ML17208A116

From kanterella
Jump to navigation Jump to search
Tsd 14-016 Rev 0, Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State
ML17208A116
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 02/25/2017
From: Farr H
EnergySolutions, ZionSolutions
To:
Division of Decommissioning, Uranium Recovery and Waste Programs
Shared Package
ML17208A121 List: ... further results
References
TSD 14-016, Rev 0
Download: ML17208A116 (123)


Text

Page 1 of 123 ZionSolutions, LLC.

Technical Support Document TSD 14-016 Description of Embedded Piping, Penetrations, and Buried Pipe to Remain in Zion End State Revision 0 Originator: ___ _______________________ Date: __2/25/17__________

Harvey Farr Reviewer: ______________for DC per e-mail 02/23/17 Date:__ 2/25/17_________

David N. Carter Reviewer: ____________________________________ Date:__ 2/25/17________

Robert F. Yetter Approval: ____________________________________ Date: ___2/25/17________

Donald E. Williams

TSD 14-016 Revision 0 Page 2 of 123 Summary of Changes in this Revision:

  • Rev. 0 -Initial issuance.

TSD 14-016 Revision 0 Page 3 of 123 TABLE OF CONTENTS

1.

PURPOSE...................................................................................................................................... 7

2.

DEFINITIONS.............................................................................................................................. 7

3.

DISCUSSION................................................................................................................................ 7 3.1.

General Void Space Volume and Surface Area Method.....................................7 3.2.

Preliminary MARSSIM Classification.............................................................7

4.

CALCULATIONS......................................................................................................................... 8 4.1.

Containment Penetrations and Embedded Piping..............................................8 4.2.

Containment Incore Area Embedded Piping................................................... 11 4.3.

Main Steam and Tendon Tunnel Aerated Drain Piping.................................... 12 4.4.

Auxiliary Building Penetrations and Embedded Piping................................... 20 4.5.

Turbine Building Penetrations and Piping...................................................... 44 4.1.

Circulating Water Intake Piping.................................................................... 58 4.2.

Circulating Water Discharge Piping.............................................................. 62 4.3.

Crib House Penetrations and Embedded Piping.............................................. 67 4.4.

Waste Water Treatment Facility Penetrations and Buried Piping...................... 69 4.5.

Buried Piping Inventory............................................................................... 71 4.6.

Fuel Handling Building............................................................................... 71

5.

CONCLUSION............................................................................................................................ 72

6.

REFERENCES............................................................................................................................ 74

7.

ATTACHMENTS........................................................................................................................ 75 7.1.

Attachment A - Building Penetrations South................................................. 75 7.2.

Attachment B - Building Penetrations North.................................................. 75 7.3.

Attachment C - Building Penetrations East.................................................... 75 7.4.

Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains............ 75 7.5.

Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains............. 75 7.6.

Attachment F - End State Penetration and Piping Inventory............................ 75 7.7.

Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 75 7.8.

Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory.................................................................................................... 75 7.9.

Attachment I - Auxiliary Building Affiliated Penetrations and Piping.............. 75 7.10. Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 75 7.11. Attachment K - Waste Water Treatment Facility............................................ 75 7.12. Attachment L - Crib House Penetrations and Piping....................................... 75 7.13. Attachment M - Fuel Handling Building Affiliated Penetrations, Piping........... 75 7.14. Attachment N - Buried Pipe Penetrations and Piping Inventory........................ 75 7.15. Attachment O - Circulating Water Intake Penetrations and Piping................... 75 7.16. Attachment P - Circulating Water Discharge Piping Inventory........................ 75 LIST OF TABLES Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space.............................................................................................................................................. 10 Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes............... 10 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes............... 11 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume............... 12

TSD 14-016 Revision 0 Page 4 of 123 Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2......................................................... 12 Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3......................................................... 12 Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4......................................................... 13 Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5..................................................................... 13 Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7..................................................................... 13 Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe.............................................................. 13 Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump................................................ 14 Table 12 - Main Steam Tunnel Drain M9 Center Pipe........................................................................... 14 Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7...................... 14 Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths............................................. 15 Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10.................... 15 Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217................... 16 Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths............................................. 16 Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle.................................. 16 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space.............................................................................................................................................. 19 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space............................................................................................................................. 19 Table 21 - 24" Safety Injection Pipe Segments A36 and A51................................................................ 26 Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths................................................................................................................................................... 27 Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths................................................................................................................................................... 28 Table 24 -A40 Unit 1 4" Drain Line Segment Lengths.......................................................................... 29 Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths..................................................... 30 Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths................................................. 31 Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths.............................................................. 31 Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths..................................................... 32 Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths................................................... 33 Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2"................................................................. 33 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths.......................................... 34 Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths................................ 34 Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths................. 35 Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths..................................................... 35 Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths........................................... 36 Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths...................................................... 36 Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths

................................................................................................................................................................ 37 Table 38 - A58 OCT-061-2" Line Segment Lengths............................................................................. 38 Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths........................... 39 Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3". 41 Table 41 - Service Water Supply Header Pipe Lengths C26 & C29...................................................... 43 Table 42 - Summary of Auxiliary Building Affiliated Penetrations...................................................... 43 Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall.......................... 44 Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33.................. 48 Table 45 - Estimated Lengths of T95 and T102.................................................................................... 52 Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes............ 55

TSD 14-016 Revision 0 Page 5 of 123 Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping...................................................................................................................................................... 57 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes.................................................................................................................................................. 58 Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes.... 58 Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers....................................................................................................................... 60 Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128..................... 61 Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes.................................................................................................................................................. 62 Table 53 - 48 Inch Circulating Water Standpipe Lengths...................................................................... 64 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths.............................................. 67 Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths.............................................. 67 Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay....................... 67 Table 57 - Summary of Crib House Penetrations at Match Line AA.................................................... 68 Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space....................................................................................................................................................... 69 Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces..................................... 71 Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces. 72 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes...... 73 TABLE OF FIGURES Figure 1 - Overall Layout of Containment Penetrations.......................................................................... 8 Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4.......................................... 9 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping.................................................. 10 Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)....................................................................... 11 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210....................................................... 15 Figure 6 - Tendon Access Gallery Details (B-210)................................................................................ 17 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466............................................................. 18 Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23............................................. 20 Figure 9 - M-107 Sh2 Excerpt Top View............................................................................................... 21 Figure 10 - Side View Unit 1 Excerpt from B118.................................................................................. 22 Figure 11 - Side View Unit 2 Excerpt from B-120................................................................................ 22 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107......................................... 23 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106..................... 24 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions...................................................... 25 Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2................... 26 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall....................................................... 27 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2................................ 29 Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2........................................... 30 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines...................................... 31 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout........................................................ 32 Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply..................................... 34 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2............................................................ 37 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination.......................................................... 38 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path........................................................... 39 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout.............................................................. 40

TSD 14-016 Revision 0 Page 6 of 123 Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines................................... 40 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106................... 42 Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers.............................................................................................................................................. 42 Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106............................................. 44 Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104............................... 45 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103............................... 46 Figure 32 - Unit 2 North Diesel Oil Penetrations................................................................................... 47 Figure 33 - Unit 1 South Diesel Oil Penetrations................................................................................... 47 Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers..................... 48 Figure 35 - Turbine Building East Wall Penetrations - North................................................................ 50 Figure 36 - T95 and T102 Buried and Embedded Sections.................................................................... 51 Figure 37 - Turbine Building East Wall Penetrations - South................................................................ 52 Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building 53 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105................................................... 54 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103.......................... 56 Figure 41 - Circ Water Intake Supply to Condensers............................................................................. 59 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127..................... 61 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2.................................... 62 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel........................................ 63 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100.................. 64 Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100........................... 65 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return........................................................ 66 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2................................................................ 68 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005.. 70 Figure 50 - Top View Approximate Penetration Locations B-1024...................................................... 71

TSD 14-016 Revision 0 Page 7 of 123

1.

PURPOSE The purpose of this document is to provide an inventory of the embedded piping, buried piping, and penetrations that will remain in the end state structures (i.e., below 588 foot elevation) at the Zion Nuclear Power Station (ZNPS). The document provides a basis for the estimated lengths and diameters, and also estimates the surface areas and void spaces associated with them. The document also provides the current planned end state (e.g., pipe removed from penetration or pipe remains in penetration). Penetrations along with elevation and reference drawings for the Unit 1 and 2 Containments, Auxiliary Building, Spent Fuel Building, Turbine Building and Crib House, Tendon Tunnels, Main Steam Tunnels, and the Waste Water Treatment Facility WWTF are summarized in Attachments A thru E. A final list if all piping and penetrations with estimated lengths, surface areas, and void space is provided in Attachment F.

2.

DEFINITIONS Embedded Pipe - A pipe that is encased in concrete and that runs vertically through a concrete wall or horizontally through a concrete floor and is contained within a given building.

Buried Pipe - A pipe that runs through soil is defined as a buried pipe.

Pipe Penetration - A pipe (or remaining pipe sleeve, if the pipe is removed, or concrete, if the pipe and pipe sleeve is removed) that runs through a concrete wall and/or floor, between two buildings, and is open at the wall or floor surface of each building. A penetration could also be a pipe that runs through a concrete wall and/or floor and opens to a building on one end and the outside ground on the other end.

3.

DISCUSSION 3.1.

General Void Space Volume and Surface Area Method The use of the inside versus outside diameter varies depending on whether or not the piping is embedded and cannot be removed but will left in place and surveyed. If the piping is removed the outer diameter is used unless it is through a larger sleeve, in which case the inside diameter of the sleeve is used. The equation used for the inside surface area is Equation 1.

Equation 1 - Surface Area of Opening

= 2 Where r = the pipe radius used (inner or outer as described above) or the sleeve radius used.

h = pipe length in same units as r.

The equation for the void space volume is Equation 2.

Equation 2 - Void Space Volume of Opening

=

3.2.

Preliminary MARSSIM Classification A preliminary MARSSIM Classification was assigned to the piping and penetrations evaluated in this document. This classification was based upon knowledge of Pressurized Water Reactor systems and system contamination levels at Zion. Class 1 systems are those that have a high probability of a

TSD 14-016 Revision 0 Page 8 of 123 Derived Concentration Guideline Level concentration being exceeded. The systems are those that contained high activity water, such as Waste Discharge lines, Spent Fuel Pool, fill drain and clean-up lines, Residual Heat Removal lines, etc. Class 2 MARSSSIM lines are those that have a 50%

probability of exceeding a DCGL. These are generally secondary systems with the potential for cross contamination from primary system to secondary system leaks, such as Component Cooling, Main Steam, Feedwater, etc. Class 3 systems have a less than 50% chance of exceeding a DCGL. These are generally secondary systems with very low probabilities of significant cross contamination due to the volumes of the systems and potential decrees of cross contamination, such as Fire Protection, Primary Water, Demineralized Water, Station Air, Instrument Air, etc.

4.

CALCULATIONS 4.1.

Containment Penetrations and Embedded Piping As noted in TSD 13-005 (1) and TSD 13-006 (2) the current plan is to remove all concrete inside the liners of the containment except for the incore sump area and access tunnel. This will minimize the amount of embedded piping remaining in the end state such that penetrations will make up the bulk of the surface area.

Unit 1 and Unit 2 containment penetrations are provided in drawings Unit 1 M-281, M-282 and Unit 2 M-661, M-662. As seen in Attachments A and B, the penetrations are located in three areas in the containment walls, the east and west Main Steam Tunnels and the Unit 1 north and Unit 2 south penetrations into the Auxiliary Building pipe chases as seen in Figure 1. Current plans are to remove piping from these penetrations leaving only the sleeves.

Figure 1 - Overall Layout of Containment Penetrations The penetrations and through wall piping are identical in both Unit 1 and Unit 2. The penetrations and the length and diameters of the penetrations with and without the piping (i.e., Open Sleeve) are provided in Attachment F and G.

There are also penetrations where the pipe will remain in the penetration (Pipe in Sleeve). As seen in Figure 1, each containment also has a penetration for the fuel transfer tube connecting the lower

TSD 14-016 Revision 0 Page 9 of 123 cavity to the Fuel Handling Building Transfer Canal. Current plans are to leave the piping in place for these penetrations. The ends in the Containment up ender pit have blank flanges welded on as part of the cavity isolation preparations for internal segmentation. Since the end state requires all metals other than those embedded in concrete to me removed (3), it is anticipated that the pipes will be cut flush with the walls and open in the end state.

The length of the transfer tube piping in each unit is shown as 8 2.5 (e.g., 98.5 inches) in drawing B-213 Detail 4. With 24 inch OD and a 0.688 inch wall thickness the pipe ID is 22.624 inches. The void space volume is 39,597 cubic inches or 22.92 cubic feet (0.65 m3). The surface area is 48.62 ft2 or 4.52 m2.

Figure 2 -Penetration P-49 Fuel Transfer Tube Length from B-213 Detail 4 As seen in Figure 3, there are also three Recirculating Sump Suction lines and two Cavity Flood Sump Suction lines that connect to the Auxiliary Building. The pipes are planned to remain in their sleeves. All five pipes are 20 inch pipes with 24 inch sleeves embedded in the concrete below the liner at the 561.25 foot elevation. One Recirculation Sump line is a spare that is capped at the Auxiliary Building penetration. The estimated lengths are approximately 50 feet as seen in Figure 3. The wall thickness of the 20 inch pipe is 0.594 inches making the inside diameter 18.812 inches. Although each pipe varies slightly in length the interior surface area is approximately 252 ft2 (23.41 m2) and 98.7 ft3 (2.80 m3).

TSD 14-016 Revision 0 Page 10 of 123 Figure 3 - Unit 1 Recirculation Sump and Cavity Flood Sump Piping Each Unit 1 Cavity Flood Sump and Recirculation Sump pipes estimated length, surface area, and void space volume is provided in Table 1. The corresponding Unit 2 penetrations in Attachment F are P323, P324, P235, P236, and P237. The horizontal runs under the Containment 565 liner floor level are at the 5613 elevation making the top of the 24 inch diameter pipes at the 5623 elevation which is 29 below the end state liner floor level.

Table 1 - Unit 1 Recirculating Sump and Cavity Flood Sump Estimated Lengths, Surface Area and Void Space Pen No.

Description Pipe OD inches Wall Thkns Pipe ID inches Length Feet Interior Surface Area ft2 Void Space Volume ft3 Int SA m2 Void Space m3 P123 Recirculating Sump Suction 20 0.594 18.812 52.00 256.10 100.37 23.79 2.84 P124 Recirculating Sump Suction 20 0.594 18.812 52.83 260.20 101.98 24.17 2.89 P035 Recirculating Sump Suction 20 0.594 18.812 51.17 251.99 98.76 23.41 2.80 P036 Cavity Flood Sump Suction 20 0.594 18.812 50.75 249.94 97.96 23.22 2.77 P037 Cavity Flood Sump Suction 20 0.594 18.812 50.83 250.35 98.12 23.26 2.78 All of the other penetrations below the 588 elevation are assumed to have piping cut on either side of the penetration such that the length corresponds to the wall thickness and void space volume and interior surface areas correspond to the diameter as listed in Attachment F. The total estimated pipe lengths, surface areas and void space volumes in meters are provide in Table 2. The inventory associated with the Unit 1 and Unit 2 Containments are provided in Attachment G.

Table 2 - Summary of Unit 1 Containment End State Lengths, Surface Areas and Volumes Unit 1 Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 169.20 242.36 32.48 Open Sleeve 88.19 119.99 17.75 Pipe in Sleeve 81.01 122.37 14.73

TSD 14-016 Revision 0 Page 11 of 123 Grand Total 169.20 242.36 32.48 Table 3 - Summary of Unit 2 Containment End State Lengths, Surface Areas and Volumes Unit 2 Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 169.20 242.36 32.48 Open Sleeve 88.19 119.99 17.75 Pipe in Sleeve 81.01 122.37 14.73 Grand Total 169.20 242.36 32.48 4.2.

Containment Incore Area Embedded Piping There is also a 1 1/2 pipe embedded in the concrete of the Incore Access Tunnel P125 for Unit 1 and P325 for Unit 2 on Attachment F. The incore area extends below the containment slab and consists of a cylindrical area directly under the reactor vessel biological shield and a sloped tunnel. The incore area walls are 1 foot 11.5 inches thick (23.5 inches) with a 2 foot 6 inches under vessel area floor. There is also an access tunnel with 15 inch thick walls, floor and roof. The sump is shown on drawing B-234 as being 2x 2x 2 at about 1 from the from the bend line. The pipe enters the wall about a floor above the sump making the opposite of the triangle 17+9-36 or 226 as seen in Figure 4. The base is 433 - 309 or 126 making the hypotenuse length 25.74 assuming the pipe enters the wall for about a foot before sloping up results in an estimated length of 26.74.

Figure 4 - Incore Instrument Tunnel Sump Pipe (B-234)

The estimated length, surface area, and void space volume in meters is provided in Table 4. The inventory of the incore pies is provided at the end of Attachment G.

TSD 14-016 Revision 0 Page 12 of 123 Table 4 - Unit 1 Incore Sump Pipe Estimate Length, Surface Area and Void Space Volume Row Labels Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld Pen 8.15 1.05 0.01 Embedded Pipe 8.15 1.05 0.01 Grand Total 8.15 1.05 0.01 4.3.

Main Steam and Tendon Tunnel Aerated Drain Piping The tendon access tunnel galleries also contains a sump that has trace levels of contamination in sump water and sludge samples as well as trace levels of removable contamination. The Main Steam Tunnel floor drains also drain to this sump. There are 4 Aerated drains embedded in the tendon gallery access tunnel and Main Steam Tunnel floors. The Tendon Tunnel runs under the periphery of the Containment as shown in Figure 5 and has a floor elevation of 565-9-76 or 5486.As seen in Attachment D and Attachment E excerpted from drawings B-466, B-477, B-484, and B-487 the Main Steam Tunnel and Tendon Tunnel aerated drains are connected and drain to a common sump in the tendon tunnel. The Unit 1 drawings are shown on B-466 and B-467. The Unit 2 pipes are shown on B-481 and B-487. All of the pipes have a 4.5 inch outer diameter and 4.026 inch inner diameter. The penetrations are comprised of floor drains and clean out ports in the Mains Steam Tunnel that connect to a common header pipe. Attachment D shows M1 is a drain at 5696 1/2 to a bend beneath the floor. As seen on B-484 M1 drops to the 569 which is 0.54 feet. The pipe then makes a 45 degree run to the main drain line. As seen on B-466 the clean out port is 84 -2 thick wall or 64 from the wall. The 45 degree section is thus the hypotenuse of a 64 45 degree triangle or 8.96 feet. At Cleanout port M2 the pipe makes a 45 degree bend from the 569 to the 5687 or a 5 x 5 45 degree triangle which is 0.59 feet. The length of the run at 569 elevation between the 45 degree section is 48-64-5-6 from the wall or 353. As seen in Table 5. The Unit 2 drain M201 has slightly different lengths due to different elevations.

Table 5 - Main Steam Tunnel Drain Pipe Length from M1 to M2 Pipe Section M1 M201 Vertical 0.54 0.69 45 Degree Bend 8.96 8.96 45 Degree at Cleanout 0.59 0.62 Section between 45s 35.25 35.23 Total Length 45.34 45.49 Penetration M2 is a 4 cleanout port that has a vertical section from the 56911 floor of the tunnel to the 5673 or 28 where it runs under the floor in a concrete encasement as shown on drawing B-466. It then run 38 from M2 to M3 resulting in a distance of 408 as seen in Table 6. The Unit 2 drain M202 has slightly different lengths due to different elevations.

Table 6 - Main Steam Tunnel Drain Pipe Length from M2 to M3 Pipe Section M2 M202 Vertical 2.67 1.50 Section to M3, M203 38.00 38.00 Total Length 40.67 39.50 The M3 vertical is the same as M1. There is a 45 degree bend from 56811 to 5673 or 18 at M3. This creates a 2.36 length. The length from the drain to the 45 degree angle is 6-18 or 44. The distance from

TSD 14-016 Revision 0 Page 13 of 123 M3 to M4 at the 5673 elevation is 75-19+30 or 86 resulting in a total length of 93.23 feet as seen in Table 7. The Unit 2 drain M203 has slightly different lengths due to different elevations.

Table 7 - Main Steam Tunnel Drain Pipe Length from M3 to M4 Pipe Section M3 M203 Vertical 0.54 0.67 Drain to Section to 45 4.33 5.54 45 Degree Bend 2.36 0.65 Section to M4 86 86 Total Length 93.23 92.86 The vertical at M4 is the same as M1 and M3 at 6 1/2 or 0.54 feet. There is a 45 degree bend from the 56810 to the 5673 elevation or 17. The hypotenuse of the 17 45 degree triangle is 2.24 feet. The distance to the 45 degree bend is 6-17 or 45 which is 4.42 feet. There is a 45 degree bend from 5673 to 5662 or 11 near cleanout M5. There is a 45 degree bend at M5 from 5673 to the 5662 elevation or 11 which equals a 1.53 foot hypotenuse. The distance of the run at the 5673 from M4 to M5 is 92-30+26-11-10 for 76.92 resulting in 84.11 feet overall length from M4 to M5 as seen in Table 8. The Unit 2 drain M204 has slightly different lengths due to different elevations.

Table 8 - Main Steam Tunnel Drain Pipe from M4 to M5 Pipe Section M4 M204 Vertical 0.54 0.71 Section drain to 45 4.42 5.54 45 Degree Bend 2.24 0.65 Section to 45 degree at M5 76.92 75.96 45 bend at M5 1.53 2.89 Total Length 84.11 82.86 M5 is a clean out at G34 that has a vertical section from 56911 to 5662 or 39. The length of the 5662 pipe from M5 to M7 can be interpolated at 306 feet based on the 24 dimension between columns 33 and 34 on B-466. This provides and overall length from M5 to M7 of 343 feet as seen in Table 9. The Unit 2 drain M205 has slightly different lengths due to different elevations.

Table 9 - Main Steam Tunnel Drain Pipe from M5 to M7 Pipe Section M5 M205 Vertical 3.75 3.54 Section to M7 30.50 30.50 Total Length 34.25 34.04 M6 has a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5662 elevation for a 210 base resulting in a 4.01 hypotenuse. The distance from the drain to the wall is 10 feet leaving a 72 foot section from the drain to the 45 degree bend. This results in a 11.72 foot overall length as seen in Table 10. The Unit 2 drain M206 has slightly different lengths due to different elevations.

Table 10 - Main Steam Tunnel Drain Pipe M6 to Center Pipe Pipe Section M6 M206 Vertical 0.54 0.67 Section drain to 45 7.17 6.80

TSD 14-016 Revision 0 Page 14 of 123 45 Degree Bend 4.01 4.48 Total Length 11.72 11.95 M7 is a clean out with a vertical from the 56911 1/2 floor to 5661 or 310 1/2. The clean out connects to a main pipe segment that goes to the Tendon Tunnel Sump. Drawing B-481 is more legible showing the cleanout to the bend is 26-13+58 or 188 for Unit 2. B-481 shows the length of the bend to the vertical to be 22 7 1/2 or 22.625 feet. The vertical drop from 5658 to the Tendon Tunnel Sump at 5436 is 222 equaling a total length from M-7 to the sumo of 674 as seen in Table 11. The Unit 2 drain M207 has slightly different lengths due to different elevations.

Table 11 - Main Stream Tunnel Cleanout M7 to Tendon Tunnel Sump Pipe Section M7 to M8 M207 to M208 Vertical 3.88 3.85 Section to bend 18.67 18.67 Bend to Vertical at M8 22.625 22.625 Vertical M8 to Sump 22.17 21.67 Total Length 67.33 66.81 M9 is similar to the other drains with a vertical drop of 6.5 inches to the 569 elevation. It has a 45 degree bend to the 5687 elevation for 5 base resulting in a hypotenuse or a 5 x 5 45 degree triangle which is 0.59 feet. As seen on B-482 for the Unit 2 equivalent section the distance from M9 to the main pipe from M-10 to M-7 is 26 feet from match line J to L minus 49 from L to the wall interior and minus 13 from J to cleanout M-10. Thus, the length from the drain to the 45 degree bend is 26-49-13-5 or 710. As seen in Table 12, the total length is 8.96 feet. The Unit 2 drain M209 has slightly different lengths due to different elevations. The Unit 2 drain M209 has slightly different lengths due to different elevations.

Table 12 - Main Steam Tunnel Drain M9 Center Pipe Pipe Section M9 M209 Vertical 0.54 0.67 Section drain to 45 7.83 8.18 45 Degree Bend 0.59 0.10 Total Length 8.96 8.95 Cleanout port at M10 has a vertical from 56911 1/2 to 5689 1/2 or 1.17 feet. The equivalent section on B-481 shows a length of 193+226 or 419 from M10 to M7. The line drops 2.5 inches over this length but this does not add significantly to the length. The pipe the has a vertical drop from 5687 to 5661 or 26 to join the line from M7 to M8. This results in a total length from M10 to M7 of 45.42 feet. The Unit 2 drain M210 has slightly different lengths due to different elevations. The Unit 2 drain M210 has slightly different lengths due to different elevations.

Table 13 - Main Steam Tunnel Drain Pipe Length from Cleanout M10 to Cleanout M7 Pipe Section M10 to M7 M210 to M207 Vertical 1.17 1.16 Section to bend 41.75 41.81 Bend to Vertical at M7 to 566'1" 2.5 0.5 Total Length 45.42 43.47 M11 is similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M11 to center pipe can be interpolated at 165 feet based on the 24 dimension between columns 33 and 34

TSD 14-016 Revision 0 Page 15 of 123 on B-466. The length from the drain to the pipe is 6.96 feet as seen in Table 14. The Unit 2 drain M211 has slightly different lengths due to different elevations.

Table 14 - Main Steam Tunnel Drain M11 to Center Drain Pipe Lengths Pipe Section M11 M211 Vertical 0.54 0.60 Section drain to main pipe 16.42 16.42 Total Length 16.96 17.02 M12 is also a drain similar to the other drains with a 6 1/2 vertical to the 569 elevation. The length of the 569 pipe from M12 to center pipe is 21-14-165 or 33. The length to M10 from M12 is shown on the Unit 2 equivalent section of B-481 at 14+13 or 27. The total length is 20.79 feet as seen in Table 15. The Unit 2 drain M211 has slightly different lengths due to different elevations.

Table 15 - Main Steam Tunnel Drain Pipe Length from Cleanout M12 to Cleanout M10 Pipe Section M12 M12 Vertical 0.54 0.60 Section drain to main pipe 3.25 3.25 M12 to M10 27.00 27.00 Total Length 30.79 30.85 Figure 5 - Tendon Tunnel Access Gallery Side View from B-210 As seen in Figure 5, the Tendon Tunnel floor is at 5486 elevation. The walls and floors are 2 thick making the interior floor width 46. There are drains from the Tendon Tunnel Buttress Pits that connect drain header in the Tendon Tunnel. The Buttress Pits are divided in to two sections by a wall in the center. A drainage system consisting of a through wall drain that allows accumulated water in one chamber to drain into the adjacent chamber and then through a floor drain down to the tendon tunnel floor drain header connected to the tendon tunnel east sump. As seen in Figure 7, there are 5 Unit 1 drains M13 thru M17 and 5 Unit 2 M213 thru M217 from the Tendon Buttress Pits at the 564 11 1/2 that drop 13 1/2 to the 5638 where they run horizontally about 36 into the center of the 2 thick wall. The lines then run vertically to the 5479 which 9 below the Tendon Tunnel Floor slab. They then run horizontally on a 45 degree angle to join the drain

TSD 14-016 Revision 0 Page 16 of 123 pipes at the center of the tunnel. The tunnel is 46 wide making it 23 from the wall interior to the pipe.

The wall is 2 feet thick making the length to wall 1 foot making the base of the 45 degree pipe 33 which results in a total length of 4.6. This is a total length of 30.3 feet for each of the 5 pipes for a total of 151.52 feet per Unit as seen in Table 16.

Table 16 - Tendon Tunnel Access Drains Unit 1 M13 to M17 and Unit 2 M213 to M217 Pipe Section M13 - M17 M213 - M217 Vertical to Horizontal 1.29 1.29 Horizontal into Tendon Tunnel Wall 3.5 3.5 Vertical to Tunnel 20.92 20.92 Horizontal to Center Pipe 4.60 4.60 Total Individual Length 30.30 30.30 Total M13 - M17 Length 151.52 151.52 As seen in Figure 7, the Tendon Tunnel drains are embedded approximately 7 inches in the floor at the 54611 elevation. The drains M18 through M23 and M18 through M223 have a vertical section from 548 6 1/2to 54711 or 7 1/2. The total length of these vertical section in Unit 1 and Unit 2 is 39.

Table 17 - Unit 1 and Unit Tendon Tunnel Floor Drain Vertical Lengths Unit 1 Unit 2 Pen Length ft Pen Length ft M018 0.625 M218 0.625 M019 0.625 M219 0.625 M020 0.625 M220 0.625 M021 0.625 M221 0.625 M022 0.625 M222 0.625 M023 0.625 M223 0.625 Total 3.75 3.75 Drawing B-210 shows that the tunnels are 46 wide with 2 thick walls. B-481 shows that M18 is at the 368 degree mark and M23 is at the 68 degree mark. B-481 shows M223 is at the 68 degree mark and M218 is at 368 degrees. As seen in Table 18, the pipe is 83% of a circle.

Table 18 - Unit 1 and Unit 2 Tendon Tunnel Center Drain Percentage of Circle Unit 1 Unit 2 Start Degree End Degree Total Degrees Start Degree End Degree Total Degrees 68 0

68 68 0

68 360 368

-8 360 368

-8 Total 60 60 Pipe Percent Circle 83%

83%

As seen in Figure 6, it is 666 to the interior wall, with the pipe in the center that would add 23 making the pipe radius 689. This is also shown on drawing B-466 and B-481 as seen in Figure 7.

TSD 14-016 Revision 0 Page 17 of 123 Figure 6 - Tendon Access Gallery Details (B-210)

TSD 14-016 Revision 0 Page 18 of 123 Figure 7 - Unit 1 Tendon Tunnel Drain Pipe Overhead B-466 M24 and M244 are the circular portion of the embedded pipe. The 689 radius multiplied by 2 Pi and 0.83 for the percentage of the circle results in a 359.97 length. The pipe from M25 to the sump is 23 to the wall then 76 to the sump or 99.

A summary of the Unit 1 and Unit 2 Main Steam drains estimated lengths, surface areas and void space volumes in meters are provide in Table 19. Table 20 has the summary for the Buttress Pit and Tendon Tunnel drains. The list of penetrations and pipes is provided in Attachment H.

TSD 14-016 Revision 0 Page 19 of 123 Table 19 -Unit 1 and 2 Main Steam Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Category and End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 U1 Aerated Drain 145.93 46.88 1.20 U1 Bld Pen 145.93 46.88 1.20 Embedded Pipe 145.93 46.88 1.20 U2 Aerated Drain 144.41 46.39 1.19 U2 Bld Pen 144.41 46.39 1.19 Embedded Pipe 144.41 46.39 1.19 Grand Total 290.34 93.28 2.38 Table 20 - Unit 1 and 2 Buttress Pit and Tendon Tunnel Aerated Drains Estimated Lengths, Surface Areas and Void Space Category and End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 U1 Bld Pen 160.02 51.41 1.31 Embedded Pipe 160.02 51.41 1.31 U2 Bld Pen 160.02 51.41 1.31 Embedded Pipe 160.02 51.41 1.31 Grand Total 320.04 102.82 2.63

TSD 14-016 Revision 0 Page 20 of 123 4.4.

Auxiliary Building Penetrations and Embedded Piping Auxiliary Building penetrations are provided in drawings M-281, M-282 for Unit 1 and M-661, M-662 for Unit 2. The penetrations to the Spent Fuel Building are located at R17 and R23 as seen in Attachments A and B. Drawing M-107 Sheet 1 Section A-A and B-B show the end view of the penetrations in the Auxiliary Building as seen in Figure 8. Note that Unit 1 penetration A29 is unlabeled on M-107 Sheet 1. There is also an unlabeled penetration on M-107 Sheet 2 next to the A43 penetration of OFP-016-4 on M-107 Sheet 2 at Column 22 between match line X and U. However, this line is labeled on the drawing as 1SF-017-2 next to the OFP-016-4 at column 24 match line S.

Figure 8 - End View of Auxiliary Building Penetrations at R17 and R23.

TSD 14-016 Revision 0 Page 21 of 123 M-107 Sheet 2 shows most of the pipes paralleling the Spent Fuel Building foundations then rising vertically to above the 583 elevation after passing under the Fuel Transfer Canal. The exceptions being those pipes with boxes around them in Figure 8. These are a 2 inch diameter oil line A42 ODO-100-2 that remains near the 573 elevation and a 4 inch vent line A40 1AD-046-4 that only rises to the 579 elevation. These lines routes are traced in red in Figure 9. The Unit 1 and 2 24 diameter Safety Injection lines A36 and A51 also do not rise above the 573 elevation.

Figure 9 - M-107 Sh2 Excerpt Top View Enlarged Plan A and Plan B of M-107 Sheet 1 show the top view and piping lengths as the parallel the Containments and pass under the Spent Fuel Transfer Canal as seen in Figure 12. B-118 shows the side view of the Unit 1 piping relative to the foundation and clearly indicates as seen in the red circled notations noted in excerpt provided as Figure 10. The Unit 2 side view from B-120 has similar notations indicating the piping is encased in concrete as seen in Figure 11.

TSD 14-016 Revision 0 Page 22 of 123 Figure 10 - Side View Unit 1 Excerpt from B118 Figure 11 - Side View Unit 2 Excerpt from B-120

TSD 14-016 Revision 0 Page 23 of 123 Figure 12 - Auxiliary Building Piping Penetrations at R17 and R23 M-107 Drawing M-106 Sections K-K and K1-K1 show the side view of the piping passing through the walls of the Auxiliary Building, Under the Spent Fuel Transfer Canal and out through the Spent Fuel Building Walls as seen in Figure 13.

TSD 14-016 Revision 0 Page 24 of 123 Figure 13 - Side View of Piping at Penetration Auxiliary Building R17 and R23 M-106 As seen in Figure 8, Figure 9, Figure 10, and Figure 11 both Unit 1 and Unit 2 penetrations to the Spent Fuel Building have a 24 inch Safety Injection line 1SI-012-24 and 2SI-012-24 A36 and A51 that run from match line R to match line X. As seen in Figure 9 the lines were installed for a future Safety Injection tank that was never installed. Consequently, the lines are capped on both ends and were never used.

TSD 14-016 Revision 0 Page 25 of 123 Figure 14 - Summary of 24 Inch Safety Injection Line Dimensions As seen in Figure 14, the distance to the bend is 6 for the cap plus 39 and 159 as seen on M-107 Sheet 2 which is 20 feet. M-105 SH2 also shows the 45 degree bends is 310 the hypotenuse of which is 5.421 feet.

As seen in Figure 13, the centerline elevation at R is 568 plus 2 or 570. This makes the remaining distance to match line S 25-159-310 or 55. There is also an elevation change at the bend from 570 inches to

TSD 14-016 Revision 0 Page 26 of 123 573 feet increasing the length of the bend by the square root of 5.421^2 + 3^2 to a length of 6.2 feet. The distance from match line S to the end cap past X is 25+126 plus 1 to the end cap or 386 for a total length of 70.11 feet.

Table 21 - 24" Safety Injection Pipe Segments A36 and A51 Section Length feet End Cap at R 0.5 Length to elbow 19.5 Bend 6.20 Remaining to S 5.42 Remaining to End Cap 38.50 Total 70.11 As seen on Figure 8, each unit also has two 10 diameter component cooling lines A49 1CC-078-10, A50 1CC-080-10, A59 2CC-078-10, A60 2CC-080-10. They are at the 5707 at match line R. As seen in Figure 13, the pipes run horizontally from R to where they make a vertical rise to the 584 elevation. The length is 1+29+133+9+9 or 186. The pipes then rise vertically from 5707 to the 584 elevation or 135. For Unit 1 the pipes then run parallel to the SFB past match line X where they pass through the wall.

Figure 15 - Unit 1 and 2 10 Inch Component Cooling Lines Layout Excerpt M-107 SH2 The distance from vertical to match line S is25-149 or 103, the then proceeds 25 to X. Past X they turn North through the wall at A49 64 for 417 length and A50 710 for a 431 length.

TSD 14-016 Revision 0 Page 27 of 123 Figure 16 - Unit 1 Penetrations through Spent Fuel Building Wall As seen in Figure 8, A49 is 39+110 from Column 23 or 57 and A50 is an additional 14 from column 23 or 611. It is 26 from column 23 to column 21 and 176 to column 20. The Unit 1 penetrations through the 592 floor are 16 beyond that making the total from column 23 45 feet. A 4 foot long vertical section will remain from the 584 to the 588 elevation. The calculated pipe segment lengths and the overall lengths are summarized in Table 22.

Table 22 - Unit 1 10" Component Cooling Line A49 1CC-078-10" and A50 1CC-080-10" Segment Lengths Section A49 Unit 1 Length feet A50 Unit 1 Length feet Length R to Vertical to 584' 18.5 18.5 Length of Vertical 570'7" to 584' 13.42 13.42 Length from Vertical to SFB Wall Penetrations 41.58 43.08 Distance North to Col 23 5.58 6.92 Distance Col 23 to Vertical 45.00 45.00 Vertical Toward Slab 4

4 Total 128.08 130.92

TSD 14-016 Revision 0 Page 28 of 123 The Unit 2 10 Component Cooling lines A59 2CC-078-10 and A60 2CC-080-10 paths are also shown in Figure 15. The distance to the 584 vertical and to vertical lengths are the same as Unit 1 186 and 135.

The distance to S is 25-14-9 or 113. The distance to from X to the bend of A59 2CC-078-10 is noted as 3+39 or 69. There is an additional 6 feet from the notation of 8 pieces at 8 inches. The distance from S to the bend is the 25 from S to X minus 129 or 123. The total length of A59 2CC-078-10 from the vertical to 584 elevation is 236. The length of A60 2CC-080-10 is 26 closer to S or 21. For the southward segment between S & X as seen in Figure 15, the distance from column 17 is the distance from column 19 to 17 26-149 or 113 inches. As seen in Figure 8, the distance from column 17 to A59 2CC-078-10 is 39+110 or 57. A 60 2CC-080-10 is an additional 14 further or 611. The length of A59 to the bend north is 113+57 or 1610. The length of A60 is 113+611 or 182. The segment west past match line X for A59 2CC-078-10 is 26+3+39 to X with an additional 64 past X or 157. The distance west for A60 is 3+39+64+16 or 147. The distance south again to the vertical from 584 to the floor penetrations on 593 is 149+2 for both pipes as seen on Figure 15. A 4 long part of the vertical from 584 to 588 elevation will also remain. The lengths of each segment and totals lengths are provided in Table 23.

Table 23 - Unit 2 10" Component Cooling Line A59 2CC-078-10" and A60 2CC-080-10" Segment Lengths Section A59 Unit 1 Length feet A60 Unit 1 Length feet Length R to Vertical to 584' 18.5 18.5 Length of Vertical 570'7" to 584' 13.42 13.42 Vertical to Bend South 23.5 21 South to Bend West 16.83 18.17 West to Bend South Past X 15.58 14.58 South to Vertical to Pens 16.75 16.75 Vertical to 588 4.00 4.00 Total 108.58 106.42 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 4 inch drain line A40 1AD-046-4 at the 5694 elevation at match line R. As seen in Figure 14 the 4 line A40 1AD-046-4 runs horizontally from R to where it makes a vertical rise to the 5799 elevation. The length to the vertical bend is 1+29+133+9+9 or 186. The pipe then rises vertically from 5694 to the 5799 elevation or 105.

The 4 drain pipe then runs west parallel to the SFB past match line X sloping up to the 5808 elevation before going through the wall of the Spent Fuel Building. It is 103 from the vertical to match line S. It is 25 from S to X and the line makes its bend 3 feet past X for a total length of 383. It rises 11 providing a hypotenuse of 38.26 feet.

TSD 14-016 Revision 0 Page 29 of 123 Figure 17 - Unit 1 2 Inch Oil Line and 4 Inch Drain Layout Excerpt M-107 SH2 As seen in Figure 8, A40 is 39+14+1+16+9+9 or 91 from Column 23. It is 26 feet to column 21 and the pipe extends another 176 - 123 or 53 for a total length of 91 + 26+ 53 or 404. The pipe also rises a foot to the 5818 making the hypotenuse length 40.35 feet. The pipe then runs west again 11 feet and rises from 5818 to 582 but the slight change does not affect the length. The pipes then rise vertically from the 582 to the 588 elevation for a 6 foot vertical segment. The segment lengths and total lengths are provided in Table 24.

Table 24 -A40 Unit 1 4" Drain Line Segment Lengths Section A40 Unit 1 Length feet Length R to Vertical to 584' 18.5 Length of Vertical 569'9" to 579'9" 10.42 Length from Vertical to SFB Wall Penetrations 38.26 Distance North to Bend West 40.35 West to Vertical through Slab 11.00 Vertical to 588' at Floor Pen 6.00

TSD 14-016 Revision 0 Page 30 of 123 Total 124.52 As seen on Figure 8, Figure 13, Figure 14, and Figure 17, Unit 1 has a 2 inch oil line A42 ODO-100-2 that remains near the 573 elevation. The 2 inch oil line is at the 5694 at match line R. As seen in Figure 13 the pipe runs horizontally from R to where it makes a vertical rise to the 5722 elevation near the 45 degree bend in the SI pipe. Figure 13 and Figure 17 show the length is 1+39+159 or 206. Along this length, the pipe slopes upward from 5684 to 5688 but this does not significantly affect the length. The vertical rise is 5722-5698 or 26. From the 26 vertical it continues west the length to match line S is25-159 to X 25 to 49-3 or 19 past X for a total length of 36 feet. As seen on Figure 17 the pipe slopes upward from 5722 to 5736 over the length past X for a 14 rise which results in a length of 36.02 feet. The line then continues south toward the tank and slopes vertically from the 5736 elevation to the 576 elevation or 26 over the length which is 151-65 or 88 to the center of the tank. With the 26 rise this is 9.02 to the center of the tank. Assuming the pipe from the wall to the tank is removed during the excavation and removal of the tank this is a length of about 46 feet.

Table 25 - Unit 1 2" Oil Line A42 1ODO-100-2" Segment Lengths Section A42 Unit 2 Length feet Length R to 4" Vertical to 569'8" 20.50 Vertical to 572'2" 2.50 Vert to 572'2" West to Vertical Past X 36.02 Vertical to 576' 4.52 Total 63.55 Each Unit has three 1.5 Tell Tale drain lines as seen Figure 8. The penetration and line identifications are A38 1AD-148-1 1/2, A39 1AD-147-1 1/2, A37 1AD-149-1 1/2 for Unit 1 and A53 2AD-148-1 1/2, A54 2AD-147-1 1/2, A52 2AD-149-1 1/2. As seen in Figure 8, these lines are at the 571 elevation at match line R. As seen on M-107 Sheet 2 and the excerpt provided as Figure 18, one of the drain lines in each unit goes vertically into the transfer canal wall between the pool and the canal. The other two go vertically toward the 584 elevation penetrations at the 186 bend.

Figure 18 - Unit 1 and 2 Tell Tale Drain Lines Excerpt from M-107 SH 2 M-106 Section K-K, K1-K1 shows the two Tell Tale drain lines extending vertically without bending to process west with the other pipes.

TSD 14-016 Revision 0 Page 31 of 123 Figure 19 - Excerpt from M-106 Section KK Showing Tell Tale Drain Lines As seen on the Unit 2 side of M-107 SH2, the first drain A54 2AD-147-1 1/2, and A39 1AD-147-1 1/2 elbow into the Fuel Transfer canal concrete is 39+53 to the wall or 9 feet. The 1 foot dimension from the drawing transposed on the wall shows the drain line bends south it at 10 feet. The distance south is 29. The vertical section is assumed to be the 5 feet minimum distance to the bottom of the transfer canal at 576. The line segment lengths are summarized in Table 26.

Table 26 - AD-147-1 1/2 Tell Tale Drains A39 A54 Segment Lengths Section A39, A54 AD-147-1 1/2 feet Length to Bend South 10 Length South to Vertical 2.75 Vertical to 576' 5

Total 17.75 The other four Tell Tale lines are shown in Figure 19. The distance to the vertical bend is 1+29+133+9 or 179. M-106 Section K-K shows the lines continuing vertically past the 584 elevation for a minimum length of 13. The lengths beyond that are undetermined. The lengths for the segments identified are summarized in Table 27.

Table 27 - AD-148-1 1/2 and AD-149-1 1/2 Segment Lengths Section A38, A53 AD-148-1 1/2 feet A37, A52 AD-149-1 1/2 feet Length to Bend South 17.75 17.75 Vertical to 584' 13 13 Total 30.75 30.75 Each Unit has 1 1/2 station air lines as well A41 1SA-014-1 1/2 and A66 2SA-012-1 1/2. As seen on Figure 8 they are at the 5694 elevation. Their layout is highlighted on the M-107 SH2 overhead vie in

TSD 14-016 Revision 0 Page 32 of 123 Figure 20 - Station Air 1SA-014-1 1/2 and 2SA-012-1 1/2 Layout The Unit 1 line 1SA-014-1 1/2 goes vertical to vertical bend that leads to the 583 elevation. The length to the vertical segment is 1+29+14+9 or 186. The vertical segment is from the 5694 to the 583 or 138. The distance of the segment at 583 elevation to S is 103 and 25 to X and 3+16+45+4(9) or 1111 for a total length of 472. The line travels north to the penetration with a length of 39+14+1+16+9 or 84 to Column 23 as seen in Figure 8. The penetration is 16 past column 23 for a total length of 910.

Table 28 - Unit 1 Station Air A41 1SA-014-1 1/2 Segment Lengths Section A41 1SA-014-1 1/2 Length Feet Length to Bend South 18.5 Vertical to 583' 13.67 West to SFB 47.17 North to Pen 9.83 Vertical to 588 5

Total 94.17

TSD 14-016 Revision 0 Page 33 of 123 The Unit 1 Service Water line is a 2-inch diameter line and with a layout parallel to the Unit 1 Station Airline 1SA-012-1 1/2 in Table 28. The Unit 1 Station Air line A44 1SA-014-1 1/2 is shown on Figure 20. The Service Water line travels the same 186 distance to the vertical. The exceptions are that the elevation at R is 5707 and the vertical rise is also to the 584 elevation making that segment 135. The length to the bend into the building is 18 shorter than the station air line at 458 versus 472. The distance north to the penetration in the floor is the slightly greater because the penetration is further from column 23 at 39+110+14+11+9+9 or 9/6 to Column 23 versus 84 for the Station Air. The penetration is 16 past column 23 for a total length of 11. same but the remaining height of the vertical segment is 4 feet rather than 5 feet since the elevation is 584 versus 583.

Table 29 - Unit 1 Service Water A44 1SW-181-2" Segment Lengths Section A44 1SW-181-2" Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 45.67 North to Pen 11.00 Vertical to 588 4

Total 92.58 The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 runs parallel to and between the Station Air A41 1SA-014-1 1/2 and the A44 Service Water line A44 1SW-181-2. The Unit 1 Instrument Air line A46 OIA0-004-1 1/2 is shown on Figure 20. The Instrument Air line travels the same 186 distance to the vertical. The elevation at R is 5707 the same as the Service Water and the vertical rise is to the 584 elevation making that segment 135 as well. The length to the bend into the building is 9 longer than the service water line at 465 versus 458. The distance north to the penetration in the floor is the 8 further as seen in Figure 8 making the length 118. The remaining height of the vertical segment is the same at 4 feet since the 584 elevation is the same. The pipe section lengths are summarized in Table 30.

Table 30 - Unit 1 Instrument Air Line A46 OIA-004-1 1/2" Section A46 OIA-004-1 1/2" Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 46.42 North to Col 23 11.67 Vertical to 588 4

Total 94.00 The Unit 1 A43 Fire Protection line OFP-016-4" penetration is next to and parallels the Service Water line A44 as seen Figure 8 and Figure 20. The distance to the bend vertically is 186 inches. The elevation is also 5707 at R and 584 at the vertical resulting in the same 135 vertical length. The segment west from the vertical to 584 is 9 shorter than the Service Water pipe or 4411. As seen in Figure 8 the distance from column 23 to the penetration is 9 less than the service water making the overall length north to the penetration 103 rather than 11. The remaining vertical to the penetration is also 4 feet. The pipe segment lengths are summarized in Table 31.

TSD 14-016 Revision 0 Page 34 of 123 Table 31 - Unit 1 Fire Protection A43 OFP-016-4" Pipe Segment Lengths Section A43 OFP-016-4" Length Feet Length to Bend South 18.5 Vertical to 584' 13.42 West to SFB 44.92 North to Pen 10.25 Vertical to 588 4

Total 91.08 As seen in Figure 17, there is an unlabeled pentation next to the Fire Protection penetration on M-107 Sheet

2. As explained in the text above Figure 8, the line is identified at Column 24 match line S as 1SF-017-2 and labeled as Demin Water indicating it was a clean water supply to the spent fuel pool. As seen Figure 21 line changes designation from 1DW012-2 to 1SF17-2 at valve 1SF0004 on drawing M-63. The M-69 shows the DW system and the start of that line and references the M-63 drawing for continuation. The M-63 drawing references the M-69 drawing and shows the SF system along with the 1SF0004 valve and the beginning of the 1SF017-2 line.

Figure 21 - Excerpt from M-63 Showing 1SF-017-2" is Demin Water Supply The label on M-107 SH 1 indicates the lines is at the 5834 1/2 elevation. The penetration elevation at R is 5707 resulting in a vertical of 129 1/2. The length to the vertical is the same at 186. The length west from the vertical to bend north is 9 shorter to the floor penetration than the Fire Protection line at 442. The penetration at R is 9 closer to column 23 than the Fire Protection line resulting in the north segment to the floor penetration being 96. The vertical segment toward the floor penetration is longer going from 583 4 1/2to the 588 or 4 7 1/2. The pipe segment lengths are summarized in Table 32.

Table 32 - Unit 1 Fuel Pool Demin Water Supply A29 1SF-017-2" Pipe Lengths Section A29 1SF-017-2" Length Feet Length to Bend South 18.5 Vertical to 584' 12.79 West to SFB 44.17 North to Pen 9.50

TSD 14-016 Revision 0 Page 35 of 123 Vertical to 588 4.625 Total 89.58 Several lines have penetration through the Fuel Handling Building floor east of 1SF-017-2 as seen on M-106 Sheet 2 and Figure 20. These lines are A48 1SF-008-2, A47 1SF-022-3, and A40 1AD-146-4. M-63 shows A48 1SF-008-2to be a Refueling Water Storage Tank line and A47 1SF-022-3 to be a Fuel Pool Demineralizer line indicating they are Class 1 lines. It is 186 to the vertical for both A48 1SF-008-2and A47 1SF-022-3. Both lines are at the 5694 elevation at match line R making the vertical length to 583 138 long. Both lines the travel west parallel to the Fuel Handling Building slab. The distance to match line S is again 25-149 or 103. It is 25 to X with an additional 39 for 1SF-022-3 and 46 for 1SF-008-2 past X to the bend north. The total length of the west segments from the vertical to the bend is 39 for 1SF-022-3 and 399 for 1SF-008-2. The distance of the penetrations at R from column 23 is shown in Figure 8 for 1SF-022-3 it is 39+14+1 or 61. 1SF-008-2 is 16 further south or 77. M-107 SH 2 shows the distance from column 23 south to floor penetrations in 16 for both pipes leading to lengths of 91 for 1SF-022-3 and 83 for 1SF-008-2 to the vertical segment through the slab. Each pipes vertical segment is from 583 to 588 or 5 feet. The line segment lengths are summarized in Table 33.

Table 33 - Unit 1 Fuel Pool A47 1SF-022-3" and A48 1SF-008-2" Pipe Segment Lengths Section A48 1SF-008-2 Length Feet A47 1SF-022-3 Length Feet Length to Bend South 18.5 18.5 Vertical to 583' 13.67 13.67 West to SFB 39.75 39.00 North to Pen 9.08 8.25 Vertical to 588 5

5 Total 86.00 84.42 The Unit 2 Station Air line A66 2SA-012-1 1/2 is shown on Figure 20. It travels the same 186 distance to the vertical and has the same vertical length of 138 to the 583 elevation. Like the other lines, it bends south between S and X. The distance from vertical to match line S is25-149 or 103. The distance to from X to the bend is noted as 3+39 or 69 with another 9 to the line for 76 which give a length from S to the bend of 25-76 or 176. The total length to the bend is 103+176 or 279. As seen on Figure 8 A66 is 39+310+9+9+9 from Column 17 or 910. It is 149 to the pipe from Column 19 with a 26 distance from columns 19 to 17 this is 113 this plus the 910 to column 17 is 211. From there it turns west again and parallels the foundation which extends to just past match line U. Piping past the foundation is assumed to be buried pipe that will be removed. It is 149 to X then 25 to U then 39 to the end of the foundation for a total length of.436 The remaining line past the foundation will be removed. The Unit 2 Station Air segment lengths are summarized in Table 34.

Table 34 - Unit 2 Station Air A66 2SA-012-1 1/2 Segment Lengths Section A66 2SA-012-1 1/2 Length Feet Length to Vertical West 18.5 Vertical to 583' 13.67 Length West to Bend South 27.75 South from Bend Past S to Bend West.

21.08 Length West to End of Foundation 43.5 Total 124.5

TSD 14-016 Revision 0 Page 36 of 123 Each Unit has Service Water supply lines A65 2SW-243-3 parallels the Unit 2 Station Air line A66 2SA-012-1 1/2 in Table 28. The exceptions are that the elevation at R is 5707 and the vertical rise is to the 584 elevation making that segment 135. The distance west to the bend from the vertical is 9 further at 286.

The distance of the penetration from column 17 is 39+110+14+11+9+9+9 or 103 instead of 910 for A66 making the length of the segment south from the bend 216. The length west to the end of the foundation is 9 shorter or 429. The segment lengths are summarized in Table 35.

Table 35 - Unit 2 Service Water A64 2SW-243-3" Line Segment Lengths Section A65 2SW-243-3" Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 28.5 South from Bend Past S to Bend West.

21.50 Length West to End of Foundation 42.75 Total 124.67 The Unit 2 Aerated Drain line A62 2AD-146-4 parallels the path of the Service Water 2SW-243-3 over much of its length. It runs next to 2SA-012-1 1/2 whose segment lengths are shown in Table 34. The length to the vertical is 186. As seen in Figure 8, the penetration is at the 5707 Figure 20 shows the elevation of the vertical at 584 making the length 135. The pipe then runs west to where it bends north. The distance west is 9 less than 2SA-012-1 1/2 length or 27. The penetration at R is 39+110+14+11+9+9 or 96 to column 17. The additional length is26-149 or 113 for a total length of 209 feet. It then proceeds west 69 to match line X and 25-26 or 226 for a total length of 293. The distance from the bend south to the penetration is 149+2 or 169. The vertical segment to 588 elevation is 4 feet. The pipe section lengths are summarized in Table 36.

Table 36 - Aerated Drain A62 2AD-146-4" Pipe Segment Lengths Section A62 2AD-146-4 Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 27 South from Bend Past S to Bend West.

20.75 Length West After Bend 29.25 Length South 16.75 Vertical to 588' 4

Total 129.67 As seen on Figure 8, there is no ODW-008-3 line at the Unit 2 penetrations at R. There is a 2DW-014-3 and a 2DW-008-3. There appears to be incorrect labeling of the lines on M-107 Sheet 2 as seen in Figure 22 since 2DW-014-3 and 2DW-008-3 cannot be the same line and have two different penetrations at R21 in Figure 8.

TSD 14-016 Revision 0 Page 37 of 123 Figure 22 - Unit 2 Pipe ID Labeling Change on M-107 Sheet 2 Therefore, the lines segment lengths will be assigned to the 2DW-014-3 and 2DW-008-3 as shown in Figure 22. Both lines run parallel to 2AD-146-4. Both are 186 to the vertical. 2DW-014-3 is at the 5707 elevation at match line R and 2DW-008-3 is at the 5694 elevation as shown on Figure 8. They are both assumed to be at the 583 elevation as indicated in Figure 13 which shows two 3 lines at K1-K1. This results in a vertical rise length of 125 for A63 2DW-014-3 and 138 for A61 2DW-008-3. The 2DW-008-3 segment west from the vertical rise to the bend south is 9 shorter than 2AD-146-4 at 263. 2DW-104-3 is an additional 9 shorter at 256. As seen in Figure 8, 2DW-014-3 is 9 closer to column 17 that 2AD-146-4 or 20 2DW-008-3 is 39+17+9+16+9+9 or 91 with an addition 26-149 from column 17 this makes the length 204. From the bends, south the lines turn west for a length where 2DW-014-3 is 9 shorter than 2AD-146-4 or 286. 2DW-008-3 is 9 shorter than 2DW-014-3 or 279. The length south to the vertical leading to the floor penetration is the same as 2AD-146-4 or 169. The vertical to the 588 foot elevation is 5 feet. The calculated line segment lengths are provided in Table 29.

Table 37 - Unit 2 Demin Water Lines A63 2DW-014-3" and A61 2DW-008-3" Pipe Segment Lengths Section A63 2DW-014-3 Length Feet A61 2DW-008-3 Length Feet Length to Vertical West 18.5 18.5 Vertical to 583' 12.42 13.67 Length West to Bend South 25.5 26.25 South from Bend Past S to Bend West.

20.00 20.33 Length West After Bend 28.5 27.75 Length South 16.75 16.75 Vertical to 588' 5

5 Total 126.67 128.25 OCT-61-2 at penetration A58 parallels 2DW-014-3 for most of its length but appears to terminate outside the SFB wall. It is the line from the Decontamination Pad to the Chemical Drain Tank making it a MARSSIM Class 1 line.

TSD 14-016 Revision 0 Page 38 of 123 Figure 23 - A58 OCT-061-2" Layout Near Point of Termination It is 186 to the vertical bend. As seen on Figure 8, A58 OCT-061-2 is at the 5694 at the match line R penetrations making the vertical to the 583 138. The westward run to the bend south is 9 shorter than 2DW-014-3 or 279 long. As seen in Figure 8 it is 9 closer to column 17 than 2DW-008-3 or 84 which makes the total length with 26-149 added a total of 197. The distance west to the termination of the line segment is 4 x 9 or 3 with an additional 3+3.75+3.5 as seen in Figure 23 for a total of 133. The calculated segment lengths are provided in Table 38.

Table 38 - A58 OCT-061-2" Line Segment Lengths Section A58 OCT-061-2 Length Feet Length to Vertical West 18.5 Vertical to 583' 13.67 Length West to Bend South 24.75 South from Bend Past S to Bend West.

19.58 Length West After Bend 13.25 Total 89.75

TSD 14-016 Revision 0 Page 39 of 123 Figure 24 -Unit 2 Waste Discharge Line OWD-059-2 1/2" Path As seen in Figure 24, the Unit 2 Waste Discharge line A64 OWD-059-2 1/2 parallels OCT-061-2. As shown in Figure 8, the line is at the 5707 elevation at the penetrations at R17. The distance to the vertical bend is 186. The pipe rises from 5707 elevation to the 584 elevation or 135. The section west is 9 shorter than OCT-061-2 or 24. The penetration is 9 closer to column 17 than 2DW-014-3 or making the total length of the south running segment 193. The segment west to the second bend south is 5 x 9 or 39+3+39+14+3 or 276. It then travels west to the vertical bend to the penetration 149+176+123 or 446. The vertical to the 588 is 4 feet. The pipe section lengths are summarized in Table 39.

Table 39 - Unit 2 Waste Disposal Line A64 OWD-059-2 1/2" Pipe Section Lengths Section A64 OWD-059-2 1/2 Length Feet Length to Vertical West 18.5 Vertical to 584' 13.42 Length West to Bend South 24 South from Bend Past S to Bend West.

19.25 Length West After Bend 44.5 Vertical to 588' 4

Total 123.67 As seen in Figure 25, the remaining Unit 2 lines all run parallel to OWD-059-2 1/2 and terminate in the same area. A57 0SF-012-3", A55 2SF-008-2", A56 2SF-022-3".

TSD 14-016 Revision 0 Page 40 of 123 Figure 25 - OSF-012-3", 2SF-022-3" and 2SF-008-2" Layout Figure 26 from excerpted from drawing M-63 shows that 0SF-012-3"feeds the Auxiliary Building Hold-Up Tanks (HUTs), 2SF-008-2" provides water to the Spent Fuel Pool supply and return from the Unit 2 Refueling Water Storage Tank, and 2SF-022-3" to the Unit 2 Spent Fuel Water Demin making all these lines Class 1 MARSSIM lines.

Figure 26 - M-63 Excerpt for OSF-012-3", 2SF-008-2", and 2SF-022-3" Lines

TSD 14-016 Revision 0 Page 41 of 123 As seen in Figure 20, each line is 186 from the penetrations at R17 to the vertical bend. As seen in Figure 8, the penetrations are on the same elevation as OCT-061-2 and like OCT-061-2 rise to the 583 elevation or 138. 2SF-008-3 has a length west from the vertical that is 9 shorter than OCT-061-2 or 24. The west segment length from the vertical of 2SF-022-3 is 9 shorter than 2SF-008-2 at 233 and OSF-012-3 is 26 shorter than 2SF-008-2 or 209. As seen in Figure 8, A55 2SF-008-2 is 9 closer to column 17 than OCT-061-2 or 1810 when the 113 from column 17 is included. 2SF-022-3 is 16 closer to column 17 than 2SF-008-2 or 174. OSF-12-3 is 9 closer than 2SF-022-3 or 167. As seen in Figure 25, the lengths west after the first bend south for OSF-12-3 is 26 +6+3+39+3 or 183. 2SF-22-3 is 6+3+39+3+9 or 166 and 2SF-008-2 is 6-9+3+39+3+9+9 for 166 also. The length south to the vertical to the penetrations is the same length as 2CC-078-10 and 2CC-080-10 or 169 and the vertical from the 583 to 588 is 5. The pipes segment lengths are summarized in Table 40.

Table 40 - Unit 2 Spent Fuel Pool Water Lines A55 2SF-008-2", A56 2SF-022-3", A57 0SF-012-3" Section A55 2SF-008-2 Length Feet A56 2SF-022-3 Length Feet A57 0SF-012-3 Length Feet Length to Vertical West 18.5 18.5 18.5 Vertical to 583' 13.67 13.67 13.67 Length West to Bend South 24 23.25 20.75 South from Bend Past S to Bend West.

18.83 17.33 16.58 Length West After Bend 16.5 16.5 18.25 Length South to Floor Pen Vertical 16.75 16.75 16.75 Vertical to 588' 5

5 5

Total 113.25 111 109.5 The Containment to Auxiliary Building pipe chase penetration shown in Figure 1 are already attributed to the Containments whose walls form the interior wall of the Auxiliary Building Pipe Chase as well. The Containment Sump piping at M-16 and M-24 in Figure 3 are also attributed to the Containment. The next penetration is a 14 inch sleeve through the 2 foot thick wall between the Aux Building and a Main Steam Tunnel at the 571 elevation as seen on Attachment B near row H column 10. There is a similar sleeve on the opposite wall at H30. As seen on Attachment B, there is a 10 inch Fire Protection Line OFP-12-10 at H10 that is shown on Drawing M-165 and M-187. Near G10 there are two OSW-008-12 lines as seen on drawing M-185 and Attachments A & B.

As seen on Attachment A and B there are many penetrations along the wall at Row G between the Turbine Building and Auxiliary Building. All penetrations labeled as open sleeve are assumed to have the pipe removed, leaving an opening equal to the outer diameter of the pipe. Attachment B shows penetrations at G13 consisting of a 3 waste disposal line OWD-31-3 from Drawing M-165 and M-171.

There are two 12 Service Water Supply lines to the Diesel Generator Heat Exchangers at J9 A27, A28 and J31 A30, A31as seen on Attachments A and B. As seen in Figure 27, these lines pass under the steam tunnels for 21 feet, then under the tunnel floor towards G for 143 and 1`23 plus the 219 of H to G. Detail C of M-106 (provided as Figure 28) shows an elevation change from 554 9 and 5534 at G to 567 6at J. This is an additional 142 and 129 making the total lengths of the lines 71 2 and 69 9 or 837 and 833 inches respectively. As seen in Figure 28, the horizontal runs under the Main Steam Tunnel are at 5636, the floor is at 570 so the pipes are 66 below the floor in the fill material below the slab. The horizontal run under the Diesel Generator floor are at the same elevation with the floor at the 5676. The pipes horizontal runs are 4 feet below the floor. Thus, none of the horizontal runs of A27, A28, A30, or A31 are with 8 of the surface of any floor.

TSD 14-016 Revision 0 Page 42 of 123 Figure 27 - 12" Service Water Supply to Diesel Generator Heat Exchangers from M-106.

Figure 28 - M-106 Detail C Side View of 12" Service Water Supply to Diesel Generator Heat Exchangers Attachments A & B show the 48 in Service Water Supply penetrations C26 and C29. As seen on drawings M-168 and M-169 two 48 inch Service Water Supply Header pipes, OSW-13-48 (C29) and OSW-14-48 (C26), exit the Auxiliary Building at elevation 5498 at G19 and G21. As shown on Figure 39 excerpted from M-103 and M-104 the pipes run east 104 beneath the 560 floor from G to A through the Turbine

TSD 14-016 Revision 0 Page 43 of 123 Building slab where they exit the Turbine Building Oil Room wall at A19 and A21 at 5498 as seen in Figure 38. Figure 48 shows that they exit the Turbine Building slab 6 feet before match line A. Thus, the distance from G to the slab exit is 171.5 feet as seen on Figure 39. They then travel 8 feet east to the pipes center line of the vertical rise. They then rise vertically from 5498 to the 579 elevation (i.e., 294) making the buried pipe length 37 4. The pipes continue eastward to the Crib House wall as seen on M-106 and Figure 48. As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 579 will be cut and removed leaving the buried vertical sections. Drawing M-105 shows the lines traversing east where they pass through the Crib House wall at AA19 and AA21. M-106 and Figure 38 shows it is 2 feet from the center line of the pipe to A. M-105 shows the distance from A to AA as 50 feet for a total of 52 feet that will be removed. M-106 and M-105 shows the Crib House wall to be 4 feet as seen in Figure 48.

Table 41 - Service Water Supply Header Pipe Lengths C26 & C29 Segment Category Drawing OSW-013-48" and OSW-14-48" Feet Auxiliary Wall Column G Embedded M-103, M-104 1.5 Column G to TB Slab Exit Near Column A Embedded M-103, M-104 170 East to Vertical Rise at Column A Buried M-106 8.00 Vertical Rise at Column A Buried M-106 29.33 Totals 208.8 Embedded 171.5 Buried 37.33 The 4 foot penetration length in theCrib House foundation is included in the Crib House Section.

The Auxiliary Building Aerated Drains remaining in the slab were surveyed and had their lengths measured in Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016 (4).

Because the inventory of Auxiliary Building Penetrations also includes those coming from the Unit 1 and Unit 2 Containments, a breakout list of the inventory which is a subset of the Attachment F complete inventory is provided in Attachment I. A summary of all the Auxiliary Building penetrations including those covered in the containment sections for both Units are provided in Table 42.

Table 42 - Summary of Auxiliary Building Affiliated Penetrations Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 482.89 585.06 72.34 Buried Pipe 126.32 92.68 6.74 Open Sleeve 199.54 256.67 37.44 Pipe in Sleeve 157.02 235.71 28.16 Bld to Yard Pen 924.37 363.69 161.87 Buried Pipe 924.37 363.69 161.87 Grand Total 1407.26 948.75 234.21

TSD 14-016 Revision 0 Page 44 of 123 4.5.

Turbine Building Penetrations and Piping As seen on Attachment B and Figure 29 there are 10 diameter Fire Protection line penetrations in the north and south wall of the Diesel Generator Buildings at 583 6 at J5 and J35 as show in Drawing M-106. These lines and penetrations are part of the buried pipe inventory. (5)

Figure 29 - Diesel Generator Fire Protection Line from Drawing M-106 The pipes are assumed to be cut flush with the interior and exterior of the 3 foot thick Diesel Generator Building north and south walls.

Table 43 - Penetration T35 at J5 and T36 at J35 of M-106 Length to 10" FP in Wall Section Length feet Elevation Pen 35 Sleeve 3

583.5 Pen 36 Sleeve 3

583.5

TSD 14-016 Revision 0 Page 45 of 123 There are 4 inch diameter Diesel Oil lines 2DO-006-4 (T68) and 1DO-001-4 (T75) that go through the Turbine Building North and South Walls at G5 and G35 at the 5853 elevation. M-104 show T68 going through a 4 foot thick wall, then traveling buried 45 6 to a where it bends 2 feet East it then rises out of the ground to the 593 elevation. The pipes are to be cut flush with the exterior anterior of the wall laving 4 foot lengths.

Figure 30 - Unit 2 Diesel Oil Fill Line Penetration and Buried Section on M-104

TSD 14-016 Revision 0 Page 46 of 123 Figure 31 - Unit 1 Diesel Oil Fill Line Penetration and Buried Section on M-103 Drawing M-104 shows three 8 sleeves through the 18 wall between the Turbine Building and Unit 2 Diesel Generator Building at G5-G10. Drawings M-562 and M-663 show only two oil lines 2DO-004-4" (T69) and 2DO-001-4" (T70) going through the penetrations. Although there appears to be no pipe through the sleeve at T70a, it is included in the inventory.

TSD 14-016 Revision 0 Page 47 of 123 Figure 32 - Unit 2 North Diesel Oil Penetrations There are three Unit 1 oil lines between G32-34 in M-103 and M-214. These are penetrations T72, T73, T74.

Figure 33 - Unit 1 South Diesel Oil Penetrations

TSD 14-016 Revision 0 Page 48 of 123 These are routed through the 18 thick wall between the Diesel Generator and Turbine Building in 8 sleeves. M-104 shows 3 8 sleeves between G32 and G35. The pipes will be removed leaving the 8 sleeve openings.

As seen in Figure 27 there is also a 14 diameter sleeve passing through the Diesel Generator Building and Steam Tunnel walls between H&J at columns 10 and 31 (T34b, T34a). As seen on Attachments A and B the walls are 2 feet thick.

The 16 Service Water Return lines T32 and T33 from the Diesel Generator Heat Exchangers are also embedded below the Diesel Generator Building floors as seen in Figure 27. These connect to the 48 Service Water Supply Header on Drawing M-103 and M-104. A graphic with dimensions for U1 T32 pipe is provided as Figure 34.

Figure 34 - T32 Unit 1 16" Service Water Supply to Diesel Generator Heat Exchangers As seen on M-106 the Diesel Generator Floor is at 5676 and the pipe below it is at 5636 resulting in a vertical rise to the floor penetration at J31 and J9. The horizontal run is 4 feet below the Diesel Generator Building floor. There is also a vertical rise at G31 and G9 from 55310 to 5636 or 9.67 feet. The line runs north under the Turbine Building floor at 55310 which is 62 below the 560 elevation floor. The length from J to G is 42. M-106 shows the floor penetrations at J31 and J9. T32 at J31 is 3+19+ 22 3/8 from J resulting in a length of 35.05 feet. T33 at J9 is inset 3+19+111 from J for a length of 35.33 feet. The runs eastward and north south are found on M-106, M-103, M-104. These total lengths are 183 feet as seen in Table 44. The portion of the pipe under the Diesel Generator building is below the slab in soil.

Table 44 - Segment Lengths for Embedded 16 Service Water Return Lines T32 and T33 Segment T32 U1 Feet T33 U2 Feet

TSD 14-016 Revision 0 Page 49 of 123 Vertical 1 Under DG 4

4 Vertical 2 Under DG 9.67 9.67 Length on M-106 35.05 35.33 Length East on M-103 & M-104 16 16 Length North South on M-103 & M-104 118.75 118.75 Total Length 183.5 183.8 All the penetrations on the East Wall of the Turbine Building are concentrated in and around the Oil Room at the centerline of the building. The Unit 2 north penetrations are provided on M-104 and an excerpt from the drawing is provided as Figure 35. The Unit 1 south penetrations are provided on M-103 an excerpt from the drawing is provided as Figure 37. The buried portions of these pipes will be removed with the exception of the 48 inch Service Water Headers C26 and C29, the 20 inch and 4 inch Condensate pipes T103 and T105.

These include spare, 10, 12 and 14 spare penetrations at C16 (T91, T92, T93) and C24 (T99, T100, T101) as seen on Attachments A and B as well as Figure 35 and Figure 37. As seen in Figure 35, Figure 37, and Detail B of M-106 the spare penetrations are 5 feet long extending 6 inches past the 4 foot thick wall on either side. The remaining pipes are assumed to be cut flush with the interior and exterior walls leaving 4 feet of embedded pipe. M-104 shows T102 and T95 running at the 5569 elevation to match line D.

TSD 14-016 Revision 0 Page 50 of 123 Figure 35 - Turbine Building East Wall Penetrations - North

TSD 14-016 Revision 0 Page 51 of 123 Figure 36 - T95 and T102 Buried and Embedded Sections As seen in Figure 36, the embedded portion of T95 from the exterior of the wall at the back of the Oil Room to the penetration through the 560 elevation floor is 10+25+354+26 or 7210. The vertical through the 560 floor is 560-5569 or 33. T95 then travels an estimated 13 feet in the

TSD 14-016 Revision 0 Page 52 of 123 soil until it rises vertically from the 5569 to the 586 elevation of 118.33 feet as seen in Table 45.

The embedded length of T102 2 foot of wall + 354+26 or 3910.

Table 45 - Estimated Lengths of T95 and T102.

Line Segment T95 T102 560' Vertical from 556'9" 3.25 3.25 560' Pen to Back of TB 72.8 39.8 Back Wall To Vertical in Soil 13 6

Vertical to 586' in Soil 29.25 29.25 Total 118.33 78.33 Embedded 76.08 43.08 Buried 42.25 35.25 Figure 37 - Turbine Building East Wall Penetrations - South A 20 inch Condensate line and a 4 inch Condensate Pump Recirc line penetrate the wall at A21 5569 and 5583 elevation as shown on M-105 and M-103. The 20 inch Condensate Line supplies the Alternate Feedwater Pumps as shown in drawing M-105 Sheet 2 Section C-C. The pipe exits from the Turbine

TSD 14-016 Revision 0 Page 53 of 123 Building slab at elevation 5569 into the soil then travels vertically to the 586 elevation. This line is not included in the TSD 14-015 Attachment 1 listing of buried pipe. M-103 and M-106 Section A-A show the top view and the side view of the pipe existing the Turbine Building these sections are provide in Figure 38.

As seen in Figure 38 and Figure 37, the horizontal sections traversing from the Turbine Building to the Crip House at the 586 will be cut and removed leaving the buried vertical sections.

Figure 38 - 20 Inch Condensate to Alternate Feedwater Pumps Penetration Exiting Turbine Building Drawing B-559 shows the Oil Room wall exterior is 11 feet from row B which is 14 feet from Row A. As seen in Figure 38, the pipe exits the building at a 45 degree angle this means the pipe exiting the building foundation then bends 90 degrees upward at two feet from Row A. This results in a 69 base and 12 height resulting in a hypotenuse length of 13.77 feet from the 20 to 18 reducer within the wall to the vertical bend upward to the 586 elevation. The vertical pipe length from the 5569 to 586 or 29.25 feet. The buried pipe section of the Condensate from the exit of the Oil Room foundation to the cut line is shown in Table 46. The 4 Condensate line parallels the 20 line but exits the foundation 1.5 feet higher at 5583 or 19 below the 560 floor. Resulting in a vertical length of 279. As seen in Figure 39, the embedded portion in the TB foundation is shown on M-103. Shortly after entering the Turbine Building foundation they run through the slab and emerge on the west side of the 560 floor at G22. M-103 shows 180 feet from column A to G. The 18 T103 penetration is 56 below G making it 1746 long. Other dimension show the distance from the centerline of the pipe forming a 45 degree triangle at 129 long.

TSD 14-016 Revision 0 Page 54 of 123 Figure 39 - Embedded 4" and 18" Condensate Pipes T103 and T105

TSD 14-016 Revision 0 Page 55 of 123 This results in a length of 1619 from A to the 45 degree bend for the 18 pipe. The 4 inch pipe is offset by 2 feet from the 18 pipe resulting in a length of 1599 from A to the 45 degree bend. The 45 degree bend section of each pipe is the hypotenuse of a 45 degree triangle with 129 sides or 18.03 feet. The 4 inch diameter pipe vertical section to the floor is 19 and the 18 pipe vertical section is 33. The lengths, diameters, surface areas and volumes are summarized in Table 46. As seen in Figure 39, the 4 Condensate line T105 runs beneath the floor at the 5583 elevation making it 19 below the floor. The 18 Condensate line T103 runs under the floor at the 5569 elevation making the top of the pipe at the 5576 elevation or 26 below the floor. T106 runs under the floor at the 5569 level, 33 below the 560 floor.

Table 46 - Calculated T105 and T103 Condensate Pipe Lengths, Surface Areas and Volumes Length ft SA ft2 Vol ft3 Buried Pipe Section T103 20" Feet T105 4" Feet 20" 4"

20" 4"

Wall thickness Inches 0.594 0.237 Diameter feet 1.57 0.29 Wall to 90 13.77 13.77 67.81 12.71 26.58 0.93 Vertical 29.25 27.75 144.06 25.62 56.46 1.88 Total Buried 43.02 41.52 211.86 38.33 83.03 2.82 Embedded Pipe Section 18" Feet 4" Feet 18" 4"

18" 4"

Wall thickness Inches 0.562 0.237 Diameter feet 1.41 0.29 Horizontal 161.75 159.75 714.63 147.47 251.25 10.83 Hypotenuse 18.03 18.03 79.66 16.64 28.01 1.22 Vertical 3.25 1.75 14.36 1.62 5.05 0.12 Total Embedded 183.03 179.53 808.66 165.73 284.31 12.17 Totals 226.05 221.05 1020.52 204.05 367.34 14.99

TSD 14-016 Revision 0 Page 56 of 123 Figure 40 - 12" Condensate Transfer Make-Up Pump Penetration T106 from M-103 The 48 Service Water Supply Headers exiting between B & A at Columns 19 and 21 from under the building at 549 are discussed in the Crib House section.

Aerated Drain piping from equipment drains, floor drains, and sump piping remains in the end state Turbine Building slab below the 560 elevation. The estimated piping lengths and diameters were inventoried in the preparation of FSS Plan 06105B Turbine Building Embedded Piping Drawings used in developing the FSS Plan are as follows: (6)

B-452 Turbine Building Plumbing Basement Floor Plan Unit 1 B-454 Turbine Building Plumbing Diagram Basement Floor Plan Unit 1 B-471 Turbine Building Plumbing Basement Floor Plan Unit 2 B-473 Turbine Building Plumbing Diagram Basement Floor Plan Unit 2 M-103 Zion Station Unit 1Turbine Building Piping, Misc. Piping in Structure Embedded system piping surveyed by this survey plan included the floor drain and equipment drain systems below the 560 elevation of the Turbine Building. These systems consist of inputs and connecting piping that terminates at one of four drain sumps (Unit 1 Equipment Sump, Unit 2 Equipment Sump, Turbine Building Floor Sump and the Fire Sump) beneath the 560 el. floor.

The floor drain system on the 560 el. consists of 26 floor drain inputs, the floor drains from the Clean and Dirty Oil Storage Tank Rooms, the continuation of the Emergency Diesel Generator Fuel Oil Storage Tank Room floor drains from the 567 el., and the continuation of the floor drain systems from the Turbine Building 592, 617 and 642 elevations from where they enter the floor of the 560 el. to their connection to

TSD 14-016 Revision 0 Page 57 of 123 the embedded drain piping (approximately 1,250 linear feet of varying diameter drain pipe which connects all floor drain inputs) and terminating at either the Turbine Building Sump or the Fire Sump.

Also included is the Unit 1 equipment drain system consisting of input associated with components located on the 560 and 562 elevations and the common area between Units 1 and 2, the continuation of the Unit 1equipment drains from the 642, 617, and 592 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 300 linear feet of varying diameter equipment drain system piping) terminating at the Unit 1 Equipment Sump.

Also included is the Unit 2 equipment drain system consisting of input associated with components located on the 560 562 elevations, the continuation of the equipment drains from the 642, 617 and 592 elevations of Unit 2 from where they enter the floor of the 560 el. to their connection to the embedded equipment drain piping (approximately 200 linear feet of varying diameter equipment drain system piping) terminating at the Unit 2 Equipment Sump.

The polishing filter system drains consist of 2 inputs located in the common area, connected to 2, separate 10 diameter pipe systems that terminate at inputs to the fire sump, total length of 10 diameter pipe is approximately 180 linear feet.

The varying pipe diameters are apparently related to progression in the number of inputs to the different systems (more inputs, increased pipe diameter). The surveys were performed at the discharge end of the pipes in the sumps. During performance of the survey, pipes were found to be larger in diameter than what was identified in the survey plan based on available drawings (6vs 4 and 8vs 6).

The estimated length of pipe was based on the drop from the 560 el. to the lateral pipe run (approximately

4) plus the estimated lateral run of the pipe base on turbine building column line dimensions, as the drawings are difficult to read. In some cases, the total length of a given diameter of pipe could not be determined consequently an exaggerated total length was used in order to build conservatism into the survey plan.

The estimated pipe section diameters and lengths are summarized in Table 47.

Table 47 - Estimated Turbine Building Drains from FSS Plan 06105B Turbine Building Imbedded Piping Penetration No.

Description Pipe Size inches OD Length Feet T147 U-1 Equip Drain Sump, 6 pipe West Wall 6

200.00 T148 U-1 Equip Drain Sump, 6 pipe North Wall 6

100.00 T149 U-2 Equip Drain Sump, 6 pipe West Wall 6

200.00 T150 Floor Drain Sump, West-most 6 pipe on North Wall 6

100.00 T151 Floor Drain Sump East-most 6 pipe on North Wall 4

100.00 T152 Fire Sump, South-most 6 pipe on West Wall 4

150.00 T153 Fire Sump, North-most 6 pipe on West Wall 8

450.00 T154 Fire Sump, West-most 8 pipe on North Wall 8

450.00 T155 Fire Sump, West-most 10 pipe on North Wall 10 80.00 T156 Fire Sump, East-most 10 pipe on North Wall 10 100.00 The list of Turbine Building affiliated penetrations and piping other than the drains is provided in Attachment J. The calculated lengths, surface areas and void spaces are summarized in Table 48.

TSD 14-016 Revision 0 Page 58 of 123 Table 48 - Summary of Turbine Building Affiliated Penetration and Piping Lengths, Surface Areas and Volumes.

Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 291.56 354.61 43.79 Buried Pipe 204.69 222.34 19.46 Open Sleeve 86.87 132.27 24.33 Bld to Yard Pen 235.59 726.53 13.46 Buried Pipe 158.58 683.81 11.42 Open Sleeve 4.57 4.27 0.32 Pipe in Pen 72.44 38.45 1.72 Grand Total 527.15 1081.14 57.24 The Turbine Floor drain piping is summarized in Table 49. The inventory of piping is provided at the end of Attachment J.

Table 49 - Summary of Turbine Building Drain Lengths, Surface Areas and Void Space Volumes Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld Pen 588.26 302.43 13.13 Embedded Pipe 588.26 302.43 13.13 Grand Total 588.26 302.43 13.13 4.1.

Circulating Water Intake Piping The Circulating Water Supply to the Condensers consist of embedded pipe through the Crib House Wall, buried pipe from the Crib House to the Turbine Building Foundation and Embedded pipe from the Turbine Building foundation as seen in Attachment C. The section below the condensers is shown in Figure 41.

Assuming the 9 foot diameter supply pipes (T109, T110, T120, T121 in Unit 1 and T123a, T123, T133, T134 in Unit 2) are cut above the water table at the 580 elevation and grouted. The floor elevation is 572. The average length to the 12 foot diameter line below 572 to the connection to the 12 foot diameter pipe is conservatively estimated at 26 since some of the surface area extends below the top of the pipes at the 570 elevation. Thus, their total embedded length is 2.5 feet. Notation on M-100 which is retained in Attachment C shows a 1 inch pipe wall thickness for the 9 diameter piping.

The 36 diameter manways to the 12 Diameter Circulating Water Supply line (T83, T85, T87, T88) are 9 feet long if they are cut flush with the concrete as seen in in Figure 41. Figure 41 also shows that each of the four (T111, T122, T143, T124) 12 foot diameter pipes below the condenser. These pipes have a 1.25 inch wall thickness as seen in M-100.

TSD 14-016 Revision 0 Page 59 of 123 Figure 41 - Circ Water Intake Supply to Condensers Each of the 4 pipes has a spherical head whose surface area is calculated using Equation 3.

Equation 3 - Surface Area of Spherical Cap

= 2 Where; r = is the inner radius or 70.75 inches h = is the inner height of 22.75 inches This results in an inner surface are of 10,113.18 square inches for each end bell.

The volume is calculated using Equation 4.

TSD 14-016 Revision 0 Page 60 of 123 Equation 4 - Volume of Spherical Cap

=

6 (32 + 2)

Where a equals the inside radius or 70.75 inches and h the inside height or 22.75 inches. The end cap surface areas and volumes are shown in Table 50.

Table 50 - End Cap and Pipe Surface Areas and Volumes for 12 Foot Diameter Circ. Water Supply Piping Under Condensers End Bell Pipe Totals Section r inches h inches SA in2 V in3 Length inches SA in2 V in3 SA in2 V in3 T111 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T111b 70.75 270 1.2002E+05 4.2459E+06 1.2002E+05 4.2459E+06 T122 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T122b 70.75 1002 4.4542E+05 1.5757E+07 4.4542E+05 1.5757E+07 T143 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T143b 70.75 1002 4.4542E+05 1.5757E+07 4.4542E+05 1.5757E+07 T124 70.75 22.75 10113.18 185042 547.5 2.4338E+05 8.6097E+06 2.5350E+05 8.7947E+06 T124b 70.75 270 1.2002E+05 4.2459E+06 1.2002E+05 4.2459E+06 Drawing B-61 shows a distance of 316 from match line E to the Turbine Building wall just beyond match line D. The embedded length of T111, T122, T143, T124 are as seen on Attachment C. The lengths embedded in concrete are 316+ 87.5 + 56 or 457.5 which is 547.5 inches. As seen on Attachment C the buried portions of pipes T111 and T124 are 54-316 or 367.5 which is 270 inches. The lengths of T122b and T143b are 115-316 or 1002 inches.

Section T112 and T125 cut diagonally South and North Section 4-4 on drawing M-100 provides a side view of the intersection with a 9 long expansion to a 17 foot diameter. M-100 shows the dimension from T111 to the intersection below is 115 minus 54 feet or 61 feet with an estimated 4 feet to the intersection below the joint for an opposite length of 65 feet. The base length is also shown on M-100 as 65 7.75 inches. This results in a hypotenuse length of 925. Minus 14 to the 17 expansion and 9 for the expansion joint provides a length of 695.

TSD 14-016 Revision 0 Page 61 of 123 Figure 42 - Side View of Expansion Area for T112, T113, T114 and T125, T126, T127 The average outside diameter of the expansions at T113 and T126 is 146 with a 1.5 inch wall thickness this is an interior diameter of 143 over a 9 length.

Sections T114 and T127 are 17 OD pipes with 1.5 walls for an inner diameter of 169. M-100 shows the base is 88 4.25 inches minus 162 or 722.25. It shows an opposite of 50 feet minus the estimated 4 feet for the upper point and an estimated 10 feet for the lower point equaling 36. The resulting hypotenuse is 808. As seen on section T114 of Attachment C there is an addition 14 to the 12 to 17 expansion for a total length of 948.

The 17 to 9 reducers at T115 and T128 are approximately 83 long with an average diameter or 13. With a pipe wall thickness of 1 the average inside diameter is 1210. The length of the straight sections is estimated at 6 feet with a 9 foot outside diameter and 810 inside diameter.

Table 51 - Estimated Lengths, Surface Areas, and Volumes for Section T115 and T128 Sect Dia in Wall Thick ID Length in SA in2 V in3 Reducer 156 1

154 99 4.79E+04 1.84E+06 Straight 108 1

106 72 2.40E+04 6.35E+05 Total 171 7.19E+04 2.48E+06 T116 and T129 are approximately 196 long. T117 and T130 are approximately the same length as T115 and T128 at 171 inches long. T118 and T131 are 10 to 9 reducers that are 83 long. T119 and T132 are approximately 14 feet long and have a 10 foot outer diameter.

There are Circulating Water Intake Pipes that connect to the Forebay Drawing B-49 shows a 16 diameter at the exit point from the Forebay. Drawing M-2 shows approximately 50 feet to the shoreline.

TSD 14-016 Revision 0 Page 62 of 123 Figure 43 - Distance to Shoreline from Discharge Structure Valve House M-2 The summary of the Circulating Water Intake and Supply section noted above and shown in Attachment C have inventories listed in Attachment O. The lengths, surface areas and void space volumes are summarized in Table 52.

Table 52 - Summary of Circulating Water Intake Piping Lengths, Surface Areas, and Void Space Volumes Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Circ Water Intake 384.27 4412.09 4393.19 4.2.

Circulating Water Discharge Piping Circulating Water Discharge piping in the Turbine Building consists of a 48 inch (T75, T76) and 36 inch stand pipe (T84, T86), a 36 inch manway entrances to the Discharge Tunnel (T135, T136) and two 12 foot interior diameter discharge pipes from the condenser for each Unit (T77, T78, T80, T81). The top view is provided in drawing M-15, the side view is from drawing B-100 as shown in Figure 44 and in Figure 45.

Penetrations T75and T77 are the Unit 2 Circulating Water Discharge Stand Pipe located at F9 and F31 in the Turbine Building as shown in Attachments A, B, C and Figure 44. A side view is provided in Figure 45 from B-100. It can be seen that the pipe runs vertically through the Turbine Building slab from the 592 to 22 above the 5616: elevation at the middle of the 45 degree bend into the discharge tunnel. The vertical drop will be from the 588 elevation to the 5638 elevation. This makes the vertical section 24 4 long as seen in Figure 45. The base of the triangle formed by the slanted section from the Discharge Tunnel wall to the center of the pipe is 108. The vertical drop is 136 this results in a hypotenuse of 14.27 feet forming an overall length of 42.6 feet.

TSD 14-016 Revision 0 Page 63 of 123 Figure 44 - M-15 Top View of Circ Discharge Piping to Discharge Tunnel

TSD 14-016 Revision 0 Page 64 of 123 Figure 45 - Side View of Circ Water Discharge Piping to Discharge Tunnels from B-100 Table 53 - 48 Inch Circulating Water Standpipe Lengths Pipe Section Length Feet Length Inches Vertical from 592' 24.33 292 Slant Base 10.67 Slant Opp 13.5 Hypotenuse 14.27 171.22 Overall Length 38.60 463.22 The 36 diameter standpipes are vertical and embedded from the 588 elevation to the top of the Discharge Tunnel at 5586 (i.e., 5626-3). This results in a length of 296 for each pipe T135 and T136. B-100 shows that the 12 diameter for the Circ Water Discharge lines is an inside diameter and that they are

TSD 14-016 Revision 0 Page 65 of 123 embedded in 5 feet of concrete. It also shows that the 36 access hatch is 1 foot off the floor. Assuming the hatch will not be cut flush to the floor, this results in a 4 foot length.

Each Discharge Tunnel ends at a Valve House near the sheet piling wall as seen on Attachment C. Drawing B-39 shows a 14 diameter Discharge Pipe that travels to the Discharge Diffuser structures in the lake.

Drawing M-2 shows that the distance to the shoreline is bounded at 50 feet. The east west 50 foot dimension is transposed from another part of the drawing as seen in Figure 43.

M-100 shows a 14 diameter pipe has a 0.750 inch wall thickness for the Discharge Pipes.

Figure 46 - Circulating Water Discharge Ice Melting Pipe Dimensions from M-100 The estimated lengths, volumes and interior surface areas of the Circulating Water Discharge Piping are summarized in Error! Reference source not found..

The 48 Service Water Return Line T82 in Unit 1 and T79 in Unit 2 runs through the Turbine Building slab at 55310 elevation as seen on M-103 and M-104 and the excerpt provided as Figure 47. It empties into the Discharge Tunnel.

TSD 14-016 Revision 0 Page 66 of 123 Figure 47 - Unit 1 T82 and Unit 2 T79 48" Service Water Return The side view of the T82 line entering the Unit 1 Discharge Tunnel is shown in Figure 45 which excerpted from drawing B-100. The Unit 1 T82 dimensions are provided on M-103. The distance east from where it enters the Discharge Tunnel is 138+6 or 198. The line then runs north from Column 31 to Column 20 where it joins the Unit 2 line T82. The north runs distance to column 20 is 31-43+25+273+273+219+219 or 1499. The section that Ts off the north line to the floor penetration at G23 is 134+16-5 or 24 4. The vertical rise from the 55310 to the floor at 560 is 62.

The T82 segment lengths are summarized in Table 54.

TSD 14-016 Revision 0 Page 67 of 123 Table 54 - Unit 1 T82 48" Service Water Return Pipe Segment Lengths Section Drawing Feet Unit 1 Disch Tunnel East M-103 19.67 Unit 1 Disch Tunnel North M-103 149.75 Unit 1 Disch Tunnel East M-103 24.33 Unit 1 Vertical to Floor at G23 M-103 6.17 Total 199.92 The T79 Unit 2 pipe segment lengths are shown on drawing M-104. They are the same dimensions with the exception that M-104 has more length on the southward segment to column 20 where it joins T82 than M-103 has at 31-43+25+273+273+219+219 or 1499.

Table 55 - Unit 2 T79 48" Service Water Return Pipe Segment Lengths Section Drawing Feet Unit 2 Disch Tunnel East M-104 19.67 Unit 2 Disch Tunnel South M-104 149.75 Unit 2 Disch Tunnel East M-104 24.33 Unit 2 Vertical to Floor at G16 M-104 6.17 Total 199.92 As noted above, both T79 and T82 run under the floor at the 55310 elevation or 62 below the 560 Turbine Building floor. The piping sections inventory for Circulating Discharge Piping are provided in Attachment P. The Circulating Water Discharge piping lengths, surface areas and volumes are summarized in Table 56.

Table 56 - Circulating Water Discharge Piping without Ice Melting Piping to Forebay Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Circ Water Discharge Pipe 202.40 1074.86 666.09 4.3.

Crib House Penetrations and Embedded Piping The estimated pipe section lengths and for the Circulating Water Intake piping shown in Attachment C are described in Section 4.1. As seen in Figure 48 there are two 10 diameter Fire Protection lines OFP-011-10 that pass through the Crib House wall at 5859 C1 and 5819 C7. All the pipes will be cut flush to the interior and exterior walls making them 4 feet in length.

TSD 14-016 Revision 0 Page 68 of 123 Figure 48 - Crib House Penetrations M-272 and M-105 Sh 2 There is also a 3" Hot Water Supply OHS-020-3, 3" Hot Water Return OHS-024-3", and 3 Filtered Water line OMU-031-3 at the 5816 elevation. At the 581 elevation there is a 2 Station Air and a 3 Control Air OSA-002-3". Each of these lines will also be cut flush with the exception of the Filtered Water line are within 6 inch sleeves. The inventory of Crib House penetrations is provided in Attachment L. The pipes in the sleeves will be removed leaving the opening of the sleeve. The estimated overall surface areas and volumes using the pipe ID or sleeve IDs is provided in Table 57 Table 57 - Summary of Crib House Penetrations at Match Line AA Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Yard Pen 10.97 1.14 2.92 Open Sleeve 4.88 0.19 0.09 Pipe in Pen 6.10 0.95 2.83 Grand Total 10.97 1.14 2.92

TSD 14-016 Revision 0 Page 69 of 123 4.4.

Waste Water Treatment Facility Penetrations and Buried Piping The Waste Water Treatment Facility has eight subsurface penetrations as shown in Figure 49 and Figure 50.

The pipe in the yard and the interior of the building will be cut flush with the walls. As seen in Figure 50 from B-1024 the walls are 1 foot thick, making the remaining penetration 1 foot in length. The calculated surface areas and void space volumes are shown in Attachment K.

Table 58 - Summary of Waste Water Facility Penetration and Piping Lengths, Surface Areas and Void Space Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Yard Pen 2.44 0.89 0.03 Pipe in Pen 2.44 0.89 0.03 Grand Total 2.44 0.89 0.03

TSD 14-016 Revision 0 Page 70 of 123 Figure 49 - Piping Penetrating Waste Water Treatment Facility Below 588' Elevation from B-1005

TSD 14-016 Revision 0 Page 71 of 123 Figure 50 - Top View Approximate Penetration Locations B-1024 4.5.

Buried Piping Inventory The buried piping associated with the end state structures, such as the service water lines that run under the Main Steam Tunnel slabs, the Condensate, Service Water Supply Headers and Primary Water lines exiting the Turbine Building slab near match line A, Circulating Water Discharge Ice Melting lines, etc. have had the determination of their lengths, surface areas, and void space volumes described in the previous sections. The inventory of buried pipe is provided in Attachment K. The calculated pipe lengths, surface areas and void space volume are summarized in Table 59.

Table 59 - Summary of Buried Pipe Lengths, Surface Areas and Void Spaces Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 302.51 894.48 585.08 Buried Pipe 302.51 894.48 585.08 Bld to Yard Pen 1082.95 1047.50 173.29 Buried Pipe 1082.95 1047.50 173.29 Grand Total 1385.46 1941.98 758.37 4.6.

Fuel Handling Building The fuel handling building penetrations are described in the Auxiliary Building and Containment calculation sections. The inventory of piping and penetrations affiliated with the Fuel Handling

TSD 14-016 Revision 0 Page 72 of 123 Building are provided in Attachment M. The lengths, surface areas and void spaces are summarized in Table 60.

Table 60 - Summary of Fuel Handling Building Affiliated Lengths, Surface Areas and Void Spaces Category, End State Sum of Length meters Sum of Int SA m2 Sum of Void Space m3 Bld to Bld Pen 38.56 13.34 1.34 Buried Pipe 33.56 4.31 0.04 Pipe in Sleeve 5.00 9.03 1.30 Bld to Yard Pen 797.07 324.12 20.89 Buried Pipe 797.07 324.12 20.89 Grand Total 835.63 337.46 22.23

5.

CONCLUSION The complete inventory of end state penetrations and piping along with the estimated lengths, surface areas and void spaces is provided in Attachment F. Attachments A through E provide the overall layout and location of these penetrations. Attachments G through P provide the inventory associated with each piping group. The piping group lengths, surface reas and void space volumes are summarized in Table 61.

TSD 14-016 Revision 0 Page 73 of 123 Table 61 - Summary of End State Penetrations and Piping Lengths, Surface Areas, and Volumes Embedded Bld to Bld Pen Bld to Yard Pen Total LTP Pipe Group TSD Location Length m

Surface Area m2 Void Volume m3 Length m

Surface Area m2 Void Volume m3 Length m

Surface Area m2 Void Volume m3 Length m

Surface Area m2 Void Volume m3 U1 CTMT PEN Attachment G 169.20 242.36 32.48 169.20 242.36 32.48 U2 CTMT PEN Attachment G 169.20 242.36 32.48 169.20 242.36 32.48 U1 Incore Embedded Pipe Attachment G 8.15 1.05 0.015 8.15 1.05 0.01 U2 Incore Embedded Pipe Attachment G 8.15 1.05 0.015 8.15 1.05 0.01 U1 MS Drains Embedded Pipe Attachment H 145.93 46.88 1.20 145.93 46.88 1.20 U2 MS Drains Embedded Pipe Attachment H 144.41 46.39 1.19 144.41 46.39 1.19 U1 Tendon Tunnel Embedded Pipe Attachment H 160.02 51.41 1.31 160.02 51.41 1.31 U2 Tendon Tunnel Embedded Pipe Attachment H 160.02 51.41 1.31 160.02 51.41 1.31 Auxiliary Building PEN Attachment I 482.89 585.06 72.34 924.37 363.69 161.87 1407.26 948.75 234.21 Turbine Building PEN Attachment J 291.56 354.61 43.79 235.59 726.53 13.46 527.15 1081.14 57.24 TB Embedded Pipe Attachment J 588.26 302.43 13.13 588.26 302.43 13.13 WWTF PEN Attachment K 2.44 0.89 0.03 2.44 0.89 0.03 Crib House PEN Attachment L 10.97 1.14 2.92 10.97 1.14 2.92 Spent Fuel PEN Attachment M 38.56 13.34 1.34 797.07 324.12 20.89 835.63 337.46 22.23 Buried Pipe Attachment N 302.51 894.48 585.08 1082.95 1047.50 173.29 1385.46 1941.98 758.37 Circ Water Intake Attachment O 384.27 4412.09 4393.19 384.27 4412.09 4393.19 Circ Water Discharge Pipe Attachment P 202.40 1074.86 666.09 202.40 1074.86 666.09

TSD 14-016 Revision 0 Page 74 of 123

6.

REFERENCES

1. TSD 13-005 Unit 1 & 2 Reactor Building Estimated End State Concrete and Liner Volumes and Surface Areas.
2. TSD 13-006 Reactor Building Units 1 and 2 End State Concrete and Liner Initial Characterization Source Terms and Distributions.
3. TSD 14-005, Backfill Material Specifications.
4. Auxiliary Building 542 ft Embedded Floor Drain Pipe Survey Unit 05119A FSS Release Record Nov 10, 2016.
5. TSD 14-015, Buried Pipe Dose Modeling & DCGLs, Revision 1, March 2016.
6. FSS Plan 06105B Turbine Building Imbedded Piping.
7. ComEd Zion Station Historical Site Assessment, Version 1 - August, 1999.
8. 10 CFR 20 Standards for Protection Against Radiation, Subpart ERadiological Criteria for License Termination http://www.nrc.gov/reading-rm/doc-collections/cfr/part020/.
9. 10 CFR 61.55 Waste Classification.
10. TSD 14-019 Radionuclides of Concern for Soil and Basement Fill Model Source Terms.
11. M-5 Zion Station Unit 1 and 2 General Arrangement Plan Ground Floor 592.
12. TSD 14-014, Rev 2. End State Surface Areas, Volumes, and Source Terms of Ancillary Buildings, August 2015.

TSD 14-016 Revision 0 Page 75 of 123

7.

ATTACHMENTS 7.1.

Attachment A - Building Penetrations South 7.2.

Attachment B - Building Penetrations North 7.3.

Attachment C - Building Penetrations East 7.4.

Attachment D - Unit 1 Main Steam Tunnel and Tendon Tunnel Drains 7.5.

Attachment E - Unit 2 Main Steam Tunnel and Tendon Tunnel Drains 7.6.

Attachment F - End State Penetration and Piping Inventory 7.7.

Attachment G - Unit 1 and 2 Containment and Incore Penetration and Piping Inventory 7.8.

Attachment H - Mains Steam Tunnel and Tendon Tunnel Drains Piping Inventory 7.9.

Attachment I - Auxiliary Building Affiliated Penetrations and Piping 7.10.

Attachment J - Turbine Building Affiliated Penetrations, Piping and Turbine Building Drains 7.11.

Attachment K - Waste Water Treatment Facility 7.12.

Attachment L - Crib House Penetrations and Piping 7.13.

Attachment M - Fuel Handling Building Affiliated Penetrations, Piping 7.14.

Attachment N - Buried Pipe Penetrations and Piping Inventory 7.15.

Attachment O - Circulating Water Intake Penetrations and Piping 7.16.

Attachment P - Circulating Water Discharge Piping Inventory

Attachment A Building Penetrations South TSD # 10-XXX Revision 00 Page 76 of 123

Attachment B Building Penetrations North TSD # 10-XXX Revision 00 Page 77 of 123

Attachment C Building Penetrations East TSD # 14-016 Revision 00 Page 78 of 123

Attachment D Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations TSD # 14-016 Revision 00 Page 79 of 123

Attachment D Unit 1 Main Steam Tunnel and Tendon Tunnel Penetrations TSD # 14-016 Revision 00 Page 80 of 123

Attachment E Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations TSD # 14-016 Revision 00 Page 81 of 123

Attachment E Unit 2 Main Steam Tunnel and Tendon Tunnel Penetrations TSD # 14-016 Revision 00 Page 82 of 123

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 83 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 3.00 G

16 586.00 586.00 17.77 9.42 0.91 1.65 0.27 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 3.00 G

16 578.25 578.25 3.16 0.33 0.91 0.29 0.01 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 3.00 G

16 586.00 586.00 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 3.00 G

23 586.00 586.00 17.77 9.42 0.91 1.65 0.27 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 3.00 G

23 588.00 588.00 3.16 0.33 0.91 0.29 0.01 A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3.00 H

10 571.00 571.00 7.87 1.89 0.91 0.73 0.05 A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents &

Drains 4.5 0.237 4.026 3.00 G

13 569.75 569.75 3.16 0.33 0.91 0.29 0.01 A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents &

Drains 4.5 0.237 4.026 3.00 G

13 568.75 568.75 3.16 0.33 0.91 0.29 0.01 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 3.00 G

13 573.25 573.25 2.41 0.20 0.91 0.22 0.01 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 3.00 G

14 572.25 572.25 7.87 1.89 0.91 0.73 0.05 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 3.00 G

17 574.50 574.50 1.62 0.09 0.91 0.15 0.00 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 3.00 G

17 565.50 565.50 2.41 0.20 0.91 0.22 0.01 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 3.00 G

17 573.17 573.17 3.16 0.33 0.91 0.29 0.01 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 3.00 G

17 570.50 570.50 14.77 6.54 0.91 1.37 0.19 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 3.00 G

13 571.00 571.00 4.76 0.72 0.91 0.44 0.02 A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 2.00 H

10 571.00 571.00 6.87 2.14 0.61 0.64 0.06 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 3.00 G

23 586.50 586.50 7.87 1.89 0.91 0.73 0.05 A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3.00 H

30 571.00 571.00 7.87 1.89 0.91 0.73 0.05 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 3.00 G

17 573.42 573.42 2.41 0.20 0.91 0.22 0.01 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 3.00 G

24 576.25 576.25 2.41 0.20 0.91 0.22 0.01 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 3.00 G

24 568.75 568.75 2.41 0.20 0.91 0.22 0.01 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 3.00 G

24 568.75 568.75 3.16 0.33 0.91 0.29 0.01 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 3.00 G

24 573.00 573.00 4.76 0.72 0.91 0.44 0.02 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 3.00 G

24 571.00 571.00 13.25 5.30 0.91 1.23 0.15 A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water Supply Header 36 0.75 34.5 3.00 G

23 575.00 575.00 27.10 21.21 0.91 2.52 0.60 A027 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.50 G

10 554.75 567.50 232.84 57.91 22.71 21.63 1.64 A028 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 77.67 G

10 553.33 567.50 242.75 60.37 23.67 22.55 1.71 A029 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-017-2" Spent Fuel Pool -

Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool -

Demin Water 2.375 0.154 2.067 89.58 R

24 570.58 583.33 48.48 2.09 27.31 4.50 0.06 A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.50 G

30 554.75 567.50 232.84 57.91 22.71 21.63 1.64 A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 77.67 G

30 553.33 567.50 242.75 60.37 23.67 22.55 1.71 A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 2.00 H

30 571.00 571.00 6.87 1.88 0.61 0.64 0.05 A036 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

24 570.00 0.00 415.27 195.73 21.37 38.58 5.54

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 84 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A037 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571.00 Unknown 4.05 0.14 2.93 0.38 0.004 A038 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571.00 Unknown 11.68 0.39 8.44 1.08 0.01 A039 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

24 571.00 Unknown 7.48 0.25 5.41 0.70 0.01 A040 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R

24 569.33 584.00 131.25 11.01 37.96 12.19 0.31 A041 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R

24 569.33 583.00 39.69 1.33 28.70 3.69 0.04 A042 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R

24 570.58 484.00 34.39 1.48 19.37 3.19 0.04 A043 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R

24 570.58 584.00 96.00 8.05 27.76 8.92 0.23 A044 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R

24 570.58 584.00 50.10 2.16 28.22 4.65 0.06 A046 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94.00 R

24 570.58 584.00 39.62 1.33 28.65 3.68 0.04 A047 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R

24 569.33 583.00 67.80 4.33 25.73 6.30 0.12 A048 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86.00 R

24 569.33 583.00 46.54 2.00 26.21 4.32 0.06 A049 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R

24 570.58 584.00 335.99 70.14 39.04 31.21 1.99 A050 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R

24 570.58 584.00 343.42 71.69 39.90 31.91 2.03 A051 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

16 570.00 573.00 415.27 195.73 21.37 38.58 5.54 A052 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571.00 Unknown 4.05 0.14 2.93 0.38 0.004 A053 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571.00 Unknown 11.68 0.39 8.44 1.08 0.01 A054 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

16 571.00 Unknown 7.48 0.25 5.41 0.70 0.01 A055 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R

16 569.33 583.00 61.28 2.64 34.52 5.69 0.07 A056 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111.00 R

16 569.33 583.00 89.16 5.70 33.83 8.28 0.16 A057 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.50 R

16 569.33 583.00 87.95 5.62 33.38 8.17 0.16 A058 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Decon Pad Drain to Chem Drain Tank 2.375 0.154 2.067 89.75 R

16 569.33 583.00 48.57 2.09 27.36 4.51 0.06 A059 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R

16 570.58 584.00 284.84 59.46 33.10 26.46 1.68 A060 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R

16 570.58 584.00 279.16 58.27 32.44 25.93 1.65 A061 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R

16 569.33 583.00 103.01 6.58 39.09 9.57 0.19 A062 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R

16 570.58 584.00 136.67 11.46 39.52 12.70 0.32 A063 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R

16 570.58 583.00 101.74 6.50 38.61 9.45 0.18 A064 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R

16 570.58 584.00 79.94 4.11 37.69 7.43 0.12 A065 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R

16 569.33 584.00 100.13 6.40 38.00 9.30 0.18 A066 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.50 R

16 569.33 583.00 52.48 1.76 37.95 4.88 0.05 C001 M-105 SH 1 & 2, M-271 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Fire Line Below to ForeBay 0

10.75 0.365 10.02 4.00 AA 111.00 581.75 581.75 0.87 2.19 1.22 0.08 0.06 C002 M-106, M-272 OSA-002-3" Station Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Station Air 6

3.5 0.216 3.068 4.00 AA 111.00 581.00 581.00 0.52 0.79 1.22 0.05 0.02 C003 M-106, M-272 0

Control Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Control Air 6

2.375 0.154 2.067 4.00 AA 111.00 581.00 581.00 0.52 0.79 1.22 0.05 0.02

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 85 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 C004 M-106, M-272 OHS-020-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Supply 6

3.5 0.216 3.068 4.00 AA 111.00 581.50 581.50 0.52 0.79 1.22 0.05 0.02 C005 M-106, M-272 OHS-024-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Return 6

2.375 0.154 2.067 4.00 AA 111.00 581.50 581.50 0.52 0.79 1.22 0.05 0.02 C006 M-106, M-272 OMU-031-3" Filtered Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Filtered Water 0

3.5 0.216 3.068 4.00 AA 111.00 581.50 581.50 0.27 0.21 1.22 0.02 0.01 C007 M-106, M-272 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Fire Line Below to ForeBay 0

10.75 0.365 10.02 4.00 AA 111.00 585.75 585.75 0.87 2.19 1.22 0.08 0.06 C026 M-104 & M-105 sh 1, M-102, M-168 OSW-014-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.50 G

19 549.67 549.67 174.92 2044.35 52.27 16.25 57.89 C026c M-104 & M-105 sh 1, M-102, M-168 OSW-014-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Service Water Supply Header Crib Pen 0

48 0.625 46.75 4.00 AA 19.00 579.00 579.00 4.08 47.68 1.22 0.38 1.35 C026a M-105 SH 1 & 2, M-272 OSW-014-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

19 579.00 549.67 38.08 445.03 11.38 3.54 12.60 C029 M-104 & M-105 sh 1, M-102, M-168 OSW-013-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.50 G

21 549.67 549.67 174.92 2044.35 52.27 16.25 57.89 C029c M-104 & M-105 sh 1, M-102, M-168 OSW-013-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Service Water Supply Header Crib Pen 0

48 0.625 46.75 4.00 AA 21.00 579.00 579.00 4.08 47.68 1.22 0.38 1.35 C029a M-105 SH 1 & 2, M-272 OSW-013-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

21 579.00 549.67 38.08 445.03 11.38 3.54 12.60 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.07 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6

0 0

0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.03 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6

0 0

0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.03 P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Boron Injection Tank to Cold Legs 8

3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.05 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P007 M-281, M-661 1-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P008 M-281, M-661 1-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.63 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.63 P017 M-281, M-661 1-RH-015-14" Residual Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.59 P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Component Cooling Water Supply Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.59 P022 M-281, M-661 1-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.59 P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.11

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 86 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.15 P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.11 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.11 P035 B-278, M-7, B-223, M-170, 1SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.80 P036 B-278, M-7, B-223, M-170, 1CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.77 P037 B-278, M-7, B-223, M-170, 1CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.78 P042 M-281, M-661 1-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 6

1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.03 P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 8

3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P049 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.65 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.07 P054 M-281, M-661 1-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Containment Pressure 6

2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.03 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Filtered Vents 8

2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.07 P066 M-281, M-661 1-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pump Seal Water Supply Lines 14 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.15 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P071 M-281, M-661 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.15 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.15 P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.15 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Non-Filtered Vents 8

2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.07 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.07 P086 M-282, M-661 1-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.07 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.07 P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.59

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 87 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P091 M-281, M-661 1-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P094 M-281, M-661 1-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 8

0 0

0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.05 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.43 P105 M-282, M-662 1-SI-011-10" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.24 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P115 M-282, M-662 1-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P118 M-282, M-662 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P123 B-278, M-7, B-223, M-170, 1SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.84 P124 B-278, M-7, B-223, M-170, 1SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.89 P125 B-234 1AD-??-???

Drain Bld Pen Embedded Pipe Class 1 U1 CTMT U1 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.74 0

0 542.50 542.50 11.27 0.53 8.15 1.05 0.01 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.07 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6

0 0

0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.03 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6

0 0

0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.03 P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Boron Injection Tank to Cold Legs 8

3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.05 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P207 M-281, M-661 2-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P208 M-281, M-661 2-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.54 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 88 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.63 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.63 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.63 P217 M-281, M-661 2-RH-015-14" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.59 P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Component Cooling Water Supply Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.59 P222 M-281, M-661 2-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.59 P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.15 P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.11 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.11 P235 B-278, M-7, B-223, M-170, 2SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.80 P236 B-278, M-7, B-223, M-170, 2CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.77 P237 B-278, M-7, B-223, M-170, 2CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.78 P242 M-281, M-661 2-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 6

1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.03 P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 8

3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P249 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.65 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.07 P254 M-281, M-661 2-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Containment Pressure 6

2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.03 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Filtered Vents 8

2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.07 P266 M-281, M-661 2-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pump Seal Water Supply Lines 14 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.15 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.15 P271 M-281, M-661 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.15

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 89 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.24 P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.15 P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.15 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Non-Filtered Vents 8

2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.05 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.07 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.07 P286 M-282, M-661 2-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.07 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.07 P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.11 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.59 P291 M-281, M-661 2-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P294 M-281, M-661 2-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.12 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 8

0 0

0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.05 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.43 P305 M-282, M-662 2-SI-011-10" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.24 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P315 M-282, M-662 2-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P318 M-282, M-662 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.16 P323 B-278, M-7, B-223, M-170, 2SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.84 P324 B-278, M-7, B-223, M-170, 2SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.89 P325 B-234 2AD-??-???

Drain Bld Pen Embedded Pipe Class 1 U2 CTMT U2 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.74 0

0 542.50 542.50 11.27 0.53 8.15 1.05 0.01

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 90 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.16 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.16 T032 M-103 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from Diesel Generator Heat Exchangers 16 0.5 15 183.47 G

31 553.83 567.50 720.48 225.15 55.92 66.93 6.38 T033 M-104 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from to Diesel Generator Heat Exchangers 16 0.5 15 183.75 G

10 553.83 567.50 721.58 225.50 56.01 67.04 6.39 T034a M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Main Stm Blank Sleeve 14 0

14 2.00 H

31 587.75 587.75 7.33 2.14 0.61 0.68 0.06 T034b M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Main Stm Blank Sleeve 14 0

14 2.00 H

10 587.75 587.75 7.33 2.14 0.61 0.68 0.06 T035 M-106, M-107 0

Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 3.00 J

5 583.50 584.50 7.87 1.64 0.91 0.73 0.05 T036 M-106, M-107 0

Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 3.00 J

35 583.50 584.50 7.87 1.64 0.91 0.73 0.05 T068 M-104, M-562 2DO-006-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG Yard Diesel Oil Tank Fill Line length to 588' elevation 4.5 0.237 4.026 4.00 G

5 585.25 593.00 4.22 0.35 1.22 0.39 0.01 T069 M-104, M-562, M-663 2DO-004-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

1.50 G

6 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T070 M-104, M-562, M-663 2DO-001-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

1.50 G

7 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T070a M-104 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG TB Open Sleeve 8

0 0

1.50 G

8 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T071 M-103, M-214, M-244 1DO-010-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

1.50 G

32 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T072 M-103, M-214, M-244 1DO-003-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

1.50 G

33 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T073 M-103, M-214, M-244 1DO-002-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

1.50 G

34 585.17 585.17 3.14 0.52 0.46 0.29 0.01 T074 M-103, M-214 1DO-001-4" Diesel Oil Bld to Yard Pen Buried Pipe Class 3 DG Yard Diesel Oil see buried pipe 4.5 0.237 4.026 52.25 G

35 585.25 593.00 55.07 4.62 15.93 5.12 0.13 T075 M-104, B-68, B-100 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Stand Pipe 48 0.625 46.75 38.60 F

9 588.00 553.00 472.45 460.15 11.77 43.89 13.03 T076 M-103, B-62, B-100 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Stand Pipe 48 0.625 46.75 38.60 F

31 588.00 553.00 472.45 460.15 11.77 43.89 13.03 T077 M-15, M-101, B-100, M-104 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5.00 E

9 562.00 557.00 188.50 565.49 1.52 17.51 16.01 T078 M-15, M-101, B-100, M-104 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5.00 E

9 562.00 557.00 188.50 565.49 1.52 17.51 16.01 T079 B-66, B-68, M-104 0

Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Service Water Return to Discharge Tunnel 48 0.625 46.75 199.92 E

9 553.83 560.00 2446.80 2383.09 60.93 227.32 67.48 T080 M-780, M-101, M-103 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5.00 E

31 562.00 557.00 188.50 565.49 1.52 17.51 16.01 T081 M-780, M-101, M-103 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5.00 E

31 562.00 557.00 188.50 565.49 1.52 17.51 16.01 T082 B-62, B-64, M-103 0

Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Service Water Return to Discharge Tunnel 48 0.625 46.75 199.92 E

33 553.83 560.00 2446.80 2383.09 60.93 227.32 67.48 T083 M-780, M-100, M-101, M-104 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Blind Flange Man Entry to Circ Water Intake 36 0.375 35.25 9.00 D

6 564.00 564.00 83.06 60.99 2.74 7.72 1.73

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 91 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T084 M-780, B-68, B-100, B-68, M-104 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circ Water Discharge Stand Pipe 36 0.375 35.25 29.50 D

9 588.00 558.50 272.24 199.93 8.99 25.29 5.66 T085 M-780, M-100, M-101, M-104 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Blind Flange Man Entry to Circ Water Intake 36 0.375 35.25 9.00 D

13 564.00 564.00 83.06 60.99 2.74 7.72 1.73 T086 M-15, B-62, B-100, B-66 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circ Water Discharge Stand Pipe 36 0.375 35.25 29.50 D

31 588.00 558.50 272.24 199.93 8.99 25.29 5.66 T087 M-15, M-100, M-101, B-64, M-103 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Blind Flange Man Enttry to Circ Water Intake 36 0.375 35.25 9.00 D

27 564.00 564.00 83.06 60.99 2.74 7.72 1.73 T088 M-15, M-100, M-101, B-62, M-103 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Blind Flange Man Enttry to Circ Water Intake 36 0.375 35.25 9.00 D

34 564.00 564.00 83.06 60.99 2.74 7.72 1.73 T091 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 10.75 0.365 10.02 5.00 C

16 585.00 585.00 13.12 2.74 1.52 1.22 0.08 T092 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 12.75 0.406 11.938 5.00 C

16 586.00 586.00 15.63 3.89 1.52 1.45 0.11 T093 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 14 0.438 13.124 5.00 C

16 585.00 585.00 17.18 4.70 1.52 1.60 0.13 T094 M-104 0

Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Fibercast Makeup Demin Waste Discharge 8.625 0.322 7.981 4.00 C

17 586.00 586.00 8.36 1.39 1.22 0.78 0.04 T095 M-104, M-105 0

Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Primary Water Storage Tank 6.625 0.28 6.065 118.33 C

18 556.75 556.75 187.89 23.74 36.07 17.46 0.67 T096 M-103 0

Oil Seperator Bld to Yard Pen Pipe in Pen Class 3 TB Yard Oil Seperator Tank 10.75 0.365 10.02 4.00 C

23 586.00 586.00 10.49 2.19 1.22 0.97 0.06 T097 M-103 0

Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Fibercast Makeup Demin Waste Discharge 8.625 0.322 7.981 4.00 C

23 586.00 586.00 8.36 1.39 1.22 0.78 0.04 T098 M-103 0

Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Waste Discharge (WD) from Lake Discharge Tank to Discharge Tunnel 6.625 0.28 6.065 4.00 C

24 586.00 586.00 6.35 0.80 1.22 0.59 0.02 T099 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 10.75 0.365 10.02 5.00 C

24 585.00 585.00 13.12 2.74 1.52 1.22 0.08 T100 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 12.75 0.406 11.938 5.00 C

24 586.00 586.00 15.63 3.89 1.52 1.45 0.11 T101 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 14 0.438 13.124 5.00 C

24 585.00 585.00 17.18 4.70 1.52 1.60 0.13 T102 M-104, M-105 0

Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Primary Water Supply Header to RCP 6.625 0.28 6.065 78.33 C

17 586.00 586.00 124.38 15.72 23.88 11.56 0.45 T103 M-105 SH 1 & SH 2, M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate to Alternate Feedwater Pumps-Buried Section 20 0.594 18.812 226.05 B

21 586.00 586.00 1020.52 367.34 68.90 94.81 10.40 T104 M-104 0

Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Lake Discharge tank 6.625 0.28 6.065 4.00 C

17 586.00 586.00 6.35 0.80 1.22 0.59 0.02 T105 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate Pump Recirc 4.5 0.337 3.826 221.05 G

22 560.00 586.00 6219.50 14.99 67.38 577.81 0.42 T106 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard To condensate transfer and makeup pumps 12.75 0.406 11.938 20.93 D

22 560.00 583.25 65.41 16.27 6.38 6.08 0.46 T109 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.50 E

34 564.00 564.00 291.38 643.47 3.20 27.07 18.22 T110 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.50 E

34 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T111 M-100, B-61 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 45.63 E

34 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 T111b M-100, B-61 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 22.50 E

34 564.00 564.00 833.50 2457.10 6.86 77.44 69.58 T112 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 124.20 E

34 564.00 564.00 4600.94 13563.19 37.86 427.44 384.07 T113 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 12' to 17' expansion 174 1.5 171 9.00 E

34 558.00 558.00 402.91 1435.36 2.74 37.43 40.64 T114 M-100 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 204 1.5 201 94.67 B

31 558.00 558.00 4981.52 20860.11 28.85 462.80 590.69 T115 M-100, M-272 1CW-001-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 14.25 AA 20 558.00 558.00 499.12 1434.84 4.34 46.37 40.63

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 92 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T116 M-100, M-272 1CW-002-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 19.50 AA 22 558.00 558.00 541.14 1195.02 5.94 50.27 33.84 T117 M-100, M-272 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 14.25 AA 24 558.00 558.00 395.45 873.28 4.34 36.74 24.73 T118 M-100 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 114 1

112 8.25 AA 26 558.00 558.00 241.90 564.44 2.51 22.47 15.98 T119 M-100 1CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 120 1

118 14.00 AA 26 558.00 558.00 432.49 1063.21 4.27 40.18 30.11 T120 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.50 E

26 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T121 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2,5 E

26 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T122 M-100, B-61 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 144 1.25 141.5 45.63 E

6 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 T122b M-100, B-61 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 144 1.25 141.5 83.50 E

6 564.00 564.00 1760.39 5089.54 25.45 163.55 144.12 T123 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.50 E

6 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T123a M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.50 E

6 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T124 M-100, B-61 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E

6 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12 T124b M-100, B-61 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 22.50 E

6 564.00 564.00 1760.39 5089.54 6.86 163.55 144.12 T125 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 12' to 17' expansion 144 1.25 141.5 124.20 E

6 564.00 564.00 4600.94 13563.19 37.86 427.44 384.07 T126 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 12' to 17' expansion 174 1.5 171 9.00 B

8 558.00 558.00 402.91 1435.36 2.74 37.43 40.64 T127 M-100 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 204 1.5 201 94.67 A

12 558.00 558.00 4981.52 20860.11 28.85 462.80 590.69 T128 M-100, M-272 2CW-001-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 14.25 AA 20 558.00 558.00 499.12 1434.84 4.34 46.37 40.63 T129 M-100, M-272 2CW-002-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 19.50 AA 18 558.00 558.00 541.14 1195.02 5.94 50.27 33.84 T130 M-100, M-272 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 14.25 AA 16 558.00 558.00 395.45 873.28 4.34 36.74 24.73 T131 M-100 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 114 1

112 8.25 AA 14 558.00 558.00 241.90 564.44 2.51 22.47 15.98 T132 M-100 2CW-003-108" Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 120 1

118 14.00 AA 14 558.00 558.00 432.49 1063.21 4.27 40.18 30.11 T133 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.50 E

14 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T134 M-100 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.50 E

14 572.00 572.00 291.38 643.47 3.20 27.07 18.22 T135 M-104, B-68, B-100 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Hatch to Discharge Tunnel 36 0.375 35.25 4.00 D

9 562.00 562.00 36.91 27.11 1.22 3.43 0.77 T136 M-103, B-62, B-100 0

Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Hatch to Discharge Tunnel 36 0.375 35.25 4.00 D

31 562.00 562.00 36.91 27.11 1.22 3.43 0.77 T137 M-1, M-2, B-39, M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Lake Unit 2 Circ Water Discharge Pipe to Lake 168 0.75 166.5 50.00 GG 9

568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 T138 M-1, M-2, B-39, M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U1 Disch Tun Lake Unit 1 Circ Water Discharge Pipe to Lake 168 0.75 166.5 50.00 GG 31 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 T139 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Forebay Unit 2 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569.00 569.00 2978.98 8781.78 24.51 276.76 248.67 T140 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Forebay Unit 2 Circ Water Ice Melting Pipe 96 1

94 25.00 GG 31 569.00 569.00 615.23 1204.82 7.62 57.16 34.12 T141 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Disch Tun Forebay Unit 1 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569.00 569.00 2978.98 8781.78 24.51 276.76 248.67 T142 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Disch Tun Forebay Unit 1 Circ Water Ice Melting Pipe 96 1

94 25.00 GG 31 569.00 569.00 615.23 1204.82 7.62 57.16 34.12 T143 M-100, B-61 0

Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E

14 564.00 564.00 1760.39 5089.54 13.91 163.55 144.12

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 93 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T143b M-100, B-61 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 83.50 E

14 564.00 564.00 1760.39 5089.54 25.45 163.55 144.12 T144 M-2, B-49 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50.00 GG 16 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 T145 M-2, B-49 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50.00 GG 20 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 T146 M-2, B-49 0

Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50.00 GG 24 558.00 558.00 2493.64 9896.63 15.24 231.67 280.24 T147 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe West Wall 6

0.28 5.44 200.00 0.00 0

560.00 557.00 284.84 32.28 60.96 26.46 0.91 T148 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe North Wall 6

0.28 5.44 100.00 0.00 0

560.00 557.00 142.42 16.14 30.48 13.23 0.46 T149 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-2 Equip Drain Sump, 6 pipe West Wall 6

0.28 5.44 200.00 0.00 0

560.00 557.00 284.84 32.28 60.96 26.46 0.91 T150 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump, West-most 6 pipe on North Wall 6

0.28 5.44 100.00 0.00 0

560.00 557.00 142.42 16.14 30.48 13.23 0.46 T151 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump East-most 4 pipe on North Wall 4

0.237 3.526 100.00 0.00 0

560.00 557.00 92.31 6.78 30.48 8.58 0.19 T152 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, South-most 4 pipe on West Wall 4

0.237 3.526 150.00 0.00 0

560.00 557.00 138.47 10.17 45.72 12.86 0.29 T153 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, North-most 8 pipe on West Wall 8

0.322 7.356 450.00 0.00 0

560.00 557.00 866.61 132.81 137.16 80.51 3.76 T154 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 8 pipe on North Wall 8

0.322 7.356 450.00 0.00 0

560.00 557.00 866.61 132.81 137.16 80.51 3.76 T155 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 10 pipe on North Wall 10 0.365 9.27 80.00 0.00 0

560.00 557.00 194.15 37.50 24.38 18.04 1.06 T156 M-103, B-454, B-452, B-471, B-473 0

Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, East-most 10 pipe on North Wall 10 0.365 9.27 100.00 0.00 0

560.00 557.00 242.69 46.87 30.48 22.55 1.33 M001 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.34 U

32 569.54 569.00 47.79 4.01 13.82 4.44 0.11 M002 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 40.67 U

34 569.96 567.25 42.86 3.60 12.40 3.98 0.10 M003 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 93.23 R

34 569.54 569.00 98.27 8.24 28.42 9.13 0.23 M004 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 84.11 R

34 569.54 569.00 88.66 7.44 25.64 8.24 0.21 M005 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.25 G

34 569.96 566.17 36.10 3.03 10.44 3.35 0.09 M006 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.72 J

34 569.54 569.00 12.35 1.04 3.57 1.15 0.03 M007 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 67.33 J

33 569.96 566.08 70.97 5.95 20.52 6.59 0.17 M009 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.96 J

32 569.54 569.00 9.45 0.79 2.73 0.88 0.02 M010 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.42 J

31 569.96 568.79 47.87 4.02 13.84 4.45 0.11 M011 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 16.96 J

30 569.54 569.00 17.87 1.50 5.17 1.66 0.04 M012 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.79 J

30 569.54 569.00 32.45 2.72 9.39 3.02 0.08 M013 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M014 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M015 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 L

31 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M016 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 L

28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M017 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M018 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 94 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 M019 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M020 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M021 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M022 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M023 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M024 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Embedded Center Pipe 4.5 0.237 4.026 359.97 R

28 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M025 B466, B467 0

U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 R

28 547.54 547.50 10.28 0.86 2.97 0.95 0.02 M201 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.49 U

8 569.54 568.85 47.95 4.02 13.87 4.45 0.11 M202 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 39.50 U

6 569.96 568.42 41.63 3.49 12.04 3.87 0.10 M203 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 92.86 R

6 569.54 568.85 97.87 8.21 28.30 9.09 0.23 M204 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 82.86 R

6 569.54 568.83 87.33 7.32 25.25 8.11 0.21 M205 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.04 G

6 569.96 566.38 35.88 3.01 10.38 3.33 0.09 M206 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.95 J

6 569.54 568.88 12.59 1.06 3.64 1.17 0.03 M207 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 66.81 J

7 569.96 566.10 70.42 5.91 20.36 6.54 0.17 M209 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.95 J

8 569.54 568.88 9.43 0.79 2.73 0.88 0.02 M210 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 43.47 J

9 569.96 568.80 45.81 3.84 13.25 4.26 0.11 M211 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 17.02 J

10 569.54 568.94 17.94 1.50 5.19 1.67 0.04 M212 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.85 J

10 569.54 568.94 32.52 2.73 9.40 3.02 0.08 M213 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M214 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M215 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 L

9 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M216 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 L

6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M217 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 R

6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M218 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M219 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M220 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M221 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M222 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M223 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.002 M224 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Embedded Center Pipe 4.5 0.237 4.026 359.97 R

6 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M225 B481, B484 0

U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 R

6 547.54 547.50 10.28 0.86 2.97 0.95 0.02 W001 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Force Main from Turbine Fire Sump 8.625 0.322 7.981 1.00 D

2 586.67 586.67 2.09 0.35 0.30 0.19 0.01

Attachment F Penetration Pipe Section Estimated Lengths, Void Space and Interior Surface Areas TSD # 14-016 Revision 00 Page 95 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 W002 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Heater bay roof drain lines 6.625 0.28 6.065 1.00 D

2 585.20 585.20 1.59 0.20 0.30 0.15 0.01 W003 B-1003, B-1005 Sludge Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sludge Line from Outdoor Drying Beds 3.5 0.216 3.068 1.00 A

6 587.00 587.00 0.80 0.05 0.30 0.07 0.001 W004 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTH WWTF Sludge drying bed filtrate 6.625 0.28 6.065 1.00 A

4 588.00 588.00 1.59 0.20 0.30 0.15 0.01 W005 B-1003, B-1005 Water Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Water Line from Yard 2.375 0.154 2.067 1.00 A

3 588.00 588.00 0.54 0.02 0.30 0.05 0.001 W006 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Cement Wrapped Ductile Pipe 8.625 0.322 7.981 1.00 A

2 586.75 586.75 2.09 0.35 0.30 0.19 0.01 W007 B-1003, B-1005 Sanitary Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sanitary Line 1.9 0.145 1.61 1.00 A

2 587.00 587.00 0.42 0.01 0.30 0.04 0.0004 W008 B-1003, B-1005 Service Air Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Service Air Line 1.9 0.145 1.61 1.00 A

2 586.75 586.75 0.42 0.01 0.30 0.04 0.0004

Attachment G Unit 1 and Unit 2 Containment Penetrations and Piping List TSD # 14-016 Revision 00 Page 96 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.5 577.5 12.65 2.64 1.47 1.18 0.075 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6

0 0

0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 6

0 0

0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Boron Injection Tank to Cold Legs 8

3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P007 M-281, M-661 1-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P008 M-281, M-661 1-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 P017 M-281, M-661 1-RH-015-14" Residual Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Component Cooling Water Supply Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P022 M-281, M-661 1-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P035 B-278, M-7, B-223, M-170, 1SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 P036 B-278, M-7, B-223, M-170, 1CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 P037 B-278, M-7, B-223, M-170, 1CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 P042 M-281, M-661 1-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 6

1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 8

3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P049 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.649 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 P054 M-281, M-661 1-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Containment Pressure 6

2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Filtered Vents 8

2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P066 M-281, M-661 1-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pump Seal Water Supply Lines 14 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146

Attachment G Unit 1 and Unit 2 Containment Penetrations and Piping List TSD # 14-016 Revision 00 Page 97 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P071 M-281, M-661 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 18 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Non-Filtered Vents 8

2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P086 M-282, M-661 1-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 28 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P091 M-281, M-661 1-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P094 M-281, M-661 1-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 8

0 0

0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 P105 M-282, M-662 1-SI-011-10" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P115 M-282, M-662 1-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P118 M-282, M-662 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P123 B-278, M-7, B-223, M-170, 1SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 P124 B-278, M-7, B-223, M-170, 1SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158

Attachment G Unit 1 and Unit 2 Containment Penetrations and Piping List TSD # 14-016 Revision 00 Page 98 of 123 Peno.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Fire Protection 10 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.075 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6

0 0

0 4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 6

0 0

0 4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Boron Injection Tank to Cold Legs 8

3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 34 1.15625 31.6875 4.00 213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P207 M-281, M-661 2-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P208 M-281, M-661 2-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 50 35.5 1.1875 33.125 4.00 333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 32 16 1.218 13.564 4.00 333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 P217 M-281, M-661 2-RH-015-14" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 28 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1A Discharge 18 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Component Cooling Water Supply Header to RCPs 12 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1B Discharge 18 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P222 M-281, M-661 2-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 28 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 14 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 12 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Demin Water 12 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P235 B-278, M-7, B-223, M-170, 2SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 P236 B-278, M-7, B-223, M-170, 2CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 P237 B-278, M-7, B-223, M-170, 2CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 24 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 P242 M-281, M-661 2-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 6

1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 8

3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P249 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT SFB Fuel Transfer Tube 24 24 0.688 22.624 8.21 90 270 578.54 578.54 48.62 22.92 2.50 4.52 0.649 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 P254 M-281, M-661 2-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Containment Pressure 6

2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Filtered Vents 8

2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P266 M-281, M-661 2-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pump Seal Water Supply Lines 14 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1C 14 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146

Attachment G Unit 1 and Unit 2 Containment Penetrations and Piping List TSD # 14-016 Revision 00 Page 99 of 123 Peno.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1A 14 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 14 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P271 M-281, M-661 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Steam Generator Blowdown 14 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 18 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1D 14 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Accumulator Tank Sample 14 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Non-Filtered Vents 8

2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P286 M-282, M-661 2-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 10 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 10 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Supply 12 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Return 12 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 28 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P291 M-281, M-661 2-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.375 0.218 1.939 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P294 M-281, M-661 2-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 16 2.875 0.276 2.323 4.00 213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 14 2.375 0.218 1.939 4.00 213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1D 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1B 14 2.375 0.218 1.939 4.00 333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 8

0 0

0 4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux SIM to Aux F.S. Pumps 24 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 P305 M-282, M-662 2-SI-011-10" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 18 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 16 0.675 0.065 0.545 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P315 M-282, M-662 2-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.375 0.218 1.939 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P318 M-282, M-662 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 16 2.875 0.276 2.323 4.00 333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P323 B-278, M-7, B-223, M-170, 2SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.00 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 P324 B-278, M-7, B-223, M-170, 2SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 24 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 16 6.625 0.432 5.761 4.00 333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158

Attachment G Unit 1 and Unit 2 Containment Penetrations and Piping List TSD # 14-016 Revision 00 Page 100 of 123 Incore Sump Inventory Penetration No.

Drawings System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P125 B-234 Drain Bld Pen Embedded Pipe Class 1 U1 CTMT U1 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.73908 542.5 542.5 11.27 0.53 8.15 1.05 0.015 P325 B-234 Drain Bld Pen Embedded Pipe Class 1 U1 CTMT U1 CTMT Incore Sump Pipe 1.9 1.9 0.145 1.61 26.73908 542.5 542.5 11.27 0.53 8.15 1.05 0.015

Attachment H Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List TSD # 14-016 Revision 00 Page 101 of 123 Main Steam Tunnel Drains Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Void Space Volume in3 Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 M001 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.34 6925.92 U

32 569.54 569.00 47.79 4.01 13.82 4.44 0.113 M002 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 40.67 6212.37 U

34 569.96 567.25 42.86 3.60 12.40 3.98 0.102 M003 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 93.23 14242.42 R

34 569.54 569.00 98.27 8.24 28.42 9.13 0.233 M004 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 84.11 12849.55 R

34 569.54 569.00 88.66 7.44 25.64 8.24 0.211 M005 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.25 5232.14 G

34 569.96 566.17 36.10 3.03 10.44 3.35 0.086 M006 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.72 1789.66 J

34 569.54 569.00 12.35 1.04 3.57 1.15 0.029 M007 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 67.33 10286.05 J

33 569.96 566.08 70.97 5.95 20.52 6.59 0.169 M009 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.96 1369.41 J

32 569.54 569.00 9.45 0.79 2.73 0.88 0.022 M010 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.42 6938.07 J

31 569.96 568.79 47.87 4.02 13.84 4.45 0.114 M011 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 16.96 2590.61 J

30 569.54 569.00 17.87 1.50 5.17 1.66 0.042 M012 B466, B467 U1 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 1 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.79 4703.83 J

30 569.54 569.00 32.45 2.72 9.39 3.02 0.077 M201 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 45.49 6949.51 U

8 569.54 568.85 47.95 4.02 13.87 4.45 0.114 M202 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 39.50 6034.15 U

6 569.96 568.42 41.63 3.49 12.04 3.87 0.099 M203 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 92.86 14185.06 R

6 569.54 568.85 97.87 8.21 28.30 9.09 0.232 M204 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 82.86 12657.42 R

6 569.54 568.83 87.33 7.32 25.25 8.11 0.207 M205 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 34.04 5200.31 G

6 569.96 566.38 35.88 3.01 10.38 3.33 0.085 M206 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 11.95 1824.76 J

6 569.54 568.88 12.59 1.06 3.64 1.17 0.030 M207 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 66.81 10206.49 J

7 569.96 566.10 70.42 5.91 20.36 6.54 0.167 M209 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 8.95 1366.75 J

8 569.54 568.88 9.43 0.79 2.73 0.88 0.022 M210 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 43.47 6639.88 J

9 569.96 568.80 45.81 3.84 13.25 4.26 0.109 M211 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 17.02 2600.16 J

10 569.54 568.94 17.94 1.50 5.19 1.67 0.043 M212 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 Main Stm TT Unit 2 Main Steam Tunnel Aerated Drain 4.5 0.237 4.026 30.85 4713.38 J

10 569.54 568.94 32.52 2.73 9.40 3.02 0.077 Buttress Pit and Tendon Tunnel Drains Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Void Space Volume in3 Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 M013 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M014 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

33 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M015 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L

31 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M016 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L

28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M017 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

28 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M018 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M019 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M020 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M021 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M022 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00

Attachment H Unit 1 and Unit 2 Main Steam Tunnel, Buttress Pit and Tendon Tunnel Drain Penetrations and Piping List TSD # 14-016 Revision 00 Page 102 of 123 Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Void Space Volume in3 Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 M023 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

28 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M024 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Tendon Tunnel Embedded Center Pipe 4.5 0.237 4.026 359.97 54990.79 R

28 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M025 B466, B467 U2 Aerated Drain U1 Bld Pen Embedded Pipe Class 3 TT TT Unit 1 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 1489.44 R

28 547.54 547.50 10.28 0.86 2.97 0.95 0.02 M213 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M214 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

7 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M215 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L

9 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M216 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 L

6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M217 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Buttress Pit to Tunnel Sump 4.5 0.237 4.026 30.30 4629.42 R

6 564.18 547.75 31.94 2.68 9.24 2.97 0.08 M218 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M219 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M220 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M221 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M222 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M223 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Floor Drain 4.5 0.237 4.026 0.63 95.48 R

6 548.54 547.92 0.66 0.06 0.19 0.06 0.00 M224 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Tendon Tunnel Embedded Center Pipe 4.5 0.237 4.026 359.97 54990.79 R

6 547.92 547.92 379.41 31.82 109.72 35.25 0.90 M225 B481, B484 U2 Aerated Drain U2 Bld Pen Embedded Pipe Class 3 TT TT Unit 2 Clean Out In Front of Sump 4.5 0.237 4.026 9.75 1489.44 R

6 547.54 547.50 10.28 0.86 2.97 0.95 0.02

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 103 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 3

G 16 586 586 17.77 9.42 0.91 1.65 0.267 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 3

G 16 578.25 578.25 3.16 0.33 0.91 0.29 0.009 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 3

G 16 586 586 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 3

G 23 586 586 17.77 9.42 0.91 1.65 0.267 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 3

G 23 588 588 3.16 0.33 0.91 0.29 0.009 A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3

H 10 571 571 7.87 1.89 0.91 0.73 0.054 A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 3

G 13 569.75 569.75 3.16 0.33 0.91 0.29 0.009 A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 3

G 13 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 3

G 13 573.25 573.25 2.41 0.20 0.91 0.22 0.006 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 3

G 14 572.25 572.25 7.87 1.89 0.91 0.73 0.054 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 3

G 17 574.5 574.5 1.62 0.09 0.91 0.15 0.003 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 3

G 17 565.5 565.5 2.41 0.20 0.91 0.22 0.006 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 3

G 17 573.17 573.17 3.16 0.33 0.91 0.29 0.009 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 3

G 17 570.5 570.5 14.77 6.54 0.91 1.37 0.185 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 3

G 13 571 571 4.76 0.72 0.91 0.44 0.020 A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 2

H 10 571 571 6.87 2.14 0.61 0.64 0.061 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 3

G 23 586.5 586.5 7.87 1.89 0.91 0.73 0.054 A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 3

H 30 571 571 7.87 1.89 0.91 0.73 0.054 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 3

G 17 573.42 573.42 2.41 0.20 0.91 0.22 0.006 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 3

G 24 576.25 576.25 2.41 0.20 0.91 0.22 0.006 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 3

G 24 568.75 568.75 2.41 0.20 0.91 0.22 0.006 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 3

G 24 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 3

G 24 573 573 4.76 0.72 0.91 0.44 0.020 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 3

G 24 571 571 13.25 5.30 0.91 1.23 0.150 A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water Supply Header 36 0.75 34.5 3

G 23 575 575 27.10 21.21 0.91 2.52 0.600 A027 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.50 G

10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A028 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 77.67 G

10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A029 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-017-2" Spent Fuel Pool -

Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool - Demin Water 2.375 0.154 2.067 89.58 R

24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.50 G

30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 77.67 G

30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 2.00 H

30 571 571 6.87 1.88 0.61 0.64 0.053 A036 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

24 570 0

415.27 195.73 21.37 38.58 5.543 A037 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 4.05 0.14 2.93 0.38 0.004 A038 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 11.68 0.39 8.44 1.08 0.011 A039 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

24 571 Unknown 7.48 0.25 5.41 0.70 0.007

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 104 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A040 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R

24 569.33 584 131.25 11.01 37.96 12.19 0.312 A041 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R

24 569.33 583 39.69 1.33 28.70 3.69 0.038 A042 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R

24 570.58 484 34.39 1.48 19.37 3.19 0.042 A043 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R

24 570.58 584 96.00 8.05 27.76 8.92 0.228 A044 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R

24 570.58 584 50.10 2.16 28.22 4.65 0.061 A046 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94.00 R

24 570.58 584 39.62 1.33 28.65 3.68 0.038 A047 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R

24 569.33 583 67.80 4.33 25.73 6.30 0.123 A048 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86.00 R

24 569.33 583 46.54 2.00 26.21 4.32 0.057 A049 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R

24 570.58 584 335.99 70.14 39.04 31.21 1.986 A050 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R

24 570.58 584 343.42 71.69 39.90 31.91 2.030 A051 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

16 570 573 415.27 195.73 21.37 38.58 5.543 A052 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 4.05 0.14 2.93 0.38 0.004 A053 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 11.68 0.39 8.44 1.08 0.011 A054 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

16 571 Unknown 7.48 0.25 5.41 0.70 0.007 A055 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R

16 569.33 583 61.28 2.64 34.52 5.69 0.075 A056 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111.00 R

16 569.33 583 89.16 5.70 33.83 8.28 0.161 A057 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.50 R

16 569.33 583 87.95 5.62 33.38 8.17 0.159 A058 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Decon Pad Drain to Chem Drain Tank 2.375 0.154 2.067 89.75 R

16 569.33 583 48.57 2.09 27.36 4.51 0.059 A059 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R

16 570.58 584 284.84 59.46 33.10 26.46 1.684 A060 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R

16 570.58 584 279.16 58.27 32.44 25.93 1.650 A061 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R

16 569.33 583 103.01 6.58 39.09 9.57 0.186 A062 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R

16 570.58 584 136.67 11.46 39.52 12.70 0.325 A063 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R

16 570.58 583 101.74 6.50 38.61 9.45 0.184 A064 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R

16 570.58 584 79.94 4.11 37.69 7.43 0.116 A065 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R

16 569.33 584 100.13 6.40 38.00 9.30 0.181 A066 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.50 R

16 569.33 583 52.48 1.76 37.95 4.88 0.050 C026 M-104 & M-105 sh 1, M-102, M-168 OSW-014-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.50 G

19 549.67 549.67 174.92 2044.35 52.27 16.25 57.889 C026a M-105 SH 1 & 2, M-272 OSW-014-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

19 579 549.67 38.08 445.03 11.38 3.54 12.602 C029 M-104 & M-105 sh 1, M-102, M-168 OSW-013-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.50 G

21 549.67 549.67 174.92 2044.35 52.27 16.25 57.889 C029a M-105 SH 1 & 2, M-272 OSW-013-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

21 579 549.67 38.08 445.03 11.38 3.54 12.602 P001 M-281, M-661 1-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Fire Protection 4.5 0.237 4.026 4.83 107 253 577.5 577.5 12.65 2.64 1.47 1.18 0.075 P002 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 105 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P003 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 98-15 263-45 577.5 577.5 7.59 0.95 1.47 0.71 0.027 P004 M-281, M-661 1-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Boron Injection Tank to Cold Legs 3.5 0.438 2.624 4.83 94 266 577.5 577.5 10.12 1.69 1.47 0.94 0.048 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 34 1.15625 31.6875 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 34 1.15625 31.6875 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P007 M-281, M-661 1-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 35.5 1.1875 33.125 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P008 M-281, M-661 1-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 35.5 1.1875 33.125 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 4

333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 4

333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 P017 M-281, M-661 1-RH-015-14" Residual Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P018 M-281, M-661 1-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1A Discharge 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P019 M-281, M-661 1-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Component Cooling Water Supply Header to RCPs 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P020 M-281, M-661 1-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Cavity Fill Pump 1B Discharge 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P021 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P022 M-281, M-661 1-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 P023 M-281, M-661 1-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P024 M-281, M-661 1-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P033 M-281, M-661 1-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pumps to Comp Cooling Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P034 M-281, M-661 1-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U1 CTMT Aux Demin Water 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P035 B-278, M-7, B-223, M-170, 1SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 P036 B-278, M-7, B-223, M-170, 1CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 P037 B-278, M-7, B-223, M-170, 1CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 P042 M-281, M-661 1-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P043 M-281, M-661 1-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P050 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 P054 M-281, M-661 1-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Containment Pressure 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027 P056 M-281, M-661 1-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Filtered Vents 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P064 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P066 M-281, M-661 1-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux RC Pump Seal Water Supply Lines 14 0.437 13.126 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P067 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P068 M-281, M-661 1-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1C 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 106 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P069 M-281, M-661 1-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1A 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P070 M-281, M-661 1-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P071 M-281, M-661 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Steam Generator Blowdown 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P073 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P074 M-281, M-661 1-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Aux Feedwater to Steam Gen 1D 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P076 M-282, M-662 1-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Accumulator Tank Sample 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P081 M-281, M-661 1-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Non-Filtered Vents 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P084 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P085 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P086 M-282, M-661 1-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P087 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P088 M-281, M-661 1-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Supply 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P089 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Heating System Hot Water Return 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P090 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P091 M-281, M-661 1-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P094 M-281, M-661 1-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P103 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U1 CTMT Aux Spare 0

0 0

4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P104 M-282, M-662 1-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux SIM to Aux F.S. Pumps 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 P105 M-282, M-662 1-SI-011-10" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U1 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P115 M-282, M-662 1-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P118 M-282, M-662 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P123 B-278, M-7, B-223, M-170, 1SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 107 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P124 B-278, M-7, B-223, M-170, 1SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P201 M-281, M-661 2-FP-037-4" Fire Protection Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Fire Protection 4.5 0.237 4.026 4.83 107 253 577.50 577.50 12.65 2.64 1.47 1.18 0.075 P202 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 98-30 261-30 588.83 588.83 7.59 0.95 1.47 0.71 0.027 P203 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 98-15 263-45 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P204 M-281, M-661 2-S1-090-3" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Boron Injection Tank to Cold Legs 3.5 0.438 2.624 4.83 94 266 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 34 1.15625 31.6875 4

213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 34 1.15625 31.6875 4

213 147 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P207 M-281, M-661 2-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 35.5 1.1875 33.125 4

333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P208 M-281, M-661 2-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 35.5 1.1875 33.125 4

333 27 579.50 579.50 52.36 54.54 1.22 4.86 1.544 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 4

333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 4

333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 P217 M-281, M-661 2-RH-015-14" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Reactor Coolant No. 1 Loop to Residual Heat Removal Pumps 14 0.438 13.124 4.83 107 253 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P218 M-281, M-661 2-CF-004-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1A Discharge 10.75 0.365 10.02 4.83 102-45 257-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P219 M-281, M-661 2-CC-091-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Component Cooling Water Supply Header to RCPs 6.625 0.28 6.065 4.83 107 253 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P220 M-281, M-661 2-CF-003-10" Cavity Fill Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Cavity Fill Pump 1B Discharge 10.75 0.365 10.02 4.83 100-45 259-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P221 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 98-30 261-30 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P222 M-281, M-661 2-RH-006-12" Residula Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Cold Legs 12.75 0.406 11.938 4.83 98-30 261-30 580.08 580.08 35.43 20.67 1.47 3.29 0.585 P223 M-281, M-661 2-CC-106-6" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 6.625 0.28 6.065 4.83 100-45 259-15 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P224 M-281, M-661 2-SI-104-4" Safety Injection Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Safety Inj Pumps to RC Loop Hot Leg 4.5 0.438 3.624 4.83 107 253 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P233 M-281, M-661 2-CC-104-3" Component Cooling Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pumps to Comp Cooling Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P234 M-281, M-661 2-DW-006-2" Demin Water Bld to Bld Pen Open Sleeve Class 3 U2 CTMT Aux Demin Water 2.375 0.154 2.067 4.83 96-15' 263-45 588.83 588.83 15.18 3.80 1.47 1.41 0.107 P235 B-278, M-7, B-223, M-170, 2SI-008-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 51.17 135 225 561.25 561.25 251.99 98.76 15.60 23.41 2.797 P236 B-278, M-7, B-223, M-170, 2CF-002-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.75 135 225 561.25 561.25 249.94 97.96 15.47 23.22 2.774 P237 B-278, M-7, B-223, M-170, 2CF-001-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Cavity Flood Sump Suction 20 0.594 18.812 50.83 135 225 561.25 561.25 250.35 98.12 15.49 23.26 2.778 P242 M-281, M-661 2-WO-95-1 1/2" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux CTMT Sump Pump Dischage to Aux Bld Flr Drain Analysis Tank 1.9 0.145 1.61 4.83 104-45 255-15 577.50 577.50 7.59 0.95 1.47 0.71 0.027 P243 M-281, M-661 2-DT-036-3" Rad Discharge Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux RC Drain Pump Discharge to Hold-Up Tank 3.5 0.216 3.068 4.83 107 253 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P250 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 96-15' 263-45 580.08 580.08 12.65 2.64 1.47 1.18 0.075 P254 M-281, M-661 2-CS-063-2" Containment Pressure Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Containment Pressure 2.375 0.154 2.067 4.83 109-15' 250-45 586.83 586.83 7.59 0.95 1.47 0.71 0.027

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 108 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P256 M-281, M-661 2-VF-132-2" Filtered Vents Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Filtered Vents 2.375 0.154 2.067 4.83 100-45' 250-15 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P264 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 94 266 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P266 M-281, M-661 2-VC-033,043, 052E, 085-2" Seal Water Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux RC Pump Seal Water Supply Lines 2.375 0.344 1.687 4.83 102-45' 257-15 580.08 580.08 17.72 5.17 1.47 1.65 0.146 P267 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 108-15' 249-45 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P268 M-281, M-661 2-FW-018-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1C 3.5 0.438 2.624 4.83 100-45' 259-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P269 M-281, M-661 2-FW-015-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1A 3.5 0.438 2.624 4.83 109-15' 250-45 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P270 M-281, M-661 2-DT-032-3" Cavity Drain Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Refueling Cavity Drain to Purification Pump Suction 3.5 0.216 3.068 4.83 102-45' 257-15 577.50 577.50 17.72 5.17 1.47 1.65 0.146 P271 M-281, M-661 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Steam Generator Blowdown 2.875 0.276 2.323 4.83 104-45' 255-15 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P273 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 104-45' 255-15 584.25 584.25 22.78 8.54 1.47 2.12 0.242 P274 M-281, M-661 2-FW-012-3" Feedwater Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Aux Feedwater to Steam Gen 1D 3.5 0.438 2.624 4.83 104-45' 255-15 586.83 586.83 17.72 5.17 1.47 1.65 0.146 P276 M-282, M-662 2-SS-026-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Accumulator Tank Sample 0.675 0.065 0.545 4.83 109-15' 250-45 588.83 588.83 17.72 5.17 1.47 1.65 0.146 P281 M-281, M-661 2-VN-008-2" Vent Non-filtered Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Non-Filtered Vents 2.375 0.154 2.067 4.83 109-15' 250-45 580.08 580.08 10.12 1.69 1.47 0.94 0.048 P284 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 94 266 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P285 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 100-45' 259-45 588.83 588.83 12.65 2.64 1.47 1.18 0.075 P286 M-282, M-661 2-SS-001,2,3-3/8" Sample Line Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Press Stem, Press Liq, RC Hot Leg Samples 0.675 0.065 0.545 4.83 102-45' 257-15 586.83 586.83 12.65 2.64 1.47 1.18 0.075 P287 M-281, M-661 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 96-15' 263-45 584.25 584.25 12.65 2.64 1.47 1.18 0.075 P288 M-281, M-661 2-HS-030-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Supply 2.375 0.218 1.939 4.83 98-30' 261-30 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P289 M-281, M-661 0-HS-053-2" Heating Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Heating System Hot Water Return 2.375 0.218 1.939 4.83 96-15' 263-45 586.83 586.83 15.18 3.80 1.47 1.41 0.107 P290 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 94 266 584.25 584.25 35.43 20.67 1.47 3.29 0.585 P291 M-281, M-661 2-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P294 M-281, M-661 2-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P303 M-282, M-662 Spare N/A Bld to Bld Pen Open Sleeve Class 2 U2 CTMT Aux Spare 0

0 0

4.83 98-30' 261-30 577.50 577.50 10.12 1.69 1.47 0.94 0.048 P304 M-282, M-662 2-MS-018-6" Reactor Coolant Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux SIM to Aux F.S. Pumps 6.625 0.432 5.761 4.83 94 266 580.08 580.08 30.37 15.18 1.47 2.82 0.430 P305 M-282, M-662 2-SI-011-10" Residual Heat Removal Bld to Bld Pen Open Sleeve Class 1 U2 CTMT Aux Residual Heat Exchanger to RC Loop Hot Legs 10.75 1.125 8.5 4.83 104-45 255-15 580.08 580.08 22.78 8.54 1.47 2.12 0.242 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158

Attachment I Auxiliary Building Affiliated Penetrations and Piping List TSD # 14-016 Revision 00 Page 109 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P315 M-282, M-662 2-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P318 M-282, M-662 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P323 B-278, M-7, B-223, M-170, 2SI-007-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52 135 225 561.25 561.25 256.10 100.37 15.85 23.79 2.842 P324 B-278, M-7, B-223, M-170, 2SI-009-20" Drain Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT Aux Recirculating Sump Suction 20 0.594 18.812 52.83 135 225 561.25 561.25 260.20 101.98 16.10 24.17 2.888 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158

Attachment J Turbine Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 110 of 123 Turbine Building Affiliated Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A001 M-162, M-172, M-185 OSW-014-24" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 24 0.688 22.624 36 3

G 16 586 586 17.77 9.42 0.91 1.65 0.267 A002 M-162, M-172, M-185 2FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 Aux TB Feedwater 4.5 0.237 4.026 36 3

G 16 578.25 578.25 3.16 0.33 0.91 0.29 0.009 A003 M-162, M-172, M-185 OWS-011-2" Secondary Sample Bld to Bld Pen Open Sleeve Class 2 Aux TB Secondary Sample 2.375 0.154 2.067 36 3

G 16 586 586 1.62 0.09 0.91 0.15 0.003 A004 M-182, M-163 OSW-013-24" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 24 0.688 22.624 36 3

G 23 586 586 17.77 9.42 0.91 1.65 0.267 A005 M-182, M-163 1FW-027-4" Feedwater Bld to Bld Pen Open Sleeve Class 2 TB Aux Feedwater 4.5 0.237 4.026 36 3

G 23 588 588 3.16 0.33 0.91 0.29 0.009 A006 M-165, M-187 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 36 3

H 10 571 571 7.87 1.89 0.91 0.73 0.054 A007 M-165, M-171, M-185 1VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 36 3

G 13 569.75 569.75 3.16 0.33 0.91 0.29 0.009 A008 M-165, M-171, M-185 2VN-001-4" Vents and Drains Bld to Bld Pen Open Sleeve Class 2 TB Aux Aux Bld Vents & Drains 4.5 0.237 4.026 36 3

G 13 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A009 M-165, M-171, M-185 OWD-031-3 Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 3.5 0.216 3.068 36 3

G 13 573.25 573.25 2.41 0.20 0.91 0.22 0.006 A010 M-165, M-171, M-185 OSW-056-10" Service Water Bld to Bld Pen Open Sleeve Class 3 Aux TB Service Water 10.75 0.365 10.02 36 3

G 14 572.25 572.25 7.87 1.89 0.91 0.73 0.054 A011 M-162, M-172, M-185 OWD-039-2" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 2.375 0.154 2.067 36 3

G 17 574.5 574.5 1.62 0.09 0.91 0.15 0.003 A012 M-165, M-168 OCA-007-3" Chemical Addition Bld to Bld Pen Open Sleeve Class 3 TB Aux Chemical Feed 3.5 0.216 3.068 36 3

G 17 565.5 565.5 2.41 0.20 0.91 0.22 0.006 A013 M-165, M-174 OPW-020-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 4.5 0.237 4.026 36 3

G 17 573.17 573.17 3.16 0.33 0.91 0.29 0.009 A014 M-165, M-174 2SW-002-20" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water 20 0.594 18.812 36 3

G 17 570.5 570.5 14.77 6.54 0.91 1.37 0.185 A015 M-165, M-171, M-185 OWD-016-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 Aux TB Waste Disposal 6.625 0.28 6.065 36 3

G 13 571 571 4.76 0.72 0.91 0.44 0.020 A016 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 24 2

H 10 571 571 6.87 2.14 0.61 0.64 0.061 A017 M-182, M-163 OFP-003-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 TB Aux Fire Protection 10.75 0.365 10.02 36 3

G 23 586.5 586.5 7.87 1.89 0.91 0.73 0.054 A018 M-166, M-188 OFP-012-10" Fire Protection Bld to Bld Pen Open Sleeve Class 3 Main Stm Aux Fire Protection 10.75 0.365 10.02 36 3

H 30 571 571 7.87 1.89 0.91 0.73 0.054 A019 M-165, M-174 OPW-042-3" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Primary Water 3.5 0.216 3.068 36 3

G 17 573.42 573.42 2.41 0.20 0.91 0.22 0.006 A020 M-182, M-166 OVC-071-3" Vacuum Control Bld to Bld Pen Open Sleeve Class 3 TB Aux Vacuum Control 3.5 0.216 3.068 36 3

G 24 576.25 576.25 2.41 0.20 0.91 0.22 0.006 A021 M-182,M-166 ODW-003-3" Demin Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Demin Water 3.5 0.216 3.068 36 3

G 24 568.75 568.75 2.41 0.20 0.91 0.22 0.006 A022 M-182, M-166 OPW-005-4" Primary Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Line with Flange 4.5 0.237 4.026 36 3

G 24 568.75 568.75 3.16 0.33 0.91 0.29 0.009 A023 M-182, M-166 OWD-20-6" Waste Disposal Bld to Bld Pen Open Sleeve Class 1 TB Aux Waste Disposal 6.625 0.28 6.065 36 3

G 24 573 573 4.76 0.72 0.91 0.44 0.020 A024 M-182, M-166 OCD-068-18" Condensate Bld to Bld Pen Open Sleeve Class 3 TB Aux Condensate 18 0.562 16.876 36 3

G 24 571 571 13.25 5.30 0.91 1.23 0.150 A025 M-180, M-166, OSW-019-36" Service Water Bld to Bld Pen Open Sleeve Class 3 TB Aux Service Water Supply Header 36 0.75 34.5 36 3

G 23 575 575 27.10 21.21 0.91 2.52 0.600 A027 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 894 74.5 G

10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A028 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 932.04 77.67 G

10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 894 74.5 G

30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 932.04 77.67 G

30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A034 M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 Aux Main Stm See Multiple CTMT to Aux Pens on M-282 and M-662 cover in CTMT Worksheet 14 0.438 13.124 24 2

H 30 571 571 6.87 1.88 0.61 0.64 0.053 P005 M-281, M-661 1-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 34 1.15625 31.6875 48 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P006 M-281, M-661 1-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 34 1.15625 31.6875 48 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P007 M-281, M-661 1-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 35.5 1.1875 33.125 48 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P008 M-281, M-661 1-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Main Steam 35.5 1.1875 33.125 48 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P009 M-281, M-661 1-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 48 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P010 M-281, M-661 1-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 48 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P011 M-281, M-661 1-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 48 4

333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P012 M-281, M-661 1-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Feedwater 16 1.218 13.564 48 4

333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633

Attachment J Turbine Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 111 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P091 M-281, M-661 1-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P092 M-281, M-661 1-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P093 M-281, M-661 1-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P094 M-281, M-661 1-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P095 M-281, M-661 1-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 48 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P096 M-281, M-661 1-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 48 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P097 M-281, M-661 1-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 48 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P098 M-281, M-661 1-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 48 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P112 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 48 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P113 M-282, M-662 1-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 48 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P115 M-282, M-662 1-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P116 M-282, M-662 1-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P117 M-282, M-662 1-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P118 M-282, M-662 1-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P127 M-282, M-662 1-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P128 M-282, M-662 1-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U1 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P205 M-281, M-661 2-MS-001-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 34 1.15625 31.6875 48 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P206 M-281, M-661 2-MS-002-34" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 34 1.15625 31.6875 48 4

213 147 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P207 M-281, M-661 2-MS-003-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 35.5 1.1875 33.125 48 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P208 M-281, M-661 2-MS-004-35 1/2" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Main Steam 35.5 1.1875 33.125 48 4

333 27 579.5 579.5 52.36 54.54 1.22 4.86 1.544 P209 M-281, M-661 2-FW-014-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 48 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P210 M-281, M-661 2-FW-017-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 48 4

213 147 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P211 M-281, M-661 2-FW-011-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 48 4

333 27 584.58 584.58 33.51 22.34 1.22 3.11 0.633 P212 M-281, M-661 2-FW-022-16" Feedwater Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Feedwater 16 1.218 13.564 48 4

333 27 586.83 586.83 33.51 22.34 1.22 3.11 0.633 P291 M-281, M-661 2-BD-007-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.875 0.276 2.323 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P292 M-281, M-661 2-BD-008-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P293 M-281, M-661 2-BD-006-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P294 M-281, M-661 2-BD-005-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.875 0.276 2.323 48 4

213 147 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P295 M-281, M-661 2-BD-007-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1A 2.375 0.218 1.939 48 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P296 M-281, M-661 2-BD-005-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1C 2.375 0.218 1.939 48 4

213 147 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P297 M-281, M-661 2-BD-003-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1D 2.375 0.218 1.939 48 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121 P298 M-281, M-661 2-BD-001-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown Steam Generator 1B 2.375 0.218 1.939 48 4

333 27 580.33 580.33 14.66 4.28 1.22 1.36 0.121

Attachment J Turbine Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 112 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P312 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 48 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P313 M-282, M-662 2-SS-041-3/8" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam Generator Blowdown Sample 0.675 0.065 0.545 48 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P315 M-282, M-662 2-BD-003-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 2.875 0.276 2.323 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P316 M-282, M-662 2-BD-004-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1D) 2.375 0.218 1.939 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P317 M-282, M-662 2-BD-002-2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 2.375 0.218 1.939 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P318 M-282, M-662 2-BD-001-2 1/2" SG Blowdown Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Blowdown (Steam Generator 1B) 2.875 0.276 2.323 48 4

333 27 584.58 584.58 16.76 5.59 1.22 1.56 0.158 P327 M-282, M-662 2-MS-018-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4

213 147 578.08 578.08 16.76 5.59 1.22 1.56 0.158 P328 M-282, M-662 2-MS-017-6" Main Steam Bld to Bld Pen Open Sleeve Class 2 Main Stm U2 CTMT Steam to Aux FW Pumps 6.625 0.432 5.761 48 4

333 27 578.08 578.08 16.76 5.59 1.22 1.56 0.158 T032 M-103 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from Diesel Generator Heat Exchangers 16 0.5 15 2201.625 183.4688 G

31 553.83 567.5 720.48 225.15 55.92 66.93 6.376 T033 M-104 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from to Diesel Generator Heat Exchangers 16 0.5 15 2205 183.75 G

10 553.83 567.5 721.58 225.50 56.01 67.04 6.385 T034a M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Main Stm Blank Sleeve 14 0

14 24 2

H 31 587.75 587.75 7.33 2.14 0.61 0.68 0.061 T034b M-106 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG Main Stm Blank Sleeve 14 0

14 24 2

H 10 587.75 587.75 7.33 2.14 0.61 0.68 0.061 T035 M-106, M-107 0

Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 36 3

J 5

583.5 584.5 7.87 1.64 0.91 0.73 0.047 T036 M-106, M-107 0

Fire Protection Bld to Yard Pen Pipe in Pen Class 3 DG Yard Fire Protection 10.75 0.365 10.02 36 3

J 35 583.5 584.5 7.87 1.64 0.91 0.73 0.047 T068 M-104, M-562 2DO-006-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG Yard Diesel Oil Tank Fill Line length to 588' elevation 4.5 0.237 4.026 48 4

G 5

585.25 593 4.22 0.35 1.22 0.39 0.010 T069 M-104, M-562, M-663 2DO-004-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

18 1.5 G

6 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T070 M-104, M-562, M-663 2DO-001-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

18 1.5 G

7 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T070a M-104 Spare N/A Bld to Bld Pen Open Sleeve Class 3 DG TB Open Sleeve 8

0 0

18 1.5 G

8 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T071 M-103, M-214, M-244 1DO-010-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

18 1.5 G

32 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T072 M-103, M-214, M-244 1DO-003-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

18 1.5 G

33 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T073 M-103, M-214, M-244 1DO-002-4" Diesel Oil Bld to Bld Pen Open Sleeve Class 3 DG TB Diesel Oil 8

0 0

18 1.5 G

34 585.17 585.17 3.14 0.52 0.46 0.29 0.015 T074 M-103, M-214 1DO-001-4" Diesel Oil Bld to Yard Pen Buried Pipe Class 3 DG Yard Diesel Oil see buried pipe 4.5 0.237 4.026 627 52.25 G

35 585.25 593 55.07 4.62 15.93 5.12 0.131 T091 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 10.75 0.365 10.02 60 5

C 16 585 585 13.12 2.74 1.52 1.22 0.078 T092 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 12.75 0.406 11.938 60 5

C 16 586 586 15.63 3.89 1.52 1.45 0.110 T093 M-104, M-106 Det B Spare N/A Bld to Yard Pen Open Sleeve Class 3 TB Yard Spares Blanks Left Intact 14 0.438 13.124 60 5

C 16 585 585 17.18 4.70 1.52 1.60 0.133 T094 M-104 0

Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Fibercast Makeup Demin Waste Discharge 8.625 0.322 7.981 48 4

C 17 586 586 8.36 1.39 1.22 0.78 0.039 T095 M-104, M-105 0

Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Primary Water Storage Tank 6.625 0.28 6.065 1420 118.33 C

18 556.75 556.75 187.89 23.74 36.07 17.46 0.672 T096 M-103 0

Oil Seperator Bld to Yard Pen Pipe in Pen Class 3 TB Yard Oil Seperator Tank 10.75 0.365 10.02 48 4

C 23 586 586 10.49 2.19 1.22 0.97 0.062 T097 M-103 0

Make-Up Demin Bld to Yard Pen Pipe in Pen Class 3 TB Yard Fibercast Makeup Demin Waste Discharge 8.625 0.322 7.981 48 4

C 23 586 586 8.36 1.39 1.22 0.78 0.039 T098 M-103 0

Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Waste Discharge (WD) from Lake Discharge Tank to Discharge Tunnel 6.625 0.28 6.065 48 4

C 24 586 586 6.35 0.80 1.22 0.59 0.023 T099 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 10.75 0.365 10.02 60 5

C 24 585 585 13.12 2.74 1.52 1.22 0.078 T100 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 12.75 0.406 11.938 60 5

C 24 586 586 15.63 3.89 1.52 1.45 0.110 T101 M-103, M-106 Det B Spare N/A Bld to Yard Pen Pipe in Pen Class 3 TB Yard Spares 14 0.438 13.124 60 5

C 24 585 585 17.18 4.70 1.52 1.60 0.133

Attachment J Turbine Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 113 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T102 M-104, M-105 0

Primary Water Bld to Yard Pen Pipe in Pen Class 3 TB Yard Primary Water Supply Header to RCP 6.625 0.28 6.065 940 78.33 C

17 586 586 124.38 15.72 23.88 11.56 0.445 T103 M-105 SH 1 & SH 2, M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate to Alternate Feedwater Pumps-Buried Section 20 0.594 18.812 2712.59 226.05 B

21 586 586 1020.52 367.34 68.90 94.81 10.402 T104 M-104 0

Waste Discharge Bld to Yard Pen Pipe in Pen Class 1 TB Yard Lake Discharge tank 6.625 0.28 6.065 48 4

C 17 586 586 6.35 0.80 1.22 0.59 0.023 T105 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate Pump Recirc 4.5 0.337 3.826 2652.59 221.05 G

22 560 586 6219.50 14.99 67.38 577.81 0.424 T106 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard To condensate transfer and makeup pumps 12.75 0.406 11.938 251.13 20.93 D

22 560 583.25 65.41 16.27 6.38 6.08 0.461

Attachment J Turbine Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 114 of 123 Turbine Building Drains Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T147 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe West Wall 6

0.28 5.44 200 560 557 284.84 32.28 60.96 26.46 0.914 T148 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-1 Equip Drain Sump, 6 pipe North Wall 6

0.28 5.44 100 560 557 142.42 16.14 30.48 13.23 0.457 T149 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB U-2 Equip Drain Sump, 6 pipe West Wall 6

0.28 5.44 200 560 557 284.84 32.28 60.96 26.46 0.914 T150 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump, West-most 6 pipe on North Wall 6

0.28 5.44 100 560 557 142.42 16.14 30.48 13.23 0.457 T151 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Floor Drain Sump East-most 4 pipe on North Wall 4

0.237 3.526 100 560 557 92.31 6.78 30.48 8.58 0.192 T152 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, South-most 4 pipe on West Wall 4

0.237 3.526 150 560 557 138.47 10.17 45.72 12.86 0.288 T153 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, North-most 8 pipe on West Wall 8

0.322 7.356 450 560 557 866.61 132.81 137.16 80.51 3.761 T154 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 8 pipe on North Wall 8

0.322 7.356 450 560 557 866.61 132.81 137.16 80.51 3.761 T155 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, West-most 10 pipe on North Wall 10 0.365 9.27 80 560 557 194.15 37.50 24.38 18.04 1.062 T156 M-103, B-454, B-452, B-471, B-473 Aerated Drain Bld Pen Embedded Pipe Class 3 TB TB Fire Sump, East-most 10 pipe on North Wall 10 0.365 9.27 100 560 557 242.69 46.87 30.48 22.55 1.327

Attachment K Waste Water Treatment Facility Penetrations and Piping TSD # 14-016 Revision 00 Page 115 of 123 Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 W001 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Force Main from Turbine Fire Sump 8.625 0.322 7.981 1

D 2

586.6667 586.6667 2.09 0.35 0.30 0.19 0.010 W002 B-1003, B-1005 Aerated Drain Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Heater bay roof drain lines 6.625 0.28 6.065 1

D 2

585.2 585.2 1.59 0.20 0.30 0.15 0.006 W003 B-1003, B-1005 Sludge Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sludge Line from Outdoor Drying Beds 3.5 0.216 3.068 1

A 6

587 587 0.80 0.05 0.30 0.07 0.001 W004 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTH WWTF Sludge drying bed filtrate 6.625 0.28 6.065 1

A 4

588 588 1.59 0.20 0.30 0.15 0.006 W005 B-1003, B-1005 Water Line Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Water Line from Yard 2.375 0.154 2.067 1

A 3

588 588 0.54 0.02 0.30 0.05 0.001 W006 B-1003, B-1005 Waste Discharge Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Cement Wrapped Ductile Pipe 8.625 0.322 7.981 1

A 2

586.75 586.75 2.09 0.35 0.30 0.19 0.010 W007 B-1003, B-1005 Sanitary Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Sanitary Line 1.9 0.145 1.61 1

A 2

587 587 0.42 0.01 0.30 0.04 0.0004 W008 B-1003, B-1005 Service Air Bld to Yard Pen Pipe in Pen Class 3 WWTF WWTF Service Air Line 1.9 0.145 1.61 1

A 2

586.75 586.75 0.42 0.01 0.30 0.04 0.0004

Attachment L Crib House Penetrations and Piping TSD # 14-016 Revision 00 Page 116 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Sleeve Size inches Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees -

minutes X or Unit 2 Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 C001 M-105 SH 1 & 2, M-271 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Fire Line Below to ForeBay 0

10.75 0.365 10.02 4

AA 111 581.75 581.75 0.87 2.19 1.22 0.08 0.062 C002 M-106, M-272 OSA-002-3" Station Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Station Air 6

3.5 0.216 3.068 4

AA 111 581 581 0.52 0.79 1.22 0.05 0.022 C003 M-106, M-272 0

Control Air Bld to Yard Pen Open Sleeve Class 3 Crib Yard Control Air 6

2.375 0.154 2.067 4

AA 111 581 581 0.52 0.79 1.22 0.05 0.022 C004 M-106, M-272 OHS-020-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Supply 6

3.5 0.216 3.068 4

AA 111 581.5 581.5 0.52 0.79 1.22 0.05 0.022 C005 M-106, M-272 OHS-024-3" Hot Water Bld to Yard Pen Open Sleeve Class 3 Crib Yard 3" Hot Water Return 6

2.375 0.154 2.067 4

AA 111 581.5 581.5 0.52 0.79 1.22 0.05 0.022 C006 M-106, M-272 OMU-031-3" Filtered Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Filtered Water 0

3.5 0.216 3.068 4

AA 111 581.5 581.5 0.27 0.21 1.22 0.02 0.006 C007 M-106, M-272 OFP-011-10" Fire Protection Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Fire Line Below to ForeBay 0

10.75 0.365 10.02 4

AA 111 585.75 585.75 0.87 2.19 1.22 0.08 0.062 C026c M-104 & M-105 sh 1, M-102, M-168 OSW-014-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Service Water Supply Header Crib Pen 0

48 0.625 46.75 4

AA 19 579 579 4.08 47.68 1.22 0.38 1.350 C029c M-104 & M-105 sh 1, M-102, M-168 OSW-013-48" Service Water Bld to Yard Pen Pipe in Pen Class 3 Crib Yard Service Water Supply Header Crib Pen 0

48 0.625 46.75 4

AA 21 579 579 4.08 47.68 1.22 0.38 1.350

Attachment M Fuel Handling Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 117 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A029 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-017-2" Spent Fuel Pool - Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool -

Demin Water 2.375 0.154 2.067 89.58 R

24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 A036 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

24 570 0

415.27 195.73 21.37 38.58 5.543 A037 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 4.05 0.14 2.93 0.38 0.004 A038 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 11.68 0.39 8.44 1.08 0.011 A039 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

24 571 Unknown 7.48 0.25 5.41 0.70 0.007 A040 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R

24 569.33 584 131.25 11.01 37.96 12.19 0.312 A041 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R

24 569.33 583 39.69 1.33 28.70 3.69 0.038 A042 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R

24 570.58 484 34.39 1.48 19.37 3.19 0.042 A043 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R

24 570.58 584 96.00 8.05 27.76 8.92 0.228 A044 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R

24 570.58 584 50.10 2.16 28.22 4.65 0.061 A046 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94 R

24 570.58 584 39.62 1.33 28.65 3.68 0.038 A047 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R

24 569.33 583 67.80 4.33 25.73 6.30 0.123 A048 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86 R

24 569.33 583 46.54 2.00 26.21 4.32 0.057 A049 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R

24 570.58 584 335.99 70.14 39.04 31.21 1.986 A050 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R

24 570.58 584 343.42 71.69 39.90 31.91 2.030 A051 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

16 570 573 415.27 195.73 21.37 38.58 5.543 A052 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 4.05 0.14 2.93 0.38 0.004 A053 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 11.68 0.39 8.44 1.08 0.011 A054 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

16 571 Unknown 7.48 0.25 5.41 0.70 0.007 A055 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R

16 569.33 583 61.28 2.64 34.52 5.69 0.075 A056 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111 R

16 569.33 583 89.16 5.70 33.83 8.28 0.161 A057 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.5 R

16 569.33 583 87.95 5.62 33.38 8.17 0.159 A058 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Decon Pad Drain to Chem Drain Tank 2.375 0.154 2.067 89.75 R

16 569.33 583 48.57 2.09 27.36 4.51 0.059 A059 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R

16 570.58 584 284.84 59.46 33.10 26.46 1.684 A060 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R

16 570.58 584 279.16 58.27 32.44 25.93 1.650 A061 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R

16 569.33 583 103.01 6.58 39.09 9.57 0.186 A062 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R

16 570.58 584 136.67 11.46 39.52 12.70 0.325 A063 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R

16 570.58 583 101.74 6.50 38.61 9.45 0.184 A064 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R

16 570.58 584 79.94 4.11 37.69 7.43 0.116 A065 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R

16 569.33 584 100.13 6.40 38.00 9.30 0.181 A066 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.5 R

16 569.33 583 52.48 1.76 37.95 4.88 0.050

Attachment M Fuel Handling Building Affiliated Penetrations and Piping TSD # 14-016 Revision 00 Page 118 of 123 Pen No.

Drawings U1 Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 P049 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U1 CTMT SFB Fuel Transfer Tube 24 0.688 22.624 8.21 90 270 578.54 578.5417 48.62 22.92 2.50 4.52 0.649 P249 M-281, B-213 Detail 4, M-661 0

Cavity Bld to Bld Pen Pipe in Sleeve Class 1 U2 CTMT SFB Fuel Transfer Tube 24 0.688 22.624 8.21 90 270 578.54 578.5417 48.62 22.92 2.50 4.52 0.649

Attachment N Buried Pipe List TSD # 14-016 Revision 00 Page 119 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A027 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.5 G

10 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A028 M-102, M-168. M-185 OSW-008-12" Service Water to DG Hxs Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water to DG Hxs 12.75 0.406 11.938 77.67 G

10 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A029 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-017-2" Spent Fuel Pool - Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Spent Fuel Pool - Demin Water 2.375 0.154 2.067 89.58 R

24 570.58 583.33 48.48 2.09 27.31 4.50 0.059 A030 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 74.5 G

30 554.75 567.5 232.84 57.91 22.71 21.63 1.640 A031 M-102, M-169 OSW-001-12" Service Water Bld to Bld Pen Buried Pipe Class 3 DG Aux Service Water Supply to Diesel Generator Heat Exchangers 12.75 0.406 11.938 77.67 G

30 553.33 567.5 242.75 60.37 23.67 22.55 1.710 A036 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

24 570 0

415.27 195.73 21.37 38.58 5.543 A037 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 4.05 0.14 2.93 0.38 0.004 A038 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

24 571 Unknown 11.68 0.39 8.44 1.08 0.011 A039 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

24 571 Unknown 7.48 0.25 5.41 0.70 0.007 A040 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 124.52 R

24 569.33 584 131.25 11.01 37.96 12.19 0.312 A041 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SA-014-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 94.17 R

24 569.33 583 39.69 1.33 28.70 3.69 0.038 A042 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K ODW-100-2" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demin Water 2.375 0.154 2.067 63.55 R

24 570.58 484 34.39 1.48 19.37 3.19 0.042 A043 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K OFP-016-4" Fire Protection Bld to Yard Pen Buried Pipe Class 3 Aux SFB Fire Protection 4.5 0.237 4.026 91.08 R

24 570.58 584 96.00 8.05 27.76 8.92 0.228 A044 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SW-181-2" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 2.375 0.154 2.067 92.58 R

24 570.58 584 50.10 2.16 28.22 4.65 0.061 A046 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 01A-004-1 1/2" Instrument Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Instrument Air 1.9 0.145 1.61 94 R

24 570.58 584 39.62 1.33 28.65 3.68 0.038 A047 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 84.42 R

24 569.33 583 67.80 4.33 25.73 6.30 0.123 A048 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 86 R

24 569.33 583 46.54 2.00 26.21 4.32 0.057 A049 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 128.08 R

24 570.58 584 335.99 70.14 39.04 31.21 1.986 A050 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 1CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 130.92 R

24 570.58 584 343.42 71.69 39.90 31.91 2.030 A051 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SI-012-24" Safety Injection Bld to Yard Pen Buried Pipe Unimpacted Aux SFB Safety Injection 24 0.688 22.624 70.11 R

16 570 573 415.27 195.73 21.37 38.58 5.543 A052 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-149-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 4.05 0.14 2.93 0.38 0.004 A053 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-148-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 30.75 R

16 571 Unknown 11.68 0.39 8.44 1.08 0.011 A054 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2AD-147-1 1/2" Spent Fuel Pit Tell Tale Lines Bld to Bld Pen Buried Pipe Class 1 Aux SFB Aerated Drain 1.9 0.145 1.61 17.75 R

16 571 Unknown 7.48 0.25 5.41 0.70 0.007 A055 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-008-2" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 2.375 0.154 2.067 113.25 R

16 569.33 583 61.28 2.64 34.52 5.69 0.075 A056 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SF-022-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 111 R

16 569.33 583 89.16 5.70 33.83 8.28 0.161 A057 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0SF-012-3" Spent Fuel Pool Bld to Yard Pen Buried Pipe Class 1 Aux SFB Spent Fuel Pit Cooling 3.5 0.216 3.068 109.5 R

16 569.33 583 87.95 5.62 33.38 8.17 0.159 A058 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 0CT-061-2" Waste Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Decon Pad Drain to Chem Drain Tank 2.375 0.154 2.067 89.75 R

16 569.33 583 48.57 2.09 27.36 4.51 0.059 A059 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-078-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 108.58 R

16 570.58 584 284.84 59.46 33.10 26.46 1.684 A060 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2CC-080-10" Component Cooling Bld to Yard Pen Buried Pipe Class 2 Aux SFB Component Cooling 10.75 0.365 10.02 106.42 R

16 570.58 584 279.16 58.27 32.44 25.93 1.650 A061 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-008-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 128.25 R

16 569.33 583 103.01 6.58 39.09 9.57 0.186 A062 M-107 Sh 1, 2,3, M-197, M-106 Sect K-K 2AD-146-4" Aerated Drain Bld to Yard Pen Buried Pipe Class 1 Aux SFB Aerated Drain 4.5 0.237 4.026 129.67 R

16 570.58 584 136.67 11.46 39.52 12.70 0.325 A063 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2DW-014-3" Demin Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Demineralized Water 3.5 0.216 3.068 126.67 R

16 570.58 583 101.74 6.50 38.61 9.45 0.184

Attachment N Buried Pipe List TSD # 14-016 Revision 00 Page 120 of 123 Pen No.

Drawings Line Ident No.

System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 A064 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K OWD-059-2 1/2" Waste Disposal Bld to Yard Pen Buried Pipe Class 1 Aux SFB Waste Disposal 2.875 0.203 2.469 123.67 R

16 570.58 584 79.94 4.11 37.69 7.43 0.116 A065 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SW-243-3" Service Water Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Water 3.5 0.216 3.068 124.67 R

16 569.33 584 100.13 6.40 38.00 9.30 0.181 A066 M-107 Sh 1, 2,3, M-260, M-106 Sect K-K 2SA-012-1 1/2" Station Air Bld to Yard Pen Buried Pipe Class 3 Aux SFB Service Air 1.9 0.145 1.61 124.5 R

16 569.33 583 52.48 1.76 37.95 4.88 0.050 C026 M-104 & M-105 sh 1, M-102, M-168 OSW-014-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.5 G

19 549.67 549.6667 174.92 2044.35 52.27 16.25 57.889 C026a M-105 SH 1 & 2, M-272 OSW-014-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

19 579 549.6667 38.08 445.03 11.38 3.54 12.602 C029 M-104 & M-105 sh 1, M-102, M-168 OSW-013-48" Service Water Supply Header Under TB Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header Aux Pen to Under TB 48 0.625 46.75 171.5 G

21 549.67 549.6667 174.92 2044.35 52.27 16.25 57.889 C029a M-105 SH 1 & 2, M-272 OSW-013-48" Service Water Supply Header Bld to Yard Pen Buried Pipe Class 3 Aux Yard Service Water Supply Header at TB Foundation Exit 48 0.625 46.75 37.33 C

21 579 549.6667 38.08 445.03 11.38 3.54 12.602 T032 M-103 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from Diesel Generator Heat Exchangers 16 0.5 15 183.47 G

31 553.83 567.5 720.48 225.15 55.92 66.93 6.376 T033 M-104 & M-106 0

Service Water Bld to Bld Pen Buried Pipe Class 3 TB DG Service Water Return from to Diesel Generator Heat Exchangers 16 0.5 15 183.75 G

10 553.83 567.5 721.58 225.50 56.01 67.04 6.385 T074 M-103, M-214 1DO-001-4" Diesel Oil Bld to Yard Pen Buried Pipe Class 3 DG Yard Diesel Oil see buried pipe 4.5 0.237 4.026 52.25 G

35 585.25 593 55.07 4.62 15.93 5.12 0.131 T103 M-105 SH 1 & SH 2, M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate to Alternate Feedwater Pumps-Buried Section 20 0.594 18.812 226.05 B

21 586 586 1020.52 367.34 68.90 94.81 10.402 T105 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard Condensate Pump Recirc 4.5 0.337 3.826 221.05 G

22 560 586 6219.50 14.99 67.38 577.81 0.424 T106 M-103 0

Condensate Bld to Yard Pen Buried Pipe Class 3 TB Yard To condensate transfer and makeup pumps 12.75 0.406 11.938 20.93 D

22 560 583.25 65.41 16.27 6.38 6.08 0.461 T139 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Forebay Unit 2 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569 569 2978.98 8781.78 24.51 276.76 248.672 T140 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Forebay Unit 2 Circ Water Ice Melting Pipe 96 1

94 25 GG 31 569 569 615.23 1204.82 7.62 57.16 34.117 T141 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Disch Tun Forebay Unit 1 Circ Water Ice Melting Pipe 144 1.25 141.5 80.42 GG 31 569 569 2978.98 8781.78 24.51 276.76 248.672 T142 M-100 0

Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 Disch Tun Forebay Unit 1 Circ Water Ice Melting Pipe 96 1

94 25 GG 31 569 569 615.23 1204.82 7.62 57.16 34.117

Attachment O Circulating Water Intake Inventory List TSD # 14-016 Revision 00 Page 121 of 123 Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T083 M-780, M-100, M-101, M-104 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Blind Flange Man Entry to Circ Water Intake 36 0.375 35.25 9

D 6

564 564 83.06 60.99 2.74 7.72 1.73 T085 M-780, M-100, M-101, M-104 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Blind Flange Man Entry to Circ Water Intake 36 0.375 35.25 9

D 13 564 564 83.06 60.99 2.74 7.72 1.73 T087 M-15, M-100, M-101, B-64, M-103 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Blind Flange Man Enttry to Circ Water Intake 36 0.375 35.25 9

D 27 564 564 83.06 60.99 2.74 7.72 1.73 T088 M-15, M-100, M-101, B-62, M-103 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Blind Flange Man Enttry to Circ Water Intake 36 0.375 35.25 9

D 34 564 564 83.06 60.99 2.74 7.72 1.73 T109 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.5 E

34 564 564 291.38 643.47 3.20 27.07 18.22 T110 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.5 E

34 572 572 291.38 643.47 3.20 27.07 18.22 T111 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 45.625 E

34 564 564 1760.39 5089.54 13.91 163.55 144.12 T111b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 22.5 E

34 564 564 833.50 2457.10 6.86 77.44 69.58 T112 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 144 1.25 141.5 124.2 E

34 564 564 4600.94 13563.19 37.86 427.44 384.07 T113 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water pipe 12' to 17' expansion 174 1.5 171 9

E 34 558 558 402.91 1435.36 2.74 37.43 40.64 T114 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 204 1.5 201 94.67 B

31 558 558 4981.52 20860.11 28.85 462.80 590.69 T115 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 14.25 AA 20 558 558 499.12 1434.84 4.34 46.37 40.63 T116 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 19.5 AA 22 558 558 541.14 1195.02 5.94 50.27 33.84 T117 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 108 1

106 14.25 AA 24 558 558 395.45 873.28 4.34 36.74 24.73 T118 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 114 1

112 8.25 AA 26 558 558 241.90 564.44 2.51 22.47 15.98 T119 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 1 Circ water pipe 120 1

118 14 AA 26 558 558 432.49 1063.21 4.27 40.18 30.11 T120 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2.5 E

26 572 572 291.38 643.47 3.20 27.07 18.22 T121 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 1 Circ water supply pipe to Condenser 108 1

106 2,5 E

26 572 572 291.38 643.47 3.20 27.07 18.22 T122 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 144 1.25 141.5 45.63 E

6 564 564 1760.39 5089.54 13.91 163.55 144.12 T122b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 144 1.25 141.5 83.5 E

6 564 564 1760.39 5089.54 25.45 163.55 144.12 T123 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.5 E

6 572 572 291.38 643.47 3.20 27.07 18.22 T123a M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.5 E

6 572 572 291.38 643.47 3.20 27.07 18.22 T124 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E

6 564 564 1760.39 5089.54 13.91 163.55 144.12 T124b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 22.5 E

6 564 564 1760.39 5089.54 6.86 163.55 144.12 T125 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 12' to 17' expansion 144 1.25 141.5 124.2 E

6 564 564 4600.94 13563.19 37.86 427.44 384.07 T126 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 12' to 17' expansion 174 1.5 171 9

B 8

558 558 402.91 1435.36 2.74 37.43 40.64 T127 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 204 1.5 201 94.67 A

12 558 558 4981.52 20860.11 28.85 462.80 590.69 T128 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 14.25 AA 20 558 558 499.12 1434.84 4.34 46.37 40.63 T129 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 19.5 AA 18 558 558 541.14 1195.02 5.94 50.27 33.84 T130 M-100, M-272 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 108 1

106 14.25 AA 16 558 558 395.45 873.28 4.34 36.74 24.73 T131 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 114 1

112 8.25 AA 14 558 558 241.90 564.44 2.51 22.47 15.98 T132 M-100 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 120 1

118 14 AA 14 558 558 432.49 1063.21 4.27 40.18 30.11 T133 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.5 E

14 572 572 291.38 643.47 3.20 27.07 18.22 T134 M-100 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water supply pipe to Condenser 108 1

106 2.5 E

14 572 572 291.38 643.47 3.20 27.07 18.22 T143 M-100, B-61 Circ Water Intake Bld to Bld Pen Embedded Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 45.63 E

14 564 564 1760.39 5089.54 13.91 163.55 144.12

Attachment O Circulating Water Intake Inventory List TSD # 14-016 Revision 00 Page 122 of 123 Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Y or Unit 1

Azimuth Degrees -

minutes X or Unit 2

Azimuth Degrees -

minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T143b M-100, B-61 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 TB Crib Unit 2 Circ water pipe 144 1.25 141.5 83.5 E

14 564 564 1760.39 5089.54 25.45 163.55 144.12 T144 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 16 558 558 2493.64 9896.63 15.24 231.67 280.24 T145 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 20 558 558 2493.64 9896.63 15.24 231.67 280.24 T146 M-2, B-49 Circ Water Intake Bld to Bld Pen Buried Pipe Class 3 Forebay Lake Circ Water Intake to Forebay 192 0.75 190.5 50 GG 24 558 558 2493.64 9896.63 15.24 231.67 280.24

Attachment P Circulating Water Discharge Pipe Inventory TSD # 14-016 Revision 00 Page 123 of 123 Pen No.

Drawings System Category End Sate MARSSIM Class From To Description Pipe OD inches Wall Thickness Pipe ID inches Length Feet Void Space Volume in3 Y or Unit 1 Azimuth Degrees

-minutes X or Unit 2 Azimuth Degrees

-minutes Elevation End Elevation Interior Surface Area ft2 Void Space Volume ft3 Length meters Int SA m2 Void Space m3 T075 M-104, B-68, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Stand Pipe 48 0.625 46.75 38.60 795132.72 F

9 588 553 472.45 460.15 11.77 43.89 13.03 T076 M-103, B-62, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Stand Pipe 48 0.625 46.75 38.60 795132.72 F

31 588 553 472.45 460.15 11.77 43.89 13.03 T077 M-15, M-101, B-100, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5

977160.98 E

9 562 557 188.50 565.49 1.52 17.51 16.01 T078 M-15, M-101, B-100, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5

977160.98 E

9 562 557 188.50 565.49 1.52 17.51 16.01 T079 B-66, B-68, M-104 Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Service Water Return to Discharge Tunnel 48 0.625 46.75 199.92 4117971.72 E

9 553.83 560 2446.80 2383.09 60.93 227.32 67.48 T080 M-780, M-101, M-103 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5

977160.98 E

31 562 557 188.50 565.49 1.52 17.51 16.01 T081 M-780, M-101, M-103 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circulating Water Discharge from Condenser to Discharge Tunnel 145.5 0.75 144 5

977160.98 E

31 562 557 188.50 565.49 1.52 17.51 16.01 T082 B-62, B-64, M-103 Service Water Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Service Water Return to Discharge Tunnel 48 0.625 46.75 199.92 4117971.72 E

33 553.83 560 2446.80 2383.09 60.93 227.32 67.48 T084 M-780, B-68, B-100, B-68, M-104 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Circ Water Discharge Stand Pipe 36 0.375 35.25 29.5 345470.83 D

9 588 558.5 272.24 199.93 8.99 25.29 5.66 T086 M-15, B-62, B-100, B-66 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Circ Water Discharge Stand Pipe 36 0.375 35.25 29.5 345470.83 D

31 588 558.5 272.24 199.93 8.99 25.29 5.66 T135 M-104, B-68, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U2 Disch Tun Unit 2 Hatch to Discharge Tunnel 36 0.375 35.25 4

46843.50 D

9 562 562 36.91 27.11 1.22 3.43 0.77 T136 M-103, B-62, B-100 Circ Water Discharge Bld to Bld Pen Embedded Pipe Class 3 TB U1 Disch Tun Unit 1 Hatch to Discharge Tunnel 36 0.375 35.25 4

46843.50 D

31 562 562 36.91 27.11 1.22 3.43 0.77 T137 M-1, M-2, B-39, M-100 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U2 Disch Tun Lake Unit 2 Circ Water Discharge Pipe to Lake 168 0.75 166.5 50 13063802.54 GG 9

568.58 568.58 2179.48 7560.07 15.24 202.48 214.08 T138 M-1, M-2, B-39, M-100 Circ Water Discharge Bld to Bld Pen Buried Pipe Class 3 U1 Disch Tun Lake Unit 1 Circ Water Discharge Pipe to Lake 168 0.75 166.5 50 13063802.54 GG 31 568.58 568.58 2179.48 7560.07 15.24 202.48 214.08