|
|
(One intermediate revision by the same user not shown) |
Line 2: |
Line 2: |
| | number = ML20247M695 | | | number = ML20247M695 |
| | issue date = 05/20/1998 | | | issue date = 05/20/1998 |
| | title = Forwards RAI Re GL 96-06, Assurance of Equipment Operability & Containment Integrity During Design-Basis Accident Conditions, Dtd 960930 for Plant,Unit 2 | | | title = Forwards RAI Re GL 96-06, Assurance of Equipment Operability & Containment Integrity During Design-Basis Accident Conditions, for Plant,Unit 2 |
| | author name = Harold J | | | author name = Harold J |
| | author affiliation = NRC (Affiliation Not Assigned) | | | author affiliation = NRC (Affiliation Not Assigned) |
Line 11: |
Line 11: |
| | contact person = | | | contact person = |
| | document report number = GL-96-06, GL-96-6, TAC-M96822, NUDOCS 9805260340 | | | document report number = GL-96-06, GL-96-6, TAC-M96822, NUDOCS 9805260340 |
| | | title reference date = 09-30-1996 |
| | document type = CORRESPONDENCE-LETTERS, OUTGOING CORRESPONDENCE | | | document type = CORRESPONDENCE-LETTERS, OUTGOING CORRESPONDENCE |
| | page count = 6 | | | page count = 6 |
| | | project = TAC:M96822 |
| | | stage = RAI |
| }} | | }} |
|
| |
|
Line 26: |
Line 29: |
| request for licensees to evaluate cooling water systems that serve containment air coolers to I assure that they are not vulnerable to waterhammer and two-phase flow conditions. l l | | request for licensees to evaluate cooling water systems that serve containment air coolers to I assure that they are not vulnerable to waterhammer and two-phase flow conditions. l l |
| Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and l l | | Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and l l |
| two-phase flow issues for Indian Point Unit 2 in a letter dated January 28,1997, in order to i | | two-phase flow issues for Indian Point Unit 2 in a {{letter dated|date=January 28, 1997|text=letter dated January 28,1997}}, in order to i |
| complete our review of your resolution of these issues, we will require additional information as i discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at l l | | complete our review of your resolution of these issues, we will require additional information as i discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at l l |
| 301-415-1421. | | 301-415-1421. |
Line 55: |
Line 58: |
| ) | | ) |
| Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment Integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions. | | Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment Integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions. |
| Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for Indian Point Unit 2 in a letter dated January 28,1997. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421. | | Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for Indian Point Unit 2 in a {{letter dated|date=January 28, 1997|text=letter dated January 28,1997}}. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421. |
| Sincerely, Original Signed by: | | Sincerely, Original Signed by: |
| Jefferey F. Harold, Project Manager Project Directorate 1-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket No. 50-247 | | Jefferey F. Harold, Project Manager Project Directorate 1-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket No. 50-247 |
Line 80: |
Line 83: |
|
| |
|
| Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions. | | Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions. |
| Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for indian Point Unit 2 in a letter dated January 28,1997. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421. | | Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for indian Point Unit 2 in a {{letter dated|date=January 28, 1997|text=letter dated January 28,1997}}. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421. |
| Sincerely, | | Sincerely, |
| / | | / |
Letter Sequence RAI |
---|
|
|
MONTHYEARML20247M6951998-05-20020 May 1998 Forwards RAI Re GL 96-06, Assurance of Equipment Operability & Containment Integrity During Design-Basis Accident Conditions, for Plant,Unit 2 Project stage: RAI 1998-05-20
[Table View] |
|
---|
Category:CORRESPONDENCE-LETTERS
MONTHYEARML20217B3331999-10-0707 October 1999 Responds to 990825 Telephone Call Re Presense of Polychlorinated Biphenyl Wastes at Plant,Unit 1 ML20212F4481999-09-17017 September 1999 Forwards NRC Form 536 Containing Currently Proposed Site Specific Operator Licensing Exam Schedule & Estimates of Number of Applicants for Generic Fundamentals Exams Through Cy 2003 ML20212F7051999-09-14014 September 1999 Forwards Rev 19 to Ipn,Units 1 & 2 Physical Security Plan. Plan Withheld,Per 10CFR2.790(d) & 73.21 ML20211N0681999-09-0202 September 1999 Informs That Commission Requested Publication of Notice of Consideration of Issuance of Amend to Fol,Proposed NSHC Determination & Opportunity for Hearing. Amend Changes Senior Reactor License Requirement for Operations Manager ML20211H6291999-08-26026 August 1999 Forwards NPDES Discharge Monitoring Rept for July 1999 for Indian Point,Units 1,2 & 3. Rept of Noncompliance Is Attached for Noncompliance Which Occurred at Unit 3 ML20211E1531999-08-18018 August 1999 Forwards Semi Annual fitness-for-duty Program Performance Data for 990101-990630,IAW 10CFR26.71(d) ML20211H6051999-08-18018 August 1999 Forwards Rev 8 to Security Force Training & Qualification Plan, for Indian Point 3 Nuclear Power Plant.Rev Facilitates Transition of Duty Weapons Carried by Security Force Members from Revolvers to Semiautomatic Pistols ML20211A9241999-08-11011 August 1999 Informs That IPS Currently Estimates,That Approx Two Licensing Actions Will Be Submitted to NRC During Remainder of 1999 NRC Fiscal Yr & Approx Ten Will Be Submitted During 2000 NRC Fiscal Yr ML20210M7251999-07-26026 July 1999 Forwards Projection of Ability to Pay Retrospective Premium Adjustment for Period of Aug 1999 to 000731, Which Demonstrates That Ceny Will Have Sufficient Cash Flow &/Or Cash Reserve Available Throughout Period to Pay Premium ML20210G8911999-07-20020 July 1999 Forwards Application for Amend to License DPR-5 for Proposed New TS 3.2.1.i,revising Senior Reactor License Requirement for Operations Manager ML20209B6611999-06-29029 June 1999 Returns Recently Submitted Renewal Applications,Nrc Form 398,for Three Reactor Operators,As They Are Not Completed Properly.List of Docket Numbers & Block Numbers That Contain Incorrect Info & Block Numbers Not Completed.Without Encls ML20196A6371999-06-15015 June 1999 Forwards Rev 19 to Physical Security Plan.Rev Withheld,Per 10CFR2.790(d) & 73.21 ML20207D1861999-05-27027 May 1999 Informs That Effective 990328,NRC Office of NRR Underwent Reorganization.Mt Masnik Section Chief for Indian Point Station,Unit 1.JL Minns Remains Primary Contact for All Routine Licensing & Administrative Matters.Chart Encl ML20205R1981999-04-15015 April 1999 Requests That Dept of Environ Conservation Modify SPDES Permit for IPS IAW Proposed Rev Attached & Described as Listed ML20205R2961999-04-15015 April 1999 Forwards Copy of Proposed Change to Indian Point SPDES Permit NY0004472.Proposed Change Requests Permission to Add Permitted Outfall to Plant as Well as Change Character of Existing Outfall.Without Encl ML20196K8111999-03-31031 March 1999 Forwards Decommissioning Funding Status Rept for Indian Point,Units 1 & 2 Through 981231 ML20205F9711999-03-25025 March 1999 Informs That Under Separate Cover,Licensee Transmitted to Ofc of Nuclear Regulatory Research Annual Rept of Results of Individual Monitoring at Indian Point,Units 1 & 2,for CY98 ML20204F7931999-03-17017 March 1999 Forwards Table Outlining Nuclear Property Insurance Which Has Been Placed on Behalf of Consolidated Edison Co of Ny, Inc.Insurance Covers Indian Point,Units 1 & 2 ML20204J9971999-03-0909 March 1999 Forwards Insp Rept 50-003/98-19 on 981130-990222.No Violations Noted ML20203B9001999-02-0808 February 1999 First Partial Response to FOIA Request for Documents. Forwards Documents Listed in App a Already Available in PDR, Documents in App B Released in Entirety & Documents in App C Being Withheld in Part (Ref Exemption 6) ML20202J6171999-02-0505 February 1999 Forwards Transcript from 990120 Public Meeting Held in Peekskill,Ny Re Decommissioning ML20199H3731999-01-11011 January 1999 Informs That T Schmeiser,Con Ed Plant Manager for Plant Is Retiring,Effective 990111.AA Blind Will Assume Duties & Responsibilities of Plant Manager Until Replacement Named ML20198E9561998-12-21021 December 1998 Forwards Order Prohibiting Involvement in NRC Licensed Activities Re Deliberate Misconduct in Violation of Regulation When False Info Was Provided to Two NRC Licensees ML20198C2371998-12-15015 December 1998 Ltr Contract:Task Order 237, Review & Evaluation of Indian Point 3 Nuclear Power Plant Application for Conversion to Improved TS, Under Contract NRC-03-95-026 ML20198C4911998-12-11011 December 1998 Forwards Rev 18 to Physical Security Plan,Reflecting Organizational Changes & Incorporating Administrative Corrections & Clarifications.Encl Withheld ML20198C3251998-12-11011 December 1998 Responds to ,Responding to NRC Ltr Re Concerns Raised About Potential Chilling Effect from Temp Denial of Site Access to Employee Raising Safety Issues to Util Senior Mgt ML20155H2901998-11-0303 November 1998 Responds to to Lj Callan Expressing Concern About Continued Operation of Indian Point Nuclear Generating Station.Explanation Why NRC Do Not Think Revoking OLs for Indian Point Units 2 & 3 Justified,Provided ML20155F9181998-10-28028 October 1998 Forwards Changes to SPDES Permit,Removing Requirement to Monitor Svc Boiler Blowdown for Phosphates,Eliminate Redundant Sampling of Oil or Grease Entering Flow Tributary to Floor Drains,Per Ts,App B,Section 3.2 ML20155D2791998-10-23023 October 1998 Forwards Corrected Pages for Indian Point Annual Radiological Environ Operating Rept for 1997 ML20154Q1761998-10-21021 October 1998 Second Final Response to FOIA Request for Documents. Documents Listed in App C Being Withheld in Part (Ref FOIA Exemption 7) ML20154L8031998-10-16016 October 1998 Ack Receipt of & Payment in Amount of $55,000 in Electronic Funds for Civil Penalty Proposed by NRC in .Corrective Actions Will Be Examined During Future Insp ML20155H3021998-09-24024 September 1998 Urges NRC to Revoke Operating Licenses for Indian Point Nuclear Generating Station,Units 2 & 3 & Not Renew OL for Unit 1 ML20154A1391998-09-22022 September 1998 Informs That Effective 980724,AA Blind Assumed Position of Vice President,Nuclear Power & Ja Baumstark Assumed Position of Vice President,Nuclear Power Engineering,Effective 980813 ML20153F0661998-09-18018 September 1998 Provides Response to Violations Noted in Insp Rept 50-286/98-05 & Proposed Imposition of Civil Penalty Dtd 980819.Corrective Actions:Existing Drawings for Spare Switchgear Cubicles Have Been Revised ML20151W4871998-09-10010 September 1998 Informs That as Part of NRC Probabilistic Risk Assessment Implementation Plan,Commission Assigned Two Senior Reactor Analysts (Sras) to Each Regional Ofc.T Shedlosky & J Trapp Has Been Assigned as SRAs for Region I ML20151W9511998-09-10010 September 1998 Informs That as Part of NRC PRA Implementation Plan, Commission Has Assigned Two Senior Reactor Analysts (Sras) to Regional Ofc.T Shedlosky & J Trapp Has Been Assigned SRAs Duties for Region I ML20155F4391998-08-26026 August 1998 Forwards Demand for Info,Being Issued to Enable NRC to Fully Understand Recipient Views on Facts & Circumstances Surrounding Allegedly False Info Provided to Two NRC-licensed Activities ML20238F5151998-08-26026 August 1998 First Partial Response to FOIA Request for Documents. Documents Listed in App a Being Released in Entirety. Documents Listed in App B Being Withheld in Part (Ref FOIA Exemption 6) IR 05000286/19980051998-08-19019 August 1998 Discusses Insp Rept 50-286/98-05 on 980528-0612 & Forwards NOV & Proposed Imposition of Civil Penalty in Amount of $55,000.Most Significant Violation Involved Failure, Following Design Mod in Oct 1997 ML20237B1001998-08-0505 August 1998 Responds to NRC Re Violations Noted in Insp Repts 50-247/97-13,50-247/97-15,50-247/98-02 & Investigation Rept 1-97-038,respectively.Corrective Actions:Acted Promptly to Assure Conforming to Testing Requirements ML20236X8511998-07-31031 July 1998 Forwards Rept Re Projection of Ability to Pay Retrospective Premium Adjustment for Period 980801-990731,per 10CFR140.21 ML20236V4211998-07-13013 July 1998 Forwards SER Approving Topical Repts WCAP-14333P & WCAP-14334NP (Proprietary & non-propiretary, PRA of RPS & ESFAS Test Times & Completion Times ML20236Q1431998-07-0808 July 1998 Responds to Administrative Ltr 98-03 Re Operating Reactor Licensing Action Estimates IR 05000247/19970131998-07-0606 July 1998 Discusses Insp Repts 50-247/97-13,50-247/97-15 & 50-247/98-02 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000 ML20238F5231998-06-29029 June 1998 FOIA Request for Documents Re NRC Office of Investigation Rept 1-97-038,meeting Minutes of Summary of Enforcement Conference on 980506 & Meeting Minutes or Summary of 980520 Predecisional Enforcement Conference ML20154Q1831998-06-29029 June 1998 FOIA Request for Documents Re NRC OI Rept 1-97-038,meeting Minutes of Summary of Enforcement Conference on 980506 & Meeting Minutes or Summary of 980520 Predecisional Enforcement Conference ML20236J9871998-06-24024 June 1998 First Final Response to FOIA Request for Documents.Documents Listed in App a Already Available in Pdr.Documents Listed in App B Being Released in Entirety ML20248F2891998-05-26026 May 1998 Ltr Contract:Task Order 8, Indian Point 2,A/E Follow-up Insp, Under Contract NRC-03-98-021 ML20248L9861998-05-21021 May 1998 Forwards Rev 7 to Security Force Training & Qualification Plan.Review to Verify Receipt of Revised Plan & Sign & Return Receipt Ack Form Provided ML20247M6951998-05-20020 May 1998 Forwards RAI Re GL 96-06, Assurance of Equipment Operability & Containment Integrity During Design-Basis Accident Conditions, for Plant,Unit 2 1999-09-02
[Table view] Category:OUTGOING CORRESPONDENCE
MONTHYEARML20217B3331999-10-0707 October 1999 Responds to 990825 Telephone Call Re Presense of Polychlorinated Biphenyl Wastes at Plant,Unit 1 ML20211N0681999-09-0202 September 1999 Informs That Commission Requested Publication of Notice of Consideration of Issuance of Amend to Fol,Proposed NSHC Determination & Opportunity for Hearing. Amend Changes Senior Reactor License Requirement for Operations Manager ML20209B6611999-06-29029 June 1999 Returns Recently Submitted Renewal Applications,Nrc Form 398,for Three Reactor Operators,As They Are Not Completed Properly.List of Docket Numbers & Block Numbers That Contain Incorrect Info & Block Numbers Not Completed.Without Encls ML20207D1861999-05-27027 May 1999 Informs That Effective 990328,NRC Office of NRR Underwent Reorganization.Mt Masnik Section Chief for Indian Point Station,Unit 1.JL Minns Remains Primary Contact for All Routine Licensing & Administrative Matters.Chart Encl ML20204J9971999-03-0909 March 1999 Forwards Insp Rept 50-003/98-19 on 981130-990222.No Violations Noted ML20203B9001999-02-0808 February 1999 First Partial Response to FOIA Request for Documents. Forwards Documents Listed in App a Already Available in PDR, Documents in App B Released in Entirety & Documents in App C Being Withheld in Part (Ref Exemption 6) ML20202J6171999-02-0505 February 1999 Forwards Transcript from 990120 Public Meeting Held in Peekskill,Ny Re Decommissioning ML20198E9561998-12-21021 December 1998 Forwards Order Prohibiting Involvement in NRC Licensed Activities Re Deliberate Misconduct in Violation of Regulation When False Info Was Provided to Two NRC Licensees ML20198C2371998-12-15015 December 1998 Ltr Contract:Task Order 237, Review & Evaluation of Indian Point 3 Nuclear Power Plant Application for Conversion to Improved TS, Under Contract NRC-03-95-026 ML20198C3251998-12-11011 December 1998 Responds to ,Responding to NRC Ltr Re Concerns Raised About Potential Chilling Effect from Temp Denial of Site Access to Employee Raising Safety Issues to Util Senior Mgt ML20155H2901998-11-0303 November 1998 Responds to to Lj Callan Expressing Concern About Continued Operation of Indian Point Nuclear Generating Station.Explanation Why NRC Do Not Think Revoking OLs for Indian Point Units 2 & 3 Justified,Provided ML20154Q1761998-10-21021 October 1998 Second Final Response to FOIA Request for Documents. Documents Listed in App C Being Withheld in Part (Ref FOIA Exemption 7) ML20154L8031998-10-16016 October 1998 Ack Receipt of & Payment in Amount of $55,000 in Electronic Funds for Civil Penalty Proposed by NRC in .Corrective Actions Will Be Examined During Future Insp ML20151W9511998-09-10010 September 1998 Informs That as Part of NRC PRA Implementation Plan, Commission Has Assigned Two Senior Reactor Analysts (Sras) to Regional Ofc.T Shedlosky & J Trapp Has Been Assigned SRAs Duties for Region I ML20151W4871998-09-10010 September 1998 Informs That as Part of NRC Probabilistic Risk Assessment Implementation Plan,Commission Assigned Two Senior Reactor Analysts (Sras) to Each Regional Ofc.T Shedlosky & J Trapp Has Been Assigned as SRAs for Region I ML20238F5151998-08-26026 August 1998 First Partial Response to FOIA Request for Documents. Documents Listed in App a Being Released in Entirety. Documents Listed in App B Being Withheld in Part (Ref FOIA Exemption 6) ML20155F4391998-08-26026 August 1998 Forwards Demand for Info,Being Issued to Enable NRC to Fully Understand Recipient Views on Facts & Circumstances Surrounding Allegedly False Info Provided to Two NRC-licensed Activities IR 05000286/19980051998-08-19019 August 1998 Discusses Insp Rept 50-286/98-05 on 980528-0612 & Forwards NOV & Proposed Imposition of Civil Penalty in Amount of $55,000.Most Significant Violation Involved Failure, Following Design Mod in Oct 1997 ML20236V4211998-07-13013 July 1998 Forwards SER Approving Topical Repts WCAP-14333P & WCAP-14334NP (Proprietary & non-propiretary, PRA of RPS & ESFAS Test Times & Completion Times IR 05000247/19970131998-07-0606 July 1998 Discusses Insp Repts 50-247/97-13,50-247/97-15 & 50-247/98-02 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000 ML20236J9871998-06-24024 June 1998 First Final Response to FOIA Request for Documents.Documents Listed in App a Already Available in Pdr.Documents Listed in App B Being Released in Entirety ML20248F2891998-05-26026 May 1998 Ltr Contract:Task Order 8, Indian Point 2,A/E Follow-up Insp, Under Contract NRC-03-98-021 ML20247M6951998-05-20020 May 1998 Forwards RAI Re GL 96-06, Assurance of Equipment Operability & Containment Integrity During Design-Basis Accident Conditions, for Plant,Unit 2 ML20247L1511998-05-15015 May 1998 Informs That Author Writing to Confirm Westinghouse Onwers Group Participation in Forthcoming 980612 Briefing to Commissioners of NRC in Rockville,Md & to Provide Background & Guidance for Briefing ML20203K5921998-02-26026 February 1998 Ack Receipt of Transmitting Changes to Physical Security Plan for Plant.Approval by NRC Is Not Required IAW 50.54(p) ML20199E0291997-11-19019 November 1997 Ack Receipt of & Wire Transfer for $110,000 in Payment for Civil Penalties Proposed by NRC in . Corrective Actions Will Be Examined During Future Insp IR 05000247/19970081997-10-0707 October 1997 Discusses Insp Rept 50-247/97-08 on 970616 & 0721 & Forwards Notice of Violation & Proposed Imposition of Civil Penalty in Amount of $110,000 ML20217C0931997-09-30030 September 1997 Ack Receipt of & Payment for Civil Penalty Proposed by NRC in .C/As Will Be Examined During Future Insps ML20211D3561997-09-23023 September 1997 First Partial Response to FOIA Request for Documents.Records Subj to Request Encl & Identified in App A.Addl Records Being Reviewed & Notification Will Be Provided Upon Completion IR 05000286/19970801997-08-19019 August 1997 Discusses Insp Rept 50-286/97-80 on 970407-0501 & Forwards NOV & Proposed Imposition of Civil Penalty in Amount of $55,000 ML20149K9711997-07-29029 July 1997 Ack Receipt of & Payment of $205,000 for Civil Penalty Proposed by NRC in .Violation Retracted Due to Licensee Disagreement ML20211D4191997-06-19019 June 1997 Discusses 930227 Shutdown of Plant,Unit 3.NRC Concluded That Sufficient Progress Has Been Made to Support Safe Plant Restart & Power operations.CAL-1-93-09 Issued on 930617, Which Documented Util Restart Commitments ML20140G3831997-06-0909 June 1997 Informs of Individual Exam Results for Applicants on Initial Exam Conducted on 970519-21 at Facility.Completed ES-501-2 Results Summary & Individual Results ES-303-1 & 303-2 Encl. W/O Encl ML20138C7461997-04-23023 April 1997 Forwards Amend 191 to License DPR-26 & Safety Evaluation. Amend Revises TS Sections 3.3 & 4.5 to Allow Deletion of Requirement to Utilize Sodium Hydroxide as Additive in Post Accident Containment Spray Sys ML20134N6141997-02-19019 February 1997 Responds to Re Proposed Corporate Reorganization of Consolidated Edison for Indian Point Units 1 & 2. Ltr Deemed Application for Consent Under 10CFR50.80 & Referred to NRC Staff for Consideration ML20134M8901997-02-19019 February 1997 Eighth Partial Response to FOIA Request for Documents. Records in App O Encl & Already Available in Pdr.App P Records Being Made Available in PDR ML20134H6271997-02-10010 February 1997 Fifth Partial Response to FOIA Request for Documents.Records in App I Encl & Available in Pdr.App J Records Withheld in Part (Ref FOIA Exemption 5) & App K Records Completely Withheld (Ref FOIA Exemption 5) ML20134N6451997-01-0909 January 1997 Responds to to Jm Taylor Re Proposed Corporate Reorganization of Consolidated Edison Co of Ny for Indian Point Units 1 & 2.Ltr of 961224 Deemed Application for Consent Under 10CFR50.80 & Referred for Consideration ML20133F7541997-01-0808 January 1997 Final Response to FOIA Request for Documents.Records in App a Encl & Available in Pdr.App B Records Being Withheld in Part (Ref FOIA Exemption 6) ML20128P2631996-10-11011 October 1996 Ltr Contract:Task Order 105, Indian Point 2 Ipap, Under Contract NRC-03-93-036 ML20129G6121996-09-24024 September 1996 Second Partial Response to FOIA Request for Documents. Forwards Documents Listed in App C,E,F & G.Documents Available in Pdr.App E,F & G Documents Partially Withheld Ref FOIA Exemptions 4 & 6.App D Record Listed as Copyright ML20134B7681996-06-10010 June 1996 Forwards Director'S Decision 96-06 Denying 960518 Requests Re Immediate Suspension of Operating Licenses for Indian Point Nuclear Generating Units 2 & 3 ML20211D9231995-11-0707 November 1995 Responds to 951020 Postcard,Requesting Transcript of 951018 Public Meeting in Buchanan,Ny.Meeting Was Not Transcribed. Copy of Presentation by NYPA at Meeting Encl ML20133F7781995-07-11011 July 1995 Ack Receipt of Re Restart of Plant NPP in Westchester County in New York ML20211F0161995-01-12012 January 1995 Forwards Copy of Rev & Status Update 3 of Plant,Unit 3 Restart Action Plan ML20134P2921994-12-22022 December 1994 Responds to Questions Presented in to G Gordon Re New York Regulatory Jurisdiction at Plant,Unit 1 ML20058E1321993-11-23023 November 1993 Forwards Insp Rept 50-247/93-26 on 931108-12.No Violations Noted ML20059M8261993-11-16016 November 1993 Discusses Proposed Rule for Protection Against Malevolent Use of Vehicles at Facility.Safeguards Info Encl.W/O Encl ML20059M8561993-11-16016 November 1993 Forwards Safeguards Info Ref in Preliminary Draft Guide Which Provides Proposed Characteristics of Design Basis Vehicle.W/O Encl ML20059K7361993-11-0505 November 1993 Forwards Util 931015 Response to NRC Request for Info Re Employee Safety Concerns at Unit 3 1999-09-02
[Table view] |
Text
_ _ _ - _ _ _ _ _ _ _ - - .____ __-______ ._ _ --. _.
j May 20,-1998 l
Mr. Paul H. Kinkel Vice President, Nuclear Power Consolidated Edison Company i of New York, Inc. l Broadway and Bleakley Avenue i Buchanan, NY 10511 l
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE GL 96-06 RESPONSE FOR INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 (TAC NO. M96822) I aar Mr. Kinkel: l l
Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment >
l Integrity During Design-Basis Accident Conditions," dated September 30,1996, included a i l
request for licensees to evaluate cooling water systems that serve containment air coolers to I assure that they are not vulnerable to waterhammer and two-phase flow conditions. l l
Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and l l
two-phase flow issues for Indian Point Unit 2 in a letter dated January 28,1997, in order to i
complete our review of your resolution of these issues, we will require additional information as i discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at l l
301-415-1421.
i I
Sincerely, Original Signed by: !
Jefferey F. Harold, Project Mancger !
Project Directorate 1-1 Division of Reactor Projects - 1/11 9805260340 9805-20 Office of Nuclear Reactor Regulation PDR ADOCK 05000247 P PDR ,
(
Docket No. 50-247
(
Enclosure:
As stated I cc w/ enc!: See next page
. DISTRIBUTION: h, mD Cf' 45 IDodet FNe' J. Zwolinski (A) J. Harold L
~~ 7' GIl pa pO(
PUBLIC PDI-1 R/F S. Bajwa S. Little OGC ACRS 9 1 l
DOCUMENT NAME:G:\lP2\lP296822.RAI To receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E"
= Copy with attachment / enclosure "N" = No copy OFFICE FM:PDI 1 , f lE LA:PCl*1 4 N l D:PDi 1 ,ffA l l l l NAME JHaro M [ N" $little M SBeiwa M A DATE 05/70/% ' ' 05/ 2 0/98 05/ )f/98 05/ /98 05/ /98 Official Record Copy
May 20, 1998 5 1 Mr. Paul H. Kinkel Vice President, Nuclear Power Consolidated Edison Company of New York, Inc.
Broadway and Bleakley Avenue Buchanan, NY 10511
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE GL 96-06 RESPONSE FOR INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 (TAC NO. M96822)
Dear Mr. Kinkel:
)
Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment Integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions.
Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for Indian Point Unit 2 in a letter dated January 28,1997. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421.
Sincerely, Original Signed by:
Jefferey F. Harold, Project Manager Project Directorate 1-1 Division of Reactor Projects - 1/11 Office of Nuclear Reactor Regulation Docket No. 50-247
Enclosure:
As stated cc w/ encl: See next page DISTRIBUTION:
l Docket File J. Zwolinski (A) J. Harold PUBLIC S. Bajwa OGC
- f. PDI-1 R/F S. Little ACRS DOCUMENT NAME:G:\lP2\lP296822.RAI To rec:ive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E"
= C py with attachment / enclosure "N" = No copy l 0FFICE PM:PDI 1 , , lE LA:PDI 1 4N l D:PDI-1 ,fff l l I l NAME JHaroRIl/ d 5Little N' SBajwa P A DATE 05/2 0 / 4 05/ dV98 05/20/98 05/ /98 05/ /98 Official Record Copy l
1
- p cero y t UNITED STATES Y
j 2
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 30566-0001
% . . . . . p' May 20, 1998 Mr. Paul H. Kinkel '
Vice President, Nuclear Power Consolidated Edison Company of New York, Inc.
Broadway and Bleakley Avenue Buchanan, NY 10511
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RELATED TO THE GL 96-06 RESPONSE FOR INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 (TAC NO. M96822)
Dear Mr. Kinkel:
Generic Letter (GL) 96-06, " Assurance of Equipment Operability and Containment integrity During Design-Basis Accident Conditions," dated September 30,1996, included a request for licensees to evaluate cooling water systems that serve containment air coolers to assure that they are not vulnerable to waterhammer and two-phase flow conditions.
Consolidated Edison Company (the licensee) provided its assessment of the waterhammer and two-phase flow issues for indian Point Unit 2 in a letter dated January 28,1997. In order to complete our review of your resolution of these issues, we will require additional information as discussed in the enclosure. We ask that you provide this information by July 30,1998, in order to support our review schedule for GL 96-06. If you have any question, please call me at 301-415-1421.
Sincerely,
/
d , b' '
Jefferey F. Harold, Project Manager Project Directorate 1-1 Division of Reactor Projects - 1/ll Office of Nuclear Reactor Regulation I
Docket No. 50-247
Enclosure:
As stated cc w/ encl: See next page
Paul H. Kinkel Indian Point Nuclear Generating
, Consolidated Edison Company Station Units 1/2 of New York, Inc.
cc:
Mayor, Village of Buchanan Charles Donaldson, Esquire' 236 Tate Avenue Assistant Attomey General Buchanan, NY 10511 New York Department of Law 120 Broadway Mr. F. William Valentino, President New York, NY 10271 New York State Energy, Research, and Development Authority Ms. Charlene D. Faison, Director Corporate Plaza West Nuclear Licensing 286 Washington Ave. Extension Power Authority of the State Albany, NY 12203-6399 of New York 123 Main Street Mr. Charles W. Jackson White Plains, NY 10601 Manager of Nuclear Safety and Licensing Mr. Walter Stein Consolidated Edison Company Secretary - NFSC of New York, Inc. Consolidated Edison Company Broadway and Bleakley Avenue of New York, Inc.
Buchanan, NY 10511 4 Irving Place - 1822 New York, NY 10003 Senior Resident inspector U. S. Nuclear Regulatory Commission Regional Administrator, Region i P.O. Box 38 U. S. Nuclear Regulatory Commission Buchanan, NY 10511 475 Allendale Road King of Prussia, PA 19406 Mr. Brent L. Brandenburg Assistant General Counsel Mr. Paul Eddy Consol; dated Edison Company New York State Department of of New York, Inc. Public Service 4 Irving Place - 1822 3 Empire State Plaza,10th Floor New York, NY 10003 Albany, NY 12223 L
l l
l
8 REQUEST FOR ADDITIONAL INFORMATION FOR RESOLUTION OF GL 96-06 ISSUES AT INDIAN POINT UNIT 2 The following additional information is requested in order to complete our review:
- 1. If a methodology other than that discussed in NUREG/CR-5220, " Diagnosis of Condensation-induced Waterhammer," was used in evaluating the effects of waterhammer, describe this altemate met 5odology in detail. Also, explain why this methodology is applicable and gives conservative results for 1r point Unit 2 (typically accomplished through rigorous plant-specific modeling, testing, and analysis).
- 2. For both the waterhammer and two-phase flow analyses, provide the following i information:
- a. Identify any computer codes that were used in the waterhammer and two-phase flow analyses and describe the methods used to bench mark the codes for the specific loading conditions involved (see Standard Review Plan Section 3.9.1). ,
- b. Describe and justify all assumptions and input parameters (including those used in any computer codes) such as amplifications due to fluid structure interaction, cushioning, speed of sound, force reductions, and mesh sizes, and explain why the values selected give conservative results. Also, provide justification for omitting any effects that may be relevant to the analysis (e.g., fluid structure interaction, flow induced vibration, erosion).
- c. Provide a detailed description of the " worst case" scenarios for waterhammer and two-phase flow, taking into consideration the complete range of event possibilities, system configurations, and parameters. For example, all waterhammer types and water slug scenarios should be considered, as well as temperatures, pressures, flow rates, load combinations, and potential component failures. Additional examples include:
. the effects of void fraction on flow balance and heat transfer, e the consequences of steam formation, transpod, and accumulation;
- cavitation, resonance, and fatigue effects; and
While the last three items (listed above) are important considerations for assuring i that system integrity will be maintained during two-phase flow conditions, they were not discussed in the licensee's response. Also, NUREG/CR-6031, " Cavitation Guide for Control Valves," may.be helpful in addressing some aspects of the two-phsse flow analyses.
i Enclosure ,
l t - - _ _ _ _ _ _ _ _ _ _ J
_ _ _____ - _ ___=__ ______ _ _ __ _ _ _ - _ - _ __ _ _ _ __
L .,-
O t ,
, .i l
! d. Confirm that the analyses included a complete failure modes and effects analysis (FMEA) for all components (including electrical and pneumatic failures) that could impact performance of the cooling water system and confirm that the FMEA is
, documented and available for review, or explain why a complete and fully f
documented FMEA was not perfortred.
- e. Explain and justify all uses of " engineering judgement."
- 3. Determine the uncertainty in the waterhammer and two-phase flow analyses, explain how l the uncertainty was determined, and how it was accounted for in the analyses to assure l conservative results for Indian Point Unit 2.
l 4. Confirm that the waterhammer and two-phase flow loading conditions do not exceed any design specifications or recommended service conditions for the piping system and
- . components, including those stated by equipment vendors; and confirm that the system will continue to perform its design-basis functions as assumed in the safety analysis report for the facility.
- 5. Provide a simplified diagram of the affected system, showing major components, active components, relative elevations, lengths of piping runs, and the location of any orifices and flow restrictions.
l I
l l
l
_ _ _ _ _ _ _ _ _ - _ _ - _ _ _ _ ___