ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN CHAPTER 5, REVISION 1 FINAL RADIATION STATUS SURVEY PLAN

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-i TABLE OF CONTENTS

5.

FINAL STATUS SURVEY PLAN..................................................................................... 5-1 5.1.

Radionuclides of Concern and Mixture Fractions......................................................... 5-4 5.2.

Release Criteria............................................................................................................. 5-7 5.2.1.

Derived Concentration Guideline Levels for Basement Surfaces......................... 5-8 5.2.2.

Derived Concentration Guideline Levels for Soil................................................. 5-9 5.2.3.

Derived Concentration Guideline Levels for Buried Piping................................ 5-10 5.2.4.

Derived Concentration Guideline Levels for Embedded Pipe............................. 5-10 5.2.5.

Derived Concentration Guideline Levels for Penetrations.................................. 5-11 5.2.6.

Surrogate Radionuclides...................................................................................... 5-12 5.2.7.

Sum-of-Fractions................................................................................................. 5-13 5.2.8.

Dose from Groundwater...................................................................................... 5-14 5.2.9.

Demonstrating Compliance with Dose Criterion................................................. 5-14 5.2.10.

Soil Area Factors............................................................................................ 5-15 5.3.

Summary of Characterization Survey Results............................................................ 5-17 5.3.1.

Survey of Impacted Media................................................................................... 5-18 5.3.2.

Field Instrumentation and Sensitivities................................................................ 5-18 5.3.3.

Laboratory Instrument Methods and Sensitivities............................................... 5-18 5.3.4.

Summary of Survey Results................................................................................. 5-19 5.3.4.1. Impacted and Non-Impacted Areas............................................................... 5-19 5.3.4.2. Justification for Non-Impacted Areas............................................................ 5-19 5.3.4.3. Adequacy of the Characterization.................................................................. 5-19 5.3.4.4. Inaccessible or Not Readily Accessible Areas............................................... 5-20 5.4.

Decommissioning Support Surveys............................................................................ 5-22 5.4.1.

Radiological Assessment (RA)............................................................................ 5-22 5.4.2.

Remedial Action Support (In-Process) Surveys.................................................. 5-22 5.4.3.

Instrumentation for RA and RASS...................................................................... 5-22 5.4.4.

Field Screening Methods for RA and RASS....................................................... 5-23 5.4.5.

Contamination Verification Surveys (CVS) of Basement Structural Surfaces... 5-23 5.4.6.

Post-Demolition Survey....................................................................................... 5-25 5.5.

Final Status Survey of Basement Structures............................................................... 5-25 5.5.1.

Instruments Selected for Performing FSS of Basement Surfaces........................ 5-26 5.5.2.

Basement Surface FSS Units............................................................................... 5-27 5.5.2.1. Classification and Areal Coverage for FSS of Basement Surfaces............... 5-28 5.5.2.2. Sample Size Determination for FSS of Basement Surfaces.......................... 5-33 5.5.3.

Elevated Measurement Comparison for FSS of Basement Surfaces................... 5-37 5.5.4.

Survey Approach for FSS of Basement Surfaces................................................ 5-39 5.5.5.

Basement Surface FSS Data Assessment............................................................ 5-39 5.5.6.

FSS of Embedded Piping and Penetrations......................................................... 5-41 5.5.7.

Summation of Dose for Basement Structures...................................................... 5-44 5.5.7.1. Basement Surface Dose Calculation Including Multiple Survey Units......... 5-45 5.6.

Final Status Survey (FSS) Design............................................................................... 5-47 5.6.1.

Survey Planning................................................................................................... 5-47 5.6.2.

Data Quality Objectives....................................................................................... 5-48

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-ii 5.6.2.1. State the Problem........................................................................................... 5-49 5.6.2.2. Identify the Decision...................................................................................... 5-49 5.6.2.3. Identify Inputs to the Decision....................................................................... 5-49 5.6.2.4. Define the Study Boundaries......................................................................... 5-50 5.6.2.5. Develop a Decision Rule............................................................................... 5-50 5.6.2.6. Specify Limits on Decision Errors................................................................. 5-50 5.6.2.7. Optimize the Design for Obtaining Data....................................................... 5-51 5.6.3.

Area Preparation: Turnover and Control Measures............................................. 5-51 5.6.4.

Final Status Survey Design Process..................................................................... 5-52 5.6.4.1. Sample Size Determination............................................................................ 5-53 5.6.4.2. Statistical Tests.............................................................................................. 5-54 5.6.4.3. Small Areas of Elevated Activity.................................................................. 5-56 5.6.4.4. Scan Coverage............................................................................................... 5-57 5.6.4.5. Reference Grid, Sampling and Measurement Locations............................... 5-58 5.6.4.6. Investigation Process..................................................................................... 5-60 5.7.

Final Status Survey Implementation........................................................................... 5-63 5.7.1.

Survey Methods................................................................................................... 5-63 5.7.1.1. Scanning......................................................................................................... 5-63 5.7.1.2. Beta-Gamma Scanning.................................................................................. 5-64 5.7.1.3. Volumetric Sampling..................................................................................... 5-64 5.7.1.4. Fixed Measurements...................................................................................... 5-64 5.7.1.5. Surface Soils.................................................................................................. 5-65 5.7.1.6. Subsurface Soils............................................................................................. 5-66 5.7.1.7. Reuse of Excavated Soils............................................................................... 5-69 5.7.1.8. Pavement Covered Areas............................................................................... 5-69 5.7.1.9. Buried Piping................................................................................................. 5-70 5.7.1.10. Groundwater................................................................................................. 5-70 5.7.1.11. Sediments and Surface Water...................................................................... 5-71 5.7.1.12. Survey Considerations for Buildings, Structures and Equipment................ 5-71 5.8.

Final Status Survey Instrumentation........................................................................... 5-71 5.8.1.

Instrument Selection............................................................................................ 5-72 5.8.2.

Calibration and Maintenance............................................................................... 5-73 5.8.3.

Response Checks................................................................................................. 5-76 5.8.4.

Measurement Sensitivity...................................................................................... 5-76 5.8.4.1. Total Efficiency............................................................................................. 5-76 5.8.4.2. Static Minimum Detectable Concentration.................................................... 5-77 5.8.4.3. Beta-Gamma Scan Measurement Minimum Detectable Concentration........ 5-77 5.8.4.4. Gamma Scan Measurement Minimum Detectable Concentration................. 5-78 5.8.4.5. HPGe Spectrometer Analysis........................................................................ 5-79 5.8.4.6. Pipe Survey Instrumentation.......................................................................... 5-79 5.9.

Quality Assurance....................................................................................................... 5-79 5.9.1.

Project Management and Organization................................................................ 5-80 5.9.2.

Quality Objectives and Measurement Criteria..................................................... 5-80 5.9.2.1. Written Procedures......................................................................................... 5-81 5.9.2.2. Training and Qualifications........................................................................... 5-81

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-iii 5.9.2.3. Measurement and Data Acquisitions............................................................. 5-81 5.9.2.4. Instrument Selection, Calibration and Operation........................................... 5-81 5.9.2.5. Chain of Custody........................................................................................... 5-82 5.9.2.6. Control of Consumables................................................................................ 5-82 5.9.2.7. Control of Vendor-Supplied Services............................................................ 5-82 5.9.2.8. Database Control............................................................................................ 5-82 5.9.2.9. Data Management.......................................................................................... 5-82 5.9.3.

Measurement/Data Acquisition........................................................................... 5-82 5.9.3.1. Replicate Measurements and Surveys........................................................... 5-82 5.9.3.2. Duplicate and Split Samples.......................................................................... 5-83 5.9.3.3. Field Blanks and Spiked Samples.................................................................. 5-83 5.9.3.4. QC Investigations........................................................................................... 5-83 5.9.4.

Assessment and Oversight................................................................................... 5-84 5.9.4.1. Assessments................................................................................................... 5-84 5.9.4.2. Independent Review of Survey Results......................................................... 5-84 5.9.4.3. Corrective Action Process.............................................................................. 5-84 5.9.4.4. Corrective Action Process.............................................................................. 5-84 5.9.5.

Data Validation.................................................................................................... 5-84 5.9.6.

NRC Confirmatory Measurements...................................................................... 5-84 5.10.

Final Status Survey Data Assessment..................................................................... 5-85 5.10.1.

Review of DQOs and Survey Plan Design.................................................... 5-86 5.10.2.

Preliminary Data Review............................................................................... 5-86 5.10.2.1. Data Validation............................................................................................ 5-87 5.10.2.2. Graphical Data Review................................................................................ 5-87 5.10.3.

Applying Statistical Test................................................................................ 5-88 5.10.3.1. Sum-of-Fractions.......................................................................................... 5-88 5.10.3.2. Sign Test....................................................................................................... 5-89 5.10.4.

Elevated Measurement Comparison Evaluation............................................ 5-89 5.10.5.

Data Conclusions........................................................................................... 5-90 5.11.

Final Radiation Survey Reporting........................................................................... 5-91 5.11.1.

FSS Unit Release Records............................................................................. 5-91 5.11.2.

FSS Final Reports.......................................................................................... 5-92 5.12.

Surveillance Following FSS.................................................................................... 5-93 5.13.

References............................................................................................................... 5-94

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-iv LIST OF TABLES Table 5-1 Initial Suite of Radionuclides................................................................................. 5-4 Table 5-2 Dose Significant Radionuclides and Mixture........................................................ 5-5 Table 5-3 Basement DCGLs (pCi/m2)................................................................................... 5-8 Table 5-4 DCGLs for Surface Soils (Ci/g)........................................................................... 5-9 Table 5-5 DCGLs for Subsurface Soils (Ci/g)................................................................... 5-10 Table 5-6 DCGLs for Buried Piping (Ci/g)........................................................................ 5-10 Table 5-7 DCGLs for Embedded Pipe................................................................................. 5-11 Table 5-8 DCGLs for Penetrations....................................................................................... 5-12 Table 5-9 Surrogate Ratios................................................................................................... 5-13 Table 5-10 Area Factors for Surface Soils............................................................................. 5-15 Table 5-11 Area Factors for Subsurface Soils........................................................................ 5-17 Table 5-12 Number of ISOCS Measurements per FSS Unit based on Areal Coverage........ 5-34 Table 5-13 Adjusted Minimum Number of ISOCS Measurements per FSS Unit................. 5-36 Table 5-14 Basement Surface Area Factors........................................................................... 5-37 Table 5-15 Embedded Pipe and Penetration Survey Units.................................................... 5-41 Table 5-16 Dose Assigned to Clean Concrete Fill................................................................. 5-44 Table 5-17 Surface Survey Units Contributing to Each Basement........................................ 5-45 Table 5-18 Adjusted Basement Surface Areas for Area-Weighted SOF Calculation............ 5-46 Table 5-19 Recommended Survey Coverage......................................................................... 5-58 Table 5-20 Investigation Levels............................................................................................. 5-61 Table 5-21 Typical FSS Survey Instrumentation................................................................... 5-74 Table 5-22 Typical FSS Instrument Detection Sensitivities.................................................. 5-75 LIST OF FIGURES Figure 5-1 Characterization/LTP/FSS Organization Chart................................................... 5-96

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-i LIST OF ACRONYMS AND ABBREVIATIONS 1

AF Area Factor 2

ALARA As Low As Reasonably Achievable 3

AMCG Average Member of the Critical Group 4

BFM Basement Fill Model 5

BIL Basement Inventory Limit 6

CAQ Conditions Adverse to Quality 7

CCDD Clean Concrete Demolition Debris 8

CsI Cesium Iodide 9

CoC Chain of Custody 10 CVS Contamination Verification Survey 11 DCGL Derived Concentration Guideline Levels 12 DQA Data Quality Assessment 13 DQO Data Quality Objectives 14 EMC Elevated Measurement Comparison 15 ETD Easy to Detect 16 FOV Field of View 17 FRS Final Radiation Survey 18 FSS Final Status Survey 19 GPS Global Positioning System 20 HPGe High-Purity Germanium 21 HSA Historical Site Assessment 22 HTD Hard to Detect 23 IC Insignificant Contributor 24 ISFSI Independent Spent Fuel Storage Installation 25 ISOCS In Situ Object Counting System 26 LBGR Lower Bound of the Gray Region 27 LTP License Termination Plan 28 MARSSIM Multi-Agency Radiation Survey and Site Investigation Manual 29 MDC Minimum Detectable Concentration 30 MDCR Minimum Detectable Count Rate 31 NAD North American Datum 32 NaI Sodium Iodide 33 NIST National Institute of Standards and Technology 34 NRC U.S. Nuclear Regulatory Commission 35 ODCM Off Site Dose Calculation Manual 36 QA Quality Assurance 37

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-ii QAPP Quality Assurance Project Plan 38 QC Quality Control 39 RA Radiological Assessment 40 RASS Remedial Action Support Survey 41 ROC Radionuclides of Concern 42 SFP Spent Fuel Pool 43 SOF Sum of Fractions 44 SOP Standard Operating Procedures 45 STS Source Term Survey 46 TEDE Total Effective Dose Equivalent 47 TSD Technical Support Document 48 UCL Upper Confidence Level 49 VCC Vertical Concrete Cask 50 WRS Wilcoxon Rank Sum 51 WWTF Waste Water Treatment Facility 52 ZNPS Zion Nuclear Power Station 53 ZSRP Zion Station Restoration Project 54 55 56 57 58

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-1

5.

FINAL RADIATION STATUS SURVEY PLAN 59 The purpose of the Final Radiation Status Survey (FRSFSS) Plan is to describe the methods to be used 60 in planning, designing, conducting, and evaluating the FRS FSS at the Zion Station Restoration Project 61 (ZSRP). The FRS FSS Plan describes the final survey process used to demonstrate that the Zion 62 Nuclear Power Station (ZNPS) facility and site comply with the radiological criteria for unrestricted use 63 specified in 10 CFR 20.1402. Nuclear Regulatory Commission (NRC) regulations applicable to FRS 64 FSS are found in 10 CFR 50.82(a)(9)(ii)(D) and 10 CFR 20.1501(a) and (b).

65 The two radiological criteria for unrestricted use specified in 10 CFR 20.1402 are; 1) the residual 66 radioactivity that is distinguishable from background radiation results in a Total Effective Dose 67 Equivalent (TEDE) to an Average Member of the Critical Group (AMCG) that does not exceed 68 25 millirem/year (mrem/yr), including that from groundwater sources of drinking water, and 2) the 69 residual radioactivity has been reduced to levels that are As Low As Reasonably Achievable (ALARA).

70 Chapter 4 describes the methodologies and criteria that will be used to perform remediation activities 71 and to demonstrate compliance with the ALARA criterion.

72 This FRS FSS Plan has been developed using the guidance contained in the following documents:

73

  • NUREG-1575, Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) 74 (Reference 5-1),

75

  • NUREG-1505, A Nonparametric Statistical Methodology for the Design and Analysis of Final 76 Status Decommissioning Surveys (Reference 5-2),

77

  • NUREG-1507, Minimum Detectable Concentrations with Typical Radiation Survey Instruments 78 for Various Contaminants and Field Conditions (Reference 5-3),

79

  • NUREG-1700, Standard Review Plan for Evaluating Nuclear Power Reactor License Termination 80 Plans (Reference 5-4),

81

  • NUREG-1757, Volume 2, Revision 1, Consolidated Decommissioning Guidance 82 Characterization, Survey, and Determination of Radiological Criteria, Final Report (Reference 5-83 5),

84

  • Regulatory Guide 1.179, Standard Format and Content of License Termination Plans for Nuclear 85 Power Reactors (Reference 5-6).

86 Dose modeling as discussed in Chapter 6 was performed to develop the residual radioactivity levels that 87 correspond to the 25 mrem/yr dose criterion. Site-specific, concentration-based Derived Concentration 88 Guideline Levels (DCGL) were calculated for soils, buried pipe, basements surfaces, basement 89 penetrations and basement embedded pipe. The dose from basement surfaces, penetrations and 90 embedded pipe are summed to determine the total dose for a given basement.s surfaces, basement 91 penetrations basement.The dose from surfaces, penetrations and embedded pipe are summed to 92 determine the total dose for a given basement. are considered part of the basement structure. The dose 93 modeling methods and source term assumptions affect the FRS process for the various media with 94 residual radioactivity at ZNPS. The required source term for the Basement Fill Model (BFM) is the 95 total inventory summed over the remaining below ground walls and floors in each basement/structure, 96 embedded piping and penetrations. The BFM is a mixing model that is independent of the range and 97 distribution of residual radioactivity and therefore the typical concentration-based Derived 98

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-2 Concentration Guideline Levels (DCGLs) are not applicable. For soils and buried pipe, site-specific, 99 concentration-based DCGLs were calculated.

100 Because of differences in the conceptual models and required source terms, the FRS will include two 101 somewhat different approaches depending on the media; (1) Final Status Survey (FSS) will be 102 conducted in accordance with MARSSIM on soil, buried piping and groundwater to demonstrate that 103 residual radionuclide concentrations are equal to or below site-specific DCGLs, and (2) a Source Term 104 Survey (STS) will be conducted in accordance with section 5.5 of this Chapter to demonstrate that the 105 inventory of residual radioactivity in building basements, embedded piping and penetrations is below a 106 source term inventory commensurate with the dose criterion in 10 CFR 20.1402.

107 The term FRS is used in this chapter to represent both the FSS and STS surveys. When the 108 discussion applies to only one of the survey methods, either FSS or STS, they are specifically called 109 out.

110 It is ZionSolutions expectation that the NRC will choose to conduct confirmatory measurements during 111 the implementation of FSS and STS activities. ZionSolutions acknowledges that the purpose of the 112 confirmatory measurements will be to assist the NRC in making a determination that the FSS and STS 113 werewas performed in accordance with this Plan and that they verify that the site is suitable for 114 unrestricted use in accordance with the dose criterion in 10 CFR 20.1402.

115 The FRS FSS Plan includes the radiological assessment of all impacted sub-grade structures (including 116 embedded piping and penetrations), buried piping and open land areas that will remain following 117 decommissioning. DCGLs and BFM Basement Dose Factors have been established for soil/buried 118 piping and structures/embedded piping/penetrations, respectively, to determine compliance with the 119 25 mrem/yr dose criterion. It is ZionSolutions intention to release for unrestricted use the impacted 120 open land areas and remaining below grade structures and piping from the 10 CFR 50 license, with the 121 exception of the immediate area surrounding the Independent Spent Fuel Storage Installation (ISFSI),

122 through the successful implementation of this FRS FSS Plan. The ISFSI was established under the 123 general license provisions of 10 CFR 72.210. This FRS FSS Plan does not address non-impacted areas 124 as identified in Chapter 2.

125 At ZSRP, sSection 8.5 of Exhibit C, Lease Agreement, titled Removal of Improvements; Site 126 Restoration integral to the Zion Nuclear Power Station, Units 1 and 2 Asset Sale Agreement 127 (Reference 5-7) requires the demolition and removal of all on-site buildings, structures, and components 128 to a depth of at least three feet below grade. The ISFSI Monitoring Building and the ISFSI Warehouse 129 will remain, however itthey are not part of the scope and will be included as part of the ISFSI Part 50 130 license. The FSS of other minor solid items, such as but not limited to the switchyard structures, the 131 microwave tower, telephone poles, fencing, culverts, valve boxesduct banks and electrical conduit will 132 be included in the open land FSS unit in which they reside.

133 Several minor structures such as the Switchyard, the ISFSI warehouse, the microwave tower, and the 134 Sewage Lift Station, as well as all most roadways and rail lines, will remain at license termination as 135 requested by Exelon. The major structures that will remain at license termination and be subjected to 136 STSFSS, are the basements of the Unit 1 Containment Building, Unit 2 Containment Building, 137 Auxiliary Building, Turbine Building, Waste Water Treatment Facility (WWTF), the lower portion of 138 the Fuel Handling Building (FHB), including the Spent Fuel Pool (SFP) and the Fuel Transfer 139 CanalSpent Fuel Pool (SFP), the Fuel Transfer Canal, Crib House and Forebay, Unit 1 and Unit 2 140

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-3 Steam Tunnels and the Circulating Water Intake and Discharge Tunnels below the 588 foot elevation 141 (3 feet below grade). All systems, components as well as all structures above the 588 foot elevation 142 (with the exception of the minor structures previously noted) will be removed during the 143 decommissioning process and disposed of as a waste stream.

144 In both Containment basements, all concrete will be removed from the interior side of the steel liner 145 above the 565 foot elevation, leaving only the remaining exposed liner below the 588 foot elevation, the 146 concrete in the In-core Instrument Shaft leading to and including the area under vessel (or Under-Vessel 147 area), and the structural concrete outside of the liner.In both Containment basements, all concrete will 148 be removed from the interior side of the steel liner, leaving only the remaining exposed liner below the 149 588 foot elevation and the structural concrete outside of the liner. In the Auxiliary Building, all interior 150 walls and floors will be removed, leaving only the exterior walls and basement floor. In the Turbine 151 Building basement, the remaining structures will consist of reinforced concrete floors and exterior 152 foundation walls and the sub-grade portions of the pedestals below the 588 foot elevation. For the Fuel 153 Handling BuildingFHB, the only portion of the structure that will remain is the lower 12 feet of the SFP 154 below 588 foot elevation and the concrete structure of the Fuel Transfer Canals once the steel liner has 155 been removed. Other below ground structures that will remain are the lower concrete portions of the 156 WWTF, Main Steam Tunnels, and Circulating Water Inlet Piping and Discharge Tunnels.

157 The current decommissioning approach for ZSRP also calls for the beneficial reuse of concrete from 158 building demolition as clean fill. Concrete that meets the non-radiological definition of Clean Concrete 159 Demolition Debris (CCDD) and where radiological surveys demonstrate that the concrete meets the 160 criteria for unconditional release will be used. See section 2.4 of License Termination Plan (LTP) 161 Chapter 2 for additional discussion.Concrete that meets the non-radiological definition of clean concrete 162 demolition debris and where radiological surveys demonstrate that the concrete is free of plant derived 163 radionuclides above background will be used. Radiological surveys will be performed in accordance 164 with the guidance of NUREG-1575, Supplement 1, Multi-Agency Radiation Survey and Assessment of 165 Materials and Equipment Manual (MARSAME) (Reference 5-8).

166 The structural surfaces that will remain at ZNPS following the termination of the license are constructed 167 of solid steel and concrete which will be covered by at least three (3) feet of soil and physically altered 168 to a condition which would not allow the remaining structural surfaces, if excavated, to be realistically 169 occupied. Consequently, the only applicable dose pathway is from the leaching of residual radioactivity 170 concentrations in the structure concrete to groundwater. The dose model that will be used to calculate 171 and quantify the future dose from groundwater is referred to as the BFM. The approach and 172 methodologies that will be used to calculate the remaining total inventory of residual activity remaining 173 in the subsurface steel and concrete structures and the corresponding dose from groundwater are 174 described in this plan. Rather than using an adjusted gross DCGL to demonstrate compliance with the 175 release criteria, the steel and concrete walls and floors of the backfilled structures/basements will be 176 remediated to levels that are equal to or below the 25 mrem/yr dose criterion.

177 The End State will also include a range of buried piping, embedded piping and penetrations. Buried 178 piping is defined as pipe that runs through soil. An embedded pipe is defined as a pipe that runs 179 vertically through a concrete wall or horizontally through a concrete floor and is contained within a 180 given building. A penetration is defined as a pipe (or remaining pipe sleeve, if the pipe is removed, or 181 concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between 182 two buildings, and is open at the wall or floor surface of each building. A penetration could also be a 183

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-4 pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside 184 ground on the other end. The list of buried piping, penetrations and embedded piping to remain is 185 provided in ZionSolutions Technical Support Document (TSD)14-016, Description of Embedded 186 Pipe, Penetrations, and Buried Pipe to Remain in Zion End State (Reference 5-8).

187 5.1.

Radionuclides of Concern and Mixture Fractions 188 ZionSolutions Technical Support Document (TSD)11-001, Potential Radionuclides of Concern 189 during the Decommissioning of Zion Station (Reference 5-9) was prepared and approved in 190 November 2011. The purpose of this document was to establish the basis for an initial suite of potential 191 radionuclides of concern (ROC) for the decommissioning. Industry guidance was reviewed as well as 192 the analytical results from the sampling of various media from past plant operations. Based on the 193 elimination of some of the theoretical neutron activation products, noble gases and radionuclides with a 194 half-life less than two years, an initial suite of potential ROC for the decommissioning of the ZNPS was 195 prepared. The initial suite list of potential ROC is listed provided in Table 5-1.

196 Table 5-1 Initial Suite of Radionuclides 197 Radionuclide Half Life (years)

Radionuclide Half Life (years)

Radionuclide Half Life (years)

H-3 1.24 E 01 Tc-99 2.13 E 05 Pu-238 8.77 E 01 C-14 5.73 E 03 Sb-125 2.77 E 00 Pu-239/240 2.41 E 04 Fe-55 2.70 E 00 Cs-134 2.06 E 00 Pu-241 1.44 E 01 Ni-59 7.50 E 04 Cs-137 3.00 E 01 Np-237 2.14 E 06 Co-60 5.27 E 00 Pm-147 2.62 E 00 Am-241 4.32 E 02 Ni-63 9.60 E 01 Sm-146 1.03 E 08 Am-243 7.38 E 03 Sr-90 2.91 E 01 Sm-151 9.00 E 01 Cm-244 1.81 E 01 Mo-93 3.50 E 03 Eu-152 1.33 E 01 Nb-94 2.03 E 04 Eu-154 8.80 E 00 LTP Chapter 2 provides detailed characterization data that describes current contamination levels in the 198 basements and the results of surveys taken of soils. The survey data for basements is based on core 199 samples obtained at biased locations with elevated contact dose rates and/or evidence of leaks/spills.

200 Surface and subsurface soil samples were taken in each impacted open land survey units and analyzed 201 for the presence of plant-derived radionuclides. ZionSolutions TSD 14-019, Radionuclides of 202 Concern for Soil and Basement Fill Model Source Terms (Reference 5-10) evaluates the results of the 203 concrete core analysis data from the Containments and Auxiliary Building and refines the initial suite of 204 radionuclides potential ROC by evaluating the dose significance of each radionuclide. Insignificant 205 dose contributors were determined consistent with the guidance contained in Section 3.3 of NUREG-206 1757.

207 LTP Rev 1 Chapter 6, section 6.5.2 discusses the process used to derive the ROC for the 208 decommissioning of ZNPS, including the elimination of insignificant dose contributors from the initial 209

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-5 suite consistent with the guidance in Section 3.3 of NUREG-1757. Based upon the analysis of the 210 mixture in TSD 14-019, Table 19, it was determined that Co-60, Ni-63, Sr-90, Cs-134 and Cs-137 211 accounted for 99.5% of all dose in the contaminated concrete mixes. For activated concrete, H-3, Eu-212 152, and Eu-154, in addition to the five aforementioned nuclides, accounted for 99% of the dose.

213 Table 5-2 presents the ROC for the decommissioning of ZNPS and the normalized mixture fractions 214 based on the radionuclide mixture presented for the Auxiliary Building and Containment in TSD 14-215 019, Table 19.

216 Table 5-2 Dose Significant Radionuclides and Mixture 217 Radionuclide(2)

Containment Auxiliary Building(2)

% of Total Activity (normalized)(1)

% of Total Activity (normalized)(1)

H-3 0.08%

NA Co-60 4.72%

0.92%

Ni-63 26.50%

23.71%

Sr-90 0.03%

0.05%

Cs-134 0.01%

0.01%

Cs-137 68.17%

75.32%

Eu-152 0.44%

NA Eu-154 0.06%

NA (1) Based on maximum percent of total activity from Table 20 of TSD 14-019, 218 normalized to one for the dose significant radionuclides.

219 (2) Does not include dose significant radionuclides for activated concrete (H-220 3, Eu-152, Eu-154) under the assumption that all activated concrete will be 221 removed and disposed of as waste.

222 The results of surface and subsurface soil characterization in the impacted area surrounding ZNPS 223 indicate that there is minimal residual radioactivity in soil. Based on the characterization survey results 224 to date, ZSRP does not anticipate the presence of significant soil contamination in any remaining 225 subsurface soil that has not yet been characterized. In addition, based on process knowledge, minimal 226 contamination is expected in any of the buried piping that ZSRP plans to abandon in place.

227 Consequently, due to the absence of any significant source term in soil or in buried piping, the suite of 228 ROC and radionuclide mixture derived for the Auxiliary Building concrete was considered as a 229 reasonably conservative mixture to apply to soils and buried piping for FSS planning and 230 implementation.

231 LTP Chapter 6, section 6.5.2 discusses the process used to derive the final suite of dose significant ROC 232 for the decommissioning of ZNPS, including the elimination of insignificant dose contributors from the 233 ROC. Table 5-2 presents the final suite of ROC for the decommissioning of ZNPS and the normalized 234 mixture fractions based on the radionuclide distribution presented for the Auxiliary Building and soils 235 in TSD 14-019.

236

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-6 The characterization surveys of several inaccessible or not readily accessible subsurface soils or 237 structural surfaces have been deferred until safe access is available. These areas are specified in section 238 5.3.4.4 of this Chapter, as well as section 2.5 of LTP Chapter 2 and will be characterized during the 239 continuing characterization process. In order to verify that the IC dose does not change prior to 240 implementing the FSS, and to verify the HTD to surrogate radionuclide ratios used for the surrogate 241 calculation (see LTP Rev 1 Chapter 6, section 6.5.2) are still valid, ZSRP will obtain and analyze 242 concrete core and soil samples during continuing characterization (including radiological assessments) 243 and FSS as described below.

244 For continuing characterization, 10% of all media samples collected in a survey unit, with a minimum 245 of one sample, will be analyzed for the full initial suite of radionuclides. The samples selected will be 246 biased to those areas exhibiting the highest gamma activity. The IC dose will be calculated for each 247 individual sample result. If the IC dose calculated from the sample result is greater than the IC dose 248 assigned for DCGL adjustment (see LTP Chapter 6, Section 6.5.2.3), then an investigation will be 249 performed to determine if the DCGL requires readjustment. It is possible, but not likely, that the 250 continuing characterization could indicate different ROC for a given survey unit. If so, the different 251 ROC will be applied to the affected survey unit. For sample(s) with positive results for both a HTD 252 ROC and the corresponding surrogate radionuclide (Cs-137 or Co-60), the HTD to surrogate ratio will 253 be compared to the ratio assigned for use in the surrogate calculation (see section 5.2.6). If the 254 surrogate ratio from the sample exceeds the assigned ratio, then the ratio from the continuing 255 characterization sample will be applied to the FSS surrogate calculations for the survey unit.

256 Examples of areas where surveys are deferred include soils under structures, soils under concrete or 257 asphalt coverings, the underlying concrete of the SFP and Transfer Canal, the interiors of embedded 258 and/or buried pipe that may remain, and the interior and exterior of both Containment domes. As 259 currently inaccessible soils, structures and piping systems are made accessible and are surveyed, either 260 by continuing characterization or by Radiological Assessment (RA),Remedial Action Support Survey 261 (RASS) or FSS, the survey results will be reviewed to ensure that the suite of ROC and radionuclide 262 mixture derived for the Auxiliary Building is applicable.

263 Radiological Assessment (RA) surveys will be performed in currently inaccessible soil areas that are 264 exposed after removal of asphalt or concrete roadways and parking lots, rail lines, or building 265 foundation pads (slab-inon-grade). A limited number of soil samples are typically collected as a part 266 of the RA. Ten percent (10%) of any soil samples collected during an RA in a survey area, with a 267 minimum of one sample, will be analyzed for the full initial suite of radionuclides.

268 Soil samples and concrete cores will be collected during FSS to confirm the HTD to surrogate 269 radionuclide ratios used for the surrogate calculation. Only HTD radionuclides included as ROC (H-3, 270 Ni-63, Sr-90, for Containment and Ni-63 and Sr-90 for all other structures and soils) will be analyzed in 271 the FSS confirmatory samples. Concrete cores will be collected from the Auxiliary Building basement, 272 SFP/Transfer Canal, and the Under-Vessel areas in Containment where concrete will remain. The 273 number of cores collected and analyzed for ROC HTD will be ten percent (10%) of the FSS ISOCS 274 measurements. The concrete core locations will be selected from the floor and lower walls in the 275 survey unit to alleviate safety concerns from working at heights and to focus on the areas expected to 276 contain the majority of residual radioactivity. For soil, ten percent (10%) of the FSS samples collected 277 from impactedopen land survey units will also be analyzed for ROC HTD radionuclides. For soil 278 samples or concrete cores with positive results for both a HTD ROC and the corresponding surrogate 279

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-7 radionuclide (Cs-137 or Co-60), the HTD to surrogate ratio will be calculated and compared to the ratio 280 assigned for use in the surrogate calculation (see section 5.2.6). If the surrogate ratio from the sample 281 exceeds the assigned ratio, then the ratio from the sample will be applied to the FSS surrogate 282 calculations for the affected survey unit.as dose significant ( ROC basements, collected and analyzed 283 for ROC HTD. The number of cores collected will be ISOCS collected basement ROCThe concrete 284 samples taken from the underlying concrete of the SFP and Transfer Canal will be analyzed for the 285 presence of Hard-to-Detect (HTD) radionuclides. For other structural surfaces, embedded piping and 286 penetrations included in the BFM, if surveys indicates that the potential dose from residual radioactivity 287 in a structure could exceed 10% of the dose limit (2.5 mrem/yr), then the samples will be analyzed for 288 the presence of HTD radionuclides. If surveys indicate the presence of gamma-emitting radionuclides 289 at concentrations greater than 50% of a DCGL in soils or buried pipe, then the samples will be analyzed 290 for the presence of HTD radionuclides. Based upon the analysis of radionuclide fractions and dose 291 contribution in TSD 14-019 the dose contribution from HTD fractions is expected to be very low with 292 even the most extreme HTD ratios.

293 5.2.

Release Criteria 294 Before the FSS and STS process can proceed, the DCGLs and Basement Dose Factors that are used to 295 demonstrate compliance with the 25 mrem/yr unrestricted release criterion must be established. The 296 DCGLs and Basement Dose Factors are calculated by analysis of various pathways (direct radiation, 297 inhalation, ingestion, etc.), media (concrete, soils, and groundwater) and scenarios through which 298 exposures could occur. They are used in the survey design process to establish the minimum 299 sensitivities required for the available survey instruments and techniques and, in some cases, the 300 spacing of measurements or samples to be made within a survey unit. Chapter 6 of this LTP describes 301 in detail the approach, modeling parameters and assumptions used to develop the DCGLsunrestricted 302 release criterion.

303 For soil and buried pipe, concentrations are calculated that correspond to the dose criterion and are 304 referred to as DCGLs. Each radionuclide-specific DCGL is equivalent to the level of residual 305 radioactivity (above background levels) that could, when considered independently, result in a TEDE of 306 25 mrem per year to an AMCG. When applied to backfilled basements surfaces below 588 foot 307 elevation, andincludingembedded pipe and penetrations, the DCGLs are expressed in units of activity 308 per unit of area (pCi/m2). When applied to soil, the DCGLs are expressed in units of activity per unit of 309 mass (pCi/g). For buried piping, DCGLs are calculated and expressed in units of activity per surface 310 area (dpm/100 cm2).

311 Multiple ROC are known to be present at ZNPSZSRP. The dose contribution from each ROC is 312 accounted for using the Sum-of-Fractions (SOF) to ensure that the total dose from all ROC does not 313 exceed the dose criterion.

314 A DCGL that is established for the average residual radioactivity in a survey unit is called a DCGLW.

315 Values of tThe DCGLW may thencan be increased throughmultiplied by use of Area Factors (AF) to 316 obtain a DCGL that represents the same dose to an individual for residual radioactivity over a smaller 317 area within a survey unit. The scaled value is called defined as the DCGLEMC, where EMC stands for 318 elevated Elevated measurement Measurement comparisonComparison. The DCGLEMC is only 319 applicable to Class 1 survey units.

320

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-8 For basements/structures below 588 foot elevation, building-specific Basement Dose Factors are 321 calculated in units of mrem/yr per mCi. The total inventory remaining for each ROC will be multiplied 322 by the Basement Dose Factors for each radionuclide to calculate the actual dose from the remaining 323 basement source term. These Basement Dose Factors are radionuclide-specific values that are 324 determined for each ROC. Since multiple ROC are known to be present, the dose contribution from 325 each ROC is accounted for using the SOF to ensure that the total dose from all ROC does not exceed 326 the dose criterion.

327 5.2.1.

Derived Concentration Guideline Levels for Basement Surfaces Basement Dose 328 Factors for Structures, Embedded Piping and Penetrations 329 The Basement Fill Model (BFM) applies to the steel and concrete walls and floor surfaces, below the 330 588 foot elevation, of the Unit 1 Containment Building, Unit 2 Containment Building, Auxiliary 331 Building, Turbine Building, WWTF, the lower portion of the SFP, Fuel Transfer Canals, Crib House 332 and Forebay, Unit 1 and Unit 2 Steam Tunnels and the Circulating Water Intake Piping and Circulating 333 Water Discharge Tunnels. The BFM source term also includes the end-state embedded piping and 334 penetrations as specified in TSD 14-016. The DCGLs for embedded pipe and penetrations are provided 335 in sections 5.2.4 and 5.2.5. Basement surface DCGLs are in units of pCi/m2 of basement surface area 336 and are calculated in LTP Chapter 6, section 6.6.8.

337 The DCGLB is directly analogous to the DCGLW as defined in MARSSIM and is the DCGL used 338 during FSS to demonstrate compliance. The IC dose percentage of 5% for the Auxiliary Basement and 339 10% for the Containment Basement was used to adjust the DCGLB to account for the dose from the 340 eliminated IC radionuclides. The DCGLB values from LTP Chapter 6, section 6.6.8.1 are reproduced in 341 Table 5-3.

342 343 344 Table 5-3 Basement DCGLs (pCi/m2) 345 Nuclide Auxiliary Building Containment SFP/Transfer Canal Turbine Building Crib House

/Forebay WWTF H-3 5.30E+08 2.38E+08 2.38E+08 1.29E+08 1.93E+08 1.71E+07 Co-60 3.04E+08 1.57E+08 1.57E+08 7.03E+07 5.52E+07 2.83E+07 Ni-63 1.15E+10 4.02E+09 4.02E+09 2.18E+09 3.25E+09 2.89E+08 Sr-90 9.98E+06 1.43E+06 1.43E+06 7.74E+05 1.16E+06 1.03E+05 Cs-134 2.11E+08 3.01E+07 3.01E+07 1.59E+07 2.13E+07 2.31E+06 Cs-137 1.11E+08 3.94E+07 3.94E+07 2.11E+07 2.96E+07 2.93E+06 Eu-152 6.47E+08 3.66E+08 3.66E+08 1.62E+08 1.23E+08 7.55E+07 Eu-154 5.83E+08 3.19E+08 3.19E+08 1.43E+08 1.12E+08 5.74E+07 Note 1:

The DCGL for the SFP/Transfer Canal set equal to the lower of either the Auxiliary Building or Containment 346 DCGL. The Containment DCGLs were lower for all ROC, therefore the SFP/Transfer Canal DCGLs were set 347 equal to Containment DCGLs.

348

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-9 349 5.2.2.

Derived Concentration Guideline Levels for Soil 350 The results of surface and subsurface soil characterization in the impacted area surrounding ZNPS show 351 that there is minimal residual radioactivity in soil. At this time, based on the characterization survey 352 results to date, ZSRP does not anticipate the presence of significant concentrations of soil 353 contamination.

354 Surface soil is defined as soil residing in the first 0.15 m layer of soil. A subsurface soil category, 355 which is defined as a layer of soil beginning at the surface but extending to a depth of 1 m is also 356 assessed to allow for flexibility in compliance demonstration if contamination deeper than 0.15 m is 357 encountered. Site-specific DCGLs for soil were calculated for both the 0.15 m and 1 m thicknesses.

358 Based on characterization data and historical information, there are no expectations of encountering a 359 source term geometry that is comprised of a clean surface layer of soil over a contaminated subsurface 360 soil layer. ZionSolutions TSD 14-011, Soil Area Factors (Reference 5-11) and LTP Chapter 6, 361 section 6.8 provides the exposure scenarios and modeling parameters that were used to calculate the 362 site-specific soil DCGLs. The surface and subsurface soil DCGLs for the unrestricted release of open 363 land survey units are provided in Tables 5-4 and 5-5, respectively. The IC dose percentage of 10% was 364 used to adjust the DCGLs in Tables 5-4 and 5-5 to account for the dose from the eliminated IC 365 radionuclides.

366 367 Table 5-3 Basement Dose Factors (mrem/yr per mCi) 368 Nuclide Auxiliary Containment Fuel Turbine Crib House/Forebay WWTF Co-60 1.10E-02 4.13E-02 1.20E+00 1.26E-02 2.05E-02 7.57E-01 Cs-134 1.57E-02 2.16E-01 7.15E-01 5.56E-02 5.31E-02 9.27E+00 Cs-137 3.00E-02 1.65E-01 3.67E-01 4.21E-02 3.83E-02 7.31E+00 Eu-152 5.14E-03 1.77E-02 5.66E-01 5.48E-03 9.18E-03 2.83E-01 Eu-154 5.70E-03 2.04E-02 6.26E-01 6.21E-03 1.01E-02 3.73E-01 H-3 6.28E-03 2.73E-02 1.10E-08 6.88E-03 5.87E-03 1.25E+00 Ni-63 2.89E-04 1.61E-03 2.85E-06 4.06E-04 3.48E-04 7.40E-02 Sr-90 3.33E-01 4.54E+00 5.38E-03 1.15E+00 9.78E-01 2.09E+02 Table 5-4 DCGLs for Surface Soils (Ci/g) 369 Radionuclide Surface Soil DCGL (pCi/g)

Co-60 4.264.7 Cs-134 6.777.5

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-10 Cs-137 14.1815.7 Ni-63 3572.103988 Sr-90 12.0914.3 Table 5-5 DCGLs for Subsurface Soils (Ci/g) 370 Radionuclide Subsurface Soil DCGL (pCi/g)

Co-60 3.443.8 Cs-134 4.444.9 Cs-137 7.758.5 Ni-63 763.02847 Sr-90 1.661.8 5.2.3.

Derived Concentration Guideline Levels for Buried Piping 371 The residual radioactivity in buried piping located below the 588 foot grade that will remain and be 372 subjected to FSS is discussed in LTP Chapter 2, section 2.3.3.7 and TSD 14-016 and presented in 373 Table 2-27. The dose assessment methods and resulting DCGLs for buried piping are described in 374 detail in TSD 14-015, Buried Pipe Dose Modeling & DCGLs (Reference 5-12) and LTP Chapter 6, 375 section 6.12. Site-specific DCGLs were developed based on a reasonable exposure scenario for a range 376 of buried pipe diameters. Table 5-6 presents the buried piping DCGLs from LTP Chapter 6, section 377 6.12TSD 14-015 based upon the most conservative values for each ROC.

378 Table 5-6 DCGLs for Buried Piping (Ci/g) 379 Radionuclide Buried Piping DCGL (dpm/100 cm2)

Co-60 3.602.64E+04 Cs-134 6.334.54E+04 Cs-137 1.50E01E+05 Ni-63 1.314.89E+0807 Sr-90 3.494.50E+0504 5.2.4.

Derived Concentration Guideline Levels for Embedded Pipe 380 The BFM groundwater source term transport and dose assessment pathways applicable to embedded 381 pipe are the same as those assumed for concrete, i.e., the activity in the pipe is released and mixed with 382 the water in the interstitial spaces of the fill material with the water then used for drinking and 383 irrigation. Note that the DCGLs calculated for embedded pipe are based on an assumption of instant 384 release of all activity into the basement fill.

385

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-11 A FSS will be conducted on the interior surfaces of embedded piping to demonstrate that the 386 concentrations of residual radioactivity are equal to or below DCGLs corresponding to the dose 387 criterion in 10 CFR 20.1402 (DCGLEP). DCGLEP were calculated for each of the embedded pipe 388 survey units. The DCGLEP values from LTP Chapter 6, section 6.13 are reproduced in Table 5-7. The 389 IC dose percentages of 10% for Containment and 5% for all other survey units was used to adjust the 390 DCGLEP values in Table 5-7 to account for the dose from the eliminated IC radionuclides.

391 Table 5-7 DCGLs for Embedded Pipe 392 Radionuclide Auxiliary Bldg.

Basement Embedded Floor Drains Turbine Bldg.

Basement Embedded Floor Drains Unit 1 & Unit 2 Containment In-Core Sump Embedded Drain Pipe Unit 1 & Unit 2 Steam Tunnel Embedded Floor Drains Unit 1 & Unit 2 Tendon Tunnel Embedded Floor Drains (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

H-3 N/A N/A 8.28E+09 N/A 1.61E+10 Co-60 7.33E+09 6.31E+09 5.47E+09 4.07E+10 1.06E+10 Ni-63 2.78E+11 1.96E+11 1.40E+11 1.26E+12 2.72E+11 Sr-90 2.41E+08 6.94E+07 4.98E+07 4.48E+08 9.70E+07 Cs-134 5.10E+09 1.43E+09 1.05E+09 9.22E+09 2.04E+09 Cs-137 2.68E+09 1.89E+09 1.37E+09 1.22E+10 2.67E+09 Eu-152 N/A N/A 1.28E+10 N/A 2.48E+10 Eu-154 N/A N/A 1.11E+10 N/A 2.16E+10 5.2.5.

Derived Concentration Guideline Levels for Penetrations 393 A penetration is defined as a pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the 394 pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, 395 and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs 396 through a concrete wall and/or floor and opens to a building on one end and the outside ground on the 397 other end.

398 A penetration survey unit is defined for each basement. The direction that the residual radioactivity 399 may migrate, i.e., into which basement, cannot be predicted with certainty. Therefore, a given 400 penetration that begins in one basement and ends in another will be included in the survey units for both 401 basements. The residual radioactivity in the penetration is assumed to release to both basements 402 simultaneously.

403 The BFM groundwater source term transport and dose assessment pathways applicable to penetrations 404 are the same as those assumed for concrete, i.e., the activity in the penetration is released and mixed 405 with the water in the interstitial spaces of the fill material with the water then used for drinking and 406 irrigation. Note that the DCGLs calculated for penetrations are based on an assumption of instant 407 release of all activity into the basement fill.

408 A FSS will be conducted on the interior surfaces of penetrations to demonstrate that the concentrations 409 of residual radioactivity are equal to or below DCGLs corresponding to the dose criterion in 410 10 CFR 20.1402 (DCGLPN). DCGLPN were calculated for each of the embedded pipe survey units. The 411 DCGLPN values from LTP Chapter 6, section 6.14 are reproduced in Table 5-8. The IC dose 412

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-12 percentages of 10% for Containment and 5% for all other survey units was used to adjust the DCGLPN 413 values in Table 5-8 to account for the dose from the eliminated IC radionuclides.

414 415 416 417 Table 5-8 DCGLs for Penetrations 418 Nuclide Auxiliary Bldg.

Containment SFP/

Transfer Canal Turbine Bldg.

Crib House/

Forebay (1)1 WWTF1 (pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

(pCi/m2)

H-3 3.99E+09 3.42E+09 4.84E+16 3.23E+09 N/A N/A Co-60 8.82E+07 2.26E+09 4.45E+08 1.76E+09 N/A N/A Ni-63 6.79E+10 5.78E+10 1.86E+14 5.48E+10 N/A N/A Sr-90 2.41E+07 2.06E+07 9.26E+10 1.94E+07 N/A N/A Cs-134 3.28E+08 4.32E+08 7.48E+08 4.00E+08 N/A N/A Cs-137 6.17E+08 5.66E+08 1.46E+09 5.29E+08 N/A N/A Eu-152 3.29E+08 5.26E+09 9.44E+08 4.06E+09 N/A N/A Eu-154 2.33E+08 4.58E+09 8.53E+08 3.58E+09 N/A N/A Note (1): The DCGLPN for the Crib House/Forebay and WWTF are listed a not applicable due the very small surface area of the penetrations 419 present. These penetrations are included with the Crib House/Forebay and WWTF surface survey units and the surface DCGLB will 420 apply.

421 5.2.4.5.2.6.

Surrogate Radionuclides 422 The instrumentation and methods used for FRS FSS will be based on the measurement of beta-gamma 423 emitting radionuclides by either gamma spectroscopy or gross counting. The option is available to use 424 gross beta measurements for survey of piping but this approach is not currently planned. Assuming 425 gamma measurements are used for the survey, the concentrations of the HTD radionuclide(s) will be 426 based on known ratio(s) of the HTD radionuclide(s) to beta-gamma radionuclide(s) when demonstrating 427 compliance with the release criteria. This is accomplished through the application of a surrogate 428 relationship. Surrogates may also be developed between beta-gamma emitting radionuclides if gross 429 gamma counting instrumentation is used.

430 As a general rule, surrogate ratio DCGLs are developed and applied to land areas and materials with 431 residual radioactivity where fairly constant radionuclide concentration ratios can be demonstrated to 432 exist. They are in most cases derived using pre-remediation site characterization data collected prior to 433 the FSS or STS. As previously discussed in section 5.1, the radionuclide mixture for Auxiliary 434 Building concrete developed in TSD 14-019 and listed in Table 5-2 are the scaling factors that will be 435 used to determine the surrogate relationship.

436 A surrogate ratio DCGL allows the DCGLs specific to HTD radionuclides in a mixture to be 437 expressed in terms of a single radionuclide that is more readily measured or easy-to-detect (ETD). The 438 ETD or measured radionuclide is called the surrogate radionuclide. Cs-137 is expected to be the 439 principle surrogate radionuclide for the Zion site.

440

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-13 The final ROC for the decommissioning of Zion are Co-60, Cs-134 and Cs-137 (as well as Eu-152 and 441 Eu-154 for Containment), which are gamma emitters and Ni-63, Sr-90 and H-3 (applicable only to 442 Containment), which are HTD radionuclides. During FSS, HTD concentrations will be inferred using a 443 surrogate approach. Cs-137 is the principle surrogate radionuclide for H-3 and Sr-90 and Co-60 is the 444 principle surrogate radionuclide for Ni-63. The mean, maximum and 95% Upper Confidence Level 445 (UCL) of the surrogate ratios for concrete core samples taken in the Containment and Auxiliary 446 Building basements were calculated in TSD 14-019 and are presented in Table 5-9. The maximum 447 ratios will be used in the surrogate calculations during FSS. Note that the 95% UCL is conservatively 448 based in the standard deviation of the individual values as opposed to the standard deviation of the 449 mean.

450 451 Table 5-9 Surrogate Ratios 452 Ratios Containment Auxiliary Building Mean Max 95%UCL Mean Max 95%UCL H-3/Cs-137 0.208 1.760 0.961 N/A N/A N/A Ni-63/Co-60 30.623 442 193.910 44.143 180.450 154.632 Sr-90/Cs-137 0.002 0.021 0.010 0.001 0.002 0.002 Any future continuing characterization or FSS data that contains positive results for H-3, Ni-63 and Sr-453 90 will be reviewed to determine if the ratios exceeds the ratios currently assigned (maximum ratios 454 from Table 5-9). If so, the ratios from the continuing characterization or FSS data will be applied to the 455 FSS surrogate calculations for the given area.

456 Once Using the appropriate scaling factors are determined, the DCGL of the measured radionuclide is 457 modified to account for the represented radionuclide(s) according to the following equation from 458 section 4.3.2 of MARSSIM:

459 Equation 5-1 460 DCGLSUR=DCGLETDx DCGLHTD ConcHTD ConcETD

(DCGLETD)+DCGLHTD 461 where:

462 DCGLSUR = modified DCGL (or Basement Dose Factor) for surrogate ratio, 463 DCGLETD = DCGL for easy-to-detect radionuclide, 464 DCGLHTD = DCGL for the hard-to-detect radionuclide, 465 ConcHTD = Ratio of the HTD or represented radionuclide, and 466 ConcETD = Ratio of the ETD or surrogate radionuclide.

467 5.2.5.5.2.7.

Sum-of-Fractions 468 The SOF or unity rule will is be applied to the data used for the survey planning, and data evaluation 469 and statistical tests for soil sample analyses since multiple radionuclide-specific measurements may be 470 performed or the concentrations inferred based on known relationships. The application of the unity 471 rule serves to normalize the data to allow for an accurate comparison of the various data measurements 472

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-14 to the release criteria. When the unity rule is applied, the DCGLw (used for the nonparametric statistical 473 test) or the Basement Dose Factor becomes one (1). The basement structure DCGLs (DCGLB),

474 embedded pipe DCGLs (DCGLEP) and penetration DCGLs (DCGLPN) are directly analogous to the 475 DCGLW as defined in MARSSIM. The use and application of the unity rule will be performed in 476 accordance with section 4.3.3 of MARSSIM.

477 5.2.6.5.2.8.

Dose from Groundwater 478 Based upon the results of groundwater monitoring performed on the Zion site since June 1998, when 479 both Zion units were placed in a SAFSTOR condition through the current period of active 480 decommissioning, the dose from existing residual radioactivity in groundwater is expected to be 481 diminutive. However, if groundwater contamination is identified during decommissioning, the dose 482 will be calculated using the Groundwater Exposure Factors presented in Chapter 6.

483 5.2.7.5.2.9.

Demonstrating Compliance with Dose Criterion 484 The DCGLs for backfilled basements, surface soil, subsurface soil, buried piping, embedded pipeing 485 and penetrations for each ROC are presented in Tables 5-3, 5-4, 5-5, 5-6, 5-7 and 5-8, respectively. The 486 Basement Dose Factors, soil DCGLs and buried piping DCGLs for each ROC are presented in 487 Tables 5-3, 5-4, 5-5 and 5-6, respectively. These values are equivalent to the level of residual 488 radioactivity in the media (above background) that could, when considered independently for each 489 ROC, result in a TEDE of 25 mrem per year to an AMCG. For the BFM, the total inventory remaining 490 for each ROC will be multiplied by the Basement Dose Factors for each radionuclide to calculate the 491 actual dose from the remaining basement source term. For soilsall media, the dose from the residual 492 radioactivity from each ROC (radionuclide i) can be expressed as shown in the following equation:

493 Equation 5-2 494 DoseMedia= Conc (or Inventory)Radionuclide i DCGLRadionuclide i x 25 mrem/yr 495 After compliance is demonstrated independently through the FSS of each basement, open land area and 496 buried pipe, penetrationthe mean concentrations from the FSS will be used to calculate dose and 497 summed as shown in Equation 5-3. Embedded piping and penetration dose will be added to the dose 498 from wall and floor surfaces in each applicable basement and will be included in the Max Basement 499 term in Equation 5-3. Dose from any elevated areas will be included if applicable. The mean values 500 from FSS will include the results of judgmental samples based on an area-weighted average approach.

501 Detailed instructions for calculating the compliance dose using Equation 5-3 will be provided in a 502 procedure which will be submitted to NRC for information (see LTP Chapter 6, section 6.17 for 503 additional discussion).For the End-State condition of ZNPS, the dose includes contributions from 504 residual radioactivity in soil, existing groundwater, buried pipes and backfilled basements (including 505 embedded piping and penetrations). Demonstrating compliance with the dose criterion requires the 506 summation of dose from these four source terms. The dose will be summed as shown in the following 507 equation.

508 Equation 5-3 509 Compliance Dose

= Max Backfilled Basement + Max Soil + Max Buried Pipe + Max Existing 510 Groundwater 511

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-15 where:

512 Compliance Dose

=

Dose to Resident Farmer AMCG (mrem/yr),

513 Max Backfilled Basement

=

maximum Basement survey unit dose (including 514 embedded pipe, penetrations and elevated areas if EMC 515 test required),

516 Max Soil

=

maximum dose from open land survey units (mrem/yr),

517 Max Buried Pipe

=

maximum dose from buried piping (mrem/yr),

518 Max Existing Groundwater

= maximum dose from existing groundwater 519 520 Complaince Dose = Max BFM + Max Soil + Max Buried + Max GW 521 where:

522 Compliance Dose = Dose to Resident Farmer Critical Group (mrem/yr) 523 Max BFM

= Maximum dose from Basements (mrem/yr), including dose from 524 embedded piping and penetrations 525 Max Soil

= Maximum dose from open land survey units (mrem/yr) 526 Max Buried

= Maximum dose from buried piping (mrem/yr) 527 Max GW

= Maximum dose from radionuclides identified in existing 528 groundwater (none expected) 529 The dose summation described in the equation above is conservative because the various source terms 530 may not in fact be contiguous. For example, the maximum soil survey unit dose may be from an area 531 that is not within the footprint of the Basement with the maximum dose. Another example is the buried 532 pipe that delivers the greatest dose may not be under or contiguous with the soil survey unit with the 533 maximum dose.

534 5.2.8.5.2.10. Soil Area Factors 535 For the decommissioning of ZNPS, Area Factors (AF) apply to soil DCGLs only. Section 2.5.1.1 and 536 section 5.5.2.4 of MARSSIM address the concern of small areas of elevated radioactivity in a survey 537 unit. Rather than using statistical methods, a simple comparison to an investigation level is used to 538 assess the impact of potential elevated areas.

539 Table 5-10 Area Factors for Surface Soils 540 Area (m2)

Area Factors for Radionuclides of Concern Cs-137 Co-60 Cs-134 Ni-63 Sr-90 0.01 1.50E+03 1.23E+03 1.33E+03 3.31E+058.26E+0 5

8.40E+049.60E+0 4

0.03 4.98E+02 4.09E+02 4.42E+02 1.76E+052.75E+0 5

3.03E+043.20E+0 4

0.1 1.50E+02 1.23E+02 1.33E+02 6.92E+048.26E+0 4

8.52E+039.60E+0 3

0.3 4.98E+01 4.09E+01 4.42E+01 2.57E+042.75E+0 2.88E+033.20E+0

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-16 4

3 1

1.50E+01 1.23E+01 1.33E+01 8.06E+03 8.90E+029.57E+0 2

3 6.46E+00 5.24E+00 5.73E+00 2.73E+03 3.13E+023.59E+0 2

10 3.06E+00 2.47E+00 2.72E+00 8.23E+02 1.03E+021.28E+0 2

30 2.10E+00 1.68E+00 1.86E+00 2.75E+02 4.02E+015.13E+0 1

100 1.62E+00 1.29E+00 1.44E+00 8.26E+01 1.64E+011.74E+0 1

300 1.46E+00 1.16E+00 1.30E+00 2.75E+01 6.14E+00 1,000 1.33E+00 1.08E+00 1.20E+00 8.26E+00 1.88E+00 3,000 1.26E+00 1.05E+00 1.16E+00 4.68E+00 1.73E+00 10,000 1.13E+00 1.02E+00 1.08E+00 1.86E+00 1.33E+00 64,500 1.00E+00 1.00E+00 1.00E+00 1.00E+00 1.00E+00 541 542 543

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-17 Table 5-11 Area Factors for Subsurface Soils 544 Area (m2)

Area Factors for Radionuclides of Concern Cs-137 Co-60 Cs-134 Ni-63 Sr-90 0.01 2.04E+03 1.10E+03 1.52E+03 5.16E+05 1.45E+05 0.03 6.80E+02 3.65E+02 5.08E+02 1.98E+05 4.95E+04 0.1 2.04E+02 1.10E+02 1.52E+02 6.30E+04 1.50E+04 0.3 6.80E+01 3.65E+01 5.08E+01 2.14E+04 5.01E+03 1

2.04E+01 1.10E+01 1.52E+01 6.49E+03 1.50E+03 3

9.26E+00 4.91E+00 6.92E+00 2.17E+03 5.23E+02 10 4.48E+00 2.36E+00 3.35E+00 6.51E+02 1.64E+02 30 3.23E+00 1.70E+00 2.42E+00 2.18E+02 5.72E+01 100 2.59E+00 1.37E+00 1.95E+00 6.51E+01 1.76E+01 300 2.29E+00 1.26E+00 1.77E+00 2.17E+01 5.92E+00 1,000 1.90E+00 1.16E+00 1.56E+00 6.53E+00 1.78E+00 3,000 1.72E+00 1.13E+00 1.46E+00 4.12E+00 1.65E+00 10,000 1.32E+00 1.07E+00 1.22E+00 1.81E+00 1.30E+00 64,500 1.00E+00 1.00E+00 1.00E+00 1.00E+00 1.00E+00 The investigation level for this comparison is the DCGLEMC, which is the DCGLw modified by an AF to 545 account for the small area of the elevated radioactivity. The area correction is used because the 546 exposure assumptions are the same as those used to develop the DCGLw. Note that the consideration of 547 small areas of elevated radioactivity applies only to Class 1 survey units, as Class 2 and Class 3 survey 548 units by definition should not have contamination in excess of the DCGLw.

549 The DCGLEMC is also referred to as the required Minimum Detectable Concentration (MDC) for 550 scanning, as shown in Equation 5-3 of MARSSIM. The following equation defines the calculation of a 551 DCGLEMC.

552 Equation 5-4 553 DCGLEMC=AFxDCGLw 554 AFs are calculated using RESRAD for each ROC and for source area sizes ranging from 1 m2 up to the 555 full source area of 64,500 m2. The AFs for surface and subsurface soils were calculated in TSD 14-011 556 and are provided in Tables 5-7 10 and 5-811. The AFs for backfilled basements are discussed in section 557 5.5.3.

558 5.3.

Summary of Characterization Survey Results 559 Chapter 2 provides a description of the radiological status of the site including summary tables and 560 figures that describe the characterization results. The following sections provide assessments of the 561 characterization data to demonstrate the acceptability of the data for use in decommissioning planning, 562 initial area classification, remediation planning, and FRS FSS planning.

563

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-18 5.3.1.

Survey of Impacted Media 564 The characterization of the site commenced in November of 2011 with the characterization of the 565 section of impacted land designed for construction of the future ISFSI facility, the non-impacted 566 location where the Vertical Concrete Cask (VCC) Construction Area was to be located and the pathway 567 for the new rail tracks. Characterization of the impacted and non-impacted open land survey units, as 568 designated by the Zion Historical Site Assessment (HSA) (Reference 5-1313), as well as the 569 structural building basements that would remain and be subjected to FRS FSS was accomplished in the 570 following 23 months with the initial site characterization campaign concluding in October of 2013.

571 During this period, 145,730 m2 of surface soil was scanned, 1,037 surface soil samples were acquired 572 and analyzed, 699 subsurface samples were acquired and analyzed, 282 static measurements were taken 573 on surface soils using a Canberra In Situ Object Counting System (ISOCS), direct scans were 574 performed over approximately 17,700 m2 of basement structures surfaces below the 588 foot elevation, 575 109 concrete core samples were acquired from subsurface basement structuressurfaces, and samples and 576 measurements were taken inside building drain systems.

577 5.3.2.

Field Instrumentation and Sensitivities 578 The field instrumentation for characterization was selected to provide both reliable operation and 579 adequate sensitivity to detect the ROC identified for ZSRP at levels sufficiently below the established 580 action levels. For characterization of soils, the interim screening DCGLs presented in NUREG-1757, 581 Appendix H, Table H.1 and NUREG/CR-5512 Volume 3, Residual Radioactive Contamination from 582 Decommissioning Parameter Analysis, (Reference 5-1414), Table 6.91 (Pcrit = 0.10) were used as the 583 action levels to assess the correct classification of impacted open land or soil survey units. For 584 structures, the nuclide-specific screening value of 7,100 dpm/100cm2 total gross beta-gamma surface 585 activity based on Co-60 from NUREG-1757, Appendix H was used as the action level to evaluate the 586 classification of a structural survey unit. In all cases, the field instruments and detectors selected for 587 static measurements and scanning were capable of detecting the anticipated ROC at a MDC of 50% of 588 the applicable action level.

589 Scanning was performed in order to locate areas of residual activity above the established action levels.

590 Beta scans using hand-held beta scintillation and/or gas-flow proportional detectors (typically 126 cm2) 591 were performed over accessible structural surfaces including, but not limited to; floors, walls, ceilings, 592 roofs, asphalt and concrete paved areas to identify locations for media sampling. Floor monitors using 593 large area gas-flow proportional detectors (typically with 584 cm2) were used to scan the basement floor 594 in the Turbine Building.

595 Gamma scans were performed over open land surfaces to identify locations of residual surface activity.

596 Sodium iodide (NaI) gamma scintillation detectors (typically 2 x 2) were typically used for these 597 scans. ZionSolutions TSD 11-004, Ludlum Model 44-10 Detector Sensitivity (Reference 5-1515) 598 examines the response and scan MDC of the Ludlum Model 44-10 NaI detectors to Co-60 and Cs-137 599 radionuclides when used for scanning surface soils. ISOCS measurements were taken in several open 600 land survey units in lieu of scanning and soil sampling.

601 5.3.3.

Laboratory Instrument Methods and Sensitivities 602 Gamma spectroscopy was primarily performed by the on-site radiological laboratory. Gas proportional 603 counting and liquid scintillation analysis was performed by an approved vendor laboratory in 604

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-19 accordance with approved laboratory procedures. ZSRP ensured that the quality programs of the 605 contracted off-site vendor laboratories that were used for the receipt, preparation and analysis of 606 characterization samples provided the same level of quality as the on-site laboratory under 607 ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS (QAPP) 608 (Reference 5-1616). In all cases, analytical methods were established to ensure that required MDC 609 values are achieved. The analysis of radiological contaminants used standard approved and generally 610 accepted methodologies or other comparable methodologies.

611 5.3.4.

Summary of Survey Results 612 A detailed discussion of the results of site characterization at ZNPS is presented in Chapter 2.

613 5.3.4.1.

Impacted and Non-Impacted Areas 614 The size of the entire ZNPS site is approximately 331 acres. Structures and open land classified as 615 impacted by the operation of the facility are defined by a surrounding single-security fence line that 616 has been designated as the Radiologically Restricted Area. The area defined by the double-security 617 fence line designated as the Security Restricted Area contains all structures and open land areas 618 initially classified as Class 1.

619 In addition to the area within the Radiologically Restricted Area, several additional areas have been 620 deemed as impacted. These include the site parking lot, the open land area directly north of the site 621 and the area along Shiloh Boulevard designated as the West Training Area. The parking lot and the 622 north field were designated as impacted as they represent the major path for material egress on and off 623 of the site. The West Training Area was once the location of the Training Building which housed a 624 Westinghouse Nuclear Training Reactor. The training reactor was decommissioned and the license 625 terminated by the NRC in 1988 and the structure was demolished in 2003.

626 5.3.4.2.

Justification for Non-Impacted Areas 627 MARSSIM defines non-impacted areas as those areas where there is no reasonable possibility of 628 residual contamination. A review of the operating history of the facility, historical incidents, and 629 operational radiological surveys as documented in the HSA was conducted. Based on the review, the 630 open land areas included in the owner-controlled property outside of the footprint of the 87 acre, 631 fence-enclosed Radiologically Restricted Area, minus the additional impacted areas cited in the 632 previous section, were deemed not impacted by licensed activities or materials.

633 From June to September 2013, sufficient survey coverage and an adequate number of samples were 634 obtained in the areas designated as non-impacted to serve as the basis for this classification. Cs-137 635 was the only radionuclide positively identified that could potentially be classified as plant-derived.

636 However, the concentrations observed are well within the range of activity defined as background due 637 to global fallout. The summary of these survey results areis presented in LTP Chapter 2, section 2.3.4.

638 5.3.4.3.

Adequacy of the Characterization 639 The site characterization of ZNPS included the information that should be collected per the guidance in 640 NUREG-1700 and is discussed in detail in Chapter 2. Extensive characterization and monitoring have 641 been performed. Measurements and samples taken in each area, along with the historical information, 642

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-20 provide a clear picture of the residual radioactive materials and its vertical and lateral extent at the site.

643 Using appropriate Data Quality Objectives (DQO), monitoring well water samples, surface water, 644 surface soil, sediment, and sub-surface soil have been collected to provide the profile of residual 645 radioactivity at the site. Samples have been analyzed for the applicable radionuclides with detection 646 limits that provide the level of detail necessary for decommissioning planning. Based upon the volume 647 of characterization data collected and an assessment of the characterization results, ZSRP considers the 648 characterization survey to be adequate to demonstrate that it is unlikely that significant quantities of 649 residual radioactivity have gone undetected.

650 The initial soil (i.e., open land) survey units and survey unit classifications that will be used for the FSS 651 of open land at ZNPS are presented in LTP Chapter 2, section 2.1.6 and Table 2-4. These 652 classifications may be changed to a more restrictive classification as decommissioning progresses.

653 Currently accessible structures that will remain and be subjected to STS FSS have also received 654 characterization sufficient to understand the nature and extent of contamination. The initial survey units 655 and survey unit classifications for structures, both above and below 588 foot elevation that were 656 developed for characterization and decommissioning planning purposes are presented in LTP Chapter 2, 657 section 2.1.6 and Table 2-3. However, the STS FSS that will be applied to structures below 588 foot 658 uses a different design criterion that is not directly driven by the preliminary classifications selected for 659 characterization. ThereforeTherefore, the preliminary survey unit boundaries and classifications will 660 not apply to the STSFSS of structures (basements) below 588 foot.elevation. See section 5.5 for the 661 STS FSS design criteria for basement surface survey unit boundaries and the approach to determining 662 determine survey area coverage.

663 5.3.4.4.

Inaccessible or Not Readily Accessible Areas 664 ZSRP has characterized end-state concrete structures to assess the current residual radioactivity 665 concentration, radionuclide mixture and to ensure the correct classification of each FSS unit. ZSRP has 666 also characterized surface and subsurface soils surrounding ZNPS.

667 The following are areas at Zion where additional or continuing characterization will occur. These 668 areas are; 669

  • The underlying concrete of the SFP/Transfer Canal below the 588 foot elevation after the steel liner 670 has been removed. Continuing characterization will consist of scanning of the exposed concrete 671 surfaces and the acquisition of concrete core sample(s) at the location of highest activity. The 672 number and location of the additional concrete core sample(s) will be determined by DQO during 673 survey design.

674

  • The concrete walls and floor of the Under-Vessel areas in Unit 1 and Unit 2 Containments.

675 Continuing characterization will consist of the acquisition of additional concrete core sample(s).

676 The number and location of the additional concrete core samples will be determined by DQO during 677 survey design.

678

  • The floors and walls of the Hold-Up Tank (HUT) cubicle. Continuing characterization will consist 679 of the acquisition of additional concrete core sample(s). The number and location of the additional 680 concrete core samples will be determined by DQO during survey design.

681

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-21

  • The floor of the Auxiliary Building 542 foot elevation Pipe Tunnel floors. Continuing 682 characterization will consist of the acquisition of additional concrete core sample(s). The number 683 and location of the additional concrete core samples will be determined by DQO during survey 684 design.

685

  • The floor and lower walls of the 542 foot elevation of the Auxiliary Building to augment the 686 existing characterization data. The number and location of the additional concrete core samples will 687 be determined by DQO during survey design.

688

  • The subsurface soils in the keyways between the Containment Buildings and the Turbine Building 689 once subsurface utilities have been removed and the removal of subsurface structures in this area 690 create access (e.g., Waste Annex Building). Continuing characterization will consist of the 691 scanning of soils exposed by the demolition and building removal, the acquisition of soil sample(s) 692 of the exposed soil and the acquisition of additional subsurface soil samples using test pits or soil 693 borings. The number and location of the additional subsurface soil samples will be determined by 694 DQO during survey design.

695

  • The soils under the basement concrete of the Containment Buildings, the Auxiliary Building and the 696 SFP/Transfer Canal once commodity removal and building demolition have progressed to a point 697 where access can be achieved. Continuing characterization will consist of soil borings at the nearest 698 locations along the foundation walls that can be feasibly accessed, angled soil bores to access the 699 soils under the concrete, and deep cores from building floors, but not entirely through the 700 foundation, at bias locations to assess migration potential from building interiors to soils under 701 basement concrete. The number and location of the additional subsurface soil samples will be 702 determined by DQO during survey design. Additional investigations and sampling will be 703 performed in accordance with a sample plan if activity is positively identified.

704

  • When the interior surfaces become accessible, several potentially contaminated embedded and 705 buried pipe systems that will be abandoned in place. Continuing characterization will consist of 706 direct measurements on pipe openings and the acquisition of sediment and/or debris samples (if 707 available) for analysis.

708

  • The Containment basements after concrete removal. Continuing characterization of the steel liner 709 will consist of beta gamma scans and swipe samples.

710 All exposed surface soil at ZNPS has been adequately characterized and additional characterization of 711 surface soil is not anticipated during continuing characterization. Radiological Assessment (RA) 712 surveys will be performed in currently inaccessible soil areas that are exposed after removal of asphalt 713 or concrete roadways and parking lots, rail lines, or building foundation pads (slab inon grade).

714 There are several previously inaccessible soils and buried pipe where historical information, process 715 knowledge or operational survey data indicate that no significant concentrations of residual 716 radioactivity is identified or anticipated and, that the soil or pipe is classified correctly. In these cases, 717 survey design for FSS will be use a coefficient of variation of 30% as a reasonable value for sigma ()

718 in accordance with the guidance in MARSSIM, section 5.5.2.2. All continuing characterization sample 719 plans and results will be provided to NRC for information and continuing characterization results will 720 be provided to the NRC for evaluation.The survey of inaccessible or not readily accessible subsurface 721 soils or surfaces has been deferred. Examples of areas where surveys are deferred include soils under 722 structures, soils under concrete or asphalt coverings, structural wall and floor surfaces below 588 foot 723

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-22 elevation that are obstructed by systems or components, the interiors of embedded and/or buried pipe 724 that may remain and the interior and exterior of both Containment domes. As access is gained to areas 725 that were previously inaccessible, additional characterization data will be collected as necessary, 726 evaluated and stored with-other radiological survey data in a survey history file for the survey unit. In 727 addition, as the decommissioning progresses, data from operational events caused by equipment failures 728 or personnel errors which may affect the radiological status of a survey unit(s) will be captured. These 729 events will be evaluated and, when appropriate, stored in the characterization database. This additional 730 characterization data will be used in validating the initial classification and in planning for the FRS.

731 5.4.

Decommissioning Support Surveys 732 5.4.1.

Radiological Assessment (RA) 733 A Radiological Assessment (RA) is performed to characterize soil in areas that were previously 734 inaccessible and have been exposed due to decommissioning and demolition activities (e.g., removal of 735 slab-on-grade foundations, asphalt parking surfaces and excavations due to buried system removal, 736 installation or reconfiguration.

737 The RA of soil areas will rely principally on direct and scan radiation measurements using gamma 738 sensitive instrumentation described in Table 5-21. In addition to direct and scan radiation 739 measurements, the RA will include the collection of samples of soil, sediment and surface residue for 740 laboratory analysis, as appropriate.

741 5.3.5.5.4.2.

Remedial Action Support (In-Process) Surveys 742 Remedial Action Support Surveys (RASS) are performed while remediation is being conducted, and 743 guides cleanup in a real-time mode. RASS are conducted to: 1) guide remediation activities; 744

2) determine when an area or survey unit has been adequately prepared for the FRSFSS; and, 3) provide 745 updated estimates of the parameters (e.g., variability, and in some instances, a verification of the 746 radionuclide mixture) to be used for planning the FRSFSS.

747 RASS of soil areas will rely principally on direct and scan radiation measurements using gamma 748 sensitive instrumentation described in Table 5-1621. In addition to direct and scan radiation 749 measurements, the RASS will include the collection of samples of soil, sediment and surface residue for 750 laboratory analysis as appropriate.

751 RASS of structural surfaces and systems that will be remediatedundergo remediation, or where there is 752 a potential for residual surface contamination, will be performed using surface contamination monitors, 753 augmented with sampling for removable surface contamination. RASS surveys may also be performed 754 using the ISOCS, especially where personnel safety is of concern. Examples include: overhead 755 ceilings, upper walls and cavity locations where the use of scaffolding and areal lifts is impractical.

756 5.3.6.5.4.3.

Description of Field Screening Methods and Instrumentation for RA and RASS 757 Table 5-14 21 shows typical field instruments that will be used for performing FRSFSS. The same or 758 similar instruments will be used during the performance of the RA and RASS. The typical MDCs for 759 field instruments used for scanning are provided in Table 5-15 22 and are sufficient to measure 760 concentrations at the same action levels used during characterization as specified in section 5.3.2.

761

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-23 Analytical capability for soil sample analysis will supplement field scanning techniques to provide 762 radionuclide-specific quantification, achieve lower MDCs, and provide timely analytical results. The 763 on-site laboratory will include a gamma spectroscopy system calibrated for various sample geometries.

764 The system will be calibrated using mixed gamma standards traceable to the National Institute of 765 Standards and Technology (NIST) and intrinsic calibration routines. Count times will be established 766 such that the DQOs for MDC will be achieved. Gas proportional counting and liquid scintillation 767 analysis will be performed by an approved vendor laboratory in accordance with approved laboratory 768 procedures. ZSRP will ensure that the quality programs of any contracted off-site vendor laboratory 769 that is used for the receipt, preparation and analysis of RA and RASS samples will provide the same 770 level of quality as the on-site laboratory under the QAPP.

771 5.3.7.5.4.4.

Field Screening Methods for RA and RASS During the Excavation of Soils 772 A gamma walk-over survey will be performed over the excavated surface area, typically using a 2 inch 773 by 2 inch NaI gamma scintillation detector. Appropriate scanning speed and scanning distance will be 774 implemented to ensure that a MDC of 50% of the applicable DCGLsurface soil DCGLs (Table 5-4) is 775 achieved. Locations of elevated count rate will be identified for additional scanning and/or the 776 collection of biased soil samples to determine if the elevated count rate indicates the presence of soil 777 concentration in excess of the surface soil DCGLs (Table 5-4)applicable DCGL. The information 778 obtained during the RA and RASS (scan results and the analytical data from any associated soil 779 samples) will be used to determine if the remaining exposed soils:

780

  • contain radioactivity concentrations above the surface soil DCGLs (Table 5-4)applicable DCGL and 781 require further excavation; 782
  • contain radioactivity concentrations that are less than the surface soil DCGLs (Table 5-4)applicable 783 DCGL, but require removal in order to access additional soil/debris that potentially contains 784 radioactivity concentrations above the applicable DCGL; or, 785
  • contain radioactivity concentrations that are less than the surface soil DCGLs (Table 5-4)applicable 786 DCGL, and not requiring removal.

787 ZionSolutions TSD 11-004 examines the response and scan MDC of the Ludlum Model 44-10 NaI 788 detectors to Co-60 and Cs-137 radionuclides when used for scanning surface soils. If the survey 789 instrument scan MDC is less than the surface soil DCGLs (Table 5-4)applicable DCGL, then scanning 790 will be the primary method for guiding the remediationdetermining if the area is suitable for FSS. Once 791 the scan surveys and the laboratory data obtained from any biased soil samples that may have been 792 collected indicate residual concentrations are less than the surface soil DCGLs (Table 5-4)applicable 793 DCGL, the area will be considered suitable for FSS.

794 When supporting soil remediation, iIf the scan MDC is greater than the soil DCGLw, the gamma walk-795 over survey will still be used to initially guide remediation however, as the levels are reduced to the 796 range of the DCGLw an additional number of biased soil samples may be required to ensure the area can 797 be released as suitable for FSS.

798 The Canberra ISOCS system may be used in lieu of the walk over survey using a NaI detector provided 799 the scan sensitivity meets the field screening requirements.

800 5.3.8.5.4.5.

Contamination Verification Surveys (CVS) of Basement Structural SurfacesField 801

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-24 Screening Methods for RASS of Below-Grade Structural Surfaces 802 All remaining structural surfaces will be surveyed to meet the criteria for open air demolition specified 803 in ZionSolutions TSD 10-002, Technical Basis for Radiological Limits for Structure/Building Open 804 Air Demolition (Reference 5-17). These criterions are the acceptable removable contamination and 805 contact exposure rate levels that are allowable for open air demolition. A contamination verification 806 survey (CVS) will be performed to identify areas requiring remediation to meet the open air demolition 807 limits. A CVS will be performed within any structure that contains, or previously contained, 808 radiological controlled areas. The CVS will be performed using hand-held beta-gamma instrumentation 809 as presented in Table 5-1621 in typical scanning and measurement modes.

810 The CVS will include extensive scan surveys on the structural surfaces (walls, floors and miscellaneous 811 equipment) that will be subject to open air demolition, regardless of elevation. The scan coverage is 812 dependent on the contamination potential of the structural surface being surveyed. Class 1 survey units 813 will require 100% scan coverage of all accessibleexposed concrete surface areas. Any areas identified 814 in excess of the open air demolition limits will be remediated.

815 For structural surfaces below the 588 foot elevation that will remain and be subject to a FSS (primarily 816 any basement floor and outer walls), additional remediation will be performed prior to demolition to 817 ensure that any individual ISOCS measurement will not exceed the DCGLB from Table 5-33 during 818 FSS. Any areas identified that have the potential to exceed the DCGLB by ISOCS measurement during 819 the performance of CVS in these areas will be earmarked for remediation. and Any areas of elevated 820 activity that could potentially approach the DCGLB will be identified as a location for a judgmental 821 ISOCS measurement during FSS. The CVS will be performed using hand-held beta-gamma 822 instrumentation as presented in Table 5-16 in typical scanning and measurement modes. The CVS will 823 include extensive scan surveys on the structural surfaces (walls and floors) located below the 588 foot 824 elevation that will remain. The scan coverage is dependent on the contamination potential of the 825 structural surface being surveyed. Class 1 survey units will require 100% scan coverage of all 826 accessible surface area.For the CVS of Class 2 basement structural surfaces, it is not expected that scan 827 measurements will indicate the presence of residual radioactivity exceeding the DCGLB values in Table 828 5-3. Any areas of elevated activity identified by the CVS that could potentially approach the DCGLB 829 will be identified as a location for a judgmental measurement during FSS.All remaining structural 830 surfaces will be remediated to the criteria specified in ZionSolutions TSD 10-002, Technical Basis 831 for Radiological Limits for Structure/Building Open Air Demolition (Reference 5-17). These 832 conditions or indicators are designations used to characterize the acceptable removable contamination 833 and contact exposure rate levels that are allowable for open air demolition. This approach calculates the 834 acceptable levels of fixed and removable contamination based upon re-suspension factors and 835 ground level release and dispersion models. The limits are based upon the calculated member of the 836 public dose at the site boundary using Off Site Dose Calculation Manual (ODCM) methodologies for a 837 ground level airborne radioactivity release.

838 Based upon the calculations, comparisons, and conclusions documented in TSD 10-002, the following 839 open air demolition limits will be implemented:

840 Less than 2 mR/hr beta-gamma total surface contamination on contact with structural surface.

841 Less than 1,000 dpm/100cm2 beta-gamma loose surface contamination.

842

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-25 All structural surfaces will be remediated to the open air demolition limits prior to structural demolition.

843 Confirmatory radiological surveys will be performed using approved procedures following remediation 844 and prior to demolition to ensure that contamination levels are acceptable. The radiological surveys 845 will include extensive surveys on the structural surfaces (walls and floors) located below the 588 foot 846 elevation that will remain. These surveys will be performed using conventional gamma instruments in 847 typical scanning and measurement modes. Scanning coverage for pre-remediation surveys on structures 848 prior to open air demolition could include up to 100% of the accessible surface area depending on the 849 contamination potential. Consequently, the pre-remediation surveys performed to prepare building 850 surfaces for open air demolition will provide confidence that structural surfaces that have significant 851 elevated activity will be removed. Once remediation is complete, structural surfaces located above the 852 588 foot elevation and non-load-bearing interior concrete walls below the 588 foot elevation that 853 contain detectable residual radioactivity will be demolished, reduced in size, packaged and shipped off-854 site to a licensed disposal facility.

855 5.4.6.

Post-Demolition Survey 856 Following demolition, after all debris is removed and the floors cleaned, an additional scan survey will 857 be performed on 100% of the Class 1 basement floors that will be subject to FSS, again using hand-held 858 beta-gamma instrumentation as presented in Table 5-21 in typical scanning and measurement modes.

859 Any identified elevated areas that could potentially exceed the DCGLB will be identified and bounded.

860 A concrete core sample will be collected at the location that exhibits the highest activity within any 861 bounded area. If the activity in the core (summing activity in all core slices) exceeds the DCGLB values 862 in Table 5-3, an EMC test will be performed (see section 5.5.3).

863 5.4.5.5.Final Status Survey of Basement StructuresSource Term Survey (STS) 864 Basement structures are defined as basement (concrete) surfaces (concrete and steel liner), embedded 865 pipe, and penetrations. As described in section 5.4.5, all remaining floor and wall concrete surfaces will 866 be remediated to levels below the DCGLB as measured by ISOCS during FSS. After When a basement 867 surface has been successfully remediationed, a FSS will be conducted to demonstrate that the residual 868 radioactivity in building basements corresponds to a dose below the 25 mrem/yr criteria.

869 As described in section 5.4.3, all remaining floor and wall concrete surfaces will be remediated to levels 870 that will allow demolition of above ground structures in open air with minimum contamination controls.

871 This criterion, presented in ZionSolutions TSD 10-002, provides an upper bound on the residual 872 radioactivity concentration that would remain in concrete at license termination. This is an important 873 consideration in the evaluation of the potential risk from non-uniform distributions to affect the mean 874 inventory value calculated from STS measurements. This criterion does not include any additional 875 remediation that may be required to meet the 25 mrem/yr license termination criteria in accordance with 876 10 CFR 20 Subpart E.

877 When a basement structure has been successfully remediated to the open air demolition criterion, a STS 878 will be conducted to demonstrate that the inventory of residual radioactivity in building basements, 879 embedded piping and penetrations is below the 25 mrem/yr dose criterion by multiplying the remaining 880 inventory by the Basement Dose Factors. The actual mean inventory determined by performing the 881 STS is used as the source term in the BFM to determine the dose to the AMCG.

882

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-26 Several aspects of the BFM conceptual model and source term requirements are different from the 883 assumptions intrinsic to a typical FSS survey design. These differences are:

884 The BFM source term is the total inventory (mCi) in all walls and floor of each building as opposed to a 885 concentration based DCGLw (pCi/g or dpm/100cm2) that can be represented by a single measurement.

886 The BFM is a mixing model with a source term based on total inventory that is independent of 887 concentration levels and areal distribution of residual radioactivity. Therefore, the typical scan 888 coverage guidance as presented in MARSSIM, which relies on concentration based DCGLW and 889 DCGLEMC values, is not directly applicable.

890 The standard approach in MARSSIM for calculating AFs in conjunction with DCGLW values to 891 determine the acceptability of elevated areas of activity does not apply to the BFM inventory source 892 term which is independent of concentration levels and areal distribution.

893 The application of statistical testing to determine compliance on a survey unit basis does not directly 894 apply to the BFM inventory source term if more than one survey unit is contained in a given building.

895 In this case, the inventories of the survey units are additive, which requires a slight adjustment to the 896 approach specified in MARSSIM to survey design and assessment.

897 The DQO process was used to determine the most effective process for designing the STS, given the 898 differences between the BFM Inventory Source Term and the DCGL approach specified in MARSSIM.

899 However, the concept of a graded survey approach based upon the contamination potential, as well as 900 the conceptual processes for survey design and data assessment from MARSSIM have been retained.

901 5.4.1.5.5.1.

Instruments Selected for Performing STSFSS of Basement Surfaces 902 The Canberra ISOCS has been selected as the primary instrument that will be used to perform FSS of 903 basement surfaces. Direct beta measurements taken on the concrete surface will not provide the data 904 necessary to determine the residual radioactivity at depth in concrete and therefore, would have to be 905 augmented with core sampling. The ISOCS was selected as the instrument of choice to perform FSS of 906 basement structures surfaces for the following reasons:

907 The surface area covered by a single ISOCS measurement is large (a nominal range of 10-30 m2) 908 which essentially eliminates the need for scan surveys.

909 Access for ISOCS measurements can be more readily accomplished remotely and does not require 910 extensive and prolonged contact with structural surfaces that would be necessary to perform scan 911 surveys using beta instrumentation.

912 ISOCS measurements will provide results that can be used directly to determine total activity with 913 depth in concrete.

914 One of the most significant advantages of the ISOCS system in the FSS application is the that 915 analytical capability to perform comprehensive uncertainty analysis of various potential source 916 term geometries (depth and areal distribution). after an ISOCS measurement is collected, it can be 917 tested against a variety of geometry assumptions to address uncertainty in the source term 918 geometry if necessary. This uncertainty analysis could potentially be used to generate a 919

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-27 conservative result using an efficiency based on a clearly conservative geometry to resolve 920 questions without additional core samples measurements.

921 Additional concrete core sampling will be taken as continuing characterization in the SFP/Transfer 922 Canal, HUT cubicles and Auxiliary Building 542 foot elevation Pipe Tunnels to confirm the depth 923 distribution of activity in concrete in support of ISOCS geometry assumptions and sensitivity analysis.

924 The All additional concrete cores samples taken during continuing characterization will be evaluated to 925 ensure that the ISOCS geometry used for efficiency calculations is sufficiently conservative. during 926 FSS 927 During the survey design for STS, the DQO process will be used to determine the most limiting 928 geometry for the ISOCS measurements based on the physical conditions of the remediated surface and 929 the depth and distribution of activity in the concrete surface as identified by existing characterization 930 data and surveys taken during structure remediation. Note that the Auxiliary Building 542 foot 931 elevation floor (and possibly the remaining concrete of the SFP/Transfer Canal, which has not yet been 932 surveyed) is the only structural surface that will remain in the end-state where excessive variability in 933 the geometry of residual radioactivity has been detected at depth. These are the only two STS survey 934 units where concrete core sampling and/or scan surveys may also be used to confirm the areal and depth 935 distribution of activity in concrete in support of ISOCS geometry assumptions and sensitivity analysis.

936 In these two STS survey units, a determination will be made during survey design to ascertain if the 937 ISOCS geometry is sufficiently conservative to capture the variability of residual radioactivity at depth 938 and if additional concrete core samples are necessary to confirm the depth profile.

939 5.4.2.5.5.2.

Basement Surface FSS UnitsSTS Survey Units 940 The FSS of basement surfaces will be performed in accordance with approved procedures and in 941 compliance with FSS quality requirements in the QAPP.

942 STS will be designed and documented in the same manner as a traditional FSS and performed in 943 accordance with approved procedures and in compliance with FSS quality requirements in the QAPP.

944 The BFM is not sensitive to the concentration or areal distribution of residual radioactivity. Therefore, 945 there is no intrinsic survey unit size limitation for the basement structures analogous to MARSSIM 946 recommended survey unit sizes, which are based on a building occupancy scenario.

947 The survey units designated for structures below 588 foot elevation from the HSA that were presented 948 in LTP Chapter 2, Table 2-23 were based on screening values and source term assumptions that are 949 significantly different from the BFM and are therefore not applicable.

950 With the exception of the Auxiliary Building, where the walls and floor will be separate survey units, 951 tThe STS FSS survey units will be comprised of the combined wall and floor surfaces of each 952 remaining building basement, i.e., Auxiliary Building, Unit 1 Containment, Unit 2 Containment, 953 Turbine Building, Crib House/Forebay, WWTF and remnants of the SFP/Fuel Transfer Canal. The 954 Containment Buildings will contain two surface survey units, the walls and floors of the exposed steel 955 liner and the under-vessel area where concrete will remain (see section 5.5.2.1).

956 The activity in the Circulating Water Intake Pipes, and Circulating Water Discharge Tunnels, 957 Circulating Water Discharge Pipes, and Buttress Pits/Tendon Tunnels is included with Turbine Building 958 through the DCGL calculation. The activity in the Circulating Water Intake Pipe is also included with 959 the Crib House/Forebay through the DCGL calculation. See LTP Revision 1 Chapter 6, section 6.6.8 960

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-28 for discussion of the DCGL calculations. The Circulating Water Discharge Tunnels Discharge Tunnel 961 will be addressed as a separate survey unit within the Turbine Building. Access to the Circulating 962 Water Intake Pipes, Discharge Pipes, and Buttress Pits/Tendon Tunnels isare very limited and therefore, 963 these areas swill be surveyed as biased areas using judgmental samples. The judgmental sample results 964 will be added to the mean of the Turbine Building and Crib House/Forebay FSS survey unit results.

965 The entire surface areas will be included in the area-weighted average calculation. (see section 5.5.7.1).

966 Contamination potential was the prime consideration for grouping STS FSS survey units. Contiguous 967 surface areas with the same contamination potential will minimize uncertainty in the estimate of the 968 mean concentration inventory and ensure the appropriate level of areal coverage. Characterization data, 969 radiological surveys performed to support commodity removal and surveys performed to support 970 structural remediation for open air demolition have and will continue to be used to verify that the 971 contamination potential within each STS FSS survey unit is reasonably uniform throughout all walls 972 and floor surfaces. The FSS of Class 1 survey units include ISOCS measurements over 100% of wall 973 and floors surfaces, eliminating uncertainty in the assumptions regarding uniformity of the underlying 974 population.

975 5.4.2.1.5.5.2.1.

Classification and Areal Coverage for FSS of Basement SurfacesSTS Areal 976 Coverage 977 The primary consideration for determining FSS classification and areal coverage in basement surfaces 978 is the potential for an individual measurement in a FSS unit to exceed the dose criterion. This is 979 evaluated by the potential for an individual ISOCS measurement to exceed the DCGLB.

980 As discussed in section 5.4.5, extensive surface scan surveys, in some cases 100% of the surface area, 981 will be performed during CVS. In addition to the CVS, information on contamination potential is also 982 provided by characterization surveys performed to date and radiological surveys to be performed to 983 support commodity removal. All of this information has been and will continue to be used to and 984 validate survey unit classification.

985 Above the 565 foot elevation, all concrete will be removed from each of the Containment basements to 986 expose the steel liner. As a consequence, the entire source term above the 565 foot elevation will be 987 removed as well. After all of the concrete above the 565 foot elevation is removed, it is anticipated that 988 the residual radioactivity remaining in the Containment basement surfaces (comprised of steel liner 989 only) above the 565 foot elevation will correspond to a small fraction of the dose criterion. if requested 990 The FSS units for the Auxiliary Building 542 foot elevation floor and walls, the concrete (and any 991 exposed liner) in both Containment Under-Vessel areas and the remaining SFP/Transfer Canal 992 structural surfaces are designated as Class 1 and the FSS areal coverage will be 100% which is 993 consistent with MARSSIM, Table 5.9. For the remaining basement surface FSS units (the Containment 994 basements including the 565 foot elevation liner and above, the Turbine Building basement, the Crib 995 House/Forebay, Circulating Water Discharge Tunnels and the WWTF), the criteria for selecting 996 reasonable and risk-informed ISOCS areal coverage will be based on the MARSSIM, Table 5.9 scan 997 survey guidance for Class 2 and Class 3 structures. The criteria for selecting areal coverage is based on 998 a graded approach consistent with the guidance for scan surveys for FSS in MARSSIM section 2.2.

999 For the purpose of STS design, the Basement Dose Factors were used to calculate a hypothetical 1000 maximum inventory level the ROC in each basement as listed in Table 5-9. These calculated values, 1001 which are designated as Basement Inventory Levels (BIL), do not represent the inventory levels 1002

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-29 expected to remain at license termination. The actual mean inventory determined by performing the 1003 STS will be used as the source term in the BFM to determine the dose to the AMCG. As described 1004 below, the actual inventory expected to remain in the basements is a small fraction of the BIL.

1005 The BIL is used during STS survey design to determine a reasonable areal coverage based upon the 1006 theoretical potential of exceeding the inventory level based upon characterization survey data.

1007 The primary consideration for determining STS areal coverage is the potential for the presence of a 1008 residual radioactivity inventory in a STS survey unit that could exceed the BIL. Survey areal coverage 1009 can be a low percentage of the total wall and floor surface area in survey units that have a low potential 1010 for exceeding the BIL. Conversely, in areas with a high potential for approaching the BIL, a higher 1011 percentage of coverage is justified.

1012 A secondary consideration is the potential for the presence of small areas of elevated radioactivity in a 1013 STS survey unit that could exceed the BIL. The areal coverage of the STS should be commensurate 1014 with the probability that a small area of elevated radioactivity could exist within a STS survey unit in a 1015 concentration exceeding the BIL and the likelihood that such an area would be detected by the STS 1016 ISOCS measurements. As discussed in section 5.4.3, extensive surface scan surveys, in some cases 1017 100% of the surface area, will be performed to identify areas exceeding the open air demolition criteria 1018 Table 5-9 Basement Inventory Levels (BIL) Used for STS Design (mCi Total Inventory) 1019 Nuclide Auxiliary (mCi)

Containment (mCi)

Fuel (mCi)

Turbine (mCi)

Crib House/Forebay (mCi)

WWTF (mCi)

Co-60 2.28E+03 6.05E+02 2.08E+01 1.98E+03 1.22E+03 3.30E+01 Cs-134 1.59E+03 1.16E+02 3.50E+01 4.50E+02 4.71E+02 2.70E+00 Cs-137 8.35E+02 1.52E+02 6.82E+01 5.94E+02 6.52E+02 3.42E+00 Eu-152 4.86E+03 1.41E+03 4.42E+01 4.56E+03 2.72E+03 8.82E+01 Eu-154 4.38E+03 1.23E+03 3.99E+01 4.03E+03 2.48E+03 6.71E+01 H-3 3.98E+03 9.16E+02 2.27E+09 3.63E+03 4.26E+03 2.00E+01 Ni-63 8.64E+04 1.55E+04 8.77E+06 6.16E+04 7.18E+04 3.38E+02 Sr-90 7.50E+01 5.51E+00 4.64E+03 2.18E+01 2.56E+01 1.20E-01 prior to remediation. The scanning performed during the RASS or radiological survey during 1020 remediation is integral to the STS survey planning process and will provide a high degree of confidence 1021 that areas with contamination exceeding the open air demolition criteria will be identified and 1022 remediated.

1023 It is highly unlikely that an area with the hypothetical maximum concentration of residual radioactivity 1024 that could remain after remediation to the 2 mR/hr open air demolition criteria could approach the BIL 1025 and not be detected by the STS ISOCS measurements. Note that the Auxiliary Building 542 foot 1026 elevation floor and possibly the remaining concrete of the SFP/Transfer Canal are the only areas where 1027 contamination above the 2 mR/hr criteria is expected to be present. All contaminated concrete will be 1028

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-30 removed from both Containment basements during and characterization surveys have already shown 1029 that the residual radioactivity source term in the remaining basement structures after all concrete is 1030 removed is minimal. A simple, nominal calculation demonstrates this point. The worst case 1031 concentration and depth profile identified during biased characterization sampling was in a core sample 1032 collected in the 2A RHR Pump room on the 542 foot elevation of the Auxiliary Building. After 1033 remediation to the 2 mR/hr open air demolition criteria, this area could hypothetically have an average 1034 Cs-137 concentration of 4,255 pCi/g over a three inch depth of concrete. At this inventory level, the 1035 contaminated area would need to be approximately 350 m2 in area before it would exceed the BIL for 1036 Cs-137. The corresponding inventory in elevated areas of 1 m2 and 10 m2 size at this concentration of 1037 Cs-137 would be 0.3% and 3% of the BIL, respectively.

1038 It is highly unlikely that the ISOCS, with a nominal Field-of-View (FOV) of 28 m2 would not detect 1039 and account for elevated areas in the geometries discussed above, assuming a reasonable areal coverage.

1040 In addition, given the information on contamination potential provided by characterization surveys 1041 performed to date, coupled with the survey information that will be provided by RASS supporting 1042 commodity removal, RASS performed to demonstrate that structural surfaces meet the open air 1043 demolition criteria specified in TSD 10-002 and RASS performed to demonstrate the adequacy of any 1044 remediation performed, there is a high degree of confidence that any area with elevated activity that 1045 could possibly exceed the BIL will be identified. However, to provide a higher degree of confidence 1046 that all potential areas with elevated activity will be accounted for in the total inventory estimate, 100%

1047 areal coverage will be required in all STS survey units that will require remediation to meet the open air 1048 demolition criteria specified in TSD 10-002. As stated above, this is expected to apply only to the 1049 Auxiliary Building 542 foot elevation floor and the remaining concrete of the SFP/Transfer Canal after 1050 the liner is removed. These two STS survey units are classified analogous to a Class 1 as defined in 1051 MARSSIM, section 2.2 and the areal coverage from MARSSIM, Table 5.9 that corresponds to that 1052 classification.

1053 For the remaining STS survey units (the walls of the Auxiliary Building basement, Unit 1 Containment 1054 basement, Unit 2 Containment basement, Turbine Building basement, the basement of the Crib House 1055 and the Forebay, the remnants of the WWTF and the Circulating Water Intake and Circulating Water 1056 Discharge Tunnels), the criteria for selecting reasonable and risk-informed areal coverage will be based 1057 on a graded approach similar to the MARSSIM, Table 5.9 scan survey guidance for Class 2 and Class 3 1058 structures. Because elevated areas will be well known and identified, the primary basis for determining 1059 the areal coverage for the STS ISOCS measurements is the potential for the total BIL to be exceeded in 1060 the survey unit. The criteria for selecting reasonable and risk-informed areal coverage are based on a 1061 graded approach similar to the guidance for scan surveys for FSS in MARSSIM section 2.2. However, 1062 instead of basing the coverage on the expected fraction of the DCGL, the coverage will be based on the 1063 expected fraction of the BIL.

1064 5.4.2.1.1.5.5.2.1.1.

FSS Units for the Containment BasementsSTS Survey Units for Auxiliary 1065 Building Basement Walls and Containment Basements 1066 ZionSolutions TSD 14-013, Zion Auxiliary Building End State Estimated Concrete Volumes, Surface 1067 Areas, and Source Terms (Reference 5-18) examines the source term estimates based upon concrete 1068 cores collected from the 542 foot elevation concrete floor and walls. During characterization, concrete 1069 core samples were collected at locations exhibiting the highest contact dose rate. TSD 14-013 provides 1070

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-31 a conservative bounding estimate of the initial source term in the Auxiliary Building basement walls 1071 and floors to aid in evaluating the potential dose consequences.

1072 In accordance with TSD 14-013, a conservative bounding estimate of 0.15 Ci of Cs-137 was derived for 1073 the walls of the Auxiliary Building basement based upon the analysis of the biased concrete core 1074 samples. This bounding estimate is approximately 18% of the BIL for Cs-137 in the Auxiliary Building 1075 as presented in Table 5-9. The inventory estimate assumed a concrete contamination depth of 1/2 inch, 1076 however the analysis of the concrete cores shows that the average depth of contamination is less.

1077 Consequently, the source term estimate calculated for the walls is a very conservative estimate that is 1078 probably greater than the actual activity embedded in the walls.

1079 In both Containment basements, all concrete above the 54165 foot elevation will be removed to expose 1080 the steel liner. As a consequence, the entire source term in the Containments above the 565 foot 1081 elevation associated with the Containments will be removed as well. Below the 565 foot elevation, the 1082 concrete in the Under-Vessel areas of both Containments will remain, primarily due to safety concerns 1083 associated with removing the concrete. Previous characterization surveys indicate that the concrete in 1084 the Under-Vessel areas are volumetrically contaminated due to activation at levels below the DCGLB 1085 values in Table 5-43 but contain surface contamination that exceeds the DCGLB. Consequently, the 1086 concrete in both Under-Vessel areas have been designated as Class 1. As discussed in section 5.3.4.4, 1087 additional samples will be taken in the Under-Vessel areas as part of continuing characterization.

1088 Due to the fact that all of the contaminated concrete above the 565 foot elevation steel liner will be 1089 completely removed in each Containment, the typical approach of classifying an areathe 1090 Containment(s) above the 565 foot elevation based on pre-remediation levels is not applicable. The 1091 guidance in MARSSIM would apply if the concrete were scabbled or shaved, leaving the majority of 1092 the concrete intact. This is not the case for the Containments above the 565 foot elevation, where all of 1093 the media will be removed, not simply the contaminated portion. The only residual radioactivity that 1094 could remain in the end state Containments above the 565 foot elevation end-state is contaminated 1095 concrete dust remaining on the steel liner from the demolition process. Additionally, it is anticipated 1096 that prior to turning over the Containment buildings for STSFSS, the building basements will be 1097 decontaminated to remove loose surface contamination, minimizing the potential for remaining 1098 contaminated concrete dust. Once remediation is complete, the fraction of the DCGLB in the 1099 Containment basement(s) liner on the 565 foot elevation floor, and walls above the 565 foot elevation, 1100 from any remaining source term is expected to be small. As per the definition of a Class 2 area from 1101 MARSSIM, section 2.2, it becomes an area that had, prior to remediation, a potential for 1102 radioactive/contamination or known contamination, but is not expected to exceed the release criteria.

1103 Continuing characterization will be performed in each Containment basement on the 565 foot elevation 1104 floorsteel liner floor and walls above above the 565 foot elevation after concrete removal to confirm the 1105 assumption that minimal residual radioactivity will remain. All continuing characterization sample 1106 plans will be provided to the NRC for information and results will be provided to NRC for evaluation. if 1107 requested 1108 The FSS units for of the 565 foot elevation steel liner floor foor and walls above the 565 foot elevation 1109 floor in the Containment basements at the 565 foot elevation floor and are classified analogous to 1110 Class 2 as defined in MARSSIM, section 2.2. While the definition of a Class 2 area refers to the 1111 potential for exceeding the release criteria, the potential for the concentrations of residual radioactivity 1112 in the Containment basement(s) above the 565 foot elevation to exceed the DCGLB as presented in 1113

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-32 Table 5-3 is very low due to complete removal of the contaminated media (i.e., concrete). As a 1114 conservative measure, these FSS units will be subjected to an areal coverage commensurate with the 1115 guidance pertaining to Class 2 scan coverage as presented in MARSSIM, Table 5-1.9. Sufficient 1116 ISOCS measurements will be taken to ensure that at least 10% of the surface area in each survey unit is 1117 subjected to FSS. In addition to the prescribed areal coverage, additional judgmental measurements 1118 may be collected at locations with higher potential for containing elevated concentrations of residual 1119 radioactivity based on characterization, the results of CVS or professional judgment.The STS survey 1120 units for the walls of the Auxiliary Building and the two Containment basements are classified 1121 analogous to Class 2 as defined in MARSSIM, section 2.2. While the definition of a Class 2 area refers 1122 to the potential for exceeding the release criteria, the potential for the residual radioactivity inventory in 1123 the walls of the Auxiliary Building basement or the Containment basements exceeding the BILs as 1124 presented in Table 5-9 is highly unlikely. As a conservative measure, these three STS survey units will 1125 be subjected to an areal coverage commensurate with the guidance pertaining to Class 2 scan coverage 1126 as presented in MARSSIM, Table 5.9. Sufficient ISOCS measurements will be taken to ensure that at 1127 least 10% of the surface area in each survey unit is subjected to STS survey.

1128 5.4.2.1.2.5.5.2.1.2.

STS FSS Survey Units for Turbine Building Basement, Crib House/Forebay, 1129 WWTF and Circulating Water Intake and Discharge Tunnels 1130 Extensive characterization has been performed in the 560 foot and 570 foot elevations of the Turbine 1131 Building and in the Crib House. A series of concrete core samples were taken in all three locations. In 1132 addition, the entire floor of the Turbine Building 560 foot elevation was scanned using a Ludlum 1133 Model 43-37 floor monitor. The maximum radiological concentration observed in the analysis of all 1134 the concrete core samples taken in the Turbine Building basement or Crib House was 46.70 pCi/g. The 1135 scan of the Turbine Building 560 foot elevation resulted in a maximum observed count rate of 1136 3,922 cpm/100 cm2.

1137 At the time of LTP submittal, the Forebay and the Circulating Water Intake Piping and Discharge 1138 Tunnels are were completely underwater and not accessible. In addition, the portion of the WWTF 1139 located below the 588 foot elevation that will remain is was also not currently accessible.

1140 Consequently, no characterization has been performed to date in these STS survey units. However, 1141 pProcess knowledge and the results of environmental monitoring of radiological conditions at effluent 1142 outfalls in the past indicates that the probability of that any residual radioactivity inventory in these STS 1143 FSS survey units will exceeding 50% of the DCGLB as presented in Table 5-3 is very lowhighly 1144 unlikely.is a minute fraction of the BILs presented in Table 5-9.

1145 The STS FSS survey units for the basements of the Turbine Building, the Crib House/Forebay, WWTF 1146 and the Circulating Water Intake and Discharge Tunnels are designated as classified analogous to 1147 Class 3 as defined in MARSSIM, section 2.2 in that the STS FSS survey units are not expected to 1148 contain any residual radioactivity, or are expected to contain levels of residual radioactivity at a small 1149 fraction of the BILs DCGLs presented in Table 5-35-9, based on site operating history and previous 1150 radiation surveys. These four STS FSS survey units will be subjected to an areal coverage 1151 commensurate with the guidance pertaining to Class 3 scan coverage as presented in MARSSIM, 1152 Table 5.9, which states that the scan coverage guidance is judgmental. In this context, judgmental 1153 areal coverage will be defined as sufficient ISOCS measurements to ensure that at least 1% of the 1154 surface area in each survey unit is subjected to STS FSSsurvey.

1155

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-33 5.4.2.2.5.5.2.2.

Sample Size Determination for FSS of Basement SurfacesSTS Sample Size 1156 Determination 1157 Based on the contamination potential of each STS FSS survey unit that was determined in the previous 1158 section, along with the corresponding areal coverage, the number of ISOCS measurements required in 1159 each STS FSS survey unit can be calculated as the quotient of the ISOCS FOV divided into the surface 1160 area required for areal coverage. Table 5-10 12 presents the STS FSS survey units, the classification 1161 based on contamination potential, the surface area to be surveyed and the minimum number of ISOCS 1162 measurements that will be required based on a measurement FOV of 28 m2.

1163 To ensure that the number of ISOCS measurements based on the necessary areal coverage in a STS 1164 basement surface FSS survey unit was sufficient to satisfy a statistically based sample design, a 1165 simplified calculation was performed to determine sample size using the process described in section 1166 5.6.4.1 the guidance in MARSSIM. This calculation was applied to the Class 1, Class 2 and Class 3 1167 basement surface FSSSTS survey units. For the Class 2 and Class 3 STS survey units, the statistical 1168 determination of sample size was accomplished by replacing DCGL with the BIL. If the sample size 1169 based on the statistical design required more ISOCS measurements than the number of ISOCS 1170 measurement required by the areal coverage, then the number of ISOCS measurements was adjusted to 1171 meet the larger sample size. For Class 1 FSS units where 100% areal coverage by ISOCS will be 1172 performed, the number of measurements are expected to exceed that required by the statistical test but 1173 the process is followed to confirm that this is the case. The calculation was not applied to the Class 1 1174 basement surface FSS units as sufficient ISOCS measurements will be taken in the survey units to 1175 provide 100% areal coverage. If the surface area of a Class 1 FSS unit is small, then a sufficient 1176 number of measurements will be acquired to meet the minimum statistical requirements necessary for 1177 performing the Sign Test and the FOV for the ISOCS measurement would be reduced accordingly to 1178 accommodate the minimum number of measurements required.

1179 Following the guidance in MARSSIM, the Type I decision error that was used for this calculation was 1180 set at 0.05 and the Type II decision error was set at 0.05. The upper boundary of the gray region was 1181 set at the DCGLBBFM Inventory Limit. The Lower Bound of the Gray Region (LBGR) was set at the 1182 expected fraction of the DCGLBBFM Inventory Limit in the STS survey unit. The expected fraction of 1183 the DCGLBBIL in both the Class 1 and Class 2 FSSSTS survey units was set at 50% and the expected 1184 fraction of the DCGLBBIL in both the Class 3 FSSSTS survey units was set at 1%. The standard 1185 deviation of the concrete core samples taken in the Turbine Building was used for sigma () in the STS 1186 surveyFSS units for the Turbine Building, Crib House/Forebay, and WWTF and Circulating Water 1187 Intake and Discharge Tunnels. For the Auxiliary Building basement walls, the standard deviation of the 1188 concrete core sample analysis results have excessive variability which will not be representative of the 1189 conditions at the time of the STS. For the Class 2 FSS units in the Containment basements, the entire 1190 concrete source term above the 565 foot elevation will be removed. Consequently, the results of the 1191 concrete core samples taken in the Containments are also not representative of the conditions at the time 1192 of STSFSS. As reasonable value for sigma () cannot be determined based on existing survey data, a 1193 coefficient of variation of 30% was used in accordance with the guidance in MARSSIM, section 1194 5.5.2.2. For the Class 1 survey unit in the Auxiliary Building, the standard deviation of the concrete 1195 cores analyzed for the full initial suite were used for sigma (). For the concrete in the Containment 1196 Under-Vessel area the standard deviation of the cores collected during characterization were used for 1197 sigma ().

1198

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-34 1199 Using the values above, tThe relative shift (/) was calculated as discussed in section 5.6.4.1.6 of this 1200 Chapter. The / calculations will be confirmed and documented as part of the FSS design process 1201 including evaluation of any additional data from continuing characterization. With the exception of the 1202 Under-Vessel areaIn all cases, the relative shift (/) was greater than three in all cases (3). The relative 1203 shift (/) for the Under-Vessel area was two. Consequently, a value of three (3) was used as the 1204 adjusted relative shift (/) for all FSS units other than the Under-Vessel area where a value of two was 1205 used. From Using Table 5-5 of MARSSIM, the required number of measurements (N) for use with the 1206 Sign Test, using a value of 0.05 for the Type I and Type II decision errors, is 14 measurements for a /

1207 value of three and 15 for a / value of 2. Consequently, the number of ISOCS measurements in several 1208 basement surface FSSSTS survey units was adjusted to meet the larger sample size. Table 5-11 13 1209 presents the basement surface FSSSTS survey units and the adjusted number of ISOCS measurements 1210 that will be taken in each for STSFSS.

1211 Table 5-12 Number of ISOCS Measurements per STS FSS Survey Unit based on Areal 1212 Coverage 1213 STS FSS Survey Unit Classification Area Minimum Areal Coverage Minimum # of ISOCS Measurements (m2)

(% of Area)

(FOV-28 m2)

Auxiliary BuildingAux Bldg.

542 foot Floor and Walls Class 1 2,5916,503 100%

93233 Auxiliary Building Basement Walls Class 2 3,912 10%

14 Unit 1 Containment Basement above 565 foot elevation Class 2 2,7592,465 10%

109 Unit 1 CTMT Under-Vessel Area Class 1 294 100%

11 Unit 1 Containment Basement above 565 foot elevationUnit 2 Containment Basement Class 2 2,7592,465 10%

109 Unit 2 CTMT Under-Vessel Area Class 1 294 100%

11 SFP/Transfer Canal Class 1 780723 100%

2826 Turbine Building Basement Class 3 14,86414,679 1%

56 Crib House/Forebay Class 3 13,8436,940 1%

25 Circulating Water Discharge Tunnels Class 3 4,86871 1%

2 WWTF Class 3 1,124 1%

1

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-35 As previously noted, the required areal coverage for a Class 1 basement survey unit is 100%. The Sign 1214 Test will still be performed to demonstrate with 95% confidence that the survey unit is in compliance.

1215 Also, sSufficient measurements will be taken in the Class 1 FSS unit to ensure that 100% of the surface 1216 area is surveyed (ISOCS FOV will be overlapped to ensure that there are no un-surveyed corners and 1217 gaps). In the case where the physical configuration or measurement geometry would make the 1218 acquisition of a 28 m2 FOV difficult or prohibitive, then the FOV for the ISOCS measurement may be 1219 reduced provided that the adjusted number of samples remains constant and the minimum areal 1220 coverage represented by the FSS unit classification (100% areal coverage for a Class 1 FSS unit or 10%

1221 areal coverage for a Class 2 FSS unit) is achieved.

1222 1223

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-36 Table 5-13 Adjusted Minimum Number of ISOCS Measurements per FSS UnitNumber of 1224 ISOCS Measurements per STS Survey Unit based on Areal Coverage 1225 STS FSS Survey Unit Classification Required Areal Coverage Adjusted # of ISOCS Measurements Adjusted Areal Coverage Adjusted Areal Coverage (m2)

(FOV-28 m2)

(m2)

(% of Area)

Aux Bldg. 542 foot Floor &

WallsAuxiliary Building 542 foot Floor Class 1 6,5032,591 93407(2) 6,5032,59 1

100%

Auxiliary Building Basement Walls Class 2 392 14 392 10%

Unit 1 Containment CTMT Basementabove 565 foot elevation Class 2 276247 35(1)14 392980 1440%

Unit 1 CTMT Under-Vessel Area Class 1 294 19(2) 294 100%

Unit 2 CTMT above 565 foot elevationUnit 2 Containment Basement Class 2 276247 35(1)14 980392 1440%

Unit 2 CTMT Under-Vessel Area Class 1 294 19(2) 294 100%

SFP/Transfer Canal Class 1 780723 2845(2) 780723 100%

Turbine Building Basement Class 3 147149 14 392 33%

Crib House/Forebay Class 3 69138 14 392 63%

Circulating Water Discharge Tunnels Class 3 49 14 392 8%

WWTF Class 3 11 14 392 35%

Note (1) Number of ISOCS adjusted to meet MARSSIM recommended survey size for a Class 2 structure (1,000 m2).

1226 (2) Adjusted to ensure number of measurements that will be taken in Class 1 FSS units will ensure 100% areal coverage, including overlap to ensure 1227 that there are no un-surveyed corners and gaps (FOV based on a 4m x 4m grid system).

1228 In the Class 2 basement surface FSS units (where less than 100% ISOCS coverage is required),

1229 measurement spacing will be determined in accordance with section 5.6.4.5.2 of this Chapter. The 1230 number of measurements will also be increased in survey units that exceed 1,000 m2 to correspond with 1231 the MARSSIM recommended survey size density for a Class 2 structure (measurements/1,000 m2). If 1232 the grid spacing allows, the location of the center of each ISOCS measurement FOV will be determined 1233 at a distance equal to the radius of the ISOCS FOV from the boundaries of the FSS unit and the FOV 1234

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-37 radius of other measurement locations. If possible, the FOV for individual measurements should not 1235 overlap. If FOV overlap cannot be avoided, then adjustments shall be made, including taking additional 1236 measurements if necessary to ensure that the required areal coverage is achieved. If a selected location 1237 is found to be either inaccessible or unsuitable, then the location will be adjusted to the closest adjacent 1238 suitable location. In these cases, a notation will be made in the field log and the coordinates of the new 1239 location documented. In addition to the prescribed areal coverage, additional judgmental measurements 1240 may be collected at locations with higher potential for containing elevated concentrations of residual 1241 radioactivity based on professional judgment.

1242 In the Class 3 basement surface FSS units, each measurement location will be randomly selected using 1243 a random number generator. If a selected location is found to be either inaccessible or unsuitable, then 1244 the location will be adjusted to the closest adjacent suitable location. In these cases, a notation will be 1245 made in the field log and the coordinates of the new location documented. In addition to the prescribed 1246 areal coverage, additional judgmental measurements may be collected at locations with higher potential 1247 for containing elevated concentrations of residual radioactivity based on professional judgment.In STS 1248 survey units where less than 100% ISOCS coverage is required, the location of the center of each 1249 ISOCS measurement FOV will be determined at random in the area located at a distance equal to the 1250 radius of the ISOCS FOV from the boundaries of the STS survey unit. If a randomly selected location 1251 is found to be either inaccessible or unsuitable, then the location will be adjusted to the closest adjacent 1252 suitable location. In these cases, a notation will be made in the field log and the coordinates of the new 1253 location documented.

1254 5.5.3.

Elevated Measurement Comparison for FSS of Basement Surfaces 1255 During the FSS of Class 1 basement surfaces, areas of elevated activity (defined as areas exceeding the 1256 DCGLB) may be identified and must be evaluated both individually and in total using the DCGLEMC to 1257 ensure compliance with the release criteria. The application of the DCGLEMC in Class 1 open land areas 1258 is addressed in section 5.10.4. Additional detail pertaining to the calculation of AFs and the DCGLEMC 1259 for basement surfaces is also provided in section 6.6.9 of Chapter 6.

1260 The basement surface EMC does not apply to FSS ISOCS measurements. Any ISOCS result that 1261 exceeds the DCGLB will be remediated. The EMC is only applicable to Class 1 survey units and to 1262 elevated areas less than 28 m2 in size that are located on a basement floor. The EMC does not apply to 1263 walls because it is based on the dose from the Drilling Spoils scenario which only applies to floors. As 1264 stated in section 5.5.2.1, the Class 1 survey units are Auxiliary Building basement, the concrete floor in 1265 both Under-Vessel areas of containment and the floor of the SFP/Transfer Canal.

1266 The DCGLEMC is the DCGLB modified by an AF. The AF is the magnitude by which the concentration 1267 in a concrete core can exceed the DCGLB, while maintaining compliance with the release criteria. The 1268 calculation of AF is discussed in section 6.6.9 of Chapter 6. The resulting AFs are reproduced in Table 1269 5-14.

1270 Table 5-14 Basement Surface Area Factors 1271 Nuclide Auxiliary Building Containment Under-Vessel Area Spent Fuel Pool/Transfer Canal H-3 1.22E+07 4.25E+07 3.02E+08 Co-60 2.89E+00 3.15E+00 4.20E+00

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-38 Ni-63 2.53E+04 6.51E+04 6.87E+04 Sr-90 1.51E+04 7.36E+04 9.60E+04 Cs-134 7.09E+00 2.84E+01 3.69E+01 Cs-137 2.63E+01 5.13E+01 5.49E+01 Eu-152 2.90E+00 2.91E+00 3.82E+00 Eu-154 2.90E+00 3.15E+00 3.97E+00 1272 The DCGLEMC for basement floor surface is then calculated in accordance with Equation 5-5.

1273 1274 1275 1276 1277 1278 1279 1280 Equation 5-5 1281

= AFBds 1282 where:

1283 DCGLEMC

=

DCCL for Elevated Measurement Comparison (pCi/m2);

1284 AFB

=

Basement Surface Area Factor from Table 5-14 1285 DCGLB

=

DCGLB from Table 5-3 1286 1287 As discussed in section 5.4.5, small elevated areas (smaller area than the ISOCS FOV), if present, are 1288 identified and investigated during the post-demolition survey of the floor only. The areal extent of 1289 identified elevated areas on the floor will be bounded and a concrete core sample collected at the 1290 location within the bounded area that exhibits the highest activity. If the activity in the core (summing 1291 activity in all core slices) exceeds the DCGLB values in Table 5-3, then an EMC test will be performed 1292 using the DCGLEMC calculated using Equation 5-5.

1293 Any areas that are found to exceed the DCGLB in a concrete core are included in the EMC evaluation.

1294 Each elevated area is compared to the applicable DCGLEMC. If an individual elevated area passes, then 1295 it is evaluated under the unity rule. This is performed by determining the fraction of dose contributed 1296 by the average radioactivity across the survey unit and adding the additional dose fraction attributed to 1297 each individual elevated area following the guidance provided in section 8.5.1 and section 8.5.2 of 1298 MARSSIM.

1299 The unity rule calculation is performed using Equation A-1 from NUREG-1757 as shown in Equation 1300 5-6 with the required site-specific modifications. The survey unit average activity value is divided by 1301

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-39 the DCGLB, the survey unit average value is then subtracted from the activity value in the elevated area, 1302 which is an individual core result, and the result divided by the DCGLEMC.

1303 The fractions associated with each elevated area are summed and the result must be less than unity for 1304 the survey unit to pass. If more than one elevated area is identified during FSS (i.e., exceeding the 1305 DCGLB), then a separate term will be included in Equation 5-6 for each elevated area.

1306 Equation 5-6 1307

+

< 1 1308 where:

1309

=

the survey unit average activity from ISOCS measurements (pCi/m2);

1310 DCGLB

=

the DCGL (pCi/m2) for basement surfaces (Table 5-3),

1311 CoreElev

=

the activity level in the core sample taken at the location exhibiting 1312 the highest remaining activity within the bounded elevated area 1313 identified during the post-demolition survey (pCi/m2),

1314 DCGLEMC

=

the DCGLEMC (pCi/m2) calculated in Equation 5-5 1315 5.4.3.5.5.4.

Survey Approach for FSS of Basement SurfacesSTS Survey Approach 1316 The FSS of basement surfaces at ZSRPSTS will be planned, designed, implemented and assessed as 1317 specified in MARSSIM and section 5.6. A survey package will be generated for each STS surveyFSS 1318 unit. The same area preparation, area turnover and control measures specified in section 5.6.3 will also 1319 apply to basement STS surveyFSS units. The Quality Assurance requirements specified in section 5.9 1320 will also apply to the acquisition of STS basement FSS measurements.

1321 As previously stated, the ISOCS was selected as the instrument of choice to perform STSFSS in 1322 basement surfaces. In summary, the ISOCS detector will be oriented perpendicular to the STS surface 1323 of interest. In most cases, the exposed face of the detector will be positioned at a distance of 3 meters 1324 above the surface. A plumb or stand-off guide attached to the detector will be used to establish a 1325 consistent source to detector distance and center the detector over the area of interest. With the 90-1326 degree collimation shield installed, this orientation corresponds to a nominal FOV of 28 m2.

1327 The detector to source distance may be reduced to accommodate physical constraints of a particular 1328 survey unit. In this case, the FOV will be reduced and the number of measurements increased to ensure 1329 the required STS FSS coverage as presented in Table 5-12 is achieved. In most cases, the measurement 1330 will be acquired using the ISOCS with a geometry that evaluates residual activity over the activity 1331 depth.

1332 If during the course of performing a STSFSS, measurement results are encountered that are not as 1333 expected for the surface undergoing survey, an investigation will be performed to determine the cause 1334 of the discrepancy.

1335 5.4.4.5.5.5.

Basement Surface FSS Data AssessmentSTS Data Assessment and Application of 1336 Results to BFM 1337 After a sufficient number of ISOCS measurements are taken in a FSS unit in accordance with the areal 1338 coverage requirements specified in Table 5-13, the data will be summarized, including any judgmental 1339

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-40 or investigation measurements. The measured activity for each gamma-emitting ROC (and any other 1340 gamma emitting radionuclide that is positively detected by ISOCS) will be recorded (in units of 1341 pCi/m2). Background will not be subtracted from any measurement. Using the radionuclide mixture 1342 fractions applicable to the survey unit, an inferred activity will be derived for HTD ROC using the 1343 surrogate approach specified in section 5.2.6. The surrogate ratios that will be used are presented in 1344 Table 5-9. A sum of fractions (SOF) calculation will be performed for each measurement by dividing 1345 the reported concentration of each ROC by the DCGLB for each ROC to calculate an individual ROC 1346 fraction. The individual ROC fractions will then be summed to provide a total SOF value for the 1347 measurement.

1348 As described in section 5.10.3.2, the Sign Test will be used to evaluate the remaining residual 1349 radioactivity against the dose criterion. The SOF for each measurement will be used as the weighted 1350 sum for the Sign Test. If the Sign Test demonstrates that the mean activity for each ROC is less than 1351 the DCGLB at a Type 1 decision error of 0.05, then the mean of all the total SOFs for each measurement 1352 in a given survey unit is calculated. If the Sign Test fails, or if the mean of the total SOFs in a basement 1353 exceeds one, then the survey unit will fail FSS. If a survey unit fails FSS, then the FSSsurvey unit may 1354 be reclassified, additional remediation will be performed and the FSS performed again.

1355 Once the survey data set passes the Sign test, the mean radionuclide activity (pCi/m2) for each ROC 1356 will be used to perform a calculation of dose from residual radioactivity for each basement surface FSS 1357 unit in accordance with Equation 5-7. The mean values from FSS will include the results of judgmental 1358 samples will be added to the mean FSS dose based on an area-weighted average approach.

1359 Equation 5-7 1360 DoseFSS =

Mean ActivityROC

=0 25 /

1361 where:

1362 DoseFSS

=

Reported Dose from basement surface FSS unit (mrem/yr) 1363 Mean ActivityROCi = Mean activity of radionuclide i in (pCi/m2) 1364 DCGLBROCi

=

DCGL for ROCi (pCi/m2) from Table 5-3 1365 At the completion of the STS in each survey unit, ISOCS measurement results will be assessed and 1366 evaluated in the same manner as the process presented in section 5.10 of this Chapter. STS data 1367 analysis and data evaluation will be performed to ensure that the STS DQOs have been met. Once all 1368 DQOs have been achieved, the STS will be considered complete.

1369 As described in section 5.10.3.3, the Sign Test will be used to evaluate the remaining residual 1370 radioactivity in each survey unit against the dose criterion using the Basement Dose Factors. If the Sign 1371 Test fails, the expected fraction of the BIL assumed in survey design as specified in section 5.5.2.1, can 1372 be adjusted to higher values that allow the test to pass. This assumes that the total mean inventory in 1373 the entire basement, considering all survey units is below 25 mrem/yr. In addition, if a building has 1374 multiple STS survey units (e.g. the Auxiliary Building will have three (3) STS survey units, one for the 1375 wall, one for the floor, and one for the embedded piping/penetrations remaining in the Auxiliary 1376 Building), the sum of the inventory fractions for each STS survey unit in the building must be less than 1377 one. If the sum exceeds one, then an investigation will be performed which may result in the 1378

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-41 acquisition of additional measurements, the reclassification of the STS survey unit, or additional 1379 remediation.

1380 Once all survey units in a given building pass the Sign Test, the sum of the actual observed mean total 1381 inventory values from concrete (or the steel liner in the case of the Containment Buildings) for all STS 1382 survey units in the building, as well as the source term contribution from any embedded piping and 1383 penetrations whose inventory has been allocated to the building, will be the applied as the source term 1384 in the BFM to determine the dose from residual radioactivity in the building. In accordance with the 1385 Unity Rule, the sum of the inventory fractions from all STS survey units in a building, including the 1386 dose from embedded piping and penetrations must be less than one.

1387 5.4.5.5.5.6.

Methods for STSFSS of Embedded Piping and Penetrations 1388 The end state will include embedded piping and penetrations. An embedded pipe is defined as a pipe 1389 that runs vertically through a concrete wall or horizontally through a concrete floor and is contained 1390 within a given building. A penetration is defined as a pipe (or remaining pipe sleeve, if the pipe is 1391 removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or 1392 floor, between two buildings, and is open at the wall or floor surface of each building. A penetration 1393 could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end 1394 and the outside ground on the other end. The list of penetrations and embedded piping to remain is 1395 provided in TSD 14-016. Embedded Ppipe and Ppenetrations have separate DCGLs as listed in Tables 1396 5-87 and 5-98. However, the survey methods are the same for both. The survey units for embedded 1397 pipe and penetrations are presented in Table 5-15.

1398 Table 5-15 Embedded Pipe and Penetration Survey Units 1399 Basement FSS Unit Embedded Pipe Penetrations Auxiliary Building Basement

  • Basement Floor Drains (542 ft.

elevation)

  • Unit 1 and Unit 2 In-Core Sump Drains (541 ft. elevation)
  • Unit 1 and Unit 2 Tendon Tunnel Drains
  • Unit 1 and Unit 2 Basement Floor Drains (560 ft. elevation)
  • Unit 1 and Unit 2 Steam Tunnel Floor Drains (570 ft. elevation)
  • Unit 1 and Unit 2 Tendon Tunnel Drains (1)
  • Turbine Penetrations (1) Buttress Pits/Tendon Tunnels hydraulically connected to Steam Tunnel/Turbine Building so include with Turbine 1400 Building as well as Containment 1401 1402 The vast majority of embedded piping will be removed during decommissioning. It is anticipated that 1403 the only remaining embedded piping will be the floor drain system piping in the 560 foot elevation floor 1404

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-42 of the Turbine Building. Based upon the results of characterization surveys, this system piping is 1405 expected to have very low levels of residual radioactivity. The majority of the penetrations are located 1406 in the concrete walls between the Auxiliary Building and the two Containments. In almost all cases, 1407 these penetrations are actually sleeves that housed system piping during operation. The contaminated 1408 piping will be removed and dispositioned as waste during decommissioning, leaving only the empty 1409 sleeves in the structure end-state. The remaining penetrations (sleeves) are expected to contain minimal 1410 residual radioactivity. The source term associated with any remaining residual radioactivity inventory 1411 remaining in any embedded piping or penetration located in each STS survey area will be assessed 1412 directly and added to the BFM inventory source term.

1413 on the interior surfaces of embedded pipingThe residual radioactivity remaining in each section of 1414 embedded piping/penetration applicable to each STS surveyFSS area unit will be assessed and 1415 quantified by direct survey. Shallow penetrations or short lengths of embedded pipe that are directly 1416 accessible will be surveyed using hand-held portable detectors, such as a gas-flow proportional or 1417 scintillation detector. Lengths of embedded pipe or penetrations that cannot be directly accessed by 1418 hand-held portable detectors will be surveyed using applicable sized NaI and or Cesium Iodide (CsI) 1419 detectors that will be inserted and transported through the pipe using flexible fiber-composite rods or 1420 attached to a flexible video camera/fiber-optics cable. The ISOCS may also be used to assess hard-to-1421 access embedded pipe and sleeves. The specific types of instruments that may be used for both types of 1422 scenarios are presented in section 5.8 and Table 5-1421.

1423 The interior of embedded pipe or penetration sections that cannot be accessed directly will be inspected 1424 prior to survey using a miniature video camera designed to assess the physical condition of the 1425 pipe/sleeve pipe interior surfaces. The miniature camera with supporting lighting components as well 1426 as the subsequent detectors that will be used to survey the pipe/sleeve pipe interior surfaces will be 1427 maneuvered through the pipe/sleeve pipe by the manipulation of fiber-composite rods which will be 1428 manually pushed or pulled to provide locomotion. The detectors were thenwill be deployed into the 1429 actual pipe/sleeve and a timed measurement acquired at a specified distance traversed into the pipe.

1430 This distance will be determined as a DQO based on the contamination potential in the pipe/sleevepipe.

1431 As an example, based upon a conservative area of detection for the detectors used, a measurement 1432 interval of one measurement for each foot of pipe will conservatively provided 100% areal coverage of 1433 all accessible pipe/sleeve interior surfaces. A static measurement will be acquired at a specified 1434 distance traversed into the pipe.

1435 The detector output will represent the gamma activity in gross cpm. This gamma measurement value in 1436 cpm will then be converted to dpm using an efficiency factor based on the calibration source. The total 1437 activity in dpm will adjusted for the assumed total effective surface area commensurate with the 1438 pipe/penetration diameter, resulting in measurement results in units of dpm/100 cm2. Using the 1439 appropriate conversion factors, the result is then converted to units of pCi/m2. This measurement result 1440 will then represent a commensurate and conservative gamma surface activity. Using the appropriate 1441 surrogate ratio, the gamma surface activity will then be modified to account for all applicable HTD 1442 radionuclides present in the radionuclide distribution applicable to the system. These values can then 1443 be used to derive a total inventory for the embedded pipe within a STS survey area.

1444 The gamma surface activity for each FSS measurement is then converted to a gamma measurement 1445 result (in units of pCi/m2) for each gamma ROC based on the mixture applicable to the pipe/sleeve 1446 surveyed. HTD ROC are inferred to the applicable gamma radionuclide concentration to derive a 1447

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-43 concentration for each ROC for each measurement taken. The measurement concentration for each 1448 ROC is then divided by the applicable DCGLEP to produce a dose fraction for each ROC. The 1449 individual ROC dose fractions are then summed to produce a SOF for the measurement. There is no 1450 EMC applicable to embedded pipe or penetrations. Consequently, a measurement SOF that exceeds 1451 one would require investigation and additional remediation.

1452 The total embedded pipe located within a basement will be treated as a separate FSS unit. FSS units for 1453 penetrations are grouped by basement. In situations where there are multiple survey units in a basement 1454 (e.g., surface, embedded pipe, penetration), the sum of the dose from all survey units must be less than 1455 25 mrem/yr.

1456 The total embedded pipe located within a STS survey area will be treated as a separate STS survey unit.

1457 As such, the STS FSS results for penetration and/or embedded pipe and penetration survey units will be 1458 part of the summation of the fraction of the BFM inventory source termcompliance dose calculated for 1459 each building basement in which they are located (see LTP Chapter 6, section 6.17).

1460 Embedded pipe survey units have a relatively small surface area leading to DCGLs that are higher than 1461 the wall/floor DCGL. This is due to the total internal surface area of the embedded pipe survey unit in a 1462 given basement being less than the total wall/floor surface area of the basement containing them. To 1463 eliminate the potential for activity levels in embedded pipe that could lead to releases greater than 1464 surrounding walls and floors, the following remediation and grouting action levels will be applied to 1465 measurements of surface activity in embedded pipe.

1466

  • If maximum activity exceeds the DCGLEP from Table 5-7 (SOF >1), then remediation will be 1467 performed.

1468

  • If the maximum activity in an embedded pipe exceeds the surface DCGLB from Table 5-3 (SOF>1) 1469 in the building that contains it, but is below the DCGLEP from Table 5-7, then the embedded pipe 1470 will be remediated or grouted.

1471

  • If an embedded pipe is remediated and the maximum activity continues to exceed the surface 1472 DCGLB from Table 5-3 (SOF>1), but is less than the DCGLEP, then the embedded pipe will be 1473 grouted.

1474

  • If the maximum activity is below the surface DCGLB from Table 5-3, then grouting of the pipe will 1475 not be required.

1476 As with embedded pipe, penetration survey units also have total surface areas that are less than the area 1477 of the wall/floor surface survey unit that the penetrations interface. To eliminate the potential for 1478 activity levels in penetrations that could lead to releases greater than the adjacent basement walls and 1479 floors, the following remediation and grouting action levels will be applied to measurements of surface 1480 activity in penetrations.

1481

  • If maximum activity exceeds the DCGLPN from Table 5-8 (SOF >1), then remediation will be 1482 performed.

1483

  • If the maximum activity in a penetration exceeds the most limiting DCGLB from Table 5-3 of the 1484 two basements where a penetrations interface (SOF>1), but is below the DCGLPN from Table 5-8, 1485 then the penetration will be remediated or grouted.

1486

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-44

  • If a penetration is remediated and the maximum activity continues to exceed the most limiting 1487 DCGLB from Table 5-3 of the two basements where a penetrations interface (SOF>1), but is less 1488 than the DCGLPN, then the penetration will be grouted.

1489

  • If the maximum activity is below the surface DCGLB from Table 5-3, then grouting of the 1490 penetration will not be required.

1491 The drilling spoils dose will be assessed for any embedded pipe or penetration in a floor that is 1492 accessible, which is defined as being above the eight-inch depth where heavy reinforcement begins, and 1493 has a maximum FSS measurement exceeding the wall/floor surface DCGL. The concentration in the 1494 maximum measurement will be used for the drilling spoils assessment and the resulting dose added to 1495 the dose assigned to the embedded pipe or penetration survey unit.

1496 5.5.7.

Summation of Dose for Basement Structures 1497 The BFM source term for a given basement structure includes the contributions from basement 1498 surfaces, (concrete and steel liner for Containment), embedded pipe and penetrations that are contained 1499 in, or interface with, the basement. Each dose component (surface, embedded pipe, penetrations) has a 1500 unique DCGL. Concrete fill is another dose component applicable to any basement where clean 1501 concrete debris is used as fill. This is discussed further in LTP Chapter 6, section 6.16. The total dose 1502 attributed to the use of concrete fill for each basement, including all ROC, is presented in Table 5-16, 1503 which is reproduced from Table 6-51 from LTP Chapter 6, section 6.16. The dose values in Table 5-16 1504 will be added to any basement where concrete fill is used regardless of the volume of concrete fill used.

1505 After the FSS of all dose components in a given basement is complete and all dose component survey 1506 units pass the Sign Test, the mean SOF for each dose component is calculated. The mean SOF for 1507 concrete fill is calculated by dividing the basement-specific assigned dose in Table 5-16 by 25 mrem/yr.

1508 The mean SOF includes the results of any judgmental samples or elevated areas if the EMC test is 1509 applied (EMC applicable to basement floor surface only). The basement structure dose is then 1510 calculated by summing the mean SOF from all dose components using Equation 5-8.

1511 Table 5-16 Dose Assigned to Clean Concrete Fill 1512 Basement Structure Dose (mrem/yr)

Auxiliary Building 1.010.99 Containment 1.781.77 SFP/Transfer Canal 0.160.15 Turbine Building 1.621.58 Crib House/Forebay 1.601.57 WWTF 6.576.40 1513 1514 Equation 5-8:

1515

= (+ + + ) 25 /

1516

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-45 where:

1517 SOFS

=

mean SOF for surface survey unit (walls and floors) 1518 SOFEP

=

mean SOF for embedded pipe survey unit 1519 SOFPN

=

mean SOF for penetration survey unit 1520 SOFCF

=

concrete fill dose from Table 5-16 divided by 25 mrem/yr 1521 1522 After the FSS of all dose components in a given basement is complete and all dose component survey 1523 units pass the Sign Test, the mean SOF for each dose component is calculated. The mean SOF includes 1524 the results of any judgmental samples or elevated areas if the EMC test applied. The Basement unit 1525 dose is then calculated by summing all dose component mean SOFs using Equation 5-8. Table 5-15 1526 lists the embedded pipe and penetration dose components that are included in the full Basement 1527 Structure Dose for each basement in addition to the surface dose component discussed above.

1528 5.5.7.1.

Basement Surface Dose Calculation Including Multiple Survey Units 1529 The calculation of dose from specific building surfaces (Auxiliary Building, Containments, Turbine 1530 Building and Crib House/Forebay) is the sum of the contributions from two or more surface survey 1531 units within, or connected to, the given basement. In addition, the source term from biased judgmental 1532 FSS results from the surface of the Circulating Water Intake Pipe are added to the Turbine Building and 1533 the Crib/House Forebay. The process for calculating the combined basement surface dose from each of 1534 the survey units and the calculation method is provided below. Table 5-17 lists the surface survey units 1535 that contribute to each basement.

1536 1537 After passing the Sign test, the mean dose contribution for multiple surface survey units in a given 1538 basement (and the judgmental samples in Circulating Water Intake Pipe) is determined on an area-1539 weighted basis. The total basement area used in the weighted average calculation is the adjusted 1540 surface area used to calculate the DCGL in section 6.6.8. Residual radioactivity at the DCGL will 1541 result in 25 mrem/yr only if residual radioactivity is uniformly distributed over 100% of the adjusted 1542 surface area. The adjusted areas used for the DCGL calculations, and applied in the weighted average 1543 calculation of total basement surface dose are provide in Table 5-18, which is reproduced from Chapter 1544 6, section 6.6.8.1, Table 6-23.

1545 Table 5-17 Surface Survey Units Contributing to Each Basement 1546 Basement Surface Survey Unit 1 Surface Survey Unit 2 Surface Survey Unit 3 Surface Survey Unit 4 Auxiliary All walls and floors SFP/Transfer Canal N/A N/A Containment 565elevation steel liner floor and walls above 565 elevation Under-Vessel Area SFP/Transfer Canal N/A

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-46 SFP/ Transfer Canal All walls and floors N/A N/A N/A Turbine All walls and floors Circulating Water Discharge Tunnel Circulating Water Intake Pipe (1)

Buttress Pits/

Tendon Tunnels1 Crib House/Forebay All walls and floors Circulating Water Intake Pipe (1)

N/A N/A WWTF All walls and floors N/A N/A N/A (1) Judgmental samples only - Circulating Water Intake Pipe and Buttress Pits/Tendon Tunnels are not survey units.

1547 Table 5-18 Adjusted Basement Surface Areas for Area-Weighted SOF Calculation 1548 Basement Structures Included in Area-Weighted SOF Calculation Adjusted SA m2 Containment Containment + SFP/Transfer Canal 3,482 Auxiliary Building Auxiliary + SFP/Transfer Canal 7,226 Turbine Building Turbine + Circulating Water Discharge Tunnel + Circulating Water Intake Pipe + Circulating Water Discharge Pipe + Buttress Pits/Tendon Tunnels 27135 Crib House/Forebay Crib House/Forebay + Circulating Water Intake Pipe 18254 1549 1550 The calculation of the area-weighted SOF for the four basements that have dose contributions from 1551 multiple surface survey units (and/or Circulating Water Discharge Pipe) is shown in Equation 5-9.

1552 1553 1554 1555 Equation 5-9 1556

,=,

=1 1557 where:

1558 SOFS,B

= total surface SOF including all surface survey units in 1559 basement (B) 1560 SASUi,B

= surface area of survey unit (i) 1561

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-47 SAAdjust, B

= adjusted surface area for DCGL calculation in Table 5-18 for 1562 basement (B) 1563 SOFSUi,B

= Sum of fraction for survey unit (i) in basement (B) 1564 1565 5.5.5.6.Final Status Survey (FSS) Design 1566 FSS design is the process used to generate FSS packages and sample plans that when implemented, are 1567 designed to demonstrate compliance with the dose-based unrestricted release criteria at ZSRP. Survey 1568 design in this section specifically pertains to open land survey units and buried pipe; however the 1569 application of survey planning, survey package development, DQOs, data quality, investigations and 1570 data assessment as specified in this section is applicable to all FSS, including basement surfaces as 1571 described section 5.5. Buried piping is defined as pipe that runs through soil and is addressed in section 1572 5.7.1.9. The FSS design for basement surfaces, embedded pipe and penetrations is described in section 1573 5.5.This process will pertain primarily to open land survey units and buried pipe at ZNPS. The future 1574 dose to groundwater associated with remaining solid concrete structures and embedded pipe will be 1575 quantified by the STS. Any minor above-grade structures that will remain on the site (e. g. ISFSI 1576 Warehouse, Sewage Lift Station, etc.) will be released for unrestricted use using the survey approach 1577 from MARSAME.

1578 5.5.1.5.6.1.

Survey Planning 1579 FSS provides data to demonstrate that all radiological parameters in a specific survey unit satisfy the 1580 conditions for unrestricted release. The primary objectives of the FSS are to:

1581

  • verify survey unit classification; 1582
  • demonstrate that the potential dose from residual radioactivity is below the release criterion for each 1583 survey unit; and, 1584
  • demonstrate that the potential dose from small areas of elevated radioactivity is below the release 1585 criterion for each survey unit.

1586 The FSS process consists of four principal elements:

1587

  • Planning; 1588
  • Design; 1589
  • Implementation; and, 1590
  • Data Assessment 1591 The DQO and Data Quality Assessment (DQA) processes are applied to these four principal elements.

1592 DQOs allow for systematic planning and are specifically designed to address problems that require a 1593 decision to be made and provide alternate actions (as is the case in FSS). The DQA process is an 1594 evaluation method used during the assessment phase of the FSS to ensure the validity of survey results 1595 and demonstrate achievement of the sampling plan objectives (e.g., to demonstrate compliance with the 1596 release criteria in a survey unit).

1597

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-48 Survey planning includes review of the HSA, the results of the site characterization, and other pertinent 1598 radiological survey information to establish the ROC and survey unit classifications. Survey units are 1599 fundamental elements for which FSS are designed and executed. The classification of a survey unit 1600 determines how large it can be in terms of surface area.

1601 Before the FSS process can proceed to the implementation phase, turnover and control measures will be 1602 implemented for an area or survey unit as appropriate. A formal turnover process will ensure that 1603 decommissioning activities have been completed and that the area or survey unit is in a suitable 1604 physical condition for FSS implementation. Isolation and control measures are primarily used to limit 1605 the potential for cross-contamination from other decommissioning activities and to maintain the final 1606 configuration of the area or survey unit.

1607 Survey implementation is the process of carrying out the survey plan for a given survey unit. This 1608 consists of scan measurements, total surface contamination measurements, and collection and analysis 1609 of samples. Quality assurance and control measures are employed throughout the FSS process to 1610 ensure that subsequent decisions are made on the basis that data is of acceptable quality. Quality 1611 assurance and control measures are applied to ensure:

1612

  • DQOs are properly defined and derived; 1613
  • the plan is correctly implemented as prescribed; 1614
  • data and samples are collected by individuals with the proper training using approved procedures; 1615
  • instruments are properly calibrated and source checked; 1616
  • collected data are validated, recorded, and stored in accordance with approved procedures; 1617
  • documents are properly maintained; and, 1618
  • corrective actions are prescribed, implemented and followed up, if necessary.

1619 The initial open land survey units and survey unit classifications that will be used for the FSS of Zion 1620 are presented in LTP Chapter 2, section 2.1.6 and Table 2-4 and shown on Figures 2-4, 2-5, 2-6, and 1621 2-7. A FSS Package will be prepared for each applicable survey unit. This survey package is a 1622 collection of documentation detailing FSS Sample Plan survey design, survey implementation and data 1623 evaluation. A FSS Package may contain one or more FSS Sample Plans. FSS Packages shall be 1624 controlled in accordance with the record quality requirements of ZionSolutions QAPP.

1625 5.5.2.5.6.2.

Data Quality Objectives 1626 The DQO process will be incorporated as an integral component of the data life cycle, and is used in the 1627 planning phase for scoping, characterization, remediation and FSS plan development using a graded 1628 approach. Survey plans that are complex or that have a higher level of risk associated with an incorrect 1629 decision (such as FSS) require significantly more effort than a survey plan used to obtain data relative 1630 to the extent and variability of a contaminant. The DQO process entails a series of planning steps found 1631 to be effective in establishing criteria for data quality and developing survey plans. DQOs allow for 1632 systematic planning and are specifically designed to address problems that require a decision to be 1633 made and provide alternate actions. Furthermore, the DQO process is flexible in that the level of effort 1634 associated with planning a survey is based on the complexity of the survey and nature of the hazards.

1635 The DQO process is iterative allowing the survey planning team to incorporate new knowledge and 1636

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-49 modify the output of previous steps to act as input to subsequent steps. The appropriate design for a 1637 given survey will be developed using the DQO process as outlined in Appendix D of MARSSIM. The 1638 seven steps of the DQO process are outlined in the following sections.

1639 5.5.2.1.5.6.2.1.

State the Problem 1640 The first step of the planning process consists of defining the problem. This step provides a clear 1641 description of the problem, identification of planning team members (especially the decision-makers), a 1642 conceptual model of the hazard to be investigated and the estimated resources. The problem associated 1643 with FSS is to determine whether a given survey unit meets the radiological release criterion of 1644 10 CFR 20.1402.

1645 5.5.2.2.5.6.2.2.

Identify the Decision 1646 This step of the DQO process consists of developing a decision statement based on a principal study 1647 question (i.e., the stated problem) and determining alternative actions that may be taken based on the 1648 answer to the principal study question. Alternative actions identify those measures to resolve the 1649 problem. The decision statement combines the principal study question and alternative actions into an 1650 expression of choice among multiple actions. For the FSS, the principal study question is does 1651 residual radioactive contamination that is present in the survey unit exceed the established DCGLw 1652 values? The alternative actions may include no action, investigation, resurvey, remediation and 1653 reclassification.

1654 Based on the principal study question and alternative actions listed above, the decision statement for the 1655 FSS is to determine whether or not the average radioactivity concentration for a survey unit results in a 1656 SOF less than unity.

1657 5.5.2.3.5.6.2.3.

Identify Inputs to the Decision 1658 The information required depends on the type of media under consideration (e.g., soil, water) and 1659 whether existing data are sufficient or new data are needed to make the decision. If the decision can be 1660 based on existing data, then the source(s) will be documented and evaluated to ensure reasonable 1661 confidence that the data are acceptable. If new data are needed, then the type of measurement (e.g.,

1662 scan, direct measurement and sampling) will need to be determined.

1663 Sampling methods, sample quantity, sample matrix, type(s) of analyses and analytic and measurement 1664 process performance criteria, including detection limits, are established to ensure adequate sensitivity 1665 relative to the release criteria.

1666 The following information will be utilized to support the decision:

1667

  • use of surrogate relationships to infer HTD ROC; 1669
  • minimum detectable concentrations; and, 1670
  • measurement and sampling results.

1671

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-50 5.5.2.4.5.6.2.4.

Define the Study Boundaries 1672 This step of the DQO process includes identification of the target population of interest, the spatial and 1673 temporal features of the population pertinent to the decision, time frame for collecting the data, practical 1674 constraints and the scale of decision making. In FSS, the target population is the set of samples or 1675 direct measurements that constitute an area of interest (i.e., the survey unit). The medium of interest 1676 (e.g., soil, water) is specified during the planning process. The spatial boundaries include the entire 1677 area of interest including soil depth, area dimensions, contained water bodies and natural boundaries, as 1678 needed. Temporal boundaries include those activities impacted by time-related events including 1679 weather conditions, seasons, operation of equipment under different environmental conditions, resource 1680 loading and work schedule.

1681 5.5.2.5.5.6.2.5.

Develop a Decision Rule 1682 This step of the DQO process develops the binary statement that defines a logical process for choosing 1683 among alternative actions. The decision rule is a clear statement using the If...then... format and 1684 includes action level conditions and the statistical parameter of interest (e.g., mean of data). Decision 1685 statements can become complex depending on the objectives of the survey and the radiological 1686 characteristics of the affected area.

1687 For FSS, the decision rule will be based on the question pertaining to whether or not the radioactivity 1688 concentration of residual radioactivity in a survey unit exceeds the applicable DCGLw value.

1689

  • If the SOF is less than unity (1), then no additional investigation will be performed and the survey 1690 unit meets the criteria for unrestricted release.

1691

  • If the SOF is greater than or equal to unity (1), then the survey unit does not meet the criteria for 1692 unrestricted release. Additional remediation followed by FSS redesign and resurvey will be 1693 performed.If the SOF is greater than or equal to unity (1), then the survey unit does not meet the 1694 criteria for unrestricted release and, further action, including but not limited to additional 1695 remediation, survey unit reclassification, additional data collection, or dose assessment will be 1696 taken.

1697 5.5.2.6.5.6.2.6.

Specify Limits on Decision Errors 1698 This step of the DQO process incorporates hypothesis testing and probabilistic sampling distributions to 1699 control decision errors during data analysis. Hypothesis testing is a process based on the scientific 1700 method that compares a baseline condition to an alternate condition. The baseline condition is 1701 technically known as the null hypothesis. Hypothesis testing rests on the premise that the null 1702 hypothesis is true and that sufficient evidence must be provided for rejection.

1703 The primary consideration during FSS will be demonstrating compliance with the release criterion. For 1704 FSS, the null hypothesis is expressed as the survey unit exceeds the criteria for unrestricted release.

1705 Decision errors occur when the data set leads the decision-maker to make false rejections or false 1706 acceptances during hypothesis testing. For the design of FSS at ZNPS, the error (Type I error) will 1707 always be set at 0.05 (5 percent) unless prior NRC approval is granted for using a less restrictive value.

1708 The error (Type II error) will also be initially set at 0.05 (5 percent). However, the Type II error may 1709 be adjusted with the concurrence of the Characterization/License Termination Manager, after weighing 1710

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-51 the resulting change in the number of required sample or measurement locations against the risk of 1711 unnecessarily investigating and/or remediating survey units that are truly below the release criterion.

1712 Another output of this step is assigning probability limits to points above and below the gray region 1713 where the consequences of decision errors are considered acceptable. The upper bound corresponds to 1714 the release criteria. The Lower Bound of the Gray Region (LBGR) is determined as another limit on 1715 decision error. LBGR is influenced by a parameter known as the relative shift. The relative shift is the 1716 DCGLW minus the LBGR (i.e., the width of the Gray Region) divided by the standard deviation of the 1717 data set used to design the survey. In accordance with NUREG-1757, Appendix A, the LBGR should 1718 be set at the mean concentration of residual radioactivity that is estimated to be present in the survey 1719 unit. However, if no other information is available regarding the survey unit, the LBGR may be 1720 initially set equal to 0.5 times the applicable DCGLW. However, if the relative shift exceeds a value of 1721 3, then the LBGR should be adjusted until the relative shift value is equal to 3. The adjustment of 1722 decision errors areis discussed in more detail in section 5.6.4.

1723 Sample uncertainty is controlled by collecting a small frequency of additional samples from each 1724 survey unit. Analytical uncertainty is controlled by using appropriate instrumentation, methods, 1725 techniques, training, and Quality Control (QC). The MDC values for individual radionuclides using 1726 specific analytical methods will be established. Uncertainty in the decision to release areas for 1727 unrestricted use is controlled by the number of samples and/or measurement points in each survey unit 1728 and the uncertainty in the estimate of the mean radionuclide or gross radioactivity concentrations. The 1729 specific types of instruments that may be used for the FSS of Zion and their respective MDC values are 1730 presented in section 5.8 and Tables 5-14 21 and 5-1522.

1731 Graphing the probability that a survey unit does not meet the release criteria may be used during FSS.

1732 This graph, known as a power curve, may be performed retrospectively (i.e., after FSS) using actual 1733 measurement data. This retrospective power curve may be important when the null hypothesis is not 1734 rejected (i.e., the survey unit does not meet the release criteria) to demonstrate that the DQOs have been 1735 met.

1736 5.5.2.7.5.6.2.7.

Optimize the Design for Obtaining Data 1737 The first six steps of the DQO process develop the performance goals of the survey. This final step in 1738 the DQO process leads to the development of an adequate survey design.

1739 By using an on-site analytical laboratory, sampling and analyses processes are designed to provide near 1740 real-time data assessment during implementation of field activities and FSS. Gamma scans provide 1741 information on soil areas that have residual radioactivity greater than background and allow appropriate 1742 selection of biased sampling and measurement locations. This data will be evaluated and used to refine 1743 the scope of field activities to optimize implementation of the FSS design and ensure the DQOs are met.

1744 5.5.3.5.6.3.

Area Preparation: Turnover and Control Measures 1745 Following the conclusion of remediation activities and prior to initiating FSS, isolation and control 1746 measures will be implemented. The determination of readiness for controls and the preparation for FSS 1747 will be based on the results of characterization, Radiological Assessments (RA), and/or RASS that 1748 indicate residual radioactivity is unlikely to exceed the applicable DCGLs in the respective survey unit.

1749 The control measures will be implemented to ensure the final radiological condition is not compromised 1750 by the potential for re-contamination as result of access by personnel or equipment.

1751

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-52 These measures will consist of both physical and administrative controls. Examples of the physical 1752 controls include rope boundaries and postings indicating that access is restricted to only those persons 1753 authorized to enter by the Characterization/License Termination group. Administrative controls include 1754 approved procedures and personnel training on the limitations and requirements for access to areas 1755 under these controls. In the event that additional remediation is required in an area following the 1756 implementation of isolation and control measures, local contamination control measures will be 1757 employed as appropriate.

1758 Prior to transitioning an area from decommissioning activities to isolation and control, a walk down 1759 may be performed to identify access requirements and to specify the required isolation and control 1760 measures. The physical condition of the area will also be assessed, with any conditions that could 1761 interfere with FSS activities identified and addressed. If any support equipment is needed for FSS 1762 activities, it will be evaluated to ensure that it does not pose the potential for introducing radioactive 1763 material into the area. Industrial safety and work practice issues, such as access to high areas or 1764 confined spaces, will also be identified during the pre-survey evaluation.

1765 Open land areas, access roads and boundaries will be posted (as well as informational notices) with 1766 signs instructing individuals to contact Characterization/License Termination group personnel prior to 1767 conducting work activities in the area. For open land areas that do not have positive access control (i.e.,

1768 areas that have passed FSS but are not surrounded by a fence), the area will be inspected periodically 1769 and any material or equipment that has been introduced into the area since the last inspection will be 1770 investigated (i.e., scanned and/or sampled).

1771 Isolation and control measures will be implemented through approved plant procedures and will remain 1772 in force throughout FSS activities and until there is no risk of recontamination from decommissioning 1773 or the survey area has been released from the license.

1774 5.5.4.5.6.4.

Final Status Survey Design Process 1775 The general approach prescribed by MARSSIM for FSS requires that at least a minimum number of 1776 measurements or samples be taken within a survey unit, so that the non-parametric statistical tests used 1777 for data assessment can be applied with adequate confidence. Decisions regarding whether a given 1778 survey unit meets the applicable release criterion are made based on the results of these tests. Scanning 1779 measurements are used to confirm the design basis for the survey by evaluating if any small areas of 1780 elevated radioactivity exist that would require reclassification, tighter grid spacing for the total surface 1781 contamination measurements, or both.

1782 The level of survey effort required for a given survey unit is determined by the potential for 1783 contamination as indicated by its classification. Class 3 survey units receive judgmental (biased) 1784 scanning and randomly located measurements or samples. Class 2 survey units receive scanning over a 1785 portion of the survey unit based on the potential for contamination, combined with total surface 1786 contamination measurements or sampling performed on a systematic grid. Class 1 survey units receive 1787 scanning over 100 percent of the survey unit combined with total surface contamination measurements 1788 or sampling performed on a systematic grid. Depending on the sensitivity of the scanning method, the 1789 grid spacing may need to be adjusted to ensure that small areas of elevated radioactivity are detected.

1790

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-53 5.5.4.1.5.6.4.1.

Sample Size Determination 1791 Section 5.5 of MARSSIM and Appendix A of NUREG-1757 both describe the process for determining 1792 the number of sampling and measurement locations (sample size) necessary to ensure an adequate set of 1793 data that are sufficient for statistical analysis such that there is reasonable assurance that the survey unit 1794 will pass the requirements for release. The number of sampling and measurement locations is 1795 dependent upon the anticipated statistical variation of the final data set such as the standard deviation, 1796 the decision errors, and a function of the gray region as well as the statistical tests to be applied.

1797 5.5.4.1.1.5.6.4.1.1.

Decision Errors 1798 The probability of making decision errors is established as part of the DQO process in establishing 1799 performance goals for the data collection design and can be controlled by adopting a scientific approach 1800 through hypothesis testing. In this approach, the survey results will be used to select between the null 1801 hypothesis or the alternate condition (the alternative hypothesis) as defined and shown below.

1802

  • Null Hypothesis (H0) - The survey unit does not meet the release criterion; and, 1803
  • Alternate Hypothesis (Ha) - The survey unit does meet the release criterion.

1804 A Type I decision error would result in the release of a survey unit containing residual radioactivity 1805 above the release criterion, or false negative. This occurs when the null hypothesis is rejected when in 1806 fact it is true. The probability of making this error is designated as.

1807 A Type II decision error would result in the failure to release a survey unit when the residual 1808 radioactivity is below the release criterion, or false positive. This occurs when the null hypothesis is 1809 accepted when it is in fact not true. The probability of making this error is designated as.

1810 Appendix E of NUREG-1757 recommends using a Type I error probability () of 0.05 and states that 1811 any value for the Type II error probability () is acceptable. Following the guidance in NUREG-1757, 1812 the decision error(s) that will be used for the FSS at ZSRP are:

1813

  • the value will always be set at 0.05 (5 percent) unless prior NRC approval is granted for using a 1814 less restrictive value; and, 1815
  • the value will also be initially set at 0.05 (5 percent), but may be modified, as necessary, after 1816 weighing the resulting change in the number of required sampling and measurement locations 1817 against the risk of unnecessarily investigating and/or remediating survey units that are truly below 1818 the release criterion.

1819 5.5.4.1.2.5.6.4.1.2.

Unity Rule 1820 The unity rule or SOF, as discussed in section 5.2.57, will be used for the survey planning and data 1821 evaluations for soil sample analyses since multiple radionuclide-specific measurements will be 1822 performed. As a result, the evaluation criteria and data must be normalized in order to accurately 1823 compare and relate the various data measurements to the release criteria.

1824 5.5.4.1.3.5.6.4.1.3.

Gray Region 1825 The gray region is defined in MARSSIM as the range of values for the specified parameter of interest 1826 for the survey unit in which the consequences of making a decision error is relatively minor. This can 1827

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-54 be explained as the range of values for which there is a potential of making a decision error; however, 1828 there is reasonable assurance that the parameters will meet the specified criteria for the rejection of the 1829 null hypothesis.

1830 The gray region is established by setting an upper and lower boundary. Values for the specified 1831 parameter above and below these boundaries usually result in a black and white or go no go 1832 decision. Values between the upper and lower boundary are within the gray region where decision 1833 errors apply most. By establishing the decision errors as specified above based on acceptable risk, the 1834 number of sampling and measurement locations may be controlled within reason.

1835 5.5.4.1.4.5.6.4.1.4.

Upper Bound of the Gray Region 1836 For the purposes of the FSS, release parameters at or near the release guidelines will typically result in a 1837 decision that the survey unit will not meet the requirements for release, with the exception of evaluating 1838 elevated areas. As a result, the upper boundary of the gray region is typically set as the DCGLw.

1839 5.5.4.1.5.5.6.4.1.5.

Lower Bound of the Gray Region 1840 The LBGR is the point at which the Type II error (), or false positive, applies. In accordance with 1841 NUREG-1757, Appendix A, the LBGR should be set at the mean concentration of residual radioactivity 1842 that is estimated to be present in the survey unit. However, if no other information is available 1843 regarding the survey unit, the LBGR may be initially set equal to 0.5 times the applicable DCGLW and 1844 may be set as low as the MDC for the specific analytical technique. This will help in maximizing the 1845 relative shift and effectively reduce the number of required sampling and measurement locations based 1846 upon acceptable risks and decision errors.

1847 5.5.4.1.6.5.6.4.1.6.

Relative Shift 1848 The relative shift (/) for the survey unit data set is defined as shift (), which is the upper boundary 1849 of the gray region, or DCGLw, minus the LBGR, divided by sigma (), which is the standard deviation 1850 of the data set used for survey design. For survey design purposes, sigma values in a survey unit and/or 1851 reference area may initially be calculated from preliminary survey and/or investigation data to assess 1852 the readiness of a survey area for FSS. For survey units where no significant concentrations of residual 1853 radioactivity are identified or anticipated, then survey design for FSS will be use a coefficient of 1854 variation of 30% as a reasonable value for sigma () in accordance with the guidance in MARSSIM, 1855 section 5.5.2.2. Standard deviation values, as determined from the characterization data are generally 1856 not recommended for Class 1 areas as this will typically contain values in excess of the guidelines and 1857 have excessive variability which will not be representative of the conditions at the time of the FSS. The 1858 standard deviation at the time of the FSS will be approximated as best as possible to ensure the FSS 1859 requirements are not too restrictive. This may be accomplished by taking additional measurements in a 1860 survey unit prior to performing FSS to establish an acceptable standard deviation. The optimal value 1861 for the relative shift should range between (and including) 1 and 3.

1862 5.5.4.2.5.6.4.2.

Statistical Tests 1863 At ZSRP, the Sign Test will be used for the statistical evaluation of the survey data. The Sign Test will 1864 be implemented using the unity rule, surrogate methodologies, or combinations thereof as described in 1865 MARSSIM and Chapters 11 and 12 of NUREG-1505.

1866

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-55 The Sign Test is the most appropriate test for FSS at Zion, as background is expected to constitute a 1867 small fraction of the DCGLw based on the results of characterization surveys. Consequently, the Sign 1868 Test will be applied when demonstrating compliance with the unrestricted release criteria without 1869 subtracting background.Appropriate tests will be used for the statistical evaluation of the survey data.

1870 Tests such as the Sign Test and Wilcoxon Rank Sum (WRS) will be implemented using the unity rule, 1871 surrogate methodologies, or combinations thereof as described in MARSSIM and Chapters 11 and 12 of 1872 NUREG-1505.

1873 If background is a significant fraction of the DCGLw, the WRS test will be used. If the contaminant is 1874 not in the background or constitutes a small fraction of the DCGLw, the Sign Test will be used.

1875 The Sign Test is expected to be the most appropriate test for open land FSS at Zion, as background is 1876 expected to constitute a small fraction of the DCGLw based on the results of characterization surveys.

1877 Consequently, ZSRP intends to apply the Sign Test to open land survey units when demonstrating 1878 compliance with the unrestricted release criteria without subtracting background. If a situation is 1879 encountered where background is a significant fraction of the DCGLw, the WRS Test may be used. The 1880 determination of which test to use will be integral to the DQO process implemented during the FSS 1881 design of each survey unit.

1882 5.5.4.2.1.

WRS Test Sample Size 1883 The number of sampling and measurement locations (N) that will be collected will be determined by 1884 establishing the acceptable decision errors, calculating the relative shift, and using Table 5-5 of 1885 MARSSIM. As stated in section 5.6.4.1.6, optimal values for the relative shift are between (and 1886 including) 1 to 3. Smaller values for relative shift substantially increase the number of required 1887 sampling and measurement locations, while larger values do little to reduce the required number.

1888 By reading the relative shift from the left side of the Table 5-5 of MARSSIM and cross referencing to 1889 the specified decision errors, the number of sampling and measurement locations can be determined.

1890 The specified number within the table includes the recommended 20 percent adjustment or increase to 1891 attain the desired power level with the statistical tests and allow for possible lost or unusable data.

1892 Equation 5-2 of MARSSIM may alternatively be used to calculate the number of sampling and 1893 measurement locations. The result will be increased by 20 percent. The sample size calculations may 1894 be performed using a specially designed software package such as COMPASS or, as necessary, using 1895 hand calculations and/or spreadsheets.The number of sampling and measurement locations (N/2) that 1896 will be collected from the reference area and survey unit will be determined by establishing the 1897 acceptable decision errors, calculating the relative shift, and using Table 5-3 of MARSSIM. As stated 1898 in section 5.6.4.1.6, optimal values for the relative shift are between (and including) 1 to 3. Smaller 1899 values for relative shift substantially increase the number of required sampling and measurement 1900 locations, while larger values do little to reduce the required number.

1901 By reading the relative shift from the left side of the Table 5-3 of MARSSIM and cross referencing to 1902 the specified decision errors, the number of sampling and measurement locations can be determined.

1903 The specified number within the table includes the recommended 20 percent adjustment or increase to 1904 ensure an adequate set of data is collected for statistical purposes. Equation 5-1 of NUREG-1507 may 1905 alternatively be used to calculate the number of sampling and measurement locations. The result will 1906 be rounded up by 20 percent. Note that N/2 locations will be identified in both the survey unit and 1907

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-56 reference area. The sample size calculations may be performed using a specially designed software 1908 package such as COMPASS or, as necessary, using hand calculations and/or spreadsheets.

1909 Sign Test Sample Size 1910 For the Sign Test, the number of sampling and measurement locations that will be required is 1911 determined from Table 5-5 of MARSSIM in a similar manner as for the WRS Test, except that a 1912 reference area is not used. The specified values within the table also include the recommended 1913 20 percent adjustment or increase to ensure an adequate set of data is collected for statistical purposes.

1914 Equation 5-2 of MARSSIM may alternatively be used to calculate the number of sampling and 1915 measurement locations. The result will be increased by 20 percent. The sample size calculations may 1916 be performed using a specially designed software package such as COMPASS or, as necessary, using 1917 hand calculations and/or spreadsheets.

1918 5.5.4.3.5.6.4.3.

Small Areas of Elevated Activity 1919 Section 2.5.1.1 of MARSSIM addresses the concern of small areas of elevated radioactivity in the 1920 survey unit. Rather than using statistical methods, a simple comparison to an investigation level is used 1921 to assess the impact of potential elevated areas. This is referred to as the Elevated Measurement 1922 Comparison (EMC). The investigation level for this comparison is the DCGLEMC, which is the DCGLw 1923 modified by an AF to account for the small area of the elevated radioactivity. The area correction is 1924 used because the exposure assumptions are the same as those used to develop the DCGLw. Note that 1925 the consideration of small areas of elevated radioactivity typically applies only to Class 1 survey units 1926 as Class 2 and Class 3 survey units should not have contamination in excess of the DCGLw. For 1927 basement surfaces, the application of the DCGLEMC is addressed in section 5.5.3. The EMC does not 1928 apply to buried pipe because all buried pipe will be remediated to the buried pipe DCGLs in Table 5-6.

1929 The statistical tests that determine if the residual radioactivity exceeds the DCGLw are not adequate for 1930 providing assurance that small areas of elevated radioactivity are successfully detected, as discussed in 1931 section 5.5.2.4 of MARSSIM. Systematic sampling and measurement locations in conjunction with 1932 surface scanning are used to obtain adequate assurance that small elevated areas comply with the 1933 DCGLEMC; however, the number of statistical systematic sampling and measurement locations must be 1934 compared to the scan sensitivity to determine the adequacy of the sampling density. The calculation of 1935 the DCGLEMC is detailed in section 5.2.810.

1936 The comparison begins by determining the area bounded by the statistical systematic sampling and 1937 measurement locations. This value is calculated by dividing the area of the survey unit (ASU) by N or 1938 N/2 for the Sign or WRS test, respectively.

1939 1940 1941 1942 Equation 5-105-5 1943 A=

1944 where:

1945

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-57 A

=

Area bounded by samples; 1946 ASU

=

Area of the survey unit; and 1947 n

=

number of samples (N [Sign test] or N/2 [WRS test]).

1948 1949 The AF is selected from Tables 5-7 10 and 5-8 11 for soils corresponding to the bounded area (A) 1950 calculated. If the calculated bounded area (A) falls between two area categories on Tables 5-10 and 5-1951 115-7 and 5-8, then the larger of the two areas will be selected along with the corresponding AF.

1952 DCGLEMC is then derived by multiplying the selected AF by the applicable DCGLw.

1953 The required scan MDC, which is equal to the DCGLEMC, is then compared to the actual scan MDC. If 1954 the actual scan MDC is less than or equal to the required scan MDC, then the spacing of the statistical 1955 systematic sampling and measurement locations is adequate to detect small areas of elevated 1956 radioactivity. If the actual scan MDC is greater than the required scan MDC, then the spacing between 1957 locations needs to be reduced due to the lack of scanning sensitivity.

1958 To reduce the spacing, a new number of sampling and measurement locations must be calculated. First, 1959 a new AF that corresponds to the actual scan MDC is calculated as follows; 1960 Equation 5-115-6 1961 AF=

1962 Next, the adjusted AF is used to look up a new adjusted area (A) from Tables 5-10 and 5-115-7 and 5-1963

8. Finally, using the adjusted area (A), an adjusted number of statistical systematic sampling and 1964 measurement locations (nEMC) is calculated as follows; 1965 Equation 5-125-7 1966

=

1967 Therefore, the number of systematic sampling and measurement locations in the survey unit will be 1968 adjusted to equal to the value derived for nEMC. When using the WRS test, the number of locations 1969 collected in the reference area will not be adjusted. When multiple measured radionuclides are present, 1970 this process is repeated for each measured radionuclide or the surrogate radionuclide, if a surrogate 1971 radionuclide is used. The greatest number of systematic sampling and measurement locations 1972 determined from the radionuclides will be used for the survey design.

1973 5.5.4.4.5.6.4.4.

Scan Coverage 1974 The purpose of scan measurements is to confirm that the area was properly classified and that any small 1975 areas of elevated radioactivity are within acceptable levels (i.e., are less than the applicable DCGLEMC).

1976 Depending on the sensitivity of the scanning method used, the number of total surface contamination 1977 measurement locations may need to be increased so the spacing between measurements is reduced.

1978 The amount of area to be covered by scan measurements is presented in Table 5-1219, which is 1979 reproduced from the portion of Table 5.9 from MARSSIM pertaining to the FSS of open land survey 1980 units. As intended by the guidance, the emphasis will be placed on a higher frequency of scans in areas 1981

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-58 of higher risk. The scan coverage requirements that will be applied for scans performed in support of 1982 the FSS of open land survey units are:

1983

  • For Class 1 survey units, 100 percent of the accessible soil surface will be scanned; 1984
  • For Class 2 survey units, between 10 percent and 100 percent of the accessible soil surface will be 1985 scanned, depending upon the potential of contamination. The amount of scan coverage for Class 2 1986 survey units will be proportional to the potential for finding areas of elevated radioactivity or areas 1987 close to the release criterion. Accordingly, the site will use the results of individual measurements 1988 collected during characterization to correlate this radioactivity potential to scan coverage levels; 1989
and, 1990
  • For Class 3 survey units, judgmental (biased) surface scans will typically be performed on areas 1991 with the greatest potential of contamination. For open land areas, this may include surface drainage 1992 areas and collection points.

1993 5.5.4.5.5.6.4.5.

Reference Grid, Sampling and Measurement Locations 1994 The survey sampling and measurement locations are a function of the sample size and the survey unit 1995 size. The guidance provided in section 4.8.5 and section 5.5.2.5 of MARSSIM has been incorporated in 1996 this section. For the FSS open land survey units, reference coordinates will be acquired using a Global 1997 Positioning System (GPS) coupled with the North American Datum (NAD) standard topographical grid 1998 coordinate system.

1999 2000 2001 Table 5-19 Recommended Survey Coverage for Open Land Areas 2002 Area Classification Surface Scans Soil Samples/Static Measurements Class 1 100%

Number of sample/measurement locations for statistical test, additional sample/measurements to investigate areas of elevated activity Class 2 10% to 100%, Systematic and Judgmental Number of sample/measurement locations for statistical test Class 3 Judgmental Number of sample/measurement locations for statistical test 5.5.4.5.1.5.6.4.5.1.

Reference Grid 2003 A reference grid will be used for reference purposes and to locate the sampling and measurement 2004 locations. The reference grid may be physically marked during the survey to aid in the collection of 2005 samples and measurements. At a minimum, each survey unit will have a benchmark defined that will 2006 serve as an origin for documenting survey efforts and results. This benchmark (origin) will be provided 2007 on the map or plot included in the FSS package.

2008

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-59 5.5.4.5.2.5.6.4.5.2.

Systematic Sampling and Measurement Locations 2009 Systematic sampling and measurement locations for Class 1 and Class 2 survey units will be located in 2010 a systematic pattern or grid. The grid spacing (L), will be determined using a triangular or square grid.

2011 Where in most cases, a triangular grid will be preferred, a square grid may be used if the physical 2012 dimensions of a survey unit are conducive to the square grid approach. The equations used to 2013 determine the grid spacing for systematic measurement locations in Class 1 and Class 2 open land 2014 survey units are as follows; 2015 2016

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-60 2017 Equation 5-135-8 2018

=

0.866 (for a triangular grid) or, 2019

=

(for a square grid) 2020 where:

2021 L =

grid spacing (dimension is square root of the area);

2022 A

=

the total area of the survey unit; and, 2023 N

=

the desired number of measurements.

2024 Once the grid spacing is established, a random starting point will be established for the survey pattern 2025 using a random number generator. Starting from this randomly-selected location, a row of points will 2026 then be established parallel to one of the survey unit axes at intervals of L. Additional rows will then be 2027 added parallel to the first row. For a triangular grid, additional rows will be added at a spacing of 2028 0.866L from the first row, with points on alternate rows spaced mid-way between the points from the 2029 previous row. For a square grid, points and rows will be spaced at intervals of L.

2030 The grid spacing may be rounded down for ease of locating sampling and measurement locations on the 2031 reference grid. The number of sampling and measurements locations identified will be counted to 2032 ensure the appropriate number of locations has been identified. Depending upon the configuration and 2033 layout of the survey unit and the starting grid location, the minimum number of sampling and 2034 measurement locations may not be identified. In this event, either a new random starting location will 2035 be specified or the grid spacing adjusted downward until the appropriate number of locations is reached.

2036 Software tools that accomplish the necessary grid spacing, including random starting points and 2037 triangular or square shape, may be employed during FSS design. When available, this software will be 2038 used with suitable mapping programs to determine coordinates for a GPS. The use of these tools will 2039 provide a reliable process for determining, locating and mapping measurement locations in open land 2040 areas separated by large distances and will be helpful during independent verification.

2041 For Class 3 survey units, each sampling and measurement location will be randomly selected using a 2042 random number generator.

2043 The systematic sampling and measurement locations within each survey unit will be clearly identified 2044 and documented for the purposes of reproducibility. Actual measurement locations will be marked and 2045 identified by tags, labels, flags, stakes, paint marks, GPS location, photographic record, or equivalent.

2046 5.5.4.6.5.6.4.6.

Investigation Process 2047 During the FSS, any areas of concern will be identified and investigated. This will include any areas as 2048 identified by the surveyor in real-time during the scanning of surface soils, any areas identified during 2049 post-processing and reviewing of scan survey data, and any results of soil or bulk material analyses that 2050 exceed the DCGL. Based on this review, the suspect areas will be addressed by further biased surveys 2051 and sampling as necessary. The applicable investigation levels are provided in Table 5-1320.

2052

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-61 Table 5-20 Investigation Levels 2053 Classification Scan Investigation Levels Direct Investigation Levels Class 1

>DCGLW or >MDCscan if MDCscan is greater than DCGLW>DCGLEMC

>DCGLW>DCGLEMC Class 2

>DCGLW or >MDCscan if MDCscan is greater than DCGLW

>DCGLW Class 3

>DCGLW or >MDCscan if MDCscan is greater than DCGLW

>0.5 DCGLW 5.5.4.6.1.5.6.4.6.1.

Remediation and Reclassification 2054 The DQO process will be used as appropriate to evaluate the reclassification/resurvey action if an 2055 investigation level is exceeded. In Class 1 survey units, any areas of elevated residual radioactivity 2056 above the DCGLEMC will be remediated to reduce the residual radioactivity to acceptable levels. If an 2057 area is remediated, then a RASS will be performed to ensure that the remediation was sufficient.

2058 If an individual FSS measurement (ISOCS for basements, sample for soil, and instrument reading for 2059 buried pipe) in a Class 2 survey unit exceeds the DCGLw, the survey unit, or portion of the survey unit 2060 will be investigated. The remediation action levels for embedded pipe and penetrations are discussed in 2061 section 5.5.6. If small areas of elevated activity exceeding the DCGLw are confirmed by this investigation 2062 or, if the investigation suggests that there may be a reasonable potential that contamination is present in 2063 excess of the DCGLw, then all or part of the survey unit will be reclassified as Class 1 and the survey 2064 strategy for that survey unit redesigned accordingly.

2065 If an individual survey measurement in a Class 3 survey unit exceeds 50 percent of the DCGLw, the 2066 survey unit, or portion of a survey unit, will be investigated. If the investigation confirms residual 2067 radioactivity in excess of 50 percent of the DCGLw, then the survey unit will be reclassified to a Class 1 2068 or a Class 2 survey unit and the survey re-designed and re-performed accordingly.

2069 Any areas of elevated residual radioactivity above the DCGLEMC will be remediated to reduce the 2070 residual radioactivity to acceptable levels.

2071 If an individual survey measurement (scan or direct) in a Class 2 survey unit exceeds the DCGLw, the 2072 survey unit, or portion of the survey unit, will be investigated, and if necessary, be reclassified to a 2073 Class 1 area and the survey re-designed and re-performed accordingly. If an individual survey 2074 measurement in a Class 3 survey unit exceeds 50 percent of the DCGLw, the survey unit, or portion of a 2075 survey unit, will be investigated, and if determined to exceed the DCGL, reclassified to a Class 1 or a 2076 Class 2 survey unit and the survey re-designed and re-performed accordingly. If the elevated survey 2077 measurement (>DCGL) is confirmed by investigation, but cannot be thoroughly described as an isolated 2078 condition, (i.e., it cannot be demonstrated with great certainty that this condition does not exist 2079 elsewhere in the survey unit) the survey unit will be reclassified. If the result cannot be duplicated, the 2080 population of the individual and average measurement results with respect to the DCGL will be 2081 reviewed, and if the variability does not suggest the initial classification was inappropriate, the survey 2082 unit will not be reclassified.

2083

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-62 Re-classification of a survey unit from a less restrictive classification to a more restrictive classification 2084 may be done without prior NRC approval. However, reclassification to a less restrictive classification 2085 requires prior NRC approval.

2086 5.5.4.6.2.5.6.4.6.2.

Resurvey 2087 If a survey unit is re-classified (in whole or in part), or if remediation is performed within a unit, then 2088 the affected areas are subject to re-survey.

2089 In a Class 1 survey unit. if the Elevated Radioactivity Fraction (fEMC) exceeds unity in 5% or less of the 2090 survey unit area, then additional FSS may not be needed to demonstrate compliance with the release 2091 criterion. The original FSS and the results of the post-remediation surveys may be sufficient. If the 2092 fEMC exceeds unity in greater than 5% of the survey unit area, then the entire survey unit will require a 2093 new FSS using a new survey design. Another consideration is whether the number of random 2094 measurement/sample locations affected by the remediation is less than the 20% margin added to the 2095 survey design. If the extent of the elevated area relative to the total area of the survey unit is significant, 2096 then the entire survey unit may require a new FSS using a new survey design.

2097 Any re-surveys will be designed and performed as specified in this plan based on the appropriate 2098 classification of the survey unit. That is, if a survey unit is re-classified or a new survey unit is created, 2099 the survey design will be based on the new classification.

2100 For example, a Class 2 area that is divided due to contamination identified in excess of the DCGLw will 2101 be divided into at least two areas (the original Class 2 survey unit plus one or more Class 1 survey 2102 units). If the original Class 2 survey design criteria has been satisfied for the original Class 2 survey 2103 unit, then no additional action is required. If the original Class 2 survey design criteria is not satisfied, 2104 then additional measurements will be obtained, as necessary, in the remaining portion of the original 2105 Class 2 survey unit to comply with the original survey design. The new sub-divided survey unit(s) will 2106 undergo FSS in accordance with the new classification.

2107 A Class 3 area that is divided due to contamination identified in excess of 50% of the DCGLw will be 2108 divided into at least two areas (the original Class 3 survey unit plus one or more Class 1 or Class 2 2109 survey units). If the original Class 3 survey design criteria has been satisfied for the original Class 3 2110 survey unit, then no additional action is required. If the original Class 3 survey design criteria is not 2111 satisfied, then additional measurements will be obtained, as necessary, in the remaining portion of the 2112 original Class 3 survey unit to comply with the original survey design. The new sub-divided survey 2113 unit(s) will undergo FSS in accordance with the new classification. For example, a Class 3 area that is 2114 subdivided due to the unexpected presence of radioactivity will be divided into at least two areas. One 2115 of these may remain as a Class 3 area while the other may be a Class 2 area. In order to maintain the 2116 survey design Type I and Type II decision error rates in the Class 3 area, additional measurements may 2117 be required to be performed at randomly selected locations until the required total number of 2118 measurements is met. The new sub-divided Class 2 survey area will then be surveyed using a new 2119 survey design. The Type I and II decision error rates used will be documented in the FSS report.

2120 A Class 2 area that is subdivided due to the levels of radioactivity identified will be divided into at least 2121 two areas as well. In this case if the original survey design criteria has been satisfied, no additional 2122 action is required, otherwise the remaining Class 2 survey unit will be redesigned. The new sub-2123 divided survey unit will be surveyed against a new survey design.

2124

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-63 If remediation is required in only a small area of a Class 1 survey unit, any replacement measurements 2125 or samples required will be made within the remediated area at randomly selected locations following 2126 verification that the remediation activities did not affect the remainder of the unit. Re-survey will be 2127 required in any area of a survey unit is affected by subsequent remediation activities. Additional 2128 guidance regarding the failure and re-survey of a survey unit and is provided in section 8.5.3 of 2129 MARSSIM.

2130 5.6.5.7.Final Status Survey Implementation 2131 Trained and qualified personnel will perform survey measurements and collect samples. FSS 2132 measurements include surface scans, static measurements, gamma spectroscopy of volumetric 2133 materials, and in-situ gamma spectroscopy. The surveying and sampling techniques are specified in 2134 approved procedures. At ZSRP, FSS implementation only pertains to the assessment of surface and 2135 subsurface soils as well as the inventory of any buried piping that will remain at site closure. The 2136 survey approach that will be used to quantify the remaining residual radioactivity in structures and the 2137 inventory of any embedded piping/penetrations that will remain at site closure is presented in 2138 section 5.5 of this FRS Plan.

2139 5.6.1.5.7.1.

Survey Methods 2140 The survey methods to be employed for FSS will consist of combinations of gamma scans and static 2141 measurements, soil and sediment sampling and in-situ gamma spectroscopy. Additional specialized 2142 methods may be identified as necessary between the time this plan is approved and the completion of 2143 FSS activities. Any new technologies will meet the applicable DQOs of this plan, and the technical 2144 approach will be documented for subsequent regulator review.

2145 5.6.1.1.5.7.1.1.

Scanning 2146 Scanning is performed in order to locate small, elevated areas of residual activity above the 2147 investigation level. It is the process by which a surveyor passes a portable radiation detector within 2148 close proximity of a surface with the intent of identifying residual radioactivity. Scan surveys that 2149 identify locations where the magnitude of the detector response exceeds an investigation level indicate 2150 that further investigation is warranted to determine the amount of residual radioactivity. The 2151 investigation levels may be based on the DCGLw, a fraction of the DCGLw, or the DCGLEMC, 2152 depending upon the detection capability (instrument and surveyor) to identify radioactivity.

2153 One of the most important elements of a scan survey is defining the limit of detection in terms of the a 2154 priori scanning MDC in order to gauge the ability of the field measurement system to confirm that the 2155 unit is properly classified, and to identify any areas where residual radioactivity levels are elevated 2156 relative to the DCGLw. If the scanning indicates that the survey unit or a portion of the survey unit has 2157 been improperly classified, then the survey design process must be evaluated to either assess the effect 2158 of reclassification on the survey unit as a whole (if the whole unit requires reclassification) or a new 2159 design must be established for the new unit(s) (in the case of sub-division). A new survey design will 2160 require a re-evaluation of the survey strategy to decide if it can meet the requirements of the revised 2161 survey design. If not, the survey strategy must be revised based on the available instrumentation and 2162 methods.

2163

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-64 Technicians will respond to indications of elevated areas while surveying. Upon detecting an increase 2164 in visual or audible response, the technician will reduce the scan speed or pause and attempt to isolate 2165 the elevated area. If the elevated activity is verified to exceed the established investigation level, the 2166 area will be bounded (e.g., marked and measured to obtain an estimated affected surface area).

2167 If surface conditions prevent scanning at the specified distance, the detection sensitivity for an alternate 2168 distance will be determined and the scanning technique adjusted accordingly. Whenever possible, 2169 surveyors will monitor the visual and audible responses to identify locations of elevated activity that 2170 require further investigation and/or evaluation.

2171 For the FSS of basement surfaces, the surface area covered by a single ISOCS measurement is large (a 2172 nominal range of 10-30 m2) which eliminates the need for traditional scan surveys.

2173 5.7.1.2.

Beta-Gamma Scanning 2174 Scanning is performed in order to locate small, elevated areas of residual activity above the 2175 investigation level. Miscellaneous materials may be scanned for beta-gamma radiation with appropriate 2176 instruments such as those listed in Table 5-21. The measurements will typically be performed at a 2177 distance of 1 cm or less from the surface and at a scan speed of 5 cm/sec for hand-held instruments.

2178 Adjustments to scan speed and distance may be made in accordance with approved procedures.

2179 5.6.1.2.5.7.1.3.

Volumetric Sampling 2180 Volumetric sampling is the process of collecting a portion of a media as a representation of the locally 2181 remaining media. The collected portion of the medium is then analyzed to determine the radionuclide 2182 concentration. Examples of materials that may be sampled include soil, sediments, concrete and 2183 groundwater for open land areas. Bulk material samples will be analyzed via gamma spectroscopy, 2184 alpha spectroscopy or liquid scintillation counting as appropriate.

2185 Trained and qualified individuals will collect and control samples. All sampling activities will be 2186 performed under approved procedures. ZSRP will utilize a chain-of-custody (COC) process to ensure 2187 sample integrity.

2188 Quality assurance (QA) requirements for FSS activities that apply to sample collection (e.g., split 2189 samples, duplicates, etc.) and onsite and offsite laboratories employed to analyze samples as a part of 2190 the FRS FSS process will be controlled by approved procedures, in conformance with the QAPP and is 2191 further described in section 5.9. Performance of laboratories will be verified periodically in accordance 2192 with the QAPP and ZS-QA-10, Quality Assurance Project Plan - Zion Station Restoration Project 2193 (Reference 5-1918).

2194 5.6.1.3.5.7.1.4.

Fixed Measurements 2195 Fixed measurements are taken by placing a detector at a defined distance above a surface, taking a 2196 discrete measurement for a pre-determined time interval, and recording the reading. Fixed 2197 measurements may be collected at random locations in a survey unit or may be collected at systematic 2198 locations and supplement scanning surveys for the identification of small areas of elevated activity.

2199 Fixed measurements may also be collected at locations identified by scanning surveys as part of an 2200 investigation to determine the source of the elevated instrument response. Professional judgment may 2201

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-65 also be used to identify locations for fixed measurements to further define the areal extent of 2202 contamination.

2203 5.6.1.4.5.7.1.5.

Surface Soils 2204 In this context, surface soil refers to outdoor areas where the soil is, for purposes of dose modeling, 2205 considered to be uniformly contaminated from the surface down to a depth of 15 cm (6 in). These areas 2206 will be surveyed through combinations of sampling, scanning, and in-situ measurements, as 2207 appropriate.

2208 5.6.1.4.1.5.7.1.5.1.

Gamma Scans of Surface Soils 2209 Gamma scans will be performed over open land surfaces to identify locations of residual surface 2210 activity. NaI gamma scintillation detectors (typically 2 x 2) will be used for these scans.

2211 ZionSolutions TSD #11-004 presents the response and scan MDC of the Ludlum Model 44-10 NaI 2212 detectors to Co-60 and Cs-137 radionuclides when used for scanning surface soils. Where appropriate, 2213 gamma emitters such as Co-60 and Cs-137 will be used as surrogates to infer the amount of any HTD 2214 radionuclide(s) that may be present in the distribution in accordance with section 5.2.46. In situ gamma 2215 spectroscopy may also be effectively substituted for scanning surveys. When this approach is used, the 2216 orientation of the detector, FOV, and a priori MDC will be documented and approved as a DQO during 2217 FSS design and survey package development.

2218 When using hand-held detectors, gamma scanning is generally performed by moving the detector in a 2219 serpentine pattern, usually within 15 cm (6 in) from the surface, while advancing at a rate of 2220 approximately 0.5 m (20 in) per second. Audible and visual signals will be monitored.

2221 Surveyors will respond to indications of elevated areas while surveying. Upon detecting an increase in 2222 visual or audible response, the surveyor will reduce the scan speed or pause and attempt to isolate the 2223 elevated area. If the elevated activity is verified to exceed the established investigation level, the area is 2224 bounded (e.g., marked or flagged and measured to obtain an estimated affected surface area).

2225 5.6.1.4.2.5.7.1.5.2.

Sampling of Surface Soils 2226 Samples of surface soil (including sediment or sludge) will be obtained from designated systematic 2227 locations and at areas of elevated activity identified by gamma scans. An appropriate volume of soil 2228 (typically 0.5-1 liter) will be collected at each sampling location using hand trowels, bucket augers, or 2229 other suitable sampling tools. A GPS reading will be obtained at each surface soil location and a pinned 2230 flag or similar marker will be placed in the ground to mark the location.

2231 Sample preparation includes removing extraneous material and homogenizing and drying the soil for 2232 analysis. Separate containers are used for each sample and each container is tracked through the 2233 analysis process using a chain-of-custody process.

2234 All surface soil samples taken during continuing characterization and FSS will be analyzed by gamma 2235 spectrometry. For continuing characterization, 10% of any surface soil samples taken in a survey unit 2236 will be analyzed for the initial suite of HTD radionuclides. For FSS, 10% of any surface soil samples 2237 taken in a survey unit will be analyzed for the dose significant HTD ROC.

2238

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-66 5.6.1.5.5.7.1.6.

Subsurface Soils 2239 Subsurface soil refers to soil that resides at a depth greater than 15 cm below the final configuration of 2240 the ground surface or soil that will remain beneath structures such as basement floors/foundations or 2241 pavement at the time of license termination.

2242 During site characterization, the HSA was consulted to identify those survey areas where the potential 2243 existed for subsurface radioactivity. Such areas included, but were not limited to, areas under buildings, 2244 building floors/foundations, or outside components where leakage was known or suspected to have 2245 occurred in the past and on-site storage areas where radioactive materials have been identified. Soil 2246 data from both the HSA and any pertinent surface characterization data were used to establish locations 2247 and potential depth for any potential sub-surface radioactivity. During site characterization, a total of 2248 eight-hundred seventy-one (871) composited subsurface soil samples were collected in impacted open 2249 land survey units to depths of approximately 3 meters below grade and analyzed for the potential ROC.

2250 To date, only Cs-137 and Co-60 have been identified at concentrations greater than the analytic MDC 2251 of the instrument used and no residual radioactivity was identified at concentrations greater than the 2252 generic screening values (DCGLw) from NUREG-1757, Appendix I for each of the potential ROC.

2253 During decommissioning of Zion, any subsurface soil contamination that is identified by continuing 2254 characterization or operational radiological surveys that is in excess of the site specific (DCGLw) for 2255 each of the potential ROC as presented in Table 5-2 will be remediated. The remediation process will 2256 include performing RASS of the open excavations in accordance with section 5.4.2 of this FRS FSS 2257 Plan. The RASS will include scan surveys and the collection of soil samples during excavation to 2258 gauge the effectiveness of remediation, and to identify locations requiring additional excavation. The 2259 scan surveys and the collection of and subsequent laboratory analysis of soil samples will be performed 2260 in a manner that is intended to meet the DQOs of FSS. The data obtained during the RASS is expected 2261 to provide a high degree of confidence that the excavation, or portion of the excavation, meets the 2262 criterion for the unrestricted release of open land survey units. Soil samples will be collected to depths 2263 at which there is high confidence that deeper samples will not result in higher concentrations.

2264 Alternatively, a NaI detector or intrinsic germanium detector of sufficient sensitivity to detect residual 2265 radioactivity at the DCGLw may be utilized to scan the exposed soils in an open excavation to identify 2266 the presence or absence of soil contamination, and the extent of such contamination.Alternatively, a NaI 2267 detector or intrinsic germanium detector of sufficient sensitivity to detect residual radioactivity at the 2268 DCGLw may be utilized to identify the presence or absence of subsurface contamination, and the extent 2269 of such contamination. If the detector identifies the presence of contamination at a significant fraction 2270 of the DCGLw, additional confirmatory investigation and analyses of soil samples of the suspect areas 2271 will be performed.

2272 5.6.1.5.1.5.7.1.6.1.

Scanning of Subsurface Soils during FSS 2273 Per NUREG-1757, scanning is not applicable to subsurface soils during the performance of FSS.

2274 Scanning will be performed during the RASS of excavations resulting from any remediation of 2275 subsurface soil contamination. The scanning of exposed subsurface soils during the RASS, where 2276 accessible as an excavated surface, will be used with the analysis of soil samples to demonstrate 2277 compliance with site release criteria.

2278

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-67 5.6.1.5.2.5.7.1.6.2.

Sampling of Subsurface Soils during FSS 2279 In accordance with NUREG-1757, Appendix G, if the HSA indicates that there is no likelihood of 2280 substantial subsurface residual radioactivity, subsurface surveys are not necessary. The HSA as well as 2281 the results of the extensive characterization of subsurface soils in the impacted area surrounding the 2282 Zion facility have shown that there is minimal residual radioactivity in subsurface soil. Consequently, 2283 Zion proposes to perform minimal subsurface sampling during FSS.

2284 In Class 1 open land survey units, a subsurface soil sample will be taken at 10% of the systematic 2285 surface soil sample locations in the survey unit with the location(s) selected at random. In addition, if 2286 during the performance of FSS, the analysis of a surface soil sample, or the results of a surface gamma 2287 scan indicates the potential presence of residual radioactivity at a concentration of 75% of the 2288 subsurface DCGLw, then additional biased subsurface soil sample(s) will be taken within the area of 2289 concern as part of the investigation.

2290 In Class 2 and Class 3 open land survey units, no subsurface soil sample(s) will be taken as part of the 2291 survey design. However, as with the Class 1 open land survey units, if during the performance of FSS, 2292 the analysis of a surface soil sample, or the results of a surface gamma scan indicates the potential 2293 presence of residual radioactivity at a concentration of 75% of the subsurface DCGLw, then biased 2294 subsurface soil sample(s) will be taken to the appropriate depth within the area of concern as part of the 2295 investigation.

2296 GeoProbe, split spoon sampling or other methods may be used to acquire subsurface soil samples.

2297 Subsurface soil samples will be obtained to a depth of at least 1 meter or refusal, whichever is reached 2298 first. In cases where refusal is met because of bedrock, the sample will be used as is. In cases where 2299 a non-bedrock refusal is met prior to the 1 meter depth, the available sample will be used to represent 2300 the 1 meter sample. If residual radioactivity is detected in the 1 meter sample, an additional meter of 2301 depth will be sampled and analyzed.

2302 Subsurface soil samples will be segmented and homogenized over each one-meter of depth. Extraneous 2303 material will be removed from each segment and the sample will be adequately dried. The material will 2304 then be placed into a clean sample container and properly labeled. All samples will be tracked from 2305 time of collection through the final analysis in accordance with procedure and survey package 2306 instructions.

2307 All subsurface soil samples taken during continuing characterization and FSS will be analyzed by 2308 gamma spectrometry. If gamma spectrometry analysis indicates the presence of plant-derived gamma 2309 emitting radionuclides at concentrations greater than the DCGLw, then the sample will also be analyzed 2310 for the potential presence of HTD ROC.

2311 5.6.1.5.3.5.7.1.6.3.

Sampling of Subsurface Soils below Structure Basement Foundations 2312 The foundation walls and basement floors below the 588 foot elevation of the Unit 1 Containment, 2313 Unit 2 Containment, Auxiliary Building, Turbine Building, Crib House/Forebay, WWTF and remnants 2314 of the SFP will remain at the time of license termination. Based on the results of subsurface soil 2315 sampling performed during site characterization, it is not likely that the residual radioactivity 2316 concentrations in soil beneath these building foundations exceed the site-specific (DCGLw) as presented 2317 in Table 5-55. However, prior to license termination, it will be necessary to ascertain the radiological 2318 conditions of these sub-slab soils to demonstrate suitability for unrestricted release.

2319

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-68 As stated in section 5.3.4.4, the soils under the basement concrete of the Containment Buildings, the 2320 Auxiliary Building and the SFP/Transfer Canal have been designated as continuing characterization 2321 areas once commodity removal and building demolition have progressed to a point where access can be 2322 achieved. Continuing characterization will consist of soil borings or use of GeoProbe technology at 2323 the nearest locations along the foundation walls that can be feasibly accessed. The under-basement soil 2324 activity will be determined by interpreting results from borings collected at the nearest locations.

2325 Locations selected for sampling will be biased to locations having a high potential for the accumulation 2326 and migration of radioactive contamination to sub-surface soil. Angled soil borings will also be 2327 performed to directly access the sub-slab soils. The exact number and location of the soil borings will 2328 be determined by DQO during the survey design. All samples taken from sub-slab soils will be 2329 analyzed by gamma spectrometry. Ten percent (10%) of any sub slab soil samples taken will be 2330 analyzed for the initial suite of HTD radionuclides.

2331 If possible, survey design will also consider the possibility of coring through the basement concrete 2332 floor slabs to facilitate the collection of soil samples. However, to date, this has been not possible due 2333 to the intrusion of groundwater into the basements through the bore hole. This is especially true for the 2334 Containment basements, as sampling through the foundation would require compromising the integrity 2335 of the internal steel liner. To address the issue of groundwater intrusion and still investigate the 2336 potential for migration of contamination from building interiors to the sub-foundation soils, the 2337 characterization will include deep cores in the concrete foundations/floor, but not fully through the 2338 foundation. This investigation will be performed in the Auxiliary Building, SFP/Transfer Canal and 2339 Containment. The cores will be biased to areas with higher potential of providing a pathway for 2340 migration of contamination to sub-foundation soil including stress cracks, floor and wall interfaces, and 2341 penetrations through walls and floors for piping. If the analysis of the deepest 0.5 inch puck from the 2342 core in the foundation does not contain detectable activity, then it will be assumed that the location was 2343 not a source of sub-foundation soil contamination. If activity is positively detected at the deepest point 2344 in the core, continuing the core to the soil under the foundation will be considered depending on the 2345 levels of activity identified and the potential for groundwater intrusion.

2346 If residual radioactivity is detected in subsurface soils adjacent to or under a basement surface, then the 2347 investigation will also include an assessment of the potential contamination of the exterior of the 2348 structure. A sample plan for the investigation will be created as specified by procedure and the plan and 2349 investigation results will be provided to NRC for evaluation. Based on the results of the investigation, 2350 ZSRP will assess the dose consequences of the subsurface soil contamination or will remediate as 2351 necessary.

2352 Samples of building basement sub-slab soils will be obtained by coring through concrete slabs and 2353 foundations to facilitate the collection of soil samples. Additionally, GeoProbe technology may be 2354 employed to access the sub-slab soils from outside of the building footprint by drilling at an angle under 2355 the building. Locations selected for sampling will be biased to locations having a high potential for the 2356 accumulation and migration of radioactive contamination to sub-surface soil. The biased locations for 2357 sub-slab soil and concrete assessment could include stress cracks, floor and wall interfaces, penetrations 2358 through walls and floors for piping, run-off from exterior walls, and leaks or spills in adjacent outside 2359 areas, etc. All samples taken from sub-slab soils will be analyzed by gamma spectrometry. If gamma 2360 spectrometry analysis indicates the presence of plant-derived gamma emitting radionuclides at 2361 concentrations greater than the DCGLw, then the sample will also be analyzed for the potential presence 2362 of HTD ROC.

2363

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-69 5.6.1.6.5.7.1.7.

Stored Reuse of Excavated Soils 2364 ZSRP will not stockpile and store excavated soil for reuse as backfill in basements. However, 2365 overburden soils may be excavated to expose buried components (e.g. concrete pads, buried pipe, 2366 buried conduit, etc) that will be removed and disposed of as waste or, to install a new buried system.

2367 In these cases, the overburden soil will be removed, the component will be removed or installed, and 2368 the overburden soil will be replaced back into the excavation. In these cases, a RA will be performed.

2369 T, the footprint of the excavation, and areas adjacent to the excavation where the soil will be staged, 2370 will be scanned prior to the excavation. In addition, periodic scans will be performed on the soil as it is 2371 excavated and the exposed surfaces of the excavated soil will be scanned after it is piled next to the 2372 excavation for reuse. Scanning will be performed in accordance with section 5.7.1.5.1. A soil sample 2373 will be acquired at any scan location that indicates activity in excess of 50% of the soil DCGL. Any 2374 soil confirmed as containing residual radioactivity at concentrations exceeding 50% of the soil DCGL 2375 will not be used to backfill the excavation and will be disposed of as waste.

2376 A RA is performed prior to introducing off-site material to ZSRP for use as backfill in a basement, or 2377 for any other use. The radiological assessmentRA will be performed at thethe borrow pit, landfill, or 2378 other location from where the material originated and will. The radiological assessment consists of a 2379 gamma scans and material sampling. Gamma scans are performed in situ, or by package (using a hand-2380 held instrument or through the use of a truck monitor). Soil samples of overburden soils will be 2381 analyzed by gamma spectroscopy.In several areas, clean overburden soils may be removed and 2382 stockpiled on site for use as backfill materials. Prior to reuse, excavated soil will be surveyed to 2383 determine its suitability. Any surface scanning or volumetric analyses made will be directly compared 2384 with the appropriate release criteria. Soils satisfying the criteria for unconditional release may be 2385 stockpiled for use as onsite backfill material. Soils with detectable plant-derived radioactivity at 2386 concentrations greater than background will not be used as backfill for building basements. These soils 2387 may be used to backfill excavation voids outside of the building basement footprints.

2388 Scanning requirements and soil sample frequency shall also be determined in accordance with the 2389 classification of the area where the soil had originated. Controls will be instituted to prevent mixing of 2390 soils from more restrictive survey area classifications (e.g., Class 2 material could be used in either 2391 Class 1 or 2 areas and Class 1 material could only be used in Class 1 areas.)

2392 5.6.1.7.5.7.1.8.

Pavement Covered Areas 2393 Paved surfaces that remain at the site following decommissioning activities will require surveys for 2394 residual radioactivity. Paved areas will be incorporated into the larger open land survey units in which 2395 they reside. This is appropriate as the pavement is outdoors where the exposure scenario is most similar 2396 to direct radiation from surface soil. Pavement will be released as a surface soil and surveyed 2397 accordingly in accordance with the classification of the open land survey unit in which it resides.

2398 Samples of the pavement will be acquired at each systematic sample location. The sample media will 2399 be pulverized, analyzed by gamma spectrometry and compared with the site-specific DCGLw for 2400 surface soil for each of the potential ROC. If pavement exhibits residual radioactivity in excess of the 2401 site-specific DCGLw for surface soil, then the pavement will be removed and disposed of as radioactive 2402 waste and the soil beneath will be investigated.

2403

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-70 5.6.1.8.5.7.1.9.

Buried Piping 2404 Designated sections of buried piping will be remediated in place and undergo FSS. The inventory of 2405 buried piping located below the 588 foot grade that will remain and be subjected to FSS is provided in 2406 TSD 14-016discussed in LTP Chapter 2, section 2.3.3.7 and presented in Table 2-27. Compliance with 2407 the DCGL values, as presented in Table 5-66, will be demonstrated by measurements of total surface 2408 contamination and/or the collection of sediment samples..

2409 The survey of buried pipe will be achieved in the same manner as described for the survey of embedded 2410 pipe as discussed in section 5.5.6. The radiological survey of pipe system interiors involves the 2411 insertion of appropriately sized detectors into the pipe interior by a simple push-pull methodology, 2412 whereby the position of the detector in the piping system can be easily determined in a reproducible 2413 manner.

2414 The detectors are configured in a fixed geometry relative to the surveyed surface, thus creating a 2415 situation where a defensible efficiency can be calculated. The detectors are then deployed into the 2416 actual pipe and timed measurements are acquired at intervals commensurate with the contamination 2417 potential of the pipe. A conservative area of detection is assumed for each pipe size. It is also 2418 conservatively assumed that any activity is uniformly distributed in the area of detection.

2419 A static measurement is acquired at a pre-determined interval for the areal coverage to be achieved.

2420 The measurement output represents the gamma activity in gross cpm for each foot of piping traversed.

2421 This measurement value in cpm is then converted to dpm using the efficiency of the detector. The total 2422 activity in dpm is then adjusted for the assumed total effective surface area commensurate with the pipe 2423 diameter, resulting in measurement results in units of dpm/100 cm2. A surrogate correction based upon 2424 the radionuclide distribution present in the pipe is then applied to the gamma emission to account for 2425 the presence of other non-gamma emitting radionuclides in the mixture. This measurement result 2426 represents a commensurate and conservative gross measurement that can be compared to the buried 2427 pipe DCGLs.

2428 The acquisition of direct measurements using pipe-crawling technology and/or in-situ gamma-2429 spectroscopy may be utilized provided adequate instrument efficiencies and detection limits can be 2430 achieved. If necessary, scaling factors may be applied to establish gross radioactivity levels via 2431 radionuclide-specific measurements or other assessments, as appropriate. Radiological evaluations for 2432 piping or drains that cannot be accessed directly will be performed via measurements made at traps and 2433 other appropriate access points where the radioactivity levels are deemed to either bound or be 2434 representative of the interior surface radioactivity levels providing that the conditions within the balance 2435 of the piping can be reasonably inferred based on those data.

2436 5.6.1.9.5.7.1.10.

Groundwater 2437 Assessments of any residual radioactivity in groundwater at the site will be via groundwater monitoring 2438 wells installed at ZNPS. Ongoing monitoring of surface water and groundwater at ZNPS include 2439 REMP, Radiological Groundwater Protection Program (RGPP) and NPDES Monitoring. This is further 2440 described in Chapter 2, section 2.3.6.4.

2441

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-71 5.6.1.10.5.7.1.11.

Sediments and Surface Water 2442 Sediments will be assessed by collecting samples within locations of surface water ingress or by 2443 collecting composite samples of bottom sediments, as appropriate. Such samples will be collected 2444 using approved procedures based on accepted methods for sampling of this nature.

2445 Sediment samples will be evaluated against the site-specific soil DCGLs for each of the potential ROC 2446 as presented in Table 5-44. Assessment of residual radioactivity levels in surface water drainage 2447 systems will be via sampling of sediments, total surface contamination measurements, or both, as 2448 appropriate, making measurements at traps and other appropriate access points where radioactivity 2449 levels should be representative or bound those on the interior surfaces.

2450 5.6.1.11.5.7.1.12.

Survey Considerations for Buildings, Structures and Equipment 2451 All above grade buildings will be removed in the end-state for ZSRP. The survey approach that will be 2452 used to radiologically assess the residual radioactivity in below-grade basement surfaces is presented in 2453 section 5.5 of this FSS Plan. The FSS of minor solid structures, such as but not limited to the 2454 Switchyard, the microwave tower, and the Sewage Lift Station, telephone poles, fencing, culverts, valve 2455 boxesduct banks and electrical conduit will be included in the open land FSS unit in which they reside.

2456 These items will be scanned in accordance with recommended survey coverage in Table 5-19 using the 2457 site unconditional release criteria. Static measurements for total surface contamination and removable 2458 surface contamination (smears) primarily apply to the radiological assessment of solid media such as 2459 structures, systems and/or equipment.

2460 Prior to demolition, the standing concrete surface(s) (designated by process knowledge and previous 2461 characterization results as a suitable candidate(s) for potential use as clean fill) will be surveyed using 2462 the site program for unconditional release of material offsite. The unconditional release surveys will 2463 meet the statistical rigor and quality of a MARSSIM FSS. Once the concrete has been determined to be 2464 suitable for unconditional release, the structure will be demolished, all metal removed and the concrete 2465 crushed to pieces that are 10 inches in diameter or less. The material will then be stockpiled and 2466 controlled as non-radioactive clean fill (as per section 5.6.3) until such time that it is placed in the 2467 basement void. If the unconditional release surveys positively detect plant-derived radionuclides in any 2468 concentration, then the concrete will not be used as clean fill. In this case, it will be segregated, 2469 packaged and disposed of as low level radioactive waste. The results of static measurements taken 2470 during the unconditional release surveys will be provided to NRC in a Final Report.no detectable above 2471 background.suitable of unconditional releaseno detectable radiation above backgroundAt ZSRP, the 2472 BFM will be used to calculate the remaining total concentration of residual activity remaining in the 2473 subsurface concrete structures and the corresponding dose to groundwater. Consequently, these 2474 structures will not be subjected to FSS as defined by MARSSIM. The survey approach that will be 2475 used to radiologically assess the residual radioactivity in these structures is presented in section 5.5 of 2476 this FRS Plan.

2477 5.7.5.8.Final Status Survey Instrumentation 2478 Radiation detection and measurement instrumentation for performing FSS is selected to provide both 2479 reliable operation and adequate sensitivity to detect the ROC identified at the site at levels sufficiently 2480 below the DCGLw. Detector selection is based on detection sensitivity, operating characteristics and 2481 expected performance in the field.

2482

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-72 The DQO process includes the selection of instrumentation appropriate for the type of measurement to 2483 be performed (i.e., scan, static measurement) that are calibrated to respond to a radiation field under 2484 controlled circumstances; evaluated periodically for adequate performance to established quality 2485 standards; and sensitive enough to detect the ROC with a sufficient degree of confidence.

2486 When possible, instrumentation selection will be made to identify the ROC at levels sufficiently below 2487 the DCGLw. Detector selection will be based upon detection sensitivity, operating characteristics, and 2488 expected performance in the field. The instrumentation will, to the extent practicable, use data logging 2489 to automatically record measurements to minimize transcription errors. Commercially available 2490 portable and laboratory instruments and detectors are typically used to perform the three basic survey 2491 measurements: 1) surface scanning; 2) static measurements; and 3) radionuclide specific analysis of 2492 media samples such as soil and other bulk materials.

2493 Specific implementing procedures will control the issuance, use, and calibration of instrumentation used 2494 for FSS. The specific DQOs for instruments are established early in the planning phase for FSS 2495 activities, implemented by standard operating procedures (SOP) and executed in the survey plan.

2496 Further discussion of the DQOs for instruments is provided below.

2497 5.7.1.5.8.1.

Instrument Selection 2498 The selection and proper use of appropriate instruments for both total surface contamination 2499 measurements and laboratory analyses is one of the most important factors in assuring that a survey 2500 accurately determines the radiological status of a survey unit and meets the survey objectives. The 2501 survey plan design must establish acceptable measurement techniques for scanning and direct 2502 measurements. The DQO process must include consideration as to the type of radiation, energy 2503 spectrum and spatial distribution of radioactivity as well as the characteristics of the medium to be 2504 surveyed.

2505 Radiation detection and measurement instrumentation will be selected based on the type and quantity of 2506 radiation to be measured. For direct measurements and sample analyses, MDCs less than 10% of the 2507 DCGL are preferable while MDCs up to 50% of the DCGL are acceptable.The target MDC for 2508 measurements obtained using field instruments will be 50 percent of the applicable DCGLw.

2509 Instruments used for scan measurements in Class 1 areas are required to be capable of detecting 2510 radioactive material at the DCGLEMC. The target MDC for measurements obtained using laboratory 2511 instruments will be 10 percent of the applicable DCGLw. Measurement results with associated MDC 2512 that exceed these values may be accepted as valid data after evaluation by health physics supervision.

2513 The evaluation will consider the actual MDC, the reported value for the measurement result, the 2514 reported uncertainty and the fraction of the DCGL identified in the sample.

2515 Other measurement instruments or techniques may be utilized. The acceptability of additional or 2516 alternate instruments or technologies for use in the FSS will be justified in a technical basis evaluation 2517 document prior to use. Technical basis evaluations for alternate final status survey instruments or 2518 techniques will be provided for NRC review 30 days prior to use. This evaluation will include the 2519 following:

2520

  • Description of the conditions under which the method would be used; 2521
  • Description of the measurement method, instrumentation and criteria; 2522

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-73

  • Justification that the technique would provide the required sensitivity for the given survey unit 2523 classification; and, 2524
  • Demonstration that the instrument provides sufficient sensitivity for measurement.

2525 Instrumentation currently proposed for use in the FSS is listed in Table 5-1421. Instrument MDCs are 2526 discussed in section 5.8.4 and nominal MDC values for the proposed instrumentation are presented in 2527 Table 5-1522.

2528 2529 5.7.2.5.8.2.

Calibration and Maintenance 2530 Instruments and detectors will be calibrated for the radiation types and energies of interest or to a 2531 conservative energy source. Instrument calibrations will be documented with calibration certificates 2532 and/or forms and maintained with the instrumentation and project records. Calibration labels will also 2533 be attached to all portable survey instruments. Prior to using any survey instrument, the current 2534 calibration will be verified and all operational checks will be performed.

2535 Instrumentation used for final status surveys will be calibrated and maintained in accordance with 2536 approved ZionSolutions site calibration procedures. Radioactive sources used for calibration will be 2537 traceable to the NIST and have been obtained in standard geometries to match the type of samples being 2538 counted. When a characterized high-purity germanium (HPGe) detector is used, suitable NIST-2539 traceable sources will be used for calibration, and the software set up appropriately for the desired 2540

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-74 Table 5-21 Typical FSS Survey Instrumentation 2541 Measurement Type Detector Type Effective Detector Area & Window Density Instrument Model Detector Model Beta Static/Scan Measurement Gas-Flow Proportional 126 cm2 0.8 mg/cm2 Aluminized Mylar Ludlum 2350-1 Ludlum 43-68 Beta Static/Scan Measurement Scintillation 1.2 mg/cm2 0.01 Plastic Scintillation 125 cm2 Ludlum 2350-1 Ludlum 44-116 Beta Scan Measurement Gas-Flow Proportional 584 cm2 0.8 mg/cm2 Aluminized Mylar Ludlum 2350-1 Ludlum 43-37 Gamma Scan Measurement Scintillation 2 diameter x 2 length NaI Ludlum 2350-1 Ludlum 44-10 Gamma Static/Scan Measurement High-purity Germanium N/A Canberra In Situ Object Counting System (ISOCS)

Gamma Pipe Static Measurement CsI NaI NaI 0.75 x 0.75 2 x 2 3 x 3 Ludlum 2350-1 Ludlum 44-159 Ludlum 44-157 Ludlum 44-162 Surface and Volumetric Material (soil, etc.)

High-purity Germanium N/A Canberra Lab or In Situ Detector N/A 2542

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-75 Table 5-22 Typical FSS Instrument Detection Sensitivities 2543 Instruments and Detectors a Radiation

Background

Count Time (minutes)

Typical

Background

(cpm)

Typical Instrument Efficiency b (t)

Count Time (minutes)

Static MDC (dpm/100 cm2)

Scan MDC Model 43-68 Beta-Gamma 1.0 300 0.258 1.0 256 612 c Model 44-116 Beta 1.0 200 0.124 1.0 539 1990 c Model 43-51 Beta 1.0 40 0.126 810 2782 c Model 43-37 Beta-Gamma 1.0 1,200 0.236 1.0 119 372 c Model 44-10 Gamma 1.0 8,000 N/A 0.02 N/A 5.2 pCi/g d ISOCS Gamma Up to 60 N/A 60% relative 5-60 10% of the DCGL (pCi/m2)

N/A Model 44-159 e Gamma 1.0 700 0.024 1

5,250 N/A Model 44-157 e Gamma 1.0 6,300 0.212 1

1,750 N/A Model 44-162 e Gamma 1.0 16,000 0.510 1

1,150 N/A a Detector models listed are used with the Ludlum 2350-1 Data Logger 2544 bTypical calibration source used is Cs-137. The efficiency is determined by counting the source with the detector in a fixed position from the source 2545 (reproducible geometry). The t value is based on ISO-7503-1 and conditions noted for each detector.

2546 cScan MDC, in dpm/100 cm2, for the 43-68 was calculated assuming a scan rate of 5.08 cm/sec, which is equivalent to a count time of 1.73 seconds (0.028 2547 minutes) using a detector width of 8.8 cm. The 43-37 detector assumes a scan rate of 12.7 cm/s and results in a count time of 1.05 seconds (0.018 minutes) for a 2548 detector width of 13.34 cm. The 44-116 detector width is 2.54 cm and results in a count time of 1.00 seconds at 2.54 cm/s scan speed.

2549 dScan MDC in pCi/g is calculated using the approach described in section 6.7.2.1 of MARSSIM for a Cs-137 nuclide fraction of 0.95 and a Co-60 fraction of 2550 0.05 with a determined detector sensitivity of 1000 and 430 cpm per uR/hr for each radionuclide respectively. The weighted MicroShield-determined 2551 conversion factor was 0.282 pCi/g per uR/hr.

2552 eThe efficiency varies for the pipe detectors depending on the pipe diameter used. The efficiency used for the table is the averaged efficiency value for the pipe 2553 diameters. The detectors and diameters are: model 44-159: 2-4 in. dia., model 44-157: 4-8 in. dia., model 44-162: 8-12 in. dia.

2554

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-76 geometry. If vendor services are used, these will be obtained in accordance with purchasing 2555 requirements for quality related services, to ensure the same level of quality.

2556 5.7.3.5.8.3.

Response Checks 2557 Prior to use on-site, all project instrument calibrations will be verified and initial response data 2558 collected. These initial measurements will be used to establish performance standards (response 2559 ranges) in which the instruments will be tested against on a daily basis when in use. An acceptable 2560 response for field instrumentation is an instrument reading within +/-20% of the established check source 2561 value. Laboratory instrumentation standards will be within +/-3 sigma as documented on a control chart.

2562 Instrumentation will be response checked in accordance with ZionSolutions procedures for 2563 instrumentation use. Response checks will be performed daily before instrument use and again at the 2564 end of use. The check sources used for response checks will emit the same type of radiation as that 2565 being measured in the field and will be held in fixed geometry jigs for reproducibility. If the instrument 2566 response does not fall within the established range, the instrument will be removed from use until the 2567 reason for the deviation can be resolved and acceptable response again demonstrated. If the instrument 2568 fails a post-survey source check, all data collected during that time period with the instrument will be 2569 carefully reviewed and possibly adjusted or discarded, depending on the cause of the failure. In the 2570 event that data areis discarded, replacement data will be collected at the original locations.

2571 5.7.4.5.8.4.

Measurement Sensitivity 2572 The measurement sensitivity or MDC will be determined a priori for the instruments and techniques 2573 that will be used for FSS. The MDC is defined as the a priori activity level that a specific instrument 2574 and technique can be expected to detect 95% of the time. When stating the detection capability of an 2575 instrument, this value should be used. The MDC is the detection limit, (LD), multiplied by an 2576 appropriate conversion factor to give units of activity. The critical level, (LC), is the lower bound on 2577 the 95% detection interval defined for LD and is the level at which there is a 5% chance of calling a 2578 background value greater than background. This is the value used when actually counting samples or 2579 making direct radiation measurements. Any response above this level should be considered as above 2580 background (i.e., a net positive result). This will ensure 95% detection capability for LD. MDC is 2581 defined as the smallest amount or concentration of radioactive material that will yield a net positive 2582 count with a 5% probability of falsely interpreting background responses as true activity from 2583 contamination and a 5% probability of interpreting a result at the MDC level as being background. The 2584 MDC is dependent upon the counting time, geometry, sample size, detector efficiency and background 2585 count rate.

2586 5.7.4.1.5.8.4.1.

Total Efficiency 2587 Instrument efficiencies (i) for surface measurements are derived from the surface emission rate of the 2588 radioactive source(s) used during the instrument calibration. Total efficiency (t) is calculated by 2589 multiplying the instrument efficiency (i) by the surface efficiency (s) commensurate with the 2590 radionuclides alpha or beta energy using the guidance provided in ISO 7503-1, Evaluation of surface 2591 contamination - Part 1: Beta-emitters (maximum beta energy greater than 0.15 MeV) and alpha-2592 emitters (Reference 5-202019).

2593

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-77 5.7.4.2.5.8.4.2.

Static Minimum Detectable Concentration 2594 For static (direct) surface measurements with conventional detectors, such as those listed in Table 5-2595 1421, the MDC is calculated using the following equation:

2596 Equation 5-145-9 2597

=

2.713.0

+ 3.29

+

1002 2598 where:

2599 MDCstatic

=

Minimum Detectable Concentration in dpm/100cm2; 2600 ts

=

sample count time, 2601 tb

=

background count time, 2602 Rb

=

background count rate (cpm),

2603 t

=

total efficiency, and 2604 A

=

detector window area (cm2).

2605 2606 5.7.4.3.5.8.4.3.

Beta-Gamma Scan Measurement Minimum Detectable Concentration 2607 Following the guidance of sections 6.7 and 6.8 of NUREG-1507, MDCs for surface scans of surfaces 2608 for beta and gamma emitters will be computed in accordance with the following equation. For 2609 determining scan MDCs, a rate of 95% of correct detections is required and a rate of 60% of false 2610 positives is determined to be acceptable. Consequently, a sensitivity index value of 1.38 was selected 2611 from Table 6.1 of NUREG-1507. The formula used to determine the scanning MDC at the 2612 95% confidence level is:

2613 2614 2615 2616 Equation 5-155-10 2617

=

x 60

100 2618 where:

2619 MDCscan

=

Minimum Detectable Concentration in dpm/100cm2; 2620 d'

=

index of sensitivity (1.38),

2621 i

=

observation interval (seconds),

2622 bi

=

background counts per observation interval, 2623 t

=

total efficiency, 2624 p

=

surveyor efficiency (0.5), and 2625 A

=

detector window area (cm2).

2626

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-78 The numerator in the beta-gamma scan MDC equation represents the Minimum Detectable Count Rate 2627 (MDCR) that the observer would "seeobserve" at the performance level represented by the sensitivity 2628 index. The surveyor efficiency (p) variable is set at 0.5, as recommended by section 6.7.1 of NUREG-2629 1507. The factor of 100 corrects for probe areas that are not 100 cm2. The observation interval (i) is 2630 considered to be the amount of time required for the detector field of view to pass over the area of 2631 concern. This time depends upon the scan speed, the size of the source, and the fraction of the 2632 detectors sensitive area that passes over the source. The scan speed is based on one detector window 2633 width per second however; other scan speeds may be used. For the Ludlum Model 43-68 gas flow 2634 proportional detector, the window width is 8.8 cm resulting in a scan speed of ~3.5 inches per second.

2635 The floor monitor detector is the Ludlum Model 43-37 with a window width of 13.35 cm which results 2636 in a scan speed of 5.25 inches per second. The source efficiency term (s) may be adjusted to account 2637 for effects such as self-absorption, using the values found in Tables 2 and 3 in ISO 7503-1.

2638 5.7.4.4.5.8.4.4.

Gamma Scan Measurement Minimum Detectable Concentration 2639 In addition to the MDCR and detector characteristics, the scan MDC (in pCi/g) for land areas is based 2640 on the areal extent of the hot spot, depth of the hot spot, and the radionuclide (i.e., energy and yield of 2641 gamma emissions). If one assumes constant parameters for each of the above variables, with the 2642 exception of the specific radionuclide in question, the scan MDC may be reduced to a function of the 2643 radionuclide alone.

2644 The evaluation of open land areas requires a detection methodology of sufficient sensitivity for the 2645 identification of small areas of potentially elevated activity. Scanning measurements are performed by 2646 passing a hand-held detector, typically 2" x 2" NaI gamma scintillation detector, in gross count rate 2647 mode across the land surface under investigation. The centerline of the detector is maintained at a 2648 source-to-detector distance within 15 cm (6 in) and moved from side to side in a 1-meter wide pattern at 2649 a rate of 0.5 m/sec. This serpentine scan pattern is designed to cross each survey cell (one square 2650 meter) five times in approximately ten seconds. The audible and visuals signals are monitored for 2651 detectable increases in count rate. An observed count rate increase results in further investigation to 2652 verify findings and define the level and extent of residual radioactivity.

2653 An a priori determination of scanning sensitivity is performed to ensure that the measurement system is 2654 able to detect concentrations of radioactivity at levels below the regulatory release limit. Expressed in 2655 terms of scan MDC, this sensitivity is the lowest concentration of radioactivity for a given background 2656 that the measurement system is able to detect at a specified performance level and surveyor efficiency.

2657 This method represents the surface scanning process for land areas defined in NUREG-1507 and is the 2658 basis for calculation of the scanning detection sensitivity (scan MDC). The gamma scan MDC is 2659 discussed in detail in ZionSolutions TSD 11-004, which examines the gamma sensitivity for 5.08 by 2660 5.08 cm (2 x 2) NaI detectors to several radionuclide mixtures of Co-60 and Cs-137 using sand (SiO2) 2661 as the soil base. TSD 11-004 derives the MDC for the radionuclide mixtures at various detector 2662 distances and scan speeds. The model in TSD 11-004 uses essentially the same geometry configuration 2663 as the model used in MARSSIM. TSD 11-004 provides MDC values for the expected ZSRP soil 2664 mixture based on detector background condition, scan speed, soil depth (15 cm), soil density 2665 (1.6 g/cm3) and detector distance to the suspect surface.

2666

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-79 5.7.4.5.5.8.4.5.

HPGe Spectrometer Analysis 2667 The onsite ZionSolutions laboratory maintains gamma isotopic spectrometers that are calibrated to 2668 various sample geometries, including a one-liter marinelli geometry for soil analysis. The geometries 2669 are created using the Canberra LABSOCS software. These systems are calibrated using a NIST-2670 traceable mixed gamma source. On-site laboratory counting systems are set to meet a maximum MDC 2671 of 0.15 pCi/g for Cs-137 in soil; this is calculated in accordance with the following equation:

2672 2673 Equation 5-1116 2674

(

)= 3 + 4.65 x x 2675 where:

2676 B

=

number of background counts during the count interval t; 2677 K

=

proportionality constant that relates the detector response to the 2678 activity level in a sample for a given set of measurement 2679 conditions, 2680 V

=

mass of sample (g), and 2681 t

=

count time (minutes).

2682 5.7.4.6.5.8.4.6.

Pipe Survey Instrumentation 2683 Designated sections of embedded and buried piping will be remediated in place, if necessary, and 2684 undergo FSS. The inventory of buried piping located below the 588 foot grade that will remain and be 2685 subjected to FSS is discussed in Section 2.3.3.7 and presented in Table 2-27. The remaining buried 2686 pipe will be surveyed to ensure that the remaining residual radioactivity is less than the DCGLs derived 2687 for the unrestricted release of buried pipe as presented in Table 5-6. Pipe survey instruments proposed 2688 for use with pipe having diameters between 0.75 and 18 inches have been shown to have efficiencies 2689 ranging from approximately 0.02 to 0.5. This equates to detection sensitivities of approximately 2690 350 dpm/100 cm2 to 5,200 dpm/100 cm2. This level of sensitivity is adequate to detect residual 2691 radioactivity below the DCGLs derived for the unrestricted release of buried pipe as presented in 2692 Table 5-66.

2693 5.8.5.9.Quality Assurance 2694 ZionSolutions is responsible for the overall execution of the ZSRP. As the licensee, ZionSolutions is 2695 responsible for all licensing activities, safety, radiation protection, environmental safety and health, 2696 engineering and design, quality assurance, construction management, environmental management, 2697 waste management and financial management. ZionSolutions interfaces directly with the NRC and 2698 other stakeholders on all issues pertaining to decommissioning project activities at Zion.

2699 ZionSolutions has developed and is implementing a comprehensive QA Program to assure conformance 2700 with established regulatory requirements. The quality requirements and quality concepts are presented 2701 in ZS-QA-10 which adequately encompasses all risk-significant decommissioning activities. The 2702 participants in the ZionSolutions QA Program assure that the design, procurement, construction, testing, 2703

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-80 operation, maintenance, repair, modification, dismantlement and remediation of nuclear reactor 2704 components are performed in a safe and effective manner.

2705 The ZionSolutions QA Program complies with the requirements set forth in Appendix B of 10 CFR 50, 2706 Appendix H of 10 CFR 71, Appendix G of 10 CFR 72. References to specific industry standards for 2707 QA and QC measures governing FRS FSS activities are reflected in the QAPP as well as all applicable 2708 supporting procedures, plans, and instructions. Effective implementation of QA and QC measures will 2709 be verified through audit activities, with corrective actions being prescribed, implemented and verified 2710 in the event any deficiencies are identified. These measures will also apply to the any FRS FSS related 2711 services provided by off-site vendors, in addition to on-site sub-contractors.

2712 The QAPP has been prepared to ensure the adequacy of data being developed and used during FRSFSS.

2713 It supplements the quality requirements and quality concepts presented in ZS-QA-10. Compliance with 2714 the QAPP will serve to ensure that FRS FSS surveys are performed by trained individuals using 2715 approved written procedures and properly calibrated instruments that are sensitive to the suspected 2716 ROC. In addition, QC measures will be taken to obtain quantitative information to demonstrate that 2717 measurement results have the required precision and are sufficiently free of errors to accurately 2718 represent the area being investigated. QC checks will be performed as prescribed by the QAPP for both 2719 field measurements and laboratory analysis. Effective implementation of FRS FSS operations will be 2720 verified through audit and surveillance activities, including field walk-downs by 2721 Characterization/License Termination group management and program self-assessments, as appropriate.

2722 Corrective actions will be prescribed, implemented, and verified in the event any deficiencies are 2723 identified. These measures will apply to any applicable services provided by off-site vendors, as well 2724 as on-site sub-contractors.

2725 5.8.1.5.9.1.

Project Management and Organization 2726 ZionSolutions has established the Characterization/License Termination Group (within the Radiation 2727 Protection and Environmental organization) with sufficient management and technical resources to 2728 fulfill project objectives and goals. The Characterization/License Termination Group is responsible for:

2729

  • Site characterization; 2730
  • LTP development and implementation; and, 2731
  • The performance of FRSFSS.

2732 Characterization and FRS FSS encompasses all survey and sampling activities related to the LTP. This 2733 includes site characterization surveys, RASS, RA, STS and FSS. The duties and responsibilities of key 2734 ZionSolutions managers as well as the various key positions within the Characterization/License 2735 Termination Group are provided in section 2.3 of the QAPP. Responsibilities for each of the positions 2736 described may be assigned to a designee as appropriate. An organizational chart is provided as 2737 Figure 5-1.

2738 5.8.2.5.9.2.

Quality Objectives and Measurement Criteria 2739 The QA objectives for FRS FSS is to ensure the survey data collected are of the type and quality needed 2740 to demonstrate, with sufficient confidence, that the site is suitable for unrestricted release. The 2741 objective is met through use of the DQO process for FRS FSS design, analysis and evaluation.

2742 Compliance with the QAPP ensures that the following items are accomplished:

2743

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-81

  • The elements of the FRS FSS plan are implemented in accordance with the approved procedures, 2744
  • Surveys are conducted by trained personnel using calibrated instrumentation, 2745
  • The quality of the data collected is adequate, 2746
  • All phases of package design and survey are properly reviewed, with QC and management oversight 2747 provided, and 2748
  • Corrective actions, when identified, are implemented in a timely manner and are determined to be 2749 effective.

2750 The following describe the basic elements of the QAPP.

2751 5.8.2.1.5.9.2.1.

Written Procedures 2752 Sampling and survey tasks will be performed properly and consistently in order to assure the quality of 2753 FRS FSS results. The measurements will be performed in accordance with approved, written 2754 procedures. Approved procedures describe the methods and techniques used for FRS FSS 2755 measurements.

2756 5.8.2.2.5.9.2.2.

Training and Qualifications 2757 Personnel performing FRS FSS measurements will be trained and qualified. Training will include the 2758 following topics:

2759

  • Procedures governing the conduct of the FRSFSS, 2760
  • Operation of field and laboratory instrumentation used in the FRSFSS, and 2761
  • Collection of FSS and STS measurements and samples.

2762 Qualification is obtained upon satisfactory demonstration of proficiency in implementation of 2763 procedural requirements. The extent of training and qualification will be commensurate with the 2764 education, experience and proficiency of the individual and the scope, complexity and nature of the 2765 activity required to be performed by that individual. Records of training and qualification will be 2766 maintained in accordance with approved training procedures.

2767 5.8.2.3.5.9.2.3.

Measurement and Data Acquisitions 2768 The FRS FSS records will be designated as quality documents and will be governed by site quality 2769 programs and procedures. Generation, handling and storage of the original FRS FSS design and data 2770 packages will be controlled by site procedures. Each FRS FSS measurement will be identified by 2771 individual, date, instrument, location, type of measurement, and mode of operation.

2772 5.8.2.4.5.9.2.4.

Instrument Selection, Calibration and Operation 2773 Proper selection and use of instrumentation will ensure that sensitivities are sufficient to detect 2774 radionuclides at the required a priori MDC as well as assure the validity of the survey data. Instrument 2775 calibration will be performed with NIST traceable sources using approved procedures. Issuance, 2776 control and operation of the survey instruments will be conducted in accordance with the approved 2777 procedures.

2778

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-82 5.8.2.5.5.9.2.5.

Chain of Custody 2779 Responsibility for custody of samples from the point of collection through the determination of the FRS 2780 FSS results is established by procedure. When custody is transferred outside of the organization, a CoC 2781 form will accompany the sample for tracking purposes. Secure storage will be provided for archived 2782 samples.

2783 5.8.2.6.5.9.2.6.

Control of Consumables 2784 In order to ensure the quality of data obtained from FRS FSS surveys and samples, new sample 2785 containers will be used for each sample taken. Tools used to collect samples will be cleaned to remove 2786 contamination prior to taking additional samples. Tools will be decontaminated after each sample 2787 collection and surveyed for contamination.

2788 5.8.2.7.5.9.2.7. Control of Vendor-Supplied Services 2789 Vendor-supplied services, such as instrument calibration and laboratory sample analysis, will be 2790 procured from appropriate vendors in accordance with approved quality and procurement procedures.

2791 5.8.2.8.5.9.2.8.

Database Control 2792 Software used for data reduction, storage or evaluation will be fully documented. The software will be 2793 tested and validated prior to use by an appropriate test data set.

2794 5.8.2.9.5.9.2.9.

Data Management 2795 Survey data control from the time of collection through evaluation will be specified by procedure and 2796 survey package instructions. Manual data entries will be verified by a second individual.

2797 5.8.3.5.9.3.

Measurement/Data Acquisition 2798 QC surveys and samples will be performed primarily as verification that the original FRS FSS results 2799 are valid. QC surveys may include replicate surveys, field blanks and spiked samples, split samples, 2800 third party analysis and sample recounts. Replicate surveys apply to scan and static direct 2801 measurements. Field blanks and sample recounts apply to loose surface and material sampling surveys.

2802 Spiked samples and split samples apply to material sampling surveys. Third party analysis applies to 2803 material samples counted by a different laboratory than normally used. QC survey results will be 2804 evaluated and compared to the original FRS FSS survey results in accordance with the appropriate 2805 acceptance criteria.

2806 5.8.3.1.5.9.3.1.

Replicate Measurements and Surveys 2807 Replicate measurements will be performed on 5% of the static and scan locations in each applicable 2808 FSS or STS survey package in locations chosen at random. QC replicate surveys, conducted during the 2809 FSS or STS, will be performed at a frequency of one per every twenty packages designed.

2810 Replicate static and scan measurement results will be compared to the original measurement results to 2811 determine if the acceptance criteria are met. The acceptance criteria for static measurements and scan 2812 surveys are that the same conclusion is reached for each survey unit and no other locations, greater than 2813 the scan investigation level for the area classification, are found. If the same conclusion is not reached 2814

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-83 or any exceptions are reported that were not reported in the original survey, further evaluations will be 2815 performed.

2816 The acceptance criteria for QC replicate surveys is that both data sets either pass or fail the appropriate 2817 statistical test (i.e. Sign Test or WRS test) for that survey unit. Agreement is ultimately determined that 2818 the same conclusion is reached for each data set. If the same conclusion is not reached or any 2819 exceptions are reported that were not reported in the original survey, further evaluations will be 2820 performed.

2821 5.8.3.2.5.9.3.2.

Duplicate and Split Samples 2822 A split sample is when the original sample aliquot is separated into two aliquots and analyzed as 2823 separate samples. A duplicate sample is a second complete sample taken at the same location and same 2824 time as the original. For the FSS of surface and subsurface soils, asphalt, and sediment, a split sample 2825 analysis will be performed on 5% of the soil samples taken in a survey unit with the locations selected 2826 at random. Duplicate samples will be acquired in accordance with the direction in the specific survey 2827 package or sample plan. In addition, approximately 5% of the total number of split samples taken will 2828 be sent for analysis by a qualified off-site laboratory or separate sample analysis by the on-site 2829 laboratory using a separate detector.

2830 The NRC Inspection Procedure No. 84750 Radioactive Waste Treatment, and Effluent and 2831 Environmental Monitoring (Reference 5-21201) will be used to determine the acceptability of split 2832 and duplicate sample analyses. The sample results will be compared to determine accuracy and 2833 precision. Agreement is ultimately determined when the same conclusion is reached for each compared 2834 result. If the split sample or duplicate sample results do not agree, then further evaluations will be 2835 performed.

2836 5.8.3.3.5.9.3.3.

Field Blanks and Spiked Samples 2837 Field blanks and spiked samples will not be performed on a routine basis. Field blanks and spiked 2838 samples will only be performed when directed by the Characterization/License Termination Manager.

2839 The acceptance criteria for field blank samples are that no plant derived radionuclides above 2840 background are detected. If the analysis of the field blank shows the presence of plant derived 2841 radionuclides, then further evaluations will be performed.

2842 Spiked sample results will be compared with the expected results to determine accuracy and precision 2843 in the same manner as duplicate or split samples. Agreement is ultimately determined that the same 2844 conclusion is reached for each compared result. If the spiked sample results do not agree with the 2845 expected results, further evaluations will be performed.

2846 5.8.3.4.5.9.3.4.

QC Investigations 2847 If QC replicate measurements or sample analyses fall outside of their acceptance criteria, a documented 2848 investigation will be performed in accordance with approved procedures; and if necessary, shall warrant 2849 a condition report in accordance with ZionSolutions procedure ZS-AD-08, Corrective Action 2850 Program (Reference 5-22221). The investigation will typically involve verification that the proper 2851 data sets were compared, the relevant instruments were operating properly and the survey/sample points 2852 were properly identified and located. Relevant personnel will be interviewed, as appropriate, to 2853

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-84 determine if proper instructions and procedures were followed and proper measurement and handling 2854 techniques were used including CoC, where applicable. When deemed appropriate, additional 2855 measurements will be taken. Following the investigation, a documented determination is made 2856 regarding the usability of the survey data and if the impact of the discrepancy adversely affects the 2857 decision on the radiological status of the survey unit.

2858 5.8.4.5.9.4.

Assessment and Oversight 2859 5.8.4.1.5.9.4.1.

Assessments 2860 Focused self-assessments of FRS FSS activities will be performed in accordance with applicable 2861 guidenceguidance. The findings will be tracked and trended.

2862 5.8.4.2.5.9.4.2.

Independent Review of Survey Results 2863 Randomly selected survey packages (approximately 5%) from survey units will be independently 2864 reviewed to ensure that the survey measurements have been taken and documented in accordance with 2865 approved procedures.

2866 5.8.4.3.5.9.4.3.

Corrective Action Process 2867 The corrective action process, already established as part of the site QA Program, will be applied to FSS 2868 and STS for the documentation, evaluation, and implementation of corrective actions. The process will 2869 be conducted in accordance with ZS-AD-08, which describes the methods used to identify potential 2870 conditions adverse to quality (CAQ), condition reporting, self-assessment resolution and corrective 2871 action issues related to FSS and STS. The CAQ evaluation effort is commensurate with the 2872 classification of the CAQ and could include root cause determination, extent of condition reviews, and 2873 preventive and remedial actions.

2874 5.8.4.4.5.9.4.4.

Corrective Action Process 2875 Reports of audits and trend data will be reported to management in accordance with the QAPP and 2876 approved procedures.

2877 5.8.5.5.9.5.

Data Validation 2878 Survey data will be reviewed prior to evaluation or analysis for completeness and for the presence of 2879 outliers. Comparisons to investigation levels will be made and measurements exceeding the 2880 investigation levels will be evaluated. Procedurally verified data will be subjected to the Sign test and 2881 unity rule as appropriate, the WRS test, or Unity as appropriate.

2882 5.8.6.5.9.6.

NRC and State Confirmatory Measurements 2883 The NRC may take confirmatory measurements to assist in making a determination in accordance with 2884 10 CFR 50.82(a)(11) that the FSS and STS, and associated documentation, demonstrate the site is 2885 suitable for release in accordance with the criteria for decommissioning in 10 CFR 20.1402.

2886 Confirmatory measurements may include collecting radiological measurements for the purpose of 2887 confirming and verifying the adequacy of the ZSRP FSS and STS measurements. Timely and frequent 2888

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-85 communications with the NRC will ensure it is afforded sufficient opportunity for these confirmatory 2889 measurements prior to implementing any irreversible decommissioning actions.

2890 5.9.5.10.

Final Status Survey Data Assessment 2891 The DQA approach being implemented at ZSRP is an evaluation method used during the assessment 2892 phase of FSS to ensure the validity of FSS results and demonstrate achievement of the survey plan 2893 objectives. In this context, STS is considered as a FSS. The level of effort expended during the DQA 2894 process will typically be consistent with the graded approach used during the DQO process. The DQA 2895 process will include a review of the DQOs and survey plan design, will include a review of preliminary 2896 data, will use appropriate statistical testing, will verify the assumptions of the statistical tests, and will 2897 draw conclusions from the data. The DQA includes:

2898

  • verification that the measurements were obtained using approved methods; 2899
  • verification that the quality requirements were met; 2900
  • verification that the appropriate corrections were made to any gross measurements and that the data 2901 is expressed in the correct reporting units; 2902
  • verification that the measurements required by the survey design, and any measurements required to 2903 support investigation(s) have been included; 2904
  • verification that the classification and associated survey unit design remain appropriate based on a 2905 preliminary review of the data; 2906
  • subjecting the measurement results to the appropriate statistical tests; 2907
  • determining if the residual radioactivity levels in the survey unit meet the applicable release 2908 criterion, and if any areas of elevated radioactivity exist.

2909 Once the FSS data are collected, the data for each survey unit will be assessed and evaluated to ensure 2910 that it is adequate to support the release of the survey unit. Simple assessment methods such as 2911 comparing the survey data mean result to the appropriate DCGLw will be performed first. The SOF will 2912 be calculated for soil data to ensure a value less than unity to demonstrate compliance with the TEDE 2913 criterion, as several radioisotopes are measured. The specific non-parametric statistical evaluations will 2914 then be applied to the final data set as necessary including the EMC (if applicable) and the verification 2915 of the initial data set assumptions. Once the assessment and evaluation is complete, any conclusions 2916 will be made as to whether the survey unit actually meets the site release criteria or whether additional 2917 actions will be required.

2918 In some cases, data evaluation will show that all of the measurements made in a given survey unit were 2919 below the applicable DCGLw. If so, demonstrating compliance with the release criterion is simple and 2920 requires little in the way of analysis. In other cases, residual radioactivity may exist where 2921 measurement results both above and below the DCGLw are observed. In these cases, statistical tests 2922 must be performed to determine whether the survey unit meets the release criterion. The statistical tests 2923 that may be required to make decisions regarding the residual radioactivity levels in a survey unit 2924 relative to the applicable DCGLw must be considered in the survey design to ensure that a sufficient 2925 number of measurements are collected.

2926

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-86 For ZSRP, the Sign Test is the most appropriate test for FSS. Characterization surveys indicate that Cs-2927 137 found in background due to global fallout constitutes a small fraction of the DCGLw.

2928 Consequently, the Sign Test will be applied to open land, basements surfaces (to include steel liner) 2929 embedded pipe, penetrations and buried piping when demonstrating compliance with the unrestricted 2930 release criteria without subtracting background.The statistical tests will include the Sign test, or the 2931 WRS test for instances when the measurement results are corrected for the contribution from 2932 background radioactivity. For Zion, the Sign Test is expected to be the most appropriate test for FRS.

2933 Characterization surveys indicate that Cs-137 found in background due to global fallout constitutes a 2934 small fraction of the DCGLw. Consequently, Zion intends to apply the Sign Test to open land survey 2935 units and buried piping when demonstrating compliance with the unrestricted release criteria without 2936 subtracting background. If a situation is encountered where continuing characterization surveys 2937 indicate that background is a significant fraction of the DCGLw for any plant-derived ROC, then the 2938 WRS Test may be used.

2939 Survey results will be converted to appropriate units of measure (e.g., dpm/100 cm2, pCi/g, pCi/m2) and 2940 compared to investigation levels to determine if the action levels for investigation have been exceeded.

2941 The mean values from FSS will include the results of judgmental samples based on an area-weighted 2942 average approach. Measurements exceeding investigation action levels will be investigated. If 2943 confirmed within a Class 1 survey unit, the location of elevated concentration may be evaluated using 2944 the EMC, or the location may be remediated and re-surveyed. If measurements exceeding investigation 2945 action levels are confirmed within a Class 2 or 3 survey unit, in most cases, the entire survey unit will 2946 be reclassified and a re-survey performed consistent with the change in classification.

2947 5.9.1.5.10.1. Review of DQOs and Survey Plan Design 2948 Prior to evaluating the data collected from a survey unit against the release criterion, the data are first 2949 confirmed to have been acquired in accordance with all applicable procedures and QA/QC 2950 requirements.

2951 The DQO outputs will be reviewed to ensure that they are still applicable. The data collection 2952 documentation will be reviewed for consistency with the DQOs, such as ensuring the appropriate 2953 number of measurements or samples were obtained at the correct locations and that they were analyzed 2954 with measurement systems with appropriate sensitivity. A checklist will be incorporated into the 2955 approved procedure for FSS data assessment and this checklist will be used in the review. Any 2956 discrepancies between the data quality or the data collection process and the applicable requirements 2957 will be resolved and documented prior to proceeding with data analysis. Data assessment will be 2958 performed by trained personnel using the approved procedure.

2959 5.9.2.5.10.2. Preliminary Data Review 2960 The first step in the data review process is to convert all of the survey results to the appropriate units.

2961 Basic statistical quantities are then calculated for the sample data set (e.g., mean, standard deviation, 2962 and median). An initial assessment of the sample and measurement results will be used to quickly 2963 determine whether the survey unit passes or fails the release criterion or whether one of the specified 2964 non-parametric statistical analyses must be performed.

2965 Individual measurements and sample concentrations will be compared to the DCGLw for evidence of 2966 small areas of elevated radioactivity or results that are statistical outliers relative to the rest of the 2967

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-87 measurements. For soils and buried pipemost FSS, interpreting the results from a survey is most 2968 straightforward when all measurements are higher or lower than the DCGLw. For structures, the 2969 preliminary data review will involve comparing the mean inventory times the Basement Dose Factors to 2970 the 25 mrem/yr dose criterion. In such cases, the decision that a survey unit meets or exceeds the 2971 release criterion requires little in terms of data analysis. However, formal statistical tests provide a 2972 valuable tool when a survey units measurements are neither clearly above nor entirely below the 2973 DCGLw or mean source inventory level.

2974 5.9.2.1.5.10.2.1.

Data Validation 2975 The initial step in the preliminary review of the FSS data is a validation of the data to ensure that the 2976 data is complete, fully documented and technically acceptable. At a minimum, data validation should 2977 include the following actions:

2978

  • Ensure that the instrumentation MDC for fixed or volumetric measurements was below the DCGLw 2979 or if not, it was below the DCGLEMC for Class 1, below the DCGLw for Class 2 and below 0.5 2980 DCGLw for Class 3 survey unitsdirect measurements and sample analyses was less than 10% of the 2981 DCGL, which is preferable. MDCs up to 50% of the DCGL are acceptable, 2982
  • Ensure that the instrument calibration was current and traceable to NIST standards, 2983
  • Ensure that the field instruments used for FSS were source checked with satisfactory results before 2984 and after use each day that data were collected, 2985
  • Ensure that the MDCs and assumptions used to develop them were appropriate for the instruments 2986 and techniques used to perform the survey, 2987
  • Ensure that the survey methods used to collect data were proper for the types of radiation involved 2988 and for the media being surveyed, 2989
  • Ensure that the sample was controlled from the point of sample collection to the point of obtaining 2990
results, 2991
  • Ensure that the data set is comprised of qualified measurement results collected in accordance with 2992 the survey design which accurately reflect the radiological status of the facility, and 2993
  • Ensure that the data have been properly recorded.

2994 If the data review criteria are not met, the discrepancy(s) will be evaluated and the decision to accept or 2995 reject the data will be documented in accordance with approved procedures. A condition report 2996 generated in accordance with ZS-AD-08 will be used to document and resolve discrepancies as 2997 applicable.

2998 5.9.2.2.5.10.2.2.

Graphical Data Review 2999 Graphical analyses of survey data that depict the spatial correlation of the measurements are especially 3000 useful for such assessments and will be used to the extent practical. At a minimum, a graphical review 3001 should consist of a posting plot and a frequency plot or histogram. Additional data review 3002 methodologies may be used and are detailed in section 8.2.2 of MARSSIM.

3003

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-88 5.9.2.2.1.5.10.2.2.1. Posting Plot 3004 Posting plots may be used to identify spatial patterns in the data. The posting plot consists of the survey 3005 unit map with the numerical data shown at the location from which it was obtained. Posting plots can 3006 reveal patches of elevated radioactivity or local areas in which the DCGL is exceeded. Posting plots 3007 can be generated for background reference areas to point out spatial trends that might adversely affect 3008 the use of the data. Incongruities in the background data may be the result of residual, undetected 3009 activity, or they may just reflect background variability.

3010 5.9.2.2.2.5.10.2.2.2. Frequency Plot 3011 Frequency plots may be used to examine the general shape of the data distribution. Frequency plots are 3012 basically bar charts showing data points within a given range of values. Frequency plots reveal such 3013 things as skewness and bimodality (having two peaks). Skewness may be the result of a few areas of 3014 elevated activity. Multiple peaks in the data may indicate the presence of isolated areas of residual 3015 radioactivity or background variability due to soil types or differing materials of construction.

3016 Variability may also indicate the need to more carefully match background reference areas to survey 3017 units or to subdivide the survey unit by material or soil type.

3018 5.9.3.5.10.3. Applying Statistical Test 3019 The statistical evaluations that will be performed will test the null hypothesis (Ho) that the residual 3020 radioactivity within the survey unit exceeds the DCGLw. There must be sufficient survey data at or 3021 below the DCGLw to statistically reject the null hypothesis and conclude the survey unit meets the site 3022 release criteria. These statistical analyses may be performed using a specially designed software 3023 package such as COMPASS or, as necessary, using hand calculations and/or electronic spreadsheets 3024 and/or databases.

3025 5.9.3.1.5.10.3.1.

Sum-of-Fractions 3026 The SOF or unity rule will be applied to FSS data in accordance with the guidance provided in 3027 section 2.7 of NUREG-1757. This will be accomplished by calculating a fraction of the DCGL for each 3028 sample or measurement by dividing the reported concentration by the DCGLw. If a sample has multiple 3029 ROC, then the fraction of the DCGL for each ROC will be summed to provide a SOF for the sample.

3030 If a surrogate DCGL was calculated as part of the survey design for the FSS, then the surrogate DCGL 3031 calculated will be used for the selected surrogate radionuclide. Unity rule equivalents will be calculated 3032 for each measurement result using the surrogate adjusted DCGL (typically using Cs-137) as shown in 3033 the following equation:

3034 Equation 5-1217 3035 SOF 1= ConcCs-137 DCGLCs-137s

+ ConcCo-60 DCGLCo-60

+ Concn DCGLn 3036 where:

3037 ConcCs-137

=

measured mean concentration for Cs-137, 3038 DCGLCs-137s =

Surrogate DCGLw for Cs-137, 3039 ConcCo-60

=

measured mean concentration for Co-60, 3040

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-89 DCGLCo-60 =

DCGLw for Co-60, 3041 Concn

=

measured mean concentration for radionuclide n, 3042 DCGLn

=

DCGLw for radionuclide n.

3043 The unity rule equivalent results will be used to demonstrate compliance assuming the DCGL is equal 3044 to one. If the application of the WRS or Sign test is necessary, these tests will be applied using the 3045 unity rule equivalent results and assuming that the DCGL is equal to one.

3046 5.9.3.2.

Wilcoxon Rank Sum Test 3047 The WRS Test is a non-parametric statistical evaluation typically used when the ROC is present in the 3048 background. In addition, this test is valid only when less than measurement results do not exceed 40 3049 percent of the data set. Note that the use of less than values will be avoided whenever practical. In 3050 order to apply the WRS Test, a reference background area must be established and reference 3051 measurements or samples collected. For the site, if the WRS Test is used, the test will be applied to the 3052 soil surveys using the guidance in section 8.4 of MARSSIM.

3053 In the event that the WRS Test fails, the survey unit will be re-evaluated to determine whether 3054 additional remediation will be required or the FSS re-designed to collect more data (i.e., a higher 3055 frequency of measurements and samples).

3056 5.9.3.3.5.10.3.2.

Sign Test 3057 The Sign Test is a non-parametric statistical evaluation typically used in situations when evaluating 3058 sample analyses where the ROC are not present in background, they are present at acceptably low 3059 fractions as compared to the DCGLw. The Sign Test will be applied using the guidance in section 8.3 of 3060 MARSSIM.

3061 In the event that the Sign Test fails, the survey unit will be re-evaluated to determine whether additional 3062 remediation will be required or the FSS re-designed to collect more data (i.e., a higher frequency of 3063 measurements and samples).

3064 5.9.4.5.10.4. Elevated Measurement Comparison Evaluation 3065 During FSS, areas of elevated activity (hot spots) may be detected and they must be evaluated both 3066 individually and in total to ensure compliance with the release criteria. The EMC is only applicable to 3067 Class 1 survey units when an elevated area is identified by surface scans and/or biased and systematic 3068 samples or measurements. The application of the DCGLEMC in basement surfaces is addressed in 3069 section 5.5.3.

3070 The investigation level for the EMC is the DCGLEMC, which is the DCGLw modified by an AF.

3071 Locations identified by surface scans or sample analyses which exceed the DCGLw are subject to 3072 additional surveys to determine compliance with the elevated measurement criteria. Based upon the 3073 size of the elevated measurement area, the corresponding AF will be determined from Tables 5-7 10 3074 and 5-8 11 using linear or exponential interpolation as necessary.

3075 Any identified elevated areas are each compared to the specific DCGLEMC value calculated for the size 3076 of the affected area. If the individual elevated areas pass, then they are combined and evaluated under 3077 the unity rule. This will be performed by determining the fraction of dose contributed by the average 3078

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-90 radioactivity across the survey unit and by adding the additional dose contribution from each individual 3079 elevated area following the guidance as provided in section 8.5.1 and section 8.5.2 of MARSSIM.

3080 The average activity of each identified elevated areas is determined as well as the average activity value 3081 for the survey unit. The survey unit average activity value is divided by the DCGLW, the survey unit 3082 average value is then subtracted from the average activity value for the elevated area and the result is 3083 divided by the appropriate DCGLEMC. The net average activity for each identified elevated area is 3084 evaluated against its applicable DCGLEMC. The fractions are summed and the result must be less than 3085 unity for the survey unit to pass. This is summarized in the equation as follows; 3086 Equation 5-1318 3087

+

1 1

+

2 2

+

<1 3088 where:

3089

=

the survey unit average activity; 3090 DCGLW

=

the survey unit DCGL concentration, 3091 n

=

the average activity value of hot spot n, and 3092 DCGLEMCn =

the DCGLEMC concentration of hot spot n.

3093 5.9.5.5.10.5. Data Conclusions 3094 The results of the statistical testing, including the application of the EMC, allow for one of two 3095 conclusions to be made. The first conclusion is that the survey unit meets the site release criterion 3096 through the rejection of the null hypothesis. The data provide statistically significant evidence that the 3097 level of residual radioactivity within the survey unit does not exceed the release criteria. The decision 3098 to release the survey unit will then be made with sufficient confidence and without any further analyses.

3099 The second conclusion that can be made is that the survey unit fails to meet the release criteria. The 3100 data may not be conclusive in showing that the residual radioactivity is less than the release criteria. As 3101 a result, the data will be analyzed further to determine the reason for failure. Potential reasons may 3102 include:

3103

  • The average residual radioactivity exceeds the DCGLW; 3104
  • The average residual radioactivity is less than the DCGLW; however, the survey unit fails the EMC 3105 test; 3106
  • The survey design or implementation was insufficient to demonstrate compliance for unrestricted 3107 release, (i.e., an adequate number of measurements was not performed); or, 3108
  • The test did not have sufficient power to reject the null hypothesis (i.e., the result is due to random 3109 statistical fluctuation).

3110 Power in this context refers to the probability that the null hypothesis is rejected when it is indeed 3111 false. The power of the statistical test is a function of the number of measurements made and the 3112 standard deviation of the measurement data. Quantitatively, the power is 1 -, where is the Type II 3113 error rate (the probability of accepting the null hypothesis when it is actually false). A retrospective 3114 power analysis can be used in the event that a survey unit is found not to meet the release criterion to 3115

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-91 determine if this is indeed due to excess residual radioactivity or if it is due to an inadequate sample 3116 size. A retrospective power analysis may be performed using the methods as described in section I.9 3117 and section I.10 of MARSSIM.

3118 If the retrospective power analysis indicates insufficient power, then an assessment will be performed to 3119 determine whether the observed median concentration and/or observed standard deviation are 3120 significantly different from the estimated values used during the DQO process. The assessment may 3121 identify and propose alternative actions to meet the objectives of the DQOs. These alternative actions 3122 may include failing the unit and starting the DQO process over, remediating some or all of the survey 3123 unit and starting the DQO process over and adjusting the LBGR to increase sample size. For example, 3124 the assessment determines that the median residual concentration in the survey unit exceeds the 3125 DCGLW or is higher than was estimated and planned for during the DQO process. A likely cause of 3126 action might be to fail the unit or remediate and resurvey using a new sample design. As another 3127 example, the assessment determines that additional samples are necessary to provide sufficient power.

3128 One course of action might be to determine the number of additional samples and collect them at 3129 random locations. Note, this method may increase the Type I error, therefore agreement with the 3130 regulator will be necessary prior to implementation. Another action would be to resample the survey 3131 unit with a new (and appropriate) number of samples and/or a new survey design.

3132 There may be cases where the decision was made during the DQO process by the planning team to 3133 accept lower power. For instance, during the DQO process the calculated relative shift was found to be 3134 less than one. The planning team adjusts the LBGR, evaluates the impact on power and accepts the 3135 lower power. In this case, the DQA process would require the planning team to compare the 3136 prospective power analysis with the retrospective power analysis and determine whether the lower 3137 power is still justified and the DQOs satisfied.

3138 5.10.5.11.

Final Radiation Survey Reporting 3139 Documentation of the FRS FSS will be contained in two types of reports and will be consistent with 3140 section 8.6 of MARSSIM. An FSS or STS Survey Unit Release Record will be prepared to provide a 3141 complete record of the as-left radiological status of an individual survey unit, relative to the specified 3142 release criteria. Survey Unit Release Records will be made available to the NRC for review as 3143 appendices to the appropriate FSS or STS Final Report. An FSS or STS Final Report, which is a 3144 written report that is provided to the NRC for its review, will be prepared to provide a summary of the 3145 survey results and the overall conclusions which demonstrate that the site, or portions of the site, meets 3146 the radiological criteria for unrestricted use, including ALARA.

3147 It is anticipated that the FSS or STS Final Report will be provided to the NRC in phases as remediation 3148 and FSS or STS are completed with related portions of the site. The phased approach for submittal is 3149 intended to provide NRC with detailed insight regarding the remediation and FSS/STS early in the 3150 process, to provide opportunities for improvement based on feedback, and to support a logical and 3151 efficient approach for technical review and independent verification.

3152 5.10.1.5.11.1. FSS and STS Unit Release Records 3153 An FSS or STS Unit Release Record will be prepared upon completion of the FSS or STS for a specific 3154 survey unit. Sufficient data and information will be provided in the release record to enable an 3155

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-92 independent re-creation and evaluation at some future time. The FSS or STS Unit Release Record will 3156 contain the following information:

3157

  • Survey unit description, including unit size, descriptive maps, plots or photographs and reference 3158 coordinates; 3159
  • Classification basis, including significant HSA and characterization data used to establish the final 3160 classification; 3161
  • DQOs stating the primary objective of the survey; 3162
  • Survey design describing the design process, including methods used to determine the number of 3163 samples or measurements required based on statistical design, the number of biased or judgmental 3164 samples or measurements selected and the basis, method of sample or measurement locating, and a 3165 table providing a synopsis of the survey design; 3166
  • Survey implementation describing survey methods and instrumentation used, accessibility 3167 restrictions to sample or measurement location, number of actual samples or measurements taken, 3168 documentation activities, QC requirements and scan coverage; 3169
  • Survey results including types of analyses performed, types of statistical tests performed, surrogate 3170 ratios, statement of pass or failure of the statistical test(s);

3171

  • QC results to include discussion of split samples and/or QC replicate measurements; 3172
  • Results of any investigations; 3173
  • Any remediation activities, both historic and resulting from the performance of the FSS or STS; 3174
  • Any changes from the FSS or STS survey design including field changes; 3175
  • DQA conclusions; 3176
  • Any anomalies encountered during performance of the survey or in the sample results; and, 3177
  • Conclusion as to whether or not the survey unit satisfied the release criteria and whether or not 3178 sufficient power was achieved.

3179 5.10.2.5.11.2. FSS and STS Final Reports 3180 The ultimate product of FRS FSS is an FSS or STS Final Report which will be, to the extent practical, a 3181 stand-alone document. To facilitate the data management process, as well as overall project 3182 management, FSS and STS Final Reports will usually incorporate multiple FSS or STS Unit Release 3183 Records. To minimize the incorporation of redundant historical assessment and other FRS FSS 3184 program information, and to facilitate potential partial site releases from the current license, FSS and 3185 STS Final Reports will be prepared and submitted in a phased approach. FSS and STS Final Reports 3186 will contain the following information:

3187

  • A brief overview discussion of the FRS FSS Program including descriptions regarding survey 3188 planning, survey design, survey implementation, survey data assessment, and QA and QC measures; 3189

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-93

  • A description of the site, the applicable survey area(s) and survey unit(s), a summary of the 3190 applicable HSA information, conditions at the time of survey, identification of potential 3191 contaminants, and radiological release criteria; 3192
  • A discussion regarding the DQOs, survey unit designation and classification, background 3193 determination, FSS or STS plans, survey design input values and method for determining sample 3194 size, instrumentation (detector efficiencies, detector sensitivities, instrument maintenance and 3195 control and instrument calibration), ISOCS Efficiency Calibration geometry, survey methodology, 3196 QC surveys, and a discussion of any deviations during the performance of the FSS or STS from 3197 what was described in this LTP; 3198
  • A description of the survey findings including data conversion, survey data verification and 3199 validation, evaluation of number of sample/measurement locations, a map or drawing showing the 3200 reference system and random start systematic sample locations, and comparison of findings with the 3201 appropriate DCGL or Action Level including statistical evaluations.

3202

  • Description of any judgmental and miscellaneous sample data collected in addition to those required 3203 for performing the statistical evaluation.

3204

  • Description of anomalous data, including any areas of elevated direct radiation detected during 3205 scanning that exceeded the investigation level or measurement locations in excess of DCGLW.

3206

  • If survey unit fails the statistical test, a description of any changes in initial survey unit assumptions 3207 relative to the extent of residual radioactivity, the investigation conducted to ascertain the reason for 3208 the failure and the impact that the failure has on the conclusion that the facility is ready for final 3209 radiological surveys, and a discussion of the impact of the failure on survey design and result for 3210 other survey units.

3211

  • Description of how ALARA practices were employed to achieve final activity levels.

3212 As appendices to the Final Report, the applicable FSS or STS Unit Release Record(s), all applicable 3213 implementing procedures and all applicable TSDs will be attached. If during a phased submittal, 3214 procedures and TSDs are submitted with the initial report, all subsequent submittals will only contain 3215 any revisions or additions to the applicable implementing procedures and/or TSDs.

3216 5.11.5.12.

Surveillance Following FSS and STS 3217 Isolation and control measures will be implemented in accordance with ZionSolutions site procedures as 3218 described in section 5.6.3. Isolation and control measures will remain in force throughout FSS and STS 3219 activities and until there is no risk of recontamination from decommissioning or the survey area has 3220 been released from the license. In the event that isolation and control measures established for a given 3221 survey unit are compromised, evaluations will be performed and documented to confirm that no 3222 radioactive material was introduced into the area that would affect the results of the FSS or STS.

3223 To provide additional assurance that open land survey units that have successfully undergone FSS 3224 remain unchanged until final site release, documented routine surveillances of the completed survey 3225 units will be performed. The surveillances will be performed in areas following FSS completion to 3226 monitor for indications of recontamination and verification of postings and access control measures.

3227 These routine surveillances will consist of; 3228

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-94

  • Review of access control entries since the performance of FSS or the last surveillance, 3229
  • A walk-down of the areas to check for proper postings, 3230
  • Check for materials introduced into the area or any disturbance that could change the FSS including 3231 the potential for contamination from adjacent decommissioning activities, 3232
  • If evidence is found of materials that may have been introduced into the survey unit or any 3233 disturbance that could change the FSS, thenPperformthen perform and document a biased scan of 3234 the survey areaunit, focusing on access and egress points and any areas of disturbance and/or 3235 concern.

3236 A routine surveillance will be performed in each completed FSS unit on a semi-annual basis. In 3237 addition, a surveillance may be performed at any time when an activity occurs that may have 3238 radiologically impacted the survey unit (e.g., transiting a radioactive material package though an FSS 3239 area, etc). These surveillances will be controlled and documented in accordance with the QAPP and 3240 approved procedures. If a routine surveillance identifies physical observations and/or radiological scan 3241 measurements that require further investigation, then FSS may be repeated in the affected survey unit.

3242 5.12.5.13.

References 3243 5-1 U.S. Nuclear Regulatory Commission NUREG-1575, Revision 1, Multi-Agency Radiation 3244 Survey and Site Investigation Manual (MARSSIM) - August 2000 3245 5-2 U.S. Nuclear Regulatory Commission NUREG-1505, Revision 1, A Nonparametric Statistical 3246 Methodology for the Design and Analysis of Final Status Decommissioning Surveys -

3247 June 1998 draft 3248 5-3 U.S. Nuclear Regulatory Commission NUREG-1507, Minimum Detectable Concentrations 3249 With Typical Radiation Survey Instruments for Various Contaminants and Field Conditions -

3250 June 1998 3251 5-4 U.S. Nuclear Regulatory Commission NUREG-1700, Revision 1, Standard Review Plan for 3252 Evaluating Nuclear Power Reactor License Termination Plans - April 2003 3253 5-5 U.S. Nuclear Regulatory Commission NUREG-1757, Volume 2, Revision 1, Consolidated 3254 Decommissioning Guidance - Characterization, Survey, and Determination of Radiological 3255 Criteria, Final Report - September 2003 3256 5-6 U.S. Nuclear Regulatory Commission Regulatory Guide 1.179, Standard Format and Content 3257 of License Termination Plans for Nuclear Power Reactors - January 1999 3258 5-7 Zion Nuclear Power Station, Units 1 and 2 Asset Sale Agreement - December 2007 3259 5-75-8 ZionSolutions Technical Support Document 14-016, Description of Embedded Piping, 3260 Penetrations and Buried Piping to Remain in Zion End State 3261 5-8 U.S. Nuclear Regulatory Commission NUREG-1575, Supplement 1, Multi-Agency Radiation 3262

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-95 Survey and Assessment of Materials and Equipment Manual (MARSAME) - December 2006 3263 5-9 ZionSolutions Technical Support Document 11-001, Potential Radionuclides of Concern 3264 during the Decommissioning of Zion Station 3265 5-10 ZionSolutions Technical Support Document 14-019, Radionuclides of Concern for Soil and 3266 Basement Fill Model Source Terms 3267 5-11 ZionSolutions Technical Support Document 14-011, Soil Area Factors 3268 5-12 ZionSolutions Technical Support Document 14-015, Buried Pipe Dose Modeling & DCGLs 3269 5-13 Zion Station Historical Site Assessment (HSA) - September 2006 3270 5-14 Sandia National Laboratories, NUREG/CR-5512, Volume 1, Final Report, Residual 3271 Radioactive Contamination from Decommissioning Parameter Analysis - October 1992 3272 5-15 ZionSolutions Technical Support Document 11-004, Ludlum Model 44-10 Detector 3273 Sensitivity 3274 5-16 ZionSolutions ZS-LT-01, Quality Assurance Project Plan (for Characterization and FSS) 3275 (QAPP) 3276 5-17 ZionSolutions Technical Support Document 10-002, Technical Basis for Radiological Limits 3277 for Structure/Building Open Air Demolition 3278 5-18 ZionSolutions Technical Support Document 14-013, Zion Auxiliary Building End State 3279 Estimated Concrete Volumes, Surface Areas, and Source Terms 3280 5-195-18 ZionSolutions ZS-QA-10, Quality Assurance Project Plan - Zion Station Restoration 3281 Project 3282 5-205-19 International Standard ISO 7503-1, Part 1, Evaluation of Surface Contamination, Beta-3283 Emitters (maximum beta energy greater than 0.15 MeV) and Alpha-Emitters - August 1998 3284 5-215-20 U.S. Nuclear Regulatory Commission Inspection Procedure No. 84750 Radioactive 3285 Waste Treatment, and Effluent and Environmental Monitoring - March 1994 3286 5-225-21 ZionSolutions ZS-AD-08, Corrective Action Program 3287

ZION STATION RESTORATION PROJECT LICENSE TERMINATION PLAN REVISION 1 5-96 Figure 5-1 Characterization/LTP/FSS Organization Chart 3288 Senior Vice President &

General Manager VP -

Environmental Safety & Health Characterization/

LTP Manager Radiological Engineer (LTP Lead)

Radiological Engineer (Characterization/Final Status Survey Lead)

Quality Assurance Manager Radiation Protection Instrumentation & Laboratory Organization Support

- Radiological Instrument Supervisor

-Radiochemist

-Count Room Technician

-Instrument Technician Radiological Engineer Characterization/

FSS Engineer/

Supervisors Characterization/

FSS Technicians 3289 3290