Technical Requirements Manual Unit 2
ML21224A189
Person / Time
Site: Susquehanna Talen Energy icon.png
Issue date: 08/02/2021
From:
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML21224A189 (30)


Text

MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2021-11958 USER INFORMATION:

GERLACH*ROSEY M Address: NUCSA2 Phone#:

542-3194 EMPL#: 028401 CA#:

0363 TRANSMITTAL INFORMATION:

TO:

GERLACH*ROSEY M 08/03/2021 LOCATION:

USNRC FROM:

NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2)

Page 1

THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU.

HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL.

WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL.

TOOLS

~OM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF

-..irRRORS.

ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.

TRM2 - TECHNICAL REQUIREMENTS MANUAL UNIT 2 REMOVE MANUAL TABLE OF CONTENTS DATE: 07/26/2021 ADD MANUAL TABLE OF CONTENTS DATE: 08/02/2021 CATEGORY: DOCUMENTS TYPE: TRM2 of 2

ttU~.

U..) 1 L.UL..L ID:

TEXT 3.7.3.8 REMOVE:

REV: 14 ADD:

REV: 15 CATEGORY: DOCUMENTS TYPE: TRM2 ID:

TEXT 3.8.1 ADD:

REV: 4 REMOVE :

REV: 3 Page 2

ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS@ X3171 OR X3194 FOR ASSISTANCE.

UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES.

PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES.

FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX.

of 2

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 Table Of Contents Issue Date:

08/02/2021 Procedure Name Rev Issue Date Change ID Change Number TEXT LOES 99 01/03/2019

Title:

LIST OF EFFECTIVE SECTIONS r<Z~\\

./ ) ", *,/)

TEXT TOC

Title:

TABLE OF CONTENTS 27 03/05/2019

/,//' "-.,,.

,, / '>

  • V

',_ "-J,/ /',

' \\,//

TEXT 1.1 0

11/19/2002

Title:

USE AND APPLICATION DEFINITIONS

(", '"' / /

~

~ /'*',/

/'*

-,',/)

TEXT 2.1 1

02/04/2005 ""*:'*-.__, /_,

Title:

PLANT PROGRAMS AND SETPOINTS PLANT PROGRAMS,

~'./

( ("'\\ ' '*,/*

o 1,1-3*1*/io ~'4,_))

/,r, l "'-__,,,

TEXT-2.2 11

Title:

PLANT PROGRAMS AND SETPOINTS/INS~RUMENT TRIP SETPOINT TABLE

'-.'/----.

  1. '/... >....., *, /r-*.___"'_.J/

/ / ' \\,_

TEXT 3.0 8-:'...\\. * *..._03/Mf,,,2021

,,,*,:.,* '\\_ "

Title:

APPLICABILITY TECHNICAL-,REQT:JIREMENT FOR OPERATION (TRO) APPLICABILITY

' /

r~"' "v TEXT 3.1.1

'\\_ D---)* 11/09/2007

/'~'

....,.* ~"-

Title:

REACTIVITY CONTR0L SYS::r'EMS ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD r i v

INJECTION (A\\WS~AR~) INSTRUMENTATION

/---.....,'

'...._/

TEXT 3.1. 2

(/ ---/ ' -

0 11/19/2002

(

/\\

Title:

REACTI\\7iI1\\r CO¥T,ROL SYSTEMS CONTROL ROD DRIVE (CRD) HOUSING SUPPORT

,, ____.,.., j

"-, -.,.,..,__,,.,..,,,./

TEXT 3.1.3 5

12/18/2017

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION TEXT 3.1.4 1

10/12/2020

Title:

REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT 3.2.1 19 03/31/2021

Title:

CORE OPERATING LIMITS REPORT (COLR)

Page 1 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name :

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.3.1 0

11/19/2002

Title:

INSTRUMENTATION RADIATION MONITORING INSTRUMENTATION TEXT 3.3.2 3

03/31/2011

Title:

INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION TEXT 3.3.3 2

11/09/2007

Title:

INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION TEXT 3.3.4 11 07/21/2017

Title:

INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION TEXT 3.3.5 0

11/19/2002

Title:

INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK TEXT 3.3.6 5

03/05/2019

Title:

INSTRUMENTATION TRM ISOLATION ACTUATION INSTRUMENTATION TEXT 3.3.7 3

07/15/2021

Title:

INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT 3.3.8 1

10/22/2003

Title:

INTENTIONALLY LEFT BLANK TEXT 3.3.9 3

05/14/2009

Title:

INSTRUMENTATION LPRM UPSCALE ALARM INSTRUMENTATION TEXT 3.3.10 1

12/14/2004

Title:

INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS TEXT 3.3.11 1

10/22/2003

Title:

INSTRUMENTATION MVP ISOLATION INSTRUMENTATION TEXT 3.3.12 2

04/02/2019

Title:

WATER MONITORING INSTRUMENTATION Page 2 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.4.1 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY TEXT 3.4.2 1

04/16/2009

Title:

INTENTIONALLY LEFT BLANK TEXT 3.4.3 1

ll/09/2007

Title:

REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM (RCS)

TEXT 3.4.4 2

05/14/2009

Title:

REACTOR COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT 3.4.5 1

04/26/2006

Title:

REACTOR COOLANT SYSTEM REACTOR VESSEL MATERIALS TEXT 3.4.6 1

04/25/2013

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT 3.5.1 2

03/05/2019

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ADS MANUAL INHIBIT TEXT 3.5.2 2

03/05/2019

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ECCS RPV WATER INVENTORY CONTROL AND RCIC MONITORING INSTRUMENTATION TEXT 3.5.3 1

03/05/2019

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM LONG TERM NITROGEN SUPPLY TO ADS TEXT 3.6.1 0

ll/19/2002

Title:

CONTAINMENT VENTING OR PURGING TEXT 3.6.2 3

01/03/2019

Title:

SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION TEXT 3.6.3 0

ll/19/2002

Title:

CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION Page 3 of 15 Report Date: os/02/21

SSES MANUAL Manual Name:

TRM2 Manual Ti tlt:!: TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.6.4 0

11/19/2002

Title:

CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT 3.7.1 0

11/19/2002

Title:

PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW) SHUTDOWN TEXT 3.7.2 0

11/19/2002

Title:

PLANT SYSTEMS ULTIMATE HEAT SINK (URS) AND GROUND WATER LEVEL TEXT 3.7.3.1 6

02/13/2020

Title:

PLANT SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT 3.7.3.2 3

04/16/2009

Title:

PLANT SYSTEMS SPRAY AND SPRINKLER SYSTEMS TEXT 3.7.3.3 4

05/16/2016

Title:

PLANT SYSTEMS CO2 SYSTEMS TEXT 3.7.3.4 2

04/16/2009

Title:

PLANT SYSTEMS HALON SYSTEMS TEXT 3.7.3,5 2

04/i6/2009

Title:

PLANT SYSTEMS FIRE HQSE STATIONS TEXT 3.7.3.6 2

04/16/2009

Title:

PLANT SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT 3.7.3.7 1

04/26/2006

Title:

PLANT SYSTEMS FIRE RATED ASSEMBLIES TEXT 3.7.3.8 15 08/02/2021

Title:

PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION TEXT 3.7.4 1

04/26/2006

Title:

PLANT SYSTEMS SOLID RADWASTE SYSTEM Page 4 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.7.5.1 1

03/05/2015

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT 3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT 3.7.5.3 1

04/26/2006

Title:

PLANT SYSTEMS LIQUID HOLDUP TANKS TEXT 3.7.6 3

06/04/2012

Title:

PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION TEXT 3.7.7 2

09/05/2008

Title:

PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION TEXT 3.7.8 9

03/05/2015

Title:

PLANT SYSTEMS SNUBBERS TEXT 3.7.9 2

03/05/2019

Title:

PLANT SYSTEMS CONTROL STRUCTURE HVAC TEXT 3.7.10 2

04/29/2014

Title:

PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)

TEXT 3.7.11 2

11/01/2018

Title:

PLANT SYSTEMS TEXT 3.8.l 4

08/02/2021

Title:

ELECTRICAL POWER PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3. 8.* 2. 1 2

11/09/2007

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT 3.8.2.2 3

06/23/2021

Title:

ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION -

AUTOMATIC Page 5 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name::

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.8.3 4

01/28/2020

Title:

ELECTRICAL POWER DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT 3.8.4 1

02/04/2005

Title:

ELECTRICAL POWER 24 VDC ELECTRICAL SUBSYSTEM TEXT 3.8.5 1

11/14/2013

Title:

ELECTRICAL POWER DEGRADED VOLTAGE PROTECTION TEXT 3.8.6 3

03/05/2019

Title:

ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING TEXT 3.8.7 3

02/25/2021

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM TEXT 3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS DECAY TIME TEXT 3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS COMMUNICATIONS TEXT 3.9.3 1

03/12/2019

Title:

REFUELING OPERATIONS REFUELING PLATFORM TEXT 3.10.1 1

04/26/2006

Title:

MISCELLANEOUS SEALED SOURCE CONTAMINATION TEXT 3.10.2 1

04/09/2007

Title:

MISCELLANEOUS SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT 3.10.3 3

10/17/2019

Title:

MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT 3.10.4 2

04/17/2009

Title:

INTENTIONALLY LEFT BLANK Page 6 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3. 11. l. 1 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION TEXT 3. 11. l. 2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE TEXT 3.11.1.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS LIQUID WASTE TREATMENT SYSTEM TEXT 3. 11. l. 4 2

10/09/2012

Title:

RADIOACTIVE EFFLUENTS LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT 3.11.1.5 3

03/05/2015

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT 3.11.2.1 4

03/12/2019

Title:

RADIOACTIVE EFFLUENTS DOSE RATE TEXT 3.11.2.2 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

NOBLE GASES TEXT 3.11.2.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS DOSE -

IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM TEXT 3.11.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS GASEOUS RADWASTE TREATMENT SYSTEM TEXT 3.11.2.5 4

07/03/2013

Title:

RADIOACTIVE EFFLUENTS VENTILATION EXHAUST TREATMENT SYSTEM TEXT 3.11.2.6 8

07/21/2017

Title:

RADIOACTIVE EFFLUENTS RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT 3.11.3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS TOTAL DOSE Page 7 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual Titlei: TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 3.11.4.1 4

03/05/2015

Title:

RADIOACTIVE EFFLUENTS MONITORING PROGRAM TEXT 3.11.4.2 2

04/26/2006

Title:

RA~IOACTIVE EFFLUENTS LAND USE CENSUS TEXT 3. 11. 4. 3 1

04/26/2006

Title:

RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM TEXT 3.12.1 0

ll/19/2002

Title:

LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT 3.12.2 4

04/17/2008

Title:

LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS TEXT 3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENTS TEXT 4.1 0

09/27/2003

Title:

ADMINISTRATIVE CONTROLS ORGANIZATION TEXT 4.2 1

01/03/2019

Title:

ADMINISTRATIVE CONTROLS REPORTABLE EVENT ACTION TEXT 4.3 1

01/03/2019

Title:

ADMINISTRATIVE CONTROLS SAFETY LIMIT VIOLATION TEXT 4.4 1

12/18/2008

Title:

ADMINISTRATIVE CONTROLS PROCEDURES & PROGRAMS TEXT 4.5 1

07/01/2021

Title:

ADMINISTRATIVE CONTROLS REPORTING REQUIREMENTS TEXT 4.6 0

09/27/2003

Title:

ADMINISTRATIVE CONTROLS RADIATION PROTECTION PROGRAM Page 8 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT 4.7 0

09/27/2003

Title:

ADMINISTRATIVE CONTROLS TRAINING TEXT B3.0 7

03/18/2021

Title:

APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY TEXT B3.1.1 2

04/29/2014

Title:

REACTIVITY CONTROL SYSTEM BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION TEXT B3.l.2 0

11/19/2002

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT TEXT B3.l.3 4

12/18/2017

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD BLOCK INSTRUMENTATION TEXT B3.l.4 1

10/12/2020

Title:

REACTIVITY CONTROL SYSTEM BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK.VALVE TEXT B3.2.l 0

11/19/2002

Title:

CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)

TEXT B3.3.l 1

01/31/2014

Title:

INSTRUMENTATION BASES RADIATION MONITORING INSTRUMENTATION TEXT B3.3.2 2

03/31/2011

Title:

INSTRUMENTATION BASES SEISMIC MONITORING INSTRUMENTATION TEXT B3.3.3 2

11/09/2007

Title:

INSTRUMENTATION BASES METEOROLOGICAL MONITORING INSTRUMENTATION TEXT B3.3.4 7

07/21/2017

Title:

INSTRUMENTATION BASES TRM POST ACCIDENT MONITORING (PAM)

INSTRUMENTATION TEXT B3.3.5 2

11/09/2007

Title:

INSTRUMENTATION BASES THIS PAGE INTENTIONALLY LEFT BLANK Page 9 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name::

TRM2 Manual Ti tlE~: TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.3.6 6

03/05/2019

Title:

INSTRUMENTATION BASES TRM ISOLATION ACTUATION INSTRUMENTATION TEXT B3.3.7 3

07/15/2021

Title:

INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM TEXT B3.3.8 1

10/22/2003

Title:

INTENTIONALLY BLANK TEXT B3.3.9 4

01/03/2019

Title:

INSTRUMENTATION BASES LPRM UPSCALE ALARM INSTRUMENTATION TEXT B3.3.10 3

02/22/2012

Title:

INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS TEXTB3.3.11 1

10/22/2003'

Title:

INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION TEXT B3.3.12 1

04/02/2019

Title:

WATER MONITORING INSTRUMENTATION TEXT B3.4.l 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY TEXT.B3.4.2 1

04/16/2009 Title :-REACTOR COOLANT SYSTEM BASES STRUCTURAL INTEGRITY TEXT B3. 4. 3.

1 11/09/2007

Title:

REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR TEXT B3.4.4 1

01/03/2019

Title:

REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT TEXT B3.4.5 0

11/19/2002

Title:

REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS Page 10 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.4.6 2

01/03/2019

Title:

REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION TEXT B3.5.l 2

03/17/2020

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ADS MANUAL INHIBIT TEXT B3.5.2 2

03/05/2019

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ECCS RPV WATER INVENTORY CONTROL AND RCIC MONITORING INSTRUMENTATION TEXT B3.5.3 2

03/05/2019

Title:

ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM LONG TERM NITROGEN SUPPLY TO ADS TEXT B3.6.1 0

11/19/2002

Title:

CONTAINMENT BASES VENTING OR PURGING TEXT B3.6.2 0

11/19/2002

Title:

CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 1

04/19/2007

Title:

CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION TEXT B3.6.4 1

12/14/2004

Title:

CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES TEXT B3.7.1 0

11/19/2002

Title:

PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)

TEXT B3.7.2 0

. 11/19/2002

Title:

PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UHS) GROUND WATER LEVEL TEXT B3.7.3.1 4

02/16/2017

Title:

PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM TEXT B3.7.3.2 2

04/26/2006

Title:

PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS Page 11 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual TitlE3: TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.3.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES CO2 SYSTEMS TEXT B3.7.3.4 3

06/19/2019

Title:

PLANT SYSTEMS BASES HALON SYSTEMS TEXT B3.7.3.5 1

04/26/2006

Title:

PLANT SYSTEMS BASES FIRE HOSE STATIONS TEXT B3.7.3.6 1

04/26/2006

Title:

PLANT SYSTEMS BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES TEXT B3.7.3.7 0

11/19/2002

Title:

PLANT SYSTEMS BASES FIRE RATED ASSEMBLIES TEXT B3.7.3.8 3

09/27/2012

Title:

PLANT SYSTEMS BASES FIRE DETECTION INSTRUMENTATION TEXT B3.7.4 0

11/19/2002

Title:

PLANT SYSTEMS BASES SOLID RADWASTE SYSTEM TEXT B3.7.5.1 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR TEXT B3.7.5.2 0

11/19/2002

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE TEXT B3.7.5.3 0

11/19/2002

Title:

PLANT SYSTEMS BASES LIQUID HOLDUP TANKS TEXT B3.7.6 4

06/04/2013

Title:

PLANT SYSTEMS BASES ESSW PUMPHOUSE VENTILATION TEXT B3.7.7 2

01/31/2008

Title:

PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION Page 12 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.7.8 4

01/31/2014

Title:

PLANT SYSTEMS BASES SNUBBERS TEXT B3.7.9 3

03/05/2019

Title:

PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC TEXT B3.7.10 1

12/14/2004

Title:

PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS TEXT B3.7.11 3

11/01/2018

Title:

STRUCTURAL INTEGRITY TEXT B3.8.l 2

03/10/2010

Title:

ELECTRICAL POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT B3.8.2.l 0

11/19/2002

Title:

ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

CONTINUOUS TEXT B3.8.2.2 2

06/23/2021

Title:

ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV)

THERMAL OVERLOAD PROTECTION -

AUTOMATIC TEXT B3.8,3 0

11/19/2002

Title:

ELECTRICAL POWER BASES DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES TEXT B3.8.4 0

11/19/2002

Title:

ELECTRICAL POWER BASES *24 VDC ELECTRICAL POWER SUBSYSTEM TEXT B3.8.5 1

11/14/2013

Title:

ELECTRICAL POWER BASES DEGRADED VOLTAGE PROTECTION TEXT B3.8.6 4

03/05/2019

Title:

ELECTRICAL POWER BASES EMERGENCY SWITCHGEAR ROOM-COOLING TEXT B3.8.7 3

02/25/2021

Title:

BATTERY MAINTENANCE AND MONITORING PROGRAM Page 13 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual TitlE:: TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.9.1 0

11/19/2002

Title:

REFUELING OPERATIONS BASES DECAY TIME TEXT B3.9.2 0

11/19/2002

Title:

REFUELING OPERATIONS BASES COMMUNICATIONS TEXT B3.9.3 1

03/12/2019

Title:

REFUELING OPERATIONS BASES REFUELING PLATFORM TEXT B3.10.l 0

11/19/2002

Title:

MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION TEXT B3.10.2 1

04/10/2007

Title:

MISCELLANEOUS BASES SHUTDOWN MARGIN TEST RPS INSTRUMENTATION TEXT B3.10.3 2

10/17/2019

Title:

MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)

TEXT B3. 11. 1. 1 1

05/10/2016

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION TEXT B3.11.l.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS DOSE TEXT B3.ll.1.3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM TEXT B3.11.l.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION TEXT B3.11.l.5 0

11/19/2002

Title:

RfillIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION TEXT B3.ll.2.l 1

12/14/2004

Title:

RADIOACTIVE EFFLUENTS BASES DOSE RATE Page 14 of 15 Report Date: 08/02/21

SSES MANUAL Manual Name:

TRM2 Manual

Title:

TECHNICAL REQUIREMENTS MANUAL UNIT 2 TEXT B3.ll.2.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE -

NOBLE GASES TEXT B3.11. 2. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES DOSE~ IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATES FORM TEXT B3.11.2.4 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM TEXT B3.11. 2. 5 5

07/03/2013

Title:

RADIOACTIVE EFFLUENTS BASES VENTILATION EXHAUST TREATMENT SYSTEM TEXT B3.11.2.6 2

09/08/2016

Title:

RADIOACTIVE EFFLUENTS BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION TEXT B3. 11. 3 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES TOTAL DOSE TEXT B3.11. 4. 1 5

03/05/2015

Title:

RADIOACTIVE EFFLUENTS BASES MONITORING PROGRAM TEXT B3.11.4.2 0

11/19/2002

Title:

RADIOACTIVE EFFLUENTS BASES LAND USE CENSUS TEXT B3.11.4.3 0

11/19/2002*

Title:

RADIOACTIVE EFFLUENTS BASES INTERLABORATORY COMPARISON PROGRAM TEXT B3.12.l 1

10/04/2007

Title:

LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL TEXT B3.12.2 1

12/03/2010

Title:

LOADS CONTROL PROGRAM BASES HEAVY LOADS REQUIREMENTS TEXT B3.12.3 0

11/19/2002

Title:

LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS Page 15 of 15 Report Date: 08/02/21

Rev. 15 3.7.3 Fire Protection Fire Detection Instrumentation 3.7.3.8 3.7.3.8 Fire Detection Instrumentation TRO 3.7.3.8 The fire detection instrumentation for each fire detection zone shown in Table 3.7.3.8-1 shall be OPERABLE.

APPLICABILITY:

Whenever equipment protected by the fire detection instrument is required to be OPERABLE.

ACTIONS


NOTE-----------------

Separate condition entry is allowed for each instrument.

CONDITION REQUIRED ACTION COMPLETION TIME A. The number of A.1 Establish an hourly fire watch 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> OPERABLE fire detection patrol instruments less than the Minimum Instruments AND Operable requirement of Table 3.7.3.8-1 A.2.1 Inspect the accessible Once per hour zone(s) with inoperable

  • instrument(s)

OR A.2.2 Inspect the affected area Once per hour surrounding any inaccessible zones B. Communication between B.1 Establish an hourly fire watch 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> Control Room and a for Local Control Panel Local Control Panel with Monitoring local monitoring capability is not operable.

AND B.2 Monitor status for the Once per hour instruments reporting to the Local Control Panel.

SUSQUEHANNA - UNIT 2 TRM / 3.7-26

Rev. 15 Fire Detection Instrumentation 3.7.3.8 TECHNICAL REQUIREMENT SURVEILLANCE


NOTE-----------------

When a detector is placed in an inoperable status solely for performance of required Surveillances, entry into associated Conditions and required Actions may be delayed for up to 15 minutes to allow for the individual detector trip to clear.

SURVEILLANCE FREQUENCY TRS 3.7.3.8.1 Perform CHANNEL FUNCTIONAL TEST on 12 months accessible fire detection instruments.

TRS 3.7.3.8.2 Verify that the supervised circuits supervision 12 months associated with the detector alarms of each of the fire detection instruments listed in Table 3.7.3.8-1 are OPERABLE.

TRS 3.7.3.8.3 Perform CHANNEL FUNCTIONAL TEST on Prior to startup inaccessible fire detection instruments.

from each COLD SHUTDOWN exceeding 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> unless performed in the previous 12 months TRS 3.7.3.8.4 Perform CHANNEL FUNCTIONAL TEST on heat 18 months detectors fixed-temperature, non-restorable line type fire detection instrument.

SUSQUEHANNA - UNIT 2 TRM / 3.7-27

Rev. 15 TABLE 3.7.3.8-1 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION FIRE HEAT ZONE ROOM OR AREA ELEV.

TOTAL MIN.

a.

Control Building 0-21A Common Equipment Room Elevator 656'-0" NA NA Lobby 0-22A Above Ceiling/Filler Area 687'-8" NA NA 0-22A Elevator Lobby 676'-0" NA NA Chem Lab OF135 High Temp. Alarm 687'-1 O" 2

1 Chem Lab DS-021 687'-1 O" 2

1 Chem Lab OF138 High Temp. Alarm 687'-1 O" 2

1 Chem Lab DS-022 687'-1 O" 2

1 0-22A Chem Lab OF141 High Temp. Alarm 687'-10" 2

1 Chem Lab DS-023 687'-10" 2

1 Chem Lab OF144 High Temp. Alarm 687'-1 O" 2

1 Chem Lab DS-024 687'-1 O" 2

1 Egress Corridor to South Stairwell 686'-6" NA NA 0-23 C-134 Storage (HCVS ROS Area) 686'-6" NA NA 0-24A UPS Panel Room U-2 698'-0" 4

2 0-24B Corridor 698'-0" NA NA 0-24B Corridor Elevator Lobby 698'-0" NA NA 0-240 U1 Lower Relay Room 698'-0" 4

2 0-24E Computer Room 698'-0" NA NA 0-24E Computer Room (Above Ceiling) 698'-0" 12 6

Computer Room 1U720 697'-0" NA NA PGCC Underfloor 1U722 697'-0" NA NA 0-24E 1U724 697'-0" NA NA 1U726 697'-0" NA NA 2U721 697'-0" NA NA 2U723 697'-0" NA NA 2U725 697'-0" NA NA 2U727 697'-0" NA NA 0-24F Computer Maintenance Rm and Office 698'-0" NA NA 0-24G U2 Lower Relay Room 698'-0" 4

2 U-2 Lower Relay Room 2U704 697'-0" 11 6

PGCC Halon Panel 2U705 697'-0" 11 6

0-24G Division II 2U706 697'-0" 11 6

2U731 697'-0" 10 5

2U732 697'-0" 11 6

SUSQUEHANNA - UNIT 2 TRM / 3.7-28 Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE SMOKE TOTAL MIN.

1 1

10 5

1 1

NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 1

1 1

1 2

1 3

2 1

1 4

2 6

3 4

2 4

2 4

2 4

2 4

2 4

2 4

2 4

2 4

2 2

1 4

2 6

3 6

3 6

3 6

3 6

3

Rev. 15 TABLE 3.7.3.8-1 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION FIRE HEAT ZONE ROOM OR AREA ELEV.

TOTAL MIN.

0-24J South Cable Chase 698'-0" 1

1 0-24L Center Cable Chase 698'-0" 1

1 0-24M North Cable Chase 698'-0" 1

1 0-25A U-2 Lower Cable Spreading Room 714'-0" 20 10 0-25B South Cable Chase 714'-0" 1

1 0-25C Center Cable Chase 714'-0" 1

1 0-250 North Cable Chase 714'-0" 1

1 0-25E U-1 Lower Cable Spreading Room 714'-0" 26 13 0-25E U-1 Lower Cable Spreading Room 714'-0" NA NA Elevator Lobby 0-26A Copy Room 729'-1" NA NA 0-26B South Cable Chase 729'-1" NA NA 0-26C Center Cable Chase 729'-1" NA NA 0-260 North Cable Chase 729'-1" NA NA 0-26E Locker Room 729'-1" NA NA 0-26F Vestibule Elevator Lobby 729'-1" NA NA 0-26F Vestibule (Under Floor) 728'-1" NA NA 0-26G Shift Office 729'-1" NA NA 0-26G Shift Office (Under Floor) 728'-1" NA NA 0-26H Control Room (Under Floor Unit 1) 728'-1" NA NA 0-26H Control Room (Under Floor Unit 2) 728'-1" NA NA 0-26H Control Room 729'-1" NA NA 0-26H Control Room (Above Ceiling) 729'-1" NA NA 0-261 Operational Support Center 729'-1" NA NA 0-261 Operational Support Center 728'-1" NA NA (Under Floor) 0-26J Vestibule 729'-1" NA NA 0-26J Vestibule (Under Floor) 728'-1" NA NA 0-26K Technical Support Center 741'-1" NA NA 0-26K Technical Support Center Elevator Lobby 741'-1" NA NA 0-26K Technical Support Center 741'-1" NA NA (Above Ceiling) 0-26L Conference Room 741 '-1" NA NA 0-26L Conference Room (Above Ceiling) 741'-1" NA NA 0~26M U-1 TSC Soffit 729'-1" NA NA 0-26M U-1 TSC Soffit 741'-1" NA NA 0-26N U-1 Control Room Soffit 741'-1" NA NA 0-26P U-2 Control Room Soffit 741'-1" NA NA 0-26R U-2 TSC Soffit 729'-1" NA NA 0-26R U-2 TSC Soffit 741'-1" NA NA SUSQUEHANNA - UNIT 2 TRM / 3.7-29 Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE SMOKE TOTAL MIN.

NA NA NA NA NA NA 6

3 NA NA NA NA NA NA 5

3 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 2

1 15 8

12 6

10 5

9 5

1 1

2 1

1 1

1 1

10 5

1 1

5 3

6 3

2 1

2 1

2 1

2 1

2 1

2 1

2 1

Rev. 15 TABLE 3. 7.3.8-1 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION FIRE HEAT ZONE ROOM OR AREA ELEV.

TOTAL MIN.

0-26S South Cable Chase 741'-1" 1

1 0-26T Center Cable Chase 741'-1" 1

1 0-26V North Cable Chase 741 '-1" 1

1 0-27A U-2 Upper Relay Room 754'-0" 4

2 U-2 Upper Relay Room 2U700 753'-0" 11 6

PGCC Halon Panel 2U701 753'-0" 11 6

0-27A Division I 2U702 753'-0" 11 6

2U703 753'-0" 11 6

2U730 753'-0" 11 6

0-278 U-2 Upper Cable Spreading Room 753'-0" 24 12 0-27C U-1 Upper Cable Spreading Room 753'-0" 23 12 0-27C U-1 Upper Cable Spreading Room 754'-0" NA NA Elevator Lobby 0-270 Electrician's Office 754'-0" 2

1 0-27E U-1 Upper Relay Room 754'-0" 4

2 0-27F South Cable Chase 754'-0" 1

1 0-27G Center Cable Chase 754'-0" 1

1 0-27H North Cable Chase 754'-0" 1

1 0-28A-I Equipment Room 771 '-0" NA NA 0-28A-11 Equipment Room 771'-0" NA NA 0-288-1 Equipment Room 771'-0" NA NA 0-288-11 Equipment Room 771 '-0" NA NA 0-288-11 Equipment Room Elevator Lobby 771'-0" NA NA 0-28C Battery Room 771'-0" NA NA 0-280 Battery Room 771'-0" NA NA 0-28E Battery Room 771'-0" NA NA 0-28F Battery Room 771'-0" NA NA 0-28G Battery Room 771 '-0" NA NA 0-28H Repair Shop 771 '-0" NA NA 0-281 Battery Room 771'-0" NA NA 0-28J Battery Room 771'-0" NA NA 0-28K Battery Room 771'-0" NA NA 0-28L Battery Room 771'-0" NA NA 0-28M Battery Room 771'-0" NA NA SUSQUEHANNA - UNIT 2 TRM / 3.7-30 Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE SMOKE TOTAL MIN.

NA NA NA NA NA NA 3

2 6

3 6

3 6

3 6

3 6

3 5

3 7

4 1

1 1

1 2

1 NA NA NA NA NA NA 1

1 3

2 1

1 2

1 1

1 1

1 1

1 1

1 1

1 1

1 2

1 1

1 1

1 1

1 1

1 1

1

Rev. 15 TABLE 3.7.3.8-1 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION FIRE HEAT ZONE ROOM OR AREA ELEV.

TOTAL MIN.

0-28N Battery Room 771 '-0" NA NA 0-28P South Cable Chase 771'-0" 1

1 0-28Q Center Cable Chase 771 '-0" 1

1 0-28R North Cable Chase 771'-0" 1

1 0-28T Battery Room 771'-0" NA NA 0-29A Elevator Vestibule 783'-0" NA NA 0-29B H&V Equipment Room 783'-0" NA NA 0-30A HVAC Equipment Room 806'-0" NA NA 0-30A Freight Elevator Lobby 806'-0" NA NA 0-30A CREOASS 0F125A High Temp. Alarm 806'-0" 7

4 0-30A CREOASS DS-091 806'-0" 7

4 0-30A CREOASS 0F125B High Temp. Alarm 806'-0" 7

4 0-30A CREOASS DS-092 806'-0" 7

4 0-30A SGTS - 0F169A High Temp. Alarm 806'-0" 1

1 0-30A SGTS - DS-093 806'-0" 1

1 0-30A SGTS - 0F169B High Temp. Alarm 806'-0" 1

1 0-30A SGTS - DS-094 806'-0" 1

1

b.

Reactor Building 2-1A Core Spray Pump Room 645'-0" NA NA 2-18 Core Spray Pump Room 645'-0" NA NA 2-1B Elevator Lobby 645'-0" NA NA 2-1C HPCI Pump Room 645'-0" 2

1 2-10 RCIC Pump Room 645'-0" 2

1 2-1E RHR Pump Room 645'-0" NA NA 2-1F RHR Pump Room 645'-0" NA NA 2-1G Sump Room 645'-0" NA NA 2-11 Stairwell 202 645'-818' NA NA 2-2A Access Area and Remote Shutdown 670'-0" NA NA Panel Room 2-2A Elevator Lobby 670'-0" NA NA 2-2B Core Spray Pump Room 670'-0" NA NA 2-3A Access Area 683'-0" NA NA 2-3A Access Area Elevator Lobby 683'-0" NA NA 2-3B-N Equipment Removal Area - North 683'-0" NA NA 2-3B-S Equipment Removal Area - South 683'-0" NA NA 2-3B-W Equipment Removal Area - Wraparound 683'-0" NA NA 2-3C-N Equipment Access Area - North 683'-0" NA NA SUSQUEHANNA-UNIT 2 TRM / 3.7-31 Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE SMOKE TOTAL MIN.

1 1

NA NA NA NA NA NA 1

1 1

1 10 5

19 10 1

1 NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 8

4 6

3 1

1 7

4 5

3 13 7

15 8

2 1

2 1

5 3

1 1

11 6

4 2

1 1

13 7

1 1

2 1

4 2

Rev. 15 TABLE 3.7.3.8-1 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION FIRE HEAT ZONE ROOM OR AREA ELEV.

TOTAL MIN.

2-3C-S Equipment Access Area - South 683'-0" NA NA 2-3C-W Equipment Access Area - Wraparound 683'-0" NA NA 2-4A-N Containment Access Area - North 719'-0" NA NA 2-4A-S Containment Access Area - South 719'-0" NA NA 2-4A-S Containment Access Area Elevator 719'-0" NA NA Lobby 2-4A-W Containm*ent Access Area - Wraparound 719'-0" NA NA 2-48 Pipe Penetration Room 719'-1" NA NA 2-4C Switchgear Room 719'-1" NA NA 2-40 Switchgear Room 719'-1" NA NA 2-4G Main Steam Pipeway 719'-1" 4*

2 2-4G Exhaust Fan Room (Note: these 799'-1" 2

1 detectors also cover el. 749'-1")

2-5A-N Standby Control Systems Area 749'-0" NA NA 2-5A-S General Access Area - South 749'-0" NA NA 2-5A-S General Access Area Elevator Lobby 749'-0" NA NA 2-5A-W Access Corridor - Wraparound 749'-0" NA NA 2-58 Valve Access Area 761 '-10" 4

2 2-5C.

RWCU Backwash Tank 749'-1" NA NA 2-5D RWCU Pumps & Heat Exchangers 749'-1" NA NA 2-5E Penetration Room 749'-1" NA NA 2-5F Load Center Room 749'-1" NA NA 2-5G Load Center Room 749'-1" NA NA 2-5H Instrument Repair Room 749'-1" NA NA 2-6A Access Area 779'-1" NA NA 2-68 Load Center Room 779'-1" NA NA 2-6C Electrical Equipment Room 779'-1" NA NA 2-60 H&V Equipment Room 779'-1" NA NA 2-6E Hatch and Laydown Area 779'-1" NA NA 2-7A H&V Fan & Filter Rooms 799'-1" NA NA 2-7A HVAC Filter 2F257A High Temp. Alarm 799'-0" 7

4

  • Inaccessible SUSQUEHANNA - UNIT 2 TRM / 3.7-32 Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE SMOKE TOTAL MIN.

4 2

5 3

IONIZATION PHOTO ELECTRIC TOTAL MIN.

TOTAL MIN.

11 6

3 2

SMOKE TOTAL MIN.

10 5

1 1

5 3

1 1

2 1

2 1

NA NA NA NA IONIZATION PHOTO ELECTRIC TOTAL MIN.

TOTAL MIN.

17 9

7 4

5 3

2 1

1 1

NA NA 2

1 2

1 SMOKE TOTAL MIN.

NA NA 1

1 8

4 2

1 2

1 2

1 2

1 11 6

4 2

2 1

12 6

2 1

14 7

NA NA

Rev. 15 TABLE 3.7.3.8-1 Fire Detection Instrumentation 3.7.3.8 FIRE DETECTION INSTRUMENTATION INSTRUMENT LOCATION INSTRUMENT OPERABLE FIRE HEAT SMOKE ZONE ROOM OR AREA ELEV.

TOTAL MIN.

TOTAL MIN.

2-7A HVAC Filter 2F257A DS-281 799'-0" 7

4 NA NA 2-7A HVAC Filter 2F257B High Temp. Alarm 799'-0" 7

4 NA NA 2-7A HVAC Filter 2F257B DS-282 799'-0" 7

4 NA NA 2-7A HVAC Filter 2F217A High Temp. Alarm 799'-0" 5

3 NA NA 2-7A HVAC Filter 2F217A DS-283 799'-0" 5

3 NA NA 2-7A HVAC Filter 2F217B High Temp. Alarm 799'-0" 5

3 NA NA SUSQUEHANNA - UNIT 2 TRM / 3.7-32a

Rev. 15 INSTRUMENT LOCATION FIRE ZONE ROOM OR AREA 2-7A HVAC Filter 2F217B DS-284 0-6G Surge Tank Vault 0-8A Refueling Floor 0-8A Refueling Floor Elevators C.

ESW Pumphouse 0-51 Pump Room 0-52 Pump Room C.

ESW Pumphouse 0-51 Pump Room 0-52 Pump Room

d.

Diesel Generator Building 0-41A Diesel Generator "A" Bay 0-41B Diesel Generator "B" Bay 0-41C Diesel Generator "C" Bay 0-41D Diesel Generator "D" Bay

e.

Diesel Generator E Building 0-41E Diesel Generator Rooms

f.

Outside Area 0-00 Startup Transformer (OX103) 0-00 Startup Transformer (OX 104) 0-00 ESS Transformer-DS-016 OX201 ox 213 0-00 ESS Transformer - DS-017 OX203 OX211 SUSQUEHANNA - UNIT 2 TABLE 3.7.3.8-1 FIRE DETECTION INSTRUMENTATION Fire Detection Instrumentation 3.7.3.8 INSTRUMENT OPERABLE HEAT SMOKE ELEV.

TOTAL MIN.

TOTAL MIN.

799'-0" 5

3 NA NA 779'-4" NA NA 2

1 818'-1" NA NA 60 30 818'-1" NA NA 2

1 685'-6" NA NA 6

3 685'-6" NA NA 6

3 685'-6" NA NA 6

3 685'-6" NA NA 6

3 HEAT INFRA-RED SMOKE 660'-0" &

22 11 2

1 15 9

677'-0" 710'-9" N/A N/A NIA N/A 8

4 660'-0" &

23 12 2

1 15 8

677'-0" 710'-9" N/A N/A N/A N/A 9

5 660'-0" &

22 11 2

1 15 8

677'-0" 710'-9" N/A N/A N/A N/A 8

4 660'-0" &

22 11 2

1 15 8

677'-0" 710'9" N/A N/A N/A N/A 8

4 HEAT INFRA-RED SMOKE 656'-6" &

1 1

NA NA 21 11 675'-6" &

NA NA 6

3 3

2 708'-0" NA NA 4

2 NA NA HEAT SMOKE DS-014 NA 10 5

NA NA DS-015 NA 12 6

NA NA NA 6

3 NA NA NA 6

3 NA NA NA 6

3 NA NA NA 6

3 NA NA TRM / 3.7-33

Rev. 4 Primary Containment Penetration Conductor Overcurrent Protective Devices 3.8.1 3.8 Electrical Power 3.8.1 Primary Containment Penetration Conductor Overcurrent Protective Devices TRO 3.8.1 The primary containment penetration conductor overcurrent protective devices in Table 3.8.1-1 shall be OPERABLE.

Applicability: MODES 1, 2 and 3 ACTIONS


NOTE----------------

Separate condition entry is allowed for each device.

CONDITION REQUIRED ACTION COMPLETION TIME A.

One or more A.1 Deenergize the circuit(s) and 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> containment penetration declare the affected system or conductor overcurrent component inoperable.

protective devices inoperable.

AND A.2 Verify affected circuit Once per 7 days deenerg ized.

B.

Required Action and B.1 Be in MODE 3.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> associated Completion Time for Condition A not AND met.*

B.2 Be in MODE4.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> SUSQUEHANNA - UNIT 2 TRM / 3.8-1

Rev. 4 Primary Containment Penetration Conductor Overcurrent Protective Devices 3.8.1 TECHNICAL REQUIREMENT SURVEILLANCE TRS 3.8.1.1 TRS 3.8.1.2 TRS 3.8.1.3 SURVEILLANCE


NO TE---------------------------

F or each circuit breaker found inoperable, an additional representative sample of ;::,:10% of all the circuit breakers of the inoperable type shall be functionally tested until no more failures are found or all circuit breakers of that type have been functionally tested.

Perform a functional test on a representative sample of

,
10% of each type of lower voltage circuit breaker.

Perform a functional test on each overcurrent relay.


NOTE---------------------

The provisions of TRS 3.0.2 are not applicable Subject each circuit breaker to inspection and preventive maintenance.

SUSQUEHANNA - UNIT 2 TRM / 3.8-2 FREQUENCY 24 months 24 months 120 months

Primary Containment Penetration Conductor Overcurrent Protective Devices Rev.4 3.8.1 TABLE 3.8.1-1 (Page 1 of 2)

PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES Circuit Breaker Designation System/Equipment Powered A.

Type 150A Frame - Thermal Magnetic

1.

28237043 28237043A Rx Recirc/HV-B31-2F023A

2.

28219022 28219022A Rx Recirc/HV-B31-2F031A

3.

28219023 28219023A Rx Recirc/HV-B31-2F032A

4.

28246011 28246011A Rx Recirc/HV-B31-2F023B

5.

28229022 28229022A Rx Recirc/HV-B31-2F031B

6.

28229023 28229023A Rx Recirc/HV-B31-2F032B

7.

28236042 28236042A Drywell Air Flow/2V411A

8.

28236032 28236032A Drywell Air Flow/2V412A

9.

28236011 28236011A Drywell Air Flow/2V413A

10.

28236033 28236033A Drywell Air Flow/2V414A

11.

28236053 28236053A RWCU/HV-G33-2F001 12.

28236082 28236082A Drywell Air Flow/2V415A

13.

28236043 28236043A Drywell Air Flow/2V416A

14.

28236021 28236021A Drywell Air Flow/2V417A

15.

28246091 28246091A Drywell Air Flow/2V411 B

16.

28246103 28246103A Drywell Air Flow/2V412B

17.

28246102 28246102A Drywell Air Flow/2V413B

18.

28246061 28246061A Drywell Air Flow/2V414B

, 19.

28246072 28246072A Drywell Air Flow/2V415B

20.

28246081 28246081A Drywell Air Flow/2V416B

21.

28246051 28246051A Drywell Air Flow/2V417B

22.

28236123 28236123A Drywell Air Flow/2V418A

23.

28246121 28246121A Drywell Air Flow/2V418B

24.

28236052 28236052A RHR/HV-E11-2F009

25.

28237073 28237073A RHR/H\\/-E11-2F022

26.

28237082 28237082A HPCI/HV-E41-2F002

27.

28253021 28253021A NSSS/HV-B21-2F011A

28.

28263023 28263023A NSSS/HV-B21-2F011 B

29.

28253041 28253041A MSIV Hoist/TBB25 30.

28263021 28263021A MSIV Hoist/TBB26 SUSQUEHANNA - UNIT 2 TRM / 3.8-3

Primary Containment Penetration Conductor Overcurrent Protective Devices Rev.4 3.8.1 TABLE 3.8.1-1 (Page 2 of 2)

PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES Circuit Breaker Designation System/Equipment Powered B.

Type 150A Frame - Magnetic

1.

28236023 28236023A Cont. Inst. Gas/HV-22603

2.

28246022 28246022A RCIC/HV-E51-2F007

3.

28237072 28237072A NSSS/HV-821-2F016

4.

28236102 28236102A NSSS/HV-821-2F00 1

5.

28246112 28246112A NSSS/HV-821-2F002

6.

28246113 28246113A NSSS/HV-821-2F005

7.

28253052 28253052A RWCU/HV-G33-2F102

8.

28263043 28253043A RWCU/HV-G33-2F100

9.

28263052 28263052A RWCU/HV-G33-2F106

10.

28246062 28246062A RBCCW/HV-21346

11.

28246012 28246012A RBCCW/HV-21345

12.

28253063 28253063A Drywell Sump/2P402A

13.

28263071 28263071A Drywell Sump/2P4028

14.

28253043 28253043A Drywell Sump/2P403A

15.

28263072 28263072A Drywell Sump/2P4038 C.

Circuit BreakersTripped by Overcurrent Relays

1.

2A20501 2A20502 Rx Recirc/2P401A

2.

2A20601 2A20602 Rx Recirc/2P401 B SUSQUEHANNA - UNIT 2 TRM / 3.8-4