Section 1.0 Definitions, Issue date 12/08/86.
SUSQUEHANNA - UNIT 1 B 3.3-146 Revision G
~------------------------------------------
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
Primary Containment Isolation Instrumentation B 3.3.6.1 6.b. Reactor Vessel Water Level-Low. Level 3 Low RPV water level indicates that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, isolation of some reactor vessel interfaces occurs to begin isolating the potential sources of a break. The Reactor Vessel Water Level-Low, Level 3 Function associated with RHR Shutdown Cooling System isolation is not directly assumed in safety analyses because a break of the RHR Shutdown Cooling System is bounded by breaks of the recirculation and MSL.
The RHR Shutdown Cooling System isolation on Level 3 supports actions to ensure that the RPV water level does not drop below the top of the active fuel during a vessel draindown event caused by a leak (e.g., pipe break or inadvertent valve opening) in the RHR Shutdown Cooling System.
Reactor Vessel Water Level-Low, Level 3 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels (two channels per trip system) of the Reactor Vessel Water Level-Low, Level 3 Function are available and are required to be OPERABLE to ensure that no single instrument failure can preclude the isolation function. As noted (footnote (c) to Table 3.3.6.1 1 ), only t>.vo channels of the Reactor Vessel Water Level Low, Level 3 Function are required to be OPERABLE in MODES 4 and 5 (and must input into the same trip system), provided the RHR Shutdm*m Cooling System integrity is maintained. System integrity is maintained provided the piping is intact and no maintenance is being performed that has the potential for draining the reactor vessel through the system.
The Reactor Vessel Water Level-Low, Level 3 Allowable Value was chosen to be the same as the RPS Reactor Vessel Water Level-Low, Level 3 Allowable Value (LCO 3.3.1.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level-Low, Level 3 Function is only required to be OPERABLE in MODES 3, 4, and 5 to prevent this potential flow path from lowering the reactor vessel level to the top of the fuel.
(continued)
SUSQUEHANNA - UNIT 1 B 3.3-169 Revision+
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY Primary Containment Isolation Instrumentation B 3.3.6.1 6.b. Reactor Vessel Water Level-Low. Level 3 (continued)
In MODES 1 and 2, another isolation (i.e., Reactor Steam Dome Pressure-High) and administrative controls ensure that this flow path remains isolated to prevent unexpected loss of inventory via this flow path.
6.c Manual Initiation The Manual Initiation push button channels introduce signals to RHR Shutdown Cooling System isolation logic that is redundant to the automatic protective instrumentation and provide manual isolation capability. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for overall redundancy and diversity of the isolation function as required by the NRC in the plant licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of the Manual Initiation Function are available and are required to be OPERABLE in MODE~ 3, 4, and 5, since these are the MODES in which the RHR Shutdown Cooling System Isolation automatic function are required to be OPERABLE.
As noted (f.ootnote (c) to Table 3.3.6.1 1), only one channel of the Manual Initiation function is required to be OPERABLE in MODES 4 and 5 provided the RHR Shutdown Cooling System integrity is maintained.
System integrity is maintained provided the piping is intact and no maintenance is being perf.ormed that has the potential for draining the reactor vessel through the system.
Traversing lncore Probe System Isolation 7.a Reactor Vessel Water Level - Low. Level 3 Low RPV water level indicates that the capability to cool the fuel may be threatened. The valves whose penetrations communicate with the primary containment are isolated to limit the release of fission products. The isolation of the primary containment on Level 3 supports actions to ensure that offsite and control room dose regulatory limits are not exceeded.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-170 Revision J
BASES ACTIONS (continued)
H.1 and H.2 Primary Containment Isolation Instrumentation B 3.3.6.1 If the channel is not restored to OPERABLE status or placed in trip within the allowed Completion Time, or any Required Action of Condition F or G is not met and the associated Completion Time has expired, the plant must be placed in a MODE or other specified condition in which the LCO does not apply. This is done by placing the plant in at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
1.1 and 1.2 If the channel is not restored to OPERABLE status or placed in trip within the allowed Completion Time, the associated SLC subsystem(s) is declared inoperable or the RWCU System is isolated. Since this Function is required to ensure that the SLC System performs its intended function,
sufficient remedial measures are provided by declaring the associated SLC subsystems inoperable or isolating the RWCU System.
The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is acceptable because it minimizes risk while allowing sufficient time for personnel to isolate the RWCU System.
J.1 and J.2 If the channel is not restored to OPERABLE status or placed in trip within the allowed Completion Time, the associated penetration flow path should be closed. However, if the shutdown cooling function is needed to provide core cooling, these Required Actions allow the penetration flow path to remain unisolated provided action is immediately initiated to restore the channel to OPERABLE status~ or to isolate the RHR Shutdown Cooling System (i.e., provide alternate decay heat removal capabilities so the penetration flow path can be isolated). Actions must continue until the channel is restored to OPERABLE status or the RHR Shutdown Cooling System is isolated.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-176 Revision+
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY Secondary Containment Isolation Instrumentation B 3.3.6.2
- 1. Reactor Vessel Water Level-Low Low, Level 2 (continued) level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available and are required to be OPERABLE to ensure that no single instrument failure can preclude the isolation function.
The Reactor Vessel Water Level-Low Low, Level 2 Allowable Value was chosen to be the same as the High Pressure Coolant Injection/Reactor Core Isolation Cooling (HPCl/RCIC) Reactor Vessel Water Level-Low Low, Level 2 Allowable Value (LCO 3.3.5.1 and LCO 3. 3.5.2~. since this could indicate that the capability to cool the fuel is being threatened.
The Reactor Vessel Water Level-Low Low, Level 2 Function is required to be OPERABLE in MODES 1, 2, and 3 where considerable energy exists in the Reactor Coolant System (RCS); thus, there is a probability of pipe breaks resulting in significant releases of radioactive steam and gas. In MODES 4 and 5, the probability and consequences of these events are low due to the RCS pressure and temperature limitations of these MODES; thus, this Function is not required. In addition, the Function is also required to be OPERABLE during operations with a potential for draining the reactor vessel (OPDRVs) because the capability of isolating potential sources of leakage must be provided to ensure that offsite and control room dose limits are not exceeded if core damage occurs.
Reactor Vessel Water Level-Low Low, Level 2 will isolate the affected Unit's zone (i.e., Zone I for Unit 1 and Zone II for Unit 2) and Zone Ill.
- 2. Drywell Pressure-High High drywell pressure can indicate a break in the reactor coolant pressure boundary (RCPB). An isolation of the secondary containment and actuation of the SGT System are initiated in order to minimize the potential of an offsite dose release. The isolation on high drywell pressure supports actions to ensure that any offsite releases are within the limits calculated in the safety analysis. However, the Drywell Pressure-High Function associated with (continued)
SUSQUEHANNA - UNIT 1 B3.3-183 Revision 2
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY Secondary Containment Isolation Instrumentation B 3.3.6.2 3, 4, 5, 6, 7 Refuel Floor High Exhaust Duct. Refuel Floor Wall Exhaust Duct. and Railroad Access Shaft Exhaust Duct Radiation-High (continued)
The Exhaust Radiation-High signals are initiated from radiation detectors that are located on the ventilation exhaust ductwork coming from the refueling floor zones and the Railroad Access Shaft. The signal from each detector is input to an individual monitor whose trip outputs are assigned to an isolation channel. Eight channels of Refuel Floor High Exhaust Duct and Wall Exhaust Duct Radiation-High Function (four from Unit 1 and four from Unit 2) and two channels of Railroad Access Shaft Exhaust Duct Radiation - High Function (both from Unit 1) are available to ensure that no single instrument failure can preclude the isolation function.
Operability of the Unit 1 and Unit 2 Refuel Floor High Exhaust Duct Radiation Instrumentation and the Unit 1 and Unit 2 Refuel Floor Wall Exhaust Duct Radiation Instrumentation does not require HVAC system airflow in the ductwork.
The Allowable Values are chosen to promptly detect gross failure of the fuel cladding.
The Refuel Floor Exhaust Radiation-High Functions are required to be OPERABLE during CORE ALTERATIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, because the capability of detecting radiation releases due to fuel failures (due to a fuel handling accident) must be provided to ensure that offsite and control room dose limits are not exceeded.
The Railroad Access Shaft Exhaust Duct Radiation-High Function is only required to be OPERABLE during handling of irradiated fuel within the Railroad Access Shaft, and directly above the Railroad Access Shaft with the Railroad Access Shaft Equipment Hatch open. This provides the capability of detecting radiation releases due to fuel failures resulting from dropped fuel assemblies which ensures that offsite and control room dose limits are not exceeded.
Refuel Floor High and Wall Exhaust Duct and Railroad Access Shaft Exhaust Duct Radiation - High Functions will isolate Zone Ill of secondary containment.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-185 Revision 4
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
ACTIONS
- 8. Manual Initiation Secondary Containment Isolation Instrumentation B 3.3.6.2 A Manual Initiation can be performed for secondary containment isolation by initiating a Primary Containment Isolation. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for the overall redundancy and diversity of the secondary containment isolation instrumentation as required by the NRC approved licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function, since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of Manual Initiation Function are available and are required to be OPERABLE in MODES 1, 2, and 3, and during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment. These are the MODES and other specified conditions in which the Secondary Containment Isolation automatic Functions are required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to secondary containment isolation instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable secondary containment isolation instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable secondary containment isolation instrumentation channel.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-186 Revision 4-
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
CREOAS System Instrumentation B 3.3.7.1 function in harsh environments as defined by 10 CFR 50.49) are accounted for.
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
- 1. Reactor Vessel Water Level-Low Low, Level 2 Low reactor pressure vessel (RPV) water level indicates that the capability of cooling the fuel may be threatened. A low reactor vessel water level could indicate a LOCA and will automatically initiate the CREOAS System, since this could be a precursor to a potential radiation release and subsequent radiation exposure to control room personnel.
Reactor Vessel Water Level-Low Low, Level 2 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available (two channels per trip system) and are required to be OPERABLE to ensure that no single instrument failure can preclude a CREOAS System initiation. The Reactor Vessel Water Level-Low Low, Level 2 Allowable Value was chosen to be the same as the HPCI and RCIC Reactor Vessel Water Level-Low Low Low, Level 1 Allowable Value (LCO 3.3.5.1, "ECCS Instrumentation and LCO 3. 3. 5.-2-~"RCIC Instrumentation").
The Reactor Vessel Water Level-Low Low, Level 2 Function is required to be OPERABLE in MODES 1, 2, and 3, and during operations with a potential f.or draining the reactor vessel (OPDRVs) to ensure that the control room personnel are protected during a LOCA. In MODES 4 and 5 at times other than OPDRVs, the probability of a vessel draindown event resulting in a release of radioactive material into the environment is minimal. In addition, adequate protection is performed by the Control Room Air Inlet Radiation-High Function. Therefore, this Function is not required in other MODES and specified conditions.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-194 Revision G
I BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY CREOAS System Instrumentation B 3.3.7.1
- 3. 4. 5. 6. 7 Refuel Floor High Exhaust Duct. Refuel Floor Wall Exhaust Duct and Railroad Access Shaft Exhaust Duct Radiation-High (continued)
Duct Radiation-High Function (four from Unit 1 and four from Unit 2), and two channels of the Railroad Access Shaft Exhaust Radiation - High Function (both from Unit 1) are available and are required to be OPERABLE when the associated Refuel Floor Exhaust System is in operation to ensure that no single instrument failure can preclude the initiation function.
The Allowable Values are chosen to promptly detect gross failure of the fuel cladding. The Refuel Floor Exhaust Duct and Wall Exhaust Duct Radiation-High are required to be OPERABLE during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, because the capability of detecting radiation releases due to fuel failures ~due to fuel uncovery or dropped fuel assemblies) must be provided to ensure that offsite and control room dose limits are not exceeded.
The Railroad Access Shaft Exhaust Duct Radiation - High Function is only required to be OPERABLE during handling of irradiated fuel within the Railroad Access Shaft, and directly above the Railroad Access Shaft with the Railroad Access Shaft Equipment Hatch open, because the capability of detecting radiation releases due to fuel failures ~dropped fuel assemblies) must be provided to ensure that offsite and control room dose limits are not exceeded.
- 8. Main Control Room Outside Air Intake Radiation-High The main control room outside air intake radiation monitors measure radiation levels at the control structure outside air intake duct. A high radiation level may pose a threat to main control room personnel; thus, automatically initiating the CREOAS System. The Control Room Air Inlet Radiation-High Function consists of two independent monitors. Two channels of Control Room Air Inlet Radiation-High are available and are required to be OPERABLE to ensure that no single instrument failure can preclude CREOAS System initiation. The Allowable Value was selected to ensure protection of the control room personnel.
(continued)
SUSQUEHANNA - UNIT 1 B3.3-196 Revision -2
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ACTIONS CREOAS System Instrumentation B 3.3.7.1
- 8. Main Control Room Outside Air Intake Radiation-High (continued)
The Control Room Air Inlet Radiation-High Function is required to be OPERABLE in MODES 1, 2, and 3 and during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, to ensure that control room personnel are protected during a LOCA..QJ:, fuel handling event, or vessel draindovm event. During MODES 4 and 5, when these specified conditions are not in progress (e.g.,
CORE ALTERATIONS), the probability of a LOCA or fuel damage is low; thus, the Function is not required.
- 9. Manual Initiation A Manual Initiation can be performed for CREOAS isolation by initiating a Primary Containment Isolation. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for the overall redundancy and diversity of the secondary containment isolation instrumentation as required by the NRC approved licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function, since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of Manual Initiation Function are available and are required to be OPERABLE in MODES 1, 2, and 3, and during CORE AL TERA TIO NS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment. These are the MODES and other specified conditions in which the Secondary Containment Isolation automatic Functions are required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to CREOAS System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate (continued)
SUSQUEHANNA - UNIT 1 B3.3-197 Revision Q
B 3.5 B 3.5.1 BASES ECCS-Operating B 3.5.1 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM ECCS-Operating BACKGROUND The ECCS is designed, in conjunction with the primary and secondary containment, to limit the release of radioactive materials to the environment following a loss of coolant accident (LOCA). The ECCS uses two independent methods (flooding and spraying) to cool the core during a LOCA. The ECCS network consists of the High Pressure Coolant Injection (HPCI) System, the Core Spray (CS) System, the low pressure coolant injection (LPCI) mode of the Residual Heat Removal (RHR) System, and the Automatic Depressurization System (ADS). The suppression pool provides the required source of water for the ECCS. Although no credit is taken in the safety analyses for the condensate storage tank (CST), it is capable of providing a source of water for the HPCI and CS systems.
On receipt of an initiation signal, ECCS pumps automatically start; simultaneously, the system aligns and the pumps inject water, taken either from the CST or suppression pool, into the Reactor Coolant System (RCS) as RCS pressure is overcome by the discharge pressure of the ECCS pumps. Although the system is initiated, ADS action is delayed, allowing the operator to interrupt the timed sequence if the system is not needed. The HPCI pump discharge pressure quickly exceeds that of the RCS, and the pump injects coolant into the vessel to cool the core. If the break is small, the HPCI System will maintain coolant inventory as well as vessel level while the RCS is still pressurized. If HPCI fails, it is backed up by ADS in combination with LPCI and CS. In this event absent operator action, the ADS timed sequence would time out and open the selected safety/relief valves (S/RVs) depressurizing the RCS, thus allowing the LPCI and CS to overcome RCS pressure and inject coolant into the vessel. If the break is large, RCS pressure initially drops rapidly and the LPCI and CS cool the core.
Water from the break returns to the suppression pool where it is used again and again. Water in the suppression pool is circulated through a heat exchanger cooled by the RHR Service Water System. Depending on the location and size of (continued)
SUSQUEHANNA - UNIT 1 B 3.5-1 Revision Q
BASES (continued)
APPLICABILITY ACTIONS ECCS-Operating B 3.5.1 All ECCS subsystems are required to be OPERABLE during MODES 1, 2, and 3, when there is considerable energy in the reactor core and core cooling would be required to prevent fuel damage in the event of a break in the primary system piping. In MODES 2 and 3, when reactor steam dome pressure is :::; 150 psig, ADS and HPCI are not required to be OPERABLE because the low pressure ECCS subsystems can provide sufficient flow below this pressure. EGGS rRequirements for MODES 4 and 5 are specified in LCO 3.5.2, "Reactor Pressure Vessel (RPV) Water Inventory ControlEGGS Shutdown."
A Note prohibits the application of LCO 3.0.4.b to an inoperable HPCI subsystem. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable HPCI subsystem and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
If any one low pressure ECCS injection/spray subsystem is inoperable for reasons other than Condition B, the inoperable subsystem must be restored to OPERABLE status within 7 days. In this Condition, the remaining OPERABLE subsystems provide adequate core cooling during a LOCA.
However, overall ECCS reliability is reduced, because a single failure in one of the remaining OPERABLE subsystems, concurrent with a LOCA, may result in the ECCS not being able to perform its intended safety function.
The 7 day Completion Time is based on a reliability study (Ref. 12) that evaluated the impact on ECCS availability, assuming various components and subsystems were taken out of service. The results were used to calculate the average availability of ECCS equipment needed to mitigate the consequences of a LOCA as a function of allowed outage times (i.e.,
Completion Times).
If one LPCI pump in one or both LPCI subsystems is inoperable, the inoperable LPCI pumps must be restored to OPERABLE status within 7 days. In this Condition, the remaining OPERABLE LPCI pumps and at least one CS subsystem (continued)
SUSQUEHANNA - UNIT 1 B 3.5-6 Revision+
EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 B 3.5 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM B 3.5.2 Reactor Pressure Vessel (RPV) Water Inventory ControlECCS Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES The RPV contains penetrations below the top of the active fuel (T AF) that have the potential to drain the reactor coolant inventory to below the TAF.
If the water level should drop below the TAF, the ability to remove decay heat is reduced, which could lead to elevated cladding temperatures and clad perforation. Safety Limit 2.1.1.3 requires the RPV water level to be above the top of the active irradiated fuel at all times to prevent such elevated cladding temperatures.A description of the Core Spray (CS)
System and the Low Pressure Coolant Injection (LPCI) mode of the Residual Heat Removal (RHR) System is provided in the Bases for LCO 3.5.1, "EGGS Operating."
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses. RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material to the environment should an unexpected draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure, reduced piping stresses, and ductile piping systems. Instead, an event is considered in which single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g., seismic event, loss of normal power. single human error).The EGGS performance is evaluated for the entire spectrum of break sizes for a postulated loss of coolant accident (LOCA). The long term cooling analysis following a design basis LOCA (Reference 1) demonstrates that only one low pressure EGGS injection/spray subsystem is required, post LOC,t\\, to maintain adequate reactor vessel water level in the even of an inadvertent vessel draindown.
It is reasonable to assume.Q, based on engineering judgement, that while in MODES 4 and 5, one low pressure ECCS injection/spray subsystem can maintain adequate reactor vessel water level. To provide redundancy, a minimum of two low pressure EGGS injection/spray subsystems are required to be OPERABLE in MODES 4 and 5.
LCO As discussed in References 1, 2, 3. 4, and 5, operating experience has shown RPV water inventory to be significant to public health and safety.
Therefore. RPV Water Inventory Control satisfies Criterion 4 of 10 CFR 50.36(c)(2)(ii).The low pressure EGGS subsystems satisfy Criterion 3 of the NRG Policy Statement (Ref. 2).
The RPV water level must be controlled in MODES 4 and 5 to ensure that if an unexpected draining event should occur. the reactor coolant water level remains above the top of the active irradiated fuel as required by Safety Limit 2.1.1.3.
The Limiting Condition for Operation (LCO) requires the DRAIN TIME of RPV water inventory to the TAF to be ~ 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. A DRAIN TIME of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> is considered reasonable to identify and initiate action to mitigate unexpected draining of reactor coolant. An event that could cause loss of RPV water inventory and result in the RPV water level reaching the TAF in greater than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
-Two-One low pressure ECCS injection/spray subsystems aFe-i§...required to be OPERABLE and capable of being manually started to provide defense-in-depth should an unexpected draining event occur. +Re-A low pressure ECCS injection/spray subsystems consist.§ of either twe-one Core Spray fCSl subsystems af\\Gor twGone Low Pressure Coolant Injection (LPCll subsystems. Each CS subsystem consists of twe-one motor driven pumps, piping, and valves to transfer water from the suppression pool or conden-sate storage tank (CST) to the reactor pressure vessel (RPV1. Each LPCI subsystem consists of one of the two motor driven pumps, piping, and valves to transfer water from the suppression pool to the RPV. Only a single LPCI pump is required per subsystem because of the larger injection capacity in relation to a CS subsystem. In MODES 4 and 5, the RHR System cross tie valves are not required to be closed.
(continued)
SUSQUEHANNA - UNIT 1 B 3.5-19 Revision G
BASES LCO (continued)
APPLICABILITY EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 The LCO is modified by a Note which allows a required LPCI subsystems may be aligned for decay heat removal and to be considered OPERABLE during alignment and operation for decay heat removal for the EGGS function, if they can beif capable of being manually realigned (remote or local) to the LPCI mode and ~are not otherwise inoperable. Alignment and operation for decay heat removal includes when the required RHR pump is not operating or when the system is realigned from or to the RHR shutdown cooling mode. This allowance is necessary since the RHR System may be required to operate in the shutdown cooling mode to remove decay heat and sensible heat from the reactor. Because of the restrictions on DRAIN TIME, sufficient time will be available following an unexpected draining event to manually align and initiate LPCI subsystem operation to maintain RPV water inventory prior to the RPV water level reaching the TAF.lmv pressure and low temperature conditions in MODES 4 and 5, sufficient time will be available to manually align and initiate LPCI subsystem operation to provide core cooling prior to postulated fuel uncovery.
RPV water inventory control is required in MODES 4 and 5. Requirements on water inventory control in other MODES are contained in LCOs in Section 3.3, Instrumentation, and other LCOs in Section 3.5, ECCS, RCIC, and RPV Water Inventory Control. RPV water inventory control is required to protect Safety Limit 2.1.1.3 which is applicable whenever irradiated fuel is in the reactor vessel.OPERABILITY of the lo*N pressure EGGS injection.lspray subsystems is required in MODES 4 and 5 to ensure adequate coolant inventory and sufficient heat removal capability for the irradiated fuel in the core in case of an inadvertent draindm*m of the vessel. Requirements for EGGS OPERABILITY during MODES 1, 2, and 3 are discussed in the Applicability section of the Bases for LCO 3.5.1. EGGS subsystems are not required to be OPERABLE during MODE 5 with the spent fuel storage pool gates removed and the water level maintained at > 22 ft above the RPV flange. This provides sufficient inventory loss prior to fuel uncovery in case of an inadvertent draindown.
The Automatic Depressurization System is not required to be OPERABLE during MODES 4 and 5 because the RPV pressure is < 150 psig, and the CS System and the LPCI subsystems can provide core cooling 1Nithout any depressurization of the primary system.
The High Pressure Coolant Injection System is not required to be OPERABLE during MODES 4 and 5 since the low pressure EGGS injection/spray subsystems can provide sufficient flow to the vessel.
ACTIONS A.1 and 8.1 If any onethe required low pressure ECCS injection/spray subsystem is inoperable, the inoperable subsystem]! must be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. In this Condition, the LCO controls on DRAIN TIME minimize the possibility that an unexpected draining event could necessitate the use of the ECCS injection/spray subsystem, however the defense-in-depth provided by the ECCS injection/spray subsystem is lost. the remaining OPERABLE subsystem can provide sufficient vessel flooding capability to recover from an inadvertent (continued)
SUSQUEHANNA - UNIT 1 B 3.5-20 Revision Q
BASES ACTIONS EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 A.1 and B.1 (continued) vessel draindown. However, overall system reliability is reduced because a single failure in the remaining OPERABLE subsystem concurrent with a vessel draindovm could result in the EGGS not being able to perform its intended function. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time for restoring the required low pressure ECCS injection/spray subsystem to OPERABLE status is based on engineering judgment that consider.§eG the LCO controls on DRAIN TIME tRe remaining available subsystem and the low probability of an unexpected draininga vessel draindown event that would result in loss of RPV water inventory.
Wftl:l-!f_the inoperable ECCS injection/spray subsystem ~not restored to OPERABLE status within the required Completion Time, action must be initiated immediately initiated to establish a method of water injection capable of operating without offsite electrical power. The method of water injection includes the necessary instrumentation and controls, water sources. and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The method of water injection may be manually initiated and may consist of one or more systems or subsystems, and must be able to access water inventory capable of maintaining the RPV water level above the T AF for :::: 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. If recirculation of injected water would occur. it may be credited in determining the necessary water volume.suspend operations with a potential for draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindovm and the subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
C.1. C.2. and C.3 With the DRAIN TIME less than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> but greater than or equal to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. compensatory measures should be taken to ensure the ability to implement mitigating actions should an unexpected draining event occur.
Should a draining event lower the reactor coolant level to below the TAF, there is potential for damage to the reactor fuel cladding and release of radioactive material. Additional actions are taken to ensure that radioactive material will be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a controlled volume in which fission products can be contained, diluted, and processed prior to release to the environment. Required Action C.1 requires verification of the capability to establish the secondary containment boundary in less than the DRAIN TIME.
The required verification confirms actions to establish the secondary containment boundary are preplanned and necessary materials are available. The secondary containment boundary is considered established when one Standby Gas Treatment (SGT) subsystem is capable of maintaining a negative pressure in the secondary containment with respect to the environment. Verification that the secondary containment boundary can be established must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The required verification is an administrative activity and does not require manipulation or testing of equipment. Secondary containment penetration flow paths form a part of the secondary containment boundary. Required Action C.2 requires verification of the capability to isolate each secondary containment penetration flow path in less than the DRAIN TIME. The required verification confirms actions to isolate the secondary containment penetration flow paths are preplanned and necessary materials are available. Power operated valves are not required to receive automatic isolation signals if they can be closed manually within the required time. Verification that the secondary containment penetration flow paths can be isolated must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The required verification is an administrative activity and does not require manipulation or testing of equipment.
One SGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action C.3 requires verification of the capability to place one SGT subsystem in operation in less than the DRAIN TIME. The required verification confirms actions to place a SGT subsystem in operation are preplanned and necessary materials are available. Verification that a SGT subsystem can be placed in operation must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
The required verification is an administrative activity and does not require manipulation or testing of equipment.
D.1, D.2, D.3, and D.4 With the DRAIN TIME less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, mitigating actions are implemented in case an unexpected draining event should occur. Note that if the DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, Required Action E.1 is also applicable.
Required Action D.1 requires immediate action to establish an additional method of water injection augmenting the ECCS injection/spray subsystem required by the LCO. The additional method of water injection includes the necessary instrumentation and controls. water sources. and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The Note to Required Action D.1 states that either the ECCS injection/spray subsystem or the additional method of water injection must be capable of operating without offsite electrical power.
The additional method of water injection may be manually initiated and may consist of one or more systems or subsystems. The additional method of water injection must be able to access water inventory capable of being injected to maintain the RPV water level above the TAF for :::: 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The additional method of water injection and the ECCS injection/spray subsystem may share all or part of the same water sources. If recirculation of injected water would occur. it may be credited in determining the required water volume.
Should a draining event lower the reactor coolant level to below the TAF.
there is potential for damage to the reactor fuel cladding and release of radioactive material. Additional actions are taken to ensure that radioactive material will be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a control volume in which fission products can be contained. diluted, and processed prior to release to the environment. Required Action D.2 requires that actions be immediately initiated to establish the secondary containment boundary. With the secondary containment boundary established, one SGT subsystem is capable of maintaining a negative pressure in the secondary containment with respect to the environment.
The secondary containment penetrations form a part of the secondary containment boundary. Required Action D.3 requires that actions be immediately initiated to verify that each secondary containment penetration flow path is isolated or to verify that it can be manually isolated from the control room.
One SGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action D.4 requires that actions be immediately initiated to verify that at least one SGT subsystem is capable of being placed in operation. The required verification is an administrative activity and does not require manipulation or testing of equipment.
L If the Required Actions and associated Completion times of Conditions C or Dare not met or if the DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, actions must be initiated immediately to restore the DRAIN TIME to 2: 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. In this condition, there may be insufficient time to respond to an unexpected draining event to prevent the RPV water inventory from reaching the TAF.
Note that Required Actions D.1. D.2. D.3, and D.4 are also applicable when DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
C.1, C.2, D.1, D.2, and D.3 VVith both of the required EGGS injection/spray subsystems inoperable, all coolant inventory makeup capability may be unavailable. Therefore, actions must immediately be initiated to suspend OPDRVs to minimize the probability for fission product release. Actions must continue until OPDRVs are suspended. One EGGS injection/spray subsystem must also be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
If at least one low pressure EGGS injection/spray subsystem is not restored to OPERABLE status within the 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time, additional actions are required to minimize any potential fission product release to the environment. This includes ensuring secondary containment is OPERABLE; one standby gas treatment subsystem is OPERABLE; and secondary containment isolation capability (i.e., one isolation valve and associated instrumentation are OPERABLE or other acceptable administrative controls to assure isolation capability) in each secondary containment penetration flow path not isolated and required to be isolated to mitigate radioactivity releases. OPERABILITY may be verified by an administrative check, or by examining logs or other information, to determine whether the components are out of (continued)
SUSQUEHANNA - UNIT 1 B 3.5-21 Revision G
BASES ACTIONS EGGS Shutdo1.vnReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 C.1. C.2. D.1, D.2, and D.3 (continued) service for maintenance or other reasons. It is not necessary to perform the Surveillances needed to demonstrate the OPERABILITY of the components.
If, however, any required component is inoperable, then it must be restored to OPERABLE status. In this case, the Surveillance may need to be performed to restore the component to OPERABLE status. Actions must continue until all required components are OPERABLE.
The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time to restore at least one I01A' pressure EGGS injection/spray subsystem to OPERABLE status ensures that prompt action will be taken to provide the required cooling capacity or to initiate actions to place the plant in a condition that minimizes any potential fission product release to the environment.
SURVEILLANCE SR 3.5.2.1 and SR 3.5.2.2 REQUIREMENTS This Surveillance verifies that the DRAIN TIME of RPV water inventory to the TAF is ;:: 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The period of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> is considered reasonable to identify and initiate action to mitigate draining of reactor coolant. Loss of RPV water inventory that would result in the RPV water level reaching the TAF in greater than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
The definition of DRAIN TIME states that realistic cross-sectional areas and drain rates are used in the calculation. A realistic drain rate may be determined using a single, step-wise. or integrated calculation considering the changing RPV water level during a draining event. For a Control Rod RPV penetration flow path with the Control Rod Drive Mechanism removed and not replaced with a blank flange, the realistic cross-sectional area is based on the control rod blade seated in the control rod guide tube. If the control rod blade will be raised from the penetration to adjust or verify seating of the blade, the exposed cross-sectional area of the RPV penetration flow path is used.
The definition of DRAIN TIME excludes from the calculation those penetration flow paths connected to an intact closed system. or isolated by manual or automatic valves that are locked. sealed. or otherwise secured in the closed position, blank flanges, or other devices that prevent flow of reactor coolant through the penetration flow paths. A blank flange or other bolted device must be connected with a sufficient number of bolts to prevent draining in the event of an Operating Basis Earthquake. Normal or expected leakage from closed systems or past isolation devices is permitted.
Determination that a system is intact and closed or isolated must consider the status of branch lines and ongoing plant maintenance and testing activities.
J
The Residual Heat Removal (RHR) Shutdown Cooling System is only considered an intact closed system when misalignment issues (Reference 6) have been precluded by functional valve interlocks or by isolation devices.
such that redirection of RPV water out of an RHR subsystem is precluded.
Further. RHR Shutdown Cooling System is only considered an intact closed system if its controls have not been transferred to Remote Shutdown, which disables the interlocks and isolation signals.
The exclusion of penetration flow paths from the determination of DRAIN TIME must consider the potential effects of a single operator error or initiating event on items supporting maintenance and testing (rigging, scaffolding, temporary shielding. piping plugs, snubber removal, freeze seals. etc.). If failure of such items could result and would cause a draining event from a closed system or between the RPV and the isolation device, the penetration flow path may not be excluded from the DRAIN TIME calculation.
Surveillance Requirement 3.0.1 requires SRs to be met between performances. Therefore, any changes in plant conditions that would change the DRAIN TIME requires that a new DRAIN TIME be determined.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.2 and SR 3.5.2.3 The minimum water level of 20 ft 0 inches required for the suppression pool is periodically verified to ensure that the suppression pool will provide adequate net positive suction head (NPSH) for the CS subsystemSystem aRG..QI LPCI subsystem pumps, recirculation volume, and vortex prevention.
With the suppression pool water level less than the required limit, the required ECCS injection/spray subsystem is inoperable unless aligned to an OPERABLE CST.all EGGS injection/spray subsystems are inoperable unless they are aligned to an OPERABLE CST.
When suppression pool level is < 20 ft 0 inches, ti he required CS System is considered OPERABLE ooty-if it can take suction from the CST, and the CST water level is sufficient to provide the required NPSH for the CS pump.
Therefore, a verification that either the suppression pool water level is ~ 20 ft 0 inches or that a required CS subsystem is aligned to take suction from the CST and the CST contains ~ 135,000 gallons of water, equivalent to 49% of capacity, ensures that the CS Subsystem can supply at least 135,000 gallons of makeup water to the RPV. However, as noted, only one required CS subsystem may take credit for the CST option during OPDRVs. During OPDRVs, the volume in the CST may not provide adequate makeup if the RPV were completely drained. Therefore, only one CS subsystem is allowed to use the CST. This ensures (continued)
SUSQUEHANNA - UNIT 1 B 3.5-22 Revision Q
BASES EGGS ShutdovmReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 SURVEILLANCE SR 3.5.2.-1--2 and SR 3.5.2.2---L (continued)
REQUIREMENTS the other required EGGS subsystem has adequate makeup volume.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.4 The flow path piping has the potential to develop voids and pockets of entrained air. Maintaining the pump discharge lines of the required ECCS injection/spray subsystems full of water ensures that the ECCS subsystem will perform properly. This may also prevent a water hammer following an ECCS initiation signal. One acceptable method of ensuring that the lines are full is to vent at the high points.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.3, SR 3.5.2.5, SR 3.5.2.6, and SR 3.5.2.7 The Bases provided for SR 3.5.1.1, SR 3.5.1.7, SR 3.5.1.10, and SR 3.5.1.13 are applicable to SR 3.5.2.3, SR 3.5.2.5, SR 3.5.2.6 and SR 3.5.2.7, respectively.
SR 3.5.2.45 Verifying the correct alignment for manual, power operated, and automatic valves in the required ECCS subsystem flow paths provides assurance that the proper flow paths will ~be available for ECCS operation. This SR does not apply to valves that are locked, sealed, or otherwise secured in position, since these valves were verified to be in the correct position prior to locking, sealing, or securing. A valve that receives an initiation signal is allowed to be in a nonaccident position provided the valve will automatical-ly reposition in the proper stroke time. This SR does not require any testing or valve manipulation; rather, it involves verification that those valves capable of potentially being mispositioned are in the correct position. This SR does not apply to valves that cannot be inadvertently misaligned, such as check valves. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
In MODES 4 and 5, the RHR System may operate in the shutdown cooling mode to remove decay heat and sensible heat from the reactor. Therefore, RHR valves that are required for LPGI (continued)
SUSQUEHANNA-UNIT 1 B 3.5-23 Revision+
BASES EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 SURVEILLANCE SR 3.5.2.4 (oontinued)
REQUIREMENTS subsystem operation may be aligned for deoay heat removal. Therefore, this SR is modified by a Note that allov1s LPGI subsystems of the RHR System to be oonsidered OPERABLE for the EGGS funotion if all the required valves in the LPGI flow path oan be manually realigned (remote or looal) to allow injeotion into the RPV, and the systems are not otherwise inoperable. This
'Nill ensure adequate sore oooling if an inadvertent RPV draindown should GGGUf:-
SR 3.5.2.6 Verifying that the required ECCS injection/spray subsystem can be manually started and operate for at least 10 minutes demonstrates that the subsystem is available to mitigate a draining event. Testing the ECCS injection/spray subsystem through the recirculation line is necessary to avoid overfilling the refueling cavity. The minimum operating time of 10 minutes was based on engineering judgment.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.7 Verifying that each valve credited for automatically isolating a penetration flow path actuates to the isolation position on an actual or simulated RPV water level isolation signal is required to prevent RPV water inventory from dropping below the T AF should an unexpected draining event occur.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.8 The required ECCS subsystem is required to actuate on a manual initiation signal. This Surveillance verifies that a manual initiation signal will cause the required CS subsystem or LPCI subsystem to start and operate as designed. including pump startup and actuation of all automatic valves to their required positions.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
REFERENCES This SR is modified by a Note that excludes vessel injection/spray during the Surveillance. Since all active components are testable and full flow can be demonstrated by recirculation through the test line, coolant injection into the RPV is not required during the Surveillance.
- 1. Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup,"
November 1984.
- 2. Information Notice 86-74. "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves." August 1986.
- 3. Generic Letter 92-04, "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10 CFR 50.54(Q, "August 1992.
- 4. NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs," May 1993.
- 5. Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1," July 1994.
- 6. General Electric Service Information Letter No. 388, "RHR Valve Misalignment During Shutdown Cooling Operation for BWR 3/4/5/6,"
February 1983. FSAR, Section 6.3.2.
- 2.
Final Policy Statement on Technical Specif-ications Improvements, July 22, 1993 (58 FR 39132).
(continued)
SUSQUEHANNA - UNIT 1 B 3.5-24 Revision G
B 3.5 B 3.5.3 BASES RCIC System B 3.5.3 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM RCIC System BACKGROUND The RCIC System is not part of the ECCS; however, the RCIC System is included with the ECCS section because of their similar functions.
The RCIC System is designed to operate either automatically or manually following reactor pressure vessel (RPV) isolation accompanied by a loss of coolant flow from the feedwater system to provide adequate core cooling and control of the RPV water level. Under these conditions, the High Pressure Coolant Injection (HPCI) and RCIC systems perform similar functions. The RCIC System design requirements ensure that the criteria of Reference 1 are satisfied.
The RCIC System (Ref. 2) consists of a steam driven turbine pump unit, piping, and valves to provide steam to the turbine, as well as piping and valves to transfer water from the suction source to the core via the feedwater system line, where the coolant is distributed within the RPV through the feedwater sparger. Suction piping is provided from the condensate storage tank (CST) and the suppression pool. Pump suction is normally aligned to the CST to minimize injection of suppression pool water into the RPV. However, if the CST water supply is low, an automatic transfer to the suppression pool water source ensures an adequate suction head for the pump and an uninterrupted water supply for continuous operation of the RCIC System. The steam supply to the turbine is piped from a main steam line upstream of the associated inboard main steam line isolation valve.
The RCIC System is designed to provide core cooling for a wide range of reactor pressures (165 psia to 1225 psia). Upon receipt of an initiation signal, the RCIC turbine accelerates to a specified speed. As the RCIC flow increases, the turbine control valve is automatically adjusted to maintain design flow. Exhaust steam from the RCIC turbine is discharged to the suppression pool. A full flow test line is provided to route water to the CST to allow testing of the RCIC System during normal operation without injecting water into the RPV.
(continued)
SUSQUEHANNA - UNIT 1 TS I B 3.5-25 Revision BASES BACKGROUND (continued)
APPLICABLE SAFETY ANALSES LCO APPLICABILITY ACTIONS RCIC System B 3.5.3 The RCIC pump is provided with a minimum flow bypass line, which discharges to the suppression pool. The valve in this line automatically opens to prevent pump damage due to overheating when other discharge line valves are closed. To ensure rapid delivery of water to the RPV and to minimize water hammer effects, the RCIC System discharge piping is kept full of water. The RCIC System is normally aligned to the CST. The RCIC discharge line is kept full of water using a "keep fill" system supplied by the condensate transfer system.
The function of the RCIC System is to respond to transient events by providing makeup coolant to the reactor. The RCIC System is not an Engineered Safety Feature System and no credit is taken in the safety analyses for RCIC System operation. Based on its contribution to the reduction of overall plant risk, however, the system is included in the Technical Specifications, as required by the NRC Policy Statement (Ref. 4).
The OPERABILITY of the RCIC System provides adequate core cooling such that actuation of any of the low pressure ECCS subsystems is not required in the even of RPV isolation accompanied by a loss of feedwater flow. The RCIC System has sufficient capacity for maintaining RPV inventory during an isolation event.
The RCIC System is required to be OPERABLE during MODE 1, and MODES 2 and 3 with reactor steam dome pressure > 150 psig, since RCIC is the primary non-ECCS water source for core cooling when the reactor is isolated and pressurized. In MODES 2 and 3 with reactor steam dome pressure :::;; 150 psig, the low pressure ECCS injection/spray subsystems can provide sufficient flow to the RPV. lnaRG--iR MODES 4 and 5, RCIC is not required to be OPERABLE since RPV water inventory control is required by LCO 3.5.2, "Reactor Pressure Vessel (RPV) Water Level Inventory Control."the low pressure EGGS injection/spray subsystems can provide sufficient flow to the RPV.
A Note prohibits the application of LCO 3.0.4.b to an inoperable RCIC system. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable RCIC system and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
(continued)
SUSQUEHANNA - UNIT 1 B 3.5-26 Revision.J
BASES SURVEILLANCE REQUIREMENTS REFERENCES SR 3.5.3.5 RCIC System B 3.5.3 The RCIC System is required to actuate automatically in order to verify its design function satisfactorily. This Surveillance verifies that, with a required system initiation signal (actual or simulated), the automatic initiation logic of the RCIC System will cause the system to operate as designed, including actuation of the system throughout its emergency operating sequence; that is, automatic pump startup and actuation of all automatic valves to their required positions. This test also ensures the RCIC System will automatically restart on an RPV low water level (Level 2) signal received subsequent to an RPV high water level (Level 8) trip and that the suction is automatically transferred from the CST to the suppression pool. The LOGIC SYSTEM FUNCTIONAL TEST performed in LCO 3.3.5.2-l_overlaps this Surveillance to provide complete testing of the assumed safety function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
This SR is modified by a Note that excludes vessel injection during the Surveillance. Since all active components are testable and full flow can be demonstrated by recirculation through the test line, coolant injection into the RPV is not required during the Surveillance.
- 1.
10 CFR 50, Appendix A, GDC 33.
- 2.
FSAR, Section 5.4.6.
(continued)
SUSQUEHANNA - UNIT 1 B 3.5-30 Revision BASES APPLICABLE SAFETY ANALYSES SUSQUEHANNA - UNIT 1 PC IVs B 3.6.1.3 The PCIVs LCO was derived from the assumptions related to minimizing the loss of reactor coolant inventory, and establishing the primary containment boundary during major accidents. As part of the primary containment boundary, PCIV OPERABILITY supports leak tightness of primary containment. Therefore, the safety analysis of any event requiring isolation of primary containment is applicable to this LCO.
The DBAs that result in a release of radioactive material within primary containment are a LOCA and a main steam line break (MSLB). In the analysis for each of these accidents, it is assumed that PC IVs are either closed or close within the required isolation times following event initiation. This ensures that potential paths to the environment through PCIVs (including primary containment purge valves) and secondary containment bypass valves that are not PCIVs are minimized. The closure time of the main steam isolation valves (MS IVs) for a MSLB outside primary containment is a significant variable from a radiological standpoint. The MSIVs are required to close within 3 to 5 seconds since the 5 second closure time is assumed in the analysis. The safety analyses assume that the purge valves were closed at event initiation.
Likewise, it is assumed that the primary containment is isolated such that release of fission products to the environment is controlled.
The OBA analysis assumes that within the required isolation time leakage is terminated, except for the maximum allowable leakage rate, La.
The single failure criterion required to be imposed in the conduct of unit safety analyses was considered in the original design of the primary containment purge valves. Two valves in series on each purge line provide assurance that both the supply and exhaust lines could be isolated even if a single failure occurred.
The primary containment purge valves may be unable to close in the environment following a LOCA. Therefore, each *of the purge valves is required to remain closed during MODES 1, 2, and 3 except as permitted under the Note of SR 3.6.1.3.1. In this case, the single failure criterion remains applicable to the primary containment purge valve (continued)
B 3.6-16 Revision 2
BASES LCO (continued)
APPLICABILITY PC I Vs B 3.6.1.3 The normally closed PCIVs, including secondary containment bypass valves listed in Table B 3.6.1.3-2 that are not PCIVs, are considered OPERABLE when manual valves are closed or open in accordance with appropriate administrative controls, automatic valves are in their closed position, blind flanges are in place, and closed systems are intact. These passive isolation valves and devices are those listed in Table B 3.6.1.3-1.
Leak rate testing of the secondary containment bypass valves listed in Table 3.6.1.3-2 is permitted in Modes 1, 2 & 3 as described in the Primary Containment Leakage Rate Testing Program.
Purge valves with resilient seals, secondary containment bypass valves, including secondary containment bypass valves listed in Table B 3.6.1.3-2 that are not PCIVs, MSIVs, and hydrostatically tested valves must meet additional leakage rate requirements. Other PCIV leakage rates are addressed by LCO 3.6.1.1, "Primary Containment," as Type B or C testing.
This LCO provides assurance that the PCIVs will perform their designed safety functions to minimize the loss of reactor coolant inventory and establish the primary containment boundary during accidents In MODES 1, 2, and 3, a OBA could cause a release of radioactive material to primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations of these MODES. Therefore, mast-PC I Vs are not required to be (continued)
SUSQUEHANNA - UNIT 1 B 3.6-1 ?a Revision BASES APPLICABILITY (continued)
ACTIONS SUSQUEHANNA - UNIT 1 PC IVs B 3.6.1.3 OPERABLE and the primary containment purge valves are not required to be closed in MODES 4 and 5. Certain valves, however, are required to be OPERABLE to prevent inadvertent reactor vessel draindown. These valves are those whose associated instrumentation is required to be OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."
(This does not include the valves that isolate the associated instrumentation.)
The ACTIONS are modified by a Note allowing penetration flow path(s) to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator at the controls of the valve, who is in continuous communication with the control room. In this way, the penetration can be rapidly isolated when a need for primary containment isolation is indicated.
A second Note has been added to provide clarification that, for the purpose of this LCO, separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable PCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable PCIVs are governed by subsequent Condition entry and application of associated Required Actions.
The ACTIONS are modified by Notes 3 and 4. Note 3 ensures that appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable PCIV (e.g., an Emergency Core Cooling System subsystem is inoperable due to a failed open test return valve). Note 4 ensures appropriate remedial actions are taken when the primary containment leakage limits are exceeded. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, Notes 3 and 4 are added to require the proper actions be taken.
A.1 and A.2 With one or more penetration flow paths with one PCIV inoperable except for purge valve leakage not within limit, (continued)
B 3.6-18 Revision G
BASES ACTIONS SUSQUEHANNA - UNIT 1 D.1 and D.2 (continued)
PC IVs B 3.6.1.3 Condition D is modified by a Note indicating that this Condition is only applicable to the H20 2 Analyzer penetrations.
With the secondary containment bypass leakage rate not within limit, the assumptions of the safety analysis may not be met.
Therefore, the leakage must be restored to within limit within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Restoration can be accomplished by isolating the penetration that caused the limit to be exceeded by use of one closed and de-activated automatic valve, closed manual valve, or blind flange. When a penetration is isolated, the leakage rate for the isolated penetration is assumed to be the actual pathway leakage through the isolation device. If two isolation devices are used to isolate the penetration, the leakage rate is assumed to be the lesser actual pathway leakage of the two devices. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable considering the time required to restore the leakage by isolating the penetration and the relative importance of secondary containment bypass leakage to the overall containment function.
Ll In the event one or more containment purge valves are not within the purge valve leakage limits, purge valve leakage must be restored to within limits. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time is reasonable, considering that one containment purge valve remains closed, except as controlled by SR 3.6.1.3.1 so that a gross breach of containment does not exist.
G.1 and G.2 If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued)
B 3.6-22a Revision G
BASES ACTIONS (continued)
SURVEILLANCE REQUIREMENTS SUSQUEHANNA - UNIT 1 H.1 and H.2 PC I Vs B 3.6.1.3 If any Required Action and associated Completion Time cannot be met, the unit must be placed in a condition in which the LCO does not apply. If applicable, action must be immediately initiated to suspend operations with a potential for draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindo*Nn and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended or valve(s) are restored to OPERABLE status. If suspending an OPDRV would result in closing the residual heat removal (RHR) shutdown cooling isolation valves, an alternative Required Action is provided to immediately initiate action to restore the valve(s) to OPERABLE status. This allows RHR to remain in service while actions are being taken to restore the valve.
SR 3.6.1.3.1 This SR ensures that the primary containment purge valves are closed as required or, if open, open for an allowable reason. If a purge valve is open in violation of this SR, the valve is considered inoperable. If the inoperable valve is not otherwise known to have excessive leakage when closed, it is not considered to have leakage outside of limits. The SR is also modified by Note 1, stating that primary containment purge valves are only required to be closed in MODES 1, 2, and 3. If a LOCA inside primary containment occurs in tl=!ese--MODES 1. 2, or 3, the purge valves may not be capable of closing before the pressure pulse affects systems downstream of the purge valves, or the release of radioactive material will exceed limits prior to the purge valves closing. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel),
pressurization concerns are not present and the purge valves are allowed to be open. The SR is modified by §..Note--2 stating that the SR is not required to be met when the purge valves are open for the stated reasons. The Note states that these valves may be opened for inerting, de-inerting, pressure control, ALARA or air quality considerations for personnel entry, or Surveillances that require the valves to be open. The vent and purge valves are capable of closing in the environment following a LOCA.
Therefore, these valves are allowed to be open for (continued)
B 3.6-23 Revision BASES SURVEILLANCE REQUIREMENTS SUSQUEHANNA - UNIT 1 SR 3.6.1.3.5 (continued)
PC I Vs B 3.6.1.3 full closure isolation time is demonstrated by SR 3.6.1.3.7. The isolation time test ensures that the valve will isolate in a time period less than or equal to that assumed in the Final Safety Analyses Report. The isolation time and Frequency of this SR are in accordance with the requirements of the lnservice Testing Program.
SR 3.6.1.3.6 For primary containment purge valves with resilient seals, the Appendix J Leakage Rate Test Interval of 24 months is sufficient.
The acceptance criteria for these valves is defined in the Primary Containment Leakage Rate Testing Program, 5.5.12.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The SR is modified by a Note stating that the primary containment purge valves are only required to meet leakage rate testing requirements in MODES 1, 2, and 3. If a LOCA inside primary containment occurs in #lese-MODES 1, 2 or 3, purge valve leakage must be minimized to ensure offsite radiological release is within limits. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel),
pressurization concerns are not present and the purge valves are not required to meet any specific leakage criteria.
SR 3.6.1.3.7 Verifying that the isolation time of each MSIV is within the specified limits is required to demonstrate OPERABILITY. The isolation time test ensures that the MSIV will isolate in a time period that does not exceed the times assumed in the OBA analyses. This ensures that the calculated radiological consequences of these events remain within regulatory limits. The Frequency of this SR is in accordance with the requirements of the lnservice Testing Program.
(continued)
B 3.6-26 Revision J
BASES SURVEILLANCE REQUIREMENTS (continued)
SR 3.6.1.3.10 PC I Vs B 3.6.1.3 The TIP shear isolation valves are actuated by explosive charges. An in place functional test is not possible with this design. The explosive squib is removed and tested to provide assurance that the valves will actuate when required. The replacement charge for the explosive squib shall be from the same manufactured batch as the one fired or from another batch that has been certified by having one of the batch successfully fired. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.6.1.3.11 This SR ensures that the leakage rate of secondary containment bypass leakage paths is less than the specified leakage rate. This provides assurance that the assumptions in the radiological evaluations of Reference 4 are met. The secondary containment leakage pathways and Frequency are defined by the Primary Containment Leakage Rate Testing Program. This SR simply imposes additional acceptance criteria.
A note is added to this SR, which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the other MODES other than 1, 2, or 3, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required.
SR 3.6.1.3.12 The analyses in References 1 and 4 are based on the specified leakage rate. Leakage through each MSIV must be :::; 100 scfh for any one MSIV and :::; 300 scfh for total leakage through the MS I Vs combined with the Main Steam Line Drain Isolation Valve, HPCI Steam Supply Isolation Valve and the RCIC Steam Supply Isolation Valve. The MSIVs can be tested at either~ Pt (24.3 psig) or Pa (48.6 psig). Main Steam Line Drain Isolation, HPCI and RCIC Steam Supply Line Isolation Valves, are tested at Pa (48.6 psig). A note is added to this SR, which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3.
In the other conditionsMODES other than 1, 2, or 3, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required. The Frequency is required by the Primary Containment Leakage Rate Testing Program.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-28 Revision 8
BASES SURVEILLANCE REQUIREMENTS (continued)
REFERENCES SUSQUEHANNA - UNIT 1 SR 3.6.1.3.13 PC IVs B 3.6.1.3 Surveillance of hydrostatically tested lines provides assurance that the calculation assumptions of Reference 2 are met. The acceptance criteria for the combined leakage of all hydrostatically tested lines is 3.3 gpm when tested at 1.1 Pa, (53.46 psig). The combined leakage rates must be demonstrated in accordance with the leakage rate test Frequency required by the Primary Containment Leakage Testing Program.
As noted in Table B 3.6.1.3-1, PCIVs associated with this SR are not Type C tested. Containment bypass leakage is prevented since the line terminates below the minimum water level in the Suppression Chamber. These valves are tested in accordance with the IST Program. Therefore, these valves leakage is not included as containment leakage.
This SR has been modified by a Note that states that these valves are only required to meet the combined leakage rate in MODES 1, 2, and 3, since this is when the Reactor Coolant System is pressurized and primary containment is required. In some instances, the valves are required to be capable of automatically closing during MODES other than MODES 1, 2, and 3. However, specific leakage limits are not applicable in these other MODES or conditions.
- 1.
FSAR, Chapter 15.
- 2.
Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
- 3.
10 CFR 50, Appendix J, Option B.
- 4.
FSAR, Section 6.2.
- 5.
NED0-30851 -P-A, "Technical Specification Improvement Analyses for BWR Reactor Protection System,"
March 1988.
- 6.
Standard Review Plan 6.2.4, Rev. 1, September 1975
- 7.
NED0-32977-A, "Excess Flow Check Valve Testing Relaxation," June 2000.
B 3.6-29 Revision 2
BASES (continued)
APPLICABLE SAFETY ANALYSES LCO APPLICABILITY ACTIONS Suppression Pool Water Level B 3.6.2.2 Initial suppression pool water level affects suppression pool temperature response calculations, calculated drywell pressure during vent clearing for a OBA, calculated pool swell loads for a OBA LOCA, and calculated loads due to S/RV discharges. Suppression pool water level must be maintained within the limits specified so that the safety analysis of Reference 1 remains valid.
Suppression pool water level satisfies Criteria 2 and 3 of the NRC Policy Statement. (Ref. 2)
A limit that suppression pool water level be 2 22 ft 0 inches and
$ 24 ft 0 inches is required to ensure that the primary containment conditions assumed for the safety analyses are met. Either the high or low water level limits were used in the safety analyses, depending upon which is more conservative for a particular calculation.
In MODES 1, 2, and 3, a OBA would cause significant loads on the primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES. The requirements for maintaining suppression pool water level within limits in MODE 4 or 5 is addressed in LCO 3.5.2, "EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control."
With suppression pool water level outside the limits, the conditions assumed for the safety analyses are not met. If water level is below the minimum level, the pressure suppression function still exists as long as downcomers are covered, HPCI and RCIC turbine exhausts are covered, and S/RV quenchers are covered. If suppression pool water level is above the maximum level, protection against overpressurization still exists due to the margin in the peak containment pressure analysis and the capability of the Drywell Spray System. Therefore, continued operation for a (continued)
SUSQUEHANNA - UNIT 1 B 3.6-60 Revision G
BASES (continued)
APPLICABILITY Secondary Containment B 3.6.4.1 In MODES 1, 2, and 3, a LOCA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, secondary containment OPERABILITY is required during the same operating conditions that require primary containment OPERABILITY.
In MODES 4 and 5, the probability and consequences of the LOCA are reduced due to the pressure and temperature limitations in these MODES.
Therefore, maintaining secondary containment OPERABLE is not required in MODE 4 or 5 to ensure a control volume, except for other situations for which significant releases of radioactive material can be postulated, such as during operations with a potential for draining the reactor vessel (OPDRVs), during CORE AL TERA TIONS, or during movement of irradiated fuel assemblies in the secondary containment.
ACTIONS A.1 If secondary containment is inoperable, it must be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining secondary containment during MODES 1, 2, and 3. This time period also ensures that the probability of an accident (requiring secondary containment OPERABILITY) occurring during periods where secondary containment is inoperable is minimal.
A temporary (one time) Completion Time is connected to the Completion Time Requirements above (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />) with an "OR" connector. The Temporary Completion Time is 4 B hours and applies to the replacement of the Reactor Building Recirculating Fan Damper Motors. The Temporary Completion Time of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> may only be used once, and expires on December 31,
200§.,.
B.1 and B.2 If secondary containment cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-86 Revision 4
BASES ACTIONS (continued)
C.1 and, C.2, and C.3 Secondary Containment B 3.6.4.1 Movement of irradiated fuel assemblies in the secondary containment, and CORE AL TERA TIONS, and OPDRVs can be postulated to cause fission product release to the secondary containment. In such cases, the secondary containment is the only barrier to release of fission products to the environment. CORE AL TE RATIONS and movement of irradiated fuel assemblies must be immediately suspended if the secondary containment is inoperable.
Suspension of these activities shall not preclude completing an action that involves moving a component to a safe position. Also, action must be immediately initiated to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release.
Actions must continue until OPDRVs are suspended.
Required Action C.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.1.1 REQUIREMENTS This SR ensures that the secondary containment boundary is sufficiently leak tight to preclude exfiltration under expected wind conditions.
Expected wind conditions are defined as sustained wind speeds of less than or equal to 16 mph at the 60m meteorological tower or less than or equal to 11 mph at the 1 Om meteorological tower if the 60m tower wind speed is not available. Changes in indicated reactor building differential pressure observed during periods of short-term wind speed gusts above these sustained speeds do not by themselves impact secondary containment integrity. However, if secondary containment integrity is known to be compromised, the LCO must be entered regardless of wind speed.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-87 Revision 2
SC IVs B 3.6.4.2 BASES (continued)
APPLICABILITY In MODES 1, 2, and 3, a OBA could lead to a fission product release to the primary containment that leaks to the secondary containment. Therefore, the OPERABILITY of SCIVs is required.
ACTIONS In MODES 4 and 5, the probability and consequences of these events are reduced due to pressure and temperature limitations in these MODES.
Therefore, maintaining SCIVs OPERABLE is not required in MODE 4 or 5, except for other situations under which significant radioactive releases can be postulated, such as during operations with a potential for draining the reactor vessel (OPDRVs), during CORE ALTERATIONS, or during movement of irradiated fuel assemblies in the secondary containment. Moving irradiated fuel assemblies in the secondary containment may also occur in MODES 1, 2, and 3.
The ACTIONS are modified by three Notes. The first Note allows penetration flow paths to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator, who is in continuous communication with the control room, at the controls of the isolation device.
In this way, the penetration can be rapidly isolated when a need for secondary containment isolation is indicated.
The second Note provides clarification that for the purpose of this LCO separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable SCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable SCIVs are governed by subsequent Condition entry and application of associated Required Actions.
The third Note ensures appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable SCIV.
A.1 and A.2 In the event that there are one or more required penetration flow paths with one required SCIV inoperable, the affected penetration flow path(s) must be isolated. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic SCIV, a closed manual valve, and a blind flange. For penetrations isolated in (continued)
SUSQUEHANNA - UNIT 1 B 3.6-93 Revision~
BASES ACTIONS C.1 and C.2 (continued)
SCI Vs B 3.6.4.2 valves are operated under administrative controls and the probability of their misalignment is low.
Condition C is modified by a Note indicating that this Condition is only applicable to penetration flow paths with only one SCIV. For penetration flow paths with two SCIVs, Conditions A and B provide the appropriate Required Actions.
Required Action C.2 is modified by a Note that applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative means. Allowing verification by administrative means is considered acceptable, since access to these areas is typically restricted.
Therefore, the probability of misalignment of these valves, once they have been verified to be in the proper position, is low.
D.1 and D.2 If any Required Action and associated Completion Time cannot be met, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
E.1 and, E.2. and E.3 If any Required Action and associated Completion Time are not met, the plant must be placed in a condition in which the LCO does not apply. If applicable, CORE AL TE RATIONS and the movement of irradiated fuel assemblies in the secondary containment must be immediately suspended. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be immediately initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and the subsequent potential f.or f.ission product release. Actions must continue until OPDRVs are suspended.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-96 Revision 4
BASES ACTIONS E.1, and E.2, and E.3 (continued)
SCI Vs B 3.6.4.2 Required Action E.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving fuel while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.2.1 REQUIREMENTS This SR verifies that each secondary containment manual isolation valve and blind flange that is required to be closed during accident conditions is closed.
The SR helps to ensure that post accident leakage of radioactive fluids or gases outside of the secondary containment boundary is within design limits.
This SR does not require any testing or valve manipulation. Rather, it involves verification (typically visual) that those required SCIVs in secondary containment that are capable of being mispositioned are in the correct position.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
Two Notes have been added to this SR. The first Note applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative controls. Allowing verification by administrative controls is considered acceptable, since access to these areas is typically restricted during MODES 1, 2, and 3 for ALARA reasons. Therefore, the probability of misalignment of these SCIVs, once they have been verified to be in the proper position, is low.
A second Note has been included to clarify that SCIVs that are open under administrative controls are not required to meet the SR during the time the SCIVs are open.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-97 Revision tl
BASES LCO (continued)
APPLICABILITY SGT System B 3.6.4.3 one SGT subsystem in the event of a single active failure. A SGT subsystem is considered OPERABLE when it has an OPERABLE set of dampers, filter train, one reactor building recirculation fan and associated dampers, and associated controls, including instrumentation. (The reactor building recirculation fans and associated dampers are not dedicated to either SGT subsystem. As a result, when any one reactor building recirculation division is not OPERABLE, one arbitrarily determined SGT subsystem is not operable. This interpretation only applies if both divisions of Secondary Containment Isolation logic are operable). This includes the components required for at least one of the two SGTS filter cooling modes.
In MODES 1, 2, and 3, a OBA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, SGT System OPERABILITY is required during these MODES.
In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES.
Therefore, maintaining the SGT System in OPERABLE status is not required in MODE 4 or 5, except for other situations under which significant releases of radioactive material can be postulated, such as during operations with a potential for draining the reactor vessel (OPDRVs), during CORE AL TERA TIONS, or during movement of irradiated fuel assemblies in the secondary containment.
ACTIONS A.1 With one SGT subsystem inoperable, the inoperable subsystem must be restored to OPERABLE status in 7 days. In this Condition, the remaining OPERABLE SGT subsystem is adequate to perform the required radioactivity release control function. However, the overall system reliability is reduced because a single failure in the OPERABLE subsystem could result in the radioactivity release control function not being adequately performed. The 7 day Completion Time is based on consideration of such factors as the availability of the OPERABLE redundant SGT System and the low probability of a OBA occurring during this period.
(continued)
SUSQUEHANNA-UNIT 1 B3.6-103 Revision~
BASES ACTIONS (continued)
B.1 and B.2 SGT System B 3.6.4.3 If the SGT subsystem cannot be restored to OPERABLE status within the required Completion Time in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
C.1, C.2.1, and C.2.2, and C.2.3 During movement of irradiated fuel assemblies, in the secondary containment_Q[, during CORE AL TERA TIONS, or during OPDRVs, when Required Action A.1 cannot be completed within the required Completion Time, the OPERABLE SGT filter train should immediately be placed in operation. This action ensures that the remaining filter train is OPERABLE, that no failures that could prevent automatic actuation have occurred, and that any other failure would be readily detected.
An alternative to Required Action C.1 is to immediately suspend activities that represent a potential for releasing radioactive material to the secondary containment, thus placing the plant in a condition that minimizes risk. If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies must immediately be suspended. Suspension of these activities must not preclude completion of movement of a component to a safe position. Also, if applicable, actions must immediately be initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
The Required Actions of Condition C have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-104 Revision~
BASES SGT System B 3.6.4.3 ACTIONS D.1 (continued)
If both SGT subsystems are inoperable in MODE 1, 2, or 3, the SGT system may not be capable of supporting the required radioactivity release control function. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining the SGT System contribution to secondary containment during MODES 1, 2, and 3. This time period also ensures that the probability of an accident (requiring SGT OPERABILITY) occurring during periods where SGT is inoperable is minimal.
A temporary (one time) Completion Time is connected to the Completion Time Requirements above (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />) with an "OR" connector. The Temporary Completion Time is 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and applies to the replacement of the Reactor Building Recirculating Fan Damper Motors. The Temporary Completion Time of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> may only be used once, and expires on December 31, 2005.
E.1 and E.2 If at least one SGT subsystem cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.
The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
F.1 and, F.2, and F.3 When two SGT subsystems are inoperable, if applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in secondary containment must immediately be suspended. Suspension of these activities shall not preclude completion of movement of a component to a safe position.,l\\lso, if applicable, actions must immediately be initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-105 Revision~
BASES ACTIONS F.17 and F.2. and F.3 (continued)
SGT System B 3.6.4.3 Required Action F.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.3.1 REQUIREMENTS Operating each SGT filter train for :?: 15 continuous minutes with heaters on ensures that both filter train are OPERABLE and that all associated controls are functioning properly. It also ensures that blockage, fan or motor failure, or excessive vibration can be detected for corrective action.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.6.4.3.2 This SR verifies that the required SGT filter testing is performed in accordance with the Ventilation Filter Testing Program (VFTP). The VFTP includes testing HEPA filter performance, charcoal adsorber efficiency, minimum system flow rate, and the physical properties of the activated charcoal (general use and following specific operations). Specific test frequencies and additional information are discussed in detail in the VFTP.
SR 3.6.4.3.3 This SR verifies that each SGT subsystem starts on receipt of an actual or simulated initiation signal. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
(continued)
SUSQUEHANNA - UNIT 1 B 3.6-106 Revision J
BASES LCO (continued)
APPLICABILITY CREOAS System B 3.7.3 The LCO is modified by a Note allowing the CRE boundary to be opened intermittently under administrative controls. This Note only applies to openings in the CRE boundary that can be rapidly restored to the design condition, such as doors, hatches, floor plugs, and access panels. For entry and exit through doors the administrative control of the opening is performed by the person(s) entering or exiting the area. For other openings, these controls should be proceduralized and consist of stationing a dedicated individual at the opening who is in continuous communication with the operators in the CRE. This individual will have a method to rapidly close the opening and to restore the CRE boundary to a condition equivalent to the design condition when a need for CRE isolation is indicated.
In MODES 1, 2, and 3, the CREOAS System must be OPERABLE to ensure that the CRE will remain habitable during and following a DBA, since the DBA could lead to a fission product release.
In MODES 4 and 5, the probability and consequences of a DBA are reduced because of the pressure and temperature limitations in these MODES.
Therefore, maintaining the CREOAS System OPERABLE is not required in MODE 4 or 5, except for the follmving situations under which significant radioactive releases can be postulated:
- a. During operations with a potential for draining the reactor vessel (OPDRVs);
b.§..QGuring CORE AL TE RATION~ and cg..QGuring movement of irradiated fuel assemblies in the secondary containment.
(continued)
SUSQUEHANNA - UNIT 1 B 3.7-16 Revision 3
BASES ACTIONS (continued)
D.1. D.2.1. and D.2.2. and D.2.3 CREOAS System B 3.7.3 The Required Actions of Condition D are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require either an entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment or, during CORE AL TERA TIONS, or during OPDRVs, if the inoperable CREOAS subsystem cannot be restored to OPERABLE status within the required Completion Time, the OPERABLE CREOAS subsystem may be placed in the pressurization/filtration mode. This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent automatic actuation will occur, and that any active failure will be readily detected.
An alternative to Required Action D.1 is to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the CRE. This places the unit in a condition that minimizes the accident risk.
If applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately.
Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and the subsequent potential for fission product release. Actions must continue until the OPDRVs are suspended.
If both CREOAS subsystems are inoperable in MODE 1, 2, or 3, for reasons other than an inoperable CRE boundary (i.e., Condition B) the CREOAS System may not be capable of performing the intended function and the unit is in a condition outside of the accident analyses. Therefore, LCO 3.0.3 must be entered immediately.
(continued)
SUSQUEHANNA - UNIT 1 B 3.7-18A Revision 4-
BASES ACTIONS (continued)
SURVEILLANCE REQUIREMENTS F.1 and, F.2. and F.3 CREOAS System B 3.7.3 The Required Actions of Condition F are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require either an entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment_Q.[1 during CORE AL TERA TIONS, or during OPDRVs, with two CREOAS subsystems inoperable or with one or more CREOAS subsystems inoperable due to an inoperable CRE boundary, action must be taken immediately to suspend activities that present a potential for releasing radioactivity that might require pressurization of the CRE. This places the unit in a condition that minimizes the accident risk.
If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately Suspension of these activities shall not preclude completion of movement of a component to a safe position. If applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential f.or fission product release. Actions must continue until the OPDRVs are suspended.
SR 3.7.3.1 This SR verifies that a CREOAS fan in a standby mode starts on demand from the control room and continues to operate with flow through the HEPA filters and charcoal adsorbers. Standby systems should be checked periodically to ensure that they start and function properly. As the environmental and normal operating conditions of this system are not severe, testing each subsystem once every month provides an adequate check on this system. Systems with heaters must be operated for ;;::: 15 continuous minutes with the heaters energized. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
(continued)
SUSQUEHANNA - UNIT 1 B 3.7-188 Revision BASES APPLICABLE SAFETY ANALYSES (continued)
LCO APPLICABILITY Control Room Floor Cooling System B 3.7.4 The Control Room Floor Cooling System satisfies Criterion 3 of the NRC Policy Statement. (Ref. 2)
Two independent and redundant subsystems of the Control Room Floor Cooling System are required to be OPERABLE to ensure that at least one is available, assuming a single failure disables the other subsystem. Total system failure could result in the equipment operating temperature exceeding limits.
The Control Room Floor Cooling System is considered OPERABLE when the individual components necessary to maintain the control room temperature are OPERABLE in both subsystems. These components include the cooling coils, fans, chillers, compressors, ductwork, dampers, and associated instrumentation and controls. The Control Room Floor Cooling System fans, ductwork, and dampers are also addressed by LCO 3.7.3, "Control Room Emergency Outside Air Supply System".
In MODE 1, 2, or 3, the Control Room Floor Cooling System must be OPERABLE to ensure that the control room temperature will not exceed equipment OPERABILITY limits following habitability envelope isolation.
In MODES 4 and 5, the probability and consequences of a Design Basis Accident are reduced due to the pressure and temperature limitations in these MODES. Therefore, maintaining the Control Room Floor Cooling System OPERABLE is not required in MODE 4 or 5, except f.or the f.ollowing situations under which significant radioactive releases can be postulated:
- a. During operations with a potential f.or draining the reactor *,iessel (OPDRVs);
~g uring CORE AL TERA TIONS,. and
~g uring movement of irradiated fuel assemblies in the secondary containment.
ACTIONS A.1 (continued)
SUSQUEHANNA - UNIT 1 B 3.7-20 Revision 4
BASES Control Room Floor Cooling System B 3.7.4 With one control room floor cooling subsystem inoperable, the inoperable control room floor cooling subsystem must be restored to OPERABLE status within 30 days. With the unit in this condition, the remaining OPERABLE control room floor cooling subsystem is adequate to perform the control room air conditioning function. However, the overall reliability is reduced because a single failure in the OPERABLE subsystem could result in loss of the control room air conditioning function. The 30 day Completion Time is based on the low probability of an event occurring requiring habitability envelope isolation, the consideration that the remaining subsystem can provide the required protection, and the availability of alternate safety and nonsafety cooling methods. Since nonsafety alternate cooling methods are available, this Action is less restrictive than 3.7.3 where an alternate method of maintaining the habitability envelope at a positive pressure is not available.
B.1 and B.2 In MODE 1, 2, or 3, if the inoperable control room floor cooling subsystem cannot be restored to OPERABLE status within the associated Completion Time, the unit must be placed in a MODE that minimizes risk. To achieve this status, the unit must be placed in at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
C.1. C.2. 1. and C.2.2, and C.2.3 The Required Actions of Condition C are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment or, during CORE AL TERA TIONS, or during OPDRVs, if Required Action A.1 cannot be completed within the required Completion Time, the OPERABLE control room floor cooling subsystem may be placed immediately in operation. This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent actuation will occur, and that any active failure will be readily detected.
(continued)
SUSQUEHANNA - UNIT 1 B 3.7-21 Revision-+
BASES ACTIONS Control Room Floor Cooling System B 3.7.4 C.1, C.2.1. and C.2.2. and C.2.3 (continued)
An alternative to Required Action C.1 is to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the habitability envelope. This places the unit in a condition that minimizes risk.
If applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately.
Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until the OPDRVs are suspended.
If both control room floor cooling subsystems are inoperable in MODE 1, 2, or 3, the Control Room Floor Cooling System may not be capable of performing the intended function. Therefore, LCO 3.0.3 must be entered immediately.
E.1 and. E.2. and E.3 The Required Actions of Condition E are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
Therefore, inability to suspend movement of irradiated fuel assemblies is not a sufficient reason to require entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment or, during CORE AL TERA TIONS, or during OPDRVs, with two control room floor cooling subsystems inoperable, action must be taken immediately to suspend activities that present a potential for releasing radioactivity that might require isolation of the habitability envelope. This places the unit in a condition that minimizes risk.
If applicable, CORE ALTERATIONS and handling of irradiated fuel in the secondary containment must be suspended immediately.
Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately (continued)
SUSQUEHANNA - UNIT 1 B 3.7-22 Revision 4-
BASES ACTIONS E.1 and, E.2, and E.3 (continued)
Control Room Floor Cooling System B 3.7.4 to suspend OPDRVs to minimize the probability of a vessel draindovm and subsequent potential for fission product release. Actions must continue until the OPDRVs are suspended.
SURVEILLANCE SR 3.7.4.1 REQUIREMENTS REFERENCES This SR verifies that the heat removal capability of the system is sufficient to remove the control room heat load assumed in the safety analyses. The SR consists of a combination of testing and calculation. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
- 1. FSAR, Section 6.4.
- 2. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
SUSQUEHANNA - UNIT 1 B 3.7-23 Revision~
AC Sources-Shutdown B 3.8.2 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.2 AC Sources-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the AC sources is provided in the Bases for LCO 3.8.1, "AC Sources-Operating."
The OPERABILITY of the minimum AC sources during MODES 4 and 5 and during movement of irradiated fuel assemblies ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate AC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindo*Nn of the vessel or a fuel handling accident.
In general, when the unit is shut down the Technical Specifications requirements ensure that the unit has the capability to mitigate the consequences of postulated accidents. However, assuming a single failure and concurrent loss of all offsite or loss of all onsite power is not required. The rationale for this is based on the fact that many Design Basis Accidents (DBAs) that are analyzed in MODES 1, 2, and 3 have no specific analyses in MODES 4 and 5. Worst case bounding events are deemed not credible in MODES 4 and 5 because the energy contained within the reactor pressure boundary, reactor coolant temperature and pressure, and corresponding stresses result in the probabilities of occurrences significantly reduced or eliminated, and minimal consequences. These deviations from OBA analysis assumptions and design requirements during shutdown conditions are allowed by the LCO for required systems.
The Safety Analysis for Unit 2 assumes the OPERABILITY of some equipment that receives power from Unit 1 AC Sources.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-38 Revision G
BASES (continued)
AC Sources-Shutdown B 3.8.2 LCO One offsite circuit capable of supplying the onsite Class 1 E power distribution subsystem(s) of LCO 3.8.8, "Distribution Systems-Shutdown," ensures that all required loads are powered from offsite power. An OPERABLE DG, associated with a Distribution System Engineered Safeguards System (ESS) bus required OPERABLE by LCO 3.8.8, ensures that a diverse power source is available for providing electrical power support assuming a loss of the offsite circuit. Together, OPERABILITY of the required offsite circuit and DG ensures the availability of sufficient AC sources to operate the plant in a safe manner and to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and reactor vessel draindo*.vn).
The qualified offsite circuit(s) must be capable of maintaining rated frequency and voltage while connected to their respective ESS bus( es),
and of accepting required loads during an accident. Qualified offsite circuits are those that are described in the FSAR and are part of the licensing basis for the unit. An offsite circuit includes all breakers, transformers, switches, automatic tap changers, interrupting devices, cabling, and controls required to transmit power from the offsite transmission network to the onsite Class 1 E ESS bus or buses. The offsite circuit consists of the incoming breaker and disconnect to startup transformers (ST) No. 1 O and ST No. 20 and the respective circuit path including feeder breakers to the four 4.16 kV ESS buses (A, B, C and D) for both Unit 1 and Unit 2. A detailed description of the offsite power network and circuits to the onsite Class 1 E ESS buses is found in the FSAR, Section 8.2.
The required DG must be capable of starting, accelerating to rated speed and voltage, connecting to its respective ESS bus on detection of bus undervoltage, and capable of accepting required loads. This sequence must be accomplished within 1 O seconds. Each DG must also be capable of accepting required loads within the assumed loading sequence intervals, and must continue to operate until offsite power can be restored to the ESS buses. These capabilities are required to be met from a variety of initial conditions such as DG in standby with engine hot. Additional DG capabilities must be demonstrated to meet required Surveillances, e.g.,
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-40 Revision G
BASES LCO (continued)
APPLICABILITY ACTIONS AC Sources-Shutdown B 3.8.2 capability of the DG to revert to standby status on an ECCS signal while operating in parallel test mode.
Proper sequencing of loads, including tripping of nonessential loads, is a required function for DG OPERABILITY. In addition, proper sequence operation is an integral part of offsite circuit OPERABILITY since its inoperability impacts the ability to start and maintain energized loads required OPERABLE by LCO 3.8.8.
The AC sources are required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment to provide assurance that:
- a.
Systems that provide core coolingproviding adequate coolant inventory makeup are available for the irradiated fuel assemblies in the core in case of an inadvertent draindo\\tm of the reactor vessel;
- b.
Systems needed to mitigate a fuel handling accident are available;
- c.
Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
AC power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.1.
The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-41 Revision Q
BASES ACTIONS (continued)
AC Sources-Shutdown B 3.8.2 With one or more required AC Sources (DGs or 4.16 kV ESS buses) inoperable, the remaining required sources may be capable of supporting sufficient required features (e.g., system, subsystem, divisions, component or device), to allow continuation of CORE AL TERA TIONS, and fuel movement, and operations 1.vith a potential f.or draining the reactor vessel. For example, if two or more 4 kV emergency buses are required per LCO 3.8.8, one 4.16 kV emergency bus with offsite power available may be capable of supporting sufficient required features.
Therefore, the option provided by Required Action A.1 to declare required features inoperable when not powered from an offsite source or not capable of being powered by the required DG recognizes that appropriate restrictions will be required by ACTIONS in the LCO for the affected feature(s).
A.2.1. and A.2.2. and A.2.3, and A2.4 With one or more required AC Sources inoperable, the option exists in ACTION A.1 to declare all affected features inoperable. Since this option may involve undesired administrative efforts, the allowance for sufficiently conservative actions is made. With one or more required AC Sources inoperable, the minimum required diversity of AC power sources is not available. It is, therefore, required to suspend CORE AL TERA TIONS and, movement of irradiated fuel assemblies in the secondary containment, and activities that could result in inadvertent draining of the reactor vessel.
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required AC sources and to continue this action until restoration is accomplished in order to provide the necessary AC power to the plant safety systems.
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required AC electrical power sources should be completed as quickly as possible in order to (continued)
SUSQUEHANNA - UNIT 1 B 3.8-42 Revision G
BASES ACTIONS SURVEILLANCE REQUIREMENTS A.2.1. and A.2.2. and A.2.3, and A.2.4 AC Sources-Shutdown B 3.8.2 (continued) minimize the time during which the plant safety systems may be without sufficient power.
Because of the allowance provided by LCO 3.0.6, the Distribution System ACTIONS would not be entered even if all AC sources to it are inoperable, resulting in de-energization. Therefore, the Required Actions of Condition A have been modified by a Note to indicate that when Condition A is entered with no AC power to any required ESS bus, ACTIONS for LCO 3.8.8 must be immediately entered. This Note allows Condition A to provide requirements for the loss of the offsite circuit whether or not a 4.16 kV ESS bus is de-energized. LCO 3.8.8 provides the appropriate restrictions for the situation involving a de-energized 4.16 kV ESS bus.
SR 3.8.2.1 SR 3.8.2.1 requires the SRs from LCO 3.8.1 that are necessary for ensuring the OPERABILITY of the AC sources in other than MODES 1, 2, and 3. SR 3.8.1.8 is not required to be met since only one offsite circuit is required to be OPERABLE. SR 3.8.1.17 is not required to be met because the required OPERABLE DG(s) is not required to undergo periods of being synchronized to the offsite circuit. SR 3.8.1.20 is excepted because starting independence is not required with the DGs that are not required to be OPERABLE. Refer to the corresponding Bases for LCO 3.8.1 for a discussion of each SR.
This SR is modified by a Note that specified SRs must be met but are not required to be performed. The reason for the Note is to preclude requiring the OPERABLE DG(s) from being paralleled with the offsite power network or otherwise rendered inoperable during the performance of SRs, and to preclude de-energizing a required 4.16 kV ESS bus or disconnecting a required offsite circuit during performance of SRs. With limited AC sources available, a single event could compromise both the required circuit and the DG.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-43 Revision 0
DC Sources-Shutdown B 3.8.5 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.5 DC Sources-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the DC sources is provided in the Bases for LCO 3.8.4, "DC Sources-Operating."
The initial conditions of Design Basis Accident and transient analyses in the FSAR, Chapter 6 (Ref. 1) and Chapter 15 (Ref. 2), assume that Engineered Safety Feature systems are OPERABLE. The DC electrical power system provides normal and emergency DC electrical power for the diesel generators (DGs), emergency auxiliaries, and control and switching during all MODES of operation.
The OPERABILITY of the DC subsystems is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum DC electrical power sources during MODES 4 and 5 and during movement of irradiated fuel assemblies ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate DC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of the vessel or a fuel handling accident.
LCO 3.8.5 is normally satisfied by maintaining the OPERABILITY of all Division I or all Division II DC sources listed in Table 3.8.4-1 and the Diesel Generator E battery bank. However, any combination of DC sources that maintain OPERABILITY of equipment required by Technical Specifications may be used to satisfy this LCO. The DC sources satisfy Criterion 3 of the NRC Policy Statement (Ref. 3).
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-66 Revision 4
BASES (continued)
LCO APPLICABILITY DC Sources-Shutdown B 3.8.5 The DC electrical power subsystems are required to be OPERABLE as needed to support required DC distribution subsystems required OPERABLE by LCO 3.8.8, "Distribution Systems-Shutdown." This requirement ensures the availability of sufficient DC electrical power sources to operate the unit in a safe manner and to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and inadvertent reactor vessel draindown).
The DC electrical power subsystems consist of the following:
a) each Unit 1 DC electrical power subsystem identified in Table 3.8.4-1 including a 125 volt or 250 volt DC battery bank in parallel with a battery charger and the corresponding control equipment and interconnecting cabling supplying power to the associated bus; and, b) the Diesel Generator E DC electrical power subsystem identified in Table 3.8.4-1 including a 125 volt DC battery bank in parallel with a battery charger and the corresponding control equipment and interconnecting cabling supplying power to the associated bus.
The DC electrical power sources required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that:
- a.
Required features to provide core coolingadequate coolant inventory makeup are available for the irradiated fuel assemblies in the core in case of an inad*1ertent draindown of the reactor vessel;
- b.
Required features needed to mitigate a fuel handling accident are available;
- c.
Required features necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
The DC electrical power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.4.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-67 Revision-+
BASES (continued)
ACTIONS DC Sources-Shutdown B 3.8.5 The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. This is acceptable because LCO 3.0.3 would not specify any additional actions while in MODE 4 or 5 and moving irradiated fuel assemblies.
A.1, A.2.1. A.2.2. and A.2.3. and 1\\.2.4 If more than one Unit 1 DC distribution subsystem is required according to LCO 3.8.8, the remaining operable Unit 1 DC subsystems may be capable of supporting sufficient required features to allow continuation of CORE AL TERA TIONS and, fuel movement, and operations 111ith a potential for draining the reactor vessel. Therefore, the option is provided to declare required features with associated DC power sources inoperable which ensures that appropriate restrictions are implemented in accordance with the affected system LCOs' ACTIONS.
In many instances, this option may involve undesired administrative efforts. Therefore, the allowance for sufficiently conservative actions is made (i.e., to suspend CORE ALTERATIONS and, movement of irradiated fuel assemblies, and any activities that could result in inadvertent draining of the reactor vessel). Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required Unit 1 DC electrical power subsystems and to continue this action until restoration is accomplished in order to provide the necessary DC electrical power to the plant safety systems.
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required DC electrical power subsystems should be completed as quickly as possible in order to minimize the time during which the plant safety systems may be without sufficient power.
Condition A is modified by a Note that states that Condition A is not applicable to the DG E DC electrical power subsystem. Condition B or C is applicable to an inoperable DG E DC electrical power subsystem.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-68 Revision-+
Distribution Systems-Shutdown B 3.8.8 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.8 Distribution Systems-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the AC and DC electrical power distribution system is provided in the Bases for LCO 3.8.7, "Distribution Systems-Operating."
The initial conditions of Design Basis Accident and transient analyses in the FSAR, Chapter 6 (Ref. 1) and Chapter 15 (Ref. 2), assume Engineered Safety Feature (ESF) systems are OPERABLE. The AC and DC electrical power distribution systems and the DG E DC electrical power distribution subsystem are designed to provide sufficient capacity, capability, redundancy, and reliability to ensure the availability of necessary power to ESF systems so that the fuel, Reactor Coolant System, and containment design limits are not exceeded.
The OPERABILITY of the AC and DC electrical power distribution system is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum AC and DC electrical power sources and associated power distribution subsystems during MODES 4 and 5, and during movement of irradiated fuel assemblies in the secondary containment ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of the vessel or a fuel handling accident.
LCO 3.8.8 is normally satisfied by maintaining the OPERABILITY of all Division I or all Division II DC distribution subsystems listed in Table 3.8.7-1 and the (continued)
SUSQUEHANNA - UNIT 1 B 3.8-86 Revision Q
BASES APPLICABLE SAFETY ANALYSES (continued)
LCO APPLICABILITY Distribution Systems-Shutdown B 3.8.8 diesel generator E distribution subsystem. However, any combination of DC distribution subsystems that maintain OPERABILITY of equipment required by Technical Specifications may be used to satisfy this LCO.
The AC and DC electrical power distribution systems satisfy Criterion 3 of the NRC Policy Statement (Ref. 3).
Various combinations of subsystems, equipment, and components are required OPERABLE by other LCOs, depending on the specific plant condition. Implicit in those requirements is the required OPERABILITY of necessary support required features. This LCO explicitly requires energization of the portions of the electrical distribution system necessary to support OPERABILITY of Technical Specifications required systems, equipment, and components-both specifically addressed by their own LCO, and implicitly required by the definition of OPERABILITY.
Maintaining these portions of the distribution system energized ensures the availability of sufficient power to operate the plant in a safe manner to mitigate the consequences of postulated events during shutdown (e.g.,
fuel handling accidents and inadvertent reactor 11essel draindown). The AC and DC electrical power distribution subsystem is only considered inoperable when the subsystem is not energized to its proper voltage.
The AC and DC electrical power distribution subsystems required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that:
- a.
Systems that provide core coolingto provide adequate coolant inventory makeup are available f-Or the irradiated fuel in the oore in ease of an inad*1ertent draindown of the reactor vessel;
- b.
Systems needed to mitigate a fuel handling accident are available; (continued)
SUSQUEHANNA-UNIT 1 B 3.8-87 Revision Q
BASES APPLICABILITY (continued)
ACTIONS Distribution Systems-Shutdown B 3.8.8
- c.
Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
The AC, DC and DG E electrical power distribution subsystem requirements for MODES 1, 2, and 3 are covered in LCO 3.8.7.
The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. This is acceptable because LCO 3.0.3 would not specify any additional Actions in MODE 4 or 5 moving irradiated fuel assemblies.
The Unit 1 AC and DC subsystems remaining OPERABLE with one or more Unit 1 AC and DC power sources inoperable may be capable of supporting sufficient required features to allow continuation of CORE AL TERA TIO NS and, fuel movement, and operations with a potential for draining the reactor vessel. Therefore, the option is provided to declare required features with associated power sources inoperable which ensures that appropriate restrictions are implemented in accordance with the affected system LCOs' ACTIONS.
Condition A is modified by a Note that states that Condition A is not applicable to the DG E DC electrical power subsystem. Condition B or C is applicable to an inoperable DG E DC electrical power subsystem.
A.2.1. A.2.2. A.2.3. and A.2.4. and A.2.5 In many instances the option above may involve undesired administrative efforts. Therefore, the allowance for sufficiently conseNative actions is made, (i.e., to suspend CORE AL TERA TIONS and, movement of irradiated fuel assemblies in the secondary containment, and any activities that could result in inadvertent draining of the reactor vessel).
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-88 Revision G
BASES ACTIONS A.2.1, A.2.2, A.2.3, and A.2.4, and A.2.5 Distribution Systems-Shutdown B 3.8.8 (continued)
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition.
These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required AC and DC electrical power distribution subsystems and to continue this action until restoration is accomplished in order to provide the necessary power to the plant safety systems.
Required Actions A.2.1 through A.2.4-~do not adequately address the concerns relating to coolant circulation and heat removal. Pursuant to LCO 3.0.6, the RHR-SDC ACTIONS would not be entered. Therefore, Required Action A.2.&1._is provided to direct declaring RHR-SDC inoperable and not in operation, which results in taking all appropriate RHR-SDC ACTIONS.
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required distribution subsystems should be completed as quickly as possible in order to minimize the time the plant safety systems may be without power.
Required Action A.2 is modified by a Note. The Note ensures that appropriate remedial actions are taken, if necessary, if a required ECCS subsystem is rendered inoperable by the inoperability of the electrical distribution subsystem. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, the Note is added to require the proper actions be taken.
If Diesel Generator E is not aligned to the class 1 E distribution system, the only supported safety function is the ESW system. Therefore, if Diesel Generator E DC power distribution subsystem is not OPERABLE, actions are taken to either restore the battery to OPERABLE status or shutdown Diesel Generator E and close the associated ESW valves to ensure the OPERABILITY of the ESW system. The 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> limit is consistent with the allowed time for other inoperable DC sources and provides sufficient time to evaluate the condition of the battery and take the corrective actions.
(continued)
SUSQUEHANNA - UNIT 1 B 3.8-89 Revision Q
BASES APPLICABLE SAFETY ANALYSES (continued)
LCO lnservice Leak and Hydrostatic Testing Operation B 3.10.1 In the unlikely event of a largeany primary system leak that could result in draining the RPV, the reactor vessel would rapidly depressurize, allowing the low pressure core cooling systems to operate. The make-up capability of the low pressure coolant injection and core spray subsystems, as required in MODE 4 by LCO 3.5.2, "EGGS ShutdownReactor Pressure Vessel (RPV)-Water Inventory Control," would be more than adequate to keep the core floodedRPV water level above the TAF under this low decay heat load condition.
Small system leaks would be detected by leakage inspections before significant inventory loss occurred.
For the purposes of this test, the protection provided by normally required MODE 4 applicable LCOs, in addition to the secondary containment requirements required to be met by this Special Operations LCO, will ensure acceptable consequences during normal hydrostatic test conditions and during postulated accident conditions.
As described in LCO 3.0.7, compliance with Special Operations LCOs is optional, and therefore, no criteria of the NRC Policy Statement apply. Special Operations LCOs provide flexibility to perform certain operations by appropriately modifying requirements of other LCOs. A discussion of the criteria satisfied for the other LCOs is provided in their respective Bases.
As described in LCO 3.0.7, compliance with this Special Operations LCO is optional. Operation at reactor coolant temperatures > 200°F but.::: 212°F can be in accordance with Table 1.1-1 for MODE 3 operation without meeting this Special Operations LCO or its ACTIONS. This option may be required due to plant conditions or PIT limits, however, which require testing at temperatures> 200°F, while the ASME inservice test itself requires the safety/relief valves to be gagged, preventing their OPERABILITY. Additionally, even with required minimum reactor coolant temperatures< 200°F, RCS temperatures may drift above 200°F during the performance of inservice leak and hydrostatic testing or during subsequent control rod scram time testing, which is typically performed in conjunction with inservice leak and hydrostatic testing. While this Special Operations LCO is provided for inservice leak and hydrostatic testing, and for scram time testing initiated in conjunction with an inservice leak or hydrostatic test, parallel performance of other tests and inspections is not precluded.
(continued)
SUSQUEHANNA - UNIT 1 B 3.10-3 Revision+
TABLE OF CONTENTS (TECHNICAL SPECIFICATIONS BASES)
B2.0 B2.1.1 B2.1.2 B3.0 B3.1 B3.1.1 B3.1.2 B3.1.3 B3.1.4 B3.1.5 B3.1.6 B3.1.7 B3.1.8 B3.2 B3.2.1 B3.2.2 B3.2.3 B3.3 B3.3.1.1 B3.3.1.2 B3.3.2.1 B3.3.2.2 B3.3.3.1 B3.3.3.2 B3.3.4.1 B3.3.4.2 B3.3.5.1 B3.3.5.2 B3. 3. 5.~~
B3.3.6.1 B3.3.6.2 B3.3.7.1 SAFETY LIMITS (SLs)............................................................................. TS/B2.0-1 Reactor Core SLs...................................................................... TS/B2.0-1 Reactor Coolant System (RCS) Pressure SL............................ TS/B2.0-6 LIMITING CONDITION FOR OPERATION (LCO) APPLICABILITY........ TS/B3.0-1 REACTIVITY CONTROL SYSTEMS..................................................... B3.1-1 Shutdown Margin (SOM)................................................................. B3.1-1 Reactivity Anomalies....................................................................... B3.1-8 Control Rod OPERABILITY....................................................... TS/B3.1-13 Control Rod Scram Times......................................................... TS/B3.1-22 Control Rod Scram Accumulators............................................. TS/B3.1-29 Rod Pattern Control................................................................... TS/B3.1-34 Standby Liquid Control (SLC) System....................................... TS/B3.1-39 Scram Discharge Volume (SDV) Vent and Drain Valves.......... TS/B3.1 -47 POWER DISTRIBUTION LIMITS.................................................... TS/B3.2-1 Average Planar Linear Heat Generation Rate (APLHGR)......... TS/B3.2-1 Minimum Critical Power Ratio (MCPR)...................................... TS/B3.2-5 Linear Heat Generation Rate (LHGR)....................................... TS/B3.2-10 INSTRUMENTATION...................................................................... TS/B3.3-1 Reactor Protection System (RPS) Instrumentation................... TS/B3.3-1 Source Range Monitor (SRM) Instrumentation.......................... TS/B3.3-35 Control Rod Block Instrumentation............................................ TS/B3.3-44 Feedwater - Main Turbine High Water Level Trip Instrumentation.................................................................... TS/B3.3-55 Post Accident Monitoring (PAM) Instrumentation...................... TS/B3.3-64 Remote Shutdown System........................................................ TS/B3.3-76 End of Cycle Recirculation Pump Trip (EOC-RPT)
Instrumentation.................................................................... TS/B3.3-81 Anticipated Transient Without Scram Recirculation Pump Trip (A TWS-RPT) Instrumentation.............................. TS/B3.3-92 Emergency Core Cooling System (ECCS)
Instrumentation.................................................................... TS/B3.3-101 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation....................................................................... B3.3-134A Reactor Core Isolation Cooling (RCIC) System Instrumentation.................................................................... TS/B3.3-135 Primary Containment Isolation Instrumentation............................... B3.3-14 7 Secondary Containment Isolation Instrumentation.................... TS/B3.3-180 Control Room Emergency Outside Air Supply (CREOAS)
System Instrumentation....................................................... TS/B3.3-192 (continued)
SUSQUEHANNA - UNIT 2 B TOC-1 Revision~
TABLE OF CONTENTS (TECHNICAL SPECIFICATIONS BASES)
B3.3 B3.3.8.1 B3.3.8.2 B3.4 B3.4.1 B3.4.2 B3.4.3 B3.4.4 B3.4.5 B3.4.6 B3.4.7 B3.4.8 B3.4.9 B3.4.10 B3.4.11 B3.5 B3.5.1 B3.5.2 B3.5.3 B3.6 B3.6.1.1 B3.6.1.2 B3.6.1.3 B3.6.1.4 B3.6.1.5 B3.6.1.6 B3.6.2.1 B3.6.2.2 B3.6.2.3 B3.6.2.4 B3.6.3.1 B3.6.3.2 B3.6.3.3 B3.6.4.1 B3.6.4.2 B3.6.4.3 INSTRUMENTATION (continued)
Loss of Power (LOP) Instrumentation....................................... TS/B3.3-206 Reactor Protection System (RPS) Electric Power Monitoring.................................................................................. B3.3-214 REACTOR COOLANT SYSTEM (RCS).......................................... TS/B3.4-1 Recirculation Loops Operating.................................................. TS/B3.4-1 Jet Pumps.................................................................................. TS/B3.4-1 0 Safety/Relief Valves (S/RVs)........................................................... B3.4-15 RCS Operational LEAKAGE...................................................... TS/B3.4-19 RCS Pressure Isolation Valve (PIV) Leakage........................... TS/B3.4-24 RCS Leakage Detection Instrumentation.................................. TS/B3.4-30 RCS Specific Activity................................................................. TS/B3.4-35 Residual Heat Removal (RHR) Shutdown Cooling System - Hot Shutdown...................................................... TS/B3.4-39 Residual Heat Removal (RHR) Shutdown Cooling System - Cold Shutdown.................................................... TS/B3.4-44 RCS Pressure and Temperature (PIT) Limits............................ TS/B3.4-49 Reactor Steam Dome Pressure.......................................... TS/B3.4-58 EMERGENCY CORE COOLING SYSTEMS (ECCS), REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM............................ TS/B3.5-1 ECCS - Operating..................................................................... TS/B3.5-1 Reactor Pressure Vessel (RPV) Water Inventory ControlECCS Shutdown TS/B3.5-19 RCIC System............................................................................. TS/B3.5-25 CONTAINMENT SYSTEMS............................................................ TS/B3.6-1 Primary Containment................................................................. TS/B3.6-1 Primary Containment Air Lock......................................................... B3.6-7 Primary Containment Isolation Valves (PCIVs)......................... TS/B3.6-15 Containment Pressure............................................................... TS/B3.6-40 Drywell Air Temperature............................................................ TS/B3.6-43 Suppression Chamber-to-Drywell Vacuum Breakers................ TS/B3.6-46 Suppression Pool Average Temperature.................................. TS/B3.6-52 Suppression Pool Water Level........................................................ B3.6-58 Residual Heat Removal (RHR) Suppression Pool Cooling....................................................................................... B3.6-61 Residual Heat Removal (RHR) Suppression Pool Spray................ B3.6-65 Not Used................................................................................... TS/B3.6-69 Drywell Air Flow System.................................................................. B3.6-75 Primary Containment Oxygen Concentration............................ TS/B3.6-80 Secondary Containment............................................................ TS/B3.6-83 Secondary Containment Isolation Valves (SC IVs).................... TS/B3.6-90 Standby Gas Treatment (SGT) System..................................... TS/B3.6-100 (continued)
SUSQUEHANNA - UNIT 2 B TOC - 2 Revision 2-J
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
ECCS Instrumentation B 3.3.5.1 ECCS instrumentation satisfies Criterion 3 of the NRC Policy Statement (Ref. 4). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
The OPERABILITY of the ECCS instrumentation is dependent upon the OPERABILITY of the individual instrumentation channel Functions specified in Table 3.3.5.1-1. Each Function must have a required number of OPERABLE channels, with their setpoints within the specified Allowable Values, where appropriate. The actual setpoint is calibrated consistent with applicable setpoint methodology assumptions. Each ECCS subsystem must also respond within its assumed response time.
Table 3.3.5.1-1, footnotes (e~) and (e.Q), are added to show that certain ECCS instrumentation Functions are also required to be OPERABLE to perform DG initiation and actuation of other Technical Specifications (TS) function.
Allowable Values are specified for each ECCS Function specified in the table. Nominal trip setpoints are specified in the setpoint calculations.
The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS.
Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. Trip setpoints are those predetermined values of output at which an action should take place. The setpoints are compared to the actual process parameter (e.g., reactor vessel water level), and when the measured output value of the process parameter reaches the setpoint, the associated device changes state. The analytic limits are derived from the limiting values of the process parameters obtained from the safety analysis. The Allowable Values are derived from the analytic limits, corrected for calibration, process, and some of the instrument errors.
The trip setpoints are then determined, accounting for the remaining instrument errors (e.g., drift). The trip setpoints derived in this manner (continued)
SUSQUEHANNA - UNIT 2 B3.3-108 Revision 4
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 1.a, 2.a.
Reactor Vessel Water Level-Low Low Low, Level 1 (continued)
Reactor Vessel Water Level-Low Low Low, Level 1 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-Low Low Low, Level 1 Allowable Value is chosen to allow time for the low pressure core flooding systems to activate and provide adequate cooling.
The initiation logic for LPCI pumps and injection valves is cross connected such that either division's start signal will start all four pumps and open both loop's injection valves. This cross division logic is required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the initiation circuitry is not required. Therefore, in MODES 4 and 5 for LPCI, only one division of initiation logic is required.
DGs C and D which are initiated from the LPCI LOCA initiation are cross connected such that both DGs receive an initiation signal from both Divisions of the LPCI LOCA initiation circuitry. This cross connected logic is only required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the DG initiation circuitry is not required. Therefore, in MODES 4 and 5 for DGs C and D only one division of EGGS initiation logic is required.
Four channels of Reactor Vessel Water Level-Low Low Low, Level 1 Function are only required to be OPERABLE when the ECCS or DG(s) are required to be OPERABLE to ensure that no single instrument failure can preclude ECCS and DG initiation. Refer to LCO 3.5.1 and LCO 3.5.2, "EGGS Shutdown," for Applicability Bases for the low pressure EGGS subsystems; LCO 3.8.1, "AC Sources Operating"; and LCO 3.8.2, "AC Sources Shutdown," for Applicability Bases for the DGs.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-110 Revision 4-
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 1.c, 1.d, 2.c, 2.d Reactor Steam Dome Pressure-Low (continued) subsystems' maximum design pressure. The Reactor Steam Dome Pressure-Low is one of the Functions assumed to be OPERABLE and capable of permitting initiation of the ECCS during the transients analyzed in Reference 2. In addition, the Reactor Steam Dome Pressure-Low Function is directly assumed in the analysis of the recirculation line break (Ref. 1 ). The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 1 O CFR 50.46.
The Reactor Steam Dome Pressure-Low signals are initiated from four pressure instruments that sense the reactor dome pressure.
The pressure instruments are set to actuate between the Upper and Lower Allowable Values on decreasing reactor dome pressure.
The Upper Allowable Value is low enough to ensure that the reactor dome pressure has fallen to a value below the Core Spray and RHR/LPCI maximum design pressures to preclude overpressurization.
The Lower Allowable Value is high enough to ensure that the ECCS injection prevents the fuel peak cladding temperature from exceeding the limits of 10 CFR 50.46.
DGs C and D which are initiated from the LPCI LOCA initiation are cross connected such that both DGs receive an initiation signal from both Divisions of the LPCI LOCA initiation circuitry. This cross connected logic is only required in MODES 1, 2, and 3. In MODES 4 and 5, redundancy in the DG initiation circuitry is not required. Therefore, in MODES 4 and 5 for DGs C and D only one division of ECCS initiation logic is required.
Four channels of Reactor Steam Dome Pressure-Low Function are required to be OPERABLE only when the ECCS is required to be OPERABLE to ensure that no single instrument failure can preclude ECCS initiation. Refer to LGO 3.5.1 and LGO 3.5.2 for Applicability Bases for the low pressure EGGS subsystems.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-112 Revision BASES ECCS Instrumentation B 3.3.5.1 APPLICABLE 1.e, 2.f.
Manual Initiation SAFETY ANALYSES LCO, and APPLICABILITY (continued)
The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to provide manual initiation capability and are redundant to the automatic protective instrumentation. There is one push button for each of the CS and LPCI subsystems (i.e., two for CS and two for LPCI).
The Manual Initiation Function is not assumed in any accident or transient analyses in the FSAR. However, the Function is retained for overall redundancy and diversity of the low pressure ECCS function as required by the NRC in the plant licensing basis.
There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
Each channel of the Manual Initiation Function (one channel per subsystem) is required to be OPERABLE only when the associated ECCS is required to be OPERABLE. Refer to LGO 3.5.1 and LGO 3.5.2 for 1\\pplicability Bases for the low pressure EGGS subsystems.
2.e. Reactor Steam Dome Pressure-Low (Recirculation Discharge Valve Permissive)
Low reactor steam dome pressure signals are used as permissives for recirculation discharge and bypass valves closure. This ensures that the LPCI subsystems inject into the proper RPV location assumed in the safety analysis. The Reactor Steam Dome Pressure-Low is one of the Functions assumed to be OPERABLE and capable of closing the valves during the transients analyzed in Reference 2. The core cooling function of the ECCS, along with the scram action of the RPS, ensures that the fuel peak cladding temperature remains below the limits of 10 CFR 50.46.
The Reactor Steam Dome Pressure-Low Function is directly assumed in the analysis of the recirculation line break (Ref. 1 ).
The Reactor Steam Dome Pressure-Low signals are initiated from four pressure instruments that sense the reactor dome pressure.
The Allowable Value is chosen to ensure that the valves close prior to commencement of LPCI injection flow into the core, as assumed in the safety analysis.
(continued)
SUSQUEHANNA - UNIT 2 B3.3-113 Revision~
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY ECCS Instrumentation B 3.3.5.1 3.c. Reactor Vessel Water Level-High, Level 8 (continued)
Two channels of Reactor Vessel Water Level-High, Level 8 Function are required to be OPERABLE only when HPCI is required to be OPERABLE. Refer to LCO 3.5.1 and LCO 3.5.2 for HPCI Applicability Bases.
3.d. Condensate Storage Tank Level-Low The Condensate Storage Tank-Low signal indicates that a conservatively calculated NPSH-available limit is being approached.
Normally the suction valves between HPCI and the CST are open and, upon receiving a HPCI initiation signal, water for HPCI injection would be taken from the CST. However, if the water level in the CST falls to the level switch process setpoint value, an automatic suction transfer is initiated. The suppression pool suction valve receives a signal to open and in parallel, the CST suction valve receives a signal to close to complete the transfer. The HPCI suction transfer must be initiated prior to CST level dropping below the technical specification allowable value to ensure that an adequate suction head for the pump and an uninterrupted supply of makeup water is available to the HPCI pump. The Function is implicitly assumed in the accident and transient analyses (which take credit for HPCI) since the analyses assume that the HPCI suction source is the suppression pool.
Condensate Storage Tank Level-Low signals are initiated from two level instruments. The logic is arranged such that either level switch can cause the suppression pool suction valves to open and the CST suction valve to close. The Condensate Storage Tank Level-Low Function Allowable Value is high enough to ensure adequate pump suction head while water is being taken from the CST.
Two channels of the Condensate Storage Tank Level-Low Function are required to be OPERABLE only when HPCI is required to be OPERABLE to ensure that no single instrument failure can preclude HPCI swap to suppression pool source. Refer to LCO 3.5.1 for HPCI Applicability Bases.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-116 Revision J
BASES ACTIONS B.1, B.2, and B.3 (continued)
ECCS Instrumentation B 3.3.5.1 For (b), (c) and (d) above, for each Division, since each inoperable channel would have Required Action B.1 applied separately (refer to ACTIONS Note), each inoperable channel would only require the affected portion of the associated system of low pressure ECCS, DGs, and associated features to be declared inoperable. However, since channels in both Divisions are inoperable and untripped, and the Completion Times started concurrently for the channels in both subsystems, this results in the affected portions in the associated low pressure ECCS and DGs being concurrently declared inoperable.
For Required Action B.2, redundant automatic initiation capability is lost if two Function 3.a or two Function 3.b channels are inoperable and untripped in the same trip system. In this situation (loss of redundant automatic initiation capability), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Action B.3 is not appropriate and the feature(s) associated with the inoperable, untripped channels must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. As noted (Note 1 to Required Action B.1), Required Action B.1 is only applicable in MODES 1, 2, and 3. In MODES 4 and 5, the specific initiation time of the low pressure EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of initiation capability for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (as allowed by Required Action B.3) is allowed during MODES 4 and 5. There is no similar Note provided for Required Action B.2 since HPGI instrumentation is not required in MODES 4 and 5; thus, a Note is not necessary. Notes are also provided (the Not~
to Required Action B.1 and the Note to Required Action B.2) to (continued)
SUSQUEHANNA - UNIT 2 B 3.3-124a Revision G
BASES ACTIONS (continued)
C.1 and C.2 ECCS Instrumentation B 3.3.5.1 INTERIM ADMINISTRATIVE DIRECTION Technical Specification Table 3.3.5.1-1, "HPCI System, Function 3.e, Conditions Referenced from Required Action A.1 " contains a typographical error (CR 620823). The "D" referenced should be "C." In accordance with Administrative Letter 98-10, direction is provided until ro osed TS chan e LDCN 3798 is a roved b the NRC.
Required Action C.1 is intended to ensure that appropriate actions are taken if multiple, inoperable channels within the same Function result in redundant automatic initiation capability being lost for the feature(s).
Required Action C.1 features would be those that are initiated by Functions 1.d, 2.d, and 2.e (i.e., low pressure ECCS). Redundant automatic initiation capability is lost if either (a) two or more Function 1.d channels are inoperable such that the trip system loses initiation capability, (b) two or more Function 2.d channels are inoperable in the same trip system such that the trip system loses initiation capability, or (c) two or more Function 2.e channels are inoperable affecting LPCI pumps in different subsystems. In this situation (loss of redundant automatic initiation capability), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Action C.2 is not appropriate and the feature(s) associated with the inoperable channels must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. Since each inoperable channel would have Required Action C.1 applied separately (refer to ACTIONS Note), each inoperable channel would only require the affected portion of the associated system to be declared inoperable. However, since channels for both low pressure ECCS subsystems are inoperable (e.g., both CS subsystems), and the Completion Times started concurrently for the channels in both subsystems, this results in the affected portions in both subsystems being concurrently declared inoperable. For Functions 1.d, 2.d, and 2.e, the affected portions are the associated low pressure ECCS pumps. As noted (Note 1 ), Required Action G.1 is only applicable in MODES 1, 2, and 3. In MODES 4 and 5, the specific initiation time of the EGGS is not assumed and the probability of a LOGA is lower. Thus, a total loss of automatic initiation capability for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (as allowed by Required Action G.2) is allowed during MODES 4 and 5.
The Not~
states that Required Action C.1 is only applicable for Functions 1.d, 2.d, and 2.e. Required Action C.1 is not applicable to Functions 1.e, 2.f, and 3.e (which also require entry into this Condition if a channel in these Functions is inoperable), since they are the Manual Initiation Functions and are not assumed in any accident or transient (continued)
SUSQUEHANNA - UNIT 2 B 3.3-126 Revision 2
Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 B 3.3 INSTRUMENTATION B 3.3.5.2 Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation BASES BACKGROUND The RPV contains penetrations below the top of the active fuel (T AF) that have the potential to drain the reactor coolant inventory to below the TAF.
If the water level should drop below the TAF. the ability to remove decay heat is reduced. which could lead to elevated cladding temperatures and clad perforation. Safety Limit 2.1.1.3 requires the RPV water level to be above the top of the active irradiated fuel at all times to prevent such elevated cladding temperatures.
Technical Specifications are required by 10 CFR 50.36 to include limiting safety system settings (LSSS) for variables that have significant safety functions. LSSS are defined by the regulation as "Where a LSSS is specified for a variable on which a safety limit has been placed. the setting must be chosen so that automatic protective actions will correct the abnormal situation before a Safety Limit (SL) is exceeded." The Analytical Limit is the limit of the process variable at which a safety action is initiated to ensure that a SL is not exceeded. Any automatic protection action that occurs on reaching the Analytical Limit therefore ensures that the SL is not exceeded. However. in practice. the actual settings for automatic protection channels must be chosen to be more conservative than the Analytical Limit to account for instrument loop uncertainties related to the setting at which the automatic protective action would actually occur. The actual settings for the automatic isolation channels are the same as those established for the same functions in MODES 1. 2.
and 3 in LCO 3.3.5.1. "Emergency Core Cooling System (ECCS)
Instrumentation," or LCO 3.3.6.1. "Primary Containment Isolation instrumentation".
With the unit in MODE 4 or 5. RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses.
RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur. Under the definition of DRAIN TIME. some penetration flow paths may be excluded from the DRAIN TIME calculation if they will be isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation.
SUSQUEHANNA - UNIT 2 B 3.3-134A
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.
5.2 BACKGROUND
(continued)
APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY The purpose of the RPV Water Inventory Control Instrumentation is to support the requirements of LCO 3.5.2. "Reactor Pressure Vessel (RPV)
Water Inventory Control," and the definition of DRAIN TIME. There are functions that are required for manual initiation or operation of the ECCS injection/spray subsystem required to be OPERABLE by LCO 3.5.2 and other functions that support automatic isolation of Residual Heat Removal subsystem and Reactor Water Cleanup system penetration flow path(s) on low RPV water level.
The RPV Water Inventory Control Instrumentation supports operation of core spray (CS) and low pressure coolant injection (LPCI). The equipment involved with each of these systems is described in the Bases for LCO 3.5.2.
With the unit in MODE 4 or 5, RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses. RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material should a draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure.
reduced piping stresses. and ductile piping systems. Instead. an event is postulated in which a single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate. or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g.,
seismic event. loss of normal power, single human error). It is assumed.
based on engineering judgment, that while in MODES 4 and 5, one low pressure ECCS injection/spray subsystem can be manually initiated to maintain adequate reactor vessel water level.
As discussed in References 1. 2. 3, 4. and 5. operating experience has shown RPV water inventory to be significant to public health and safety.
Therefore. RPV Water Inventory Control satisfies Criterion 4 of 10 CFR 50.36(c)(2)(ii).
Permissive and interlock setpoints are generally considered as nominal values without regard to measurement accuracy.
The specific Applicable Safety Analyses. LCO, and Applicability discussions are listed below on a Function by Function basis.
SUSQUEHANNA - UNIT 2 B 3.3-134B
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
Core Spray and Low Pressure Coolant Injection Systems 1.a, 2.a. Reactor Steam Dome Pressure - Low (Injection Permissive)
Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. This function ensures that. prior to opening the injection valves of the low pressure ECCS subsystems, the reactor pressure has fallen to a value below these subsystems' maximum design pressure. While it is assured during MODES 4 and 5 that the reactor steam dome pressure will be below the ECCS maximum design pressure. the Reactor Steam Dome Pressure - Low signals are assumed to be OPERABLE and capable of permitting initiation of the ECCS.
The Reactor Steam Dome Pressure - Low signals are initiated from four pressure transmitters that sense the reactor dome pressure. The transmitters are connected to four trip units. The outputs of the trip units are connected to relays whose contacts are arranged in a one-out-of-two taken twice logic.
The Allowable Value is low enough to prevent overpressuring the equipment in the low pressure ECCS.
The four channels of Reactor Steam Dome Pressure - Low Function are required to be OPERABLE in MODES 4 and 5 when ECCS manual initiation is required to be OPERABLE by LCO 3.5.2.
SUSQUEHANNA - UNIT 2 B 3.3-134C
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued) 1.b, 2.b. Manual Initiation The Manual Initiation push button channels introduce signals into the appropriate ECCS logic to provide manual initiation capability. There is one push button for each of the CS and LPCI subsystems (i.e., two for CS and two for LPCI).
There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
A channel of the Manual Initiation Function (one channel per subsystem) is required to be OPERABLE in MODES 4 and 5 when the associated ECCS subsystems are required to be OPERABLE per LCO 3.5.2.
RHR System Isolation 3.a - Reactor Vessel Water Level - Low, Level 3 The definition of DRAIN TIME allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation. The Reactor Vessel Water Level - Low. Level 3 Function associated with RHR System isolation may be credited for automatic isolation of penetration flow paths associated with the RHR System.
Reactor Vessel Water Level - Low, Level 3 signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level - Low, Level 3 Function are available. only two channels (all in the same trip system) are required to be OPERABLE.
The Reactor Vessel Water Level - Low, Level 3 Allowable Value was chosen to be the same as the Primary Containment Isolation Instrumentation Reactor Vessel Water Level - Low. Level 3 Allowable Value (LCO 3.3.6.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low, Level 3 Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
SUSQUEHANNA - UNIT 2 B 3.3-134D
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 APPLICABLE SAFETY ANALYSES, LCO. and APPLICABILITY (continued)
Reactor Water Cleanup (RWCU) System Isolation 4.a - Reactor Vessel Water level - Low Low, Level 2 The definition of DRAIN TIME allows crediting the closing of penetration flow paths that are capable of being isolated by valves that will close automatically without offsite power prior to the RPV water level being equal to the TAF when actuated by RPV water level isolation instrumentation. The Reactor Vessel Water Level - Low Low, Level 2 Function associated with RWCU System isolation may be credited for automatic isolation of penetration flow paths associated with the RWCU System.
Reactor Vessel Water Level - Low Low, Level 2 signals are initiated from four level transmitters that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. While four channels (two channels per trip system) of the Reactor Vessel Water Level -
Low Low, Level 2 Function are available. only two channels (all in the same trip system) are required to be OPERABLE.
The Reactor Vessel Water Level - Low Low, Level 2 Allowable Value was chosen to be the same as the ECCS Reactor Vessel Water Level - Low Low. Level 2 Allowable Value (LCO 3.3.5.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level - Low Low, Level 2 Function is only required to be OPERABLE when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME.
SUSQUEHANNA - UNIT 2 B 3.3-134E
BASES ACTIONS Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 A Note has been provided to modify the ACTIONS related to RPV Water Inventory Control instrumentation channels. Section 1.3, Completion Times. specifies that once a Condition has been entered. subsequent divisions. subsystems, components. or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions continue to apply for each additional failure. with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable RPV Water Inventory Control instrumentation channels provide appropriate compensatory measures for separate inoperable Condition entry for each inoperable RPV Water Inventory Control instrumentation channel.
Required Action A.1 directs entry into the appropriate Condition referenced in Table 3.3.5.2-1. The applicable Condition referenced in the Table is Function dependent. Each time a channel is discovered inoperable. Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
B.1 and B.2 RHR System Isolation. Reactor Vessel Water Level - Low Level 3, and Reactor Water Cleanup System. Reactor Vessel Water Level - Low Low.
Level 2 functions are applicable when automatic isolation of the associated penetration flow path is credited in calculating DRAIN TIME. If the instrumentation is inoperable. Required Action B.1 directs an immediate declaration that the associated penetration flow path(s) are incapable of automatic isolation. Required Action B.2 directs calculation of DRAIN TIME. The calculation cannot credit automatic isolation of the affected penetration flow paths.
SUSQUEHANNA - UNIT 2 B 3.3-134F
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 ACTIONS (continued)
Low reactor steam dome pressure signals are used as permissives for the low pressure ECCS injection/spray subsystem manual injection functions. If the permissive is inoperable. manual initiation of ECCS is prohibited. Therefore, the permissive must be placed in the trip condition within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />. With the permissive in the trip condition, manual initiation may be performed. Prior to placing the permissive in the tripped condition. the operator can take manual control of the pump and the injection valve to inject water into the RPV.
The Completion Time of 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> is intended to allow the operator time to evaluate any discovered inoperabilities and to place the channel in trip.
If a manual initiation function is inoperable, the ECCS subsystem pumps can be started manually and the valves can be opened manually, but this is not the preferred condition.
The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time was chosen to allow time for the operator to evaluate and repair any discovered inoperabilities. The Completion Time is appropriate given the ability to manually start the ECCS pumps and open the injection valves.
With the Required Action and associated Completion Time of Condition C or D not met. the associated low pressure ECCS injection/spray subsystem may be incapable of performing the intended function. and must be declared inoperable immediately.
SUSQUEHANNA - UNIT 2 B 3.3-134G
BASES SURVEILLANCE REQUIREMENTS Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 As noted in the beginning of the SRs. the SRs for each RPV Water Inventory Control instrument Function are found in the SRs column of Table 3.3.5.2-1.
SR 3.3.5.2.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a similar parameter on other channels. It is based on the assumption that instrument channels monitoring the same parameter should read approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK guarantees that undetected outright channel failure is limited; thus. it is key to verifying the instrumentation continues to operate properly between each CHANNEL FUNCTIONAL TEST.
Agreement criteria are determined by the plant staff. based on a combination of the channel instrument uncertainties. including indication and readability. If a channel is outside the criteria. it may be an indication that the instrument has drifted outside its limit.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The CHANNEL CHECK supplements less formal, but more frequent.
checks of channels during normal operational use of the displays associated with the channels required by the LCO.
. A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function.
This SR is modified by a Note that provides a general exception to the definition of CHANNEL FUNCTIONAL TEST. This exception is necessary because the design of instrumentation does not facilitate functional testing of all required contacts of the relay which input into the combinational logic.
Performance of such a test could result in a plant transient or place the plant in an undue risk situation. Therefore. for this SR, the CHANNEL FUNCTIONAL TEST verifies acceptable response by verifying the change of state of the relay which inputs into the combinational logic. The required contacts not tested during the CHANNEL FUNCTIONAL TEST are tested under the LOGIC SYSTEM FUNCTIONAL TEST. SR 3.3.5.2.3. This is acceptable because operating experience shows that the contacts not tested during the CHANNEL FUNCTIONAL TEST normally pass the SUSQUEHANNA - UNIT 2 B 3.3-134H
BASES Reactor Pressure Vessel (RPV) Water Inventory Control Instrumentation B 3.3.5.2 SURVEILLANCE REQUIREMENTS (continued)
SR 3.3.5.2.2 (Continued)
REFERENCES LOGIC SYSTEM FUNCTIONAL TEST, and the testing methodology minimizes the risk of unplanned transients.
Any setpoint adjustment shall be consistent with the assumptions of the current plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.3.5.2.3 The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic for a specific channel. The system functional testing performed in LCO 3.5.2 overlaps this Surveillance to complete testing of the assumed safety function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
- 1.
Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup,"
November 1984.
- 2.
Information Notice 86-74, "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves." August 1986.
- 3.
Generic Letter 92-04. "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10 CFR 50.54(F), "August 1992.
- 4.
NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs," May 1993.
- 5.
Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1," July 1994.
SUSQUEHANNA - UNIT 2 B 3.3-1341
RCIC System Instrumentation B 3. 3.5.~~
B 3.3 INSTRUMENTATION B 3. 3. 5.~~ Reactor Core Isolation Cooling (RCIC) System Instrumentation BASES BACKGROUND The purpose of the RCIC System instrumentation is to initiate actions to ensure adequate core cooling when the reactor vessel is isolated from its primary heat sink (the main condenser) and normal coolant makeup flow from the Reactor Feedwater System is unavailable, such that initiation of the low pressure Emergency Core Cooling Systems (ECCS) pumps does not occur. A more complete discussion of RCIC System operation is provided in the Bases of LCO 3.5.3, "RCIC System."
The RCIC System may be initiated by either automatic or manual means.
Automatic initiation occurs for conditions of reactor vessel Low Low water level. The variable is monitored by four instruments. The outputs of the trip units are connected to relays whose contacts are arranged in a one-out-of-two taken twice logic arrangement. Once initiated, the RCIC logic seals in and can be reset by the operator only when the reactor vessel water level signals have cleared.
The RCIC test line isolation valve is closed on a RCIC initiation signal to allow full system flow and maintain primary containment isolated in the event RCIC is not operating.
The RCIC System also monitors the water levels in the condensate storage tank (CST) which is the normal suction source of reactor grade water for RCIC. Upon receipt of a RCIC initiation signal, the CST suction valve is automatically signaled to open (it is normally in the open position) unless the pump suction from the suppression pool valve is open. If the water level in the CST falls below a preselected level, first the suppression pool suction valve automatically opens, and then the CST suction valve automatically closes. Two level switches are used to detect low water level in the CST. Either switch can cause the suppression pool suction valve to open and the CST suction valve to close.
The RCIC System provides makeup water to the reactor until the reactor vessel water level reaches the high water level (continued)
SUSQUEHANNA - UNIT 2 TS I B 3.3-135 Revision G
BASES BACKGROUND (continued)
APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY RCIC System Instrumentation B 3.3.5.~~
(Level 8) trip (two-out-of-two logic), at which time the RCIC steam supply and cooling water supply valves close (the injection valve also closes due to the closure of the steam supply valves). The RCIC System restarts if vessel level again drops to the low level initiation point (Level 2).
The function of the RCIC System to provide makeup coolant to the reactor is used to respond to transient events. The RCIC System is not an Engineered Safety Feature System and no credit is taken in the safety analyses for RCIC System operation. Based on its contribution to the reduction of overall plant risk, however, the system, and therefore its instrumentation, are included in the Technical Specifications as required by the NRC Policy Statement (Ref. 2). Certain instrumentation Functions are retained for other reasons and are described below in the individual Functions discussion.
The OPERABILITY of the RCIC System instrumentation is dependent upon the OPERABILITY of the individual instrumentation channel Functions specified in Table 3. 3. 5.~~- 1. Each Function must have a required number of OPERABLE channels with their setpoints within the specified Allowable Values, where appropriate. A channel is inoperable if its actual trip setpoint is not within its required Allowable Value. The actual setpoint is calibrated consistent with applicable setpoint methodology assumptions.
Allowable Values are specified for each RCIC System instrumentation Function specified in the Table. Nominal trip setpoints are specified in the setpoint calculations. The nominal setpoints are selected to ensure that the setpoints do not exceed the Allowable Value between CHANNEL CALIBRATIONS. Operation with a trip setpoint less conservative than the nominal trip setpoint, but within its Allowable Value, is acceptable.
Each Allowable Value specified accounts for instrument uncertainties appropriate to the Function. These uncertainties are described in the setpoint methodology.
An exception to the methodology described to derive the Allowable Value is the methodology used to determine the Allowable Value for the Condensate Storage Tank Low Level. This Allowable Value is based on a system calculation and (continued)
SUSQUEHANNA - UNIT 2 B3.3-136 Revision Q
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
RCIC System Instrumentation B 3. 3.5.~~
and engineering judgement which establishes a conseNative limit at which the Function should occur.
The individual Functions are required to be OPERABLE in MODE 1, and in MODES 2 and 3 with reactor steam dome pressure > 150 psig since this is when RCIC is required to be OPERABLE. (Refer to LCO 3.5.3 for Applicability Bases for the RCIC System.)
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
- 1.
Reactor Vessel Water Level-Low Low, Level 2 Low reactor pressure vessel (RPV) water level indicates that normal feedwater flow is insufficient to maintain reactor vessel water level and that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, the RCIC System is initiated at Level 2 to assist in maintaining water level above the top of the active fuel.
Reactor Vessel Water Level-Low Low, Level 2 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-Low Low, Level 2 Allowable Value is set high enough such that for complete loss of feedwater flow, the RCIC System flow with high pressure coolant injection assumed to fail will be sufficient to avoid initiation of low pressure ECCS at Level 1.
Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
(continued)
SUSQUEHANNA - UNIT 2 B3.3-137 Revision G
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
RCIC System Instrumentation B 3.3.5.~~
- 2.
Reactor Vessel Water Level-High, Level 8 High RPV water level indicates that sufficient cooling water inventory exists in the reactor vessel such that there is no danger to the fuel.
Therefore, the Level 8 signal is used to close the RCIC steam supply and cooling water supply valves to prevent overflow into the main steam lines (MSLs). (The injection valve also closes due to the closure of the steam supply valve.)
Reactor Vessel Water Level-High, Level 8 signals for RCIC are initiated from two level instruments, which sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel.
The Reactor Vessel Water Level-High, Level 8 Allowable Value is high enough to preclude isolating the injection valve of the RCIC during normal operation, yet low enough to trip the RCIC System prior to water overflowing into the MSLs.
Two channels of Reactor Vessel Water Level-High, Level 8 Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC initiation. Refer to LCO 3.5.3 for RCIC Applicability Bases.
- 3.
Condensate Storage Tank Level-Low The Condensate Storage Tank-Low signal indicates that a conservatively calculated NPSH-available limit is being approached. Normally, the suction valve between the RCIC pump and the CST is open and, upon receiving a RCIC initiation signal, water for RCIC injection would be taken from the CST. However, if the water level in the CST falls below a preselected level, first the suppression pool suction valve automatically opens, and then the CST suction valve automatically closes. This ensures that an adequate suction head for the pump and an uninterrupted supply of makeup water is available to the RCIC pump should it be desired to realign the suction to the remaining reserve volume in the CST. This logic also has a manual override function initiated by manual closure of the suppression pool suction valve. To prevent losing suction to the pump, the suction valves are interlocked so that the suppression pool suction valves must be open before the CST suction valve automatically closes.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-138 Revision 4-
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY ACTIONS RCIC System Instrumentation B 3. 3. 5.~~
- 3.
Condensate Storage Tank Level-Low (continued)
Two level switches are used to detect low water level in the CST. The Condensate Storage Tank Level-Low Function Allowable Value is set high enough to ensure adequate pump suction head while water is being taken from the CST.
Two channels of Condensate Storage Tank Level-Low Function are available and are required to be OPERABLE when RCIC is required to be OPERABLE to ensure that no single instrument failure can preclude RCIC swap to suppression pool source. Refer to LCO 3.5.3 for RCIC Applicability Bases.
- 4.
Manual Initiation The Manual Initiation push button switch introduces a signal into the RCIC System initiation logic that is redundant to the automatic protective instrumentation and provides manual initiation capability. There is one push button for the RCIC System resulting in a single channel trip Function.
The Manual Initiation Function is not assumed in any accident or transient analyses in the FSAR. However, the Function is retained for overall redundancy and diversity of the RCIC function as required by the NRC in the plant licensing basis.
There is no Allowable Value for this Function since the channel is mechanically actuated based solely on the position of the push button.
One channel of Manual Initiation is required to be OPERABLE when RCIC is required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to RCIC System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition discovered to be inoperable or not within limits will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for (continued)
SUSQUEHANNA - UNIT 2 B3.3-139 Revision Q
BASES ACTIONS (continued)
RCIC System Instrumentation B 3. 3. 5.~~
inoperable RCIC System instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable RCIC System instrumentation channel.
Required Action A.1 directs entry into the appropriate Condition referenced in Table 3.3.5.~~-1. The applicable Condition referenced in the Table is Function dependent. Each time a channel is discovered to be inoperable, Condition A is entered for that channel and provides for transfer to the appropriate subsequent Condition.
8.1 and 8.2 Required Action 8.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in a complete loss of automatic initiation capability for the RCIC System. In this case, automatic initiation capability is lost if two Function 1 channels in the same trip system are inoperable and untripped. In this situation (loss of automatic initiation capability), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Action 8.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> after discovery of loss of RCIC initiation capability.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action 8.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically initiated due to two inoperable, untripped Reactor Vessel Water Level-Low Low, Level 2 channels in the same trip system. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time from discovery of loss of initiation capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-140 Revision 0
BASES ACTIONS B.1 and B.2 (continued)
RCIC System Instrumentation B 3.3.5.~~
Because of the redundancy of sensors available to provide initiation signals and the fact that the RCIC System is not assumed in any accident or transient analysis, an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed in the tripped condition per Required Action B.2. Placing the inoperable channel in trip would conservatively compensate for the inoperability, restore capability to accommodate a single failure, and allow operation to continue.
Alternately, if it is not desired to place the channel in trip (e.g., as in the case where placing the inoperable channel in trip would result in an initiation), Condition E must be entered and its Required Action taken.
A risk based analysis was performed and determined that an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (Ref. 1) is acceptable to permit restoration of any inoperable channel to OPERABLE status (Required Action C.1 ). A Required Action (similar to Required Action B.1) limiting the allowable out of service time, if a loss of automatic RCIC initiation capability exists, is not required. This Condition applies to the Reactor Vessel Water Level-High, Level 8 Function whose logic is arranged such that any inoperable channel will result in a loss of automatic RCIC trip protection capability.
As stated above, this loss of automatic RCIC trip protection capability was analyzed and determined to be acceptable. This Condition also applies to the Manual Initiation Function. Since this Function is not assumed in any accident or transient analysis, a total loss of manual initiation capability (Required Action C.1) for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is allowed. The Required Action does not allow placing a channel in trip since this action would not necessarily result in a safe state for the channel in all events.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-141 Revision G
BASES ACTIONS (continued) 0.1. 0.2.1. and 0.2.2 RCIC System Instrumentation B 3. 3. 5.~~
Required Action 0.1 is intended to ensure that appropriate actions are taken if multiple, inoperable, untripped channels within the same Function result in automatic component initiation capability being lost for the feature(s). For Required Action 0.1, the RCIC System is the only associated feature. In this case, automatic initiation capability is lost if two Function 3 channels are inoperable and untripped. In this situation (loss of automatic suction swap), the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowance of Required Actions D.2.1 and D.2.2 is not appropriate, and the RCIC System must be declared inoperable within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> from discovery of loss of RCIC initiation capability. A note identifies that required Action 0.1 is only applicable if the RCIC pump suction is not aligned to the suppression pool since, if aligned, the Function is already performed. This allows the RCIC pump suction to be realigned to the suppression pool within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, if desired.
The Completion Time is intended to allow the operator time to evaluate and repair any discovered inoperabilities. This Completion Time also allows for an exception to the normal "time zero" for beginning the allowed outage time "clock." For Required Action D.1, the Completion Time only begins upon discovery that the RCIC System cannot be automatically aligned to the suppression pool due to two inoperable, untripped channels in the same Function. The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time from discovery of loss of initiation capability is acceptable because it minimizes risk while allowing time for restoration or tripping of channels.
Because of the redundancy of sensors available to provide initiation signals and the fact that the RCIC System is not assumed in any accident or transient analysis, an allowable out of service time of 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> has been shown to be acceptable (Ref. 1) to permit restoration of any inoperable channel to OPERABLE status. If the inoperable channel cannot be restored to OPERABLE status within the allowable out of service time, the channel must be placed in the tripped condition per Required Action D.2.1, which performs the intended function of the channel (shifting the suction source to the suppression pool).
Alternatively, Required Action D.2.2 allows the manual alignment of the RCIC suction (continued)
SUSQUEHANNA - UNIT 2 B 3.3-142 Revision Q
BASES ACTIONS SURVEILLANCE REQUIREMENTS D.1, D.2, and D.2.2 (continued)
RCIC System Instrumentation B 3.3. 5.2~
to the suppression pool, which also performs the intended function. If it is not desired to perform Required Actions D.2.1 and D.2.2, Condition E must be entered and its Required Action taken.
With any Required Action and associated Completion Time not met, the RCIC System may be incapable of performing the intended function, and the RCIC System must be declared inoperable immediately.
As noted in the beginning of the SRs, the SRs for each RCIC System instrumentation Function are found in the SRs column of Table 3. 3. 5.2~- 1 The Surveillances are modified by a Note to indicate that when a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed as follows: (a) for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for Function 2 and 4; and (b) for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> for Functions other than Function 2 and 4, provided the associated Function maintains trip capability. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken. This Note is based on the reliability analysis (Ref. 1) assumption of the average time required to perform channel surveillance. That analysis demonstrated that the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> testing allowance does not significantly reduce the probability that the RCIC will initiate when necessary.
SR 3.3.5.23.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one channel to a parameter on other similar channels. It is based on the assumption that instrument channels monitoring the same parameter should read (continued)
SUSQUEHANNA - UNIT 2 B 3.3-143 Revision 4
BASES SURVEILLANCE REQUIREMENTS SR 3.3.5.~3. 1 (continued)
RCIC System Instrumentation B 3. 3. 5.~~
approximately the same value. Significant deviations between the instrument channels could be an indication of excessive instrument drift in one of the channels or something even more serious. A CHANNEL CHECK will detect gross channel failure; thus, it is key to verifying the instrumentation continues to operate properly between each CHANNEL CALIBRATION.
Agreement criteria which are determined by the plant staff based on an investigation of a combination of the channel instrument uncertainties may be used to support this parameter comparison and include indication and readability. If a channel is outside the criteria, it may be an indication that the instrument has drifted outside its limit, and does not necessarily indicate the channel is Inoperable.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3. 3. 5.~3. 2 A CHANNEL FUNCTIONAL TEST is performed on each required channel to ensure that the entire channel will perform the intended function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
This SR is modified by a Note that provides a general exception to the definition of CHANNEL FUNCTIONAL TEST. This exception is necessary because the design of instrumentation does not facilitate functional testing of all required contacts of the relay which input into the combinational logic. (Reference 3) Performance of such a test could result in a plant transient or place the plant in an undo risk situation.
Therefore, for this SR, the CHANNEL FUNCTIONAL TEST verifies acceptable response by verifying (continued)
SUSQUEHANNA - UNIT 2 B 3.3-144 Revision-+
BASES SURVEILLANCE REQUIREMENTS SR 3.3.5.23.2 (continued)
RCIC System Instrumentation B 3. 3. 5.2~
the change of state of the relay which inputs into the combinational logic.
The required contacts not tested during the CHANNEL FUNCTIONAL TEST are tested under the LOGIC SYSTEM FUNCTIONAL TEST, SR 3. 3.5.2~. 5. This is acceptable because operating experience shows that the contacts not tested during the CHANNEL FUNCTIONAL TEST normally pass the LOGIC SYSTEM FUNCTIONAL TEST, and the testing methodology minimizes the risk of unplanned transients.
SR 3.3.5.23.3 and SR 3.3.5.23.4 A CHANNEL CALIBRATION verifies that the channel responds to the measured parameter within the necessary range and accuracy.
CHANNEL CALIBRATION leaves the channel adjusted to account for instrument drifts between successive calibrations consistent with the plant specific setpoint methodology.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.3.5.23.5 The LOGIC SYSTEM FUNCTIONAL TEST demonstrates the OPERABILITY of the required initiation logic for a specific channel. The system functional testing performed in LCO 3.5.3 overlaps this Surveillance to provide complete testing of the safety function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-145 Revision 4-
BASES REFERENCES RCIC System Instrumentation B 3. 3. 5.~~
- 1.
NEDE-770-06-2, "Addendum to Bases for Changes to Surveillance Test Intervals and Allowed Out-of-Service Times for Selected Instrumentation Technical Specifications," February 1991.
- 2.
Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 32193).
- 3.
NRC Inspection and Enforcement Manual, Part 9900: Technical Guidance, Standard Technical Specification Section 1.0 Definitions, Issue date 12/08/86.
SUSQUEHANNA - UNIT 2 3.3-146 Revision-+
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY (continued)
Primary Containment Isolation Instrumentation B 3.3.6.1 6.b. Reactor Vessel Water Level-Low. Level 3 Low RPV water level indicates that the capability to cool the fuel may be threatened. Should RPV water level decrease too far, fuel damage could result. Therefore, isolation of some reactor vessel interfaces occurs to begin isolating the potential sources of a break. The Reactor Vessel Water Level-Low, Level 3 Function associated with RHR Shutdown Cooling System isolation is not directly assumed in safety analyses because a break of the RHR Shutdown Cooling System is bounded by breaks of the recirculation and MSL.
The RHR Shutdown Cooling System isolation on Level 3 supports actions to ensure that the RPV water level does not drop below the top of the active fuel during a vessel draindown event caused by a leak (e.g., pipe break or inadvertent valve opening) in the RHR Shutdown Cooling System.
Reactor Vessel Water Level-Low, Level 3 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels (two channels per trip system) of the Reactor Vessel Water Level-Low, Level 3 Function are available and are required to be OPERABLE to ensure that no single instrument failure can preclude the isolation function. i\\s noted (footnote (c) to Table 3.3.6.1 1 ), only 1?.vo channels of the Reactor Vessel V'Jater Level Lo1,\\1, Level 3 Function are required to be OPERABLE in MODES 4 and 5 (and must input into the same trip system), provided the RHR Shutdown Cooling System integrity is maintained. System integrity is maintained provided the piping is intact and no maintenance is being performed that has the potential for draining the reactor 'Jessel through the system.
The Reactor Vessel Water Level-Low, Level 3 Allowable Value was chosen to be the same as the RPS Reactor Vessel Water Level-Low, Level 3 Allowable Value (LCO 3.3.1.1 ), since the capability to cool the fuel may be threatened.
The Reactor Vessel Water Level-Low, Level 3 Function is only required to be OPERABLE in MODES 3, 4, and 5 to prevent this potential flow path from lowering the reactor vessel level to the top of the fuel.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-168 Revision-+
BASES APPLICABLE SAFETY ANALYSES, LCO, and APPLICABILITY Primary Containment Isolation Instrumentation B 3.3.6.1 6.b. Reactor Vessel Water Level-Low. Level 3 (continued)
In MODES 1 and 2, another isolation (i.e., Reactor Steam Dome Pressure-High) and administrative controls ensure that this flow path remains isolated to prevent unexpected loss of inventory via this flow path.
6.c Manual Initiation The Manual Initiation push button channels introduce signals to RHR Shutdown Cooling System isolation logic that is redundant to the automatic protective instrumentation and provide manual isolation capability. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for overall redundancy and diversity of the isolation function as required by the NRC in the plant licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of the Manual Initiation Function are available and are required to be OPERABLE in MODES 3, 4, and 5, since these are the MODES in which the RHR Shutdown Cooling System Isolation automatic Function are required to be OPERABLE.
- A.s noted (footnote (c) to Table 3.3.6.1 1 ), only one channel of the Manual Initiation Function is required to be OPERABLE in MODES 4 and 5 provided the RHR Shutdown Cooling System integrity is maintained.
System integrity is maintained provided the piping is intact and no maintenance is being performed that has the potential for draining the reactor vessel through the system.
Traversing lncore Probe System Isolation 7.a Reactor Vessel Water Level - Low, Level 3 Low RPV water level indicates that the capability to cool the fuel may be threatened. The valves whose penetrations communicate with the primary containment are isolated to limit the release of fission products.
The isolation of the primary containment on Level 3 supports actions to (continued)
SUSQUEHANNA - UNIT 2 B 3.3-169 Revision J
BASES ACTIONS SURVEILLANCE REQUIREMENTS 1.1 and 1.2 (continued Primary Containment Isolation Instrumentation B 3.3.6.1 The 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Completion Time is acceptable because it minimizes risk while allowing sufficient time for personnel to isolate the RWCU System.
J.1 and J.2 If the channel is not restored to OPERABLE status or placed in trip within the allowed Completion Time, the associated penetration flow path should be closed. However, if the shutdown cooling function is needed to provide core cooling, these Required Actions allow the penetration flow path to remain unisolated provided action is immediately initiated to restore the channel to OPERABLE status~ or to isolate the RHR Shutdown Cooling System (i.e., provide alternate decay heat removal capabilities so the penetration flow path can be isolated). Actions must continue until the channel is restored to OPERABLE status or the RHR Shutdown Cooling System is isolated.
As noted at the beginning of the SRs, the SRs for each Primary Containment Isolation instrumentation Function are found in the SRs column of Table 3.3.6.1-1.
The Surveillances are modified by a Note to indicate that when a channel is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and Required Actions may be delayed for up to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided the associated Function maintains trip capability. Upon completion of the Surveillance, or expiration of the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> allowance, the channel must be returned to OPERABLE status or the applicable Condition entered and Required Actions taken. This Note is based on the reliability analysis (Refs. 5 and 6) assumption of the average time required to perform channel surveillance. That analysis demonstrated that the 6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> testing allowance does not significantly reduce the probability that the PC IVs will isolate the penetration flow path(s) when necessary.
SR 3.3.6.1.1 Performance of the CHANNEL CHECK ensures that a gross failure of instrumentation has not occurred. A CHANNEL CHECK is normally a comparison of the parameter indicated on one (continued)
SUSQUEHANNA - UNIT 2 B 3.3-175 Revision 2
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY Secondary Containment Isolation Instrumentation B 3.3.6.2
- 1. Reactor Vessel Water Level-Low Low. Level 2 (continued) level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available and are required to be OPERABLE to ensure that no single instrument failure can preclude the isolation function.
The Reactor Vessel Water Level-Low Low, Level 2 Allowable Value was chosen to be the same as the High Pressure Coolant Injection/Reactor Core Isolation Cooling (HPCl/RCIC) Reactor Vessel Water Level-Low Low, Level 2 Allowable Value (LCO 3.3.5.1 and LCO 3.3.5.2J), since this could indicate that the capability to cool the fuel is being threatened.
The Reactor Vessel Water Level-Low Low, Level 2 Function is required to be OPERABLE in MODES 1, 2, and 3 where considerable energy exists in the Reactor Coolant System (RCS); thus, there is a probability of pipe breaks resulting in significant releases of radioactive steam and gas. In MODES 4 and 5, the probability and consequences of these events are low due to the RCS pressure and temperature limitations of these MODES; thus, this Function is not required. In addition, the Function is also required to be OPERABLE during operations with a potential f.or draining the reactor vessel (OPDRVs) because the capability of isolating potential sources of leakage must be provided to ensure that offsite and control room dose limits are not exceeded if core damage occurs.
Reactor Vessel Water Level--Low Low, Level 2 will isolate the affected Unit's zone (i.e., Zone I for Unit 1 and Zone II for Unit 2) and Zone Ill.
- 2. Drywell Pressure-High High drywell pressure can indicate a break in the reactor coolant pressure boundary (RCPB). An isolation of the secondary containment and actuation of the SGT System are initiated in order to minimize the potential of an offsite dose release. The isolation on high drywell pressure supports actions to ensure that any offsite releases are within the limits calculated in the safety analysis. However, the Drywell Pressure-High Function associated with (continued)
SUSQUEHANNA - UNIT 2 B3.3-183 Revision 2
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY Secondary Containment Isolation Instrumentation B 3.3.6.2 3, 4. 5. 6. 7 Refuel Floor High Exhaust Duct. Refuel Floor Wall Exhaust Duct. and Railroad Access Shaft Exhaust Duct Radiation-High (continued)
The Exhaust Radiation-High signals are initiated from radiation detectors that are located on the ventilation exhaust ductwork coming from the refueling floor zones and the Railroad Access Shaft. The signal from each detector is input to an individual monitor whose trip outputs are assigned to an isolation channel. Eight channels of Refuel Floor High Exhaust Duct and Wall Exhaust Duct Radiation-High Function (four from Unit 1 and four from Unit 2) and two channels of Railroad Access Shaft Exhaust Duct Radiation - High Function (both from Unit 1) are available to ensure that no single instrument failure can preclude the isolation function.
Operability of the Unit 1 and Unit 2 Refuel Floor High Exhaust Duct Radiation Instrumentation and the Unit 1 and Unit 2 Refuel Floor Wall Exhaust Duct Radiation Instrumentation does not require HVAC system airflow in the ductwork.
The Allowable Values are chosen to promptly detect gross failure of the fuel cladding.
The Refuel Floor Exhaust Radiation-High Functions are required to be OPERABLE during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, because the capability of detecting radiation releases due to fuel failures (due to a fuel handling accident) must be provided to ensure that offsite and control room dose limits are not exceeded.
The Railroad Access Shaft Exhaust Duct Radiation - High Function is only required to be OPERABLE during handling of irradiated fuel within the Railroad Access Shaft, and directly above the Railroad Access Shaft with the Railroad Access Shaft Equipment Hatch open. This provides the capability of detecting radiation releases due to fuel failures resulting from dropped fuel assemblies which ensures that offsite and control room dose limits are not exceeded.
Refuel Floor High and Wall Exhaust Duct and Railroad Access Shaft Exhaust Duct Radiation - High Functions will isolate Zone Ill of secondary containment.
(continued)
SUSQUEHANNA - UNIT 2 B3.3-185 Revision 4
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
ACTIONS
- 8. Manual Initiation Secondary Containment Isolation Instrumentation B 3.3.6.2 A Manual Initiation can be performed for secondary containment isolation by initiating a Primary Containment Isolation. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for the overall redundancy and diversity of the secondary containment isolation instrumentation as required by the NRC approved licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function, since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of Manual Initiation Function are available and are required to be OPERABLE in MODES 1, 2, and 3, and during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment. These are the MODES and other specified conditions in which the Secondary Containment Isolation automatic Functions are required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to secondary containment isolation instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate entry into the Condition. Section 1.3 also specifies that Required Actions of the Condition continue to apply for each additional failure, with Completion Times based on initial entry into the Condition. However, the Required Actions for inoperable secondary containment isolation instrumentation channels provide appropriate compensatory measures for separate inoperable channels. As such, a Note has been provided that allows separate Condition entry for each inoperable secondary containment isolation instrumentation channel.
(continued)
SUSQUEHANNA - UNIT 2 B3.3-186 Revision 4-
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY (continued)
CREOAS System Instrumentation B 3.3.7.1 function in harsh environments as defined by 10 CFR 50.49) are accounted for.
The specific Applicable Safety Analyses, LCO, and Applicability discussions are listed below on a Function by Function basis.
- 1. Reactor Vessel Water Level-Low Low. Level 2 Low reactor pressure vessel (RPV) water level indicates that the capability of cooling the fuel may be threatened. A low reactor vessel water level could indicate a LOCA and will automatically initiate the CREOAS System, since this could be a precursor to a potential radiation release and subsequent radiation exposure to control room personnel.
Reactor Vessel Water Level-Low Low, Level 2 signals are initiated from four level instruments that sense the difference between the pressure due to a constant column of water (reference leg) and the pressure due to the actual water level (variable leg) in the vessel. Four channels of Reactor Vessel Water Level-Low Low, Level 2 Function are available (two channels per trip system) and are required to be OPERABLE to ensure that no single instrument failure can preclude a CREOAS System initiation. The Reactor Vessel Water Level -Low Low, Level 2 Allowable Value was chosen to be the same as the HPCI and RCIC Reactor Vessel Water Level-Low Low Low, Level 1 Allowable Value (LCO 3.3.5.1, "ECCS Instrumentation and LCO 3.3.5..a-l_"RCIC Instrumentation").
The Reactor Vessel Water Level-Low Low, Level 2 Function is required to be OPERABLE in MODES 1, 2, and 3, and during operations with a potential for draining the reactor vessel (OPDRVs) to ensure that the control room personnel are protected during a LOCA. In MODES 4 and 5 at times other than OPDRVs, the probability of a vessel draindovm event resulting in a release of radioactive material into the environment is minimal. In addition, adequate protection is performed by the Control Room Air Inlet Radiation-High Function. Therefore, this Function is not required in other MODES and specified conditions.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-194 Revision G
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY CREOAS System Instrumentation B 3.3.7.1
- 3. 4, 5, 6, 7 Refuel Floor High Exhaust Duct. Refuel Floor Wall Exhaust Duct and Railroad Access Shaft Exhaust Duct Radiation-High (continued)
Duct Radiation-High Function (four from Unit 1 and four from Unit 2), and two channels of the Railroad Access Shaft Exhaust Radiation - High Function (both from Unit 1) are available and are required to be OPERABLE when the associated Refuel Floor Exhaust System is in operation to ensure that no single instrument failure can preclude the initiation function.
The Allowable Values are chosen to promptly detect gross failure of the fuel cladding. The Refuel Floor Exhaust Duct and Wall Exhaust Duct Radiation-High are required to be OPERABLE during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, because the capability of detecting radiation releases due to fuel failures ~due to fuel uncovery or dropped fuel assemblies) must be provided to ensure that offsite and control room dose limits are not exceeded.
The Railroad Access Shaft Exhaust Duct Radiation - High Function is only required to be OPERABLE during handling of irradiated fuel within the Railroad Access Shaft, and directly above the Railroad Access Shaft with the Railroad Access Shaft Equipment Hatch open, because the capability of detecting radiation releases due to fuel failures ~dropped fuel assemblies) must be provided to ensure that offsite and control room dose limits are not exceeded.
- 8. Main Control Room Outside Air Intake Radiation-High The main control room outside air intake radiation monitors measure radiation levels at the control structure outside air intake duct. A high radiation level may pose a threat to main control room personnel; thus, automatically initiating the CREOAS System. The Control Room Air Inlet Radiation-High Function consists of two independent monitors. Two channels of Control Room Air Inlet Radiation-High are available and are required to be OPERABLE to ensure that no single instrument failure can preclude CREOAS System initiation. The Allowable Value was selected to ensure protection of the control room personnel.
(continued)
SUSQUEHANNA - UNIT 2 B 3.3-196 Revision 2
BASES APPLICABLE SAFETY
- ANALYSES, LCO, and APPLICABILITY ACTIONS CREOAS System Instrumentation B 3.3.7.1
- 8. Main Control Room Outside Air Intake Radiation-High (continued)
The Control Room Air Inlet Radiation-High Function is required to be OPERABLE in MODES 1, 2, and 3 and during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment, to ensure that control room personnel are protected during a LOCA_Q[, fuel handling event, or vessel draindown event. During MODES 4 and 5, when these specified conditions are not in progress (e.g., CORE ALTERATIONS), the probability of a LOCA or fuel damage is low; thus, the Function is not required.
- 9. Manual Initiation A Manual Initiation can be performed for CREOAS isolation by initiating a Primary Containment Isolation. There is no specific FSAR safety analysis that takes credit for this Function. It is retained for the overall redundancy and diversity of the secondary containment isolation instrumentation as required by the NRC approved licensing basis.
There are two push buttons for the logic, one manual initiation push button per trip system. There is no Allowable Value for this Function, since the channels are mechanically actuated based solely on the position of the push buttons.
Two channels of Manual Initiation Function are available and are required to be OPERABLE in MODES 1, 2, and 3, and during CORE AL TERA TIONS, OPDRVs, and movement of irradiated fuel assemblies in the secondary containment. These are the MODES and other specified conditions in which the Secondary Containment Isolation automatic Functions are required to be OPERABLE.
A Note has been provided to modify the ACTIONS related to CREOAS System instrumentation channels. Section 1.3, Completion Times, specifies that once a Condition has been entered, subsequent divisions, subsystems, components, or variables expressed in the Condition, discovered to be inoperable or not within limits, will not result in separate (continued)
SUSQUEHANNA - UNIT 2 B3.3-197 Revision Q
B 3.5 B 3.5.1 BASES ECCS-Operating B 3.5.1 EMERGENCY CORE COOLING SYSTEMS (ECCS).,. REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM ECCS-Operating BACKGROUND The ECCS is designed, in conjunction with the primary and secondary containment, to limit the release of radioactive materials to the environment following a loss of coolant accident (LOCA). The ECCS uses two independent methods (flooding and spraying) to cool the core during a LOCA. The ECCS network consists of the High Pressure Coolant Injection (HPCI) System, the Core Spray (CS) System, the low pressure coolant injection (LPCI) mode of the Residual Heat Removal (RHR) System, and the Automatic Depressurization System (ADS). The suppression pool provides the required source of water for the ECCS. Although no credit is taken in the safety analyses for the condensate storage tank (CST), it is capable of providing a source of water for the HPCI and CS systems.
On receipt of an initiation signal, ECCS pumps automatically start; simultaneously, the system aligns and the pumps inject water, taken either from the CST or suppression pool, into the Reactor Coolant System (RCS) as RCS pressure is overcome by the discharge pressure of the ECCS pumps. Although the system is initiated, ADS action is delayed, allowing the operator to interrupt the timed sequence if the system is not needed. The HPCI pump discharge pressure quickly exceeds that of the RCS, and the pump injects coolant into the vessel to cool the core. If the break is small, the HPCI System will maintain coolant inventory as well as vessel level while the RCS is still pressurized. If HPCI fails, it is backed up by ADS in combination with LPCI and CS. In this event absent operator action, the ADS timed sequence would time out and open the selected safety/relief valves (S/RVs) depressurizing the RCS, thus allowing the LPCI and CS to overcome RCS pressure and inject coolant into the vessel. If the break is large, RCS pressure initially drops rapidly and the LPCI and CS cool the core.
Water from the break returns to the suppression pool where it is used again and again. Water in the suppression pool is circulated through a heat exchanger cooled by the RHR Service Water System. Depending on the location and size of the break, portions of the ECCS may be ineffective; (continued)
SUSQUEHANNA - UNIT 2 B 3.5-1 Revision-+
BASES APPLICABILITY ACTIONS ECCS-Operating B 3.5.1 All ECCS subsystems are required to be OPERABLE during MODES 1, 2, and 3, when there is considerable energy in the reactor core and core cooling would be required to prevent fuel damage in the event of a break in the primary system piping. In MODES 2 and 3, when reactor steam dome pressure is :::; 150 psig, ADS and HPCI are not required to be OPERABLE because the low pressure ECCS subsystems can provide sufficient flow below this pressure. EGGS rB equirements for MODES 4 and 5 are specified in LCO 3.5.2, EGGS Shutdown Reactor Pressure Vessel (RPV) Water Inventory Control."
A Note prohibits the application of LCO 3.0.4.b to an inoperable HPCI subsystem. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable HPCI subsystem and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
If any one low pressure ECCS injection/spray subsystem is inoperable for reasons other than Condition B, the inoperable subsystem must be restored to OPERABLE status within 7 days. In this Condition, the remaining OPERABLE subsystems provide adequate core cooling during a LOCA. However, overall ECCS reliability is reduced, because a single failure in one of the remaining OPERABLE subsystems, concurrent with a LOCA, may result in the ECCS not being able to perform its intended safety function. The 7 day Completion Time is based on a reliability study (Ref. 12) that evaluated the impact on ECCS availability, assuming various components and subsystems were taken out of service. The results were used to calculate the average availability of ECCS equipment needed to mitigate the consequences of a LOCA as a function of allowed outage times (i.e., Completion Times).
If one LPCI pump in one or both LPCI subsystems is inoperable, the inoperable LPCI pumps must be restored to OPERABLE status within 7 days. In this Condition, the remaining OPERABLE LPCI pumps and at least one CS subsystem provide adequate core cooling during a LOCA.
However, overall ECCS reliability is reduced, because a single failure in one of the remaining OPERABLE subsystems, concurrent with a LOCA, may result in the ECCS not being able to perform its intended safety function. A 7 day Completion Time is based on a reliability study cited in Reference 12 and has been found to be acceptable through operating experience.
(continued)
SUSQUEHANNA - UNIT 2 B 3.5-6 Revision 2:
B 3.5 B 3.5.2 BASES EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 EMERGENCY CORE COOLING SYSTEMS (ECCS).1 REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE ISOLATION COOLING (RCIC) SYSTEM Reactor Pressure Vessel (RPV) Water Inventory ControlECCS Shutdown BACKGROUND The RPV contains penetrations below the top of the active fuel (T AF) that have the potential to drain the reactor coolant inventory to below the TAF.
If the water level should drop below the T AF. the ability to remove decay heat is reduced. which could lead to elevated cladding temperatures and clad perforation. Safety Limit 2.1.1.3 requires the RPV water level to be above the top of the active irradiated fuel at all times to prevent such elevated cladding temperatures.A description of the Core Spray (CS)
System and the Low Pressure Coolant Injection (LPCI) mode of the Residual Heat Removal (RHR) System is provided in the Bases for LCO 3.5.1,
APPLICABLE SAFETY ANALYSES "EGGS Operating."
With the unit in MODE 4 or 5. RPV water inventory control is not required to mitigate any events or accidents evaluated in the safety analyses. RPV water inventory control is required in MODES 4 and 5 to protect Safety Limit 2.1.1.3 and the fuel cladding barrier to prevent the release of radioactive material to the environment should an unexpected draining event occur.
A double-ended guillotine break of the Reactor Coolant System (RCS) is not postulated in MODES 4 and 5 due to the reduced RCS pressure.
reduced piping stresses. and ductile piping systems. Instead. an event is considered in which single operator error or initiating event allows draining of the RPV water inventory through a single penetration flow path with the highest flow rate, or the sum of the drain rates through multiple penetration flow paths susceptible to a common mode failure (e.g., seismic event, loss of normal power. single human error).The EGGS performance is evaluated for the entire spectrum of break sizes for a postulated loss of coolant accident (LOCA). The long term cooling analysis following a design basis LOCA (Reference 1) demonstrates that only one low pressure EGGS injection /spray subsystem is required, post LOCA, to maintain adequate reactor vessel water level in the event of an inadvertent vessel draindo1.vn. It is reasonable to assumeg, based on engineering judgement, that while in MODES 4 and 5, one low pressure ECCS injection/spray subsystem can maintain adequate reactor vessel water level. To provide redundancy, a minimum of two low pressure EGGS injection/spray subsystems are required to be OPERABLE in MODES 4 and 5.
LCO As discussed in References 1, 2, 3, 4, and 5, operating experience has shown RPV water inventory to be significant to public health and safety.
Therefore. RPV Water Inventory Control satisfies Criterion 4 of 10 CFR 50.36(c)(2)(ii).The low pressure EGGS subsystems satisfy Criterion 3 of the NRG Policy Statement (Ref. 2).
The RPV water level must be controlled in MODES 4 and 5 to ensure that if an unexpected draining event should occur, the reactor coolant water level remains above the top of the active irradiated fuel as required by Safety Limit 2.1.1.3.
The Limiting Condition for Operation (LCO) requires the DRAIN TIME of RPV water inventory to the TAF to be ~ 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. A DRAIN TIME of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> is considered reasonable to identify and initiate action to mitigate unexpected draining of reactor coolant. An event that could cause loss of RPV water inventory and result in the RPV water level reaching the TAF in greater than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
Twe-One low pressure ECCS injection/spray subsystems ai=e-1§._required to be OPERABLE and capable of being manually started to provide defense-in-depth should an unexpected draining event occur. The-A low pressure ECCS injection/spray subsystems consist.§ of either twoone Core Spray (
CS} subsystems a.Mor twoone Low Pressure Coolant Injection {LPCll subsystems. Each CS subsystem consists of twE>-one motor driven pumps, piping, and valves to transfer water from the suppression pool or condensate storage tank (CST) to the reactor pressure vessel (RPV). Each LPCI subsystem consists of one of the PNO motor driven pumps, piping, and valves to transfer water from the suppression pool to the RPV. Only a single LPCI pump is required per subsystem because of the larger injection capacity in relation to a GS subsystem. In MODES 4 and 5, the RHR System cross tie valves are not required to be closed.
(continued)
SUSQUEHANNA - UNIT 2 B 3.5-19 Revision+
BASES LCO (continued)
APPLICABILITY EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 The LCO is modified by a Note which allows a required LPCI subsystems may be aligned for decay heat removal and to be considered OPERABLE during alignment and operation for decay heat removalfor the EGGS function, if they can beif capable of being manually realigned (remote or local) to the LPCI mode and ara-l§_not otherwise inoperable. Alignment and operation for decay heat removal includes when the required RHR pump is not operating or when the system is realigned from or to the RHR shutdown cooling mode. This allowance is necessary since the RHR System may be required to operate in the shutdown cooling mode to remove decay heat and sensible heat from the reactor. Because of the restrictions on ORAi N Tl ME, sufficient time will be available following an unexpected draining event to manually align and initiate LPCI subsystem operation to maintain RPV water inventory prior to the RPV water level reaching the TAF.low pressure and 101.v temperature conditions in MODES 4 and 5, sufficient time will be available to manually align and initiate LPCI subsystem operation to provide core cooling prior to postulated fuel uncovery.
RPV water inventory control is required in MODES 4 and 5. Requirements on water inventory control in other MODES are contained in LCOs in Section 3.3, Instrumentation. and other LCOs in Section 3.5, ECCS, RCIC, and RPV Water Inventory Control. RPV water inventory control is required to protect Safety Limit 2.1.1.3 which is applicable whenever irradiated fuel is in the reactor vessel. OPERABILITY of the low pressure EGGS injection/spray subsystems is required in MODES 4 and 5 to ensure adequate coolant inventory and sufficient heat removal capability for the irradiated fuel in the core in case of an inadvertent draindown of the vessel. Requirements for EGGS OPERABILITY during MODES 1, 2, and 3 are discussed in the Applicability section of the Bases for LCO 3.5.1. EGGS subsystems are not required to be OPERABLE during MODE 5 with the spent fuel storage pool gates removed and the water level maintained at ~22 ft. above the RPV flange. This provides sufficient coolant inventory to allow operator action to terminate the inventory loss prior to fuel uncover)' in case of an inadvertent draind0 1Nn.
The Automatic Depressurization System is not required to be OPERABLE to be OPERABLE during MODES 4 and 5 because the RPV pressure is
~ 150 psig, and the CS System and the LPCI subsystems can provide core cooling 1Nithout any depressurization of the primary system.
The High Pressure Coolant Injection System is not required to be OPERABLE during MODES 4 and 5 since the low pressure EGGS injection/spray subsystems can provide sufficient f101N to the vessel.
ACTIONS A.1 and B.1 If any onethe required low pressure ECCS injection/spray subsystem is inoperable, the inoperable subsystemn must be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. In this Condition, the LCO controls on DRAIN TIME minimize the possibility that an unexpected draining event could necessitate the use of the ECCS injection/spray subsystem, however the defense-in-depth provided by the ECCS injection/spray subsystem is lost. the remaining OPERABLE subsystem can provide sufficient vessel flooding capability to recover from an inadvertent (continued)
SUSQUEHANNA - UNIT 2 B 3.5-20 Revision 4-
BASES ACTIONS EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 A.1 and B.1 (continued)
Vessel draindo*Nn. Howe'ler, o'lerall system reliability is reduced because a single fuilure in the remaining OPERABLE subsystem concurrent with a vessel draindown could result in the EGGS not being able to perform its intended function. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time for restoring the required low pressure ECCS injection/spray subsystem to OPERABLE status is based on engineering judgement that consider.§.eG the LCO controls on DRAIN TIME the remaining a'lailable subsystem and the low probability of a 'lessel draindown an unexpected draining event that would result in loss of RPV water inventory.
WHA-!f_the inoperable ECCS injection/spray subsystem !.§._not restored to OPERABLE status within the required Completion Time, action must be initiated immediately initiated to establish a method of water injection capable of operating without offsite electrical power. The method of water injection includes the necessary instrumentation and controls, water sources, and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The method of water injection may be manually initiated and may consist of one or more systems or subsystems, and must be able to access water inventory capable of maintaining the RPV water level above the TAF for 2: 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. If recirculation of injected water would occur, it may be credited in determining the necessary water volume.suspend operations with a potential for draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindown and the subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
C.1, C.2, and C.3 With the DRAIN TIME less than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> but greater than or equal to 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, compensatory measures should be taken to ensure the ability to implement mitigating actions should an unexpected draining event occur.
Should a draining event lower the reactor coolant level to below the TAF, there is potential for damage to the reactor fuel cladding and release of radioactive material. Additional actions are taken to ensure that radioactive material will be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a controlled volume in which fission products can be contained, diluted, and processed prior to release to the environment. Required Action C.1 requires verification of the capability to establish the secondary containment boundary in less than the DRAIN TIME.
The required verification confirms actions to establish the secondary containment boundary are preplanned and necessary materials are available. The secondary containment boundary is considered established when one Standby Gas Treatment (SGT) subsystem is capable of maintaining a negative pressure in the secondary containment with respect to the environment. Verification that the secondary containment boundary can be established must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The required verification is an administrative activity and does not require manipulation or testing of equipment. Secondary containment penetration flow paths form a part of the secondary containment boundary. Required Action C.2 requires verification of the capability to isolate each secondary containment penetration flow path in less than the DRAIN TIME. The required verification confirms actions to isolate the secondary containment penetration flow paths are preplanned and necessary materials are available. Power operated valves are not required to receive automatic isolation signals if they can be closed manually within the required time. Verification that the secondary containment penetration flow paths can be isolated must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The required verification is an administrative activity and does not require manipulation or testing of equipment.
One SGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action C.3 requires verification of the capability to place one SGT subsystem in operation in less than the DRAIN TIME. The required verification confirms actions to place a SGT subsystem in operation are preplanned and necessary materials are available. Verification that a SGT subsystem can be placed in operation must be performed within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
The required verification is an administrative activity and does not require manipulation or testing of equipment.
D.1, D.2, D.3, and D.4 With the DRAIN TIME less than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. mitigating actions are implemented in case an unexpected draining event should occur. Note that if the DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, Required Action E.1 is also applicable.
Required Action D.1 requires immediate action to establish an additional method of water injection augmenting the ECCS injection/spray subsystem required by the LCO. The additional method of water injection includes the necessary instrumentation and controls, water sources. and pumps and valves needed to add water to the RPV or refueling cavity should an unexpected draining event occur. The Note to Required Action D.1 states that either the ECCS injection/spray subsystem or the additional method of water injection must be capable of operating without offsite electrical power.
The additional method of water injection may be manually initiated and may consist of one or more systems or subsystems. The additional method of water injection must be able to access water inventory capable of being injected to maintain the RPV water level above the TAF for ~ 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The additional method of water injection and the ECCS injection/spray subsystem may share all or part of the same water sources. If recirculation of injected water would occur, it may be credited in determining the required water volume.
Should a draining event lower the reactor coolant level to below the TAF, there is potential for damage to the reactor fuel cladding and release of radioactive material. Additional actions are taken to ensure that radioactive material will be contained, diluted, and processed prior to being released to the environment.
The secondary containment provides a control volume in which fission products can be contained, diluted, and processed prior to release to the environment. Required Action D.2 requires that actions be immediately initiated to establish the secondary containment boundary. With the secondary containment boundary established, one SGT subsystem is capable of maintaining a negative pressure in the secondary containment with respect to the environment.
The secondary containment penetrations form a part of the secondary containment boundary. Required Action D.3 requires that actions be immediately initiated to verify that each secondary containment penetration flow path is isolated or to verify that it can be manually isolated from the control room.
One SGT subsystem is capable of maintaining the secondary containment at a negative pressure with respect to the environment and filter gaseous releases. Required Action D.4 requires that actions be immediately initiated to verify that at least one SGT subsystem is capable of being placed in operation. The required verification is an administrative activity and does not require manipulation or testing of equipment.
E.1 If the Required Actions and associated Completion times of Conditions C or Dare not met or if the DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />, actions must be initiated immediately to restore the DRAIN TIME to~ 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. In this condition. there may be insufficient time to respond to an unexpected draining event to prevent the RPV water inventory from reaching the TAF.
Note that Required Actions D.1, D.2, D.3, and D.4 are also applicable when DRAIN TIME is less than 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br />.
C.1, C.2, 0.1, 0.2, and 0.3
'.Nith both of the required EGGS injection/spray subsystems inoperable, all coolant inventory makeup capability may be unavailable. Therefore, actions must immediately be initiated to suspend OPDRVs to minimize the probability of a vessel draindown and the subsequent potential for fission product release. Actions must continue until OPDRVs are suspended. One EGGS injection/spray subsystem must also be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
If at least one low pressure EGGS injection/spray subsystem is not restored to OPERABLE status within the 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time, additional actions are required to minimize any potential fission product release to the environment. This includes ensuring secondary containment is OPERABLE; one standby gas treatment subsystem is OPERABLE; and secondary containment isolation capability (i.e., one isolation *1al*1e and associated instrumentation are OPERABLE or other acceptable administrative controls to assure isolation capability) in each secondary containment penetration flow path not isolated and required to be isolated to mitigate radioactivity releases. OPERABILITY may be verified by an administrative check, or by examining logs or other information, to determine whether the components are out of (continued)
SUSQUEHANNA - UNIT 2 B 3.5-21 Revision 4-
BASES ACTIONS SURVEILLANCE REQUIREMENTS EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 C.1, C.2, D.1, D.2. and D.3 (continued}
service for maintenance or other reasons. It is not necessary to perform the Surveillances needed to demonstrate the OPERABILITY of the components.
If, however, any required component is inoperable, then it must be restored to OPERABLE status. In this case, the Surveillance may need to be performed to restore the component to OPERABLE status. Actions must continue until all required components are OPER,A,BLE.
The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time to restore at least one low pressure EGGS injection/spray subsystem to OPERABLE status ensures that prompt action
- 11ill be taken to provide the required cooling capacity or to initiate actions to place the plant in a condition that minimizes any potential fission product release to the environment.
SR 3.5.2.1 and SR 3.5.2.2 This Surveillance verifies that the DRAIN TIME of RPV water inventory to the TAF is ~ 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The period of 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> is considered reasonable to identify and initiate action to mitigate draining of reactor coolant. Loss of RPV water inventory that would result in the RPV water level reaching the T AF in greater than 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> does not represent a significant challenge to Safety Limit 2.1.1.3 and can be managed as part of normal plant operation.
The definition of DRAIN TIME states that realistic cross-sectional areas and drain rates are used in the calculation. A realistic drain rate may be determined using a single, step-wise. or integrated calculation considering the changing RPV water level during a draining event. For a Control Rod RPV penetration flow path with the Control Rod Drive Mechanism removed and not replaced with a blank flange, the realistic cross-sectional area is based on the control rod blade seated in the control rod guide tube. If the control rod blade will be raised from the penetration to adjust or verify seating of the blade, the exposed cross-sectional area of the RPV penetration flow path is used.
The definition of DRAIN TIME excludes from the calculation those penetration flow paths connected to an intact closed system, or isolated by manual or automatic valves that are locked, sealed. or otherwise secured in the closed position. blank flanges, or other devices that prevent flow of reactor coolant through the penetration flow paths. A blank flange or other bolted device must be connected with a sufficient number of bolts to prevent draining in the event of an Operating Basis Earthquake. Normal or expected leakage from closed systems or past isolation devices is permitted.
Determination that a system is intact and closed or isolated must consider the status of branch lines and ongoing plant maintenance and testing activities.
The Residual Heat Removal (RHR) Shutdown Cooling System is only considered an intact closed system when misalignment issues (Reference 6) have been precluded by functional valve interlocks or by isolation devices.
such that redirection of RPV water out of an RHR subsystem is precluded.
Further. RHR Shutdown Cooling System is only considered an intact closed system if its controls have not been transferred to Remote Shutdown, which disables the interlocks and isolation signals.
The exclusion of penetration flow paths from the determination of DRAIN TIME must consider the potential effects of a single operator error or initiating event on items supporting maintenance and testing (rigging, scaffolding, temporary shielding, piping plugs, snubber removal. freeze seals, etc.). If failure of such items could result and would cause a draining event from a closed system or between the RPV and the isolation device. the penetration flow path may not be excluded from the DRAIN TIME calculation.
Surveillance Requirement 3.0.1 requires SRs to be met between performances. Therefore. any changes in plant conditions that would change the DRAIN TIME requires that a new DRAIN TIME be determined.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.2 and SR 3.5.2.3 The minimum water level of 20 ft. 0 inches required for the suppression pool is periodically verified to ensure that the suppression pool will provide adequate net positive suction head (NPSH) for the CS System subsystem aREior LPCI subsystem pumps, recirculation volume, and vortex prevention.
With the suppression pool water level less than the required limit, the required ECCS injection/spray subsystem is inoperable unless aligned to an OPERABLE CST.all EGGS injection,tspray subsystems are inoperable unless they are aligned to an OPERABLE CST.
When suppression pool level is < 20 ft. 0 inches, ti he required CS System is considered OPEABLE GAty-if it can take suction from the CST, and the CST water level is sufficient to provide the required NPSH for the CS pump. Therefore, a verification that either the suppression pool water level is ~ 20 ft. 0 inches or that a required CS subsystem is aligned to take suction from the CST and the CST contains ~ 135,000 gallons of water, equivalent to 49% of capacity, ensures that the CS Subsystem can supply at least 135,000 gallons of makeup water to the RPV. Ho1Never, as noted, only one required CS subsystem may take credit for the CST option during OPDRVs. During OPDRVs, the volume in the CST may not provide adequate makeup if the RPV were completely drained. Therefore, only one CS subsystem is allowed to use the CST. This ensures (continued)
SUSQUEHANNA - UNIT 2 B 3.5-22 Revision~
BASES SURVEILLANCE REQUIREMENTS EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 SR 3.5.2A-2 and SR 3. 5. 2.~l_(continued) the other required EGGS subsystem has adequate makeup volume.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.4 The flow path piping has the potential to develop voids and pockets of entrained air. Maintaining the pump discharge lines of the required ECCS injection/spray subsystems full of water ensures that the ECCS subsystem will perform properly. This may also prevent a water hammer following an ECCS initiation signal. One acceptable method of ensuring that the lines are full is to vent at the high points.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.3, SR 3.5.2.5, SR 3.5.2.6, and SR 3.5.2.7 The Bases provided for SR 3.5.1.1, SR 3.5.1.7, SR 3.5.1.10, and SR 3.5.1.13 are applicable to SR 3.5.2.3, SR 3.5.2.5, SR 3.5.2.6 and SR 3.5.2.7, respectively.
SR 3.5.2.45 Verifying the correct alignment for manual, power operated, and automatic valves in the required ECCS subsystem flow paths provides assurance that the proper flow paths will 9*ist-be available for ECCS operation. This SR does not apply to valves that are locked, sealed, or otherwise secured in position, since these valves were verified to be in the correct position prior to locking, sealing, or securing. A valve that receives an initiation signal is allowed to be in a nonaccident position provided the valve will automatically reposition in the proper stroke time. This SR does not require any testing or valve manipulation; rather, it involves verification that those valves capable of potentially being mispositioned are in the correct position. This SR does not apply to valves that cannot be inadvertently misaligned, such as check valves. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
In MODES 4 and 5, the RHR System may operate in the shutdown cooling mode to remove decay heat and sensible heat from the reactor.
Therefore, RHR valves that are required for LPGI (continued)
SUSQUEHANNA - UNIT 2 B 3.5-23 Revision~
BASES EGGS ShutdownReactor Pressure Vessel (RPV) Water Inventory Control B 3.5.2 SURVEILLANCE SR 3.5.2.4 (oontinued)
REQUIREMENTS subsystem operation may be aligned f.or deoay heat removal. Theref.ore, this SR is modified by a Note that allows LPGI subsystems of the RHR System to be oonsidered OPERABLE f.or the EGGS funotion if all the required valves in the LPGI flmv path oan be manually realigned (remote or looal) to allow injeotion into the RPV, and the systems are not otherwise inoperable. This will ensure adequate sore oooling if an inadvertent RPV draindo*Nn should eG6Hf:
SR 3.5.2.6 Verifying that the required ECCS injection/spray subsystem can be manually started and operate for at least 1 O minutes demonstrates that the subsystem is available to mitigate a draining event. Testing the ECCS injection/spray subsystem through the recirculation line is necessary to avoid overfilling the refueling cavity. The minimum operating time of 10 minutes was based on engineering judgment.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.7 Verifying that each valve credited for automatically isolating a penetration flow path actuates to the isolation position on an actual or simulated RPV water level isolation signal is required to prevent RPV water inventory from dropping below the TAF should an unexpected draining event occur.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.5.2.8 The required ECCS subsystem is required to actuate on a manual initiation signal. This Surveillance verifies that a manual initiation signal will cause the required CS subsystem or LPCI subsystem to start and operate as designed.
including pump startup and actuation of all automatic valves to their required positions.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
REFER!;NCES This SR is modified by a Note that excludes vessel injection/spray during the Surveillance. Since all active components are testable and full flow can be demonstrated by recirculation through the test line. coolant injection into the RPV is not required during the Surveillance.
- 1. Information Notice 84-81 "Inadvertent Reduction in Primary Coolant Inventory in Boiling Water Reactors During Shutdown and Startup,"
November 1984.
- 2. Information Notice 86-74. "Reduction of Reactor Coolant Inventory Because of Misalignment of RHR Valves," August 1986.
- 3. Generic Letter 92-04, "Resolution of the Issues Related to Reactor Vessel Water Level Instrumentation in BWRs Pursuant to 10 CFR 50.54(f), "August 1992.
- 4. NRC Bulletin 93-03, "Resolution of Issues Related to Reactor Vessel Water Level Instrumentation in BWRs." May 1993.
- 5. Information Notice 94-52, "Inadvertent Containment Spray and Reactor Vessel Draindown at Millstone 1,"July 1994.
- 6. General Electric Service Information Letter No. 388. "RHR Valve Misalignment During Shutdown Cooling Operation for BWR 3/4/5/6,"
February 1983.
- 1.
FSAR, Section 6.3.2.
- 2.
Final Polic11 Statement on Technical Specifications Improvements.
July 22. 1993 (58 FR 39132).
SUSQUEHANNA - UNIT 2 B 3.5-24 Revision Q
B 3.5 B 3.5.3 BASES RCIC System B 3.5.3 EMERGENCY CORE COOLING SYSTEMS (ECCS).. REACTOR PRESSURE VESSEL (RPV) WATER INVENTORY CONTROL, AND REACTOR CORE
!SOLA TION COOLING (RCIC) SYSTEM RCIC System BACKGROUND The RCIC System is not part of the ECCS; however, the RCIC System is included with the ECCS section because of their similar functions.
The RCIC System is designed to operate either automatically or manually following reactor pressure vessel (RPV) isolation accompanied by a loss of coolant flow from the feedwater system to provide adequate core cooling and control of the RPV water level. Under these conditions, the High Pressure Coolant Injection (HPCI) and RCIC systems perform similar functions. The RCIC System design requirements ensure that the criteria of Reference 1 are satisfied.
The RCIC System (Ref. 2) consists of a steam driven turbine pump unit, piping, and valves to provide steam to the turbine, as well as piping and valves to transfer water from the suction source to the core via the feedwater system line, where the coolant is distributed within the RPV through the feedwater sparger. Suction piping is provided from the condensate storage tank (CST) and the suppression pool. Pump suction is normally aligned to the CST to minimize injection of suppression pool water into the RPV. However, if the CST water supply is low, an automatic transfer to the suppression pool water source ensures an adequate suction head for the pump and an uninterrupted water supply for continuous operation of the RCIC System. The steam to the turbine is piped from a main steam line upstream of the associated inboard main steam line isolation valve.
The RCIC System is designed to provide core cooling for a wide range of reactor pressures (165 psia to 1225 psia). Upon receipt of an initiation signal, the RCIC turbine accelerates to a specified speed. As the RCIC flow increases, the turbine control valve is automatically adjusted to maintain design flow. Exhaust steam from the RCIC turbine is discharged to the suppression pool. A full flow test line is provided to route water to the CST to allow testing of the RCIC System during normal operation without injecting water into the RPV.
(continued)
SUSQUEHANNA - UNIT 2 B 3.5-25 Revision BASES BACKGROUND (continued)
APPLICABLE SAFETY ANALYSES LCO APPLICABILITY ACTIONS RCIC System B 3.5.3 The RCIC pump is provided with a minimum flow bypass line, which discharges to the suppression pool. The valve in this line automatically opens to prevent pump damage due to overheating when other discharge line valves are closed. To ensure rapid delivery of water to the RPV and to minimize water hammer effects, the RCIC System discharge piping is kept full of water. The RCIC System is normally aligned to the CST. The RCIC discharge line is kept full of water using a "keep fill" system supplied by the condensate transfer system.
The function of the RCIC System is to respond to transient events by providing makeup coolant to the reactor. The RCIC System is not an Engineered Safety Feature System and no credit is taken in the safety analyses for RCIC System operation. Based on its contribution to the reduction of overall plant risk, however, the system is included in the Technical Specifications, as required by the NRC Policy Statement (Ref. 4).
The OPERABILITY of the RCIC System provides adequate core cooling such that actuation of any of the low pressure ECCS subsystems is not required in the event of RPV isolation accompanied by a loss of feedwater flow. The RCIC System has sufficient capacity for maintaining RPV inventory during an isolation event.
The RCIC System is required to be OPERABLE during MODE 1, and MODES 2 and 3 with reactor steam dome pressure >150 psig, since RCIC is the primary non-ECCS water source for core cooling when the reactor is isolated and pressurized. In MODES 2 and 3 with reactor steam dome pressure :::; 150 psig, the low pressure ECCS injection/spray subsystems can provide sufficient flow to the RPV. lnaflG..ffi MODES 4 and 5, RCIC is not required to be OPERABLE since RPV water inventory control is required by LCO 3.5.2. "Reactor Pressure Vessel (RPV) Water Inventory Control."the low pressure EGGS injection/spray subsystems can provide sufficient flow to the RPV.
A Note prohibits the application of LCO 3.0.4.b to an inoperable RCIC system. There is an increased risk associated with entering a MODE or other specified condition in the Applicability with an inoperable RCIC system and the provisions of LCO 3.0.4.b, which allow entry into a MODE or other specified condition in the Applicability with the LCO not met after performance of a risk assessment addressing inoperable systems and components, should not be applied in this circumstance.
(continued)
SUSQUEHANNA - UNIT 2 B 3.5-26 Revision J
BASES SURVEILLANCE REQUIREMENTS REFERENCES SR 3.5.3.5 RCIC System B 3.5.3 The RCIC System is required to actuate automatically in order to verify its design function satisfactorily. This Surveillance verifies that, with a required system initiation signal (actual or simulated), the automatic initiation logic of the RCIC System will cause the system to operate as designed, including actuation of the system throughout its emergency operating sequence; that is, automatic pump startup and actuation of all automatic valves to their required positions. This test also ensures the RCIC System will automatically restart on a n RPV low water level (Level 2) signal received subsequent to an RPV high water level (Level 8) trip and that the suction is automatically transferred from the CST to the suppression pool. The LOGIC SYSTEM FUNCTIONAL TEST performed in LCO 3. 3. 5.~~overlaps this Surveillance to provide complete testing of the assumed safety function.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
This SR is modified by a Note that excludes vessel injection during the Surveillance. Since all active components are testable and full flow can be demonstrated by recirculation through the test line, coolant injection into the RPV is not required during the Surveillance.
- 1.
10 CFR 50, Appendix A, GDC 33.
- 2.
FSAR, Section 5.4.6.
(continued)
SUSQUEHANNA - UNIT 2 B 3.5-30 Revision~
BASES APPLICABLE SAFETY ANALYSES SUSQUEHANNA - UNIT 2 PC I Vs B 3.6.1.3 The PCIVs LCO was derived from the assumptions related to minimizing the loss of reactor coolant inventory, and establishing the primary containment boundary during major accidents. As part of the primary containment boundary, PCIV OPERABILITY supports leak tightness of primary containment.
Therefore, the safety analysis of any event requiring isolation of primary containment is applicable to this LCO.
The DBAs that result in a release of radioactive material within primary containment are a LOCA and a main steam line break (MSLB). In the analysis for each of these accidents, it is assumed that PCIVs are either closed or close within the required isolation times following event initiation. This ensures that potential paths to the environment through PCIVs (including primary containment purge valves) and secondary containment bypass valves that are not PCIVs are minimized. The closure time of the main steam isolation valves (MSIVs) for a MSLB outside primary containment is a significant variable from a radiological standpoint. The MSIVs are required to close within 3 to 5 seconds since the 5 second closure time is assumed in the analysis. The safety analyses assume that the purge valves were closed at event initiation. Likewise, it is assumed that the primary containment is isolated such that release of fission products to the environment is controlled.
The OBA analysis assumes that within the required isolation time leakage is terminated, except for the maximum allowable leakage rate, La.
The single failure criterion required to be imposed in the conduct of unit safety analyses was considered in the original design of the primary containment purge valves. Two valves in series on each purge line provide assurance that both the supply and exhaust lines could be isolated even if a single failure occurred.
The primary containment purge valves may be unable to close in the environment following a LOCA. Therefore, each of the purge valves is required to remain closed during MODES 1, 2, and 3 except as permitted under the Note ~of SR 3.6.1.3.1. In this case, the single failure criterion remains applicable to the primary containment purge valve (continued)
B 3.6-16 Revision J
BASES LCO (continued)
APPLICABILITY SUSQUEHANNA - UNIT 2 PC IVs B 3.6.1.3 automatic isolation signal. The valves covered by this LCO are listed in Table B 3.6.1.3-1 and Table B 3.6.1.3-2.
The normally closed PCIVs, including secondary containment bypass valves listed in Table B 3.6.1.3-2 that are not PCIVs are considered OPERABLE when manual valves are closed or open in accordance with appropriate administrative controls, automatic valves are in their closed position, blind flanges are in place, and closed systems are intact. These passive isolation valves and devices are those listed in Table B 3.6.1.3-1.
Leak rate testing of the secondary containment bypass valves listed in Table 3.6.1.3-2 is permitted in Modes 1, 2 & 3 as described in the Primary Containment Leakage Rate Testing Program.
Purge valves with resilient seals, secondary containment bypass valves, including secondary containment bypass valves listed in Table B 3.6.1.3-2 that are not PCIVs, MSIVs, and hydrostatically tested valves must meet additional leakage rate requirements.
Other PCIV leakage rates are addressed by LCO 3.6.1.1, "Primary Containment," as Type B or C testing.
This LCO provides assurance that the PCIVs will perform their designed safety functions to minimize the loss of reactor coolant inventory and establish the primary containment boundary during accidents.
In MODES 1, 2, and 3, a OBA could cause a release of radioactive material to primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations of these MODES. Therefore, ffiGSt-PCIVs are not required to be (continued)
B 3.6-17a Revision 4
BASES APPLICABILITY (continued)
ACTIONS SUSQUEHANNA - UNIT 2 PC IVs B 3.6.1.3 OPERABLE and the primary containment purge valves are not required to be closed in MODES 4 and 5. Certain valves, however, are required to be OPERABLE to prevent inadvertent reactor vessel draindown. These valves are those whose associated instrumentation is required to be OPERABLE per LCO 3.3.6.1, "Primary Containment Isolation Instrumentation."
(This does not include the valves that isolate the associated instrumentation.)
The ACTIONS are modified by a Note allowing penetration flow path(s) to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator at the controls of the valve, who is in continuous communication with the control room. In this way, the penetration can be rapidly isolated when a need for primary containment isolation is indicated.
A second Note has been added to provide clarification that, for the purpose of this LCO, separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable PCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable PCIVs are governed by subsequent Condition entry and application of associated Required Actions.
The ACTIONS are modified by Notes 3 and 4. Note 3 ensures that appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable PCIV (e.g., an Emergency Core Cooling System subsystem is inoperable due to a failed open test return valve). Note 4 ensures appropriate remedial actions are taken when the primary containment leakage limits are exceeded. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, Notes 3 and 4 are added to require the proper actions be taken.
A.1 and A.2 With one or more penetration flow paths with one PCIV inoperable except for purge valve leakage not within limit, (continued)
B3.6-18 Revision -t
BASES ACTIONS (continued)
SUSQUEHANNA - UNIT 2 PC IVs B 3.6.1.3 With the secondary containment bypass leakage rate not within limit, the assumptions of the safety analysis may not be met.
Therefore, the leakage must be restored to within limit within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. Restoration can be accomplished by isolating the penetration that caused the limit to be exceeded by use of one closed and de-activated automatic valve, closed manual valve, or blind flange. When a penetration is isolated, the leakage rate for the isolated penetration is assumed to be the actual pathway leakage through the isolation device. If two isolation devices are used to isolate the penetration, the leakage rate is assumed to be the lesser actual pathway leakage of the two devices. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time is reasonable considering the time required to restore the leakage by isolating the penetration and the relative importance of secondary containment bypass leakage to the overall containment function.
F.1 In the event one or more containment purge valves are not within the purge valve leakage limits, purge valve leakage must be restored to within limits. The 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Completion Time is reasonable, considering that one containment purge valve remains closed, except as controlled by SR 3.6.1.3.1 so that a gross breach of containment does not exist.
G.1 and G.2 If any Required Action and associated Completion Time cannot be met in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued)
B 3.6-22 Revision~
BASES ACTIONS (continued)
SURVEILLANCE REQUIREMENTS SUSQUEHANNA - UNIT 2 H.1 and H.2 PC I Vs B 3.6.1.3 If any Required Action and associated Completion Time cannot be met, the unit must be placed in a condition in 1.vhich the LCO does not apply. If applicable, action must be immediately initiated to suspend operations with a potential for draining the reactor vessel (OPDRVs) to minimize the probability of a vessel draindown and subsequent potential for fission product release.
Actions must continue until OPDRVs are suspended or valve(s) are restored to OPERABLE status. If suspending an OP ORV would result in closing the residual heat removal (RHR) shutdown cooling isolation valves, an alternative Required Action is provided to immediately initiate action to restore the valve(s) to OPERABLE status. This allows RHR to remain in service *.vhile actions are being taken to restore the valve.
SR 3.6.1.3.1 This SR ensures that the primary containment purge valves are closed as required or, if open, open for an allowable reason. If a purge valve is open in violation of this SR, the valve is considered inoperable. If the inoperable valve is not otherwise known to have excessive leakage when closed, it is not considered to have leakage outside of limits. The SR is also modified by Note 1, stating that primary containment purge valves are only required to be closed in MODES 1, 2, and 3. If a LOCA inside primary containment occurs in these-MODES~
or 3, the purge valves may not be capable of closing before the pressure pulse affects systems downstream of the purge valves, or the release of radioactive material will exceed limits prior to the purge valves closing. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel), pressurization concerns are not present and the purge valves are allowed to be open. The SR is modified by.e_
Note 2--stating that the SR is not required to be met when the purge valves are open for the stated reasons. The Note states that these valves may be opened for inerting, de-inerting, pressure control, ALARA or air quality considerations for personnel entry, or Surveillances that require the valves to be open. The vent and purge valves are capable of closing in the environment following (continued)
B 3.6-23 Revision~
l
BASES SURVEILLANCE REQUIREMENTS SUSQUEHANNA - UNIT 2 SR 3.6.1.3.5 (continued)
PC I Vs B 3.6.1.3 OPERABILITY. MSIVs may be excluded from this SR since MSIV full closure isolation time is demonstrated by SR 3.6.1.3. 7.
The isolation time test ensures that the valve will isolate in a time period less than or equal to that assumed in the Final Safety Analyses Report. The isolation time and Frequency of this SR are in accordance with the requirements of the lnservice Testing Program.
SR 3.6.1.3.6 For primary containment purge valves with resilient seals, the Appendix J Leakage Rate Test Interval is sufficient. The acceptance criteria for these valves is defined in the Primary Containment Leakage Rate Testing Program, 5.5.12.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
The SR is modified by a Note stating that the primary containment purge valves are only required to meet leakage rate testing requirements in MODES 1, 2, and 3. If a LOCA inside primary containment occurs in tAese-MODES 1, 2, or 3, purge valve leakage must be minimized to ensure offsite radiological release is within limits. At other times when the purge valves are required to be capable of closing (e.g., during handling of irradiated fuel), pressurization concerns are not present and the purge valves are not required to meet any specific leakage criteria.
SR 3.6.1.3. 7 Verifying that the isolation time of each MSIV is within the specified limits is required to demonstrate OPERABILITY. The isolation time test ensures that the MSIV will isolate in a time period that does not exceed the times assumed in the OBA analyses. This ensures that the calculated radiological consequences of these events remain within regulatory limits.
(continued)
B 3.6-26 Revision 4
BASES SURVEILLANCE REQUIREMENTS SR 3.6.1.3.9 (continued)
PC IVs B 3.6.1.3 detected at the earliest possible time. EFCV failures will be evaluated to determine if additional testing in that test interval is warranted to ensure overall reliability and that failures to isolate are very infrequent.
Therefore, testing of a representative sample was concluded to be acceptable from a reliability standpoint (Reference 7).
SR 3.6.1.3.10 The TIP shear isolation valves are actuated by explosive charges. An in place functional test is not possible with this design. The explosive squib is removed and tested to provide assurance that the valves will actuate when required. The replacement charge for the explosive squib shall be from the same manufactured batch as the one fired or from another batch that has been certified by having one of the batch successfully fired. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.6.1.3.11 This SR ensures that the leakage rate of secondary containment bypass leakage paths is less than the specified leakage rate. This provides assurance that the assumptions in the radiological evaluations of Reference 4 are met. The secondary containment leakage pathways and Frequency are defined by the Primary Containment Leakage Rate Testing Program. This SR simply imposes additional acceptance criteria. A note is added to this SR, which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In tAe etAe!=-MODES other than 1. 2. or 3, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required.
SR 3.6.1.3.12 The analyses in References 1 and 4 are based on the specified leakage rate. Leakage through each MSIV must be ~ 100 scfh for anyone MSIV and ~ 300 scfh for total leakage through the MSIVs combined with the Main Steam Line Drain Isolation Valve, HPCI Steam Supply Isolation Valve and the RCIC Steam Supply Isolation Valve. The MSIVs can be tested at either~ Pt (24.3 psig) or Pa (48.6 psig). Main Steam Line Drain Isolation, HPCI and RCIC Steam Supply Line Isolation Valves, are tested at Pa (48.6 psig). A note is added to this SR, which states that these valves are only required to meet this leakage limit in MODES 1, 2, and 3. In the otherMODES other than 1. 2. or 3 (continued)
SUSQUEHANNA - UNIT 2 B 3.6-28 Revision g
BASES SURVEILLANCE REQUIREMENTS REFERENCES SUSQUEHANNA - UNIT 2 SR 3.6.1.3.12 (continued)
PC I Vs B 3.6.1.3 conditions, the Reactor Coolant System is not pressurized and specific primary containment leakage limits are not required. The Frequency is required by the Primary Containment Leakage Rate Testing Program.
SR 3.6.1.3.13 Surveillance of hydrostatically tested lines provides assurance that the calculation assumptions of Reference 2 are met. The acceptance criteria for the combined leakage of all hydrostatically tested lines is 3.3 gpm when tested at 1.1 Pa, (53.46 psig). The combined leakage rates must be demonstrated in accordance with the leakage rate test Frequency required by the Primary Containment Leakage Testing Program.
As noted in Table B 3.6.1.3-1, PCIVs associated with this SR are not Type C tested. Containment bypass leakage is prevented since the line terminates below the minimum water level in the suppression chamber. These valves are tested in accordance with the IST Program. Therefore, these valves leakage is not included as containment leakage.
This SR has been modified by a Note that states that these valves are only required to meet the combined leakage rate in MODES 1, 2, and 3, since this is when the Reactor Coolant System is pressurized and primary containment is required. In some instances, the valves are required to be capable of automatically closing during MODES other than MODES 1, 2, and 3. However, specific leakage limits are not applicable in these other MODES or conditions.
- 1.
FSAR, Chapter 15.
- 2.
Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
- 3.
10 CFR 50, Appendix J, Option B.
- 4.
FSAR, Section 6.2.
- 5.
NED0-30851-P-A, "Technical Specification Improvement Analyses for BWR Reactor Protection System," March 1988.
(continued)
B 3.6-29 Revision a
BASES (continued)
APPLICABLE SAFETY ANALYSES LCO APPLICABILITY ACTIONS Suppression Pool Water Level B 3.6.2.2 Initial suppression pool water level affects suppression pool temperature response calculations, calculated drywell pressure during vent clearing for a DBA, calculated pool swell loads for a DBA LOCA, and calculated loads due to S/RV discharges. Suppression pool water level must be maintained within the limits specified so that the safety analysis of Reference 1 remains valid.
Suppression pool water level satisfies Criteria 2 and 3 of the NRC Policy Statement. (Ref. 2)
A limit that suppression pool water level be ;::: 22 ft 0 inches and
- 24 ft 0 inches is required to ensure that the primary containment conditions assumed for the safety analyses are met. Either the high or low water level limits were used in the safety analyses, depending upon which is more conservative for a particular calculation.
In MODES 1, 2, and 3, a DBA would cause significant loads on the primary containment. In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES. The requirements for maintaining suppression pool water level within limits in MODE 4 or 5 is addressed in LCO 3.5.2, "Reactor Pressure Vessel (RPV) Water Inventory ControlECCS Shutdown."
With suppression pool water level outside the limits, the conditions assumed for the safety analyses are not met. If water level is below the minimum level, the pressure suppression function still exists as long as downcomers are covered, HPCI and RCIC turbine exhausts are covered, and S/RV quenchers are covered. If suppression pool water level is above the maximum level, protection against overpressurization still exists due to the margin in the peak containment pressure analysis and the capability of the Drywell Spray System. Therefore, continued operation for a (continued)
SUSQUEHANNA - UNIT 2 B 3.6-59 Revision G
BASES (continued)
APPLICABILITY Secondary Containment B 3.6.4.1 In MODES 1, 2, and 3, a LOCA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, secondary containment OPERABILITY is required during the same operating conditions that require primary containment OPERABILITY.
In MODES 4 and 5, the probability and consequences of the LOCA are reduced due to the pressure and temperature limitations in these MODES.
Therefore, maintaining secondary containment OPERABLE is not required in MODE 4 or 5 to ensure a control volume, except for other situations for which significant releases of radioactive material can be postulated, such as during operations with a potential for draining the reactor vessel (OPDRVs),
during CORE ALTERATIONS, or during movement of irradiated fuel assemblies in the secondary containment.
ACTIONS A.1 If secondary containment is inoperable, it must be restored to OPERABLE status within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining secondary containment during MODES 1, 2, and 3. This time period also ensures that the probability of an accident (requiring secondary containment OPERABILITY) occurring during periods where secondary containment is inoperable is minimal.
A temporary (one time) Completion Time is connected to the Completion Time Requirements above (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />) with an "OR" connector. The Temporary Completion Time is 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and applies to the replacement of the Reactor Building Recirculating Fan Damper Motors. The Temporary Completion Time of 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> may only be used once, and expires on December 31, 2005.
B.1 and B.2 If secondary containment cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
(continued)
SUSQUEHANNA - UNIT 2 B 3.6-85 Revision 4
BASES ACTIONS (continued)
C.1 and. C.2, and C.3 Secondary Containment B 3.6.4.1 Movement of irradiated fuel assemblies in the secondary containment, and CORE ALTERATIONS, and OPDRVs can be postulated to cause fission product release to the secondary containment. In such cases, the secondary containment is the only barrier to release of fission products to the environment. CORE ALTERATIONS and movement of irradiated fuel assemblies must be immediately suspended if the secondary containment is inoperable.
Suspension of these activities shall not preclude completing an action that involves moving a component to a safe position.
- A.Isa, action must be immediately initiated to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release.
Actions must continue until OPDRVs are suspended.
Required Action C.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.1.1 REQUIREMENTS This SR ensures that the secondary containment boundary is sufficiently leak tight to preclude exfiltration under expected wind conditions. Expected wind conditions are defined as sustained wind speeds of less than or equal to 16 mph at the 60m meteorological tower or less than or equal to 11 mph at the 1 Om meteorological tower if the 60m tower wind speed is not available.
Changes in indicated reactor building differential pressure observed during periods of short-term wind speed gusts above these sustained speeds do not by themselves impact secondary containment integrity. However, if secondary containment integrity is known to be compromised, the LCO must be entered regardless of wind speed.
(continued)
SUSQUEHANNA - UNIT 2 B 3.6-86 Revision~
SCI Vs B 3.6.4.2 BASES (continued)
APPLICABILITY In MODES 1, 2, and 3, a OBA could lead to a fission product release to the primary containment that leaks to the secondary containment. Therefore, the OPERABILITY of SCIVs is required.
ACTIONS In MODES 4 and 5, the probability and consequences of these events are reduced due to pressure and temperature limitations in these MODES.
Therefore, maintaining SCIVs OPERABLE is not required in MODE 4 or 5, except for other situations under which significant radioactive releases can be postulated, such as during operations with a potential f.or draining the reactor vessel (OPDRVs), during CORE ALTERATIONS, or during movement of irradiated fuel assemblies in the secondary containment. Moving irradiated fuel assemblies in the secondary containment may also occur in MODES 1, 2, and 3.
The ACTIONS are modified by three Notes. The first Note allows penetration flow paths to be unisolated intermittently under administrative controls. These controls consist of stationing a dedicated operator, who is in continuous communication with the control room, at the controls of the isolation device.
In this way, the penetration can be rapidly isolated when a need for secondary containment isolation is indicated.
The second Note provides clarification that for the purpose of this LCO separate Condition entry is allowed for each penetration flow path. This is acceptable, since the Required Actions for each Condition provide appropriate compensatory actions for each inoperable SCIV. Complying with the Required Actions may allow for continued operation, and subsequent inoperable SC IVs are governed by subsequent Condition entry and application of associated Required Actions.
The third Note ensures appropriate remedial actions are taken, if necessary, if the affected system(s) are rendered inoperable by an inoperable SCIV.
A.1 and A.2 In the event that there are one or more required penetration flow paths with one required SCIV inoperable, the affected penetration flow path(s) must be isolated. The method of isolation must include the use of at least one isolation barrier that cannot be adversely affected by a single active failure. Isolation barriers that meet this criterion are a closed and de-activated automatic SCIV, a closed manual valve, and a blind flange. For penetrations isolated in (continued)
SUSQUEHANNA - UNIT 2 B 3.6-92 Revision 2
BASES ACTIONS C.1 and C.2 (continued)
SC IVs B 3.6.4.2 valves are operated under administrative controls and the probability of their misalignment is low.
Condition C is modified by a Note indicating that this Condition is only applicable to penetration flow paths with only one SCIV. For penetration flow paths with two SCIVs, Conditions A and B provide the appropriate Required Actions.
Required Action C.2 is modified by a Note that applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative means. Allowing verification by administrative means is considered acceptable, since access to these areas is typically restricted.
Therefore, the probability of misalignment of these valves, once they have been verified to be in the proper position, is low.
D.1 and D.2 If any Required Action and associated Completion Time cannot be met, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
E.1 and. E.2. and E.3 If any Required Action and associated Completion Time are not met, the plant must be placed in a condition in which the LCO does not apply. If applicable, CORE ALTERATIONS and the movement of irradiated fuel assemblies in the secondary containment must be immediately suspended. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be immediately initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and the subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
(continued)
SUSQUEHANNA - UNIT 2 B 3.6-95 Revision +
BASES ACTIONS E.1, and E.2. and E.3 (continued)
SCI Vs B 3.6.4.2 Required Action E.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving fuel while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.2.1 REQUIREMENTS This SR verifies that each secondary containment manual isolation valve and blind flange that is required to be closed during accident conditions is closed. The SR helps to ensure that post accident leakage of radioactive fluids or gases outside of the secondary containment boundary is within design limits. This SR does not require any testing or valve manipulation.
Rather, it involves verification (typically visual) that those required SCIVs in secondary containment that are capable of being mispositioned are in the correct position.
The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
Two Notes have been added to this SR. The first Note applies to valves and blind flanges located in high radiation areas and allows them to be verified by use of administrative controls. Allowing verification by administrative controls is considered acceptable, since access to these areas is typically restricted during MODES 1, 2, and 3 for ALARA reasons. Therefore, the probability of misalignment of these SCIVs, once they have been verified to be in the proper position, is low.
A second Note has been included to clarify that SCIVs that are open under administrative controls are not required to meet the SR during the time the SCIVs are open.
(continued)
SUSQUEHANNA - UNIT 2 B 3.6-96 Revision~
BASES LCO (continued)
APPLICABILITY SGT System B 3.6.4.3 one SGT subsystem in the event of a single active failure. A SGT subsystem is considered OPERABLE when it has an OPERABLE set of dampers, filter train, one reactor building recirculation fan and associated dampers, and associated controls, including instrumentation. (The reactor building recirculation fans and associated dampers are not dedicated to either SGT subsystem. As a result, when any one reactor building recirculation division is not OPERABLE, one arbitrarily determined SGT subsystem is not operable. This interpretation only applies if both divisions of Secondary Containment Isolation logic are operable). This includes the components required for at least one of the two SGTS filter cooling modes.
In MODES 1, 2, and 3, a DBA could lead to a fission product release to primary containment that leaks to secondary containment. Therefore, SGT System OPERABILITY is required during these MODES.
In MODES 4 and 5, the probability and consequences of these events are reduced due to the pressure and temperature limitations in these MODES.
Therefore, maintaining the SGT System in OPERABLE status is not required in MODE 4 or 5, except for other situations under which significant releases of radioactive material can be postulated, such as during operations with a potential f.or draining the reactor vessel (OPDRVs), during CORE AL TERA TIONS, or during movement of irradiated fuel assemblies in the secondary containment.
ACTIONS A.1 With one SGT subsystem inoperable, the inoperable subsystem must be restored to OPERABLE status in 7 days. In this Condition, the remaining OPERABLE SGT subsystem is adequate to perform the required radioactivity release control function. However, the overall system reliability is reduced because a single failure in the OPERABLE subsystem could result in the radioactivity release control function not being adequately performed. The 7 day Completion Time is based on consideration of such factors as the availability of the OPERABLE redundant SGT System and the low probability of a DBA occurring during this period.
(continued)
SUSQUEHANNA - UNIT 2 B3.6-102 Revision 2
BASES ACTIONS (continued B.1 and B.2 SGT System B 3.6.4.3 If the SGT subsystem cannot be restored to OPERABLE status within the required Completion Time in MODE 1, 2, or 3, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
C.1, C.2.1. and C.2.2. and C.2.3 During movement of irradiated fuel assemblies, in the secondary containment_Qf; during CORE AL TERA TIONS, or during OPDRVs, when Required Action A.1 cannot be completed within the required Completion Time, the OPERABLE SGT filter train should immediately be placed in operation. This action ensures that the remaining filter train is OPERABLE, that no failures that could prevent automatic actuation have occurred, and that any other failure would be readily detected.
An alternative to Required Action C.1 is to immediately suspend activities that represent a potential for releasing radioactive material to the secondary containment, thus placing the plant in a condition that minimizes risk. If applicable, CORE ALTERATIONS and movement of irradiated fuel assemblies must immediately be suspended. Suspension of these activities must not preclude completion of movement of a component to a safe position. Also, if applicable, actions must immediately be initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
The Required Actions of Condition C have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
(continued)
SUSQUEHANNA - UNIT 2 B3.6-103 Revision 2
BASES SGT System B 3.6.4.3 ACTIONS D.1 (continued)
If both SGT subsystems are inoperable in MODE 1, 2, or 3, the SGT system may not be capable of supporting the required radioactivity release control function. The 4 hour4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> Completion Time provides a period of time to correct the problem that is commensurate with the importance of maintaining the SGT System contribution to secondary containment during MODES 1, 2, and 3. This time period also ensures that the probability of an accident (requiring SGT OPERABILITY) occurring during periods where SGT is inoperable is minimal.
A temporary (one time) Completion Time is connected to the Completion Time Requirements above (4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />) with an "OR" connector. The Temporary Completion Time is 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> and applies to the replacement of the Reactor Building Recirculating Fan Damper Motors. The Temporary Completion Time of 4 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> may only be used once, and expires on December 31, 2005.
E.1 and E.2 If at least one SGT subsystem cannot be restored to OPERABLE status within the required Completion Time, the plant must be brought to a MODE in which the LCO does not apply. To achieve this status, the plant must be brought to at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and to MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.
The allowed Completion Times are reasonable, based on operating experience, to reach the required plant conditions from full power conditions in an orderly manner and without challenging plant systems.
F.1 and, F.2, and F.3 When two SGT subsystems are inoperable, if applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in secondary containment must immediately be suspended. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must immediately be initiated to suspend OPDRVs in order to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until OPDRVs are suspended.
(continued)
SUSQUEHANNA - UNIT 2 B3.6-104 Revision J
BASES (continued)
ACTIONS F.11 and F.2, and F.3 (continued)
SGT System B 3.6.4.3 Required Action F.1 has been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, in either case, inability to suspend movement of irradiated fuel assemblies would not be a sufficient reason to require a reactor shutdown.
SURVEILLANCE SR 3.6.4.3. 1 REQUIREMENTS Operating each SGT filter train for ::?: 1 O continuous minutes with heaters on ensures that both filter train are OPERABLE and that all associated controls are functioning properly. It also ensures that blockage, fan or motor failure, or excessive vibration can be detected for corrective action. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
SR 3.6.4.3.2 This SR verifies that the required SGT filter testing is performed in accordance with the Ventilation Filter Testing Program (VFTP). The VFTP includes testing HEPA filter performance, charcoal adsorber efficiency, minimum system flow rate, and the physical properties of the activated charcoal (general use and following specific operations). Specific test frequencies and additional information are discussed in detail in the VFTP.
SR 3.6.4.3.3 This SR verifies that each SGT subsystem starts on receipt of an actual or simulated initiation signal. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
(continued)
SUSQUEHANNA - UNIT 2 B 3.6-105 Revision J
BASES LCO (continued)
APPLICABILITY CREOAS System B 3.7.3 The LCO is modified by a Note allowing the CRE boundary to be opened intermittently under administrative controls. This Note only applies to openings in the CRE boundary that can be rapidly restored to the design condition, such as doors, hatches, floor plugs, and access panels. For entry and exit through doors the administrative control of the opening is performed by the person(s) entering or exiting the area. For other openings, these controls should be proceduralized and consist of stationing a dedicated individual at the opening who is in continuous communication with the operators in the CRE. This individual will have a method to rapidly close the opening and to restore the CRE boundary to a condition equivalent to the design condition when a need for CRE isolation is indicated.
In MODES 1, 2, and 3, the CREOAS System must be OPERABLE to ensure that the CRE will remain habitable during and following a OBA, since the OBA could lead to a fission product release.
In MODES 4 and 5, the probability and consequences of a OBA are reduced because of the pressure and temperature limitations in these MODES. Therefore, maintaining the CREOAS System OPERABLE is not required in MODE 4 or 5, except for the following situations under which significant radioactive releases can be postulated:
- a.
During operations *11ith a potential for draining the reactor vessel (OPDRVs);
~gGuring CORE ALTERATIONS.;. and
~gGuring movement of irradiated fuel assemblies in the secondary containment.
(continued)
SUSQUEHANNA - UNIT 2 B 3.7-16 Revision 3
BASES ACTIONS (continued)
D.1, D.2.1, and D.2.2. and D.2.3 CREOAS System B 3.7.3 The Required Actions of Condition D are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require either an entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment...Q!:1 during CORE AL TERA TIONS, or during OPDRVs, if the inoperable CREOAS subsystem cannot be restored to OPERABLE status within the required Completion Time, the OPERABLE CREOAS subsystem may be placed in the pressurization/filtration mode. This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent automatic actuation will occur, and that any active failure will be readily detected.
An alternative to Required Action D.1 is to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the CRE. This places the unit in a condition that minimizes the accident risk.
If applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindovm and the subsequent potential for fission product release. Actions must continue until the OPDRVs are suspended.
If both CREOAS subsystems are inoperable in MODE 1, 2, or 3, for reasons other than an inoperable CRE boundary (i.e., Condition B) the CREOAS System may not be capable of performing the intended function and the unit is in a condition outside of the accident analyses. Therefore, LCO 3.0.3 must be entered immediately.
(continued)
SUSQUEHANNA - UNIT 2 B 3.7-18A Revision 4-
BASES ACTIONS (continued)
SURVEILLANCE REQUIREMENTS F.1 and, F.2, and F.3 CREOAS System B 3.7.3 The Required Actions of Condition F are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require either an entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment_Q.[1 during CORE AL TERA TIONS, or during OPDRVs, with two CREOAS subsystems inoperable or with one or more CREOAS subsystems inoperable due to an inoperable CRE boundary, action must be taken immediately to suspend activities that present a potential for releasing radioactivity that might require pressurization of the CRE. This places the unit in a condition that minimizes the accident risk.
If applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. If applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until the OPDR\\ls are suspended.
SR 3.7.3.1 This SR verifies that a CREOAS fan in a standby mode starts on demand from the control room and continues to operate with flow through the HEPA filters and charcoal adsorbers. Standby systems should be checked periodically to ensure that they start and function properly. As the environmental and normal operating conditions of this system are not severe, testing each subsystem once every month provides an adequate check on this system. Systems with heaters must be operated for 2". 15 continuous minutes with the heaters energized. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
(continued)
SUSQUEHANNA - UNIT 2 B 3.7-188 Revision 4-
BASES APPLICABLE SAFETY ANALYSES (continued)
LCO APPLICABILITY Control Room Floor Cooling System 8 3.7.4 The Control Room Floor Cooling System satisfies Criterion 3 of the NRC Policy Statement. (Ref. 2)
Two independent and redundant subsystems of the Control Room Floor Cooling System are required to be OPERABLE to ensure that at least one is available, assuming a single failure disables the other subsystem.
Total system failure could result in the equipment operating temperature exceeding limits.
The Control Room Floor Cooling System is considered OPERABLE when the individual components necessary to maintain the control room temperature are OPERABLE in both subsystems. These components include the cooling coils, fans, chillers, compressors, ductwork, dampers, and associated instrumentation and controls. The Control Room Floor Cooling System fans, ductwork, and dampers are also addressed by LCO 3.7.3, "Control Room Emergency Outside Air Supply System".
In MODE 1, 2, or 3, the Control Room Floor Cooling System must be OPERABLE to ensure that the control room temperature will not exceed equipment OPERABILITY limits following habitability envelope isolation.
In MODES 4 and 5, the probability and consequences of a Design Basis Accident are reduced due to the pressure and temperature limitations in these MODES. Therefore, maintaining the Control Room Floor Cooling System OPERABLE is not required in MODE 4 or 5, except fGf-tAe f.ollowing situations under which significant radioactive releases can be postulated:
- a.
During operations with a potential f.or draining the reactor vessel (OPDRVs);
~g uring CORE AL TERATION$7 and
~g uring movement of irradiated fuel assemblies in the secondary containment.
(continued)
SUSQUEHANNA - UNIT 2 B 3.7-20 Revision 4
BASES ACTIONS Control Room Floor Cooling System B 3.7.4 With one control room floor cooling subsystem inoperable, the inoperable control room floor cooling subsystem must be restored to OPERABLE status within 30 days. With the unit in this condition, the remaining OPERABLE control room floor cooling subsystem is adequate to perform the control room air conditioning function. However, the overall reliability is reduced because a single failure in the OPERABLE subsystem could result in loss of the control room air conditioning function. The 30 day Completion Time is based on the low probability of an event occurring requiring habitability envelope isolation, the consideration that the remaining subsystem can provide the required protection, and the availability of alternate safety and nonsafety cooling methods. Since nonsafety alternate cooling methods are available, this Action is less restrictive than 3.7.3, where an alternate method of maintaining the habitability envelope at a positive pressure is not available.
B.1 and B.2 In MODE 1, 2, or 3, if the inoperable control room floor cooling subsystem cannot be restored to OPERABLE status within the associated Completion Time, the unit must be placed in a MODE that minimizes risk. To achieve this status, the unit must be placed in at least MODE 3 within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in MODE 4 within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />. The allowed Completion Times are reasonable, based on operating experience, to reach the required unit conditions from full power conditions in an orderly manner and without challenging unit systems.
C.1, C.2.1, and C.2.2, and C.2.3 The Required Actions of Condition C are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations. Therefore, inability to suspend movement of irradiated fuel assemblies is not sufficient reason to require entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment...Qr, during CORE AL TERA TIONS, or during OPDRVs, if Required Action A.1 cannot be completed within the required Completion Time, the OPERABLE control room floor cooling subsystem may be (continued)
SUSQUEHANNA - UNIT 2 B 3.7-21 Revision-+
BASES ACTIONS Control Room Floor Cooling System B 3.7.4 C.1. C.2.1. and C.2.2. and C.2.3 (continued) placed immediately in operation. This action ensures that the remaining subsystem is OPERABLE, that no failures that would prevent actuation will occur, and that any active failure will be readily detected.
An alternative to Required Action C.1 is to immediately suspend activities that present a potential for releasing radioactivity that might require isolation of the habitability envelope. This places the unit in a condition that minimizes risk.
If applicable, CORE AL TERA TIONS and movement of irradiated fuel assemblies in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindown and subsequent potential for fission product release. Actions must continue until the OPDRVs are suspended.
If both control room floor cooling subsystems are inoperable in MODE 1, 2, or 3, the Control Room Floor Cooling System may not be capable of performing the intended function. Therefore, LCO 3.0.3 must be entered immediately.
E.1 and, E.2. and E.3 The Required Actions of Condition E are modified by a Note indicating that LCO 3.0.3 does not apply. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
Therefore, inability to suspend movement of irradiated fuel assemblies is not a sufficient reason to require entry into LCO 3.0.3 or a reactor shutdown in accordance with LCO 3.0.3.
During movement of irradiated fuel assemblies in the secondary containment..Q[, during CORE AL TERA TIONS, or during OPDRVs, with two control room floor cooling subsystems inoperable, action must be taken (continued)
SUSQUEHANNA - UNIT 2 B 3.7-22 Revision-+
BASES ACTIONS SURVEILLANCE REQUIREMENTS REFERENCES E.1 and, E.2. and E.3 (continued)
Control Room Floor Cooling System B 3.7.4 immediately to suspend activities that present a potential for releasing radioactivity that might require isolation of the habitability envelope. This places the unit in a condition that minimizes risk.
If applicable, CORE AL TE RATIONS and handling of irradiated fuel in the secondary containment must be suspended immediately. Suspension of these activities shall not preclude completion of movement of a component to a safe position. Also, if applicable, actions must be initiated immediately to suspend OPDRVs to minimize the probability of a vessel draindovm and subsequent potential f.or fission product release.
Actions must continue until the OPDRVs are suspended.
SR 3.7.4.1 This SR verifies that the heat removal capability of the system is sufficient to remove the control room heat load assumed in the safety analyses.
The SR consists of a combination of testing and calculation. The Surveillance Frequency is controlled under the Surveillance Frequency Control Program.
- 1. FSAR, Section 6.4
- 2. Final Policy Statement on Technical Specifications Improvements, July 22, 1993 (58 FR 39132).
SUSQUEHANNA - UNIT 2 B 3.7-23 Revision 2
AC Source-Shutdown B 3.8.2 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.2 AC Sources-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the AC sources is provided in the Bases for LCO 3.8.1,
"AC Sources-Operating."
The OPERABILITY of the minimum AC sources during MODES 4 and 5 and during movement of irradiated fuel assemblies ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate AC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of the vessel or a fuel handling accident.
In general, when the unit is shut down the Technical Specifications requirements ensure that the unit has the capability to mitigate the consequences of postulated accidents. However, assuming a single failure and concurrent loss of all offsite or loss of all onsite power is not required. The rationale for this is based on the fact that many Design Basis Accidents (DBAs) that are analyzed in MODES 1, 2, and 3 have no specific analyses in MODES 4 and 5. Worst case bounding events are deemed not credible in MODES 4 and 5 because the energy contained within the reactor pressure boundary, reactor coolant temperature and pressure, and corresponding stresses result in the probabilities of occurrences significantly reduced or eliminated, and minimal consequences. These deviations from DBA analysis assumptions and design requirements during shutdown conditions are allowed by the LCO for required systems.
The Safety Analysis for Unit 2 assumes the OPERABILITY of some equipment that receives power from Unit 1 AC Sources.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-39 Revision~
BASES (continued)
AC Source-Shutdown B 3.8.2 LCO One offsite circuit capable of supplying the onsite Class 1 E power distribution subsystem(s) of LCO 3.8.8, "Distribution Systems-Shutdown," ensures that all required loads are powered from offsite power. An OPERABLE DG, associated with a Distribution System Engineered Safeguards System (ESS) bus required OPERABLE by LCO 3.8.8, ensures that a diverse power source is available for providing electrical power support assuming a loss of the offsite circuit. Together, OPERABILITY of the required offsite circuit and DG ensures the availability of sufficient AC sources to operate the plant in a safe manner and to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and reactor vessel draindown).
The qualified offsite circuit(s) must be capable of maintaining rated frequency and voltage while connected to their respective ESS bus( es),
and of accepting required loads during an accident. Qualified offsite circuits are those that are described in the FSAR and are part of the licensing basis for the unit. An offsite circuit includes all breakers, transformers, switches, automatic tap changers, interrupting devices, cabling, and controls required to transmit power from the offsite transmission network to the onsite Class 1 E ESS bus or buses. The offsite circuit consists of the incoming breaker and disconnect to startup transformers (ST) No. 1 O and ST No. 20 and the respective circuit path including feeder breakers to the four 4.16 kV ESS buses (A, B, C and D) for both Unit 1 and Unit 2. A detailed description of the offsite power network and circuits to the onsite Class 1 E ESS buses is found in the FSAR, Section 8.2.
The required DG must be capable of starting, accelerating to rated speed and voltage, connecting to its respective ESS bus on detection of bus undervoltage, and capable of accepting required loads. This sequence must be accomplished within 1 O seconds. Each DG must also be capable of accepting required loads within the assumed loading sequence intervals, and must continue to operate until offsite power can be restored to the ESS buses. These capabilities are required to be met from a variety of initial conditions such as DG in standby with engine hot. Additional DG capabilities must be demonstrated to meet required Surveillances, e.g., capability of the DG to revert to standby (continued)
SUSQUEHANNA - UNIT 2 B 3.8-41 Revision Q
BASES LCO (continued)
APPLICABILITY ACTIONS AC Source-Shutdown B 3.8.2 status on an ECCS signal while operating in parallel test mode.
Proper sequencing of loads, including tripping of nonessential loads, is a required function for DG OPERABILITY. In addition, proper sequence operation is an integral part of offsite circuit OPERABILITY since its inoperability impacts the ability to start and maintain energized loads required OPERABLE by LCO 3.8.8.
The AC sources are required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment to provide assurance that:
- a.
Systems that provide core coolingproviding adequate coolant inventory makeup are available for the irradiated fuel assemblies in the core in case of an inadvertent draindown of the reactor vessel;
- b.
Systems needed to mitigate a fuel handling accident are available;
- c.
Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
AC power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.1.
The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. If moving irradiated fuel assemblies while in MODE 4 or 5, LCO 3.0.3 would not specify any action. If moving irradiated fuel assemblies while in MODE 1, 2, or 3, the fuel movement is independent of reactor operations.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-42 Revision G
BASES ACTIONS (continued)
AC Source-Shutdown B 3.8.2 With one or more required AC Sources (DGs or 4.16 kV ESS buses) inoperable, the remaining required sources may be capable of supporting sufficient required features (e.g., system, subsystem, divisions, component or device), to allow continuation of CORE AL TERA TIONS and, fuel movement, and operations with a potential for draining the reactor 'lessel. For example, if two or more 4 kV emergency buses are required per LCO 3.8.8, one 4.16 kV emergency bus with offsite power available may be capable of supporting sufficient required features.
Therefore, the option provided by Required Action A.1 to declare required features inoperable when not powered from an offsite source or not capable of being powered by the required DG recognizes that appropriate restrictions will be required by ACTIONS in the LCO for the affected feature(s).
If a DG is credited with meeting both Unit 2 LCO 3.8.2.b and Unit 2 LCO 3.8.2.d or an offsite circuit is credited with meeting both Unit 2 LCO 3.8.2.a and Unit 2 LCO 3.8.2.c, the AC Source may considered OPERABLE for meeting one of the requirements even if is considered inoperable for meeting the other.
A.2.1. and A.2.2. and A.2.3. and A.2.4 With one or more required AC Sources inoperable, the option exists in ACTION A.1 to declare all affected features inoperable. Since this option may involve undesired administrative efforts, the allowance for sufficiently conservative actions is made. With one or more required AC Sources inoperable, the minimum required diversity of AC power sources is not available. It is, therefore, required to suspend CORE AL TERA TIONS and, movement of irradiated fuel assemblies in the secondary containment, and activities that oould result in inadvertent draining of the reactor vessel.
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required AC sources and to continue this action until restoration is accomplished in (continued)
SUSQUEHANNA - UNIT 2 B 3.8-43 Revision G
BASES ACTIONS SURVEILLANCE REQUIREMENTS A.2.1. and A.2.2. and A.2.3. and A.2.4 AC Source-Shutdown B 3.8.2 (continued) order to provide the necessary AC power to the plant safety systems.
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required AC electrical power sources should be completed as quickly as possible in order to minimize the time during which the plant safety systems may be without sufficient power.
Because of the allowance provided by LCO 3.0.6, the Distribution System ACTIONS would not be entered even if all AC sources to it are inoperable, resulting in de-energization. Therefore, the Required Actions of Condition A have been modified by a Note to indicate that when Condition A is entered with no AC power to any required ESS bus, ACTIONS for LCO 3.8.8 must be immediately entered. This Note allows Condition A to provide requirements for the loss of the offsite circuit whether or not a 4.16 kV ESS bus is de-energized. LCO 3.8.8 provides the appropriate restrictions for the situation involving a de-energized 4.16 kV ESS bus.
SR 3.8.2.1 SR 3.8.2.1 requires the SRs from LCO 3.8.1 that are necessary for ensuring the OPERABILITY of the AC sources in other than MODES 1, 2, and 3. SR 3.8.1.8 is not required to be met since only one offsite circuit is required to be OPERABLE. SR 3.8.1.17 is not required to be met because the required OPERABLE DG(s) is not required to undergo periods of being synchronized to the offsite circuit. SR 3.8.1.20 is excepted because starting independence is not required with the DGs that are not required to be OPERABLE. Refer to the corresponding Bases for LCO 3.8.1 for a discussion of each SR.
This SR is modified by a Note that specified SRs must be met but are not required to be performed. The reason for the Note is to preclude requiring the OPERABLE DG(s) from being paralleled with the offsite power network or otherwise (continued)
SUSQUEHANNA - UNIT 2 B 3.8-44 Revision~
DC Sources-Shutdown B 3.8.5 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.5 DC Sources-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the DC sources is provided in the Bases for LCO 3.8.4, "DC Sources-Operating."
The initial conditions of Design Basis Accident and transient analyses in the FSAR, Chapter 6 (Ref. 1) and Chapter 15 (Ref. 2), assume that Engineered Safety Feature systems are OPERABLE. The DC electrical power system provides normal and emergency DC electrical power for the diesel generators (DGs), emergency auxiliaries, and control and switching during all MODES of operation.
The OPERABILITY of the DC subsystems is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum DC electrical power sources during MODES 4 and 5 and during movement of irradiated fuel assemblies ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate DC electrical power is provided to mitigate events postulated during shutdown, such as an inadvertent draindown of the vessel or a fuel handling accident.
LCO 3.8.5 is normally satisfied by maintaining the OPERABILITY of all Division I or all Division II DC sources listed in Table 3.8.4-1 and the Diesel Generator E battery bank. However, any combination of DC sources that maintain OPERABILITY of equipment required by Technical Specifications may be used to satisfy this LCO. The DC sources satisfy Criterion 3 of the NRC Policy Statement (Ref. 3).
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-70 Revision+
BASES (continued)
LCO APPLICABILITY DC Sources-Shutdown B 3.8.5 The DC electrical power subsystems are required to be OPERABLE as needed to support required DC distribution subsystems required OPERABLE by LCO 3.8.8, "Distribution Systems-Shutdown." This requirement ensures the availability of sufficient DC electrical power sources to operate the unit in a safe manner and to mitigate the consequences of postulated events during shutdown (e.g., fuel handling accidents and inadvertent reactor vessel draindoi.\\1n).
The DC electrical power subsystems consist of the following:
- a.
each Unit 2 and Unit 1 DC electrical power subsystem identified in Table 3.8.4-1 including a 125 volt or 250 volt DC battery bank in parallel with a battery charger and the corresponding control equipment and interconnecting cabling supplying power to the associated bus; and,
- b.
the Diesel Generator E DC electrical power subsystem identified in Table 3.8.4-1 including a 125 volt DC battery bank in parallel with a battery charger and the corresponding control equipment and interconnecting cabling supplying power to the associated bus.
The DC electrical power sources required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that:
- a.
Required features to provide core coolingadequate coolant inventory makeup are available for the irradiated fuel assemblies in the core in case of an inadvertent draindown of the reactor vessel;
- b.
Required features needed to mitigate a fuel handling accident are available;
- c.
Required features necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
The DC electrical power requirements for MODES 1, 2, and 3 are covered in LCO 3.8.4.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-71 Revision+
BASES (continued)
ACTIONS DC Sources-Shutdown B 3.8.5 The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. This is acceptable because LCO 3.0.3 would not specify any additional actions while in MODE 4 or 5 and moving irradiated fuel assemblies.
A.1. A.2.1. A.2.2. and A.2.3. and A.2.4 If more than one Unit 2 DC distribution subsystem is required according to LCO 3.8.8, the remaining operable Unit 2 DC subsystems may be capable of supporting sufficient required features to allow continuation of CORE ALTERATIONS and, fuel movement, and operations with a potential for draining the reactor vessel. Therefore, the option is provided to declare required features with associated DC power sources inoperable which ensures that appropriate restrictions are implemented in accordance with the affected system LCOs' ACTIONS.
In many instances, this option may involve undesired administrative efforts. Therefore, the allowance for sufficiently conservative actions is made (i.e., to suspend CORE ALTERATIONS and, movement of irradiated fuel assemblies, and any activities that could result in inadvertent draining of the reactor vessel). Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required Unit 2 DC electrical power subsystems and to continue this action until restoration is accomplished in order to provide the necessary DC electrical power to the plant safety systems.
The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required DC electrical power subsystems should be completed as quickly as possible in order to minimize the time during which the plant safety systems may be without sufficient power.
Condition A is modified by a Note that states that Condition A is not applicable to the DG E DC electrical power subsystem. Conditions B and C are applicable to an inoperable DG E DC electrical power subsystem.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-72 Revision 4
BASES ACTIONS (continued)
D.2.1 and, D.2.21 and D.2.3, and D.2.4 DC Sources-Shutdown B 3.8.5 In many instances, the option of declaring individual supported equipment inoperable may involve undesired administrative efforts. Therefore, the allowance for sufficiently conservative actions is made (i.e., to suspend CORE AL TERA TIONS and, movement of irradiated fuel assemblie&;-aAG any activities that could result in inadvertent draining of the reactor vessel). Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required Unit 1 DC electrical power subsystems and to continue this action until restoration is accomplished in order to provide the necessary DC electrical power to the plant safety systems.
D.3.1, 3.2.1. and D.3.2.2 The option to transfer required common loads to an OPERABLE Unit 2 DC electrical power subsystem ensures required power will be restored.
However, although the corresponding Unit 2 DC electrical power subsystems are evaluated for this condition, this violates a design commitment to maintain DC power separation between units. To minimize the time this condition exists, Required Action D.3.2 directs that power supply be restored to the corresponding Unit 1 DC electrical power subsystem, which restores power to the common loads, or requires that the Unit 1 and common loads are declared inoperable. The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> provides sufficient time to restore power and acknowledges the fact that the condition, although not consistent with design requirements, maintains all required safety systems available.
D.1, D.2.1, D.2.2, D.2.3, D.2.4, D.3.1, D.3.2.1, and D.3.2.2 The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required DC electrical power subsystems should be completed as quickly as possible in order to minimize the time during which the plant safety systems may be without sufficient power.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-74 Revision _J
Distribution Systems-Shutdown B 3.8.8 B 3.8 ELECTRICAL POWER SYSTEMS B 3.8.8 Distribution Systems-Shutdown BASES BACKGROUND APPLICABLE SAFETY ANALYSES A description of the AC and DC electrical power distribution system is provided in the Bases for LCO 3.8.7, "Distribution Systems-Operating."
The initial conditions of Design Basis Accident and transient analyses in the FSAR, Chapter 6 (Ref. 1) and Chapter 15 (Ref. 2), assume Engineered Safety Feature (ESF) systems are OPERABLE. The AC and DC electrical power distribution systems and the DG E DC electrical power distribution subsystem are designed to provide sufficient capacity, capability, redundancy, and reliability to ensure the availability of necessary power to ESF systems so that the fuel, Reactor Coolant System, and containment design limits are not exceeded.
The OPERABILITY of the AC and DC electrical power distribution system is consistent with the initial assumptions of the accident analyses and the requirements for the supported systems' OPERABILITY.
The OPERABILITY of the minimum AC and DC electrical power sources and associated power distribution subsystems during MODES 4 and 5, and during movement of irradiated fuel assemblies in the secondary containment ensures that:
- a.
The facility can be maintained in the shutdown or refueling condition for extended periods;
- b.
Sufficient instrumentation and control capability is available for monitoring and maintaining the unit status; and
- c.
Adequate power is provided to mitigate events postulated during shutdown, such as an inad*<<ertent draindown of the vessel or a fuel handling accident.
LCO 3.8.8 is normally satisfied by maintaining the OPERABILITY of all Division I or all Division II DC distribution subsystems listed in Table 3.8.7-1 and the (continued)
SUSQUEHANNA - UNIT 2 B 3.8-94 Revision Q
BASES APPLICABLE SAFETY ANALYSES (continued)
LCO APPLICABILITY Distribution Systems-Shutdown B 3.8.8 diesel generator E distribution subsystem. However, any combination of DC distribution subsystems that maintain OPERABILITY of equipment required by Technical Specifications may be used to satisfy this LCO.
The AC and DC electrical power distribution systems satisfy Criterion 3 of the NRC Policy Statement (Ref. 3).
Various combinations of subsystems, equipment, and components are required OPERABLE by other LCOs, depending on the specific plant condition. Implicit in those requirements is the required OPERABILITY of necessary support required features. This LCO explicitly requires energization of the portions of the electrical distribution system necessary to support OPERABILITY of Technical Specifications required systems, equipment, and components-both specifically addressed by their own LCO, and implicitly required by the definition of OPERABILITY.
Maintaining these portions of the distribution system energized ensures the availability of sufficient power to operate the plant in a safe manner to mitigate the consequences of postulated events during shutdown (e.g.,
fuel handling accidents and inadvertent reaotor vessel draindown). The AC and DC electrical distribution subsystem is only considered Inoperable when the subsystem is not energized to its proper voltage.
The AC and DC electrical power distribution subsystems required to be OPERABLE in MODES 4 and 5 and during movement of irradiated fuel assemblies in the secondary containment provide assurance that:
- a.
Systems that provide core coolingto pro*;ide adequate ooolant inventory makeup are available for the irradiated fuel in the sore in oase of an inadvertent draindown of the reaotor vessel;
- b.
Systems needed to mitigate a fuel handling accident are available; (continued)
SUSQUEHANNA - UNIT 2 B 3.8-95 Revision G
BASES APPLICABILITY (continued)
ACTIONS Distribution Systems-Shutdown B 3.8.8
- c.
Systems necessary to mitigate the effects of events that can lead to core damage during shutdown are available; and
- d.
Instrumentation and control capability is available for monitoring and maintaining the unit in a cold shutdown condition or refueling condition.
The AC, DC and DG E electrical power distribution subsystem requirements for MODES 1, 2, and 3 are covered in LCO 3.8.7.
The ACTIONS have been modified by a Note stating that LCO 3.0.3 is not applicable. This is acceptable because LCO 3.0.3 would not specify any additional Actions in MODE 4 or 5 moving irradiated Fuel assemblies.
The Unit 2 AC and DC subsystems remaining OPERABLE with one or more Unit 2 AC and DC power sources inoperable may be capable of supporting sufficient required features to allow continuation of CORE AL TERA TIONS and, fuel movement, and operations with a potential for draining the reactor vessel. Therefore, the option is provided to declare required features with associated power sources inoperable which ensures that appropriate restrictions are implemented in accordance with the affected system LCOs' ACTIONS.
Condition A is modified by a Note that states that Condition A is not applicable to the DG E DC electrical power subsystem. Conditions B and C are applicable to an inoperable DG E DC electrical power subsystem.
A.2.1. A.2.2. A.2.3. and A.2.4. and i\\.2.5 In many instances the option above may involve undesired administrative efforts. Therefore, the allowance for sufficiently conservative actions is made, (i.e., to suspend CORE ALTERATIONS and, movement of irradiated fuel assemblies in the secondary containment, and any activities that could result in inadvertent draining of the reactor vessel).
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-96 Revision Q
BASES ACTIONS A.2.1, A.2.2, A.2.3, and A.2.4, and A.2.5 Distribution Systems-Shutdown B 3.8.8 (continued)
Suspension of these activities shall not preclude completion of actions to establish a safe conservative condition. These actions minimize the probability of the occurrence of postulated events. It is further required to immediately initiate action to restore the required AC and DC electrical power distribution subsystems and to continue this action until restoration is accomplished in order to provide the necessary power to the plant safety systems.
Required Actions A.2.1 through A.2.4-;ido not adequately address the concerns relating to coolant circulation and heat removal. Pursuant to LCO 3.0.6, the RHR-SDC ACTIONS would not be entered. Therefore, Required Action A.2.~is provided to direct declaring RHR-SDC inoperable and not in operation, which results in taking all appropriate RHR-SDC ACTIONS.
Required Action A.2 is modified by a Note. The Note ensures that appropriate remedial actions are taken, if necessary, if a required ECCS subsystem is rendered inoperable by the lnoperability of the electrical distribution subsystem. Pursuant to LCO 3.0.6, these actions are not required even when the associated LCO is not met. Therefore, the Note is added to require the proper actions be taken.
A.3.1, A.3.2, A.3.3.1 and A.3.3.2 The option to transfer required common loads to an OPERABLE Unit 2 electrical power subsystem ensures power will be restored to required loads. To ensure any loads which are not transferred to the Unit 2 power distribution subsystem are compensated for, Required Action A.3.2, requires the required features to be declared inoperable. Although the corresponding Unit 2 electrical power subsystem is evaluated for this condition, this violates a design commitment to maintain power separation between units. To minimize the time this condition exists, Required Action A.3.3 directs that power supply be restored to the corresponding Unit 1 electrical power subsystem, which restores power to the common loads, or requires that the Unit 1 and common loads are declared inoperable. The Completion Time of 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> provides sufficient time to restore power and acknowledges (continued)
SUSQUEHANNA - UNIT 2 B 3.8-97 Revision G
BASES ACTIONS Distribution Systems-Shutdown B 3.8.8 A.3.1. A.3.2. A.3.3.1 and A.3.3.2 (continued) the fact that the condition, although not consistent with design requirements, maintains all required safety systems available.
A.1 ! A.2.1 I A.2.2, A.2.3, A.2.4, ~A.3.1 I A.3.2 A.3.3.1. and A.3.3.2 The Completion Time of immediately is consistent with the required times for actions requiring prompt attention. The restoration of the required distribution subsystems should be completed as quickly as possible in order to minimize the time the plant safety systems may be without power.
If Diesel Generator E is not aligned to the class 1 E distribution system, the only supported safety function is the ESW system. Therefore, if Diesel Generator E DC power distribution subsystem is not OPERABLE, actions are taken to either restore the battery to OPERABLE status or shutdown Diesel Generator E and close the associated ESW valves to ensure the OPERABILITY of the ESW system. The 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> limit is consistent with the allowed time for other inoperable DC sources and provides sufficient time to evaluate the condition of the battery and take the corrective actions.
If Diesel Generator E is aligned to the class 1 E distribution system, the loss of Diesel Generator E DC power distribution subsystem will result in the loss of a on-site Class 1 E subsystem source. Therefore, if Diesel Generator E DC power subsystem is not OPERABLE actions are taken to either restore the battery to OPERABLE status or declare Diesel Generator E inoperable and take Actions of LCO 3.8.2. The 2 hour2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> limit is consistent with the allowed time for other DC sources and provides sufficient time to evaluate the condition of the battery and take the necessary corrective actions.
(continued)
SUSQUEHANNA - UNIT 2 B 3.8-98 Revision G
l BASES APPLICABLE SAFETY ANALYSES (continued)
LCO lnservice Leak and Hydrostatic Testing Operation B3.10.1 In the unlikely event of a largeany primary system leak that could result in draining the RPV, the reactor vessel would rapidly depressurize, allo1Ning the low pressure core cooling systems to operate. The make-up capability of the low pressure coolant injection and core spray subsystems, as required in MODE 4 by LCO 3.5.2, "EGGS Shutdo1NnReactor Pressure Vessel (RPV)-Water Inventory Control," would be more than adequate to keep the core floodedthe RPV water level above the TAF under this low decay heat load condition. Small system leaks would be detected by leakage inspections before significant inventory loss occurred.
For the purposes of this test, the protection provided by normally required MODE 4 applicable LCOs, in addition to the secondary containment requirements required to be met by this Special Operations LCO, will ensure acceptable consequences during normal hydrostatic test conditions and during postulated accident conditions.
As described in LCO 3.0.7, compliance with Special Operations LCOs is optional, and therefore, no criteria of the NRC Policy Statement apply. Special Operations LCOs provide flexibility to perform certain operations by appropriately modifying requirements of other LCOs. A discussion of the criteria satisfied for the other LCOs is provided in their respective Bases.
As described in LCO 3.0.7, compliance with this Special Operations LCO is optional. Operation at reactor coolant temperatures > 200°F but~ 212°F can be in accordance with Table 1.1-1 for MODE 3 operation without meeting this Special Operations LCO or its ACTIONS. This option may be required due to plant conditions or PIT limits, however, which require testing at temperatures> 200°F, while the ASME inservice test itself requires the safety/relief valves to be gagged, preventing their OPERABILITY. Additionally, even with required minimum reactor coolant temperatures< 200°F, RCS temperatures may drift above 200°F during the performance of inservice leak and hydrostatic testing or during subsequent control rod scram time testing, which is typically performed in conjunction with inservice leak and hydrostatic testing. While this Special Operations LCO is provided for inservice leak and hydrostatic testing, and for scram time testing initiated in conjunction with an inservice leak or hydrostatic test, parallel performance of other tests and inspections is not precluded.
(continued)
SUSQUEHANNA - UNIT 2 B 3.10-3 Revision