Other: ML20140A191, ML20182A863, ML20182A864, ML20182A865, ML20182A866, ML20182A870, ML20205L597, ML20315A017, ML20356A328, ML20356A330, ML20356A332, ML20356A336, ML21333A141, ML21333A142, ML21333A143, ML22145A407, ML22290A147, ML23041A466, ML23041A467, ML23041A468, ML23041A469
|
MONTHYEARML20140A1912020-05-19019 May 2020 Application for the Model No. Hi-Storm FW: Storage System, Amendment No. 6 - Supplemental Information Needed Project stage: Other ML20182A8622020-06-30030 June 2020 Responses to HI-STORM FW Amd. 6 Requests for Supplemental Information Project stage: Supplement ML20182A8632020-06-30030 June 2020 Attachment 1: HI-STORM FW Amendment 6 Rsi Responses Project stage: Other ML20182A8642020-06-30030 June 2020 Attachment 2: HI-STORM FW Amendment 6 CoC - RSI-Related Changes Project stage: Other ML20182A8652020-06-30030 June 2020 Attachment 3 - HI-STORM FW Amendment 6 CoC, Appendix a - RSI-Related Changes Project stage: Other ML20182A8662020-06-30030 June 2020 Attachment 4: HI-STORM FW Amendment 6 CoC, Appendix B - RSI-Related Changes Project stage: Other ML20182A8702020-06-30030 June 2020 Attachment 8 - Affidavit Project stage: Other ML20205L5972020-08-10010 August 2020 Transmittal Letter: Application for the Model Hi-Storm FW Storage System, Amendment No. 6 - Accepted for Review Project stage: Other ML20267A1662020-09-24024 September 2020 Transmittal Letter and Rais: Application for the Model No. HI-STORM FW Storage System, Amendment No. 6 - Staggered First Request for Additional Information, Thermal Evaluation Project stage: RAI ML20315A0172020-10-31031 October 2020 Fuelsolutions Spent Fuel Management System Certificate of Compliance Renewal Application Project stage: Other ML20280A7412020-11-0606 November 2020 Transmittal Letter: Application for the Model No. Historm FW, Amendment 6 - Structural and Materials Evaluation, Final Staggered Request for Additional Information Project stage: RAI ML20280A7432020-11-0606 November 2020 Enclosure (Rais) to Transmittal Letter: Application for the Model No. Historm FW, Amendment 6 - Structural and Materials Evaluations, Final Staggered Request for Additional Information Project stage: RAI ML20356A3322020-12-21021 December 2020 Attachment 4 - Acceptance Tests and Maintenance Project stage: Other ML20356A3362020-12-21021 December 2020 Affidavit for Kimberly Manzione Project stage: Other ML20356A3302020-12-21021 December 2020 Attachment 2 - SFSC Heat Removal System Project stage: Other ML20356A3292020-12-21021 December 2020 Attachment 1 - Responses to Request for Additional Information Certificate of Compliance No. 1032 Docket No. 72-1032 HI-STORM FW Storage System Amendment No. 6 Project stage: Response to RAI ML20356A3282020-12-21021 December 2020 International Responses to HI-STORM FW Amd. 6 Requests for Additional Information Project stage: Other ML21146A0962021-07-0202 July 2021 Application for the Westinghouse Sentry Dry Storage Cask System, Certificate of Compliance No. 1026, Amendment No. 5 - Request for Additional Information Project stage: RAI ML21214A1322021-08-0202 August 2021 International, Supplemental Responses to HI-STORM FW Amendment 6 Requests for Additional Information Project stage: Supplement ML21333A1392021-11-29029 November 2021 Attachment 1 - HI-STORM FW Amendment 6 RAI Supplemental Responses Revised November 29, 2021 (Non-Proprietary) Project stage: Supplement ML21333A1382021-11-29029 November 2021 International Revised Supplemental Responses for HI-STORM FW Amd. 6 Requests for Additional Information Project stage: Supplement ML21333A1412021-11-29029 November 2021 Attachment 3 - HI-STORM FW FSAR Proposed Revision 7.D Revised November 29, 2021 (Non-Proprietary) Project stage: Other ML21333A1422021-11-29029 November 2021 Attachment 4 - HI-STORM FW Amendment 6 CoC, Appendix a - Revised November 29, 2021 (Non-Proprietary) Project stage: Other ML21333A1432021-11-29029 November 2021 Attachment 5 - Affidavit of Kimberly Manzione Project stage: Other ML22145A4072022-10-13013 October 2022 User Need Memorandum for Rulemaking for the Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 Project stage: Other ML22145A3132022-10-13013 October 2022, 9 December 2022 Rulemaking Package: Certificate of Compliance No. 1032, Amendment 6, Model No. HI-STORM FW Project stage: Request ML22290A1472022-11-0808 November 2022 Approval of Holtec International Request Withholding Information from Public Disclosure of the Application for Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 (Docket No. 72-1032) Project stage: Other ML22145A4082022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 1: Draft Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4092022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 2: Draft Appendix a, Technical Specifications, Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4102022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 3: Draft Appendix B, Technical Specifications, Approved Contents and Design Features, CoC No.1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Draft Other ML22145A4112022-12-0909 December 2022 Rulemaking Memorandum, Enclosure 4: Preliminary Safety Evaluation Report, Certificate of Compliance. No, 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Approval ML23041A4692023-02-15015 February 2023 Enclosure 3 - Final Appendix B, Technical Specifications, Approved Contents and Design Features, CoC No.1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4702023-02-15015 February 2023 Enclosure 4 - Final Safety Evaluation Report, Certificate of Compliance. No, 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Approval ML23041A4682023-02-15015 February 2023 Enclosure 2 - Final Appendix a, Technical Specifications, Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4672023-02-15015 February 2023 Enclosure 1 - Final Certificate of Compliance No. 1032, Amendment No. 6, HI-STORM Flood/Wind Multipurpose Canister Storage System Project stage: Other ML23041A4662023-02-15015 February 2023 Amendment No. 6 to Certificate of Compliance No. 1032 for the Holtec International Storage Module (Hi-Storm) Flood and Wind (FW) Multipurpose Canister (MPC) Storage System (Docket No. 72-1032, CAC No. 001028, EPID: L-2019-LLA-0231) Project stage: Other 2020-09-24
[Table View] |
|
---|
Category:Letter
MONTHYEARML24016A1902024-01-30030 January 2024 International, Inc. - Notice of Violation; the U.S. Nuclear Regulatory Commission Inspection Report 07201014/2022201 ML24018A1992024-01-18018 January 2024 International, Administrative Change to HI-2200343-A ML23361A1622024-01-0404 January 2024 Application for HI-STORM Flood/Wind Multipurpose Storage System, Amendment No. 9 - Acknowledgement of Withdrawal and Notification of the U.S. Nuclear Regulatory Commission Staff Efforts Closure ML23355A0812023-12-21021 December 2023 International - Withdrawal of HI-STORM FW Multipurpose Canister Storage System Amendment 9 ML23321A2462023-11-17017 November 2023 HI-STORM FW Amendment 7 RAI Response Clarifications (Part 3) ML23289A2132023-10-16016 October 2023 International - Schedule for Responses to HI-STORM FW Amendment 9 Requests for Additional Information ML23229A5172023-10-0404 October 2023 Amendment No. 9 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System - Request for Additional Information ML23271A1662023-09-28028 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) ML23145A1752023-09-12012 September 2023 NRC Choice Letter to Holtec International with Attached Safety Inspection Report, IR 72-1014/2022-201, December 12-15, 2022, Inspection of Holtec International in Camden, New Jersey (Docket Nos.: 72-1014, 72-1032) ML23254A0652023-09-0707 September 2023 Registration of Spent Fuel Storage Cask Pursuant to 10 CFR 72.212(b)(2) ML23254A0012023-09-0505 September 2023 Registration of Use of Casks to Store Spent Fuel ML23227A2492023-08-15015 August 2023 International, HI-STORM FW Amendment 7 RAI 3-10 Response Clarification Call Action Items ML23192A0322023-07-11011 July 2023 International, HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Corrected Attachments 4 and 5 ML23188A0532023-07-0707 July 2023 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks NMP2L2846, Nine Mire Point Nuclear Station, Units 1 and 2, General License 30-day Cask Registration Notifications2023-07-0505 July 2023 Nine Mire Point Nuclear Station, Units 1 and 2, General License 30-day Cask Registration Notifications ML23184A1392023-07-0303 July 2023 Registration of Use of Cask to Store Spent Fuel (MPC-295, -296, -297) ML23181A1932023-06-30030 June 2023 International HI-STORM FW Amendment 7 RAI Responses Part 5 Clarification Call Action Items ML23163A1782023-06-12012 June 2023 Registration of Use of Cask to Store Spent Fuel (MPC-292, -293, -294) ML23128A3032023-05-0808 May 2023 International - HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 5 ML23096A3012023-04-0606 April 2023 International - Schedule for Responses to HI-STORM FW Amendment 7 Requests for Additional Information Part 5 ML23074A1022023-03-23023 March 2023 Letter, Amendment No. 7 to CoC No. 1032 for the HI-STORM_RAI ML23072A4272023-03-13013 March 2023 International, HI-STORM FW Multipurpose Canister Storage System Amendment 9 Obs Responses ML23041A4662023-02-15015 February 2023 Amendment No. 6 to Certificate of Compliance No. 1032 for the Holtec International Storage Module (Hi-Storm) Flood and Wind (FW) Multipurpose Canister (MPC) Storage System (Docket No. 72-1032, CAC No. 001028, EPID: L-2019-LLA-0231) ML23025A3712023-02-10010 February 2023 Acceptance Review of Request for Amendment 9 to Certificate of Compliance No. 1032 for HI-STORM Flood/Wind Multipurpose Canister Storage System ML22300A1512023-02-0303 February 2023 Congressional Letters - Holtec International HI-STORM Flood - Wind Multipurpose Canister Storage System, Certificate of Compliance No. 1032, Amendment No.6 ML23006A2642023-01-0606 January 2023 International HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 4 L-22-263, Spent Fuel Storage Cask Registration2022-12-12012 December 2022 Spent Fuel Storage Cask Registration ML22326A3612022-12-0707 December 2022 Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Request for Additional Information Batch 4 Letter ML22336A1332022-12-0101 December 2022 HI-STORM FW Amendment 7 RAI 5-2 Response Clarification PLA-8036, Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-80362022-11-30030 November 2022 Registration for the Use of Spent Fuel Storage Casks 203, 202, and 204, PLA-8036 PLA-8035, Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-80352022-11-0808 November 2022 Registration for the Use of Spent Fuel Storage Casks 205, 200, and 201, PLA-8035 ML22290A1472022-11-0808 November 2022 Approval of Holtec International Request Withholding Information from Public Disclosure of the Application for Holtec HI-STORM Flood/Wind Multipurpose Canister Storage System, Amendment No. 6 (Docket No. 72-1032) ML22276A2822022-10-0303 October 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 3 ML22265A1732022-09-22022 September 2022 Registration of Use of Casks to Store Spent Fuel ML22258A2512022-09-15015 September 2022 International, HI-STORM FW Amendment 7 RAI Responses Part 1 Clarification Call Action Items ML22242A2202022-09-0606 September 2022 Amendment No. 8 to Certificate of Compliance No. 1032 for the HI-STORM FW System Transmittal Letter ML22216A0782022-08-0404 August 2022 Request for Exemption from Various 10 CFR Part 72 Regulations Resulting from Non-Destruction-Examination Compliance ML22210A1462022-07-29029 July 2022 HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 2 ML22206A1772022-07-25025 July 2022 Registration of Use of Cask to Store Spent Fuel (MPC-240, -241, -242, -243) ML22199A3052022-07-18018 July 2022 Independent Spent Fuel Storage Installation, Registration of Dry Spent Fuel Storage Cask ML22194A9542022-07-13013 July 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part 1 - Additional Supporting Documents ML22192A2162022-07-11011 July 2022 International, HI-STORM FW Amendment 7 Responses to Requests for Additional Information Part I ML22189A0382022-07-0808 July 2022 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks ML22172A1932022-06-30030 June 2022 Amendment No. 7 to Certificate of Compliance No. 1032 for the HI-STORM Flood/Wind Multipurpose Canister Storage System Request for Additional Information Batch 2 ML22180A1392022-06-29029 June 2022 Registration of Use of Independent Spent Fuel Storage Installation (ISFSI) Casks ML22175A1092022-06-24024 June 2022 Registration of Use of Cask to Store Spent Fuel (MPC-211, -212, -213) NOC-AE-220038, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2022-06-23023 June 2022 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask NMP1L3465, Independent Spent Fuel Storage Installation - General License 30-day Cask Registration Notifications2022-06-17017 June 2022 Independent Spent Fuel Storage Installation - General License 30-day Cask Registration Notifications ML22157A4702022-06-0606 June 2022 Registration of Use of Cask to Store Spent Fuel (MPC-0208, -209, -210) ML22151A1822022-05-31031 May 2022 Independent Spent Fuel Storage Installation Annual Radioactive Effluent Release Report 2024-01-04
[Table view] |
Text
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 June 30, 2020 Norma Garcia Santos - Project Manager Storage and Transportation Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No. 72-1032, Certificate of Compliance (CoC) No. 1032 EPID L-2019-LLA-0231
Subject:
Holtec Responses to HI-STORM FW Amd. 6 Requests for Supplemental Information Reference(s): [1] Holtec Letter 5018071, HI-STORM FW Amendment 6 (1032-6), from Christopher OMullane (Holtec) to Michael Layton (NRC), dated October 2, 2019.
[2] NRC Letter, Application for the Model No. HI-STORM FW Storage System Amendment No. 6 - Supplemental Information Needed, from Norma Garcia Santos (NRC) to Christopher OMullane (Holtec), dated May 19, 2020.
[3] Holtec Letter 5018077, Schedule for Responses to HI-STORM FW Amd. 6 Requests for Supplemental Information, from Christopher OMullane (Holtec) to Norma Garcia-Santos (NRC), dated June 2, 2020.
Dear Ms. Garcia Santos:
By letter dated October 2, 2019 [1], Holtec submitted a request to amend Certificate of Compliance (CoC) 72-1032 for the HI-STORM FW MPC Storage System. Subsequently, the NRC staff sent Requests for Supplemental Information (RSIs) by letter dated May 19, 2020 [2].
Holtec is pleased to submit responses to NRC RSIs in Attachment 1 to this letter. Attachments 2 through 4 contain the RSI-related changes to the CoC and its appendices, while Attachments 5 &
6 contain the RSI-related changes to the proprietary and non-proprietary versions of the HI-STORM FW FSAR, respectively. Note that all previous changes associated with Amendment 6 Document ID 5018078 Page 1 of 2
Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 remain tracked, while changes specifically resulting from RSIs are highlighted for clarity. contains the proprietary structural reference generated in response to RSI-St-1 &
RSI-St-2.
As Attachments 5 & 7 are considered proprietary, an affidavit requesting that this information be withheld from public disclosure in accordance with 10CFR2.390 is contained in Attachment 8.
If you have any questions please contact me at c.omullane@holtec.com or 856-912-1162.
Sincerely, Christopher OMullane Licensing Engineer, Holtec International cc:(via email)
John McKirgan (USNRC)
Kimberly Manzione (Holtec)
Attachments : HI-STORM FW Amendment 6 RSI Responses : HI-STORM FW Amendment 6 CoC - RSI-Related Changes : HI HI-STORM FW Amendment 6 CoC, Appendix A - RSI-Related Changes : HI-STORM FW Amendment 6 CoC, Appendix B - RSI-Related Changes : HI-STORM FW FSAR Proposed Revision 7.A (PROPRIETARY) : HI-STORM FW FSAR Proposed Revision 7.A (NON-PROPRIETARY) : Holtec Report HI-2200647R0 (PROPRIETARY) : Affidavit in Accordance with 10CFR2.390 Document ID 5018078 Page 2 of 2