PNO-IV-87-043, on 870903,fire Occurred in Auxiliary Transformer & Switchgear Room 13.8 Kv Busing.Investigation Underway to Determine Cause of Electrical Fault & Resulting Fire

From kanterella
(Redirected from ML20235C531)
Jump to navigation Jump to search
PNO-IV-87-043:on 870903,fire Occurred in Auxiliary Transformer & Switchgear Room 13.8 Kv Busing.Investigation Underway to Determine Cause of Electrical Fault & Resulting Fire
ML20235C531
Person / Time
Site: South Texas STP Nuclear Operating Company icon.png
Issue date: 09/04/1987
From: Constable G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
References
PNO-IV-87-043, PNO-IV-87-43, NUDOCS 8709240481
Download: ML20235C531 (2)


t I, . September 4,1987 l PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE -- PNO-IV-87-43 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region IV staff on this date.

FACILITY: Houston Lighting & Power Licensee Emergency Classification:

South Texas Project, Unit 1 Notification of Unusual Event Bay City, Texas Alert DN: 50-498 Site Area Emergency General Emergency X Not Applicable

SUBJECT:

FIRE IN AUXILIARY TRANSFORMER At 5:48 p.m. (CDT) on September 3, 1987, a fire occurred in the STP, Unit 1 auxiliary transformer (UAT) and switchgear room 13.8 KV busing. The fire started when the UAT was being returned to service following an electrical outage. The operators observed a breaker trip and smoke from the VAT was reported shortly thereafter. The deluge system was activated and the site fire brigade responded and declared the fire out at 5:55 p.m. Damage appears to be extensive, but localized to the busing between the UAT and the 13.8 KV switchgear room. No personnel injuries occurred. The licensee was completing reactor vessel head installation following initial fuel loading when the fire occurred.

The licensee is investigating to determine the cause of the electrical fault and resulting fire.

The licensee issued a press release to local media shortly after the event occurred.

I The NRC does not plan to issue a press release.

The state of Texas has been informed.

Region IV received notification of this occurrence by telecon from the SRI at ,

6:30 p.m. on September 3, 1987. Region IV has informed NRR.

This information has been confirmed with a licensee representative.

CONTACT: G. L. Constable, FTS 728-8151 l

l transmitted via 5520 D: RA LJCallan:cs RDMartin SEP -4 1987 9/4/87 9/4/87 g j t' c

b 70904 ,

87092404B1 9 '

h1 7-043 PDR

)

/, DISTRIBUTION:

MAIL:

i H. St. MNBB E/W Willste XDKiDMB (Original)

! Chainnan Zech ED0 OIA ' NMSS DOT:(Trans only) i

'Com. Bernthal PA AE0D RES i Com. Roberts OGC VIB FAX:

Com. Carr MPA OE TTWO ACRS NSAC SECY GPA (Air CA Phillips Rights)

PDR NRR RRI DCS NRC OC LICENSE F Regional Offices (Reactor Licensee) l l

1 I

1

(

i i

1 l

I l

l i

l I

}

l l

l i

1 i

L-__-_-___ -_ _ ]