Letter Sequence Supplement |
---|
EPID:L-2019-LLA-0231, Rulemaking Package: Certificate of Compliance No. 1032, Amendment 6, Model No. HI-STORM FW (Approved, Closed) |
Results
Other: ML20140A191, ML20182A863, ML20182A864, ML20182A865, ML20182A866, ML20182A870, ML20205L597, ML20315A017, ML20356A328, ML20356A330, ML20356A332, ML20356A336, ML21333A141, ML21333A142, ML21333A143, ML22145A407, ML22290A147, ML23041A466, ML23041A467, ML23041A468, ML23041A469
|
MONTHYEARML20140A1912020-05-19019 May 2020 Application for the Model No. Hi-Storm FW: Storage System, Amendment No. 6 - Supplemental Information Needed Project stage: Other ML20182A8622020-06-30030 June 2020 Responses to HI-STORM FW Amd. 6 Requests for Supplemental Information Project stage: Supplement ML20182A8632020-06-30030 June 2020 Attachment 1: HI-STORM FW Amendment 6 Rsi Responses Project stage: Other ML20182A8642020-06-30030 June 2020 Attachment 2: HI-STORM FW Amendment 6 CoC - RSI-Related Changes Project stage: Other ML20182A8652020-06-30030 June 2020 Attachment 3 - HI-STORM FW Amendment 6 CoC, Appendix a - RSI-Related Changes Project stage: Other ML20182A8662020-06-30030 June 2020 Attachment 4: HI-STORM FW Amendment 6 CoC, Appendix B - RSI-Related Changes Project stage: Other ML20182A8702020-06-30030 June 2020 Attachment 8 - Affidavit Project stage: Other ML20205L5972020-08-10010 August 2020 Transmittal Letter: Application for the Model Hi-Storm FW Storage System, Amendment No. 6 - Accepted for Review Project stage: Other ML20267A1662020-09-24024 September 2020 Transmittal Letter and Rais: Application for the Model No. HI-STORM FW Storage System, Amendment No. 6 - Staggered First Request for Additional Information, Thermal Evaluation Project stage: RAI ML20315A0172020-10-31031 October 2020 Fuelsolutions Spent Fuel Management System Certificate of Compliance Renewal Application Project stage: Other ML20280A7412020-11-0606 November 2020 Transmittal Letter: Application for the Model No. Historm FW, Amendment 6 - Structural and Materials Evaluation, Final Staggered Request for Additional Information Project stage: RAI ML20280A7432020-11-0606 November 2020 Enclosure (Rais) to Transmittal Letter: Application for the Model No. Historm FW, Amendment 6 - Structural and Materials Evaluations, Final Staggered Request for Additional Information Project stage: RAI ML20356A3322020-12-21021 December 2020 Attachment 4 - Acceptance Tests and Maintenance Project stage: Other ML20356A3362020-12-21021 December 2020 Affidavit for Kimberly Manzione Project stage: Other ML20356A3302020-12-21021 December 2020 Attachment 2 - SFSC Heat Removal System Project stage: Other ML20356A3292020-12-21021 December 2020 Attachment 1 - Responses to Request for Additional Information Certificate of Compliance No. 1032 Docket No. 72-1032 HI-STORM FW Storage System Amendment No. 6 Project stage: Response to RAI ML20356A3282020-12-21021 December 2020 International Responses to HI-STORM FW Amd. 6 Requests for Additional Information Project stage: Other ML21146A0962021-07-0202 July 2021 Application for the Westinghouse Sentry Dry Storage Cask System, Certificate of Compliance No. 1026, Amendment No. 5 - Request for Additional Information Project stage: RAI ML21214A1322021-08-0202 August 2021 International, Supplemental Responses to HI-STORM FW Amendment 6 Requests for Additional Information Project stage: Supplement ML21333A1392021-11-29029 November 2021 Attachment 1 - HI-STORM FW Amendment 6 RAI Supplemental Responses Revised November 29, 2021 (Non-Proprietary) Project stage: Supplement ML21333A1382021-11-29029 November 2021 International Revised Supplemental Responses for HI-STORM FW Amd. 6 Requests for Additional Information Project stage: Supplement ML21333A1412021-11-29029 November 2021 Attachment 3 - HI-STORM FW FSAR Proposed Revision 7.D Revised November 29, 2021 (Non-Proprietary) Project stage: Other ML21333A1422021-11-29029 November 2021 Attachment 4 - HI-STORM FW Amendment 6 CoC, Appendix a - Revised November 29, 2021 (Non-Proprietary) Project stage: Other ML21333A1432021-11-29029 November 2021 Attachment 5 - Affidavit of Kimberly Manzione Project stage: Other ML22145A4072022-10-13013 October 2022 User Need Memorandum for Rulemaking for the Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 Project stage: Other ML22145A3132022-10-13013 October 2022, 9 December 2022 Rulemaking Package: Certificate of Compliance No. 1032, Amendment 6, Model No. HI-STORM FW Project stage: Request ML22290A1472022-11-0808 November 2022 Approval of Holtec International Request Withholding Information from Public Disclosure of the Application for Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 (Docket No. 72-1032) Project stage: Other ML22145A4082022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 1: Draft Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4092022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 2: Draft Appendix a, Technical Specifications, Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4102022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 3: Draft Appendix B, Technical Specifications, Approved Contents and Design Features, CoC No.1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4112022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 4: Preliminary Safety Evaluation Report, Certificate of Compliance. No, 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Approval ML23041A4692023-02-15015 February 2023 Enclosure 3 - Final Appendix B, Technical Specifications, Approved Contents and Design Features, CoC No.1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4702023-02-15015 February 2023 Enclosure 4 - Final Safety Evaluation Report, Certificate of Compliance. No, 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Approval ML23041A4682023-02-15015 February 2023 Enclosure 2 - Final Appendix a, Technical Specifications, Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4672023-02-15015 February 2023 Enclosure 1 - Final Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4662023-02-15015 February 2023 Amendment No. 6 to Certificate of Compliance No. 1032 for the Holtec International Storage Module (Hi-Storm) Flood and Wind (FW) Multipurpose Canister (MPC) Storage System (Docket No. 72-1032, CAC No. 001028, EPID: L-2019-LLA-0231) Project stage: Other 2020-09-24
[Table View] |
|
---|
Category:Letter
MONTHYEARML24016A1902024-01-30030 January 2024 International, Inc. - Notice of Violation; the U.S. Nuclear Regulatory Commission Inspection Report 07201014/2022201 ML24018A1992024-01-18018 January 2024 International, Administrative Change to HI-2200343-A ML23361A1622024-01-0404 January 2024 Application for HI-STORM Flood/Wind Multipurpose Storage System, Amendment No. 9 - Acknowledgement of Withdrawal and Notification of the U.S. Nuclear Regulatory Commission Staff Efforts Closure ML23355A0812023-12-21021 December 2023 International - Withdrawal of HI-STORM FW Multipurpose Canister Storage System Amendment 9 ML23321A2462023-11-17017 November 2023 HI-STORM FW Amendment 7 RAI Response Clarifications (Part 3) ML23289A2132023-10-16016 October 2023 International - Schedule for Responses to HI-STORM FW Amendment 9 Requests for Additional Information ML23229A5172023-10-0404 October 2023 Amendment No. 9 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Request for Additional Information ML23271A1662023-09-28028 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) ML23145A1752023-09-12012 September 2023 NRC Choice Letter to Holtec International with Attached Safety Inspection Report, IR 72-1014/2022-201, December 12-15, 2022, Inspection of Holtec International in Camden, New Jersey (Docket Nos.: 72-1014, 72-1032) ML23254A0652023-09-0707 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) ML23254A0012023-09-0505 September 2023 Registration of Use of Casks to Store Spent Fuel ML23227A2492023-08-15015 August 2023 International, HI-STORM FW Amendment 7 RAI 3-10 Response Clarification Call Action Items ML23192A0322023-07-11011 July 2023 International, HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5 ML23188A0532023-07-0707 July 2023 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks NMP2L2846, Nine Mire Point Nuclear Station, Units 1 and 2, General License 30-day Cask Registration Notifications2023-07-0505 July 2023 Nine Mire Point Nuclear Station, Units 1 and 2, General License 30-day Cask Registration Notifications ML23184A1392023-07-0303 July 2023 Registration of Use of Cask to Store Spent Fuel (MPC-295, -296, -297) ML23181A1932023-06-30030 June 2023 International HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Call Action Items ML23163A1782023-06-12012 June 2023 Registration of Use of Cask to Store Spent Fuel (MPC-292, -293, -294) ML23128A3032023-05-0808 May 2023 International - HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 5 ML23096A3012023-04-0606 April 2023 International - Schedule for Responses to HI-STORM FW Amendment 7 Requests for Additional Information Part 5 ML23074A1022023-03-23023 March 2023 Letter, Amendment No. 7 to CoC No. 1032 for the HI-STORM_RAI ML23072A4272023-03-13013 March 2023 International, HI-STORM FW Multipurpose Canister Storage System Amendment 9 Obs Responses ML23041A4662023-02-15015 February 2023 Amendment No. 6 to Certificate of Compliance No. 1032 for the Holtec International Storage Module (Hi-Storm) Flood and Wind (FW) Multipurpose Canister (MPC) Storage System (Docket No. 72-1032, CAC No. 001028, EPID: L-2019-LLA-0231) ML23025A3712023-02-10010 February 2023 Acceptance Review of Request for Amendment 9 to Certificate of Compliance No. 1032 for HI-STORM Flood/Wind Multipurpose Canister Storage System ML22300A1512023-02-0303 February 2023 Congressional Letters - Holtec International HI-STORM Flood - Wind Multipurpose Canister Storage System, Certificate of Compliance No. 1032, Amendment No.6 ML23006A2642023-01-0606 January 2023 International HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 4 L-22-263, Spent Fuel Storage Cask Registration2022-12-12012 December 2022 Spent Fuel Storage Cask Registration ML22326A3612022-12-0707 December 2022 Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Request for Additional Information Batch 4 Letter ML22336A1332022-12-0101 December 2022 HI-STORM FW Amendment 7 RAI 5-2 Response Clarification PLA-8036, Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-80362022-11-30030 November 2022 Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-8036 PLA-8035, Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-80352022-11-0808 November 2022 Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-8035 ML22290A1472022-11-0808 November 2022 Approval of Holtec International Request Withholding Information from Public Disclosure of the Application for Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 (Docket No. 72-1032) ML22276A2822022-10-0303 October 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 3 ML22265A1732022-09-22022 September 2022 Registration of Use of Casks to Store Spent Fuel ML22258A2512022-09-15015 September 2022 International, HI-STORM FW Amendment 7 RAI Responses Part 1 Clarification Call Action Items ML22242A2202022-09-0606 September 2022 Amendment No. 8 to Certificate of Compliance No. 1032 for the HI-STORM FW System Transmittal Letter ML22216A0782022-08-0404 August 2022 Request for Exemption from Various 10 CFR Part 72 Regulations Resulting from Non-Destruction-Examination Compliance ML22210A1462022-07-29029 July 2022 HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 2 ML22206A1772022-07-25025 July 2022 Registration of Use of Cask to Store Spent Fuel (MPC-240, -241, -242, -243) ML22199A3052022-07-18018 July 2022 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask ML22194A9542022-07-13013 July 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 1 - Additional Supporting Documents ML22192A2162022-07-11011 July 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part I ML22189A0382022-07-0808 July 2022 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks ML22172A1932022-06-30030 June 2022 Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Request for Additional Information Batch 2 ML22180A1392022-06-29029 June 2022 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks ML22175A1092022-06-24024 June 2022 Registration of Use of Cask to Store Spent Fuel (MPC-211, -212, -213) NOC-AE-220038, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2022-06-23023 June 2022 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask NMP1L3465, Independent Spent Fuel Storage Installation - General License 30-day Cask Registration Notifications2022-06-17017 June 2022 Independent Spent Fuel Storage Installation - General License 30-day Cask Registration Notifications ML22157A4702022-06-0606 June 2022 Registration of Use of Cask to Store Spent Fuel (MPC-0208, -209, -210) ML22151A1822022-05-31031 May 2022 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report 2024-01-04
[Table view] |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 November 29, 2021 Norma Garcia Santos - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 EPID L-2019-LLA-0231
Subject:
Revised Supplemental Responses to HI-STORM FW Amd. 6 Requests for Additional Information Reference(s):
[1] NRC Letter, Application for the Model No. HI-STORM FW Storage System, Amendment No. 6 - Staggered First Request for Additional Information, from Norma Garcia Santos (NRC) to Christopher OMullane (Holtec), dated September 24, 2020.
[2] NRC Letter, Application for the Model No. HI-STORM FW Storage System, Amendment No. 6 - Final Staggered Request for Additional Information, from Norma Garcia Santos (NRC) to Christopher OMullane (Holtec), dated November 6, 2020.
[3] Holtec Letter 5018081, Holtec Responses to HI-STORM FW Amd. 6 Requests for Additional Information, from Christopher OMullane (Holtec) to Norma Garcia Santos (NRC), dated December 21, 2020.
[4] NRC Conversation Record, Conference Call with Holtec International--Clarify Thermal, Materials, and Structural RAI Responses Regarding HISTORM FW, Amendment 6 (Docket No. 72-1032), dated March 8, 2021.
Document ID 5018092 Page 1 of 3
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
[5] NRC Conversation Record, Conference Call with Holtec International--
Discuss response to Structural RAI 3-3 Regarding HISTORM FW, Amendment 6 (Docket No. 72-1032), dated March 24, 2021.
[6] Holtec Letter 5018089, Supplemental Responses to HI-STORM FW Amd. 6 Requests for Additional Information, from Christopher OMullane (Holtec) to Norma Garcia Santos (NRC), dated August 2, 2021.
Dear Ms. Garcia Santos:
By letters dated September 24, 2020 [1] and November 6, 2020 [2], the NRC staff sent staggered Requests for Additional Information (RAIs) needed to complete their detailed technical review of Amendment 6 of the HI-STORM FW Certificate of Compliance (CoC) 72-1032. Holtec provided responses to the RAIs by letter dated December 21, 2020 [3]. Subsequent to submittal of these responses, Holtec and the NRC staff participated in two telephone conference calls on March 8, 2021 [4] and March 24, 2021 [5], during which it was determined that clarification was warranted for Holtecs responses to Thermal RAIs 4-1 & 4-2, Materials RAI 4-1, and Structural RAIs 3-1, 3-2, & 3-3. Holtec provided supplemental responses to these RAIs by letter dated August 2, 2021
[6]. Following submittal of the supplemental responses, further discussion between Holtec and the NRC staff regarding Thermal RAIs 4-1 & 4-2 and Structural RAIs 3-1, 3-2, & 3-3 determined additional clarification was necessary. Holtec is pleased to submit its revised supplemental responses in Attachment 1 of this letter.
Attachments 2 & 3 contain the proprietary and non-proprietary versions of the HI-STORM FW FSAR with changes specifically resulting from the latest revisions of the supplemental responses.
Note that any previous changes associated with Amendment 6 remain tracked in Attachments 2 &
3, while only the latest changes are highlighted for clarity. contains Appendix A of CoC 72-1032 with changes specifically resulting from the latest revisions of the supplemental responses. Note that any previous changes associated with Amendment 6 remain tracked in Attachment 4, while only the latest changes are highlighted for clarity.
As Attachment 2 is considered proprietary, an affidavit requesting that this information be withheld from public disclosure in accordance with 10CFR2.390 is contained in Attachment 5.
Document ID 5018092 Page 2 of 3
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 If you have any questions, please contact me at c.omullane@holtec.com or 856-912-1162.
Sincerely, Christopher OMullane Licensing Engineer, Holtec International cc:(via email)
Yoira Diaz-Sanabria (USNRC)
Kimberly Manzione (Holtec)
Attachments : HI-STORM FW Amendment 6 RAI Supplemental Responses Revised November 29, 2021 (NON-PROPRIETARY) : HI-STORM FW FSAR Proposed Revision 7.D Revised November 29, 2021 (PROPRIETARY) : HI-STORM FW FSAR Proposed Revision 7.D Revised November 29, 2021 (NON-PROPRIETARY) : HI-STORM FW Amendment 6 CoC, Appendix A - Revised November 29, 2021 (NON-PROPRIETARY) : Affidavit in Accordance with 10CFR2.390 Document ID 5018092 Page 3 of 3