ML17262A723: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(13 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17262A723
| number = ML17262A723
| issue date = 09/20/2017
| issue date = 09/20/2017
| title = FENOC Fleet - Results of Acceptance Review of the Exemption Request Exemption from the Definition of Physical Barrier in 10 CFR 73.2 for Physical Security Plans (CAC Nos. MG0010, MG0011, MG0012, and MG0013)
| title = FENOC Fleet - Results of Acceptance Review of the Exemption Request Exemption from the Definition of Physical Barrier in 10 CFR 73.2 for Physical Security Plans
| author name = Vaidya B K
| author name = Vaidya B
| author affiliation = NRC/NRR/DORL/LPLIII
| author affiliation = NRC/NRR/DORL/LPLIII
| addressee name = Belcher S L
| addressee name = Belcher S
| addressee affiliation = FirstEnergy Nuclear Operating Co
| addressee affiliation = FirstEnergy Nuclear Operating Co
| docket = 05000334, 05000440, 07200014, 07200069, 07201043
| docket = 05000334, 05000440, 07200014, 07200069, 07201043
| license number = DPR-066, NPF-003, NPF-058, NPF-073
| license number = DPR-066, NPF-003, NPF-058, NPF-073
| contact person = Vaidya B K, 415-3308
| contact person = Vaidya B, 415-3308
| case reference number = CAC MG0010, CAC MG0011, CAC MG0012, CAC MG0013
| case reference number = CAC MG0010, CAC MG0011, CAC MG0012, CAC MG0013
| document type = Acceptance Review Letter, Letter
| document type = Acceptance Review Letter, Letter
| page count = 3
| page count = 3
| project = CAC:MG0013, CAC:MG0010, CAC:MG0012, CAC:MG0011
| project = CAC:MG0010, CAC:MG0011, CAC:MG0012, CAC:MG0013
| stage = Acceptance Review
| stage = Acceptance Review
}}
}}


=Text=
=Text=
{{#Wiki_filter:
{{#Wiki_filter:UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 20, 2017


==SUBJECT:==
==SUBJECT:==
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 20, 2017 FENOC FLEET-BEAVER VALLEY POWER STATION, UNIT NOS. 1, AND 2; DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1, AND PERRY NUCLEAR POWER PLANT, UNIT NO. 1 -RESULTS OF ACCEPTANCE REVIEW OF THE EXEMPTION REQUEST RE: EXEMPTION FROM THE DEFINITION OF PHYSICAL BARRIER IN 10 CFR 73.2 FOR PHYSICAL SECURITY PLANS (CAC NOS. MG0010, MG0011, MG0012, AND MG0013)  
FENOC FLEET-BEAVER VALLEY POWER STATION, UNIT NOS. 1, AND 2; DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1, AND PERRY NUCLEAR POWER PLANT, UNIT NO. 1 - RESULTS OF ACCEPTANCE REVIEW OF THE EXEMPTION REQUEST RE: EXEMPTION FROM THE DEFINITION OF PHYSICAL BARRIER IN 10 CFR 73.2 FOR PHYSICAL SECURITY PLANS (CAC NOS. MG0010, MG0011, MG0012, AND MG0013)


==Dear Mr. Belcher:==
==Dear Mr. Belcher:==
By letter dated July 19, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML 17200D139), FirstEnergy Nuclear Operating Company (FENOC, the licensee) submitted an exemption request for Renewed Facility Operating Licenses for the Beaver Valley Power Station, Unit Nos. 1 and 2, Davis-Besse Nuclear PowerStation, Unit No. 1, and Facility Operating License for Perry Nuclear Power Plant, Unit 1. The licensee requested the permanent exemption pursuant to Title 1 O of the Code of Federal Regulations (10 CFR) Section 73.5, "Specific exemptions," from a requirement of 10 CFR 73.2, "Definitions" for "Physical Barrier." The regulation requires, in part, fences topped by three strands or more of barbed wire or similar material on brackets be angled inward or outward between 30 and 45 degrees from the vertical. An exemption is requested since not all protected area physical barrier fencing sections meet this requirement. The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC or Commission) staff's acceptance review of the proposed exemption request. The acceptance review was performed to determine if there is proper regulatory basis and sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant. Section 73.5 of 10 CFR, "Specific exemptions," states that the Commission may grant exemptions from the requirements of the regulations of this part provided the following specific criteria are met: (1) the exemption is authorized by law, (2) the exemption will not endanger life or property or the common defense and security, and (3) the exemption is otherwise in the public interest. Additionally, the categorical exclusion requirement in 10 CFR 51.22(c)(25), states that to meet the requirements for the categorical exclusion in accordance with 1 O CFR 51.22(c)(25), the exemption must meet the following: (i) no significant hazards consideration determination ; (ii) no significant change in the types or significant increase in the amounts of any effluents that may be released offsite; (iii) no significant increase in individual or cumulative public or occupational radiation exposure; (iv) no significant construction impact; (v) no significant increase in the potential for or consequences from radiological accidents; and (vi) the S. Belcher  requirements from which the exemption is sought involves safeguards plans or other requirements of an administrative, managerial or organizational nature. The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed you will be advised by separate correspondence. Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately 400 hours to complete. The staff expects to complete this review by the requested date of July 31, 2018. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates will be communicated, during the routine interactions with the assigned project manager. These estimates are based on the NRC staff's initial review of the application and they could change due to several factors, including requests for additional information, unanticipated addition of scope to the review, and review by NRC advisory committees or hearing-related activities. Additional delay may occur if the submittal is provided to the NRC in advance or in parallel with industry program initiatives or pilot applications. If you have any questions, please contact me at (301) 415-3308. Sincerely, Bhalchandra Vaidya, Project Manager Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-334, 50-346, 50-412, and 50-440 cc: Distribution via ListServ S. Belcher 


==SUBJECT:==
By letter dated July 19, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17200D139), FirstEnergy Nuclear Operating Company (FENOC, the licensee) submitted an exemption request for Renewed Facility Operating Licenses for the Beaver Valley Power Station, Unit Nos. 1 and 2, Davis-Besse Nuclear PowerStation, Unit No. 1, and Facility Operating License for Perry Nuclear Power Plant, Unit 1.
FENOC FLEET-BEAVER VALLEY POWER STATION, UNIT NOS. 1, AND 2; DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1, AND PERRY NUCLEAR POWER PLANT, UNIT NO. 1; -RESULTS OF ACCEPTANCE REVIEW OF THE EXEMPTION REQUEST RE: EXEMPTION FROM THE DEFINITION OF PHYSICAL BARRIER IN 10 CFR 73.2 FOR PHYSICAL SECURITY PLANS (CAC NOS. MG0010, MG0011, MG0012, AND MG0013) DATED SEPTEMBER 20, 2017 DISTRIBUTION: Public RidsNrrDorlLpl3 Resource RidsNrrLALRonewicz Resource RidsNrrPMDavisBesse RidsAcrsMailCenter Resource RidsRgn3MailCenter RidsNrrDorlLpl1 Resource RidsNrrLASRohrer Resource BVaidya, NRR RidsNrrPMBeaver Valley RidsOgcRp Resource RidsRgn1 MailCenter WRautzen, NRR/DLR/RERP RidsNrrDlrRerp Resource RidsNsirDpcpRsb Resource DGordon, NSIR/DSP/RSB DHuyck, NSIR/DSO/SOSB ADAMS Accession No.: ML 17262A723 OFFICE DORL/LPL3/PM DORL/LPL3/LA DLR/RERP/BC(*) NAME BVaidya SRohrer BBeasley (WRautzen for) DATE 09/20/17 09/20/17 08/01/17 OFFICE DORL/LPL3/BC DORL/LPL3/PM NAME DWrona (KGreen for) BVaidya DATE 09/20/17 09/20/17 OFFICIAL RECORD COPY *by e-mail NSIR/DPCP/RSB/BC(*) ARivera (DGordon for) 07/28/17 
The licensee requested the permanent exemption pursuant to Title 1O of the Code of Federal Regulations (10 CFR) Section 73.5, "Specific exemptions," from a requirement of 10 CFR 73.2, "Definitions" for "Physical Barrier." The regulation requires, in part, fences topped by three strands or more of barbed wire or similar material on brackets be angled inward or outward between 30 and 45 degrees from the vertical. An exemption is requested since not all protected area physical barrier fencing sections meet this requirement.
}}
The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC or Commission) staff's acceptance review of the proposed exemption request. The acceptance review was performed to determine if there is proper regulatory basis and sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.
Section 73.5 of 10 CFR, "Specific exemptions," states that the Commission may grant exemptions from the requirements of the regulations of this part provided the following specific criteria are met: (1) the exemption is authorized by law, (2) the exemption will not endanger life or property or the common defense and security, and (3) the exemption is otherwise in the public interest. Additionally, the categorical exclusion requirement in 10 CFR 51.22(c)(25),
states that to meet the requirements for the categorical exclusion in accordance with 10 CFR 51.22(c)(25), the exemption must meet the following: (i) no significant hazards consideration determination ; (ii) no significant change in the types or significant increase in the amounts of any effluents that may be released offsite; (iii) no significant increase in individual or cumulative public or occupational radiation exposure; (iv) no significant construction impact; (v) no significant increase in the potential for or consequences from radiological accidents; and (vi) the
 
S. Belcher                                    requirements from which the exemption is sought involves safeguards plans or other requirements of an administrative, managerial or organizational nature.
The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed you will be advised by separate correspondence. Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately [[estimated NRC review hours::400 hours]] to complete. The staff expects to complete this review by the requested date of July 31, 2018. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates will be communicated, during the routine interactions with the assigned project manager.
These estimates are based on the NRC staff's initial review of the application and they could change due to several factors, including requests for additional information, unanticipated addition of scope to the review, and review by NRC advisory committees or hearing-related activities. Additional delay may occur if the submittal is provided to the NRC in advance or in parallel with industry program initiatives or pilot applications.
If you have any questions, please contact me at (301) 415-3308.
Sincerely,
                                                ~~
                                                ~
Bhalchandra Vaidya, Project Manager Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-334, 50-346, 50-412, and 50-440 cc: Distribution via ListServ
 
ML17262A723                                        *by e-mail OFFICE       DORL/LPL3/PM       DORL/LPL3/LA DLR/RERP/BC(*)         NSIR/DPCP/RSB/BC(*)
NAME         BVaidya             SRohrer       BBeasley (WRautzen for) ARivera (DGordon for)
DATE         09/20/17           09/20/17     08/01/17                07/28/17 OFFICE       DORL/LPL3/BC       DORL/LPL3/PM NAME         DWrona (KGreen for) BVaidya DATE         09/20/17           09/20/17}}

Latest revision as of 12:51, 18 March 2020

FENOC Fleet - Results of Acceptance Review of the Exemption Request Exemption from the Definition of Physical Barrier in 10 CFR 73.2 for Physical Security Plans
ML17262A723
Person / Time
Site: Beaver Valley, Davis Besse, Perry, 07201043, 07200069
Issue date: 09/20/2017
From: Bhalchandra Vaidya
Plant Licensing Branch III
To: Belcher S
FirstEnergy Nuclear Operating Co
Vaidya B, 415-3308
References
CAC MG0010, CAC MG0011, CAC MG0012, CAC MG0013
Download: ML17262A723 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 September 20, 2017

SUBJECT:

FENOC FLEET-BEAVER VALLEY POWER STATION, UNIT NOS. 1, AND 2; DAVIS-BESSE NUCLEAR POWER STATION, UNIT NO. 1, AND PERRY NUCLEAR POWER PLANT, UNIT NO. 1 - RESULTS OF ACCEPTANCE REVIEW OF THE EXEMPTION REQUEST RE: EXEMPTION FROM THE DEFINITION OF PHYSICAL BARRIER IN 10 CFR 73.2 FOR PHYSICAL SECURITY PLANS (CAC NOS. MG0010, MG0011, MG0012, AND MG0013)

Dear Mr. Belcher:

By letter dated July 19, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML17200D139), FirstEnergy Nuclear Operating Company (FENOC, the licensee) submitted an exemption request for Renewed Facility Operating Licenses for the Beaver Valley Power Station, Unit Nos. 1 and 2, Davis-Besse Nuclear PowerStation, Unit No. 1, and Facility Operating License for Perry Nuclear Power Plant, Unit 1.

The licensee requested the permanent exemption pursuant to Title 1O of the Code of Federal Regulations (10 CFR) Section 73.5, "Specific exemptions," from a requirement of 10 CFR 73.2, "Definitions" for "Physical Barrier." The regulation requires, in part, fences topped by three strands or more of barbed wire or similar material on brackets be angled inward or outward between 30 and 45 degrees from the vertical. An exemption is requested since not all protected area physical barrier fencing sections meet this requirement.

The purpose of this letter is to provide the results of the U.S. Nuclear Regulatory Commission (NRC or Commission) staff's acceptance review of the proposed exemption request. The acceptance review was performed to determine if there is proper regulatory basis and sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

Section 73.5 of 10 CFR, "Specific exemptions," states that the Commission may grant exemptions from the requirements of the regulations of this part provided the following specific criteria are met: (1) the exemption is authorized by law, (2) the exemption will not endanger life or property or the common defense and security, and (3) the exemption is otherwise in the public interest. Additionally, the categorical exclusion requirement in 10 CFR 51.22(c)(25),

states that to meet the requirements for the categorical exclusion in accordance with 10 CFR 51.22(c)(25), the exemption must meet the following: (i) no significant hazards consideration determination ; (ii) no significant change in the types or significant increase in the amounts of any effluents that may be released offsite; (iii) no significant increase in individual or cumulative public or occupational radiation exposure; (iv) no significant construction impact; (v) no significant increase in the potential for or consequences from radiological accidents; and (vi) the

S. Belcher requirements from which the exemption is sought involves safeguards plans or other requirements of an administrative, managerial or organizational nature.

The NRC staff has reviewed your application and concluded that it does provide technical information in sufficient detail to enable the staff to complete its detailed technical review and make an independent assessment regarding the acceptability of the proposed amendment in terms of regulatory requirements and the protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the staff's ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed you will be advised by separate correspondence. Based on the information provided in your submittal, the NRC staff has estimated that this licensing request will take approximately 400 hours16.667 days <br />2.381 weeks <br />0.548 months <br /> to complete. The staff expects to complete this review by the requested date of July 31, 2018. If there are emergent complexities or challenges in our review that would cause changes to the initial forecasted completion date or significant changes in the forecasted hours, the reasons for the changes, along with the new estimates will be communicated, during the routine interactions with the assigned project manager.

These estimates are based on the NRC staff's initial review of the application and they could change due to several factors, including requests for additional information, unanticipated addition of scope to the review, and review by NRC advisory committees or hearing-related activities. Additional delay may occur if the submittal is provided to the NRC in advance or in parallel with industry program initiatives or pilot applications.

If you have any questions, please contact me at (301) 415-3308.

Sincerely,

~~

~

Bhalchandra Vaidya, Project Manager Plant Licensing Branch Ill Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-334, 50-346, 50-412, and 50-440 cc: Distribution via ListServ

ML17262A723 *by e-mail OFFICE DORL/LPL3/PM DORL/LPL3/LA DLR/RERP/BC(*) NSIR/DPCP/RSB/BC(*)

NAME BVaidya SRohrer BBeasley (WRautzen for) ARivera (DGordon for)

DATE 09/20/17 09/20/17 08/01/17 07/28/17 OFFICE DORL/LPL3/BC DORL/LPL3/PM NAME DWrona (KGreen for) BVaidya DATE 09/20/17 09/20/17