ML20054K849: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 15: Line 15:
| document type = TECHNICAL SPECIFICATIONS, TECHNICAL SPECIFICATIONS & TEST REPORTS
| document type = TECHNICAL SPECIFICATIONS, TECHNICAL SPECIFICATIONS & TEST REPORTS
| page count = 1
| page count = 1
| project = TAC:53271, TAC:53272
| stage = Other
}}
}}



Latest revision as of 05:40, 14 November 2023

Proposed Tech Spec Changes Re Periodic Testing of Auxiliary Feedwater Sys Automatic Actuation Logic
ML20054K849
Person / Time
Site: Point Beach  NextEra Energy icon.png
Issue date: 06/30/1982
From:
WISCONSIN ELECTRIC POWER CO.
To:
Shared Package
ML20054K848 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.E.1.1, TASK-2.E.1.2, TASK-TM TAC-53271, TAC-53272, NUDOCS 8207060215
Download: ML20054K849 (1)


Text

.. .. . .

e TABLE 15.4.1-1 (CONTINUED) *

, )

e, Channel '

Description Check Calibrate Test Remarks  ;

10. Rod Position Bank Counters S (1) *
  • N.A. N.A. 1) With analog rod position
11. Steam Generator Level S ** R M (1) *
12. Steam Generator Flow Mismatch S ** R M**
13. Charging Flow N.A. R N.A.
14. Residual Heat Removal Pump Flow N.A. R N.A.
15. Boric Acid Tank Level D R N.A.

I'

16. Refueling Water Storage Tank Level N.A. R N.A.
17. Volume Control Tank Level N.A. R N.A.
18. Reactor Containment Pressure D R B/W (1) ** 1) Isolation valve signal 15/21 '
19. Radiation Monitoring System D R M
20. Boric Acid Control N.A. R N.A. .

l21. Containment Sump Level N.A. R N.A.

l22. Turbine Overspeed Trip

  • N.A. R M (1) *
  • 1) Block trip 15/21

'23. Accumulator Level and Pressure S R N.A.

I

  • Overspeed Trip Mechanism, and Independent Turbine Speed Detection and Valve Trip System.

)* Not required during periods of refueling shutdown, but must be performed prior to starting up if it has not been performed during the previous surveillance period.

8207060215 820630 PDR ADOCK 05000266 P PDR '