ML20203B533: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
Line 17: Line 17:


=Text=
=Text=
{{#Wiki_filter:}}
{{#Wiki_filter:l ,
February 17, 1998 Mr. C. M. Vaughan, Acting Manager
    ' Facility Licensing General Elcctric Company P.O. Box 780, MC J26 Wilmington, North Carolina 28402 4
 
==SUBJECT:==
REVISION TO FUNDAMENTAL NUCLEAR MATERIAL CONTROL PLAN (TAC NO. L31038)
 
==Dear Mr. Vaughan:==
 
This is in response to your correspondence dated November 13,1997, by which you submitted -
changes to Chapters 3.0,4.0, and 7.0 of your Fundamental Nuclear Material Control (FNMC)
Plan. We have completed our review of the submitted changes and have determined that these changes do not decrease the effectiveness of the FNMC Plan, and thus, that they were properly submitted under the provisions of 10 CFR 70.32(c). Accordingly, the revisien to your FNMC Plan is acceptable, and Safeguards License Condition SG-1.1 of your Materials License SNM-1097 will be updated in a future license amendment to reflect the current changes.
Enclosed is a copy of the Safeguards Evaluation Report, which summarizes the review.
We concur with your determination that the enclosures to the November 13,1997, letter contain Information of the type specified in 10 CFR 2.790(d) which is deemed to be commercial or financici within the meaning of 10 CFR 9.17(a)(4). Accordingly, said enclosures will be withheld from public dmelosure unless subject to the provisions of 10 CFR 9.23.
Sincerely, Griginal signed by:
Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS                                j Docket 70-1113                                                                                    f License SNM-1097                                                                          [3 [) h [ ,
Enc losure: Safeguards Evaluation Report 4
DISTRIBUTION: w/ encl. (Control No. 2EOS) [ COMPLETED)
    - Docket 70-1113        PUBLIC                NRC File Center              SHO FCLB R/F              FCSS R/F              NMSS R/F                      AGooden, Ril WSchwink, FCOB        PMDA                  BHorn, FRIB                  Madams 4
OFC      FCLB        E    FCLB      %    FCLB          C    FCLB,          FCLB      h M'CNil$ay NAME      TPham h          PShea    (h    CHrabalC AG                        MWeberk DATE      1/.f.[/98        1/ M 8        [1 5 /98          # f /98        74 /h98 C = COVER                    E = COVER & ENCLOSURE                N = NO COPY OFFICIAL RECORD COPY
                                . - ni                                F?P 1000ET'  L CM DpSyE*!D G        id &M Nft9y 9002240314 980217 PDR    ADOCK 07001113
 
occ oq p+
ht                                UNITED STATE 2 g                j            NUCLEAR REGULATORY COMMISSION W ASHINGToN, D.C. 200MH1001 g
        %, * . . . . /'$                                February 17, 1998 Mr. C. M. Vaughan, Acting Manager Facility Licensing General Electric Company P.O. Box 780, MC J26 Wilmin2 ton, North Carolina 28402
 
==SUBJECT:==
REVISION TO FUNDAMENTAL NUCLEAR MATERIAL CONTROL PLAN (TAC NO L31038)
 
==Dear Mr. Vaughan:==
 
This is in response to your correspondence dated November 13,1997, by which you submitted changes to Chapters 3.0,4.0, and 7.0 of your Fundamental Nuclear Material Control (FNMC)
Plan. We have completed our review of the submitted changes and have determined that these changes do not decrease the effectiveness of the FNMC Plan, and thus, that they were properly submitted under the provisions of 10 CFR 70.32(c). Accordingly, the revision to your FNMC Plan is acceptable, and Safeguards License Condition SG-1.1 of your Materials License SNM-1097 will be updated in a future license amendment to reflect the current changes.            t Enclosed is a copy of the Safeguards Evaluation Report, which summarizes the review.
We concur with your determination that the enclosures to the November 13,1997, letter contain information of the type specified in 10 CFR 2.790(d) which is deemed to be commercial or financial within the meaning of 10 CFR 9.17(a)(4). Accordingly, said enclosures will be withheld from public disclosure unless subject to the provisions of 10 CFR 9.23.
Sincerely, 7"/W          W Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1113 License SNM-1097
 
==Enclosure:==
Safegua:ds Evaluation Report}}

Revision as of 03:43, 1 January 2021

Informs That Revs to Chapters 3.0,4.0 & 7.0 of Fundamental Nuclear Matl Control Plan Are Acceptable & Safeguards License Condition SG-1.1 of License SNM-1097 Will Updated in Future License Amend.Ser Summarizing NRC Review,Encl
ML20203B533
Person / Time
Site: 07001113
Issue date: 02/17/1998
From: Weber M
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Vaughan C
GENERAL ELECTRIC CO.
Shared Package
ML20203B538 List:
References
TAC-L31038, NUDOCS 9802240314
Download: ML20203B533 (2)


Text

l ,

February 17, 1998 Mr. C. M. Vaughan, Acting Manager

' Facility Licensing General Elcctric Company P.O. Box 780, MC J26 Wilmington, North Carolina 28402 4

SUBJECT:

REVISION TO FUNDAMENTAL NUCLEAR MATERIAL CONTROL PLAN (TAC NO. L31038)

Dear Mr. Vaughan:

This is in response to your correspondence dated November 13,1997, by which you submitted -

changes to Chapters 3.0,4.0, and 7.0 of your Fundamental Nuclear Material Control (FNMC)

Plan. We have completed our review of the submitted changes and have determined that these changes do not decrease the effectiveness of the FNMC Plan, and thus, that they were properly submitted under the provisions of 10 CFR 70.32(c). Accordingly, the revisien to your FNMC Plan is acceptable, and Safeguards License Condition SG-1.1 of your Materials License SNM-1097 will be updated in a future license amendment to reflect the current changes.

Enclosed is a copy of the Safeguards Evaluation Report, which summarizes the review.

We concur with your determination that the enclosures to the November 13,1997, letter contain Information of the type specified in 10 CFR 2.790(d) which is deemed to be commercial or financici within the meaning of 10 CFR 9.17(a)(4). Accordingly, said enclosures will be withheld from public dmelosure unless subject to the provisions of 10 CFR 9.23.

Sincerely, Griginal signed by:

Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS j Docket 70-1113 f License SNM-1097 [3 [) h [ ,

Enc losure: Safeguards Evaluation Report 4

DISTRIBUTION: w/ encl. (Control No. 2EOS) [ COMPLETED)

- Docket 70-1113 PUBLIC NRC File Center SHO FCLB R/F FCSS R/F NMSS R/F AGooden, Ril WSchwink, FCOB PMDA BHorn, FRIB Madams 4

OFC FCLB E FCLB  % FCLB C FCLB, FCLB h M'CNil$ay NAME TPham h PShea (h CHrabalC AG MWeberk DATE 1/.f.[/98 1/ M 8 [1 5 /98 # f /98 74 /h98 C = COVER E = COVER & ENCLOSURE N = NO COPY OFFICIAL RECORD COPY

. - ni F?P 1000ET' L CM DpSyE*!D G id &M Nft9y 9002240314 980217 PDR ADOCK 07001113

occ oq p+

ht UNITED STATE 2 g j NUCLEAR REGULATORY COMMISSION W ASHINGToN, D.C. 200MH1001 g

%, * . . . . /'$ February 17, 1998 Mr. C. M. Vaughan, Acting Manager Facility Licensing General Electric Company P.O. Box 780, MC J26 Wilmin2 ton, North Carolina 28402

SUBJECT:

REVISION TO FUNDAMENTAL NUCLEAR MATERIAL CONTROL PLAN (TAC NO L31038)

Dear Mr. Vaughan:

This is in response to your correspondence dated November 13,1997, by which you submitted changes to Chapters 3.0,4.0, and 7.0 of your Fundamental Nuclear Material Control (FNMC)

Plan. We have completed our review of the submitted changes and have determined that these changes do not decrease the effectiveness of the FNMC Plan, and thus, that they were properly submitted under the provisions of 10 CFR 70.32(c). Accordingly, the revision to your FNMC Plan is acceptable, and Safeguards License Condition SG-1.1 of your Materials License SNM-1097 will be updated in a future license amendment to reflect the current changes. t Enclosed is a copy of the Safeguards Evaluation Report, which summarizes the review.

We concur with your determination that the enclosures to the November 13,1997, letter contain information of the type specified in 10 CFR 2.790(d) which is deemed to be commercial or financial within the meaning of 10 CFR 9.17(a)(4). Accordingly, said enclosures will be withheld from public disclosure unless subject to the provisions of 10 CFR 9.23.

Sincerely, 7"/W W Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1113 License SNM-1097

Enclosure:

Safegua:ds Evaluation Report