ML20204J997
| ML20204J997 | |
| Person / Time | |
|---|---|
| Site: | Indian Point |
| Issue date: | 03/09/1999 |
| From: | Ronald Bellamy NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Blind A CONSOLIDATED EDISON CO. OF NEW YORK, INC. |
| Shared Package | |
| ML20204K000 | List: |
| References | |
| 50-003-98-19, 50-3-98-19, NUDOCS 9903300205 | |
| Download: ML20204J997 (3) | |
See also: IR 05000003/1998019
Text
1
l
1
.
March 9,1999
I
Mr. A. Alan Blind
Vice President - Nuclear Power
Consolidated Edison Company
of New York, Inc.
Indian Point 1 Station
Broadway & Bleakley Avenue
Buchanan, NY 10511
SUBJECT:
NRC INSPECTION REPORT 50-003/98-019
Dear Mr. Blind:
On February 22,1999, the NRC completed an inspection at the Indian Point Unit 1 reactor
facility. The results of that inspection were discussed with members of your staff at the exit
meeting held on December 2,1998 and by tele-conference on February 22,1999. The
enclosed report presents the results of that inspection.
During the three-month period covered by this inspection period, your co iduct of activities
during the limited decommissioning at the Indian Point Unit 1 facility was safety focused.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice,," a copy of this letter and its
enclosure will be placed in the NRC Public Document Room.
4
Sincerely,
Original Signed by:
Ronald R. Be!iamy, Chief
Decommissioning and Laboratory Branch
Division of Nuclear Materials Safety
Docket No:
50-003
License No.
1
Enclosure:
NRC Inspection Report No. 50-003/98-019
9903300205 990309
'
ADOCK 05000003
G
avuv--
'F
,
'
je/
OFFJCIAL RECORD COPY
{
'
)
_
3
-
-
A. Blind
-2-
Indian Point Unit 1
cc w/ encl:
N. Cams, Senior Vice President - Nuclear Operations
C. J9ckson, Manager, 'mlear Safety and Licensing
B. Brandenburg, Assistant General Counsel
C. Faison, Director, Nuclear Licensing, NYPA
= D. Moffei, Project Manager, Unit 1
P. Kokolakis, Director Nuclear Licensing
l
T. Rose, Electric Division, Department of Public Service, State of New York
C. Donaldson, Esquire, Assistant Attomey General, New York Department of Law
.
J. Spath, NYS Energy Research and Development Authority
-
A. Donohew, Mayor, Village of Buchanan
]
P. Eddy, Electric Division, Department of Public Service, State of New York
J. Baumstark, Vice President, Nuclear Power Engineering
State of New York, SLO Designee
l
I
l
n
-
.
A. Blind
-3-
Indian Point Unit 1
Distribution w/ encl:
H. Miller, RA/J. Wiggins, DRA
' Region I Docket Room (with concurrences)
' Nuclear Safety information Center (NSIC)
RtBLD*
DNMS Director, Region 1
DNMS Deputy Director, Region i
Distribution w/enci (VIA E-Mall):
K. Kennedy, OEDO
J. Minns, NRR
M. Masnik, NRR
M. Callahan, OCA
D. Screnci, PAO
N. Sheehan, PAO
Inspection Program Branch, NRR (IPAS)
DOCDESK
DOCUMENT NAME: B:\\DNMS Documents \\lnsp Letter \\lndian Point 1 Insp Report 98-019.wpd
To receive a copy of thpocument, Indicate in the box: "C" = Copy without
i
attachment / enclosure "Er d Copy with attachment / enclosure "N" = No copy
OFFICE
Rl/DNMS
[ JJE
Rl/DNMS
jE
l ~
NAME
ADimitriadis K/
RBellamy P
DATE
3/9/99
F
0340/99
OFFICIAL RECORD COPY
v
,