ML17208A116: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
(9 intermediate revisions by the same user not shown)
Line 2: Line 2:
| number = ML17208A116
| number = ML17208A116
| issue date = 02/25/2017
| issue date = 02/25/2017
| title = TSD 14-016 Rev 0, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
| title = Tsd 14-016 Rev 0, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
| author name = Farr H
| author name = Farr H
| author affiliation = EnergySolutions, Inc, ZionSolutions, LLC
| author affiliation = EnergySolutions, Inc, ZionSolutions, LLC
Line 15: Line 15:
| page count = 123
| page count = 123
}}
}}
=Text=
{{#Wiki_filter:ZionSolutions, LLC.
Technical Support Document TSD 14-016 Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State Revision 0 Originator: ___          _______________________ Date: __2/25/17__________
Harvey Farr Reviewer: ______________for DC per e-mail 02/23/17 Date:__ 2/25/17_________
David N. Carter Reviewer: ____________________________________ Date:__ 2/25/17________
Robert F. Yetter Approval: ____________________________________ Date: ___2/25/17________
Donald E. Williams Page 1 of 123
TSD 14-016 Revision 0 Summary of Changes in this Revision:
* Rev. 0 -Initial issuance.
Page 2 of 123
TSD 14-016 Revision 0 TABLE OF CONTENTS
: 1. PURPOSE ...................................................................................................................................... 7
: 2. DEFINITIONS .............................................................................................................................. 7
: 3. DISCUSSION ................................................................................................................................ 7 3.1.        General Void Space Volume and Surface Area Method.....................................7 3.2.        Preliminary MARSSIM Classification .............................................................7
: 4. CALCULATIONS ......................................................................................................................... 8 4.1. Containment Penetrations and Embedded Piping ..............................................8 4.2. Containment Incore Area Embedded Piping ...................................................11 4.3.        Main Steam and Tendon Tunnel Aerated Drain Piping ....................................12 4.4. Auxiliary Building Penetrations and Embedded Piping ...................................20 4.5.        Turbine Building Penetrations and Piping ......................................................44 4.1.        Circulating Water Intake Piping ....................................................................58 4.2.        Circulating Water Discharge Piping ..............................................................62 4.3. Crib House Penetrations and Embedded Piping ..............................................67 4.4.        Waste Water Treatment Facility Penetrations and Buried Piping ......................69 4.5.        Buried Piping Inventory ...............................................................................71 4.6.        Fuel Handling Building ...............................................................................71
: 5. CONCLUSION............................................................................................................................ 72
: 6. REFERENCES ............................................................................................................................ 74
: 7. ATTACHMENTS........................................................................................................................ 75 7.1.        Attachment A - Building Penetrations South .................................................75 7.2.        Attachment B - Building Penetrations North ..................................................75 7.3.        Attachment C - Building Penetrations East ....................................................75 7.4.        Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains ............75 7.5.        Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains.............75 7.6.        Attachment F - End State Penetration and Piping Inventory ............................75 7.7. Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 75 7.8. Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory ....................................................................................................75 7.9.        Attachment I - Auxiliary Building Affiliated Penetrations and Piping ..............75 7.10. Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 75 7.11. Attachment K - Waste Water Treatment Facility ............................................75 7.12. Attachment L - Crib House Penetrations and Piping .......................................75 7.13. Attachment M - Fuel Handling Building Affiliated Penetrations, Piping ...........75 7.14. Attachment N - Buried Pipe Penetrations and Piping Inventory ........................75 7.15. Attachment O - Circulating Water Intake Penetrations and Piping ...................75 7.16. Attachment P - Circulating Water Discharge Piping Inventory ........................75 LIST OF TABLES Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space .............................................................................................................................................. 10 Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes ............... 10 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes ............... 11 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume ............... 12 Page 3 of 123
TSD 14-016 Revision 0 Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2......................................................... 12 Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3......................................................... 12 Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4......................................................... 13 Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5 ..................................................................... 13 Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7 ..................................................................... 13 Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe .............................................................. 13 Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump ................................................ 14 Table 12 - Main Steam Tunnel Drain M9 Center Pipe ........................................................................... 14 Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7 ...................... 14 Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths ............................................. 15 Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10 .................... 15 Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217 ................... 16 Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths ............................................. 16 Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle .................................. 16 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space .............................................................................................................................................. 19 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space ............................................................................................................................. 19 Table 21 - 24" Safety Injection Pipe Segments A36 and A51 ................................................................ 26 Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths ................................................................................................................................................... 27 Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths ................................................................................................................................................... 28 Table 24 -A40 Unit 1 4" Drain Line Segment Lengths .......................................................................... 29 Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths ..................................................... 30 Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths ................................................. 31 Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths .............................................................. 31 Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths ..................................................... 32 Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths ................................................... 33 Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2" ................................................................. 33 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths .......................................... 34 Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths ................................ 34 Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths ................. 35 Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths ..................................................... 35 Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths........................................... 36 Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths ...................................................... 36 Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths
................................................................................................................................................................ 37 Table 38 - A58 OCT-061-2" Line Segment Lengths ............................................................................. 38 Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths ........................... 39 Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3" . 41 Table 41 - Service Water Supply Header Pipe Lengths C26 & C29 ...................................................... 43 Table 42 - Summary of Auxiliary Building Affiliated Penetrations ...................................................... 43 Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall .......................... 44 Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33 .................. 48 Table 45 - Estimated Lengths of T95 and T102. ................................................................................... 52 Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes ............ 55 Page 4 of 123
TSD 14-016 Revision 0 Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping ...................................................................................................................................................... 57 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes. ................................................................................................................................................. 58 Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes .... 58 Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers ....................................................................................................................... 60 Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128 ..................... 61 Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes .................................................................................................................................................. 62 Table 53 - 48 Inch Circulating Water Standpipe Lengths ...................................................................... 64 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths .............................................. 67 Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths .............................................. 67 Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay ....................... 67 Table 57 - Summary of Crib House Penetrations at Match Line AA .................................................... 68 Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space ....................................................................................................................................................... 69 Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces ..................................... 71 Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces . 72 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes ...... 73 TABLE OF FIGURES Figure 1 - Overall Layout of Containment Penetrations .......................................................................... 8 Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4 .......................................... 9 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping .................................................. 10 Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)....................................................................... 11 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210 ....................................................... 15 Figure 6 - Tendon Access Gallery Details (B-210) ................................................................................ 17 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466 ............................................................. 18 Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23. ............................................ 20 Figure 9 - M-107 Sh2 Excerpt Top View ............................................................................................... 21 Figure 10 - Side View Unit 1 Excerpt from B118 .................................................................................. 22 Figure 11 - Side View Unit 2 Excerpt from B-120 ................................................................................ 22 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107 ......................................... 23 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106..................... 24 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions ...................................................... 25 Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2 ................... 26 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall ....................................................... 27 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2 ................................ 29 Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2 ........................................... 30 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines ...................................... 31 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout ........................................................ 32 Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply ..................................... 34 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2 ............................................................ 37 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination .......................................................... 38 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path ........................................................... 39 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout .............................................................. 40 Page 5 of 123
TSD 14-016 Revision 0 Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines ................................... 40 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106. .................. 42 Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers .............................................................................................................................................. 42 Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106 ............................................. 44 Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104 ............................... 45 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103 ............................... 46 Figure 32 - Unit 2 North Diesel Oil Penetrations ................................................................................... 47 Figure 33 - Unit 1 South Diesel Oil Penetrations ................................................................................... 47 Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers ..................... 48 Figure 35 - Turbine Building East Wall Penetrations - North ................................................................ 50 Figure 36 - T95 and T102 Buried and Embedded Sections.................................................................... 51 Figure 37 - Turbine Building East Wall Penetrations - South ................................................................ 52 Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building 53 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105 ................................................... 54 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103 .......................... 56 Figure 41 - Circ Water Intake Supply to Condensers ............................................................................. 59 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127 ..................... 61 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2 .................................... 62 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel ........................................ 63 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100 .................. 64 Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100 ........................... 65 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return ........................................................ 66 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2 ................................................................ 68 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005 .. 70 Figure 50 - Top View Approximate Penetration Locations B-1024 ...................................................... 71 Page 6 of 123
TSD 14-016 Revision 0
: 1. PURPOSE The purpose of this document is to provide an inventory of the embedded piping, buried piping, and penetrations that will remain in the end state structures (i.e., below 588 foot elevation) at the Zion Nuclear Power Station (ZNPS). The document provides a basis for the estimated lengths and diameters, and also estimates the surface areas and void spaces associated with them. The document also provides the current planned end state (e.g., pipe removed from penetration or pipe remains in penetration). Penetrations along with elevation and reference drawings for the Unit 1 and 2 Containments, Auxiliary Building, Spent Fuel Building, Turbine Building and Crib House, Tendon Tunnels, Main Steam Tunnels, and the Waste Water Treatment Facility WWTF are summarized in Attachments A thru E. A final list if all piping and penetrations with estimated lengths, surface areas, and void space is provided in Attachment F.
: 2. DEFINITIONS Embedded Pipe - A pipe that is encased in concrete and that runs vertically through a concrete wall or horizontally through a concrete floor and is contained within a given building.
Buried Pipe - A pipe that runs through soil is defined as a buried pipe.
Pipe Penetration - A pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.
: 3. DISCUSSION 3.1. General Void Space Volume and Surface Area Method The use of the inside versus outside diameter varies depending on whether or not the piping is embedded and cannot be removed but will left in place and surveyed. If the piping is removed the outer diameter is used unless it is through a larger sleeve, in which case the inside diameter of the sleeve is used. The equation used for the inside surface area is Equation 1.
Equation 1 - Surface Area of Opening
                                                = 2 Where r = the pipe radius used (inner or outer as described above) or the sleeve radius used.
h = pipe length in same units as r.
The equation for the void space volume is Equation 2.
Equation 2 - Void Space Volume of Opening
                                                    =
3.2. Preliminary MARSSIM Classification A preliminary MARSSIM Classification was assigned to the piping and penetrations evaluated in this document. This classification was based upon knowledge of Pressurized Water Reactor systems and system contamination levels at Zion. Class 1 systems are those that have a high probability of a Page 7 of 123
TSD 14-016 Revision 0 Derived Concentration Guideline Level concentration being exceeded. The systems are those that contained high activity water, such as Waste Discharge lines, Spent Fuel Pool, fill drain and clean-up lines, Residual Heat Removal lines, etc. Class 2 MARSSSIM lines are those that have a 50%
probability of exceeding a DCGL. These are generally secondary systems with the potential for cross contamination from primary system to secondary system leaks, such as Component Cooling, Main Steam, Feedwater, etc. Class 3 systems have a less than 50% chance of exceeding a DCGL. These are generally secondary systems with very low probabilities of significant cross contamination due to the volumes of the systems and potential decrees of cross contamination, such as Fire Protection, Primary Water, Demineralized Water, Station Air, Instrument Air, etc.
: 4. CALCULATIONS 4.1. Containment Penetrations and Embedded Piping As noted in TSD 13-005 (1) and TSD 13-006 (2) the current plan is to remove all concrete inside the liners of the containment except for the incore sump area and access tunnel. This will minimize the amount of embedded piping remaining in the end state such that penetrations will make up the bulk of the surface area.
Unit 1 and Unit 2 containment penetrations are provided in drawings Unit 1 M-281, M-282 and Unit 2 M-661, M-662. As seen in Attachments A and B, the penetrations are located in three areas in the containment walls, the east and west Main Steam Tunnels and the Unit 1 north and Unit 2 south penetrations into the Auxiliary Building pipe chases as seen in Figure 1. Current plans are to remove piping from these penetrations leaving only the sleeves.
Figure 1 - Overall Layout of Containment Penetrations The penetrations and through wall piping are identical in both Unit 1 and Unit 2. The penetrations and the length and diameters of the penetrations with and without the piping (i.e., Open Sleeve) are provided in Attachment F and G.
There are also penetrations where the pipe will remain in the penetration (Pipe in Sleeve). As seen in Figure 1, each containment also has a penetration for the fuel transfer tube connecting the lower Page 8 of 123
TSD 14-016 Revision 0 cavity to the Fuel Handling Building Transfer Canal. Current plans are to leave the piping in place for these penetrations. The ends in the Containment up ender pit have blank flanges welded on as part of the cavity isolation preparations for internal segmentation. Since the end state requires all metals other than those embedded in concrete to me removed (3), it is anticipated that the pipes will be cut flush with the walls and open in the end state.
The length of the transfer tube piping in each unit is shown as 8 2.5 (e.g., 98.5 inches) in drawing B-213 Detail 4. With 24 inch OD and a 0.688 inch wall thickness the pipe ID is 22.624 inches. The void space volume is 39,597 cubic inches or 22.92 cubic feet (0.65 m3). The surface area is 48.62 ft2 or 4.52 m2.
Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4 As seen in Figure 3, there are also three Recirculating Sump Suction lines and two Cavity Flood Sump Suction lines that connect to the Auxiliary Building. The pipes are planned to remain in their sleeves. All five pipes are 20 inch pipes with 24 inch sleeves embedded in the concrete below the liner at the 561.25 foot elevation. One Recirculation Sump line is a spare that is capped at the Auxiliary Building penetration. The estimated lengths are approximately 50 feet as seen in Figure 3. The wall thickness of the 20 inch pipe is 0.594 inches making the inside diameter 18.812 inches. Although each pipe varies slightly in length the interior surface area is approximately 252 ft2 (23.41 m2) and 98.7 ft3 (2.80 m3).
Page 9 of 123
TSD 14-016 Revision 0 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping Each Unit 1 Cavity Flood Sump and Recirculation Sump pipes estimated length, surface area, and void space volume is provided in Table 1. The corresponding Unit 2 penetrations in Attachment F are P323, P324, P235, P236, and P237. The horizontal runs under the Containment 565 liner floor level are at the 5613 elevation making the top of the 24 inch diameter pipes at the 5623 elevation which is 29 below the end state liner floor level.
Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space Void Pipe                                  Interior Space                  Void OD      Wall      Pipe ID  Length Surface Volume          Int SA    Space Pen No.            Description              inches    Thkns      inches    Feet    Area ft2    ft3        m2        m3 P123      Recirculating Sump Suction          20      0.594      18.812    52.00    256.10    100.37      23.79      2.84 P124      Recirculating Sump Suction          20      0.594      18.812    52.83    260.20    101.98      24.17      2.89 P035      Recirculating Sump Suction          20      0.594      18.812    51.17    251.99    98.76      23.41      2.80 P036      Cavity Flood Sump Suction          20      0.594      18.812    50.75    249.94    97.96      23.22      2.77 P037      Cavity Flood Sump Suction          20      0.594      18.812    50.83    250.35    98.12      23.26      2.78 All of the other penetrations below the 588 elevation are assumed to have piping cut on either side of the penetration such that the length corresponds to the wall thickness and void space volume and interior surface areas correspond to the diameter as listed in Attachment F. The total estimated pipe lengths, surface areas and void space volumes in meters are provide in Table 2. The inventory associated with the Unit 1 and Unit 2 Containments are provided in Attachment G.
Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes Sum of                Sum of Unit 1 Category, End      Length Sum of      Void Space State            meters Int SA m2        m3 Bld to Bld Pen              169.20    242.36        32.48 Open Sleeve                88.19    119.99        17.75 Pipe in Sleeve            81.01    122.37        14.73 Page 10 of 123
TSD 14-016 Revision 0 Grand Total                169.20      242.36      32.48 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes Sum of                      Sum of Unit 2 Category,        Length      Sum of Int    Void Space End State            meters          SA m2          m3 Bld to Bld Pen            169.20        242.36        32.48 Open Sleeve              88.19        119.99        17.75 Pipe in Sleeve            81.01        122.37        14.73 Grand Total                169.20        242.36        32.48 4.2. Containment Incore Area Embedded Piping There is also a 1 1/2 pipe embedded in the concrete of the Incore Access Tunnel P125 for Unit 1 and P325 for Unit 2 on Attachment F. The incore area extends below the containment slab and consists of a cylindrical area directly under the reactor vessel biological shield and a sloped tunnel. The incore area walls are 1 foot 11.5 inches thick (23.5 inches) with a 2 foot 6 inches under vessel area floor. There is also an access tunnel with 15 inch thick walls, floor and roof. The sump is shown on drawing B-234 as being 2x 2x 2 at about 1 from the from the bend line. The pipe enters the wall about a floor above the sump making the opposite of the triangle 17+9-36 or 226 as seen in Figure 4. The base is 433 - 309 or 126 making the hypotenuse length 25.74 assuming the pipe enters the wall for about a foot before sloping up results in an estimated length of 26.74.
Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)
The estimated length, surface area, and void space volume in meters is provided in Table 4. The inventory of the incore pies is provided at the end of Attachment G.
Page 11 of 123
TSD 14-016 Revision 0 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume Sum of Length        Sum of Int SA      Sum of Void Space Row Labels                meters                  m2                    m3 Bld Pen                          8.15                1.05                  0.01 Embedded Pipe                  8.15                1.05                  0.01 Grand Total                      8.15                1.05                  0.01 4.3. Main Steam and Tendon Tunnel Aerated Drain Piping The tendon access tunnel galleries also contains a sump that has trace levels of contamination in sump water and sludge samples as well as trace levels of removable contamination. The Main Steam Tunnel floor drains also drain to this sump. There are 4 Aerated drains embedded in the tendon gallery access tunnel and Main Steam Tunnel floors. The Tendon Tunnel runs under the periphery of the Containment as shown in Figure 5 and has a floor elevation of 565-9-76 or 5486.As seen in Attachment D and Attachment E excerpted from drawings B-466, B-477, B-484, and B-487 the Main Steam Tunnel and Tendon Tunnel aerated drains are connected and drain to a common sump in the tendon tunnel. The Unit 1 drawings are shown on B-466 and B-467. The Unit 2 pipes are shown on B-481 and B-487. All of the pipes have a 4.5 inch outer diameter and 4.026 inch inner diameter. The penetrations are comprised of floor drains and clean out ports in the Mains Steam Tunnel that connect to a common header pipe. Attachment D shows M1 is a drain at 5696 1/2 to a bend beneath the floor. As seen on B-484 M1 drops to the 569 which is 0.54 feet. The pipe then makes a 45 degree run to the main drain line. As seen on B-466 the clean out port is 84 -2 thick wall or 64 from the wall. The 45 degree section is thus the hypotenuse of a 64 45 degree triangle or 8.96 feet. At Cleanout port M2 the pipe makes a 45 degree bend from the 569 to the 5687 or a 5 x 5 45 degree triangle which is 0.59 feet. The length of the run at 569 elevation between the 45 degree section is 48-64-5-6 from the wall or 353. As seen in Table 5. The Unit 2 drain M201 has slightly different lengths due to different elevations.
Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2 Pipe Section                M1              M201 Vertical                            0.54              0.69 45 Degree Bend                      8.96              8.96 45 Degree at Cleanout              0.59              0.62 Section between 45s                35.25              35.23 Total Length                      45.34              45.49 Penetration M2 is a 4 cleanout port that has a vertical section from the 56911 floor of the tunnel to the 5673 or 28 where it runs under the floor in a concrete encasement as shown on drawing B-466. It then run 38 from M2 to M3 resulting in a distance of 408 as seen in Table 6. The Unit 2 drain M202 has slightly different lengths due to different elevations.
Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3 Pipe Section                M2              M202 Vertical                            2.67              1.50 Section to M3, M203                38.00              38.00 Total Length                      40.67              39.50 The M3 vertical is the same as M1. There is a 45 degree bend from 56811 to 5673 or 18 at M3. This creates a 2.36 length. The length from the drain to the 45 degree angle is 6-18 or 44. The distance from Page 12 of 123
TSD 14-016 Revision 0 M3 to M4 at the 5673 elevation is 75-19+30 or 86 resulting in a total length of 93.23 feet as seen in Table 7. The Unit 2 drain M203 has slightly different lengths due to different elevations.
Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4 Pipe Section                M3                M203 Vertical                            0.54              0.67 Drain to Section to 45              4.33              5.54 45 Degree Bend                      2.36              0.65 Section to M4                        86                86 Total Length                        93.23              92.86 The vertical at M4 is the same as M1 and M3 at 6 1/2 or 0.54 feet. There is a 45 degree bend from the 56810 to the 5673 elevation or 17. The hypotenuse of the 17 45 degree triangle is 2.24 feet. The distance to the 45 degree bend is 6-17 or 45 which is 4.42 feet. There is a 45 degree bend from 5673 to 5662 or 11 near cleanout M5. There is a 45 degree bend at M5 from 5673 to the 5662 elevation or 11 which equals a 1.53 foot hypotenuse. The distance of the run at the 5673 from M4 to M5 is 92-30+26-11-10 for 76.92 resulting in 84.11 feet overall length from M4 to M5 as seen in Table 8. The Unit 2 drain M204 has slightly different lengths due to different elevations.
Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5 Pipe Section                M4                M204 Vertical                            0.54              0.71 Section drain to 45                  4.42              5.54 45 Degree Bend                      2.24              0.65 Section to 45 degree at M5          76.92              75.96 45 bend at M5                        1.53              2.89 Total Length                        84.11              82.86 M5 is a clean out at G34 that has a vertical section from 56911 to 5662 or 39. The length of the 5662 pipe from M5 to M7 can be interpolated at 306 feet based on the 24 dimension between columns 33 and 34 on B-466. This provides and overall length from M5 to M7 of 343 feet as seen in Table 9. The Unit 2 drain M205 has slightly different lengths due to different elevations.
Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7 Pipe Section                M5                M205 Vertical                            3.75              3.54 Section to M7                      30.50              30.50 Total Length                        34.25              34.04 M6 has a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5662 elevation for a 210 base resulting in a 4.01 hypotenuse. The distance from the drain to the wall is 10 feet leaving a 72 foot section from the drain to the 45 degree bend. This results in a 11.72 foot overall length as seen in Table 10. The Unit 2 drain M206 has slightly different lengths due to different elevations.
Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe Pipe Section                M6                M206 Vertical                            0.54              0.67 Section drain to 45                  7.17              6.80 Page 13 of 123
TSD 14-016 Revision 0 45 Degree Bend                      4.01              4.48 Total Length                        11.72              11.95 M7 is a clean out with a vertical from the 56911 1/2 floor to 5661 or 310 1/2. The clean out connects to a main pipe segment that goes to the Tendon Tunnel Sump. Drawing B-481 is more legible showing the cleanout to the bend is 26-13+58 or 188 for Unit 2. B-481 shows the length of the bend to the vertical to be 22 7 1/2 or 22.625 feet. The vertical drop from 5658 to the Tendon Tunnel Sump at 5436 is 222 equaling a total length from M-7 to the sumo of 674 as seen in Table 11. The Unit 2 drain M207 has slightly different lengths due to different elevations.
Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump Pipe Section              M7 to M8        M207 to M208 Vertical                            3.88              3.85 Section to bend                    18.67              18.67 Bend to Vertical at M8            22.625            22.625 Vertical M8 to Sump                22.17              21.67 Total Length                        67.33              66.81 M9 is similar to the other drains with a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5687 elevation for 5 base resulting in a hypotenuse or a 5 x 5 45 degree triangle which is 0.59 feet. As seen on B-482 for the Unit 2 equivalent section the distance from M9 to the main pipe from M-10 to M-7 is 26 feet from match line J to L minus 49 from L to the wall interior and minus 13 from J to cleanout M-10. Thus, the length from the drain to the 45 degree bend is 26-49-13-5 or 710. As seen in Table 12, the total length is 8.96 feet. The Unit 2 drain M209 has slightly different lengths due to different elevations. The Unit 2 drain M209 has slightly different lengths due to different elevations.
Table 12 - Main Steam Tunnel Drain M9 Center Pipe Pipe Section                M9                M209 Vertical                            0.54              0.67 Section drain to 45                  7.83              8.18 45 Degree Bend                      0.59              0.10 Total Length                        8.96                8.95 Cleanout port at M10 has a vertical from 56911 1/2 to 5689 1/2 or 1.17 feet. The equivalent section on B-481 shows a length of 193+226 or 419 from M10 to M7. The line drops 2.5 inches over this length but this does not add significantly to the length. The pipe the has a vertical drop from 5687 to 5661 or 26 to join the line from M7 to M8. This results in a total length from M10 to M7 of 45.42 feet. The Unit 2 drain M210 has slightly different lengths due to different elevations. The Unit 2 drain M210 has slightly different lengths due to different elevations.
Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7 Pipe Section                M10 to M7        M210 to M207 Vertical                                    1.17              1.16 Section to bend                            41.75              41.81 Bend to Vertical at M7 to 566'1"            2.5                0.5 Total Length                              45.42              43.47 M11 is similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M11 to center pipe can be interpolated at 165 feet based on the 24 dimension between columns 33 and 34 Page 14 of 123
TSD 14-016 Revision 0 on B-466. The length from the drain to the pipe is 6.96 feet as seen in Table 14. The Unit 2 drain M211 has slightly different lengths due to different elevations.
Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths Pipe Section                M11                M211 Vertical                            0.54              0.60 Section drain to main pipe        16.42              16.42 Total Length                      16.96              17.02 M12 is also a drain similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M12 to center pipe is 21-14-165 or 33. The length to M10 from M12 is shown on the Unit 2 equivalent section of B-481 at 14+13 or 27. The total length is 20.79 feet as seen in Table 15. The Unit 2 drain M211 has slightly different lengths due to different elevations.
Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10 Pipe Section                M12                M12 Vertical                            0.54              0.60 Section drain to main pipe          3.25              3.25 M12 to M10                        27.00              27.00 Total Length                      30.79              30.85 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210 As seen in Figure 5, the Tendon Tunnel floor is at 5486 elevation. The walls and floors are 2 thick making the interior floor width 46. There are drains from the Tendon Tunnel Buttress Pits that connect drain header in the Tendon Tunnel. The Buttress Pits are divided in to two sections by a wall in the center. A drainage system consisting of a through wall drain that allows accumulated water in one chamber to drain into the adjacent chamber and then through a floor drain down to the tendon tunnel floor drain header connected to the tendon tunnel east sump. As seen in Figure 7, there are 5 Unit 1 drains M13 thru M17 and 5 Unit 2 M213 thru M217 from the Tendon Buttress Pits at the 564 11 1/2 that drop 13 1/2 to the 5638 where they run horizontally about 36 into the center of the 2 thick wall. The lines then run vertically to the 5479 which 9 below the Tendon Tunnel Floor slab. They then run horizontally on a 45 degree angle to join the drain Page 15 of 123
TSD 14-016 Revision 0 pipes at the center of the tunnel. The tunnel is 46 wide making it 23 from the wall interior to the pipe.
The wall is 2 feet thick making the length to wall 1 foot making the base of the 45 degree pipe 33 which results in a total length of 4.6. This is a total length of 30.3 feet for each of the 5 pipes for a total of 151.52 feet per Unit as seen in Table 16.
Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217 Pipe Section                    M13 - M17      M213 - M217 Vertical to Horizontal                                1.29            1.29 Horizontal into Tendon Tunnel Wall                    3.5              3.5 Vertical to Tunnel                                  20.92            20.92 Horizontal to Center Pipe                            4.60            4.60 Total Individual Length                              30.30            30.30 Total M13 - M17 Length                              151.52          151.52 As seen in Figure 7, the Tendon Tunnel drains are embedded approximately 7 inches in the floor at the 54611 elevation. The drains M18 through M23 and M18 through M223 have a vertical section from 548 6 1/2to 54711 or 7 1/2. The total length of these vertical section in Unit 1 and Unit 2 is 39.
Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths Unit 1                Unit 2 Pen      Length ft      Pen      Length ft M018        0.625      M218        0.625 M019        0.625      M219        0.625 M020        0.625      M220        0.625 M021        0.625      M221        0.625 M022        0.625      M222        0.625 M023        0.625      M223        0.625 Total        3.75                  3.75 Drawing B-210 shows that the tunnels are 46 wide with 2 thick walls. B-481 shows that M18 is at the 368 degree mark and M23 is at the 68 degree mark. B-481 shows M223 is at the 68 degree mark and M218 is at 368 degrees. As seen in Table 18, the pipe is 83% of a circle.
Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle Unit 1                                      Unit 2 Start          End          Total          Start          End        Total Degree        Degree      Degrees        Degree        Degree      Degrees 68            0              68            68            0            68 360          368            -8          360            368            -8 Total          60                                        60 Pipe Percent Circle          83%                                        83%
As seen in Figure 6, it is 666 to the interior wall, with the pipe in the center that would add 23 making the pipe radius 689. This is also shown on drawing B-466 and B-481 as seen in Figure 7.
Page 16 of 123
TSD 14-016 Revision 0 Figure 6 - Tendon Access Gallery Details (B-210)
Page 17 of 123
TSD 14-016 Revision 0 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466 M24 and M244 are the circular portion of the embedded pipe. The 689 radius multiplied by 2 Pi and 0.83 for the percentage of the circle results in a 359.97 length. The pipe from M25 to the sump is 23 to the wall then 76 to the sump or 99.
A summary of the Unit 1 and Unit 2 Main Steam drains estimated lengths, surface areas and void space volumes in meters are provide in Table 19. Table 20 has the summary for the Buttress Pit and Tendon Tunnel drains. The list of penetrations and pipes is provided in Attachment H.
Page 18 of 123
TSD 14-016 Revision 0 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Sum of Length        Sum of Int SA      Sum of Void Space Category and End State              meters                m2                    m3 U1 Aerated Drain                      145.93              46.88                1.20 U1 Bld Pen                          145.93              46.88                1.20 Embedded Pipe                    145.93              46.88                1.20 U2 Aerated Drain                      144.41              46.39                1.19 U2 Bld Pen                          144.41              46.39                1.19 Embedded Pipe                    144.41              46.39                1.19 Grand Total                          290.34              93.28                2.38 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Sum of Length        Sum of Int SA      Sum of Void Space Category and End State                meters                m2                    m3 U1 Bld Pen                            160.02              51.41                1.31 Embedded Pipe                      160.02              51.41                1.31 U2 Bld Pen                            160.02              51.41                1.31 Embedded Pipe                      160.02              51.41                1.31 Grand Total                          320.04              102.82                2.63 Page 19 of 123
TSD 14-016 Revision 0 4.4. Auxiliary Building Penetrations and Embedded Piping Auxiliary Building penetrations are provided in drawings M-281, M-282 for Unit 1 and M-661, M-662 for Unit 2. The penetrations to the Spent Fuel Building are located at R17 and R23 as seen in Attachments A and B. Drawing M-107 Sheet 1 Section A-A and B-B show the end view of the penetrations in the Auxiliary Building as seen in Figure 8. Note that Unit 1 penetration A29 is unlabeled on M-107 Sheet 1. There is also an unlabeled penetration on M-107 Sheet 2 next to the A43 penetration of OFP-016-4 on M-107 Sheet 2 at Column 22 between match line X and U. However, this line is labeled on the drawing as 1SF-017-2 next to the OFP-016-4 at column 24 match line S.
Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23.
Page 20 of 123
TSD 14-016 Revision 0 M-107 Sheet 2 shows most of the pipes paralleling the Spent Fuel Building foundations then rising vertically to above the 583 elevation after passing under the Fuel Transfer Canal. The exceptions being those pipes with boxes around them in Figure 8. These are a 2 inch diameter oil line A42 ODO-100-2 that remains near the 573 elevation and a 4 inch vent line A40 1AD-046-4 that only rises to the 579 elevation. These lines routes are traced in red in Figure 9. The Unit 1 and 2 24 diameter Safety Injection lines A36 and A51 also do not rise above the 573 elevation.
Figure 9 - M-107 Sh2 Excerpt Top View Enlarged Plan A and Plan B of M-107 Sheet 1 show the top view and piping lengths as the parallel the Containments and pass under the Spent Fuel Transfer Canal as seen in Figure 12. B-118 shows the side view of the Unit 1 piping relative to the foundation and clearly indicates as seen in the red circled notations noted in excerpt provided as Figure 10. The Unit 2 side view from B-120 has similar notations indicating the piping is encased in concrete as seen in Figure 11.
Page 21 of 123
TSD 14-016 Revision 0 Figure 10 - Side View Unit 1 Excerpt from B118 Figure 11 - Side View Unit 2 Excerpt from B-120 Page 22 of 123
TSD 14-016 Revision 0 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107 Drawing M-106 Sections K-K and K1-K1 show the side view of the piping passing through the walls of the Auxiliary Building, Under the Spent Fuel Transfer Canal and out through the Spent Fuel Building Walls as seen in Figure 13.
Page 23 of 123
TSD 14-016 Revision 0 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106 As seen in Figure 8, Figure 9, Figure 10, and Figure 11 both Unit 1 and Unit 2 penetrations to the Spent Fuel Building have a 24 inch Safety Injection line 1SI-012-24 and 2SI-012-24 A36 and A51 that run from match line R to match line X. As seen in Figure 9 the lines were installed for a future Safety Injection tank that was never installed. Consequently, the lines are capped on both ends and were never used.
Page 24 of 123
TSD 14-016 Revision 0 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions As seen in Figure 14, the distance to the bend is 6 for the cap plus 39 and 159 as seen on M-107 Sheet 2 which is 20 feet. M-105 SH2 also shows the 45 degree bends is 310 the hypotenuse of which is 5.421 feet.
As seen in Figure 13, the centerline elevation at R is 568 plus 2 or 570. This makes the remaining distance to match line S 25-159-310 or 55. There is also an elevation change at the bend from 570 inches to Page 25 of 123
TSD 14-016 Revision 0 573 feet increasing the length of the bend by the square root of 5.421^2 + 3^2 to a length of 6.2 feet. The distance from match line S to the end cap past X is 25+126 plus 1 to the end cap or 386 for a total length of 70.11 feet.
Table 21 - 24" Safety Injection Pipe Segments A36 and A51 Section                Length feet End Cap at R                        0.5 Length to elbow                    19.5 Bend                                6.20 Remaining to S                      5.42 Remaining to End Cap                38.50 Total                              70.11 As seen on Figure 8, each unit also has two 10 diameter component cooling lines A49 1CC-078-10, A50 1CC-080-10, A59 2CC-078-10, A60 2CC-080-10. They are at the 5707 at match line R. As seen in Figure 13, the pipes run horizontally from R to where they make a vertical rise to the 584 elevation. The length is 1+29+133+9+9 or 186. The pipes then rise vertically from 5707 to the 584 elevation or 135. For Unit 1 the pipes then run parallel to the SFB past match line X where they pass through the wall.
Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2 The distance from vertical to match line S is 25-149 or 103, the then proceeds 25 to X. Past X they turn North through the wall at A49 64 for 417 length and A50 710 for a 431 length.
Page 26 of 123
TSD 14-016 Revision 0 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall As seen in Figure 8, A49 is 39+110 from Column 23 or 57 and A50 is an additional 14 from column 23 or 611. It is 26 from column 23 to column 21 and 176 to column 20. The Unit 1 penetrations through the 592 floor are 16 beyond that making the total from column 23 45 feet. A 4 foot long vertical section will remain from the 584 to the 588 elevation. The calculated pipe segment lengths and the overall lengths are summarized in Table 22.
Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths A49 Unit 1 Length      A50 Unit 1 Section                                feet            Length feet Length R to Vertical to 584'                                  18.5                18.5 Length of Vertical 570'7" to 584'                            13.42                13.42 Length from Vertical to SFB Wall Penetrations                41.58                43.08 Distance North to Col 23                                      5.58                6.92 Distance Col 23 to Vertical                                  45.00                45.00 Vertical Toward Slab                                            4                  4 Total                                                        128.08              130.92 Page 27 of 123
TSD 14-016 Revision 0 The Unit 2 10 Component Cooling lines A59 2CC-078-10 and A60 2CC-080-10 paths are also shown in Figure 15. The distance to the 584 vertical and to vertical lengths are the same as Unit 1 186 and 135.
The distance to S is 25-14-9 or 113. The distance to from X to the bend of A59 2CC-078-10 is noted as 3+39 or 69. There is an additional 6 feet from the notation of 8 pieces at 8 inches. The distance from S to the bend is the 25 from S to X minus 129 or 123. The total length of A59 2CC-078-10 from the vertical to 584 elevation is 236. The length of A60 2CC-080-10 is 26 closer to S or 21. For the southward segment between S & X as seen in Figure 15, the distance from column 17 is the distance from column 19 to 17 26-149 or 113 inches. As seen in Figure 8, the distance from column 17 to A59 2CC-078-10 is 39+110 or 57. A 60 2CC-080-10 is an additional 14 further or 611. The length of A59 to the bend north is 113+57 or 1610. The length of A60 is 113+611 or 182. The segment west past match line X for A59 2CC-078-10 is 26+3+39 to X with an additional 64 past X or 157. The distance west for A60 is 3+39+64+16 or 147. The distance south again to the vertical from 584 to the floor penetrations on 593 is 149+2 for both pipes as seen on Figure 15. A 4 long part of the vertical from 584 to 588 elevation will also remain. The lengths of each segment and totals lengths are provided in Table 23.
Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths A59 Unit 1 Length      A60 Unit 1 Section                              feet            Length feet Length R to Vertical to 584'                            18.5                18.5 Length of Vertical 570'7" to 584'                      13.42                13.42 Vertical to Bend South                                  23.5                  21 South to Bend West                                    16.83                18.17 West to Bend South Past X                              15.58                14.58 South to Vertical to Pens                              16.75                16.75 Vertical to 588                                        4.00                4.00 Total                                                108.58              106.42 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 4 inch drain line A40 1AD-046-4 at the 5694 elevation at match line R. As seen in Figure 14 the 4 line A40 1AD-046-4 runs horizontally from R to where it makes a vertical rise to the 5799 elevation. The length to the vertical bend is 1+29+133+9+9 or 186. The pipe then rises vertically from 5694 to the 5799 elevation or 105.
The 4 drain pipe then runs west parallel to the SFB past match line X sloping up to the 5808 elevation before going through the wall of the Spent Fuel Building. It is 103 from the vertical to match line S. It is 25 from S to X and the line makes its bend 3 feet past X for a total length of 383. It rises 11 providing a hypotenuse of 38.26 feet.
Page 28 of 123
TSD 14-016 Revision 0 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2 As seen in Figure 8, A40 is 39+14+1+16+9+9 or 91 from Column 23. It is 26 feet to column 21 and the pipe extends another 176 - 123 or 53 for a total length of 91 + 26+ 53 or 404. The pipe also rises a foot to the 5818 making the hypotenuse length 40.35 feet. The pipe then runs west again 11 feet and rises from 5818 to 582 but the slight change does not affect the length. The pipes then rise vertically from the 582 to the 588 elevation for a 6 foot vertical segment. The segment lengths and total lengths are provided in Table 24.
Table 24 -A40 Unit 1 4" Drain Line Segment Lengths A40 Unit 1 Length Section                            feet Length R to Vertical to 584'                            18.5 Length of Vertical 569'9" to 579'9"                    10.42 Length from Vertical to SFB Wall Penetrations          38.26 Distance North to Bend West                            40.35 West to Vertical through Slab                          11.00 Vertical to 588' at Floor Pen                          6.00 Page 29 of 123
TSD 14-016 Revision 0 Total                                                    124.52 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 2 inch oil line A42 ODO-100-2 that remains near the 573 elevation. The 2 inch oil line is at the 5694 at match line R. As seen in Figure 13 the pipe runs horizontally from R to where it makes a vertical rise to the 5722 elevation near the 45 degree bend in the SI pipe. Figure 13 and Figure 17 show the length is 1+39+159 or 206. Along this length, the pipe slopes upward from 5684 to 5688 but this does not significantly affect the length. The vertical rise is 5722-5698 or 26. From the 26 vertical it continues west the length to match line S is 25-159 to X 25 to 49-3 or 19 past X for a total length of 36 feet. As seen on Figure 17 the pipe slopes upward from 5722 to 5736 over the length past X for a 14 rise which results in a length of 36.02 feet. The line then continues south toward the tank and slopes vertically from the 5736 elevation to the 576 elevation or 26 over the length which is 151-65 or 88 to the center of the tank. With the 26 rise this is 9.02 to the center of the tank. Assuming the pipe from the wall to the tank is removed during the excavation and removal of the tank this is a length of about 46 feet.
Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths A42 Unit 2 Length Section                              feet Length R to 4" Vertical to 569'8"                      20.50 Vertical to 572'2"                                      2.50 Vert to 572'2" West to Vertical Past X                36.02 Vertical to 576'                                        4.52 Total                                                  63.55 Each Unit has three 1.5 Tell Tale drain lines as seen Figure 8. The penetration and line identifications are A38 1AD-148-1 1/2, A39 1AD-147-1 1/2, A37 1AD-149-1 1/2 for Unit 1 and A53 2AD-148-1 1/2, A54 2AD-147-1 1/2, A52 2AD-149-1 1/2. As seen in Figure 8, these lines are at the 571 elevation at match line R. As seen on M-107 Sheet 2 and the excerpt provided as Figure 18, one of the drain lines in each unit goes vertically into the transfer canal wall between the pool and the canal. The other two go vertically toward the 584 elevation penetrations at the 186 bend.
Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2 M-106 Section K-K, K1-K1 shows the two Tell Tale drain lines extending vertically without bending to process west with the other pipes.
Page 30 of 123
TSD 14-016 Revision 0 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines As seen on the Unit 2 side of M-107 SH2, the first drain A54 2AD-147-1 1/2, and A39 1AD-147-1 1/2 elbow into the Fuel Transfer canal concrete is 39+53 to the wall or 9 feet. The 1 foot dimension from the drawing transposed on the wall shows the drain line bends south it at 10 feet. The distance south is 29. The vertical section is assumed to be the 5 feet minimum distance to the bottom of the transfer canal at 576. The line segment lengths are summarized in Table 26.
Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths A39, A54 AD-147-1 Section                          1/2 feet Length to Bend South                                    10 Length South to Vertical                              2.75 Vertical to 576'                                        5 Total                                                17.75 The other four Tell Tale lines are shown in Figure 19. The distance to the vertical bend is 1+29+133+9 or 179. M-106 Section K-K shows the lines continuing vertically past the 584 elevation for a minimum length of 13. The lengths beyond that are undetermined. The lengths for the segments identified are summarized in Table 27.
Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths A38, A53 AD-148-1        A37, A52 AD-Section                            1/2 feet          149-1 1/2 feet Length to Bend South                                  17.75              17.75 Vertical to 584'                                        13                  13 Total                                                  30.75              30.75 Each Unit has 1 1/2 station air lines as well A41 1SA-014-1 1/2 and A66 2SA-012-1 1/2. As seen on Figure 8 they are at the 5694 elevation. Their layout is highlighted on the M-107 SH2 overhead vie in Page 31 of 123
TSD 14-016 Revision 0 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout The Unit 1 line 1SA-014-1 1/2 goes vertical to vertical bend that leads to the 583 elevation. The length to the vertical segment is 1+29+14+9 or 186. The vertical segment is from the 5694 to the 583 or 138. The distance of the segment at 583 elevation to S is 103 and 25 to X and 3+16+45+4(9) or 1111 for a total length of 472. The line travels north to the penetration with a length of 39+14+1+16+9 or 84 to Column 23 as seen in Figure 8. The penetration is 16 past column 23 for a total length of 910.
Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths A41 1SA-014-1 1/2 Section                        Length Feet Length to Bend South                                    18.5 Vertical to 583'                                        13.67 West to SFB                                            47.17 North to Pen                                            9.83 Vertical to 588                                          5 Total                                                  94.17 Page 32 of 123
TSD 14-016 Revision 0 The Unit 1 Service Water line is a 2-inch diameter line and with a layout parallel to the Unit 1 Station Airline 1SA-012-1 1/2 in Table 28. The Unit 1 Station Air line A44 1SA-014-1 1/2 is shown on Figure 20. The Service Water line travels the same 186 distance to the vertical. The exceptions are that the elevation at R is 5707 and the vertical rise is also to the 584 elevation making that segment 135. The length to the bend into the building is 18 shorter than the station air line at 458 versus 472. The distance north to the penetration in the floor is the slightly greater because the penetration is further from column 23 at 39+110+14+11+9+9 or 9/6 to Column 23 versus 84 for the Station Air. The penetration is 16 past column 23 for a total length of 11. same but the remaining height of the vertical segment is 4 feet rather than 5 feet since the elevation is 584 versus 583.
Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths A44 1SW-181-2" Section                          Length Feet Length to Bend South                                      18.5 Vertical to 584'                                        13.42 West to SFB                                              45.67 North to Pen                                            11.00 Vertical to 588                                            4 Total                                                    92.58 The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 runs parallel to and between the Station Air A41 1SA-014-1 1/2 and the A44 Service Water line A44 1SW-181-2. The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 is shown on Figure 20. The Instrument Air line travels the same 186 distance to the vertical. The elevation at R is 5707 the same as the Service Water and the vertical rise is to the 584 elevation making that segment 135 as well. The length to the bend into the building is 9 longer than the service water line at 465 versus 458. The distance north to the penetration in the floor is the 8 further as seen in Figure 8 making the length 118. The remaining height of the vertical segment is the same at 4 feet since the 584 elevation is the same. The pipe section lengths are summarized in Table 30.
Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2" A46 OIA-004-1 1/2" Section                          Length Feet Length to Bend South                                      18.5 Vertical to 584'                                        13.42 West to SFB                                              46.42 North to Col 23                                          11.67 Vertical to 588                                            4 Total                                                    94.00 The Unit 1 A43 Fire Protection line OFP-016-4" penetration is next to and parallels the Service Water line A44 as seen Figure 8 and Figure 20. The distance to the bend vertically is 186 inches. The elevation is also 5707 at R and 584 at the vertical resulting in the same 135 vertical length. The segment west from the vertical to 584 is 9 shorter than the Service Water pipe or 4411. As seen in Figure 8 the distance from column 23 to the penetration is 9 less than the service water making the overall length north to the penetration 103 rather than 11. The remaining vertical to the penetration is also 4 feet. The pipe segment lengths are summarized in Table 31.
Page 33 of 123
TSD 14-016 Revision 0 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths A43 OFP-016-4" Section                          Length Feet Length to Bend South                                      18.5 Vertical to 584'                                        13.42 West to SFB                                              44.92 North to Pen                                            10.25 Vertical to 588                                            4 Total                                                    91.08 As seen in Figure 17, there is an unlabeled pentation next to the Fire Protection penetration on M-107 Sheet
: 2. As explained in the text above Figure 8, the line is identified at Column 24 match line S as 1SF-017-2 and labeled as Demin Water indicating it was a clean water supply to the spent fuel pool. As seen Figure 21 line changes designation from 1DW012-2 to 1SF17-2 at valve 1SF0004 on drawing M-63. The M-69 shows the DW system and the start of that line and references the M-63 drawing for continuation. The M-63 drawing references the M-69 drawing and shows the SF system along with the 1SF0004 valve and the beginning of the 1SF017-2 line.
Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply The label on M-107 SH 1 indicates the lines is at the 5834 1/2 elevation. The penetration elevation at R is 5707 resulting in a vertical of 129 1/2. The length to the vertical is the same at 186. The length west from the vertical to bend north is 9 shorter to the floor penetration than the Fire Protection line at 442. The penetration at R is 9 closer to column 23 than the Fire Protection line resulting in the north segment to the floor penetration being 96. The vertical segment toward the floor penetration is longer going from 583 4 1/2to the 588 or 4 7 1/2. The pipe segment lengths are summarized in Table 32.
Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths A29 1SF-017-2" Section                          Length Feet Length to Bend South                                      18.5 Vertical to 584'                                        12.79 West to SFB                                              44.17 North to Pen                                              9.50 Page 34 of 123
TSD 14-016 Revision 0 Vertical to 588                                        4.625 Total                                                  89.58 Several lines have penetration through the Fuel Handling Building floor east of 1SF-017-2 as seen on M-106 Sheet 2 and Figure 20. These lines are A48 1SF-008-2, A47 1SF-022-3, and A40 1AD-146-4. M-63 shows A48 1SF-008-2to be a Refueling Water Storage Tank line and A47 1SF-022-3 to be a Fuel Pool Demineralizer line indicating they are Class 1 lines. It is 186 to the vertical for both A48 1SF-008-2and A47 1SF-022-3. Both lines are at the 5694 elevation at match line R making the vertical length to 583 138 long. Both lines the travel west parallel to the Fuel Handling Building slab. The distance to match line S is again 25-149 or 103. It is 25 to X with an additional 39 for 1SF-022-3 and 46 for 1SF-008-2 past X to the bend north. The total length of the west segments from the vertical to the bend is 39 for 1SF-022-3 and 399 for 1SF-008-2. The distance of the penetrations at R from column 23 is shown in Figure 8 for 1SF-022-3 it is 39+14+1 or 61. 1SF-008-2 is 16 further south or 77. M-107 SH 2 shows the distance from column 23 south to floor penetrations in 16 for both pipes leading to lengths of 91 for 1SF-022-3 and 83 for 1SF-008-2 to the vertical segment through the slab. Each pipes vertical segment is from 583 to 588 or 5 feet. The line segment lengths are summarized in Table 33.
Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths A48 1SF-008-2        A47 1SF-022-3 Section                          Length Feet            Length Feet Length to Bend South                                    18.5                  18.5 Vertical to 583'                                        13.67                13.67 West to SFB                                            39.75                39.00 North to Pen                                            9.08                  8.25 Vertical to 588                                          5                    5 Total                                                  86.00                84.42 The Unit 2 Station Air line A66 2SA-012-1 1/2 is shown on Figure 20. It travels the same 186 distance to the vertical and has the same vertical length of 138 to the 583 elevation. Like the other lines, it bends south between S and X. The distance from vertical to match line S is 25-149 or 103. The distance to from X to the bend is noted as 3+39 or 69 with another 9 to the line for 76 which give a length from S to the bend of 25-76 or 176. The total length to the bend is 103+176 or 279. As seen on Figure 8 A66 is 39+310+9+9+9 from Column 17 or 910. It is 149 to the pipe from Column 19 with a 26 distance from columns 19 to 17 this is 113 this plus the 910 to column 17 is 211. From there it turns west again and parallels the foundation which extends to just past match line U. Piping past the foundation is assumed to be buried pipe that will be removed. It is 149 to X then 25 to U then 39 to the end of the foundation for a total length of .436 The remaining line past the foundation will be removed. The Unit 2 Station Air segment lengths are summarized in Table 34.
Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths A66 2SA-012-1 1/2 Section                          Length Feet Length to Vertical West                                  18.5 Vertical to 583'                                        13.67 Length West to Bend South                              27.75 South from Bend Past S to Bend West.                    21.08 Length West to End of Foundation                        43.5 Total                                                  124.5 Page 35 of 123
TSD 14-016 Revision 0 Each Unit has Service Water supply lines A65 2SW-243-3 parallels the Unit 2 Station Air line A66 2SA-012-1 1/2 in Table 28. The exceptions are that the elevation at R is 5707 and the vertical rise is to the 584 elevation making that segment 135. The distance west to the bend from the vertical is 9 further at 286.
The distance of the penetration from column 17 is 39+110+14+11+9+9+9 or 103 instead of 910 for A66 making the length of the segment south from the bend 216. The length west to the end of the foundation is 9 shorter or 429. The segment lengths are summarized in Table 35.
Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths A65 2SW-243-3" Section                          Length Feet Length to Vertical West                                  18.5 Vertical to 584'                                        13.42 Length West to Bend South                                28.5 South from Bend Past S to Bend West.                    21.50 Length West to End of Foundation                        42.75 Total                                                  124.67 The Unit 2 Aerated Drain line A62 2AD-146-4 parallels the path of the Service Water 2SW-243-3 over much of its length. It runs next to 2SA-012-1 1/2 whose segment lengths are shown in Table 34. The length to the vertical is 186. As seen in Figure 8, the penetration is at the 5707 Figure 20 shows the elevation of the vertical at 584 making the length 135. The pipe then runs west to where it bends north. The distance west is 9 less than 2SA-012-1 1/2 length or 27. The penetration at R is 39+110+14+11+9+9 or 96 to column 17. The additional length is 26-149 or 113 for a total length of 209 feet. It then proceeds west 69 to match line X and 25-26 or 226 for a total length of 293. The distance from the bend south to the penetration is 149+2 or 169. The vertical segment to 588 elevation is 4 feet. The pipe section lengths are summarized in Table 36.
Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths A62 2AD-146-4 Section                          Length Feet Length to Vertical West                                  18.5 Vertical to 584'                                        13.42 Length West to Bend South                                27 South from Bend Past S to Bend West.                    20.75 Length West After Bend                                  29.25 Length South                                            16.75 Vertical to 588'                                          4 Total                                                  129.67 As seen on Figure 8, there is no ODW-008-3 line at the Unit 2 penetrations at R. There is a 2DW-014-3 and a 2DW-008-3. There appears to be incorrect labeling of the lines on M-107 Sheet 2 as seen in Figure 22 since 2DW-014-3 and 2DW-008-3 cannot be the same line and have two different penetrations at R21 in Figure 8.
Page 36 of 123
TSD 14-016 Revision 0 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2 Therefore, the lines segment lengths will be assigned to the 2DW-014-3 and 2DW-008-3 as shown in Figure 22. Both lines run parallel to 2AD-146-4. Both are 186 to the vertical. 2DW-014-3 is at the 5707 elevation at match line R and 2DW-008-3 is at the 5694 elevation as shown on Figure 8. They are both assumed to be at the 583 elevation as indicated in Figure 13 which shows two 3 lines at K1-K1. This results in a vertical rise length of 125 for A63 2DW-014-3 and 138 for A61 2DW-008-3. The 2DW-008-3 segment west from the vertical rise to the bend south is 9 shorter than 2AD-146-4 at 263. 2DW-104-3 is an additional 9 shorter at 256. As seen in Figure 8, 2DW-014-3 is 9 closer to column 17 that 2AD-146-4 or 20 2DW-008-3 is 39+17+9+16+9+9 or 91 with an addition 26-149 from column 17 this makes the length 204. From the bends, south the lines turn west for a length where 2DW-014-3 is 9 shorter than 2AD-146-4 or 286. 2DW-008-3 is 9 shorter than 2DW-014-3 or 279. The length south to the vertical leading to the floor penetration is the same as 2AD-146-4 or 169. The vertical to the 588 foot elevation is 5 feet. The calculated line segment lengths are provided in Table 29.
Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths A63 2DW-014-3    A61 2DW-008-3 Section                        Length Feet      Length Feet Length to Vertical West                                  18.5              18.5 Vertical to 583'                                        12.42            13.67 Length West to Bend South                                25.5            26.25 South from Bend Past S to Bend West.                    20.00            20.33 Length West After Bend                                  28.5            27.75 Length South                                            16.75            16.75 Vertical to 588'                                          5                5 Total                                                  126.67            128.25 OCT-61-2 at penetration A58 parallels 2DW-014-3 for most of its length but appears to terminate outside the SFB wall. It is the line from the Decontamination Pad to the Chemical Drain Tank making it a MARSSIM Class 1 line.
Page 37 of 123
TSD 14-016 Revision 0 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination It is 186 to the vertical bend. As seen on Figure 8, A58 OCT-061-2 is at the 5694 at the match line R penetrations making the vertical to the 583 138. The westward run to the bend south is 9 shorter than 2DW-014-3 or 279 long. As seen in Figure 8 it is 9 closer to column 17 than 2DW-008-3 or 84 which makes the total length with 26-149 added a total of 197. The distance west to the termination of the line segment is 4 x 9 or 3 with an additional 3+3.75+3.5 as seen in Figure 23 for a total of 133. The calculated segment lengths are provided in Table 38.
Table 38 - A58 OCT-061-2" Line Segment Lengths A58 OCT-061-2 Section                      Length Feet Length to Vertical West                            18.5 Vertical to 583'                                  13.67 Length West to Bend South                          24.75 South from Bend Past S to Bend West.              19.58 Length West After Bend                            13.25 Total                                              89.75 Page 38 of 123
TSD 14-016 Revision 0 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path As seen in Figure 24, the Unit 2 Waste Discharge line A64 OWD-059-2 1/2 parallels OCT-061-2. As shown in Figure 8, the line is at the 5707 elevation at the penetrations at R17. The distance to the vertical bend is 186. The pipe rises from 5707 elevation to the 584 elevation or 135. The section west is 9 shorter than OCT-061-2 or 24. The penetration is 9 closer to column 17 than 2DW-014-3 or making the total length of the south running segment 193. The segment west to the second bend south is 5 x 9 or 39+3+39+14+3 or 276. It then travels west to the vertical bend to the penetration 149+176+123 or 446. The vertical to the 588 is 4 feet. The pipe section lengths are summarized in Table 39.
Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths A64 OWD-059-2 Section                        1/2 Length Feet Length to Vertical West                                  18.5 Vertical to 584'                                        13.42 Length West to Bend South                                24 South from Bend Past S to Bend West.                    19.25 Length West After Bend                                  44.5 Vertical to 588'                                          4 Total                                                  123.67 As seen in Figure 25, the remaining Unit 2 lines all run parallel to OWD-059-2 1/2 and terminate in the same area. A57 0SF-012-3", A55 2SF-008-2", A56 2SF-022-3".
Page 39 of 123
TSD 14-016 Revision 0 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout Figure 26 from excerpted from drawing M-63 shows that 0SF-012-3"feeds the Auxiliary Building Hold-Up Tanks (HUTs), 2SF-008-2" provides water to the Spent Fuel Pool supply and return from the Unit 2 Refueling Water Storage Tank, and 2SF-022-3" to the Unit 2 Spent Fuel Water Demin making all these lines Class 1 MARSSIM lines.
Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines Page 40 of 123
TSD 14-016 Revision 0 As seen in Figure 20, each line is 186 from the penetrations at R17 to the vertical bend. As seen in Figure 8, the penetrations are on the same elevation as OCT-061-2 and like OCT-061-2 rise to the 583 elevation or 138. 2SF-008-3 has a length west from the vertical that is 9 shorter than OCT-061-2 or 24. The west segment length from the vertical of 2SF-022-3 is 9 shorter than 2SF-008-2 at 233 and OSF-012-3 is 26 shorter than 2SF-008-2 or 209. As seen in Figure 8, A55 2SF-008-2 is 9 closer to column 17 than OCT-061-2 or 1810 when the 113 from column 17 is included. 2SF-022-3 is 16 closer to column 17 than 2SF-008-2 or 174. OSF-12-3 is 9 closer than 2SF-022-3 or 167. As seen in Figure 25, the lengths west after the first bend south for OSF-12-3 is 26 +6+3+39+3 or 183. 2SF-22-3 is 6+3+39+3+9 or 166 and 2SF-008-2 is 6-9+3+39+3+9+9 for 166 also. The length south to the vertical to the penetrations is the same length as 2CC-078-10 and 2CC-080-10 or 169 and the vertical from the 583 to 588 is 5. The pipes segment lengths are summarized in Table 40.
Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3" A55 2SF-008-2      A56 2SF-022-3      A57 0SF-012-3 Section                          Length Feet          Length Feet      Length Feet Length to Vertical West                                  18.5                18.5              18.5 Vertical to 583'                                        13.67                13.67              13.67 Length West to Bend South                                  24                23.25              20.75 South from Bend Past S to Bend West.                    18.83                17.33              16.58 Length West After Bend                                    16.5                16.5              18.25 Length South to Floor Pen Vertical                      16.75                16.75              16.75 Vertical to 588'                                            5                  5                  5 Total                                                  113.25                111              109.5 The Containment to Auxiliary Building pipe chase penetration shown in Figure 1 are already attributed to the Containments whose walls form the interior wall of the Auxiliary Building Pipe Chase as well. The Containment Sump piping at M-16 and M-24 in Figure 3 are also attributed to the Containment. The next penetration is a 14 inch sleeve through the 2 foot thick wall between the Aux Building and a Main Steam Tunnel at the 571 elevation as seen on Attachment B near row H column 10. There is a similar sleeve on the opposite wall at H30. As seen on Attachment B, there is a 10 inch Fire Protection Line OFP-12-10 at H10 that is shown on Drawing M-165 and M-187. Near G10 there are two OSW-008-12 lines as seen on drawing M-185 and Attachments A & B.
As seen on Attachment A and B there are many penetrations along the wall at Row G between the Turbine Building and Auxiliary Building. All penetrations labeled as open sleeve are assumed to have the pipe removed, leaving an opening equal to the outer diameter of the pipe. Attachment B shows penetrations at G13 consisting of a 3 waste disposal line OWD-31-3 from Drawing M-165 and M-171.
There are two 12 Service Water Supply lines to the Diesel Generator Heat Exchangers at J9 A27, A28 and J31 A30, A31as seen on Attachments A and B. As seen in Figure 27, these lines pass under the steam tunnels for 21 feet, then under the tunnel floor towards G for 143 and 1`23 plus the 219 of H to G. Detail C of M-106 (provided as Figure 28) shows an elevation change from 554 9 and 5534 at G to 567 6at J. This is an additional 142 and 129 making the total lengths of the lines 71 2 and 69 9 or 837 and 833 inches respectively. As seen in Figure 28, the horizontal runs under the Main Steam Tunnel are at 5636, the floor is at 570 so the pipes are 66 below the floor in the fill material below the slab. The horizontal run under the Diesel Generator floor are at the same elevation with the floor at the 5676. The pipes horizontal runs are 4 feet below the floor. Thus, none of the horizontal runs of A27, A28, A30, or A31 are with 8 of the surface of any floor.
Page 41 of 123
TSD 14-016 Revision 0 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106.
Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers Attachments A & B show the 48 in Service Water Supply penetrations C26 and C29. As seen on drawings M-168 and M-169 two 48 inch Service Water Supply Header pipes, OSW-13-48 (C29) and OSW-14-48 (C26), exit the Auxiliary Building at elevation 5498 at G19 and G21. As shown on Figure 39 excerpted from M-103 and M-104 the pipes run east 104 beneath the 560 floor from G to A through the Turbine Page 42 of 123
TSD 14-016 Revision 0 Building slab where they exit the Turbine Building Oil Room wall at A19 and A21 at 5498 as seen in Figure 38. Figure 48 shows that they exit the Turbine Building slab 6 feet before match line A. Thus, the distance from G to the slab exit is 171.5 feet as seen on Figure 39. They then travel 8 feet east to the pipes center line of the vertical rise. They then rise vertically from 5498 to the 579 elevation (i.e., 294) making the buried pipe length 37 4. The pipes continue eastward to the Crib House wall as seen on M-106 and Figure 48. As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 579 will be cut and removed leaving the buried vertical sections. Drawing M-105 shows the lines traversing east where they pass through the Crib House wall at AA19 and AA21. M-106 and Figure 38 shows it is 2 feet from the center line of the pipe to A. M-105 shows the distance from A to AA as 50 feet for a total of 52 feet that will be removed. M-106 and M-105 shows the Crib House wall to be 4 feet as seen in Figure 48.
Table 41 - Service Water Supply Header Pipe Lengths C26 & C29 OSW-013-48" and OSW-14-48" Segment                            Category        Drawing                Feet Auxiliary Wall Column G                      Embedded    M-103, M-104                  1.5 Column G to TB Slab Exit Near Column A                Embedded    M-103, M-104                170 East to Vertical Rise at Column A                  Buried    M-106                        8.00 Vertical Rise at Column A                      Buried    M-106                      29.33 Totals          208.8 Embedded                171.5 Buried                37.33 The 4 foot penetration length in theCrib House foundation is included in the Crib House Section.
The Auxiliary Building Aerated Drains remaining in the slab were surveyed and had their lengths measured in Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016 (4).
Because the inventory of Auxiliary Building Penetrations also includes those coming from the Unit 1 and Unit 2 Containments, a breakout list of the inventory which is a subset of the Attachment F complete inventory is provided in Attachment I. A summary of all the Auxiliary Building penetrations including those covered in the containment sections for both Units are provided in Table 42.
Table 42 - Summary of Auxiliary Building Affiliated Penetrations Sum of Length          Sum of Int SA      Sum of Void Space Category, End State                meters                  m2                  m3 Bld to Bld Pen                        482.89                585.06                72.34 Buried Pipe                        126.32                  92.68                6.74 Open Sleeve                        199.54                256.67                37.44 Pipe in Sleeve                      157.02                235.71                28.16 Bld to Yard Pen                        924.37                363.69              161.87 Buried Pipe                        924.37                363.69              161.87 Grand Total                          1407.26                948.75              234.21 Page 43 of 123
TSD 14-016 Revision 0 4.5. Turbine Building Penetrations and Piping As seen on Attachment B and Figure 29 there are 10 diameter Fire Protection line penetrations in the north and south wall of the Diesel Generator Buildings at 583 6 at J5 and J35 as show in Drawing M-106. These lines and penetrations are part of the buried pipe inventory. (5)
Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106 The pipes are assumed to be cut flush with the interior and exterior of the 3 foot thick Diesel Generator Building north and south walls.
Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall Section            Length feet      Elevation Pen 35 Sleeve                    3            583.5 Pen 36 Sleeve                    3            583.5 Page 44 of 123
TSD 14-016 Revision 0 There are 4 inch diameter Diesel Oil lines 2DO-006-4 (T68) and 1DO-001-4 (T75) that go through the Turbine Building North and South Walls at G5 and G35 at the 5853 elevation. M-104 show T68 going through a 4 foot thick wall, then traveling buried 45 6 to a where it bends 2 feet East it then rises out of the ground to the 593 elevation. The pipes are to be cut flush with the exterior anterior of the wall laving 4 foot lengths.
Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104 Page 45 of 123
TSD 14-016 Revision 0 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103 Drawing M-104 shows three 8 sleeves through the 18 wall between the Turbine Building and Unit 2 Diesel Generator Building at G5-G10. Drawings M-562 and M-663 show only two oil lines 2DO-004-4" (T69) and 2DO-001-4" (T70) going through the penetrations. Although there appears to be no pipe through the sleeve at T70a, it is included in the inventory.
Page 46 of 123
TSD 14-016 Revision 0 Figure 32 - Unit 2 North Diesel Oil Penetrations There are three Unit 1 oil lines between G32-34 in M-103 and M-214. These are penetrations T72, T73, T74.
Figure 33 - Unit 1 South Diesel Oil Penetrations Page 47 of 123
TSD 14-016 Revision 0 These are routed through the 18 thick wall between the Diesel Generator and Turbine Building in 8 sleeves. M-104 shows 3 8 sleeves between G32 and G35. The pipes will be removed leaving the 8 sleeve openings.
As seen in Figure 27 there is also a 14 diameter sleeve passing through the Diesel Generator Building and Steam Tunnel walls between H&J at columns 10 and 31 (T34b, T34a). As seen on Attachments A and B the walls are 2 feet thick.
The 16 Service Water Return lines T32 and T33 from the Diesel Generator Heat Exchangers are also embedded below the Diesel Generator Building floors as seen in Figure 27. These connect to the 48 Service Water Supply Header on Drawing M-103 and M-104. A graphic with dimensions for U1 T32 pipe is provided as Figure 34.
Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers As seen on M-106 the Diesel Generator Floor is at 5676 and the pipe below it is at 5636 resulting in a vertical rise to the floor penetration at J31 and J9. The horizontal run is 4 feet below the Diesel Generator Building floor. There is also a vertical rise at G31 and G9 from 55310 to 5636 or 9.67 feet. The line runs north under the Turbine Building floor at 55310 which is 62 below the 560 elevation floor. The length from J to G is 42. M-106 shows the floor penetrations at J31 and J9. T32 at J31 is 3+19+ 22 3/8 from J resulting in a length of 35.05 feet. T33 at J9 is inset 3+19+111 from J for a length of 35.33 feet. The runs eastward and north south are found on M-106, M-103, M-104. These total lengths are 183 feet as seen in Table 44. The portion of the pipe under the Diesel Generator building is below the slab in soil.
Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33 T32 U1        T33 U2 Segment                        Feet          Feet Page 48 of 123
TSD 14-016 Revision 0 Vertical 1 Under DG          4            4 Vertical 2 Under DG        9.67          9.67 Length on M-106        35.05        35.33 Length East on M-103 & M-104          16            16 Length North South on M-103 & M-104          118.75      118.75 Total Length      183.5        183.8 All the penetrations on the East Wall of the Turbine Building are concentrated in and around the Oil Room at the centerline of the building. The Unit 2 north penetrations are provided on M-104 and an excerpt from the drawing is provided as Figure 35. The Unit 1 south penetrations are provided on M-103 an excerpt from the drawing is provided as Figure 37. The buried portions of these pipes will be removed with the exception of the 48 inch Service Water Headers C26 and C29, the 20 inch and 4 inch Condensate pipes T103 and T105.
These include spare, 10, 12 and 14 spare penetrations at C16 (T91, T92, T93) and C24 (T99, T100, T101) as seen on Attachments A and B as well as Figure 35 and Figure 37. As seen in Figure 35, Figure 37, and Detail B of M-106 the spare penetrations are 5 feet long extending 6 inches past the 4 foot thick wall on either side. The remaining pipes are assumed to be cut flush with the interior and exterior walls leaving 4 feet of embedded pipe. M-104 shows T102 and T95 running at the 5569 elevation to match line D.
Page 49 of 123
TSD 14-016 Revision 0 Figure 35 - Turbine Building East Wall Penetrations - North Page 50 of 123
TSD 14-016 Revision 0 Figure 36 - T95 and T102 Buried and Embedded Sections As seen in Figure 36, the embedded portion of T95 from the exterior of the wall at the back of the Oil Room to the penetration through the 560 elevation floor is 10+25+354+26 or 7210. The vertical through the 560 floor is 560-5569 or 33. T95 then travels an estimated 13 feet in the Page 51 of 123
TSD 14-016 Revision 0 soil until it rises vertically from the 5569 to the 586 elevation of 118.33 feet as seen in Table 45.
The embedded length of T102 2 foot of wall + 354+26 or 3910.
Table 45 - Estimated Lengths of T95 and T102.
Line Segment                            T95          T102 560' Vertical from 556'9"                                    3.25          3.25 560' Pen to Back of TB                                      72.8          39.8 Back Wall To Vertical in Soil                                  13            6 Vertical to 586' in Soil                                    29.25        29.25 Total                                                      118.33        78.33 Embedded                                                    76.08        43.08 Buried                                                      42.25        35.25 Figure 37 - Turbine Building East Wall Penetrations - South A 20 inch Condensate line and a 4 inch Condensate Pump Recirc line penetrate the wall at A21 5569 and 5583 elevation as shown on M-105 and M-103. The 20 inch Condensate Line supplies the Alternate Feedwater Pumps as shown in drawing M-105 Sheet 2 Section C-C. The pipe exits from the Turbine Page 52 of 123
TSD 14-016 Revision 0 Building slab at elevation 5569 into the soil then travels vertically to the 586 elevation. This line is not included in the TSD 14-015 Attachment 1 listing of buried pipe. M-103 and M-106 Section A-A show the top view and the side view of the pipe existing the Turbine Building these sections are provide in Figure 38.
As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 586 will be cut and removed leaving the buried vertical sections.
Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building Drawing B-559 shows the Oil Room wall exterior is 11 feet from row B which is 14 feet from Row A. As seen in Figure 38, the pipe exits the building at a 45 degree angle this means the pipe exiting the building foundation then bends 90 degrees upward at two feet from Row A. This results in a 69 base and 12 height resulting in a hypotenuse length of 13.77 feet from the 20 to 18 reducer within the wall to the vertical bend upward to the 586 elevation. The vertical pipe length from the 5569 to 586 or 29.25 feet. The buried pipe section of the Condensate from the exit of the Oil Room foundation to the cut line is shown in Table 46. The 4 Condensate line parallels the 20 line but exits the foundation 1.5 feet higher at 5583 or 19 below the 560 floor. Resulting in a vertical length of 279. As seen in Figure 39, the embedded portion in the TB foundation is shown on M-103. Shortly after entering the Turbine Building foundation they run through the slab and emerge on the west side of the 560 floor at G22. M-103 shows 180 feet from column A to G. The 18 T103 penetration is 56 below G making it 1746 long. Other dimension show the distance from the centerline of the pipe forming a 45 degree triangle at 129 long.
Page 53 of 123
TSD 14-016 Revision 0 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105 Page 54 of 123
TSD 14-016 Revision 0 This results in a length of 1619 from A to the 45 degree bend for the 18 pipe. The 4 inch pipe is offset by 2 feet from the 18 pipe resulting in a length of 1599 from A to the 45 degree bend. The 45 degree bend section of each pipe is the hypotenuse of a 45 degree triangle with 129 sides or 18.03 feet. The 4 inch diameter pipe vertical section to the floor is 19 and the 18 pipe vertical section is 33. The lengths, diameters, surface areas and volumes are summarized in Table 46. As seen in Figure 39, the 4 Condensate line T105 runs beneath the floor at the 5583 elevation making it 19 below the floor. The 18 Condensate line T103 runs under the floor at the 5569 elevation making the top of the pipe at the 5576 elevation or 26 below the floor. T106 runs under the floor at the 5569 level, 33 below the 560 floor.
Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes Length ft                  SA ft2                Vol ft3 T103 20"      T105 4" Buried Pipe Section Feet        Feet          20"        4"      20"          4" Wall thickness Inches      0.594        0.237 Diameter feet      1.57          0.29 Wall to 90    13.77        13.77        67.81      12.71    26.58        0.93 Vertical    29.25        27.75      144.06      25.62    56.46        1.88 Total Buried      43.02        41.52      211.86      38.33    83.03        2.82 Embedded Pipe Section        18" Feet      4" Feet        18"        4"      18"          4" Wall thickness Inches          0.562        0.237 Diameter feet      1.41          0.29 Horizontal    161.75        159.75      714.63    147.47    251.25      10.83 Hypotenuse      18.03        18.03        79.66      16.64    28.01        1.22 Vertical      3.25        1.75        14.36      1.62    5.05        0.12 Total Embedded        183.03        179.53      808.66    165.73    284.31      12.17 Totals    226.05        221.05      1020.52    204.05    367.34      14.99 Page 55 of 123
TSD 14-016 Revision 0 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103 The 48 Service Water Supply Headers exiting between B & A at Columns 19 and 21 from under the building at 549 are discussed in the Crib House section.
Aerated Drain piping from equipment drains, floor drains, and sump piping remains in the end state Turbine Building slab below the 560 elevation. The estimated piping lengths and diameters were inventoried in the preparation of FSS Plan 06105B Turbine Building Embedded Piping Drawings used in developing the FSS Plan are as follows: (6)
B-452 Turbine Building Plumbing Basement Floor Plan Unit 1 B-454 Turbine Building Plumbing Diagram Basement Floor Plan Unit 1 B-471 Turbine Building Plumbing Basement Floor Plan Unit 2 B-473 Turbine Building Plumbing Diagram Basement Floor Plan Unit 2 M-103 Zion Station Unit 1Turbine Building Piping, Misc. Piping in Structure Embedded system piping surveyed by this survey plan included the floor drain and equipment drain systems below the 560 elevation of the Turbine Building. These systems consist of inputs and connecting piping that terminates at one of four drain sumps (Unit 1 Equipment Sump, Unit 2 Equipment Sump, Turbine Building Floor Sump and the Fire Sump) beneath the 560 el. floor.
The floor drain system on the 560 el. consists of 26 floor drain inputs, the floor drains from the Clean and Dirty Oil Storage Tank Rooms, the continuation of the Emergency Diesel Generator Fuel Oil Storage Tank Room floor drains from the 567 el., and the continuation of the floor drain systems from the Turbine Building 592, 617 and 642 elevations from where they enter the floor of the 560 el. to their connection to Page 56 of 123
TSD 14-016 Revision 0 the embedded drain piping (approximately 1,250 linear feet of varying diameter drain pipe which connects all floor drain inputs) and terminating at either the Turbine Building Sump or the Fire Sump.
Also included is the Unit 1 equipment drain system consisting of input associated with components located on the 560 and 562 elevations and the common area between Units 1 and 2, the continuation of the Unit 1equipment drains from the 642, 617, and 592 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 300 linear feet of varying diameter equipment drain system piping) terminating at the Unit 1 Equipment Sump.
Also included is the Unit 2 equipment drain system consisting of input associated with components located on the 560 562 elevations, the continuation of the equipment drains from the 642, 617 and 592 elevations of Unit 2 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 200 linear feet of varying diameter equipment drain system piping) terminating at the Unit 2 Equipment Sump.
The polishing filter system drains consist of 2 inputs located in the common area, connected to 2, separate 10 diameter pipe systems that terminate at inputs to the fire sump, total length of 10 diameter pipe is approximately 180 linear feet.
The varying pipe diameters are apparently related to progression in the number of inputs to the different systems (more inputs, increased pipe diameter). The surveys were performed at the discharge end of the pipes in the sumps. During performance of the survey, pipes were found to be larger in diameter than what was identified in the survey plan based on available drawings (6vs 4 and 8vs 6).
The estimated length of pipe was based on the drop from the 560 el. to the lateral pipe run (approximately
: 4) plus the estimated lateral run of the pipe base on turbine building column line dimensions, as the drawings are difficult to read. In some cases, the total length of a given diameter of pipe could not be determined consequently an exaggerated total length was used in order to build conservatism into the survey plan.
The estimated pipe section diameters and lengths are summarized in Table 47.
Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping Penetration                                                                  Pipe Size      Length No.                              Description                          inches OD        Feet T147        U-1 Equip Drain Sump, 6 pipe West Wall                          6        200.00 T148        U-1 Equip Drain Sump, 6 pipe North Wall                          6        100.00 T149        U-2 Equip Drain Sump, 6 pipe West Wall                          6        200.00 T150        Floor Drain Sump, West-most 6 pipe on North Wall                6        100.00 T151        Floor Drain Sump East-most 6 pipe on North Wall                  4        100.00 T152        Fire Sump, South-most 6 pipe on West Wall                        4        150.00 T153        Fire Sump, North-most 6 pipe on West Wall                        8        450.00 T154        Fire Sump, West-most 8 pipe on North Wall                        8        450.00 T155        Fire Sump, West-most 10 pipe on North Wall                      10          80.00 T156        Fire Sump, East-most 10 pipe on North Wall                      10        100.00 The list of Turbine Building affiliated penetrations and piping other than the drains is provided in Attachment J. The calculated lengths, surface areas and void spaces are summarized in Table 48.
Page 57 of 123
TSD 14-016 Revision 0 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes.
Sum of                              Sum of Length        Sum of Int SA    Void Space Category, End State          meters              m2                m3 Bld to Bld Pen                291.56            354.61            43.79 Buried Pipe                204.69            222.34            19.46 Open Sleeve                86.87            132.27            24.33 Bld to Yard Pen              235.59            726.53            13.46 Buried Pipe                158.58            683.81            11.42 Open Sleeve                4.57              4.27              0.32 Pipe in Pen                72.44            38.45            1.72 Grand Total                  527.15          1081.14            57.24 The Turbine Floor drain piping is summarized in Table 49. The inventory of piping is provided at the end of Attachment J.
Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes Category, End          Sum of Length          Sum of Int SA      Sum of Void Space State                  meters                  m2                    m3 Bld Pen                        588.26                302.43                13.13 Embedded Pipe              588.26                302.43                13.13 Grand Total                    588.26                302.43                13.13 4.1. Circulating Water Intake Piping The Circulating Water Supply to the Condensers consist of embedded pipe through the Crib House Wall, buried pipe from the Crib House to the Turbine Building Foundation and Embedded pipe from the Turbine Building foundation as seen in Attachment C. The section below the condensers is shown in Figure 41.
Assuming the 9 foot diameter supply pipes (T109, T110, T120, T121 in Unit 1 and T123a, T123, T133, T134 in Unit 2) are cut above the water table at the 580 elevation and grouted. The floor elevation is 572. The average length to the 12 foot diameter line below 572 to the connection to the 12 foot diameter pipe is conservatively estimated at 26 since some of the surface area extends below the top of the pipes at the 570 elevation. Thus, their total embedded length is 2.5 feet. Notation on M-100 which is retained in Attachment C shows a 1 inch pipe wall thickness for the 9 diameter piping.
The 36 diameter manways to the 12 Diameter Circulating Water Supply line (T83, T85, T87, T88) are 9 feet long if they are cut flush with the concrete as seen in in Figure 41. Figure 41 also shows that each of the four (T111, T122, T143, T124) 12 foot diameter pipes below the condenser. These pipes have a 1.25 inch wall thickness as seen in M-100.
Page 58 of 123
TSD 14-016 Revision 0 Figure 41 - Circ Water Intake Supply to Condensers Each of the 4 pipes has a spherical head whose surface area is calculated using Equation 3.
Equation 3 - Surface Area of Spherical Cap
                                                = 2 Where; r = is the inner radius or 70.75 inches h = is the inner height of 22.75 inches This results in an inner surface are of 10,113.18 square inches for each end bell.
The volume is calculated using Equation 4.
Page 59 of 123
TSD 14-016 Revision 0 Equation 4 - Volume of Spherical Cap
                                                      =      (32 + 2 )
6 Where a equals the inside radius or 70.75 inches and h the inside height or 22.75 inches. The end cap surface areas and volumes are shown in Table 50.
Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers End Bell                                      Pipe                          Totals Length Section      r inches    h inches      SA in2      V in3    inches        SA in2      V in3        SA in2        V in3 T111          70.75        22.75      10113.18    185042      547.5    2.4338E+05 8.6097E+06    2.5350E+05 8.7947E+06 T111b        70.75                                              270      1.2002E+05 4.2459E+06    1.2002E+05 4.2459E+06 T122          70.75        22.75      10113.18    185042      547.5    2.4338E+05 8.6097E+06    2.5350E+05 8.7947E+06 T122b        70.75                                            1002      4.4542E+05 1.5757E+07    4.4542E+05 1.5757E+07 T143          70.75        22.75      10113.18    185042      547.5    2.4338E+05 8.6097E+06    2.5350E+05 8.7947E+06 T143b        70.75                                            1002      4.4542E+05 1.5757E+07    4.4542E+05 1.5757E+07 T124          70.75        22.75      10113.18    185042      547.5    2.4338E+05 8.6097E+06    2.5350E+05 8.7947E+06 T124b          70.75                                              270      1.2002E+05 4.2459E+06    1.2002E+05 4.2459E+06 Drawing B-61 shows a distance of 316 from match line E to the Turbine Building wall just beyond match line D. The embedded length of T111, T122, T143, T124 are as seen on Attachment C. The lengths embedded in concrete are 316+ 87.5 + 56 or 457.5 which is 547.5 inches. As seen on Attachment C the buried portions of pipes T111 and T124 are 54-316 or 367.5 which is 270 inches. The lengths of T122b and T143b are 115-316 or 1002 inches.
Section T112 and T125 cut diagonally South and North Section 4-4 on drawing M-100 provides a side view of the intersection with a 9 long expansion to a 17 foot diameter. M-100 shows the dimension from T111 to the intersection below is 115 minus 54 feet or 61 feet with an estimated 4 feet to the intersection below the joint for an opposite length of 65 feet. The base length is also shown on M-100 as 65 7.75 inches. This results in a hypotenuse length of 925. Minus 14 to the 17 expansion and 9 for the expansion joint provides a length of 695.
Page 60 of 123
TSD 14-016 Revision 0 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127 The average outside diameter of the expansions at T113 and T126 is 146 with a 1.5 inch wall thickness this is an interior diameter of 143 over a 9 length.
Sections T114 and T127 are 17 OD pipes with 1.5 walls for an inner diameter of 169. M-100 shows the base is 88 4.25 inches minus 162 or 722.25. It shows an opposite of 50 feet minus the estimated 4 feet for the upper point and an estimated 10 feet for the lower point equaling 36. The resulting hypotenuse is 808. As seen on section T114 of Attachment C there is an addition 14 to the 12 to 17 expansion for a total length of 948.
The 17 to 9 reducers at T115 and T128 are approximately 83 long with an average diameter or 13. With a pipe wall thickness of 1 the average inside diameter is 1210. The length of the straight sections is estimated at 6 feet with a 9 foot outside diameter and 810 inside diameter.
Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128 Wall                  Length Sect        Dia in      Thick        ID          in        SA in2          V in3 Reducer        156          1          154          99      4.79E+04        1.84E+06 Straight        108          1          106          72      2.40E+04        6.35E+05 Total        171      7.19E+04        2.48E+06 T116 and T129 are approximately 196 long. T117 and T130 are approximately the same length as T115 and T128 at 171 inches long. T118 and T131 are 10 to 9 reducers that are 83 long. T119 and T132 are approximately 14 feet long and have a 10 foot outer diameter.
There are Circulating Water Intake Pipes that connect to the Forebay Drawing B-49 shows a 16 diameter at the exit point from the Forebay. Drawing M-2 shows approximately 50 feet to the shoreline.
Page 61 of 123
TSD 14-016 Revision 0 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2 The summary of the Circulating Water Intake and Supply section noted above and shown in Attachment C have inventories listed in Attachment O. The lengths, surface areas and void space volumes are summarized in Table 52.
Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes Sum of Length          Sum of Int SA      Sum of Void Space Category, End State              meters                    m2                  m3 Circ Water Intake                384.27                4412.09                4393.19 4.2. Circulating Water Discharge Piping Circulating Water Discharge piping in the Turbine Building consists of a 48 inch (T75, T76) and 36 inch stand pipe (T84, T86), a 36 inch manway entrances to the Discharge Tunnel (T135, T136) and two 12 foot interior diameter discharge pipes from the condenser for each Unit (T77, T78, T80, T81). The top view is provided in drawing M-15, the side view is from drawing B-100 as shown in Figure 44 and in Figure 45.
Penetrations T75and T77 are the Unit 2 Circulating Water Discharge Stand Pipe located at F9 and F31 in the Turbine Building as shown in Attachments A, B, C and Figure 44. A side view is provided in Figure 45 from B-100. It can be seen that the pipe runs vertically through the Turbine Building slab from the 592 to 22 above the 5616: elevation at the middle of the 45 degree bend into the discharge tunnel. The vertical drop will be from the 588 elevation to the 5638 elevation. This makes the vertical section 24 4 long as seen in Figure 45. The base of the triangle formed by the slanted section from the Discharge Tunnel wall to the center of the pipe is 108. The vertical drop is 136 this results in a hypotenuse of 14.27 feet forming an overall length of 42.6 feet.
Page 62 of 123
TSD 14-016 Revision 0 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel Page 63 of 123
TSD 14-016 Revision 0 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100 Table 53 - 48 Inch Circulating Water Standpipe Lengths Length Pipe Section            Length Feet    Inches Vertical from 592'                    24.33            292 Slant Base                            10.67 Slant Opp                              13.5 Hypotenuse                            14.27        171.22 Overall Length                        38.60        463.22 The 36 diameter standpipes are vertical and embedded from the 588 elevation to the top of the Discharge Tunnel at 5586 (i.e., 5626-3). This results in a length of 296 for each pipe T135 and T136. B-100 shows that the 12 diameter for the Circ Water Discharge lines is an inside diameter and that they are Page 64 of 123
TSD 14-016 Revision 0 embedded in 5 feet of concrete. It also shows that the 36 access hatch is 1 foot off the floor. Assuming the hatch will not be cut flush to the floor, this results in a 4 foot length.
Each Discharge Tunnel ends at a Valve House near the sheet piling wall as seen on Attachment C. Drawing B-39 shows a 14 diameter Discharge Pipe that travels to the Discharge Diffuser structures in the lake.
Drawing M-2 shows that the distance to the shoreline is bounded at 50 feet. The east west 50 foot dimension is transposed from another part of the drawing as seen in Figure 43.
M-100 shows a 14 diameter pipe has a 0.750 inch wall thickness for the Discharge Pipes.
Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100 The estimated lengths, volumes and interior surface areas of the Circulating Water Discharge Piping are summarized in Error! Reference source not found..
The 48 Service Water Return Line T82 in Unit 1 and T79 in Unit 2 runs through the Turbine Building slab at 55310 elevation as seen on M-103 and M-104 and the excerpt provided as Figure 47. It empties into the Discharge Tunnel.
Page 65 of 123
TSD 14-016 Revision 0 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return The side view of the T82 line entering the Unit 1 Discharge Tunnel is shown in Figure 45 which excerpted from drawing B-100. The Unit 1 T82 dimensions are provided on M-103. The distance east from where it enters the Discharge Tunnel is 138+6 or 198. The line then runs north from Column 31 to Column 20 where it joins the Unit 2 line T82. The north runs distance to column 20 is 31-43+25+273+273+219+219 or 1499. The section that Ts off the north line to the floor penetration at G23 is 134+16-5 or 24 4. The vertical rise from the 55310 to the floor at 560 is 62.
The T82 segment lengths are summarized in Table 54.
Page 66 of 123
TSD 14-016 Revision 0 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths Section                Drawing        Feet Unit 1 Disch Tunnel East              M-103        19.67 Unit 1 Disch Tunnel North              M-103        149.75 Unit 1 Disch Tunnel East              M-103        24.33 Unit 1 Vertical to Floor at G23        M-103          6.17 Total    199.92 The T79 Unit 2 pipe segment lengths are shown on drawing M-104. They are the same dimensions with the exception that M-104 has more length on the southward segment to column 20 where it joins T82 than M-103 has at 31-43+25+273+273+219+219 or 1499.
Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths Section              Drawing          Feet Unit 2 Disch Tunnel East          M-104          19.67 Unit 2 Disch Tunnel South          M-104          149.75 Unit 2 Disch Tunnel East          M-104          24.33 Unit 2 Vertical to Floor at G16    M-104          6.17 Total        199.92 As noted above, both T79 and T82 run under the floor at the 55310 elevation or 62 below the 560 Turbine Building floor. The piping sections inventory for Circulating Discharge Piping are provided in Attachment P. The Circulating Water Discharge piping lengths, surface areas and volumes are summarized in Table 56.
Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay Sum of Length        Sum of Int SA      Sum of Void Space Category, End State                meters                m2                    m3 Circ Water Discharge Pipe                202.40              1074.86                666.09 4.3. Crib House Penetrations and Embedded Piping The estimated pipe section lengths and for the Circulating Water Intake piping shown in Attachment C are described in Section 4.1. As seen in Figure 48 there are two 10 diameter Fire Protection lines OFP-011-10 that pass through the Crib House wall at 5859 C1 and 5819 C7. All the pipes will be cut flush to the interior and exterior walls making them 4 feet in length.
Page 67 of 123
TSD 14-016 Revision 0 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2 There is also a 3" Hot Water Supply OHS-020-3, 3" Hot Water Return OHS-024-3", and 3 Filtered Water line OMU-031-3 at the 5816 elevation. At the 581 elevation there is a 2 Station Air and a 3 Control Air OSA-002-3". Each of these lines will also be cut flush with the exception of the Filtered Water line are within 6 inch sleeves. The inventory of Crib House penetrations is provided in Attachment L. The pipes in the sleeves will be removed leaving the opening of the sleeve. The estimated overall surface areas and volumes using the pipe ID or sleeve IDs is provided in Table 57 Table 57 - Summary of Crib House Penetrations at Match Line AA Sum of Category, End State        Length        Sum of Int      Sum of Void Space meters          SA m2                m3 Bld to Yard Pen                10.97            1.14                2.92 Open Sleeve                  4.88            0.19                0.09 Pipe in Pen                  6.10            0.95                2.83 Grand Total                    10.97            1.14                2.92 Page 68 of 123
TSD 14-016 Revision 0 4.4. Waste Water Treatment Facility Penetrations and Buried Piping The Waste Water Treatment Facility has eight subsurface penetrations as shown in Figure 49 and Figure 50.
The pipe in the yard and the interior of the building will be cut flush with the walls. As seen in Figure 50 from B-1024 the walls are 1 foot thick, making the remaining penetration 1 foot in length. The calculated surface areas and void space volumes are shown in Attachment K.
Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space Category, End        Sum of Length          Sum of Int SA      Sum of Void Space State                meters                    m2                    m3 Bld to Yard Pen              2.44                  0.89                  0.03 Pipe in Pen                2.44                  0.89                  0.03 Grand Total                  2.44                  0.89                  0.03 Page 69 of 123
TSD 14-016 Revision 0 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005 Page 70 of 123
TSD 14-016 Revision 0 Figure 50 - Top View Approximate Penetration Locations B-1024 4.5. Buried Piping Inventory The buried piping associated with the end state structures, such as the service water lines that run under the Main Steam Tunnel slabs, the Condensate, Service Water Supply Headers and Primary Water lines exiting the Turbine Building slab near match line A, Circulating Water Discharge Ice Melting lines, etc. have had the determination of their lengths, surface areas, and void space volumes described in the previous sections. The inventory of buried pipe is provided in Attachment K. The calculated pipe lengths, surface areas and void space volume are summarized in Table 59.
Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces Category, End        Sum of Length        Sum of Int SA      Sum of Void Space State              meters                m2                    m3 Bld to Bld Pen            302.51              894.48                585.08 Buried Pipe            302.51              894.48              585.08 Bld to Yard Pen            1082.95            1047.50              173.29 Buried Pipe            1082.95            1047.50              173.29 Grand Total                1385.46            1941.98              758.37 4.6. Fuel Handling Building The fuel handling building penetrations are described in the Auxiliary Building and Containment calculation sections. The inventory of piping and penetrations affiliated with the Fuel Handling Page 71 of 123
TSD 14-016 Revision 0 Building are provided in Attachment M. The lengths, surface areas and void spaces are summarized in Table 60.
Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces Category, End        Sum of Length            Sum of Int SA    Sum of Void Space State                meters                  m2                m3 Bld to Bld Pen                38.56                13.34              1.34 Buried Pipe                33.56                4.31                0.04 Pipe in Sleeve              5.00                  9.03                1.30 Bld to Yard Pen              797.07                324.12              20.89 Buried Pipe                797.07                324.12              20.89 Grand Total                  835.63                337.46              22.23
: 5. CONCLUSION The complete inventory of end state penetrations and piping along with the estimated lengths, surface areas and void spaces is provided in Attachment F. Attachments A through E provide the overall layout and location of these penetrations. Attachments G through P provide the inventory associated with each piping group. The piping group lengths, surface reas and void space volumes are summarized in Table 61.
Page 72 of 123
TSD 14-016 Revision 0 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes Embedded                  Bld to Bld Pen                Bld to Yard Pen                  Total Void              Surface      Void              Surface    Void                        Void Length  Surface  Volume  Length      Area    Volume    Length      Area    Volume  Length  Surface    Volume 2      3                  2          3                    2        3                    2      3 LTP Pipe Group        TSD Location      m    Area m      m        m        m          m        m          m        m        m  Area m        m U1 CTMT PEN                    Attachment G                                169.20    242.36      32.48                                  169.20  242.36      32.48 U2 CTMT PEN                    Attachment G                                169.20    242.36      32.48                                  169.20  242.36      32.48 U1 Incore Embedded Pipe        Attachment G      8.15    1.05      0.015                                                                  8.15  1.05      0.01 U2 Incore Embedded Pipe        Attachment G      8.15    1.05      0.015                                                                  8.15  1.05      0.01 U1 MS Drains Embedded Pipe    Attachment H    145.93  46.88    1.20                                                                  145.93  46.88      1.20 U2 MS Drains Embedded Pipe    Attachment H    144.41  46.39    1.19                                                                  144.41  46.39      1.19 U1 Tendon Tunnel Embedded Pipe Attachment H    160.02  51.41    1.31                                                                  160.02  51.41      1.31 U2 Tendon Tunnel Embedded Pipe Attachment H    160.02  51.41    1.31                                                                  160.02  51.41      1.31 Auxiliary Building PEN        Attachment I                                482.89    585.06      72.34    924.37      363.69    161.87  1407.26  948.75    234.21 Turbine Building PEN          Attachment J                                291.56    354.61      43.79    235.59      726.53    13.46  527.15 1081.14      57.24 TB Embedded Pipe              Attachment J    588.26  302.43    13.13                                                                588.26  302.43      13.13 WWTF PEN                      Attachment K                                                                2.44        0.89      0.03      2.44  0.89      0.03 Crib House PEN                Attachment L                                                                10.97      1.14      2.92    10.97  1.14      2.92 Spent Fuel PEN                Attachment M                                38.56    13.34      1.34    797.07      324.12    20.89  835.63  337.46      22.23 Buried Pipe                    Attachment N                                302.51    894.48      585.08  1082.95    1047.50    173.29 1385.46 1941.98    758.37 Circ Water Intake              Attachment O                                384.27    4412.09    4393.19                                  384.27 4412.09    4393.19 Circ Water Discharge Pipe      Attachment P                                202.40    1074.86    666.09                                  202.40 1074.86    666.09 Page 73 of 123
TSD 14-016 Revision 0
: 6.      REFERENCES
: 1. TSD 13-005 Unit 1 & 2 Reactor Building Estimated End State Concrete and Liner Volumes and Surface Areas.
: 2. TSD 13-006 Reactor Building Units 1 and 2 End State Concrete and Liner Initial Characterization Source Terms and Distributions.
: 3. TSD 14-005, Backfill Material Specifications.
: 4. Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016.
: 5. TSD 14-015, Buried Pipe Dose Modeling & DCGLs, Revision 1, March 2016.
: 6. FSS Plan 06105B Turbine Building Imbedded Piping.
: 7. ComEd Zion Station Historical Site Assessment, Version 1 - August, 1999.
: 8. 10 CFR 20 Standards for Protection Against Radiation, Subpart ERadiological Criteria for License Termination http://www.nrc.gov/reading-rm/doc-collections/cfr/part020/.
: 9. 10 CFR 61.55 Waste Classification.
: 10. TSD 14-019 Radionuclides of Concern for Soil and Basement Fill Model Source Terms.
: 11. M-5 Zion Station Unit 1 and 2 General Arrangement Plan Ground Floor 592.
: 12. TSD 14-014, Rev 2. End State Surface Areas, Volumes, and Source Terms of Ancillary Buildings, August 2015.
Page 74 of 123
TSD 14-016 Revision 0
: 7. ATTACHMENTS 7.1. Attachment A - Building Penetrations South 7.2. Attachment B - Building Penetrations North 7.3. Attachment C - Building Penetrations East 7.4. Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains 7.5. Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains 7.6. Attachment F - End State Penetration and Piping Inventory 7.7. Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 7.8. Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory 7.9. Attachment I - Auxiliary Building Affiliated Penetrations and Piping 7.10. Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 7.11. Attachment K - Waste Water Treatment Facility 7.12. Attachment L - Crib House Penetrations and Piping 7.13. Attachment M - Fuel Handling Building Affiliated Penetrations, Piping 7.14. Attachment N - Buried Pipe Penetrations and Piping Inventory 7.15. Attachment O - Circulating Water Intake Penetrations and Piping 7.16. Attachment P - Circulating Water Discharge Piping Inventory Page 75 of 123
Attachment A                        TSD # 10-XXX Building Penetrations South                Revision 00 Page 76 of 123
Attachment B                        TSD # 10-XXX Building Penetrations North                Revision 00 Page 77 of 123
Attachment C                        TSD # 14-016 Building Penetrations East                Revision 00 Page 78 of 123
Attachment D                        TSD # 14-016 Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations  Revision 00 Page 79 of 123
Attachment D                      TSD # 14-016 Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 80 of 123
Attachment E                      TSD # 14-016 Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 81 of 123
Attachment E                      TSD # 14-016 Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 82 of 123
Attachment F                                                                                          TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                      MARSSIM                                      Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings        Line Ident No.        System          Category      End Sate    Class    From  To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 A001 M-162, M-172, M-185  OSW-014-24"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3  Aux TB        Service Water              24    0.688  22.624  3.00    G        16    586.00    586.00    17.77    9.42  0.91  1.65  0.27 A002 M-162, M-172, M-185    2FW-027-4"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  Aux TB          Feedwater                4.5    0.237    4.026  3.00    G        16    578.25    578.25      3.16    0.33  0.91  0.29  0.01 A003 M-162, M-172, M-185  OWS-011-2"      Secondary Sample  Bld to Bld Pen  Open Sleeve  Class 2  Aux TB      Secondary Sample            2.375  0.154    2.067  3.00    G        16    586.00    586.00      1.62    0.09  0.91  0.15 0.003 A004    M-182, M-163      OSW-013-24"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Service Water              24    0.688  22.624  3.00    G        23    586.00    586.00    17.77    9.42  0.91  1.65  0.27 A005    M-182, M-163        1FW-027-4"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  TB  Aux        Feedwater                4.5    0.237    4.026  3.00    G        23    588.00    588.00      3.16    0.33  0.91  0.29  0.01 Main A006    M-165, M-187      OFP-012-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3  Stm Aux      Fire Protection            10.75  0.365    10.02  3.00    H        10    571.00    571.00      7.87    1.89  0.91  0.73  0.05 Aux Bld Vents &
A007 M-165, M-171, M-185    1VN-001-4"      Vents and Drains  Bld to Bld Pen  Open Sleeve  Class 2  TB  Aux          Drains                  4.5    0.237    4.026  3.00    G        13    569.75    569.75      3.16    0.33  0.91  0.29  0.01 Aux Bld Vents &
A008 M-165, M-171, M-185    2VN-001-4"      Vents and Drains  Bld to Bld Pen  Open Sleeve  Class 2  TB  Aux          Drains                  4.5    0.237    4.026  3.00    G        13    568.75    568.75      3.16    0.33  0.91  0.29  0.01 A009 M-165, M-171, M-185  OWD-031-3      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1  Aux TB        Waste Disposal              3.5    0.216    3.068  3.00    G        13    573.25    573.25      2.41    0.20  0.91  0.22  0.01 A010 M-165, M-171, M-185  OSW-056-10"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3  Aux TB        Service Water              10.75  0.365    10.02  3.00    G        14    572.25    572.25      7.87    1.89  0.91  0.73  0.05 A011 M-162, M-172, M-185  OWD-039-2"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1  TB  Aux      Waste Disposal            2.375  0.154    2.067  3.00    G        17    574.50    574.50      1.62    0.09  0.91  0.15  0.00 A012    M-165, M-168        OCA-007-3"    Chemical Addition  Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Chemical Feed              3.5    0.216    3.068  3.00    G        17    565.50    565.50      2.41    0.20  0.91  0.22  0.01 A013    M-165, M-174      OPW-020-4"        Primary Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Primary Water              4.5    0.237    4.026  3.00    G        17    573.17    573.17      3.16    0.33  0.91  0.29  0.01 A014    M-165, M-174      2SW-002-20"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Service Water              20    0.594  18.812  3.00    G        17    570.50    570.50    14.77    6.54  0.91  1.37  0.19 A015 M-165, M-171, M-185  OWD-016-6"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1  Aux TB        Waste Disposal            6.625    0.28    6.065  3.00    G        13    571.00    571.00      4.76    0.72  0.91  0.44  0.02 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A016        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3  Aux Stm        Worksheet                14    0.438  13.124  2.00    H        10    571.00    571.00      6.87    2.14  0.61  0.64  0.06 A017    M-182, M-163      OFP-003-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Fire Protection            10.75  0.365    10.02  3.00    G        23    586.50    586.50      7.87    1.89  0.91  0.73  0.05 Main A018    M-166, M-188      OFP-012-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3  Stm Aux      Fire Protection            10.75  0.365    10.02  3.00    H        30    571.00    571.00      7.87    1.89  0.91  0.73  0.05 A019    M-165, M-174      OPW-042-3"        Primary Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Primary Water              3.5    0.216    3.068  3.00    G        17    573.42    573.42      2.41    0.20  0.91  0.22  0.01 A020    M-182, M-166        OVC-071-3"      Vacuum Control    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Vacuum Control              3.5    0.216    3.068  3.00    G        24    576.25    576.25      2.41    0.20  0.91  0.22  0.01 A021    M-182,M-166        ODW-003-3"        Demin Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux        Demin Water                3.5    0.216    3.068  3.00    G        24    568.75    568.75      2.41    0.20  0.91  0.22  0.01 A022    M-182, M-166      OPW-005-4"        Primary Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux      Line with Flange            4.5    0.237    4.026  3.00    G        24    568.75    568.75      3.16    0.33  0.91  0.29  0.01 A023    M-182, M-166        OWD-20-6"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1  TB  Aux      Waste Disposal            6.625    0.28    6.065  3.00    G        24    573.00    573.00      4.76    0.72  0.91  0.44  0.02 A024    M-182, M-166      OCD-068-18"        Condensate    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux        Condensate                18    0.562  16.876  3.00    G        24    571.00    571.00    13.25    5.30  0.91  1.23  0.15 Service Water Supply A025    M-180, M-166,      OSW-019-36"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3  TB  Aux          Header                  36      0.75    34.5  3.00    G        23    575.00    575.00    27.10  21.21  0.91  2.52  0.60 Service Water Supply to Service Water to DG                                                  Diesel Generator Heat A027 M-102, M-168. M-185  OSW-008-12"            Hxs        Bld to Bld Pen  Buried Pipe  Class 3  DG  Aux        Exchangers              12.75  0.406  11.938  74.50    G        10    554.75    567.50    232.84  57.91  22.71 21.63  1.64 Service Water to DG                                                    Service Water to DG A028 M-102, M-168. M-185  OSW-008-12"            Hxs        Bld to Bld Pen  Buried Pipe  Class 3  DG  Aux            Hxs                  12.75  0.406  11.938  77.67    G        10    553.33    567.50    242.75  60.37  23.67 22.55  1.71 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pool -                                                      Spent Fuel Pool -
A029 197, M-106 Sect K-K    1SF-017-2"        Demin Water    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB        Demin Water              2.375  0.154    2.067  89.58    R        24    570.58    583.33    48.48    2.09  27.31  4.50  0.06 Service Water Supply to Diesel Generator Heat A030    M-102, M-169      OSW-001-12"      Service Water    Bld to Bld Pen  Buried Pipe  Class 3  DG  Aux        Exchangers              12.75  0.406  11.938  74.50    G        30    554.75    567.50    232.84  57.91  22.71 21.63  1.64 Service Water Supply to Diesel Generator Heat A031    M-102, M-169      OSW-001-12"      Service Water    Bld to Bld Pen  Buried Pipe  Class 3  DG  Aux        Exchangers              12.75  0.406  11.938  77.67    G        30    553.33    567.50    242.75  60.37  23.67 22.55  1.71 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A034        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3  Aux Stm        Worksheet                14    0.438  13.124  2.00    H        30    571.00    571.00      6.87    1.88  0.61  0.64  0.05 M-107 Sh 1, 2 ,3 , M-A036 197, M-106 Sect K-K    1SI-012-24"    Safety Injection  Bld to Yard Pen Buried Pipe Unimpacted  Aux SFB      Safety Injection            24    0.688  22.624  70.11    R        24    570.00    0.00    415.27  195.73  21.37 38.58  5.54 Page 83 of 123
Attachment F                                                                                        TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                        MARSSIM                                      Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings          Line Ident No.      System          Category      End Sate    Class    From  To      Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A037  197, M-106 Sect K-K  1AD-149-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  30.75    R        24    571.00  Unknown      4.05    0.14  2.93  0.38 0.004 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A038  197, M-106 Sect K-K  1AD-148-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  30.75    R        24    571.00  Unknown    11.68    0.39  8.44  1.08  0.01 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A039  197, M-106 Sect K-K  1AD-147-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  17.75    R        24    571.00  Unknown      7.48    0.25  5.41  0.70  0.01 M-107 Sh 1, 2 ,3 , M-A040  197, M-106 Sect K-K    1AD-146-4"      Aerated Drain    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB      Aerated Drain              4.5    0.237    4.026  124.52    R        24    569.33    584.00    131.25  11.01  37.96 12.19  0.31 M-107 Sh 1, 2 ,3 , M-A041  197, M-106 Sect K-K  1SA-014-1 1/2"      Station Air    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB        Service Air              1.9    0.145    1.61  94.17    R        24    569.33    583.00    39.69    1.33  28.70  3.69  0.04 M-107 Sh 1, 2 ,3 , M-A042  197, M-106 Sect K-K    ODW-100-2"        Demin Water      Bld to Yard Pen Buried Pipe  Class 3  Aux SFB      Demin Water              2.375  0.154    2.067  63.55    R        24    570.58    484.00    34.39    1.48  19.37  3.19  0.04 M-107 Sh 1, 2 ,3 , M-A043  197, M-106 Sect K-K    OFP-016-4"      Fire Protection  Bld to Yard Pen Buried Pipe  Class 3  Aux SFB      Fire Protection            4.5    0.237    4.026  91.08    R        24    570.58    584.00    96.00    8.05  27.76  8.92  0.23 M-107 Sh 1, 2 ,3 , M-A044  197, M-106 Sect K-K    1SW-181-2"      Service Water    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB      Service Water              2.375  0.154    2.067  92.58    R        24    570.58    584.00    50.10    2.16  28.22  4.65  0.06 M-107 Sh 1, 2 ,3 , M-A046  197, M-106 Sect K-K  01A-004-1 1/2"    Instrument Air    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB      Instrument Air              1.9    0.145    1.61  94.00    R        24    570.58    584.00    39.62    1.33  28.65  3.68  0.04 M-107 Sh 1, 2 ,3 , M-A047  197, M-106 Sect K-K      1SF-022-3"    Spent Fuel Pool    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB  Spent Fuel Pit Cooling          3.5    0.216    3.068  84.42    R        24    569.33    583.00    67.80    4.33  25.73  6.30  0.12 M-107 Sh 1, 2 ,3 , M-A048  197, M-106 Sect K-K      1SF-008-2"    Spent Fuel Pool    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB  Spent Fuel Pit Cooling        2.375  0.154    2.067  86.00    R        24    569.33    583.00    46.54    2.00  26.21  4.32  0.06 M-107 Sh 1, 2 ,3 , M-A049  197, M-106 Sect K-K    1CC-078-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2  Aux SFB  Component Cooling            10.75  0.365    10.02  128.08    R        24    570.58    584.00    335.99  70.14  39.04 31.21  1.99 M-107 Sh 1, 2 ,3 , M-A050  197, M-106 Sect K-K    1CC-080-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2  Aux SFB  Component Cooling            10.75  0.365    10.02  130.92    R        24    570.58    584.00    343.42  71.69  39.90 31.91  2.03 M-107 Sh 1, 2 ,3 , M-A051  260, M-106 Sect K-K    2SI-012-24"    Safety Injection  Bld to Yard Pen Buried Pipe Unimpacted  Aux SFB    Safety Injection            24    0.688  22.624  70.11    R        16    570.00    573.00    415.27  195.73  21.37 38.58  5.54 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A052  260, M-106 Sect K-K  2AD-149-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  30.75    R        16    571.00  Unknown      4.05    0.14  2.93  0.38 0.004 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A053  260, M-106 Sect K-K  2AD-148-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  30.75    R        16    571.00  Unknown    11.68    0.39  8.44  1.08  0.01 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell A054  260, M-106 Sect K-K  2AD-147-1 1/2"      Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1  Aux SFB      Aerated Drain              1.9    0.145    1.61  17.75    R        16    571.00  Unknown      7.48    0.25  5.41  0.70  0.01 M-107 Sh 1, 2 ,3 , M-A055  260, M-106 Sect K-K      2SF-008-2"    Spent Fuel Pool    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB  Spent Fuel Pit Cooling        2.375  0.154    2.067  113.25    R        16    569.33    583.00    61.28    2.64  34.52  5.69  0.07 M-107 Sh 1, 2 ,3 , M-A056  260, M-106 Sect K-K      2SF-022-3"    Spent Fuel Pool    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB  Spent Fuel Pit Cooling          3.5    0.216    3.068  111.00    R        16    569.33    583.00    89.16    5.70  33.83  8.28  0.16 M-107 Sh 1, 2 ,3 , M-A057  260, M-106 Sect K-K      0SF-012-3"    Spent Fuel Pool    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB  Spent Fuel Pit Cooling          3.5    0.216    3.068  109.50    R        16    569.33    583.00    87.95    5.62  33.38  8.17  0.16 M-107 Sh 1, 2 ,3 , M-                                                                                      Decon Pad Drain to A058  260, M-106 Sect K-K    0CT-061-2"      Waste Drain      Bld to Yard Pen Buried Pipe  Class 1  Aux SFB    Chem Drain Tank              2.375  0.154    2.067  89.75    R        16    569.33    583.00    48.57    2.09  27.36  4.51  0.06 M-107 Sh 1, 2 ,3 , M-A059  260, M-106 Sect K-K    2CC-078-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2  Aux SFB  Component Cooling            10.75  0.365    10.02  108.58    R        16    570.58    584.00    284.84  59.46  33.10 26.46  1.68 M-107 Sh 1, 2 ,3 , M-A060  260, M-106 Sect K-K    2CC-080-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2  Aux SFB  Component Cooling            10.75  0.365    10.02  106.42    R        16    570.58    584.00    279.16  58.27  32.44 25.93  1.65 M-107 Sh 1, 2 ,3 , M-A061  260, M-106 Sect K-K    2DW-008-3"      Demin Water      Bld to Yard Pen Buried Pipe  Class 3  Aux SFB  Demineralized Water            3.5    0.216    3.068  128.25    R        16    569.33    583.00    103.01    6.58  39.09  9.57  0.19 M-107 Sh 1, 2 ,3 , M-A062  197, M-106 Sect K-K    2AD-146-4"      Aerated Drain    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB      Aerated Drain              4.5    0.237    4.026  129.67    R        16    570.58    584.00    136.67  11.46  39.52 12.70  0.32 M-107 Sh 1, 2 ,3 , M-A063  260, M-106 Sect K-K    2DW-014-3"      Demin Water      Bld to Yard Pen Buried Pipe  Class 3  Aux SFB  Demineralized Water            3.5    0.216    3.068  126.67    R        16    570.58    583.00    101.74    6.50  38.61  9.45  0.18 M-107 Sh 1, 2 ,3 , M-A064  260, M-106 Sect K-K  OWD-059-2 1/2"    Waste Disposal    Bld to Yard Pen Buried Pipe  Class 1  Aux SFB    Waste Disposal              2.875  0.203    2.469  123.67    R        16    570.58    584.00    79.94    4.11  37.69  7.43  0.12 M-107 Sh 1, 2 ,3 , M-A065  260, M-106 Sect K-K    2SW-243-3"      Service Water    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB      Service Water              3.5    0.216    3.068  124.67    R        16    569.33    584.00    100.13    6.40  38.00  9.30  0.18 M-107 Sh 1, 2 ,3 , M-A066  260, M-106 Sect K-K  2SA-012-1 1/2"      Station Air    Bld to Yard Pen Buried Pipe  Class 3  Aux SFB        Service Air              1.9    0.145    1.61  124.50    R        16    569.33    583.00    52.48    1.76  37.95  4.88  0.05 Fire Line Below to C001 M-105 SH 1 & 2, M-271  OFP-011-10"      Fire Protection  Bld to Yard Pen Pipe in Pen  Class 3  Crib Yard        ForeBay            0    10.75  0.365    10.02  4.00    AA      111.00  581.75    581.75      0.87    2.19  1.22  0.08  0.06 C002    M-106, M-272        OSA-002-3"        Station Air    Bld to Yard Pen Open Sleeve  Class 3  Crib Yard      Station Air        6    3.5    0.216    3.068  4.00    AA      111.00  581.00    581.00      0.52    0.79  1.22  0.05  0.02 C003    M-106, M-272              0            Control Air    Bld to Yard Pen Open Sleeve  Class 3  Crib Yard      Control Air        6    2.375  0.154    2.067  4.00    AA      111.00  581.00    581.00      0.52    0.79  1.22  0.05  0.02 Page 84 of 123
Attachment F                                                                                          TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space          Int  Void Pen                                                                                          MARSSIM                                      Size    OD      Wall  Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.        Drawings          Line Ident No.        System          Category      End Sate    Class  From    To        Description      inches inches Thickness  inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 C004      M-106, M-272        OHS-020-3"          Hot Water      Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard  3" Hot Water Supply      6    3.5    0.216    3.068  4.00    AA    111.00  581.50    581.50      0.52    0.79  1.22  0.05  0.02 C005      M-106, M-272        OHS-024-3"          Hot Water      Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard  3" Hot Water Return      6    2.375  0.154    2.067  4.00    AA    111.00  581.50    581.50      0.52    0.79  1.22  0.05  0.02 C006      M-106, M-272        OMU-031-3"        Filtered Water  Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard      Filtered Water      0    3.5    0.216    3.068  4.00    AA    111.00  581.50    581.50      0.27    0.21  1.22  0.02  0.01 Fire Line Below to C007      M-106, M-272        OFP-011-10"      Fire Protection  Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard          ForeBay          0    10.75  0.365    10.02  4.00    AA    111.00  585.75    585.75      0.87    2.19  1.22  0.08  0.06 Service Water Supply M-104 & M-105 sh 1,                  Service Water Supply                                                    Header Aux Pen to C026      M-102, M-168        OSW-014-48"      Header Under TB    Bld to Yard Pen Buried Pipe  Class 3  Aux  Yard        Under TB                48    0.625    46.75 171.50    G      19    549.67    549.67    174.92  2044.35  52.27 16.25 57.89 M-104 & M-105 sh 1,                                                                                          Service Water Supply C026c    M-102, M-168        OSW-014-48"        Service Water    Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard    Header Crib Pen        0    48    0.625    46.75  4.00    AA      19.00  579.00    579.00      4.08    47.68  1.22  0.38  1.35 Service Water Supply Service Water Supply                                                        Header at TB C026a M-105 SH 1 & 2, M-272  OSW-014-48"            Header      Bld to Yard Pen Buried Pipe  Class 3  Aux  Yard      Foundation Exit            48    0.625    46.75  37.33    C      19    579.00    549.67    38.08  445.03  11.38  3.54 12.60 Service Water Supply M-104 & M-105 sh 1,                  Service Water Supply                                                    Header Aux Pen to C029      M-102, M-168        OSW-013-48"      Header Under TB    Bld to Yard Pen Buried Pipe  Class 3  Aux  Yard        Under TB                48    0.625    46.75 171.50    G      21    549.67    549.67    174.92  2044.35  52.27 16.25 57.89 M-104 & M-105 sh 1,                                                                                          Service Water Supply C029c    M-102, M-168        OSW-013-48"        Service Water    Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard    Header Crib Pen        0    48    0.625    46.75  4.00    AA      21.00  579.00    579.00      4.08    47.68  1.22  0.38  1.35 Service Water Supply Service Water Supply                                                        Header at TB C029a M-105 SH 1 & 2, M-272  OSW-013-48"            Header      Bld to Yard Pen Buried Pipe  Class 3  Aux  Yard      Foundation Exit            48    0.625    46.75  37.33    C      21    579.00    549.67    38.08  445.03  11.38  3.54 12.60 U1 P001      M-281, M-661        1-FP-037-4"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3 CTMT  Aux  Fire Protection          10    4.5    0.237    4.026  4.83    107      253    577.50    577.50    12.65    2.64  1.47  1.18  0.07 U1 P002      M-281, M-661            Spare                N/A        Bld to Bld Pen  Open Sleeve  Class 2 CTMT  Aux  Spare                      6      0        0        0    4.83    98-30  261-30  588.83    588.83      7.59    0.95  1.47  0.71  0.03 U1 P003      M-281, M-661            Spare                N/A        Bld to Bld Pen  Open Sleeve  Class 2 CTMT  Aux  Spare                      6      0        0        0    4.83    98-15  263-45  577.50    577.50      7.59    0.95  1.47  0.71  0.03 U1        Boron Injection Tank to P004      M-281, M-661        1-S1-090-3"      Safety Injection  Bld to Bld Pen  Open Sleeve  Class 1 CTMT  Aux  Cold Legs                  8    3.5    0.438    2.624  4.83    94      266    577.50    577.50    10.12    1.69  1.47  0.94  0.05 Main    U1 P005      M-281, M-661        1-MS-001-34"        Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Main Steam                50    34    1.15625  31.6875  4.00    213      147    579.50    579.50    52.36    54.54  1.22  4.86  1.54 Main    U1 P006      M-281, M-661        1-MS-002-34"        Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Main Steam                50    34    1.15625  31.6875  4.00    213      147    579.50    579.50    52.36    54.54  1.22  4.86  1.54 Main    U1 P007      M-281, M-661      1-MS-003-35 1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Main Steam                50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36    54.54  1.22  4.86  1.54 Main    U1 P008      M-281, M-661      1-MS-004-35 1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Main Steam                50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36    54.54  1.22  4.86  1.54 Main    U1 P009      M-281, M-661        1-FW-014-16"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Feedwater                32    16    1.218    13.564  4.00    213      147    584.58    584.58    33.51    22.34  1.22  3.11  0.63 Main    U1 P010      M-281, M-661        1-FW-017-16"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Feedwater                32    16    1.218    13.564  4.00    213      147    584.58    584.58    33.51    22.34  1.22  3.11  0.63 Main    U1 P011      M-281, M-661        1-FW-011-16"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Feedwater                32    16    1.218    13.564  4.00    333      27    584.58    584.58    33.51    22.34  1.22  3.11  0.63 Main    U1 P012      M-281, M-661        1-FW-022-16"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2  Stm  CTMT  Feedwater                32    16    1.218    13.564  4.00    333      27    586.83    586.83    33.51    22.34  1.22  3.11  0.63 Reactor Coolant No. 1 Residual Heat                                          U1        Loop to Residual Heat P017      M-281, M-661        1-RH-015-14"          Removal      Bld to Bld Pen  Open Sleeve  Class 1 CTMT  Aux  Removal Pumps            28    14    0.438    13.124  4.83    107      253    584.25    584.25    35.43    20.67  1.47  3.29  0.59 U1        Cavity Fill Pump 1A P018      M-281, M-661        1-CF-004-10"        Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 CTMT  Aux  Discharge                18    10.75  0.365    10.02  4.83  102-45  257-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 Component Cooling U1        Water Supply Header to P019      M-281, M-661        1-CC-091-6"    Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 CTMT  Aux  RCPs                      12    6.625    0.28    6.065  4.83    107      253    586.83    586.83    15.18    3.80  1.47  1.41  0.11 U1        Cavity Fill Pump 1B P020      M-281, M-661        1-CF-003-10"        Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 CTMT  Aux  Discharge                18    10.75  0.365    10.02  4.83  100-45  259-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U1 P021      M-281, M-661            Spare                N/A        Bld to Bld Pen  Open Sleeve  Class 2 CTMT  Aux  Spare                    28      0        0        0    4.83    98-30  261-30  584.25    584.25    35.43    20.67  1.47  3.29  0.59 Residual Heat Residula Heat                                          U1        Exchanger to RC Loop P022      M-281, M-661        1-RH-006-12"          Removal      Bld to Bld Pen  Open Sleeve  Class 1 CTMT  Aux  Cold Legs                28    12.75  0.406    11.938  4.83    98-30  261-30  580.08    580.08    35.43    20.67  1.47  3.29  0.59 U1        RC Pumps to Comp P023      M-281, M-661        1-CC-106-6"    Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 CTMT  Aux  Cooling Pump Suction      12    6.625    0.28    6.065  4.83  100-45  259-15  586.83    586.83    15.18    3.80  1.47  1.41  0.11 Page 85 of 123
Attachment F                                                                                      TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                            Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                            MARSSIM                                    Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings          Line Ident No.        System        Category      End Sate      Class  From  To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 U1      Safety Inj Pumps to RC P024    M-281, M-661          1-SI-104-4"    Safety Injection Bld to Bld Pen  Open Sleeve    Class 1 CTMT Aux Loop Hot Leg              14    4.5    0.438    3.624  4.83    107    253    588.83    588.83    17.72    5.17  1.47  1.65  0.15 U1      RC Pumps to Comp P033    M-281, M-661          1-CC-104-3"    Component Cooling  Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Cooling Pump Suction      12    3.5    0.216    3.068  4.83  102-45'  257-15  588.83    588.83    15.18    3.80  1.47  1.41  0.11 U1 P034    M-281, M-661        1-DW-006-2"        Demin Water    Bld to Bld Pen  Open Sleeve    Class 3 CTMT Aux Demin Water              12    2.375  0.154    2.067  4.83    96-15'  263-45  588.83    588.83    15.18    3.80  1.47  1.41  0.11 B-278, M-7, B-223, M-                                                                              U1      Recirculating Sump P035        170,              1SI-008-20"            Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT Aux Suction                  24    20    0.594  18.812  51.17    135    225    561.25    561.25    251.99  98.76  15.60 23.41  2.80 B-278, M-7, B-223, M-                                                                              U1      Cavity Flood Sump P036        170,              1CF-002-20"            Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT Aux Suction                  24    20    0.594  18.812  50.75    135    225    561.25    561.25    249.94  97.96  15.47 23.22  2.77 B-278, M-7, B-223, M-                                                                              U1      Cavity Flood Sump P037        170,              1CF-001-20"            Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT Aux Suction                  24    20    0.594  18.812  50.83    135    225    561.25    561.25    250.35  98.12  15.49 23.26  2.78 CTMT Sump Pump U1      Dischage to Aux Bld Flr P042    M-281, M-661        1-WO-95-1 1/2"    Rad Discharge    Bld to Bld Pen  Open Sleeve    Class 1 CTMT Aux Drain Analysis Tank        6    1.9    0.145    1.61  4.83  104-45  255-15  577.50    577.50      7.59    0.95  1.47  0.71  0.03 RC Drain Pump U1      Discharge to Hold-Up P043    M-281, M-661          1-DT-036-3"      Rad Discharge    Bld to Bld Pen  Open Sleeve    Class 1 CTMT Aux Tank                      8    3.5    0.216    3.068  4.83    107    253    580.08    580.08    10.12    1.69  1.47  0.94  0.05 M-281, B-213 Detail 4,                                                                              U1 P049        M-661                    0              Cavity      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT SFB Fuel Transfer Tube        24    24    0.688  22.624  8.21      90    270    578.54    578.54    48.62  22.92  2.50  4.52  0.65 U1 P050    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    10      0      0        0    4.83    96-15'  263-45  580.08    580.08    12.65    2.64  1.47  1.18  0.07 Containment                                            U1 P054    M-281, M-661          1-CS-063-2"          Pressure    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Containment Pressure      6    2.375  0.154    2.067  4.83  109-15'  250-45  586.83    586.83      7.59    0.95  1.47  0.71  0.03 U1 P056    M-281, M-661          1-VF-132-2"      Filtered Vents  Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Filtered Vents            8    2.375  0.154    2.067  4.83  100-45'  250-15  580.08    580.08    10.12    1.69  1.47  0.94  0.05 U1 P064    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    10      0      0        0    4.83      94    266    586.83    586.83    12.65    2.64  1.47  1.18  0.07 1-VC-033,043,                                                              U1      RC Pump Seal Water P066    M-281, M-661          052E, 085-2"        Seal Water    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Supply Lines              14    14    0.437  13.126  4.83  102-45'  257-15  580.08    580.08    17.72    5.17  1.47  1.65  0.15 U1 P067    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    18      0      0        0    4.83  108-15'  249-45  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U1      Aux Feedwater to Steam P068    M-281, M-661          1-FW-018-3"        Feedwater    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Gen 1C                    14    3.5    0.438    2.624  4.83  100-45'  259-15  577.50    577.50    17.72    5.17  1.47  1.65  0.15 U1      Aux Feedwater to Steam P069    M-281, M-661          1-FW-015-3"        Feedwater    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Gen 1A                    14    3.5    0.438    2.624  4.83  109-15'  250-45  577.50    577.50    17.72    5.17  1.47  1.65  0.15 Refueling Cavity Drain U1      to Purification Pump P070    M-281, M-661          1-DT-032-3"      Cavity Drain    Bld to Bld Pen  Open Sleeve    Class 1 CTMT Aux Suction                  14    3.5    0.216    3.068  4.83  102-45'  257-15  577.50    577.50    17.72    5.17  1.47  1.65  0.15 U1      Steam Generator P071    M-281, M-661      1-BD-001-2 1/2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Blowdown                  14    2.875  0.276    2.323  4.83  104-45'  255-15  588.83    588.83    17.72    5.17  1.47  1.65  0.15 U1 P073    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    18      0      0        0    4.83  104-45'  255-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U1      Aux Feedwater to Steam P074    M-281, M-661          1-FW-012-3"        Feedwater    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Gen 1D                    14    3.5    0.438    2.624  4.83  104-45'  255-15  586.83    586.83    17.72    5.17  1.47  1.65  0.15 U1      Accumulator Tank P076    M-282, M-662        1-SS-026-3/8"      Sample Line    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Sample                    14    0.675  0.065    0.545  4.83  109-15'  250-45  588.83    588.83    17.72    5.17  1.47  1.65  0.15 U1 P081    M-281, M-661          1-VN-008-2"    Vent Non-filtered Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Non-Filtered Vents        8    2.375  0.154    2.067  4.83  109-15'  250-45  580.08    580.08    10.12    1.69  1.47  0.94  0.05 U1 P084    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    10      0      0        0    4.83      94    266    588.83    588.83    12.65    2.64  1.47  1.18  0.07 U1 P085    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    10      0      0        0    4.83  100-45'  259-45  588.83    588.83    12.65    2.64  1.47  1.18  0.07 U1      Press Stem, Press Liq, P086    M-282, M-661      1-SS-001,2,3-3/8"    Sample Line    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux RC Hot Leg Samples        10    0.675  0.065    0.545  4.83  102-45'  257-15  586.83    586.83    12.65    2.64  1.47  1.18  0.07 U1 P087    M-281, M-661              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    10      0      0        0    4.83    96-15'  263-45  584.25    584.25    12.65    2.64  1.47  1.18  0.07 U1      Heating System Hot P088    M-281, M-661          1-HS-030-2"          Heating    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Water Supply              12    2.375  0.218    1.939  4.83    98-30'  261-30  586.83    586.83    15.18    3.80  1.47  1.41  0.11 U1      Heating System Hot P089    M-281, M-661          0-HS-053-2"          Heating    Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Water Return              12    2.375  0.218    1.939  4.83    96-15'  263-45  586.83    586.83    15.18    3.80  1.47  1.41  0.11 U1 P090    M-282, M-662              Spare              N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT Aux Spare                    28      0      0        0    4.83      94    266    584.25    584.25    35.43  20.67  1.47  3.29  0.59 Page 86 of 123
Attachment F                                                                                        TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                        MARSSIM                                    Size    OD      Wall  Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings          Line Ident No. System        Category      End Sate      Class  From  To        Description      inches inches Thickness  inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 Main  U1  Blowdown Steam P091    M-281, M-661      1-BD-007-2 1/2" SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A              16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown Steam P092    M-281, M-661        1-BD-008-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A              16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown Steam P093    M-281, M-661        1-BD-006-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C              16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown Steam P094    M-281, M-661      1-BD-005-2 1/2" SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C              16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown Steam P095    M-281, M-661        1-BD-007-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A              14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U1  Blowdown Steam P096    M-281, M-661        1-BD-005-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C              14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U1  Blowdown Steam P097    M-281, M-661        1-BD-003-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D              14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U1  Blowdown Steam P098    M-281, M-661        1-BD-001-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B              14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.12 U1 P103    M-282, M-662            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                      8      0        0        0  4.83  98-30'  261-30  577.50    577.50    10.12    1.69  1.47  0.94  0.05 U1 P104    M-282, M-662        1-MS-018-6"  Reactor Coolant  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux SIM to Aux F.S. Pumps    24    6.625  0.432    5.761  4.83    94      266    580.08    580.08    30.37  15.18  1.47  2.82  0.43 Residual Heat Residula Heat                                          U1      Exchanger to RC Loop P105    M-282, M-662        1-SI-011-10"    Removal      Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Hot Legs                  18    10.75  1.125      8.5  4.83  104-45  255-15  580.08    580.08    22.78    8.54  1.47  2.12  0.24 Main  U1  Steam Generator P112    M-282, M-662        1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Blowdown Sample          16    0.675  0.065    0.545  4.00    213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U1  Steam Generator P113    M-282, M-662        1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Blowdown Sample          16    0.675  0.065    0.545  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown (Steam P115    M-282, M-662      1-BD-003-2 1/2" SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D)            16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown (Steam P116    M-282, M-662        1-BD-004-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D)            16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown (Steam P117    M-282, M-662        1-BD-002-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B)            16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U1  Blowdown (Steam P118    M-282, M-662      1-BD-001-2 1/2" SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B)            16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 B-278, M-7, B-223, M-                                                                          U1      Recirculating Sump P123          170,            1SI-007-20"        Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594    18.812  52.00    135    225    561.25    561.25    256.10  100.37  15.85 23.79  2.84 B-278, M-7, B-223, M-                                                                          U1      Recirculating Sump P124          170,            1SI-009-20"        Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594    18.812  52.83    135    225    561.25    561.25    260.20  101.98  16.10 24.17  2.89 Embedded              U1  U1 P125        B-234            1AD-??-???        Drain          Bld Pen          Pipe      Class 1 CTMT CTMT Incore Sump Pipe          1.9    1.9    0.145      1.61  26.74    0        0    542.50    542.50    11.27    0.53  8.15  1.05  0.01 Main  U1  Steam to Aux FW P127    M-282, M-662        1-MS-018-6"    Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Pumps                    16    6.625  0.432    5.761  4.00    213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U1  Steam to Aux FW P128    M-282, M-662        1-MS-017-6"    Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Pumps                    16    6.625  0.432    5.761  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.16 U2 P201    M-281, M-661        2-FP-037-4"  Fire Protection  Bld to Bld Pen  Open Sleeve    Class 3 CTMT  Aux Fire Protection          10    4.5    0.237    4.026  4.83    107    253    577.50    577.50    12.65    2.64  1.47  1.18  0.07 U2 P202    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                      6      0        0        0  4.83    98-30  261-30  588.83    588.83      7.59    0.95  1.47  0.71  0.03 U2 P203    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                      6      0        0        0  4.83    98-15  263-45  577.50    577.50      7.59    0.95  1.47  0.71  0.03 U2      Boron Injection Tank to P204    M-281, M-661        2-S1-090-3"  Safety Injection Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Cold Legs                  8    3.5    0.438    2.624  4.83    94      266    577.50    577.50    10.12    1.69  1.47  0.94  0.05 Main  U2 P205    M-281, M-661        2-MS-001-34"    Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Main Steam                50    34    1.15625  31.6875  4.00    213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.54 Main  U2 P206    M-281, M-661        2-MS-002-34"    Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Main Steam                50    34    1.15625  31.6875  4.00    213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.54 Main  U2 P207    M-281, M-661      2-MS-003-35 1/2"  Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Main Steam                50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.54 Main  U2 P208    M-281, M-661      2-MS-004-35 1/2"  Main Steam    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Main Steam                50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.54 Main  U2 P209    M-281, M-661        2-FW-014-16"    Feedwater      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Feedwater                32    16    1.218    13.564  4.00    213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.63 Page 87 of 123
Attachment F                                                                                        TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                        MARSSIM                                    Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings          Line Ident No.      System        Category      End Sate      Class  From  To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 Main  U2 P210    M-281, M-661        2-FW-017-16"      Feedwater    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Feedwater                32    16    1.218  13.564  4.00    213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.63 Main  U2 P211    M-281, M-661        2-FW-011-16"      Feedwater    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Feedwater                32    16    1.218  13.564  4.00    333      27    584.58    584.58    33.51  22.34  1.22  3.11  0.63 Main  U2 P212    M-281, M-661        2-FW-022-16"      Feedwater    Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Feedwater                32    16    1.218  13.564  4.00    333      27    586.83    586.83    33.51  22.34  1.22  3.11  0.63 Reactor Coolant No. 1 Residula Heat                                          U2      Loop to Residual Heat P217    M-281, M-661        2-RH-015-14"        Removal      Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Removal Pumps            28    14    0.438  13.124  4.83    107    253    584.25    584.25    35.43  20.67  1.47  3.29  0.59 U2      Cavity Fill Pump 1A P218    M-281, M-661        2-CF-004-10"      Cavity Fill  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Discharge                18    10.75  0.365    10.02  4.83  102-45  257-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 Component Cooling U2      Water Supply Header to P219    M-281, M-661        2-CC-091-6"  Component Cooling Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux RCPs                      12    6.625    0.28    6.065  4.83    107    253    586.83    586.83    15.18    3.80  1.47  1.41  0.11 U2      Cavity Fill Pump 1B P220    M-281, M-661        2-CF-003-10"      Cavity Fill  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Discharge                18    10.75  0.365    10.02  4.83  100-45  259-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U2 P221    M-281, M-661            Spare            N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    28      0        0        0    4.83    98-30  261-30  584.25    584.25    35.43  20.67  1.47  3.29  0.59 Residual Heat Residula Heat                                          U2      Exchanger to RC Loop P222    M-281, M-661        2-RH-006-12"        Removal      Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Cold Legs                28    12.75  0.406  11.938  4.83    98-30  261-30  580.08    580.08    35.43  20.67  1.47  3.29  0.59 U2      RC Pumps to Comp P223    M-281, M-661        2-CC-106-6"  Component Cooling Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Cooling Pump Suction      12    6.625    0.28    6.065  4.83  100-45  259-15  586.83    586.83    15.18    3.80  1.47  1.41  0.11 U2      Safety Inj Pumps to RC P224    M-281, M-661          2-SI-104-4"  Safety Injection Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Loop Hot Leg              14    4.5    0.438    3.624  4.83    107    253    588.83    588.83    17.72    5.17  1.47  1.65  0.15 U2      RC Pumps to Comp P233    M-281, M-661        2-CC-104-3"  Component Cooling Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Cooling Pump Suction      12    3.5    0.216    3.068  4.83  102-45'  257-15  588.83    588.83    15.18    3.80  1.47  1.41  0.11 U2 P234    M-281, M-661        2-DW-006-2"      Demin Water    Bld to Bld Pen  Open Sleeve    Class 3 CTMT  Aux Demin Water              12    2.375  0.154    2.067  4.83    96-15'  263-45  588.83    588.83    15.18    3.80  1.47  1.41  0.11 B-278, M-7, B-223, M-                                                                            U2      Recirculating Sump P235        170,            2SI-008-20"          Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594  18.812  51.17    135    225    561.25    561.25    251.99  98.76  15.60 23.41  2.80 B-278, M-7, B-223, M-                                                                            U2      Cavity Flood Sump P236        170,            2CF-002-20"          Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594  18.812  50.75    135    225    561.25    561.25    249.94  97.96  15.47 23.22  2.77 B-278, M-7, B-223, M-                                                                            U2      Cavity Flood Sump P237        170,            2CF-001-20"          Drain      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594  18.812  50.83    135    225    561.25    561.25    250.35  98.12  15.49 23.26  2.78 CTMT Sump Pump U2      Dischage to Aux Bld Flr P242    M-281, M-661      2-WO-95-1 1/2"    Rad Discharge  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Drain Analysis Tank        6    1.9    0.145    1.61  4.83  104-45  255-15  577.50    577.50      7.59    0.95  1.47  0.71  0.03 RC Drain Pump U2      Discharge to Hold-Up P243    M-281, M-661        2-DT-036-3"    Rad Discharge  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Tank                      8    3.5    0.216    3.068  4.83    107    253    580.08    580.08    10.12    1.69  1.47  0.94  0.05 M-281, B-213 Detail 4,                                                                          U2 P249        M-661                  0            Cavity      Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  SFB Fuel Transfer Tube        24    24    0.688  22.624  8.21      90    270    578.54    578.54    48.62  22.92  2.50  4.52  0.65 U2 P250    M-281, M-661            Spare            N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    10      0        0        0    4.83    96-15'  263-45  580.08    580.08    12.65    2.64  1.47  1.18  0.07 Containment                                            U2 P254    M-281, M-661        2-CS-063-2"        Pressure    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Containment Pressure      6    2.375  0.154    2.067  4.83  109-15'  250-45  586.83    586.83      7.59    0.95  1.47  0.71  0.03 U2 P256    M-281, M-661        2-VF-132-2"    Filtered Vents  Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Filtered Vents            8    2.375  0.154    2.067  4.83  100-45'  250-15  580.08    580.08    10.12    1.69  1.47  0.94  0.05 U2 P264    M-281, M-661            Spare            N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    10      0        0        0    4.83      94    266    586.83    586.83    12.65    2.64  1.47  1.18  0.07 2-VC-033,043,                                                            U2      RC Pump Seal Water P266    M-281, M-661        052E, 085-2"      Seal Water    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Supply Lines              14    2.375  0.344    1.687  4.83  102-45'  257-15  580.08    580.08    17.72    5.17  1.47  1.65  0.15 U2 P267    M-281, M-661            Spare            N/A      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    18      0        0        0    4.83  108-15'  249-45  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U2      Aux Feedwater to Steam P268    M-281, M-661        2-FW-018-3"      Feedwater    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Gen 1C                    14    3.5    0.438    2.624  4.83  100-45'  259-15  577.50    577.50    17.72    5.17  1.47  1.65  0.15 U2      Aux Feedwater to Steam P269    M-281, M-661        2-FW-015-3"      Feedwater    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Gen 1A                    14    3.5    0.438    2.624  4.83  109-15'  250-45  577.50    577.50    17.72    5.17  1.47  1.65  0.15 Refueling Cavity Drain U2      to Purification Pump P270    M-281, M-661        2-DT-032-3"      Cavity Drain  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Suction                  14    3.5    0.216    3.068  4.83  102-45'  257-15  577.50    577.50    17.72    5.17  1.47  1.65  0.15 U2      Steam Generator P271    M-281, M-661      2-BD-001-2 1/2"  SG Blowdown    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Blowdown                  14    2.875  0.276    2.323  4.83  104-45'  255-15  588.83    588.83    17.72    5.17  1.47  1.65  0.15 Page 88 of 123
Attachment F                                                                                      TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                          MARSSIM                                    Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings          Line Ident No.      System          Category      End Sate      Class  From  To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 U2 P273    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    18      0      0        0    4.83  104-45'  255-15  584.25    584.25    22.78    8.54  1.47  2.12  0.24 U2      Aux Feedwater to Steam P274    M-281, M-661        2-FW-012-3"        Feedwater      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Gen 1D                  14    3.5    0.438    2.624  4.83  104-45'  255-15  586.83    586.83    17.72    5.17  1.47  1.65  0.15 U2      Accumulator Tank P276    M-282, M-662        2-SS-026-3/8"    Sample Line    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Sample                  14    0.675  0.065    0.545  4.83  109-15'  250-45  588.83    588.83    17.72    5.17  1.47  1.65  0.15 U2 P281    M-281, M-661        2-VN-008-2"    Vent Non-filtered Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Non-Filtered Vents        8    2.375  0.154    2.067  4.83  109-15'  250-45  580.08    580.08    10.12    1.69  1.47  0.94  0.05 U2 P284    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    10      0      0        0    4.83      94    266    588.83    588.83    12.65    2.64  1.47  1.18  0.07 U2 P285    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    10      0      0        0    4.83  100-45'  259-45  588.83    588.83    12.65    2.64  1.47  1.18  0.07 U2      Press Stem, Press Liq, P286    M-282, M-661      2-SS-001,2,3-3/8"  Sample Line    Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux RC Hot Leg Samples      10    0.675  0.065    0.545  4.83  102-45'  257-15  586.83    586.83    12.65    2.64  1.47  1.18  0.07 U2 P287    M-281, M-661            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    10      0      0        0    4.83    96-15'  263-45  584.25    584.25    12.65    2.64  1.47  1.18  0.07 U2      Heating System Hot P288    M-281, M-661        2-HS-030-2"        Heating      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Water Supply            12    2.375  0.218    1.939  4.83    98-30'  261-30  586.83    586.83    15.18    3.80  1.47  1.41  0.11 U2      Heating System Hot P289    M-281, M-661        0-HS-053-2"        Heating      Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Water Return            12    2.375  0.218    1.939  4.83    96-15'  263-45  586.83    586.83    15.18    3.80  1.47  1.41  0.11 U2 P290    M-282, M-662            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    28      0      0        0    4.83      94    266    584.25    584.25    35.43  20.67  1.47  3.29  0.59 Main  U2  Blowdown Steam P291    M-281, M-661      2-BD-007-2 1/2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A            16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown Steam P292    M-281, M-661        2-BD-008-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A            16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown Steam P293    M-281, M-661        2-BD-006-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C            16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown Steam P294    M-281, M-661      2-BD-005-2 1/2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C            16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown Steam P295    M-281, M-661        2-BD-007-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1A            14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U2  Blowdown Steam P296    M-281, M-661        2-BD-005-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1C            14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U2  Blowdown Steam P297    M-281, M-661        2-BD-003-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D            14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.12 Main  U2  Blowdown Steam P298    M-281, M-661        2-BD-001-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B            14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.12 U2 P303    M-282, M-662            Spare            N/A        Bld to Bld Pen  Open Sleeve    Class 2 CTMT  Aux Spare                    8      0      0        0    4.83    98-30'  261-30  577.50    577.50    10.12    1.69  1.47  0.94  0.05 U2 P304    M-282, M-662        2-MS-018-6"    Reactor Coolant  Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux SIM to Aux F.S. Pumps    24    6.625  0.432    5.761  4.83      94    266    580.08    580.08    30.37  15.18  1.47  2.82  0.43 Residual Heat Residula Heat                                            U2      Exchanger to RC Loop P305    M-282, M-662        2-SI-011-10"      Removal      Bld to Bld Pen  Open Sleeve    Class 1 CTMT  Aux Hot Legs                18    10.75  1.125      8.5  4.83  104-45  255-15  580.08    580.08    22.78    8.54  1.47  2.12  0.24 Main  U2  Steam Generator P312    M-282, M-662        2-SS-041-3/8"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Blowdown Sample          16    0.675  0.065    0.545  4.00    213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U2  Steam Generator P313    M-282, M-662        2-SS-041-3/8"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Blowdown Sample          16    0.675  0.065    0.545  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown (Steam P315    M-282, M-662      2-BD-003-2 1/2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D)            16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown (Steam P316    M-282, M-662        2-BD-004-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1D)            16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown (Steam P317    M-282, M-662        2-BD-002-2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B)            16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 Main  U2  Blowdown (Steam P318    M-282, M-662      2-BD-001-2 1/2"    SG Blowdown      Bld to Bld Pen  Open Sleeve    Class 2  Stm CTMT Generator 1B)            16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.16 B-278, M-7, B-223, M-                                                                            U2      Recirculating Sump P323          170,            2SI-007-20"        Drain        Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594  18.812  52.00    135    225    561.25    561.25    256.10  100.37  15.85 23.79  2.84 B-278, M-7, B-223, M-                                                                            U2      Recirculating Sump P324          170,            2SI-009-20"        Drain        Bld to Bld Pen Pipe in Sleeve  Class 1 CTMT  Aux Suction                  24    20    0.594  18.812  52.83    135    225    561.25    561.25    260.20  101.98  16.10 24.17  2.89 Embedded              U2  U2 P325        B-234            2AD-??-???          Drain          Bld Pen          Pipe      Class 1 CTMT CTMT Incore Sump Pipe        1.9    1.9    0.145    1.61  26.74      0      0    542.50    542.50    11.27    0.53  8.15  1.05  0.01 Page 89 of 123
Attachment F                                                                                        TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space          Int  Void Pen                                                                                        MARSSIM                                      Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.        Drawings        Line Ident No.        System          Category      End Sate    Class  From  To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 Main  U2  Steam to Aux FW P327      M-282, M-662      2-MS-018-6"        Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm CTMT  Pumps                    16    6.625  0.432    5.761  4.00    213      147    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Main  U2  Steam to Aux FW P328      M-282, M-662      2-MS-017-6"        Main Steam      Bld to Bld Pen  Open Sleeve  Class 2  Stm CTMT  Pumps                    16    6.625  0.432    5.761  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.16 Service Water Return from Diesel Generator T032    M-103 & M-106            0            Service Water    Bld to Bld Pen  Buried Pipe  Class 3  TB  DG      Heat Exchangers              16      0.5      15  183.47    G        31    553.83    567.50    720.48  225.15  55.92  66.93  6.38 Service Water Return from to Diesel Generator Heat T033    M-104 & M-106            0            Service Water    Bld to Bld Pen  Buried Pipe  Class 3  TB  DG          Exchangers                16      0.5      15  183.75    G        10    553.83    567.50    721.58  225.50  56.01  67.04  6.39 Main T034a        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3  DG  Stm        Blank Sleeve              14        0      14    2.00    H        31    587.75    587.75      7.33    2.14  0.61  0.68  0.06 Main T034b        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3  DG  Stm        Blank Sleeve              14        0      14    2.00    H        10    587.75    587.75      7.33    2.14  0.61  0.68  0.06 T035      M-106, M-107            0          Fire Protection  Bld to Yard Pen Pipe in Pen  Class 3  DG  Yard      Fire Protection            10.75  0.365    10.02  3.00    J        5    583.50    584.50      7.87    1.64  0.91  0.73  0.05 T036      M-106, M-107            0          Fire Protection  Bld to Yard Pen Pipe in Pen  Class 3  DG  Yard      Fire Protection            10.75  0.365    10.02  3.00    J        35    583.50    584.50      7.87    1.64  0.91  0.73  0.05 Diesel Oil Tank Fill Line length to 588' T068      M-104, M-562        2DO-006-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG  Yard        elevation                4.5    0.237    4.026  4.00    G        5    585.25    593.00      4.22    0.35  1.22  0.39  0.01 T069  M-104, M-562, M-663    2DO-004-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG    TB          Diesel Oil                8        0        0    1.50    G        6    585.17    585.17      3.14    0.52  0.46  0.29  0.01 T070  M-104, M-562, M-663    2DO-001-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG    TB          Diesel Oil                8        0        0    1.50    G        7    585.17    585.17      3.14    0.52  0.46  0.29  0.01 T070a        M-104              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3  DG    TB        Open Sleeve                8        0        0    1.50    G        8    585.17    585.17      3.14    0.52  0.46  0.29  0.01 T071  M-103, M-214, M-244    1DO-010-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG    TB          Diesel Oil                8        0        0    1.50    G        32    585.17    585.17      3.14    0.52  0.46  0.29  0.01 T072  M-103, M-214, M-244    1DO-003-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG    TB          Diesel Oil                8        0        0    1.50    G        33    585.17    585.17      3.14    0.52  0.46  0.29  0.01 T073  M-103, M-214, M-244    1DO-002-4"          Diesel Oil    Bld to Bld Pen  Open Sleeve  Class 3  DG    TB          Diesel Oil                8        0        0    1.50    G        34    585.17    585.17      3.14    0.52  0.46  0.29  0.01 Diesel Oil see buried T074      M-103, M-214        1DO-001-4"          Diesel Oil    Bld to Yard Pen Buried Pipe  Class 3  DG  Yard            pipe                  4.5    0.237    4.026  52.25    G        35    585.25    593.00    55.07    4.62  15.93  5.12  0.13 U2 Embedded                Disch T075    M-104, B-68, B-100        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun      Unit 2 Stand Pipe            48    0.625    46.75  38.60    F        9    588.00    553.00    472.45  460.15  11.77  43.89 13.03 U1 Embedded                Disch T076    M-103, B-62, B-100        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun      Unit 1 Stand Pipe            48    0.625    46.75  38.60    F        31    588.00    553.00    472.45  460.15  11.77  43.89 13.03 Unit 2 Circulating U2  Water Discharge from M-15, M-101, B-100, M-                                                      Embedded                Disch Condenser to Discharge T077          104                0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                145.5    0.75    144    5.00    E        9    562.00    557.00    188.50  565.49  1.52  17.51 16.01 Unit 2 Circulating U2  Water Discharge from M-15, M-101, B-100, M-                                                      Embedded                Disch Condenser to Discharge T078          104                0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                145.5    0.75    144    5.00    E        9    562.00    557.00    188.50  565.49  1.52  17.51 16.01 U2    Unit 2 Service Water Embedded                Disch    Return to Discharge T079    B-66, B-68, M-104          0            Service Water    Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                  48    0.625    46.75  199.92    E        9    553.83    560.00  2446.80  2383.09  60.93 227.32 67.48 Unit 1 Circulating U1  Water Discharge from Embedded                Disch Condenser to Discharge T080  M-780, M-101, M-103        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                145.5    0.75    144    5.00    E        31    562.00    557.00    188.50  565.49  1.52  17.51 16.01 Unit 1 Circulating U1  Water Discharge from Embedded                Disch Condenser to Discharge T081  M-780, M-101, M-103        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                145.5    0.75    144    5.00    E        31    562.00    557.00    188.50  565.49  1.52  17.51 16.01 U1    Unit 1 Service Water Embedded                Disch    Return to Discharge T082    B-62, B-64, M-103          0            Service Water    Bld to Bld Pen    Pipe      Class 3  TB  Tun          Tunnel                  48    0.625    46.75  199.92    E        33    553.83    560.00  2446.80  2383.09  60.93 227.32 67.48 Unit 2 Blind Flange M-780, M-100, M-101,                                                        Embedded                          Man Entry to Circ T083          M-104                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib      Water Intake              36    0.375    35.25  9.00    D        6    564.00    564.00    83.06    60.99  2.74  7.72  1.73 Page 90 of 123
Attachment F                                                                                          TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                                Revision 00 Y or    X or Unit 1  Unit 2                      Interior    Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface    Space          Int  Void Pen                                                                                          MARSSIM                                      Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.        Drawings          Line Ident No.      System            Category      End Sate    Class  From  To          Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 U2 M-780, B-68, B-100, B-                                                      Embedded                Disch    Unit 2 Circ Water T084        68, M-104              0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun  Discharge Stand Pipe            36    0.375    35.25  29.50    D        9    588.00    558.50    272.24    199.93  8.99  25.29  5.66 Unit 2 Blind Flange M-780, M-100, M-101,                                                        Embedded                          Man Entry to Circ T085          M-104                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib        Water Intake              36    0.375    35.25  9.00    D        13    564.00    564.00    83.06    60.99  2.74  7.72  1.73 U1 Embedded                Disch    Unit 1 Circ Water T086  M-15, B-62, B-100, B-66      0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB  Tun  Discharge Stand Pipe            36    0.375    35.25  29.50    D        31    588.00    558.50    272.24    199.93  8.99  25.29  5.66 Unit 1 Blind Flange M-15, M-100, M-101, B-                                                      Embedded                          Man Enttry to Circ T087        64, M-103              0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib        Water Intake              36    0.375    35.25  9.00    D        27    564.00    564.00    83.06    60.99  2.74  7.72  1.73 Unit 1 Blind Flange M-15, M-100, M-101, B-                                                      Embedded                          Man Enttry to Circ T088        62, M-103              0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib        Water Intake              36    0.375    35.25  9.00    D        34    564.00    564.00    83.06    60.99  2.74  7.72  1.73 Spares Blanks Left T091  M-104, M-106 Det B        Spare              N/A        Bld to Yard Pen Open Sleeve  Class 3  TB  Yard            Intact                10.75  0.365    10.02  5.00    C        16    585.00    585.00    13.12      2.74  1.52  1.22  0.08 Spares Blanks Left T092  M-104, M-106 Det B        Spare              N/A        Bld to Yard Pen Open Sleeve  Class 3  TB  Yard            Intact                12.75  0.406  11.938  5.00    C        16    586.00    586.00    15.63      3.89  1.52  1.45  0.11 Spares Blanks Left T093  M-104, M-106 Det B        Spare              N/A        Bld to Yard Pen Open Sleeve  Class 3  TB  Yard            Intact                14    0.438  13.124  5.00    C        16    585.00    585.00    17.18      4.70  1.52  1.60  0.13 Fibercast Makeup T094          M-104                0          Make-Up Demin      Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard  Demin Waste Discharge            8.625  0.322    7.981  4.00    C        17    586.00    586.00      8.36      1.39  1.22  0.78  0.04 Primary Water Storage T095      M-104, M-105              0          Primary Water    Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard            Tank                  6.625    0.28    6.065  118.33    C        18    556.75    556.75    187.89    23.74  36.07  17.46  0.67 T096          M-103                0            Oil Seperator    Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard    Oil Seperator Tank            10.75  0.365    10.02  4.00    C        23    586.00    586.00    10.49      2.19  1.22  0.97  0.06 Fibercast Makeup T097          M-103                0          Make-Up Demin      Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard  Demin Waste Discharge            8.625  0.322    7.981  4.00    C        23    586.00    586.00      8.36      1.39  1.22  0.78  0.04 Waste Discharge (WD) from Lake Discharge Tank to Discharge T098          M-103                0          Waste Discharge    Bld to Yard Pen Pipe in Pen  Class 1  TB  Yard            Tunnel                6.625    0.28    6.065  4.00    C        24    586.00    586.00      6.35      0.80  1.22  0.59  0.02 T099  M-103, M-106 Det B        Spare              N/A        Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard            Spares                10.75  0.365    10.02  5.00    C        24    585.00    585.00    13.12      2.74  1.52  1.22  0.08 T100  M-103, M-106 Det B        Spare              N/A        Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard            Spares                12.75  0.406  11.938  5.00    C        24    586.00    586.00    15.63      3.89  1.52  1.45  0.11 T101  M-103, M-106 Det B        Spare              N/A        Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard            Spares                  14    0.438  13.124  5.00    C        24    585.00    585.00    17.18      4.70  1.52  1.60  0.13 Primary Water Supply T102      M-104, M-105              0          Primary Water    Bld to Yard Pen Pipe in Pen  Class 3  TB  Yard      Header to RCP              6.625    0.28    6.065  78.33    C        17    586.00    586.00    124.38    15.72  23.88  11.56  0.45 Condensate to Alternate M-105 SH 1 & SH 2, M-                                                                                          Feedwater Pumps-T103          103                  0            Condensate      Bld to Yard Pen Buried Pipe  Class 3  TB  Yard        Buried Section              20    0.594  18.812  226.05    B        21    586.00    586.00  1020.52    367.34  68.90  94.81  10.40 T104          M-104                0          Waste Discharge    Bld to Yard Pen Pipe in Pen  Class 1  TB  Yard    Lake Discharge tank            6.625    0.28    6.065  4.00    C        17    586.00    586.00      6.35      0.80  1.22  0.59  0.02 Condensate Pump T105          M-103                0            Condensate      Bld to Yard Pen Buried Pipe  Class 3  TB  Yard            Recirc                  4.5    0.337    3.826  221.05    G        22    560.00    586.00  6219.50    14.99  67.38 577.81  0.42 To condensate transfer T106          M-103                0            Condensate      Bld to Yard Pen Buried Pipe  Class 3  TB  Yard    and makeup pumps              12.75  0.406  11.938  20.93    D        22    560.00    583.25    65.41    16.27  6.38  6.08  0.46 Embedded                      Unit 1 Circ water supply T109          M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib      pipe to Condenser            108      1      106    2.50    E        34    564.00    564.00    291.38    643.47  3.20  27.07  18.22 Embedded                      Unit 1 Circ water supply T110          M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib      pipe to Condenser            108      1      106    2.50    E        34    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded T111      M-100, B-61              0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib  Unit 1 Circ water pipe          144    1.25    141.5  45.63    E        34    564.00    564.00  1760.39  5089.54  13.91 163.55 144.12 T111b      M-100, B-61              0        Circ Water Intake  Bld to Bld Pen  Buried Pipe  Class 3  TB  Crib  Unit 1 Circ water pipe          144    1.25    141.5  22.50    E        34    564.00    564.00    833.50  2457.10  6.86  77.44  69.58 Embedded T112          M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib  Unit 1 Circ water pipe          144    1.25    141.5  124.20    E        34    564.00    564.00  4600.94  13563.19  37.86 427.44 384.07 Embedded                        Unit 1 Circ water pipe T113          M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB  Crib    12' to 17' expansion          174      1.5    171    9.00    E        34    558.00    558.00    402.91  1435.36  2.74  37.43  40.64 T114          M-100                0        Circ Water Intake  Bld to Bld Pen  Buried Pipe  Class 3  TB  Crib  Unit 1 Circ water pipe          204      1.5    201    94.67    B        31    558.00    558.00  4981.52  20860.11  28.85 462.80 590.69 T115      M-100, M-272        1CW-001-108"    Circ Water Intake  Bld to Bld Pen  Buried Pipe  Class 3  TB  Crib  Unit 1 Circ water pipe          108      1      106    14.25  AA        20    558.00    558.00    499.12  1434.84  4.34  46.37  40.63 Page 91 of 123
Attachment F                                                                                            TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                                  Revision 00 Y or    X or Unit 1  Unit 2                      Interior    Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface    Space          Int  Void Pen                                                                                      MARSSIM                                          Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.        Drawings        Line Ident No.      System          Category      End Sate    Class  From    To          Description        inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3  meters  m2    m3 T116      M-100, M-272      1CW-002-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 1 Circ water pipe          108      1      106    19.50  AA        22    558.00    558.00    541.14  1195.02  5.94  50.27  33.84 T117      M-100, M-272      1CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 1 Circ water pipe          108      1      106    14.25  AA        24    558.00    558.00    395.45    873.28  4.34  36.74  24.73 T118        M-100          1CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 1 Circ water pipe          114      1      112    8.25    AA        26    558.00    558.00    241.90    564.44  2.51  22.47  15.98 T119        M-100          1CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 1 Circ water pipe          120      1      118    14.00  AA        26    558.00    558.00    432.49  1063.21  4.27  40.18  30.11 Embedded                          Unit 1 Circ water supply T120        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2.50    E        26    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded                          Unit 1 Circ water supply T121        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2,5    E        26    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded                          Unit 2 Circ water supply T122      M-100, B-61            0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              144    1.25    141.5  45.63    E        6    564.00    564.00  1760.39  5089.54  13.91 163.55 144.12 Unit 2 Circ water supply T122b      M-100, B-61            0        Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib      pipe to Condenser              144    1.25    141.5  83.50    E        6    564.00    564.00  1760.39  5089.54  25.45 163.55 144.12 Embedded                          Unit 2 Circ water supply T123        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2.50    E        6    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded                          Unit 2 Circ water supply T123a        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2.50    E        6    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded T124      M-100, B-61            0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib    Unit 2 Circ water pipe          144    1.25    141.5  45.63    E        6    564.00    564.00  1760.39  5089.54  13.91 163.55 144.12 T124b      M-100, B-61            0        Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          144    1.25    141.5  22.50    E        6    564.00    564.00  1760.39  5089.54  6.86 163.55 144.12 Embedded                            Unit 2 Circ water pipe T125        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib    12' to 17' expansion            144    1.25    141.5  124.20    E        6    564.00    564.00  4600.94  13563.19  37.86 427.44 384.07 Embedded                            Unit 2 Circ water pipe T126        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib    12' to 17' expansion            174      1.5    171    9.00    B        8    558.00    558.00    402.91  1435.36  2.74  37.43  40.64 T127        M-100                0        Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          204      1.5    201    94.67    A        12    558.00    558.00  4981.52  20860.11  28.85 462.80 590.69 T128      M-100, M-272      2CW-001-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          108      1      106    14.25  AA        20    558.00    558.00    499.12  1434.84  4.34  46.37  40.63 T129      M-100, M-272      2CW-002-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          108      1      106    19.50  AA        18    558.00    558.00    541.14  1195.02  5.94  50.27  33.84 T130      M-100, M-272      2CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          108      1      106    14.25  AA        16    558.00    558.00    395.45    873.28  4.34  36.74  24.73 T131        M-100          2CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          114      1      112    8.25    AA        14    558.00    558.00    241.90    564.44  2.51  22.47  15.98 T132        M-100          2CW-003-108"    Circ Water Intake  Bld to Bld Pen Buried Pipe  Class 3  TB    Crib    Unit 2 Circ water pipe          120      1      118    14.00  AA        14    558.00    558.00    432.49  1063.21  4.27  40.18  30.11 Embedded                          Unit 2 Circ water supply T133        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2.50    E        14    572.00    572.00    291.38    643.47  3.20  27.07  18.22 Embedded                          Unit 2 Circ water supply T134        M-100                0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib      pipe to Condenser              108      1      106    2.50    E        14    572.00    572.00    291.38    643.47  3.20  27.07  18.22 U2 Embedded                    Disch      Unit 2 Hatch to T135  M-104, B-68, B-100        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB    Tun      Discharge Tunnel              36    0.375    35.25  4.00    D        9    562.00    562.00    36.91    27.11  1.22  3.43  0.77 U1 Embedded                    Disch      Unit 1 Hatch to T136  M-103, B-62, B-100        0        Circ Water Discharge Bld to Bld Pen    Pipe      Class 3  TB    Tun      Discharge Tunnel              36    0.375    35.25  4.00    D        31    562.00    562.00    36.91    27.11  1.22  3.43  0.77 U2 Disch            Unit 2 Circ Water T137  M-1, M-2, B-39, M-100      0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Lake  Discharge Pipe to Lake            168    0.75    166.5  50.00  GG        9    568.58    568.58  2179.48  7560.07  15.24 202.48 214.08 U1 Disch            Unit 1 Circ Water T138  M-1, M-2, B-39, M-100      0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Lake  Discharge Pipe to Lake            168    0.75    166.5  50.00  GG        31    568.58    568.58  2179.48  7560.07  15.24 202.48 214.08 U2 Disch          Unit 2 Circ Water Ice T139        M-100                0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay      Melting Pipe                144    1.25    141.5  80.42  GG        31    569.00    569.00  2978.98  8781.78  24.51 276.76 248.67 U2 Disch          Unit 2 Circ Water Ice T140        M-100                0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay      Melting Pipe                96        1      94    25.00  GG        31    569.00    569.00    615.23  1204.82  7.62  57.16  34.12 Disch          Unit 1 Circ Water Ice T141        M-100                0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay      Melting Pipe                144    1.25    141.5  80.42  GG        31    569.00    569.00  2978.98  8781.78  24.51 276.76 248.67 Disch          Unit 1 Circ Water Ice T142        M-100                0        Circ Water Discharge Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay      Melting Pipe                96        1      94    25.00  GG        31    569.00    569.00    615.23  1204.82  7.62  57.16  34.12 Embedded T143      M-100, B-61            0        Circ Water Intake  Bld to Bld Pen    Pipe      Class 3  TB    Crib    Unit 2 Circ water pipe          144    1.25    141.5  45.63    E        14    564.00    564.00  1760.39  5089.54  13.91 163.55 144.12 Page 92 of 123
Attachment F                                                                                          TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space          Int  Void Pen                                                                                    MARSSIM                                        Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.      Drawings        Line Ident No.      System        Category      End Sate    Class  From    To        Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 T143b    M-100, B-61            0        Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3  TB    Crib  Unit 2 Circ water pipe          144    1.25    141.5  83.50    E        14    564.00    564.00  1760.39  5089.54  25.45 163.55 144.12 Circ Water Intake to T144      M-2, B-49              0        Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake        Forebay                  192    0.75    190.5  50.00  GG        16    558.00    558.00  2493.64  9896.63  15.24 231.67 280.24 Circ Water Intake to T145      M-2, B-49              0        Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake        Forebay                  192    0.75    190.5  50.00  GG        20    558.00    558.00  2493.64  9896.63  15.24 231.67 280.24 Circ Water Intake to T146      M-2, B-49              0        Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake        Forebay                  192    0.75    190.5  50.00  GG        24    558.00    558.00  2493.64  9896.63  15.24 231.67 280.24 M-103 , B-454, B-452,                                                Embedded                          U-1 Equip Drain Sump, T147    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB    6 pipe West Wall              6      0.28    5.44  200.00  0.00      0    560.00    557.00    284.84    32.28  60.96  26.46  0.91 M-103 , B-454, B-452,                                                Embedded                          U-1 Equip Drain Sump, T148    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB    6 pipe North Wall              6      0.28    5.44  100.00  0.00      0    560.00    557.00    142.42    16.14  30.48  13.23  0.46 M-103 , B-454, B-452,                                                Embedded                          U-2 Equip Drain Sump, T149    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB    6 pipe West Wall              6      0.28    5.44  200.00  0.00      0    560.00    557.00    284.84    32.28  60.96  26.46  0.91 Floor Drain Sump, M-103 , B-454, B-452,                                                Embedded                          West-most 6 pipe on T150    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB        North Wall                  6      0.28    5.44  100.00  0.00      0    560.00    557.00    142.42    16.14  30.48  13.23  0.46 Floor Drain Sump East-M-103 , B-454, B-452,                                                Embedded                          most 4 pipe on North T151    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB            Wall                    4    0.237    3.526  100.00  0.00      0    560.00    557.00    92.31    6.78  30.48  8.58  0.19 M-103 , B-454, B-452,                                                Embedded                          Fire Sump, South-most T152    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB  4 pipe on West Wall            4    0.237    3.526  150.00  0.00      0    560.00    557.00    138.47    10.17  45.72  12.86  0.29 M-103 , B-454, B-452,                                                Embedded                          Fire Sump, North-most T153    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB  8 pipe on West Wall            8    0.322    7.356  450.00  0.00      0    560.00    557.00    866.61  132.81 137.16  80.51  3.76 M-103 , B-454, B-452,                                                Embedded                          Fire Sump, West-most T154    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB  8 pipe on North Wall            8    0.322    7.356  450.00  0.00      0    560.00    557.00    866.61  132.81 137.16  80.51  3.76 M-103 , B-454, B-452,                                                Embedded                          Fire Sump, West-most T155    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB  10 pipe on North Wall          10    0.365    9.27  80.00  0.00      0    560.00    557.00    194.15    37.50  24.38  18.04  1.06 M-103 , B-454, B-452,                                                Embedded                          Fire Sump, East-most T156    B-471, B-473            0        Aerated Drain      Bld Pen        Pipe      Class 3  TB    TB  10 pipe on North Wall          10    0.365    9.27  100.00  0.00      0    560.00    557.00    242.69    46.87  30.48  22.55  1.33 Embedded              Main          Unit 1 Main Steam M001      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  45.34    U        32    569.54    569.00    47.79    4.01  13.82  4.44  0.11 Embedded              Main          Unit 1 Main Steam M002      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  40.67    U        34    569.96    567.25    42.86    3.60  12.40  3.98  0.10 Embedded              Main          Unit 1 Main Steam M003      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  93.23    R        34    569.54    569.00    98.27    8.24  28.42  9.13  0.23 Embedded              Main          Unit 1 Main Steam M004      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  84.11    R        34    569.54    569.00    88.66    7.44  25.64  8.24  0.21 Embedded              Main          Unit 1 Main Steam M005      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  34.25    G        34    569.96    566.17    36.10    3.03  10.44  3.35  0.09 Embedded              Main          Unit 1 Main Steam M006      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  11.72    J      34    569.54    569.00    12.35    1.04  3.57  1.15  0.03 Embedded              Main          Unit 1 Main Steam M007      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  67.33    J      33    569.96    566.08    70.97    5.95  20.52  6.59  0.17 Embedded              Main          Unit 1 Main Steam M009      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  8.96      J      32    569.54    569.00      9.45    0.79  2.73  0.88  0.02 Embedded              Main          Unit 1 Main Steam M010      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  45.42    J      31    569.96    568.79    47.87    4.02  13.84  4.45  0.11 Embedded              Main          Unit 1 Main Steam M011      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  16.96    J      30    569.54    569.00    17.87    1.50  5.17  1.66  0.04 Embedded              Main          Unit 1 Main Steam M012      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  Stm    TT  Tunnel Aerated Drain            4.5    0.237    4.026  30.79    J      30    569.54    569.00    32.45    2.72  9.39  3.02  0.08 Embedded                          Unit 1 Buttress Pit to M013      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT      Tunnel Sump                4.5    0.237    4.026  30.30    R        33    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                          Unit 1 Buttress Pit to M014      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT      Tunnel Sump                4.5    0.237    4.026  30.30    R        33    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                          Unit 1 Buttress Pit to M015      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT      Tunnel Sump                4.5    0.237    4.026  30.30    L        31    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                          Unit 1 Buttress Pit to M016      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT      Tunnel Sump                4.5    0.237    4.026  30.30    L        28    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                          Unit 1 Buttress Pit to M017      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT      Tunnel Sump                4.5    0.237    4.026  30.30    R        28    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                          Unit 1 Tendon Tunnel M018      B466, B467              0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT    TT        Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06  0.002 Page 93 of 123
Attachment F                                                                                        TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                            MARSSIM                                      Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No. Drawings    Line Ident No. System          Category      End Sate    Class  From  To      Description        inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2    ft3 meters  m2    m3 Embedded                        Unit 1 Tendon Tunnel M019  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 1 Tendon Tunnel M020  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 1 Tendon Tunnel M021  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 1 Tendon Tunnel M022  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 1 Tendon Tunnel M023  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        28    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 1 Tendon Tunnel M024  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT  Embedded Center Pipe            4.5    0.237    4.026  359.97    R        28    547.92    547.92    379.41  31.82 109.72 35.25  0.90 Embedded                        Unit 1 Clean Out In M025  B466, B467          0        U1 Aerated Drain  U1 Bld Pen      Pipe      Class 3  TT  TT      Front of Sump                4.5    0.237    4.026  9.75    R        28    547.54    547.50    10.28    0.86  2.97  0.95  0.02 Embedded              Main        Unit 2 Main Steam M201  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  45.49    U        8    569.54    568.85    47.95    4.02  13.87  4.45  0.11 Embedded              Main        Unit 2 Main Steam M202  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  39.50    U        6    569.96    568.42    41.63    3.49  12.04  3.87  0.10 Embedded              Main        Unit 2 Main Steam M203  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  92.86    R        6    569.54    568.85    97.87    8.21  28.30  9.09  0.23 Embedded              Main        Unit 2 Main Steam M204  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  82.86    R        6    569.54    568.83    87.33    7.32  25.25  8.11  0.21 Embedded              Main        Unit 2 Main Steam M205  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  34.04    G        6    569.96    566.38    35.88    3.01  10.38  3.33  0.09 Embedded              Main        Unit 2 Main Steam M206  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  11.95    J        6    569.54    568.88    12.59    1.06  3.64  1.17  0.03 Embedded              Main        Unit 2 Main Steam M207  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  66.81    J        7    569.96    566.10    70.42    5.91  20.36  6.54  0.17 Embedded              Main        Unit 2 Main Steam M209  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  8.95    J        8    569.54    568.88      9.43    0.79  2.73  0.88  0.02 Embedded              Main        Unit 2 Main Steam M210  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  43.47    J        9    569.96    568.80    45.81    3.84  13.25  4.26  0.11 Embedded              Main        Unit 2 Main Steam M211  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  17.02    J        10    569.54    568.94    17.94    1.50  5.19  1.67  0.04 Embedded              Main        Unit 2 Main Steam M212  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  Stm  TT  Tunnel Aerated Drain            4.5    0.237    4.026  30.85    J        10    569.54    568.94    32.52    2.73  9.40  3.02  0.08 Embedded                        Unit 2 Buttress Pit to M213  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Tunnel Sump                  4.5    0.237    4.026  30.30    R        7    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                        Unit 2 Buttress Pit to M214  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Tunnel Sump                  4.5    0.237    4.026  30.30    R        7    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                        Unit 2 Buttress Pit to M215  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Tunnel Sump                  4.5    0.237    4.026  30.30    L        9    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                        Unit 2 Buttress Pit to M216  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Tunnel Sump                  4.5    0.237    4.026  30.30    L        6    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                        Unit 2 Buttress Pit to M217  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Tunnel Sump                  4.5    0.237    4.026  30.30    R        6    564.18    547.75    31.94    2.68  9.24  2.97  0.08 Embedded                        Unit 2 Tendon Tunnel M218  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M219  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M220  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M221  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M222  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M223  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Floor Drain                4.5    0.237    4.026  0.63    R        6    548.54    547.92      0.66    0.06  0.19  0.06 0.002 Embedded                        Unit 2 Tendon Tunnel M224  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT  Embedded Center Pipe            4.5    0.237    4.026  359.97    R        6    547.92    547.92    379.41  31.82 109.72 35.25  0.90 Embedded                        Unit 2 Clean Out In M225  B481, B484          0        U2 Aerated Drain  U2 Bld Pen      Pipe      Class 3  TT  TT      Front of Sump                4.5    0.237    4.026  9.75    R        6    547.54    547.50    10.28    0.86  2.97  0.95  0.02 Force Main from W001 B-1003, B-1005                Aerated Drain  Bld to Yard Pen Pipe in Pen  Class 3 WWTF  WWTF  Turbine Fire Sump            8.625  0.322    7.981  1.00    D        2    586.67    586.67      2.09    0.35  0.30  0.19  0.01 Page 94 of 123
Attachment F                                                                                      TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas                                                          Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                            MARSSIM                                    Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area    Volume Length SA  Space No. Drawings    Line Ident No. System        Category      End Sate    Class  From  To      Description      inches inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters m2    m3 Heater bay roof drain W002 B-1003, B-1005                Aerated Drain  Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF          lines                6.625    0.28    6.065  1.00    D        2      585.20    585.20    1.59    0.20  0.30  0.15  0.01 Sludge Line from W003 B-1003, B-1005                  Sludge Line  Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF  Outdoor Drying Beds            3.5    0.216    3.068  1.00    A        6      587.00    587.00    0.80    0.05  0.30  0.07  0.001 Sludge drying bed W004 B-1003, B-1005                Waste Discharge Bld to Yard Pen Pipe in Pen  Class 3 WWTH WWTF        filtrate              6.625    0.28    6.065  1.00    A        4      588.00    588.00    1.59    0.20  0.30  0.15  0.01 W005 B-1003, B-1005                  Water Line    Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF Water Line from Yard          2.375  0.154    2.067  1.00    A        3      588.00    588.00    0.54    0.02  0.30  0.05  0.001 Cement Wrapped W006 B-1003, B-1005                Waste Discharge Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF      Ductile Pipe              8.625  0.322    7.981  1.00    A        2      586.75    586.75    2.09    0.35  0.30  0.19  0.01 W007 B-1003, B-1005                    Sanitary    Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF    Sanitary Line              1.9    0.145    1.61  1.00    A        2      587.00    587.00    0.42    0.01  0.30  0.04 0.0004 W008 B-1003, B-1005                  Service Air  Bld to Yard Pen Pipe in Pen  Class 3 WWTF WWTF    Service Air Line            1.9    0.145    1.61  1.00    A        2      586.75    586.75    0.42    0.01  0.30  0.04 0.0004 Page 95 of 123
Attachment G                                                                                                        TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List                                                                                  Revision 00 Y or    X or Unit 1  Unit 2                        Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                        Surface  Space        Int  Void Pen                  U1 Line Ident                                                MARSSIM                                                      Size    OD      Wall  Pipe ID Length Degrees  Degrees                End      Area  Volume Length  SA  Space No. Drawings            No.          System      Category          End Sate    Class    From      To                Description          inches inches Thickness  inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 P001 M-281, M-661    1-FP-037-4"    Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3 U1 CTMT    Aux              Fire Protection          10    4.5    0.237    4.026  4.83    107    253      577.5      577.5    12.65    2.64  1.47  1.18  0.075 P002 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare                6      0        0        0  4.83    98-30  261-30  588.83      588.83    7.59    0.95  1.47  0.71  0.027 P003 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare                6      0        0        0  4.83    98-15  263-45  577.50      577.50    7.59    0.95  1.47  0.71  0.027 P004 M-281, M-661    1-S1-090-3"  Safety Injection  Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux    Boron Injection Tank to Cold Legs    8    3.5    0.438    2.624  4.83      94    266    577.50      577.50    10.12    1.69  1.47  0.94  0.048 P005 M-281, M-661    1-MS-001-34"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Main Steam              50    34    1.15625  31.6875  4.00    213    147    579.50      579.50    52.36  54.54  1.22  4.86  1.544 P006 M-281, M-661    1-MS-002-34"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Main Steam              50    34    1.15625  31.6875  4.00    213    147    579.50      579.50    52.36  54.54  1.22  4.86  1.544 1-MS-003-35 P007 M-281, M-661          1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Main Steam              50    35.5    1.1875  33.125  4.00    333      27    579.50      579.50    52.36  54.54  1.22  4.86  1.544 1-MS-004-35 P008 M-281, M-661          1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Main Steam              50    35.5    1.1875  33.125  4.00    333      27    579.50      579.50    52.36  54.54  1.22  4.86  1.544 P009 M-281, M-661    1-FW-014-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Feedwater              32    16    1.218    13.564  4.00    213    147    584.58      584.58    33.51  22.34  1.22  3.11  0.633 P010 M-281, M-661    1-FW-017-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Feedwater              32    16    1.218    13.564  4.00    213    147    584.58      584.58    33.51  22.34  1.22  3.11  0.633 P011 M-281, M-661    1-FW-011-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Feedwater              32    16    1.218    13.564  4.00    333      27    584.58      584.58    33.51  22.34  1.22  3.11  0.633 P012 M-281, M-661    1-FW-022-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT              Feedwater              32    16    1.218    13.564  4.00    333      27    586.83      586.83    33.51  22.34  1.22  3.11  0.633 Residual Heat                                                            Reactor Coolant No. 1 Loop to P017 M-281, M-661    1-RH-015-14"      Removal      Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux      Residual Heat Removal Pumps      28    14    0.438    13.124  4.83    107    253    584.25      584.25    35.43  20.67  1.47  3.29  0.585 P018 M-281, M-661    1-CF-004-10"      Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux      Cavity Fill Pump 1A Discharge    18    10.75  0.365    10.02  4.83  102-45  257-15  584.25      584.25    22.78    8.54  1.47  2.12  0.242 Component Cooling Water Supply P019 M-281, M-661    1-CC-091-6"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux              Header to RCPs            12    6.625    0.28    6.065  4.83    107    253    586.83      586.83    15.18    3.80  1.47  1.41  0.107 P020 M-281, M-661    1-CF-003-10"      Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux      Cavity Fill Pump 1B Discharge    18    10.75  0.365    10.02  4.83  100-45  259-15  584.25      584.25    22.78    8.54  1.47  2.12  0.242 P021 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare              28      0        0        0  4.83    98-30  261-30  584.25      584.25    35.43  20.67  1.47  3.29  0.585 Residula Heat                                                          Residual Heat Exchanger to RC Loop P022 M-281, M-661    1-RH-006-12"      Removal      Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux                Cold Legs              28    12.75  0.406    11.938  4.83    98-30  261-30  580.08      580.08    35.43  20.67  1.47  3.29  0.585 RC Pumps to Comp Cooling Pump P023 M-281, M-661    1-CC-106-6"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Suction              12    6.625    0.28    6.065  4.83  100-45  259-15  586.83      586.83    15.18    3.80  1.47  1.41  0.107 Safety Inj Pumps to RC Loop Hot P024 M-281, M-661      1-SI-104-4"  Safety Injection  Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux                    Leg                14    4.5    0.438    3.624  4.83    107    253    588.83      588.83    17.72    5.17  1.47  1.65  0.146 RC Pumps to Comp Cooling Pump P033 M-281, M-661    1-CC-104-3"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Suction              12    3.5    0.216    3.068  4.83  102-45'  257-15  588.83      588.83    15.18    3.80  1.47  1.41  0.107 P034 M-281, M-661    1-DW-006-2"      Demin Water    Bld to Bld Pen  Open Sleeve  Class 3 U1 CTMT    Aux                Demin Water            12    2.375  0.154    2.067  4.83    96-15'  263-45  588.83      588.83    15.18    3.80  1.47  1.41  0.107 B-278, M-7, B-                                                    Pipe in P035  223, M-170,    1SI-008-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    Aux        Recirculating Sump Suction      24    20    0.594    18.812  51.17    135    225    561.25      561.25    251.99  98.76  15.60 23.41 2.797 B-278, M-7, B-                                                    Pipe in P036  223, M-170,    1CF-002-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    Aux        Cavity Flood Sump Suction      24    20    0.594    18.812  50.75    135    225    561.25      561.25    249.94  97.96  15.47 23.22 2.774 B-278, M-7, B-                                                    Pipe in P037  223, M-170,    1CF-001-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    Aux        Cavity Flood Sump Suction      24    20    0.594    18.812  50.83    135    225    561.25      561.25    250.35  98.12  15.49 23.26 2.778 1-WO-95-1                                                                            CTMT Sump Pump Dischage to Aux P042 M-281, M-661          1/2"      Rad Discharge    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux      Bld Flr Drain Analysis Tank      6    1.9    0.145      1.61  4.83  104-45  255-15  577.50      577.50    7.59    0.95  1.47  0.71  0.027 RC Drain Pump Discharge to Hold-P043 M-281, M-661    1-DT-036-3"    Rad Discharge    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux                  Up Tank                8    3.5    0.216    3.068  4.83    107    253    580.08      580.08    10.12    1.69  1.47  0.94  0.048 M-281, B-213                                                      Pipe in P049 Detail 4, M-661        0            Cavity      Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    SFB            Fuel Transfer Tube          24    24    0.688    22.624  8.21      90    270    578.54      578.54    48.62  22.92  2.50  4.52  0.649 P050 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare              10      0        0        0  4.83    96-15'  263-45  580.08      580.08    12.65    2.64  1.47  1.18  0.075 Containment P054 M-281, M-661    1-CS-063-2"      Pressure      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux          Containment Pressure          6    2.375  0.154    2.067  4.83  109-15'  250-45  586.83      586.83    7.59    0.95  1.47  0.71  0.027 P056 M-281, M-661    1-VF-132-2"    Filtered Vents  Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux              Filtered Vents            8    2.375  0.154    2.067  4.83  100-45'  250-15  580.08      580.08    10.12    1.69  1.47  0.94  0.048 P064 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare              10      0        0        0  4.83      94    266    586.83      586.83    12.65    2.64  1.47  1.18  0.075 1-VC-033,043, P066 M-281, M-661    052E, 085-2"    Seal Water    Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux    RC Pump Seal Water Supply Lines    14    14    0.437    13.126  4.83  102-45'  257-15  580.08      580.08    17.72    5.17  1.47  1.65  0.146 P067 M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                    Spare              18      0        0        0  4.83  108-15'  249-45  584.25      584.25    22.78    8.54  1.47  2.12  0.242 P068 M-281, M-661    1-FW-018-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux    Aux Feedwater to Steam Gen 1C      14    3.5    0.438    2.624  4.83  100-45'  259-15  577.50      577.50    17.72    5.17  1.47  1.65  0.146 Page 96 of 123
Attachment G                                                                                                            TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List                                                                                      Revision 00 Y or    X or Unit 1  Unit 2                        Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                        Surface  Space        Int  Void Pen                U1 Line Ident                                                MARSSIM                                                          Size    OD    Wall    Pipe ID Length Degrees  Degrees                End      Area  Volume Length  SA  Space No. Drawings          No.        System        Category          End Sate    Class    From      To                Description              inches inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 P069 M-281, M-661  1-FW-015-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux      Aux Feedwater to Steam Gen 1A        14    3.5    0.438    2.624  4.83  109-15'  250-45  577.50      577.50    17.72    5.17  1.47  1.65  0.146 Refueling Cavity Drain to Purification P070 M-281, M-661    1-DT-032-3"    Cavity Drain    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux              Pump Suction                14    3.5    0.216    3.068  4.83  102-45'  257-15  577.50      577.50    17.72    5.17  1.47  1.65  0.146 1-BD-001-2 P071 M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux        Steam Generator Blowdown            14    2.875  0.276    2.323  4.83  104-45'  255-15  588.83      588.83    17.72    5.17  1.47  1.65  0.146 P073 M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    18      0      0        0    4.83  104-45'  255-15  584.25      584.25    22.78    8.54  1.47  2.12  0.242 P074 M-281, M-661  1-FW-012-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux      Aux Feedwater to Steam Gen 1D        14    3.5    0.438    2.624  4.83  104-45'  255-15  586.83      586.83    17.72    5.17  1.47  1.65  0.146 P076 M-282, M-662  1-SS-026-3/8"  Sample Line      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux        Accumulator Tank Sample            14    0.675  0.065    0.545  4.83  109-15'  250-45  588.83      588.83    17.72    5.17  1.47  1.65  0.146 P081 M-281, M-661  1-VN-008-2"  Vent Non-filtered  Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux            Non-Filtered Vents              8    2.375  0.154    2.067  4.83  109-15'  250-45  580.08      580.08    10.12    1.69  1.47  0.94  0.048 P084 M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    10      0      0        0    4.83      94    266    588.83      588.83    12.65    2.64  1.47  1.18  0.075 P085 M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    10      0      0        0    4.83  100-45'  259-45  588.83      588.83    12.65    2.64  1.47  1.18  0.075 1-SS-001,2,3-                                                                            Press Stem, Press Liq, RC Hot Leg P086 M-282, M-661        3/8"      Sample Line      Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Samples                  10    0.675  0.065    0.545  4.83  102-45'  257-15  586.83      586.83    12.65    2.64  1.47  1.18  0.075 P087 M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    10      0      0        0    4.83    96-15'  263-45  584.25      584.25    12.65    2.64  1.47  1.18  0.075 P088 M-281, M-661    1-HS-030-2"      Heating        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux    Heating System Hot Water Supply        12    2.375  0.218    1.939  4.83    98-30'  261-30  586.83      586.83    15.18    3.80  1.47  1.41  0.107 P089 M-281, M-661    0-HS-053-2"      Heating        Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux    Heating System Hot Water Return        12    2.375  0.218    1.939  4.83    96-15'  263-45  586.83      586.83    15.18    3.80  1.47  1.41  0.107 P090 M-282, M-662      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    28      0      0        0    4.83      94    266    584.25      584.25    35.43  20.67  1.47  3.29  0.585 1-BD-007-2 P091 M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1A          16    2.875  0.276    2.323  4.00    213    147    584.58      584.58    16.76    5.59  1.22  1.56  0.158 P092 M-281, M-661    1-BD-008-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1A          16    2.375  0.218    1.939  4.00    213    147    584.58      584.58    16.76    5.59  1.22  1.56  0.158 P093 M-281, M-661    1-BD-006-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1C          16    2.375  0.218    1.939  4.00    213    147    584.58      584.58    16.76    5.59  1.22  1.56  0.158 1-BD-005-2 P094 M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1C          16    2.875  0.276    2.323  4.00    213    147    584.58      584.58    16.76    5.59  1.22  1.56  0.158 P095 M-281, M-661    1-BD-007-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1A          14    2.375  0.218    1.939  4.00    213    147    580.33      580.33    14.66    4.28  1.22  1.36  0.121 P096 M-281, M-661    1-BD-005-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1C          14    2.375  0.218    1.939  4.00    213    147    580.33      580.33    14.66    4.28  1.22  1.36  0.121 P097 M-281, M-661    1-BD-003-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1D          14    2.375  0.218    1.939  4.00    333      27    580.33      580.33    14.66    4.28  1.22  1.36  0.121 P098 M-281, M-661    1-BD-001-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown Steam Generator 1B          14    2.375  0.218    1.939  4.00    333      27    580.33      580.33    14.66    4.28  1.22  1.36  0.121 P103 M-282, M-662      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U1 CTMT    Aux                  Spare                    8      0      0        0    4.83    98-30'  261-30  577.50      577.50    10.12    1.69  1.47  0.94  0.048 P104 M-282, M-662  1-MS-018-6"  Reactor Coolant    Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux          SIM to Aux F.S. Pumps            24    6.625  0.432    5.761  4.83      94    266    580.08      580.08    30.37  15.18  1.47  2.82  0.430 Residula Heat                                                          Residual Heat Exchanger to RC Loop P105 M-282, M-662    1-SI-011-10"    Removal        Bld to Bld Pen  Open Sleeve  Class 1 U1 CTMT    Aux                Hot Legs                  18    10.75  1.125    8.5    4.83  104-45  255-15  580.08      580.08    22.78    8.54  1.47  2.12  0.242 P112 M-282, M-662  1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT  Steam Generator Blowdown Sample        16    0.675  0.065    0.545  4.00    213    147    578.08      578.08    16.76    5.59  1.22  1.56  0.158 P113 M-282, M-662  1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT  Steam Generator Blowdown Sample        16    0.675  0.065    0.545  4.00    333      27    578.08      578.08    16.76    5.59  1.22  1.56  0.158 1-BD-003-2 P115 M-282, M-662        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT  Blowdown (Steam Generator 1D)          16    2.875  0.276    2.323  4.00    333      27    584.58      584.58    16.76    5.59  1.22  1.56  0.158 P116 M-282, M-662    1-BD-004-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT  Blowdown (Steam Generator 1D)          16    2.375  0.218    1.939  4.00    333      27    584.58      584.58    16.76    5.59  1.22  1.56  0.158 P117 M-282, M-662    1-BD-002-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown (Steam Generator 1B)        16    2.375  0.218    1.939  4.00    333      27    584.58      584.58    16.76    5.59  1.22  1.56  0.158 1-BD-001-2 P118 M-282, M-662        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT    Blowdown (Steam Generator 1B)        16    2.875  0.276    2.323  4.00    333      27    584.58      584.58    16.76    5.59  1.22  1.56  0.158 B-278, M-7, B-                                                    Pipe in P123  223, M-170,    1SI-007-20"      Drain        Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    Aux        Recirculating Sump Suction          24    20    0.594  18.812  52.00    135    225    561.25      561.25    256.10  100.37  15.85 23.79 2.842 B-278, M-7, B-                                                    Pipe in P124  223, M-170,    1SI-009-20"      Drain        Bld to Bld Pen    Sleeve    Class 1 U1 CTMT    Aux        Recirculating Sump Suction          24    20    0.594  18.812  52.83    135    225    561.25      561.25    260.20  101.98  16.10 24.17 2.888 P127 M-282, M-662  1-MS-018-6"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT      Steam to Aux FW Pumps              16    6.625  0.432    5.761  4.00    213    147    578.08      578.08    16.76    5.59  1.22  1.56  0.158 P128 M-282, M-662  1-MS-017-6"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U1 CTMT      Steam to Aux FW Pumps              16    6.625  0.432    5.761  4.00    333      27    578.08      578.08    16.76    5.59  1.22  1.56  0.158 Page 97 of 123
Attachment G                                                                                                        TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List                                                                                  Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void U1 Line Ident                                                MARSSIM                                                        Size    OD      Wall  Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space Peno. Drawings            No.          System      Category          End Sate    Class    From      To                Description          inches inches Thickness  inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 P201  M-281, M-661    2-FP-037-4"    Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3 U2 CTMT    Aux              Fire Protection          10    4.5    0.237    4.026  4.83    107    253    577.50    577.50    12.65    2.64  1.47  1.18  0.075 P202  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare                6      0        0        0  4.83    98-30  261-30  588.83    588.83    7.59    0.95  1.47  0.71  0.027 P203  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare                6      0        0        0  4.83    98-15  263-45  577.50    577.50    7.59    0.95  1.47  0.71  0.027 P204  M-281, M-661    2-S1-090-3"  Safety Injection  Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux    Boron Injection Tank to Cold Legs    8    3.5    0.438    2.624  4.83      94    266    577.50    577.50    10.12    1.69  1.47  0.94  0.048 P205  M-281, M-661    2-MS-001-34"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT              Main Steam              50    34    1.15625  31.6875  4.00    213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.544 P206  M-281, M-661    2-MS-002-34"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT              Main Steam              50    34    1.15625  31.6875  4.00    213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.544 2-MS-003-35 P207  M-281, M-661          1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT              Main Steam              50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.544 2-MS-004-35 P208  M-281, M-661          1/2"      Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT              Main Steam              50    35.5    1.1875  33.125  4.00    333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.544 P209  M-281, M-661    2-FW-014-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT                Feedwater              32    16    1.218    13.564  4.00    213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 P210  M-281, M-661    2-FW-017-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT                Feedwater              32    16    1.218    13.564  4.00    213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 P211  M-281, M-661    2-FW-011-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT                Feedwater              32    16    1.218    13.564  4.00    333      27    584.58    584.58    33.51  22.34  1.22  3.11  0.633 P212  M-281, M-661    2-FW-022-16"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT                Feedwater              32    16    1.218    13.564  4.00    333      27    586.83    586.83    33.51  22.34  1.22  3.11  0.633 Residula Heat                                                            Reactor Coolant No. 1 Loop to P217  M-281, M-661    2-RH-015-14"      Removal      Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux      Residual Heat Removal Pumps        28    14    0.438    13.124  4.83    107    253    584.25    584.25    35.43  20.67  1.47  3.29  0.585 P218  M-281, M-661    2-CF-004-10"      Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux      Cavity Fill Pump 1A Discharge      18    10.75  0.365    10.02  4.83  102-45  257-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 Component Cooling Water Supply P219  M-281, M-661    2-CC-091-6"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux              Header to RCPs            12    6.625    0.28    6.065  4.83    107    253    586.83    586.83    15.18    3.80  1.47  1.41  0.107 P220  M-281, M-661    2-CF-003-10"      Cavity Fill    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux      Cavity Fill Pump 1B Discharge      18    10.75  0.365    10.02  4.83  100-45  259-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 P221  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare              28      0        0        0  4.83    98-30  261-30  584.25    584.25    35.43  20.67  1.47  3.29  0.585 Residula Heat                                                          Residual Heat Exchanger to RC Loop P222  M-281, M-661    2-RH-006-12"      Removal      Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux                  Cold Legs              28    12.75  0.406    11.938  4.83    98-30  261-30  580.08    580.08    35.43  20.67  1.47  3.29  0.585 RC Pumps to Comp Cooling Pump P223  M-281, M-661    2-CC-106-6"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Suction              12    6.625    0.28    6.065  4.83  100-45  259-15  586.83    586.83    15.18    3.80  1.47  1.41  0.107 P224  M-281, M-661      2-SI-104-4"  Safety Injection  Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux  Safety Inj Pumps to RC Loop Hot Leg  14    4.5    0.438    3.624  4.83    107    253    588.83    588.83    17.72    5.17  1.47  1.65  0.146 RC Pumps to Comp Cooling Pump P233  M-281, M-661    2-CC-104-3"  Component Cooling  Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Suction              12    3.5    0.216    3.068  4.83  102-45'  257-15  588.83    588.83    15.18    3.80  1.47  1.41  0.107 P234  M-281, M-661    2-DW-006-2"      Demin Water    Bld to Bld Pen  Open Sleeve  Class 3 U2 CTMT    Aux                Demin Water              12    2.375  0.154    2.067  4.83    96-15'  263-45  588.83    588.83    15.18    3.80  1.47  1.41  0.107 B-278, M-7, B-                                                    Pipe in P235  223, M-170,    2SI-008-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    Aux        Recirculating Sump Suction      24    20    0.594    18.812  51.17    135    225    561.25    561.25    251.99  98.76  15.60 23.41 2.797 B-278, M-7, B-                                                    Pipe in P236  223, M-170,    2CF-002-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    Aux        Cavity Flood Sump Suction        24    20    0.594    18.812  50.75    135    225    561.25    561.25    249.94  97.96  15.47 23.22 2.774 B-278, M-7, B-                                                    Pipe in P237  223, M-170,    2CF-001-20"        Drain      Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    Aux        Cavity Flood Sump Suction        24    20    0.594    18.812  50.83    135    225    561.25    561.25    250.35  98.12  15.49 23.26 2.778 2-WO-95-1                                                                            CTMT Sump Pump Dischage to Aux P242  M-281, M-661          1/2"      Rad Discharge    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux        Bld Flr Drain Analysis Tank      6    1.9    0.145      1.61  4.83  104-45  255-15  577.50    577.50    7.59    0.95  1.47  0.71  0.027 RC Drain Pump Discharge to Hold-P243  M-281, M-661    2-DT-036-3"    Rad Discharge    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux                  Up Tank                8    3.5    0.216    3.068  4.83    107    253    580.08    580.08    10.12    1.69  1.47  0.94  0.048 M-281, B-213                                                      Pipe in P249  Detail 4, M-661        0            Cavity      Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    SFB            Fuel Transfer Tube          24    24    0.688    22.624  8.21      90    270    578.54    578.54    48.62  22.92  2.50  4.52  0.649 P250  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare              10      0        0        0  4.83    96-15'  263-45  580.08    580.08    12.65    2.64  1.47  1.18  0.075 Containment P254  M-281, M-661    2-CS-063-2"      Pressure      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux          Containment Pressure          6    2.375  0.154    2.067  4.83  109-15'  250-45  586.83    586.83    7.59    0.95  1.47  0.71  0.027 P256  M-281, M-661    2-VF-132-2"    Filtered Vents  Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                Filtered Vents            8    2.375  0.154    2.067  4.83  100-45'  250-15  580.08    580.08    10.12    1.69  1.47  0.94  0.048 P264  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare              10      0        0        0  4.83      94    266    586.83    586.83    12.65    2.64  1.47  1.18  0.075 2-VC-033,043, P266  M-281, M-661    052E, 085-2"    Seal Water    Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux    RC Pump Seal Water Supply Lines      14    2.375  0.344    1.687  4.83  102-45'  257-15  580.08    580.08    17.72    5.17  1.47  1.65  0.146 P267  M-281, M-661        Spare            N/A        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                    Spare              18      0        0        0  4.83  108-15'  249-45  584.25    584.25    22.78    8.54  1.47  2.12  0.242 P268  M-281, M-661    2-FW-018-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux    Aux Feedwater to Steam Gen 1C      14    3.5    0.438    2.624  4.83  100-45'  259-15  577.50    577.50    17.72    5.17  1.47  1.65  0.146 Page 98 of 123
Attachment G                                                                                                          TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List                                                                                      Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Sleeve  Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void U1 Line Ident                                                MARSSIM                                                          Size    OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space Peno. Drawings          No.        System        Category          End Sate    Class    From      To                Description              inches inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 P269  M-281, M-661  2-FW-015-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux      Aux Feedwater to Steam Gen 1A        14    3.5    0.438    2.624  4.83  109-15'  250-45  577.50    577.50    17.72    5.17  1.47  1.65  0.146 Refueling Cavity Drain to Purification P270  M-281, M-661    2-DT-032-3"    Cavity Drain    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux              Pump Suction                14    3.5    0.216    3.068  4.83  102-45'  257-15  577.50    577.50    17.72    5.17  1.47  1.65  0.146 2-BD-001-2 P271  M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux        Steam Generator Blowdown            14    2.875  0.276    2.323  4.83  104-45'  255-15  588.83    588.83    17.72    5.17  1.47  1.65  0.146 P273  M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    18      0      0        0    4.83  104-45'  255-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 P274  M-281, M-661  2-FW-012-3"      Feedwater      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux      Aux Feedwater to Steam Gen 1D        14    3.5    0.438    2.624  4.83  104-45'  255-15  586.83    586.83    17.72    5.17  1.47  1.65  0.146 P276  M-282, M-662  2-SS-026-3/8"  Sample Line      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux        Accumulator Tank Sample            14    0.675  0.065    0.545  4.83  109-15'  250-45  588.83    588.83    17.72    5.17  1.47  1.65  0.146 P281  M-281, M-661  2-VN-008-2"  Vent Non-filtered  Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux            Non-Filtered Vents              8    2.375  0.154    2.067  4.83  109-15'  250-45  580.08    580.08    10.12    1.69  1.47  0.94  0.048 P284  M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    10      0      0        0    4.83      94    266    588.83    588.83    12.65    2.64  1.47  1.18  0.075 P285  M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    10      0      0        0    4.83  100-45'  259-45  588.83    588.83    12.65    2.64  1.47  1.18  0.075 2-SS-001,2,3-                                                                            Press Stem, Press Liq, RC Hot Leg P286  M-282, M-661        3/8"      Sample Line      Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Samples                  10    0.675  0.065    0.545  4.83  102-45'  257-15  586.83    586.83    12.65    2.64  1.47  1.18  0.075 P287  M-281, M-661      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    10      0      0        0    4.83    96-15'  263-45  584.25    584.25    12.65    2.64  1.47  1.18  0.075 P288  M-281, M-661    2-HS-030-2"      Heating        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux    Heating System Hot Water Supply        12    2.375  0.218    1.939  4.83    98-30'  261-30  586.83    586.83    15.18    3.80  1.47  1.41  0.107 P289  M-281, M-661    0-HS-053-2"      Heating        Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux    Heating System Hot Water Return        12    2.375  0.218    1.939  4.83    96-15'  263-45  586.83    586.83    15.18    3.80  1.47  1.41  0.107 P290  M-282, M-662      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    28      0      0        0    4.83      94    266    584.25    584.25    35.43  20.67  1.47  3.29  0.585 2-BD-007-2 P291  M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1A          16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 P292  M-281, M-661    2-BD-008-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1A          16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 P293  M-281, M-661    2-BD-006-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1C          16    2.375  0.218    1.939  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 2-BD-005-2 P294  M-281, M-661        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1C          16    2.875  0.276    2.323  4.00    213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 P295  M-281, M-661    2-BD-007-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1A          14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.121 P296  M-281, M-661    2-BD-005-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1C          14    2.375  0.218    1.939  4.00    213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.121 P297  M-281, M-661    2-BD-003-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1D          14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.121 P298  M-281, M-661    2-BD-001-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown Steam Generator 1B          14    2.375  0.218    1.939  4.00    333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.121 P303  M-282, M-662      Spare          N/A          Bld to Bld Pen  Open Sleeve  Class 2 U2 CTMT    Aux                  Spare                    8      0      0        0    4.83    98-30'  261-30  577.50    577.50    10.12    1.69  1.47  0.94  0.048 P304  M-282, M-662  2-MS-018-6"  Reactor Coolant    Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux          SIM to Aux F.S. Pumps            24    6.625  0.432    5.761  4.83      94    266    580.08    580.08    30.37  15.18  1.47  2.82  0.430 Residula Heat                                                          Residual Heat Exchanger to RC Loop P305  M-282, M-662    2-SI-011-10"    Removal        Bld to Bld Pen  Open Sleeve  Class 1 U2 CTMT    Aux                Hot Legs                  18    10.75  1.125    8.5    4.83  104-45  255-15  580.08    580.08    22.78    8.54  1.47  2.12  0.242 P312  M-282, M-662  2-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT  Steam Generator Blowdown Sample        16    0.675  0.065    0.545  4.00    213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.158 P313  M-282, M-662  2-SS-041-3/8"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT  Steam Generator Blowdown Sample        16    0.675  0.065    0.545  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.158 2-BD-003-2 P315  M-282, M-662        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT  Blowdown (Steam Generator 1D)          16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 P316  M-282, M-662    2-BD-004-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT  Blowdown (Steam Generator 1D)          16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 P317  M-282, M-662    2-BD-002-2"  SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown (Steam Generator 1B)        16    2.375  0.218    1.939  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 2-BD-001-2 P318  M-282, M-662        1/2"      SG Blowdown      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT    Blowdown (Steam Generator 1B)        16    2.875  0.276    2.323  4.00    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 B-278, M-7, B-                                                    Pipe in P323  223, M-170,    2SI-007-20"      Drain        Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    Aux        Recirculating Sump Suction          24    20    0.594  18.812  52.00    135    225    561.25    561.25    256.10  100.37  15.85 23.79 2.842 B-278, M-7, B-                                                    Pipe in P324  223, M-170,    2SI-009-20"      Drain        Bld to Bld Pen    Sleeve    Class 1 U2 CTMT    Aux        Recirculating Sump Suction          24    20    0.594  18.812  52.83    135    225    561.25    561.25    260.20  101.98  16.10 24.17 2.888 P327  M-282, M-662  2-MS-018-6"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT      Steam to Aux FW Pumps              16    6.625  0.432    5.761  4.00    213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.158 P328  M-282, M-662  2-MS-017-6"    Main Steam      Bld to Bld Pen  Open Sleeve  Class 2 Main Stm U2 CTMT      Steam to Aux FW Pumps              16    6.625  0.432    5.761  4.00    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.158 Page 99 of 123
Attachment G                                                                                          TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List                                                                      Revision 00 Incore Sump Inventory Void Sleeve                                                          Interior  Space Penetration                                            MARSSIM                                          Size  Pipe OD  Wall    Pipe ID  Length              End      Surface  Volume Length Int SA  Void No. Drawings System Category      End Sate    Class      From      To        Description  inches  inches Thickness inches    Feet  Elevation Elevation  Area ft2    ft3 meters  m2  Space m3 P125      B-234    Drain  Bld Pen    Embedded Pipe  Class 1    U1 CTMT U1 CTMT    Incore Sump Pipe  1.9    1.9    0.145    1.61  26.73908  542.5    542.5      11.27      0.53  8.15  1.05    0.015 P325      B-234    Drain  Bld Pen    Embedded Pipe  Class 1    U1 CTMT U1 CTMT    Incore Sump Pipe  1.9    1.9    0.145    1.61  26.73908  542.5    542.5      11.27      0.53  8.15  1.05    0.015 Page 100 of 123
Attachment H                                                                                                      TSD # 14-016 Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List                                                            Revision 00 Main Steam Tunnel Drains Y or Unit X or Unit Void      1        2                                    Void Pipe                            Space  Azimuth  Azimuth                      Interior  Space            Int  Void Pen                                                        MARSSIM                                                        OD    Wall    Pipe ID Length Volume  Degrees - Degrees -              End    Surface  Volume    Length  SA    Space No. Drawings      System        Category    End Sate    Class    From    To                Description              inches Thickness inches  Feet    in3  minutes  minutes  Elevation Elevation Area ft2    ft3    meters  m2    m3 M001 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  45.34 6925.92    U        32      569.54    569.00    47.79    4.01    13.82 4.44  0.113 M002 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  40.67 6212.37    U        34      569.96    567.25    42.86    3.60    12.40 3.98  0.102 M003 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  93.23 14242.42    R        34      569.54    569.00    98.27    8.24    28.42 9.13  0.233 M004 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  84.11 12849.55    R        34      569.54    569.00    88.66    7.44    25.64 8.24  0.211 M005 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  34.25 5232.14    G        34      569.96    566.17    36.10    3.03    10.44 3.35  0.086 M006 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  11.72 1789.66      J        34      569.54    569.00    12.35    1.04    3.57  1.15  0.029 M007 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  67.33 10286.05    J        33      569.96    566.08    70.97    5.95    20.52 6.59  0.169 M009 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  8.96  1369.41      J        32      569.54    569.00      9.45    0.79    2.73  0.88  0.022 M010 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  45.42 6938.07      J        31      569.96    568.79    47.87    4.02    13.84 4.45  0.114 M011 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  16.96 2590.61      J        30      569.54    569.00    17.87    1.50    5.17  1.66  0.042 M012 B466, B467 U1 Aerated Drain  U1 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 1 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  30.79 4703.83      J        30      569.54    569.00    32.45    2.72    9.39  3.02  0.077 M201 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  45.49 6949.51    U          8      569.54    568.85    47.95    4.02    13.87 4.45  0.114 M202 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  39.50 6034.15    U          6      569.96    568.42    41.63    3.49    12.04 3.87  0.099 M203 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  92.86 14185.06    R          6      569.54    568.85    97.87    8.21    28.30 9.09  0.232 M204 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  82.86 12657.42    R          6      569.54    568.83    87.33    7.32    25.25 8.11  0.207 M205 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  34.04 5200.31    G          6      569.96    566.38    35.88    3.01    10.38 3.33  0.085 M206 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  11.95 1824.76      J        6      569.54    568.88    12.59    1.06    3.64  1.17  0.030 M207 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  66.81 10206.49    J        7      569.96    566.10    70.42    5.91    20.36 6.54  0.167 M209 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  8.95  1366.75      J        8      569.54    568.88      9.43    0.79    2.73  0.88  0.022 M210 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  43.47 6639.88      J        9      569.96    568.80    45.81    3.84    13.25 4.26  0.109 M211 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  17.02 2600.16      J        10      569.54    568.94    17.94    1.50    5.19  1.67  0.043 M212 B481, B484 U2 Aerated Drain  U2 Bld Pen Embedded Pipe  Class 3 Main Stm TT  Unit 2 Main Steam Tunnel Aerated Drain  4.5    0.237    4.026  30.85 4713.38      J        10      569.54    568.94    32.52    2.73    9.40  3.02  0.077 Buttress Pit and Tendon Tunnel Drains Y or Unit X or Unit Void      1        2 Pipe                            Space  Azimuth  Azimuth                      Interior  Void            Int Pen                                                        MARSSIM                                                        OD      Wall  Pipe ID Length  Volume  Degrees - Degrees -            End    Surface    Space    Length SA    Void No. Drawings      System        Category    End Sate    Class    From    To                Description              inches Thickness  inches  Feet    in3    minutes  minutes  Elevation Elevation Area ft2 Volume ft3 meters m2  Space m3 M013 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R        33      564.18    547.75    31.94      2.68      9.24 2.97  0.08 M014 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R        33      564.18    547.75    31.94      2.68      9.24 2.97  0.08 M015 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    L        31      564.18    547.75    31.94      2.68      9.24 2.97  0.08 M016 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    L        28      564.18    547.75    31.94      2.68      9.24 2.97  0.08 M017 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R        28      564.18    547.75    31.94      2.68      9.24 2.97  0.08 M018 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026  0.63  95.48      R        28      548.54    547.92    0.66      0.06      0.19 0.06  0.00 M019 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026  0.63  95.48      R        28      548.54    547.92    0.66      0.06      0.19 0.06  0.00 M020 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026  0.63  95.48      R        28      548.54    547.92    0.66      0.06      0.19 0.06  0.00 M021 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026  0.63  95.48      R        28      548.54    547.92    0.66      0.06      0.19 0.06  0.00 M022 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3    TT    TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026  0.63  95.48      R        28      548.54    547.92    0.66      0.06      0.19 0.06  0.00 Page 101 of 123
Attachment H                                                                                                        TSD # 14-016 Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List                                                        Revision 00 Y or Unit X or Unit Void      1        2 Pipe                            Space  Azimuth  Azimuth                      Interior  Void            Int Pen                                                        MARSSIM                                                    OD    Wall    Pipe ID Length Volume  Degrees - Degrees -            End    Surface    Space    Length  SA    Void No. Drawings      System        Category    End Sate    Class  From To                Description              inches Thickness inches  Feet    in3  minutes  minutes  Elevation Elevation Area ft2 Volume ft3 meters  m2  Space m3 M023 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 1 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R        28      548.54    547.92    0.66      0.06    0.19  0.06    0.00 Unit 1 Tendon Tunnel Embedded Center M024 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3  TT  TT                    Pipe                    4.5    0.237    4.026  359.97 54990.79    R        28      547.92    547.92    379.41    31.82    109.72 35.25  0.90 M025 B466, B467 U2 Aerated Drain  U1 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 1 Clean Out In Front of Sump      4.5    0.237    4.026    9.75  1489.44    R        28      547.54    547.50    10.28    0.86    2.97  0.95    0.02 M213 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R          7      564.18    547.75    31.94    2.68    9.24  2.97    0.08 M214 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R          7      564.18    547.75    31.94    2.68    9.24  2.97    0.08 M215 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    L        9      564.18    547.75    31.94    2.68    9.24  2.97    0.08 M216 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    L        6      564.18    547.75    31.94    2.68    9.24  2.97    0.08 M217 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Buttress Pit to Tunnel Sump    4.5    0.237    4.026  30.30  4629.42    R          6      564.18    547.75    31.94    2.68    9.24  2.97    0.08 M218 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 M219 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 M220 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 M221 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 M222 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 M223 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Tendon Tunnel Floor Drain      4.5    0.237    4.026    0.63  95.48    R          6      548.54    547.92    0.66      0.06    0.19  0.06    0.00 Unit 2 Tendon Tunnel Embedded Center M224 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT                    Pipe                    4.5    0.237    4.026  359.97 54990.79    R          6      547.92    547.92    379.41    31.82    109.72 35.25  0.90 M225 B481, B484 U2 Aerated Drain  U2 Bld Pen  Embedded Pipe  Class 3  TT  TT    Unit 2 Clean Out In Front of Sump      4.5    0.237    4.026    9.75  1489.44    R          6      547.54    547.50    10.28    0.86    2.97  0.95    0.02 Page 102 of 123
Attachment I                                                                                                    TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                    Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                                  MARSSIM                                                          OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings              No.            System        Category        End Sate    Class      From    To                Description          inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 A001 M-162, M-172, M-185  OSW-014-24"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3      Aux    TB                Service Water            24    0.688  22.624    3      G        16      586        586      17.77    9.42  0.91  1.65  0.267 A002 M-162, M-172, M-185    2FW-027-4"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2      Aux    TB                  Feedwater              4.5    0.237    4.026    3      G        16    578.25    578.25    3.16    0.33  0.91  0.29  0.009 A003 M-162, M-172, M-185  OWS-011-2"    Secondary Sample    Bld to Bld Pen  Open Sleeve  Class 2      Aux    TB            Secondary Sample          2.375  0.154    2.067    3      G        16      586        586      1.62    0.09  0.91  0.15  0.003 A004    M-182, M-163      OSW-013-24"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Service Water            24    0.688  22.624    3      G        23      586        586      17.77    9.42  0.91  1.65  0.267 A005    M-182, M-163        1FW-027-4"        Feedwater      Bld to Bld Pen  Open Sleeve  Class 2      TB    Aux                Feedwater              4.5    0.237    4.026    3      G        23      588        588      3.16    0.33  0.91  0.29  0.009 A006    M-165, M-187      OFP-012-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3    Main Stm Aux              Fire Protection          10.75  0.365    10.02    3      H        10      571        571      7.87    1.89  0.91  0.73  0.054 A007 M-165, M-171, M-185    1VN-001-4"    Vents and Drains  Bld to Bld Pen  Open Sleeve  Class 2      TB    Aux        Aux Bld Vents & Drains        4.5    0.237    4.026    3      G        13    569.75    569.75    3.16    0.33  0.91  0.29  0.009 A008 M-165, M-171, M-185    2VN-001-4"    Vents and Drains  Bld to Bld Pen  Open Sleeve  Class 2      TB    Aux        Aux Bld Vents & Drains        4.5    0.237    4.026    3      G        13    568.75    568.75    3.16    0.33  0.91  0.29  0.009 A009 M-165, M-171, M-185  OWD-031-3      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1      Aux    TB              Waste Disposal            3.5    0.216    3.068    3      G        13    573.25    573.25    2.41    0.20  0.91  0.22  0.006 A010 M-165, M-171, M-185  OSW-056-10"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3      Aux    TB                Service Water          10.75  0.365    10.02    3      G        14    572.25    572.25    7.87    1.89  0.91  0.73  0.054 A011 M-162, M-172, M-185  OWD-039-2"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1      TB    Aux              Waste Disposal          2.375  0.154    2.067    3      G        17      574.5      574.5    1.62    0.09  0.91  0.15  0.003 A012    M-165, M-168        OCA-007-3"    Chemical Addition  Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Chemical Feed            3.5    0.216    3.068    3      G        17      565.5      565.5    2.41    0.20  0.91  0.22  0.006 A013    M-165, M-174      OPW-020-4"      Primary Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Primary Water            4.5    0.237    4.026    3      G        17    573.17    573.17    3.16    0.33  0.91  0.29  0.009 A014    M-165, M-174      2SW-002-20"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Service Water            20    0.594  18.812    3      G        17      570.5      570.5    14.77    6.54  0.91  1.37  0.185 A015 M-165, M-171, M-185  OWD-016-6"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1      Aux    TB              Waste Disposal          6.625    0.28    6.065    3      G        13      571        571      4.76    0.72  0.91  0.44  0.020 See Multiple CTMT to Aux Pens on M-Main    282 and M-662 cover in CTMT A016        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3      Aux    Stm                Worksheet              14    0.438  13.124    2      H        10      571        571      6.87    2.14  0.61  0.64  0.061 A017    M-182, M-163      OFP-003-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Fire Protection          10.75  0.365    10.02    3      G        23      586.5      586.5    7.87    1.89  0.91  0.73  0.054 A018    M-166, M-188      OFP-012-10"      Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3    Main Stm Aux              Fire Protection          10.75  0.365    10.02    3      H        30      571        571      7.87    1.89  0.91  0.73  0.054 A019    M-165, M-174      OPW-042-3"      Primary Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Primary Water            3.5    0.216    3.068    3      G        17    573.42    573.42    2.41    0.20  0.91  0.22  0.006 A020    M-182, M-166        OVC-071-3"    Vacuum Control    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux            Vacuum Control            3.5    0.216    3.068    3      G        24    576.25    576.25    2.41    0.20  0.91  0.22  0.006 A021    M-182,M-166        ODW-003-3"        Demin Water      Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux              Demin Water              3.5    0.216    3.068    3      G        24    568.75    568.75    2.41    0.20  0.91  0.22  0.006 A022    M-182, M-166      OPW-005-4"      Primary Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux            Line with Flange          4.5    0.237    4.026    3      G        24    568.75    568.75    3.16    0.33  0.91  0.29  0.009 A023    M-182, M-166        OWD-20-6"      Waste Disposal    Bld to Bld Pen  Open Sleeve  Class 1      TB    Aux              Waste Disposal          6.625    0.28    6.065    3      G        24      573        573      4.76    0.72  0.91  0.44  0.020 A024    M-182, M-166      OCD-068-18"        Condensate      Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux                Condensate              18    0.562  16.876    3      G        24      571        571      13.25    5.30  0.91  1.23  0.150 A025    M-180, M-166,      OSW-019-36"      Service Water    Bld to Bld Pen  Open Sleeve  Class 3      TB    Aux      Service Water Supply Header      36      0.75    34.5    3      G        23      575        575      27.10  21.21  0.91  2.52  0.600 Service Water to DG                                                            Service Water Supply to Diesel A027 M-102, M-168. M-185  OSW-008-12"            Hxs        Bld to Bld Pen  Buried Pipe  Class 3      DG    Aux        Generator Heat Exchangers      12.75  0.406  11.938  74.50    G        10    554.75      567.5    232.84  57.91  22.71 21.63 1.640 Service Water to DG A028 M-102, M-168. M-185  OSW-008-12"            Hxs        Bld to Bld Pen  Buried Pipe  Class 3      DG    Aux        Service Water to DG Hxs      12.75  0.406  11.938  77.67    G        10    553.33      567.5    242.75  60.37  23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pool -
A029 197, M-106 Sect K-K    1SF-017-2"      Demin Water      Bld to Yard Pen Buried Pipe  Class 3      Aux    SFB      Spent Fuel Pool - Demin Water    2.375  0.154    2.067  89.58    R        24    570.58    583.33    48.48    2.09  27.31 4.50  0.059 Service Water Supply to Diesel A030    M-102, M-169      OSW-001-12"      Service Water    Bld to Bld Pen  Buried Pipe  Class 3      DG    Aux        Generator Heat Exchangers      12.75  0.406  11.938  74.50    G        30    554.75      567.5    232.84  57.91  22.71 21.63 1.640 Service Water Supply to Diesel A031    M-102, M-169      OSW-001-12"      Service Water    Bld to Bld Pen  Buried Pipe  Class 3      DG    Aux        Generator Heat Exchangers      12.75  0.406  11.938  77.67    G        30    553.33      567.5    242.75  60.37  23.67 22.55 1.710 See Multiple CTMT to Aux Pens on M-Main    282 and M-662 cover in CTMT A034        M-106              Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 3      Aux    Stm                Worksheet              14    0.438  13.124  2.00    H        30      571        571      6.87    1.88  0.61  0.64  0.053 M-107 Sh 1, 2 ,3 , M-A036 197, M-106 Sect K-K    1SI-012-24"    Safety Injection  Bld to Yard Pen Buried Pipe Unimpacted    Aux    SFB              Safety Injection          24    0.688  22.624  70.11    R        24      570        0      415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-  1AD-149-1    Spent Fuel Pit Tell A037 197, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux    SFB              Aerated Drain            1.9    0.145    1.61  30.75    R        24      571    Unknown    4.05    0.14  2.93  0.38  0.004 M-107 Sh 1, 2 ,3 , M-  1AD-148-1    Spent Fuel Pit Tell A038 197, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux    SFB              Aerated Drain            1.9    0.145    1.61  30.75    R        24      571    Unknown    11.68    0.39  8.44  1.08  0.011 M-107 Sh 1, 2 ,3 , M-  1AD-147-1    Spent Fuel Pit Tell A039 197, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux    SFB              Aerated Drain            1.9    0.145    1.61  17.75    R        24      571    Unknown    7.48    0.25  5.41  0.70  0.007 Page 103 of 123
Attachment I                                                                                                  TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space          Int  Void Pen                        U1 Line Ident                                                  MARSSIM                                                      OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume  Length  SA  Space No.        Drawings              No.            System        Category        End Sate    Class      From  To              Description            inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3  meters  m2    m3 M-107 Sh 1, 2 ,3 , M-A040  197, M-106 Sect K-K    1AD-146-4"      Aerated Drain    Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB            Aerated Drain            4.5    0.237    4.026  124.52    R        24    569.33      584    131.25    11.01  37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M-A041  197, M-106 Sect K-K  1SA-014-1 1/2"      Station Air    Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB              Service Air            1.9    0.145    1.61  94.17    R        24    569.33      583      39.69    1.33  28.70 3.69  0.038 M-107 Sh 1, 2 ,3 , M-A042  197, M-106 Sect K-K    ODW-100-2"        Demin Water      Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB              Demin Water            2.375  0.154    2.067  63.55    R        24    570.58      484      34.39    1.48  19.37 3.19  0.042 M-107 Sh 1, 2 ,3 , M-A043  197, M-106 Sect K-K    OFP-016-4"      Fire Protection  Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB            Fire Protection            4.5    0.237    4.026  91.08    R        24    570.58      584      96.00    8.05  27.76 8.92  0.228 M-107 Sh 1, 2 ,3 , M-A044  197, M-106 Sect K-K    1SW-181-2"      Service Water    Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB            Service Water            2.375  0.154    2.067  92.58    R        24    570.58      584      50.10    2.16  28.22 4.65  0.061 M-107 Sh 1, 2 ,3 , M-A046  197, M-106 Sect K-K  01A-004-1 1/2"    Instrument Air    Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB            Instrument Air            1.9    0.145    1.61  94.00    R        24    570.58      584      39.62    1.33  28.65 3.68  0.038 M-107 Sh 1, 2 ,3 , M-A047  197, M-106 Sect K-K    1SF-022-3"      Spent Fuel Pool  Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB        Spent Fuel Pit Cooling        3.5    0.216    3.068  84.42    R        24    569.33      583      67.80    4.33  25.73 6.30  0.123 M-107 Sh 1, 2 ,3 , M-A048  197, M-106 Sect K-K    1SF-008-2"      Spent Fuel Pool  Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB        Spent Fuel Pit Cooling      2.375  0.154    2.067  86.00    R        24    569.33      583      46.54    2.00  26.21 4.32  0.057 M-107 Sh 1, 2 ,3 , M-A049  197, M-106 Sect K-K    1CC-078-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2      Aux  SFB          Component Cooling          10.75  0.365    10.02  128.08    R        24    570.58      584    335.99    70.14  39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M-A050  197, M-106 Sect K-K    1CC-080-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2      Aux  SFB          Component Cooling          10.75  0.365    10.02  130.92    R        24    570.58      584    343.42    71.69  39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M-A051  260, M-106 Sect K-K    2SI-012-24"    Safety Injection  Bld to Yard Pen Buried Pipe Unimpacted    Aux  SFB            Safety Injection          24    0.688  22.624  70.11    R        16      570        573    415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-  2AD-149-1    Spent Fuel Pit Tell A052  260, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux  SFB            Aerated Drain            1.9    0.145    1.61  30.75    R        16      571    Unknown    4.05    0.14  2.93  0.38  0.004 M-107 Sh 1, 2 ,3 , M-  2AD-148-1    Spent Fuel Pit Tell A053  260, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux  SFB            Aerated Drain            1.9    0.145    1.61  30.75    R        16      571    Unknown    11.68    0.39  8.44  1.08  0.011 M-107 Sh 1, 2 ,3 , M-  2AD-147-1    Spent Fuel Pit Tell A054  260, M-106 Sect K-K        1/2"          Tale Lines      Bld to Bld Pen  Buried Pipe  Class 1      Aux  SFB            Aerated Drain            1.9    0.145    1.61  17.75    R        16      571    Unknown    7.48    0.25  5.41  0.70  0.007 M-107 Sh 1, 2 ,3 , M-A055  260, M-106 Sect K-K    2SF-008-2"      Spent Fuel Pool  Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB        Spent Fuel Pit Cooling      2.375  0.154    2.067  113.25    R        16    569.33      583      61.28    2.64  34.52 5.69  0.075 M-107 Sh 1, 2 ,3 , M-A056  260, M-106 Sect K-K    2SF-022-3"      Spent Fuel Pool  Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB        Spent Fuel Pit Cooling        3.5    0.216    3.068  111.00    R        16    569.33      583      89.16    5.70  33.83 8.28  0.161 M-107 Sh 1, 2 ,3 , M-A057  260, M-106 Sect K-K    0SF-012-3"      Spent Fuel Pool  Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB        Spent Fuel Pit Cooling        3.5    0.216    3.068  109.50    R        16    569.33      583      87.95    5.62  33.38 8.17  0.159 M-107 Sh 1, 2 ,3 , M-A058  260, M-106 Sect K-K    0CT-061-2"        Waste Drain    Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB Decon Pad Drain to Chem Drain Tank  2.375  0.154    2.067  89.75    R        16    569.33      583      48.57    2.09  27.36 4.51  0.059 M-107 Sh 1, 2 ,3 , M-A059  260, M-106 Sect K-K    2CC-078-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2      Aux  SFB          Component Cooling          10.75  0.365    10.02  108.58    R        16    570.58      584    284.84    59.46  33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M-A060  260, M-106 Sect K-K    2CC-080-10"    Component Cooling  Bld to Yard Pen Buried Pipe  Class 2      Aux  SFB          Component Cooling          10.75  0.365    10.02  106.42    R        16    570.58      584    279.16    58.27  32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M-A061  260, M-106 Sect K-K    2DW-008-3"        Demin Water      Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB        Demineralized Water          3.5    0.216    3.068  128.25    R        16    569.33      583    103.01    6.58  39.09 9.57  0.186 M-107 Sh 1, 2 ,3 , M-A062  197, M-106 Sect K-K    2AD-146-4"      Aerated Drain    Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB            Aerated Drain            4.5    0.237    4.026  129.67    R        16    570.58      584    136.67    11.46  39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M-A063  260, M-106 Sect K-K    2DW-014-3"        Demin Water      Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB        Demineralized Water          3.5    0.216    3.068  126.67    R        16    570.58      583    101.74    6.50  38.61 9.45  0.184 M-107 Sh 1, 2 ,3 , M-  OWD-059-2 A064  260, M-106 Sect K-K        1/2"        Waste Disposal    Bld to Yard Pen Buried Pipe  Class 1      Aux  SFB            Waste Disposal            2.875  0.203    2.469  123.67    R        16    570.58      584      79.94    4.11  37.69 7.43  0.116 M-107 Sh 1, 2 ,3 , M-A065  260, M-106 Sect K-K    2SW-243-3"      Service Water    Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB            Service Water            3.5    0.216    3.068  124.67    R        16    569.33      584    100.13    6.40  38.00 9.30  0.181 M-107 Sh 1, 2 ,3 , M-A066  260, M-106 Sect K-K  2SA-012-1 1/2"      Station Air    Bld to Yard Pen Buried Pipe  Class 3      Aux  SFB              Service Air            1.9    0.145    1.61  124.50    R        16    569.33      583      52.48    1.76  37.95 4.88  0.050 M-104 & M-105 sh 1,                  Service Water Supply                                                    Service Water Supply Header Aux Pen C026      M-102, M-168        OSW-014-48"    Header Under TB    Bld to Yard Pen Buried Pipe  Class 3      Aux Yard              to Under TB              48    0.625    46.75  171.50    G        19    549.67    549.67    174.92  2044.35  52.27 16.25 57.889 Service Water Supply                                                      Service Water Supply Header at TB C026a M-105 SH 1 & 2, M-272  OSW-014-48"          Header        Bld to Yard Pen Buried Pipe  Class 3      Aux Yard            Foundation Exit            48    0.625    46.75  37.33    C        19      579      549.67    38.08  445.03  11.38 3.54  12.602 M-104 & M-105 sh 1,                  Service Water Supply                                                    Service Water Supply Header Aux Pen C029      M-102, M-168        OSW-013-48"    Header Under TB    Bld to Yard Pen Buried Pipe  Class 3      Aux Yard              to Under TB              48    0.625    46.75  171.50    G        21    549.67    549.67    174.92  2044.35  52.27 16.25 57.889 Service Water Supply                                                      Service Water Supply Header at TB C029a M-105 SH 1 & 2, M-272  OSW-013-48"          Header        Bld to Yard Pen Buried Pipe  Class 3      Aux Yard            Foundation Exit            48    0.625    46.75  37.33    C        21      579      549.67    38.08  445.03  11.38 3.54  12.602 U1 P001      M-281, M-661        1-FP-037-4"    Fire Protection  Bld to Bld Pen  Open Sleeve  Class 3    CTMT  Aux            Fire Protection            4.5    0.237    4.026  4.83    107      253      577.5      577.5    12.65    2.64  1.47  1.18  0.075 U1 P002      M-281, M-661            Spare              N/A        Bld to Bld Pen  Open Sleeve  Class 2    CTMT  Aux                  Spare                0      0        0    4.83  98-30    261-30  588.83    588.83    7.59    0.95  1.47  0.71  0.027 Page 104 of 123
Attachment I                                                                                                        TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                    Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                              MARSSIM                                                          OD      Wall  Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings              No.          System      Category        End Sate    Class      From    To                Description            inches Thickness  inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 U1 P003    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                    Spare                  0        0        0  4.83    98-15  263-45    577.5      577.5    7.59    0.95  1.47  0.71  0.027 U1 P004    M-281, M-661        1-S1-090-3"  Safety Injection Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux  Boron Injection Tank to Cold Legs      3.5    0.438    2.624  4.83      94    266      577.5      577.5    10.12    1.69  1.47  0.94  0.048 U1 P005    M-281, M-661      1-MS-001-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Main Steam                34    1.15625  31.6875    4      213    147      579.5      579.5    52.36  54.54  1.22  4.86  1.544 U1 P006    M-281, M-661      1-MS-002-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Main Steam                34    1.15625  31.6875    4      213    147      579.5      579.5    52.36  54.54  1.22  4.86  1.544 1-MS-003-35                                                                    U1 P007    M-281, M-661            1/2"      Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Main Steam              35.5    1.1875  33.125    4      333      27      579.5      579.5    52.36  54.54  1.22  4.86  1.544 1-MS-004-35                                                                    U1 P008    M-281, M-661            1/2"      Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Main Steam              35.5    1.1875  33.125    4      333      27      579.5      579.5    52.36  54.54  1.22  4.86  1.544 U1 P009    M-281, M-661      1-FW-014-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U1 P010    M-281, M-661      1-FW-017-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U1 P011    M-281, M-661      1-FW-011-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      333      27    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U1 P012    M-281, M-661      1-FW-022-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      333      27    586.83    586.83    33.51  22.34  1.22  3.11  0.633 Residual Heat                                          U1          Reactor Coolant No. 1 Loop to Residual P017    M-281, M-661      1-RH-015-14"      Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux          Heat Removal Pumps              14    0.438    13.124  4.83    107    253    584.25    584.25    35.43  20.67  1.47  3.29  0.585 U1 P018    M-281, M-661      1-CF-004-10"      Cavity Fill  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux    Cavity Fill Pump 1A Discharge      10.75  0.365    10.02  4.83  102-45  257-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U1            Component Cooling Water Supply P019    M-281, M-661      1-CC-091-6"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux              Header to RCPs            6.625    0.28    6.065  4.83    107    253    586.83    586.83    15.18    3.80  1.47  1.41  0.107 U1 P020    M-281, M-661      1-CF-003-10"      Cavity Fill  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux    Cavity Fill Pump 1B Discharge      10.75  0.365    10.02  4.83  100-45  259-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U1 P021    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                    Spare                  0        0        0  4.83    98-30  261-30  584.25    584.25    35.43  20.67  1.47  3.29  0.585 Residula Heat                                          U1          Residual Heat Exchanger to RC Loop P022    M-281, M-661      1-RH-006-12"      Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux                Cold Legs              12.75  0.406    11.938  4.83    98-30  261-30  580.08    580.08    35.43  20.67  1.47  3.29  0.585 U1            RC Pumps to Comp Cooling Pump P023    M-281, M-661      1-CC-106-6"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Suction              6.625    0.28    6.065  4.83  100-45  259-15  586.83    586.83    15.18    3.80  1.47  1.41  0.107 U1 P024    M-281, M-661        1-SI-104-4"  Safety Injection Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux  Safety Inj Pumps to RC Loop Hot Leg    4.5    0.438    3.624  4.83    107    253    588.83    588.83    17.72    5.17  1.47  1.65  0.146 U1            RC Pumps to Comp Cooling Pump P033    M-281, M-661      1-CC-104-3"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Suction                3.5    0.216    3.068  4.83  102-45'  257-15  588.83    588.83    15.18    3.80  1.47  1.41  0.107 U1 P034    M-281, M-661      1-DW-006-2"    Demin Water    Bld to Bld Pen Open Sleeve  Class 3    CTMT    Aux              Demin Water              2.375  0.154    2.067  4.83    96-15'  263-45  588.83    588.83    15.18    3.80  1.47  1.41  0.107 B-278, M-7, B-223, M-                                                  Pipe in                U1 P035        170,            1SI-008-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Recirculating Sump Suction        20    0.594    18.812  51.17    135    225    561.25    561.25    251.99  98.76  15.60 23.41 2.797 B-278, M-7, B-223, M-                                                  Pipe in                U1 P036        170,          1CF-002-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Cavity Flood Sump Suction          20    0.594    18.812  50.75    135    225    561.25    561.25    249.94  97.96  15.47 23.22 2.774 B-278, M-7, B-223, M-                                                  Pipe in                U1 P037        170,          1CF-001-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Cavity Flood Sump Suction          20    0.594    18.812  50.83    135    225    561.25    561.25    250.35  98.12  15.49 23.26 2.778 1-WO-95-1                                                            U1          CTMT Sump Pump Dischage to Aux P042    M-281, M-661            1/2"      Rad Discharge  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux      Bld Flr Drain Analysis Tank        1.9    0.145      1.61  4.83  104-45  255-15  577.50    577.50    7.59    0.95  1.47  0.71  0.027 U1          RC Drain Pump Discharge to Hold-Up P043    M-281, M-661      1-DT-036-3"    Rad Discharge  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux                    Tank                  3.5    0.216    3.068  4.83    107    253    580.08    580.08    10.12    1.69  1.47  0.94  0.048 U1 P050    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                    Spare                  0        0        0  4.83    96-15'  263-45  580.08    580.08    12.65    2.64  1.47  1.18  0.075 Containment                                            U1 P054    M-281, M-661      1-CS-063-2"      Pressure    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux          Containment Pressure          2.375  0.154    2.067  4.83  109-15'  250-45  586.83    586.83    7.59    0.95  1.47  0.71  0.027 U1 P056    M-281, M-661      1-VF-132-2"    Filtered Vents  Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux              Filtered Vents            2.375  0.154    2.067  4.83  100-45'  250-15  580.08    580.08    10.12    1.69  1.47  0.94  0.048 U1 P064    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                    Spare                  0        0        0  4.83      94    266    586.83    586.83    12.65    2.64  1.47  1.18  0.075 1-VC-033,043,                                                          U1 P066    M-281, M-661      052E, 085-2"    Seal Water    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  RC Pump Seal Water Supply Lines        14    0.437    13.126  4.83  102-45'  257-15  580.08    580.08    17.72    5.17  1.47  1.65  0.146 U1 P067    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                    Spare                  0        0        0  4.83  108-15'  249-45  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U1 P068    M-281, M-661      1-FW-018-3"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1C        3.5    0.438    2.624  4.83  100-45'  259-15  577.50    577.50    17.72    5.17  1.47  1.65  0.146 Page 105 of 123
Attachment I                                                                                                        TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                    Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                              MARSSIM                                                          OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings            No.          System        Category        End Sate    Class      From    To              Description              inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 U1 P069    M-281, M-661      1-FW-015-3"      Feedwater      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1A        3.5    0.438    2.624  4.83  109-15'  250-45  577.50    577.50    17.72    5.17  1.47  1.65  0.146 U1          Refueling Cavity Drain to Purification P070    M-281, M-661      1-DT-032-3"    Cavity Drain    Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux            Pump Suction                3.5    0.216    3.068  4.83  102-45'  257-15  577.50    577.50    17.72    5.17  1.47  1.65  0.146 1-BD-001-2                                                            U1 P071    M-281, M-661          1/2"      SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux      Steam Generator Blowdown          2.875  0.276    2.323  4.83  104-45'  255-15  588.83    588.83    17.72    5.17  1.47  1.65  0.146 U1 P073    M-281, M-661          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83  104-45'  255-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U1 P074    M-281, M-661      1-FW-012-3"      Feedwater      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1D        3.5    0.438    2.624  4.83  104-45'  255-15  586.83    586.83    17.72    5.17  1.47  1.65  0.146 U1 P076    M-282, M-662      1-SS-026-3/8"  Sample Line    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux      Accumulator Tank Sample          0.675  0.065    0.545  4.83  109-15'  250-45  588.83    588.83    17.72    5.17  1.47  1.65  0.146 U1 P081    M-281, M-661      1-VN-008-2"  Vent Non-filtered Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux          Non-Filtered Vents            2.375  0.154    2.067  4.83  109-15'  250-45  580.08    580.08    10.12    1.69  1.47  0.94  0.048 U1 P084    M-281, M-661          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83      94    266    588.83    588.83    12.65    2.64  1.47  1.18  0.075 U1 P085    M-281, M-661          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83  100-45'  259-45  588.83    588.83    12.65    2.64  1.47  1.18  0.075 1-SS-001,2,3-                                                          U1            Press Stem, Press Liq, RC Hot Leg P086    M-282, M-661          3/8"      Sample Line    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Samples                  0.675  0.065    0.545  4.83  102-45'  257-15  586.83    586.83    12.65    2.64  1.47  1.18  0.075 U1 P087    M-281, M-661          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83    96-15'  263-45  584.25    584.25    12.65    2.64  1.47  1.18  0.075 U1 P088    M-281, M-661      1-HS-030-2"      Heating      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  Heating System Hot Water Supply      2.375  0.218    1.939  4.83    98-30'  261-30  586.83    586.83    15.18    3.80  1.47  1.41  0.107 U1 P089    M-281, M-661      0-HS-053-2"      Heating      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  Heating System Hot Water Return      2.375  0.218    1.939  4.83    96-15'  263-45  586.83    586.83    15.18    3.80  1.47  1.41  0.107 U1 P090    M-282, M-662          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83      94    266    584.25    584.25    35.43  20.67  1.47  3.29  0.585 1-BD-007-2                                                                    U1 P091    M-281, M-661          1/2"      SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.875  0.276    2.323    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U1 P092    M-281, M-661      1-BD-008-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.375  0.218    1.939    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U1 P093    M-281, M-661      1-BD-006-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.375  0.218    1.939    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 1-BD-005-2                                                                    U1 P094    M-281, M-661          1/2"      SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.875  0.276    2.323    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U1 P095    M-281, M-661      1-BD-007-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.375  0.218    1.939    4      213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.121 U1 P096    M-281, M-661      1-BD-005-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.375  0.218    1.939    4      213    147    580.33    580.33    14.66    4.28  1.22  1.36  0.121 U1 P097    M-281, M-661      1-BD-003-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1D          2.375  0.218    1.939    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.121 U1 P098    M-281, M-661      1-BD-001-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1B          2.375  0.218    1.939    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36  0.121 U1 P103    M-282, M-662          Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Spare                    0      0        0    4.83    98-30'  261-30  577.50    577.50    10.12    1.69  1.47  0.94  0.048 U1 P104    M-282, M-662      1-MS-018-6"  Reactor Coolant  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux        SIM to Aux F.S. Pumps            6.625  0.432    5.761  4.83      94    266    580.08    580.08    30.37  15.18  1.47  2.82  0.430 Residula Heat                                            U1          Residual Heat Exchanger to RC Loop P105    M-282, M-662      1-SI-011-10"      Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux              Hot Legs                  10.75  1.125    8.5    4.83  104-45  255-15  580.08    580.08    22.78    8.54  1.47  2.12  0.242 U1 P112    M-282, M-662      1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Steam Generator Blowdown Sample        0.675  0.065    0.545    4      213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.158 U1 P113    M-282, M-662      1-SS-041-3/8"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Steam Generator Blowdown Sample        0.675  0.065    0.545    4      333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.158 1-BD-003-2                                                                    U1 P115    M-282, M-662          1/2"      SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Blowdown (Steam Generator 1D)        2.875  0.276    2.323    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U1 P116    M-282, M-662      1-BD-004-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Blowdown (Steam Generator 1D)        2.375  0.218    1.939    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U1 P117    M-282, M-662      1-BD-002-2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown (Steam Generator 1B)        2.375  0.218    1.939    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 1-BD-001-2                                                                    U1 P118    M-282, M-662          1/2"      SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown (Steam Generator 1B)        2.875  0.276    2.323    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 B-278, M-7, B-223, M-                                                  Pipe in                U1 P123        170,          1SI-007-20"      Drain        Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Recirculating Sump Suction          20    0.594  18.812    52      135    225    561.25    561.25    256.10  100.37  15.85 23.79 2.842 Page 106 of 123
Attachment I                                                                                                        TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                    Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                              MARSSIM                                                          OD      Wall  Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings              No.          System      Category        End Sate    Class      From    To                Description              inches Thickness  inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 B-278, M-7, B-223, M-                                                  Pipe in                U1 P124        170,          1SI-009-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Recirculating Sump Suction        20    0.594    18.812  52.83    135    225    561.25    561.25    260.20  101.98  16.10 24.17 2.888 U1 P127    M-282, M-662      1-MS-018-6"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT        Steam to Aux FW Pumps            6.625  0.432    5.761    4      213    147    578.08    578.08    16.76    5.59  1.22  1.56  0.158 U1 P128    M-282, M-662      1-MS-017-6"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT        Steam to Aux FW Pumps            6.625  0.432    5.761    4      333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.158 U2 P201    M-281, M-661      2-FP-037-4"    Fire Protection Bld to Bld Pen Open Sleeve  Class 3    CTMT    Aux              Fire Protection            4.5    0.237    4.026  4.83    107    253    577.50    577.50    12.65    2.64  1.47  1.18  0.075 U2 P202    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                  0        0        0  4.83    98-30  261-30  588.83    588.83    7.59    0.95  1.47  0.71  0.027 U2 P203    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                  0        0        0  4.83    98-15  263-45  577.50    577.50    7.59    0.95  1.47  0.71  0.027 U2 P204    M-281, M-661      2-S1-090-3"  Safety Injection Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux  Boron Injection Tank to Cold Legs      3.5    0.438    2.624  4.83      94    266    577.50    577.50    10.12    1.69  1.47  0.94  0.048 U2 P205    M-281, M-661      2-MS-001-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT              Main Steam                34    1.15625  31.6875    4      213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.544 U2 P206    M-281, M-661      2-MS-002-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT              Main Steam                34    1.15625  31.6875    4      213    147    579.50    579.50    52.36  54.54  1.22  4.86  1.544 2-MS-003-35                                                                    U2 P207    M-281, M-661            1/2"      Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT              Main Steam                35.5    1.1875  33.125    4      333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.544 2-MS-004-35                                                                    U2 P208    M-281, M-661            1/2"      Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT              Main Steam                35.5    1.1875  33.125    4      333      27    579.50    579.50    52.36  54.54  1.22  4.86  1.544 U2 P209    M-281, M-661      2-FW-014-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U2 P210    M-281, M-661      2-FW-017-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      213    147    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U2 P211    M-281, M-661      2-FW-011-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      333      27    584.58    584.58    33.51  22.34  1.22  3.11  0.633 U2 P212    M-281, M-661      2-FW-022-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT                Feedwater                16    1.218    13.564    4      333      27    586.83    586.83    33.51  22.34  1.22  3.11  0.633 Residula Heat                                          U2          Reactor Coolant No. 1 Loop to Residual P217    M-281, M-661      2-RH-015-14"      Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux          Heat Removal Pumps              14    0.438    13.124  4.83    107    253    584.25    584.25    35.43  20.67  1.47  3.29  0.585 U2 P218    M-281, M-661      2-CF-004-10"      Cavity Fill  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux    Cavity Fill Pump 1A Discharge      10.75  0.365    10.02  4.83  102-45  257-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U2            Component Cooling Water Supply P219    M-281, M-661      2-CC-091-6"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux              Header to RCPs            6.625    0.28    6.065  4.83    107    253    586.83    586.83    15.18    3.80  1.47  1.41  0.107 U2 P220    M-281, M-661      2-CF-003-10"      Cavity Fill  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux    Cavity Fill Pump 1B Discharge      10.75  0.365    10.02  4.83  100-45  259-15  584.25    584.25    22.78    8.54  1.47  2.12  0.242 U2 P221    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                  0        0        0  4.83    98-30  261-30  584.25    584.25    35.43  20.67  1.47  3.29  0.585 Residula Heat                                          U2          Residual Heat Exchanger to RC Loop P222    M-281, M-661      2-RH-006-12"      Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux                Cold Legs                12.75  0.406    11.938  4.83    98-30  261-30  580.08    580.08    35.43  20.67  1.47  3.29  0.585 U2            RC Pumps to Comp Cooling Pump P223    M-281, M-661      2-CC-106-6"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Suction                6.625    0.28    6.065  4.83  100-45  259-15  586.83    586.83    15.18    3.80  1.47  1.41  0.107 U2 P224    M-281, M-661        2-SI-104-4"  Safety Injection Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux  Safety Inj Pumps to RC Loop Hot Leg    4.5    0.438    3.624  4.83    107    253    588.83    588.83    17.72    5.17  1.47  1.65  0.146 U2            RC Pumps to Comp Cooling Pump P233    M-281, M-661      2-CC-104-3"  Component Cooling Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Suction                3.5    0.216    3.068  4.83  102-45'  257-15  588.83    588.83    15.18    3.80  1.47  1.41  0.107 U2 P234    M-281, M-661      2-DW-006-2"      Demin Water    Bld to Bld Pen Open Sleeve  Class 3    CTMT    Aux              Demin Water              2.375  0.154    2.067  4.83    96-15'  263-45  588.83    588.83    15.18    3.80  1.47  1.41  0.107 B-278, M-7, B-223, M-                                                  Pipe in                U2 P235        170,          2SI-008-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Recirculating Sump Suction        20    0.594    18.812  51.17    135    225    561.25    561.25    251.99  98.76  15.60 23.41 2.797 B-278, M-7, B-223, M-                                                  Pipe in                U2 P236        170,          2CF-002-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Cavity Flood Sump Suction          20    0.594    18.812  50.75    135    225    561.25    561.25    249.94  97.96  15.47 23.22 2.774 B-278, M-7, B-223, M-                                                  Pipe in                U2 P237        170,          2CF-001-20"        Drain      Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux      Cavity Flood Sump Suction          20    0.594    18.812  50.83    135    225    561.25    561.25    250.35  98.12  15.49 23.26 2.778 2-WO-95-1                                                            U2          CTMT Sump Pump Dischage to Aux P242    M-281, M-661            1/2"      Rad Discharge  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux      Bld Flr Drain Analysis Tank        1.9    0.145      1.61  4.83  104-45  255-15  577.50    577.50    7.59    0.95  1.47  0.71  0.027 U2          RC Drain Pump Discharge to Hold-Up P243    M-281, M-661      2-DT-036-3"    Rad Discharge  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux                  Tank                  3.5    0.216    3.068  4.83    107    253    580.08    580.08    10.12    1.69  1.47  0.94  0.048 U2 P250    M-281, M-661          Spare            N/A      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                  0        0        0  4.83    96-15'  263-45  580.08    580.08    12.65    2.64  1.47  1.18  0.075 Containment                                            U2 P254    M-281, M-661      2-CS-063-2"      Pressure    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux          Containment Pressure          2.375  0.154    2.067  4.83  109-15'  250-45  586.83    586.83    7.59    0.95  1.47  0.71  0.027 Page 107 of 123
Attachment I                                                                                                        TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                                    Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen              U1 Line Ident                                              MARSSIM                                                          OD    Wall    Pipe ID Length Degrees  Degrees              End      Area    Volume Length SA  Space No. Drawings          No.          System      Category        End Sate    Class      From    To              Description              inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters m2    m3 U2 P256 M-281, M-661  2-VF-132-2"  Filtered Vents  Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux            Filtered Vents              2.375  0.154    2.067  4.83  100-45'  250-15  580.08    580.08    10.12    1.69  1.47  0.94 0.048 U2 P264 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83      94    266    586.83    586.83    12.65    2.64  1.47  1.18 0.075 2-VC-033,043,                                                          U2 P266 M-281, M-661  052E, 085-2"    Seal Water    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  RC Pump Seal Water Supply Lines        2.375  0.344    1.687  4.83  102-45'  257-15  580.08    580.08    17.72    5.17  1.47  1.65 0.146 U2 P267 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83  108-15'  249-45  584.25    584.25    22.78    8.54  1.47  2.12 0.242 U2 P268 M-281, M-661  2-FW-018-3"    Feedwater      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1C        3.5    0.438    2.624  4.83  100-45'  259-15  577.50    577.50    17.72    5.17  1.47  1.65 0.146 U2 P269 M-281, M-661  2-FW-015-3"    Feedwater      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1A        3.5    0.438    2.624  4.83  109-15'  250-45  577.50    577.50    17.72    5.17  1.47  1.65 0.146 U2          Refueling Cavity Drain to Purification P270 M-281, M-661  2-DT-032-3"    Cavity Drain    Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux            Pump Suction                3.5    0.216    3.068  4.83  102-45'  257-15  577.50    577.50    17.72    5.17  1.47  1.65 0.146 2-BD-001-2                                                            U2 P271 M-281, M-661      1/2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux      Steam Generator Blowdown          2.875  0.276    2.323  4.83  104-45'  255-15  588.83    588.83    17.72    5.17  1.47  1.65 0.146 U2 P273 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83  104-45'  255-15  584.25    584.25    22.78    8.54  1.47  2.12 0.242 U2 P274 M-281, M-661  2-FW-012-3"    Feedwater      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux    Aux Feedwater to Steam Gen 1D        3.5    0.438    2.624  4.83  104-45'  255-15  586.83    586.83    17.72    5.17  1.47  1.65 0.146 U2 P276 M-282, M-662 2-SS-026-3/8"  Sample Line    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux      Accumulator Tank Sample          0.675  0.065    0.545  4.83  109-15'  250-45  588.83    588.83    17.72    5.17  1.47  1.65 0.146 U2 P281 M-281, M-661  2-VN-008-2"  Vent Non-filtered Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux          Non-Filtered Vents            2.375  0.154    2.067  4.83  109-15'  250-45  580.08    580.08    10.12    1.69  1.47  0.94 0.048 U2 P284 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83      94    266    588.83    588.83    12.65    2.64  1.47  1.18 0.075 U2 P285 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83  100-45'  259-45  588.83    588.83    12.65    2.64  1.47  1.18 0.075 2-SS-001,2,3-                                                          U2            Press Stem, Press Liq, RC Hot Leg P286 M-282, M-661      3/8"      Sample Line    Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                Samples                  0.675  0.065    0.545  4.83  102-45'  257-15  586.83    586.83    12.65    2.64  1.47  1.18 0.075 U2 P287 M-281, M-661      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83    96-15'  263-45  584.25    584.25    12.65    2.64  1.47  1.18 0.075 U2 P288 M-281, M-661  2-HS-030-2"      Heating      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  Heating System Hot Water Supply      2.375  0.218    1.939  4.83    98-30'  261-30  586.83    586.83    15.18    3.80  1.47  1.41 0.107 U2 P289 M-281, M-661  0-HS-053-2"      Heating      Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux  Heating System Hot Water Return      2.375  0.218    1.939  4.83    96-15'  263-45  586.83    586.83    15.18    3.80  1.47  1.41 0.107 U2 P290 M-282, M-662      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83      94    266    584.25    584.25    35.43    20.67  1.47  3.29 0.585 2-BD-007-2                                                                    U2 P291 M-281, M-661      1/2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.875  0.276    2.323    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 U2 P292 M-281, M-661  2-BD-008-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.375  0.218    1.939    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 U2 P293 M-281, M-661  2-BD-006-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.375  0.218    1.939    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 2-BD-005-2                                                                    U2 P294 M-281, M-661      1/2"    SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.875  0.276    2.323    4      213    147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 U2 P295 M-281, M-661  2-BD-007-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1A          2.375  0.218    1.939    4      213    147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 U2 P296 M-281, M-661  2-BD-005-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1C          2.375  0.218    1.939    4      213    147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 U2 P297 M-281, M-661  2-BD-003-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1D          2.375  0.218    1.939    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 U2 P298 M-281, M-661  2-BD-001-2"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Blowdown Steam Generator 1B          2.375  0.218    1.939    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 U2 P303 M-282, M-662      Spare          N/A        Bld to Bld Pen Open Sleeve  Class 2    CTMT    Aux                  Spare                    0      0        0    4.83    98-30'  261-30  577.50    577.50    10.12    1.69  1.47  0.94 0.048 U2 P304 M-282, M-662  2-MS-018-6"  Reactor Coolant  Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux        SIM to Aux F.S. Pumps            6.625  0.432    5.761  4.83      94    266    580.08    580.08    30.37    15.18  1.47  2.82 0.430 Residual Heat                                            U2          Residual Heat Exchanger to RC Loop P305 M-282, M-662  2-SI-011-10"    Removal      Bld to Bld Pen Open Sleeve  Class 1    CTMT    Aux                Hot Legs                10.75  1.125    8.5    4.83  104-45  255-15  580.08    580.08    22.78    8.54  1.47  2.12 0.242 U2 P312 M-282, M-662 2-SS-041-3/8"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Steam Generator Blowdown Sample        0.675  0.065    0.545    4      213    147    578.08    578.08    16.76    5.59  1.22  1.56 0.158 U2 P313 M-282, M-662 2-SS-041-3/8"  SG Blowdown      Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT  Steam Generator Blowdown Sample        0.675  0.065    0.545    4      333      27    578.08    578.08    16.76    5.59  1.22  1.56 0.158 Page 108 of 123
Attachment I                                                                                              TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List                                                                          Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                          Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                        MARSSIM                                                  OD    Wall    Pipe ID Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings            No.        System  Category        End Sate    Class      From    To          Description          inches Thickness inches  Feet  -minutes -minutes Elevation  Elevation    ft2      ft3 meters  m2    m3 2-BD-003-2                                                              U2 P315    M-282, M-662          1/2"    SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT Blowdown (Steam Generator 1D)  2.875  0.276    2.323    4    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U2 P316    M-282, M-662      2-BD-004-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT Blowdown (Steam Generator 1D)  2.375  0.218    1.939    4    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 U2 P317    M-282, M-662      2-BD-002-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT Blowdown (Steam Generator 1B)  2.375  0.218    1.939    4    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 2-BD-001-2                                                              U2 P318    M-282, M-662          1/2"    SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT Blowdown (Steam Generator 1B)  2.875  0.276    2.323    4    333      27    584.58    584.58    16.76    5.59  1.22  1.56  0.158 B-278, M-7, B-223, M-                                            Pipe in                U2 P323        170,          2SI-007-20"      Drain  Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux  Recirculating Sump Suction    20    0.594  18.812    52    135      225    561.25    561.25    256.10  100.37  15.85 23.79 2.842 B-278, M-7, B-223, M-                                            Pipe in                U2 P324        170,          2SI-009-20"      Drain  Bld to Bld Pen  Sleeve    Class 1    CTMT    Aux  Recirculating Sump Suction    20    0.594  18.812  52.83  135      225    561.25    561.25    260.20  101.98  16.10 24.17 2.888 U2 P327    M-282, M-662      2-MS-018-6"    Main Steam Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Steam to Aux FW Pumps      6.625  0.432    5.761    4    213      147    578.08    578.08    16.76    5.59  1.22  1.56  0.158 U2 P328    M-282, M-662      2-MS-017-6"    Main Steam Bld to Bld Pen Open Sleeve  Class 2  Main Stm CTMT    Steam to Aux FW Pumps      6.625  0.432    5.761    4    333      27    578.08    578.08    16.76    5.59  1.22  1.56  0.158 Page 109 of 123
Attachment J                                                                                                  TSD # 14-016 Turbine Building Affiliated Penetrations and Piping                                                                              Revision 00 Turbine Building Affiliated Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                                  Azimuth  Azimuth                      Surface  Space        Int  Void Pen                        U1 Line Ident                                              MARSSIM                                      OD      Wall  Pipe ID Length Length Degrees  Degrees              End        Area  Volume Length  SA  Space No.        Drawings            No.            System      Category        End Sate    Class  From  To        Description      inches Thickness  inches inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 A001  M-162, M-172, M-185 OSW-014-24"    Service Water  Bld to Bld Pen Open Sleeve  Class 3  Aux  TB      Service Water        24    0.688    22.624  36      3      G        16      586      586      17.77    9.42  0.91  1.65 0.267 A002  M-162, M-172, M-185  2FW-027-4"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Aux  TB        Feedwater          4.5    0.237    4.026  36      3      G        16    578.25    578.25      3.16    0.33  0.91  0.29 0.009 A003  M-162, M-172, M-185  OWS-011-2"  Secondary Sample  Bld to Bld Pen Open Sleeve  Class 2  Aux  TB    Secondary Sample      2.375  0.154    2.067  36      3      G        16      586      586      1.62    0.09  0.91  0.15 0.003 A004      M-182, M-163    OSW-013-24"    Service Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Service Water        24    0.688    22.624  36      3      G        23      586      586      17.77    9.42  0.91  1.65 0.267 A005      M-182, M-163      1FW-027-4"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  TB  Aux        Feedwater          4.5    0.237    4.026  36      3      G        23      588      588      3.16    0.33  0.91  0.29 0.009 Main A006      M-165, M-187      OFP-012-10"    Fire Protection Bld to Bld Pen Open Sleeve  Class 3  Stm  Aux      Fire Protection    10.75  0.365    10.02  36      3      H        10      571      571      7.87    1.89  0.91  0.73 0.054 A007  M-165, M-171, M-185  1VN-001-4"    Vents and Drains Bld to Bld Pen Open Sleeve  Class 2  TB  Aux Aux Bld Vents & Drains    4.5    0.237    4.026  36      3      G        13    569.75    569.75      3.16    0.33  0.91  0.29 0.009 A008  M-165, M-171, M-185  2VN-001-4"    Vents and Drains Bld to Bld Pen Open Sleeve  Class 2  TB  Aux Aux Bld Vents & Drains    4.5    0.237    4.026  36      3      G        13    568.75    568.75      3.16    0.33  0.91  0.29 0.009 A009  M-165, M-171, M-185 OWD-031-3    Waste Disposal  Bld to Bld Pen Open Sleeve  Class 1  Aux  TB      Waste Disposal      3.5    0.216    3.068  36      3      G        13    573.25    573.25      2.41    0.20  0.91  0.22 0.006 A010  M-165, M-171, M-185 OSW-056-10"    Service Water  Bld to Bld Pen Open Sleeve  Class 3  Aux  TB      Service Water      10.75  0.365    10.02  36      3      G        14    572.25    572.25      7.87    1.89  0.91  0.73 0.054 A011  M-162, M-172, M-185 OWD-039-2"    Waste Disposal  Bld to Bld Pen Open Sleeve  Class 1  TB  Aux      Waste Disposal      2.375  0.154    2.067  36      3      G        17      574.5    574.5      1.62    0.09  0.91  0.15 0.003 A012      M-165, M-168      OCA-007-3"  Chemical Addition Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Chemical Feed        3.5    0.216    3.068  36      3      G        17      565.5    565.5      2.41    0.20  0.91  0.22 0.006 A013      M-165, M-174      OPW-020-4"    Primary Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Primary Water        4.5    0.237    4.026  36      3      G        17    573.17    573.17      3.16    0.33  0.91  0.29 0.009 A014      M-165, M-174    2SW-002-20"    Service Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Service Water        20    0.594    18.812  36      3      G        17      570.5    570.5      14.77    6.54  0.91  1.37 0.185 A015  M-165, M-171, M-185 OWD-016-6"    Waste Disposal  Bld to Bld Pen Open Sleeve  Class 1  Aux  TB      Waste Disposal      6.625    0.28    6.065  36      3      G        13      571      571      4.76    0.72  0.91  0.44 0.020 See Multiple CTMT to Aux Pens on M-282 and Main  M-662 cover in CTMT A016          M-106            Spare            N/A      Bld to Bld Pen Open Sleeve  Class 3  Aux  Stm        Worksheet          14    0.438    13.124  24      2      H        10      571      571      6.87    2.14  0.61  0.64 0.061 A017      M-182, M-163      OFP-003-10"    Fire Protection Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Fire Protection    10.75  0.365    10.02  36      3      G        23      586.5    586.5      7.87    1.89  0.91  0.73 0.054 Main A018      M-166, M-188      OFP-012-10"    Fire Protection Bld to Bld Pen Open Sleeve  Class 3  Stm  Aux      Fire Protection    10.75  0.365    10.02  36      3      H        30      571      571      7.87    1.89  0.91  0.73 0.054 A019      M-165, M-174      OPW-042-3"    Primary Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Primary Water        3.5    0.216    3.068  36      3      G        17    573.42    573.42      2.41    0.20  0.91  0.22 0.006 A020      M-182, M-166      OVC-071-3"    Vacuum Control  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux    Vacuum Control        3.5    0.216    3.068  36      3      G        24    576.25    576.25      2.41    0.20  0.91  0.22 0.006 A021      M-182,M-166      ODW-003-3"      Demin Water    Bld to Bld Pen Open Sleeve  Class 3  TB  Aux      Demin Water        3.5    0.216    3.068  36      3      G        24    568.75    568.75      2.41    0.20  0.91  0.22 0.006 A022      M-182, M-166      OPW-005-4"    Primary Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux    Line with Flange      4.5    0.237    4.026  36      3      G        24    568.75    568.75      3.16    0.33  0.91  0.29 0.009 A023      M-182, M-166      OWD-20-6"    Waste Disposal  Bld to Bld Pen Open Sleeve  Class 1  TB  Aux      Waste Disposal      6.625    0.28    6.065  36      3      G        24      573      573      4.76    0.72  0.91  0.44 0.020 A024      M-182, M-166    OCD-068-18"      Condensate    Bld to Bld Pen Open Sleeve  Class 3  TB  Aux        Condensate        18    0.562    16.876  36      3      G        24      571      571      13.25    5.30  0.91  1.23 0.150 Service Water Supply A025      M-180, M-166,    OSW-019-36"    Service Water  Bld to Bld Pen Open Sleeve  Class 3  TB  Aux          Header          36      0.75      34.5  36      3      G        23      575      575      27.10  21.21  0.91  2.52 0.600 Service Water Supply to Service Water to                                                Diesel Generator Heat A027  M-102, M-168. M-185 OSW-008-12"        DG Hxs      Bld to Bld Pen Buried Pipe  Class 3  DG  Aux        Exchangers        12.75  0.406    11.938  894  74.5    G        10    554.75    567.5    232.84  57.91  22.71 21.63 1.640 Service Water to A028  M-102, M-168. M-185 OSW-008-12"        DG Hxs      Bld to Bld Pen Buried Pipe  Class 3  DG  Aux Service Water to DG Hxs  12.75  0.406    11.938 932.04  77.67    G        10    553.33    567.5    242.75  60.37  23.67 22.55 1.710 Service Water Supply to Diesel Generator Heat A030      M-102, M-169    OSW-001-12"    Service Water  Bld to Bld Pen Buried Pipe  Class 3  DG  Aux        Exchangers        12.75  0.406    11.938  894  74.5    G        30    554.75    567.5    232.84  57.91  22.71 21.63 1.640 Service Water Supply to Diesel Generator Heat A031      M-102, M-169    OSW-001-12"    Service Water  Bld to Bld Pen Buried Pipe  Class 3  DG  Aux        Exchangers        12.75  0.406    11.938 932.04  77.67    G        30    553.33    567.5    242.75  60.37  23.67 22.55 1.710 See Multiple CTMT to Aux Pens on M-282 and Main  M-662 cover in CTMT A034          M-106            Spare            N/A      Bld to Bld Pen Open Sleeve  Class 3  Aux  Stm        Worksheet          14    0.438    13.124  24      2      H        30      571      571      6.87    1.88  0.61  0.64 0.053 Main  U1 P005      M-281, M-661    1-MS-001-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam          34    1.15625  31.6875  48      4    213      147      579.5    579.5      52.36  54.54  1.22  4.86 1.544 Main  U1 P006      M-281, M-661    1-MS-002-34"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam          34    1.15625  31.6875  48      4    213      147      579.5    579.5      52.36  54.54  1.22  4.86 1.544 1-MS-003-35                                                        Main  U1 P007      M-281, M-661          1/2"        Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam        35.5    1.1875  33.125  48      4    333      27      579.5    579.5      52.36  54.54  1.22  4.86 1.544 1-MS-004-35                                                        Main  U1 P008      M-281, M-661          1/2"        Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam        35.5    1.1875  33.125  48      4    333      27      579.5    579.5      52.36  54.54  1.22  4.86 1.544 Main  U1 P009      M-281, M-661    1-FW-014-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater          16    1.218    13.564  48      4    213      147    584.58    584.58      33.51  22.34  1.22  3.11 0.633 Main  U1 P010      M-281, M-661    1-FW-017-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater          16    1.218    13.564  48      4    213      147    584.58    584.58      33.51  22.34  1.22  3.11 0.633 Main  U1 P011      M-281, M-661    1-FW-011-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater          16    1.218    13.564  48      4    333      27    584.58    584.58      33.51  22.34  1.22  3.11 0.633 Main  U1 P012      M-281, M-661    1-FW-022-16"      Feedwater    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater          16    1.218    13.564  48      4    333      27    586.83    586.83      33.51  22.34  1.22  3.11 0.633 Page 110 of 123
Attachment J                                                                                                TSD # 14-016 Turbine Building Affiliated Penetrations and Piping                                                                            Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                                  Azimuth  Azimuth                      Surface  Space        Int  Void Pen              U1 Line Ident                                        MARSSIM                                    OD      Wall  Pipe ID Length Length Degrees  Degrees              End      Area    Volume Length SA  Space No. Drawings        No.        System  Category        End Sate    Class  From  To        Description    inches Thickness  inches inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters m2    m3 1-BD-007-2                                                  Main  U1      Blowdown Steam P091 M-281, M-661    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.875  0.276    2.323  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1      Blowdown Steam P092 M-281, M-661  1-BD-008-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.375  0.218    1.939  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1      Blowdown Steam P093 M-281, M-661  1-BD-006-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.375  0.218    1.939  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 1-BD-005-2                                                  Main  U1      Blowdown Steam P094 M-281, M-661    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.875  0.276    2.323  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1      Blowdown Steam P095 M-281, M-661  1-BD-007-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.375  0.218    1.939  48    4      213      147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U1      Blowdown Steam P096 M-281, M-661  1-BD-005-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.375  0.218    1.939  48    4      213      147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U1      Blowdown Steam P097 M-281, M-661  1-BD-003-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1D    2.375  0.218    1.939  48    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U1      Blowdown Steam P098 M-281, M-661  1-BD-001-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1B    2.375  0.218    1.939  48    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U1      Steam Generator P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT    Blowdown Sample    0.675  0.065    0.545  48    4      213      147    578.08    578.08    16.76    5.59  1.22  1.56 0.158 Main  U1      Steam Generator P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT    Blowdown Sample    0.675  0.065    0.545  48    4      333      27    578.08    578.08    16.76    5.59  1.22  1.56 0.158 1-BD-003-2                                                  Main  U1    Blowdown (Steam P115 M-282, M-662    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1D)    2.875  0.276    2.323  48    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1    Blowdown (Steam P116 M-282, M-662  1-BD-004-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1D)    2.375  0.218    1.939  48    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1    Blowdown (Steam P117 M-282, M-662  1-BD-002-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1B)    2.375  0.218    1.939  48    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56 0.158 1-BD-001-2                                                  Main  U1    Blowdown (Steam P118 M-282, M-662    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1B)    2.875  0.276    2.323  48    4      333      27    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U1 P127 M-282, M-662  1-MS-018-6"  Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT Steam to Aux FW Pumps  6.625  0.432    5.761  48    4      213      147    578.08    578.08    16.76    5.59  1.22  1.56 0.158 Main  U1 P128 M-282, M-662  1-MS-017-6"  Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT Steam to Aux FW Pumps  6.625  0.432    5.761  48    4      333      27    578.08    578.08    16.76    5.59  1.22  1.56 0.158 Main  U2 P205 M-281, M-661 2-MS-001-34"  Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam        34    1.15625  31.6875  48    4      213      147      579.5    579.5    52.36    54.54  1.22  4.86 1.544 Main  U2 P206 M-281, M-661 2-MS-002-34"  Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam        34    1.15625  31.6875  48    4      213      147      579.5    579.5    52.36    54.54  1.22  4.86 1.544 2-MS-003-35                                                  Main  U2 P207 M-281, M-661    1/2"      Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam      35.5    1.1875  33.125  48    4      333      27      579.5    579.5    52.36    54.54  1.22  4.86 1.544 2-MS-004-35                                                  Main  U2 P208 M-281, M-661    1/2"      Main Steam Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Main Steam      35.5    1.1875  33.125  48    4      333      27      579.5    579.5    52.36    54.54  1.22  4.86 1.544 Main  U2 P209 M-281, M-661 2-FW-014-16"  Feedwater  Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater        16    1.218    13.564  48    4      213      147    584.58    584.58    33.51    22.34  1.22  3.11 0.633 Main  U2 P210 M-281, M-661 2-FW-017-16"  Feedwater  Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater        16    1.218    13.564  48    4      213      147    584.58    584.58    33.51    22.34  1.22  3.11 0.633 Main  U2 P211 M-281, M-661 2-FW-011-16"  Feedwater  Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater        16    1.218    13.564  48    4      333      27    584.58    584.58    33.51    22.34  1.22  3.11 0.633 Main  U2 P212 M-281, M-661 2-FW-022-16"  Feedwater  Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Feedwater        16    1.218    13.564  48    4      333      27    586.83    586.83    33.51    22.34  1.22  3.11 0.633 2-BD-007-2                                                  Main  U2      Blowdown Steam P291 M-281, M-661    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.875  0.276    2.323  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U2      Blowdown Steam P292 M-281, M-661  2-BD-008-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.375  0.218    1.939  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U2      Blowdown Steam P293 M-281, M-661  2-BD-006-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.375  0.218    1.939  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 2-BD-005-2                                                  Main  U2      Blowdown Steam P294 M-281, M-661    1/2"      SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.875  0.276    2.323  48    4      213      147    584.58    584.58    16.76    5.59  1.22  1.56 0.158 Main  U2      Blowdown Steam P295 M-281, M-661  2-BD-007-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1A    2.375  0.218    1.939  48    4      213      147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U2      Blowdown Steam P296 M-281, M-661  2-BD-005-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1C    2.375  0.218    1.939  48    4      213      147    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U2      Blowdown Steam P297 M-281, M-661  2-BD-003-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1D    2.375  0.218    1.939  48    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Main  U2      Blowdown Steam P298 M-281, M-661  2-BD-001-2"  SG Blowdown Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT      Generator 1B    2.375  0.218    1.939  48    4      333      27    580.33    580.33    14.66    4.28  1.22  1.36 0.121 Page 111 of 123
Attachment J                                                                                                          TSD # 14-016 Turbine Building Affiliated Penetrations and Piping                                                                                      Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                                      Azimuth  Azimuth                      Surface  Space        Int  Void Pen                      U1 Line Ident                                            MARSSIM                                          OD    Wall    Pipe ID  Length  Length  Degrees  Degrees              End        Area  Volume Length  SA  Space No.      Drawings            No.          System      Category        End Sate    Class  From  To        Description        inches Thickness inches  inches    Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 Main  U2      Steam Generator P312    M-282, M-662    2-SS-041-3/8"  SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT    Blowdown Sample          0.675  0.065    0.545    48        4      213      147    578.08    578.08      16.76    5.59  1.22  1.56 0.158 Main  U2      Steam Generator P313    M-282, M-662    2-SS-041-3/8"  SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT    Blowdown Sample          0.675  0.065    0.545    48        4      333      27    578.08    578.08      16.76    5.59  1.22  1.56 0.158 2-BD-003-2                                                      Main  U2      Blowdown (Steam P315    M-282, M-662          1/2"      SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Generator 1D)        2.875  0.276    2.323    48        4      333      27    584.58    584.58      16.76    5.59  1.22  1.56 0.158 Main  U2      Blowdown (Steam P316    M-282, M-662      2-BD-004-2"  SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Generator 1D)        2.375  0.218    1.939    48        4      333      27    584.58    584.58      16.76    5.59  1.22  1.56 0.158 Main  U2      Blowdown (Steam P317    M-282, M-662      2-BD-002-2"  SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Generator 1B)        2.375  0.218    1.939    48        4      333      27    584.58    584.58      16.76    5.59  1.22  1.56 0.158 2-BD-001-2                                                      Main  U2      Blowdown (Steam P318    M-282, M-662          1/2"      SG Blowdown    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT        Generator 1B)        2.875  0.276    2.323    48        4      333      27    584.58    584.58      16.76    5.59  1.22  1.56 0.158 Main  U2 P327    M-282, M-662    2-MS-018-6"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT  Steam to Aux FW Pumps      6.625  0.432    5.761    48        4      213      147    578.08    578.08      16.76    5.59  1.22  1.56 0.158 Main  U2 P328    M-282, M-662    2-MS-017-6"    Main Steam    Bld to Bld Pen Open Sleeve  Class 2  Stm CTMT  Steam to Aux FW Pumps      6.625  0.432    5.761    48        4      333      27    578.08    578.08      16.76    5.59  1.22  1.56 0.158 Service Water Return from Diesel Generator T032    M-103 & M-106          0        Service Water  Bld to Bld Pen Buried Pipe  Class 3  TB  DG        Heat Exchangers        16      0.5      15  2201.625 183.4688    G        31    553.83    567.5    720.48  225.15  55.92 66.93 6.376 Service Water Return from to Diesel Generator T033    M-104 & M-106          0        Service Water  Bld to Bld Pen Buried Pipe  Class 3  TB  DG        Heat Exchangers        16      0.5      15    2205    183.75    G        10    553.83    567.5    721.58  225.50  56.01 67.04 6.385 Main T034a        M-106            Spare            N/A      Bld to Bld Pen Open Sleeve  Class 3  DG  Stm        Blank Sleeve          14        0      14      24        2      H        31    587.75    587.75      7.33    2.14  0.61  0.68 0.061 Main T034b        M-106            Spare            N/A      Bld to Bld Pen Open Sleeve  Class 3  DG  Stm        Blank Sleeve          14        0      14      24        2      H        10    587.75    587.75      7.33    2.14  0.61  0.68 0.061 Bld to Yard T035    M-106, M-107          0      Fire Protection      Pen      Pipe in Pen  Class 3  DG  Yard      Fire Protection      10.75  0.365    10.02    36        3      J        5      583.5    584.5      7.87    1.64  0.91  0.73 0.047 Bld to Yard T036    M-106, M-107          0      Fire Protection      Pen      Pipe in Pen  Class 3  DG  Yard      Fire Protection      10.75  0.365    10.02    36        3      J        35      583.5    584.5      7.87    1.64  0.91  0.73 0.047 Diesel Oil Tank Fill Line T068    M-104, M-562      2DO-006-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG  Yard  length to 588' elevation    4.5    0.237    4.026    48        4      G        5    585.25      593      4.22    0.35  1.22  0.39 0.010 T069  M-104, M-562, M-663  2DO-004-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG    TB          Diesel Oil            8        0        0      18      1.5      G        6    585.17    585.17      3.14    0.52  0.46  0.29 0.015 T070  M-104, M-562, M-663  2DO-001-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG    TB          Diesel Oil            8        0        0      18      1.5      G        7    585.17    585.17      3.14    0.52  0.46  0.29 0.015 T070a        M-104            Spare            N/A      Bld to Bld Pen Open Sleeve  Class 3  DG    TB        Open Sleeve            8        0        0      18      1.5      G        8    585.17    585.17      3.14    0.52  0.46  0.29 0.015 T071  M-103, M-214, M-244  1DO-010-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG    TB          Diesel Oil            8        0        0      18      1.5      G        32    585.17    585.17      3.14    0.52  0.46  0.29 0.015 T072  M-103, M-214, M-244  1DO-003-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG    TB          Diesel Oil            8        0        0      18      1.5      G        33    585.17    585.17      3.14    0.52  0.46  0.29 0.015 T073  M-103, M-214, M-244  1DO-002-4"      Diesel Oil  Bld to Bld Pen Open Sleeve  Class 3  DG    TB          Diesel Oil            8        0        0      18      1.5      G        34    585.17    585.17      3.14    0.52  0.46  0.29 0.015 Bld to Yard T074    M-103, M-214      1DO-001-4"      Diesel Oil        Pen      Buried Pipe  Class 3  DG  Yard Diesel Oil see buried pipe  4.5    0.237    4.026    627    52.25    G        35    585.25      593      55.07    4.62  15.93  5.12 0.131 Bld to Yard T091  M-104, M-106 Det B      Spare            N/A          Pen      Open Sleeve  Class 3  TB  Yard Spares Blanks Left Intact  10.75  0.365    10.02    60        5      C        16      585      585      13.12    2.74  1.52  1.22 0.078 Bld to Yard T092  M-104, M-106 Det B      Spare            N/A          Pen      Open Sleeve  Class 3  TB  Yard Spares Blanks Left Intact  12.75  0.406  11.938    60        5      C        16      586      586      15.63    3.89  1.52  1.45 0.110 Bld to Yard T093  M-104, M-106 Det B      Spare            N/A          Pen      Open Sleeve  Class 3  TB  Yard Spares Blanks Left Intact    14    0.438  13.124    60        5      C        16      585      585      17.18    4.70  1.52  1.60 0.133 Bld to Yard                                  Fibercast Makeup Demin T094        M-104              0      Make-Up Demin        Pen      Pipe in Pen  Class 3  TB  Yard    Waste Discharge        8.625  0.322    7.981    48        4      C        17      586      586      8.36    1.39  1.22  0.78 0.039 Bld to Yard                                    Primary Water Storage T095    M-104, M-105          0        Primary Water      Pen      Pipe in Pen  Class 3  TB  Yard            Tank            6.625    0.28    6.065    1420    118.33    C        18    556.75    556.75    187.89  23.74  36.07 17.46 0.672 Bld to Yard T096        M-103              0        Oil Seperator      Pen      Pipe in Pen  Class 3  TB  Yard    Oil Seperator Tank      10.75  0.365    10.02    48        4      C        23      586      586      10.49    2.19  1.22  0.97 0.062 Bld to Yard                                  Fibercast Makeup Demin T097        M-103              0      Make-Up Demin        Pen      Pipe in Pen  Class 3  TB  Yard    Waste Discharge        8.625  0.322    7.981    48        4      C        23      586      586      8.36    1.39  1.22  0.78 0.039 Waste Discharge (WD) from Lake Discharge Bld to Yard                                      Tank to Discharge T098        M-103              0      Waste Discharge      Pen      Pipe in Pen  Class 1  TB  Yard          Tunnel            6.625    0.28    6.065    48        4      C        24      586      586      6.35    0.80  1.22  0.59 0.023 Bld to Yard T099  M-103, M-106 Det B      Spare            N/A          Pen      Pipe in Pen  Class 3  TB  Yard          Spares            10.75  0.365    10.02    60        5      C        24      585      585      13.12    2.74  1.52  1.22 0.078 Bld to Yard T100  M-103, M-106 Det B      Spare            N/A          Pen      Pipe in Pen  Class 3  TB  Yard          Spares            12.75  0.406  11.938    60        5      C        24      586      586      15.63    3.89  1.52  1.45 0.110 Bld to Yard T101  M-103, M-106 Det B      Spare            N/A          Pen      Pipe in Pen  Class 3  TB  Yard          Spares            14    0.438  13.124    60        5      C        24      585      585      17.18    4.70  1.52  1.60 0.133 Page 112 of 123
Attachment J                                                                                                    TSD # 14-016 Turbine Building Affiliated Penetrations and Piping                                                                                Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe                                  Azimuth  Azimuth                      Surface  Space        Int    Void Pen                    U1 Line Ident                                          MARSSIM                                      OD    Wall    Pipe ID Length  Length Degrees  Degrees              End        Area  Volume Length  SA    Space No. Drawings          No.          System      Category      End Sate    Class  From  To        Description        inches Thickness inches  inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2      m3 Bld to Yard                                  Primary Water Supply T102  M-104, M-105          0      Primary Water        Pen    Pipe in Pen  Class 3  TB  Yard      Header to RCP        6.625    0.28    6.065    940  78.33    C        17      586      586      124.38  15.72  23.88 11.56  0.445 Condensate to Alternate M-105 SH 1 & SH 2,                                Bld to Yard                                Feedwater Pumps- Buried T103      M-103              0        Condensate          Pen    Buried Pipe  Class 3  TB  Yard          Section          20    0.594  18.812  2712.59 226.05    B        21      586      586    1020.52  367.34  68.90 94.81  10.402 Bld to Yard T104      M-104              0      Waste Discharge      Pen    Pipe in Pen  Class 1  TB  Yard    Lake Discharge tank    6.625    0.28    6.065    48      4      C        17      586      586      6.35    0.80  1.22  0.59  0.023 Bld to Yard T105      M-103              0        Condensate          Pen    Buried Pipe  Class 3  TB  Yard Condensate Pump Recirc    4.5    0.337    3.826  2652.59 221.05    G        22      560      586    6219.50  14.99  67.38 577.81 0.424 Bld to Yard                                To condensate transfer T106      M-103              0        Condensate          Pen    Buried Pipe  Class 3  TB  Yard    and makeup pumps      12.75  0.406  11.938  251.13  20.93    D        22      560    583.25      65.41  16.27  6.38  6.08  0.461 Page 113 of 123
Attachment J                                                                                                              TSD # 14-016 Turbine Building Affiliated Penetrations and Piping                                                                                        Revision 00 Turbine Building Drains Interior  Void Pipe            Pipe                            Surface  Space            Int  Void Pen                                                                          MARSSIM                                                                  OD    Wall      ID  Length            End      Area  Volume    Length  SA  Space No.            Drawings                System      Category  End Sate      Class  From To                      Description                    inches Thickness inches  Feet  Elevation Elevation    ft2      ft3    meters  m2    m3 T147 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB        U-1 Equip Drain Sump, 6 pipe West Wall        6      0.28    5.44  200      560      557    284.84  32.28    60.96 26.46 0.914 T148 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB        U-1 Equip Drain Sump, 6 pipe North Wall        6      0.28    5.44  100      560      557    142.42  16.14    30.48 13.23 0.457 T149 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB        U-2 Equip Drain Sump, 6 pipe West Wall        6      0.28    5.44  200      560      557    284.84  32.28    60.96 26.46 0.914 T150 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB    Floor Drain Sump, West-most 6 pipe on North Wall    6      0.28    5.44  100      560      557    142.42  16.14    30.48 13.23 0.457 T151 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB    Floor Drain Sump East-most 4 pipe on North Wall    4    0.237    3.526  100      560      557    92.31    6.78    30.48  8.58 0.192 T152 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB      Fire Sump, South-most 4 pipe on West Wall        4    0.237    3.526  150      560      557    138.47  10.17    45.72 12.86 0.288 T153 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB      Fire Sump, North-most 8 pipe on West Wall        8    0.322    7.356  450      560      557    866.61  132.81    137.16 80.51 3.761 T154 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB      Fire Sump, West-most 8 pipe on North Wall        8    0.322    7.356  450      560      557    866.61  132.81    137.16 80.51 3.761 T155 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB      Fire Sump, West-most 10 pipe on North Wall      10    0.365    9.27    80      560      557    194.15  37.50    24.38 18.04 1.062 T156 M-103 , B-454, B-452, B-471, B-473 Aerated Drain  Bld Pen Embedded Pipe  Class 3  TB  TB      Fire Sump, East-most 10 pipe on North Wall      10    0.365    9.27  100      560      557    242.69  46.87    30.48 22.55 1.327 Page 114 of 123
Attachment K                                                                                                    TSD # 14-016 Waste Water Treatment Facility Penetrations and Piping                                                                            Revision 00 Y or Unit X or Unit 1        2                                    Void Pipe                          Azimuth  Azimuth                        Interior  Space                Void MARSSIM                                                      OD    Wall    Pipe ID Length Degrees - Degrees -            End      Surface  Volume Length Int SA Space Pen No. Drawings        System        Category      End Sate      Class  From    To                Description            inches Thickness inches  Feet  minutes  minutes  Elevation Elevation  Area ft2    ft3 meters  m2    m3 W001  B-1003, B-1005  Aerated Drain  Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF  Force Main from Turbine Fire Sump    8.625  0.322    7.981    1      D          2    586.6667  586.6667      2.09    0.35  0.30  0.19  0.010 W002  B-1003, B-1005  Aerated Drain  Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF        Heater bay roof drain lines    6.625    0.28    6.065    1      D          2      585.2    585.2      1.59    0.20  0.30  0.15  0.006 W003  B-1003, B-1005  Sludge Line  Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF  Sludge Line from Outdoor Drying Beds  3.5    0.216    3.068    1      A          6        587      587        0.80    0.05  0.30  0.07  0.001 W004  B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen    Class 3 WWTH  WWTF        Sludge drying bed filtrate      6.625    0.28    6.065    1      A          4        588      588        1.59    0.20  0.30  0.15  0.006 W005  B-1003, B-1005  Water Line    Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF          Water Line from Yard          2.375  0.154    2.067    1      A          3        588      588        0.54    0.02  0.30  0.05  0.001 W006  B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF      Cement Wrapped Ductile Pipe      8.625  0.322    7.981    1      A          2      586.75    586.75      2.09    0.35  0.30  0.19  0.010 W007  B-1003, B-1005    Sanitary    Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF              Sanitary Line              1.9    0.145    1.61    1      A          2        587      587        0.42    0.01  0.30  0.04  0.0004 W008  B-1003, B-1005  Service Air  Bld to Yard Pen Pipe in Pen    Class 3 WWTF  WWTF            Service Air Line            1.9    0.145    1.61    1      A          2      586.75    586.75      0.42    0.01  0.30  0.04  0.0004 Page 115 of 123
Attachment L                                                                                                TSD # 14-016 Crib House Penetrations and Piping                                                                                      Revision 00 Y or Unit X or Unit                              Void Sleeve  Pipe            Pipe        1 Azimuth 2 Azimuth                    Interior  Space        Int  Void Pen                                U1 Line Ident                                            MARSSIM                                      Size    OD    Wall      ID  Length Degrees - Degrees -            End    Surface  Volume Length SA  Space No.          Drawings                No.          System        Category      End Sate    Class    From  To      Description      inches inches Thickness inches  Feet  minutes  minutes  Elevation Elevation Area ft2    ft3 meters m2    m3 Fire Line Below to C001    M-105 SH 1 & 2, M-271      OFP-011-10"  Fire Protection Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard        ForeBay          0    10.75  0.365    10.02  4      AA        111    581.75    581.75    0.87    2.19  1.22  0.08 0.062 C002        M-106, M-272            OSA-002-3"    Station Air  Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard      Station Air        6    3.5    0.216    3.068  4      AA        111      581      581      0.52    0.79  1.22  0.05 0.022 C003        M-106, M-272                0        Control Air    Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard      Control Air        6    2.375  0.154    2.067  4      AA        111      581      581      0.52    0.79  1.22  0.05 0.022 C004        M-106, M-272            OHS-020-3"    Hot Water    Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard  3" Hot Water Supply    6    3.5    0.216    3.068  4      AA        111      581.5    581.5    0.52    0.79  1.22  0.05 0.022 C005        M-106, M-272            OHS-024-3"    Hot Water    Bld to Yard Pen Open Sleeve  Class 3  Crib  Yard  3" Hot Water Return    6    2.375  0.154    2.067  4      AA        111      581.5    581.5    0.52    0.79  1.22  0.05 0.022 C006        M-106, M-272          OMU-031-3"    Filtered Water  Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard    Filtered Water      0    3.5    0.216    3.068  4      AA        111      581.5    581.5    0.27    0.21  1.22  0.02 0.006 Fire Line Below to C007        M-106, M-272          OFP-011-10"  Fire Protection Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard        ForeBay          0    10.75  0.365    10.02  4      AA        111    585.75    585.75    0.87    2.19  1.22  0.08 0.062 M-104 & M-105 sh 1, M-102, M-                                                                                  Service Water Supply C026c            168              OSW-014-48"  Service Water  Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard    Header Crib Pen      0    48    0.625    46.75  4      AA        19      579      579      4.08    47.68  1.22  0.38 1.350 M-104 & M-105 sh 1, M-102, M-                                                                                  Service Water Supply C029c            168              OSW-013-48"  Service Water  Bld to Yard Pen Pipe in Pen  Class 3  Crib  Yard    Header Crib Pen      0    48    0.625    46.75  4      AA        21      579      579      4.08    47.68  1.22  0.38 1.350 Page 116 of 123
Attachment M                                                                                                  TSD # 14-016 Fuel Handling Building Affiliated Penetrations and Piping                                                                                  Revision 00 Y or Unit X or Unit 1        2                                    Void Azimuth  Azimuth                        Interior  Space        Int  Void Pen                            U1 Line Ident                                                        MARSSIM                                      Pipe OD  Wall    Pipe ID Length Degrees - Degrees -              End    Surface  Volume Length  SA  Space No.      Drawings                  No.              System                Category      End Sate      Class    From  To        Description        inches Thickness inches  Feet  minutes  minutes  Elevation  Elevation Area ft2    ft3 meters  m2    m3 M-107 Sh 1, 2 ,3 , M-197,                Spent Fuel Pool - Demin                                                        Spent Fuel Pool -
A029    M-106 Sect K-K            1SF-017-2"          Water            Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Demin Water          2.375  0.154    2.067  89.58    R        24      570.58    583.33    48.48    2.09  27.31 4.50  0.059 M-107 Sh 1, 2 ,3 , M-197, A036    M-106 Sect K-K          1SI-012-24"      Safety Injection      Bld to Yard Pen Buried Pipe  Unimpacted  Aux SFB      Safety Injection        24    0.688  22.624  70.11    R        24        570        0      415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-197,                Spent Fuel Pit Tell Tale A037    M-106 Sect K-K        1AD-149-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  30.75    R        24        571    Unknown    4.05    0.14  2.93 0.38  0.004 M-107 Sh 1, 2 ,3 , M-197,                Spent Fuel Pit Tell Tale A038    M-106 Sect K-K        1AD-148-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  30.75    R        24        571    Unknown    11.68    0.39  8.44 1.08  0.011 M-107 Sh 1, 2 ,3 , M-197,                Spent Fuel Pit Tell Tale A039    M-106 Sect K-K        1AD-147-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  17.75    R        24        571    Unknown    7.48    0.25  5.41 0.70  0.007 M-107 Sh 1, 2 ,3 , M-197, A040    M-106 Sect K-K          1AD-146-4"        Aerated Drain        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB      Aerated Drain        4.5    0.237    4.026  124.52    R        24      569.33      584    131.25  11.01  37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M-197, A041    M-106 Sect K-K        1SA-014-1 1/2"      Station Air          Bld to Yard Pen Buried Pipe    Class 3  Aux SFB        Service Air          1.9    0.145    1.61  94.17    R        24      569.33      583      39.69    1.33  28.70 3.69  0.038 M-107 Sh 1, 2 ,3 , M-197, A042    M-106 Sect K-K          ODW-100-2"        Demin Water          Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Demin Water          2.375  0.154    2.067  63.55    R        24      570.58      484      34.39    1.48  19.37 3.19  0.042 M-107 Sh 1, 2 ,3 , M-197, A043    M-106 Sect K-K          OFP-016-4"      Fire Protection        Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Fire Protection        4.5    0.237    4.026  91.08    R        24      570.58      584      96.00    8.05  27.76 8.92  0.228 M-107 Sh 1, 2 ,3 , M-197, A044    M-106 Sect K-K          1SW-181-2"        Service Water        Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Service Water        2.375  0.154    2.067  92.58    R        24      570.58      584      50.10    2.16  28.22 4.65  0.061 M-107 Sh 1, 2 ,3 , M-197, A046    M-106 Sect K-K        01A-004-1 1/2"    Instrument Air        Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Instrument Air        1.9    0.145    1.61    94      R        24      570.58      584      39.62    1.33  28.65 3.68  0.038 M-107 Sh 1, 2 ,3 , M-197, A047    M-106 Sect K-K            1SF-022-3"      Spent Fuel Pool        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB  Spent Fuel Pit Cooling    3.5    0.216    3.068  84.42    R        24      569.33      583      67.80    4.33  25.73 6.30  0.123 M-107 Sh 1, 2 ,3 , M-197, A048    M-106 Sect K-K            1SF-008-2"      Spent Fuel Pool        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB  Spent Fuel Pit Cooling  2.375  0.154    2.067    86      R        24      569.33      583      46.54    2.00  26.21 4.32  0.057 M-107 Sh 1, 2 ,3 , M-197, A049    M-106 Sect K-K          1CC-078-10"    Component Cooling        Bld to Yard Pen Buried Pipe    Class 2  Aux SFB    Component Cooling      10.75  0.365    10.02  128.08    R        24      570.58      584    335.99  70.14  39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M-197, A050    M-106 Sect K-K          1CC-080-10"    Component Cooling        Bld to Yard Pen Buried Pipe    Class 2  Aux SFB    Component Cooling      10.75  0.365    10.02  130.92    R        24      570.58      584    343.42  71.69  39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M-260, A051    M-106 Sect K-K          2SI-012-24"      Safety Injection      Bld to Yard Pen Buried Pipe  Unimpacted  Aux SFB      Safety Injection        24    0.688  22.624  70.11    R        16        570        573    415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-260,                Spent Fuel Pit Tell Tale A052    M-106 Sect K-K        2AD-149-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  30.75    R        16        571    Unknown    4.05    0.14  2.93 0.38  0.004 M-107 Sh 1, 2 ,3 , M-260,                Spent Fuel Pit Tell Tale A053    M-106 Sect K-K        2AD-148-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  30.75    R        16        571    Unknown    11.68    0.39  8.44 1.08  0.011 M-107 Sh 1, 2 ,3 , M-260,                Spent Fuel Pit Tell Tale A054    M-106 Sect K-K        2AD-147-1 1/2"          Lines            Bld to Bld Pen  Buried Pipe    Class 1  Aux SFB      Aerated Drain        1.9    0.145    1.61  17.75    R        16        571    Unknown    7.48    0.25  5.41 0.70  0.007 M-107 Sh 1, 2 ,3 , M-260, A055    M-106 Sect K-K            2SF-008-2"      Spent Fuel Pool        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB  Spent Fuel Pit Cooling  2.375  0.154    2.067  113.25    R        16      569.33      583      61.28    2.64  34.52 5.69  0.075 M-107 Sh 1, 2 ,3 , M-260, A056    M-106 Sect K-K            2SF-022-3"      Spent Fuel Pool        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB  Spent Fuel Pit Cooling    3.5    0.216    3.068    111      R        16      569.33      583      89.16    5.70  33.83 8.28  0.161 M-107 Sh 1, 2 ,3 , M-260, A057    M-106 Sect K-K            0SF-012-3"      Spent Fuel Pool        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB  Spent Fuel Pit Cooling    3.5    0.216    3.068  109.5    R        16      569.33      583      87.95    5.62  33.38 8.17  0.159 M-107 Sh 1, 2 ,3 , M-260,                                                                                              Decon Pad Drain to A058    M-106 Sect K-K          0CT-061-2"        Waste Drain          Bld to Yard Pen Buried Pipe    Class 1  Aux SFB    Chem Drain Tank        2.375  0.154    2.067  89.75    R        16      569.33      583      48.57    2.09  27.36 4.51  0.059 M-107 Sh 1, 2 ,3 , M-260, A059    M-106 Sect K-K          2CC-078-10"    Component Cooling        Bld to Yard Pen Buried Pipe    Class 2  Aux SFB    Component Cooling      10.75  0.365    10.02  108.58    R        16      570.58      584    284.84  59.46  33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M-260, A060    M-106 Sect K-K          2CC-080-10"    Component Cooling        Bld to Yard Pen Buried Pipe    Class 2  Aux SFB    Component Cooling      10.75  0.365    10.02  106.42    R        16      570.58      584    279.16  58.27  32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M-260, A061    M-106 Sect K-K          2DW-008-3"        Demin Water          Bld to Yard Pen Buried Pipe    Class 3  Aux SFB    Demineralized Water      3.5    0.216    3.068  128.25    R        16      569.33      583    103.01    6.58  39.09 9.57  0.186 M-107 Sh 1, 2 ,3 , M-197, A062    M-106 Sect K-K          2AD-146-4"        Aerated Drain        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB      Aerated Drain        4.5    0.237    4.026  129.67    R        16      570.58      584    136.67  11.46  39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M-260, A063    M-106 Sect K-K          2DW-014-3"        Demin Water          Bld to Yard Pen Buried Pipe    Class 3  Aux SFB    Demineralized Water      3.5    0.216    3.068  126.67    R        16      570.58      583    101.74    6.50  38.61 9.45  0.184 M-107 Sh 1, 2 ,3 , M-260, A064    M-106 Sect K-K        OWD-059-2 1/2"    Waste Disposal        Bld to Yard Pen Buried Pipe    Class 1  Aux SFB      Waste Disposal        2.875  0.203    2.469  123.67    R        16      570.58      584      79.94    4.11  37.69 7.43  0.116 M-107 Sh 1, 2 ,3 , M-260, A065    M-106 Sect K-K          2SW-243-3"        Service Water        Bld to Yard Pen Buried Pipe    Class 3  Aux SFB      Service Water        3.5    0.216    3.068  124.67    R        16      569.33      584    100.13    6.40  38.00 9.30  0.181 M-107 Sh 1, 2 ,3 , M-260, A066    M-106 Sect K-K        2SA-012-1 1/2"      Station Air          Bld to Yard Pen Buried Pipe    Class 3  Aux SFB        Service Air          1.9    0.145    1.61  124.5    R        16      569.33      583      52.48    1.76  37.95 4.88  0.050 Page 117 of 123
Attachment M                                                                                            TSD # 14-016 Fuel Handling Building Affiliated Penetrations and Piping                                                                        Revision 00 Y or Unit X or Unit 1        2                                    Void Azimuth  Azimuth                        Interior  Space        Int  Void Pen                            U1 Line Ident                                  MARSSIM                                Pipe OD  Wall    Pipe ID Length Degrees - Degrees -              End    Surface  Volume Length SA  Space No.        Drawings              No.      System    Category    End Sate    Class  From  To      Description      inches Thickness inches  Feet  minutes  minutes  Elevation  Elevation Area ft2  ft3  meters m2    m3 M-281, B-213 Detail 4, M-                                        Pipe in            U1 P049          661                  0      Cavity  Bld to Bld Pen  Sleeve    Class 1 CTMT SFB    Fuel Transfer Tube    24    0.688  22.624  8.21    90        270    578.54    578.5417  48.62    22.92  2.50  4.52 0.649 M-281, B-213 Detail 4, M-                                        Pipe in            U2 P249          661                  0      Cavity  Bld to Bld Pen  Sleeve    Class 1 CTMT SFB    Fuel Transfer Tube    24    0.688  22.624  8.21    90        270    578.54    578.5417  48.62    22.92  2.50  4.52 0.649 Page 118 of 123
Attachment N                                                                                                  TSD # 14-016 Buried Pipe List                                                                                              Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe            Pipe        Azimuth  Azimuth                      Surface  Space        Int  Void Pen                                                                                            MARSSIM                                              OD    Wall      ID  Length Degrees  Degrees              End      Area  Volume Length  SA  Space No.      Drawings        Line Ident No.          System            Category      End Sate    Class    From  To          Description          inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3 meters  m2    m3 Service Water Supply to Diesel A027 M-102, M-168. M-185    OSW-008-12"  Service Water to DG Hxs  Bld to Bld Pen Buried Pipe  Class 3  DG  Aux  Generator Heat Exchangers    12.75  0.406  11.938  74.5    G        10    554.75    567.5    232.84  57.91  22.71 21.63 1.640 A028 M-102, M-168. M-185    OSW-008-12"  Service Water to DG Hxs  Bld to Bld Pen Buried Pipe  Class 3  DG  Aux    Service Water to DG Hxs      12.75  0.406  11.938  77.67    G        10    553.33    567.5    242.75  60.37  23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pool - Demin    Bld to Yard A029 197, M-106 Sect K-K    1SF-017-2"            Water                Pen      Buried Pipe  Class 3  Aux SFB Spent Fuel Pool - Demin Water  2.375  0.154    2.067  89.58    R        24    570.58    583.33    48.48    2.09  27.31  4.50 0.059 Service Water Supply to Diesel A030    M-102, M-169        OSW-001-12"        Service Water      Bld to Bld Pen Buried Pipe  Class 3  DG  Aux  Generator Heat Exchangers    12.75  0.406  11.938  74.5    G        30    554.75    567.5    232.84  57.91  22.71 21.63 1.640 Service Water Supply to Diesel A031    M-102, M-169        OSW-001-12"        Service Water      Bld to Bld Pen Buried Pipe  Class 3  DG  Aux  Generator Heat Exchangers    12.75  0.406  11.938  77.67    G        30    553.33    567.5    242.75  60.37  23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A036 197, M-106 Sect K-K    1SI-012-24"      Safety Injection          Pen      Buried Pipe Unimpacted  Aux SFB        Safety Injection          24    0.688  22.624  70.11    R        24      570        0      415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A037 197, M-106 Sect K-K  1AD-149-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  30.75    R        24      571    Unknown    4.05    0.14  2.93  0.38 0.004 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A038 197, M-106 Sect K-K  1AD-148-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  30.75    R        24      571    Unknown    11.68    0.39  8.44  1.08 0.011 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A039 197, M-106 Sect K-K  1AD-147-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  17.75    R        24      571    Unknown    7.48    0.25  5.41  0.70 0.007 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A040 197, M-106 Sect K-K    1AD-146-4"        Aerated Drain            Pen      Buried Pipe  Class 1  Aux SFB        Aerated Drain            4.5    0.237    4.026 124.52    R        24    569.33      584    131.25  11.01  37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A041 197, M-106 Sect K-K  1SA-014-1 1/2"        Station Air            Pen      Buried Pipe  Class 3  Aux SFB          Service Air            1.9    0.145    1.61  94.17    R        24    569.33      583      39.69    1.33  28.70  3.69 0.038 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A042 197, M-106 Sect K-K    ODW-100-2"          Demin Water              Pen      Buried Pipe  Class 3  Aux SFB          Demin Water            2.375  0.154    2.067  63.55    R        24    570.58      484      34.39    1.48  19.37  3.19 0.042 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A043 197, M-106 Sect K-K    OFP-016-4"        Fire Protection          Pen      Buried Pipe  Class 3  Aux SFB        Fire Protection          4.5    0.237    4.026  91.08    R        24    570.58      584      96.00    8.05  27.76  8.92 0.228 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A044 197, M-106 Sect K-K    1SW-181-2"        Service Water            Pen      Buried Pipe  Class 3  Aux SFB        Service Water          2.375  0.154    2.067  92.58    R        24    570.58      584      50.10    2.16  28.22  4.65 0.061 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A046 197, M-106 Sect K-K  01A-004-1 1/2"      Instrument Air            Pen      Buried Pipe  Class 3  Aux SFB        Instrument Air          1.9    0.145    1.61  94      R        24    570.58      584      39.62    1.33  28.65  3.68 0.038 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A047 197, M-106 Sect K-K    1SF-022-3"      Spent Fuel Pool            Pen      Buried Pipe  Class 1  Aux SFB    Spent Fuel Pit Cooling      3.5    0.216    3.068  84.42    R        24    569.33      583      67.80    4.33  25.73  6.30 0.123 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A048 197, M-106 Sect K-K    1SF-008-2"      Spent Fuel Pool            Pen      Buried Pipe  Class 1  Aux SFB    Spent Fuel Pit Cooling      2.375  0.154    2.067  86      R        24    569.33      583      46.54    2.00  26.21  4.32 0.057 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A049 197, M-106 Sect K-K    1CC-078-10"    Component Cooling            Pen      Buried Pipe  Class 2  Aux SFB      Component Cooling          10.75  0.365    10.02 128.08    R        24    570.58      584    335.99  70.14  39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A050 197, M-106 Sect K-K    1CC-080-10"    Component Cooling            Pen      Buried Pipe  Class 2  Aux SFB      Component Cooling          10.75  0.365    10.02 130.92    R        24    570.58      584    343.42  71.69  39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A051 260, M-106 Sect K-K    2SI-012-24"      Safety Injection          Pen      Buried Pipe Unimpacted  Aux SFB        Safety Injection          24    0.688  22.624  70.11    R        16      570      573    415.27  195.73  21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A052 260, M-106 Sect K-K  2AD-149-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  30.75    R        16      571    Unknown    4.05    0.14  2.93  0.38 0.004 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A053 260, M-106 Sect K-K  2AD-148-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  30.75    R        16      571    Unknown    11.68    0.39  8.44  1.08 0.011 M-107 Sh 1, 2 ,3 , M-                Spent Fuel Pit Tell Tale A054 260, M-106 Sect K-K  2AD-147-1 1/2"          Lines          Bld to Bld Pen Buried Pipe  Class 1  Aux SFB        Aerated Drain            1.9    0.145    1.61  17.75    R        16      571    Unknown    7.48    0.25  5.41  0.70 0.007 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A055 260, M-106 Sect K-K    2SF-008-2"      Spent Fuel Pool            Pen      Buried Pipe  Class 1  Aux SFB    Spent Fuel Pit Cooling      2.375  0.154    2.067 113.25    R        16    569.33      583      61.28    2.64  34.52  5.69 0.075 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A056 260, M-106 Sect K-K    2SF-022-3"      Spent Fuel Pool            Pen      Buried Pipe  Class 1  Aux SFB    Spent Fuel Pit Cooling      3.5    0.216    3.068  111    R        16    569.33      583      89.16    5.70  33.83  8.28 0.161 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A057 260, M-106 Sect K-K    0SF-012-3"      Spent Fuel Pool            Pen      Buried Pipe  Class 1  Aux SFB    Spent Fuel Pit Cooling      3.5    0.216    3.068  109.5    R        16    569.33      583      87.95    5.62  33.38  8.17 0.159 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard                                  Decon Pad Drain to Chem Drain A058 260, M-106 Sect K-K    0CT-061-2"          Waste Drain            Pen      Buried Pipe  Class 1  Aux SFB              Tank              2.375  0.154    2.067  89.75    R        16    569.33      583      48.57    2.09  27.36  4.51 0.059 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A059 260, M-106 Sect K-K    2CC-078-10"    Component Cooling            Pen      Buried Pipe  Class 2  Aux SFB      Component Cooling          10.75  0.365    10.02 108.58    R        16    570.58      584    284.84  59.46  33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A060 260, M-106 Sect K-K    2CC-080-10"    Component Cooling            Pen      Buried Pipe  Class 2  Aux SFB      Component Cooling          10.75  0.365    10.02 106.42    R        16    570.58      584    279.16  58.27  32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A061 260, M-106 Sect K-K    2DW-008-3"          Demin Water              Pen      Buried Pipe  Class 3  Aux SFB      Demineralized Water        3.5    0.216    3.068 128.25    R        16    569.33      583    103.01    6.58  39.09  9.57 0.186 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A062 197, M-106 Sect K-K    2AD-146-4"        Aerated Drain            Pen      Buried Pipe  Class 1  Aux SFB        Aerated Drain            4.5    0.237    4.026 129.67    R        16    570.58      584    136.67  11.46  39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M-                                          Bld to Yard A063 260, M-106 Sect K-K    2DW-014-3"          Demin Water              Pen      Buried Pipe  Class 3  Aux SFB      Demineralized Water        3.5    0.216    3.068 126.67    R        16    570.58      583    101.74    6.50  38.61  9.45 0.184 Page 119 of 123
Attachment N                                                                                                          TSD # 14-016 Buried Pipe List                                                                                                      Revision 00 Y or    X or Unit 1  Unit 2                      Interior  Void Pipe            Pipe        Azimuth  Azimuth                      Surface  Space          Int    Void Pen                                                                                              MARSSIM                                                    OD    Wall      ID  Length Degrees  Degrees              End      Area  Volume  Length  SA    Space No.      Drawings          Line Ident No.            System            Category      End Sate    Class  From    To                Description            inches Thickness inches  Feet  -minutes -minutes Elevation Elevation    ft2      ft3  meters  m2      m3 M-107 Sh 1, 2 ,3 , M-                                              Bld to Yard A064  260, M-106 Sect K-K  OWD-059-2 1/2"        Waste Disposal            Pen      Buried Pipe  Class 1  Aux  SFB              Waste Disposal            2.875  0.203    2.469 123.67    R        16    570.58      584      79.94    4.11  37.69  7.43  0.116 M-107 Sh 1, 2 ,3 , M-                                              Bld to Yard A065  260, M-106 Sect K-K    2SW-243-3"            Service Water            Pen      Buried Pipe  Class 3  Aux  SFB              Service Water              3.5    0.216    3.068 124.67    R        16    569.33      584    100.13    6.40  38.00  9.30  0.181 M-107 Sh 1, 2 ,3 , M-                                              Bld to Yard A066  260, M-106 Sect K-K  2SA-012-1 1/2"          Station Air            Pen      Buried Pipe  Class 3  Aux  SFB                Service Air              1.9    0.145    1.61  124.5    R        16    569.33      583      52.48    1.76  37.95  4.88  0.050 M-104 & M-105 sh 1,                  Service Water Supply Header  Bld to Yard                                      Service Water Supply Header Aux C026    M-102, M-168        OSW-014-48"              Under TB              Pen      Buried Pipe  Class 3  Aux  Yard            Pen to Under TB            48    0.625    46.75  171.5    G        19    549.67  549.6667  174.92  2044.35  52.27 16.25  57.889 M-105 SH 1 & 2, M-                                                Bld to Yard                                      Service Water Supply Header at TB C026a        272            OSW-014-48"    Service Water Supply Header      Pen      Buried Pipe  Class 3  Aux  Yard            Foundation Exit            48    0.625    46.75  37.33    C        19      579    549.6667    38.08  445.03  11.38  3.54  12.602 M-104 & M-105 sh 1,                  Service Water Supply Header  Bld to Yard                                      Service Water Supply Header Aux C029    M-102, M-168        OSW-013-48"              Under TB              Pen      Buried Pipe  Class 3  Aux  Yard            Pen to Under TB            48    0.625    46.75  171.5    G        21    549.67  549.6667  174.92  2044.35  52.27 16.25  57.889 M-105 SH 1 & 2, M-                                                Bld to Yard                                      Service Water Supply Header at TB C029a        272            OSW-013-48"    Service Water Supply Header      Pen      Buried Pipe  Class 3  Aux  Yard            Foundation Exit            48    0.625    46.75  37.33    C        21      579    549.6667    38.08  445.03  11.38  3.54  12.602 Service Water Return from Diesel T032    M-103 & M-106              0                Service Water      Bld to Bld Pen Buried Pipe  Class 3  TB    DG        Generator Heat Exchangers        16      0.5      15  183.47    G        31    553.83    567.5    720.48  225.15  55.92 66.93  6.376 Service Water Return from to T033    M-104 & M-106              0                Service Water      Bld to Bld Pen Buried Pipe  Class 3  TB    DG    Diesel Generator Heat Exchangers    16      0.5      15  183.75    G        10    553.83    567.5    721.58  225.50  56.01 67.04  6.385 Bld to Yard T074    M-103, M-214        1DO-001-4"              Diesel Oil            Pen      Buried Pipe  Class 3  DG    Yard        Diesel Oil see buried pipe      4.5    0.237    4.026  52.25    G        35    585.25      593      55.07    4.62  15.93  5.12  0.131 M-105 SH 1 & SH 2,                                                Bld to Yard                                      Condensate to Alternate Feedwater T103        M-103                  0                Condensate              Pen      Buried Pipe  Class 3  TB    Yard        Pumps- Buried Section          20    0.594  18.812 226.05    B        21      586      586    1020.52  367.34  68.90 94.81  10.402 Bld to Yard T105        M-103                  0                Condensate              Pen      Buried Pipe  Class 3  TB    Yard        Condensate Pump Recirc          4.5    0.337    3.826 221.05    G        22      560      586    6219.50    14.99  67.38 577.81  0.424 Bld to Yard                                      To condensate transfer and makeup T106        M-103                  0                Condensate              Pen      Buried Pipe  Class 3  TB    Yard                pumps                12.75  0.406  11.938  20.93    D        22      560    583.25    65.41    16.27  6.38  6.08  0.461 U2 Disch T139        M-100                  0            Circ Water Discharge    Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay Unit 2 Circ Water Ice Melting Pipe  144    1.25    141.5  80.42  GG        31      569      569    2978.98  8781.78  24.51 276.76 248.672 U2 Disch T140        M-100                  0            Circ Water Discharge    Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay Unit 2 Circ Water Ice Melting Pipe  96        1      94    25    GG        31      569      569    615.23  1204.82  7.62  57.16  34.117 Disch T141        M-100                  0            Circ Water Discharge    Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay Unit 1 Circ Water Ice Melting Pipe  144    1.25    141.5  80.42  GG        31      569      569    2978.98  8781.78  24.51 276.76 248.672 Disch T142        M-100                  0            Circ Water Discharge    Bld to Bld Pen Buried Pipe  Class 3  Tun  Forebay Unit 1 Circ Water Ice Melting Pipe  96        1      94    25    GG        31      569      569    615.23  1204.82  7.62  57.16  34.117 Page 120 of 123
Attachment O                                                                                                    TSD # 14-016 Circulating Water Intake Inventory List                                                                                      Revision 00 Y or Unit X or Unit 1        2                                    Void Pipe            Pipe        Azimuth  Azimuth                      Interior  Space          Int    Void Pen                                                                              MARSSIM                                                        OD    Wall      ID  Length Degrees - Degrees -            End    Surface  Volume  Length  SA    Space No.          Drawings                System        Category      End Sate      Class    From    To              Description              inches Thickness inches  Feet  minutes  minutes  Elevation Elevation Area ft2    ft3  meters  m2      m3 Unit 2 Blind Flange Man Entry to Circ T083  M-780, M-100, M-101, M-104  Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Water Intake                36    0.375    35.25    9      D        6        564      564      83.06    60.99  2.74  7.72  1.73 Unit 2 Blind Flange Man Entry to Circ T085  M-780, M-100, M-101, M-104  Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Water Intake                36    0.375    35.25    9      D        13        564      564      83.06    60.99  2.74  7.72  1.73 M-15, M-100, M-101, B-64, M-                                                                      Unit 1 Blind Flange Man Enttry to Circ T087              103              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Water Intake                36    0.375    35.25    9      D        27        564      564      83.06    60.99  2.74  7.72  1.73 M-15, M-100, M-101, B-62, M-                                                                      Unit 1 Blind Flange Man Enttry to Circ T088              103              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Water Intake                36    0.375    35.25    9      D        34        564      564      83.06    60.99  2.74  7.72  1.73 Unit 1 Circ water supply pipe to T109            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        34        564      564    291.38  643.47  3.20  27.07  18.22 Unit 1 Circ water supply pipe to T110            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        34        572      572    291.38  643.47  3.20  27.07  18.22 T111          M-100, B-61          Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib        Unit 1 Circ water pipe          144    1.25    141.5 45.625    E        34        564      564    1760.39  5089.54  13.91 163.55 144.12 T111b        M-100, B-61          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          144    1.25    141.5  22.5      E        34        564      564    833.50  2457.10  6.86  77.44  69.58 T112            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib        Unit 1 Circ water pipe          144    1.25    141.5  124.2    E        34        564      564    4600.94  13563.19  37.86 427.44 384.07 Unit 1 Circ water pipe 12' to 17' T113            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              expansion                  174      1.5    171    9      E        34        558      558    402.91  1435.36  2.74  37.43  40.64 T114            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          204      1.5    201  94.67    B        31        558      558    4981.52  20860.11  28.85 462.80 590.69 T115        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          108      1      106  14.25    AA        20        558      558    499.12  1434.84  4.34  46.37  40.63 T116        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          108      1      106  19.5    AA        22        558      558    541.14  1195.02  5.94  50.27  33.84 T117        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          108      1      106  14.25    AA        24        558      558    395.45  873.28  4.34  36.74  24.73 T118            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          114      1      112  8.25    AA        26        558      558    241.90  564.44  2.51  22.47  15.98 T119            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 1 Circ water pipe          120      1      118    14      AA        26        558      558    432.49  1063.21  4.27  40.18  30.11 Unit 1 Circ water supply pipe to T120            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        26        572      572    291.38  643.47  3.20  27.07  18.22 Unit 1 Circ water supply pipe to T121            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2,5      E        26        572      572    291.38  643.47  3.20  27.07  18.22 Unit 2 Circ water supply pipe to T122          M-100, B-61          Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  144    1.25    141.5  45.63    E        6        564      564    1760.39  5089.54  13.91 163.55 144.12 Unit 2 Circ water supply pipe to T122b        M-100, B-61          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib              Condenser                  144    1.25    141.5  83.5      E        6        564      564    1760.39  5089.54  25.45 163.55 144.12 Unit 2 Circ water supply pipe to T123            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        6        572      572    291.38  643.47  3.20  27.07  18.22 Unit 2 Circ water supply pipe to T123a          M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        6        572      572    291.38  643.47  3.20  27.07  18.22 T124          M-100, B-61          Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib        Unit 2 Circ water pipe          144    1.25    141.5  45.63    E        6        564      564    1760.39  5089.54  13.91 163.55 144.12 T124b        M-100, B-61          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          144    1.25    141.5  22.5      E        6        564      564    1760.39  5089.54  6.86  163.55 144.12 Unit 2 Circ water pipe 12' to 17' T125            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              expansion                  144    1.25    141.5  124.2    E        6        564      564    4600.94  13563.19  37.86 427.44 384.07 Unit 2 Circ water pipe 12' to 17' T126            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              expansion                  174      1.5    171    9      B        8        558      558    402.91  1435.36  2.74  37.43  40.64 T127            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          204      1.5    201  94.67    A        12        558      558    4981.52  20860.11  28.85 462.80 590.69 T128        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          108      1      106  14.25    AA        20        558      558    499.12  1434.84  4.34  46.37  40.63 T129        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          108      1      106  19.5    AA        18        558      558    541.14  1195.02  5.94  50.27  33.84 T130        M-100, M-272          Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          108      1      106  14.25    AA        16        558      558    395.45  873.28  4.34  36.74  24.73 T131            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          114      1      112  8.25    AA        14        558      558    241.90  564.44  2.51  22.47  15.98 T132            M-100              Circ Water Intake Bld to Bld Pen  Buried Pipe    Class 3  TB    Crib        Unit 2 Circ water pipe          120      1      118    14      AA        14        558      558    432.49  1063.21  4.27  40.18  30.11 Unit 2 Circ water supply pipe to T133            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        14        572      572    291.38  643.47  3.20  27.07  18.22 Unit 2 Circ water supply pipe to T134            M-100              Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib              Condenser                  108      1      106    2.5      E        14        572      572    291.38  643.47  3.20  27.07  18.22 T143          M-100, B-61          Circ Water Intake Bld to Bld Pen Embedded Pipe  Class 3  TB    Crib        Unit 2 Circ water pipe          144    1.25    141.5  45.63    E        14        564      564    1760.39  5089.54  13.91 163.55 144.12 Page 121 of 123
Attachment O                                                                                              TSD # 14-016 Circulating Water Intake Inventory List                                                                                Revision 00 Y or Unit X or Unit 1        2                                  Void Pipe            Pipe        Azimuth  Azimuth                      Interior  Space          Int    Void Pen                                                          MARSSIM                                                  OD    Wall      ID  Length Degrees - Degrees -            End    Surface  Volume  Length  SA    Space No. Drawings        System        Category      End Sate    Class    From    To            Description          inches Thickness inches  Feet  minutes  minutes  Elevation Elevation Area ft2  ft3  meters  m2      m3 T143b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3  TB    Crib      Unit 2 Circ water pipe      144    1.25    141.5  83.5      E        14        564      564    1760.39  5089.54  25.45 163.55 144.12 T144  M-2, B-49  Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake    Circ Water Intake to Forebay  192    0.75    190.5  50      GG        16        558      558    2493.64  9896.63  15.24 231.67 280.24 T145  M-2, B-49  Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake    Circ Water Intake to Forebay  192    0.75    190.5  50      GG        20        558      558    2493.64  9896.63  15.24 231.67 280.24 T146  M-2, B-49  Circ Water Intake Bld to Bld Pen Buried Pipe  Class 3 Forebay Lake    Circ Water Intake to Forebay  192    0.75    190.5  50      GG        24        558      558    2493.64  9896.63  15.24 231.67 280.24 Page 122 of 123
Attachment P                                                                                                          TSD # 14-016 Circulating Water Discharge Pipe Inventory                                                                                          Revision 00 Y or    X or Unit 1  Unit 2                                Void Pipe            Pipe                    Azimuth  Azimuth                      Interior  Space                Void Pen                                                                        MARSSIM                                                          OD    Wall      ID  Length Void Space  Degrees  Degrees              End    Surface  Volume  Length  Int  Space No. Drawings              System          Category      End Sate    Class  From      To                  Description            inches Thickness inches  Feet  Volume in3 -minutes -minutes Elevation Elevation Area ft2    ft3  meters SA m2    m3 T075 M-104, B-68, B-100  Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun Unit 2 Stand Pipe                    48    0.625    46.75  38.60  795132.72    F        9      588      553    472.45  460.15  11.77 43.89  13.03 T076 M-103, B-62, B-100  Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun Unit 1 Stand Pipe                    48    0.625    46.75  38.60  795132.72    F        31      588      553    472.45  460.15  11.77 43.89  13.03 M-15, M-101, B-                                                                                  Unit 2 Circulating Water Discharge T077    100, M-104      Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun from Condenser to Discharge Tunnel  145.5    0.75    144    5    977160.98    E        9      562      557    188.50  565.49  1.52  17.51  16.01 M-15, M-101, B-                                                                                  Unit 2 Circulating Water Discharge T078    100, M-104      Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun from Condenser to Discharge Tunnel  145.5    0.75    144    5    977160.98    E        9      562      557    188.50  565.49  1.52  17.51  16.01 Unit 2 Service Water Return to T079 B-66, B-68, M-104      Service Water    Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun Discharge Tunnel                      48    0.625    46.75 199.92 4117971.72    E        9    553.83      560    2446.80  2383.09  60.93 227.32 67.48 M-780, M-101, M-                                                                                  Unit 1 Circulating Water Discharge T080        103          Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun from Condenser to Discharge Tunnel  145.5    0.75    144    5    977160.98    E        31      562      557    188.50  565.49  1.52  17.51  16.01 M-780, M-101, M-                                                                                  Unit 1 Circulating Water Discharge T081        103          Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun from Condenser to Discharge Tunnel  145.5    0.75    144    5    977160.98    E        31      562      557    188.50  565.49  1.52  17.51  16.01 Unit 1 Service Water Return to T082 B-62, B-64, M-103      Service Water    Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun Discharge Tunnel                      48    0.625    46.75 199.92 4117971.72    E        33    553.83      560    2446.80  2383.09  60.93 227.32 67.48 M-780, B-68, B-100,                                                                              Unit 2 Circ Water Discharge Stand T084    B-68, M-104      Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun Pipe                                  36    0.375    35.25  29.5  345470.83    D        9      588      558.5    272.24  199.93  8.99  25.29  5.66 M-15, B-62, B-100,                                                                                Unit 1 Circ Water Discharge Stand T086        B-66        Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun Pipe                                  36    0.375    35.25  29.5  345470.83    D        31      588      558.5    272.24  199.93  8.99  25.29  5.66 T135 M-104, B-68, B-100  Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U2 Disch Tun Unit 2 Hatch to Discharge Tunnel      36    0.375    35.25    4    46843.50    D        9      562      562      36.91    27.11  1.22  3.43  0.77 T136 M-103, B-62, B-100  Circ Water Discharge Bld to Bld Pen Embedded Pipe  Class 3  TB  U1 Disch Tun Unit 1 Hatch to Discharge Tunnel      36    0.375    35.25    4    46843.50    D        31      562      562      36.91    27.11  1.22  3.43  0.77 U2 M-1, M-2, B-39, M-                                                            Disch              Unit 2 Circ Water Discharge Pipe to T137        100          Circ Water Discharge Bld to Bld Pen  Buried Pipe  Class 3  Tun    Lake      Lake                                  168    0.75    166.5  50  13063802.54  GG        9    568.58    568.58  2179.48  7560.07  15.24 202.48 214.08 U1 M-1, M-2, B-39, M-                                                            Disch              Unit 1 Circ Water Discharge Pipe to T138        100          Circ Water Discharge Bld to Bld Pen  Buried Pipe  Class 3  Tun    Lake      Lake                                  168    0.75    166.5  50  13063802.54  GG        31    568.58    568.58  2179.48  7560.07  15.24 202.48 214.08 Page 123 of 123}}

Latest revision as of 16:12, 4 February 2020

Tsd 14-016 Rev 0, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
ML17208A116
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 02/25/2017
From: Farr H
EnergySolutions, ZionSolutions
To:
Division of Decommissioning, Uranium Recovery and Waste Programs
Shared Package
ML17208A121 List: ... further results
References
TSD 14-016, Rev 0
Download: ML17208A116 (123)


Text

ZionSolutions, LLC.

Technical Support Document TSD 14-016 Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State Revision 0 Originator: ___ _______________________ Date: __2/25/17__________

Harvey Farr Reviewer: ______________for DC per e-mail 02/23/17 Date:__ 2/25/17_________

David N. Carter Reviewer: ____________________________________ Date:__ 2/25/17________

Robert F. Yetter Approval: ____________________________________ Date: ___2/25/17________

Donald E. Williams Page 1 of 123

TSD 14-016 Revision 0 Summary of Changes in this Revision:

  • Rev. 0 -Initial issuance.

Page 2 of 123

TSD 14-016 Revision 0 TABLE OF CONTENTS

1. PURPOSE ...................................................................................................................................... 7
2. DEFINITIONS .............................................................................................................................. 7
3. DISCUSSION ................................................................................................................................ 7 3.1. General Void Space Volume and Surface Area Method.....................................7 3.2. Preliminary MARSSIM Classification .............................................................7
4. CALCULATIONS ......................................................................................................................... 8 4.1. Containment Penetrations and Embedded Piping ..............................................8 4.2. Containment Incore Area Embedded Piping ...................................................11 4.3. Main Steam and Tendon Tunnel Aerated Drain Piping ....................................12 4.4. Auxiliary Building Penetrations and Embedded Piping ...................................20 4.5. Turbine Building Penetrations and Piping ......................................................44 4.1. Circulating Water Intake Piping ....................................................................58 4.2. Circulating Water Discharge Piping ..............................................................62 4.3. Crib House Penetrations and Embedded Piping ..............................................67 4.4. Waste Water Treatment Facility Penetrations and Buried Piping ......................69 4.5. Buried Piping Inventory ...............................................................................71 4.6. Fuel Handling Building ...............................................................................71
5. CONCLUSION............................................................................................................................ 72
6. REFERENCES ............................................................................................................................ 74
7. ATTACHMENTS........................................................................................................................ 75 7.1. Attachment A - Building Penetrations South .................................................75 7.2. Attachment B - Building Penetrations North ..................................................75 7.3. Attachment C - Building Penetrations East ....................................................75 7.4. Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains ............75 7.5. Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains.............75 7.6. Attachment F - End State Penetration and Piping Inventory ............................75 7.7. Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 75 7.8. Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory ....................................................................................................75 7.9. Attachment I - Auxiliary Building Affiliated Penetrations and Piping ..............75 7.10. Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 75 7.11. Attachment K - Waste Water Treatment Facility ............................................75 7.12. Attachment L - Crib House Penetrations and Piping .......................................75 7.13. Attachment M - Fuel Handling Building Affiliated Penetrations, Piping ...........75 7.14. Attachment N - Buried Pipe Penetrations and Piping Inventory ........................75 7.15. Attachment O - Circulating Water Intake Penetrations and Piping ...................75 7.16. Attachment P - Circulating Water Discharge Piping Inventory ........................75 LIST OF TABLES Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space .............................................................................................................................................. 10 Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes ............... 10 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes ............... 11 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume ............... 12 Page 3 of 123

TSD 14-016 Revision 0 Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2......................................................... 12 Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3......................................................... 12 Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4......................................................... 13 Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5 ..................................................................... 13 Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7 ..................................................................... 13 Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe .............................................................. 13 Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump ................................................ 14 Table 12 - Main Steam Tunnel Drain M9 Center Pipe ........................................................................... 14 Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7 ...................... 14 Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths ............................................. 15 Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10 .................... 15 Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217 ................... 16 Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths ............................................. 16 Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle .................................. 16 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space .............................................................................................................................................. 19 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space ............................................................................................................................. 19 Table 21 - 24" Safety Injection Pipe Segments A36 and A51 ................................................................ 26 Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths ................................................................................................................................................... 27 Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths ................................................................................................................................................... 28 Table 24 -A40 Unit 1 4" Drain Line Segment Lengths .......................................................................... 29 Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths ..................................................... 30 Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths ................................................. 31 Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths .............................................................. 31 Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths ..................................................... 32 Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths ................................................... 33 Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2" ................................................................. 33 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths .......................................... 34 Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths ................................ 34 Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths ................. 35 Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths ..................................................... 35 Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths........................................... 36 Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths ...................................................... 36 Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths

................................................................................................................................................................ 37 Table 38 - A58 OCT-061-2" Line Segment Lengths ............................................................................. 38 Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths ........................... 39 Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3" . 41 Table 41 - Service Water Supply Header Pipe Lengths C26 & C29 ...................................................... 43 Table 42 - Summary of Auxiliary Building Affiliated Penetrations ...................................................... 43 Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall .......................... 44 Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33 .................. 48 Table 45 - Estimated Lengths of T95 and T102. ................................................................................... 52 Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes ............ 55 Page 4 of 123

TSD 14-016 Revision 0 Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping ...................................................................................................................................................... 57 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes. ................................................................................................................................................. 58 Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes .... 58 Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers ....................................................................................................................... 60 Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128 ..................... 61 Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes .................................................................................................................................................. 62 Table 53 - 48 Inch Circulating Water Standpipe Lengths ...................................................................... 64 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths .............................................. 67 Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths .............................................. 67 Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay ....................... 67 Table 57 - Summary of Crib House Penetrations at Match Line AA .................................................... 68 Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space ....................................................................................................................................................... 69 Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces ..................................... 71 Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces . 72 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes ...... 73 TABLE OF FIGURES Figure 1 - Overall Layout of Containment Penetrations .......................................................................... 8 Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4 .......................................... 9 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping .................................................. 10 Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)....................................................................... 11 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210 ....................................................... 15 Figure 6 - Tendon Access Gallery Details (B-210) ................................................................................ 17 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466 ............................................................. 18 Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23. ............................................ 20 Figure 9 - M-107 Sh2 Excerpt Top View ............................................................................................... 21 Figure 10 - Side View Unit 1 Excerpt from B118 .................................................................................. 22 Figure 11 - Side View Unit 2 Excerpt from B-120 ................................................................................ 22 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107 ......................................... 23 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106..................... 24 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions ...................................................... 25 Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2 ................... 26 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall ....................................................... 27 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2 ................................ 29 Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2 ........................................... 30 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines ...................................... 31 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout ........................................................ 32 Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply ..................................... 34 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2 ............................................................ 37 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination .......................................................... 38 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path ........................................................... 39 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout .............................................................. 40 Page 5 of 123

TSD 14-016 Revision 0 Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines ................................... 40 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106. .................. 42 Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers .............................................................................................................................................. 42 Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106 ............................................. 44 Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104 ............................... 45 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103 ............................... 46 Figure 32 - Unit 2 North Diesel Oil Penetrations ................................................................................... 47 Figure 33 - Unit 1 South Diesel Oil Penetrations ................................................................................... 47 Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers ..................... 48 Figure 35 - Turbine Building East Wall Penetrations - North ................................................................ 50 Figure 36 - T95 and T102 Buried and Embedded Sections.................................................................... 51 Figure 37 - Turbine Building East Wall Penetrations - South ................................................................ 52 Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building 53 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105 ................................................... 54 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103 .......................... 56 Figure 41 - Circ Water Intake Supply to Condensers ............................................................................. 59 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127 ..................... 61 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2 .................................... 62 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel ........................................ 63 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100 .................. 64 Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100 ........................... 65 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return ........................................................ 66 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2 ................................................................ 68 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005 .. 70 Figure 50 - Top View Approximate Penetration Locations B-1024 ...................................................... 71 Page 6 of 123

TSD 14-016 Revision 0

1. PURPOSE The purpose of this document is to provide an inventory of the embedded piping, buried piping, and penetrations that will remain in the end state structures (i.e., below 588 foot elevation) at the Zion Nuclear Power Station (ZNPS). The document provides a basis for the estimated lengths and diameters, and also estimates the surface areas and void spaces associated with them. The document also provides the current planned end state (e.g., pipe removed from penetration or pipe remains in penetration). Penetrations along with elevation and reference drawings for the Unit 1 and 2 Containments, Auxiliary Building, Spent Fuel Building, Turbine Building and Crib House, Tendon Tunnels, Main Steam Tunnels, and the Waste Water Treatment Facility WWTF are summarized in Attachments A thru E. A final list if all piping and penetrations with estimated lengths, surface areas, and void space is provided in Attachment F.
2. DEFINITIONS Embedded Pipe - A pipe that is encased in concrete and that runs vertically through a concrete wall or horizontally through a concrete floor and is contained within a given building.

Buried Pipe - A pipe that runs through soil is defined as a buried pipe.

Pipe Penetration - A pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.

3. DISCUSSION 3.1. General Void Space Volume and Surface Area Method The use of the inside versus outside diameter varies depending on whether or not the piping is embedded and cannot be removed but will left in place and surveyed. If the piping is removed the outer diameter is used unless it is through a larger sleeve, in which case the inside diameter of the sleeve is used. The equation used for the inside surface area is Equation 1.

Equation 1 - Surface Area of Opening

= 2 Where r = the pipe radius used (inner or outer as described above) or the sleeve radius used.

h = pipe length in same units as r.

The equation for the void space volume is Equation 2.

Equation 2 - Void Space Volume of Opening

=

3.2. Preliminary MARSSIM Classification A preliminary MARSSIM Classification was assigned to the piping and penetrations evaluated in this document. This classification was based upon knowledge of Pressurized Water Reactor systems and system contamination levels at Zion. Class 1 systems are those that have a high probability of a Page 7 of 123

TSD 14-016 Revision 0 Derived Concentration Guideline Level concentration being exceeded. The systems are those that contained high activity water, such as Waste Discharge lines, Spent Fuel Pool, fill drain and clean-up lines, Residual Heat Removal lines, etc. Class 2 MARSSSIM lines are those that have a 50%

probability of exceeding a DCGL. These are generally secondary systems with the potential for cross contamination from primary system to secondary system leaks, such as Component Cooling, Main Steam, Feedwater, etc. Class 3 systems have a less than 50% chance of exceeding a DCGL. These are generally secondary systems with very low probabilities of significant cross contamination due to the volumes of the systems and potential decrees of cross contamination, such as Fire Protection, Primary Water, Demineralized Water, Station Air, Instrument Air, etc.

4. CALCULATIONS 4.1. Containment Penetrations and Embedded Piping As noted in TSD 13-005 (1) and TSD 13-006 (2) the current plan is to remove all concrete inside the liners of the containment except for the incore sump area and access tunnel. This will minimize the amount of embedded piping remaining in the end state such that penetrations will make up the bulk of the surface area.

Unit 1 and Unit 2 containment penetrations are provided in drawings Unit 1 M-281, M-282 and Unit 2 M-661, M-662. As seen in Attachments A and B, the penetrations are located in three areas in the containment walls, the east and west Main Steam Tunnels and the Unit 1 north and Unit 2 south penetrations into the Auxiliary Building pipe chases as seen in Figure 1. Current plans are to remove piping from these penetrations leaving only the sleeves.

Figure 1 - Overall Layout of Containment Penetrations The penetrations and through wall piping are identical in both Unit 1 and Unit 2. The penetrations and the length and diameters of the penetrations with and without the piping (i.e., Open Sleeve) are provided in Attachment F and G.

There are also penetrations where the pipe will remain in the penetration (Pipe in Sleeve). As seen in Figure 1, each containment also has a penetration for the fuel transfer tube connecting the lower Page 8 of 123

TSD 14-016 Revision 0 cavity to the Fuel Handling Building Transfer Canal. Current plans are to leave the piping in place for these penetrations. The ends in the Containment up ender pit have blank flanges welded on as part of the cavity isolation preparations for internal segmentation. Since the end state requires all metals other than those embedded in concrete to me removed (3), it is anticipated that the pipes will be cut flush with the walls and open in the end state.

The length of the transfer tube piping in each unit is shown as 8 2.5 (e.g., 98.5 inches) in drawing B-213 Detail 4. With 24 inch OD and a 0.688 inch wall thickness the pipe ID is 22.624 inches. The void space volume is 39,597 cubic inches or 22.92 cubic feet (0.65 m3). The surface area is 48.62 ft2 or 4.52 m2.

Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4 As seen in Figure 3, there are also three Recirculating Sump Suction lines and two Cavity Flood Sump Suction lines that connect to the Auxiliary Building. The pipes are planned to remain in their sleeves. All five pipes are 20 inch pipes with 24 inch sleeves embedded in the concrete below the liner at the 561.25 foot elevation. One Recirculation Sump line is a spare that is capped at the Auxiliary Building penetration. The estimated lengths are approximately 50 feet as seen in Figure 3. The wall thickness of the 20 inch pipe is 0.594 inches making the inside diameter 18.812 inches. Although each pipe varies slightly in length the interior surface area is approximately 252 ft2 (23.41 m2) and 98.7 ft3 (2.80 m3).

Page 9 of 123

TSD 14-016 Revision 0 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping Each Unit 1 Cavity Flood Sump and Recirculation Sump pipes estimated length, surface area, and void space volume is provided in Table 1. The corresponding Unit 2 penetrations in Attachment F are P323, P324, P235, P236, and P237. The horizontal runs under the Containment 565 liner floor level are at the 5613 elevation making the top of the 24 inch diameter pipes at the 5623 elevation which is 29 below the end state liner floor level.

Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space Void Pipe Interior Space Void OD Wall Pipe ID Length Surface Volume Int SA Space Pen No. Description inches Thkns inches Feet Area ft2 ft3 m2 m3 P123 Recirculating Sump Suction 20 0.594 18.812 52.00 256.10 100.37 23.79 2.84 P124 Recirculating Sump Suction 20 0.594 18.812 52.83 260.20 101.98 24.17 2.89 P035 Recirculating Sump Suction 20 0.594 18.812 51.17 251.99 98.76 23.41 2.80 P036 Cavity Flood Sump Suction 20 0.594 18.812 50.75 249.94 97.96 23.22 2.77 P037 Cavity Flood Sump Suction 20 0.594 18.812 50.83 250.35 98.12 23.26 2.78 All of the other penetrations below the 588 elevation are assumed to have piping cut on either side of the penetration such that the length corresponds to the wall thickness and void space volume and interior surface areas correspond to the diameter as listed in Attachment F. The total estimated pipe lengths, surface areas and void space volumes in meters are provide in Table 2. The inventory associated with the Unit 1 and Unit 2 Containments are provided in Attachment G.

Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes Sum of Sum of Unit 1 Category, End Length Sum of Void Space State meters Int SA m2 m3 Bld to Bld Pen 169.20 242.36 32.48 Open Sleeve 88.19 119.99 17.75 Pipe in Sleeve 81.01 122.37 14.73 Page 10 of 123

TSD 14-016 Revision 0 Grand Total 169.20 242.36 32.48 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes Sum of Sum of Unit 2 Category, Length Sum of Int Void Space End State meters SA m2 m3 Bld to Bld Pen 169.20 242.36 32.48 Open Sleeve 88.19 119.99 17.75 Pipe in Sleeve 81.01 122.37 14.73 Grand Total 169.20 242.36 32.48 4.2. Containment Incore Area Embedded Piping There is also a 1 1/2 pipe embedded in the concrete of the Incore Access Tunnel P125 for Unit 1 and P325 for Unit 2 on Attachment F. The incore area extends below the containment slab and consists of a cylindrical area directly under the reactor vessel biological shield and a sloped tunnel. The incore area walls are 1 foot 11.5 inches thick (23.5 inches) with a 2 foot 6 inches under vessel area floor. There is also an access tunnel with 15 inch thick walls, floor and roof. The sump is shown on drawing B-234 as being 2x 2x 2 at about 1 from the from the bend line. The pipe enters the wall about a floor above the sump making the opposite of the triangle 17+9-36 or 226 as seen in Figure 4. The base is 433 - 309 or 126 making the hypotenuse length 25.74 assuming the pipe enters the wall for about a foot before sloping up results in an estimated length of 26.74.

Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)

The estimated length, surface area, and void space volume in meters is provided in Table 4. The inventory of the incore pies is provided at the end of Attachment G.

Page 11 of 123

TSD 14-016 Revision 0 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume Sum of Length Sum of Int SA Sum of Void Space Row Labels meters m2 m3 Bld Pen 8.15 1.05 0.01 Embedded Pipe 8.15 1.05 0.01 Grand Total 8.15 1.05 0.01 4.3. Main Steam and Tendon Tunnel Aerated Drain Piping The tendon access tunnel galleries also contains a sump that has trace levels of contamination in sump water and sludge samples as well as trace levels of removable contamination. The Main Steam Tunnel floor drains also drain to this sump. There are 4 Aerated drains embedded in the tendon gallery access tunnel and Main Steam Tunnel floors. The Tendon Tunnel runs under the periphery of the Containment as shown in Figure 5 and has a floor elevation of 565-9-76 or 5486.As seen in Attachment D and Attachment E excerpted from drawings B-466, B-477, B-484, and B-487 the Main Steam Tunnel and Tendon Tunnel aerated drains are connected and drain to a common sump in the tendon tunnel. The Unit 1 drawings are shown on B-466 and B-467. The Unit 2 pipes are shown on B-481 and B-487. All of the pipes have a 4.5 inch outer diameter and 4.026 inch inner diameter. The penetrations are comprised of floor drains and clean out ports in the Mains Steam Tunnel that connect to a common header pipe. Attachment D shows M1 is a drain at 5696 1/2 to a bend beneath the floor. As seen on B-484 M1 drops to the 569 which is 0.54 feet. The pipe then makes a 45 degree run to the main drain line. As seen on B-466 the clean out port is 84 -2 thick wall or 64 from the wall. The 45 degree section is thus the hypotenuse of a 64 45 degree triangle or 8.96 feet. At Cleanout port M2 the pipe makes a 45 degree bend from the 569 to the 5687 or a 5 x 5 45 degree triangle which is 0.59 feet. The length of the run at 569 elevation between the 45 degree section is 48-64-5-6 from the wall or 353. As seen in Table 5. The Unit 2 drain M201 has slightly different lengths due to different elevations.

Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2 Pipe Section M1 M201 Vertical 0.54 0.69 45 Degree Bend 8.96 8.96 45 Degree at Cleanout 0.59 0.62 Section between 45s 35.25 35.23 Total Length 45.34 45.49 Penetration M2 is a 4 cleanout port that has a vertical section from the 56911 floor of the tunnel to the 5673 or 28 where it runs under the floor in a concrete encasement as shown on drawing B-466. It then run 38 from M2 to M3 resulting in a distance of 408 as seen in Table 6. The Unit 2 drain M202 has slightly different lengths due to different elevations.

Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3 Pipe Section M2 M202 Vertical 2.67 1.50 Section to M3, M203 38.00 38.00 Total Length 40.67 39.50 The M3 vertical is the same as M1. There is a 45 degree bend from 56811 to 5673 or 18 at M3. This creates a 2.36 length. The length from the drain to the 45 degree angle is 6-18 or 44. The distance from Page 12 of 123

TSD 14-016 Revision 0 M3 to M4 at the 5673 elevation is 75-19+30 or 86 resulting in a total length of 93.23 feet as seen in Table 7. The Unit 2 drain M203 has slightly different lengths due to different elevations.

Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4 Pipe Section M3 M203 Vertical 0.54 0.67 Drain to Section to 45 4.33 5.54 45 Degree Bend 2.36 0.65 Section to M4 86 86 Total Length 93.23 92.86 The vertical at M4 is the same as M1 and M3 at 6 1/2 or 0.54 feet. There is a 45 degree bend from the 56810 to the 5673 elevation or 17. The hypotenuse of the 17 45 degree triangle is 2.24 feet. The distance to the 45 degree bend is 6-17 or 45 which is 4.42 feet. There is a 45 degree bend from 5673 to 5662 or 11 near cleanout M5. There is a 45 degree bend at M5 from 5673 to the 5662 elevation or 11 which equals a 1.53 foot hypotenuse. The distance of the run at the 5673 from M4 to M5 is 92-30+26-11-10 for 76.92 resulting in 84.11 feet overall length from M4 to M5 as seen in Table 8. The Unit 2 drain M204 has slightly different lengths due to different elevations.

Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5 Pipe Section M4 M204 Vertical 0.54 0.71 Section drain to 45 4.42 5.54 45 Degree Bend 2.24 0.65 Section to 45 degree at M5 76.92 75.96 45 bend at M5 1.53 2.89 Total Length 84.11 82.86 M5 is a clean out at G34 that has a vertical section from 56911 to 5662 or 39. The length of the 5662 pipe from M5 to M7 can be interpolated at 306 feet based on the 24 dimension between columns 33 and 34 on B-466. This provides and overall length from M5 to M7 of 343 feet as seen in Table 9. The Unit 2 drain M205 has slightly different lengths due to different elevations.

Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7 Pipe Section M5 M205 Vertical 3.75 3.54 Section to M7 30.50 30.50 Total Length 34.25 34.04 M6 has a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5662 elevation for a 210 base resulting in a 4.01 hypotenuse. The distance from the drain to the wall is 10 feet leaving a 72 foot section from the drain to the 45 degree bend. This results in a 11.72 foot overall length as seen in Table 10. The Unit 2 drain M206 has slightly different lengths due to different elevations.

Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe Pipe Section M6 M206 Vertical 0.54 0.67 Section drain to 45 7.17 6.80 Page 13 of 123

TSD 14-016 Revision 0 45 Degree Bend 4.01 4.48 Total Length 11.72 11.95 M7 is a clean out with a vertical from the 56911 1/2 floor to 5661 or 310 1/2. The clean out connects to a main pipe segment that goes to the Tendon Tunnel Sump. Drawing B-481 is more legible showing the cleanout to the bend is 26-13+58 or 188 for Unit 2. B-481 shows the length of the bend to the vertical to be 22 7 1/2 or 22.625 feet. The vertical drop from 5658 to the Tendon Tunnel Sump at 5436 is 222 equaling a total length from M-7 to the sumo of 674 as seen in Table 11. The Unit 2 drain M207 has slightly different lengths due to different elevations.

Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump Pipe Section M7 to M8 M207 to M208 Vertical 3.88 3.85 Section to bend 18.67 18.67 Bend to Vertical at M8 22.625 22.625 Vertical M8 to Sump 22.17 21.67 Total Length 67.33 66.81 M9 is similar to the other drains with a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5687 elevation for 5 base resulting in a hypotenuse or a 5 x 5 45 degree triangle which is 0.59 feet. As seen on B-482 for the Unit 2 equivalent section the distance from M9 to the main pipe from M-10 to M-7 is 26 feet from match line J to L minus 49 from L to the wall interior and minus 13 from J to cleanout M-10. Thus, the length from the drain to the 45 degree bend is 26-49-13-5 or 710. As seen in Table 12, the total length is 8.96 feet. The Unit 2 drain M209 has slightly different lengths due to different elevations. The Unit 2 drain M209 has slightly different lengths due to different elevations.

Table 12 - Main Steam Tunnel Drain M9 Center Pipe Pipe Section M9 M209 Vertical 0.54 0.67 Section drain to 45 7.83 8.18 45 Degree Bend 0.59 0.10 Total Length 8.96 8.95 Cleanout port at M10 has a vertical from 56911 1/2 to 5689 1/2 or 1.17 feet. The equivalent section on B-481 shows a length of 193+226 or 419 from M10 to M7. The line drops 2.5 inches over this length but this does not add significantly to the length. The pipe the has a vertical drop from 5687 to 5661 or 26 to join the line from M7 to M8. This results in a total length from M10 to M7 of 45.42 feet. The Unit 2 drain M210 has slightly different lengths due to different elevations. The Unit 2 drain M210 has slightly different lengths due to different elevations.

Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7 Pipe Section M10 to M7 M210 to M207 Vertical 1.17 1.16 Section to bend 41.75 41.81 Bend to Vertical at M7 to 566'1" 2.5 0.5 Total Length 45.42 43.47 M11 is similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M11 to center pipe can be interpolated at 165 feet based on the 24 dimension between columns 33 and 34 Page 14 of 123

TSD 14-016 Revision 0 on B-466. The length from the drain to the pipe is 6.96 feet as seen in Table 14. The Unit 2 drain M211 has slightly different lengths due to different elevations.

Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths Pipe Section M11 M211 Vertical 0.54 0.60 Section drain to main pipe 16.42 16.42 Total Length 16.96 17.02 M12 is also a drain similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M12 to center pipe is 21-14-165 or 33. The length to M10 from M12 is shown on the Unit 2 equivalent section of B-481 at 14+13 or 27. The total length is 20.79 feet as seen in Table 15. The Unit 2 drain M211 has slightly different lengths due to different elevations.

Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10 Pipe Section M12 M12 Vertical 0.54 0.60 Section drain to main pipe 3.25 3.25 M12 to M10 27.00 27.00 Total Length 30.79 30.85 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210 As seen in Figure 5, the Tendon Tunnel floor is at 5486 elevation. The walls and floors are 2 thick making the interior floor width 46. There are drains from the Tendon Tunnel Buttress Pits that connect drain header in the Tendon Tunnel. The Buttress Pits are divided in to two sections by a wall in the center. A drainage system consisting of a through wall drain that allows accumulated water in one chamber to drain into the adjacent chamber and then through a floor drain down to the tendon tunnel floor drain header connected to the tendon tunnel east sump. As seen in Figure 7, there are 5 Unit 1 drains M13 thru M17 and 5 Unit 2 M213 thru M217 from the Tendon Buttress Pits at the 564 11 1/2 that drop 13 1/2 to the 5638 where they run horizontally about 36 into the center of the 2 thick wall. The lines then run vertically to the 5479 which 9 below the Tendon Tunnel Floor slab. They then run horizontally on a 45 degree angle to join the drain Page 15 of 123

TSD 14-016 Revision 0 pipes at the center of the tunnel. The tunnel is 46 wide making it 23 from the wall interior to the pipe.

The wall is 2 feet thick making the length to wall 1 foot making the base of the 45 degree pipe 33 which results in a total length of 4.6. This is a total length of 30.3 feet for each of the 5 pipes for a total of 151.52 feet per Unit as seen in Table 16.

Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217 Pipe Section M13 - M17 M213 - M217 Vertical to Horizontal 1.29 1.29 Horizontal into Tendon Tunnel Wall 3.5 3.5 Vertical to Tunnel 20.92 20.92 Horizontal to Center Pipe 4.60 4.60 Total Individual Length 30.30 30.30 Total M13 - M17 Length 151.52 151.52 As seen in Figure 7, the Tendon Tunnel drains are embedded approximately 7 inches in the floor at the 54611 elevation. The drains M18 through M23 and M18 through M223 have a vertical section from 548 6 1/2to 54711 or 7 1/2. The total length of these vertical section in Unit 1 and Unit 2 is 39.

Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths Unit 1 Unit 2 Pen Length ft Pen Length ft M018 0.625 M218 0.625 M019 0.625 M219 0.625 M020 0.625 M220 0.625 M021 0.625 M221 0.625 M022 0.625 M222 0.625 M023 0.625 M223 0.625 Total 3.75 3.75 Drawing B-210 shows that the tunnels are 46 wide with 2 thick walls. B-481 shows that M18 is at the 368 degree mark and M23 is at the 68 degree mark. B-481 shows M223 is at the 68 degree mark and M218 is at 368 degrees. As seen in Table 18, the pipe is 83% of a circle.

Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle Unit 1 Unit 2 Start End Total Start End Total Degree Degree Degrees Degree Degree Degrees 68 0 68 68 0 68 360 368 -8 360 368 -8 Total 60 60 Pipe Percent Circle 83% 83%

As seen in Figure 6, it is 666 to the interior wall, with the pipe in the center that would add 23 making the pipe radius 689. This is also shown on drawing B-466 and B-481 as seen in Figure 7.

Page 16 of 123

TSD 14-016 Revision 0 Figure 6 - Tendon Access Gallery Details (B-210)

Page 17 of 123

TSD 14-016 Revision 0 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466 M24 and M244 are the circular portion of the embedded pipe. The 689 radius multiplied by 2 Pi and 0.83 for the percentage of the circle results in a 359.97 length. The pipe from M25 to the sump is 23 to the wall then 76 to the sump or 99.

A summary of the Unit 1 and Unit 2 Main Steam drains estimated lengths, surface areas and void space volumes in meters are provide in Table 19. Table 20 has the summary for the Buttress Pit and Tendon Tunnel drains. The list of penetrations and pipes is provided in Attachment H.

Page 18 of 123

TSD 14-016 Revision 0 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Sum of Length Sum of Int SA Sum of Void Space Category and End State meters m2 m3 U1 Aerated Drain 145.93 46.88 1.20 U1 Bld Pen 145.93 46.88 1.20 Embedded Pipe 145.93 46.88 1.20 U2 Aerated Drain 144.41 46.39 1.19 U2 Bld Pen 144.41 46.39 1.19 Embedded Pipe 144.41 46.39 1.19 Grand Total 290.34 93.28 2.38 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Sum of Length Sum of Int SA Sum of Void Space Category and End State meters m2 m3 U1 Bld Pen 160.02 51.41 1.31 Embedded Pipe 160.02 51.41 1.31 U2 Bld Pen 160.02 51.41 1.31 Embedded Pipe 160.02 51.41 1.31 Grand Total 320.04 102.82 2.63 Page 19 of 123

TSD 14-016 Revision 0 4.4. Auxiliary Building Penetrations and Embedded Piping Auxiliary Building penetrations are provided in drawings M-281, M-282 for Unit 1 and M-661, M-662 for Unit 2. The penetrations to the Spent Fuel Building are located at R17 and R23 as seen in Attachments A and B. Drawing M-107 Sheet 1 Section A-A and B-B show the end view of the penetrations in the Auxiliary Building as seen in Figure 8. Note that Unit 1 penetration A29 is unlabeled on M-107 Sheet 1. There is also an unlabeled penetration on M-107 Sheet 2 next to the A43 penetration of OFP-016-4 on M-107 Sheet 2 at Column 22 between match line X and U. However, this line is labeled on the drawing as 1SF-017-2 next to the OFP-016-4 at column 24 match line S.

Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23.

Page 20 of 123

TSD 14-016 Revision 0 M-107 Sheet 2 shows most of the pipes paralleling the Spent Fuel Building foundations then rising vertically to above the 583 elevation after passing under the Fuel Transfer Canal. The exceptions being those pipes with boxes around them in Figure 8. These are a 2 inch diameter oil line A42 ODO-100-2 that remains near the 573 elevation and a 4 inch vent line A40 1AD-046-4 that only rises to the 579 elevation. These lines routes are traced in red in Figure 9. The Unit 1 and 2 24 diameter Safety Injection lines A36 and A51 also do not rise above the 573 elevation.

Figure 9 - M-107 Sh2 Excerpt Top View Enlarged Plan A and Plan B of M-107 Sheet 1 show the top view and piping lengths as the parallel the Containments and pass under the Spent Fuel Transfer Canal as seen in Figure 12. B-118 shows the side view of the Unit 1 piping relative to the foundation and clearly indicates as seen in the red circled notations noted in excerpt provided as Figure 10. The Unit 2 side view from B-120 has similar notations indicating the piping is encased in concrete as seen in Figure 11.

Page 21 of 123

TSD 14-016 Revision 0 Figure 10 - Side View Unit 1 Excerpt from B118 Figure 11 - Side View Unit 2 Excerpt from B-120 Page 22 of 123

TSD 14-016 Revision 0 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107 Drawing M-106 Sections K-K and K1-K1 show the side view of the piping passing through the walls of the Auxiliary Building, Under the Spent Fuel Transfer Canal and out through the Spent Fuel Building Walls as seen in Figure 13.

Page 23 of 123

TSD 14-016 Revision 0 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106 As seen in Figure 8, Figure 9, Figure 10, and Figure 11 both Unit 1 and Unit 2 penetrations to the Spent Fuel Building have a 24 inch Safety Injection line 1SI-012-24 and 2SI-012-24 A36 and A51 that run from match line R to match line X. As seen in Figure 9 the lines were installed for a future Safety Injection tank that was never installed. Consequently, the lines are capped on both ends and were never used.

Page 24 of 123

TSD 14-016 Revision 0 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions As seen in Figure 14, the distance to the bend is 6 for the cap plus 39 and 159 as seen on M-107 Sheet 2 which is 20 feet. M-105 SH2 also shows the 45 degree bends is 310 the hypotenuse of which is 5.421 feet.

As seen in Figure 13, the centerline elevation at R is 568 plus 2 or 570. This makes the remaining distance to match line S 25-159-310 or 55. There is also an elevation change at the bend from 570 inches to Page 25 of 123

TSD 14-016 Revision 0 573 feet increasing the length of the bend by the square root of 5.421^2 + 3^2 to a length of 6.2 feet. The distance from match line S to the end cap past X is 25+126 plus 1 to the end cap or 386 for a total length of 70.11 feet.

Table 21 - 24" Safety Injection Pipe Segments A36 and A51 Section Length feet End Cap at R 0.5 Length to elbow 19.5 Bend 6.20 Remaining to S 5.42 Remaining to End Cap 38.50 Total 70.11 As seen on Figure 8, each unit also has two 10 diameter component cooling lines A49 1CC-078-10, A50 1CC-080-10, A59 2CC-078-10, A60 2CC-080-10. They are at the 5707 at match line R. As seen in Figure 13, the pipes run horizontally from R to where they make a vertical rise to the 584 elevation. The length is 1+29+133+9+9 or 186. The pipes then rise vertically from 5707 to the 584 elevation or 135. For Unit 1 the pipes then run parallel to the SFB past match line X where they pass through the wall.

Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2 The distance from vertical to match line S is25-149 or 103, the then proceeds 25 to X. Past X they turn North through the wall at A49 64 for 417 length and A50 710 for a 431 length.

Page 26 of 123

TSD 14-016 Revision 0 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall As seen in Figure 8, A49 is 39+110 from Column 23 or 57 and A50 is an additional 14 from column 23 or 611. It is 26 from column 23 to column 21 and 176 to column 20. The Unit 1 penetrations through the 592 floor are 16 beyond that making the total from column 23 45 feet. A 4 foot long vertical section will remain from the 584 to the 588 elevation. The calculated pipe segment lengths and the overall lengths are summarized in Table 22.

Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths A49 Unit 1 Length A50 Unit 1 Section feet Length feet Length R to Vertical to 584' 18.5 18.5 Length of Vertical 570'7" to 584' 13.42 13.42 Length from Vertical to SFB Wall Penetrations 41.58 43.08 Distance North to Col 23 5.58 6.92 Distance Col 23 to Vertical 45.00 45.00 Vertical Toward Slab 4 4 Total 128.08 130.92 Page 27 of 123

TSD 14-016 Revision 0 The Unit 2 10 Component Cooling lines A59 2CC-078-10 and A60 2CC-080-10 paths are also shown in Figure 15. The distance to the 584 vertical and to vertical lengths are the same as Unit 1 186 and 135.

The distance to S is 25-14-9 or 113. The distance to from X to the bend of A59 2CC-078-10 is noted as 3+39 or 69. There is an additional 6 feet from the notation of 8 pieces at 8 inches. The distance from S to the bend is the 25 from S to X minus 129 or 123. The total length of A59 2CC-078-10 from the vertical to 584 elevation is 236. The length of A60 2CC-080-10 is 26 closer to S or 21. For the southward segment between S & X as seen in Figure 15, the distance from column 17 is the distance from column 19 to 17 26-149 or 113 inches. As seen in Figure 8, the distance from column 17 to A59 2CC-078-10 is 39+110 or 57. A 60 2CC-080-10 is an additional 14 further or 611. The length of A59 to the bend north is 113+57 or 1610. The length of A60 is 113+611 or 182. The segment west past match line X for A59 2CC-078-10 is 26+3+39 to X with an additional 64 past X or 157. The distance west for A60 is 3+39+64+16 or 147. The distance south again to the vertical from 584 to the floor penetrations on 593 is 149+2 for both pipes as seen on Figure 15. A 4 long part of the vertical from 584 to 588 elevation will also remain. The lengths of each segment and totals lengths are provided in Table 23.

Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths A59 Unit 1 Length A60 Unit 1 Section feet Length feet Length R to Vertical to 584' 18.5 18.5 Length of Vertical 570'7" to 584' 13.42 13.42 Vertical to Bend South 23.5 21 South to Bend West 16.83 18.17 West to Bend South Past X 15.58 14.58 South to Vertical to Pens 16.75 16.75 Vertical to 588 4.00 4.00 Total 108.58 106.42 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 4 inch drain line A40 1AD-046-4 at the 5694 elevation at match line R. As seen in Figure 14 the 4 line A40 1AD-046-4 runs horizontally from R to where it makes a vertical rise to the 5799 elevation. The length to the vertical bend is 1+29+133+9+9 or 186. The pipe then rises vertically from 5694 to the 5799 elevation or 105.

The 4 drain pipe then runs west parallel to the SFB past match line X sloping up to the 5808 elevation before going through the wall of the Spent Fuel Building. It is 103 from the vertical to match line S. It is 25 from S to X and the line makes its bend 3 feet past X for a total length of 383. It rises 11 providing a hypotenuse of 38.26 feet.

Page 28 of 123

TSD 14-016 Revision 0 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2 As seen in Figure 8, A40 is 39+14+1+16+9+9 or 91 from Column 23. It is 26 feet to column 21 and the pipe extends another 176 - 123 or 53 for a total length of 91 + 26+ 53 or 404. The pipe also rises a foot to the 5818 making the hypotenuse length 40.35 feet. The pipe then runs west again 11 feet and rises from 5818 to 582 but the slight change does not affect the length. The pipes then rise vertically from the 582 to the 588 elevation for a 6 foot vertical segment. The segment lengths and total lengths are provided in Table 24.

Table 24 -A40 Unit 1 4" Drain Line Segment Lengths A40 Unit 1 Length Section feet Length R to Vertical to 584' 18.5 Length of Vertical 569'9" to 579'9" 10.42 Length from Vertical to SFB Wall Penetrations 38.26 Distance North to Bend West 40.35 West to Vertical through Slab 11.00 Vertical to 588' at Floor Pen 6.00 Page 29 of 123

TSD 14-016 Revision 0 Total 124.52 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 2 inch oil line A42 ODO-100-2 that remains near the 573 elevation. The 2 inch oil line is at the 5694 at match line R. As seen in Figure 13 the pipe runs horizontally from R to where it makes a vertical rise to the 5722 elevation near the 45 degree bend in the SI pipe. Figure 13 and Figure 17 show the length is 1+39+159 or 206. Along this length, the pipe slopes upward from 5684 to 5688 but this does not significantly affect the length. The vertical rise is 5722-5698 or 26. From the 26 vertical it continues west the length to match line S is25-159 to X 25 to 49-3 or 19 past X for a total length of 36 feet. As seen on Figure 17 the pipe slopes upward from 5722 to 5736 over the length past X for a 14 rise which results in a length of 36.02 feet. The line then continues south toward the tank and slopes vertically from the 5736 elevation to the 576 elevation or 26 over the length which is 151-65 or 88 to the center of the tank. With the 26 rise this is 9.02 to the center of the tank. Assuming the pipe from the wall to the tank is removed during the excavation and removal of the tank this is a length of about 46 feet.

Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths A42 Unit 2 Length Section feet Length R to 4" Vertical to 569'8" 20.50 Vertical to 572'2" 2.50 Vert to 572'2" West to Vertical Past X 36.02 Vertical to 576' 4.52 Total 63.55 Each Unit has three 1.5 Tell Tale drain lines as seen Figure 8. The penetration and line identifications are A38 1AD-148-1 1/2, A39 1AD-147-1 1/2, A37 1AD-149-1 1/2 for Unit 1 and A53 2AD-148-1 1/2, A54 2AD-147-1 1/2, A52 2AD-149-1 1/2. As seen in Figure 8, these lines are at the 571 elevation at match line R. As seen on M-107 Sheet 2 and the excerpt provided as Figure 18, one of the drain lines in each unit goes vertically into the transfer canal wall between the pool and the canal. The other two go vertically toward the 584 elevation penetrations at the 186 bend.

Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2 M-106 Section K-K, K1-K1 shows the two Tell Tale drain lines extending vertically without bending to process west with the other pipes.

Page 30 of 123

TSD 14-016 Revision 0 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines As seen on the Unit 2 side of M-107 SH2, the first drain A54 2AD-147-1 1/2, and A39 1AD-147-1 1/2 elbow into the Fuel Transfer canal concrete is 39+53 to the wall or 9 feet. The 1 foot dimension from the drawing transposed on the wall shows the drain line bends south it at 10 feet. The distance south is 29. The vertical section is assumed to be the 5 feet minimum distance to the bottom of the transfer canal at 576. The line segment lengths are summarized in Table 26.

Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths A39, A54 AD-147-1 Section 1/2 feet Length to Bend South 10 Length South to Vertical 2.75 Vertical to 576' 5 Total 17.75 The other four Tell Tale lines are shown in Figure 19. The distance to the vertical bend is 1+29+133+9 or 179. M-106 Section K-K shows the lines continuing vertically past the 584 elevation for a minimum length of 13. The lengths beyond that are undetermined. The lengths for the segments identified are summarized in Table 27.

Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths A38, A53 AD-148-1 A37, A52 AD-Section 1/2 feet 149-1 1/2 feet Length to Bend South 17.75 17.75 Vertical to 584' 13 13 Total 30.75 30.75 Each Unit has 1 1/2 station air lines as well A41 1SA-014-1 1/2 and A66 2SA-012-1 1/2. As seen on Figure 8 they are at the 5694 elevation. Their layout is highlighted on the M-107 SH2 overhead vie in Page 31 of 123

TSD 14-016 Revision 0 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout The Unit 1 line 1SA-014-1 1/2 goes vertical to vertical bend that leads to the 583 elevation. The length to the vertical segment is 1+29+14+9 or 186. The vertical segment is from the 5694 to the 583 or 138. The distance of the segment at 583 elevation to S is 103 and 25 to X and 3+16+45+4(9) or 1111 for a total length of 472. The line travels north to the penetration with a length of 39+14+1+16+9 or 84 to Column 23 as seen in Figure 8. The penetration is 16 past column 23 for a total length of 910.

Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths A41 1SA-014-1 1/2 Section Length Feet Length to Bend South 18.5 Vertical to 583' 13.67 West to SFB 47.17 North to Pen 9.83 Vertical to 588 5 Total 94.17 Page 32 of 123

TSD 14-016 Revision 0 The Unit 1 Service Water line is a 2-inch diameter line and with a layout parallel to the Unit 1 Station Airline 1SA-012-1 1/2 in Table 28. The Unit 1 Station Air line A44 1SA-014-1 1/2 is shown on Figure 20. The Service Water line travels the same 186 distance to the vertical. The exceptions are that the elevation at R is 5707 and the vertical rise is also to the 584 elevation making that segment 135. The length to the bend into the building is 18 shorter than the station air line at 458 versus 472. The distance north to the penetration in the floor is the slightly greater because the penetration is further from column 23 at 39+110+14+11+9+9 or 9/6 to Column 23 versus 84 for the Station Air. The penetration is 16 past column 23 for a total length of 11. same but the remaining height of the vertical segment is 4 feet rather than 5 feet since the elevation is 584 versus 583.

Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths A44 1SW-181-2" Section Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 45.67 North to Pen 11.00 Vertical to 588 4 Total 92.58 The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 runs parallel to and between the Station Air A41 1SA-014-1 1/2 and the A44 Service Water line A44 1SW-181-2. The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 is shown on Figure 20. The Instrument Air line travels the same 186 distance to the vertical. The elevation at R is 5707 the same as the Service Water and the vertical rise is to the 584 elevation making that segment 135 as well. The length to the bend into the building is 9 longer than the service water line at 465 versus 458. The distance north to the penetration in the floor is the 8 further as seen in Figure 8 making the length 118. The remaining height of the vertical segment is the same at 4 feet since the 584 elevation is the same. The pipe section lengths are summarized in Table 30.

Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2" A46 OIA-004-1 1/2" Section Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 46.42 North to Col 23 11.67 Vertical to 588 4 Total 94.00 The Unit 1 A43 Fire Protection line OFP-016-4" penetration is next to and parallels the Service Water line A44 as seen Figure 8 and Figure 20. The distance to the bend vertically is 186 inches. The elevation is also 5707 at R and 584 at the vertical resulting in the same 135 vertical length. The segment west from the vertical to 584 is 9 shorter than the Service Water pipe or 4411. As seen in Figure 8 the distance from column 23 to the penetration is 9 less than the service water making the overall length north to the penetration 103 rather than 11. The remaining vertical to the penetration is also 4 feet. The pipe segment lengths are summarized in Table 31.

Page 33 of 123

TSD 14-016 Revision 0 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths A43 OFP-016-4" Section Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 44.92 North to Pen 10.25 Vertical to 588 4 Total 91.08 As seen in Figure 17, there is an unlabeled pentation next to the Fire Protection penetration on M-107 Sheet

2. As explained in the text above Figure 8, the line is identified at Column 24 match line S as 1SF-017-2 and labeled as Demin Water indicating it was a clean water supply to the spent fuel pool. As seen Figure 21 line changes designation from 1DW012-2 to 1SF17-2 at valve 1SF0004 on drawing M-63. The M-69 shows the DW system and the start of that line and references the M-63 drawing for continuation. The M-63 drawing references the M-69 drawing and shows the SF system along with the 1SF0004 valve and the beginning of the 1SF017-2 line.

Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply The label on M-107 SH 1 indicates the lines is at the 5834 1/2 elevation. The penetration elevation at R is 5707 resulting in a vertical of 129 1/2. The length to the vertical is the same at 186. The length west from the vertical to bend north is 9 shorter to the floor penetration than the Fire Protection line at 442. The penetration at R is 9 closer to column 23 than the Fire Protection line resulting in the north segment to the floor penetration being 96. The vertical segment toward the floor penetration is longer going from 583 4 1/2to the 588 or 4 7 1/2. The pipe segment lengths are summarized in Table 32.

Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths A29 1SF-017-2" Section Length Feet Length to Bend South 18.5 Vertical to 584' 12.79 West to SFB 44.17 North to Pen 9.50 Page 34 of 123

TSD 14-016 Revision 0 Vertical to 588 4.625 Total 89.58 Several lines have penetration through the Fuel Handling Building floor east of 1SF-017-2 as seen on M-106 Sheet 2 and Figure 20. These lines are A48 1SF-008-2, A47 1SF-022-3, and A40 1AD-146-4. M-63 shows A48 1SF-008-2to be a Refueling Water Storage Tank line and A47 1SF-022-3 to be a Fuel Pool Demineralizer line indicating they are Class 1 lines. It is 186 to the vertical for both A48 1SF-008-2and A47 1SF-022-3. Both lines are at the 5694 elevation at match line R making the vertical length to 583 138 long. Both lines the travel west parallel to the Fuel Handling Building slab. The distance to match line S is again 25-149 or 103. It is 25 to X with an additional 39 for 1SF-022-3 and 46 for 1SF-008-2 past X to the bend north. The total length of the west segments from the vertical to the bend is 39 for 1SF-022-3 and 399 for 1SF-008-2. The distance of the penetrations at R from column 23 is shown in Figure 8 for 1SF-022-3 it is 39+14+1 or 61. 1SF-008-2 is 16 further south or 77. M-107 SH 2 shows the distance from column 23 south to floor penetrations in 16 for both pipes leading to lengths of 91 for 1SF-022-3 and 83 for 1SF-008-2 to the vertical segment through the slab. Each pipes vertical segment is from 583 to 588 or 5 feet. The line segment lengths are summarized in Table 33.

Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths A48 1SF-008-2 A47 1SF-022-3 Section Length Feet Length Feet Length to Bend South 18.5 18.5 Vertical to 583' 13.67 13.67 West to SFB 39.75 39.00 North to Pen 9.08 8.25 Vertical to 588 5 5 Total 86.00 84.42 The Unit 2 Station Air line A66 2SA-012-1 1/2 is shown on Figure 20. It travels the same 186 distance to the vertical and has the same vertical length of 138 to the 583 elevation. Like the other lines, it bends south between S and X. The distance from vertical to match line S is25-149 or 103. The distance to from X to the bend is noted as 3+39 or 69 with another 9 to the line for 76 which give a length from S to the bend of 25-76 or 176. The total length to the bend is 103+176 or 279. As seen on Figure 8 A66 is 39+310+9+9+9 from Column 17 or 910. It is 149 to the pipe from Column 19 with a 26 distance from columns 19 to 17 this is 113 this plus the 910 to column 17 is 211. From there it turns west again and parallels the foundation which extends to just past match line U. Piping past the foundation is assumed to be buried pipe that will be removed. It is 149 to X then 25 to U then 39 to the end of the foundation for a total length of .436 The remaining line past the foundation will be removed. The Unit 2 Station Air segment lengths are summarized in Table 34.

Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths A66 2SA-012-1 1/2 Section Length Feet Length to Vertical West 18.5 Vertical to 583' 13.67 Length West to Bend South 27.75 South from Bend Past S to Bend West. 21.08 Length West to End of Foundation 43.5 Total 124.5 Page 35 of 123

TSD 14-016 Revision 0 Each Unit has Service Water supply lines A65 2SW-243-3 parallels the Unit 2 Station Air line A66 2SA-012-1 1/2 in Table 28. The exceptions are that the elevation at R is 5707 and the vertical rise is to the 584 elevation making that segment 135. The distance west to the bend from the vertical is 9 further at 286.

The distance of the penetration from column 17 is 39+110+14+11+9+9+9 or 103 instead of 910 for A66 making the length of the segment south from the bend 216. The length west to the end of the foundation is 9 shorter or 429. The segment lengths are summarized in Table 35.

Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths A65 2SW-243-3" Section Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 28.5 South from Bend Past S to Bend West. 21.50 Length West to End of Foundation 42.75 Total 124.67 The Unit 2 Aerated Drain line A62 2AD-146-4 parallels the path of the Service Water 2SW-243-3 over much of its length. It runs next to 2SA-012-1 1/2 whose segment lengths are shown in Table 34. The length to the vertical is 186. As seen in Figure 8, the penetration is at the 5707 Figure 20 shows the elevation of the vertical at 584 making the length 135. The pipe then runs west to where it bends north. The distance west is 9 less than 2SA-012-1 1/2 length or 27. The penetration at R is 39+110+14+11+9+9 or 96 to column 17. The additional length is26-149 or 113 for a total length of 209 feet. It then proceeds west 69 to match line X and 25-26 or 226 for a total length of 293. The distance from the bend south to the penetration is 149+2 or 169. The vertical segment to 588 elevation is 4 feet. The pipe section lengths are summarized in Table 36.

Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths A62 2AD-146-4 Section Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 27 South from Bend Past S to Bend West. 20.75 Length West After Bend 29.25 Length South 16.75 Vertical to 588' 4 Total 129.67 As seen on Figure 8, there is no ODW-008-3 line at the Unit 2 penetrations at R. There is a 2DW-014-3 and a 2DW-008-3. There appears to be incorrect labeling of the lines on M-107 Sheet 2 as seen in Figure 22 since 2DW-014-3 and 2DW-008-3 cannot be the same line and have two different penetrations at R21 in Figure 8.

Page 36 of 123

TSD 14-016 Revision 0 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2 Therefore, the lines segment lengths will be assigned to the 2DW-014-3 and 2DW-008-3 as shown in Figure 22. Both lines run parallel to 2AD-146-4. Both are 186 to the vertical. 2DW-014-3 is at the 5707 elevation at match line R and 2DW-008-3 is at the 5694 elevation as shown on Figure 8. They are both assumed to be at the 583 elevation as indicated in Figure 13 which shows two 3 lines at K1-K1. This results in a vertical rise length of 125 for A63 2DW-014-3 and 138 for A61 2DW-008-3. The 2DW-008-3 segment west from the vertical rise to the bend south is 9 shorter than 2AD-146-4 at 263. 2DW-104-3 is an additional 9 shorter at 256. As seen in Figure 8, 2DW-014-3 is 9 closer to column 17 that 2AD-146-4 or 20 2DW-008-3 is 39+17+9+16+9+9 or 91 with an addition 26-149 from column 17 this makes the length 204. From the bends, south the lines turn west for a length where 2DW-014-3 is 9 shorter than 2AD-146-4 or 286. 2DW-008-3 is 9 shorter than 2DW-014-3 or 279. The length south to the vertical leading to the floor penetration is the same as 2AD-146-4 or 169. The vertical to the 588 foot elevation is 5 feet. The calculated line segment lengths are provided in Table 29.

Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths A63 2DW-014-3 A61 2DW-008-3 Section Length Feet Length Feet Length to Vertical West 18.5 18.5 Vertical to 583' 12.42 13.67 Length West to Bend South 25.5 26.25 South from Bend Past S to Bend West. 20.00 20.33 Length West After Bend 28.5 27.75 Length South 16.75 16.75 Vertical to 588' 5 5 Total 126.67 128.25 OCT-61-2 at penetration A58 parallels 2DW-014-3 for most of its length but appears to terminate outside the SFB wall. It is the line from the Decontamination Pad to the Chemical Drain Tank making it a MARSSIM Class 1 line.

Page 37 of 123

TSD 14-016 Revision 0 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination It is 186 to the vertical bend. As seen on Figure 8, A58 OCT-061-2 is at the 5694 at the match line R penetrations making the vertical to the 583 138. The westward run to the bend south is 9 shorter than 2DW-014-3 or 279 long. As seen in Figure 8 it is 9 closer to column 17 than 2DW-008-3 or 84 which makes the total length with 26-149 added a total of 197. The distance west to the termination of the line segment is 4 x 9 or 3 with an additional 3+3.75+3.5 as seen in Figure 23 for a total of 133. The calculated segment lengths are provided in Table 38.

Table 38 - A58 OCT-061-2" Line Segment Lengths A58 OCT-061-2 Section Length Feet Length to Vertical West 18.5 Vertical to 583' 13.67 Length West to Bend South 24.75 South from Bend Past S to Bend West. 19.58 Length West After Bend 13.25 Total 89.75 Page 38 of 123

TSD 14-016 Revision 0 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path As seen in Figure 24, the Unit 2 Waste Discharge line A64 OWD-059-2 1/2 parallels OCT-061-2. As shown in Figure 8, the line is at the 5707 elevation at the penetrations at R17. The distance to the vertical bend is 186. The pipe rises from 5707 elevation to the 584 elevation or 135. The section west is 9 shorter than OCT-061-2 or 24. The penetration is 9 closer to column 17 than 2DW-014-3 or making the total length of the south running segment 193. The segment west to the second bend south is 5 x 9 or 39+3+39+14+3 or 276. It then travels west to the vertical bend to the penetration 149+176+123 or 446. The vertical to the 588 is 4 feet. The pipe section lengths are summarized in Table 39.

Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths A64 OWD-059-2 Section 1/2 Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 24 South from Bend Past S to Bend West. 19.25 Length West After Bend 44.5 Vertical to 588' 4 Total 123.67 As seen in Figure 25, the remaining Unit 2 lines all run parallel to OWD-059-2 1/2 and terminate in the same area. A57 0SF-012-3", A55 2SF-008-2", A56 2SF-022-3".

Page 39 of 123

TSD 14-016 Revision 0 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout Figure 26 from excerpted from drawing M-63 shows that 0SF-012-3"feeds the Auxiliary Building Hold-Up Tanks (HUTs), 2SF-008-2" provides water to the Spent Fuel Pool supply and return from the Unit 2 Refueling Water Storage Tank, and 2SF-022-3" to the Unit 2 Spent Fuel Water Demin making all these lines Class 1 MARSSIM lines.

Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines Page 40 of 123

TSD 14-016 Revision 0 As seen in Figure 20, each line is 186 from the penetrations at R17 to the vertical bend. As seen in Figure 8, the penetrations are on the same elevation as OCT-061-2 and like OCT-061-2 rise to the 583 elevation or 138. 2SF-008-3 has a length west from the vertical that is 9 shorter than OCT-061-2 or 24. The west segment length from the vertical of 2SF-022-3 is 9 shorter than 2SF-008-2 at 233 and OSF-012-3 is 26 shorter than 2SF-008-2 or 209. As seen in Figure 8, A55 2SF-008-2 is 9 closer to column 17 than OCT-061-2 or 1810 when the 113 from column 17 is included. 2SF-022-3 is 16 closer to column 17 than 2SF-008-2 or 174. OSF-12-3 is 9 closer than 2SF-022-3 or 167. As seen in Figure 25, the lengths west after the first bend south for OSF-12-3 is 26 +6+3+39+3 or 183. 2SF-22-3 is 6+3+39+3+9 or 166 and 2SF-008-2 is 6-9+3+39+3+9+9 for 166 also. The length south to the vertical to the penetrations is the same length as 2CC-078-10 and 2CC-080-10 or 169 and the vertical from the 583 to 588 is 5. The pipes segment lengths are summarized in Table 40.

Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3" A55 2SF-008-2 A56 2SF-022-3 A57 0SF-012-3 Section Length Feet Length Feet Length Feet Length to Vertical West 18.5 18.5 18.5 Vertical to 583' 13.67 13.67 13.67 Length West to Bend South 24 23.25 20.75 South from Bend Past S to Bend West. 18.83 17.33 16.58 Length West After Bend 16.5 16.5 18.25 Length South to Floor Pen Vertical 16.75 16.75 16.75 Vertical to 588' 5 5 5 Total 113.25 111 109.5 The Containment to Auxiliary Building pipe chase penetration shown in Figure 1 are already attributed to the Containments whose walls form the interior wall of the Auxiliary Building Pipe Chase as well. The Containment Sump piping at M-16 and M-24 in Figure 3 are also attributed to the Containment. The next penetration is a 14 inch sleeve through the 2 foot thick wall between the Aux Building and a Main Steam Tunnel at the 571 elevation as seen on Attachment B near row H column 10. There is a similar sleeve on the opposite wall at H30. As seen on Attachment B, there is a 10 inch Fire Protection Line OFP-12-10 at H10 that is shown on Drawing M-165 and M-187. Near G10 there are two OSW-008-12 lines as seen on drawing M-185 and Attachments A & B.

As seen on Attachment A and B there are many penetrations along the wall at Row G between the Turbine Building and Auxiliary Building. All penetrations labeled as open sleeve are assumed to have the pipe removed, leaving an opening equal to the outer diameter of the pipe. Attachment B shows penetrations at G13 consisting of a 3 waste disposal line OWD-31-3 from Drawing M-165 and M-171.

There are two 12 Service Water Supply lines to the Diesel Generator Heat Exchangers at J9 A27, A28 and J31 A30, A31as seen on Attachments A and B. As seen in Figure 27, these lines pass under the steam tunnels for 21 feet, then under the tunnel floor towards G for 143 and 1`23 plus the 219 of H to G. Detail C of M-106 (provided as Figure 28) shows an elevation change from 554 9 and 5534 at G to 567 6at J. This is an additional 142 and 129 making the total lengths of the lines 71 2 and 69 9 or 837 and 833 inches respectively. As seen in Figure 28, the horizontal runs under the Main Steam Tunnel are at 5636, the floor is at 570 so the pipes are 66 below the floor in the fill material below the slab. The horizontal run under the Diesel Generator floor are at the same elevation with the floor at the 5676. The pipes horizontal runs are 4 feet below the floor. Thus, none of the horizontal runs of A27, A28, A30, or A31 are with 8 of the surface of any floor.

Page 41 of 123

TSD 14-016 Revision 0 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106.

Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers Attachments A & B show the 48 in Service Water Supply penetrations C26 and C29. As seen on drawings M-168 and M-169 two 48 inch Service Water Supply Header pipes, OSW-13-48 (C29) and OSW-14-48 (C26), exit the Auxiliary Building at elevation 5498 at G19 and G21. As shown on Figure 39 excerpted from M-103 and M-104 the pipes run east 104 beneath the 560 floor from G to A through the Turbine Page 42 of 123

TSD 14-016 Revision 0 Building slab where they exit the Turbine Building Oil Room wall at A19 and A21 at 5498 as seen in Figure 38. Figure 48 shows that they exit the Turbine Building slab 6 feet before match line A. Thus, the distance from G to the slab exit is 171.5 feet as seen on Figure 39. They then travel 8 feet east to the pipes center line of the vertical rise. They then rise vertically from 5498 to the 579 elevation (i.e., 294) making the buried pipe length 37 4. The pipes continue eastward to the Crib House wall as seen on M-106 and Figure 48. As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 579 will be cut and removed leaving the buried vertical sections. Drawing M-105 shows the lines traversing east where they pass through the Crib House wall at AA19 and AA21. M-106 and Figure 38 shows it is 2 feet from the center line of the pipe to A. M-105 shows the distance from A to AA as 50 feet for a total of 52 feet that will be removed. M-106 and M-105 shows the Crib House wall to be 4 feet as seen in Figure 48.

Table 41 - Service Water Supply Header Pipe Lengths C26 & C29 OSW-013-48" and OSW-14-48" Segment Category Drawing Feet Auxiliary Wall Column G Embedded M-103, M-104 1.5 Column G to TB Slab Exit Near Column A Embedded M-103, M-104 170 East to Vertical Rise at Column A Buried M-106 8.00 Vertical Rise at Column A Buried M-106 29.33 Totals 208.8 Embedded 171.5 Buried 37.33 The 4 foot penetration length in theCrib House foundation is included in the Crib House Section.

The Auxiliary Building Aerated Drains remaining in the slab were surveyed and had their lengths measured in Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016 (4).

Because the inventory of Auxiliary Building Penetrations also includes those coming from the Unit 1 and Unit 2 Containments, a breakout list of the inventory which is a subset of the Attachment F complete inventory is provided in Attachment I. A summary of all the Auxiliary Building penetrations including those covered in the containment sections for both Units are provided in Table 42.

Table 42 - Summary of Auxiliary Building Affiliated Penetrations Sum of Length Sum of Int SA Sum of Void Space Category, End State meters m2 m3 Bld to Bld Pen 482.89 585.06 72.34 Buried Pipe 126.32 92.68 6.74 Open Sleeve 199.54 256.67 37.44 Pipe in Sleeve 157.02 235.71 28.16 Bld to Yard Pen 924.37 363.69 161.87 Buried Pipe 924.37 363.69 161.87 Grand Total 1407.26 948.75 234.21 Page 43 of 123

TSD 14-016 Revision 0 4.5. Turbine Building Penetrations and Piping As seen on Attachment B and Figure 29 there are 10 diameter Fire Protection line penetrations in the north and south wall of the Diesel Generator Buildings at 583 6 at J5 and J35 as show in Drawing M-106. These lines and penetrations are part of the buried pipe inventory. (5)

Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106 The pipes are assumed to be cut flush with the interior and exterior of the 3 foot thick Diesel Generator Building north and south walls.

Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall Section Length feet Elevation Pen 35 Sleeve 3 583.5 Pen 36 Sleeve 3 583.5 Page 44 of 123

TSD 14-016 Revision 0 There are 4 inch diameter Diesel Oil lines 2DO-006-4 (T68) and 1DO-001-4 (T75) that go through the Turbine Building North and South Walls at G5 and G35 at the 5853 elevation. M-104 show T68 going through a 4 foot thick wall, then traveling buried 45 6 to a where it bends 2 feet East it then rises out of the ground to the 593 elevation. The pipes are to be cut flush with the exterior anterior of the wall laving 4 foot lengths.

Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104 Page 45 of 123

TSD 14-016 Revision 0 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103 Drawing M-104 shows three 8 sleeves through the 18 wall between the Turbine Building and Unit 2 Diesel Generator Building at G5-G10. Drawings M-562 and M-663 show only two oil lines 2DO-004-4" (T69) and 2DO-001-4" (T70) going through the penetrations. Although there appears to be no pipe through the sleeve at T70a, it is included in the inventory.

Page 46 of 123

TSD 14-016 Revision 0 Figure 32 - Unit 2 North Diesel Oil Penetrations There are three Unit 1 oil lines between G32-34 in M-103 and M-214. These are penetrations T72, T73, T74.

Figure 33 - Unit 1 South Diesel Oil Penetrations Page 47 of 123

TSD 14-016 Revision 0 These are routed through the 18 thick wall between the Diesel Generator and Turbine Building in 8 sleeves. M-104 shows 3 8 sleeves between G32 and G35. The pipes will be removed leaving the 8 sleeve openings.

As seen in Figure 27 there is also a 14 diameter sleeve passing through the Diesel Generator Building and Steam Tunnel walls between H&J at columns 10 and 31 (T34b, T34a). As seen on Attachments A and B the walls are 2 feet thick.

The 16 Service Water Return lines T32 and T33 from the Diesel Generator Heat Exchangers are also embedded below the Diesel Generator Building floors as seen in Figure 27. These connect to the 48 Service Water Supply Header on Drawing M-103 and M-104. A graphic with dimensions for U1 T32 pipe is provided as Figure 34.

Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers As seen on M-106 the Diesel Generator Floor is at 5676 and the pipe below it is at 5636 resulting in a vertical rise to the floor penetration at J31 and J9. The horizontal run is 4 feet below the Diesel Generator Building floor. There is also a vertical rise at G31 and G9 from 55310 to 5636 or 9.67 feet. The line runs north under the Turbine Building floor at 55310 which is 62 below the 560 elevation floor. The length from J to G is 42. M-106 shows the floor penetrations at J31 and J9. T32 at J31 is 3+19+ 22 3/8 from J resulting in a length of 35.05 feet. T33 at J9 is inset 3+19+111 from J for a length of 35.33 feet. The runs eastward and north south are found on M-106, M-103, M-104. These total lengths are 183 feet as seen in Table 44. The portion of the pipe under the Diesel Generator building is below the slab in soil.

Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33 T32 U1 T33 U2 Segment Feet Feet Page 48 of 123

TSD 14-016 Revision 0 Vertical 1 Under DG 4 4 Vertical 2 Under DG 9.67 9.67 Length on M-106 35.05 35.33 Length East on M-103 & M-104 16 16 Length North South on M-103 & M-104 118.75 118.75 Total Length 183.5 183.8 All the penetrations on the East Wall of the Turbine Building are concentrated in and around the Oil Room at the centerline of the building. The Unit 2 north penetrations are provided on M-104 and an excerpt from the drawing is provided as Figure 35. The Unit 1 south penetrations are provided on M-103 an excerpt from the drawing is provided as Figure 37. The buried portions of these pipes will be removed with the exception of the 48 inch Service Water Headers C26 and C29, the 20 inch and 4 inch Condensate pipes T103 and T105.

These include spare, 10, 12 and 14 spare penetrations at C16 (T91, T92, T93) and C24 (T99, T100, T101) as seen on Attachments A and B as well as Figure 35 and Figure 37. As seen in Figure 35, Figure 37, and Detail B of M-106 the spare penetrations are 5 feet long extending 6 inches past the 4 foot thick wall on either side. The remaining pipes are assumed to be cut flush with the interior and exterior walls leaving 4 feet of embedded pipe. M-104 shows T102 and T95 running at the 5569 elevation to match line D.

Page 49 of 123

TSD 14-016 Revision 0 Figure 35 - Turbine Building East Wall Penetrations - North Page 50 of 123

TSD 14-016 Revision 0 Figure 36 - T95 and T102 Buried and Embedded Sections As seen in Figure 36, the embedded portion of T95 from the exterior of the wall at the back of the Oil Room to the penetration through the 560 elevation floor is 10+25+354+26 or 7210. The vertical through the 560 floor is 560-5569 or 33. T95 then travels an estimated 13 feet in the Page 51 of 123

TSD 14-016 Revision 0 soil until it rises vertically from the 5569 to the 586 elevation of 118.33 feet as seen in Table 45.

The embedded length of T102 2 foot of wall + 354+26 or 3910.

Table 45 - Estimated Lengths of T95 and T102.

Line Segment T95 T102 560' Vertical from 556'9" 3.25 3.25 560' Pen to Back of TB 72.8 39.8 Back Wall To Vertical in Soil 13 6 Vertical to 586' in Soil 29.25 29.25 Total 118.33 78.33 Embedded 76.08 43.08 Buried 42.25 35.25 Figure 37 - Turbine Building East Wall Penetrations - South A 20 inch Condensate line and a 4 inch Condensate Pump Recirc line penetrate the wall at A21 5569 and 5583 elevation as shown on M-105 and M-103. The 20 inch Condensate Line supplies the Alternate Feedwater Pumps as shown in drawing M-105 Sheet 2 Section C-C. The pipe exits from the Turbine Page 52 of 123

TSD 14-016 Revision 0 Building slab at elevation 5569 into the soil then travels vertically to the 586 elevation. This line is not included in the TSD 14-015 Attachment 1 listing of buried pipe. M-103 and M-106 Section A-A show the top view and the side view of the pipe existing the Turbine Building these sections are provide in Figure 38.

As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 586 will be cut and removed leaving the buried vertical sections.

Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building Drawing B-559 shows the Oil Room wall exterior is 11 feet from row B which is 14 feet from Row A. As seen in Figure 38, the pipe exits the building at a 45 degree angle this means the pipe exiting the building foundation then bends 90 degrees upward at two feet from Row A. This results in a 69 base and 12 height resulting in a hypotenuse length of 13.77 feet from the 20 to 18 reducer within the wall to the vertical bend upward to the 586 elevation. The vertical pipe length from the 5569 to 586 or 29.25 feet. The buried pipe section of the Condensate from the exit of the Oil Room foundation to the cut line is shown in Table 46. The 4 Condensate line parallels the 20 line but exits the foundation 1.5 feet higher at 5583 or 19 below the 560 floor. Resulting in a vertical length of 279. As seen in Figure 39, the embedded portion in the TB foundation is shown on M-103. Shortly after entering the Turbine Building foundation they run through the slab and emerge on the west side of the 560 floor at G22. M-103 shows 180 feet from column A to G. The 18 T103 penetration is 56 below G making it 1746 long. Other dimension show the distance from the centerline of the pipe forming a 45 degree triangle at 129 long.

Page 53 of 123

TSD 14-016 Revision 0 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105 Page 54 of 123

TSD 14-016 Revision 0 This results in a length of 1619 from A to the 45 degree bend for the 18 pipe. The 4 inch pipe is offset by 2 feet from the 18 pipe resulting in a length of 1599 from A to the 45 degree bend. The 45 degree bend section of each pipe is the hypotenuse of a 45 degree triangle with 129 sides or 18.03 feet. The 4 inch diameter pipe vertical section to the floor is 19 and the 18 pipe vertical section is 33. The lengths, diameters, surface areas and volumes are summarized in Table 46. As seen in Figure 39, the 4 Condensate line T105 runs beneath the floor at the 5583 elevation making it 19 below the floor. The 18 Condensate line T103 runs under the floor at the 5569 elevation making the top of the pipe at the 5576 elevation or 26 below the floor. T106 runs under the floor at the 5569 level, 33 below the 560 floor.

Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes Length ft SA ft2 Vol ft3 T103 20" T105 4" Buried Pipe Section Feet Feet 20" 4" 20" 4" Wall thickness Inches 0.594 0.237 Diameter feet 1.57 0.29 Wall to 90 13.77 13.77 67.81 12.71 26.58 0.93 Vertical 29.25 27.75 144.06 25.62 56.46 1.88 Total Buried 43.02 41.52 211.86 38.33 83.03 2.82 Embedded Pipe Section 18" Feet 4" Feet 18" 4" 18" 4" Wall thickness Inches 0.562 0.237 Diameter feet 1.41 0.29 Horizontal 161.75 159.75 714.63 147.47 251.25 10.83 Hypotenuse 18.03 18.03 79.66 16.64 28.01 1.22 Vertical 3.25 1.75 14.36 1.62 5.05 0.12 Total Embedded 183.03 179.53 808.66 165.73 284.31 12.17 Totals 226.05 221.05 1020.52 204.05 367.34 14.99 Page 55 of 123

TSD 14-016 Revision 0 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103 The 48 Service Water Supply Headers exiting between B & A at Columns 19 and 21 from under the building at 549 are discussed in the Crib House section.

Aerated Drain piping from equipment drains, floor drains, and sump piping remains in the end state Turbine Building slab below the 560 elevation. The estimated piping lengths and diameters were inventoried in the preparation of FSS Plan 06105B Turbine Building Embedded Piping Drawings used in developing the FSS Plan are as follows: (6)

B-452 Turbine Building Plumbing Basement Floor Plan Unit 1 B-454 Turbine Building Plumbing Diagram Basement Floor Plan Unit 1 B-471 Turbine Building Plumbing Basement Floor Plan Unit 2 B-473 Turbine Building Plumbing Diagram Basement Floor Plan Unit 2 M-103 Zion Station Unit 1Turbine Building Piping, Misc. Piping in Structure Embedded system piping surveyed by this survey plan included the floor drain and equipment drain systems below the 560 elevation of the Turbine Building. These systems consist of inputs and connecting piping that terminates at one of four drain sumps (Unit 1 Equipment Sump, Unit 2 Equipment Sump, Turbine Building Floor Sump and the Fire Sump) beneath the 560 el. floor.

The floor drain system on the 560 el. consists of 26 floor drain inputs, the floor drains from the Clean and Dirty Oil Storage Tank Rooms, the continuation of the Emergency Diesel Generator Fuel Oil Storage Tank Room floor drains from the 567 el., and the continuation of the floor drain systems from the Turbine Building 592, 617 and 642 elevations from where they enter the floor of the 560 el. to their connection to Page 56 of 123

TSD 14-016 Revision 0 the embedded drain piping (approximately 1,250 linear feet of varying diameter drain pipe which connects all floor drain inputs) and terminating at either the Turbine Building Sump or the Fire Sump.

Also included is the Unit 1 equipment drain system consisting of input associated with components located on the 560 and 562 elevations and the common area between Units 1 and 2, the continuation of the Unit 1equipment drains from the 642, 617, and 592 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 300 linear feet of varying diameter equipment drain system piping) terminating at the Unit 1 Equipment Sump.

Also included is the Unit 2 equipment drain system consisting of input associated with components located on the 560 562 elevations, the continuation of the equipment drains from the 642, 617 and 592 elevations of Unit 2 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 200 linear feet of varying diameter equipment drain system piping) terminating at the Unit 2 Equipment Sump.

The polishing filter system drains consist of 2 inputs located in the common area, connected to 2, separate 10 diameter pipe systems that terminate at inputs to the fire sump, total length of 10 diameter pipe is approximately 180 linear feet.

The varying pipe diameters are apparently related to progression in the number of inputs to the different systems (more inputs, increased pipe diameter). The surveys were performed at the discharge end of the pipes in the sumps. During performance of the survey, pipes were found to be larger in diameter than what was identified in the survey plan based on available drawings (6vs 4 and 8vs 6).

The estimated length of pipe was based on the drop from the 560 el. to the lateral pipe run (approximately

4) plus the estimated lateral run of the pipe base on turbine building column line dimensions, as the drawings are difficult to read. In some cases, the total length of a given diameter of pipe could not be determined consequently an exaggerated total length was used in order to build conservatism into the survey plan.

The estimated pipe section diameters and lengths are summarized in Table 47.

Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping Penetration Pipe Size Length No. Description inches OD Feet T147 U-1 Equip Drain Sump, 6 pipe West Wall 6 200.00 T148 U-1 Equip Drain Sump, 6 pipe North Wall 6 100.00 T149 U-2 Equip Drain Sump, 6 pipe West Wall 6 200.00 T150 Floor Drain Sump, West-most 6 pipe on North Wall 6 100.00 T151 Floor Drain Sump East-most 6 pipe on North Wall 4 100.00 T152 Fire Sump, South-most 6 pipe on West Wall 4 150.00 T153 Fire Sump, North-most 6 pipe on West Wall 8 450.00 T154 Fire Sump, West-most 8 pipe on North Wall 8 450.00 T155 Fire Sump, West-most 10 pipe on North Wall 10 80.00 T156 Fire Sump, East-most 10 pipe on North Wall 10 100.00 The list of Turbine Building affiliated penetrations and piping other than the drains is provided in Attachment J. The calculated lengths, surface areas and void spaces are summarized in Table 48.

Page 57 of 123

TSD 14-016 Revision 0 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes.

Sum of Sum of Length Sum of Int SA Void Space Category, End State meters m2 m3 Bld to Bld Pen 291.56 354.61 43.79 Buried Pipe 204.69 222.34 19.46 Open Sleeve 86.87 132.27 24.33 Bld to Yard Pen 235.59 726.53 13.46 Buried Pipe 158.58 683.81 11.42 Open Sleeve 4.57 4.27 0.32 Pipe in Pen 72.44 38.45 1.72 Grand Total 527.15 1081.14 57.24 The Turbine Floor drain piping is summarized in Table 49. The inventory of piping is provided at the end of Attachment J.

Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes Category, End Sum of Length Sum of Int SA Sum of Void Space State meters m2 m3 Bld Pen 588.26 302.43 13.13 Embedded Pipe 588.26 302.43 13.13 Grand Total 588.26 302.43 13.13 4.1. Circulating Water Intake Piping The Circulating Water Supply to the Condensers consist of embedded pipe through the Crib House Wall, buried pipe from the Crib House to the Turbine Building Foundation and Embedded pipe from the Turbine Building foundation as seen in Attachment C. The section below the condensers is shown in Figure 41.

Assuming the 9 foot diameter supply pipes (T109, T110, T120, T121 in Unit 1 and T123a, T123, T133, T134 in Unit 2) are cut above the water table at the 580 elevation and grouted. The floor elevation is 572. The average length to the 12 foot diameter line below 572 to the connection to the 12 foot diameter pipe is conservatively estimated at 26 since some of the surface area extends below the top of the pipes at the 570 elevation. Thus, their total embedded length is 2.5 feet. Notation on M-100 which is retained in Attachment C shows a 1 inch pipe wall thickness for the 9 diameter piping.

The 36 diameter manways to the 12 Diameter Circulating Water Supply line (T83, T85, T87, T88) are 9 feet long if they are cut flush with the concrete as seen in in Figure 41. Figure 41 also shows that each of the four (T111, T122, T143, T124) 12 foot diameter pipes below the condenser. These pipes have a 1.25 inch wall thickness as seen in M-100.

Page 58 of 123

TSD 14-016 Revision 0 Figure 41 - Circ Water Intake Supply to Condensers Each of the 4 pipes has a spherical head whose surface area is calculated using Equation 3.

Equation 3 - Surface Area of Spherical Cap

= 2 Where; r = is the inner radius or 70.75 inches h = is the inner height of 22.75 inches This results in an inner surface are of 10,113.18 square inches for each end bell.

The volume is calculated using Equation 4.

Page 59 of 123

TSD 14-016 Revision 0 Equation 4 - Volume of Spherical Cap

= (32 + 2 )

6 Where a equals the inside radius or 70.75 inches and h the inside height or 22.75 inches. The end cap surface areas and volumes are shown in Table 50.

Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers End Bell Pipe Totals Length Section r inches h inches SA in2 V in3 inches SA in2 V in3 SA in2 V in3 T111 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T111b 70.75 270 1.2002E+05 4.2459E+06 1.2002E+05 4.2459E+06 T122 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T122b 70.75 1002 4.4542E+05 1.5757E+07 4.4542E+05 1.5757E+07 T143 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T143b 70.75 1002 4.4542E+05 1.5757E+07 4.4542E+05 1.5757E+07 T124 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T124b 70.75 270 1.2002E+05 4.2459E+06 1.2002E+05 4.2459E+06 Drawing B-61 shows a distance of 316 from match line E to the Turbine Building wall just beyond match line D. The embedded length of T111, T122, T143, T124 are as seen on Attachment C. The lengths embedded in concrete are 316+ 87.5 + 56 or 457.5 which is 547.5 inches. As seen on Attachment C the buried portions of pipes T111 and T124 are 54-316 or 367.5 which is 270 inches. The lengths of T122b and T143b are 115-316 or 1002 inches.

Section T112 and T125 cut diagonally South and North Section 4-4 on drawing M-100 provides a side view of the intersection with a 9 long expansion to a 17 foot diameter. M-100 shows the dimension from T111 to the intersection below is 115 minus 54 feet or 61 feet with an estimated 4 feet to the intersection below the joint for an opposite length of 65 feet. The base length is also shown on M-100 as 65 7.75 inches. This results in a hypotenuse length of 925. Minus 14 to the 17 expansion and 9 for the expansion joint provides a length of 695.

Page 60 of 123

TSD 14-016 Revision 0 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127 The average outside diameter of the expansions at T113 and T126 is 146 with a 1.5 inch wall thickness this is an interior diameter of 143 over a 9 length.

Sections T114 and T127 are 17 OD pipes with 1.5 walls for an inner diameter of 169. M-100 shows the base is 88 4.25 inches minus 162 or 722.25. It shows an opposite of 50 feet minus the estimated 4 feet for the upper point and an estimated 10 feet for the lower point equaling 36. The resulting hypotenuse is 808. As seen on section T114 of Attachment C there is an addition 14 to the 12 to 17 expansion for a total length of 948.

The 17 to 9 reducers at T115 and T128 are approximately 83 long with an average diameter or 13. With a pipe wall thickness of 1 the average inside diameter is 1210. The length of the straight sections is estimated at 6 feet with a 9 foot outside diameter and 810 inside diameter.

Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128 Wall Length Sect Dia in Thick ID in SA in2 V in3 Reducer 156 1 154 99 4.79E+04 1.84E+06 Straight 108 1 106 72 2.40E+04 6.35E+05 Total 171 7.19E+04 2.48E+06 T116 and T129 are approximately 196 long. T117 and T130 are approximately the same length as T115 and T128 at 171 inches long. T118 and T131 are 10 to 9 reducers that are 83 long. T119 and T132 are approximately 14 feet long and have a 10 foot outer diameter.

There are Circulating Water Intake Pipes that connect to the Forebay Drawing B-49 shows a 16 diameter at the exit point from the Forebay. Drawing M-2 shows approximately 50 feet to the shoreline.

Page 61 of 123

TSD 14-016 Revision 0 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2 The summary of the Circulating Water Intake and Supply section noted above and shown in Attachment C have inventories listed in Attachment O. The lengths, surface areas and void space volumes are summarized in Table 52.

Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes Sum of Length Sum of Int SA Sum of Void Space Category, End State meters m2 m3 Circ Water Intake 384.27 4412.09 4393.19 4.2. Circulating Water Discharge Piping Circulating Water Discharge piping in the Turbine Building consists of a 48 inch (T75, T76) and 36 inch stand pipe (T84, T86), a 36 inch manway entrances to the Discharge Tunnel (T135, T136) and two 12 foot interior diameter discharge pipes from the condenser for each Unit (T77, T78, T80, T81). The top view is provided in drawing M-15, the side view is from drawing B-100 as shown in Figure 44 and in Figure 45.

Penetrations T75and T77 are the Unit 2 Circulating Water Discharge Stand Pipe located at F9 and F31 in the Turbine Building as shown in Attachments A, B, C and Figure 44. A side view is provided in Figure 45 from B-100. It can be seen that the pipe runs vertically through the Turbine Building slab from the 592 to 22 above the 5616: elevation at the middle of the 45 degree bend into the discharge tunnel. The vertical drop will be from the 588 elevation to the 5638 elevation. This makes the vertical section 24 4 long as seen in Figure 45. The base of the triangle formed by the slanted section from the Discharge Tunnel wall to the center of the pipe is 108. The vertical drop is 136 this results in a hypotenuse of 14.27 feet forming an overall length of 42.6 feet.

Page 62 of 123

TSD 14-016 Revision 0 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel Page 63 of 123

TSD 14-016 Revision 0 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100 Table 53 - 48 Inch Circulating Water Standpipe Lengths Length Pipe Section Length Feet Inches Vertical from 592' 24.33 292 Slant Base 10.67 Slant Opp 13.5 Hypotenuse 14.27 171.22 Overall Length 38.60 463.22 The 36 diameter standpipes are vertical and embedded from the 588 elevation to the top of the Discharge Tunnel at 5586 (i.e., 5626-3). This results in a length of 296 for each pipe T135 and T136. B-100 shows that the 12 diameter for the Circ Water Discharge lines is an inside diameter and that they are Page 64 of 123

TSD 14-016 Revision 0 embedded in 5 feet of concrete. It also shows that the 36 access hatch is 1 foot off the floor. Assuming the hatch will not be cut flush to the floor, this results in a 4 foot length.

Each Discharge Tunnel ends at a Valve House near the sheet piling wall as seen on Attachment C. Drawing B-39 shows a 14 diameter Discharge Pipe that travels to the Discharge Diffuser structures in the lake.

Drawing M-2 shows that the distance to the shoreline is bounded at 50 feet. The east west 50 foot dimension is transposed from another part of the drawing as seen in Figure 43.

M-100 shows a 14 diameter pipe has a 0.750 inch wall thickness for the Discharge Pipes.

Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100 The estimated lengths, volumes and interior surface areas of the Circulating Water Discharge Piping are summarized in Error! Reference source not found..

The 48 Service Water Return Line T82 in Unit 1 and T79 in Unit 2 runs through the Turbine Building slab at 55310 elevation as seen on M-103 and M-104 and the excerpt provided as Figure 47. It empties into the Discharge Tunnel.

Page 65 of 123

TSD 14-016 Revision 0 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return The side view of the T82 line entering the Unit 1 Discharge Tunnel is shown in Figure 45 which excerpted from drawing B-100. The Unit 1 T82 dimensions are provided on M-103. The distance east from where it enters the Discharge Tunnel is 138+6 or 198. The line then runs north from Column 31 to Column 20 where it joins the Unit 2 line T82. The north runs distance to column 20 is 31-43+25+273+273+219+219 or 1499. The section that Ts off the north line to the floor penetration at G23 is 134+16-5 or 24 4. The vertical rise from the 55310 to the floor at 560 is 62.

The T82 segment lengths are summarized in Table 54.

Page 66 of 123

TSD 14-016 Revision 0 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths Section Drawing Feet Unit 1 Disch Tunnel East M-103 19.67 Unit 1 Disch Tunnel North M-103 149.75 Unit 1 Disch Tunnel East M-103 24.33 Unit 1 Vertical to Floor at G23 M-103 6.17 Total 199.92 The T79 Unit 2 pipe segment lengths are shown on drawing M-104. They are the same dimensions with the exception that M-104 has more length on the southward segment to column 20 where it joins T82 than M-103 has at 31-43+25+273+273+219+219 or 1499.

Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths Section Drawing Feet Unit 2 Disch Tunnel East M-104 19.67 Unit 2 Disch Tunnel South M-104 149.75 Unit 2 Disch Tunnel East M-104 24.33 Unit 2 Vertical to Floor at G16 M-104 6.17 Total 199.92 As noted above, both T79 and T82 run under the floor at the 55310 elevation or 62 below the 560 Turbine Building floor. The piping sections inventory for Circulating Discharge Piping are provided in Attachment P. The Circulating Water Discharge piping lengths, surface areas and volumes are summarized in Table 56.

Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay Sum of Length Sum of Int SA Sum of Void Space Category, End State meters m2 m3 Circ Water Discharge Pipe 202.40 1074.86 666.09 4.3. Crib House Penetrations and Embedded Piping The estimated pipe section lengths and for the Circulating Water Intake piping shown in Attachment C are described in Section 4.1. As seen in Figure 48 there are two 10 diameter Fire Protection lines OFP-011-10 that pass through the Crib House wall at 5859 C1 and 5819 C7. All the pipes will be cut flush to the interior and exterior walls making them 4 feet in length.

Page 67 of 123

TSD 14-016 Revision 0 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2 There is also a 3" Hot Water Supply OHS-020-3, 3" Hot Water Return OHS-024-3", and 3 Filtered Water line OMU-031-3 at the 5816 elevation. At the 581 elevation there is a 2 Station Air and a 3 Control Air OSA-002-3". Each of these lines will also be cut flush with the exception of the Filtered Water line are within 6 inch sleeves. The inventory of Crib House penetrations is provided in Attachment L. The pipes in the sleeves will be removed leaving the opening of the sleeve. The estimated overall surface areas and volumes using the pipe ID or sleeve IDs is provided in Table 57 Table 57 - Summary of Crib House Penetrations at Match Line AA Sum of Category, End State Length Sum of Int Sum of Void Space meters SA m2 m3 Bld to Yard Pen 10.97 1.14 2.92 Open Sleeve 4.88 0.19 0.09 Pipe in Pen 6.10 0.95 2.83 Grand Total 10.97 1.14 2.92 Page 68 of 123

TSD 14-016 Revision 0 4.4. Waste Water Treatment Facility Penetrations and Buried Piping The Waste Water Treatment Facility has eight subsurface penetrations as shown in Figure 49 and Figure 50.

The pipe in the yard and the interior of the building will be cut flush with the walls. As seen in Figure 50 from B-1024 the walls are 1 foot thick, making the remaining penetration 1 foot in length. The calculated surface areas and void space volumes are shown in Attachment K.

Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space Category, End Sum of Length Sum of Int SA Sum of Void Space State meters m2 m3 Bld to Yard Pen 2.44 0.89 0.03 Pipe in Pen 2.44 0.89 0.03 Grand Total 2.44 0.89 0.03 Page 69 of 123

TSD 14-016 Revision 0 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005 Page 70 of 123

TSD 14-016 Revision 0 Figure 50 - Top View Approximate Penetration Locations B-1024 4.5. Buried Piping Inventory The buried piping associated with the end state structures, such as the service water lines that run under the Main Steam Tunnel slabs, the Condensate, Service Water Supply Headers and Primary Water lines exiting the Turbine Building slab near match line A, Circulating Water Discharge Ice Melting lines, etc. have had the determination of their lengths, surface areas, and void space volumes described in the previous sections. The inventory of buried pipe is provided in Attachment K. The calculated pipe lengths, surface areas and void space volume are summarized in Table 59.

Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces Category, End Sum of Length Sum of Int SA Sum of Void Space State meters m2 m3 Bld to Bld Pen 302.51 894.48 585.08 Buried Pipe 302.51 894.48 585.08 Bld to Yard Pen 1082.95 1047.50 173.29 Buried Pipe 1082.95 1047.50 173.29 Grand Total 1385.46 1941.98 758.37 4.6. Fuel Handling Building The fuel handling building penetrations are described in the Auxiliary Building and Containment calculation sections. The inventory of piping and penetrations affiliated with the Fuel Handling Page 71 of 123

TSD 14-016 Revision 0 Building are provided in Attachment M. The lengths, surface areas and void spaces are summarized in Table 60.

Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces Category, End Sum of Length Sum of Int SA Sum of Void Space State meters m2 m3 Bld to Bld Pen 38.56 13.34 1.34 Buried Pipe 33.56 4.31 0.04 Pipe in Sleeve 5.00 9.03 1.30 Bld to Yard Pen 797.07 324.12 20.89 Buried Pipe 797.07 324.12 20.89 Grand Total 835.63 337.46 22.23

5. CONCLUSION The complete inventory of end state penetrations and piping along with the estimated lengths, surface areas and void spaces is provided in Attachment F. Attachments A through E provide the overall layout and location of these penetrations. Attachments G through P provide the inventory associated with each piping group. The piping group lengths, surface reas and void space volumes are summarized in Table 61.

Page 72 of 123

TSD 14-016 Revision 0 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes Embedded Bld to Bld Pen Bld to Yard Pen Total Void Surface Void Surface Void Void Length Surface Volume Length Area Volume Length Area Volume Length Surface Volume 2 3 2 3 2 3 2 3 LTP Pipe Group TSD Location m Area m m m m m m m m m Area m m U1 CTMT PEN Attachment G 169.20 242.36 32.48 169.20 242.36 32.48 U2 CTMT PEN Attachment G 169.20 242.36 32.48 169.20 242.36 32.48 U1 Incore Embedded Pipe Attachment G 8.15 1.05 0.015 8.15 1.05 0.01 U2 Incore Embedded Pipe Attachment G 8.15 1.05 0.015 8.15 1.05 0.01 U1 MS Drains Embedded Pipe Attachment H 145.93 46.88 1.20 145.93 46.88 1.20 U2 MS Drains Embedded Pipe Attachment H 144.41 46.39 1.19 144.41 46.39 1.19 U1 Tendon Tunnel Embedded Pipe Attachment H 160.02 51.41 1.31 160.02 51.41 1.31 U2 Tendon Tunnel Embedded Pipe Attachment H 160.02 51.41 1.31 160.02 51.41 1.31 Auxiliary Building PEN Attachment I 482.89 585.06 72.34 924.37 363.69 161.87 1407.26 948.75 234.21 Turbine Building PEN Attachment J 291.56 354.61 43.79 235.59 726.53 13.46 527.15 1081.14 57.24 TB Embedded Pipe Attachment J 588.26 302.43 13.13 588.26 302.43 13.13 WWTF PEN Attachment K 2.44 0.89 0.03 2.44 0.89 0.03 Crib House PEN Attachment L 10.97 1.14 2.92 10.97 1.14 2.92 Spent Fuel PEN Attachment M 38.56 13.34 1.34 797.07 324.12 20.89 835.63 337.46 22.23 Buried Pipe Attachment N 302.51 894.48 585.08 1082.95 1047.50 173.29 1385.46 1941.98 758.37 Circ Water Intake Attachment O 384.27 4412.09 4393.19 384.27 4412.09 4393.19 Circ Water Discharge Pipe Attachment P 202.40 1074.86 666.09 202.40 1074.86 666.09 Page 73 of 123

TSD 14-016 Revision 0

6. REFERENCES
1. TSD 13-005 Unit 1 & 2 Reactor Building Estimated End State Concrete and Liner Volumes and Surface Areas.
2. TSD 13-006 Reactor Building Units 1 and 2 End State Concrete and Liner Initial Characterization Source Terms and Distributions.
3. TSD 14-005, Backfill Material Specifications.
4. Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016.
5. TSD 14-015, Buried Pipe Dose Modeling & DCGLs, Revision 1, March 2016.
6. FSS Plan 06105B Turbine Building Imbedded Piping.
7. ComEd Zion Station Historical Site Assessment, Version 1 - August, 1999.
8. 10 CFR 20 Standards for Protection Against Radiation, Subpart ERadiological Criteria for License Termination http://www.nrc.gov/reading-rm/doc-collections/cfr/part020/.
9. 10 CFR 61.55 Waste Classification.
10. TSD 14-019 Radionuclides of Concern for Soil and Basement Fill Model Source Terms.
11. M-5 Zion Station Unit 1 and 2 General Arrangement Plan Ground Floor 592.
12. TSD 14-014, Rev 2. End State Surface Areas, Volumes, and Source Terms of Ancillary Buildings, August 2015.

Page 74 of 123

TSD 14-016 Revision 0

7. ATTACHMENTS 7.1. Attachment A - Building Penetrations South 7.2. Attachment B - Building Penetrations North 7.3. Attachment C - Building Penetrations East 7.4. Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains 7.5. Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains 7.6. Attachment F - End State Penetration and Piping Inventory 7.7. Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 7.8. Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory 7.9. Attachment I - Auxiliary Building Affiliated Penetrations and Piping 7.10. Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 7.11. Attachment K - Waste Water Treatment Facility 7.12. Attachment L - Crib House Penetrations and Piping 7.13. Attachment M - Fuel Handling Building Affiliated Penetrations, Piping 7.14. Attachment N - Buried Pipe Penetrations and Piping Inventory 7.15. Attachment O - Circulating Water Intake Penetrations and Piping 7.16. Attachment P - Circulating Water Discharge Piping Inventory Page 75 of 123

Attachment A TSD # 10-XXX Building Penetrations South Revision 00 Page 76 of 123

Attachment B TSD # 10-XXX Building Penetrations North Revision 00 Page 77 of 123

Attachment C TSD # 14-016 Building Penetrations East Revision 00 Page 78 of 123

Attachment D TSD # 14-016 Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 79 of 123

Attachment D TSD # 14-016 Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 80 of 123

Attachment E TSD # 14-016 Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 81 of 123

Attachment E TSD # 14-016 Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations Revision 00 Page 82 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 3.00 G 16 586.00 586.00 17.77 9.42 0.91 1.65 0.27 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 3.00 G 16 578.25 578.25 3.16 0.33 0.91 0.29 0.01 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 3.00 G 16 586.00 586.00 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 3.00 G 23 586.00 586.00 17.77 9.42 0.91 1.65 0.27 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 3.00 G 23 588.00 588.00 3.16 0.33 0.91 0.29 0.01 Main A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Stm Aux Fire Protection 10.75 0.365 10.02 3.00 H 10 571.00 571.00 7.87 1.89 0.91 0.73 0.05 Aux Bld Vents &

A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Drains 4.5 0.237 4.026 3.00 G 13 569.75 569.75 3.16 0.33 0.91 0.29 0.01 Aux Bld Vents &

A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Drains 4.5 0.237 4.026 3.00 G 13 568.75 568.75 3.16 0.33 0.91 0.29 0.01 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 3.00 G 13 573.25 573.25 2.41 0.20 0.91 0.22 0.01 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 3.00 G 14 572.25 572.25 7.87 1.89 0.91 0.73 0.05 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 3.00 G 17 574.50 574.50 1.62 0.09 0.91 0.15 0.00 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 3.00 G 17 565.50 565.50 2.41 0.20 0.91 0.22 0.01 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 3.00 G 17 573.17 573.17 3.16 0.33 0.91 0.29 0.01 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 3.00 G 17 570.50 570.50 14.77 6.54 0.91 1.37 0.19 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 3.00 G 13 571.00 571.00 4.76 0.72 0.91 0.44 0.02 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 2.00 H 10 571.00 571.00 6.87 2.14 0.61 0.64 0.06 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 3.00 G 23 586.50 586.50 7.87 1.89 0.91 0.73 0.05 Main A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Stm Aux Fire Protection 10.75 0.365 10.02 3.00 H 30 571.00 571.00 7.87 1.89 0.91 0.73 0.05 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 3.00 G 17 573.42 573.42 2.41 0.20 0.91 0.22 0.01 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 3.00 G 24 576.25 576.25 2.41 0.20 0.91 0.22 0.01 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 3.00 G 24 568.75 568.75 2.41 0.20 0.91 0.22 0.01 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 3.00 G 24 568.75 568.75 3.16 0.33 0.91 0.29 0.01 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 3.00 G 24 573.00 573.00 4.76 0.72 0.91 0.44 0.02 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 3.00 G 24 571.00 571.00 13.25 5.30 0.91 1.23 0.15 Service Water Supply A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Header 36 0.75 34.5 3.00 G 23 575.00 575.00 27.10 21.21 0.91 2.52 0.60 Service Water Supply to Service Water to DG Diesel Generator Heat A027 M-102, M-168. M-185 OSW-008-12" Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 74.50 G 10 554.75 567.50 232.84 57.91 22.71 21.63 1.64 Service Water to DG Service Water to DG A028 M-102, M-168. M-185 OSW-008-12" Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Hxs 12.75 0.406 11.938 77.67 G 10 553.33 567.50 242.75 60.37 23.67 22.55 1.71 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pool - Spent Fuel Pool -

A029 197, M-106 Sect K-K 1SF-017-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 89.58 R 24 570.58 583.33 48.48 2.09 27.31 4.50 0.06 Service Water Supply to Diesel Generator Heat A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 74.50 G 30 554.75 567.50 232.84 57.91 22.71 21.63 1.64 Service Water Supply to Diesel Generator Heat A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 77.67 G 30 553.33 567.50 242.75 60.37 23.67 22.55 1.71 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 2.00 H 30 571.00 571.00 6.87 1.88 0.61 0.64 0.05 M-107 Sh 1, 2 ,3 , M-A036 197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 24 570.00 0.00 415.27 195.73 21.37 38.58 5.54 Page 83 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A037 197, M-106 Sect K-K 1AD-149-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571.00 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A038 197, M-106 Sect K-K 1AD-148-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571.00 Unknown 11.68 0.39 8.44 1.08 0.01 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A039 197, M-106 Sect K-K 1AD-147-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 24 571.00 Unknown 7.48 0.25 5.41 0.70 0.01 M-107 Sh 1, 2 ,3 , M-A040 197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R 24 569.33 584.00 131.25 11.01 37.96 12.19 0.31 M-107 Sh 1, 2 ,3 , M-A041 197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R 24 569.33 583.00 39.69 1.33 28.70 3.69 0.04 M-107 Sh 1, 2 ,3 , M-A042 197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R 24 570.58 484.00 34.39 1.48 19.37 3.19 0.04 M-107 Sh 1, 2 ,3 , M-A043 197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R 24 570.58 584.00 96.00 8.05 27.76 8.92 0.23 M-107 Sh 1, 2 ,3 , M-A044 197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R 24 570.58 584.00 50.10 2.16 28.22 4.65 0.06 M-107 Sh 1, 2 ,3 , M-A046 197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94.00 R 24 570.58 584.00 39.62 1.33 28.65 3.68 0.04 M-107 Sh 1, 2 ,3 , M-A047 197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R 24 569.33 583.00 67.80 4.33 25.73 6.30 0.12 M-107 Sh 1, 2 ,3 , M-A048 197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86.00 R 24 569.33 583.00 46.54 2.00 26.21 4.32 0.06 M-107 Sh 1, 2 ,3 , M-A049 197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R 24 570.58 584.00 335.99 70.14 39.04 31.21 1.99 M-107 Sh 1, 2 ,3 , M-A050 197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R 24 570.58 584.00 343.42 71.69 39.90 31.91 2.03 M-107 Sh 1, 2 ,3 , M-A051 260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 16 570.00 573.00 415.27 195.73 21.37 38.58 5.54 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A052 260, M-106 Sect K-K 2AD-149-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571.00 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A053 260, M-106 Sect K-K 2AD-148-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571.00 Unknown 11.68 0.39 8.44 1.08 0.01 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell A054 260, M-106 Sect K-K 2AD-147-1 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 16 571.00 Unknown 7.48 0.25 5.41 0.70 0.01 M-107 Sh 1, 2 ,3 , M-A055 260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R 16 569.33 583.00 61.28 2.64 34.52 5.69 0.07 M-107 Sh 1, 2 ,3 , M-A056 260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111.00 R 16 569.33 583.00 89.16 5.70 33.83 8.28 0.16 M-107 Sh 1, 2 ,3 , M-A057 260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.50 R 16 569.33 583.00 87.95 5.62 33.38 8.17 0.16 M-107 Sh 1, 2 ,3 , M- Decon Pad Drain to A058 260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Chem Drain Tank 2.375 0.154 2.067 89.75 R 16 569.33 583.00 48.57 2.09 27.36 4.51 0.06 M-107 Sh 1, 2 ,3 , M-A059 260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R 16 570.58 584.00 284.84 59.46 33.10 26.46 1.68 M-107 Sh 1, 2 ,3 , M-A060 260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R 16 570.58 584.00 279.16 58.27 32.44 25.93 1.65 M-107 Sh 1, 2 ,3 , M-A061 260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R 16 569.33 583.00 103.01 6.58 39.09 9.57 0.19 M-107 Sh 1, 2 ,3 , M-A062 197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R 16 570.58 584.00 136.67 11.46 39.52 12.70 0.32 M-107 Sh 1, 2 ,3 , M-A063 260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R 16 570.58 583.00 101.74 6.50 38.61 9.45 0.18 M-107 Sh 1, 2 ,3 , M-A064 260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R 16 570.58 584.00 79.94 4.11 37.69 7.43 0.12 M-107 Sh 1, 2 ,3 , M-A065 260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R 16 569.33 584.00 100.13 6.40 38.00 9.30 0.18 M-107 Sh 1, 2 ,3 , M-A066 260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.50 R 16 569.33 583.00 52.48 1.76 37.95 4.88 0.05 Fire Line Below to C001 M-105 SH 1 & 2, M-271 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard ForeBay 0 10.75 0.365 10.02 4.00 AA 111.00 581.75 581.75 0.87 2.19 1.22 0.08 0.06 C002 M-106, M-272 OSA-002-3" Station Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Station Air 6 3.5 0.216 3.068 4.00 AA 111.00 581.00 581.00 0.52 0.79 1.22 0.05 0.02 C003 M-106, M-272 0 Control Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Control Air 6 2.375 0.154 2.067 4.00 AA 111.00 581.00 581.00 0.52 0.79 1.22 0.05 0.02 Page 84 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 C004 M-106, M-272 OHS-020-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Supply 6 3.5 0.216 3.068 4.00 AA 111.00 581.50 581.50 0.52 0.79 1.22 0.05 0.02 C005 M-106, M-272 OHS-024-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Return 6 2.375 0.154 2.067 4.00 AA 111.00 581.50 581.50 0.52 0.79 1.22 0.05 0.02 C006 M-106, M-272 OMU-031-3" Filtered Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Filtered Water 0 3.5 0.216 3.068 4.00 AA 111.00 581.50 581.50 0.27 0.21 1.22 0.02 0.01 Fire Line Below to C007 M-106, M-272 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard ForeBay 0 10.75 0.365 10.02 4.00 AA 111.00 585.75 585.75 0.87 2.19 1.22 0.08 0.06 Service Water Supply M-104 & M-105 sh 1, Service Water Supply Header Aux Pen to C026 M-102, M-168 OSW-014-48" Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Under TB 48 0.625 46.75 171.50 G 19 549.67 549.67 174.92 2044.35 52.27 16.25 57.89 M-104 & M-105 sh 1, Service Water Supply C026c M-102, M-168 OSW-014-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Header Crib Pen 0 48 0.625 46.75 4.00 AA 19.00 579.00 579.00 4.08 47.68 1.22 0.38 1.35 Service Water Supply Service Water Supply Header at TB C026a M-105 SH 1 & 2, M-272 OSW-014-48" Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 19 579.00 549.67 38.08 445.03 11.38 3.54 12.60 Service Water Supply M-104 & M-105 sh 1, Service Water Supply Header Aux Pen to C029 M-102, M-168 OSW-013-48" Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Under TB 48 0.625 46.75 171.50 G 21 549.67 549.67 174.92 2044.35 52.27 16.25 57.89 M-104 & M-105 sh 1, Service Water Supply C029c M-102, M-168 OSW-013-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Header Crib Pen 0 48 0.625 46.75 4.00 AA 21.00 579.00 579.00 4.08 47.68 1.22 0.38 1.35 Service Water Supply Service Water Supply Header at TB C029a M-105 SH 1 & 2, M-272 OSW-013-48" Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 21 579.00 549.67 38.08 445.03 11.38 3.54 12.60 U1 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.07 U1 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 6 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.03 U1 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 6 0 0 0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.03 U1 Boron Injection Tank to P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 8 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.05 Main U1 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U1 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U1 P007 M-281, M-661 1-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U1 P008 M-281, M-661 1-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U1 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Main U1 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Main U1 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Main U1 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.63 Reactor Coolant No. 1 Residual Heat U1 Loop to Residual Heat P017 M-281, M-661 1-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.59 U1 Cavity Fill Pump 1A P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 Component Cooling U1 Water Supply Header to P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U1 Cavity Fill Pump 1B P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U1 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 28 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.59 Residual Heat Residula Heat U1 Exchanger to RC Loop P022 M-281, M-661 1-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.59 U1 RC Pumps to Comp P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.11 Page 85 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U1 Safety Inj Pumps to RC P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.15 U1 RC Pumps to Comp P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.11 U1 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.11 B-278, M-7, B-223, M- U1 Recirculating Sump P035 170, 1SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.80 B-278, M-7, B-223, M- U1 Cavity Flood Sump P036 170, 1CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.77 B-278, M-7, B-223, M- U1 Cavity Flood Sump P037 170, 1CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.78 CTMT Sump Pump U1 Dischage to Aux Bld Flr P042 M-281, M-661 1-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Drain Analysis Tank 6 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.03 RC Drain Pump U1 Discharge to Hold-Up P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Tank 8 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.05 M-281, B-213 Detail 4, U1 P049 M-661 0 Cavity Bld to Bld Pen Pipe in Sleeve Class 1 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.65 U1 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.07 Containment U1 P054 M-281, M-661 1-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Containment Pressure 6 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.03 U1 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Filtered Vents 8 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.05 U1 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.07 1-VC-033,043, U1 RC Pump Seal Water P066 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Supply Lines 14 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.15 U1 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 18 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U1 Aux Feedwater to Steam P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 U1 Aux Feedwater to Steam P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.15 Refueling Cavity Drain U1 to Purification Pump P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 U1 Steam Generator P071 M-281, M-661 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.15 U1 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 18 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U1 Aux Feedwater to Steam P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.15 U1 Accumulator Tank P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.15 U1 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Non-Filtered Vents 8 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.05 U1 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.07 U1 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.07 U1 Press Stem, Press Liq, P086 M-282, M-661 1-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.07 U1 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.07 U1 Heating System Hot P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U1 Heating System Hot P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U1 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 28 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.59 Page 86 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Main U1 Blowdown Steam P091 M-281, M-661 1-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown Steam P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown Steam P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown Steam P094 M-281, M-661 1-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown Steam P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U1 Blowdown Steam P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U1 Blowdown Steam P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U1 Blowdown Steam P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 U1 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 8 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.05 U1 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.43 Residual Heat Residula Heat U1 Exchanger to RC Loop P105 M-282, M-662 1-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.24 Main U1 Steam Generator P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U1 Steam Generator P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown (Steam P115 M-282, M-662 1-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown (Steam P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown (Steam P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U1 Blowdown (Steam P118 M-282, M-662 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 B-278, M-7, B-223, M- U1 Recirculating Sump P123 170, 1SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.84 B-278, M-7, B-223, M- U1 Recirculating Sump P124 170, 1SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.89 Embedded U1 U1 P125 B-234 1AD-??-??? Drain Bld Pen Pipe Class 1 CTMT CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.74 0 0 542.50 542.50 11.27 0.53 8.15 1.05 0.01 Main U1 Steam to Aux FW P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U1 Steam to Aux FW P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 U2 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.07 U2 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 6 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.03 U2 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 6 0 0 0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.03 U2 Boron Injection Tank to P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 8 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.05 Main U2 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U2 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U2 P207 M-281, M-661 2-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U2 P208 M-281, M-661 2-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 Main U2 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Page 87 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Main U2 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Main U2 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.63 Main U2 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.63 Reactor Coolant No. 1 Residula Heat U2 Loop to Residual Heat P217 M-281, M-661 2-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.59 U2 Cavity Fill Pump 1A P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 Component Cooling U2 Water Supply Header to P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U2 Cavity Fill Pump 1B P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U2 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 28 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.59 Residual Heat Residula Heat U2 Exchanger to RC Loop P222 M-281, M-661 2-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.59 U2 RC Pumps to Comp P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U2 Safety Inj Pumps to RC P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.15 U2 RC Pumps to Comp P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.11 U2 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.11 B-278, M-7, B-223, M- U2 Recirculating Sump P235 170, 2SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.80 B-278, M-7, B-223, M- U2 Cavity Flood Sump P236 170, 2CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.77 B-278, M-7, B-223, M- U2 Cavity Flood Sump P237 170, 2CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.78 CTMT Sump Pump U2 Dischage to Aux Bld Flr P242 M-281, M-661 2-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Drain Analysis Tank 6 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.03 RC Drain Pump U2 Discharge to Hold-Up P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Tank 8 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.05 M-281, B-213 Detail 4, U2 P249 M-661 0 Cavity Bld to Bld Pen Pipe in Sleeve Class 1 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.65 U2 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.07 Containment U2 P254 M-281, M-661 2-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Containment Pressure 6 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.03 U2 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Filtered Vents 8 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.05 U2 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.07 2-VC-033,043, U2 RC Pump Seal Water P266 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Supply Lines 14 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.15 U2 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 18 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U2 Aux Feedwater to Steam P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 U2 Aux Feedwater to Steam P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.15 Refueling Cavity Drain U2 to Purification Pump P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 U2 Steam Generator P271 M-281, M-661 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.15 Page 88 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U2 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 18 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 U2 Aux Feedwater to Steam P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.15 U2 Accumulator Tank P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.15 U2 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Non-Filtered Vents 8 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.05 U2 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.07 U2 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.07 U2 Press Stem, Press Liq, P286 M-282, M-661 2-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.07 U2 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.07 U2 Heating System Hot P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U2 Heating System Hot P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.11 U2 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 28 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.59 Main U2 Blowdown Steam P291 M-281, M-661 2-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown Steam P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown Steam P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown Steam P294 M-281, M-661 2-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown Steam P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U2 Blowdown Steam P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U2 Blowdown Steam P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 Main U2 Blowdown Steam P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 U2 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 8 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.05 U2 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.43 Residual Heat Residula Heat U2 Exchanger to RC Loop P305 M-282, M-662 2-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.24 Main U2 Steam Generator P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U2 Steam Generator P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown (Steam P315 M-282, M-662 2-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown (Steam P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown (Steam P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 Main U2 Blowdown (Steam P318 M-282, M-662 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 B-278, M-7, B-223, M- U2 Recirculating Sump P323 170, 2SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.84 B-278, M-7, B-223, M- U2 Recirculating Sump P324 170, 2SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 CTMT Aux Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.89 Embedded U2 U2 P325 B-234 2AD-??-??? Drain Bld Pen Pipe Class 1 CTMT CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.74 0 0 542.50 542.50 11.27 0.53 8.15 1.05 0.01 Page 89 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Main U2 Steam to Aux FW P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Main U2 Steam to Aux FW P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 Service Water Return from Diesel Generator T032 M-103 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Heat Exchangers 16 0.5 15 183.47 G 31 553.83 567.50 720.48 225.15 55.92 66.93 6.38 Service Water Return from to Diesel Generator Heat T033 M-104 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Exchangers 16 0.5 15 183.75 G 10 553.83 567.50 721.58 225.50 56.01 67.04 6.39 Main T034a M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Stm Blank Sleeve 14 0 14 2.00 H 31 587.75 587.75 7.33 2.14 0.61 0.68 0.06 Main T034b M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Stm Blank Sleeve 14 0 14 2.00 H 10 587.75 587.75 7.33 2.14 0.61 0.68 0.06 T035 M-106, M-107 0 Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 3.00 J 5 583.50 584.50 7.87 1.64 0.91 0.73 0.05 T036 M-106, M-107 0 Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 3.00 J 35 583.50 584.50 7.87 1.64 0.91 0.73 0.05 Diesel Oil Tank Fill Line length to 588' T068 M-104, M-562 2DO-006-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG Yard elevation 4.5 0.237 4.026 4.00 G 5 585.25 593.00 4.22 0.35 1.22 0.39 0.01 T069 M-104, M-562, M-663 2DO-004-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 1.50 G 6 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T070 M-104, M-562, M-663 2DO-001-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 1.50 G 7 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T070a M-104 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG TB Open Sleeve 8 0 0 1.50 G 8 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T071 M-103, M-214, M-244 1DO-010-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 1.50 G 32 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T072 M-103, M-214, M-244 1DO-003-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 1.50 G 33 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T073 M-103, M-214, M-244 1DO-002-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 1.50 G 34 585.17 585.17 3.14 0.52 0.46 0.29 0.01 Diesel Oil see buried T074 M-103, M-214 1DO-001-4" Diesel Oil Bld to Yard Pen Buried Pipe Class 3 DG Yard pipe 4.5 0.237 4.026 52.25 G 35 585.25 593.00 55.07 4.62 15.93 5.12 0.13 U2 Embedded Disch T075 M-104, B-68, B-100 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Unit 2 Stand Pipe 48 0.625 46.75 38.60 F 9 588.00 553.00 472.45 460.15 11.77 43.89 13.03 U1 Embedded Disch T076 M-103, B-62, B-100 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Unit 1 Stand Pipe 48 0.625 46.75 38.60 F 31 588.00 553.00 472.45 460.15 11.77 43.89 13.03 Unit 2 Circulating U2 Water Discharge from M-15, M-101, B-100, M- Embedded Disch Condenser to Discharge T077 104 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 145.5 0.75 144 5.00 E 9 562.00 557.00 188.50 565.49 1.52 17.51 16.01 Unit 2 Circulating U2 Water Discharge from M-15, M-101, B-100, M- Embedded Disch Condenser to Discharge T078 104 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 145.5 0.75 144 5.00 E 9 562.00 557.00 188.50 565.49 1.52 17.51 16.01 U2 Unit 2 Service Water Embedded Disch Return to Discharge T079 B-66, B-68, M-104 0 Service Water Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 48 0.625 46.75 199.92 E 9 553.83 560.00 2446.80 2383.09 60.93 227.32 67.48 Unit 1 Circulating U1 Water Discharge from Embedded Disch Condenser to Discharge T080 M-780, M-101, M-103 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 145.5 0.75 144 5.00 E 31 562.00 557.00 188.50 565.49 1.52 17.51 16.01 Unit 1 Circulating U1 Water Discharge from Embedded Disch Condenser to Discharge T081 M-780, M-101, M-103 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 145.5 0.75 144 5.00 E 31 562.00 557.00 188.50 565.49 1.52 17.51 16.01 U1 Unit 1 Service Water Embedded Disch Return to Discharge T082 B-62, B-64, M-103 0 Service Water Bld to Bld Pen Pipe Class 3 TB Tun Tunnel 48 0.625 46.75 199.92 E 33 553.83 560.00 2446.80 2383.09 60.93 227.32 67.48 Unit 2 Blind Flange M-780, M-100, M-101, Embedded Man Entry to Circ T083 M-104 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9.00 D 6 564.00 564.00 83.06 60.99 2.74 7.72 1.73 Page 90 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U2 M-780, B-68, B-100, B- Embedded Disch Unit 2 Circ Water T084 68, M-104 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Discharge Stand Pipe 36 0.375 35.25 29.50 D 9 588.00 558.50 272.24 199.93 8.99 25.29 5.66 Unit 2 Blind Flange M-780, M-100, M-101, Embedded Man Entry to Circ T085 M-104 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9.00 D 13 564.00 564.00 83.06 60.99 2.74 7.72 1.73 U1 Embedded Disch Unit 1 Circ Water T086 M-15, B-62, B-100, B-66 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Discharge Stand Pipe 36 0.375 35.25 29.50 D 31 588.00 558.50 272.24 199.93 8.99 25.29 5.66 Unit 1 Blind Flange M-15, M-100, M-101, B- Embedded Man Enttry to Circ T087 64, M-103 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9.00 D 27 564.00 564.00 83.06 60.99 2.74 7.72 1.73 Unit 1 Blind Flange M-15, M-100, M-101, B- Embedded Man Enttry to Circ T088 62, M-103 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9.00 D 34 564.00 564.00 83.06 60.99 2.74 7.72 1.73 Spares Blanks Left T091 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Intact 10.75 0.365 10.02 5.00 C 16 585.00 585.00 13.12 2.74 1.52 1.22 0.08 Spares Blanks Left T092 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Intact 12.75 0.406 11.938 5.00 C 16 586.00 586.00 15.63 3.89 1.52 1.45 0.11 Spares Blanks Left T093 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Intact 14 0.438 13.124 5.00 C 16 585.00 585.00 17.18 4.70 1.52 1.60 0.13 Fibercast Makeup T094 M-104 0 Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Demin Waste Discharge 8.625 0.322 7.981 4.00 C 17 586.00 586.00 8.36 1.39 1.22 0.78 0.04 Primary Water Storage T095 M-104, M-105 0 Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Tank 6.625 0.28 6.065 118.33 C 18 556.75 556.75 187.89 23.74 36.07 17.46 0.67 T096 M-103 0 Oil Seperator Bld to Yard Pen Pipe in Pen Class 3 TB Yard Oil Seperator Tank 10.75 0.365 10.02 4.00 C 23 586.00 586.00 10.49 2.19 1.22 0.97 0.06 Fibercast Makeup T097 M-103 0 Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Demin Waste Discharge 8.625 0.322 7.981 4.00 C 23 586.00 586.00 8.36 1.39 1.22 0.78 0.04 Waste Discharge (WD) from Lake Discharge Tank to Discharge T098 M-103 0 Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Tunnel 6.625 0.28 6.065 4.00 C 24 586.00 586.00 6.35 0.80 1.22 0.59 0.02 T099 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 10.75 0.365 10.02 5.00 C 24 585.00 585.00 13.12 2.74 1.52 1.22 0.08 T100 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 12.75 0.406 11.938 5.00 C 24 586.00 586.00 15.63 3.89 1.52 1.45 0.11 T101 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 14 0.438 13.124 5.00 C 24 585.00 585.00 17.18 4.70 1.52 1.60 0.13 Primary Water Supply T102 M-104, M-105 0 Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Header to RCP 6.625 0.28 6.065 78.33 C 17 586.00 586.00 124.38 15.72 23.88 11.56 0.45 Condensate to Alternate M-105 SH 1 & SH 2, M- Feedwater Pumps-T103 103 0 Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Buried Section 20 0.594 18.812 226.05 B 21 586.00 586.00 1020.52 367.34 68.90 94.81 10.40 T104 M-104 0 Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Lake Discharge tank 6.625 0.28 6.065 4.00 C 17 586.00 586.00 6.35 0.80 1.22 0.59 0.02 Condensate Pump T105 M-103 0 Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Recirc 4.5 0.337 3.826 221.05 G 22 560.00 586.00 6219.50 14.99 67.38 577.81 0.42 To condensate transfer T106 M-103 0 Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard and makeup pumps 12.75 0.406 11.938 20.93 D 22 560.00 583.25 65.41 16.27 6.38 6.08 0.46 Embedded Unit 1 Circ water supply T109 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 34 564.00 564.00 291.38 643.47 3.20 27.07 18.22 Embedded Unit 1 Circ water supply T110 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 34 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded T111 M-100, B-61 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 45.63 E 34 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 T111b M-100, B-61 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 22.50 E 34 564.00 564.00 833.50 2457.10 6.86 77.44 69.58 Embedded T112 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 124.20 E 34 564.00 564.00 4600.94 13563.19 37.86 427.44 384.07 Embedded Unit 1 Circ water pipe T113 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib 12' to 17' expansion 174 1.5 171 9.00 E 34 558.00 558.00 402.91 1435.36 2.74 37.43 40.64 T114 M-100 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 204 1.5 201 94.67 B 31 558.00 558.00 4981.52 20860.11 28.85 462.80 590.69 T115 M-100, M-272 1CW-001-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 14.25 AA 20 558.00 558.00 499.12 1434.84 4.34 46.37 40.63 Page 91 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 T116 M-100, M-272 1CW-002-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 19.50 AA 22 558.00 558.00 541.14 1195.02 5.94 50.27 33.84 T117 M-100, M-272 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 14.25 AA 24 558.00 558.00 395.45 873.28 4.34 36.74 24.73 T118 M-100 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 114 1 112 8.25 AA 26 558.00 558.00 241.90 564.44 2.51 22.47 15.98 T119 M-100 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 120 1 118 14.00 AA 26 558.00 558.00 432.49 1063.21 4.27 40.18 30.11 Embedded Unit 1 Circ water supply T120 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 26 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded Unit 1 Circ water supply T121 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2,5 E 26 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded Unit 2 Circ water supply T122 M-100, B-61 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 144 1.25 141.5 45.63 E 6 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 Unit 2 Circ water supply T122b M-100, B-61 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib pipe to Condenser 144 1.25 141.5 83.50 E 6 564.00 564.00 1760.39 5089.54 25.45 163.55 144.12 Embedded Unit 2 Circ water supply T123 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 6 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded Unit 2 Circ water supply T123a M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 6 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded T124 M-100, B-61 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E 6 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 T124b M-100, B-61 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 22.50 E 6 564.00 564.00 1760.39 5089.54 6.86 163.55 144.12 Embedded Unit 2 Circ water pipe T125 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib 12' to 17' expansion 144 1.25 141.5 124.20 E 6 564.00 564.00 4600.94 13563.19 37.86 427.44 384.07 Embedded Unit 2 Circ water pipe T126 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib 12' to 17' expansion 174 1.5 171 9.00 B 8 558.00 558.00 402.91 1435.36 2.74 37.43 40.64 T127 M-100 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 204 1.5 201 94.67 A 12 558.00 558.00 4981.52 20860.11 28.85 462.80 590.69 T128 M-100, M-272 2CW-001-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 14.25 AA 20 558.00 558.00 499.12 1434.84 4.34 46.37 40.63 T129 M-100, M-272 2CW-002-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 19.50 AA 18 558.00 558.00 541.14 1195.02 5.94 50.27 33.84 T130 M-100, M-272 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 14.25 AA 16 558.00 558.00 395.45 873.28 4.34 36.74 24.73 T131 M-100 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 114 1 112 8.25 AA 14 558.00 558.00 241.90 564.44 2.51 22.47 15.98 T132 M-100 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 120 1 118 14.00 AA 14 558.00 558.00 432.49 1063.21 4.27 40.18 30.11 Embedded Unit 2 Circ water supply T133 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 14 572.00 572.00 291.38 643.47 3.20 27.07 18.22 Embedded Unit 2 Circ water supply T134 M-100 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib pipe to Condenser 108 1 106 2.50 E 14 572.00 572.00 291.38 643.47 3.20 27.07 18.22 U2 Embedded Disch Unit 2 Hatch to T135 M-104, B-68, B-100 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Discharge Tunnel 36 0.375 35.25 4.00 D 9 562.00 562.00 36.91 27.11 1.22 3.43 0.77 U1 Embedded Disch Unit 1 Hatch to T136 M-103, B-62, B-100 0 Circ Water Discharge Bld to Bld Pen Pipe Class 3 TB Tun Discharge Tunnel 36 0.375 35.25 4.00 D 31 562.00 562.00 36.91 27.11 1.22 3.43 0.77 U2 Disch Unit 2 Circ Water T137 M-1, M-2, B-39, M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Lake Discharge Pipe to Lake 168 0.75 166.5 50.00 GG 9 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 U1 Disch Unit 1 Circ Water T138 M-1, M-2, B-39, M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Lake Discharge Pipe to Lake 168 0.75 166.5 50.00 GG 31 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 U2 Disch Unit 2 Circ Water Ice T139 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Melting Pipe 144 1.25 141.5 80.42 GG 31 569.00 569.00 2978.98 8781.78 24.51 276.76 248.67 U2 Disch Unit 2 Circ Water Ice T140 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Melting Pipe 96 1 94 25.00 GG 31 569.00 569.00 615.23 1204.82 7.62 57.16 34.12 Disch Unit 1 Circ Water Ice T141 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Melting Pipe 144 1.25 141.5 80.42 GG 31 569.00 569.00 2978.98 8781.78 24.51 276.76 248.67 Disch Unit 1 Circ Water Ice T142 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Melting Pipe 96 1 94 25.00 GG 31 569.00 569.00 615.23 1204.82 7.62 57.16 34.12 Embedded T143 M-100, B-61 0 Circ Water Intake Bld to Bld Pen Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E 14 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 Page 92 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 T143b M-100, B-61 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 83.50 E 14 564.00 564.00 1760.39 5089.54 25.45 163.55 144.12 Circ Water Intake to T144 M-2, B-49 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Forebay 192 0.75 190.5 50.00 GG 16 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 Circ Water Intake to T145 M-2, B-49 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Forebay 192 0.75 190.5 50.00 GG 20 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 Circ Water Intake to T146 M-2, B-49 0 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Forebay 192 0.75 190.5 50.00 GG 24 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 M-103 , B-454, B-452, Embedded U-1 Equip Drain Sump, T147 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 6 pipe West Wall 6 0.28 5.44 200.00 0.00 0 560.00 557.00 284.84 32.28 60.96 26.46 0.91 M-103 , B-454, B-452, Embedded U-1 Equip Drain Sump, T148 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 6 pipe North Wall 6 0.28 5.44 100.00 0.00 0 560.00 557.00 142.42 16.14 30.48 13.23 0.46 M-103 , B-454, B-452, Embedded U-2 Equip Drain Sump, T149 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 6 pipe West Wall 6 0.28 5.44 200.00 0.00 0 560.00 557.00 284.84 32.28 60.96 26.46 0.91 Floor Drain Sump, M-103 , B-454, B-452, Embedded West-most 6 pipe on T150 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB North Wall 6 0.28 5.44 100.00 0.00 0 560.00 557.00 142.42 16.14 30.48 13.23 0.46 Floor Drain Sump East-M-103 , B-454, B-452, Embedded most 4 pipe on North T151 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB Wall 4 0.237 3.526 100.00 0.00 0 560.00 557.00 92.31 6.78 30.48 8.58 0.19 M-103 , B-454, B-452, Embedded Fire Sump, South-most T152 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 4 pipe on West Wall 4 0.237 3.526 150.00 0.00 0 560.00 557.00 138.47 10.17 45.72 12.86 0.29 M-103 , B-454, B-452, Embedded Fire Sump, North-most T153 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 8 pipe on West Wall 8 0.322 7.356 450.00 0.00 0 560.00 557.00 866.61 132.81 137.16 80.51 3.76 M-103 , B-454, B-452, Embedded Fire Sump, West-most T154 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 8 pipe on North Wall 8 0.322 7.356 450.00 0.00 0 560.00 557.00 866.61 132.81 137.16 80.51 3.76 M-103 , B-454, B-452, Embedded Fire Sump, West-most T155 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 10 pipe on North Wall 10 0.365 9.27 80.00 0.00 0 560.00 557.00 194.15 37.50 24.38 18.04 1.06 M-103 , B-454, B-452, Embedded Fire Sump, East-most T156 B-471, B-473 0 Aerated Drain Bld Pen Pipe Class 3 TB TB 10 pipe on North Wall 10 0.365 9.27 100.00 0.00 0 560.00 557.00 242.69 46.87 30.48 22.55 1.33 Embedded Main Unit 1 Main Steam M001 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 45.34 U 32 569.54 569.00 47.79 4.01 13.82 4.44 0.11 Embedded Main Unit 1 Main Steam M002 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 40.67 U 34 569.96 567.25 42.86 3.60 12.40 3.98 0.10 Embedded Main Unit 1 Main Steam M003 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 93.23 R 34 569.54 569.00 98.27 8.24 28.42 9.13 0.23 Embedded Main Unit 1 Main Steam M004 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 84.11 R 34 569.54 569.00 88.66 7.44 25.64 8.24 0.21 Embedded Main Unit 1 Main Steam M005 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 34.25 G 34 569.96 566.17 36.10 3.03 10.44 3.35 0.09 Embedded Main Unit 1 Main Steam M006 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 11.72 J 34 569.54 569.00 12.35 1.04 3.57 1.15 0.03 Embedded Main Unit 1 Main Steam M007 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 67.33 J 33 569.96 566.08 70.97 5.95 20.52 6.59 0.17 Embedded Main Unit 1 Main Steam M009 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 8.96 J 32 569.54 569.00 9.45 0.79 2.73 0.88 0.02 Embedded Main Unit 1 Main Steam M010 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 45.42 J 31 569.96 568.79 47.87 4.02 13.84 4.45 0.11 Embedded Main Unit 1 Main Steam M011 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 16.96 J 30 569.54 569.00 17.87 1.50 5.17 1.66 0.04 Embedded Main Unit 1 Main Steam M012 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 30.79 J 30 569.54 569.00 32.45 2.72 9.39 3.02 0.08 Embedded Unit 1 Buttress Pit to M013 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 1 Buttress Pit to M014 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 1 Buttress Pit to M015 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 L 31 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 1 Buttress Pit to M016 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 L 28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 1 Buttress Pit to M017 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 1 Tendon Tunnel M018 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Page 93 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Embedded Unit 1 Tendon Tunnel M019 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 1 Tendon Tunnel M020 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 1 Tendon Tunnel M021 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 1 Tendon Tunnel M022 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 1 Tendon Tunnel M023 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 1 Tendon Tunnel M024 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Embedded Center Pipe 4.5 0.237 4.026 359.97 R 28 547.92 547.92 379.41 31.82 109.72 35.25 0.90 Embedded Unit 1 Clean Out In M025 B466, B467 0 U1 Aerated Drain U1 Bld Pen Pipe Class 3 TT TT Front of Sump 4.5 0.237 4.026 9.75 R 28 547.54 547.50 10.28 0.86 2.97 0.95 0.02 Embedded Main Unit 2 Main Steam M201 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 45.49 U 8 569.54 568.85 47.95 4.02 13.87 4.45 0.11 Embedded Main Unit 2 Main Steam M202 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 39.50 U 6 569.96 568.42 41.63 3.49 12.04 3.87 0.10 Embedded Main Unit 2 Main Steam M203 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 92.86 R 6 569.54 568.85 97.87 8.21 28.30 9.09 0.23 Embedded Main Unit 2 Main Steam M204 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 82.86 R 6 569.54 568.83 87.33 7.32 25.25 8.11 0.21 Embedded Main Unit 2 Main Steam M205 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 34.04 G 6 569.96 566.38 35.88 3.01 10.38 3.33 0.09 Embedded Main Unit 2 Main Steam M206 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 11.95 J 6 569.54 568.88 12.59 1.06 3.64 1.17 0.03 Embedded Main Unit 2 Main Steam M207 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 66.81 J 7 569.96 566.10 70.42 5.91 20.36 6.54 0.17 Embedded Main Unit 2 Main Steam M209 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 8.95 J 8 569.54 568.88 9.43 0.79 2.73 0.88 0.02 Embedded Main Unit 2 Main Steam M210 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 43.47 J 9 569.96 568.80 45.81 3.84 13.25 4.26 0.11 Embedded Main Unit 2 Main Steam M211 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 17.02 J 10 569.54 568.94 17.94 1.50 5.19 1.67 0.04 Embedded Main Unit 2 Main Steam M212 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 Stm TT Tunnel Aerated Drain 4.5 0.237 4.026 30.85 J 10 569.54 568.94 32.52 2.73 9.40 3.02 0.08 Embedded Unit 2 Buttress Pit to M213 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 2 Buttress Pit to M214 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 2 Buttress Pit to M215 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 L 9 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 2 Buttress Pit to M216 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 L 6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 2 Buttress Pit to M217 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Tunnel Sump 4.5 0.237 4.026 30.30 R 6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 Embedded Unit 2 Tendon Tunnel M218 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M219 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M220 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M221 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M222 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M223 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Floor Drain 4.5 0.237 4.026 0.63 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 Embedded Unit 2 Tendon Tunnel M224 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Embedded Center Pipe 4.5 0.237 4.026 359.97 R 6 547.92 547.92 379.41 31.82 109.72 35.25 0.90 Embedded Unit 2 Clean Out In M225 B481, B484 0 U2 Aerated Drain U2 Bld Pen Pipe Class 3 TT TT Front of Sump 4.5 0.237 4.026 9.75 R 6 547.54 547.50 10.28 0.86 2.97 0.95 0.02 Force Main from W001 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Turbine Fire Sump 8.625 0.322 7.981 1.00 D 2 586.67 586.67 2.09 0.35 0.30 0.19 0.01 Page 94 of 123

Attachment F TSD # 14-016 Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Heater bay roof drain W002 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF lines 6.625 0.28 6.065 1.00 D 2 585.20 585.20 1.59 0.20 0.30 0.15 0.01 Sludge Line from W003 B-1003, B-1005 Sludge Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Outdoor Drying Beds 3.5 0.216 3.068 1.00 A 6 587.00 587.00 0.80 0.05 0.30 0.07 0.001 Sludge drying bed W004 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTH WWTF filtrate 6.625 0.28 6.065 1.00 A 4 588.00 588.00 1.59 0.20 0.30 0.15 0.01 W005 B-1003, B-1005 Water Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Water Line from Yard 2.375 0.154 2.067 1.00 A 3 588.00 588.00 0.54 0.02 0.30 0.05 0.001 Cement Wrapped W006 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Ductile Pipe 8.625 0.322 7.981 1.00 A 2 586.75 586.75 2.09 0.35 0.30 0.19 0.01 W007 B-1003, B-1005 Sanitary Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sanitary Line 1.9 0.145 1.61 1.00 A 2 587.00 587.00 0.42 0.01 0.30 0.04 0.0004 W008 B-1003, B-1005 Service Air Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Service Air Line 1.9 0.145 1.61 1.00 A 2 586.75 586.75 0.42 0.01 0.30 0.04 0.0004 Page 95 of 123

Attachment G TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.5 577.5 12.65 2.64 1.47 1.18 0.075 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6 0 0 0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Boron Injection Tank to Cold Legs 8 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 1-MS-003-35 P007 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 1-MS-004-35 P008 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 Residual Heat Reactor Coolant No. 1 Loop to P017 M-281, M-661 1-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 Component Cooling Water Supply P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 Residula Heat Residual Heat Exchanger to RC Loop P022 M-281, M-661 1-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 RC Pumps to Comp Cooling Pump P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 Safety Inj Pumps to RC Loop Hot P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 RC Pumps to Comp Cooling Pump P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 B-278, M-7, B- Pipe in P035 223, M-170, 1SI-008-20" Drain Bld to Bld Pen Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 B-278, M-7, B- Pipe in P036 223, M-170, 1CF-002-20" Drain Bld to Bld Pen Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 B-278, M-7, B- Pipe in P037 223, M-170, 1CF-001-20" Drain Bld to Bld Pen Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 1-WO-95-1 CTMT Sump Pump Dischage to Aux P042 M-281, M-661 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Bld Flr Drain Analysis Tank 6 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 RC Drain Pump Discharge to Hold-P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Up Tank 8 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 M-281, B-213 Pipe in P049 Detail 4, M-661 0 Cavity Bld to Bld Pen Sleeve Class 1 U1 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.649 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 Containment P054 M-281, M-661 1-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Containment Pressure 6 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Filtered Vents 8 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 1-VC-033,043, P066 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pump Seal Water Supply Lines 14 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 Page 96 of 123

Attachment G TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 Refueling Cavity Drain to Purification P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 1-BD-001-2 P071 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Non-Filtered Vents 8 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 1-SS-001,2,3- Press Stem, Press Liq, RC Hot Leg P086 M-282, M-661 3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 1-BD-007-2 P091 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-005-2 P094 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 8 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 Residula Heat Residual Heat Exchanger to RC Loop P105 M-282, M-662 1-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 1-BD-003-2 P115 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-001-2 P118 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 B-278, M-7, B- Pipe in P123 223, M-170, 1SI-007-20" Drain Bld to Bld Pen Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 B-278, M-7, B- Pipe in P124 223, M-170, 1SI-009-20" Drain Bld to Bld Pen Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Page 97 of 123

Attachment G TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void U1 Line Ident MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space Peno. Drawings No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.075 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6 0 0 0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Boron Injection Tank to Cold Legs 8 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 2-MS-003-35 P207 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 2-MS-004-35 P208 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 Residula Heat Reactor Coolant No. 1 Loop to P217 M-281, M-661 2-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 Component Cooling Water Supply P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 Residula Heat Residual Heat Exchanger to RC Loop P222 M-281, M-661 2-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 RC Pumps to Comp Cooling Pump P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 RC Pumps to Comp Cooling Pump P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 B-278, M-7, B- Pipe in P235 223, M-170, 2SI-008-20" Drain Bld to Bld Pen Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 B-278, M-7, B- Pipe in P236 223, M-170, 2CF-002-20" Drain Bld to Bld Pen Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 B-278, M-7, B- Pipe in P237 223, M-170, 2CF-001-20" Drain Bld to Bld Pen Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 2-WO-95-1 CTMT Sump Pump Dischage to Aux P242 M-281, M-661 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Bld Flr Drain Analysis Tank 6 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 RC Drain Pump Discharge to Hold-P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Up Tank 8 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 M-281, B-213 Pipe in P249 Detail 4, M-661 0 Cavity Bld to Bld Pen Sleeve Class 1 U2 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.649 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 Containment P254 M-281, M-661 2-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Containment Pressure 6 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Filtered Vents 8 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 2-VC-033,043, P266 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pump Seal Water Supply Lines 14 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 Page 98 of 123

Attachment G TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Sleeve Pipe Azimuth Azimuth Surface Space Int Void U1 Line Ident MARSSIM Size OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space Peno. Drawings No. System Category End Sate Class From To Description inches inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 Refueling Cavity Drain to Purification P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 2-BD-001-2 P271 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Non-Filtered Vents 8 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 2-SS-001,2,3- Press Stem, Press Liq, RC Hot Leg P286 M-282, M-661 3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 2-BD-007-2 P291 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-005-2 P294 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 8 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 Residula Heat Residual Heat Exchanger to RC Loop P305 M-282, M-662 2-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 2-BD-003-2 P315 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-001-2 P318 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 B-278, M-7, B- Pipe in P323 223, M-170, 2SI-007-20" Drain Bld to Bld Pen Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 B-278, M-7, B- Pipe in P324 223, M-170, 2SI-009-20" Drain Bld to Bld Pen Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Page 99 of 123

Attachment G TSD # 14-016 Unit 1 and Unit 2 Containment Penetrations and Piping List Revision 00 Incore Sump Inventory Void Sleeve Interior Space Penetration MARSSIM Size Pipe OD Wall Pipe ID Length End Surface Volume Length Int SA Void No. Drawings System Category End Sate Class From To Description inches inches Thickness inches Feet Elevation Elevation Area ft2 ft3 meters m2 Space m3 P125 B-234 Drain Bld Pen Embedded Pipe Class 1 U1 CTMT U1 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.73908 542.5 542.5 11.27 0.53 8.15 1.05 0.015 P325 B-234 Drain Bld Pen Embedded Pipe Class 1 U1 CTMT U1 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.73908 542.5 542.5 11.27 0.53 8.15 1.05 0.015 Page 100 of 123

Attachment H TSD # 14-016 Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List Revision 00 Main Steam Tunnel Drains Y or Unit X or Unit Void 1 2 Void Pipe Space Azimuth Azimuth Interior Space Int Void Pen MARSSIM OD Wall Pipe ID Length Volume Degrees - Degrees - End Surface Volume Length SA Space No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet in3 minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 M001 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.34 6925.92 U 32 569.54 569.00 47.79 4.01 13.82 4.44 0.113 M002 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 40.67 6212.37 U 34 569.96 567.25 42.86 3.60 12.40 3.98 0.102 M003 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 93.23 14242.42 R 34 569.54 569.00 98.27 8.24 28.42 9.13 0.233 M004 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 84.11 12849.55 R 34 569.54 569.00 88.66 7.44 25.64 8.24 0.211 M005 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.25 5232.14 G 34 569.96 566.17 36.10 3.03 10.44 3.35 0.086 M006 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.72 1789.66 J 34 569.54 569.00 12.35 1.04 3.57 1.15 0.029 M007 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 67.33 10286.05 J 33 569.96 566.08 70.97 5.95 20.52 6.59 0.169 M009 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.96 1369.41 J 32 569.54 569.00 9.45 0.79 2.73 0.88 0.022 M010 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.42 6938.07 J 31 569.96 568.79 47.87 4.02 13.84 4.45 0.114 M011 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 16.96 2590.61 J 30 569.54 569.00 17.87 1.50 5.17 1.66 0.042 M012 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.79 4703.83 J 30 569.54 569.00 32.45 2.72 9.39 3.02 0.077 M201 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.49 6949.51 U 8 569.54 568.85 47.95 4.02 13.87 4.45 0.114 M202 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 39.50 6034.15 U 6 569.96 568.42 41.63 3.49 12.04 3.87 0.099 M203 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 92.86 14185.06 R 6 569.54 568.85 97.87 8.21 28.30 9.09 0.232 M204 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 82.86 12657.42 R 6 569.54 568.83 87.33 7.32 25.25 8.11 0.207 M205 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.04 5200.31 G 6 569.96 566.38 35.88 3.01 10.38 3.33 0.085 M206 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.95 1824.76 J 6 569.54 568.88 12.59 1.06 3.64 1.17 0.030 M207 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 66.81 10206.49 J 7 569.96 566.10 70.42 5.91 20.36 6.54 0.167 M209 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.95 1366.75 J 8 569.54 568.88 9.43 0.79 2.73 0.88 0.022 M210 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 43.47 6639.88 J 9 569.96 568.80 45.81 3.84 13.25 4.26 0.109 M211 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 17.02 2600.16 J 10 569.54 568.94 17.94 1.50 5.19 1.67 0.043 M212 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.85 4713.38 J 10 569.54 568.94 32.52 2.73 9.40 3.02 0.077 Buttress Pit and Tendon Tunnel Drains Y or Unit X or Unit Void 1 2 Pipe Space Azimuth Azimuth Interior Void Int Pen MARSSIM OD Wall Pipe ID Length Volume Degrees - Degrees - End Surface Space Length SA Void No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet in3 minutes minutes Elevation Elevation Area ft2 Volume ft3 meters m2 Space m3 M013 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M014 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M015 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L 31 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M016 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L 28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M017 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M018 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M019 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M020 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M021 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M022 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 Page 101 of 123

Attachment H TSD # 14-016 Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List Revision 00 Y or Unit X or Unit Void 1 2 Pipe Space Azimuth Azimuth Interior Void Int Pen MARSSIM OD Wall Pipe ID Length Volume Degrees - Degrees - End Surface Space Length SA Void No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet in3 minutes minutes Elevation Elevation Area ft2 Volume ft3 meters m2 Space m3 M023 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 Unit 1 Tendon Tunnel Embedded Center M024 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Pipe 4.5 0.237 4.026 359.97 54990.79 R 28 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M025 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 1489.44 R 28 547.54 547.50 10.28 0.86 2.97 0.95 0.02 M213 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M214 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M215 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L 9 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M216 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L 6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M217 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R 6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M218 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M219 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M220 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M221 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M222 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M223 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R 6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 Unit 2 Tendon Tunnel Embedded Center M224 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Pipe 4.5 0.237 4.026 359.97 54990.79 R 6 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M225 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 1489.44 R 6 547.54 547.50 10.28 0.86 2.97 0.95 0.02 Page 102 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 3 G 16 586 586 17.77 9.42 0.91 1.65 0.267 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 3 G 16 578.25 578.25 3.16 0.33 0.91 0.29 0.009 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 3 G 16 586 586 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 3 G 23 586 586 17.77 9.42 0.91 1.65 0.267 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 3 G 23 588 588 3.16 0.33 0.91 0.29 0.009 A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3 H 10 571 571 7.87 1.89 0.91 0.73 0.054 A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 3 G 13 569.75 569.75 3.16 0.33 0.91 0.29 0.009 A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 3 G 13 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 3 G 13 573.25 573.25 2.41 0.20 0.91 0.22 0.006 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 3 G 14 572.25 572.25 7.87 1.89 0.91 0.73 0.054 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 3 G 17 574.5 574.5 1.62 0.09 0.91 0.15 0.003 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 3 G 17 565.5 565.5 2.41 0.20 0.91 0.22 0.006 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 3 G 17 573.17 573.17 3.16 0.33 0.91 0.29 0.009 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 3 G 17 570.5 570.5 14.77 6.54 0.91 1.37 0.185 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 3 G 13 571 571 4.76 0.72 0.91 0.44 0.020 See Multiple CTMT to Aux Pens on M-Main 282 and M-662 cover in CTMT A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 2 H 10 571 571 6.87 2.14 0.61 0.64 0.061 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 3 G 23 586.5 586.5 7.87 1.89 0.91 0.73 0.054 A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3 H 30 571 571 7.87 1.89 0.91 0.73 0.054 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 3 G 17 573.42 573.42 2.41 0.20 0.91 0.22 0.006 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 3 G 24 576.25 576.25 2.41 0.20 0.91 0.22 0.006 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 3 G 24 568.75 568.75 2.41 0.20 0.91 0.22 0.006 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 3 G 24 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 3 G 24 573 573 4.76 0.72 0.91 0.44 0.020 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 3 G 24 571 571 13.25 5.30 0.91 1.23 0.150 A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water Supply Header 36 0.75 34.5 3 G 23 575 575 27.10 21.21 0.91 2.52 0.600 Service Water to DG Service Water Supply to Diesel A027 M-102, M-168. M-185 OSW-008-12" Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 74.50 G 10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 Service Water to DG A028 M-102, M-168. M-185 OSW-008-12" Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 77.67 G 10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pool -

A029 197, M-106 Sect K-K 1SF-017-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool - Demin Water 2.375 0.154 2.067 89.58 R 24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 Service Water Supply to Diesel A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 74.50 G 30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 Service Water Supply to Diesel A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 77.67 G 30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 See Multiple CTMT to Aux Pens on M-Main 282 and M-662 cover in CTMT A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 2.00 H 30 571 571 6.87 1.88 0.61 0.64 0.053 M-107 Sh 1, 2 ,3 , M-A036 197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 24 570 0 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M- 1AD-149-1 Spent Fuel Pit Tell A037 197, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- 1AD-148-1 Spent Fuel Pit Tell A038 197, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M- 1AD-147-1 Spent Fuel Pit Tell A039 197, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 24 571 Unknown 7.48 0.25 5.41 0.70 0.007 Page 103 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 M-107 Sh 1, 2 ,3 , M-A040 197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R 24 569.33 584 131.25 11.01 37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M-A041 197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R 24 569.33 583 39.69 1.33 28.70 3.69 0.038 M-107 Sh 1, 2 ,3 , M-A042 197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R 24 570.58 484 34.39 1.48 19.37 3.19 0.042 M-107 Sh 1, 2 ,3 , M-A043 197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R 24 570.58 584 96.00 8.05 27.76 8.92 0.228 M-107 Sh 1, 2 ,3 , M-A044 197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R 24 570.58 584 50.10 2.16 28.22 4.65 0.061 M-107 Sh 1, 2 ,3 , M-A046 197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94.00 R 24 570.58 584 39.62 1.33 28.65 3.68 0.038 M-107 Sh 1, 2 ,3 , M-A047 197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R 24 569.33 583 67.80 4.33 25.73 6.30 0.123 M-107 Sh 1, 2 ,3 , M-A048 197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86.00 R 24 569.33 583 46.54 2.00 26.21 4.32 0.057 M-107 Sh 1, 2 ,3 , M-A049 197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R 24 570.58 584 335.99 70.14 39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M-A050 197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R 24 570.58 584 343.42 71.69 39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M-A051 260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 16 570 573 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M- 2AD-149-1 Spent Fuel Pit Tell A052 260, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- 2AD-148-1 Spent Fuel Pit Tell A053 260, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M- 2AD-147-1 Spent Fuel Pit Tell A054 260, M-106 Sect K-K 1/2" Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 16 571 Unknown 7.48 0.25 5.41 0.70 0.007 M-107 Sh 1, 2 ,3 , M-A055 260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R 16 569.33 583 61.28 2.64 34.52 5.69 0.075 M-107 Sh 1, 2 ,3 , M-A056 260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111.00 R 16 569.33 583 89.16 5.70 33.83 8.28 0.161 M-107 Sh 1, 2 ,3 , M-A057 260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.50 R 16 569.33 583 87.95 5.62 33.38 8.17 0.159 M-107 Sh 1, 2 ,3 , M-A058 260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Decon Pad Drain to Chem Drain Tank 2.375 0.154 2.067 89.75 R 16 569.33 583 48.57 2.09 27.36 4.51 0.059 M-107 Sh 1, 2 ,3 , M-A059 260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R 16 570.58 584 284.84 59.46 33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M-A060 260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R 16 570.58 584 279.16 58.27 32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M-A061 260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R 16 569.33 583 103.01 6.58 39.09 9.57 0.186 M-107 Sh 1, 2 ,3 , M-A062 197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R 16 570.58 584 136.67 11.46 39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M-A063 260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R 16 570.58 583 101.74 6.50 38.61 9.45 0.184 M-107 Sh 1, 2 ,3 , M- OWD-059-2 A064 260, M-106 Sect K-K 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R 16 570.58 584 79.94 4.11 37.69 7.43 0.116 M-107 Sh 1, 2 ,3 , M-A065 260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R 16 569.33 584 100.13 6.40 38.00 9.30 0.181 M-107 Sh 1, 2 ,3 , M-A066 260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.50 R 16 569.33 583 52.48 1.76 37.95 4.88 0.050 M-104 & M-105 sh 1, Service Water Supply Service Water Supply Header Aux Pen C026 M-102, M-168 OSW-014-48" Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard to Under TB 48 0.625 46.75 171.50 G 19 549.67 549.67 174.92 2044.35 52.27 16.25 57.889 Service Water Supply Service Water Supply Header at TB C026a M-105 SH 1 & 2, M-272 OSW-014-48" Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 19 579 549.67 38.08 445.03 11.38 3.54 12.602 M-104 & M-105 sh 1, Service Water Supply Service Water Supply Header Aux Pen C029 M-102, M-168 OSW-013-48" Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard to Under TB 48 0.625 46.75 171.50 G 21 549.67 549.67 174.92 2044.35 52.27 16.25 57.889 Service Water Supply Service Water Supply Header at TB C029a M-105 SH 1 & 2, M-272 OSW-013-48" Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 21 579 549.67 38.08 445.03 11.38 3.54 12.602 U1 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Fire Protection 4.5 0.237 4.026 4.83 107 253 577.5 577.5 12.65 2.64 1.47 1.18 0.075 U1 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 Page 104 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U1 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-15 263-45 577.5 577.5 7.59 0.95 1.47 0.71 0.027 U1 P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Boron Injection Tank to Cold Legs 3.5 0.438 2.624 4.83 94 266 577.5 577.5 10.12 1.69 1.47 0.94 0.048 U1 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 34 1.15625 31.6875 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 U1 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 34 1.15625 31.6875 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 1-MS-003-35 U1 P007 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 35.5 1.1875 33.125 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 1-MS-004-35 U1 P008 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 35.5 1.1875 33.125 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 U1 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U1 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U1 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U1 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 Residual Heat U1 Reactor Coolant No. 1 Loop to Residual P017 M-281, M-661 1-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Heat Removal Pumps 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 U1 P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cavity Fill Pump 1A Discharge 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U1 Component Cooling Water Supply P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Header to RCPs 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U1 P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cavity Fill Pump 1B Discharge 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U1 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 Residula Heat U1 Residual Heat Exchanger to RC Loop P022 M-281, M-661 1-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 U1 RC Pumps to Comp Cooling Pump P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Suction 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U1 P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U1 RC Pumps to Comp Cooling Pump P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Suction 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 U1 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Demin Water 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 B-278, M-7, B-223, M- Pipe in U1 P035 170, 1SI-008-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 B-278, M-7, B-223, M- Pipe in U1 P036 170, 1CF-002-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 B-278, M-7, B-223, M- Pipe in U1 P037 170, 1CF-001-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 1-WO-95-1 U1 CTMT Sump Pump Dischage to Aux P042 M-281, M-661 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Bld Flr Drain Analysis Tank 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 U1 RC Drain Pump Discharge to Hold-Up P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Tank 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U1 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 Containment U1 P054 M-281, M-661 1-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Containment Pressure 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 U1 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Filtered Vents 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U1 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 1-VC-033,043, U1 P066 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RC Pump Seal Water Supply Lines 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 U1 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U1 P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1C 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 Page 105 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U1 P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1A 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 U1 Refueling Cavity Drain to Purification P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 1-BD-001-2 U1 P071 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Steam Generator Blowdown 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U1 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U1 P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1D 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 U1 P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Accumulator Tank Sample 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U1 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Non-Filtered Vents 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U1 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 U1 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 1-SS-001,2,3- U1 Press Stem, Press Liq, RC Hot Leg P086 M-282, M-661 3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Samples 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 U1 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 U1 P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Heating System Hot Water Supply 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U1 P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Heating System Hot Water Return 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U1 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 1-BD-007-2 U1 P091 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U1 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U1 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-005-2 U1 P094 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U1 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U1 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U1 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U1 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U1 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 U1 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 CTMT Aux SIM to Aux F.S. Pumps 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 Residula Heat U1 Residual Heat Exchanger to RC Loop P105 M-282, M-662 1-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Hot Legs 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 U1 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 U1 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 1-BD-003-2 U1 P115 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U1 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U1 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-001-2 U1 P118 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 B-278, M-7, B-223, M- Pipe in U1 P123 170, 1SI-007-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 Page 106 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 B-278, M-7, B-223, M- Pipe in U1 P124 170, 1SI-009-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 U1 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 U1 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 U2 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Fire Protection 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.075 U2 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 U2 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 U2 P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Boron Injection Tank to Cold Legs 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 U2 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 34 1.15625 31.6875 4 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 U2 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 34 1.15625 31.6875 4 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 2-MS-003-35 U2 P207 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 35.5 1.1875 33.125 4 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 2-MS-004-35 U2 P208 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Main Steam 35.5 1.1875 33.125 4 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 U2 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U2 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U2 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 U2 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Feedwater 16 1.218 13.564 4 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 Residula Heat U2 Reactor Coolant No. 1 Loop to Residual P217 M-281, M-661 2-RH-015-14" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Heat Removal Pumps 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 U2 P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cavity Fill Pump 1A Discharge 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U2 Component Cooling Water Supply P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Header to RCPs 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U2 P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cavity Fill Pump 1B Discharge 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U2 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 Residula Heat U2 Residual Heat Exchanger to RC Loop P222 M-281, M-661 2-RH-006-12" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Cold Legs 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 U2 RC Pumps to Comp Cooling Pump P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Suction 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U2 P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U2 RC Pumps to Comp Cooling Pump P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Suction 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 U2 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 CTMT Aux Demin Water 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 B-278, M-7, B-223, M- Pipe in U2 P235 170, 2SI-008-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 B-278, M-7, B-223, M- Pipe in U2 P236 170, 2CF-002-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 B-278, M-7, B-223, M- Pipe in U2 P237 170, 2CF-001-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 2-WO-95-1 U2 CTMT Sump Pump Dischage to Aux P242 M-281, M-661 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Bld Flr Drain Analysis Tank 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 U2 RC Drain Pump Discharge to Hold-Up P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Tank 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U2 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 Containment U2 P254 M-281, M-661 2-CS-063-2" Pressure Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Containment Pressure 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 Page 107 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 U2 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Filtered Vents 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U2 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 2-VC-033,043, U2 P266 M-281, M-661 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 CTMT Aux RC Pump Seal Water Supply Lines 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 U2 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U2 P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1C 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 U2 P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1A 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 U2 Refueling Cavity Drain to Purification P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 2-BD-001-2 U2 P271 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Steam Generator Blowdown 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U2 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 U2 P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Aux Feedwater to Steam Gen 1D 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 U2 P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Accumulator Tank Sample 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 U2 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Non-Filtered Vents 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 U2 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 U2 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 2-SS-001,2,3- U2 Press Stem, Press Liq, RC Hot Leg P286 M-282, M-661 3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Samples 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 U2 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 U2 P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Heating System Hot Water Supply 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U2 P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Heating System Hot Water Return 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 U2 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 2-BD-007-2 U2 P291 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U2 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U2 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-005-2 U2 P294 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U2 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U2 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U2 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U2 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 U2 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 CTMT Aux Spare 0 0 0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 U2 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 CTMT Aux SIM to Aux F.S. Pumps 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 Residual Heat U2 Residual Heat Exchanger to RC Loop P305 M-282, M-662 2-SI-011-10" Removal Bld to Bld Pen Open Sleeve Class 1 CTMT Aux Hot Legs 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 U2 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 U2 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Page 108 of 123

Attachment I TSD # 14-016 Auxiliary Building Affiliated Penetrations and Piping List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 2-BD-003-2 U2 P315 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U2 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 U2 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-001-2 U2 P318 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 B-278, M-7, B-223, M- Pipe in U2 P323 170, 2SI-007-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 B-278, M-7, B-223, M- Pipe in U2 P324 170, 2SI-009-20" Drain Bld to Bld Pen Sleeve Class 1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 U2 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 U2 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Page 109 of 123

Attachment J TSD # 14-016 Turbine Building Affiliated Penetrations and Piping Revision 00 Turbine Building Affiliated Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 36 3 G 16 586 586 17.77 9.42 0.91 1.65 0.267 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 36 3 G 16 578.25 578.25 3.16 0.33 0.91 0.29 0.009 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 36 3 G 16 586 586 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 36 3 G 23 586 586 17.77 9.42 0.91 1.65 0.267 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 36 3 G 23 588 588 3.16 0.33 0.91 0.29 0.009 Main A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Stm Aux Fire Protection 10.75 0.365 10.02 36 3 H 10 571 571 7.87 1.89 0.91 0.73 0.054 A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 36 3 G 13 569.75 569.75 3.16 0.33 0.91 0.29 0.009 A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 36 3 G 13 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 36 3 G 13 573.25 573.25 2.41 0.20 0.91 0.22 0.006 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 36 3 G 14 572.25 572.25 7.87 1.89 0.91 0.73 0.054 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 36 3 G 17 574.5 574.5 1.62 0.09 0.91 0.15 0.003 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 36 3 G 17 565.5 565.5 2.41 0.20 0.91 0.22 0.006 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 36 3 G 17 573.17 573.17 3.16 0.33 0.91 0.29 0.009 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 36 3 G 17 570.5 570.5 14.77 6.54 0.91 1.37 0.185 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 36 3 G 13 571 571 4.76 0.72 0.91 0.44 0.020 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 24 2 H 10 571 571 6.87 2.14 0.61 0.64 0.061 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 36 3 G 23 586.5 586.5 7.87 1.89 0.91 0.73 0.054 Main A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Stm Aux Fire Protection 10.75 0.365 10.02 36 3 H 30 571 571 7.87 1.89 0.91 0.73 0.054 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 36 3 G 17 573.42 573.42 2.41 0.20 0.91 0.22 0.006 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 36 3 G 24 576.25 576.25 2.41 0.20 0.91 0.22 0.006 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 36 3 G 24 568.75 568.75 2.41 0.20 0.91 0.22 0.006 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 36 3 G 24 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 36 3 G 24 573 573 4.76 0.72 0.91 0.44 0.020 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 36 3 G 24 571 571 13.25 5.30 0.91 1.23 0.150 Service Water Supply A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Header 36 0.75 34.5 36 3 G 23 575 575 27.10 21.21 0.91 2.52 0.600 Service Water Supply to Service Water to Diesel Generator Heat A027 M-102, M-168. M-185 OSW-008-12" DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 894 74.5 G 10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 Service Water to A028 M-102, M-168. M-185 OSW-008-12" DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 932.04 77.67 G 10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 Service Water Supply to Diesel Generator Heat A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 894 74.5 G 30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 Service Water Supply to Diesel Generator Heat A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Exchangers 12.75 0.406 11.938 932.04 77.67 G 30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 See Multiple CTMT to Aux Pens on M-282 and Main M-662 cover in CTMT A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Stm Worksheet 14 0.438 13.124 24 2 H 30 571 571 6.87 1.88 0.61 0.64 0.053 Main U1 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 34 1.15625 31.6875 48 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 Main U1 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 34 1.15625 31.6875 48 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 1-MS-003-35 Main U1 P007 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 35.5 1.1875 33.125 48 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 1-MS-004-35 Main U1 P008 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 35.5 1.1875 33.125 48 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 Main U1 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U1 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U1 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U1 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 Page 110 of 123

Attachment J TSD # 14-016 Turbine Building Affiliated Penetrations and Piping Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 1-BD-007-2 Main U1 Blowdown Steam P091 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.875 0.276 2.323 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 Blowdown Steam P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.375 0.218 1.939 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 Blowdown Steam P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.375 0.218 1.939 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-005-2 Main U1 Blowdown Steam P094 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.875 0.276 2.323 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 Blowdown Steam P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.375 0.218 1.939 48 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U1 Blowdown Steam P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.375 0.218 1.939 48 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U1 Blowdown Steam P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D 2.375 0.218 1.939 48 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U1 Blowdown Steam P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B 2.375 0.218 1.939 48 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U1 Steam Generator P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 0.675 0.065 0.545 48 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Main U1 Steam Generator P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 0.675 0.065 0.545 48 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 1-BD-003-2 Main U1 Blowdown (Steam P115 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 2.875 0.276 2.323 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 Blowdown (Steam P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 2.375 0.218 1.939 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 Blowdown (Steam P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 2.375 0.218 1.939 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 1-BD-001-2 Main U1 Blowdown (Steam P118 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 2.875 0.276 2.323 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U1 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Main U1 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Main U2 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 34 1.15625 31.6875 48 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 Main U2 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 34 1.15625 31.6875 48 4 213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 2-MS-003-35 Main U2 P207 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 35.5 1.1875 33.125 48 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 2-MS-004-35 Main U2 P208 M-281, M-661 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Main Steam 35.5 1.1875 33.125 48 4 333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 Main U2 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U2 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U2 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 Main U2 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Feedwater 16 1.218 13.564 48 4 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 2-BD-007-2 Main U2 Blowdown Steam P291 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.875 0.276 2.323 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 Blowdown Steam P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.375 0.218 1.939 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 Blowdown Steam P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.375 0.218 1.939 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-005-2 Main U2 Blowdown Steam P294 M-281, M-661 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.875 0.276 2.323 48 4 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 Blowdown Steam P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1A 2.375 0.218 1.939 48 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U2 Blowdown Steam P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1C 2.375 0.218 1.939 48 4 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U2 Blowdown Steam P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D 2.375 0.218 1.939 48 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Main U2 Blowdown Steam P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B 2.375 0.218 1.939 48 4 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 Page 111 of 123

Attachment J TSD # 14-016 Turbine Building Affiliated Penetrations and Piping Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Main U2 Steam Generator P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 0.675 0.065 0.545 48 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Main U2 Steam Generator P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Blowdown Sample 0.675 0.065 0.545 48 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 2-BD-003-2 Main U2 Blowdown (Steam P315 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 2.875 0.276 2.323 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 Blowdown (Steam P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1D) 2.375 0.218 1.939 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 Blowdown (Steam P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 2.375 0.218 1.939 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 2-BD-001-2 Main U2 Blowdown (Steam P318 M-282, M-662 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Generator 1B) 2.875 0.276 2.323 48 4 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 Main U2 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Main U2 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Stm CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 Service Water Return from Diesel Generator T032 M-103 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Heat Exchangers 16 0.5 15 2201.625 183.4688 G 31 553.83 567.5 720.48 225.15 55.92 66.93 6.376 Service Water Return from to Diesel Generator T033 M-104 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Heat Exchangers 16 0.5 15 2205 183.75 G 10 553.83 567.5 721.58 225.50 56.01 67.04 6.385 Main T034a M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Stm Blank Sleeve 14 0 14 24 2 H 31 587.75 587.75 7.33 2.14 0.61 0.68 0.061 Main T034b M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Stm Blank Sleeve 14 0 14 24 2 H 10 587.75 587.75 7.33 2.14 0.61 0.68 0.061 Bld to Yard T035 M-106, M-107 0 Fire Protection Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 36 3 J 5 583.5 584.5 7.87 1.64 0.91 0.73 0.047 Bld to Yard T036 M-106, M-107 0 Fire Protection Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 36 3 J 35 583.5 584.5 7.87 1.64 0.91 0.73 0.047 Diesel Oil Tank Fill Line T068 M-104, M-562 2DO-006-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG Yard length to 588' elevation 4.5 0.237 4.026 48 4 G 5 585.25 593 4.22 0.35 1.22 0.39 0.010 T069 M-104, M-562, M-663 2DO-004-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 18 1.5 G 6 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T070 M-104, M-562, M-663 2DO-001-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 18 1.5 G 7 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T070a M-104 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG TB Open Sleeve 8 0 0 18 1.5 G 8 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T071 M-103, M-214, M-244 1DO-010-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 18 1.5 G 32 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T072 M-103, M-214, M-244 1DO-003-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 18 1.5 G 33 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T073 M-103, M-214, M-244 1DO-002-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8 0 0 18 1.5 G 34 585.17 585.17 3.14 0.52 0.46 0.29 0.015 Bld to Yard T074 M-103, M-214 1DO-001-4" Diesel Oil Pen Buried Pipe Class 3 DG Yard Diesel Oil see buried pipe 4.5 0.237 4.026 627 52.25 G 35 585.25 593 55.07 4.62 15.93 5.12 0.131 Bld to Yard T091 M-104, M-106 Det B Spare N/A Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 10.75 0.365 10.02 60 5 C 16 585 585 13.12 2.74 1.52 1.22 0.078 Bld to Yard T092 M-104, M-106 Det B Spare N/A Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 12.75 0.406 11.938 60 5 C 16 586 586 15.63 3.89 1.52 1.45 0.110 Bld to Yard T093 M-104, M-106 Det B Spare N/A Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 14 0.438 13.124 60 5 C 16 585 585 17.18 4.70 1.52 1.60 0.133 Bld to Yard Fibercast Makeup Demin T094 M-104 0 Make-Up Demin Pen Pipe in Pen Class 3 TB Yard Waste Discharge 8.625 0.322 7.981 48 4 C 17 586 586 8.36 1.39 1.22 0.78 0.039 Bld to Yard Primary Water Storage T095 M-104, M-105 0 Primary Water Pen Pipe in Pen Class 3 TB Yard Tank 6.625 0.28 6.065 1420 118.33 C 18 556.75 556.75 187.89 23.74 36.07 17.46 0.672 Bld to Yard T096 M-103 0 Oil Seperator Pen Pipe in Pen Class 3 TB Yard Oil Seperator Tank 10.75 0.365 10.02 48 4 C 23 586 586 10.49 2.19 1.22 0.97 0.062 Bld to Yard Fibercast Makeup Demin T097 M-103 0 Make-Up Demin Pen Pipe in Pen Class 3 TB Yard Waste Discharge 8.625 0.322 7.981 48 4 C 23 586 586 8.36 1.39 1.22 0.78 0.039 Waste Discharge (WD) from Lake Discharge Bld to Yard Tank to Discharge T098 M-103 0 Waste Discharge Pen Pipe in Pen Class 1 TB Yard Tunnel 6.625 0.28 6.065 48 4 C 24 586 586 6.35 0.80 1.22 0.59 0.023 Bld to Yard T099 M-103, M-106 Det B Spare N/A Pen Pipe in Pen Class 3 TB Yard Spares 10.75 0.365 10.02 60 5 C 24 585 585 13.12 2.74 1.52 1.22 0.078 Bld to Yard T100 M-103, M-106 Det B Spare N/A Pen Pipe in Pen Class 3 TB Yard Spares 12.75 0.406 11.938 60 5 C 24 586 586 15.63 3.89 1.52 1.45 0.110 Bld to Yard T101 M-103, M-106 Det B Spare N/A Pen Pipe in Pen Class 3 TB Yard Spares 14 0.438 13.124 60 5 C 24 585 585 17.18 4.70 1.52 1.60 0.133 Page 112 of 123

Attachment J TSD # 14-016 Turbine Building Affiliated Penetrations and Piping Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Azimuth Azimuth Surface Space Int Void Pen U1 Line Ident MARSSIM OD Wall Pipe ID Length Length Degrees Degrees End Area Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Bld to Yard Primary Water Supply T102 M-104, M-105 0 Primary Water Pen Pipe in Pen Class 3 TB Yard Header to RCP 6.625 0.28 6.065 940 78.33 C 17 586 586 124.38 15.72 23.88 11.56 0.445 Condensate to Alternate M-105 SH 1 & SH 2, Bld to Yard Feedwater Pumps- Buried T103 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard Section 20 0.594 18.812 2712.59 226.05 B 21 586 586 1020.52 367.34 68.90 94.81 10.402 Bld to Yard T104 M-104 0 Waste Discharge Pen Pipe in Pen Class 1 TB Yard Lake Discharge tank 6.625 0.28 6.065 48 4 C 17 586 586 6.35 0.80 1.22 0.59 0.023 Bld to Yard T105 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard Condensate Pump Recirc 4.5 0.337 3.826 2652.59 221.05 G 22 560 586 6219.50 14.99 67.38 577.81 0.424 Bld to Yard To condensate transfer T106 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard and makeup pumps 12.75 0.406 11.938 251.13 20.93 D 22 560 583.25 65.41 16.27 6.38 6.08 0.461 Page 113 of 123

Attachment J TSD # 14-016 Turbine Building Affiliated Penetrations and Piping Revision 00 Turbine Building Drains Interior Void Pipe Pipe Surface Space Int Void Pen MARSSIM OD Wall ID Length End Area Volume Length SA Space No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet Elevation Elevation ft2 ft3 meters m2 m3 T147 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe West Wall 6 0.28 5.44 200 560 557 284.84 32.28 60.96 26.46 0.914 T148 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe North Wall 6 0.28 5.44 100 560 557 142.42 16.14 30.48 13.23 0.457 T149 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-2 Equip Drain Sump, 6 pipe West Wall 6 0.28 5.44 200 560 557 284.84 32.28 60.96 26.46 0.914 T150 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump, West-most 6 pipe on North Wall 6 0.28 5.44 100 560 557 142.42 16.14 30.48 13.23 0.457 T151 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump East-most 4 pipe on North Wall 4 0.237 3.526 100 560 557 92.31 6.78 30.48 8.58 0.192 T152 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, South-most 4 pipe on West Wall 4 0.237 3.526 150 560 557 138.47 10.17 45.72 12.86 0.288 T153 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, North-most 8 pipe on West Wall 8 0.322 7.356 450 560 557 866.61 132.81 137.16 80.51 3.761 T154 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 8 pipe on North Wall 8 0.322 7.356 450 560 557 866.61 132.81 137.16 80.51 3.761 T155 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 10 pipe on North Wall 10 0.365 9.27 80 560 557 194.15 37.50 24.38 18.04 1.062 T156 M-103 , B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, East-most 10 pipe on North Wall 10 0.365 9.27 100 560 557 242.69 46.87 30.48 22.55 1.327 Page 114 of 123

Attachment K TSD # 14-016 Waste Water Treatment Facility Penetrations and Piping Revision 00 Y or Unit X or Unit 1 2 Void Pipe Azimuth Azimuth Interior Space Void MARSSIM OD Wall Pipe ID Length Degrees - Degrees - End Surface Volume Length Int SA Space Pen No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 W001 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Force Main from Turbine Fire Sump 8.625 0.322 7.981 1 D 2 586.6667 586.6667 2.09 0.35 0.30 0.19 0.010 W002 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Heater bay roof drain lines 6.625 0.28 6.065 1 D 2 585.2 585.2 1.59 0.20 0.30 0.15 0.006 W003 B-1003, B-1005 Sludge Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sludge Line from Outdoor Drying Beds 3.5 0.216 3.068 1 A 6 587 587 0.80 0.05 0.30 0.07 0.001 W004 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTH WWTF Sludge drying bed filtrate 6.625 0.28 6.065 1 A 4 588 588 1.59 0.20 0.30 0.15 0.006 W005 B-1003, B-1005 Water Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Water Line from Yard 2.375 0.154 2.067 1 A 3 588 588 0.54 0.02 0.30 0.05 0.001 W006 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Cement Wrapped Ductile Pipe 8.625 0.322 7.981 1 A 2 586.75 586.75 2.09 0.35 0.30 0.19 0.010 W007 B-1003, B-1005 Sanitary Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sanitary Line 1.9 0.145 1.61 1 A 2 587 587 0.42 0.01 0.30 0.04 0.0004 W008 B-1003, B-1005 Service Air Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Service Air Line 1.9 0.145 1.61 1 A 2 586.75 586.75 0.42 0.01 0.30 0.04 0.0004 Page 115 of 123

Attachment L TSD # 14-016 Crib House Penetrations and Piping Revision 00 Y or Unit X or Unit Void Sleeve Pipe Pipe 1 Azimuth 2 Azimuth Interior Space Int Void Pen U1 Line Ident MARSSIM Size OD Wall ID Length Degrees - Degrees - End Surface Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 Fire Line Below to C001 M-105 SH 1 & 2, M-271 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard ForeBay 0 10.75 0.365 10.02 4 AA 111 581.75 581.75 0.87 2.19 1.22 0.08 0.062 C002 M-106, M-272 OSA-002-3" Station Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Station Air 6 3.5 0.216 3.068 4 AA 111 581 581 0.52 0.79 1.22 0.05 0.022 C003 M-106, M-272 0 Control Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Control Air 6 2.375 0.154 2.067 4 AA 111 581 581 0.52 0.79 1.22 0.05 0.022 C004 M-106, M-272 OHS-020-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Supply 6 3.5 0.216 3.068 4 AA 111 581.5 581.5 0.52 0.79 1.22 0.05 0.022 C005 M-106, M-272 OHS-024-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Return 6 2.375 0.154 2.067 4 AA 111 581.5 581.5 0.52 0.79 1.22 0.05 0.022 C006 M-106, M-272 OMU-031-3" Filtered Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Filtered Water 0 3.5 0.216 3.068 4 AA 111 581.5 581.5 0.27 0.21 1.22 0.02 0.006 Fire Line Below to C007 M-106, M-272 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard ForeBay 0 10.75 0.365 10.02 4 AA 111 585.75 585.75 0.87 2.19 1.22 0.08 0.062 M-104 & M-105 sh 1, M-102, M- Service Water Supply C026c 168 OSW-014-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Header Crib Pen 0 48 0.625 46.75 4 AA 19 579 579 4.08 47.68 1.22 0.38 1.350 M-104 & M-105 sh 1, M-102, M- Service Water Supply C029c 168 OSW-013-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Header Crib Pen 0 48 0.625 46.75 4 AA 21 579 579 4.08 47.68 1.22 0.38 1.350 Page 116 of 123

Attachment M TSD # 14-016 Fuel Handling Building Affiliated Penetrations and Piping Revision 00 Y or Unit X or Unit 1 2 Void Azimuth Azimuth Interior Space Int Void Pen U1 Line Ident MARSSIM Pipe OD Wall Pipe ID Length Degrees - Degrees - End Surface Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 M-107 Sh 1, 2 ,3 , M-197, Spent Fuel Pool - Demin Spent Fuel Pool -

A029 M-106 Sect K-K 1SF-017-2" Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 89.58 R 24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 M-107 Sh 1, 2 ,3 , M-197, A036 M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 24 570 0 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-197, Spent Fuel Pit Tell Tale A037 M-106 Sect K-K 1AD-149-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M-197, Spent Fuel Pit Tell Tale A038 M-106 Sect K-K 1AD-148-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M-197, Spent Fuel Pit Tell Tale A039 M-106 Sect K-K 1AD-147-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 24 571 Unknown 7.48 0.25 5.41 0.70 0.007 M-107 Sh 1, 2 ,3 , M-197, A040 M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R 24 569.33 584 131.25 11.01 37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M-197, A041 M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R 24 569.33 583 39.69 1.33 28.70 3.69 0.038 M-107 Sh 1, 2 ,3 , M-197, A042 M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R 24 570.58 484 34.39 1.48 19.37 3.19 0.042 M-107 Sh 1, 2 ,3 , M-197, A043 M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R 24 570.58 584 96.00 8.05 27.76 8.92 0.228 M-107 Sh 1, 2 ,3 , M-197, A044 M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R 24 570.58 584 50.10 2.16 28.22 4.65 0.061 M-107 Sh 1, 2 ,3 , M-197, A046 M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94 R 24 570.58 584 39.62 1.33 28.65 3.68 0.038 M-107 Sh 1, 2 ,3 , M-197, A047 M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R 24 569.33 583 67.80 4.33 25.73 6.30 0.123 M-107 Sh 1, 2 ,3 , M-197, A048 M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86 R 24 569.33 583 46.54 2.00 26.21 4.32 0.057 M-107 Sh 1, 2 ,3 , M-197, A049 M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R 24 570.58 584 335.99 70.14 39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M-197, A050 M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R 24 570.58 584 343.42 71.69 39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M-260, A051 M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 16 570 573 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M-260, Spent Fuel Pit Tell Tale A052 M-106 Sect K-K 2AD-149-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M-260, Spent Fuel Pit Tell Tale A053 M-106 Sect K-K 2AD-148-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M-260, Spent Fuel Pit Tell Tale A054 M-106 Sect K-K 2AD-147-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 16 571 Unknown 7.48 0.25 5.41 0.70 0.007 M-107 Sh 1, 2 ,3 , M-260, A055 M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R 16 569.33 583 61.28 2.64 34.52 5.69 0.075 M-107 Sh 1, 2 ,3 , M-260, A056 M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111 R 16 569.33 583 89.16 5.70 33.83 8.28 0.161 M-107 Sh 1, 2 ,3 , M-260, A057 M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.5 R 16 569.33 583 87.95 5.62 33.38 8.17 0.159 M-107 Sh 1, 2 ,3 , M-260, Decon Pad Drain to A058 M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Chem Drain Tank 2.375 0.154 2.067 89.75 R 16 569.33 583 48.57 2.09 27.36 4.51 0.059 M-107 Sh 1, 2 ,3 , M-260, A059 M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R 16 570.58 584 284.84 59.46 33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M-260, A060 M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R 16 570.58 584 279.16 58.27 32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M-260, A061 M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R 16 569.33 583 103.01 6.58 39.09 9.57 0.186 M-107 Sh 1, 2 ,3 , M-197, A062 M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R 16 570.58 584 136.67 11.46 39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M-260, A063 M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R 16 570.58 583 101.74 6.50 38.61 9.45 0.184 M-107 Sh 1, 2 ,3 , M-260, A064 M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R 16 570.58 584 79.94 4.11 37.69 7.43 0.116 M-107 Sh 1, 2 ,3 , M-260, A065 M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R 16 569.33 584 100.13 6.40 38.00 9.30 0.181 M-107 Sh 1, 2 ,3 , M-260, A066 M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.5 R 16 569.33 583 52.48 1.76 37.95 4.88 0.050 Page 117 of 123

Attachment M TSD # 14-016 Fuel Handling Building Affiliated Penetrations and Piping Revision 00 Y or Unit X or Unit 1 2 Void Azimuth Azimuth Interior Space Int Void Pen U1 Line Ident MARSSIM Pipe OD Wall Pipe ID Length Degrees - Degrees - End Surface Volume Length SA Space No. Drawings No. System Category End Sate Class From To Description inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 M-281, B-213 Detail 4, M- Pipe in U1 P049 661 0 Cavity Bld to Bld Pen Sleeve Class 1 CTMT SFB Fuel Transfer Tube 24 0.688 22.624 8.21 90 270 578.54 578.5417 48.62 22.92 2.50 4.52 0.649 M-281, B-213 Detail 4, M- Pipe in U2 P249 661 0 Cavity Bld to Bld Pen Sleeve Class 1 CTMT SFB Fuel Transfer Tube 24 0.688 22.624 8.21 90 270 578.54 578.5417 48.62 22.92 2.50 4.52 0.649 Page 118 of 123

Attachment N TSD # 14-016 Buried Pipe List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM OD Wall ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 Service Water Supply to Diesel A027 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 74.5 G 10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A028 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 77.67 G 10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pool - Demin Bld to Yard A029 197, M-106 Sect K-K 1SF-017-2" Water Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool - Demin Water 2.375 0.154 2.067 89.58 R 24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 Service Water Supply to Diesel A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 74.5 G 30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 Service Water Supply to Diesel A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Generator Heat Exchangers 12.75 0.406 11.938 77.67 G 30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 M-107 Sh 1, 2 ,3 , M- Bld to Yard A036 197, M-106 Sect K-K 1SI-012-24" Safety Injection Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 24 570 0 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A037 197, M-106 Sect K-K 1AD-149-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A038 197, M-106 Sect K-K 1AD-148-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 24 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A039 197, M-106 Sect K-K 1AD-147-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 24 571 Unknown 7.48 0.25 5.41 0.70 0.007 M-107 Sh 1, 2 ,3 , M- Bld to Yard A040 197, M-106 Sect K-K 1AD-146-4" Aerated Drain Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R 24 569.33 584 131.25 11.01 37.96 12.19 0.312 M-107 Sh 1, 2 ,3 , M- Bld to Yard A041 197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R 24 569.33 583 39.69 1.33 28.70 3.69 0.038 M-107 Sh 1, 2 ,3 , M- Bld to Yard A042 197, M-106 Sect K-K ODW-100-2" Demin Water Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R 24 570.58 484 34.39 1.48 19.37 3.19 0.042 M-107 Sh 1, 2 ,3 , M- Bld to Yard A043 197, M-106 Sect K-K OFP-016-4" Fire Protection Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R 24 570.58 584 96.00 8.05 27.76 8.92 0.228 M-107 Sh 1, 2 ,3 , M- Bld to Yard A044 197, M-106 Sect K-K 1SW-181-2" Service Water Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R 24 570.58 584 50.10 2.16 28.22 4.65 0.061 M-107 Sh 1, 2 ,3 , M- Bld to Yard A046 197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94 R 24 570.58 584 39.62 1.33 28.65 3.68 0.038 M-107 Sh 1, 2 ,3 , M- Bld to Yard A047 197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R 24 569.33 583 67.80 4.33 25.73 6.30 0.123 M-107 Sh 1, 2 ,3 , M- Bld to Yard A048 197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86 R 24 569.33 583 46.54 2.00 26.21 4.32 0.057 M-107 Sh 1, 2 ,3 , M- Bld to Yard A049 197, M-106 Sect K-K 1CC-078-10" Component Cooling Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R 24 570.58 584 335.99 70.14 39.04 31.21 1.986 M-107 Sh 1, 2 ,3 , M- Bld to Yard A050 197, M-106 Sect K-K 1CC-080-10" Component Cooling Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R 24 570.58 584 343.42 71.69 39.90 31.91 2.030 M-107 Sh 1, 2 ,3 , M- Bld to Yard A051 260, M-106 Sect K-K 2SI-012-24" Safety Injection Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R 16 570 573 415.27 195.73 21.37 38.58 5.543 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A052 260, M-106 Sect K-K 2AD-149-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 4.05 0.14 2.93 0.38 0.004 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A053 260, M-106 Sect K-K 2AD-148-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R 16 571 Unknown 11.68 0.39 8.44 1.08 0.011 M-107 Sh 1, 2 ,3 , M- Spent Fuel Pit Tell Tale A054 260, M-106 Sect K-K 2AD-147-1 1/2" Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R 16 571 Unknown 7.48 0.25 5.41 0.70 0.007 M-107 Sh 1, 2 ,3 , M- Bld to Yard A055 260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R 16 569.33 583 61.28 2.64 34.52 5.69 0.075 M-107 Sh 1, 2 ,3 , M- Bld to Yard A056 260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111 R 16 569.33 583 89.16 5.70 33.83 8.28 0.161 M-107 Sh 1, 2 ,3 , M- Bld to Yard A057 260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.5 R 16 569.33 583 87.95 5.62 33.38 8.17 0.159 M-107 Sh 1, 2 ,3 , M- Bld to Yard Decon Pad Drain to Chem Drain A058 260, M-106 Sect K-K 0CT-061-2" Waste Drain Pen Buried Pipe Class 1 Aux SFB Tank 2.375 0.154 2.067 89.75 R 16 569.33 583 48.57 2.09 27.36 4.51 0.059 M-107 Sh 1, 2 ,3 , M- Bld to Yard A059 260, M-106 Sect K-K 2CC-078-10" Component Cooling Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R 16 570.58 584 284.84 59.46 33.10 26.46 1.684 M-107 Sh 1, 2 ,3 , M- Bld to Yard A060 260, M-106 Sect K-K 2CC-080-10" Component Cooling Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R 16 570.58 584 279.16 58.27 32.44 25.93 1.650 M-107 Sh 1, 2 ,3 , M- Bld to Yard A061 260, M-106 Sect K-K 2DW-008-3" Demin Water Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R 16 569.33 583 103.01 6.58 39.09 9.57 0.186 M-107 Sh 1, 2 ,3 , M- Bld to Yard A062 197, M-106 Sect K-K 2AD-146-4" Aerated Drain Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R 16 570.58 584 136.67 11.46 39.52 12.70 0.325 M-107 Sh 1, 2 ,3 , M- Bld to Yard A063 260, M-106 Sect K-K 2DW-014-3" Demin Water Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R 16 570.58 583 101.74 6.50 38.61 9.45 0.184 Page 119 of 123

Attachment N TSD # 14-016 Buried Pipe List Revision 00 Y or X or Unit 1 Unit 2 Interior Void Pipe Pipe Azimuth Azimuth Surface Space Int Void Pen MARSSIM OD Wall ID Length Degrees Degrees End Area Volume Length SA Space No. Drawings Line Ident No. System Category End Sate Class From To Description inches Thickness inches Feet -minutes -minutes Elevation Elevation ft2 ft3 meters m2 m3 M-107 Sh 1, 2 ,3 , M- Bld to Yard A064 260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R 16 570.58 584 79.94 4.11 37.69 7.43 0.116 M-107 Sh 1, 2 ,3 , M- Bld to Yard A065 260, M-106 Sect K-K 2SW-243-3" Service Water Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R 16 569.33 584 100.13 6.40 38.00 9.30 0.181 M-107 Sh 1, 2 ,3 , M- Bld to Yard A066 260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.5 R 16 569.33 583 52.48 1.76 37.95 4.88 0.050 M-104 & M-105 sh 1, Service Water Supply Header Bld to Yard Service Water Supply Header Aux C026 M-102, M-168 OSW-014-48" Under TB Pen Buried Pipe Class 3 Aux Yard Pen to Under TB 48 0.625 46.75 171.5 G 19 549.67 549.6667 174.92 2044.35 52.27 16.25 57.889 M-105 SH 1 & 2, M- Bld to Yard Service Water Supply Header at TB C026a 272 OSW-014-48" Service Water Supply Header Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 19 579 549.6667 38.08 445.03 11.38 3.54 12.602 M-104 & M-105 sh 1, Service Water Supply Header Bld to Yard Service Water Supply Header Aux C029 M-102, M-168 OSW-013-48" Under TB Pen Buried Pipe Class 3 Aux Yard Pen to Under TB 48 0.625 46.75 171.5 G 21 549.67 549.6667 174.92 2044.35 52.27 16.25 57.889 M-105 SH 1 & 2, M- Bld to Yard Service Water Supply Header at TB C029a 272 OSW-013-48" Service Water Supply Header Pen Buried Pipe Class 3 Aux Yard Foundation Exit 48 0.625 46.75 37.33 C 21 579 549.6667 38.08 445.03 11.38 3.54 12.602 Service Water Return from Diesel T032 M-103 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Generator Heat Exchangers 16 0.5 15 183.47 G 31 553.83 567.5 720.48 225.15 55.92 66.93 6.376 Service Water Return from to T033 M-104 & M-106 0 Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Diesel Generator Heat Exchangers 16 0.5 15 183.75 G 10 553.83 567.5 721.58 225.50 56.01 67.04 6.385 Bld to Yard T074 M-103, M-214 1DO-001-4" Diesel Oil Pen Buried Pipe Class 3 DG Yard Diesel Oil see buried pipe 4.5 0.237 4.026 52.25 G 35 585.25 593 55.07 4.62 15.93 5.12 0.131 M-105 SH 1 & SH 2, Bld to Yard Condensate to Alternate Feedwater T103 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard Pumps- Buried Section 20 0.594 18.812 226.05 B 21 586 586 1020.52 367.34 68.90 94.81 10.402 Bld to Yard T105 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard Condensate Pump Recirc 4.5 0.337 3.826 221.05 G 22 560 586 6219.50 14.99 67.38 577.81 0.424 Bld to Yard To condensate transfer and makeup T106 M-103 0 Condensate Pen Buried Pipe Class 3 TB Yard pumps 12.75 0.406 11.938 20.93 D 22 560 583.25 65.41 16.27 6.38 6.08 0.461 U2 Disch T139 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Unit 2 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569 569 2978.98 8781.78 24.51 276.76 248.672 U2 Disch T140 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Unit 2 Circ Water Ice Melting Pipe 96 1 94 25 GG 31 569 569 615.23 1204.82 7.62 57.16 34.117 Disch T141 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Unit 1 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569 569 2978.98 8781.78 24.51 276.76 248.672 Disch T142 M-100 0 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Forebay Unit 1 Circ Water Ice Melting Pipe 96 1 94 25 GG 31 569 569 615.23 1204.82 7.62 57.16 34.117 Page 120 of 123

Attachment O TSD # 14-016 Circulating Water Intake Inventory List Revision 00 Y or Unit X or Unit 1 2 Void Pipe Pipe Azimuth Azimuth Interior Space Int Void Pen MARSSIM OD Wall ID Length Degrees - Degrees - End Surface Volume Length SA Space No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 Unit 2 Blind Flange Man Entry to Circ T083 M-780, M-100, M-101, M-104 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9 D 6 564 564 83.06 60.99 2.74 7.72 1.73 Unit 2 Blind Flange Man Entry to Circ T085 M-780, M-100, M-101, M-104 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9 D 13 564 564 83.06 60.99 2.74 7.72 1.73 M-15, M-100, M-101, B-64, M- Unit 1 Blind Flange Man Enttry to Circ T087 103 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9 D 27 564 564 83.06 60.99 2.74 7.72 1.73 M-15, M-100, M-101, B-62, M- Unit 1 Blind Flange Man Enttry to Circ T088 103 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Water Intake 36 0.375 35.25 9 D 34 564 564 83.06 60.99 2.74 7.72 1.73 Unit 1 Circ water supply pipe to T109 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 34 564 564 291.38 643.47 3.20 27.07 18.22 Unit 1 Circ water supply pipe to T110 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 34 572 572 291.38 643.47 3.20 27.07 18.22 T111 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 45.625 E 34 564 564 1760.39 5089.54 13.91 163.55 144.12 T111b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 22.5 E 34 564 564 833.50 2457.10 6.86 77.44 69.58 T112 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 124.2 E 34 564 564 4600.94 13563.19 37.86 427.44 384.07 Unit 1 Circ water pipe 12' to 17' T113 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib expansion 174 1.5 171 9 E 34 558 558 402.91 1435.36 2.74 37.43 40.64 T114 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 204 1.5 201 94.67 B 31 558 558 4981.52 20860.11 28.85 462.80 590.69 T115 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 14.25 AA 20 558 558 499.12 1434.84 4.34 46.37 40.63 T116 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 19.5 AA 22 558 558 541.14 1195.02 5.94 50.27 33.84 T117 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1 106 14.25 AA 24 558 558 395.45 873.28 4.34 36.74 24.73 T118 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 114 1 112 8.25 AA 26 558 558 241.90 564.44 2.51 22.47 15.98 T119 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 120 1 118 14 AA 26 558 558 432.49 1063.21 4.27 40.18 30.11 Unit 1 Circ water supply pipe to T120 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 26 572 572 291.38 643.47 3.20 27.07 18.22 Unit 1 Circ water supply pipe to T121 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2,5 E 26 572 572 291.38 643.47 3.20 27.07 18.22 Unit 2 Circ water supply pipe to T122 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 144 1.25 141.5 45.63 E 6 564 564 1760.39 5089.54 13.91 163.55 144.12 Unit 2 Circ water supply pipe to T122b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Condenser 144 1.25 141.5 83.5 E 6 564 564 1760.39 5089.54 25.45 163.55 144.12 Unit 2 Circ water supply pipe to T123 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 6 572 572 291.38 643.47 3.20 27.07 18.22 Unit 2 Circ water supply pipe to T123a M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 6 572 572 291.38 643.47 3.20 27.07 18.22 T124 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E 6 564 564 1760.39 5089.54 13.91 163.55 144.12 T124b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 22.5 E 6 564 564 1760.39 5089.54 6.86 163.55 144.12 Unit 2 Circ water pipe 12' to 17' T125 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib expansion 144 1.25 141.5 124.2 E 6 564 564 4600.94 13563.19 37.86 427.44 384.07 Unit 2 Circ water pipe 12' to 17' T126 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib expansion 174 1.5 171 9 B 8 558 558 402.91 1435.36 2.74 37.43 40.64 T127 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 204 1.5 201 94.67 A 12 558 558 4981.52 20860.11 28.85 462.80 590.69 T128 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 14.25 AA 20 558 558 499.12 1434.84 4.34 46.37 40.63 T129 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 19.5 AA 18 558 558 541.14 1195.02 5.94 50.27 33.84 T130 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1 106 14.25 AA 16 558 558 395.45 873.28 4.34 36.74 24.73 T131 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 114 1 112 8.25 AA 14 558 558 241.90 564.44 2.51 22.47 15.98 T132 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 120 1 118 14 AA 14 558 558 432.49 1063.21 4.27 40.18 30.11 Unit 2 Circ water supply pipe to T133 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 14 572 572 291.38 643.47 3.20 27.07 18.22 Unit 2 Circ water supply pipe to T134 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Condenser 108 1 106 2.5 E 14 572 572 291.38 643.47 3.20 27.07 18.22 T143 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E 14 564 564 1760.39 5089.54 13.91 163.55 144.12 Page 121 of 123

Attachment O TSD # 14-016 Circulating Water Intake Inventory List Revision 00 Y or Unit X or Unit 1 2 Void Pipe Pipe Azimuth Azimuth Interior Space Int Void Pen MARSSIM OD Wall ID Length Degrees - Degrees - End Surface Volume Length SA Space No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet minutes minutes Elevation Elevation Area ft2 ft3 meters m2 m3 T143b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 83.5 E 14 564 564 1760.39 5089.54 25.45 163.55 144.12 T144 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 16 558 558 2493.64 9896.63 15.24 231.67 280.24 T145 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 20 558 558 2493.64 9896.63 15.24 231.67 280.24 T146 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 24 558 558 2493.64 9896.63 15.24 231.67 280.24 Page 122 of 123

Attachment P TSD # 14-016 Circulating Water Discharge Pipe Inventory Revision 00 Y or X or Unit 1 Unit 2 Void Pipe Pipe Azimuth Azimuth Interior Space Void Pen MARSSIM OD Wall ID Length Void Space Degrees Degrees End Surface Volume Length Int Space No. Drawings System Category End Sate Class From To Description inches Thickness inches Feet Volume in3 -minutes -minutes Elevation Elevation Area ft2 ft3 meters SA m2 m3 T075 M-104, B-68, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Stand Pipe 48 0.625 46.75 38.60 795132.72 F 9 588 553 472.45 460.15 11.77 43.89 13.03 T076 M-103, B-62, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Stand Pipe 48 0.625 46.75 38.60 795132.72 F 31 588 553 472.45 460.15 11.77 43.89 13.03 M-15, M-101, B- Unit 2 Circulating Water Discharge T077 100, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun from Condenser to Discharge Tunnel 145.5 0.75 144 5 977160.98 E 9 562 557 188.50 565.49 1.52 17.51 16.01 M-15, M-101, B- Unit 2 Circulating Water Discharge T078 100, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun from Condenser to Discharge Tunnel 145.5 0.75 144 5 977160.98 E 9 562 557 188.50 565.49 1.52 17.51 16.01 Unit 2 Service Water Return to T079 B-66, B-68, M-104 Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Discharge Tunnel 48 0.625 46.75 199.92 4117971.72 E 9 553.83 560 2446.80 2383.09 60.93 227.32 67.48 M-780, M-101, M- Unit 1 Circulating Water Discharge T080 103 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun from Condenser to Discharge Tunnel 145.5 0.75 144 5 977160.98 E 31 562 557 188.50 565.49 1.52 17.51 16.01 M-780, M-101, M- Unit 1 Circulating Water Discharge T081 103 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun from Condenser to Discharge Tunnel 145.5 0.75 144 5 977160.98 E 31 562 557 188.50 565.49 1.52 17.51 16.01 Unit 1 Service Water Return to T082 B-62, B-64, M-103 Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Discharge Tunnel 48 0.625 46.75 199.92 4117971.72 E 33 553.83 560 2446.80 2383.09 60.93 227.32 67.48 M-780, B-68, B-100, Unit 2 Circ Water Discharge Stand T084 B-68, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Pipe 36 0.375 35.25 29.5 345470.83 D 9 588 558.5 272.24 199.93 8.99 25.29 5.66 M-15, B-62, B-100, Unit 1 Circ Water Discharge Stand T086 B-66 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Pipe 36 0.375 35.25 29.5 345470.83 D 31 588 558.5 272.24 199.93 8.99 25.29 5.66 T135 M-104, B-68, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Hatch to Discharge Tunnel 36 0.375 35.25 4 46843.50 D 9 562 562 36.91 27.11 1.22 3.43 0.77 T136 M-103, B-62, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Hatch to Discharge Tunnel 36 0.375 35.25 4 46843.50 D 31 562 562 36.91 27.11 1.22 3.43 0.77 U2 M-1, M-2, B-39, M- Disch Unit 2 Circ Water Discharge Pipe to T137 100 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Lake Lake 168 0.75 166.5 50 13063802.54 GG 9 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 U1 M-1, M-2, B-39, M- Disch Unit 1 Circ Water Discharge Pipe to T138 100 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Tun Lake Lake 168 0.75 166.5 50 13063802.54 GG 31 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 Page 123 of 123